Introduction Labeling efficiency energy Inverter Daikin Purifiers Catalytic air pirifiers

Domestic range Cold only/ Inverter Wall-mounted units G anf F Inverter series. 1x1. Multi-Inverter units Multiple external units Internal units Cooling capacity Heat pump/ Inverter Wall-mounted Ururu/Sahara units Wall-mounted UX1 series units Wall-mounted G and F series units Soil units Soil - Ceiling units Multi-Inverter units External units Internal units Cooling loads Cooling capacity Super Multi-Inverter units Multiple external units Internal units maximum length of pipe Capacity tables Altherma Heat pump/ Inverter System of instantaneous cooling and domestic hot water (WF)

SkiAir range Comfort Inverter/ heat pump Ducts units 4 way cassette 60x60 Round flow of cassette units Ceiling horizontal units wall-mounted split units Super Inverter/ Heat pump Ducts units Cassette Round flow of cassette units Sight Cassette units Ceiling Horizontal units Wal-mountedl units

SkiAir range Units of high pressure pipe Industriales range MINICHILLER Coolers for residential use Fan Coils

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Labeling Energy Efficiency


The labeling of energy efficiency is part of a European program for climate change that focuses on energy savings as a method to reduce CO2 emissions and therefore to comply with the agreements of the Kyoto Protocol. With this program, the European Commission hopes that increased awareness will make customers buy the product more economical (and ecological) that meets your needs.

What is it?
The energy efficiency label provides information about energy consumption of the unit. Air conditioning units (with a cooling capacity of 12Kw) are classified into seven different categories (from A to G), according to their energy consumption, and are encoded with different colors, depending on the category they belong to. The units that consume less energy are included in category A, which is indicated by green arrow on the label, while those who consume more units belonging to the G class, indicated with a red arrow on the label. In this way, the end user can compare the models with similar units from different brands.

When?
The label is required since the end of June 2004 for devices with power not exceeding 12.0 kW refrigeration.

What does it say on the label?


The logo and name of the manufacturer and the name of the external or internal (for applications in multiple assemblies, Daikin prefer to mention only 1 outdoor unit with up to 2 indoor units (wall).

Level of energy efficiency of the unit in cooling mode (EER):

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Power Cooling
Indication of the annual energy consumption
This figure indicates the approximate amount of energy the unit consumes in a year, based on a standard for household application. The annual consumption is calculated by multiplying the total power consumed by an average of 500 hours for one year in cooling mode and full load. To estimate the total cost of energy consumption for one year, simply multiply this amount by the rate of electricity. Power is defined as the cooling capacity of cooling equipment in kW, operating in cooling mode and at full load. It is important to acquire a unit of air conditioning system with a rated output sufficient for your cooling needs and cooling or heating. Too large a unit can make frequent stops in and start the unit, which reduces its life. Conversely, too small a unit may not meet your needs for heating or cooling. To determine the appropriate power, contact your dealer.

Energy Efficiency Factor (ENERGY RATIO EFICIENCY, EER)


Is the cooling power of the unit divided by the amount of electricity that the unit needed to produce it (total power). In other words, the higher the EER, the greater the difference in the unit. Type of drive system for cooling only or cooling / heating. Cooling mode: air cooled or water.

Coefficient of performance (COEFFICIENT OF Performance, COP)


Is the heating power of the unit divided by the amount of electricity that the unit needed to produce it (total power). In other words, the higher the COP, the greater the energy difference of the unit.

Performance of the unit in heating mode (COP):

Heating power
Power by means of heating the heating capacity of heat pump equipment in kW, operating in heating mode and load.

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Daikin Inverter
New technologies
In 1982, Daikin established the first air conditioning system with INVERTER technology throughout the world and began to sell systems Variable Refrigerant Volume (VRV), a new technology that improves the conventional air conditioning systems in both cooling and heating. The system of regulation varies Inverter rpm electric motor of the compressor. This will provide the defendant and the power consumption is proportional. As a result, and once up, the unit is changing its ability and consume according to demand. This translates into a continuous operation without stopping, providing a uniform temperature and a significant energy savings. The time that the team needs to reach the desired temperature (up system) is shorter than in conventional systems.

New Daikin compressors


Daikin is a unique brand that has developed new specific compressors in order to apply this technology successfully. Has developed a new Spiral Asimtrico Horizontal Compressor, which get much airconditioning equipment more reliable, efficient, quieter and with lower consumption. At the technical level, it improves performance by eliminating spiral volumetric compressor pulsations. This reduces the noise level and through the change of position in areas of high and low pressure ends with lubrication problems. Swing compressor to higher performance and lifetime. With it, resolved the problems of sealing and lubrication of the rotary compressor. This new compressor is driven by an innovative engine continued running smaller, more efficient and more powerful. Reduces leakage and reduces the heat, preventing the decomposition of the oil.

Refrigerant R-410 A
Daikin, which is currently the only company in the world with joint manufacturing of air conditioning and refrigerant gases. Thanks to his constant research, with its full range, chlorine-free with higher performance (high COP), respecting the environment (zero ODP). Daikin has designed its new equipment with R-410 A to achieve higher returns to R-22. The refrigerant R-410 to use the same oil that the ether R-407C and has another important advantage in practice is azeotropic, so when there is a leak remains R'410 A, making it easy to retrieve and reused. With a capacity of heat transfer a 40% higher than the R-22 and R-407C, the teams with R-410 has a 15% better performance than the R-407 C. Thus, Daikin, faithful to its policy of technological innovation, presents its full range of domestic R-410 A.

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Inverter technology. Maximum efficiency, with the same consumption


The use of inverter technology ensures maximum comfort and performance. DC INVERTER system allows the distribution of the refrigerant is done accurately. By varying the speed of rotation of the compressor responds proportionally to the demand of the different parts of the building. That possibility of regulating the compressor reduces the power consumption, achieving energy savings of more than 30%. Moreover, it allows precise control of heating or cooling capacity at all times. This system provides significant improvements in aspects such as consumption, performance and accuracy of temperature with respect to conventional systems. Its new engine with neodymium magnet material, ensures a higher torque with lower consumption (between 20% and 40% less). The DC Inverter incorporates new electronic controls and a new microprocessor that integrates a number of parameters, providing the most appropriate solution to every moment.

PAM technology. Maximum comfort with minimum consumption.


Control PAM (pulse amplitude modulation) ensures full use of the power and controls the motor's voltage, even in high load conditions, which yields a pair of high rotational speed. There is a substantial energy savings by reducing the switching frequency of the noise and switching losses.

Aesthetics and design


Wall units Daikin combine functionality with design and aesthetics more current. Its flat panel improves air distribution, increasing the capacity of the unit and reduce its noise level.

Short cycle start


Inverter control enables the desired temperature much faster than units with inverter technology, in fact, the start-up time is reduced by one third.

30% less energy consumption


The inverter control detects changes in both internal and external conditions in seconds and adjusts the interior temperature to compensate for these changes. This rapid response reduces power consumption by more than 30% compared to systems with inverter technology.

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Purifiers
Functions of the unit 1. Automatic power saving The airflow is adjusted to the amount of dirt in the air. When the purified air, the power saving mode is activated. Other benefits 2. Silent Mode can sleep in absoluThe new generation of te silence. cleaners used first tech- o Large air flow with very low noise level. 3. High power turbo mode is used nology to download o It is portable and has a remote control. Flash Stream. o It generates negative ions. where a rapid air purification. o Child Lock. o Easy to clean. 4. monitor the level of purification How does the Flash (dust) indicates the level of air Streamer? pollution detected by the sensor of Download the Flash Streamer unit delivers dust. high power electron oxidation at high speed and in 3D. These elec5. so pollen can be easily modified trons to collide with and bind the components of air particles to retain the configuration of air decompose odor. flow replace the filter annually electrostatic dust collector (front) and 6. Negative ion mode indicates that the filter for Photocatalyst titanium apatite (back) remains highly they are generating negative ions. effective. 7. operating mode the light signal What is achieved? indicates that the unit is operating. 1. Flash streamer quickly decomposes and removes the bad smell of snuff. 8. Stop Timer lets you program the Down 95% or more of harmful substances such as ammonia, aceshutdown of the unit 1.2 or 4 hours. taldehyde and acetic acid of cigarriillos and reduces the concentration of formaldehyde. The effects of decomposition are very 9. indicator purification indicates durable. whether it is necessary to clean the Note: Flash drive does not remove certain harmful components such as snuff of carbon monoxide. ioniser. 10. Filter replacement indicator 2. The synergy between the Flash and the streamer Photocatalyst removes bacteria faster than previous models. whether to replace the filter. 11. monitor the level of purification (color) indicates the level of air pollution detected by the sensor odor. 12. sensor dust 3. When exposed filter titanium apatite to Flash drive, Photocatalyst activity is two times more efficient than conventional ultraviolet lamps. Removes 99.99% of bacterium in 4 hours, 6 times faster than conventional systems.

13. odor sensor These sensors control the air quality 4. Anti-virus filters. 99.99% of disables in the room and automatically set viruses collected in one minute, provithe required level of performance. ding a healthier environment. 5. Disable the 99.6% of dust mites and pollen filter through the titanium apatite. Model MC707VM-S / Unit 480,00
www.alvarezhortas.es

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

Air Aconditioning, Catalog - Tariff

System of three filters Daikin The prefilter removed the larger particles and pet hair, the positively charged particles ioniser contaminated before they reach the ion filter roll. This filter contains two layers of electrostatic filter and a filter of titanium oxide. Section electrostatic trapping micro particles and positively charged. The Photocatalyst Activated by light inverter reacts with titanium oxide to oxidize harmful gases and unpleasant odors and germs and bacterium. We breathe about 22,000 times a day, Daikin purifiers offer the purest air in our homes and workplaces. Eliminates the source of many allergies: dust, pollen, pet hair ... Destroys 99.9% of the pollutants.

Photocatalytic air purifiers


Cleansers Voltage Dimensions Weight Consumption (according to mode) Turbo High Means Low Silent Turbo High Means Low Silent Turbo High Means Low Silent High Wide Background Mm Mm Mm Kg W W W W W m3/ h m3/ h m3/ h m3/ h m3/ h dBA DBA DBA DBA DBA MC704AVM I/ 220V 498 400 198 7,0 52 24 20 17 15 420 270 210 120 60 47 36,5 32 24 16

Cleaning capacity (depending on mode)

Sound pressure

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Domestic range

Heat pump

Wall-mounted URURU-SAHARA series units Inverter/ Split

Adequacy of moisture Automatic control of humidity. The operation Ururu (Wetting) and Sahara (Deshumectacin) is made uniform throughout the stay. Moist air creates a better feeling of warmth, comfort.

Role of renewal. Air exchange inside-out. Any moisture recovered from the air is used for the interior. The renewal of air hose is included.

