You are on page 1of 10

INGENIERIA BASICA

CONSTRUCCION DE CARTA PSICROMETRICA


La carta se construyó a partir de la teoría, aquí solo se muestran los cálculos
realizados. La carta psicrométrica es para el sistema aire-agua a 560 mmHg (10.83
psia) de presión.

1. Humedad absoluta. Figura 15.

MV PA
Y=
( )(
MG PT −P A )
en donde:
Y: Humedad absoluta.
MV: Peso molecular del vapor.
MG: Peso molecular del gas.
PA: Presión parcial del vapor de la mezcla.
PT: Presión total de la mezcla.

Tabla 1. Humedad absoluta.


T, ºF P, psia Y,100% Y,90% Y,80% Y,70% Y,60%
32 0.088600 0.0051 0.0046 0.0041 0.0036 0.0031
40 0.121710 0.0071 0.0063 0.0056 0.0049 0.0042
50 0.178213 0.0104 0.0093 0.0083 0.0073 0.0062
60 0.256597 0.0151 0.0136 0.0121 0.0105 0.0090
70 0.363687 0.0216 0.0194 0.0173 0.0151 0.0129
80 0.507920 0.0305 0.0275 0.0244 0.0214 0.0183
90 0.699580 0.0429 0.0386 0.0343 0.0300 0.0257
100 0.951100 0.0598 0.0538 0.0478 0.0418 0.0359
110 1.277250 0.0830 0.0747 0.0664 0.0581 0.0498
120 1.695490 0.1152 0.1037 0.0922 0.0806 0.0691
130 2.226190 0.1606 0.1445 0.1285 0.1124 0.0964
140 2.892930 0.2262 0.2036 0.1810 0.1584 0.1357
150 3.722750 0.3251 0.2926 0.2601 0.2276 0.1951
160 4.746370 0.4843 0.4358 0.3874 0.3390 0.2906

Y,50% Y,40% Y,30% Y,20% Y,10% Y,5% Y,2%


0.0026 0.0020 0.0015 0.0010 0.0005 0.0003 0.0001
0.0035 0.0028 0.0021 0.0014 0.0007 0.0004 0.0001
0.0052 0.0042 0.0031 0.0021 0.0010 0.0005 0.0002
0.0075 0.0060 0.0045 0.0030 0.0015 0.0008 0.0003
0.0108 0.0086 0.0065 0.0043 0.0022 0.0011 0.0004
0.0153 0.0122 0.0092 0.0061 0.0031 0.0015 0.0006
0.0214 0.0171 0.0129 0.0086 0.0043 0.0021 0.0009
0.0299 0.0239 0.0179 0.0120 0.0060 0.0030 0.0012
0.0415 0.0332 0.0249 0.0166 0.0083 0.0041 0.0017
0.0576 0.0461 0.0346 0.0230 0.0115 0.0058 0.0023
0.0803 0.0642 0.0482 0.0321 0.0161 0.0080 0.0032
0.1131 0.0905 0.0679 0.0452 0.0226 0.0113 0.0045
0.1626 0.1300 0.0975 0.0650 0.0325 0.0163 0.0065
0.2421 0.1937 0.1453 0.0969 0.0484 0.0242 0.0097

2. Curvas de saturación adiabática. Figura 16.

T 1 =[ λ s ( Y s −Y 1 ) / s ]+ T s , ° F

en donde:
λs: Calor latente de vaporización a la temperatura de saturación.
Ys: Humedad de saturación.
Y1: Humedad.
s: Calor específico húmedo.
Ts: Temperatura de saturación.

Tabla 2. Curvas de saturación.


λ = 1065.35 λ = 1059.6 λ = 1054 λ = 1048.3
T, ºF Y T, ºF Y T, ºF Y T, ºF Y
50 0.0104 60 0.0151 70 0.0216 80 0.0305
62.63 0.0075 77.58 0.0110 98.06 0.0150 120.10 0.0210
73.68 0.0050 99.57 0.0060 119.87 0.0100 150.41 0.0140
84.84 0.0025 112.96 0.0030 142.09 0.0050 181.50 0.0070
96.10 0 126.50 0 164.72 0 213.41 0

