You are on page 1of 5

12/08/2021 Crimper Qualification Log 1

(DO Not Write On This Form!)


DATE CONTACT sizes SPECIFIED CRIMPER AWG 2nd MPF Lbs PIC HAVE SUB CRIMPER
1 28-Jun-07 031-9/074-002 20 M22520/1-01 turret TH1A 20 13 27 YES
2 28-Jun-07 031-9/095-003 16 M22520/1-01 turret TH1A 16 30 60 YES
3 16-Aug-07 Amp 1-175216-5 28-24 Amp 91565-1 24 6 12 NO 90066-7
4 30-Jan-08 AMP 1-175217-3 24-20 AMP 91559-1 20 13 22 YES NO
5 23-May-07 AMP 1-175217-3 24-20 AMP 91559-1 24 6 7.8 Yes YES NO
6 28-Jan-08 AMP 1-175218-2 20-16 AMP 91558-1 20 13 36
7 28-Jan-08 AMP 1-175218-5 20-16 AMP 91558-1 16 30 50
8 12-Jul-07 AMP 1-175218-5 20-16 AMP 91558-1 18 20 37 NO YES NO
9 23-May-07 AMP 1318107-1 22-18 AMP 91595-1 (Won't fit) 18 20 26 YES 90066-7 #18 Only
10 23-May-07 AMP 1318107-1 22-18 AMP 91595-1 20 13 19 Yes YES NO
11 10-Jan-08 AMP 1318108-1 28-24 91576-1 24 6 13 YES NO
12 7-Aug-07 AMP 1318111-1 22-18 Amp 91595-1 18 20 35 YES
13 2-Aug-07 Amp 1-66506-0 24-20 Amp 90302-1 22 8 14 YES
14 30-Apr-07 AMP 171638-1 20-16 AMP 91536-1 18 20 26 Yes NO HTR - 60622
15 30-Apr-07 AMP 171638-1 20-16 None Specified 18 18 20 50 NO NO 90546-1
16 17-Jan-08 AMP 1747498-2 14-12 AMP 1762129-1 12 70 70.3 NO NO 088-3AA
17 23-May-07 AMP 1747499-2 16-14 AMP 1762130-1 16 30 33 Yes YES NO
18 23-May-07 AMP 1747499-2 16-14 AMP 1762130-1 18 20 27 Yes YES NO
19 17-May-07 AMP 175288-2 24-20 AMP 91559-1 20 13 23.8 NO YES NO
20 6-Feb-08 AMP 175288-2 24-20 amp 91559-1 24 6 13 YES
21 12-Jul-07 AMP 175289-5 20-16 AMP 91558-1 16 30 55 Yes YES NO
22 12-Jul-07 AMP 175289-5 20-16 AMP 91558-1 18 20 37 Yes YES NO
23 11-Jan-08 Amp 175289-5 20/16 91558-1 20 13 26.8 YES NO
24 15-Nov-08 AMP 1-917511-5 16-14 AMP 91560-1 14 50 73 NO NO AMP 90546-1
25 30-Apr-07 AMP 202507-1 18-16 AMP 90136-1 or 601967-1 18 20 36 Yes NO HDT-4800
26 25-May-07 AMP 205089-1 (M) 20 AFM8 and M22520/2-02 20 13 16.9 YES setting #8
27 25-May-07 AMP 205090-1 (F) 20 AFM8 and M22520/2-02 20 13 20.5 YES setting #8
12/08/2021 Crimper Qualification Log 2
(DO Not Write On This Form!)
DATE CONTACT sizes SPECIFIED CRIMPER AWG 2nd MPF Lbs PIC HAVE SUB CRIMPER
28 23-May-07 AMP 316040-2 16-14 AMP 234170-1 16 30 57 Yes YES NO
29 7-Feb-08 AMP 316040-2 16-14 234170-1 18 20 37 YES
30 23-May-07 AMP 316041-2 (triple) 12-10 AMP 234171-1 16 30 >110 NO YES NO
31 8-Aug-07 Amp 350551-1 20-14 90298-1 - 90299-1 16 30 58 NO Amp 90166-1-G
32 8-Aug-07 Amp 350552-2 20-14 90298-1 - 90299-1 16 30 48 NO Amp 90166-1-G
33 25-May-07 AMP 66099-4 18-16 AMP 90067 16 30 55 YES
34 7-May-07 AMP 66099-4 18-16 AMP 91523-1 or 90067-5 18 20 46.4 Yes YES NO
35 25-May-07 AMP 66099-4 18-16 AMP 90067 20 13 30 YES
36 4-Feb-08 amp 66101-1 18-16 amp 90067 16 30 44 YES
37 3-Aug-07 Amp 66101-4 18-16 Amp90067 18 20 43 YES
38 11-May-07 AMP 66103-4 24-20 AMP 90066-7 24 6 11.4 NO YES NO
39 27-Nov-07 Amp 66589-1 18-16 58495-1 18 20 33 YES
40 27-Nov-07 Amp 66589-2 18-16 58495-1 18 20 40 YES
41 17-Aug-07 Amp 770987-3 22-18 Amp 91522-1 20 13 14 NO 91559-1
42 20-Feb-08 AMP 770988-1 22-18 Amp 91522-1 20 13 22 NO HTR - 1719C
43 12-Jul-07 AMP 794019-1 30-24 90870-1 24 6 9 YES no
44 17-May-07 AMP 917512-2 16-14 AMP 91560-1 20 16 30 55 NO NO AMP91558-1
45 2-Jul-07 AMP 917512-2 Double Only 16-14 91560-1Use Sub for double 16 16 30 46 Yes NO 90546-1
46 21-Jan-08 AMP 917804-2 16-14 234710-1 14 50 87 NO YES NO
47 12-Jul-07 AMP 917804-2 16-14 AMP 234170-1 16 30 63 Yes YES NO
48 12-Jul-07 AMP 917804-2 16-14 AMP 234170-1 18 20 31 Yes YES NO
49 2-Jul-07 AMP 917805-2 12-10 AMP 234171-1E 12 70 >110 YES NO
50 3-Aug-07 Deutch 72341-09-355n Kit pins 38943-22 24 6 11 NO AFM8-Ms27490
51 30-Apr-07 JAE JN1-22-20S 21-20 JAE CT150-2-JN1-D 22 8 12.1 Yes NO 90222-6
52 7-Feb-08 JAE JN1-22-22S 25-21 JAE CT150-2-JN1-B 22 8 16 NO 90222-6
53 23-May-07 JAE JN1-22-22S 25-21 JAE CT150-2-JN1-B 24 6 8.1 Yes NO 90222-6
54 12-Nov-08 m39029/31-228 AF8-TH1A or WA22 20 13 26 NO YES NO
12/08/2021 Crimper Qualification Log 3
(DO Not Write On This Form!)
DATE CONTACT sizes SPECIFIED CRIMPER AWG 2nd MPF Lbs PIC HAVE SUB CRIMPER
55 12-Jul-07 m39029/5-115 AF8-TH1A or WA22 20 13 18 YES NO
56 12-Jul-07 m39029/5-115 AF8-TH1A or WA22 24 6 13 YES NO
57 12-Jul-07 mol 08-50-0106 26-18 638117500 24 6 12 YES
58 12-Jul-07 mol 08-52-0113 26-18 638117500 24 6 10.5 YES
59 24-Sep-07 mol 02-09-1104 24-14 molex 63811-3200 16 30 60 YES
60 29-Jun-07 MOL 08-50-0114 30-22 MOL 0011010185 24 6 13 Yes NO MOL HTR2262A
61 27-Sep-07 mol 39-00-0047 28-22 molex 63811-5100 22 8 15.1 YES
62 17-May-07 Mol 39-00-0049 28-22 Molex 63811-5100 24 6 14 NO YES NO
63 15-Nov-08 MOL 39-00-0164 24-18 molex 63811-5000 22 8 22 NO YES NO
64 16-May-07 Mol 56052 -8100 18-16 Molex 57406-5000 16 30 53 Yes YES NO
65 16-May-07 Mol 56052 -8100 18-16 Molex 57406-5000 18 20 25 Yes YES NO
66 23-May-07 RB114-250A (Double) CT260 (Green Hndl) 16 30 >110 YES NO
67 19-Jun-07 SHF-001T-0.8BS-LP EDP# 11-01-0198-E 20 13 16 YES
68 17-Jul-07 T&B RA18-47pt WT 145C 22 8 18.5 YES
69 17-Jul-07 T&B RA18-47pt Double WT 145C 22 22 8 37 YES
70 8-Apr-08 02-09-1104 14 63811-1000 14 35 60 NO NO 63811-3200 (A)
71 9-Apr-08 02-09-2103 14 63811-1000 14 35 60 NO NO 63811-3200 (A)
72 30-Apr-08 Mol 5556pbtl/ 39-00-1066 22-28 Molex 063811-5100 26 4 10 NO YES