The air conditioner of the future! To enjoy the maximum comfort, something more is needed to control the temperature. The new generation of air conditioning can: 1. Temperature Control 2. Humidity control 3. Ventilation Control operations of heating and humidity control maintain sufficient comfort in all seasons. Moreover 1. Filter purifying titanium apatite. 2. 3D airflow. URURU SARARA series TXR28E FTXR28E + RXR28E = 726,00 + 852,00 TXR242E FTXR42E + RXR42E = 851,00 + 1.019,00 TXR50E FTXR50E + RXR50E = 1.237,00 + 1.619,00 / Unit 1.578,00 1.870,00 2.856,00 Air is supplied from outside is filtered and weighed before being taken to the climate.
www.alvarezhortas.es

Moisture Exchange No need for water injection. All moisture is taken from the exterior and the interior is provided.

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

Air Aconditioning, Catalog - Tariff

Wall split set Ururu-Sahara series


Set Capacity Cooling Heating Consuption Conexions Voltage N wires interconnecting EER COP Labering energy efficiency Annual energu consumption Cooling Heating Liquid Gas Min-Nom-Max Min-Nom-Max Mjn-Nom-Max Min-Nom-Max W Kcal/h W Kcal/h W W Mm Mm TXR28E 1.550-2.800-3.600 1.333-2.408-3.096 1.300-3.600-5.000 1.118-3.096-4.300 250-560-800 220-700-1.410 6,4 (1/ 4) 9,5 (3/ 8) I/ 200V 3+T 5,00 5,14 A A 280 TXR42E 1.550-4.200-4.600 1.333-3.162-3.956 1.300-5.100-5.600 1.118-4.386-4.816 260-1.050-1.320 220-1.180-1.600 6,4 (1/ 4) 9,5 (3/ 8) I/ 200V 3+T 4,00 4,32 A A 525 TXR50E 1.550-5.000-5.500 1.333-4.300-4.730 1.300-6.000-6.200 1.118-5.160-5.332 260-1.460-1.800 230-1.510-1.770 6,4 (1/ 4) 9,5 (3/ 8) I/ 200V 3+T 3,42 3,97 A A 730

Cooling Heating Cooling Heating Cooling

kWh

wall internal units Ururu-Sahara series


Wall-mounted internal units Air flow Speed fan Dimensions Cooling Heating High Wide background Cooling Heating (A/B/SB) (A/B/SB) (A/B/SB) (A/B/SB) m3/ min m3/ min N mm mm mm Kg dBA dBA TFXR28E 11,1/ 6,5/ 5,7 12,4/ 7,3/ 6,5 5+A+S 305 890 290 14,0 39/ 26/ 23 41/ 28/ 25 FTXR42E 12,4/ 6,8/ 6,0 12,9/ 7,7/ 6,8 5+A+S 305 890 209 14,0 42/ 27/ 24 42/ 29/ 26 TFXR50E 13,3/ 7,3/ 6,5 14,0/ 8,3/ 7,3 5+A+S 305 890 209 14,0 44/ 29/ 26 44/ 31/ 28

Weight Sound pressure

External units
External units Compressor type Refrigerant Dimensions RXR28E SWING R-410 A 693 795 285 48,0 46/ 46/ 10 RXR42E SWING R-410 A 693 795 285 48,0 48/ 48/ 10 RXR42E SWING R-410 A 693 795 285 48,0 48/ 50/ 10 -

High Wide background Cooling Heating (A/ B) (A/ B)

Weight Sound pressure Refrigerant load Additional load

mm mm mm kg dBA dBA m gr/ m

Note: 1 .- Energy Efficiency Label: from A (most efficient) to G (least efficient) 2 .- Annual energy consumption: based on an average usage for 500 hours of operation per year at full load (= nominal conditions) Note: capacities are based on the following conditions: 1 .- Cooling: indoor temperature 27 CBS, CBH 19th, outdoor temperature 35 CBS 2 .- Heating: indoor temperature 20 CBS, CBS outdoor temperature 7 , 6 CBH. 3 .- refrigerant piping length: 7.5 m, power: 220/1/50 measurement noise is carried out in an anechoic chamber at a distance of 1 meter from the unit.

TXR28E Maximum pipe length (L) Maximum level diffrence (H) m m 10 8

TXR42E 10 8

TXR50E 10 8

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Heat pump
Wall-mounted UX1 series units Inverter Split
Features 1. Sleek and stylish compact: Only 150 mm deep. 2. Extremely quiet: only 22 dB (A) (Model 25 running super low). 3. New slide opening system that improves the distribution of airflow. Cooling mode The flap is fixed in an almost horizontal position, which prevents direct flow of cold air on people and to homogenize the temperature of the room. Heating mode The flap turned down, watch an almost vertical position, directing the flow of hot air directly at the feet of people avoiding the annoying sensation of cold feet.

UX1 series TXG25EW Inverter White FTXG25EW + RXG25E = 608,00 + 705,00 TXG25ES Inverter silver FTXG25ES + RXG25E = 608,00 + 705,00 TXG35EW Inverter White FTXG35EW + RXG35E = 680,00 + 814,00 TXG35ES Inverter silver FTXG35ES + RXG35E = 680,00 + 814,00

/ Unit 1.313,00 1.313,00 1.494,00 1.494,00

Air purifier filter totocataltico of titanium apatite Effectively absorbs microscopic particles, decomposes odors and even kills bacteria and deactivates viruses. First filter air purifier in the world that employs a Photocatalyst titanium apatite, which limina odors and bacteria and deactivates viruses.
www.alvarezhortas.es

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

Air Aconditioning, Catalog - Tariff

Wall split set UX1 series


Wall split set Capacity Cooling Heating Consuption Conexions Voltage N wires interconnecting EER COP Labering energy efficiency Annual energy consumption Cooling Heating Liquid Gas Min-Nom-Max Min-Nom-Max Mjn-Nom-Max Min-Nom-Max W Kcal/h W Kcal/h W W Mm Mm TXG25EW 1.300-2.500-3.000 1.118-2.150-2.580 1.300-3.400-4.500 1.118-2.924-3.870 300-620-950 290-825-1.420 6,4 (1/ 4) 9,5 (3/ 8) I/ 200V 3+T 4,03 4,12 A A 310 TXG25ES 1.300-2.500-3.000 1.118-2.150-2.580 1.300-3.400-4.500 1.118-2.924-3.870 300-620-950 290-825-1.420 6,4 (1/ 4) 9,5 (3/ 8) I/ 200V 3+T 4,03 4,12 A A 310 TXG35EW 1.400-3.500-3.800 1.204-3.010-3.268 1.400-4.200-5.000 1.204-3.612-4.300 300-1.060-1.290 310-1.135-1.560 6,4 (1/ 4) 9,5 (3/ 8) I/ 200V 3+T 3,30 3,70 A A 530 TXG35ES 1.400-3.500-3.800 1.204-3.010-3.268 1.400-4.200-5.000 1.204-3.612-4.300 300-1.060-1.290 310-1.135-1.560 6,4 (1/ 4) 9,5 (3/ 8) I/ 200V 3+T 3,30 3,70 A A 530

Cooling Heating Cooling Heating Cooling

kWh

Wall internal units UX1 series


Wall internal units front panel color Air flow Speed fan Dimensions TFXG25EW Matt white crystal 7,4/ 4,4/ 3,7 7,7/ 6,0/ 5,0 5+A+S 275 840 150 9,0 38/ 25/ 22 38/ 28/ 25 FTXG25ES Matt crystal silver 7,4/ 4,4/ 3,7 7,7/ 6,0/ 5,0 5+A+S 275 840 150 9,0 38/ 25/ 22 38/ 28/ 25 TFXG35EW Matt white crystal 7,9/ 4,7/ 4,1 7,9/ 6,0/ 5,1 5+A+S 275 840 150 9,0 39/ 26/ 23 39/ 29/ 26 FTXG35ES Matt crystal silver 7,9/ 4,7/ 4,1 7,9/ 6,0/ 5,1 5+A+S 275 840 150 9,0 39/ 26/ 23 39/ 29/ 26

Cooling Heating High Wide background Cooling Heating

(A/B/SB) (A/B/SB)

Weight Sound pressure

(A/B/SB) (A/B/SB)

m3/ min m3/ min N mm mm mm Kg dBA dBA

External units
External units Compressor type Refrigerant Dimensions RXG25E SWING R-410 A 550 765 285 32,0 46/ 43 47/ 44 10 20 RXG35E SWING R-410 A 550 765 285 32,0 47/ 44 48/ 45 10 20

High Wide background Cooling Heating (A/ B) (A/ B)

Weight Sound pressure Refrigerant load Additional load

mm mm mm kg dBA dBA m gr/ m

Note: 1 .- Energy Efficiency Label: from A (most efficient) to G (least efficient) 2 .- Annual energy consumption: based on an average usage for 500 hours of operation per year at full load (= nominal conditions) Note: capacities are based on the following conditions: 1 .- Cooling: indoor temperature 27 CBS, CBH 19th, outdoor temperature 35 CBS 2 .- Heating: indoor temperature 20 CBS, CBS outdoor temperature 7 , 6 CBH. 3 .- refrigerant piping length: 7.5 m, power: 220/1/50 measurement noise is carried out in an anechoic chamber at a distance of 1 meter from the unit. TXG25EW/ ES Maximum pipe length (L) Maximum level diffrence (H) m m 20 15 TXG35EW/ ES 20 15

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Heat pump
Wall-mounted G and F series units Inverter/ Split

Features 1. The new unit FTXS-G, Plat Panel with new design has a modern appearance and easy to clean thanks to its flat panel. 2. Lightweight and compact. 3. Unification of units, both in cold and only heat pump. 4. Consumes up to 30% less energy than units Inverter. 5. The motion sensor reduces consumption in the rooms where there are no people. 6. The dual drive air ensures a better distribution of it throughout the room.

Powerful operation mode maximizes air flow for 20 minutes (for example, when you come home on a hot day, it is necessary to maximize the cooling of the atmosphere). After this period, the unit automatically returns to its previous configuration. The Night mode allows you to prevent any sudden change in temperature raising / lowering the temperature carefully before the air conditioning system is stopped so that more can sleep comfortably. Units will have the new G series ECONO mode (power saving mode). This mode reduces power consumption and maximum operating current by approximately 30% during the system boot. This wall unit is equipped with a filter air purifier apatite photocatalytic titanium.

