You are on page 1of 2

JOB TITLE: JOB NO.: CALCULATED BY: CHECKED BY: SHEET NO.

: DATE: DATE:

8/8/2011

AASHTO-LRFD 2004 - CONCRETE SLAB & WALL DESIGN


LOCATION OF DESIGN SECTION: FLEXURE CHECK: Factored Moment, Mu = Service Moment, Ms = Concrete Strength, f'c = Yield Strength, fy = Total Depth, t = Effective Width, b = 1st Bar Set Size = 1st Bar Set Spacing = 2nd Bar Set Size = 2nd Bar Set Spacing = Average Bar Spacing = Reinforcing Bar Area = Clear Cover = Effective Depth, de = 20.51 k-ft 16.49 k-ft 4.50 ksi 60.00 ksi 16.00 in 12.00 in #6 8.00 in None 0.0 in 8.00 in 0.66 si 2.63 in 13.00 in Some Location SHEAR CHECK: Vu Max = Mu @ Vu Max = Shear = 15.55 kips 20.51 k-ft 0.9

b=12" 1st Bar Set 2nd Bar Set t = 16"

Clr = 2.625"

Concrete Section
STRENGTH DESIGN CAPACITY: = = a= 0.9 0.65 0.86 Mn = AsFy(d-a/2) in Mn = 37.33 k-ft OK

MAXIMUM REINFORCING CHECK: Max = 0.02 As Max = 2.71 si OK

MINIMUM REINFORCING CHECK: S5.4.2.6 S5.7.3.3.2-1 fr = S= Mcr = 0.509 512 21.72 ksi in^3 k-ft Mr Lesser of:

Mr = Shrink. & Temp. Steel, As min. = As Prov. =

1.2 x Mcr = 1.33 x Mu =

26.07 27.28 37.33 0.35 0.66

k-ft k-ft k-ft si si

S5.7.3.3.2(a) S5.7.3.3.2(b)

OK
S5.10.8.2

OK

CRACK CONTROL: AASHTO LRFD 5.7.3.4: Allowable Stress in Reinforcing: dc = 2.375 in A= 38.00 133 k/in Actual Stress in Reinforcing: = 0.004 n= n = k= fa = 29.655 ksi j= fs = 7.50 0.032 0.222 0.926 24.908 OK ksi

Z1 = 170 for moderate exposure conditions, Z2 = 130 for severe exposure conditions, Z3 = 100 for precast box culverts, Z4 = 155/ for cast-in-place box culverts; = 122.919 k/in
SHEAR CHECK:

Z(Input) =

Vu > Vc

Vc = 0 . 0676

V d f ' c 4 . 6 As u e bd e = bd e M u

22.38

kips

OK