You are on page 1of 31

DAMPER FOR POWER PLANT

SAMWOO POWER SYSTEM CORPORATION


SAMWOO POWER SYSTEM CORPORATION
INDEX - A
Damper for Power Plant
1. Single Louver Damper
2. Double Louver Damper
3. Tandem Louver Damper
4. Guillotine Damper
5. Flap Damper
SAMWOO POWER SYSTEM CORPORATION
INDEX - B
Damper for Power Plant
6. Bypass - System
7. Special Damper
Diverter Damper
Blanking Plate (Guillotine Damper)
Stack Damper
SAMWOO POWER SYSTEM CORPORATION
INDEX - C
Damper and Duct Accessory for NPP
8. Nuclear Power Plant
Manual Damper
Control Damper
Bubble Tight
GRD
Duct Accessory
!. nlroduclon
We, ever since the modest beginning
in 1998, have been a pioneer and
leader in recognizing the needs for
air management products and air
control devices for energy processing
plants and power stations.
We have engaged in the various
kinds of construction project such as
a Thermal Power Plant, Combined-
Cycle Power Plant, Flue Gas
Denitrification(DeNox) Plant, Flue
Gas Desulphurisation(FGD) Plant,
Cement Plant, Gas Turbine Plant,
Steel Smelting Plant, Waste Heat
Recovery Plant, Garbage
Incinerating Plant, Chemical Process
Plant, and other industrial plant with
right machinery & equipment
capabilities, superior manpower, and
remarkable technical capability to
design, manufacture and erect of the
wide ranges of air/flue gas control or
isolation dampers.
The modern plants require high
qual i ty dampers wi th vari ous
appl i cati on and the cl i ents
demands are varying faster than
ever, so the wi der vari ety of
comprehensive manufacturing &
servicing are required. In order to
successful l y meet those
requirements, in everything we do,
our management focus i s an
providing clients with the very best
quality products.
Surely we have fabricated those
best complete lines of dampers
such as Single Louver Damper,
Tandem Louver Damper, Fl ap
Damper, Gui l l oti ne Damper,
Diverter Damper and other special
dampers resul ti ng from the
workmanshi p of ski l l ed peopl e
woven into the modern equipment
& machinery
Now thanks to our best quality
products we have enjoyed a high
reputation from the clients.
Furthermore we are very eager to
expand our activity & participation to
abroad as offering our advanced
technology, and to diversify our
products to sell in different markets.
Based on this conception of further
branching out our performance we
have taken part keenly in several
overseas projects in Japan, China,
Russia, India, Taiwan, Iran, UAE,
Kuwait, Indonesia, etc.
Parallel to our positive contribution,
rooted in The Sincerity Spirit and
The Creativity of Workmanship as
the motto, we shall surely continue to
dedicate ourselves to building
excellence of entire Dampers to meet
the variety of requirements and
needs from customers.
SAMWOO POWER SYSTEM CORPORATION
- Thermal Power Plants
- DeNox Plants
- FGD Plants
- Cement Plants
- Chemical Plants
- Other Energy Processing Plants
- Thermal Power Plants
- DeNox Plants
- FGD Plants
- Gas Turbine Plants
- Cement Plants
- Chemical Plants
- Other Energy Processing Plants
Si ngl e Louver Damper
Tandem Louver Damper
- Thermal Power Plants
- DeNox Plants
- FGD Plants
- Gas Turbine Plants
- Cement Plants
- Chemical Plants
- Steel Smeter Plant
- Other Energy Processing Plants
- Thermal Power Plants
- DeNox Plants
- FGD Plants
- Gas Turbine Plants
- Cement Plants
- Chemical Plants
- Other Energy Processing Plants
Fl ap Damper Damper
Fl ap Damper Damper
2. Producl Lne
SAMWOO POWER SYSTEM CORPORATION
- On-Shore Gas Turbine Plants
- Off-Shore Gas Turbine Plants
- Floating Oil Refinary Plants
- HRSG Plant
- Other Energy Processing Plants
- Gas Turbine Plants
- HRSG Plant
- Other Energy Processing Plants
- Steel Smeter Plants
- Gas Turbine Plants
- Garbage Incinerating Plants
- Other Energy Processing Plants
Di vert er Damper
St ack Damper
Speci al Damper
2. Producl Lne
SAMWOO POWER SYSTEM CORPORATION
We have developed proven sealing systems for various applications.
Figures 1 ~ 6 depict the available sealing methods which can be
applied to suit the respective requirements for sealing and operating
conditions.
Fi g. 1. Wi t hout Seal Feat ure
This is a typical way to make blades swing through freely. For a
modulation damper with no or very low sealing requirement.
Fi g. 2. Fi xed Met al Seal
Under dusty condition, this metal seal can be used. Blades seal just
against fixed metal seal. This is for an abrasive and low sealing
requirement.
Fi g. 4. Adj ust abl e Met al Seal
Blades seal against adjustable metal seal. For a very abrasive and
sticky medum and average sealing requirement.
Fi g. 3. Sl oped Fi xed Met al Seal
Blades seal against sloped-fixed metal seal. For a gas with a high
dust burden and low sealing requirement.
Fi g. 5. Met al Leaf Seal (MLS) Seal
Blades mounted lamellar stainless steel leaf seal for a high sealing
requirement. Not suitable for high gas velocity, nor for mudulating
purpose.
Due to vibrations emanating from such conditions the lamellar seals
might be destroyed.
