SAMWOO power System CORPORATION is a pioneer and leader in recognizing the needs for air management products and air control devices for energy processing plants and power stations. The modern plants require high qual I ty dampers wi th vari ous appl I cati on and the cl ients demands are varying faster than ever.
SAMWOO power System CORPORATION is a pioneer and leader in recognizing the needs for air management products and air control devices for energy processing plants and power stations. The modern plants require high qual I ty dampers wi th vari ous appl I cati on and the cl ients demands are varying faster than ever.
SAMWOO power System CORPORATION is a pioneer and leader in recognizing the needs for air management products and air control devices for energy processing plants and power stations. The modern plants require high qual I ty dampers wi th vari ous appl I cati on and the cl ients demands are varying faster than ever.
SAMWOO POWER SYSTEM CORPORATION INDEX - A Damper for Power Plant 1. Single Louver Damper 2. Double Louver Damper 3. Tandem Louver Damper 4. Guillotine Damper 5. Flap Damper SAMWOO POWER SYSTEM CORPORATION INDEX - B Damper for Power Plant 6. Bypass - System 7. Special Damper Diverter Damper Blanking Plate (Guillotine Damper) Stack Damper SAMWOO POWER SYSTEM CORPORATION INDEX - C Damper and Duct Accessory for NPP 8. Nuclear Power Plant Manual Damper Control Damper Bubble Tight GRD Duct Accessory !. nlroduclon We, ever since the modest beginning in 1998, have been a pioneer and leader in recognizing the needs for air management products and air control devices for energy processing plants and power stations. We have engaged in the various kinds of construction project such as a Thermal Power Plant, Combined- Cycle Power Plant, Flue Gas Denitrification(DeNox) Plant, Flue Gas Desulphurisation(FGD) Plant, Cement Plant, Gas Turbine Plant, Steel Smelting Plant, Waste Heat Recovery Plant, Garbage Incinerating Plant, Chemical Process Plant, and other industrial plant with right machinery & equipment capabilities, superior manpower, and remarkable technical capability to design, manufacture and erect of the wide ranges of air/flue gas control or isolation dampers. The modern plants require high qual i ty dampers wi th vari ous appl i cati on and the cl i ents demands are varying faster than ever, so the wi der vari ety of comprehensive manufacturing & servicing are required. In order to successful l y meet those requirements, in everything we do, our management focus i s an providing clients with the very best quality products. Surely we have fabricated those best complete lines of dampers such as Single Louver Damper, Tandem Louver Damper, Fl ap Damper, Gui l l oti ne Damper, Diverter Damper and other special dampers resul ti ng from the workmanshi p of ski l l ed peopl e woven into the modern equipment & machinery Now thanks to our best quality products we have enjoyed a high reputation from the clients. Furthermore we are very eager to expand our activity & participation to abroad as offering our advanced technology, and to diversify our products to sell in different markets. Based on this conception of further branching out our performance we have taken part keenly in several overseas projects in Japan, China, Russia, India, Taiwan, Iran, UAE, Kuwait, Indonesia, etc. Parallel to our positive contribution, rooted in The Sincerity Spirit and The Creativity of Workmanship as the motto, we shall surely continue to dedicate ourselves to building excellence of entire Dampers to meet the variety of requirements and needs from customers. SAMWOO POWER SYSTEM CORPORATION - Thermal Power Plants - DeNox Plants - FGD Plants - Cement Plants - Chemical Plants - Other Energy Processing Plants - Thermal Power Plants - DeNox Plants - FGD Plants - Gas Turbine Plants - Cement Plants - Chemical Plants - Other Energy Processing Plants Si ngl e Louver Damper Tandem Louver Damper - Thermal Power Plants - DeNox Plants - FGD Plants - Gas Turbine Plants - Cement Plants - Chemical Plants - Steel Smeter Plant - Other Energy Processing Plants - Thermal Power Plants - DeNox Plants - FGD Plants - Gas Turbine Plants - Cement Plants - Chemical Plants - Other Energy Processing Plants Fl ap Damper Damper Fl ap Damper Damper 2. Producl Lne SAMWOO POWER SYSTEM CORPORATION - On-Shore Gas Turbine Plants - Off-Shore Gas Turbine Plants - Floating Oil Refinary Plants - HRSG Plant - Other Energy Processing Plants - Gas Turbine Plants - HRSG Plant - Other Energy Processing Plants - Steel Smeter Plants - Gas Turbine Plants - Garbage Incinerating Plants - Other Energy Processing Plants Di vert er Damper St ack Damper Speci al Damper 2. Producl Lne SAMWOO POWER SYSTEM CORPORATION We have developed proven sealing systems for various applications. Figures 1 ~ 6 depict the available sealing methods which can be applied to suit the respective requirements for sealing and operating conditions. Fi g. 1. Wi t hout Seal Feat ure This is a typical way to make blades swing through freely. For a modulation damper with no or very low sealing requirement. Fi g. 2. Fi xed Met al Seal Under dusty condition, this metal seal can be used. Blades seal just against fixed metal seal. This is for an abrasive and low sealing requirement. Fi