You are on page 1of 4

Ashok Leyland

5.7l 6 Cylinder 120 kW Inline BS III


Pressure Drop vs. Flow estimation

Amit Arora
Rohit Kataria
System Data & Model Assumptions
Exhaust System Configuration
• DOC –7.50”Dia x 7.0”L, 300/8

Data Requested:
• Pressure drop vs. Flow

Model based Assumptions


• Flow range: As per customer details
• Temperature: As per customer details
• Atmospheric Pressure: 1.0bar
• DOC coating levels used: 0.0mil

Environmental Technologies Proprietary Information –provided under NDA - Corning Proprietary 2


Results- Pressure Drop @ Diff. Flow rates- DOC
DOC- Rd. 7.50”x 7.0”L, 300 cpsi/ 8.0mil

35

30
Pressuredrop [mbar]

25

20

15

10

0
300 400 500 600 700 800 900 Assumption:
Atmospheric pressure- 1.0 bar
M ass Flow Rate [kg/h] Washcoat loading thickness –0.0 mil

S No Diameter Length Cell density Wall Washcoat Mass flow Temperature


p total
[inch]: [inch]: [cpsi]: thickness Load [g/l] rate [kg/h]: [ºC]:
[mbar]
(flat) [mil]:
1080 7.70 7.00 300 8.0 0 331 535 12.28
1350 7.50 7.00 300 8.0 0 405 515 14.47
1500 7.50 7.00 300 8.0 0 515 489 17.52
1900 7.50 7.00 300 8.0 0 700 493 23.24
2200 7.50 7.00 300 8.0 0 806 501 28.58
2400 7.50 7.00 300 8.0 0 877 510 31.82

Environmental Technologies Proprietary Information –provided under NDA - Corning Proprietary 3


Thank You

Environmental Technologies Proprietary Information –provided under NDA - Corning Proprietary 4