You are on page 1of 4

Date:

Lab. Report No
Sheet No.

REPORT ON CONCRETE STRENGTH - CHB


(ASTM C 140)
PROJECT: ASEZA PHASE - 1 SAMPLED BY: EBTCI
LOCATION: Casiguran, Aurora SAMPLED BY:
CONTRACTOR: NEW KANLAON CONSTRUCTION INC. DATE SAMPLED: -
SAMPLE DESCRIPTION: Concrete Hallow Blocks ( 4" thick ) DATE TESTED: September 8, 2
PART OF STRUCTURE Barrier Wall / Load Bearing CHB TESTED BY: J.C. Condrado
QUANITITY REPRESENTED: 10,000 pcs

ULTIMATE LOAD COMPRESSIVE


H (cm) Ws (g) Wi (g) Net Volume (cc) Net Area(cm2) (KN) STRENGTH (Mpa)
Specimen No.
(1) (2) (3) (4)=(2)-(3) (5)=(4)/(1) (6) (7)=(6)/(5) x 10

Calculation ( ASTM C 140 sec. 9.4)


(5) An (net area) = ( Vn / H ) (7) Compressive Strength = Pmax / An
(4) Vn (net volume) = ( Ws - Wi ) ( 1 g/cc ) (6) Pmax = Maximum Compressive Load
(3) Wi = Immersed Weight of Specimen
(2) Ws = Saturated Weight of Specimen
(1) Height of the Specimen
Test Witnessed by;

Authorize Representative
Findings/Observations:

CHECKED BY: CERTIFIED BY:

Laboratory Technician
Lab. Report No. AB - CHB - 001
Sheet No. 1 of 1

ETE STRENGTH - CHB


M C 140)
EBTCI

-
September 8, 2010
J.C. Condrado / M.J. Tolentino

Specs
Requirements Remarks

6.9 Mpa

6.9 Mpa

6.9 Mpa
Laboratory Technician

You might also like