g. 4. Adj ust abl e Met al Seal Blades seal against adjustable metal seal. For a very abrasive and sticky medum and average sealing requirement. Fi g. 3. Sl oped Fi xed Met al Seal Blades seal against sloped-fixed metal seal. For a gas with a high dust burden and low sealing requirement. Fi g. 5. Met al Leaf Seal (MLS) Seal Blades mounted lamellar stainless steel leaf seal for a high sealing requirement. Not suitable for high gas velocity, nor for mudulating purpose. Due to vibrations emanating from such conditions the lamellar seals might be destroyed. Fi g. 6. Met al Loop Seal (MLO) Seal This proven sealing method has been introduced in 1971 for handling of dust laden flue gases in powerstations and cement plants. The sealing elements consist of oblong, resilient, stainless steel loops. Even after long periods of deforrmation whilst a damper is closed the loops do to regain their original shape. Dust deposits and incrustrations simply break away due to seal flexing upon closing. For a very high sealing requirement. 4. Slandard Sealnq Syslem SAMWOO POWER SYSTEM CORPORATION Specially intended for shut-off dampers and diverters for combined cycle gasturbine plants, more generally for any large dimensioned flue gas isolation damper, we developed the new Nicroflex-Hiperform sealing system. This new sealing techique is a development based on the Nicroflex-MLO type of seal as shown in Fig. 6 on the left page. Geometrically shaped as a fully circular metal loop this sealing element affords a permanently high resilience of more than 30mm with enlarged loops even more. Heat distortion or certain misalignments can therefore be easily compensated. In relaxed condition such as damper opening the V-shaped backup plate positioned inside the circular loop provided additional lateral support. See picture1. It protects the seal against damage or destruction from high gas velocities and turbulence. In stressed condition such as damper closing, a wide area of contact is created between seal and mating surface providing an excellent sealing effect. See picture 2. The parts of the loops protruding sideways retain their curved shape and are thus able to withstand high pressure levels. The inernal V-shaped plate also acts as an end stop which limits the seal compression and prevents an unintentional over- deformation. Byplacing one or more additional metal loops inside the circular seal, its resilience can be adapted to suit specific service conditions. Even when deformed by point loads(tramp materials) the seal regains contact with the mating surface within a short distance. Dust deposits and incrustations of the metal loop simply break off due to seal flexing during damper closing. Due to the wide area of contact created between seal and mating surface a double sealing effect can be acheived with one sealing element only. See picture 3. The second plane of blades common in conventional Double Louver Dampers or advanced Tandem Louver Dampers, is unnecessary. This simplifies the whole damper design and reduces maintenance. Also this brings 100% gastight with sealing air system at an extremely competitive price. 5. New Sealnq Syslem SAMWOO POWER SYSTEM CORPORATION Normally each thermal power plant requires several dampers such as a guillotine damper, louver type damper, and tandem lover damper to isolate or control air/gas volume & path. Especially the flow gas of a coal-fired thermal plant has a lot of dust, therefore, all dampers located in gas path have to be equipped with particular feature of sealing as well as with less pressure lose shape. A Single Louver Damper which has single skin-multi blades is normally used for isolation or modulation purpose with leaf type seal system that leads about 99.9% tightness. This damper is required in where no 100% tightness is required. A tandem louver damper has two-layer of blades which may allow the induced sealing air from sealing air system to keep 100% tightness. This damper is used in either gas or air path. The sealing type for this damper is a leaf type sealing between blades and a loop type sealing between blade and frame. The chamber which is made when the blades being closed is very narrow, so it requires less air pressure and volume. A guillotine damper with lack-pinion part is performed very well in especially gas path where flows much dust away. It is designed for electric driven actuator especially and its blade operates very smoothly and confidently. This damper is used for isolation purpose as well as for man safety during maintenance period.t DAMPEPS lor Thermal Power Planls SAMWOO POWER SYSTEM CORPORATION DAMPEPS lor Thermal Power Planls SAMWOO POWER SYSTEM CORPORATION Dampers for DeNox plants are very critical equipment to roll in the successful operation of the plants. For controlling and regulating of flue gases the dampers shall be used under elevated temperature, heavy particulate load and pressure. The following dampers are normally required for the DeNOx systems: DeNOx Inlet Damper, DeNOx Outlet Damper, DeNOx Bypass Damper The DeNOx Inlet Damper is normally used to isolate the system, or to modulate flue gases to the system. The DeNOx Outlet damper also functions to regulate the flow of heated air as well as to isolate like Ihe Inlet