G and F series TXS20J2 FTXS20J2+RXS20J2= 496,00+525,00 TXS25J2 FTXS25J2+RXS25J2= 497,00+587,00 TXS35J2 FTXS35J2+RXS35J2= 521,00+679,00 TXS42J2 FTXS42J2+RXS42J2= 635,00+828,00 TXS50J2 FTXS50J2+RXS50J2= 883,00+1.156,00 TXS60F FTXS60G+RXS60F= 1.134,00+1.228,00 TXS71F FTXS71G+RXS71F= 1.403,00+1.571,00

/ Unit 1.021,00 1.084,00 1.200,00 1.463,00 2.039,00 2.362,00 2.974,00


www.alvarezhortas.es

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

Air Aconditioning, Catalog - Tariff

Wall split set, G and F series


G y F series, s et Capacity Cooling Heating Consumption Conexions Voltage N wir es in terconn ectin g EER COP Labeting energy eff icien cy Ann u al en ergy con sumption Cooling Heating Liqu id G as Min-Nom-Max Min-Nom-Max Mjn-Nom-Max Min-Nom-Max W Kcal/h W Kcal/h W W mm mm TXS20J2 1 .3 00-2 .000-2 .6 00 1 .1 18-1 .720-2 .2 36 1 .3 00-2 .700-4 .1 00 1 .1 18-2 .322-3 .5 26 300-4 70-82 0 290-6 30-1.2 90 6,4 (1/ 4) 9,5 (3/ 8) I/ 20 0V 3+T 4 ,2 6 4 ,2 9 A A 2 35 TXS25J2 1.300-2.500 -3.00 1.118-2.150-2.580 1.300-3.400-4.500 1.118-2.924-3.870 300 -550-960 290 -750-1.430 6,4 (1/ 4) 9,5 (3/ 8) I/ 200V 3+ T 3,55 4,53 A A 275 TXS35J2 1 .400-3.400-3 .800 1 .204-2.924-3 .268 1 .400-4.000-5 .000 1 .204-3.440-4 .300 300-870-1 .2 70 310-960-1 .5 60 6 ,4 (1 / 4) 9 ,5 (3 / 8) I/ 200V 3+ T 4 ,02 4 ,17 A A 435 TXS50J2 900 -5.00-5.800 774 -4.300-4.988 900 -5.800-7.500 774 -4.988-6.450 400 -1.520-1.770 435 -1.570-2.200 6,4 (1/ 4) 9,5 (3/ 8) I/ 200V 3+ T 3,29 3,69 A A 760 TX S6 0G 900-6 .0 00-6 .700 774-5 .1 60-5 .762 900-7 .0 00-8 .000 774-6 .0 20-6 .880 440-1 .9 90-2 .400 400-2 .0 40-2 .810 6 ,4 (1/ 4) 9 ,5 (3/ 8) I/ 200V 3+ T 3 ,02 3 ,43 B B 9 95 TXS71G 900 -7.100 -8.000 774 -6.106 -6.880 900 -8.500 -9.500 774 -7.310 -8.170 570 -2.350 -3.200 520 -2.550 -3.820 6,4 (1/ 4 ) 9,5 (3/ 8 ) I/ 200V 3 +T 2,81 3,23 B C 1.175

Cooling Heating Cooling Heating Cooling

kWh

Iall internal unit, G and F series


D and B series, intern al un it s Air flow Speed f an Dimen sion s Coolin g Heating High Wide Backgroun d Coolin g Heating (A/ B / SB) (A/ B / SB) (A/ B / SB) (A/ B / SB) m 3/ h m 3/ h N mm mm mm Kg dBA dBA FTXS20 J2 9,0/ 4 ,7/ 3,9 9,3/ 5 ,8/ 5,0 5+ A+ S 2 95 8 00 2 15 9 ,0 38/ 2 5/ 22 38/ 2 8/ 25 FT X25J2 9,0/ 4,7/ 3,9 9,6/ 5,8/ 5,0 5+A +S 295 800 215 9,0 38/ 25/ 22 38/ 28/ 25 FTX35J2 1 0,0/ 4,8/ 4,0 1 0,3/ 6,0/ 5,2 5+ A+ S 295 800 215 9,0 39/ 26/ 23 39/ 29/ 26 FTX S5 0J2 11,4/7 ,1/ 6,2 10,9/ 7,4/ 6,3 5 +A+ S 2 95 8 00 2 15 9 ,0 44/ 35/ 32 42/ 33/ 30 FTXS60F 16,2/ 11,5/ 10,0 17,4/ 12,8/ 10,5 5+ A+S 290 1.050 238 12,0 45 / 36/ 3 3 44 / 35/ 3 2 FTXS71F 17,4/ 11 ,9 / 11,2 21,5/ 14 ,4 / 13,3 5+ A+ S 290 1.050 238 12,0 46/ 3 7/ 34 46/ 3 7/ 34

Weigh t Sou nd pr essu re

External units
Ex ternal u nits Compressor type Refr igeran t Dimen sion s R XS20J2 SWIN G R-410 A 550 765 285 30,0 46 / 43 47 / 44 10 20 RX S2 5J2 SWIN G R -41 0 A 550 765 285 30,0 46/ 43 47/ 44 10 20 RXS35J2 SWING R-410 A 55 0 76 5 28 5 32 ,0 47/ 44 48/ 45 10 20 R XS50J2 SWIN G R-410 A 735 825 300 49,0 47/ 44 48/ 45 10 20 RXS60 F SWIN G R -41 0 A 735 825 300 5 3,0 49/ 4 6 49/ 4 6 10 20 RXS71F SWING R-410 A 735 825 300 55,0 5 2/ 49 5 2/ 49 10 20

High Wide Backgroun d Cooling Heating (A/ B ) (A/ B )

Weigh t Sou nd pr essu re Refr igeran t load Addition al load

mm mm mm Kg dBA dBA m gr/ m

Note: 1 .- Energy Efficiency Label: from A (most efficient) to G (least efficient) 2 .- Annual energy consumption: based on an average usage for 500 hours of operation per year at full load (= nominal conditions) Note: capacities are based on the following conditions: 1 .- Cooling: indoor temperature 27 CBS, CBH 19th, outdoor temperature 35 CBS 2 .- Heating: indoor temperature 20 CBS, CBS outdoor temperature 7 , 6 CBH. 3 .- refrigerant piping length: 7.5 m, power: 220/1/50 measurement noise is carried out in an anechoic chamber at a distance of 1 meter from the unit.

T XS20J2 Maximu m pipe length (L) Maximu m level diffrence (H ) m m 20 15

T XS2 5J2 20 15

T XS35 J2 20 15

T XS50J2 30 20

T XS6 0F 30 20

TXS71F 30 20

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Heat pump
Soil units Inverter / Split
Filter purifying titanium apatite Photocatalytic air purifier filter of titanium apatite. Effectively absorbs microscopic particles, decomposes odors and even kills bacteria and deactivates viruses. Plus: 1. Energy savings: Cals A. It increases substantially the EER and COP. 2. Extending the range to -10 C to -15 C for heating. 3. This unit can be placed against a wall or embedded in it for a more elegant appearance. Remote redesigned 1. 5-speed. + Quiet fan. 2. Programmer hours (7 days). 3. 4 shares per day. 4. On / Off & Temperature Control. 5. Copy function.

Mando a distancia rediseado 1. 2. 3. 4. 5. 5 veloc. ventilador + Funcin silenciosa. Programador horario (7 das). 4 acciones/ da. On/Off & Control Temperatura. Funcin copia.

The automatic vertical orientation function automatically moves the flaps up and down, thereby ensuring a uniform distribution of air throughout the room. The vertical fin angle broad, slightly curved, offer extensive coverage of the airflow, thus maximizing the effectiveness of cooling regardless of the part of the room in which it is located inside the unit. The fins can be adjusted manually.

The remote features a weekly timer, which allows to adapt the functioning of the unit according to their personal needs, and a memory that can be programmed to control the daily operation of the system can be set to 4 different actions per day.

VXS-F series VXS25F FVXS25F+RXS25G= 1.146,00+587,00 VXS35F FVXS35F+RXS35G= 1.275,00+679,00 VXS50F FVXS50F+RXS50G= 1.394,00+1.156,00

/ Unit 1.733,00 1.954,00 1.2.550,00


www.alvarezhortas.es

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

Air Aconditioning, Catalog - Tariff

Conjunto split de suelo


Soil split set Capacity Cooling Heating Consumption Conexions Voltage N wires interconnecting EER COP Labeting energy efficiency Annual energy consumption Cooling Heating Lquid Gas Min-Nom-Max Min-Nom-Max Mjn-Nom-Max Min-Nom-Max W Kcal/h W Kcal/h W W mm mm VXS25F 1.300-2.500-3.000 1.118-2.150-2.580 1.300-3.400-4.500 1.118-2.924-3.870 300-700-920 290-900-1.390 6,4 (1/ 4) 9,5 (3/ 8) I/ 200v 3+T 4,39 4,30 A A 285 VXS35F 1.400-3.500-3.800 1.204-3.010-3.268 1.400-4.500-5.000 1.204-3.870-4.300 300-1.090-1.250 310-1.320-1880 6,4 (1/ 4) 9,5 (3/ 8) I/ 200v 3+T 3,43 3,69 A A 510 VXS50F 900-4.800-5.300 774-4.128-4.558 900-6.000-7.700 774-1.700-2.350 450-1.700-2.350 310-1.870-2.600 6,4 (1/ 4) 9,5 (3/ 8) I/ 200v 3+T 3,23 3,63 A A 775

Cooling Heating Cooling Heating Cooling

kWh

Unidades interiores de suelo


Soil internal units Air flow Speed fan Dimensions Cooling Heating High Wide Background Cooling Heating (A/ B/ SB) (A/ B/ SB) (A/ B/ SB) (A/ B/ SB) m3/ h m3/ h N mm mm mm Kg dBA dBA FVXS25F 8,2/ 4,8/ 4,1 8,8/ 5,0/ 4,4 5+A+S 600 700 210 14,0 38/ 26/ 23 38/ 26/ 23 FVXS35F 8,5/ 4,9/ 4,5 9,4/ 5,2/ 4,7 5+A+S 600 700 210 14,0 39/ 27/ 24 39/ 29/ 26 FVXS50F 10,7/ 7,8/ 6,6 11,8/ 8,5/ 7,1 5+A+S 600 700 210 14,0 44/ 36/ 33 45/ 36/ 33

Weight Sound pressure

Unidades exteriores
External units Compressor units Refrigerant Dimensions RXS25G SWING R-410 A 550 765 285 34,0 46/ 43 47/ 44 10 20 RXS35G SWING R-410 A 550 765 285 34,0 48/ 44 48/ 45 10 20 RXS50G SWING R-410 A 735 825 300 48,0 48/ 44 48/ 45 10 20

High Wide Background Cooling Heating (A/ B) (A/ B)

Weight Sound pressure Refrigerant load Additional load

mm mm mm Kg dBA dBA m gr/ m

Note: 1 .- Energy Efficiency Label: from A (most efficient) to G (least efficient) 2 .- Annual energy consumption: based on an average usage for 500 hours of operation per year at full load (= nominal conditions) Note: capacities are based on the following conditions: 1 .- Cooling: indoor temperature 27 CBS, CBH 19th, outdoor temperature 35 CBS 2 .- Heating: indoor temperature 20 CBS, CBS outdoor temperature 7 , 6 CBH. 3 .- refrigerant piping length: 7.5 m, power: 220/1/50 measurement noise is carried out in an anechoic chamber at a distance of 1 meter from the unit.

