You are on page 1of 7

LINE LIST ABBREVIATION-1

1. PLANT IDENTIFICATION CODE


SYSTEM CODE COMMON / GENERAL ONSHORE 50: LNG PROCESS TRAIN6 52: LNG PROCESS TRAIN7 53: STORAGE AND LOADING 57: REFRIGERANT MR: MIXED REFRIGERANT NR: NITROGEN REFRIGERANT PR: PROPANE REFRIGERANT SOLVENT SV: SX: AMINE SOLVENT SELEXOL FUEL FG: FO: WATER BW: CHS: CHR: CW: HW: DM: DW: RW: SR: CATALYST CA: CATALYST SS: SW: TW: BOILER FEED WATER / SOFTENED WATER CHILLED WATER SUPPLY CHILLED WATER RETURN COOLING WATER (FRESH) SUPPLY COOLING WATER (FRESH) RETURN DEMINERALIZED WATER DRINKING WATER RAW WATER (DESALINATED WATER) SEA WATER RETURN SEA WATER SUPPLY SERVICE WATER TEMPERED WATER CORROSION ALLOWANCE 0: 0.0MM 1: 1.2MM OR 1.6MM 3: 3.0MM 4: 4.0MM 6: 6.0MM BASIC PIPING MATERIAL A: B: C: J: K: M: N: W: Y: CARBON STEEL LOW TEMPERATURE CARBON STEEL CLADED STEEL TYPE 304 STAINLESS STEEL TYPE 316 STAINLESS STEEL HASTELLOY INCOLOY 825 CARBON STEEL (WATER SERVICE) LOW ALLOY STEEL (1-1/4CR-1/2MO)

6. PAINT CODE TABLE


ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 PAINT CODE 1C 2C 3C 8C 6R' 5D 6D 7D 6R 6S 7R 7S 7H 6A 6B 17 AA AB AC AD B PIPING MAT'L CS / LA CS / LA CS / LA CS / LA CS / LA CS / LA CS / LA CS / LA SS SS SS SS SS ALUMINUM ALUMINUM Cu-Ni CS
HOT DIP GALV'ZED

FUEL GAS FUEL OIL

58: 59:

OFF SITES UTILITES

INSULATION OPE. TEMP REMARKS NONE -46100 FLEX TO 120 NONE 101200 NONE 201400 FLEX TO 538 NONE 401500 NONE -46100 FOR SUCTION PIPE INTERNAL COATING FOR MAIN AIR BLOWER (24-K0911A/B, LINE NO: A2409001) YES YES YES NONE YES NONE YES NONE / YES NONE YES NONE NONE NONE NONE NONE NONE 121500 -46120 -172-47 -46120 -46120 -172-47 -172-47 121500 -46120 -46120 -46120 70 70 70 90 70 FLEX TO 177

UNIT CODE 00: COMMON / GENERAL DOWNSTREAM 02: ACID GAS REMOVAL / AMINE STORAGE 03: DEHYDRATION/MERCAPTAN REMOVAL/MERCURY REMOVAL 04: NGL RECOVERY 05: 06: 07: 08: 09: 30: 31: 32: 33: 71: 72: 74: 77: 78: 82: 83: 84: 86: 87: 91: 92: 93: 94: 95: 96: GAS CHILLING AND LIQUEFACTION REFRIGERATION FRACTIONATION / LPG TREATING NITROGEN REJECTION SULFUR RECOVERY COMMON / GENERAL UPSTREAM ONSHORE INLET FACILITIES CONDENSATE TREATING WASTE WATER INJECTION LNG STORAGE AND LOADING REFRIGERANT MAKE-UP AND STORAGE LNG JETTY CONDENSATE STORAGE REFRIGERATED LPG STORAGE SEA WATER SYSTEMS FIRE PROTECTION SYSTEMS FLARE AND LIQUID BURNERS SULFUR EXPORT EFFLUENT TREATMENT / SITE DRAINAGE POWER GENERATION / DISTRIBUTION STEAM SYSTEMS FUEL SYSTEMS FRESH WATER SYSTEMS COMPRESSED AIR SYSTEMS NITROGEN SYSTEMS

CHEMICAL AC: ACID CH: CHEMICAL ME: METHANOL NA: CAUSTIC SODA

SUFFIX (AS REQUIRED) A: ALUMINEZED

FOR FIRE FIGHTING WATER LINE RED-COLOR IDENTIFICATION COAL TAR EPOXY EXTERNAL COATING FOR U/G PIPING HB EPOXY EXTERNAL COATING FOR U/G PIPING HB EPOXY EXTERNAL COATING FOR U/G PIPING EPOXY PHEOLIC COATING FOR U/G PIPING TAPE WRAP EXTERNAL PROTECTION FOR U/G PIPING

ANCILLARY FLUID
BLOWDOWN BD: BLOWDOWN CV: DRY GAS FLARE DB: DRY LIQUID BLOWDOWN RV: WET GAS FLARE / TANKAGE GAS FLARE SF: SOUR GAS FLARE WB: WET LIQUID BLOWDOWN OIL FLUID FF: FLUSHING FLUID HO: HOT OIL HY: HYDRAULIC OIL LO: LUBE OIL SO: SEAL OIL GAS FLUID SG: SEAL GAS DRAIN DR: DRAIN FIRE CD: DF: DP: CARBON DIOXIDE DILUTED FOAM SOLLUTION DRY POWER (CHEMICAL) FIRE WATER HIGH EXPANSION FOAM CONCENTRATE LOW EXPANSION FOAM CONCENTRATE