λ = 1042.7 λ = 1037 λ = 1031.3 λ = 1025.5


T, ºF Y T, ºF Y T, ºF Y T, ºF Y
90 0.0429 100 0.0598 110 0.0830 120 0.1152
134.52 0.0320 158.80 0.0450 198.80 0.0600 270.63 0.0750
177.05 0.0220 221.73 0.0300 281.84 0.0400 374.75 0.0500
221.14 0.0120 288.10 0.0150 370.89 0.0200 488.19 0.0250
276.22 0 358.20 0 466.61 0 612.28 0
λ = 1019.8 λ = 1014 λ = 1008.1 λ = 1002.2
T, ºF Y T, ºF Y T, ºF Y T, ºF Y
130 0.1606 140 0.2262 150 0.3251 160 0.4843
270.83 0.1200 391.38 0.1500 396.56 0.2400 469.77 0.3600
427.81 0.0800 589.12 0.1000 683.50 0.1600 863.42 0.2400
606.70 0.0400 820.76 0.0500 1045.29 0.0800 1401.69 0.1200
812.42 0 1095.83 0 1515.62 0 2182.16 0

3. Entalpia del aire húmedo. Figura 17.

H=s ( T −T r ) +Yλr btu / lb aire sec o

en donde:
H: entalpia del aire húmedo.
s: Calor especifico húmedo.
T: Temperatura.
Tr: Temperatura de referencia.
Y: Humedad.
λr: Calor latente de vaporización del vapor a la temperatura T r.

Tabla 3. Entalpias del aire húmedo.


T Y100 H100 H90 H80 H70 H60
32 0.0051 5.5078 4.9570 4.4062 3.8555 3.3047
40 0.0071 9.5349 8.7734 8.0119 7.2504 6.4889
50 0.0104 15.5759 14.4503 13.3247 12.1991 11.0735
60 0.0151 23.1146 21.4751 19.8356 18.1962 16.5567
70 0.0216 32.6916 30.3344 27.9773 25.6201 23.2630
80 0.0305 45.0372 41.6855 38.3337 34.9820 31.6303
90 0.0429 61.1509 56.4278 51.7048 46.9817 42.2586
100 0.0598 82.4356 75.8241 69.2125 62.6010 55.9894
110 0.0830 110.9128 101.6935 92.4742 83.2550 74.0357
120 0.1152 149.6235 136.7732 123.9228 111.0725 98.2221
130 0.1606 203.3761 185.3905 167.4049 149.4193 131.4337
140 0.2262 280.2942 254.8568 229.4194 203.9819 178.5445
150 0.3251 395.3421 358.6399 321.9377 285.2355 248.5333
160 0.4843 579.5736 524.6882 469.8029 414.9175 360.0322

H50 H40 H30 H20 H10 H5 H2


2.7539 2.2031 1.6523 1.1016 0.5508 0.2754 0.1102
5.7274 4.9660 4.2045 3.4430 2.6815 2.3007 2.0723
9.9480 8.8224 7.6968 6.5712 5.4456 4.8828 4.5451
14.9173 13.2778 11.6384 9.9989 8.3595 7.5397 7.0479
20.9058 18.5486 16.1915 13.8343 11.4772 10.2986 9.5914
28.2786 24.9269 21.5752 18.2234 14.8717 13.1959 12.1903
37.5355 32.8124 28.0893 23.3662 18.6431 16.2815 14.8646
49.3778 42.7663 36.1547 29.5431 22.9316 19.6258 17.6423
64.8164 55.5971 46.3778 37.1586 27.9393 23.3296 20.5639
85.3718 72.5214 59.6711 46.8207 33.9704 27.5452 23.6901
113.4480 95.4624 77.4768 59.4912 41.5056 32.5128 27.1171
153.1071 127.6697 102.2323 76.7948 51.3574 38.6387 31.0075
211.8311 175.1289 138.4266 101.7244 65.0222 46.6711 35.6604
305.1468 250.2614 195.3761 140.4907 85.6054 58.1627 41.6971

4. Volumen húmedo. Figura 18.

1 Y 760 t+460
VY=
( +
)( )(
M G M V PT 492 )
( 359 ) , ft 3 / lb aire seco

en donde:
VY: Volumen húmedo en ft3/lb aire seco
MG: Peso molecular del gas.
Y: Humedad absoluta.
MV: Peso molecular del vapor.
PT: Presión total mmHg.
T: Temperatura en °F.