Damper. The Bypass Damper is applied to allow the system flow to be directed to the DeNOx module. It can be used in connection with the Inlet Damper to control the flow during heat-up service. Generally the type of Inlet Damper is a Tandem Louver, Double Louver or Flap, and that of Outlet is a Single Louver, Tandem Louver or Double Louver. The Bypass Damper is normally a Tandem Louver, Double Louver, or Guillotine type. The Single Louver Damper can reach upto 99.9% gas tight. And other dampers with seal air system can be 100% tight. Both electric and pneumatic type actuator can be used for the dampers except for the Guillotine Damper. The electric actuator is to be recommended for the Guillotine Damper for better and stable function of the damper. We are capable of fabricating what the client demands and request. Especially our unique patented design minimizes any deformation or deflection caused by thermal expansion, or pressure load. Also patented sealing feature benefits extremely excellent sealing efficiency. Double louver damper, ND 6789 x 5390mm, for FGD plant. With seal air, 100% gastight in term of UVV regulations. Seals are of the NICROFLEX-HIPERFORM, DBP, type. DAMPEPS lor DeNox Planls SAMWOO POWER SYSTEM CORPORATION Louvor damper, ND 9000 x 10000mm, for the gastight isolation of a DeNOx catalytic reactor. The new, patented, lattice supported single shell damper blades, DBP, minimise the pressure drop across the open damper and no distortion occurs when exposed to high temperatures. DAMPEPS lor DeNox Planls SAMWOO POWER SYSTEM CORPORATION FGD plants remove poisonous or harmful gas components such as SO2 discharged from a coal or oil fired boiler system. Normally this gas component makes the damper material corroded easily when the gas being condensed or below dew point. So the Dampers for FGD plants are very critical equipment to protect the system or the absorber. The following dampers are normally required for the FGD systems: Booster Fan Inlet Damper, FGD Inlet Damper (Booster Fan Outlet Damper), FGD Outlet Damper, FGD Bypass Damper The Booster Inlet Damper is used for isolation application. Typically it is a Single Louver Damper with carbon steel fabrication. The FGD Inlet Damper with normal carbon steel fabrication is used to isolate flue gases to the system. Typically it is a Single Louver Damper or Tandem Louver Damper. The FGD Outlet damper is placed behind the absorber, and functions to isolate the bypass flow as well as to protect the absorber at emergency situation. Due to wet or moisture condition, the material for this damper is high alloy; nickel-chrome based stainless steel. The Bypass Damper is applied to allow the system flow to be directed to the stack. It can be used in connection with the Inlet/Outlet Damper to control the flow at emergency. Generally FGD Outlet Damper is a Tandem Louver, Double Louver or Flap Damper. The Bypass Damper is normally a Tandem Louver, Double Louver or Diverter Damper. Single Louver Damper can reach upto 99.9% gas tight. And other dampers with seal air system can be 100% tight. Both electric and pneumatic type actuator can be used for the dampers. We are capable of fabricating what the client demands and request. Especially our unique-patented design minimizes any deformation or deflection caused by thermal expansion, or pressure load. Also patented sealing feature benefits extremely excellent sealing efficiency. Tandem-damper DN 5000 x 5000mm Man safe with seal air(100% tighteness) DAMPEPS lor FGD Planls SAMWOO POWER SYSTEM CORPORATION lever flap damper for FGD inlet DN 2500 x 2500mm, man safe with seal air (100% tightness) Tandem Louver damper with seal air system (100% gastight) for FGD inlet DN 5200 x 5200mm, Seal type is NICROFLEX-MLO Single Louver damper for Booster fan inlet DN 4500 x 6500mm, Gas Tightness is 99.9% Leaf seal MLS DAMPEPS lor FGD Planls SAMWOO POWER SYSTEM CORPORATION Di vert er, ND 2700 x 2700mm, for off-shore gasturvine plant in Denmark, powered by a hydraulic actuator with fail safe function St ack cap for gast urbi ne pl ant , ND 5400 x 5400mm. The damper provides automatic pressure relief and opens without external energy when a pre-adjustable pressure level is reached In combined cycle gasturbine power plants the turbine exhaust gas is directed either to a waste heat recovery boiler or to the waste gas stack by means of single blade diverter dampers. In case of smaller diverters, this blade is pivoted directly by means of a peripherally positioned drive shaft and straight levers, while lager units are actuated by a central shaft and internal toggle lever drive system. Diverters can be insulated internally or externally. To avoid heat radiation into the closed off plant section, the blade itself should be also insulated. Patented features, our special designed diverter is capable of performing very well especially under high temperature and velocity. The diverter with patented sealing design and blade structure can be heated up evenly to prevent any malfunction caused by any thermal expansion or deformation when the plant is running, with high performance and stability to suit every plant layout or new construction. And a 100% gas tight shut off is achieved in both positions with sealing air system. We