Fi g. 6. Met al Loop Seal (MLO) Seal
This proven sealing method has been introduced in 1971 for handling
of dust laden flue gases in powerstations and cement plants.
The sealing elements consist of oblong, resilient, stainless steel
loops. Even after long periods of deforrmation whilst a damper is
closed the loops do to regain their original shape. Dust deposits and
incrustrations simply break away due to seal flexing upon closing.
For a very high sealing requirement.
4. Slandard Sealnq Syslem
SAMWOO POWER SYSTEM CORPORATION
Specially intended for shut-off dampers and diverters for
combined cycle gasturbine plants, more generally for any large
dimensioned flue gas isolation damper, we developed the new
Nicroflex-Hiperform sealing system.
This new sealing techique is a development based on the
Nicroflex-MLO type of seal as shown in Fig. 6 on the left page.
Geometrically shaped as a fully circular metal loop this sealing
element affords a permanently high resilience of more than
30mm with enlarged loops even more. Heat distortion or certain
misalignments can therefore be easily compensated.
In relaxed condition such as damper opening the V-shaped
backup plate positioned inside the circular loop provided
additional lateral support. See picture1.
It protects the seal against damage or destruction from high gas
velocities and turbulence. In stressed condition such as damper
closing, a wide area of contact is created between seal and
mating surface providing an excellent sealing effect. See picture
2. The parts of the loops protruding sideways retain their curved
shape and are thus able to withstand high pressure levels.
The inernal V-shaped plate also acts as an end stop which limits
the seal compression and prevents an unintentional over-
deformation.
Byplacing one or more additional metal loops inside the circular
seal, its resilience can be adapted to suit specific service
conditions. Even when deformed by point loads(tramp materials)
the seal regains contact with the mating surface within a short
distance. Dust deposits and incrustations of the metal loop
simply break off due to seal flexing during damper closing.
Due to the wide area of contact created between seal and
mating surface a double sealing effect can be acheived with one
sealing element only. See picture 3. The second plane of
blades common in conventional Double Louver Dampers or
advanced Tandem Louver Dampers, is unnecessary. This
simplifies the whole damper design and reduces maintenance.
Also this brings 100% gastight with sealing air system at an
extremely competitive price.
5. New Sealnq Syslem
SAMWOO POWER SYSTEM CORPORATION
Normally each thermal power plant
requires several dampers such as a
guillotine damper, louver type damper, and
tandem lover damper to isolate or control
air/gas volume & path. Especially the flow
gas of a coal-fired thermal plant has a lot of
dust, therefore, all dampers located in gas
path have to be equipped with particular
feature of sealing as well as with less
pressure lose shape.
A Single Louver Damper which has single
skin-multi blades is normally used for
isolation or modulation purpose with leaf
type seal system that leads about 99.9%
tightness. This damper is required in
where no 100% tightness is required. A
tandem louver damper has two-layer of
blades which may allow the induced
sealing air from sealing air system to keep
100% tightness. This damper is used in
either gas or air path. The sealing type for
this damper is a leaf type sealing between
blades and a loop type sealing between
blade and frame. The chamber which is
made when the blades being closed is
very narrow, so it requires less air pressure
and volume.
A guillotine damper with lack-pinion part is
performed very well in especially gas path
where flows much dust away. It is
designed for electric driven actuator
especially and its blade operates very
smoothly and confidently. This damper is
used for isolation purpose as well as for
man safety during maintenance period.t
DAMPEPS lor Thermal Power Planls
SAMWOO POWER SYSTEM CORPORATION
DAMPEPS lor Thermal Power Planls
SAMWOO POWER SYSTEM CORPORATION
Dampers for DeNox plants are very
critical equipment to roll in the successful
operation of the plants. For controlling and
regulating of flue gases the dampers shall
be used under elevated temperature,
heavy particulate load and pressure. The
following dampers are normally required
for the DeNOx systems:
DeNOx Inlet Damper,
DeNOx Outlet Damper,
DeNOx Bypass Damper
The DeNOx Inlet Damper is normally
used to isolate the system, or to modulate
flue gases to the system. The DeNOx
Outlet damper also functions to regulate
the flow of heated air as well as to isolate
like Ihe Inlet Damper. The Bypass
Damper is applied to allow the system
flow to be directed to the DeNOx module.
It can be used in connection with the Inlet
Damper to control the flow during heat-up
service.
Generally the type of Inlet Damper is a
Tandem Louver, Double Louver or Flap,
