You are on page 1of 2

Page 1

Flow Meter Site Investigation


Project: Location: Date/Time: Crew:
Omaha FM 3-4-10 / 14:40 ABM - WRS
MH#: Pipe Shape: Pipe Material: Pipe Size (in):
0653039 Rectangular Concrete 156 x 167
Site ID: Address: Site Quality: Basin:
13 1716 South 52nd St. Good

Location Map Planar Description

Summary Description:

Site Hazards Measurements Site Conditions


Heavy Traffic? Moderate Manhole Depth (ft): 19.64 Surcharge Evidence? No
Needed Traffic Attendants: 0 Manhole Dia. (in): 3 Depth of Surcharge (ft): 0
H2S: 0 O2: 20.8 MH Cover Size (in): 26 Depth of Debris (in): 0
LEL: 0 CO: 0 MH Cover Type: Vented pick Usable MH Steps? No
Describe potential hazards: Measured Flow Depth (in): 7 Meter: ADFM
Velocity (fps): 3 Cellular Signal Strength:
Normal Hazards
Mounting Band Description: Antennae Install Considerations:

Half band mount Vented MH Cover

Other Comments: Permanent Power Available?

No
Page 2

Installation Sketch & Notes Pipe Cross Section

Depth (in) Width (in) Depth (in) Width (in)


156 167
155 168
154 168

SURFACE DOWN

INFLOW OUTFLOW

You might also like