also supply the following equipment: diffusers, transitions, diverters, expansion joints, blanking plates and guillotines, duct extensions, exhaust stacks and silencers (simple and combined cycle), louver dampers, guillotines, and stack dampers. DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls SAMWOO POWER SYSTEM CORPORATION Diverter, DBP, ND 2400 x 6400mm, during final assembly and testing in the works of work shap. This Diverter is in service behind a LM 6000 General Electric gasturbine. The casing is intermally insulated and the damper is operated by an electric actuator. Seal air and double seals of the NICROFLEX-MLO type proviide a 100% shut-off in both end positions. The patented, lattice structure reinfored blade remains free of distortions when exposed to high, as well as rapidly fluctuating, gas temperatures. Di vert er, ND 2400mm di a., for off-shore gasturbine plants in Norway. This Diverter, as well as the one depicted overleaf, was equipped with the NICPROFLEX-HOPERFORM sealing system DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls SAMWOO POWER SYSTEM CORPORATION We have developed a complete bypass sytem for gas turbine plants. Basis of the system is the proven diverter with its patented lattice structure reinforced damper blade as well as the patented highly resilient Nicroflax-Hiperform sealing system measure approx.30m. all parts are provided with internal insulation. The dimensions of all system components can be adapted to suit different gas turbine frame sizes. The diverter itself may be electrically or hydraulically operated During turbine start up the diverter may be utilized for volume control operations toward the boiler. With double seal and seal air injection a 100% gastight. Man safe isolation is achieved. It requested, an additional blanking plate guillotine can be supplied. DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls SAMWOO POWER SYSTEM CORPORATION We have developed the new NICROFLEX- HIPERFORM sealing system for shut-off and modulating dampers, more specifically however, for combined cycle gas turbine diverters, The tubular sealing elements (fig. 1, 2, and 3) are made of a certain stainless steel and thus feature a very high resilience. In their standard configuration they accept deformation of up to 30mm. Point loads caused by tramp material are also rapidly absorbed and contact with the landing bar is regained within short distances. The internal, V-shaped back up bar, stabilizes the sealing element in uncompressed condition and ensures that it can withstand vibrations caused by high gas velocities or turbulence, while operating in modulation mode. With a single sealing arrangement (single sealing plane) an area equivalent tightness of 99.98% is achieved. Damper with two sealing planes and seal air injection provide a 100% gastight, man safe shut- off illustration 3 depicts a new, also patented seal arrangement by means of which a 100% gastight shut-off can be achieved with only one sealing element. In compressed conditions, e,g, damper closed, the seal fattens and bulges outward, thereby creating a broad area of contact able to accommodate two sealing surfaces, Gas leakage is prevented as usual by seal air injection. The photos depict a diverter damper with internal insulation, the blade featuring the patented lattice type support structure with insulation and double seal. DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls SAMWOO POWER SYSTEM CORPORATION Large diverters are usually designed with an international toggle lever drive mechanism. Of advantage is that the actuation forces act in the blade center and are hence evenly distributed throughout the blade structure. Also, in the end positions, when the blade is subject to maximum pressure Differential and its seals are making contact with the landing bars, the toggle lever system provides for an effective conversion of torque into very high closing force. Smaller diverters, however, can be operated through a direct driven, pivoting shaft. The balde may be equipped with either single or double sided thermal Insulation in order to reduce heat transmission into the closed off section. The blade can be electrically or hydraulically powered. During plant start up volume control and gas flow modulation is possible. The kinematics of the toggle lever system in fact improves the modulation characteristics of the blade. Diverter blade with Lattice structure Reinforcement Toggle lever system With central drive shaft Hydraulic or Electric actuator Landing bar for Seal air charged Sealing system Seal air fan (with stand by) Casing with internal or External insulation 3 Diverter for the kayseri Power Station in Turkey Diverter ND 6000 x 2000mm, supplied to combined cycle power station Degussa at Antwerp DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls SAMWOO POWER SYSTEM CORPORATION We have developed and patented a new diverter blade design for gas turbine combined cycle plant service.
Generally, however, the design is eminently suitable for all high temperature service conditions. It has already proved Itself in several different application. By means of computer simulation the behavior of the blade under particular service conditions is exactly predictable in advance.
