THE WOODSTONE

PLANS
THE WOODSTONE

CONSTRUCTION DOCUMENTATION

BUILDING INFORMATION MODELING

SCALE: SEE VIEW SHEET NUMBER


Chief Architect Sample Plan
Chief Architect, Inc. PRESENTATION Aug 1, 2006
6500 N. Mineral Dr. Coeur d'Alene, ID. 83815
800-482-4433 www.chiefarchitect.com WOODSTONE VIEWS DRAWN BY: A.F.
OWNER & BUILDER'S NOTE GENERAL NOTES

SHEET NUMBER
125.'
THESE PLANS SHALL NOT BE USED FOR CONSTRUCTION UNTIL STAMPED AND SIGNED BY AN ENGINEER AND APPROVED BY N90°E
THE LOCAL BUILDING DEPARTMENT. THE BUILDER IS EXPECTED TO FOLLOW THESE PLANS, APPLICABLE BUILDING CODES ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES.
AND LOCAL ORDINANCES. HE SHALL VERITY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING
WORK. WHILE THESE PLANS ARE DRAWN TO SHOW THE PROPOSED WORK AS ACCURATELY AS POSSIBLE, SCHEMATIC PROPERTY LINE
FOUNDATION AND TRUSS DESIGN SHALL BE VERIFIED BY A QUALIFIED ENGINEER FOR COMPLIANCE WITH SITE REQUIREMENTS.
DETAILS MAY BE USED IN SOME CASES FOR CLARITY. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE

30'
SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. DIMENSIONS AND NOTES SHALL TAKE PRECEDENCE OVER THE SCALING OF DRAWINGS.

WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. WALL DIMENSIONS ARE TO THE EXTERIOR OF FRAMING UNLESS NOTED OTHERWISE.
THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE
LUMBER COMING IN CONTACT WITH CONCRETE OR MASONRY SHALL BE TREATED TO A MINIMUM OF 40.CCA. ALL LUMBER IN

SCALE: SEE VIEW


DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE

DRAWN BY: A.F.


INTENT OF THE PLANS OR NOTES. CONTINUOUS CONTACT WITH THE GROUND SHALL BE TREATED TO A MINIMUM OF .60 CCA.

Aug 1, 2006
THE ENGINEER/DESIGNER ASSUMES NO RESPONSIBILITY FOR SCHEDULING, FABRICATION, CONSTRUCTION TECHNIQUES OR ALL FRAMING LUMBER TO BE #2 OR BETTER DF OR EQUIVALENT, UNLESS NOTED OTHERWISE.
MATERIALS, OR QUANTITIES USED IN THE WORK. THE ENGINEER/ DESIGNER ASSUMES NO RESPONSIBILITY FOR FIELD SET BACK LINE
CHANGES, SITE VARIANCES OR DISCREPANCIES NOT BROUGHT TO HIS/HER ATTENTION FOR CLARIFICATION. EXTERIOR AND INTERIOR MATERIALS AND FINISHES TO BE DETERMINED BY OWNER.

BUILDING PERFORMANCE
THE INFORMATION SHOWN ON THIS
SITE PLAN WAS PROVIDED BY THE HEAT LOSS CALCULATIONS SHALL COMPLY WITH THE REQUIREMENTS OF REGIONAL AND LOCAL CODES. SEE CALCULATIONS.
OWNER. FIELD SURVEY OR
VERIFICATION WAS NOT MADE. PORCHES AND GARAGE AREAS NOT INCLUDED IN LIVING AREA.

ALL EXHAUST FANS TO BE VENTED DIRECTLY TO THE EXTERIOR.

GENERAL NOTES
OWNER:
ADVANCED RELATIONAL TECHNOLOGY ALL PENETRATIONS OF THE BUILDING ENVELOPE SHALL BE SEALED WITH CAULK OR FOAM.
6500 N. MINERAL DRIVE 15'
COEUR D'ALENE, ID. 83815 ALL COMBUSTION APPLIANCES WILL BE VENTED DIRECTLY TO THE EXTERIOR.

PLOT PLAN
PROJECT ADDRESS: FURNACE FIREBOX SHALL HAVE OUTSIDE COMBUSTION AIR SUPPLY PURSUANT TO REGIONAL AND LOCAL CODES.
NEW RESIDENCE 15'

BUILDING AREA:
JURISDICTION KOOTENAI COUNTY FIRST FLOOR: 2780 SQ. FT.
SECOND FLOOR: 634 SQ. FT.
ZONING: R3 RPD. (RESIDENTIAL PLANNED DEVELOPMENT) GARAGE: 922 SQ. FT.
PATIO

APN: 00000-00000-00000
ATTIC ACCESS SHALL BE:
SITE AREA 123-456 A MINIMUM OF 22" X 36". THERE SHALL BE 30" MIN. CLEARANCE AT OR ABOVE THE OPENING.

8"E
237.72'
N7° 40' 4
PERMIT #: 1234567890 LOCATED IN A CORRIDOR, HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. ATTICS WITH A MAXIMUM VERTICAL
HEIGHT OF LESS THAN 30" WILL NOT REQUIRE ACCESS OPENINGS.
FIRE DISTRICT KOOTENAI COUNTY
VENTILATION
WATER IDW
ATTIC SHALL HAVE VENTILATION EQUAL TO 1 SQ. FOOT PER 150 SQ. FEET OF ATTIC SPACE. VENTILATION SHALL BE PROTECTED
FROM SNOW AND RAIN AND SHALL BE COVERED WITH GALVANIZED WIRE SCREEN. OPENINGS SHALL BE LOCATED TO PROVIDE
SEWAGE DISPOSAL
CROSS VENTILATION.
CITY SEWER

' 31"W
'
291.38
GARAGES SHALL BE VENTED WITH 60 SQUARE INCHES LOCATED 6" ABOVE THE FLOOR SURFACE.

S9° 42
PROPOSED STRUCTURE
UNDER FLOOR SPACES SHALL HAVE VENTILATION EQUAL TO ONE SQ. FOOT PER 150 SQ. FEET OF FLOOR SPACE. VENTS SHALL BE
SOIL PARAMETERS:
CAST INTO THE CONCRETE STEM WALLS AND COVERED WITH GALVANIZED WIRE SCREEN. VENTS SHALL BE LOCATED TO PROVIDE

Chief Architect Sample Plan


BASED ON SOILS INDIGENOUS TO THE AREA:
CROSS VENTILATION.
BEARING PRESSURE - 1000 PSI
LATERAL ACTIVE PRESSURE 35 PSF FLUID EQUIVALENT
SOIL-CONCRETE COEFFICIENT 0.35 RAILING NOTES:

WOODSTONE
SOIL PROFILE SD

w/W
STAIRWAYS SHALL HAVE A MIN. WIDTH OF 34". HAND RAILS MAY ENCROACH A MAX. OF 3 1/2" INTO THE REQUIRED WIDTH.

w/W
LATERAL DESIGN

w/W
TREADS SHALL HAVE A MIN. WIDTH OF 9". STAIR TREADS MUST BE UNIFORM AND CAN NOT VARY FROM THE LARGEST TO THE
WIND: 80 MPH BASIC WIND SPEED

w/W
SMALLEST BY MORE THAN 3/8".
SEISMIC: ZONE 3

w/W
EXPOSURE "B" CONCRETE
STAIRWAYS SHALL HAVE MIN. 6'-8" OF HEADROOM AT THE NOSE OF THE STAIR.

w/W
DRIVEWAY

w/W
ENCLOSED USABLE SPACE UNDER INTERIOR STAIRS SHALL BE PROTECTED ON THE ENCLOSED FACE WITH 5/8" TYPE "X" GYPSUM

w/W
WALL BOARD.

w/W
w/W
STAIRWAYS SHALL HAVE AT LEAST ONE HANDRAIL LOCATED 34" TO 38" ABOVE THE NOSING OF TREADS AND LANDINGS. THE

w/
W
30'

C/

w/
HAND GRIP PORTION OF HANDRAILS SHALL NOT BE LESS THAN 1-1/2" OR GREATER THAN 2" IN CROSS-SECTIONAL DIMENSION.

W
W
EXTERIOR FINISH NOTES
C/

w/
W
W
C/

w/
W
W

HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS. THE ENDS OF HANDRAILS SHALL RETURN TO WALL OR
EXTERIOR FINISH TO BE SIDING OVER 5/8 CDX PLYWOOD/OSB. MATERIAL AND COLOR BY
C

w/
/W

TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL.


OWNER.
C/

w/
W
W
C/

w/
W
W

STAIRWAYS HAVING LESS THAN 2 RISERS DO NOT REQUIRE A HAND RAIL.