B:
C:

LTCS FOR PIPE, FLANGE & FITTINGS


CEMENT LINED

D: E:
F: G: H: J: K: L: M:

KCS + ALLOY 825 CLAD KCS + ALLOY 625 CLAD


FLARE LINED GALVANIZED High Carbon (for Stainless Steel) JACKETED PIPE TYPE 316L SS CLAD LOW CARBON (FOR SS) LTCS + Type 316L Stainless Steel Clad

SS CS/SS/GALV ALL

7. HOT / COLD INSULATION CODE TABLE


ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 INS. CODE 1 2 3A 3B 3C 4A 4B 4C 4D S S1 S2 E JF JS 5 6 1ST AND 2ND LETTER (INS. TYPE) HOT INSULATION (HEAT CONSERVATION) PERSONAL PROTECTION SOUND CONTROL TYPE 3A SOUND CONTROL TYPE 3B SOUND CONTROL TYPE 3C SOUND CONTROL TYPE 4A SOUND CONTROL TYPE 4B SOUND CONTROL TYPE 4C SOUND CONTROL TYPE 4D STEAM TRACING TYPE S STEAM TRACING TYPE S1 STEAM TRACING TYPE S2 ELECTRIC TRACED STEAM JACKETING (FULL JACKETING) STEAM JACKETING (SEMI JACKETING) COLD INSULATION (REDUCTION OF HEAT GRAIN / CONDENSATION CONTROL TYPE 5) COLD INSULATION (REDUCTION OF HEAT GRAIN / CONDENSATION CONTROL TYPE 6) SOUND CONTROL (REDUCTION OF HEAT GRAIN / CONDENSATION CONTROL TYPE 8A) SOUND CONTROL (REDUCTION OF HEAT GRAIN / CONDENSATION CONTROL TYPE 8B) SOUND CONTROL (REDUCTION OF HEAT GRAIN / CONDENSATION CONTROL TYPE 8C) SOUND CONTROL (REDUCTION OF HEAT GRAIN / CONDENSATION CONTROL TYPE 8D) INTERMITTENT OPERATION PERSONAL PROTECTION
OPE. TEMP

N:
O: P: Q: R: S: T: U: V:

ALLOY 825 VALVE TRIM


OUTER PIPE FOR JACKTED PIPE B31.8 (UP TO PIG RECEIVER) B31.8 (UP TO SLUG CATCHER) FLARE LINED STRESS RELIEVE (NACE) LNG LOADING / RUNDOWN B31.1

W:
X: Y: 1: 2: 3: 4: 5: 6:

WET GAS FLARE(26" AND AVOBE) ALLOY 625 VALVE TRIM


ABOVE GROUND UNDER GROUND DESIGN PRESSURE UP TO 25 BARG (FOR 3R1B) DESIGN PRESSURE UP TO 35 BARG (FOR 3R1B) DESIGN PRESSURE UP TO 46 BARG (FOR 3R1B) DP=19.0 Barg & DT=200 deg C (for Condensate Pump Discharge System) DP=10.4 Barg & DT=93 deg C (for Line No. MR2406101, 24K0601 Suction) Apply Dual Grade Stainless Steel 304/304L for Flanges only

61(21)400 61400 21400 21400 21400 21400 21400 21400 21400 38250 38250 38250 38204 38204 38204 -17220 -170-81

REMARKS Spec table 538MAX. TEMPERATURE 21450 61450 538MAX. TEMPERATURE 21450 538MAX. TEMPERATURE 21450 538MAX. TEMPERATURE 21450 538MAX. TEMPERATURE 21450 538MAX. TEMPERATURE 21450 538MAX. TEMPERATURE 21450 538MAX. TEMPERATURE 21450 538MAX. TEMPERATURE 38250 538MAX. TEMPERATURE 38250 538MAX. TEMPERATURE 38250 538MAX. TEMPERATURE 38204 538MAX. TEMPERATURE 38204 538MAX. TEMPERATURE 38204 100MAX. TEMPERATURE -18020 APPLIED FOR LNG LOADING -180-81 LINE ON THE JETTY COURSEWAY. -18020 -18020 -18020 -18020 -18020

2. LINE IDENTIFICATION NG YY ZZ XXX - -24"(6R1B) - 5 5 (-40) (25) ZZ XXX 24" (6R1B) - (-40)(25) INSULATION THICKNESS (MM) NORMAL OPERATING TEMP. INSULATION TYPE PIPING SERVICE CLASS LINE SIZE LINE SERIAL NUMBER UNIT CODE SYSTEM CODE LINE SERVICE CODE JACKETED LINE SLYYZZXXX- 6"(1T3J)-JF ( )- 8" ( ) ( ) INSULATION THICKNESS (MM) OUTER PIPE OPERATING TEMP. OUTER PIPE SIZE INNER PIPE OPERATING TEMP. INNER PIPE SIZE

FW: HF: LF: VENT AV:

18 19 20

8A 8B 8C 8D 9

-17020 -17020 -17020 -17020 20 -10

ATMOSPHERIC VENT

WATER BR: BRINE DRAIN CS: CHEMICAL CONTAMINATED WATER NS: CAUSTIC WASTE WATER NW: NON CONTAMINATED WATER OW: OILY CONTAMINATED WATER SY: SANITARY SEWER WW: WASTE WATER

5. INSULATION TYPE
N: 1: 2: 3A: 3B: 3C: 4A: 4B: 4C: 4D: 5: 6: 8: 8A: 8B: 8C: 8D: NON-INSULATION HEAT CONSERVATION PERSONNEL PROTECTION (ABOVE 61) HEAT CONSERVATION WITH CLASS A SOUND CONTROL HEAT CONSERVATION WITH CLASS B SOUND CONTROL HEAT CONSERVATION WITH CLASS C SOUND CONTROL CLASS A SOUND CONTROL CLASS B SOUND CONTROL CLASS C SOUND CONTROL CLASS D SOUND CONTROL REDUCTION OF HEAT GAIN CONDENSATION CONTROL REDUCTION OF HEAT GAIN CONDENSATION CONTROL (LOADING LINE ON JETTY COURSEWAY) ACOUSTIC INSULATION FOR COLD SERVICE REDUCTION OF HEAT GAIN CONDENSATION CONTROL WITH CLASS A SOUND CONTROL REDUCTION OF HEAT GAIN CONDENSATION CONTROL WITH CLASS B SOUND CONTROL REDUCTION OF HEAT GAIN CONDENSATION CONTROL WITH CLASS C SOUND CONTROL REDUCTION OF HEAT GAIN CONDENSATION CONTROL WITH CLASS D SOUND CONTROL PERSONNEL PROTECTION FOR COLD SERVICE (BELOW -10C) OR CONDENSATION CONTROL LP STEAM TRACING MP STEAM TRACING LP STEAM TRACING (DUAL INSULATION) ELECTRICAL HEAT TRACING STEAM JACKETING (FULL) STEAM JACKETING (SEMI) 21 22

8. TEST FLUID
H: P: S: V: HYDROSTATIC (WATER) PNEUMATIC (AIR) SERVICE TEST VISUAL INSPECTION

4. PIPING SERVICE CLASS


R BS1 3 R 33 B S 1 SUFFIX2 (AS REQUIRED) SUFFIX1 (AS REQUIRED) MATERIAL CORROSION ALLOWANCE SERVICE PRESSURE TEMPERATURE ASME CLASS

9. INSPECTION REQUIREMENTS
RT: RADIOGRAPHIC EXAMINATION PT: LIQUID PENETRANT EXAMINATION MT: MAGNETIC EXAMINATION UT: ULTRASONIC EXAMINATION INSPECTION REQUIREMENTS SUMMARY REFER TO TABLE-1,2 AND TABLE-3.

3. LINE SERVICE CODE PROCESS FLUID


PROCESS GENERAL A: AIR AG: ACID GAS BT: BUTANE DG: DEFROST GAS ET: ETHANE GL: NATURAL GAS LIQUID HG: HELIUM LG: LIQUEFIED NATURAL GAS LP: LIQUEFIED PETROLEUM GAS NG: NATURAL GAS OX: OXYGEN P: GENERAL PROCESS PP: PROPANE PC: PROCESS CONDENSATE PW: PROCESS WATER RS: RECOVERED SLOPS SU: SOUR CONDENSATE SL: LIQUID SULFER

UTILITY FLUID
AIR IA: SA: INSTUMENT AIR SERVICE AIR

10. P.W.H.T. AND HARDNESS


PWHT: POST WELD HEAT TREATMENT YES : REQUIRED NO : NOT REQUIRED - : NOT APPLICABLE

NITROGEN N: NITROGEN NL: LIQUID NITROGEN STEAM / CONDENSATE HS: HIGH PRESSURE STEAM HHS: HIGH HIGH PRESSURE STEAM MS: MEDIUM PRESSURE STEM LS: LOW PRESSURE STEAM CC: CONTAMINATE (SUSPECT) CONDENSATE SC: STEAM CONDENSATE SCC: COLD CONDENSATE SCH: HP STEAM CONDENSATE SCL: LP STEAM CONDENSATE SCM: MP STEAM CONDENSATE SCT: TURBINE CONDENSATE

PRESSURE TEMPERATURE ASME CLASS 1: ASME CLASS 150 3: ASME CLASS 300 6: ASME CLASS 600 9: ASME CLASS 900 X: ASME CLASS 1500 SERVICE A: AIR NITROGEN C: SOUR / CORROSIVE PROCESS J: HYDROCHLORIC ACID, SODIUM HYPOCHLORIDE P: GENERAL PROCESS R: LOW TEMPERATURE PROCESS S: STEAM T: LIQUID SULFUR CONTAINED W: WATER Y: LUBE OIL SEAL OIL

9: S: S1: S2: E: JF: JS:

11. DESIGN CONDTIONS AND OPERATING CONDITIONS


1) (1) (2) (3) 2) (1) (2) (3) DESIGN CONDITION DESIGN CONDITION ALT. DESIGN CONDITION-1 ALT. DESIGN CONDITION-2 OPERATING CONDITION OPERATING CONDITION ALT. OPERAT. CONDITION-1 ALT. OPERAT. CONDITION-2 :LONG TERM CONDITION AND BASIS FOR PIPING COMPONENTS DESIGN :SHORT TERM CONDITION SUCH AS DEPRESSURING, START-UP, SHUT DOWN etc. :SHORT TERM CONDITION SUCH AS DEPRESSURING, START-UP, SHUT DOWN etc.