VXS25F Maximum pipe length Maximum level difference m m 20 15

VXS35F 20 15

VXS50F 30 20

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Heat pump
Soil-ceiling units Inverter/ Split

Photocatalytic deodorising filter It is a bactericidal and deodorizing filter that quickly neutralizes the smell of snuff and animals and also reduces the reproduction of bacterium and micro-organisms trapped in the filter. If the effectiveness of the filter decreases, can be restored by exposing it to sunlight. Filter air purifier The air filter traps particles down to 0.01 microns to purify the air of a room. The filter has a double-sided electrostatic filter cleaning air into the front side and a deodorizing activated charcoal filter in the rear.

Plus: o Can be installed on the ceiling or the bottom of the walls. o extremely quiet operation inside up to 28 dB (A) and abroad. The "silent mode" reduces the noise level of the indoor unit and / or external 3 dB (A). o The automatic routing of the air ensures a uniform distribution of temperature. o The "night mode" automatically reduces the sound level of the outdoor unit by 3 dB (A). o drain tray can be placed vertically or horizontally.
LXS-B series TLXS25B FLXS25B+RXS25G= 925,00+587,00 TLXS35B FLXS35B+RXS35G= 1.058,00+679,00 TLXS50B FLXS50B+RXS50G= 1.736,00+1.156,00 / Unit 1.512,00 1.707,00 1.892,00
www.alvarezhortas.es

PAM inverter technology The inverter technology PAM (pulse amplitude modulation) allows a better performance in cooling and heating and reduced energy consumption. With a minimum consumption is obtained with maximum comfort.

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

Air Aconditioning, Catalog - Tariff

Soil-ceiling split, set


Soil-ceiling set Capacity Cooling Heating Consumption Conexions Voltage N wires interconnecting EER COP Labeting energy efficiency Annual energy consumption Cooling heating Liuid Gas Min-Nom-Max Min-Nom-Max Mjn-Nom-Max Min-Nom-Max W Kcal/h W Kcal/h W W mm mm LXS25B 1.200-2.500-3.000 1.032-2.150-2.580 1.200-3.400-4.500 1.032-2.924-3.870 300-650-860 290-980-1.490 6,4 (1/ 4) 9,5 (3/ 8) I/ 220V 3+T 3,85 3,47 A B 325 LXS35B 1.200-3.500-3.800 1.032-3.010-3.268 1.200-4.000-5.000 1.032-3.440-4.300 300-1.130-1.260 290-1.230-1.850 6,4 (1/ 4) 9,5 (3/ 8) I/ 220V 3+T 3,10 3,25 B C 565 LXS50B 900-4.900-5.300 774-4.214-4.558 900-6.100-7.500 774-5.246-6.450 450-1.720-1.950 310-1.820-3.540 6,4 (1/ 4) 9,5 (3/ 8) I/ 220V 3+T 2,85 3,35 C C 860

Cooling Heating Cooling Heating Cooling

kWh

Soil-ceiling internal units


Internal units, soil-ceiling Air flow Speed fan Dimensions Cooling Heating high wide background Cooling Heating (A/ B/ SB) (A/ B/ SB) (A/ B/ SB) (A/ B/ SB) m3/ h m3/ h N mm mm mm Kg dBA dBA FLXS25B 7,6/ 6,0/ 5,2 9,2/ 7,4/ 6,6 5+A+S 490 1.050 200 16,0 37/ 31/ 28 37/ 31/ 29 FLXS35B 8,6/ 6,6/ 5,6 9,8/ 8,0/ 7,2 5+A+S 490 1.050 200 16,0 38/ 32/ 29 39/ 33/ 30 FLXS50B 11,4/ 8,5/ 7,6 12,1/ 7,5/ 6,8 5+A+S 490 1.050 200 17,0 47/ 39/ 36 46/ 35/ 33

Weight Sound pressure

External units
External units Compressor type Refrigerant Dimensions RXS25G SWING R-410 A 550 765 285 30,0 46/ 43 47/ 44 10 20 RXS35G SWING R-410 A 550 765 285 32,0 48/ 44 48/ 45 10 20 RXS50G SWING R-410 A 735 825 300 49,0 48/ 44 48/ 45 10 20

High Wide Background Cooling Heating (A/ B) (A/ B)

Weight Sound pressure Refrigerant load Additional load

mm mm mm Kg dBA dBA m gr/ m

Note: 1 .- Energy Efficiency Label: from A (most efficient) to G (least efficient) 2 .- Annual energy consumption: based on an average usage for 500 hours of operation per year at full load (= nominal conditions)

Note: capacities are based on the following conditions: 1 .- Cooling: indoor temperature 27 CBS, CBH 19th, outdoor temperature 35 CBS 2 .- Heating: indoor temperature 20 CBS, CBS outdoor temperature 7 , 6 CBH. 3 .- refrigerant piping length: 7.5 m, power: 220/1/50 measurement noise is carried out in an anechoic chamber at a distance of 1 meter from the unit.

LXS25B Maximum pipe length Maximum level difference m m 20 15

LXS35B 20 15

LXS50B 30 20

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Heat pump
Multi-Inverter units Inverter/ Multiple

Compatible internal units Wall unit FTXS-DW/ CTXS-DW Wall unit FTXS50-60-71B Soil unit FVXS-B Soil-Ceiling unit FLXS-B Ducts unit F(D)BQ-B Ducts unit FDXS/ CDXS-C Cassette 600x600 unit FFQ-B Ceiling horizontal unit FHQ-B

2x1 2MXS40D 20-25-35 25-35 25-35 -

3x1 3MXS52D 20-25-35-50 50 25-35-50 25-35-50 25-35-50 25-35-50 25-35-50 35-50

4x1 4MXS68D 20-25-35-50 50-60 25-35-50 25-35-50 25-35-50-60 25-35-50-60 25-35-50-60 35-50-60

4x1 4MXS80D 20-25-35-50 50-60-71 25-35-50 25-35-50 25-35-50-60 25-35-50-60 25-35-50-60 35-50-60

5x1 5MXS90E 20-25-35-FTKS50DW 50-60-71 (serie E) 25-35-50 25-35-50 25-35-50-60 25-35-50-60 25-35-50-60 25-35-50-60

Note: 1 .- Energy Efficiency Label: from A (most efficient) to G (least efficient). 2 .- Annual energy consumption: based on an average use of 500 hours of operation per year at full load (= nominal conditions). Note: capacities are based on the following conditions: 1 .- Cooling: indoor temperature 27 CBS, 19th CBJH, outside temperature 35 CBS. 2 .- Celafaccin: indoor temperature 20 CBS, CBS outdoor temperature 7 , 6 CBH. 3 .- refrigerant piping length: 7.5 m, power: 220/1/50. measurement noise is carried out in an anechoic chamber at a distance of 1 meter from the unit.

Multi - Inverter external units


Multiple external units Capacity Consumption Compressor type Refrigerante Pipes conexions Cooling. Heating. Cooling. Heating. Min-Nom-Max Min-Nom-Max Min-Nom-Max Min-Nom-Max W Kcal/ h W Kcal/ h 2x1 2MXS40G 1.500-3.900-4.200 1.500-4.400-4.700 400-1.240-1.520 340-1.220-1.450 SWING R-410 A 6,4x2 9,5x2 640 685 285 39,0 47/ 43 48/ 44 I/ 220V 3+T 20 20 25+35 3,42 3,61 A A 620 1.252,00 3x1 3MXS52G 1.490-5.200-6.500 2.300-6.800-7.340 360-1.710-2.420 490-1.680-1.890 SWING R-410 A 6,4x3 9,5x2, 12,7x1 735 936 300 55,0 46/ 43 47/ 44 I/ 220V 3+T 30 20 1.681,00 4x1 4MXS68F 2.420-6.800-8.670 3.040-8.600-10.640 510-2.060-3.270 680-2.060-2.620 SWING R-410 A 6,4x4 9,5x2, 12,7x2 735 936 300 59,0 48/ 43 49/ 44 I/ 220V 3+T 30 20 2.862,00 4x1 4MXS80E 2.740-8.000-9.340 3.570-9.600-10.880 530-2.180-2.820 810-2.270-2.750 SWING R-410 A 6,4x4 9,5x2, 12,7x1, 15,9x1 908 900 320 73,0 48/ 43 49/ 44 I/ 220V 3+T 40 20 3.458,00 5x1 5MXS90E 3.700-9.000-10.500 5.500-10.300-11.500 685-2.466-3.200 1.170-2.341-3.043 SWING R-410 A 6,4x5 9,5x2, 12,7x1, 15,9x1 770 900 320 69,0 52/ 47 52/ 48 I/ 220V 3+T 35 20 4.220,00

Liquid Gas

mm mm mm mm mm kg dB(A) dB(A)

Dimensions

High Wide Background

Weight Cooling. Heating. Voltage N wires interconnecting Refrigerant load Adicional load Wall units combination FTKS-DW EER Cooling. COP Heating. Cooling. Labeting energy effciency Heating. Annual energy Cooling. consumption / Unit Sound pressure level (A/ B)

m gr/ m

kW/h

Mltiple external units Length mx. de tubera (L1 + L2 + ...) Level difference mx. (H) Length mx. for internal units (L1, L2,...) Level difference between units (h) m m m m

2MXS40D 30 15 20 7,5

3MXS52D 45 15 25 7,5

4MXS68D 60 15 25 7,5

4MXS80D 70 15 25 7,5

5MXS90E 75 15 25 7,5

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Multiple external units

Heat pump
Super Multi-Inverter Units
RMXS112D RMXS140D 14.000 12.040 16.000 13.760 5.220 5.320 2,68 3,01 8 (3) I/ 220V SCROLL 2 9,5 (3/8) 19,1 (3/4) 104 107 1.345 900 320 127,0 51/ 53 6,238,00 RMXS160D 15.500 13.330 17.500 15.050 5.560 5.560 2,79 3,15 9 (3) I/ 220V SCROLL 2 9,5 (3/8) 19,1 (3/4) 104 109 1.345 900 320 127,0 51/ 53 7.239,00 W Kcal/ h W Kcal/ h W W 11.200 9.632 12.500 10.750 3.570 4.020 3,14 3,11 B D 1.785 6 (3) I/ 220V SCROLL 2 9,5 (3/8) 19,1 (3/4) 104 107 1.345 900 320 127,0 51/ 53 5.944,00

Nominal capacity

cooling Heating

Nominal consumption EER COP Energy label Annual energy consumption Internal units connection (mx) Voltage Compressor type N Inter. Connection Pipes connection Air flow Dimensions

Cooling Heating Cooling Heating Cooling Heating Cooling (n boxes BP)

Note: 1 .- Energy Efficiency Label: from A (most efficient) to G (least efficient). 2 .- Annual energy consumption: based on an average use of 500 hours of operation per year at full load (= nominal conditions). Note: capacities are based on the following conditions: 1 .- Cooling: indoor temperature 27 CBS, 19th CBJH, outside temperature 35 CBS. 2 .- Celafaccin: indoor temperature 20 CBS, CBS outdoor temperature 7 , 6 CBH. 3 .- refrigerant piping length: 7.5 m, power: 220/1/50. measurement noise is carried out in an anechoic chamber at a distance of 1 meter from the unit.

kW/ h n

Liquid Gas Cooling Heating Alto Ancho Fondo Cold./ Heat.

mm mm m3/ min m3/ min

Weight Sound pressure level Prices

dBA

Centralized controls Prices

DCS302B51 1.801,00

DCS301B51 899,00

DST301B51 899,00

DCS601C51 3.425,00

How to calculate the additional amount of refrigerant should be added: Additional amount of refrigerant should be added R (kg). The value of R must be rounded in units of 0.2 kg.

conection cards centralized controls KRP928A2S DTA112B51 Distribution boxes N internal units Price Price Price BPMKS976A2 2 230,00

FTXS/ CTXS, FVXS, FLXS, FDXS, CDXS 367,00 BPMKS967A3 3 290,00

F(D) BQ, FFQ, FHQ 206,00

Example for the calculation of aditional load


For combine with borad Refnet Price KHRQ22M20T 91,00
L1: 6,4x4 m L2: 6,4x5 m L3: 6,4x7 m L4: 6,4x4 m L5: 6,4x6 m L7: 6,4x4 m L7: 6,4x6 m A: 9,5x7 m B: 9,5x4 m c: 9,5x2 m

Super Multi Inverter with R-410 A o Multiple high-capacity system, combining up to 9 units with independent control and with a single outdoor unit. o Many possible combinations, a variety of designs and capacities to du to different needs. o Power I / 200V (single phase) greatly simplifies the wiring.