C/

w/

ROOFING TO BE LIGHT WEIGHT TILE OVER 30# FELT, 5/8 CDX PLYWOOD/OSB.
W
W

WATER
C/

w/

SEWER
W
W

34" MIN. HEIGHT GUARDRAILS SHALL BE PROVIDED FOR AT PORCHES, DECKS, BALCONIES, STAIRWAYS AND LANDINGS WHERE
C/

w/
W
W

CHIMNEY HEIGHT SHALL BE DETERMINED USING A 10' RADIUS PLANE AND SHALL BE 2' HIGHER
THE ADJACENT SURFACE IS GREATER THAN 24" BELOW.
C/

w/
W
W

THAN ANY ROOF SURFACE 10' FROM THE CHIMNEY. WALK WAY
50'

C/

w/
W
W

RAILING AND GUARDRAIL BALUSTER SPACING SHALL BE NO GREATER THAN 4".


C/

w/
W
W

DOWNSPOUTS TO BE COLLECTED AND ROOF RUN OFF TO BE DIRECTED AWAY FROM


C/

w/
W
W

STRUCTURE.
THE TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF GUARDRAIL SHALL NOT ALLOW A 6" DIAMETER
C/

w/
W
W

6500 N. Mineral Dr. Coeur d'Alene, ID. 83815


www.chiefarchitect.com
SPHERE TO PASS THROUGH.
C/

w/
W
W

FINISH GRADE SHALL SLOPE AWAY FROM STRUCTURE MIN. 1/2" PER FOOT OF RUN FOR 4' MIN. POWER
C/

w/
W
W

30'

CABLE
GENERAL FIRE ASSEMBLY NOTES:
C/

w/
W
W

PHONE
C/

w/

WINDOWS AND GLAZING


W
W

METALLIC OUTLET BOXES ARE PERMITTED TO BE INSTALLED PROVIDED THE SURFACE AREA OF INDIVIDUAL BOXES DOES NOT
C/

w/
W
W

Chief Architect, Inc.


C/

w/

WINDOWS SHALL BE DUAL PANE WITH WOOD FRAMES (MIN U VALUE OF 0.6). EXCEED 100 SQ. INCHES IN ANY 100 SQ. FEET. BOXES LOCATED ON OPPOSITE SIDES OF WALLS OR PARTITIONS SHALL BE
W
W

w/

SEPARATED BY A MIN. HORIZONTAL DISTANCE OF 24". APPROVED NONMETALLIC OUTLET BOXES SHALL BE PERMITTED ONLY AS
W

MANUFACTURER AND COLOR TO BE DETERMINED BY OWNER.


ALLOWED BY LOCAL CODE.
119
EVERY BEDROOM SHALL BE PROVIDED WITH AN EGRESS WINDOW WITH FINISH SILL .45
r=9 '
HEIGHT NOT GREATER THAN 44" ABOVE THE FINISH FLOOR HEIGHT AND SHALL HAVE A 40. WATER RESISTANT GYPSUM BACKING BOARD MAY BE INSTALLED OVER OR AS PART OF THE FIRE RESISTANCE RATED SYSTEM IN
89'
MINIMUM OPENABLE AREA OF 5.7 SQ. FT. EGRESS WINDOWS SHALL NOT HAVE AN SHOWER AND TUB AREAS TO RECEIVE CERAMIC OR PLASTIC WALL TILE OR PLASTIC FINISHED WALL PANELS. THE GYPSUM BOARD
OPENABLE AREA LESS THAN 20" WIDE OR 24" HIGH. RATING SHALL BE BROUGHT DOWN TO THE FLOOR BEHIND THE FIXTURES.

SAFETY GLAZING SHALL BE PROVIDED WHERE GLASS IS TO BE USED IN DOORS, MINERAL FIBER OR GLASS FIBER INSULATION OF A THICKNESS NOT EXCEEDING THAT OF THE STUD DEPTH MAY BE ADDED WITHIN
THE STUD CAVITY WITHOUT DEGRADING THE FIRE RESISTANCE RATING.

800-482-4433
WITHIN A 24" ARC OF DOORS AND WHERE THE BOTTOM EDGE IS WITHIN 18" ABOVE WATER
THE FLOOR.
ALL PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE OF NON-COMBUSTIBLE MATERIAL THAT EXTENDS AT LEAST 6" FROM THE
SAFETY GLAZING SHALL BE PROVIDED IN DOORS AND ENCLOSURES FOR HOT TUBS,
WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS.
WOODSTONE FACE OF THE ASSEMBLY. THE MEMBRANES ON EACH SIDE OF THE ASSEMBLY AND THE FULL THICKNESS OF THE PENETRATION
SHALL BE SEALED WITH A FIRE RESISTIVE SEALANT SO THAT HOT GASSES CANNOT PASS THROUGH. IN THE EVENT OF A CENTRAL
VACUUM SYSTEM THE PIPE SHALL BE METALLIC FROM THE MACHINE THROUGH THE DRYWALL. SEAL AROUND THE PIPE
ALL EXTERIOR DOORS AND WINDOWS SHALL BE FINISHED WITH WEATHER RESISTANT
COATINGS AND WEATHERSTRIPPED.
DRIVE PENETRATION.

DOORS
PLOT PLAN
DOORS BETWEEN GARAGE AND LIVING AREA SHALL BE 1-3/4" TIGHT FITTING SOLID CORE DOORS WITH A RATING OF 60 MINUTES.
SCALE: 1" = 15' DOOR SHALL BE SELF CLOSING.

EXTERIOR EXIT DOORS WILL BE 36" MIN. NET CLEAR DOOR WAY SHALL BE 32" MIN. DOOR SHALL BE OPENABLE FROM INSIDE
WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. GLAZING IN DOORS SHALL BE DUAL PANE SAFETY
GLASS WITH MIN. U-VALUE OF 0.60. PERIMETER OF DOOR SHALL BE WEATHER STIRPPED.

INTERIOR DOORS TO BE SOLID CORE. STYLE AND FINISH BY OWNER.

GARAGE DOORS TO BE SECTIONAL, OVERHEAD DOORS, MATERIALS AND FINISH TO BE DETERMINED BY OWNER.
SHEET NUMBER
PATIO B
11

11'2 2'4 3' 1'8 3'8 1'8 14'6 23'4 1/2 18'7 1/2

9' 2'2 1'10 1'10 5'10 4'8 4' 5'7 5'6 5'6 6'9 1/2 5'7 3/4 3'8 3'8 5'7 3/4

SCALE: SEE VIEW

DRAWN BY: A.F.


2840 FIXED

Aug 1, 2006
90" TOP HT. ROOF

16 0" T
O H
OPENINGS

"T S

40 O
9
P
90 40

SH P
16
2050 5050 2050

1'8
4050 FIXED 4050 FIXED CASEMENT FIXED CASEMENT
CANTILEVER ROOF TRUSSES OVER PATIO

3650 DOUBLE
CASEMENT 8' CEILING HEIGHT AT PERIMETER
NOOK

4'9 1/2
D/W TEMP GLASS TEMP GLASS

3068
3068
DOOR EGRESS

4'6
8:12 SLOPE UP

6'

6'
DOOR

CLOSET
6068
9'
2'X4' VELUX FLAT 9'1" CEILING FORMED
SKYLIGHTS FLAT 9' CEILING BY BOTTOM CHORD OF TRUSSES
IN CENTER OF MASTER BEDROOM

2'2
8:12 SLOPE UP
A

(3) 2019 FIXED


CASEMENT EGRESS

8:12 SLOPE UP
A

13'8 3/4
14'
(3) 5068 SINGLE HUNG M BDRM

ENTERTAINMENT
4050 DOUBLE
D B
BDRM 2 96" TOP HEIGHT 9
BEDROOM MASTER BDRM

4'6 1/4
D B

CABINETS

2'2
9 A
ISLAND 24" HIGH TEMP LOWER VENT

Breakfast Bar
C

3'6
KITCHEN

5'
C
D B

FLOOR PLANS
9

20'
C
FIREPLACE TO CEILING 8' CEILING HEIGHT AT PERIMETER
DBL. D.V. THROUGH CHASE
2' OVEN 5'6 KITCHEN

5'
OUT ROOF 8:12 SLOPE UP

4'2 1/2
2'6
SLOPE UP HARDWOOD GAS FP
SLOPE UP CROWN MOLDING

26
HARDWOOD

68
2868 2868 2868
PANTRY RIDGE LINE OF VAULT

11168
ENTERTAINMENT
SCISSORS TRUSS CEILING RIDGE

2'5 1/2
2468
3'6
Carpet

3'
2'9
50 CFM
BONUS ROOM FLOOR PLAN
REFRIG.
FAMILY

CABINETS
Walk-in

TEMP GLASS
A Shower
A
GREATFAMILY
ROOM 5468

4016 XO
1/4" = 1' Tile 50 CFM

7'
3' D B
BATH 2 9 3'
D
9
B
BATH 3'2 4'8 6'2 Tile
C Tile

38'
Carpet HARDWOOD

3'6
C
GABLES AT EACH END OF VAULT Tile
SHOWER OVER TUB 1'1 1/2 3'6 3'8 4'2 8' 11'10 20'4 6' 2'4
2'8 1/4 2668

7'8 1/4
Buffet
ON FIRST FLOOR
2868 2868
70610

5'1 1/2
LINEN

3'6
UP

4068
A 24X32

4046 GLASS BLOCK


CARPET 2'X4' VELUX
Carpet Tile SLOPE UP CRAWL
CROWN MOLDING

2668
OPEN RAIL Above
BATH 3
SPACE SKYLIGHT
ACCESS Counter
D B 8' CEILING HEIGHT SLOPE UP A JETTED TUB
9 Vanity

5'

