Main Benets
Cover large areas at a minimised cost
Through a New Generation of GSM repeaters you will be able to cover larger areas through: Macro Base Station Output power (20W) is achieved with Avitecs repeater Reduced cost of site deployment by employing the Frequency Translating concept Quick & easy site acquisition since there is no need for line of sight between base station and repeater
Channel Selective Frequency Translating GSM900 Repeater equipped with 2 channels Channel Selective Frequency Translating GSM1800 Repeater equipped with 2 channels Channel Selective Frequency Translating GSM1900 Repeater equipped with 2 channels
CSFT91822 Channel Selective Band Shifting GSM 900 to 1800 Repeater equipped with 2 channels CSFT18922 Channel Selective Band Shifting GSM1800 to 900 Repeater equipped with 2 channels CSFT922-R Channel Selective Frequency Translating GSM-R Repeater equipped with 2 channels
CSFT
Band Shifting Technology
Operators with licenses within both GSM 900 and 1800 bands have through the Avitecs Band Shifting Repeaters the possibility to use link frequencies on the GSM1800 band, while providing coverage on the GSM900 band. Such a solutions eliminates the isolation requirement altogether, resulting in shorter masts. Installation as well as site acquisition is simplied. In other words, Capital Expenditures (CAPEX) are signicantly reduced.
Frequency Translating
A Frequency Translating EDGE Repeater provides much larger coverage than a conventional repeater does. This is due to the higher output power that is realized through decreasing the isolation requirements. As a result, a fewer number of units need to be installed and considerable cost-savings are achieved. Even omni-antennas can be used at the remote site. Frequency translation technology allows the use of an omni directional antenna at the repeater site. By shifting the frequency, the isolation requirements are reduced and lower masts can therefore be used. This also enables high output powers, in other words, large areas can be covered at a minimised cost.
F1 F9 F5 BTS Site Link Antenna FR Link Path Repeater Site
F1
F5
1. The donor unit is installed next to the base station where the signal is coupled off via a directional coupler. 2. Following frequency translation, the signals are transmitted on a link antenna and received at the remote site where signals are converted back to the original frequencies. 3. Finally, the signals are amplied in the remote unit and then transmitted on a server antenna.
Link Antenna Server Antenna
BTS
R
Donor Unit
R
Remote Unit
SD DD
The donor unit is available in two types: The Single Donor (SD) unit has one input connector. The input signal from the BTS is split up within the repeater unit. In the opposite direction in the uplink the signals are combined within the repeater before being sent to the BTS. The Double Donor (DD) unit has dual inputs. This can be used in combination with a BTS that uses air combining, and hence has a separate antenna for each TRU. A double donor unit can alternatively handle two signals from two separate BTS. The remote unit is available in two types: In an Internal combining Remote (IR) unit output from the power ampliers in the downlink is combined and ltered before being passed on to the server antenna. In the uplink the signal is separated within the remote unit. An External combining Remote (ER) unit has two server antenna ports and the signal is combined in the air. Since the ER model needs no combiner the output signal and gain is 3dB higher than in the IR model.