and that of Outlet is a Single Louver,
Tandem Louver or Double Louver. The
Bypass Damper is normally a Tandem
Louver, Double Louver, or Guillotine
type. The Single Louver Damper can
reach upto 99.9% gas tight. And other
dampers with seal air system can be
100% tight. Both electric and pneumatic
type actuator can be used for the
dampers except for the Guillotine
Damper. The electric actuator is to be
recommended for the Guillotine Damper
for better and stable function of the
damper.
We are capable of fabricating what the
client demands and request. Especially
our unique patented design minimizes
any deformation or deflection caused by
thermal expansion, or pressure load.
Also patented sealing feature benefits
extremely excellent sealing efficiency.
Double louver damper, ND 6789 x 5390mm, for FGD plant. With seal air, 100% gastight in term of
UVV regulations. Seals are of the NICROFLEX-HIPERFORM, DBP, type.
DAMPEPS lor DeNox Planls
SAMWOO POWER SYSTEM CORPORATION
Louvor damper, ND 9000 x 10000mm, for the gastight isolation of a DeNOx catalytic reactor.
The new, patented, lattice supported single shell damper blades, DBP, minimise the pressure
drop across the open damper and no distortion occurs when exposed to high temperatures.
DAMPEPS lor DeNox Planls
SAMWOO POWER SYSTEM CORPORATION
FGD plants remove poisonous or harmful
gas components such as SO2 discharged
from a coal or oil fired boiler system.
Normally this gas component makes the
damper material corroded easily when the
gas being condensed or below dew point.
So the Dampers for FGD plants are very
critical equipment to protect the system or
the absorber.
The following dampers are normally
required for the FGD systems:
Booster Fan Inlet Damper,
FGD Inlet Damper
(Booster Fan Outlet Damper),
FGD Outlet Damper,
FGD Bypass Damper
The Booster Inlet Damper is used for
isolation application. Typically it is a Single
Louver Damper with carbon steel
fabrication. The FGD Inlet Damper with
normal carbon steel fabrication is used to
isolate flue gases to the system. Typically
it is a Single Louver Damper or Tandem
Louver Damper. The FGD Outlet damper
is placed behind the absorber, and
functions to isolate the bypass flow as well
as to protect the absorber at emergency
situation. Due to wet or moisture condition,
the material for this damper is high alloy;
nickel-chrome based stainless steel.
The Bypass Damper is applied to allow the
system flow to be directed to the stack. It
can be used in connection with the
Inlet/Outlet Damper to control the flow at
emergency.
Generally FGD Outlet Damper is a
Tandem Louver, Double Louver or Flap
Damper. The Bypass Damper is normally
a Tandem Louver, Double Louver or
Diverter Damper. Single Louver Damper
can reach upto 99.9% gas tight. And other
dampers with seal air system can be 100%
tight. Both electric and pneumatic type
actuator can be used for the dampers.
We are capable of fabricating what the
client demands and request. Especially
our unique-patented design minimizes any
deformation or deflection caused by
thermal expansion, or pressure load. Also
patented sealing feature benefits extremely
excellent sealing efficiency. Tandem-damper DN 5000 x 5000mm Man safe with seal air(100% tighteness)
DAMPEPS lor FGD Planls
SAMWOO POWER SYSTEM CORPORATION
lever flap damper for FGD inlet DN 2500 x 2500mm, man
safe with seal air (100% tightness)
Tandem Louver damper with seal air system (100% gastight) for FGD inlet DN 5200 x 5200mm, Seal type is NICROFLEX-MLO
Single Louver damper for Booster fan inlet DN 4500 x 6500mm,
Gas Tightness is 99.9% Leaf seal MLS
DAMPEPS lor FGD Planls
SAMWOO POWER SYSTEM CORPORATION
Di vert er, ND 2700 x 2700mm,
for off-shore gasturvine plant in
Denmark, powered by a hydraulic
actuator with fail safe function
St ack cap for gast urbi ne pl ant ,
ND 5400 x 5400mm.
The damper provides automatic pressure relief and opens without
external energy when a pre-adjustable pressure level is reached
In combined cycle gasturbine power plants
the turbine exhaust gas is directed either to
a waste heat recovery boiler or to the waste
gas stack by means of single blade diverter
dampers.
In case of smaller diverters, this blade is
pivoted directly by means of a peripherally
positioned drive shaft and straight levers,
while lager units are actuated by a central
shaft and internal toggle lever drive system.
Diverters can be insulated internally or
externally. To avoid heat radiation into the
closed off plant section, the blade itself
should be also insulated.
Patented features, our special designed
diverter is capable of performing very well
especially under high temperature and
velocity. The diverter with patented sealing
design and blade structure can be heated
up evenly to prevent any malfunction
caused by any thermal expansion or
deformation when the plant is running, with
high performance and stability to suit every
plant layout or new construction. And a
100% gas tight shut off is achieved in both
positions with sealing air system.
