You are on page 1of 16

Theory of Operation...

Magnetic Proximity Sensors

Fig. 1 Magnetic proximity sensor makeup

About Magnetic Proximity Sensors As with inductive proximity sensors, magnetic proximity sensors have an LC oscillating circuit, a signal strength indicator and a switching amplifier. They also have a core (strip) made of amorphous, highly permeable and magnetically soft glass-metal. This strip attenuates the oscillating circuit using eddy-current losses. The core quickly becomes magnetically saturated very quickly if a magnetic field is applied, e.g., if a magnet is brought closer. The eddy-current losses attenuating the oscillating circuit are reduced and the oscillating de-attenuates. The power consumption of a magnetic proximity sensor therefore increases as a magnet is brought closer, in contrast to inductive proximity sensors where the power consumption reduces as the switching trigger is brought closer. A major advantage of this technology is that large sensing ranges are possible even with small sensor types. Permanent magnets are usually used to trigger magnetic proximity sensors. They comprise magnetically hard substances, such as steel alloyed with other metals such as aluminum, cobalt and

nickel. Magnetically hard ferrite with similar properties can also be produced from sintered compounds containing iron oxide and other metal oxides.

sn U

Fig. 2 Attenuated vs. unattenuated materials

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

826

Magnetic Proximity Sensors...Type Code


Character 1 M 1 Sensor technology M Magnetic 2 Q 3 4 1 O 5 6 6 7 8 O A 9 P 10 11 12 13 14 S K U O Character

other codes Connection W Cable, PVC U Cable, PUR-PVC T Connector, M8x1 C Connector, M12x1

14 13

Design H Barrel M Cylinder with thread Q Cuboid

3/4

Housing size 08 Diameter 10 or 12 edge length of 18 sensing face

Housing material Z Ms, nickel-plated K Plastic

12

6/7/8 Sensing range/ magnetic field 60 In mm relative to 70 stand. magnet M4.0 A Axial

Output S NO N NAMUR

10

Interface P DC (3-wire) PNP N DC (3-wire) NPN NAMUR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

827

Magnetic Proximity Sensors


Sensors MM 08 MM 12 MM 12 NAMUR MM 18 adv. MM 18 NAMUR MQ 10 adv. Page 830 832 834 836 838 840

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

828

Magnetic Proximity Sensors

DC

AC

AC

DC

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

829

MM 08 Advanced
Magnetic Proximity Sensors Highlights

Sensing range up to 60 mm
DC

PNP output High switching frequency Short-circuit protection (pulsed)

Robust brass housing, nickel-plated with fine thread M12 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator

MM 08 Advanced

Dimensional Drawing dimensions in inches (mm)

Accessories Cables and connectors Magnets

page 908 978, 979

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

830

Technical data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Selection Table Sensing range Sn in (mm)
2.4 (60) 2.4 (60)

10...30 V DC 10% of Ub 1.5 V with Ia max. 10 mA 300 mA 2 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Brass, nickel-plated, plastic 7.0 Nm PUR-PVC, 3 x 0.25 mm2

Magnetic alignment
Axial Axial

Switching output
PNP PNP

Output function

Switching frequency f in Hz
5000 5000

Connection type

Type

Part no.

Cable 2 m Connector M8 x 1 mm

MM08-60APS-ZU0 MM08-60APS-ZT0

7 900 264 7 900 266

Sensing Ranges Magnet type


M 1.0 M 2.0 M 3.0 M 4.0 M 5.0/5.1

Sensing Range sn Any installation type (flush or non-flush) in a non-magnetizable material


0.9 in (23 mm) 0.9 in (24 mm) 1.4 in (36 mm) 2.4 in (60 mm) 2.7 in (68 mm)

Sensing Range sn Flush installation in a magnetizable material (e.g. iron)


0.5 in (12 mm) 0.4 in (10 mm) 0.6 in (15 mm) 0.8 in (20 mm) 1.0 in (25 mm)

