You are on page 1of 2

STATE

PROJECT NUMBER

SHEET N0.

TOTAL SHEETS

GA.

D6010

446

13.71 POE 2+

P L

PI 1+44.45

140
ACWORTH DUE WEST ROAD
RGM

PLAN VIEW (WALL 1)


0 10 20 40

$REF32$

$REF31$

$REF30$

$REF29$

1060

TOP OF WALL EXISTING GRADE

1050

INTERLOCKED BLOCK
$REF24$ $REF23$ $REF22$ $REF21$

PROPOSED GRADE

1040
AREA = 193.00 sq. ft. BOTTOM OF WALL

AREA = 659.00 sq. ft.

$REF16$

$REF15$

$REF14$

$REF13$

1030 0+00

1+00

2+00
SCALE: 1" = 10 HORIZ 1" = 5 VERT

ELEVATION VIEW (WALL 1)

COBB COUNTY

DATE

REVISIONS

DATE

REVISIONS

PARSONS PARSONS {
NORCROSS, GA 30092
$REF08$ $REF07$ $REF06$ $REF05$

B
O

CO U

5390 TRIANGLE LANE, SUITESUITE 100 3577 PARKWAY PARKWAY, 100 NORCROSS, GA 30092

DESIGNER:
I A

RDS SSR RDS TGG

1 32 8

OF

O GE

CHECKER: DRAFTER: ENGINEER:

DEPARTMENT OF TRANSPORTATION
8/19/2009 H:\646753 Acworth Due West Rd\99 DESIGN\D6010WE03.dgn 9:28:24 AM

RGM

POB 0+00.00
WALL 1

2+00

1+00

P L

SCALE IN FEET

1060

1050

1040

1030

ACWORTH DUE WEST RD.


GRAVITY WALL 1 PLAN & ELEVATION
31-03

T
Y

ST
A

STATE

PROJECT NUMBER

SHEET N0.

TOTAL SHEETS

GA.

D6010

446

P L

EXISTING GROUND LINE 8" MIN. LOW PERMEABLE SOIL BACKFILL

0+00

1060
$REF32$ $REF31$ $REF30$ $REF29$

1050
EXISTING GRADE TOP OF WALL PROPOSED GRADE
$REF24$ $REF23$ $REF22$ $REF21$

1040

PROPOSED GRADE BOTTOM OF WALL

$REF16$

$REF15$

$REF14$

$REF13$

1030 0+00

I A

NORCROSS, GA 30092

1 32 8

OF

O GE

$REF08$

$REF07$

$REF06$

$REF05$

8/19/2009 h:\646753 acworth due west rd\99 design\D6010WE04.dgn 9:28:29 AM

RGM

POB 0+00.00

TOP OF WALL 2 Retained Soil 1 1 1 UNIT DRAINAGE FILL (3/4" CRUSHED ROCK OR STONE) REVERSED & INTERLOCKED KEYSTONE STANDARD UNITS (SEE DETAIL) COLLECTOR DRAIN (TYP.) COBB DOT STANDARD SIDEWALK (SEE SHT. 5-09 FOR DETAIL) 1H:8V BATTER PROPOSED FINISHED GRADE (SEE WALL ELEVATION) KEYSTONE STANDARD UNIT (TYP.) KEYSTONE STANDARD CAP UNIT (TYP.)

POE 1+36.91

PI 1+04.61

WALL 2
6" X 50.5" REINFORCED

1+00

CONCRETE OR 6" X 50.5" COMPACTED CRUSED STONE LEVELING PAD)

Foundation Soil

P L

P L
Typical Reversed & Interlocked Wall Section
SCALE: 1" = 4 BACKFILL

ACWORTH DUE WEST

WALL FACE

SCALE IN FEET

PLAN VIEW (WALL 2)


0 10 20 40

BACK CUT

1060
EXISTING GROUND LINE AREA = 358.00 sq. ft. 8" MIN. LOW PERMEABLE SOIL BACKFILL TOP OF WALL AREA = 440.50 sq. ft.

Reversed & Interlocked Detail


NOT TO SCALE

KEYSTONE STANDARD

1050
1 Retained Soil 1

CAP UNIT (TYP.) KEYSTONE STANDARD UNIT (TYP.) 1H:8V BATTER PROPOSED FINISHED GRADE (SEE WALL ELEVATION) COBB DOT STANDARD SIDEWALK (SEE SHT. 5-09 FOR DETAIL) COLLECTOR DRAIN (TYP.) 6" X 33.5" UNREINFORCED CONCRETE OR 6" X 33.5" COMPACTED CRUSED STONE LEVELING PAD)

UNIT DRAINAGE FILL (3/4" CRUSHED ROCK OR STONE) INTERLOCKED BLOCK

1040

Foundation Soil

1+00

1030 1+47

Typical Gravity Wall Section ELEVATION VIEW (WALL 2)


SCALE: 1" = 10 HORIZ 1" = 5 VERT SCALE: 1" = 4

COBB COUNTY

DATE

REVISIONS

DATE

REVISIONS

PARSONS PARSONS {

CO U

ACWORTH DUE WEST RD.


GRAVITY WALL 2 PLAN, ELEVATION, SECTIONS & DETAIL 31-04

T
Y

5390 TRIANGLE LANE, SUITESUITE 100 3577 PARKWAY PARKWAY, 100 NORCROSS, GA 30092

DESIGNER:
ST
A

RDS SSR RDS TGG

CHECKER: DRAFTER: ENGINEER:

DEPARTMENT OF TRANSPORTATION

You might also like