We also supply the following equipment:
diffusers, transitions, diverters, expansion
joints, blanking plates and guillotines, duct
extensions, exhaust stacks and silencers
(simple and combined cycle), louver
dampers, guillotines, and stack dampers.
DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls
SAMWOO POWER SYSTEM CORPORATION
Diverter, DBP, ND 2400 x 6400mm, during final assembly and testing in the works of work shap. This Diverter is
in service behind a LM 6000 General Electric gasturbine. The casing is intermally insulated and the damper is operated by an electric
actuator. Seal air and double seals of the NICROFLEX-MLO type proviide a 100% shut-off in both end positions. The patented, lattice
structure reinfored blade remains free of distortions when exposed to high, as well as rapidly fluctuating, gas temperatures.
Di vert er, ND 2400mm di a., for off-shore gasturbine plants in Norway.
This Diverter, as well as the one depicted overleaf, was equipped with the
NICPROFLEX-HOPERFORM sealing system
DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls
SAMWOO POWER SYSTEM CORPORATION
We have developed a complete bypass sytem for
gas turbine plants. Basis of the system is the
proven diverter with its patented lattice structure
reinforced damper blade as well as the patented
highly resilient Nicroflax-Hiperform sealing
system measure approx.30m. all parts are
provided with internal insulation. The dimensions
of all system components can be adapted to suit
different gas turbine frame sizes. The diverter
itself may be electrically or hydraulically operated
During turbine start up the diverter may be
utilized for volume control operations toward the
boiler. With double seal and seal air injection a
100% gastight. Man safe isolation is achieved. It
requested, an additional blanking plate guillotine
can be supplied.
DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls
SAMWOO POWER SYSTEM CORPORATION
We have developed the new NICROFLEX-
HIPERFORM sealing system for shut-off and
modulating dampers, more specifically however,
for combined cycle gas turbine diverters, The
tubular sealing elements (fig. 1, 2, and 3) are
made of a certain stainless steel and thus feature
a very high resilience.
In their standard configuration they accept
deformation of up to 30mm. Point loads caused
by tramp material are also rapidly absorbed and
contact with the landing bar is regained within
short distances.
The internal, V-shaped back up bar, stabilizes the
sealing element in uncompressed condition and
ensures that it can withstand vibrations caused
by high gas velocities or turbulence, while
operating in modulation mode. With a single
sealing arrangement (single sealing plane) an
area equivalent tightness of 99.98% is achieved.
Damper with two sealing planes and seal air
injection provide a 100% gastight, man safe shut-
off illustration 3 depicts a new, also patented seal
arrangement by means of which a 100% gastight
shut-off can be achieved with only one sealing
element.
In compressed conditions, e,g, damper closed,
the seal fattens and bulges outward, thereby
creating a broad area of contact able to
accommodate two sealing surfaces, Gas leakage
is prevented as usual by seal air injection.
The photos depict a diverter damper with internal
insulation, the blade featuring the patented lattice
type support structure with insulation and double
seal.
DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls
SAMWOO POWER SYSTEM CORPORATION
Large diverters are usually designed with an
international toggle lever drive mechanism. Of
advantage is that the actuation forces act in the
blade center and are hence evenly distributed
throughout the blade structure.
Also, in the end positions, when the blade is
subject to maximum pressure
Differential and its seals are making contact with
the landing bars, the toggle lever system
provides for an effective conversion of torque into
very high closing force.
Smaller diverters, however, can be operated
through a direct driven, pivoting shaft. The balde
may be equipped with either single or double
sided thermal
Insulation in order to reduce heat transmission
into the closed off section. The blade can be
electrically or hydraulically powered. During plant
start up volume control and gas flow modulation
is possible. The kinematics of the toggle lever
system in fact improves the modulation
characteristics of the blade.
Diverter blade with
Lattice structure
Reinforcement
Toggle lever system
With central drive shaft
Hydraulic or
Electric actuator
Landing bar for
Seal air charged
Sealing system
Seal air fan (with stand by)
Casing with internal or
External insulation
3 Diverter for the kayseri Power Station in Turkey Diverter ND 6000 x 2000mm, supplied to combined
cycle power station Degussa at Antwerp
DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls
SAMWOO POWER SYSTEM CORPORATION
We have developed and patented a new
diverter blade design for gas turbine
combined cycle plant service.

