ICS 07. 060;67. 260
A45
HY
FR eX Be SE 0 Be) is FF TT ML eR HE
HY/T 064—2002
@ st i A th FL Wik BK
Test methods for tubular ceramic microporous filtration membrane
2002-12-30 & 7h 2003-02-01 3c 6
BRBER 2Y/T 064—2002
AR PRMEMUIH SR A RL RHE MOTTE.
ARE AYR BRAS HY HAR
ARE FT th ee
Zh SOS eh POA,
AARNE EAL OR LKB ERA LAB A RA
ARE ERA ABLE I HE I RHHE AR AT RE
FRMAMA MMA HK HY/F 064—2002
‘Test methods for tubular ceramic microporous filtration membrane
1 3H
AERA T EA AMSA OTL OM RAIL ACE ,
SE SITLL BRM A rH BRE LD HS IH IMR
ACHR MER FAT AE SRS LUE RC
2 3 Rte
TB BUR ME DT C2 BO RIC Le AE 1 A TAR REY AR, ACRE RL» RASS I
FL FRAG ARMA Se BRA TT 8 FV PAE OS 3 WA 9 TH
GB/T 1966-1996 A>FL RUBE UALR A RR tk
GB 17323-1998 HEE OCR a
3 BM
AREAL FE
3.1 FRE dry membrane
FRR ALR HF TS EY RE TL
3.2 SBA wet membrane
FRR HS FA FE FP BG YO HE ATL EH
4 SERA
ADD: ALE AH STA.
—— Siok 8% GB 17323 SRB ER.
—— if NaOH.
RIE 98% HR.
—— FT.
—— FAR.
——— RETR ALO. 1 ET RA,
—— FRE ARIAL «1 6 BK a a
5 hase
RE EH 0.001 g
TLR ABE 1 keg RAR 0.01 ge
RE.
TAA TRA: (0~300)C.
FRR AEH 2002-12-30 Ht HE 2003-02-01 3e M6
1