Together with also the new Nicroflex- Hiperform sealing system, notable for its great resilience and stability when subjected to high gas velocities, this design is an advantageous solution for even the largest damper dimensions. Please refer to our sealing features in this catalog. The schematic illustration depicts the lattice support structure of a high temperature diverter blade. The blades cover plates are floatingly and partially attached upon the structure. This prevents their distortion when exposed to uneven heating up. High temperature gas can flow freely through the lattice support structure. All its members heat up evenly and maintain a uniform temperature profile despite the fact that changes of gas temperature can occur very rapidly. Any deformation of the blades is thus positively avoided. Bearing Support of the main drive shaft
The main drive shaft is supported by maintenance free spherical sleeve bearings fitted into dust tight housings. Neither the exhaust gas nor the environment can ham those bearings. The large, specially coated spherical bearing surface ensure a smooth movement of the bearing irrespective of vibrations. The passages of the shaft through the diverter casing are sealed by packing glands with internal support ring. DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls SAMWOO POWER SYSTEM CORPORATION In combined cycle gasturbine power plants the turbine exhaust gas is directed either to a waste heat recovery boiler or to the waste gas stack by means of single blade diverter dampers. In case of smaller diverters, this blade is pivoted directly by means of a peripherally positioned drive shaft and straight levers, while lager units are actuated by a central shaft and internal toggle lever drive system. Diverters can be insulated internally or externally. To avoid heat radiation into the closed off plant section, the blade itself should be also insulated. Patented features, our special designed diverter is capable of performing very well especially under high temperature and velocity. The diverter with patented sealing design and blade structure can be heated up evenly to prevent any malfunction caused by any thermal expansion or deformation when the plant is running, with high performance and stability to suit every plant layout or new construction. And a 100% gas tight shut off is achieved in both positions with sealing air system. We also supply the following equipment: diffusers, transitions, diverters, expansion joints, blanking plates and guillotines, duct extensions, exhaust stacks and silencers (simple and combined cycle), louver dampers, guillotines, and stack dampers. Gui l l ot i ne damper wi t h doubl e c abl e dr i ve. This design was developed in order to meet the requirements of very high temperature service combined with extreme gas dust burdens. The main drive shaft moves both cables synchronuousoy in voth directions thereby ensuring a smooth operation of the damper blade under extreme conditions. First developed in 1971, nearly 1000 units of its type have been successfully put into service all over the world and it has since become a classic. DAMPEPS lor Cemenl Planls SAMWOO POWER SYSTEM CORPORATION Gui l l ot i ne damper, VD 2200mm di a., to fit a circular waste gas duct of a cement kiln, equipped with NICROFLEX-MLO seals. Design temperature: 350 degrees C. Powered by rack and pinion system and electric Actuator. Gui l l ot i ne dampers during final assembly and testing at Rauenstein works. A total of six units were supplied, two each with the dimensions 3200 x 4600mm, 4200 x 3200mm and 4000 x 4200mm, under cover of one order, to the cement plant Hoping in Taiwan, one of the largest limestone milling plants in the world. Design temperature: 400 degrees C Design pressure: 100 mbar Dust burden: 1100 g/acbm DAMPEPS lor Cemenl Planls SAMWOO POWER SYSTEM CORPORATION W are fully able to supply our dampers to where other special dampers to be requried such as steel smeter plants, cement plants, chemical processing plants, waste heat recovery plants as well as power plants. Goggle Valves provide a 100% gastight isolation of gas mains in terms of UVV regulations, without any sealing media. The gastight shut-off is maintained even upon loss of external engergy and corresponds to that of a blind flange connection. This damper is used for the shut-off of blast furnace or coke gas mains. Sickle isolators are used for handing blastf- urnace exhaust or ther dust laden gases. Dust sealing is hermetic and corresponds to that of a blind flange connection in terms of UVV regulations. A blind disc pivots around a fixed point positioned outside the duct. A coaxially moveavle sealing frame is first retracted, thereby creating a slot through whichthe disc travels. The sealing frame is either actuated hydraulically or electrically. Once locked, the seal between disc and frame remains intact, even upon loss of all extermal energy. Toggle disc valves are used for the shut-off gas mains. They are considered technica- lly tight sealing valves. (to DIN 3230) The high sealing efficiency is achieved by means of an endless sealing element upon which the valve disc is pressed down by the action of the main levers when the valve closes. On opening the valve, the disc moves initially away from the seal in a cozxial direction and is suvsequently turned about by meanner, no wear takes place at the seal. Toggle disc valves can be powered by any type of actuator. In combination with counterweights or sprin- gs they may serve as emergency valves. Toggl e di sc val ve, ND 3000mm di a., DVGW approved, valve in fully open position. The valve is equipped with a double seal landing bar, thereby providing a cavity into which Nitrogen is injected when the valve is closed. The Nitrogen pressure is used to monitor the valve tightness continuously. The sealing element