Generally, however, the design is eminently
suitable for all high temperature service
conditions. It has already proved
Itself in several different application. By
means of computer simulation the behavior of
the blade under particular service conditions
is exactly predictable in advance.

Together with also the new Nicroflex-
Hiperform sealing system, notable for its
great resilience and stability when subjected
to high gas velocities, this design is an
advantageous solution for even the largest
damper dimensions. Please refer to our
sealing features in this catalog.
The schematic illustration depicts the lattice
support structure of a high temperature
diverter blade. The blades cover plates are
floatingly and partially attached upon the
structure. This prevents their distortion when
exposed to uneven heating up. High
temperature gas can flow freely through the
lattice support structure. All its members heat
up evenly and maintain a uniform
temperature profile despite the fact that
changes of gas temperature can occur very
rapidly. Any deformation of the blades is thus
positively avoided.
Bearing Support of the main drive
shaft

The main drive shaft is supported by
maintenance free spherical sleeve bearings
fitted into dust tight housings. Neither the
exhaust gas nor the environment can ham
those bearings. The large, specially coated
spherical bearing surface ensure a smooth
movement of the bearing irrespective of
vibrations. The passages of the shaft through
the diverter casing are sealed by packing
glands with internal support ring.
DAMPEPS lor Gas Turbne Planls}Combned Cycle Planls
SAMWOO POWER SYSTEM CORPORATION
In combined cycle gasturbine power plants
the turbine exhaust gas is directed either to
a waste heat recovery boiler or to the
waste gas stack by means of single blade
diverter dampers.
In case of smaller diverters, this blade is
pivoted directly by means of a peripherally
positioned drive shaft and straight levers,
while lager units are actuated by a central
shaft and internal toggle lever drive
system. Diverters can be insulated
internally or externally. To avoid heat
radiation into the closed off plant section,
the blade itself should be also insulated.
Patented features, our special designed
diverter is capable of performing very well
especially under high temperature and
velocity. The diverter with patented
sealing design and blade structure can be
heated up evenly to prevent any
malfunction caused by any thermal
expansion or deformation when the plant is
running, with high performance and
stability to suit every plant layout or new
construction. And a 100% gas tight shut off
is achieved in both positions with sealing
air system.
We also supply the following equipment:
diffusers, transitions, diverters, expansion
joints, blanking plates and guillotines, duct
extensions, exhaust stacks and silencers
(simple and combined cycle), louver
dampers, guillotines, and stack dampers.
Gui l l ot i ne damper wi t h doubl e c abl e dr i ve. This design was developed in order to meet the requirements of very high
temperature service combined with extreme gas dust burdens. The main drive shaft moves both cables synchronuousoy in voth directions
thereby ensuring a smooth operation of the damper blade under extreme conditions. First developed in 1971, nearly 1000 units of its type
have been successfully put into service all over the world and it has since become a classic.
DAMPEPS lor Cemenl Planls
SAMWOO POWER SYSTEM CORPORATION
Gui l l ot i ne damper, VD 2200mm di a.,
to fit a circular waste gas duct of a cement kiln, equipped with
NICROFLEX-MLO seals. Design temperature: 350 degrees C.
Powered by rack and pinion system and electric Actuator.
Gui l l ot i ne dampers
during final assembly and testing at Rauenstein works. A total of
six units were supplied, two each with the dimensions 3200 x
4600mm, 4200 x 3200mm and 4000 x 4200mm, under cover of
one order, to the cement plant Hoping in Taiwan, one of the
largest limestone milling plants in the world.
Design temperature: 400 degrees C
Design pressure: 100 mbar
Dust burden: 1100 g/acbm
DAMPEPS lor Cemenl Planls
SAMWOO POWER SYSTEM CORPORATION
W are fully able to supply our dampers to
where other special dampers to be
requried such as steel smeter plants,
cement plants, chemical processing plants,
waste heat recovery plants as well as
power plants.
Goggle Valves provide a 100% gastight
isolation of gas mains in terms of UVV
regulations, without any sealing media.
The gastight shut-off is maintained even
upon loss of external engergy and
corresponds to that of a blind flange
connection. This damper is used for the
shut-off of blast furnace or coke gas mains.
Sickle isolators are used for handing blastf-
urnace exhaust or ther dust laden gases.
Dust sealing is hermetic and corresponds
to that of a blind flange connection in terms
of UVV regulations. A blind disc pivots
around a fixed point positioned outside the
duct. A coaxially moveavle sealing frame is
first retracted, thereby creating a slot
through whichthe disc travels. The sealing
frame is either actuated hydraulically or
electrically. Once locked, the seal between
disc and frame remains intact, even upon
loss of all extermal energy.
Toggle disc valves are used for the shut-off
gas mains. They are considered technica-
lly tight sealing valves. (to DIN 3230)
The high sealing efficiency is achieved by
means of an endless sealing element upon
which the valve disc is pressed down by
the action of the main levers when the
valve closes. On opening the valve, the
disc moves initially away from the seal in a
cozxial direction and is suvsequently
turned about by meanner, no wear takes
place at the seal. Toggle disc valves can
be powered by any type of actuator. In
combination with counterweights or sprin-
gs they may serve as emergency valves.
Toggl e di sc val ve, ND 3000mm di a., DVGW approved, valve in fully open
position. The valve is equipped with a double seal landing bar, thereby providing a
cavity into which Nitrogen is injected when the valve is closed. The Nitrogen pressure
is used to monitor the valve tightness continuously. The sealing element itself is fitted
tothe valve disc and is easily replaceable.
Isol at i on and gas modul at i on
syst em, DBP, ND 600 x17500mm,
for a gasturbine combined sycle power
plant. This damper is used dither, to isolate
the integrated bypass of the waste heat
recovery boiler completely, 17500mm is
facilitated by application of the new,
patented, lattice supported single shell
blade design. The blades are made up of
17500mm long latticed girders upon which
floating diaphragm cover plates are fitted.
DAMPEPS lor Clher Planls
SAMWOO POWER SYSTEM CORPORATION
Goggl e i sol at or, ND 3000mm di a.,
DVGW approved, with gastight castight casing, serving as main isolator in terms of UVV regulations,
in the gas supply duct of a blastfurnace gas fired boiler. The sealing frame, as well as goggle and
blind disc, are electrically actuated.
Si ckl e i sol at or, ND 2200mm di a.,
for cement factory, with electric actuator.
Louver damper, ND 6400 x 6400mm,
i n st ai nl ess st eel const ruct i on.
Each blade is driven separately by means of a fail safe
actuator and opens without any external energy.
Opening time is adjustable between 0,5 and 10 sec.
DAMPEPS lor Clher Planls
SAMWOO POWER SYSTEM CORPORATION
DESCRIPTION
Design points for Manual Damper are as follow.
Seismic : SSE 4.5g RIM
Safety : Seismic Cagory Design
Non Safety : Seismic Cagory Design
Environmental : 1 x 10^4 Gy
Safety Related 1E Equipment related
Safety Related non-metal related
In accordance with IEEE 323, 344, 382