7'
Cabinet

5'4
2'
BATH C MASTER 9
BATH
M BATH
D B
(15)10" TREADS HARDWOOD 3080

CASEMENT EGRESS

3'6
(16)7-9/16" RISERS 9'1" CEILING Plant Shelf Over
GLASS C
A HEIGHT Linen Cabinet

4050 DOUBLE
DOOR

2'
2'4

70610
BDRM 3 Tile A CARPET
PLANT SHELF

D B 2668
9 Ironing 10'6
LINEN
13'

Tile Board A ENTRY


BEDROOM

2'5 1/2
D B
C Cabinet 9
OPEN BELOW

2868
A DINING
STORAGE D B C

56610
9
DINING

CLOSET
UNDER A
LAUNDRY
D B

6'8 3/8
STAIRS 9 C
HARDWOOD

Chief Architect Sample Plan


8'

OFFICE

6068
50 CFM 13'1 D B CARPET
9
LAUNDRY
7'8 1/2
C
See thru OFFICE

SHELF & POLE


Cabinets A
Nat'l Gas WASHER CROWN 9'1" CEILING Gas FP C A
Above,

SHELF & POLE


or Electric

14'8
21' Dryer Shelf, MOLDING HEIGHT
LIVING

WOODSTONE
3080 ENTRY DOOR

11'
DN D B CROWN MOLDING CLOSET
2'4 1/2
6'3 5/8
7'3 13/16 5' Base
Cabinet & (2) 1080 SIDELIGHTS LIVING 9 D
9
B

C
8'9 1/2
FLAT 9'1" CEILING C

SHELVES
3668 1640 FIXED 8' CEILING HEIGHT THROUGHOUT
3068 Cabinets Above, LOWER FLOOR 6"
73'8

WH

2'
CROWN MOLDING
CEILING UP

2'
2'6
8:12 SLOPE

Shelf, Base
U.N.O.
2868

4'

Cabinet
72'

72'
5/8" TYPE "X" GWB BETWEEN
CLOSET

8'1" CEILING
3068

CONCRETE GARAGE AND LIVING AREA TO 20-MINUTE MIN.


6'11

1660 FIXED 4060 SINGLE HUNG 1660 FIXED 5050 XO


LANDING GARAGE CEILING OR TO ROOF
WH
5068

SELF-CLOSING

2'
6'
SHEATHING SHELF & POLE
18" RAISED

4'
PLATFORM,
Enclosed in GAS CONCRETE PORCH
4' CROWN MOLDING 2019 FIXED 2019 FIXED
Closet FAU
CEILING UP
4:12 SLOPE

8'1" CEILING +90


(3) 2629 SINGLE CASEMENT
EGRESS 75" TOP HEIGHT

A 1660 FIXED 4060 SINGLE HUNG 1660 FIXED


(3)2X10 PORCH
BDRM 4 BEAMS
D B Storage Cabinet to
11'6

9
Floor to Ceiling 14' 5'5 1/2 4'6 1/2 2'6 3' 2'6
CLOSET

10'

2' 3'4 3'4 2'10


C
6'11

5068

5-1/8"X12" G.L.B. GARAGE DOOR HEADER TYP.

B
11
A 4:12 PITCH SHED DORMER
2'4 1/2 3'4 3'8 1/2 6'

19'
GARAGE
D B
9
18'X8' GARAGE

22'
DOOR W/OPENER C
2868 2868 2868
18080

Cabinet/Work Bench
11'6 6'6 14' 10' 8' 3'6
CLOSET 5'
A

8'1" CEILING BATH 4


6'11

CLOSET

5068

D B 2'
6'9

9
CEILING UP
8:12 SLOPE
36'5 1/2

36'5 1/2

50 CFM

6500 N. Mineral Dr. Coeur d'Alene, ID. 83815


www.chiefarchitect.com
TEMPERED C
GLASS
GARAGE
3'5

SHOWER
DOOR
2868

The WoodStone
DRYWALL, CARPET, OCCUPANCY SEPARATION:

3068
BETWEEN R-3 & U-1 SHALL BE A
& PAINT ATTIC

Chief Architect, Inc.


STORAGE MIN. 1 HR. CONSTRUCTION. MIN.
15'6

ACCESS STORAGE 5/8" G.W.B. SHALL EXTEND UP TO


2846

ROOF SHEATHING. IF USING THE


CONCRETE

3'
LID OPTION THEN 2 LAYERS REQ.
WHEN TRUSSES ARE GREATER LANDING “NOTICE AND DISCLAIMER
THAN 16" O.C. ALL POST &
CABINETS BUILT-IN BEAMS TO BE WRAPPED. MIN. This Sample Drawing is owned and/or licensed by Chief Architect, Inc. and is distributed with Chief Architect Software solely
BETWEEN TRUSSES 20-MINUTE SELF-CLOSING, for demonstrative and illustrative purposes as a way to help you more quickly learn and better understand the functional
TIGHT-FITTING, SOLID WOOD capabilities of the software program. You agree, under the License Agreement, that you will not reproduce, distribute or use
DOOR MIN. 1 3/8" THICK. these Sample Drawings for any other purpose without the prior written consent of Chief Architect, Inc..
5-1/8"X12" G.L.B. GARAGE DOOR HEADER TYP.

3'6
CHIEF ARCHITECT, INC. MAKES NO WARRANTY WHATSOEVER WITH REGARD TO THE SAMPLE DRAWINGS THAT
HAVE BEEN PROVIDED TO YOU SOLELY FOR DEMONSTRATIVE AND ILLUSTRATIVE PURPOSES. CHIEF
A ARCHITECT, INC MAKES NO WARRANTY THAT THE DIMENSIONS IN THESE SAMPLE DRAWINGS ARE ACCURATE

2050 FIXED
AND FREE OF DISCREPANCIES. CHIEF ARCHITECT, INC MAKES NO WARRANTY THAT THESE SAMPLE DRAWINGS
COMPLY WITH ANY BUILDING CODES. THESE SAMPLE DRAWINGS ARE PROVIDED TO YOU "AS IS," AND CHIEF
15'8 1/2

15'8 1/2

BONUS 9'X8' GARAGE


CEILING UP
8:12 SLOPE

D B ARCHITECT, INC. AND THE LICENSORS OF THESE SAMPLE DRAWINGS DISCLAIM ANY AND ALL WARRANTIES
9 DOOR W/OPENER WITH RESPECT TO THESE SAMPLE DRAWINGS, WHETHER EXPRESS OR IMPLIED OR ARISING BY CUSTOM OR
CEILING UP
8:12 SLOPE

TRADE USAGE, AND, SPECIFICALLY, MAKE NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY

800-482-4433
C

10'
PARTICULAR PURPOSE.

3'
(2) LAYERS 1/2" TYPE "X" GWB ON CEILING.
9080

TRUSSES ARE 24" O.C.


2050 FIXED
UNDER NO CIRCUMSTANCES WILL CHIEF ARCHITECT, INC, ITS RESELLERS, ITS DISTRIBUTORS OR THE
LICENSORS OF THE SAMPLE DRAWINGS BE LIABLE FOR ANY DAMAGES, WHETHER ARISING FROM TORT OR
CONTRACT, INCLUDING LOSS OF DATA, LOST PROFITS, COST OF COVER, OR OTHER SPECIAL, INCIDENTAL,
CONSEQUENTIAL OR INDIRECT DAMAGES ARISING OUT OF THE USE OF THESE SAMPLE DRAWINGS. PLEASE
REFER TO YOUR END USER SOFTWARE LICENSE AGREEMENT FOR MORE INFORMATION ABOUT THE TERMS AND
8'1" CEILING 3'6 CONDITIONS PURSUANT TO THESE SAMPLE DRAWINGS.”
8'6

5050 XO EGRESS
2'

MAIN FLOOR PLAN


16' 5' 220 Outlet 5050 FIXED 1/4" = 1'
2'

21' 2050 FIXED 2050 FIXED


3'6 3' 3'6 8' 8'
10' 16' 2'
28'
85'6
85'6 FLOOR FRAMING NOTES:

SHEET NUMBER
1. ALL JOISTS ARE TO BE 16" O/C. I-JOIST PER PLAN.
2' 16'6 1'8 3'8 1'8 14'6 23'4 1/2 18'7 1/2 3'6
2. PROVIDE CONTINUOUS BLOCKING OR RIM JOIST AT PERIMETER.

