TOTAL POWER AND CAPTIVE POWER REQUIREMENT FOR VARIOUS PLANT CAPACITIES
PLANT CAPACITY, TPD 1200 3000 4500 TOTAL POWER REQUIREMENT, MW 9.5 23.5 29.0 CAPTIVE POWER* REQUIREMENT, MW 3 7 9
* TAKING CAPTIVE POWER REQUIREMENT @30% OF TOTAL POWER FOR MAINTAINING CONTINUOUS PRODUCTION FROM KILN
UPTO 25-30% OF TOTAL POWER REQUIREMENT CAN BE MET THROUGH COGENERATION OF POWER UTILISING WASTE HEAT IN A CEMENT PLANT
OVERSEAS SCENARIO
KOREA UTILISATION OF WASTE HEAT FROM COOLER VENT, EACH 2 X 5500 TPD COOLER TO UTILISE FORCED CIRCULATION WATER TYPE HIGH PRESSURE AND LOW PRESSURE WHB SYSTEM GAS FLOW : 5,66,000 AM3/H AT 370oC FROM EACH COOLER POWER GENERATION : 9100 KW (NET) ~ 17.5 KWH/T CEMENT
RECENT DEVELOPMENTS
WASTE HEAT BOILER THERMOWIR REMOVING 60% (48-60gm/NM3) DUST FROM THE GASES REDUCING LOAD ON EXISTING ESP HIGHER EFFICIENCY COMPARED CONVENTIONAL HEAT EXCHANGERS TO
RECENT DEVELOPMENTS
MODIFIED RANKINE CYCLE SYSTEM KALINA CYCLE USES BINARY FLUID OF AMMONIA AND WATER EFFICIENCY GAINS OF UPTO 50% FOR LOW TEMPERATURE (200-280oC) AND UPTO 20% FOR HIGHER TEMPERATURE HEAT SOURCES COMPARED TO RANKINE CYCLE
RECENT DEVELOPMENTS
ORMAT ENERGY CONVERTER (OEC) USES ORGANIC FLUID AS WORKING MEDIUM INSTEAD OF STEAM SUITABLE FOR MUCH LOWER TEMPERATURE HEAT SOURCES AS ORGANIC FLUID HAS A MUCH LOWER BOILING POINT THAN WATER
NCB IDENTIFIED BY MOCI, GOVT OF INDIA TO DISSEMINATE TECHNOLOGY AFTER SUCCESSFUL IMPLEMENTATION OF DEMONSTRATION PROJECT AT INDIA CEMENT LTD., VISHNUPURAM UNDER GREEN AID PLAN.
CONTINUING EFFORTS
TECHNICAL SUPPORT FOR INSTALLATION COGENERATION POWER PLANTS. OF
A B C D E F G H I J
3000, 4ST* 4500, 5ST 3300, 4ST 3000, 4ST* 3300, 6ST 3300, 6ST 2X2800, 6ST 2X1700, 5ST 3300, 4ST* 2250, 5ST 2500, 4ST
4.6 5.5 4.5 4.0 3.2 3.2 4.4 4.2 4.2 3.2 3.0
CONTD ...
K L M N O P *
2225, 5ST 2225, 5ST 3250, 6ST 3000, 4ST 3700, 4ST 2000, 5ST
PLANTS AMENABLE FOR COGENERATION: TOTAL COGENERATION CAPACITY, MW EXPECTED POWER SAVINGS : :
40 160
UPTO 25-30% OF
PLANTS REQUIREMENT
: :
63 52 115
: :
PERCENTAGE REDUCTION AS COMPARED TO EMISSIONS DUE TO ELECTRICITY CONSUMPTION (i.e. 8.4 MILLION TONNES/YEAR) : 18
PREHEATER EXHAUST
195427
390
260 4.0
II COOLER EXHAUST
182588
300
230
ECONOMIC EVALUATION
COGENERATION POTENTIAL, MW ESTIMATED COST, Rs MILLION DEBT/EQUITY RATIO REPAYMENT OF LOAN, YEARS INTEREST RATE, PER ANNUM COST OF PURCHASED POWER, RS/KWH PAYBACK PERIOD, YEARS : : : : : : : 4.0 260 75:25 10 13% 4 3.5
WASTE HEAT RECOVERY SYSTEM INSTALLED UNDER GREEN AID PLAN BY KAWASAKI HEAVY INDUSTRIES, JAPAN AT THE INDIA CEMENTS LIMITED VISHNUPURAM, WADAPALLY (A.P.)
T/Y
46093
DESIGN BASIS
ITEMS Volumetric flow rate Temperature at Boiler Inlet Temperature at Boiler Outlet Dust Content UNIT Nm3/h Deg.C Deg.C G/ Nm3 PH 360,750 340 230 50-60 AQC 191,600 360 90 5*1
EQUIPMENT SPECIFICATION
ITEMS EVAPORATION RATE STEAM PRESSURE BOILERS STEAM TEMP FEED WATER TEMP HEAT RECOVERY VALUE STEAM TURBINE OUTPUT CAPACITY GENERATOR POWER FACTOR TERMINAL VOLTAGE FREQUENCY UNIT T/H MpaG Deg.C Deg.C Kj / h KW KVA % V Hz PH BOILER 28.20 1.57 315 200 AQC BOILER 14.63 1.70 345 56
ECONOMIC EFFICIENCY
QUANTITY OF POWER GENERATED IN-HOUSE POWER CONSUMPTION NET QUANTITY OF POWER GENERATED QUANTITY OF COOLING WATER REDUCED POWER PURCHASED PRICE OF POWER PURCHASED ANNUAL REDUCITON OF QUANTITY OF POWER PURCHASED ANNUAL SAVING OF POWER FEE KW KW KW T/h KW Rs.. /kwh 106 kwh 7,700 800 6,900 26.5 7,080 4.15 56.07
Million Rs. /y
232.7