You are on page 1of 10

16

Technical
information

Ti

Ti 16-10 06 09 en-GB

Issue 2, 2010-07-09

Products affected in Series


Truck

Bus

Engine (I&M)

P93

P96

E2011

Miscellaneous:

Information about the vision and lighting control unit


(CUV)
Changes

Bus

The following changes have been made in this


issue:
Chassis serial number for Buses, Scania Latin America has been added.
The tables on pages 6, 8 and 10 have been
changed.

Background
Scania has optimised the hardware in the vision
and lighting control unit for the functionality ordered. This will affect bodybuilders who use the
functions for spotlights, working lights, front/
rear foglights and direction indicators for trailers.

Scania Sdertlje

1 870 289

Scania Latin America

3 665 633

Service Solution
Changes are made in the CUV control unit's
functionality. The tables below show how the
new outputs for the outputs compare with previously.
The control unit's part number can be read directly on the control unit's label or under the
product information tab in SDP3 (Scania Diagnosis and Programmer).

Production Solution
This modification was introduced into production from the following chassis numbers:
Truck

Scania Sdertlje

2 054 883

Scania Zwolle

5 241 367

Scania Angers

9 149 475

Scania Latin America

3 664 411

Scania CV AB 2010-08

1 (10)

2 (10)

Scania CV AB 2010-08

Ti 16-10 06 09 Issue 2, 2010-07-09

None3

2025651

Reduced output on CUV output: from 200W to 2x70 W excl. 1 relay.


Reduced output on CUV output: from 200W to 1x70 W.
3
The CUV control unit does not have drivers for the function.

2025652
2025653

None3
None3

Reduced output1
Pin 6 in C489
None3
None3

None3
None3

2025649
2025650

2025648

Reduced output1
Pin 6 in C489
Reduced output
Pin 6 in C489
None3
None3

Spotlights
bumper

Reduced output1
Pin 5 in C489
None3

Spotlights sun
visor

2025647

Part

Trucks

Reduced output1
Reduced output1

Reduced output1
With
With

With

With
With

None3

Reduced output1
Reduced output1
None3

With

Foglights rear

Reduced output1

Foglights front

Functionality CUV

None3
Reduced output2
Pin 7 in C489
Reduced output2
Pin 7 in C489
None3
None3

Reduced output2
Pin 7 in C489
None3

Working lights

None3
None3

With

None3
With

With

With

Trailer direction
indicators

Buses
Part

2025648
2025649
2025651
2025652
2025653

Spotlights

Functionality CUV
Foglights front

Reduced output
None2
Reduced output1
None2
None2

Reduced output
Reduced output1
Reduced output1
Reduced output1
Reduced output1

Foglights rear

None2
With
With
With
With

Reduced output on CUV output: from 200W to 2x70 W


excl. 1 relay.
2
The CUV control unit does not have drivers for the
function.

Ti 16-10 06 09 Issue 2, 2010-07-09

Scania CV AB 2010-08

3 (10)

Relay solutions
Parts information
The necessary materials and tools are available
at Scania's dealers. For other output and installation instructions, see the section Installation
instructions on the bodywork website.
IMPORTANT!

All connected electrical circuits must be protected with fuses.


There are 3 relay solutions on the following
pages for spotlight activation and working
lights:
The relay solution for the activation of Spotlights in the sun visor applies for CUVs with
the part numbers:
2 025 648
2 025 649

2 025 650
2 025 651

2 025 652
2 025 653

The relay solution for the activation of Spotlights in the bumper applies for CUV part
numbers:
2 025 649
2 025 653

2 025 650

2 025 652

The relay solution for the activation of the


Working lights applies for CUV part numbers:
2 025 648
2 025 653

2 025 649

2 025 652

IMPORTANT!

If more than 18 A is needed from fuse 30 in the


central electric unit then a separate cable is routed from the Battery connection for bodybuilding, see the section Installation instructions on
the bodywork website.

4 (10)

Scania CV AB 2010-08

Ti 16-10 06 09 Issue 2, 2010-07-09

Spotlights in the sun visor


Relay solution for spotlights in the sun visor

Pos

Part

1
2
3

Fuse
Cable
Power relay

4
5
6

Cable
Spotlights
Cable

7
8
9

Cable
Switch
Cable

Note

Fuse 30 in the central electric unit.


Cable area 6 mm.
Fitted in the central electric unit. May be loaded with max. 40 A, 30
A resistive load + 10 A lamp load. Only lamp load max. 18 A continuously.
Cable area 6 mm.
Spotlights sun visor. Max. 430W incl. lower spotlights.
Fitted by bodybuilder. Connect with ring cable terminal to G10.
Cable area 6 mm.
Fitted by bodybuilder. Cable area min. 0.75 mm.
See Switch on the next page.
Fitted by bodybuilder. Cable area min. 0.75 mm. Connect on CUV
B4 or C1-21.