Tabla 3. Entalpias del aire húmedo. Figura 18.


T Y100 VY100 VY90 VY80 VY70 VY60
32 0.0051 16.9391 16.9252 16.9114 16.8975 16.8836
40 0.0071 17.2677 17.2483 17.2289 17.2095 17.1901
50 0.0104 17.7065 17.6774 17.6482 17.6191 17.5900
60 0.0151 18.1875 18.1444 18.1014 18.0583 18.0152
70 0.0216 18.7270 18.6641 18.6012 18.5383 18.4754
80 0.0305 19.3469 19.2562 19.1655 19.0747 18.9840
90 0.0429 20.0780 19.9483 19.8186 19.6889 19.5592
100 0.0598 20.9635 20.7794 20.5953 20.4112 20.2271
110 0.0830 22.0664 21.8062 21.5459 21.2857 21.0254
120 0.1152 23.4816 23.1140 22.7464 22.3788 22.0112
130 0.1606 25.3598 24.8386 24.3173 23.7960 23.2747
140 0.2262 27.9561 27.2093 26.4626 25.7158 24.9690
150 0.3251 31.7405 30.6494 29.5584 28.4673 27.3762
160 0.4843 37.6890 36.0372 34.3854 32.7337 31.0819

VY50 VY40 VY30 VY20 VY10 VY5 VY2


16.8698 16.8559 16.8421 16.8282 16.8144 16.8074 16.8019
17.1707 17.1513 17.1319 17.1125 17.0931 17.0834 17.0756
17.5608 17.5317 17.5026 17.4734 17.4443 17.4297 17.4181
17.9721 17.9290 17.8859 17.8428 17.7997 17.7782 17.7609
18.4125 18.3496 18.2868 18.2239 18.1610 18.1295 18.1044
18.8932 18.8025 18.7118 18.6210 18.5303 18.4849 18.4486
19.4295 19.2998 19.1701 19.0404 18.9107 18.8459 18.7940
20.0430 19.8589 19.6748 19.4907 19.3066 19.2146 19.1409
20.7652 20.5050 20.2447 19.9845 19.7242 19.5941 19.4900
21.6435 21.2759 20.9083 20.5407 20.1731 19.9893 19.8422
22.7534 22.2321 21.7108 21.1895 20.6682 20.4076 20.1991
24.2222 23.4755 22.7287 21.9819 21.2352 20.8618 20.5631
26.2852 25.1941 24.1031 23.0120 21.9209 21.3754 20.9390
29.4302 27.7784 26.1266 24.4749 22.8231 21.9972 21.3365

ELECCION DE LA TORRE Y CALCULO DE LA SECCION TRANVERSAL


Se instaló una torre de enfriamiento de tiro inducido (debido a su mayor seguridad y
rendimiento) para trabajar 600 l/h de agua que entran a la torre a 94ºF. De acuerdo a
los datos obtenidos de CONAGUA, Anexo B, en la ciudad de Toluca se tiene una
temperatura húmeda “5 por 100” de 51ºF y se manejó una aproximación de 13ºF a la
temperatura de humedad.

En las torres de enfriamiento la razón aire-agua (lb/lb) varía normalmente entre 1 y


1.5, y el intervalo de velocidades del aire es normalmente entre 6 y 8 ft/seg. Se utilizó
un valor de 1.25 para la razón aire-agua y 3.61ft/seg para la velocidad del aire, u.
Con estos datos se calculó el número de unidad de transferencia y su tamaño.

Caudal de aire
G=1 .25 L
L=10 l /min=0 . 1667 l/seg
( 0 .1667 )( 1000 ) ( 2. 2 )
m=V ∗ρ= =0 . 3667 lb/seg
1000
G=1 .25 L=0. 4584 lb/seg
Para las condiciones del aire de entrada se deduce del diagrama psicrométrico o de
la ecuación 7, que el volumen saturado, V s, a 51ºF es 17.75 ft3/lb. Por tanto el área
de la sección transversal requerida en la torre, A, es
GV s
A= =2 . 25 ft 2
u

Las cargas de gas y de líquido y la velocidad del aire referidas a esta área son:
G 0 . 4582
G''= = =0 . 2036 lb/seg ft 2
A 2. 25
L 0 . 3667
L''= = =0 . 1639 lb/ seg ft 2
A 2 . 25
u=G ''* V s =0 .2036∗17 . 75=3 . 6139 ft / seg

Evaluación de las condiciones de operación


Se pueden obtener las condiciones en la interfase usando un método grafico. Se
traza una gráfica con coordenadas de temperatura de la fase liquida contra la
entalpia de la fase gaseosa. En ella se pueden graficar los valores de la curva de la
interfase Hi y Ti, considerando que en la interfase, la fase vapor estará saturada a la
temperatura de la interfase cuando sea posible suponer que existe un equilibrio en el
límite de una fase.

