You are on page 1of 1

Job:(AS) / T1 THIS DWG. PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS)SUBMITTED BY TRUSS MFR.

Top chord 2x4 SP 2400f-2.0E 90 mph wind, 15.00 ft mean hgt, ASCE 7-05, OPEN_CLEAR bldg, Located anywhere in roof, CAT II, EXP C, wind TC DL=6.0
Bot chord 2x4 SP #1 psf, wind BC DL=6.0 psf.
Webs 2x4 SP #3
Wind reactions based on MWFRS pressures.
Left and right cantilevers are exposed to wind
Roof overhang supports 2.00 psf soffit load.
Deflection meets L/360 live and L/240 total load.
Truss designed for unbalanced snow load, based on Pf=Pg=20.00 psf.

$70.00 EACH + TAX + $50 DELIVERY

11'8"2 11'8"2

12
2.12
4X6
4X4 4X4
3X4 3X4
2'5"

2'9"4

2'9"4
2X6(A1) 2X6(A1)
4"5 10'4"8
1.5X3 6X8 3X4 1.5X3
3X4

7'8"2 8'
2'4"4 2'4"4
23'4"4
R=1328# U=300# RL=90/-90# W=6"
R=1328# U=300# W=6"

LEFT RAKE = 2'4"11 RIGHT RAKE = 2'4"11


LEFT JIG = 11'11"1 RIGHT JIG = 11'11"1
TAG = T1 SEQ = 290034
PLT. TYP.-WAVE DESIGN CRIT=IBC2006/TPI-2002 FT/RT=20%(0%)/10(0) QTY= 2 TOTAL= 2 REV. 10.01.01.0604.14 SCALE =0.2500
**WARNING**
TRUSSES REQUIRE EXTREME CARE IN FABRICATING, HANDLING, SHIPPING, INSTALLING AND
BRACING. REFER TO BCSI (BUILDING COMPONENT SAFETY INFORMATION), PUBLISHED BY TPI (TRUSS PLATE TC LL 20.0psf REF
INSTITUTE, 218 NORTH LEE STR., SUITE 312, ALEXANDRIA, VA. 22314) AND WTCA (WOOD TRUSS COUNCIL
OF AMERICA, 6300 ENTERPRISE LN, MADISON, WI. 53719) FOR SAFETY PRACTICES PRIOR TO PERFORMING
THESE FUNCTIONS. UNLESS OTHERWISE INDICATED, TOP CHORD SHALL HAVE PROPERLY ATTACHED STRUCTURAL
TC DL 10.0psf DATE 01-14-2011
PANELS AND BOTTOM CHORD SHALL HAVE A PROPERLY ATTACHED RIGID CEILING.
**IMPORTANT**
FURNISH COPY OF THIS DESIGN TO INSTALLATION CONTRACTOR. ITW BCG, INC. SHALL BC DL 10.0psf DRWG
NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THIS DESIGN; ANY FAILURE TO BUILD THE TRUSS IN
CONFORMANCE WITH TPI; OR FABRICATING, HANDLING, SHIPPING, INSTALLING & BRACING OF TRUSSES.
DESIGN CONFORMS WITH APPLICABLE PROVISIONS OF NDS (NATIONAL DESIGN SPEC,BY AF&PA) AND TPI.
BC LL 0.0psf
ITW BCG CONNECTOR PLATES ARE MADE OF 20/18/16GA (W,H/SS/K) ASTM A653 GRADE 40/60 (W,K/H,SS)
GALV. STEEL. APPLY PLATES TO EACH FACE OF TRUSS AND, UNLESS OTHERWISE LOCATED ON THIS DESIGN, TOT.LD. 40.0psf O/A LEN. 280012
POSITION PER DRAWINGS 160A-Z. ANY INSPECTION OF PLATES FOLLOWED BY (I) SHALL BE PER ANNEX A3
OF TPI 1-2002 SEC. 3. A SEAL ON THIS DRAWING INDICATES ACCEPTANCE OF PROFESSIONAL ENGINEERING
RESPONSIBILITY SOLELY FOR THE TRUSS COMPONENT DESIGN SHOWN. THE SUITABILITY AND USE OF THIS
DUR.FAC. 1.15 JOB #: AS
COMPONENT FOR ANY BUILDING IS THE RESPONSIBILITY OF THE BUILDING DESIGNER,
PER ANSI/TPI 1 SEC. 2.
SPACING 24.0" TYPE COMN