Leakage Class
Frame Leak Class B~C
Seat Leak Class ~
In accordance with ASME AG-1-97, DA-5730
Butterfly Type : Frame - C, Seat - ~
Opposed Type : Frame - C, Seat -
Check Damper : Frame - C, Seat -
Back Draft Type: Frame - C, Seat -
Perfact Technical Data
Lead Time : 10 weeks after receipt of P/O

We, SWPS, already have supplying record to
Korean YGN #5/6, UCN #5/6 after
Equipment Qualification.
Material
* Frame & Flange : Carbon Steel
ASTM A36 or KSD3503 / JIS3101
* Blade : Galvanized Steel
ASTM A653 or KSD3506
* Shaft : Carbon steel or Stainless Steel
ASTM A36 or A276 / KSD3503 or 3706
* Blade & Shaft Seal : Gasket
EPDM or Neoprene
* Linkage & Link Arm : Carbon Steel
ASTM A36 or KSD3503 / JIS3101
* Bearing : Pillow Block Flang Mounted
Back Draft - Ball Bearing or Bushing
All Damper - Oil Impregnated Type
Coating & Painting
Painting or Hot Dipping Gavanizing
Fucntion - Manual Damper
Butterfly Type : Modulation & Isolation
Opposed Type : Only Modulation Type
Check Damper : Only Isolation Type
Back Draft Type:Only Isolation Type
Prototype Test Qualification
Pressure Drop :
* All Dampers : MAX0.1"WG(2.54mmAq)
* Down Flow CKD :
Opening Pressure - 1.7"WG(43mmAq)
Operating Load - 0.4"WG(10mmAq)
* Up Flow CKD :
Operating Load - 0.7"WG(18mmAq)
* Back Draft Damper
Operating Load - 0.27"WG(7 mmAq)

Flow Characteristics Test Qualification
* AMCA500 Standard 5.1, 5.2, 5.3, 5.4, 5.5
Only Modulation Damper Test
Cycle Repetition Test Qualification
* Isolation Type : Full Strock 2,100 Time
* Modulation Type : Full Strock 2,100,
20% Partial Strock 29,000 Time Test
Butterfly Damper Round Butterfly Damper
Round Check Damper
Check Damper
Round Butterfly Damper (Gear Type) Back Draft Damper
Check Damper (Multy Section)
Round Check Damper (Down Flow System) Oppose Blade Damper (Gear Type)
Manual Dampers lor Nuclear Power Planls
SAMWOO POWER SYSTEM CORPORATION
DESCRIPTION
The belows are Control Dampers'
design items.
Seismic : SSE 4.5g RIM
Safety, Seismic Cagory
N-safety Seismic Cagory
Environmetal : 1 x 10^4 Gy
Safety Related , 1E Equipment applied
Safety Related , non metalic applied
In accordance with IEEE 323, 344, 382

Leakage Class
Frame Leak Class B~C applied
Seat Leak Class ~
Based on ASME AG-1-97, DA-5730
Butterfy Type : Frame - C, Seat - ~
Opposed Type : Frame - C, Seat - -
Parallel Damper : Frame - C, Seat -
Any Special orders are available as per
your request. Perfect Technical Data
We, SWPS has already supplying record to
Korean YGN #5/6, UCN #5/6 after Wyle Lap.
.(US)'s Equipment Qualifcation.
Material
* Frame & Flange : Carbon Steel
ASTM A36 or KSD3503 / JIS3101
* Blade : Galvanized Steel
ASTM A653 or KSD3506
* Shaft : Carbon steel or Stainless Steel
ASTM A36 or A276 / KSD3503 or 3706
* Blade & Shaft Seal : Gasket
EPDM or Neoprene
* Linkage & Link Arm : Carbon Steel
ASTM A36 or KSD3503 / JIS3101
* Bearing : Pillow Block Flang Mounted
All Damper - Oil Impregnated Type

Coating & Painting
Painting or Hot Dipping Gavanizing
Fucntion - Control Damper
Butterfy Type : Modulation & Isolation
Opposed Type : Only Modulation Type
Parallel Damper : Only Isolation Type
Prototype Test Qualifcation
Pressure Drop :
* All Dampers : MAX0.1"WG(2.54mmAq)