FOR SOUND CONTROL APPLICATIONS, THE INSULATION TYPE SHALL BE APPENDED WITH A *CLASS SUFFIX*(A,B,C OR D). THE CLASS SUFFIX IDENTIFIES THE REQUIRED NOISE REDUCTION FOR THE SPECIFIC SYSTEM.

:NORMAL OPERATING CONDITION :ALTERNATE OPERATION SUCH AS REGENERATION etc. :ALTERNATE OPERATION SUCH AS REGENERATION etc.

12. CODE
BLANK : ASME B31.3 : PROCESS PIPING B31.1 : ASME B31.1 : POWER PIPING B31.8 : ASME B31.8 : GAS TRANSMISSION AND DISTRIBUTION SYSTEM "D" : ASME B31.3 CATEGORY "D"FLUID SERVICE

1/4

LINE LIST ABBREVIATION-2

13.Note Note1)Loss of Feed Demonstration of the piping stress analysis at the Loss of Feed Case for most sever line/nozzle between Sub-Cooler nozzle X and Expander outlet nozzle was carried out to confirm its effect, in accordance with joint meeting among QGll, APCI and CTJV. (See Attachment-3) The piping loads on compander are confirmed by APCI and its acceptable. (See Attachment-4) Further demonstration of piping stress analysis at the Loss of Feed Case for other relevant piping will not be required, since the effects of Loss of Feed Case are confirmed and acceptable as above. (See Attachment-5) Note2) Severe cyclic condition shall be applied to specific piping components or joints in which S E computed in accordance with ASME B31.3 319.4.4 exceeds 0.8SA , and the equivalent number of cycles (N) exceeds 7000. N=equivalent number of full displacement cycles during the expected service life of the piping system.

2/4

TABLE-1
INSPECTION REQUIREMENTS FOR P1 AND P8 WELDS (REFER TO PARAGRAPH.12.6)
(PARAGRAPH NUMBERS REFER TO B31.3 UNLESS OTHERWISE INDICATED)

TABLE-2
INSPECTION REQUIREMENTS FOR WELDS OTHER THAN P-1 AND P-8
(PARAGRAPH NUMBERS REFER TO B31.3 UNLESS OTHERWISE INDICATED.)

WELD TYPE

Non-Low Temperature/ Non-Cryogenic Service (P-1) , (P-8) & (S-1)


PRESSURE CLASS PRESSURE CLASS 600 AND LOWER 900 AND HIGHER A,D

Low Temperature Service (P-1), (P-1 + P-8)(clad) & (S-1 + P-8)(clad)

Cryogenic Service (P-8)

Austenitic Steels & Miscellaneous Metals (P-7, P-21 to P-25, P-34, P-42, P-44 & P-45 )
WELD TYPE PRESSURE CLASS 600 & LOWER RT (INCLUDING MITER WELDS) AND INSERT-TYPE CONTOURED A,C PRESSURE CLASS 900 & HIGHER A,D

Low-Alloy Steels (P-3, P-4, P-5, P-6, P-9A, P-9B, P-10, P-10A, P-10E AND P-11A)
PRESSURE CLASS 600 & LOWER A,C,F PRESSURE CLASS 900 & HIGHER A,D,F

PRESSURE CLASS PRESSURE CLASS PRESSURE CLASS PRESSURE CLASS 300 AND LOWER A,C 600 AND HIGHER A,D A,C,F 150 300 AND HIGHER A,D,F

GIRTH BUTTWELDS (INCLUDING MITER WELDS) PIPE TO PIPE BRANCH CONNECTIONS (INCLUDING REINFORCING PADS) AND BRANCHES MADE WITH O-LET FITTINGS AND PIPE COUPLINGS OTHER PRESSURE CONTAINING FILLET WELDS (SOCKET WELDS, SEAL WELDS, SLIP-ON, FLANGE WELDS,ETC) ATTACHMENT WELDS TO PRESSURE PARTS (NON-PRESSURE CONTAINING WELDS) Welds of contoured-insert-type connection (Contoured Outlet) Girth buttwelds-UG water piping

A,B

A,F

A,E

A,E

A,E

A,F

A,E

BRANCH FITTING WELDS [NOTE-1] LONGITUDINAL BUTTWELDS [NOTE 2] PIPE-TO-PIPE BRANCH A,E A,E A,E A,E A,D A,D A,D,F A,D,F

A,F

A,F

A,F

A,F

CONNECTIONS (INCLUDING REINFORCING PADS) AND BRANCHES MADE WITH O-LET

A,F

A,F

A,F

A,F

FITTINGS AND PIPE COUPLING [NOTE 3] PRESSURE-CONTAINING FILLET WELDS A A,F A,F A,F

A,D AG

A,D

A,D

A,D

A,D

A,D

(SOCKET WELDS, SEAL WELDS, SLIPON FLANGE WELDS, ETC.) STRUCTURAL ATTACHMENT WELDS (NON-PRESSURE CONTAINING B A A,F A,F

AB-

100% visual examination of all welds per Paragraph 344.2 Minimum 5% of random radiographic examination (RT) or ultrasonic examination (UT) [Note.1]. If the weld reject ratio exceeds 5%, RT or UT shall be increased to 100% and shall stay at 100% until the reject rate drops below 5% and stays there for five consecutive working days. ABC-