Ti 16-10 06 09 Issue 2, 2010-07-09

Scania CV AB 2010-08

5 (10)

Switch
Designation

Part

Switch
Cable terminal, 0.5-1.0 mm2
Cable terminal, 1.1-2.5 mm2
Pin

1 539 080
1 443 343
1 443 344

Function

Signal type

Source/destination

1
3

Supply voltage for symbol lighting.


Supply voltage +24V

Voltage
Voltage

4
5
7
9

Ground for acknowledgement lamp


Not used
Output signal to lamp
Supply voltage for acknowledgement
lamp
Grounding the switch lighting

Ground

C274, C275 or C276


Control unit (E32), connected
with pin 9
G1, connected with pin 10.

Voltage
Voltage

Power relay
Connected with pin 3

Ground

G1, connected with pin 4

10

6 (10)

Scania CV AB 2010-08

Ti 16-10 06 09 Issue 2, 2010-07-09

Spotlights in the bumper


Relay solution for spotlights in the bumper

Pos

Part

1
2
3

Fuse
Cable
Power relay

4
5
6

Cable
Spotlights
Cable

7
8
9

Cable
Switch
Cable

Note

Fuse 30 in the central electric unit.


Cable area 6 mm.
Fitted in the central electric unit. May be loaded with max. 40 A, 30
A resistive load + 10 A lamp load. Only lamp load max. 18 A continuously.
Cable area 6 mm.
Spotlights bumper. Max. 430W incl. upper spotlights.
Fitted by bodybuilder. Connect with ring cable terminal to G14/
G15. Cable area 6 mm.
Fitted by bodybuilder. Cable area min. 0.75 mm.
See Switch on the next page.
Fitted by bodybuilder. Cable area min. 0.75 mm. Connect on CUV
B4 or C1-21.

Ti 16-10 06 09 Issue 2, 2010-07-09

Scania CV AB 2010-08

7 (10)

Switch
Designation

Part

Switch
Symbol (ordered from Scania)
Cable terminal, 0.5-1.0 mm2
Cable terminal, 1.1-2.5 mm2

1 519 363
234
1 443 343
1 443 344

Pin

Function

1
3

Supply voltage for symbol lighting.


Supply voltage +24V

Voltage
Voltage

4
5
7
9

Ground for acknowledgement lamp


Not used
Output signal to lamp
Supply voltage for acknowledgement
lamp
Grounding the switch lighting

Ground

C274, C275 or C276


Control unit (E32), connected
with pin 9
G1, connected with pin 10.

Voltage
Voltage

Power relay
Connected with pin 3

Ground

G1, connected with pin 4

10

8 (10)

Signal type

Scania CV AB 2010-08

Source/destination

Ti 16-10 06 09 Issue 2, 2010-07-09

Working lights
Relay solution for working lights

Pos

Part

1
2
3
4

Fuse
Cable
Cable
Bulb

Cable

6
7

Cable
Power relay

8
9
10

Cable
Switch
Cable

Note

Fuse 39 in the central electric unit.


Cable area at least 2.5 mm.
Cable area at least 2.5 mm.
Working lights, the total output for connected headlamps must not
exceed 360 W.
Fitted by bodybuilder. Connect with ring cable terminal to G8.
Cable area min. 2.5 mm.
Fitted by bodybuilder. Cable area min. 0.75 mm.
Fitted in the central electric unit. May be loaded with max. 40 A, 30
A resistive load + 10 A lamp load. Only lamp load max. 18 A continuously.
Fitted by bodybuilder. Cable area min. 0.75 mm.
Part number 1 534 818.
Fitted by bodybuilder. Cable area min. 0.75 mm. Signal from F7 in
the central electric unit.

Ti 16-10 06 09 Issue 2, 2010-07-09

Scania CV AB 2010-08

9 (10)

Switch
Designation

Part

Switch
Symbol (ordered from Scania)
Cable terminal, 0.5-1.0 mm2
Cable terminal, 1.1-2.5 mm2

1 519 363
10
1 443 343
1 443 344

Pin

Function

1
3

Supply voltage for symbol lighting.


Supply voltage +24V

Voltage
Voltage

4
5
7
9

Ground for acknowledgement lamp


Not used
Output signal to lamp
Supply voltage for acknowledgement
lamp
Grounding the switch lighting

Ground

C274, C275 or C276


Signal from pin F7 in the central electric unit, connected with
pin 9
G1, connected with pin 10

Voltage
Voltage

Power relay
Connected with pin 3

Ground

G1, connected with pin 4

10

Signal type

Source/destination

Parts
Designation

Switch

10 (10)

Part

Quantity

1 746 407

1 per function

Scania CV AB 2010-08

Ti 16-10 06 09 Issue 2, 2010-07-09