Connection Diagram

PNP

bn bk bu

1 4 3

+ DC -

NPN

bn bk bu Wire color

1 4 3 Contact brown black blue 1 4 3

+ DC Assignment + V DC NO - V DC
831

4 1 3

bn bk bu

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

MM 12 Advanced
Magnetic Proximity Sensors Highlights

Sensing range up to 60 mm
DC

PNP output High switching frequency Short-circuit protection (pulsed)

Robust brass housing, nickel-plated with fine thread M12 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator

MM 12 Advanced

Dimensional Drawing dimensions in inches (mm)

Accessories Cables and connectors Mounting brackets Magnets

page 909 925 978, 979

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

832

Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable 10...30 V DC 10% of Ub 1.5 V with Ia max. 10 mA 300 mA 2 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Brass, nickel-plated, plastic 7.0 Nm PUR-PVC, 3 x 0.25 mm2

Selection Table Sensing range Sn in (mm)


2.4 (60) 2.4 (60)

Magnetic alignment
Axial Axial

Switching output
PNP PNP

Output function

Switching frequency f in Hz
5000 5000

Connection type

Type

Part no.

Cable 2 m Connector M12 x 1 mm

MM12-60APS-ZU0 MM12-60APS-ZC0

7 900 268 7 900 270

Sensing Ranges Magnet type


M 1.0 M 2.0 M 3.0 M 4.0 M 5.0/5.1

Sensing Range sn Any installation type (flush or non-flush) in a non-magnetizable material


0.9 in (23 mm) 0.9 in (24 mm) 1.4 in (36 mm) 2.4 in (60 mm) 2.7 in (68 mm)

Sensing Range sn Flush installation in a magnetizable material (e.g. iron)M


0.7 in (17 mm) 0.6 in (14 mm) 0.9 in (23 mm) 1.5 in (37 mm) 1.7 in (44 mm)

Connection Diagram

PNP

bn bk bu

1 4 3

+ DC -

NPN

bn bk bu

1 4 3

+ DC 2 3 1

Wire color bn bk bu brown black blue

Contact Assignment 1 4 3 2 + V DC NO - V DC free

4
833

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

MM 12 NAMUR
Magnetic Proximity Sensors Highlights

Sensing range up to 60 mm
DC

High switching frequency NAMUR to EN 50 227 Shielded or unshielded LED status indicator

Robust brass housing, nickel-plated with fine thread M12 x 1 mm Cable or connector Enclosure rating IP 67

MM 12 NAMUR

Dimensional Drawing dimensions in inches (mm)

Accessories Cables and connectors Mounting brackets Magnets Power supply

page 909 925 978, 979 966

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

834

Electrical and Mechanical Data Operating voltage Ub Rated voltage Un Ripple Upp Power consumption, attenuated Power consumption, unattenuated Internal capacitance Internal inductance Cable resistance Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Max. data for connecting isolating unit EN 2 EX or other approved isolating amplifier: Short circuit current Ik max No load voltage Uo Power loss Pmax Selection Table Sensing range Sn* in (mm)
2.4 (60) 2.4 (60)

5...25 V DC 8.2 V DC 5% of Ub 2.5 mA 1.0 mA 15 nF 25 H 50 w 2 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 7.0 Nm PUR-PVC, 3 x 0.25 mm2

30 mA 16 V 75 mW

Magnetic alignment
Axial Axial

Version

Output function

Switching frequency f in Hz
5000 5000

Connection type

Type

Part no.