WELDS)

Complete visual examination of all welds per Paragraph 344.2. Complete visual examination of at least 5% of all welds per Paragraph 341.1.1(a). Random radiographic examination (RT) or ultrasonic examination (UT) per Paragraph 341.4.1(b) [Note 4]. If the weld reject ratio exceeds 5%, RT or UT shall be increased to 100% and shall stay at 100% until the reject rate drops below 5% and stays there for five working consecutive days.

C-

Minimum 10% of random RT or UT [Note.1]. If the weld reject ratio exceeds 5%, RT or UT shall be increased to 100% and shall stay at 100% until the reject rate drops below 5% and stays there for five consecutive working days.

DE-

100% RT or UT per Paragraph 341.4.1 of B31.3 and Paragraph 12.8 (d) of this specification. 100% Magnetic particle (MT) or dye penetrant (PT) examination (final pass and root pass). (See Paragraph 344.3 and 344.4). [Note.2]. DE-

100% RT or UT per Paragraph 341.4.1 of B31.3 and Paragraph 12.8(d) of this specification. 100% Magnetic particle or dye penetrant examination (final pass and root pass). (See Paragraphs 344.3 and 344.4.)

F-

100% MT or PT examination (final pass only). (See Paragraph 344.3 and 344.4). [Note.2]. F-

100% Magnetic particle or dye penetrant examination (final pass only). (See Paragraphs 344.3 and 344.4.)

G-

Underground water piping 100 % R.T. & 100 % M.P.I. for the first 5 welds and thereafter 20 % R.T. & 20 % M.P.I

Notes to TABLE-1 1. For random radiography, at least one weld of each welder for every material grouping he welds and weld process he uses shall be radiographed. When required random examination reveals a defect, Progressive Examination shall be applied in accordance with Paragrapf 341.3.4. 2. MT shall be applied for P-1 welds and PT shall be applied for P-8 welds. PT as the substitute of MT for P-1 welds shall be subject to APPROVAL by COMPANY. 3. For weld acceptance criteria, see Paragraph 12.8 of this specification. 4. Appendix 1 dose not apply to Category "D" fluid service. Category "D" piping shall be subject to 100% visual examination in accordance with Paragraphs 341.4.2 and 344.2. 5. When pneumatic test is APPROVAL by COMPANY, the floowing additional inspection to this Table shall be applied, as a minimum: (a) For Pressure Class 300 and Higher 100% RT for all butt welds and 100% MT or PT for final pass for all pressure retaining fillet welds regardless of piping service classes. MT shall be applied for P-1 welds and PT shall be applied for P-8 welds. (b) For Pressure Class 150 100% MT or PT for final pass for all pressure retaining welds including butt welds and fillet welds. MT shall be applied for P-1 welds and PT shall be applied for P-8 welds. The above additional requirements will not apply to the piping for instrument air, plant air and nitrogen.(Category D fluid)

Notes for TABLE-2 1. Girth Buttwelds and welds attaching insert type contoured branch fittings shall be examined by 100% radiography per paragraph 341.4.3(b) if they are in hydrogen service with a hydrogen partial pressure of 7000kPa abs (1000psia) or more, or with an operating temperature of 205(400F) or higher. 2. There requirements are not applicable to the longitudinal welds in pipe made to API specifications and to the acceptable ASTM specifications shown in QCS/50/00/MP/DB/NA/002. 3. Operating facilities with a quality assurance program that includes strict adherence to fit-up requirements may use the AF inspection requirement. 4. For random radiography, at least one weld of each welder for every material grouping he welds and weld process he uses shall be radiographed. In-process examination (paragraph344.7) may be substituted for random radiography (or ultrasonic methods) with COMPANY APPROVAL. 5. For weld acceptance criteria see paragraph 12.8 of this specification. 6. Appendix 2 does not apply to category D fluid service

3/4

TABLE-3
Service Class RATING SIZE BASIC MATERIAL P NO. SERVICE LowTemp or Cryoginic

PIPING INSPECTION REQUIREMENTS SUMMARY


NDEFOR HYDRO. TEST
Gurth Buttwelds Fillet Welds Branch Welds Attachements Welds

NDE FOR PNEUMATIC. TEST


Gurth Buttwelds Fillet Welds Branch Welds Attachements Welds

PWHT

HARDNESS TEST Service Class

RATING

SIZE

BASIC MATERIAL

P NO.