3. ALL CANTILEVERED JOISTS ARE TO HAVE LATERAL SUPPORT BLOCKING AT BEARING LOCATIONS - SEE PLANS.

4. PROVIDE PROPER BLOCKING IF REQUIRED AT ALL FLOOR PENETRATIONS.

1'8

1'8
5. PROVIDE JOIST HANGERS AT ALL LOCATIONS AT WHICH JOISTS BUTT UP TO BEAMS OF OTHER BUILT-UP JOISTS - SEE PLANS.

6. PROVIDE PRESSURE TREATED OR GALVANIZED FLASHING SEPARATION BETWEEN JOIST AND CONCRETE AT ALL LOCATIONS.

7. REFER TO I-JOIST MANUFACTURERS INSTALLATION DOCUMENTS FOR MISC. FRAMING SITUATIONS.

SCALE: SEE VIEW


CONCRETE NOTES:

DRAWN BY: A.F.


Aug 1, 2006
1. ALL CONCRETE IS TO BE MIXED TO A 2000 PSI RATING W/4" MAX. SLUMP.
AA
2. ALL BACKFILL AND SOIL BELOW SLABS AND FOOTINGS MUST BE COMPACTED TO 2000 PSF MIN.

3. FOUNDATION CONTRACTOR IS TO PROVIDE 1/2" X 10" ANCHOR BOLTS AT 72" O.C. AND 12" FROM CORNERS AT ALL PERIMETER
FOUNDATION WALLS AND ALL BEARING WALLS.
AA
14'

4. CONTRACTOR IS RESPONSIBLE FOR ALL REINFORCEMENT IN CONCRETE WALLS AND BELOW SLABS WHERE REQUIRED. ALL
REINFORCEMENT IS TO MEET LOCAL CODES AND IS TO BE INSPECTED BY BUILDING DEPT. OFFICIALS.

5. VENTILATION 1 S.F. PER 150 S.F. OF CRAWL SPACE. 2780 S.F.= 18.54 S.F. OF CRAWL SPACE VENTILATION REQUIRED.

20'
FOUNDATION STEEL:

WALLS UNDER 4'0":


#4 REBAR VERT. AT 48" O/C.

FOUNDATION PLAN
#4 REBAR HORIZ. AT 24" O/C.

WALLS OVER 4'0":


#4 REBAR VERT. AND HORIZ. AT 18" O/C.

FOOTINGS:
(2)#4 REBAR CONTINUOUS IN FOOTING.
BB
SHEAR WALL-A [SW-A]:
7'

4' MIN. WIDTH BRACE PANEL PER 1997 UBC 2320.11.3


NAILING: ALL PANEL EDGES - 8d AT 6" O/C. IN FIELD 8d AT 12" O/C.
SHEATHING TO COVER FULL DEPTH OF RIM JOISTS OR SOLID BLOCKED JOIST ENDS.

SHEAR WALL-B [SW-B]:

2'8" MIN. WIDTH ALTERNATE BRACE PANEL PER 1997 UBC 2320.11.4
NAILING: ALL PANEL EDGES - 8d AT 6" O/C. IN FIELD 8d AT 12" O/C.
PROVIDE TIE DOWNS AT ENDS OF PANEL WITH UPLIFT CAPACITY OF NOT LESS THAN 1800 LBS. SET INTO FOUNDATION.

7'
2X6 EXTERIOR WALL

SIMPSON IT HANGER

3/4" T&G STURDI-FLOOR


2X8 PT SILL SHEATHING GLUED AND
NAILED/SCREWED.
1/2"X10" AB 11-7/8" TJI-PRO 150 16" O/C
13'

BB FINISHED GRADE 2X12 PT RIM LET


INTO STEM WALL

AA

(2)#4 HORIZ. @ 24" O.C. W/I 6" TOP


& BOTTOM #4 VERT. @ 24" O.C.

11'
(2)#4 HORIZ. CONT. IN FTGS.

8"X16" FOOTING
8"X36" CONC.
STEM WALL
11"
73'8

73'8
2'

Chief Architect Sample Plan


3'2

2'
6'

4'
PERIM FOUNDATION DETAIL

WOODSTONE
AA
10"

11'6 3/8" = 1'

AA

3'
#3 REBAR 2' O/C EACH WAY IN SLABS AA
3/4" T&G PLYWOOD
FLOOR SHEATHING
R-30 INSULATION
DD

2'4
2X4 BEARING WALL

1'11 9/16
I-JOISTS
PROVIDE MIN. 18X24
18" MIN. ACCESS TO AREAS
9'2 2'4 6'6 2'4 2 - #4 STEEL REBAR
2X4 PT SILL PLATE
22'

8"
18'2

20'
1'4
24" DEEP PORCH PIERS WITH CONCRETE FTG
SIMPSON LCB66 AT CENTER

CC
GARAGE SLAB 1/4" PER FOOT
SLOPE TO DRAIN OUT DOORS INT. BEARING WALL DETAIL
BB 3/8" = 1'
GARAGE
38'

906 sq ft

1/2" CDX PLY 2X6 TREATED SILL


2' WALL SHEATHING PLATE W/SEALER
SIDING TOP OF FOUNDATION
PER SPECS
GARAGE FLOOR 4"
R-19 WALL CONCRETE SLAB W/#3

6500 N. Mineral Dr. Coeur d'Alene, ID. 83815


www.chiefarchitect.com
BUCK OUT AND SHOVEL
1'10

INSULATION REBAR 24" O.C. EACH WAY,


FOOTING WITH (2) #4 REBAR
OVER PEA GRAVEL FILL
CONTINUOUS ACROSS DOORS TYVEK
HOUSEWRAP

Chief Architect, Inc.


#4 REBAR VERT. AT 48" O/C.

2'4
8" #4 REBAR HORIZ. AT 24" O/C.

10'
9'2

(2)#4 REBAR CONT. IN FTGS.

8"
1'4

GARAGE FOUNDATION DETAIL


CC 3/8" = 1'

800-482-4433
2'
3'11

2'
GARAGE FLOOR 4" CONCRETE
SLAB W/#3 REBAR 24" O.C. EACH
WAY, OVER PEA GRAVEL FILL

2' 4' 10' 16' 2' 9'6 6'6 14' 10' 8' 3'6

#4 REBAR VERT. AT 48" O/C.


85'6

2'4
8" #4 REBAR HORIZ. AT 24" O/C.

(2)#4 REBAR CONT. IN FTGS.

8"
1'4

GARAGE FOUNDATION DETAIL


DD 3/8" = 1'
FLOOR FRAMING NOTES:

SHEET NUMBER
1. ALL JOISTS ARE TO BE 16" O/C. I-JOIST PER PLAN.

2. PROVIDE CONTINUOUS BLOCKING OR RIM JOIST AT PERIMETER.

3. ALL CANTILEVERED JOISTS ARE TO HAVE LATERAL SUPPORT BLOCKING AT BEARING LOCATIONS - SEE PLANS.

4. PROVIDE PROPER BLOCKING IF REQUIRED AT ALL FLOOR PENETRATIONS.

5. PROVIDE JOIST HANGERS AT ALL LOCATIONS AT WHICH JOISTS BUTT UP TO BEAMS OF OTHER BUILT-UP JOISTS - SEE PLANS.
STHD STHD STHD STHD
6. PROVIDE PRESSURE TREATED OR GALVANIZED FLASHING SEPARATION BETWEEN JOIST AND CONCRETE AT ALL LOCATIONS.

7. REFER TO I-JOIST MANUFACTURERS INSTALLATION DOCUMENTS FOR MISC. FRAMING SITUATIONS.

SCALE: SEE VIEW


CONCRETE NOTES:

DRAWN BY: A.F.


Aug 1, 2006
1. ALL CONCRETE IS TO BE MIXED TO A 2000 PSI RATING W/4" MAX. SLUMP.
AA
PAI35 IUT11
8' O.C. 2. ALL BACKFILL AND SOIL BELOW SLABS AND FOOTINGS MUST BE COMPACTED TO 2000 PSF MIN.
@ EACH
3. FOUNDATION CONTRACTOR IS TO PROVIDE 1/2" X 10" ANCHOR BOLTS AT 72" O.C. AND 12" FROM CORNERS AT ALL PERIMETER
FOUNDATION WALLS AND ALL BEARING WALLS.
AA
4. CONTRACTOR IS RESPONSIBLE FOR ALL REINFORCEMENT IN CONCRETE WALLS AND BELOW SLABS WHERE REQUIRED. ALL
REINFORCEMENT IS TO MEET LOCAL CODES AND IS TO BE INSPECTED BY BUILDING DEPT. OFFICIALS.

5. VENTILATION 1 S.F. PER 150 S.F. OF CRAWL SPACE. 2780 S.F.= 18.54 S.F. OF CRAWL SPACE VENTILATION REQUIRED.

FOUNDATION STEEL:

WALLS UNDER 4'0":


#4 REBAR VERT. AT 48" O/C.
#4 REBAR HORIZ. AT 24" O/C.
STHD

FLOOR FRAMING
WALLS OVER 4'0":
#4 REBAR VERT. AND HORIZ. AT 18" O/C.