NAMUR NAMUR

Cable 2 m Connector M12 x 1 mm

MM12-60A-N-ZW0 MM12-60A-N-ZC0

7 900 286 7 900 287

* Sensing range sn based on installation in non-magnetizable material using magnet M 4.0. Sensing Ranges Magnet type
M 1.0 M 2.0 M 3.0 M 4.0 M 5.0/5.1

Sensing Range sn Any installation type (flush or non-flush) in a non-magnetizable material


0.9 in (23 mm) 0.9 in (24 mm) 1.4 in (36 mm) 2.4 in (60 mm) 2.7 in (68 mm)

Sensing Range sn Flush installation in a magnetizable material (e.g. iron)M


0.7 in (17 mm) 0.6 in (14 mm) 0.9 in (23 mm) 1.5 in (37 mm) 1.7 in (44 mm)

Connection Diagram

e.g. isolating unit EN 2 Ex bn bu 1 4 + -

Wire color bn bu brown blue

Contact Assignment 1 4 3 2 + V DC - V DC free free 3

2 1

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

835

MM 18 Advanced
Magnetic Proximity Sensors Highlights

Sensing range up to 70 mm
DC

PNP output High switching frequency Short-circuit protection (pulsed)

Robust brass housing, nickel-plated with fine thread M18 x 1 mm Cable or connector Enclosure rating IP 67 LED status indicator

MM 18 Advanced

Dimensional Drawing dimensions in inches (mm)

Accessories Cables and connectors Mounting brackets Magnets

page 909 925, 926 978, 979

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

836

Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Selection Table Sensing range Sn in (mm)
2.8 (70) 2.8 (70)

10...30 V DC 10% of Ub 2 V with Ia max. 10 mA 300 mA 2 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Brass, nickel-plated, plastic 25 Nm PUR-PVC, 3 x 0.25 mm2

Magnetic alignment
Axial Axial

Switching output
PNP PNP

Output function

Switching frequency f in Hz
5000 5000

Connection type

Type

Part no.

Cable 2 m Connector M12 x 1 mm

MM18-70APS-ZU0 MM18-70APS-ZC0

7 900 272 7 900 274

Sensing Ranges Magnet type


M 1.0 M 2.0 M 3.0 M 4.0 M 5.0/5.1

Sensing Range sn Any installation type (flush or non-flush) in a non-magnetizable material


0.9 in (24 mm) 1.0 in (25 mm) 1.5 in (38 mm) 2.8 in (70 mm) 3.3 in (85 mm)

Sensing Range sn Flush installation in a magnetizable material (e.g. iron)


0.6 in (16 mm) 0.7 in (17 mm) 1.3 in (32 mm) 2.2 in (55 mm) 2.4 in (60 mm)

Connection Diagram

PNP

bn bk bu

1 4 3

+ DC -

Wire color bn bk bu brown black blue

Contact Assignment 1 4 3 2 + V DC NO - V DC free 3

2 1

4
837

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

MM 18 NAMUR
Magnetic Proximity Sensors Highlights

Sensing range up to 60 mm
DC

High switching frequency NAMUR to EN 50 227 Shielded or unshielded LED status indicator

Robust brass housing, nickel-plated with fine thread M12 x 1 mm Cable or connector Enclosure rating IP 67

MM 18 NAMUR

Dimensional Drawing dimensions in inches (mm)

Accessories Cables and connectors Mounting brackets Magnets Power supply

page 909 925, 926 978, 979 966

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

838

Electrical and Mechanical Data Operating voltage Ub Rated voltage Un Ripple Upp Power consumption, attenuated Power consumption, unattenuated Internal capacitance Internal inductance Cable resistance Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Short circuit protection (pulsed) Reverse polarity protection Enclosure rating to EN 60529 Shock and vibration stress Ambient temperature Ta Housing material Tightening torque Connection cable Max. data for connecting isolating unit EN 2 EX or other approved isolating amplifier: Short circuit current Ik max No load voltage Uo Power loss Pmax Selection Table Sensing range Sn* in (mm)
2.8 (70) 2.8 (70)

5...25 V DC 8.2 V DC 5% of Ub 2.5 mA 1.0 mA 15 nF 25 H 50 w 2 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...158F (-25...70C) Brass, nickel-plated, plastic 25 Nm PVC, 2 x 0.34 mm2

30 mA 16 V 75 mW

Magnetic alignment
Axial Axial

Version

Output function

Switching frequency f in Hz
5000 5000

Connection type

Type

Part no.