Flow Characteristics Test Qualifcation
* AMCA500 Standard 5.1, 5.2, 5.3, 5.4, 5.5
Only Modulation Damper Test
Cycle Repetition Test Qualifcation
* Isolation Type : Full Strock 2,100 Time
* Modulation Type : Full Strock 2,100,
20% Partial Strock 29,000 Time Test
PSR (Pneumatic Spring Return) Actuators
Manufacure : Automax (USA)
Operation : pinion Gear Type
Pressure : 75~105 PSIG (5.3~8.4 kg/cm)
Solenoid Valve : 3Way Type ASCO GC
Positioners : 4~20mA - 3~15 PSIG Signal
Modulation Dampers Mounted
ESR (Electro Hydraulic Spring Return)
Actuator
Manufacture : ASCO GC or PMT (USA)
Operation : Cylinder Type
Voltage : 120VAC 1.5A
Limit S/W : DPDT Type 125VDC
Manufacture : Namco, Yongsung Electric,
Butterfly Control Damper wth ESR Actuator
Parallel Blade Control Damper wth PSR Actuator
ESR (Electro hydrauric Spring Return) Actuator
PSR (Pneumatic Spring Return) Actuator
DPDT Type Limit Switch
3 Way Type Solenoid Valve with Spring Return
Oposed Blade Control Damper with PSR Actuator Parallel Balade Control Damper - Supplied Quinsan NPP in China
Conlrol Dampers lor Nuclear Power Planls
SAMWOO POWER SYSTEM CORPORATION
DESCRIPTION
The general design items of control dampers
for safety and non safety are as follow.

Seismic : SSE 4.5g RIM
Safety, Seismic Cagory
N-Safety Seismic Cagory
Environmental : 1 x 10^4 Gy
Safety Related 1E Equipment
Safety Related non metalic applied
In accordancw with IEEE 323, 344, 382

Leakage Class
Frame Leak Class A~B
Seat Leak Class 0~
ASME AG-1-97, DA-5730
Buble Tight : Frame - A, Seat - 0
Class : Frame - B, Seat - 1 CFM / ft
Any Special orders are available as per
your request. Perfect Technical Data
Bubble Tqhl Conlrol Dampers lor Nuclear Power Planls
Material
* Frame : Carbon Steel
ASTM A36 or KSD3503 / JIS3101
* Blade : Carbo Steel & Galvanized Steel
ASTM A36 or KSD3503 / JIS3101
ASTM A653 or KSD3506
* Shaft : Carbon steel or Stainless Steel
ASTM A36 or A276 / KSD3503 or 3706
* Blade & Shaft Seal : Gasket
EPDM or Neoprene
* Linkage & Link Arm : Carbon Steel
ASTM A36 or KSD3503 / JIS3101
* Bearing : Pillow Block Flang Mounted
Ball Bearing Type

Coating & Painting
Painting or Hot Dipping Gavanizing
Fucntion - Control Damper
Buble Tighr Type : Only Isolation Type
Prototype Test Qualification
Pressure Drop :
* All Dampers : MAX0.1"WG(2.54mmAq)
Cycle Repetition Test Qualification
* Isolation Type : Full Strock 2,100 Time
PSR (Pneumatic Spring Return) Actuators
Manufacure : Automax (USA)
Operation : pinion Gear Type
Pressure : 75~105 PSIG (5.3~8.4 kg/cm)
Solenoid Valve : 3Way Type ASCO GC
ESR (Electro Hydraulic Spring Return)
Actuator
Manufacture : ASCO GC or PMT (USA)
Operation : Cylinder Type
Voltage : 120VAC 1.5A
Limit S/W : DPDT Type 125VDC
Manufacture : Namco, Yongsung Electric,
SA M WO O PO WER SYSTEM C O RPO RA TIO N
DPDT Type Limit Switch
3 Way Type Solenoid Valve with Spring Return
ESR (Electro hydrauric Spring Return) Actuator
Dual Disk Type
Bubble Tight Control Damper
wth PSR Actuator
PSR (Pneumatic Spring Return) Actuator
Round Dual Disk Type
Bubble Tight Control Damper
wth PSR Actuator
Round Dual Disk Type
Bubble Tight Control Damper
wth ESR Actuator
Dual Disk Type
Bubble Tight Control Damper
wth ESR Actuator
DESCRIPTION
The general design items are as
follow.
Seismic : SSE 4.5g RIM
Safety, Seismic Cagory
N-safety Seismic Cagory
Environmental : 1 x 10^4 Gy
Safety Related 1E Equipment applied
Safety Related non metalic applied
In accordancw with IEEE 323, 344, 382
Fucntion - GRD
* 1 Type : Supply Grille
3/4" Blade Spacing Double deflection
* 2 Type : Supply Register
3/4" Blade Spacing Double deflection
with Opposed Blade Dampers
* 3 Type : Return / Exhaust Grille
35~ 45 Fixed Blade
* 4 Type : Return / Exhaust Grille
35~ 45 Fixed Blade
with Opposed Blade Dampers
* 5 Type : Ceiling Diffuser
with Opposed Blade Dampers
5B Type - 2 Way Flow System
5C Type - 3 Way Flow System
5D Type - 4 Way Flow System
with Air-Intake Adaptor