Not Approved Not Approved


AMP 1-917511-5 16-14 AMP 91560-1 18 20 55 Yes NO AMP 91558-1
AMP 1-175216-5 28-24 AMP 91565-1 NO NO
AMP 1-175218-3 20-16 AMP 91558-1 Yes YES NO
AMP 1318912-3 (KIT 1473063-2) AMP 1366402-1 Yes NO HTR2262A
AMP 35055-2 20-14 AMP 91506-1 Yes NO AMP 90166-1-G Type F
AMP 66105-4 24-20 AMP 90066-7 Yes YES NO
12/08/2021 Crimper Qualification Log 4
(DO Not Write On This Form!)
DATE CONTACT sizes SPECIFIED CRIMPER AWG 2nd MPF Lbs PIC HAVE SUB CRIMPER
AMP 770988-3 22-18 AMP 91522-1/90711-2 Yes NO HTR 1719C
LCAS6-14-L T&B CAT # TBM5 Yes YES NO
Molex 08-07-1040 20-14 Molex 63811-5200 Yes NO HTR 2262a
Molex 19221-0236 Molex 19284-0034 Yes NO T&B cat # TBM5
New Crimp Qualification Form
C A B D E
2nd SUB CRIMPER
DATE CONTACT sizes SPECIFIED CRIMPER Serial Number AWG wire MPF Lbs If reqd

10

11

12

(The size specified for contact!)


Note 2: Column "D" (Minimum Pull out force) must not exceed "E" actual test result.

Note 3 : The relevant sales representitive must be notified of a misfit contact/wire or substituted crimper.

You might also like