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Heat pump
Super Multi-Inverter units

o Maximum length of 115 meters and pipes up to 30 meters, allowing great comfort in the facility. o Only two pipes (liquid and gas) connecting the outdoor unit with boxes of Distribution. o Single Power Supply.

RMXS112D Maximum pipe length Total system (1) Box internal unit (2) Maximum height difference Box internal unit (1 room) External unit box/ internal unit Box box, internal unit internal m m m m m 115 60 15 30 15

RMXS140D

RMXS160D

135 80 15 30 15

145 90 15 30 15

(1): total length of pipe (m). for example, a 7x1 assembly, as shown in diagram 1, it = A + B + C + L1 + L2 + L3 + L4 + L5 + L6 + L7. (2): Length of pipe between cash - unid. Internal (m). for example in a 7x1 mount, as shown in diagram 1, it = L1 + L2 + L3 + L4 + L5 + L6 + L7.

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Heat pump
ALTHERMA System of simultaneous cooling and domestic hot water
Altherma is a system of simultaneous cooling and domestic hot water. This revolutionary system extracts the free energy of the outside air to heat the home to a comfortable temperature in both the coldest days of winter or summer. Altherma can connect to both a low temperature radiator heating elements for heating and is ideal for combination with production of hot water through solar energy panels. Additionally, you can save up to 50% of energy through technology Inverter. With this new system, Daikin leading solutions in the growing market for advanced low temperature heating.

Features: 1. It is possible to use different types of housing is compatible with: - Fan Coils apartment type ducts. - System Fan Coils individualized for each room. - Fan Coils and heating, offering a solution with the same system for different applications. - Heaters at low temperature (55 C). 2. Altherma can be specified in new construction in reform projects.

Plus: 1. High performance (COP) Seasonal: above 4.5 according to use. 2. Very low noise levels. 3. Minimizes operating costs. 4. The unit can provide water cooled to 7 C for use through fan coils. 5. The hot water can benefit from the efficiency of the heat pump and hot water at 55 C. 6. Compatible with solar energy (solar panels).

ALTHERMA WF006BR3 ERHQ006BV3+EKHBX008BBV3+EKHSWS150B3V3+EKHBDP= 1.636,00+2.077,00+1.267,00+260,00 WF007BR3 ERHQ007BV3+EKHBX008BBV3+EKHSWS150B3V3+EKHBDP= 1.963,00+2.077,00+1.267,00+260,00 WF008BR3 ERHQ008BV3+EKHBX008BBV3+EKHSWS200B3V3+EKHBDP= 2.208,00+2.077,00+1.304,00+260,00 WF011BR3 ERHQ011BV3+EKHBX006BBV3+EKHSWS200B3V3+EKHBDP= 3.084,00+2.504,00+1.304,00+260,00 WF014BR3 ERHQ014BV3+EKHBX016BBV3+EKHSWS300B3V3+EKHBDP= 3.701,00+2.504,00+1.477,00+260,00 WF016BR3 ERHQ016BV3+EKHBX016AB3V3+EKHSWS300B3V3+EKHBDP= 4.441,00+2.504,00+1.477,00+260,00

/ Unit

5.240,00 5.567,00 5.849,00 7.152,00 7.942,00 8.682,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

ERYQAC/ ERHQ, external units


ERYQAC/ ERHQ external units Capacity Dimensions Refrigerant Sound pressure Cooling Heating High wide background kW kW mm mm mm dB(A) ERYQ005AC 5,12 5,75 797 960 390 R-410 A 48 ERYQ006C 5,86 6,84 797 960 390 R-410 A 48 ERYQ007AC 6,08 8,43 797 960 390 R-410 A 52 ERHQ011A 10,00 11,20 11,70 900 320 R-410 A 42 ERHQ014A 12,50 14,00 1.170 900 320 R-410 A 42 ERHQ016A 13,10 16,00 1.170 900 320 R-410 A 43

HidroKits EKHB007/ EKHBX016


Hidrokits EKHBX007/ EKHBX016 Combination Dimensions Sound pressure High wide background mm mm mm dB(A) EJHB007AC3V3 ERYQ005AC 936 487 461 27 EJHB007AC3V3 ERYQ006AC 936 487 461 27 EJHB007AC3V3 ERYQ007AC 936 487 461 27 EJHB016AAC3V3 ERYQ011AAV3 939 502 361 30 EJHB016AAC3V3 ERYQ014AAV3 939 502 361 30 EJHB016AAC3V3 ERYQ016AAV3 939 502 361 30

DCW deposit acumulator


Storage cylinder HDW Volume Diameter High Weight l mm mm kg EKSWW150V3 150 500 850 37,00 EKSWW200V3 200 580 1.150 45,00 EKSWW300V3 300 580 1.600 59,00

Resistance available to support deposit of ACS 3 kW standard (no more power optional)

1. This new system allows simultneamnete: - Air conditioning cold / heat. - Hot water sanitary. 2. Easy and flexible. You do not need chimneys, fuel tanks or gas connections.

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

SkiAir range

Com or t I nver t er f
Ducts units Heat pump Inverter/ Split

All models include FBQ drainage pump series.

Plus: 1. Aspiration or lower back. 2. Outside air intake pre. 3. It adapts easily. 4. Unit extremely quiet at home and abroad. 5. Highly durable, washable filter.
Inverter BQ35C FBQ35C+RXS35G+BRC1D52= 787,00 + 679,00 + 80,00 BQ50C FBQ50C+RXS50G+BRC1D52= 828,00 + 1.156,00 + 80,00 BQ60C FBQ60C+RXS60F+BRC1D52= 979,00 + 1.228,00 + 80,00 BQ71C FBQ71C+RXS71D+BRC1D52= 1.138,00 + 1.617,00 + 80,00 BQ100C FBQ100C+RXS100D+BRC1D52= 1.378,00 + 2.144,00 + 80,00 BQ125C FBQ125C+RXS125D+BRC1D52= 1.477,00 + 2.280,00 + 80,00 BQ140C FBQ140C+RXS140D+BRC1D52= 2.008,00 + 2.983,00 + 80,00 / Unit

1.546,00 2.064,00 2.287,00 2.835,00 3.602,00 3.837,00 5.071,00

Optionals Decorative panels FBQ35-50 FBQ60-71 FBQ100-125 FBQ140

/ Unit BY BS45 BY BS71 BY BS125 BY BS125 254,00 295,00 348,00 348,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff


Ducts units
Ducts set Capacity Cold Heat Consumption connections Voltage N Inter. connection EER/ COP Energetic label Annual energy consumption Cold Heat Lquid Gas Min-Nom-Max Min-Nom-Max Min-Nom-Max Min-Nom-Max W Kcal/h W Kcal/h W W mm mm Inverter BQ35B 1.400-3.500-3.800 1.204-3.010-3.268 1.400-4.200-5.000 1.204-3.612-4.300 290-1.150-1.435 300-1.300-1.520 6,4 (1/4) 9,5 (3/8) I/ 220V 3+T 3,04/3,23 B/C 575 Inverter BQ50B 1700-5.000-5.300 1.462-4.300-4.550 1.700-5.800-6.000 1.462-4.988-5.160 390-1.550-1.750 425-1.750-2.250 6,4 (1/4) 12,7 (1/ 2) I/ 220V 3+T 3,22/3,31 A/C 775 Inverter BQ60B 1.700-6.000-6.500 1.462-5.160-5.590 1.700-7.000-8.000 1.462-6.020-6.880 440-1.190-2.300 400-2.040-2.180 6,4 (1/4) 12,7 (1/ 2) I/ 220V 3+T 3,01/2,90 B/C 995 BQ71B 7.100 6.106 8.000 6.880 2.500 2.350 9,5 (3/8) 15,9 (5/ 8) I/ 220V 3+T 2,84/3,40 C/C 1.250

Cold/Heat Cold/Heat Cold

kWh

BQ100B 10.000 8.600 11.200 9.632 3.750 3.400 9,5 (3/8) 15,9 (5/ 8) I/ 220V 3+T 2,66/3,29 C/C 1.875

BQ125B 12.500 10.750 14.000 12.040 4.400 4.240 9,5 (3/8) 15,9 (5/ 8) III/ 380V 3+T 2,84/3,30 C/C 2.200

Ducts internal units


Ducts internal units Air flow Cold Heat Standard/High High Wide background Cold. Heat Modelo (A/ B) (A/ B) (A/ B) (A/ B) m3/ min m3/ min mmH2O N mm mm mm kg dBA dBA FBQ35B 11,5/ 9 11,5/ 9 5/ 9 2 300 700 800 30,0 33/ 29 33/ 29 BYBS45 FBQ50B 14/ 10 14/ 10 5/ 9 2 300 700 800 31,0 33/ 29 33/ 29 BYBS45 FBQ60B 19/ 14 19/ 14 5/ 9 2 300 1.000 800 41,0 34/ 30 34/ 30 BYBS71 FBQ71B 19/ 14 19/ 14 5/ 9 3 300 1.000 800 41,0 34/ 30 34/ 30 BYBS71 RBQ100B 27/ 20 27/ 20 5/ 9 3 300 1.400 800 51,0 36/ 31 36/ 31 BYBS125 FBQ125B 35/ 24 35/ 24 5/ 9 3 300 1.400 800 52,0 38/ 21 38/ 21 BYBS125

Fans speeds dimensions

Weight Sound pressure Panel decorativo

External units
External units Air flow Comprensser type Refrigerant Dimensions Cold Heat (A/ B) (A/ B) m3/ min m3/ min RKS35G 33,5/ 23,4 30,2/ 28,3 SWING R-410 A 550 765 285 34,0 48/ 44 48/ 45 10 20 RKS50G 48,9/ 45,0/ SWING R-410 A 735 825 300 49,0 48/ 44 48/ 45 10 20 RKS60F 50,9/ 46,3/ SWING R-410 A 735 825 300 48,0 49/ 46 49/46 RZQ71C 54,5/ 48,1/ SWING R-410 A 770 900 320 68,0 49/ * 51/* 10 20 RZQS100C 61,3/ * 61,7/* SWING R-410 A 770 900 320 68,0 51/ * 55/* RZQS125C 99/ * 100/* SWING R-410 A 1.170 900 320 100,0 51/ * 53/* Consult table

High Wide Background Cold Heat (A/ B) (A/ B)

Weight Sound pressure Refrigerant load for Additional load

mm mm mm kg dBA dBA m gr/ m

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Com or t I nver t er f
4 way Cassette 60x60 units Heat pump Inverter/ Split

Plus: o Aspiration lower. o frees up space on the roofs and walls to real estate, decoration and other accessories. o External air intake pre. o Adapts easily. o extremely quiet units at home and abroad. o Washable filter for high durability.

