Flow Calculation

Model No.: Serial No.: Tag No.: Pipe Size: Process: 6 in SCH 40 ID = 6,065 Wall = 0,28 VAPOR SOBRECALENTADO V100 (6 in SCH 40) -05-H-R-XX-XX V11860-02.1-2 Customer: Customer PO: Processed By: Veris Ref.: Process Date: File Name: Fluid Name: Super Heated VR INGENIERIA

VeraCalc Version: VP190-REV 6.0.0

AUTOMATIZACI0N

04-06-2009 08:46:47

I. Flow Equation
Mass Flow Rate for Steam

II. Constants
Term Description Numeric Constant Flow Coefficient Pipe ID Atmos Pressure Value 162,8064753 0,7442 6,065 14,70 Units

N K D Pa

in psi

III. Flow Rate and Differential Pressure


Term Description Mass Flow Rate Flow Constant Flowing Pressure Flowing Temperature Flowing Density Expansion Factor Maximum 18000 3304,97 300 300 0,5423 0,9995 Nominal 15000 3305,45 300 300 0,5423 0,9997 Minimum 5000 3306,41 300 300 0,5423 1,0000
psi G

Units kg/hr

Qm C' Pf Tf
f

C lbm/ft^3

Yv

Fa
hw

Thermal Expansion Factor Differential Pressure

1,007 29,663

1,007 20,593

1,007 2,287 in H2O(68F)

IV. Structural Limits


Term Max Temp Max Press ANSI Eq
ANSI 600 ANSI 600

at User's Maximum
427 C at 300 PSI G 915 PSI G at 300 C

Ultimate Maximum
427 C at 825 PSI G 1440 PSI G at 38 C

Limiting Component at Ultimate


Mounting Assembly Instrument Head

Maximum Allowable Flow Rate at Maximum Column: Maximum Insert/Retract Flow Rate at Maximum Column:

34068,68 kg/hr (106,885 in H2O(68F))