SERVICE Low-Temp or Cryoginic

NDEFOR HYDRO. TEST


Gurth Buttwelds Fillet Welds Branch Welds Attachements Welds

NDE FOR PNEUMATIC. TEST


Gurth Buttwelds Fillet Welds Branch Welds Attachements Welds

PWHT

HARDNESS TEST

1A1A 1C0JL 1C0KL 1C0N 1C1JL 1C1KL 1C3AS 1C3ASR 1C3ASV

150 150 150 150 150 150

1/2-24 1/2-52 1/2-24 1/2-12 1/2-64

KCS 304L-SS 316L-SS Incoloy 825 304L-SS 316L-SS

1 8 8 NA 8 8 1 1 1 1

NO NO NO NO NO NO NO NO YES YES

A,B A,B A,B A,C A,B A,B A,B A,B A,C A,C

A A A A A A A A A A

A,F A,F A,F A,E A,F A,F A,F A,F A,F A,F

A A A B A A A A A A

A,B,F A,B,F A,B,F A,C A,B,F A,B,F A,B,F A,B,F A,C,F A,C,F

A,F A,F A,F A A,F A,F A,F A,F A,F A,F

A,F A,F A,F A,E A,F A,F A,F A,F A,F A,F

A A A B A A A A A A

NO NO NO NO NO NO YES YES YES YES

NO NO NO NO NO NO YES YES YES YES

3R1B3

300

1/234,38 36,40-68

LTCS

YES

A,C

A,F

A,D

A,F

A,F

NO YES

NO YES YES NO NO NO YES NO NO NO

3R3BS 3S1A 3S1A4 3S1AU 3S1Y 3Y0KL 6C0JL 6C0JL6

300 300 300 300 300 300 600 600

1/2-24 1/2-46 1/2-24 1/2-14 1/2-28 1/2-8 1/2-24 1/2-24

LTCS (NACE) KCS KCS KCS (B31.1)


LOW ALLOY (1.1/4CR1/2MO)(B31.1)

1 1 1 1 4 8 8 8

YES NO NO NO NO NO NO NO

A,C A,B A,B A,B A,C,F A,B A,B A,B

A A A A A,F A A A

A,F A,F A,F A,F A,E A,F A,F A,F

A A A A A,F A A A

A,D A,D A,D A,D A,C,F A,D A,D A,D

A,F A,F A,F A,F A,F A,F A,F A,F

A,F A,F A,F A,F A,E A,F A,F A,F

A A A A A,F A A A

YES NO NO NO YES NO NO NO

1/2-16 150 150 150 1/2-72 1/2-74 1/2-24 26-74 KCS (NACE) KCS (NACE) LTCS (NACE) KCS (NACE) KCS (NACE) KCS (NACE) HAST KCS KCS KCS
LOW ALLOY (1.1/4CR-1/2MO)

316L-SS 304L-SS 304/304L-SS

1C4AS 1C6AS 1J0M 1P1A 1P1AR 1P3A 1P3Y 1R0JL 1R0JL5 1R0JLR 1R1B 1R1BR 1R3BS 1R3BSR 1S1A 1T3AJ 1T3AO 1T6ASJ 1T6ASO 1W0WA 1W0WC

150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150

1/2-24 1/2-60 1/2 - 6 1/2-54 1/2-58 1/2-80 1/2-70 1/2-78 1/2-78 1/2-78 1/2-82 1/2-80 1/2-70 1/2-70 1/2-100 1/2-14 1/2-18 1/2-60 1/2-64 1/2-24 1/2 - 4 6-24

1 1 44 1 1 1 4 8 8 8 1 1 1 1 1 1 1 1 1 1 34 1 34 NA 1 34 NA 1 1 1 1 8 8 8 8 8 1 1 1 1

NO NO NO NO NO NO NO YES YES YES YES YES YES YES NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO

A,B A,B A,C A,B A,B A,B A,C,F A,C F A,C,F A,C,F A,C A,C A,C A,C A,B A,B A,B A,B A,B A,B A,C A,C A,B A,C A,B A,B A,B A,B A,B A,B A,B A,B A,B A,B A,B A,B A,B

A A A A A A A,F A,F A,F A,F A A A A A A A A A A A A A A A A A A A A A A A A A A A A

A,F A,F A,E A,F A,F A,F A,E A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,E A,F A,E A,F A,E A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F

A A B A A A A,F A,F A,F A,F A A A A A A A A A A B A B A B A A A A A A A A A A A A A

A,B,F A,B,F A,C A,B,F A,B,F A,B,F A,C,F A,C F A,C,F A,C,F A,C,F A,C,F A,C,F A,C,F A,B,F A,B,F A,B,F A,B,F A,B,F A,B,F A,C A,C A,B,F A,C A,B,F A,B,F A,B,F A,B,F A,B,F A,B,F A,D A,D A,D A,D A,D A,D A,D

A,F A,F A A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A A,F A A,F A A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F

A,F A,F A,E A,F A,F A,F A,E A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,E A,F A,E A,F A,E A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F

A A B A A A A,F A,F A,F A,F A A A A A A A A A A B A B A B A A A A A A A A A A A A A

YES YES NO NO NO NO YES NO NO NO NO NO YES YES NO NO NO YES NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO YES YES YES NO YES

YES YES NO NO NO NO YES NO NO NO NO NO YES YES NO NO NO YES NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO YES YES YES NO YES NO NO YES NO NO NO NO NO YES