/ Unit FQ25B FFQ25B+RXS25G+BRC7E530W= 466,00 + 587,00 + 315,00 BQ35B FFQ35B+RXS35G+BRC7E530W= 552,00 + 679,00 + 315,00 BQ50B FFQ50B+RXS50G+BRC7E530W= 505,00 + 1.156,00 + 315,00 BQ60B FFQ60B+RXS60G+BRC7E530W= 812,00 + 1.228,00 + 315,00

1.533,00 1.711,00 2.141,00 2.520,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Cassette set
Cassette set Capacity Cold Heat consumption connections Voltage N Inter. connection EER/ COP Energetic label Annual energy consumption Cold Heat Lquid Gas Min-Nom-Max Min-Nom-Max Min-Nom-Max Min-Nom-Max W Kcal/ h W Kcal/ h W W mm mm Inverter FQ25B 1.300-2.500-3.000 1.118-2.150-2.580 1.300-3.200-4.500 1.118-2.752-3.870 290-800-1.000 270-900-1.650 6,4 ( 1/ 4) 9,5 ( 3/ 8) I/220V 3+T 3,12/ 3,55 B/ B 400 Inverter FQ35B 1.400-3.400-3.700 1.204-2.924-3.182 1.400-4.500-5.000 1.204-3.870-4.300 290-1.150-1.350 270-1.450-1.700 6,4 ( 1/ 4) 9,5 ( 3/ 8) I/220V 3+T 3,04/ 3,10 B/ D 575 Inverter FQ50B 900-4.700-5.600 774-4.042-4.816 900-5.500-7.000 774-4.730-6.020 350-1.550-1.700 400-1.700-2.100 6,4 ( 1/ 4) 12,7(1/2) I/220V 3+T 3,22/ 3,41 A/ B 775 Inverter FQ60B 900-5.800-6.000 774-4.988-5.160 900-7.000-8.000 774-6.020-6.880 440-1.990-2.300 400-2.040-2.810 6,4 ( 1/ 4) 12,7(1/2) I/220V 3+T 3,01/ 2,90 B/ C 995

Cold/ Heat. Cold/ Heat. Cold

kWh

Cassette internal units


Cassette internal units Air flow Fans speeds Dimensions Cold./ Heat. High Wide background Cold./ Heat. Model High Wide background (A/ B) (A/ B) m3/ N mm mm mm kg dBA mm mm mm kg min FFQ25B 9/ 6,5 2 286 575 575 17,5 29,5/ 24,5 BYFQ60B 55 700 700 2,7 FFQ35B 10/ 6,5 2 286 575 575 17,5 32/ 25 BYFQ60B 55 700 700 2,7 FFQ50B 12/ 8 2 286 575 575 17,5 36/ 27 BYFQ60B 55 700 700 2,7 FFQ60B 15/ 10 2 286 575 575 17,5 41/ 32 BYFQ60B 55 700 700 2,7

Weight Sound pressure Panel decorative Dimensions panel

Weight panel

External units
External unit Caudal del aire Tipo de compresor Refrigerante Dimensiones Cold Heat. (A/ B/ SB) (A/ B/ SB) m3/ min m3/ min RXS25G 36,2/ 25,7 32,6/ 30,6 SCROLL R-410 A 550 765 285 30,0 46/ 43 47/ 44 10 20 RXS35G 33,5/ 23,4 30,2/ 28,3 SCROLL R-410 A 550 765 285 32,0 47/ 44 48/ 45 10 20 RXS50G 48,9/ * 45,0/ * SCROLL R-410 A 735 825 300 49,0 48/ 44 48/ 45 10 20 RXS60F 50,9/ * 46,3/ * SCROLL R-410 A 735 825 300 53,0 49/ 46 49/ 46 10 20
Inverter FQ25B Maximum pipe length (L) Maximumlevel difference (H) m m 20 15 Inverter FQ35B 20 15 Inverter FQ50B 30 20 Inverter FQ60B 30 20

High Wide background Cold Heat. (A/ B) (A/ B)

Peso Presin sonora Carga de refrigerante para Carga adicional

mm mm mm kg dBA dBA m gr/ m

Note: 1 .- Energy Efficiency Label: from A (most efficient to G (least efficient). 2 .- Annual energy consumption: based on an average use of 500 hours of operation per year at full load (= nominal conditions) Note: The capabilities are based on the following conditions: 1 .- Cooling: indoor temperature 27 CBS, CBH 19th, outdoor temperature 35 CBS. 2 .- Heating: indoor temperature 20 CBS, CBS outdoor temperature 7 , 6 CBH. 3 .- refrigerant piping length: 7.5 m, 220/1/50 power. The sound level measurement is performed in an anechoic chamber at a distance of 1 meter from the unit.

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Com or t I nver t er f
Round Flow cassette unit Heat pump Inverter/ Split
New Round Flow The new unit rounf flow cassette offers several improvements in various aspects such as user comfort, ease of installation and energy efficiency. The round flow cassette unit creates a high level of comfort as a result of: 1. Dsitribucion radial air 360 ' 2. Greater horizontal airflow that translates into fewer cold drafts. 3. The reduction of air speeds result in less direct exposure to cold drafts in occupied areas. The routes can be overridden with locking kits, which lets you install the unit in the center or the corner of a room or small room.

Uniform temperature: The discharge temperature of air from the corners avoids dead zones that can have significant changes in temperature.

Plus: 1. Maximum energy efficiency. Highest values of COP. 2. Minimum height 214mm installation very small. 3. Available in a variety of sizes. 4. Grid with a less visible and more attractive appearance. 5. It is very quiet when running, with noise levels of only 27 dB, a noise comparable to the whisper of the leaves. 6. Easy installation and maintenance thanks to the total weight of the unit. Minimum weight of only 19 kg.

/ Unit CQ35C FCQ35C+RXS35G+BYCQ140C+BRC7F532F= 580,00 + 679,00 + 393,00 + 165,00 CQ50C FCQ50C+RXS50G+BYCQ140C+BRC7F532F= 530,00 + 1.156,00 + 393,00 + 165,00 CQ60C FCQ60C+RXS60F+BYCQ140C+BRC7F532F= 852,00 + 1.228,00 + 393,00 + 165,00 CQ71C FCQ71C+RXS71D+BYCQ140C+BRC7F532F= 663,00 + 1.617,00 + 393,00 + 165,00

1.817,00 2.244,00 2.638,00 2.808,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Com or t I nver t er f
Ceiling horizontal units Heat pump Inverter/ Split

o Optimum air distribution. o It is the ideal solution for shops, restaurants or offices without false ceiling. o There are 2 ways to adjust the angle of discharge of air. 1.A. Direction up and down (automatic). 2.B. Left and right. o frees up space on the roofs and walls to furniture, decor and other accessories. o extremely quiet units at home and abroad. o measuring the temperature moves automatically between the sensor and the sensor back in command, achieving greater precision and more comfort. o Address auto air flow which guarantees a uniform distribution of temperaHQ35B ture and air flow. FCQ35B+RXS35G+BRC1D52 = 716,00 + 679,00 + 80,00 o The distribution of HQ50B the airflow can be FCQ50B+RXS50G+BRC1D52 = 795,00 + 1.156,00 + 80,00 adapted to suit ceiHQ60B ling heights up to FCQ60B+RXS60F+BRC1D52 = 878,00 + 1.228,00 + 80,00 HQ71B 3.8 m without loss of FCQ71B+RXS71C+BRC1D52 = 1.099,00 + 1.617,00 + 80,00 capacity.

/ Unit

1.475,00 2.031,00 2.186,00 2.796,00 3.540,00 3.782,00 165,00

HQ100B FCQ100B+RXS100C+BRC1D52 = 1.316,00 + 2.144,00 + 80,00 HQ125B FCQ125B+RXS125C+BRC1D52 = 1.442,00 + 2.280,00 + 80,00 Control remote without hose electric BRC7E63W

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Com or t I nver t er f
Confort Inverter wall units Heat pump Inverter/ Split

Units internal o Design which enables the most efficient use of land. o The size 71 is a lightweight and compact casing. o Uniform distribution of air moving through an automatic alert can be set at the desired angle. o When the unit is not running, the alert is closed. o The front panel of the casing (size 71) can be removed and washed easily. o Very quiet. Units External o The maximum length of pipe RZQS is set to 50 m, covering most standard applications. o Both the model 71 and 100 are equipped with a swing compressor. This eliminates the friction and leakage of refrigerants and improves power consumption. o Night quiet mode function: max -5 dB (A). o The maximum power consumption can be controlled easily using the I-demand. o Wide range of operation.

The remote cable provides a function that allows the operation of air conditioning daily or weekly.

/ Unit AQS71B FAQ71B + RZQS71C + BRC1D52 = 1.492,00 + 1.617,00 + 80,00 AQS100B FAQ100B + RZQS100C + BRC1D52 = 1.824,00 + 2.144,00 + 80,00 Control remot FAQ71B BEC7E618 without hoses BRC7C510W electric (optional) FAQ100B 3.189,00 4.048,00 165,00 165,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Super I nver t er
Super Inverter Ducts Heat pump Inverter/ Split

Function Plus:

reco-

very of refrigerant The refrigerant recovery function enables all expansion valves to open. Thus, the coolant can be drained from the piping system and stored in the receiver and the condenser.

o frees up space on the roofs and walls to furniture, decor and other accessories. o The inverter control can respond to differences in temperature of 0.5 C. o Mode "Low Level Sound Night." o If required, the Super Inverter outdoor unit can reduce the noise level up to 8 dBA. o You can set the mode for night operation, or automatically according to the schedule set by the user.