itself is fitted tothe valve disc and is easily replaceable. Isol at i on and gas modul at i on syst em, DBP, ND 600 x17500mm, for a gasturbine combined sycle power plant. This damper is used dither, to isolate the integrated bypass of the waste heat recovery boiler completely, 17500mm is facilitated by application of the new, patented, lattice supported single shell blade design. The blades are made up of 17500mm long latticed girders upon which floating diaphragm cover plates are fitted. DAMPEPS lor Clher Planls SAMWOO POWER SYSTEM CORPORATION Goggl e i sol at or, ND 3000mm di a., DVGW approved, with gastight castight casing, serving as main isolator in terms of UVV regulations, in the gas supply duct of a blastfurnace gas fired boiler. The sealing frame, as well as goggle and blind disc, are electrically actuated. Si ckl e i sol at or, ND 2200mm di a., for cement factory, with electric actuator. Louver damper, ND 6400 x 6400mm, i n st ai nl ess st eel const ruct i on. Each blade is driven separately by means of a fail safe actuator and opens without any external energy. Opening time is adjustable between 0,5 and 10 sec. DAMPEPS lor Clher Planls SAMWOO POWER SYSTEM CORPORATION DESCRIPTION Design points for Manual Damper are as follow. Seismic : SSE 4.5g RIM Safety : Seismic Cagory Design Non Safety : Seismic Cagory Design Environmental : 1 x 10^4 Gy Safety Related 1E Equipment related Safety Related non-metal related In accordance with IEEE 323, 344, 382
Leakage Class Frame Leak Class B~C Seat Leak Class ~ In accordance with ASME AG-1-97, DA-5730 Butterfly Type : Frame - C, Seat - ~ Opposed Type : Frame - C, Seat - Check Damper : Frame - C, Seat - Back Draft Type: Frame - C, Seat - Perfact Technical Data Lead Time : 10 weeks after receipt of P/O
We, SWPS, already have supplying record to Korean YGN #5/6, UCN #5/6 after Equipment Qualification. Material * Frame & Flange : Carbon Steel ASTM A36 or KSD3503 / JIS3101 * Blade : Galvanized Steel ASTM A653 or KSD3506 * Shaft : Carbon steel or Stainless Steel ASTM A36 or A276 / KSD3503 or 3706 * Blade & Shaft Seal : Gasket EPDM or Neoprene * Linkage & Link Arm : Carbon Steel ASTM A36 or KSD3503 / JIS3101 * Bearing : Pillow Block Flang Mounted Back Draft - Ball Bearing or Bushing All Damper - Oil Impregnated Type Coating & Painting Painting or Hot Dipping Gavanizing Fucntion - Manual Damper Butterfly Type : Modulation & Isolation Opposed Type : Only Modulation Type Check Damper : Only Isolation Type Back Draft Type:Only Isolation Type Prototype Test Qualification Pressure Drop : * All Dampers : MAX0.1"WG(2.54mmAq) * Down Flow CKD : Opening Pressure - 1.7"WG(43mmAq) Operating Load - 0.4"WG(10mmAq) * Up Flow CKD : Operating Load - 0.7"WG(18mmAq) * Back Draft Damper Operating Load - 0.27"WG(7 mmAq)
Flow Characteristics Test Qualification * AMCA500 Standard 5.1, 5.2, 5.3, 5.4, 5.5 Only Modulation Damper Test Cycle Repetition Test Qualification * Isolation Type : Full Strock 2,100 Time * Modulation Type : Full Strock 2,100, 20% Partial Strock 29,000 Time Test Butterfly Damper Round Butterfly Damper Round Check Damper Check Damper Round Butterfly Damper (Gear Type) Back Draft Damper Check Damper (Multy Section) Round Check Damper (Down Flow System) Oppose Blade Damper (Gear Type) Manual Dampers lor Nuclear Power Planls SAMWOO POWER SYSTEM CORPORATION DESCRIPTION The belows are Control Dampers' design items. Seismic : SSE 4.5g RIM Safety, Seismic Cagory N-safety Seismic Cagory Environmetal : 1 x 10^4 Gy Safety Related , 1E Equipment applied Safety Related , non metalic applied In accordance with IEEE 323, 344, 382
Leakage Class Frame Leak Class B~C applied Seat Leak Class ~ Based on ASME AG-1-97, DA-5730 Butterfy Type : Frame - C, Seat - ~ Opposed Type : Frame - C, Seat - - Parallel Damper : Frame - C, Seat - Any Special orders are available as per your request. Perfect Technical Data We, SWPS has already supplying record to Korean YGN #5/6, UCN #5/6 after Wyle Lap. .(US)'s Equipment Qualifcation. Material * Frame & Flange : Carbon Steel ASTM A36 or KSD3503 / JIS3101 * Blade : Galvanized Steel ASTM A653 or KSD3506 * Shaft : Carbon steel or Stainless Steel ASTM A36 or A276 / KSD3503 or 3706 * Blade & Shaft Seal : Gasket EPDM or Neoprene * Linkage & Link Arm : Carbon Steel ASTM A36 or KSD3503 / JIS3101 * Bearing : Pillow Block Flang Mounted All Damper - Oil Impregnated Type
Coating & Painting Painting or Hot Dipping Gavanizing Fucntion - Control Damper Butterfy Type : Modulation & Isolation Opposed Type : Only Modulation Type Parallel Damper : Only Isolation Type Prototype Test Qualifcation Pressure Drop : * All Dampers : MAX0.1"WG(2.54mmAq)
Flow Characteristics Test Qualifcation * AMCA500 Standard 5.1, 5.2, 5.3, 5.4, 5.5 Only Modulation Damper Test Cycle Repetition Test Qualifcation * Isolation Type : Full Strock 2,100 Time * Modulation Type : Full Strock 2,100, 20% Partial Strock 29,000 Time Test PSR (Pneumatic Spring Return) Actuators Manufacure : Automax (USA) Operation : pinion Gear Type Pressure : 75~105 PSIG (5.3~8.4 kg/cm) Solenoid Valve : 3Way Type ASCO GC Positioners : 4~20mA - 3~15 PSIG Signal Modulation Dampers Mounted ESR (Electro Hydraulic Spring Return) Actuator Manufacture : ASCO GC or PMT (USA) Operation : Cylinder Type Voltage : 120VAC 1.5A Limit S/W : DPDT Type 125VDC Manufacture : Namco, Yongsung Electric, Butterfly Control Damper wth ESR Actuator Parallel Blade Control Damper wth PSR Actuator ESR (Electro hydrauric Spring Return) Actuator PSR (Pneumatic Spring Return) Actuator DPDT Type Limit Switch 3 Way Type Solenoid Valve with Spring Return Oposed Blade Control Damper with PSR Actuator Parallel Balade Control Damper - Supplied Quinsan NPP in China Conlrol Dampers lor Nuclear Power Planls SAMWOO POWER SYSTEM CORPORATION DESCRIPTION The general design items of control dampers for safety and non safety are as follow.