En la misma gráfica se puede trazar una "línea de operación" de H g contra TL, con
una pendiente L/G (puesto que numéricamente el calor específico del agua es la
unidad). Esta curva representa la trayectoria de las condiciones de la fase global a
medida que el fluido pasa a través de la unidad.

La figura 19 muestra uno de los diagramas para una operación de humidificación. La


curva de equilibrio que ahí se representa se obtuvo conociendo las dos condiciones
extremas (TL1, HG1) y (TL2, HG2), o a partir de cualquiera de estos puntos y la
pendiente L/G.
Figura 19. Representación grafica de una operación
de contacto adiabático gas-liquido.

La línea de equilibrio se traza a partir de los datos de temperatura y entalpias al


100%, contenidos en la tabla 3.

La línea de operación se traza con los dos puntos de las condiciones extremas.

Tenemos que:
T L =64 ° F
1

T L =93 ° F
2

Del balance de entalpias:


G ( H G2−H G 1 ) =L ( H L2 −H L1 )

L ( H L 2−H L1 )
H G =H G +
2 1 G

de la ecuación 5
H G =( 0 . 24+ 0. 45 Y ) ( T −T r ) +Yλr
1
H G = 16 . 27 Btu/lb aire sec o
Por lo tanto 1

H L =Cp Δt 1
H L =Cp Δt
i { 1

H L 2 =Cp Δt 2 }
de lo anterior
H L =( 1. 0 Btu/lb ° F ) (64−32 ) ° F= 32 Btu /lb
1

H L =( 1. 0 Btu/lb ° F ) ( 93−32 ) ° F= 61 Btu /lb


2

entonces
H G =39 . 47 Btu/lb aire sec o
2

Por lo tanto los puntos extremos de la línea de operación son:

(T L , H G ) =( 64 , 16 . 27 )
1 1 y (T L , H G ) =( 93 , 39 . 47 )
2 2

El diagrama que se obtuvo del desarrollo anterior se muestra en la figura 20.

Calculo de la altura de relleno


La altura de la torre, z, es igual al producto del número de unidades de transferencia
por la altura de una unidad de transferencia.

z=NUT G∗LUT G

Número de unidades de transferencia del gas


Para la evaluación del número de unidades de transferencia del gas, NUT G, se utilizo
el método Baker.

Método grafico de Baker


Se localizan los puntos medios de las fuerzas impulsoras, es decir, de los valores H i -
H, uniendo dichos puntos mediante una línea (línea media). Desde el punto de
operación de la parte superior, B, se traza una paralela al eje de las abscisas hasta la
línea media, punto C, y se prolonga de forma que BC=CD. Desde el punto D se traza
una perpendicular a BD hasta la línea de operación, punto E. El escalón BDE
representa una unidad de transferencia del gas. Se repite el procedimiento
empezando en E. Se obtiene un valor fraccionario de una unidad de transferencia,
igual a EF/EG. Figura 21.

Figura 21.Determinacion del número de unidades de transferencia por el método Baker.

Con este método se obtuvo que NUT G es igual a 1.5, como se muestra en la figura
22.

Altura de la unidad de transferencia


Para el tipo de relleno seleccionado, puede emplearse aproximadamente la siguiente
expresión:
k h a=6 . 72G ''0 .75

en donde:
kha: Coeficiente volumétrico de transferencia de materia, kg/h m 3
G'': Caudal másico del aire, kg/h m2

Para este caso


k h a=6 . 72 ( 3578 )0. 75=0 . 0538 lb/ft 3 seg
G ''
LUT G= =3 .7749 ft
kh a
z=NUT G∗LUT G
z=1 .5∗3.7749=5. 66 ft