You are on page 1of 3

ISO/TC 28/SC 2

Measurement of petroleum and related products

Secretary: Paula Watkins, American Petroleum Institute, 1220 L Street NW, Washington, DC 20005, USA
Tel: +1 202 682 8197 Fax: +1 202 962 4797 E-Mail: watkinsp@api.org

ISO/TC 28/SC 2 N 539


2009-02-10

Report of ISO/TC 28/SC 2/WG 9 Tank calibration, to ISO/TC 28/SC 2 for


plenary meeting, 17 February 2009, London
Attached is the report provided the Convenor, Srini Sivaraman, which will be discussed under agenda
item 6.4 at the forthcoming ISO/TC 28/SC 2 plenary meeting to be held on 17 February 2009 in
London.

Yours sincerely

Paula Watkins

Paula Watkins
Secretary to ISO/TC 28/SC 2
ISO TC 28/SC2/WG9: Report

ISO 7507 -4 Document - Revision and ballot comments- resolution completed. Document forwarded for
processing toward publication.

New work proposal has been submitted for approval in revising tank calibration standards on Horizontal Tanks
(12917 Parts 1 and 2) to include uncertainty analysis

Subject to approval of the new work items, next meeting is likely to be held in Vienna, Austria some time in
September 2009

Srini Sivaraman
February 10, 2009

2
Summary of the status of the ISO/TC 28/SC 2/WG 9 standards

ISO Status Related Title Additional comments


Year of API
publication MPMS
(confirmation) Chapter
4269 IS/01 (06) 2555 Petroleum and liquid petroleum products First edition published on 2001-03-15.
– Tank calibration by liquid Due for ISO systematic review in 2011.
measurement – Incremental method
using volumetric meters
7507-1 IS/03 2.2A Petroleum and liquid petroleum products Second edition published on 2003-12-15.
– Calibration of vertical cylindrical tanks Under systematic review (ballot initiated
– Part 1: Strapping method on 2008-10-15 and terminates on 2009-
03-16).
7507-2 IS/05 (08) 2.2B Petroleum and liquid petroleum products Second edition published on 2005-06-01.
– Calibration of vertical cylindrical tanks Confirmed following systematic review in
– Part 2: Optical-reference-line method 2008. Due for next ISO systematic review
in 2013.
7507-3 IS/06 2.2C Petroleum and liquid petroleum products Second edition published on 2006-07-15.
– Calibration of vertical cylindrical tanks Due for ISO systematic review in 2009.
– Part 3: Optical-triangulation method
7507-4 IS/95 2.2D Petroleum and liquid petroleum products First edition published on 1995-07-15.
DIS/08 – Calibration of vertical cylindrical tanks Under revision following ISO systematic
– Part 4: Internal electro-optical distance review in 2005. DIS ballot terminated on
ranging method 2008-07-21. 0 negative votes. Comments
resolved by WG and final text under
preparation.
7507-5 IS/00 (08) – Petroleum and liquid petroleum products First edition published on 2000-07-01.
– Calibration of vertical cylindrical tanks Originally agreed to be revised following
– Part 5: External electro-optical distance systematic review in 2005, but listed as a
ranging method PWI while other projects were completed.
In 2008 WG recommended that a revision
was not progressed, and the standard was
listed as confirmed instead. Due for next
ISO systematic review in 2013.
7507-6 TR/97 – Petroleum and liquid petroleum products Published as a type 2 TR on 1997-11-01.
– Calibration of vertical cylindrical tanks TR withdrawn when incorporated as
– Part 6: Recommendations for Annex B of ISO 7507-1:2003.
monitoring, checking and verification of
tank calibration and capacity table
12917-1 IS/02 (07) 2551 Petroleum and liquid petroleum products First edition published on 2002-07-01.
2.2E – Calibration of horizontal cylindrical Corrected and reprinted 2002-09-15.
tanks – Part 1: Manual methods Confirmed following systematic review in
2007 (SC 2 Res. 7/2007 – N501) but WG
requested to review comments in order to
consider initiating a revision as other
priorities allow. WG 9 developing an NP
to propose revision.
12917-2 IS/02 (08) 2.2F Petroleum and liquid petroleum products First edition published on 2002-09-15.
– Calibration of horizontal cylindrical Confirmed following systematic review in
tanks – Part 2: Internal electro-optical 2008. Due for next ISO systematic review
distance-ranging method in 2013. WG 9 developing an NP to
propose revision.
16662 NP/97 – Petroleum and liquid petroleum products NP (28/SC 3 N 696) results reviewed by
– Tank calibration methods – AG (see 28/AG N 203). WG 1 invited to
Uncertainty analysis prepare a WD (Res. 7 of 28/AG N 206).
However, SC 3/WG 1 decided on an
alternative approach to include an annex
on uncertainty analysis in ISO 7507 Parts
1-3.