Seismic : SSE 4.5g RIM Safety, Seismic Cagory N-Safety Seismic Cagory Environmental : 1 x 10^4 Gy Safety Related 1E Equipment Safety Related non metalic applied In accordancw with IEEE 323, 344, 382
Leakage Class Frame Leak Class A~B Seat Leak Class 0~ ASME AG-1-97, DA-5730 Buble Tight : Frame - A, Seat - 0 Class : Frame - B, Seat - 1 CFM / ft Any Special orders are available as per your request. Perfect Technical Data Bubble Tqhl Conlrol Dampers lor Nuclear Power Planls Material * Frame : Carbon Steel ASTM A36 or KSD3503 / JIS3101 * Blade : Carbo Steel & Galvanized Steel ASTM A36 or KSD3503 / JIS3101 ASTM A653 or KSD3506 * Shaft : Carbon steel or Stainless Steel ASTM A36 or A276 / KSD3503 or 3706 * Blade & Shaft Seal : Gasket EPDM or Neoprene * Linkage & Link Arm : Carbon Steel ASTM A36 or KSD3503 / JIS3101 * Bearing : Pillow Block Flang Mounted Ball Bearing Type
Coating & Painting Painting or Hot Dipping Gavanizing Fucntion - Control Damper Buble Tighr Type : Only Isolation Type Prototype Test Qualification Pressure Drop : * All Dampers : MAX0.1"WG(2.54mmAq) Cycle Repetition Test Qualification * Isolation Type : Full Strock 2,100 Time PSR (Pneumatic Spring Return) Actuators Manufacure : Automax (USA) Operation : pinion Gear Type Pressure : 75~105 PSIG (5.3~8.4 kg/cm) Solenoid Valve : 3Way Type ASCO GC ESR (Electro Hydraulic Spring Return) Actuator Manufacture : ASCO GC or PMT (USA) Operation : Cylinder Type Voltage : 120VAC 1.5A Limit S/W : DPDT Type 125VDC Manufacture : Namco, Yongsung Electric, SA M WO O PO WER SYSTEM C O RPO RA TIO N DPDT Type Limit Switch 3 Way Type Solenoid Valve with Spring Return ESR (Electro hydrauric Spring Return) Actuator Dual Disk Type Bubble Tight Control Damper wth PSR Actuator PSR (Pneumatic Spring Return) Actuator Round Dual Disk Type Bubble Tight Control Damper wth PSR Actuator Round Dual Disk Type Bubble Tight Control Damper wth ESR Actuator Dual Disk Type Bubble Tight Control Damper wth ESR Actuator DESCRIPTION The general design items are as follow. Seismic : SSE 4.5g RIM Safety, Seismic Cagory N-safety Seismic Cagory Environmental : 1 x 10^4 Gy Safety Related 1E Equipment applied Safety Related non metalic applied In accordancw with IEEE 323, 344, 382 Fucntion - GRD * 1 Type : Supply Grille 3/4" Blade Spacing Double deflection * 2 Type : Supply Register 3/4" Blade Spacing Double deflection with Opposed Blade Dampers * 3 Type : Return / Exhaust Grille 35~ 45 Fixed Blade * 4 Type : Return / Exhaust Grille 35~ 45 Fixed Blade with Opposed Blade Dampers * 5 Type : Ceiling Diffuser with Opposed Blade Dampers 5B Type - 2 Way Flow System 5C Type - 3 Way Flow System 5D Type - 4 Way Flow System with Air-Intake Adaptor
Material * Frame & Blade : Carbon Steel (Q Class) ASTM A36 or KSD3503 / JIS3101 Galvanized Steeel ASTM A653 or KSD3506 Stainless Steel ASTM A240 or KSD3706 / JIS4304 Aluminum (T,R,S Class) ASTM B221 or KSD6759 (6063T5) * Flange Seal : Gasket Neoprene * Opposed Blade Damper : Carbon Steel ASTM A36 or KSD3503 / JIS3101 Galvanized Steeel ASTM A653 or KSD3506 Stainless Steel ASTM A240 or KSD3706 / JIS4304 Aluminum (T,R,S Class) ASTM B221 or KSD6759 (6063T5) Coating & Painting Painting & Galvanized Steel Test of Sound Measurement Perfect Technical Data Lead Time : 8 weeks after receipt of P/O We, SWPS has already supplying record to Korean YGN #5/6, UCN #5/6 afte Wyle Lap.(US)'s Equipment Qualification. Prototype Test Qualification