NAMUR NAMUR

Cable 2 m Connector M12 x 1 mm

MM18-70A-N-ZW0 MM18-70A-N-ZC0

7 900 288 7 900 289

* Sensing range sn based on installation in non-magnetizable material using magnet M 4.0. Sensing Ranges Magnet type
M 1.0 M 2.0 M 3.0 M 4.0 M 5.0/5.1

Sensing Range sn Any installation type (flush or non-flush) in a non-magnetizable material


0.9 in (24 mm) 1.0 in (25 mm) 1.5 in (38 mm) 2.8 in (70 mm) 3.3 in (85 mm)

Sensing Range sn Flush installation in a magnetizable material (e.g. iron)M


0.6 in (16 mm) 0.7 in (17 mm) 1.3 in (32 mm) 2.2 in (55 mm) 2.4 in (60 mm)

Connection Diagram

e.g. isolating unit EN 2 Ex bn bu 1 4 + -

Wire color bn bu brown blue

Contact Assignment 1 4 3 2 + V DC - V DC free free 3

2 1

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

839

MQ 10 Advanced
Magnetic Proximity Sensors Highlights

Sensing range up to 60 mm
DC

Cable or connector Enclosure rating IP 67 LED status indicator

PNP or NPN output High switching frequency Short-circuit protection (pulsed) Plastic housing

MQ 10 Advanced

Dimensional Drawing dimensions in inches (mm)

Accessories Cables and connectors Magnets

page 908 978, 979

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

840

Electrical and Mechanical Data Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia Time delay before availability tv Hysteresis H Repeatability R (Ub and Ta constant) Temperature drift EMC Wire-break protection Short circuit protection (pulsed) Reverse polarity protection Power-up pulse suppression Enclosure rating to DIN 40050 Shock and vibration stress Ambient temperature Ta Housing material Connection cable Selection Table Sensing range Sn in (mm)
2.4 (60) 2.4 (60) 2.4 (60) 2.4 (60)

10...30 V DC 10% of Ub 2 V with Ia max. 10 mA 300 mA 2 ms 1% - 10% of sr 1% of sr 10% of sr to EN 60 947-5-2 Yes Yes Yes Yes IP 67 30 g, 11 ms, 10 to 55 Hz, 1 mm -13...167F (-25...75C) Plastic PUR-PVC, 3 x 0.25 mm2

Magnetic alignment
Axial Axial Axial Axial

Switching output
PNP NPN PNP NPN

Output function

Switching frequency f in Hz
5000 5000 5000 5000

Connection type

Type

Part no.

Cable 2 m Cable 2 m Connector M8 x 1 mm Connector M8 x 1 mm

MQ10-60APS-KU0 MQ10-60ANS-KU0 MQ10-60APS-KT0 MQ10-60ANS-KT0

7 900 278 7 900 279 7 900 280 7 900 281

Sensing Ranges Magnet type


M 1.0 M 2.0 M 3.0 M 4.0 M 5.0/5.1

Sensing Range sn Any installation type (flush or non-flush) in a non-magnetizable material


0.9 in (23 mm) 0.9 in (24 mm) 1.4 in (36 mm) 2.4 in (60 mm) 2.7 in (68 mm)

Sensing Range sn Flush installation in a magnetizable material (e.g. iron)


0.5 in (12 mm) 0.4 in (10 mm) 0.6 in (15 mm) 0.8 in (20 mm) 1.0 in (25 mm)

Connection Diagram

PNP

bn bk bu

1 4 3

+ DC -

NPN

bn bk bu Wire color

1 4 3

+ DC Contact Assignment 4 1 3

bn bk bu

brown black blue

1 4 3

+ V DC NO - V DC
841

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com