IR
ER
CSFT
Electrical Specication
Frequency range Uplink UL Downlink DL 900 MHz E-GSM900 880 - 915 925 - 960 900 MHz P-GSM900 890 - 915 935 - 960 900 MHz R-GSM 876 - 880 921 - 925 1710 - 1785 1805 - 1880 1850 - 1910 1930 - 1990 1800 MHz 1900 MHz
Number of channels Channel programming Selectivity, donor unit (SD and DD) Selectivity, remote unit (SD and DD) Ripple in passband Sensitivity
2 In 200 kHz Channel spacing > 60 dB at 400 kHz > 65 dB at 600 kHz > 60 dB at 400 kHz > 70 dB at 600 kHz < 2 dB < - 109 dBm at S/N 9 dB
Donor Unit (SD) and (DD) N/A 2.5 dB typical, <3 dB at max gain Donor Unit (SD) and (DD) + 23 dBm + 10 dBm
Remote Unit (IR) and (ER) 2.5 dB typical, <3 dB at max gain 2.5 dB typical, <3 dB at max gain Remote Unit (IR) and (ER) +10 dBm + 10 dBm
5.8 s typical
EDGE/8-PSK average power +34 dBm -13 dB EDGE/8-PSK average power +34 dBm -10 dB EDGE/8-PSK average power +37 dBm +34 dB EDGE/8-PSK average power +40 dBm +34 dB
Gain Donor Unit (SD) Donor Unit (DD) Remote Unit (IR) DL/UL Remote Unit (ER) DL/UL Gain Flatness (200 kHz BW) Gain Flatness (operational bandwidth) Input to Link Channel Frequency Error
max 42 dB, adjustable, in 1 dB steps max 45 dB, adjustable, in 1 dB steps 75 - 105 dB, adjustable, in 1 dB steps 78 - 108 dB, adjustable, in 1 dB steps 1 dB 1.5 dB, at constant temperature <1 x 10-9
CSFT
Modulation Accuracy
Donor Unit (SD) and (DD) DL UL Remote Unit (IR) DL UL Remote Unit (ER) DL UL GSM/GMSK < 2.5 RMS and < 10 peak at +37 dBm < 2.5 RMS and < 10 peak at -10 dBm GSM/GMSK < 2.5 RMS and < 10 peak at +40 dBm < 2.5 RMS and < 10 peak at +37 dBm GSM/GMSK < 2.5 RMS and < 10 peak at +43 dBm < 2.5 RMS and < 10 peak at +37 dBm
2005 Avitec AB
EDGE/8-PSK < 3.5% EVM RMS at +34 dBm average power < 3.5% EVM RMS at -13 dBm average power EDGE/8-PSK < 4% EVM RMS at +37 dBm average power < 3.5% EVM RMS at +34 dBm average power EDGE/8-PSK < 4% EVM RMS at +40 dBm average power < 3.5 EVM RMS at +34 dBm average power
< -36/-30* dBm (two carriers at +37 dBm DL,600 kHz spacing) < -70 dBm (two carriers at -10 dBm UL, 600 kHz spacing) < -36/-30* dBm (two carriers at +40 dBm DL, 600 kHz spacing) < -36/-30* dBm (two carriers at +37dBm UL, 600 kHz spacing) < -36/-30* dBm (two carriers at +43 dBm DL, 600 kHz spacing) < -36/-30* dBm (two carriers at +37 dBm UL, 600 kHz spacing)
* The value is -36 dBm for 900MHz and -30 dBm for 1800 and 1900 MHz Spurious emissions < - 36 dBm for 9 kHz - 1 GHz < - 30 dBm for 1 GHz - 13 GHz System impedance 50 Antenna connectors DIN 7/16 Female Base Station connector (Donor unit only) N-type Electrical ratings 110/230 V AC, 50/60 Hz (alt. - 48 VDC) Power Consumption
Frequency 900 MHz 1800 & 1900 MHz CSFT91822 CSFT18922 Donor Unit 110 W 150 W 150 W 110 W Remote Unit 200 W 240 W 200 W 220 W
Mechanical Dimensions Enclosure Weight Environmental EMC Operating Temperature Storage Humidity MTBF Complies with
540 x 350 x 150 mm (per unit) Aluminium (IP 65) 22 kg (per unit)
See compliance below - 25 to + 55 C - 30 to + 70 C ETSI EN 300 019-2-4 (see compliance below) > 100 000 hrs R & TTE Directive including: ETS EN 301 502 (ETS EN 300 609-4/GSM 11.26) ETS EN 301 498-8 EN 60 950
AVITEC AB, Address: Box 20116, S-161 02 BROMMA, SWEDEN Phone:+46-8-475 47 00 Fax:+46-8-475 47 99 E-mail: info@avitec.se