Material
* Frame & Blade : Carbon Steel (Q Class)
ASTM A36 or KSD3503 / JIS3101
Galvanized Steeel
ASTM A653 or KSD3506
Stainless Steel
ASTM A240 or KSD3706 / JIS4304
Aluminum (T,R,S Class)
ASTM B221 or KSD6759 (6063T5)
* Flange Seal : Gasket Neoprene
* Opposed Blade Damper : Carbon Steel
ASTM A36 or KSD3503 / JIS3101
Galvanized Steeel
ASTM A653 or KSD3506
Stainless Steel
ASTM A240 or KSD3706 / JIS4304
Aluminum (T,R,S Class)
ASTM B221 or KSD6759 (6063T5)
Coating & Painting
Painting & Galvanized Steel
Test of Sound Measurement
Perfect Technical Data
Lead Time : 8 weeks after receipt of P/O
We, SWPS has already supplying record
to Korean YGN #5/6, UCN #5/6 afte
Wyle Lap.(US)'s Equipment Qualification.
Prototype Test Qualification

CODE & Standard : ADC-1062, GRD-84
ISO 5219 - Air distribution and air diffuser
Test of Pressure Requirement
Test of Area Velocity Factors
Test of Throw, Terminal Velocity and
Air Stream Drop
Throw-Trmanal Velocity and Drop
Mounting
* 1 Type : Supply Grille
Wall Mount, Ceiling Mounting
* 2 Type : Supply Register
Wall Mount, Ceiling Mounting
* 3 Type : Return / Exhaust Grille
Wall Mount
* 4 Type : Return / Exhaust Grille
Wall Mount
* 5 Type : Ceiling Diffuser
Ceiling Mounting
Supply and Exhaust Grille
Supply Exhaust Register
Return and Exhaust Grille
Return and Exhaust Register 2 Way Ceiling Diffuser 3 Way Ceiling Diffuser
4 Way Ceiling Diffuser Transfer Grille Adaptor for Ceiling Diffusers
GPD lor Nuclear Power Planls
SAMWOO POWER SYSTEM CORPORATION
LOUVER DESCRIPTION
SWPS Louvers are approved by
AMCA 500 Standard.
SWPS Louvers Type
* A Type : Fixed Louvers
* B Type : Operating Louvers
* C Type : Operating Dual Combination Louvers
* D Type : Back Draft Dual Combination
Louvers (Intake)
* E Type : Back Draft Dual Combination
Louvers (Exhaust)
* F Type : Emergency Opening Louvers
Material
* Frame & Blade : Aluminum
ASTM B221 or KSD6759 (6063T5)
* Screen Frame : Aluminum
ASTM B221 or KSD6759 (6063T5)
* Linkage : Aluminum or Steel Plate
ASTM B221 or KSD3503 (SS400)
* Coating Work : Painted
Kynar 500
* Screen : Stainless Steel Mesh 1.6x 1/2"
AMCA 500-94 Standard Test
...... * Free Area Design Certify
...... * Pressure Drop Test
...... * Air Leakage Test
...... * Water Penetration Test
...... * Operating Tes
SWPS "F" Type Louvers
* Opening at 0.2" WG Pressure for Spring Force
* Pressure Drop : Same Class to SKAT Louvers
* Material : Same Class to SKAT Louvers
* General : Operating Louvers
(Full Close or Full Open - 2 position)
* Emergency : Full Open Mode
* Closing : Stainless Steel Spring Force
SILENCER DESCRIPTION
* Designed
IEEE & ASTM Standard
* Material
Frame : Galvanized Steel
ASTM A653 or KSD3506
Caron Steel
ASTM A36 or KSD3503 / JIS3101
Split : Galvanized Steel
ASTM A653 or KSD3506
Caron Steel
ASTM A36 or KSD3503 / JIS3101
Insulatin : Glass Cloth with Glass Wool or
Glass Fiber
* Remark : Combusting Rating for the Silencer
acoustic fill and sealant is in accordace
with ASTM E84 and NFPA255, or
the equivalent
* Selection
Calculation of attenuator noise (PWL)
Sound loss calculation
Sum of the returning noise
Decide in-door NC level
Noise-Loss-NC level
Application
Louvers for Nuclear Power Plant
Silencers for Nuclear Power Plant
SWPS PENTHOUSE
Where the free area is short, Penthouse offers broad free area from 4 way.
SWPS SOUND LOUVERS
Sound louvers attenuate the noise from machine room etc. to outside of it.
Sound Louvers let the air flow free but attenuate the noise.
This sound louvers are for multi purpose like the above.
Ducl Accessares lor Nuclear Power Planls
SAMWOO POWER SYSTEM CORPORATION
SAMWOO POWER SYSTEM CORPORATION
HEAD OFFICE
#609 Center Plaza, Songdo-Dong, Yeonsu-Gu Incheon, Korea, (Zip Code : 406-840)
Tel : +82-70-7603-3500 (rep.) / Fax : +82-32-858-2536
FACTORY
- Namdong : #653-6 Kojan-Dong, Namdong-Gu Incheon, Korea, / Tel : +82-70-7603-3506
- Western : #612-1 Deagok-Dong, Seo-Gu Incheon, Korea, / Tel : +82-70-7603-3507
Site : www.swps.kr
Mail : swps@swps.kr