HANDLES Incorporates handgrips to facilitate transport and installation of equipment. I-demand function: A new flow sensor reduces the difference between the actual energy consumption and energy consumption default. You can control the maximum power consumption. Energy saving capacitors Swing and Scroll are operated with a new engine that offers increased performance and energy efficiency. 4 used neodymium magnets, stronger than the ferrite.

/ Unit ZBQ71C FBQ71C+RZQ71D+BRC1D52 = 1.138,00 + 2.123,00 + 80,00 ZBQ100C FBQ100C+RZQ100D+BRC1D52 = 1.378,00 + 2.940,00 + 80,00 ZBQ125C FBQ125C+RZQ125D+BRC1D52 = 1.477,00 + 3.280,00 + 80,00 ZBQ140C FBQ140C+RZQ140D+BRC1D52 = 2.008,00 + 3.825,00 + 80,00 Decorative panels FBQ71 FBQ100/125 FBQ140

3.341,00 4.398,00 4.837,00 5.913,00 295,00 348,00 348,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Sper inverter Round flow casette Heat pump Inverter/ Split


Plus: 1. Maximum energy efficiency. Highest values of COP. 2. Easy to handle. 3. Very lightly. 4. Conexion serial = DIII NET without the need for adapter PCB. 5. Ladder in a variety of sizes. 6. New panel with an attractive decorative finish "cool white" RAL 9010. 7. Grid with a less visible and more attractive appearance. 8. It is very quiet with noise levels of only 27 dB, a noise comparable to the whisper of the leaves. 9. Easy installation and maintenance thanks to the total weight of the unit. Minimum weight of only 19 kg. The new round flow cassette offers several improvements in various aspects such as user comfort, ease of instalacion and energy efficiency. Pattern of radial airflow 360 'creates an improved air distribution and uniform, which reduces the temperature difference between different points of the environment, while the larger air flow resulting in a horizontal reduccion from cold drafts and a minimum energy consumption. Represents a solution with a very low installation height for customers who need a compact unit for use in suspended ceilings. Flexible installation and easy to use FCQ-C series of fine structure is a solution with a very low installation height for customers who need a compact unit for use in suspended ceilings.

Super I nver t er

/ Unit ZCQ71C FCQ71C+RZQ71C+BYC140C+BRC7F532F= 633,00 + 2.123,00 + 393,00 + 165,00 ZCQ100C FCQ100C+RZQ100C+BYC140C+BRC7F532F= 659,00 + 2.940,00 + 393,00 + 165,00 ZCQ125C FCQ125C+RZQ125C+BYC140C+BRC7F532F= 1.085,00 + 3.280,00 + 393,00 + 165,00 ZCQ140C FCQ140C+RZQ140C+BYC140C+BRC7F532F= 1.338,00 + 3.825,00 + 393,00 + 165,00

3.341,00 4.157,00 4.923,00 5.721,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Sper Inverter Cassette Sight heat pump Inverter/ Split

Super I nver t er

Plus: o frees up space on the roofs and walls to furniture, decor and other accessories. o The inverter control can respond to differences in temperature of 0.5 C. o Mode "Low Level Sound Night." o If required, the Super Inverter outdoor unit can reduce the noise level up to 8 dBA. o You can set the mode for night operation, or automatically according to the schedule set by the user.

Function recovery Coolant The refrigerant recovery function enables all expansion valves to open. Thus, the coolant can be drained from the piping system and stored in the receiver and the condenser. HANDLES

Incorporates handgrips to facilitate transport and installation of equipment. I-demand function: A new flow sensor reduces the difference between the actual energy consumption and energy consumption default. You can control the maximum power consumption. Energy saving capacitors Swing and Scroll are operated with a new engine that offers increased performance and energy efficiency. 4 used neodymium magnets, stronger than the ferrite.

INVERTER ZUQ71B FUQ71B+RZQ71C+BRC7C528W= 1.158,00 + 2.123,00 + 165,00 ZUQ100B FUQ100B+RZQ100C+BRC7C528W= 1.429,00 + 2.940,00 + 165,00 ZUQ125B FUQ125B+RZQ125C+BRC7C528W= 1.606,00 + 3.280,00 + 165,00

/ Unit

3.446,00 4.534,00 5.051,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Sper Inverter Horizontal ceiling Heat pump Inverter/ Split


Plus: 1. Optimum air distribution. 2. It is the ideal solution for shops, restaurants or offices without false ceiling. 3. There are 2 ways to adjust the angle of discharge of air. - A. Direction up and down (automatic). - B. Left and right. 4. Frees up space on the roofs and walls to furniture, decor and other accessories. 5. Unit extremely quiet at home and abroad. 6. measuring the temperature moves automatically between the sensor and the sensor back in command, achieving greater precision and more comfort. 7. Automatic direction of the airflow that ensures a uniform distribution of temperature and air flow. 8. The form of distribution of the airflow can be adapted to suit ceiling heights up to 3.8 m without loss capacity.

Super I nver t er

/ Unit ZHQ71B FHQ71B+RZQ71C+BRC1D52= 1.099,00 + 2.123,00 + 80,00 ZHQ100B FHQ100B+RZQ100C+ BRC1D52= 1.316,00 + 2.940,00 + 80,00 ZHQ125B FHQ125B+RZQ125C+ BRC1D52= 1.422,00 + 3.280,00 + 80,00 Control remote without hose electric BRC7E63W

3.302,00 4.336,00 4.782,00

165,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Super I nver t er
super Inverter Wall units Heat pump Inverter/ Split
Units internal o The ideal solution for shops, restaurants and offices. o The design allows more efficient use of land. o The size 71 is a compact, lightweight casing. o Uniform distribution of air moving through an automatic alert can be set to the desired angle. o When the unit is not running, the alert is closed. o The front panel of the casing (size 71) can be removed and washed easily. o Very quiet. Units external oA compressor with inverter control to adjust the capacity to adapt to changes in the environment. o Equipped with an oscillating or rotary compressor, which is remarkable for its low noise and high efficiency. o The heat exchanger includes a galvanized finish with a special acrylic material as more advanced that ensures greater resistance to extreme climatic conditions.

/ Unit ZAQ71B ZAQ71B+RZQ71C+BRC1D52= 1.099,00 + 2.123,00 + 80,00 ZAQ100B ZAQ100B+RZQ100C+ BRC1D52= 1.316,00 + 2.940,00 + 80,00

3.695,00 4.844,00

Optionals / Unit Control remote with hose electric FAQ71B BRC7E618 165,00 FAQ100B BRC7C510W 165,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Gama Ski Air

High pressure ducts units Heat pump Inverter/ Split

Ski Ai r G eat r

Units External 1. High efficiency: - Increase the range of frequency control of the compressor. - Reduces time start / stop at low capacity. - Improved energy efficiency. 2. Possibility of operation in cooling mode only. 3. Wide range of operation. 4. Maximum pipe length: 100m (30m drop). 5. Silent Night mode feature. 6. Specially designed for units with combinations of high-capacity pipes or fittings twin, triple and double twin. Units internal 1. Compact unit with air filter lengthy series (models 200 and 250). 2. Maximum external static pressure (ESP) between 150 and 250 Pa. The new design of the grille and the blades of the fan allows the expulsion of air more quietly to avoid turbulence.
/ Unit DQ125B FDQ125B+RZQ125C+BRC1D52= 1.691,00 + 3.280,00 + 80,00 DQ200B FDQ200B+RZQ200C+BRC1D52= 2.154,00 + 6.119,00 + 80,00 DQ250B FDQ250B+RZQ250C+BRC1D52= 2.345,00 + 6.673,00 + 80,00

5.051,00 8.353,00 9.098,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Industriales range
Coolers inverter residential use EWA(Y)Q
Features 1. Power range: 5-7 kW. 2. Integration of all elements: With a compact chassis just 1.174x 737x 300 mm., Incorporating in it all the necessary components in an extremely compact system. The primary circuit is included in the team. 3. These small single coolers are designed specifically for HVAC applications in residential environments. They are ideal for installing the entire range of Daikin fan coil and systems in combination with underfloor heating. 4. The connection is made immediately, without need for major works, once the elements of the house. Hydronyms integrated module 5. Can be used to heat water for small outdoor pools and small industrial processes such as control of fermentation in small barrels of wine. 6. Installation is quick and easy, and requires only that the power supply. 7. Wide range of operation. Able to provide cold water with temperatures of 5 to 20 C or hot water with temperatures of 25 to 55 C with temperatures between -15 C and 46 C. 8. Gan compressor energy savings thanks to Swing Inverter. 9. Fins with standard anti-series. 10. Refrigerant R-410A.

M ni chi l l er i

COLD ONLY EWAQ005ACV3P EWAQ006ACV3P EWAQ007ACV3P HEAT PUMP EWYQ005ACV3P EWYQ006ACV3P EWYQ007ACV3P

/ Unit 3.715,00 4.020,00 4.264,00 3.959,00 4.264,00 4.507,00


www.alvarezhortas.es

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

Air Aconditioning, Catalog - Tariff

MINICHILLER

Cold only
MINICHILLER MinNomMax Nom EWAQ005AC3P EWAQ006ACV3P EWAQ007ACV3P Capacity Cooling Kw Kw 4,01-5,20-5,20 1,89 2,75 R-410A 805x1.190x360 100 SWING 62 48 I/ 220 V 10 mm 1 4,01-6,00-6,00 2,35 2,55 R-410A 805x1.190x360 100 SWING 62 48 I/ 220 V 10 1 4,01-7,10-7,10 2,95 2,41 R-410A 805x1.190x360 100 SWING 62 48 I/ 220 V 10 1

Consumption Cooling EER Refrigerant Dimensions (H-W-B) Weight compressor Sound power Cooling Sound Cooling pressure Voltage Water minium volume Water pipe Entry/output diameter

High High

mm Kg Kg dB(A) dB(A)

Heat pump
MINICHILLER Cooling Capacity Consumption Heating Cooling Heating MinNomMax Nom Kw Kw Kw Kw EWAQ005AC3P 4,01-5,20-5,20 4,09-5,65-6,83 1,89 1,97 2,75/2,87 R-410A 805x1.190x360 100 SWING 62 48 48 I/ 220 V 10 1 EWAQ006ACV3P 4,01-6,00-6,00 4,09-6,35-8,13 2,35 2,24 2,55/2,83 R-410A 805x1.190x360 100 SWING 62 48 48 I/ 220V 10 1 EWAQ007ACV3P 4,01-7,10-7,10 4,09-7,75-8,73 2,95 2,83 2,41/2,74 R-410 A 805x1.190x360 100 SWING 63 50 49 I/ 220 V 10 1

EER Refrigerant Dimensions (H-W-B) Weight compressor Sound power Cooling Sound Cooling pressure Heating Voltage Water minium volume Water pipe Entry/output diameter