FOOTINGS:
(2)#4 REBAR CONTINUOUS IN FOOTING.
BB
SHEAR WALL-A [SW-A]:

4' MIN. WIDTH BRACE PANEL PER 1997 UBC 2320.11.3


NAILING: ALL PANEL EDGES - 8d AT 6" O/C. IN FIELD 8d AT 12" O/C.
SHEATHING TO COVER FULL DEPTH OF RIM JOISTS OR SOLID BLOCKED JOIST ENDS.
11-7/8" TJI PRO 150 FLOOR STHD
SHEAR WALL-B [SW-B]:
JOISTS 16" O/C
2X4 FOUNDATION CRIPPLE 2'8" MIN. WIDTH ALTERNATE BRACE PANEL PER 1997 UBC 2320.11.4
WALLS WITH CONTINUOUS NAILING: ALL PANEL EDGES - 8d AT 6" O/C. IN FIELD 8d AT 12" O/C.
CRAWL PROVIDE TIE DOWNS AT ENDS OF PANEL WITH UPLIFT CAPACITY OF NOT LESS THAN 1800 LBS. SET INTO FOUNDATION.
STHD
8"X16" CONCRETE FOOTINGS SPACE
ACCESS

BB STHD

AA

ONE #4
REBAR IN
SHEAR CONE
12" MIN.
REBAR LENGTH
11"

STHD

2'

Chief Architect Sample Plan


MIN. REBAR
3'2

LENGTH 30"
STHD 1 "2
1
FASTEN WITH
STHD STHD 10dx1 1/2" NAILS

WOODSTONE
10"

INTO WEB STIFFENERS


Simpson Strong-Tie
CONTINUOUS 2X12 PT RIM
Simpson Strong-Tie PAI35
JOIST LET-IN TO STEM WALL
STHD Corner Installation (Hanger not Shown) Simpson Strong-Tie
AA
STHD STHD IUT11 (with web stiffener)

#3 REBAR 2' O/C EACH WAY IN SLABS AA


STHD PAI35 IUT11
3/4" T&G PLYWOOD STURD-I-FLOOR SHEATHING
2X8 PT MUD SILL GLUED AND SCREWED TO JOISTS
DD
SIMPSON IT JOIST HANGERS
FOUNDATION VENTS CAST INTO
STEM WALL
TOP OF JOIST FLUSH WITH TOP
9'2 2'4 6'6 2'4 OF MUD SILL
18'2

24" DEEP PORCH PIERS WITH


SIMPSON LCB66 AT CENTER

CC
GARAGE SLAB 1/4" PER FOOT
SLOPE TO DRAIN OUT DOORS

STHD

6500 N. Mineral Dr. Coeur d'Alene, ID. 83815


www.chiefarchitect.com
BUCK OUT AND SHOVEL
1'10

FOOTING WITH (2) #4 REBAR


CONTINUOUS ACROSS DOORS

Chief Architect, Inc.


9'2

800-482-4433
STHD
3'11

STHD

STHD STHD

BELOW FLOOR FRAMING


1/4" = 1'
SHEET NUMBER
TR-59

CANTILEVER ROOF TRUSSES OVER PATIO


TR-60

TR-46
TR-68

TR-73

TR-19
TR-72

8
-1
TR-46

TR-74

TR
TR-27

TR-71

SCALE: SEE VIEW


TR-70
TR- **

DRAWN BY: A.F.


TR-69
TR-19

Aug 1, 2006
TR
TR-67

-6
3
TR-45

TR-51
TR-66
TR-45

TR-65

TR-58
TR-20

TR-57

TR-56
TR-64
TR-26

TR-55
SCISSORS TRUSS CEILING RIDGE
TR-94
TR-26

TR-12
TR-76

TR-77

TR-78

TR-4

TR-5

TR-6

TR-7

TR-8

TR-9
GREAT ROOM

TR-17
TR-1
TR-42

TR-42

TR-42

TR-13

TR-14

TR-15

TR-16
TR-0

TR-11
TR-10
TR-81

TR-2
TR-3
TR-26

ROOF PLAN
GABLES AT EACH END OF VAULT
TR-54
TR-21
TR-53

TR-37

TR-33

TR-36

TR-38
TR-22
TR-52

TR-23
TR-50

TR
-4
3
TR-24
TR-49

TR-48 TR-25

TR-47 TR-31

TR
TR-39 TR-27

-3
4
TR-44 TR-30
TR-35

TR-79 TR-29
TR-28 TR-32

TR-88
TR-41 TR-40

Chief Architect Sample Plan


TR-89
TR-41

TR-89

WOODSTONE
TR-89
B
11

4:12 PITCH SHED DORMER


TR-89

8 / 12

8 / 12
TR-89
8 / 12 DN 8 / 12

TR-88 TRUSS NOTES: DN DN

1. ALL TRUSSES SHALL CARRY MANUFACTURERS STAMP.


TR-88

8 / 12
2. ALL TRUSSES SHALL BE INSTALLED & BRACED TO MANUFACTURERS SPECIFICATIONS.

8 / 12
TR-88
3. ALL TRUSSES WILL NOT BE FIELD ALTERED WITHOUT PRIOR BUILDING DEPT. APPROVAL OF
ENGINEERING CALCULATIONS. DN
TR-88 8 / 12
4. ALL TRUSSES SHALL HAVE DESIGN DETAILS & DRAWINGS ON SITE FOR FRAMING INSPECTION.

TR-82 5. NON BEARING WALLS SHOULD BE HELD DOWN FROM THE TRUSS BOTTOM CHORD W/ DN

8 / 12
SIMPSON STC TO INSURE THAT THE TRUSS BOTTOM CHORD WILL NOT BEAR ON THE WALL. DN 8 / 12
DN DN
TR-83
6. ALL CONNECTIONS OF RAFTERS, JACK OR HIP TRUSSES TO MAIN GIRDER TO BE PROVIDED DN
DN
BY TRUSS MANUFACTURE.

8 / 12

6500 N. Mineral Dr. Coeur d'Alene, ID. 83815


www.chiefarchitect.com
8 / 12
TR-84
DN DN DN
7. ALL ROOF FRAMING 24" O.C.
TR-90
TR-91
TR-92

TR-93

8 / 12
TR-85
8. ALL ROOF PITCH 8:12 UNLESS NOTED OTHERWISE (SHED DORMER 4:12) 8 / 12

Chief Architect, Inc.


DN
TR-86 9. TRUSSES MANUFACTURED BY ______________________________________-

8 / 12
10. ALL OVERHANGS 16". DN DN
TR-87 DN
8 / 12
11. ATTIC VENTILATION: 2780 S.F. / 300 = 9.3 S.F. REQUIRED ABOVE HOUSE. 8 / 12

8 / 12
DN DN

8 / 12
TR-62 8 / 12

8 / 12
12. PROVIDE 1" MIN. AIR GAP AT EAVES WITH INSULATION BAFFLES TYP. AT ALL TRUSS BAYS.

4 / 12
8 / 12
DN DN

8 / 12
DN B

TR-61 13. PROVIDE GABLE VENTS AS SHOWN ON ELEVATIONS. DN DN


11

800-482-4433
8 / 12
14. PROVIDE GALV. ROOF VENTS ON BACKSIDE OF ROOFLINE ABOVE CONDITIONED AREA.

8 / 12
8 / 12
DN

8 / 12

DN

DN

8 / 12
DN
2" Simpson Strong-Tie Simpson Strong-Tie
MIN.
END DIST. A35- Chimney Framing A35F
DN

Simpson Strong-Tie
Simpson Strong-Tie
THA29 DN 8 / 12
Simpson Strong-Tie H8 Hip Valley Truss
H15 DN DN 8 / 12
DN DN

8 / 12
SHEET NUMBER
TOP OF RIDGE
22'-10"
12
8 12
CONCRETE TILE ROOF
4
VENT UNDER TILES

GABLE END VENT

SCALE: SEE VIEW


1X10 CEDAR FASCIA

DRAWN BY: A.F.


13'9

Aug 1, 2006
TOP OF PLATE
9'-0"

1X8 CEDAR LAP SIDING

9'1

ELEVATIONS
CSV EUROPEAN

EXTERIOR
CASTLE STONE

FINISHED FLOOR
T.O.W. CONCRETE
GRADE

FRONT ELEVATION
1/4" = 1'

Chief Architect Sample Plan

WOODSTONE
LEFT QUARTER FRONT ELEVATION RIGHT QUARTER FRONT ELEVATION
1/8" = 1' 1/8" = 1'

6500 N. Mineral Dr. Coeur d'Alene, ID. 83815


www.chiefarchitect.com
Chief Architect, Inc.