CODE & Standard : ADC-1062, GRD-84 ISO 5219 - Air distribution and air diffuser Test of Pressure Requirement Test of Area Velocity Factors Test of Throw, Terminal Velocity and Air Stream Drop Throw-Trmanal Velocity and Drop Mounting * 1 Type : Supply Grille Wall Mount, Ceiling Mounting * 2 Type : Supply Register Wall Mount, Ceiling Mounting * 3 Type : Return / Exhaust Grille Wall Mount * 4 Type : Return / Exhaust Grille Wall Mount * 5 Type : Ceiling Diffuser Ceiling Mounting Supply and Exhaust Grille Supply Exhaust Register Return and Exhaust Grille Return and Exhaust Register 2 Way Ceiling Diffuser 3 Way Ceiling Diffuser 4 Way Ceiling Diffuser Transfer Grille Adaptor for Ceiling Diffusers GPD lor Nuclear Power Planls SAMWOO POWER SYSTEM CORPORATION LOUVER DESCRIPTION SWPS Louvers are approved by AMCA 500 Standard. SWPS Louvers Type * A Type : Fixed Louvers * B Type : Operating Louvers * C Type : Operating Dual Combination Louvers * D Type : Back Draft Dual Combination Louvers (Intake) * E Type : Back Draft Dual Combination Louvers (Exhaust) * F Type : Emergency Opening Louvers Material * Frame & Blade : Aluminum ASTM B221 or KSD6759 (6063T5) * Screen Frame : Aluminum ASTM B221 or KSD6759 (6063T5) * Linkage : Aluminum or Steel Plate ASTM B221 or KSD3503 (SS400) * Coating Work : Painted Kynar 500 * Screen : Stainless Steel Mesh 1.6x 1/2" AMCA 500-94 Standard Test ...... * Free Area Design Certify ...... * Pressure Drop Test ...... * Air Leakage Test ...... * Water Penetration Test ...... * Operating Tes SWPS "F" Type Louvers * Opening at 0.2" WG Pressure for Spring Force * Pressure Drop : Same Class to SKAT Louvers * Material : Same Class to SKAT Louvers * General : Operating Louvers (Full Close or Full Open - 2 position) * Emergency : Full Open Mode * Closing : Stainless Steel Spring Force SILENCER DESCRIPTION * Designed IEEE & ASTM Standard * Material Frame : Galvanized Steel ASTM A653 or KSD3506 Caron Steel ASTM A36 or KSD3503 / JIS3101 Split : Galvanized Steel ASTM A653 or KSD3506 Caron Steel ASTM A36 or KSD3503 / JIS3101 Insulatin : Glass Cloth with Glass Wool or Glass Fiber * Remark : Combusting Rating for the Silencer acoustic fill and sealant is in accordace with ASTM E84 and NFPA255, or the equivalent * Selection Calculation of attenuator noise (PWL) Sound loss calculation Sum of the returning noise Decide in-door NC level Noise-Loss-NC level Application Louvers for Nuclear Power Plant Silencers for Nuclear Power Plant SWPS PENTHOUSE Where the free area is short, Penthouse offers broad free area from 4 way. SWPS SOUND LOUVERS Sound louvers attenuate the noise from machine room etc. to outside of it. Sound Louvers let the air flow free but attenuate the noise. This sound louvers are for multi purpose like the above. Ducl Accessares lor Nuclear Power Planls SAMWOO POWER SYSTEM CORPORATION SAMWOO POWER SYSTEM CORPORATION HEAD OFFICE #609 Center Plaza, Songdo-Dong, Yeonsu-Gu Incheon, Korea, (Zip Code : 406-840) Tel : +82-70-7603-3500 (rep.) / Fax : +82-32-858-2536 FACTORY - Namdong : #653-6 Kojan-Dong, Namdong-Gu Incheon, Korea, / Tel : +82-70-7603-3506 - Western : #612-1 Deagok-Dong, Seo-Gu Incheon, Korea, / Tel : +82-70-7603-3507 Site : www.swps.kr Mail : swps@swps.kr