Install in rack
Four-post rack
Caution: Use only the NetApp rail kit to install your system. Using a different rail kit can cause injury to you or damage to your system.
DS14mk2 or DS14mk4
0
Shelf ID switch
Note: The disk shelf IDs for the disk shelves should be set in the range 1 to 6.
(2x)
DS4243
1. Connect power cords to the shelf and turn on power. 2. Check that the shelf ID is unique and in the range 01 to 98. If not, set the ID:
!
(2x)
Shelf ID tab
See the DS4243 Installation and Service Guide at http://now.netapp.com for more details.
Front rail
a. Remove the left ear cover on the DS4243. b. Press and hold the U-shaped tab above the LEDs until the first digit blinks. c. Press the tab until the correct number is displayed. d. Repeat steps b and c for the second digit. e. Press and hold the tab until the second number stops blinking. f. Power cycle the shelf to make the new shelf ID take effect.
FRONT
SIDE
2U 3U 3U
1
Note: See the rail kit installation flyer included with the rail kit for the two-post procedure.
Connect power
Note: You do not need to ground your system.
Active/Active NAS or ISCSI: 1 SAS disk shelf stack of up to 4 disk shelves (single path)
Cable controllers
1 RJ-45 to DB-9 adapter to console port (required)
1 Controller to shelf
FAS2040
0a 0b 0d 10101 e0P e0a e0be0c e0d
1 Controller to shelf
PSU FAS2040
0a 0b 0d 10101 e0P e0a e0be0c e0d
Note: The DS4243s shown have four PSUs. Depending on drive type, it might have two.
S A S
PSU
PSU
1 Controller to shelf
FAS2040
0a 0b 0d 10101 e0P e0a e0be0c e0d
2 Shelf to shelf
FAS2040
0a 0b 0d 10101 e0P e0a e0be0c e0d
DS14
DS14
OUT IN
OUT IN
PSU
PSU
PSU
IN OUT
PSU
PSU
IN OUT
PSU
DS4243
ACP SAS
DS4243
ACP SAS
PSU
PSU
PSU
PSU PSU
IN OUT
PSU PSU
ACP SAS
S A S
PSU
IN OUT
PSU
PSU
ACP
SAS
PSU
2 Shelf to shelf
FAS2040
0a 0b 0d 10101 e0P e0a e0be0c e0d
1 Controller to switch
PSU FAS2040
0a 0b
DS4243
ACP SAS
DS4243
ACP SAS
PSU
PSU
PSU
PSU
DS14
PSU
0d
10101 e0P
PSU PSU
ACP
SAS
PSU
PSU
ACP
SAS
PSU
OUT
IN
S A S
IN
OUT
DS14
OUT
IN
3 Shelf to controller
PSU FAS2040
0a 0b 0d 10101 e0P e0a e0be0c e0d
DS14
PSU
IN OUT
PSU
OUT IN
IN OUT
PSU
PSU
PSU DS4243
ACP SAS
3 Shelf to controller
FAS2040
0a 0b 0d 10101 e0P e0a e0be0c e0d
DS4243
ACP SAS
2 Controller to shelves
PSU
e0a e0be0c e0d
PSU
PSU
PSU
PSU
S A S
8
PSU
0a 0b
0d
10101 e0P
PSU FAS2040
0a 0b 0d 10101 e0P e0a e0be0c e0d
ACP
SAS
PSU
PSU
ACP
SAS
PSU
DS14
OUT
IN
PSU DS4243
ACP SAS
IN
OUT
DS4243
ACP SAS
DS14
Port labels
Remote Management Port Fibre Channel
S A S
OUT
IN
PSU PSU
PSU
PSU
PSU
DS14
PSU
IN OUT
PSU
OUT IN
IN OUT
210-04471+A0
PSU
ACP SAS
PSU
PSU
ACP
SAS
PSU
Ethernet
Console
SAS
PSU
Trim-17 x 22
FAS2040 rear
FAS2040 front
Disk drive power and fault LEDs
Drive 0 Drive 3 Drive 11
0 to 12 disk drives System LEDs Power Fault Controller A activity Controller B activity
NVMEM status LED Fault status LED 4 network ports RM (Remote Management) port Shelf ACP port (e0P)
CAUTION
30 kg (67 lbs)
LIFTING HAZARD
Important:
For hot-swappable FRUs: Always consult http://now.netapp.com for current field-replaceable unit (FRU) replacement procedures. Adding external storage or using FC: You must order and use SFP modules on your system, if you are connecting external FC storage devices or using FC with the system.
Important:
For hot-swappable power supplies: System shuts down two minutes after you remove a power supply. Disk drive Power supply
Attention: Disk drives are fragile. Do not handle them except when replacing failed disk drives or moving them to a new chassis.
Cam handle
DIMMs Battery
4. Firmly push up the cam handle to finish seating the controller module in the system, and then push the cam handle to the closed position and tighten the thumbscrew beneath the cam handle. 5. Reattach the cable management arms by screwing them into the holes in the cam handle. 6. Complete the boot process. IF your system has a single controller module, plug in the power supply and turn on the power. IF your system is in an active/active configuration, give back the node by completing the following substeps: a. Enter the following command from the partner console: cf giveback b. On the console of the newly installed controller module, select Normal Boot (option 1) from the displayed menu to boot Data ONTAP.