6C0KL 6C3AS 6C3ASB

600 600 600

1/2-16 1/2-46 1/2-2 3-24

316L-SS KCS (NACE) KCS (NACE) LTCS (NACE) KCS (NACE) KCS (NACE) KCS

8 1 1 1 1 1 1

NO NO NO YES NO NO NO

A,B A,B A,B A,D A,B A,B A,B

A A A A,F A A A

A,F A,F A,F A,E A,F A,F A,F

A A A A,F A A A

A,D A,D A,D A,D A,D A,D A,D

A,F A,F A,F A,F A,F A,F A,F

A,F A,F A,F A,E A,F A,F A,F

A A A A,F A A A

NO YES YES YES YES YES NO YES

NO YES YES YES YES YES NO YES NO NO YES NO YES NO NO YES NO NO NO YES YES NO NO YES NO NO NO YES NO YES YES YES YES YES YES NO NO NO YES YES NO YES NO YES YES YES NO NO NO

6C4AS 6C6AS 6P1A

600 600 600

1/2-12 1/2-24 1/2-12 14-48

304L-SS 304L-SS 304L-SS LTCS LTCS LTCS (NACE) LTCS (NACE) KCS KCS KCS KCS (NACE) KCS CS-ALMNZD Cu-Ni CS-CEMENT-LND Cu-Ni FRP CS-FLAKE-LND Cu-Ni FRP CS-FLAKE-LND CS-GALV KCS KCS 304L-SS 316L-SS 304L-SS 316L-SS 304L-SS KCS (NACE) KCS (NACE) KCS (NACE) KCS

6P1AB

600

1/2-2 3-12 14-24

KCS LTCS

1 1

NO YES

A,B A,D

A A,F

A,F A,E

A A,F

A,D A,D

A,F A,F

A,F A,E

A A,F

NO NO YES

6P3A

600

1/2-12 14-40

KCS

NO

A,B

A,F

A,D

A,F

A,F

NO YES

6R0CM

900/600

1/2-10 12-24 26-56

SS-316L SS-316L/LTCS with 316L-SSCLAD 304L-SS 304/304L-SS LTCS

8 1

YES YES

A,D,F A,D

A,F A,F

A,E A,E

A,F A,F

A,D,F A,D

A,F A,F

A,E A,E

A,F A,F

NO NO YES

6R0JL 6R0JL6 6R1B

600 600 600

1/2-48 1/2-48 1/2-12 14-54

8 8 1

YES YES YES

A,D,F A,D,F A,D

A,F A,F A,F

A,E A,E A,E

A,F A,F A,F

A,D,F A,D,F A,D

A,F A,F A,F

A,E A,E A,E

A,F A,F A,F

NO NO NO YES

6R3BS 6S1A 6S1AU

600 600 600

1/2-48 1/2-12 1/2-10 12

LTCS (NACE) KCS KCS (B31.1)

1 1 1

YES NO NO

A,D A,B A,B

A,F A A

A,E A,F A,F

A,F A A

A,D A,D A,D

A,F A,F A,F

A,E A,F A,F

A,F A A

YES NO NO YES

1W0WFX

150

1/2 - 4 6-24 28-102

6Y0KL 9C0CK

600 1/2-6 1500/ 900 1/2-10 12-42 44-48

316L-SS SS-316L(B31.8) CS with SS-316L CLAD(B31.8) 304L-SS KCS(B31.8) (NACE) KCS(B31.8) (NACE) KCS (NACE) KCS (NACE) LTCS (NACE) KCS (NACE) KCS SS-316L SS-316L/LTCS with 316L-SSCLAD LTCS (NACE) KCS

8 8 1

NO NO NO

A,B A,D

A A,F

A,F A,E

A A,F

A,D A,D A,D

A,F A,F A,F

A,F A,E A,E

A A,F A,F

NO NO NO YES t;31.75 mm Over NO YES YES YES YES YES YES NO NO NO YES

1W0WFY

150

1/2 - 4 6-24 28-102

1W0WG 1W3AX 1W3AY 1Y0JL 1Y0KL 3C0JL 3C0KL 3C1JL 3C3AS 3C4AS 3C6AS 3P1A

150 150 150 150 150 300 300 300 300 300 300 300

1/2-10 1/2-114 1/2-114 1/2-24 1/2-24 1/2-32 1/2-24 1/2-24 1/2-32 1/2-24 1/2-24 1/2-38 40 - 42

9C0JL 9C3AP 9C3AQ 9C3AS 9C3ASB

900 900 900 900 900

1/2-30 1/2-38 1/2-48 1/2-30 1/2-2 3-24

8 1 1 1 1 1 1 1 8 1

NO NO NO NO NO YES NO NO YES YES

A,D A,D A,D A,D A,D A,D A,D A,D A,D,F A,D

A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F

A,E A,E A,E A,E A,E A,E A,E A,E A,E A,E

A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F

A,D A,D A,D A,D A,D A,D A,D A,D A,D,F A,D

A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F

A,E A,E A,E A,E A,E A,E A,E A,E A,E A,E

A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F

9C4AS 9P1A 9R0CM

900 900 900/600

1/2-14 1/2-2 1/2-10 12-14 16-48

9R3BS 9S1A

900 900

1/2-46 1/2-10 12-36

1 1

YES NO

A,D A,D

A,F A,F

A,E A,E

A,F A,F

A,D A,D

A,F A,F

A,E A,E

A,F A,F

YES NO YES

3P1AB

300

1/2-2 3-34 36-42

KCS LTCS

1 1

NO YES

A,B A,C

A A

A,F A,F

A A

A,D A,D

A,F A,F

A,F A,F

A A

NO NO YES

9S1AU

900

1/2-10 12-36

KCS (B31.1)