High High

mm Kg Kg dB(A) dB(A) dB(A)

mm

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Fan Coi l s

o frees up space on the roofs and walls to furniture, decor and other accessories. o Adapts easily. o extremely quiet units.
F WV 4 tubes without valve (C FN) F WV01DF N 354 ,00 F WV02DF N 390 ,00 F WV03DF N 434 ,00 F WV04DF N 490 ,00 F WV06DF N 527 ,00 F WV08DF N 695 ,00 F WV10DF N 766 ,00 4 tubes with valve (CF V) F WV01DF V 751 ,00 F WV02DF V 787 ,00 F WV03DF V 831 ,00 F WV04DF V 903 ,00 F WV06DF V 940 ,00 F WV08DF V 1.12 5,00 F WV10DF V 1.19 7,00 2 tubes without valve (C TN) F WV01DT N 290 ,00 F WV02DT N 325 ,00 F WV03DT N 357 ,00 F WV04DT N 404 ,00 F WV06DT N 445 ,00 F WV08DT N 588 ,00 F WV10DT N 663 ,00 2 tubes with valve (CT V) F WV01DT V 488 ,00 F WV02DT V 524 ,00 F WD03 DTV 554 ,00 F WV04DT V 620 ,00 F WV06DT V 659 ,00 F WV08DT V 817 ,00 F WV10DT V 891 ,00 F WL 4 tubes without valve (C FN) F WL01D FN 3 72,00 F WL02D FN 4 04,00 F WL03D FN 4 55,00 F WL04D FN 5 13,00 F WL06D FN 5 54,00 F WL08D FN 7 37,00 F WL10D FN 8 17,00 4 tubes with valve (CF V) F WL01D FV 7 66,00 F WL02D FV 8 01,00 F WL03D FV 8 49,00 F WL04D FV 9 24,00 F WL06D FV 9 69,00 F WL08D FV 1 .166,00 F WL10D FV 1 .245,00 2 tubes without valve (C TN) F WL01D TN 3 03,00 F WL02D TN 3 38,00 F WL03D TN 3 78,00 F WL04D TN 4 26,00 F WL06D TN 4 71,00 F WL08D TN 6 31,00 F WL10D TN 7 11,00 2 tubes with valve (CT V) F WL01D TV 5 01,00 F WL02D TV 5 38,00 F WL03D TV 5 77,00 F WL04D TV 6 42,00 F WL06D TV 6 84,00 F WL08D TV 8 57,00 F WL10D TV 9 37,00 F WM 4 tubes without valve (C FN ) F WM01 DF N 296,00 F WM02 DF N 321,00 F WM03 DF N 361,00 F WM04 DF N 407,00 F WM06 DF N 437,00 F WM08 DF N 575,00 F WM10 DF N 635,00 4 tubes with valve (CF V) F WM01 DF V 693,00 F WM02 DF V 718,00 F WM03 DF V 758,00 F WM04 DF V 820,00 F WM06 DF V 849,00 F WM08 DF V 1.006,0 0 F WM10 DF V 1.065,0 0 2 tubes without valve (C TN ) F WM01 DT N 232,00 F WM02 DT N 253,00 F WM03 DT N 285,00 F WM04 DT N 325,00 F WM06 DT N 352,00 F WM08 DT N 468,00 F WM10 DT N 527,00 2 tubes with valve (CT V) F WM01 DT V 431,00 F WM02 DT V 450,00 F WM03 DT V 484,00 F WM04 DT V 540,00 F WM06 DT V 567,00 F WM08 DT V 695,00 F WM10 DT V 758,00 FWD 4 tubes (valve optional) (AF) FWD 04AF 620,00 FWD 06AF 785,00 FWD 08AF 916,00 FWD 10AF 1.033,00 FWD 12AF 1.397,00 FWD 16AF 1.637,00 FWD 18AF 1.804,00 2 tubes (valve optional) (AT) FWD 04AT 537,00 FWD 06AT 671,00 FWD 08AT 793,00 FWD 10AT 913,00 FWD 12AT 1.192,00 FWD 16AT 1.388,00 FWD 18AT 1.570,00 F WB 2 tube s (valve optional) (AT ) FW B0 2BTN 406,00 FW B0 3BTN 427,00 FW D04BTN 460,00 FW D05BTN 554,00 FW D06BTN 583,00 FW D07BTN 626,00 FW D08BTN 759,00 FW D09BTN 788,00 FW D10BTN 846,00 2 tube s w ith valve (AT V) FW B0 2BTV 554,00 FW B0 3BTV 574,00 FW B0 4BTV 606,00 FW B0 5BTV 704,00 FW B0 6BTV 733,00 FW B0 7BTV 776,00 FW B0 8BTV 908,00 FW B0 9BTV 936,00 FW B1 0BTV 995,00 Additio nal b atery for inst allation 4 tube s F WB FW B0 2/03/04 140,00 FW B0 5/06/07 157,00 FW B0 8/09/10 185,00

lvarez hortas C/ Francisco Aritio, 76 19004 Guadalajara (Spain)

www.alvarezhortas.es

Air Aconditioning, Catalog - Tariff

Soil units with bounding


Soil unit with bounding Cooling capacity ( tubes) (A) Total Sensitive Heating kw kW kW W 3 m/h mm Kg dBA FWV01 1,54 1,20 2,14 36 319/ 178 564/ 774/ 226 19,1 47/ 34 FWV02 2,09 1,51 2,79 46 344/ 211 564/ 774/ 226 20,1 52/ 36 FWV03 2,93 2,11 3,81 62 442/ 241 564/ 984/ 226 24,8 50/ 38 FWV04 4,33 3,15 5,63 87 706/ 361 564/ 1.194/ 226 30,4 55/ 40 FWV06 4,77 3,65 6,36 89 785/ 470 564/ 1.194/ 226 30,9 59/ 44 FWV08 6,71 4,91 7,83 182 1.011/ 570 564/ 1.404/ 251 41,3 59/ 44 FWV10 8,71 6,38 11,1 244 1.393/ 642 564/ 1.404/ 251 41,3 66/ 48

Total consumption (A) Air flow (A/ B) Dimensions Weight Sound power level (A/ B)

(AlxAnxF)

Soil-ceiling units with bounding


Floor/roof unit with bounding Cooling capacity ( tubes) (A) Total Sensitive Heating kw kW kW W 3 m/h mm kg dBA FWL01 1,54 1,20 2,14 36 319/ 178 246/ 774/ 564 20,1 47/ 34 FWL02 2,09 1,51 2,79 46 344/ 211 246/ 774/ 564 21,1 52/ 36 FWL03 2,93 2,11 3,81 62 442/ 241 246/ 984/ 564 26,8 50/ 38 FWL04 4,33 3,15 5,63 87 706/ 361 246/ 1.194/ 564 32,4 55/ 40 FWL06 4,77 3,65 6,36 89 785/ 470 246/ 1.194/ 564 32,9 59/ 44 FWL08 6,71 4,91 7,83 182 1.011/ 570 271/ 1.404/ 564 43,75 59/ 44 FWL10 8,71 6,38 11,1 244 1.393/ 642 271/ 1.404/ 564 43,75 66/ 48

Total consumption (A) Air flow (A/ B) Dimensions Weight Sound power level (A/ B)

(AlxAnxF)

Soil-ceiling without bounding


Floor/roof unit without bounding Cooling capacity ( tubes) (A) Total Sensitive Heating kw kW kW W m3/ h mm kg dBA FWM01 1,54 1,20 2,14 36 319/ 178 224/ 584/ 535 14,1 47/ 34 FWM02 2,09 1,51 2,79 46 344/ 211 224/ 584/ 535 15,1 52/ 36 FWM03 2,93 2,11 3,81 62 442/ 241 224/ 794/ 535 18,8 50/ 38 FWM04 4,33 3,15 5,63 87 706/ 361 224/ 1.004/ 535 22,9 55/ 40 FWM06 4,77 3,65 6,36 89 785/ 470 224/ 1.004/ 535 23,4 59/ 44 FWM08 6,71 4,91 7,83 182 1.011/ 570 249/ 1.214/ 535 31,75 59/ 44 FWM10 8,71 6,38 11,1 244 1.393/ 642 249/ 1.214/ 535 31,75 66/ 48

Total consumption (A) Air flow (A/ B) Dimensions Weight Sound power level (A/ B)

(AlxAnxF)

ceiliong units without bounding with available pressure (apartament type)


Soil unit without bounding with available pressure (apartament type) Cooling capacity ( tubes) (A) Total Sensitive Heating kw kW kW W Pa m3/ h mm kg dBA FWD01 3,90 3,08 4,05 177 90 800 280/ 754/ 558 32,5 66/ 58 FWD02 6,20 4,65 7,71 274 88 1.250 280/ 964/ 558 40,6 69/ 60,3 FWD03 7,80 6,52 9,43 315 100 1.600 280/ 1.174/ 558 47,3 72/ 64 FWD04 8,82 7,16 10,79 325 95 1.600 280/ 1.174/ 558 48,7 72/ 64 FWD06 11,90 9,36 14,45 530 130 2.200 353/ 1.174/ 718 65,3 74/ 65,7 FWD08 16,40 12,8 19,81 991 205 3.000 353/ 1.384/ 718 77 78/ 69,4 FWD10 18,30 14,10 21,92 1.001 185 3.000 353/ 1.384/ 718 79,5 78/ 69,4

Total consumption (A) Air flow (A/ B) Dimensions Weight Sound power level (A/ B) Cooling capacity ( tubes) (A)

(AlxAnxF)

Ceiling units without bounding with avaliable pressure


Soil unit without bounding with available pressure Cooling capacity ( tubes) (A) Total Sensitive Heating kw kW kW W Pa m3/ h mm kg dBA FWB01AT 2,61 1,88 5,47 106 71 400/ 180 239x1.039x609 24,0 46,5/ 24,5 FWB02AT 3,14 2,16 6,01 106 71 400/ 180 239x1.039x609 26,0 46,5/ 24,5 FWB03AT 3,49 2,34 6,47 106 71 400/ 180 239x1.039x609 28,0 46,5/ 24,5 FWB04AT 5,08 3,6 10,31 192 65 800/ 300 239x1.389x609 33,0 48,5/ 25,5 FWB06AT 5,45 3,87 11,39 192 65 800/ 300 239x1.389x609 35,0 48,5/ 25,5 FWB07AT 6,47 4,4 12,28 192 65 800/ 300 239x1.389x609 38,0 48,5/ 25,5

Total consumption (A) Air flow (A/ B) Dimensions Weight Sound power level (A/ B) Cooling capacity ( tubes) (A)

(AlxAnxF)

FWB08AT Conditions for the calculation of capacities: 1 .- Cooling: indoor temperature: 19.5 CBH; Water Temperature Input / Output: 7 C / 12 C. 2 .- Heating: indoor temperature: 20 CBS; inlet water temperature: 60 CBS. 7,57 5,23 15,05 294 59 1200/ 600 239x1.739x609 45,0 57,5/ 41,5

FWB09AT 8,67 5,96 16,85 294 59 1200/ 600 239x1.739x609 48,0 57,5/ 41,5

FWB10AT 10,34 6,9 18,78 294 59 1200/ 600 239x1.739x609 52,0 57,5/ 41,5