You are on page 1of 8

4 5 1389

1 1 2 3
.1
.2
.3
:
. 15
.
.
.
.
.
. .
0.25 11.2
2.47 24.10 .

:
.1


.


.

.

.


.
.

PowerPlant 89 GTME-1964


4 5 1389



.

.

15
101.35
60
.


.
10
15 20 .

200
11000 . 20

2200
.

.
35
12 V94.2.5
6
.
.
. 159
160 .
1 .[4]

-1 .[4]

PowerPlant 89 GTME-1964


4 5 1389

Massflow
TurbineExhaustTemperature
110
105
103.68

100
95
90

89.93

85

.2

PercentofISOrating





.


GT PRO

GTMASTER
.
Thermoflow
.

.
.
42.316
26.96 .
3 .

45

35

25

15

AmbientTemperature,C

-2

GTgrosspower

STgrossoutput

170
160
150
140
130
120
110
100

14.59
113.90



.
40 21.248
15.72
15
0.62

0.74 [2] 16.6

45

35

25

15

)Power(MW

2


. 40

10
.

4

.

)AmbientTemperature(C

-3



4
PowerPlant 89 GTME-1964


1389
45

. 40

.
1.84 4.65 44.04
4
Steameff

50

35

135

30

130

25

125

20

120

45

44.66

35
32.28

30

22.79
35

25

15

Efficiency
Effi i

40

45

40

140

80

100

60

40

20

)Power(MW

G
GTeff

Planteeff

GTnettefficiency

GTnetoutput

Ambientrelativehumidiity

25

-5

20

A
AmbientTem
mperature(C
)C


.3
-4

.
5 .
155
100



. 0.08
0.6 .

[6
Kakaras ]][3 ]6
K

. Kakarass ] [3
4..3




.
0.28 2.7

. [8].

.






] .[1
.

.


.
75
7

[1].
.4



PowerPlaant 89 GTM
ME-1964


4 5 1389


.
.
.

] .[7


.

WithFoggingSysytem
WithoutFoggingSysytem
49

47
46
44.91
44.66

45

)Efficiency(%

48

44

5 0 5 10 15 20 25 30 35 40 45
)AmbientTemperature(C

WithFoggingSysytem
WithoutFoggingSysytem

366.38
330.00


)Power(MW

460
440
420
400
380
360
340
320
300

-7

.5

5 0 5 10 15 20 25 30 35 40 45
)AmbientTemperature(C

-6

21.64
95 25

2.96 .
6 7

. 11.02
0.25
] [3 2.7 0.28
4.3
.



.
] [1 .

.
5


.
.

.
.

.
2 COP

PowerPlant 89 GTME-1964


1389
45

2490
4.411 10982
40
.
WitthMechanicalChillerSysyte
em
WitthoutMechan
nicalChillerSyysytem

330
0

)Power(MW

404.66

460
440
420
400
380
360
340
320
300

5 0 5 10 15
1 20 25 30 35
5 40 45
)AmbientTTemperature(C



-8

. 2.88

22.62
.


.



.


.

10 .
.


.

.


.

.

WitthMechanicalChillerSysyte
em

WitthoutMechan
nicalChillerSyysytem
49
47.54

47
46
44.66
6

45

)Efficiency(%

48

44
5 20 25 30 35
5 40 45
5 0 5 10 15
)AmbientTTemperature((C


-9

8 9





[9]

-10



PowerPlaant 89 GTM
ME-1964


1389
45





] .[[9 11
.

GTgrosspow
werwihchillerrsystem
GTgrosspow
werwihoutchiillersystem
STgrossoutp
putwihchillerrsystem
STgrossoutp
putwihoutchiillersystem
170
160
)Power(MW

98
156.9

150

140
135.2
29

130
120

114.5
58
113.8
89

110

1 15 20 25 30 35 40 45
5 0 5 10
Ambie
)entTemperatture(C


-12




WithChillerSystem
m
Witho
outChillerSysstem

-11 ] [9

409.64
4

330.

)Power(MW

40

21.64
155

.




.



109822
19448
COP 0.67


COP 1.1 13445
C
.

460
440
420
400
380
360
340
320
300

1 15 20 25 30 35 40 45
5 0 5 10
Ambie
)entTemperatture(C

-13



PowerPlaant 89 GTM
ME-1964


4 5 1389
WithChillerSystem
WithoutChillerSystem
50
49

47
46

)Efficiency(%

48.13

48

45

44.66

44
5 0 5 10 15 20 25 30 35 40 45
)AmbientTemperature(C

-14


37 18.78
12 . ][2
11.3 .
13 24.10 .
14
3.47 .
.6



.

.
.

.
.

.

.

.

[1] ASHRAE Handbook series, (2008), HVAC


Systems and Equipment, Chapter 17
[2] Ameri, M., Hejazi, SH. (2004), The study
of capacity enhancement of the Chabahar gas
turbine installation using an absorption
chiller. Appl Thermal Eng; 24:5968.
[3] Kakaras, E., Doukelis, A. Karellas, S.
(2004) Compressor intake-air cooling in gas
turbine plants, Energy 29, 23472358
[4] Documents of DAMAVAND Combined
Cycle, MOSHANIR Co. 2010
[5] Kakaras, E., Doukelis, A. Prelipceanu, A.
Karellas, S. (2006) Inlet Air Cooling Methods
for Gas Turbine Based Power Plants,
Transactions of the ASME, Vol. 128,
)[6] Mohanty, B., Poloso, G., (1995
Enhancing gas turbine performance by intake
air cooling using an absorption chiller. Heat
Recovery Syst CHP; 15(1):4150.
)[7] Jolly, S., Cloyd, S., and Hinrichs, J (2005
Wet compression adds power,flexibility to
aeroderivative GTs. Power 149(4).
)[8] Jolly, S., Nitzken, J., Shepherd, D., (1998
Evaluation of Combustion Turbine Inlet Air
Cooling Systems, Power-Gen Asia, New
Delhi, India September 29-October 1,
[9] Desai, P.S. (2004) Modern Refrigeration
and Air Conditioning for Engineers, 1rs Ed,
Chapter 6, KHANNA Publishers, Delhi

PowerPlant 89 GTME-1964

You might also like