NO

A,D

A,F

A,E

A,F

A,D

A,F

A,E

A,F

NO YES

3P3A 3R0JL 3R0JLT 3R1B1 3R1B2

300 300 300 300 300

1/2-36 1/2-66 1/2-40 1/2-68 1/2-50 52-68

KCS 304L-SS 304L-SS LTCS LTCS

1 8 8 1 1

NO YES YES YES YES

A,B A,D,F A,D,F A,C A,C

A A,F A,F A A

A,F A,E A,E A,F A,F

A A,F A,F A A

A,D A,D,F A,D,F A,D A,D

A,F A,F A,F A,F A,F

A,F A,E A,E A,F A,F

A A,F A,F A A

NO NO NO NO NO YES

9S1Y 9S1YU 9Y0KL XC0KL XY0KL

900 900 900 1500 1500

1/2-44 1/2-24 1/2-6 1/2-30 1/2-6

LOW ALLOY (1.1/4CR1/2MO) LOW ALLOY (1.1/4CR1/2MO)(B31.1)

4 4 8 8 8

NO NO NO NO NO

A,D,F A,D,F A,D A,D A,D

A,F A,F A,F A,F A,F

A,E A,E A,E A,E A,E

A,F A,F A,F A,F A,F

A,D,F A,D,F A,D A,D A,D

A,F A,F A,F A,F A,F

A,E A,E A,E A,E A,E

A,F A,F A,F A,F A,F

YES YES NO NO NO

316L-SS 316L-SS 316L-SS

4/4

Line List for Unit 83 (System No. : 59)


Client : Project : Job No. : Doc No. :

7 of 7

Qatar Liquefied Gas Compagny Limited Qatargas 3&4 onshore Project


QCS/59/83/FF/LI/NA/702 Full Vacuum Special Cleaning Alternate Operating Condition Press
Bar g

Revision No.

Density

System Code

Fluid Code

Unit Code

Line Size Seq o.

Class Thk. Code mm

P&ID Dwg. No. From To

Paint Code

Defrosting

Insulation

PWHT

Remarks Press RT UT A A A A A A A A A A A A A A A A PT A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F A,F MT A A A A A A A A A A A A A A A A Pack No. Medium
Bar g

Press
Bar g

Temp
Deg C

Temp
Deg C

Press
Bar g

Temp
Deg C kg/m3

Press
Bar g

Temp
Deg C

Press
Bar g

Temp
Deg C

Press
Bar g

Temp
Deg C

@ Deg C

E2 E1 E1 E1 E1 E1 E1 E2 E1 E1 E1 E1 E1 E1 E1 E1

FW FW FW FW FW FW FW FW FW FW FW FW FW FW FW FW

59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59

83 83 83 83 83 83 83 83 83 83 83 83 83 83 83 83

001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016

14" 8" 14" 8" 8" 8" 14" 14" 8" 8" 8" 8" 8" 8" 6" 6"

1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC 1W0WC

N N N N N N N N N N N N N N N N

QCS-59-83-FF-DR-PL-526 QCS-59-83-FF-DR-PL-526 QCS-59-83-FF-DR-PL-526 QCS-59-83-FF-DR-PL-526 QCS-59-83-FF-DR-PL-526 QCS-59-83-FF-DR-PL-526 QCS-59-83-FF-DR-PL-526 QCS-59-83-FF-DR-PL-528/529 QCS-59-83-FF-DR-PL-528 QCS-59-83-FF-DR-PL-528 QCS-59-83-FF-DR-PL-527 QCS-58-83-FF-DR-PL-525 QCS-58-83-FF-DR-PL-525 QCS-59-83-FF-DR-PL-527 QCS-59-83-FF-DR-PL-526 QCS-59-83-FF-DR-PL-526

TIE-IN T-QS-8305 TIE-IN T-QS-8304 TIE-IN T-QS-8303 FW5983002 FW5983002 FW5983001 FW5983001 FW5983007 FW5983008 FW5983008 FW5283013 FW5283013 FW5383001 FW5983009 FW5983002 FW5983001

FW5983007 FW5983007 FW5283004 FW5283003 FW5283003 FW5983002 FW5283003 FW5983010 FW5983014 FW5983014 FW5983014 FW5983014 FW5983014 FW5983013 FW5983005 FW5983006

L L L L L L L L L L L L L L L L

9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3

35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35

994 994 994 994 994 994 994 994 994 994 994 994 994 994 994 994

12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12

45 45 45 45 45 45 45 45 45 45 45 45 45 45 82 82

N N N N N N N N N N N N N N N N

AA AA AA AA AA AA AA AA AA AA AA AA AA AA 1C 1C

NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO

H H H H H H H H H H H H H H H H

18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18

Flex. Grade

Fluid Phase

Line Number

Line Connection

XX Bar g @ XX Deg C

Operating Condition

Alternate 2 Operating Condition

Design Condition

Alternate Design Condition

Alternate 2 Design Condition

NDE (%)

Pressure Test

You might also like