800-482-4433
REAR PORCH REAR PORCH
LEFT ELEVATION
REAR ELEVATION RIGHT ELEVATION
1/4" = 1'
LEFT QUARTER REAR ELEVATION
1/8" = 1'
LEFT ELEVATION

RIGHT ELEVATION
1/4" = 1'

1/4" = 1'
RIGHT QUARTER REAR ELEVATION
1/8" = 1'

SCALE: SEE VIEW SHEET NUMBER


Chief Architect Sample Plan
Chief Architect, Inc. EXTERIOR Aug 1, 2006
6500 N. Mineral Dr. Coeur d'Alene, ID. 83815
800-482-4433 www.chiefarchitect.com WOODSTONE ELEVATIONS DRAWN BY: A.F.
ELECTRICAL NOTES

SHEET NUMBER
GENERAL ELECTRICAL: PER CURRENT ELECTRICAL CODES AND AS NOTED IN PLAN.

ELEXTRICAL BOXES TO SUPPORT FANS AND LARGE FIXTURES SHALL BE APPROVED FOR SUPPORTING SUCH LOADS.

COVERED JUNCTION BOXES SHALL BE PROVIDED UNDER KITCHEN SINKS TO PROVIDE POWER FOR DISHWASHERS, GARBAGE WP WP

DISPOSERS AND OTHER APPLIANCES AS REQUIRED. R

SMOKE DETECTORS: 4 4 3
R
R
SMOKE DETECTORS SHALL BE POWERED FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM A COMMERCIAL R R R
D/W
SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP.
R R R
SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING AREA, AT POINTS CENTRALLY LOCATED IN THE CORRIDOR OR 3

SCALE: SEE VIEW


AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA. 3

DRAWN BY: A.F.


3 WP WP 3
R R 3

Aug 1, 2006
SMOKE DETECTORS SHALL BE INSTALLED IN THE HALLWAY AND IN THE ADJACENT ROOM WHEN THE CEILING HEIGHT OF A 3
ROOM OPEN TO THE HALLWAY SERVING THE BETROOM EXCEEDS THAT OF THE HALLWAY BY 24" OR MORE. R
4 4

SMOKE DETECTORS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING IN WHICH THEY ARE
LOCATED.
R
LIGHTING: R R
THE PRIMARY LIGHTING FOR KITCHENS AND BATHROOMS SHALL HAVE A MIN EFFICIENCY OF 40 LUMENS PER WATT. R R R

AN EXTERIOR LIGHT SHALL BE PROVIDED FOR EACH EXIT.

A SWITCH FOR AN INTERIOR LIGHT SHALL BE PROVIDED AT EVERY ENTRANCE. SD R R R


R 3
R R SD
INCANDESCENT LIGHTS SHALL NOT BE PLACED CLOSER THAN 12" FROM THE NEAREST POINT OF A STORAGE AREA ON A R

ELECTRICAL PLAN
SHELF. 3 4 VAC SWITCH
R
3
INCANDESCENT LIGHT FIXTURES LOCATED IN CLOSETS SHALL BE SHIELDED.

SD
3
3
LIGHTING WILL BE PROVIDED FOR MECHANICAL EQUIPMENT LOCATED IN AN ATTIC OR UNDER FLOOR SPACE. A LIGHT GFCI

SD
SWITCH SHALL BE PROVIDED AT THE ACCESS OPENING.
4 3
R R
WP FIXTURE
R R
FIXTURES TO BE CHOSEN BY OWNER. R R
3
4 4 4 3
GFCI DM
R
3 R R
SD 3 UP R
R
3 3
R GFCI
3 DIMMER SWITCHES

3 4 4
GFCI
R
R
GFCI
3
R
ROPE LIGHT AT SD
R STRINGER CONTINUOUS
TOP TO BOTTOM.

SD
R R

R R
FLUORESCENT

3
R PHOTO CELL
3

3 4 4
DN 4 R R
3

R
4 4 FLUORESCENT
WP
WH
SD
CLOSET

3 WH
R

Chief Architect Sample Plan


WP
R R

SD

WOODSTONE
B
R 11

R R

Outlets,
Recessed
lighting in
eves
Fluorescent lighting
R GFCI
WP
TEMPERED
GLASS
SHOWER 4
DOOR
3

The WoodStone
SD
DRYWALL, CARPET,
& PAINT ATTIC
STORAGE

R R “NOTICE AND DISCLAIMER


CABINETS BUILT-IN This Sample Drawing is owned and/or licensed by Chief Architect, Inc. and is distributed with Chief Architect Software solely
BETWEEN TRUSSES for demonstrative and illustrative purposes as a way to help you more quickly learn and better understand the functional
R capabilities of the software program. You agree, under the License Agreement, that you will not reproduce, distribute or use ELECTRICAL SCHEDULE
these Sample Drawings for any other purpose without the prior written consent of Chief Architect, Inc..

6500 N. Mineral Dr. Coeur d'Alene, ID. 83815


www.chiefarchitect.com
CHIEF ARCHITECT, INC. MAKES NO WARRANTY WHATSOEVER WITH REGARD TO THE SAMPLE DRAWINGS THAT 110V DUPLEX OUTLET
HAVE BEEN PROVIDED TO YOU SOLELY FOR DEMONSTRATIVE AND ILLUSTRATIVE PURPOSES. CHIEF
ARCHITECT, INC MAKES NO WARRANTY THAT THE DIMENSIONS IN THESE SAMPLE DRAWINGS ARE ACCURATE 110V DUPLEX OUTLET WITH
Storage

GFI
AND FREE OF DISCREPANCIES. CHIEF ARCHITECT, INC MAKES NO WARRANTY THAT THESE SAMPLE DRAWINGS GROUND FAULT
COMPLY WITH ANY BUILDING CODES. THESE SAMPLE DRAWINGS ARE PROVIDED TO YOU "AS IS," AND CHIEF INTERRUPTER
Access area. ARCHITECT, INC. AND THE LICENSORS OF THESE SAMPLE DRAWINGS DISCLAIM ANY AND ALL WARRANTIES

WP
WATER PROOF 110V OUTLET
WITH RESPECT TO THESE SAMPLE DRAWINGS, WHETHER EXPRESS OR IMPLIED OR ARISING BY CUSTOM OR
Carpet, Paint TRADE USAGE, AND, SPECIFICALLY, MAKE NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE.
FLOOR MOUNTED OUTLET

Chief Architect, Inc.


UNDER NO CIRCUMSTANCES WILL CHIEF ARCHITECT, INC, ITS RESELLERS, ITS DISTRIBUTORS OR THE
LICENSORS OF THE SAMPLE DRAWINGS BE LIABLE FOR ANY DAMAGES, WHETHER ARISING FROM TORT OR 220V OUTLET
CONTRACT, INCLUDING LOSS OF DATA, LOST PROFITS, COST OF COVER, OR OTHER SPECIAL, INCIDENTAL,
CONSEQUENTIAL OR INDIRECT DAMAGES ARISING OUT OF THE USE OF THESE SAMPLE DRAWINGS. PLEASE SINGLE POLE SWITCH
REFER TO YOUR END USER SOFTWARE LICENSE AGREEMENT FOR MORE INFORMATION ABOUT THE TERMS AND
R R CONDITIONS PURSUANT TO THESE SAMPLE DRAWINGS.” 3 WAY SWITCH

3
CEILING FAN

R HEAT LIGHT FAN


4

4 TELEPHONE

TELEVISION

TV

800-482-4433
WP THERMOSTAT

T
INTERCOM

R R

C5/TV
DATA TERMINAL/TV
ELECTRICAL OUTLETS
CEILING PENDANT LIGHT
ELECTRIC OUTLETS IN BATHROOMS WITHIN SIX FEET OF SINKS, IN GARAGES, BASEMENTS AND OUTDOORS SHALL BE GFI PROTECTED.
WALL MOUNTED LIGHT FIXTURE
EXTERIOR OUTLETS SHALL HAVE WEATHER PROOF COVERS.
R RECESSED CEILING LIGHT FIXTURE
EXTERIOR ELECTRICAL OUTLETS SHALL BE PROVIDED AT THE FRONT AND BACK OF THE BUILDING.
SMOKE DETECTOR

SD
ELECTRICAL OUTLETS SHALL BE PLACED NOT FURTHER THAT 12' O.C. ON EVERY WALL AND SHALL BE PLACED ON WALLS GREATER THAN 2' IN LENGTH.

COUNTERTOPS 12" AND WIDER SHALL HAVE ELECTRICAL OUTLETS SPACED NOT GREATER THAN 48" O.C. ELECTRICAL PLAN CEILING FAN

HALLWAYS 10' OR GREATER IN LENGTH SHALL HAVE AT LEAST ONE ELECTRICAL OUTLET.
SCALE: 1/4"=1'0"
FLUORESCENT CEILING FIXTURE
MECHANICAL EQUIPMENT SHALL HAVE AN ELECTRICAL OUTLET LOCATED WITHIN 25'.

AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH ISLAND COUNTER SPACES WITH A LONG DIMENSION OF 24" OR GREATER AND A SHORT DIMENSION OF 12" OR GREATER. UNDER CABINET FLUORESCENT FIXTURE

PROVIDE TWO OR MORE DEDICATED 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS EVENLY PROPORTIONED IN THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM OR SIMILAR AREA. THE ELECTRICAL PLAN HAD BEEN PROVIDED AS A SCHEMATIC ONLY.
THE CONTRACTOR SHALL VERIFY THAT ALL ELECTRICAL IS
CONSISTENT WITH ALL APPLICABLE CODES AND LOCAL ORDINANCES.
AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH PENINSULA COUNTER WITH A LONG DIMENSION OF 24" OR GREATER AND A SHORT TIMENSION OF 12" OR GREATER.
SHEET NUMBER
B
11

11'2 2'4 3' 1'8 3'8 1'8 14'6 23'4 1/2 18'7 1/2

9' 2'2 1'10 1'10 5'10 4'8 4' 5'7 5'6 5'6 6'9 1/2 5'7 3/4 3'8 3'8 5'7 3/4

OPEN BELOW

C C
H C

SCALE: SEE VIEW

DRAWN BY: A.F.


Aug 1, 2006
4'9 1/2
C/W

C/W

C/W
w/W
D/W
DN

4'6
6'

6'
CLOSET
C/W C/W

9'
C

2'2
C/W

C/W
w/W
CLOSET

13'8 3/4
H/W
C/W
w/W

14'
BEDROOM MASTER BDRM

4'6 1/4

2'2
3'6

5'
G

C/W

C/W

C/W

20'
w/W
G
H/W
C/W
w/W
2'
5'6 KITCHEN

5'
G G G G

4'2 1/2
2'6
CLOSET

w
C/O

/W

C/W

C/W

C/W
w/W

HVAC PLAN
G

H/W
G
C/W
w/W

G G G G G G G G

PLUMBING/
PANTRY C/W C/W C/W C C/W C
H

2'5 1/2
2'4 1/2 3'4 3'8 1/2 6'

3'6

3'
2'9
C
C
FAMILY C

w
C

/W
H

H/W

H/W
C/W

C/W

C/W
w/W

w/W

w/W
7'
C/W C/W 3' C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W H 3'

G
BATH
H/W
C/W
w/W

3'2 4'8 6'2 C

38'
H
H H/W H
H/ W H/W H/W H/W H/W

3'6
H/W H/W H/W H/W H/W H/W H/W H/W H/W H/W H/W H/W
w

CLOSET
/W

w
C 1'1 1/2

/W
C
C/W C 3'6 3'8 4'2 8' 11'10 20'4 6' 2'4
2'8 1/4 C

7'8 1/4
CLOSET

w/W
H

H/W

H/W
C/W

C/W

C/W
w/W

w/W

w/W

w/W
5'1 1/2
G

3'6
w

UP
w

H/W
/W

TEMPERED
/W

w
/W
C C/W C/W C
GLASS w / W
3'5

H / WH
H SHOWERH/W H/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W w/W C/O

5'

7'
DOOR C / WC

5'4
2'
BATH MASTER BATH

w
/W

/W
C
DRYWALL, CARPET,

H/W

H/W
C/W

C/W

C/W
w/W

3'6
w/W

G
& PAINT ATTIC H
C

2'
C C/W C/W C/W C/W C
STORAGE 2'4 H
H/W H/W H/W

w
13'

/W
BEDROOM

2'5 1/2
CABINETS BUILT-IN
BETWEEN TRUSSES

H/W
C/W

C/W

w/W
G G G G G G G G G
DINING

CLOSET

G
G

6'8 3/8

w
8' 13'1

/W
LAUNDRY
7'8 1/2 OFFICE

14'8

11'
H/W
LIVING

H/W

H/W
C/W

C
w

w/W

w/W
/W

G
G C H
G
8'9 1/2
G
C/W

Chief Architect Sample Plan


C C/O H C H
6"
73'8

WH

2'
2'
2'6

WOODSTONE
C/W
H

w/W
G
WH
C
G

4'

C/W

w/W
G
C/O
2-WAY
11'6

2' 3'4 3'4 2'10 14' 5'5 1/2 4'6 1/2 2'6 3' 2'6

C/W

w/W
11

G
GENERAL MECHANICAL PLUMBING NOTES

19'

22'
ALL WATER SUPPLY PIPING TO BE COPPER, SIZED APPROPRIATELY FOR LOAD.

C/W

w/W
SOLDER TO BE LEAD FREE.

G
11'6 6'6 14' 10' 8' 3'6

ALL WASTE LINE TO BE CAST IRON, SIZED FOR APPLICATION. PROVIDE CLEANOUTS
PER UPC 2002 OR AS SHOWN ON PLAN.
C/W C

C/W

w/W
METALLIC GAS PIPE, WATER PIPE, AND FOUNDATION REINFORCING BARS SHALL BE

G
BONDED TO THE ELECTRICAL SERVICE GROUND. GARAGE

CLOSE DRYER, KITCHEN AND BATHROOM VENTING SHALL EXAHUST TO THE


OUTSIDE OF THE BUILDING AND BE EQUIPPED WITH A BACK DRAFT DAMPER.
The WoodStone

C/W

w/W
15'6

6500 N. Mineral Dr. Coeur d'Alene, ID. 83815


www.chiefarchitect.com
G
FURNACE, WATER HEATER, AND FIREPLACE FLUES SHALL EXAHUST TO THE

3'
“NOTICE AND DISCLAIMER
OUTSIDE OF THE BUILDING.
This Sample Drawing is owned and/or licensed by Chief Architect, Inc. and is distributed with Chief Architect Software solely
for demonstrative and illustrative purposes as a way to help you more quickly learn and better understand the functional
capabilities of the software program. You agree, under the License Agreement, that you will not reproduce, distribute or use
ALL GAS LINES SHALL BE SIZED FOR APPLIANCE LOAD. "BLACK" PIPE SHALL BE these Sample Drawings for any other purpose without the prior written consent of Chief Architect, Inc..

C/W

w/W

Chief Architect, Inc.


USED INSIDE THE BUILDING, "GREEN" PIPE WHERE UNDERGROUND OR EXPOSED

3'6
CHIEF ARCHITECT, INC. MAKES NO WARRANTY WHATSOEVER WITH REGARD TO THE SAMPLE DRAWINGS THAT
HAVE BEEN PROVIDED TO YOU SOLELY FOR DEMONSTRATIVE AND ILLUSTRATIVE PURPOSES. CHIEF
TO WEATHER. ALL JOINTS SHALL BE TAPED WHERE BURIED OR EXPOSED TO ARCHITECT, INC MAKES NO WARRANTY THAT THE DIMENSIONS IN THESE SAMPLE DRAWINGS ARE ACCURATE
AND FREE OF DISCREPANCIES. CHIEF ARCHITECT, INC MAKES NO WARRANTY THAT THESE SAMPLE DRAWINGS
WEATHER. COMPLY WITH ANY BUILDING CODES. THESE SAMPLE DRAWINGS ARE PROVIDED TO YOU "AS IS," AND CHIEF
ARCHITECT, INC. AND THE LICENSORS OF THESE SAMPLE DRAWINGS DISCLAIM ANY AND ALL WARRANTIES
WITH RESPECT TO THESE SAMPLE DRAWINGS, WHETHER EXPRESS OR IMPLIED OR ARISING BY CUSTOM OR
TRADE USAGE, AND, SPECIFICALLY, MAKE NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY
TUBS/SHOWERS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE

10'
PARTICULAR PURPOSE.

3'
C/W

w/W
G
PRESSURE BALANCE OR THE THERMOSTATIC MIXING TYPE. THE WATER UNDER NO CIRCUMSTANCES WILL CHIEF ARCHITECT, INC, ITS RESELLERS, ITS DISTRIBUTORS OR THE
LICENSORS OF THE SAMPLE DRAWINGS BE LIABLE FOR ANY DAMAGES, WHETHER ARISING FROM TORT OR
TEMPERATURE SHALL BE AT A MAXIMUM OF 120*F. CONTRACT, INCLUDING LOSS OF DATA, LOST PROFITS, COST OF COVER, OR OTHER SPECIAL, INCIDENTAL,
CONSEQUENTIAL OR INDIRECT DAMAGES ARISING OUT OF THE USE OF THESE SAMPLE DRAWINGS. PLEASE
REFER TO YOUR END USER SOFTWARE LICENSE AGREEMENT FOR MORE INFORMATION ABOUT THE TERMS AND
CONDITIONS PURSUANT TO THESE SAMPLE DRAWINGS.”
WATER HEATER SHALL BE PROVIDED WITH SEISMIC RESTRAINTS AS SHOWN.

3'6

800-482-4433
C/W

w/W
G

HOSE BIBBS ARE REQUIRED IN FRONT AND REAR OF BUILDING OR AS NOTED ON


8'6

PLAN. EACH HOSE BIBB SHALL BE EQUIPPED WITH A BACK FLOW PREVENTION
DEVICE.

2'
FUEL BURNING WATER HEATERS SHALL BE INSTALLED PER 2002 UPC SECTION C
C/W

w/W
G

501.0 AND TABLE 5-1 FOR COMBUSTION AIR. 2'

A HEATING SYSTEM SHALL BE PROVIDED CAPABLE OF MAINTAINING A ROOM


TEMPERATURE OF 70* F AT A POINT 3' ABOVE THE FLOOR IN ALL HABITABLE 3'6 3' 3'6 8' 8'
10' 16' 2'
ROOMS.
C/W

w/W
G

28'

HEAT DUCTING SHALL BE SECURED, SEALED AND INSULATED.

ANY APPLIANCE GENERATING A GLOW, SPARK, OR FLAME CAPABLE OF IGNITING


FLAMMABLE VAPORS SHALL BE INSTALLED 18" ABOVE THE FLOOR.
C/W

w/W
G
5' 16' 5'

SHEET NUMBER
ROOFING PER SPECS

ATTIC

9'2 7/16
BEDROOM

SCALE: SEE VIEW


ENGINEERED ATTIC

DRAWN BY: A.F.


ROOF TRUSSES
DORMER

Aug 1, 2006
8'1 1/8
BONUS
(FAMILY ROOM)

6' 5/16
ATTIC ATTIC

3'10 3/16
R-38 INSULATION
SIMPSON H-1 TRUSS TO
(2) LAYERS 1/2" TYPE "X" DRYWALL TOP PLATE CONNECTORS
GARAGE CEILING
(2)2X10 HEADERS TYPICAL
UNLESS NOTED OTHERWISE

SECTIONS
DETAILS
5/8" TYPE "X" DRYWALL
MASTER BEDROOM OFFICE GARAGE WALLS

2X6 STUD WALL

10'3 1/4
1/2"X10" AB's @ 6' O.C. WITHIN
12" BREAKS AND CORNERS GARAGE
R-21 INSUL. 1/2" CDX PLY
2X6 STUDS 16" O/C 2X6 STUDS 16" O/C WALL SHEATHING 2X6 TREATED SILL PLATE W/SEALER
R-21 INSUL. 1/2" GWB
1/2" GWB BLOCKING ABOVE SIDING PER PLAN
SIDING PER PLAN FLOOR SHEATHING
BLOCKING ABOVE CRIPPLE WALL TOP OF FOUNDATION
FLOOR SHEATHING GLUED & SCREWED TYVEK HOUSEWRAP
TYVEK HOUSEWRAP CRIPPLE WALL SIDING
GLUED & SCREWED 7/16" OSB EXTERIOR PER SPECS
7/16" OSB EXTERIOR I-JOISTS FLOOR SHEATHING I-JOISTS GARAGE FLOOR 4" CONCRETE SLAB W/#3
I-JOISTS FLOOR SHEATHING I-JOISTS WALL SHEATHING REBAR 24" O.C. EACH WAY, OVER PEA
WALL SHEATHING R-30 INSUL. GLUED & SCREWED
GLUED & SCREWED R-30 INSUL. 2X6 PLATE R-19 WALL GRAVEL FILL
2X6 PLATE R-30 INSUL. R-30 INSUL.
INSULATION
2X6 P.T. SILL 2X6 P.T. SILL
RIM JOIST RIM JOIST TYVEK
HOUSEWRAP
1/2"X10" AB'S 1/2"X10" AB'S
8"

8"

8"
FINISHED GRADE 1/2"X10" AB'S 1/2"X10" AB'S DBL 2X4 TOP PLATE FINISHED GRADE
DBL 2X4 TOP PLATE
PER PLAN PER PLAN
24"

24"
6" 6 MIL VAPOR BARRIER 6"
KEYWAY 2X4 P.T. SILL PLATE 2X4 P.T. SILL PLATE KEYWAY
6 MIL VAPOR BARRIER EXTEND MIN. 1' UP WALL

2'4
EXTEND MIN. 1' UP WALL 8"
REBAR PER REBAR PER
8"

8"
STRUCTURAL STRUCTURAL
8"

8"
REBAR PER FND NOTE REBAR PER FND NOTE
ENGINEER ENGINEER
14" 16" 16" 14"

8"

Chief Architect Sample Plan


#4 REBAR VERT. AT 48" O/C.
#4 REBAR HORIZ. AT 24" O/C.
(2)#4 REBAR
40 1/4 X 49 X 24 CONT. IN FTGS. 1'4

WOODSTONE
APPLIANCE SPECIFICATIONS FRAMING SPECIFICATIONS
MODEL: CST 38 NOTE: FRAMING DIMENSIONS ARE CALCULATED FOR A
NAILING FLANGE DEPTH OF 1/2". SECTION 2 GARAGE AND ATTIC TRUSS SECTION
1' 1/2
SECTION SCALE: 3/8"=1'0" SECTION SCALE: 3/8"=1'0"
10 1/2"
4' 3/4

5 1/4"

4'1
2'8
1'9
5 3/4"

3'2 END VIEW


3'3 1/4
LEFT FRONT VIEW

1' 1/2

SKYLIGHT SHAFT
4' 3/4
3'6 1/2

3'6 3/4

GAS LINE
COMBUSTION AIRACCESS
3 7/8"
2 13/16"
3 1/16"

FRONT VIEW
END VIEW

4X4
HEADER
2X4
FALSE HEADER
(OPTIONAL)
2'1 3/16

1'11 15/16
8"

3'6 3/4

3'3 1/4
TOP VIEW 2 9/1
6"

3'4 1
/4 1'1
11
5/1
6
BEDROOM BATH BONUS ROOM
SUPERIOR. FRAMING
STAIR WELL

6500 N. Mineral Dr. Coeur d'Alene, ID. 83815


www.chiefarchitect.com
sf18.dwg

Chief Architect, Inc.


7'2 1/2

JOIST/HEADER

800-482-4433
KITCHEN HALL GARAGE
ATTACH TO HEADER WITH TH
STEEL HEADER ATTACHMENT B
LAMINATED SUPPORT BEAM

NOTE:

SECTION 3
SECTION SCALE: 3/8"=1'0"
SHEET NUMBER
3'8 2'6 2'7 2'6 2'6 1'2 10" 7'6 2'3

SCALE: SEE VIEW

DRAWN BY: A.F.


Aug 1, 2006
INTERIOR ELEVATIONS
2'6 15/16 2'6 2'6 1'6 3' 2' 5'6 1/2 2' 2'

KITCHEN - C KITCHEN - D KITCHEN - A

PERSPECTIVES
DINING ROOM VIEWS
CEILING, INTERIOR TRIM

Chief Architect Sample Plan

WOODSTONE
KITCHEN PERSPECTIVES MASTER BED ROOM VIEWS
CEILING, INTERIOR TRIM

6500 N. Mineral Dr. Coeur d'Alene, ID. 83815


www.chiefarchitect.com
3'6 2'3 1'6 2'3
2' 2'6

Chief Architect, Inc.


MASTER BATH VANITY BATH - 4 VANITY BATH - 2 VANITY

FAMILY ROOM VIEWS


CEILING, INTERIOR TRIM
3'8 3'3 3'8

800-482-4433
APPLIANCE SCHEDULE
3'7 3'5 3'7
NUMBER QTY FLOOR DIMENSIONS WIDTH DEPTH HEIGHT DESCRIPTION CODE MANUFACTURER COMMENTS QTY NUMBER
A01 1 1 26 3/4X22X60 1/2 " 26 3/4 " 22 " 60 1/2 " STACKED 27" 1 A01
A02 1 1 36X30 3/4X66 " 36 " 30 3/4 " 66 " SIDE-BY-SIDE 1 A02
A03 1 1 28X27X42 " 28 " 27 " 42 " DRYER (ELECTRIC) 1 A03
A04 1 1 24X40X45 " 24 " 40 " 45 " DOUBLE SIDED 1 A04
A05 1 1 18 1/2X28 5/8X60 " 18 1/2 " 28 5/8 " 60 " 18" W/ GAS@UPFLOW 1 A05
A06 2 1 12X108X8 " 12 " 108 " 8" GARAGE@DOOR OPENER 2 A06
A07 1 1 30X20X1 7/8 " 30 " 20 " 1 7/8 " GAS 30" 1 A07

OFFICE CABINETRY STAIRCASE VIEW


SCALE: SEE VIEW SHEET NUMBER
Chief Architect Sample Plan
Chief Architect, Inc. INTERIOR ELEVATIONS Aug 1, 2006
6500 N. Mineral Dr. Coeur d'Alene, ID. 83815
800-482-4433 www.chiefarchitect.com WOODSTONE PERSPECTIVES DRAWN BY: A.F.