2-Multi-band Panel Dual Polarization Half-power Beam Width Adjust. Electr.

Downtilt Enhanced Sidelobe Suppression

1710 2200 X 65 0 15 18dB

1710 2200 X 65 0 15 18dB

Downtilt set by hand or by optional RCU (Remote Control Unit)


XXPol Panel 17102200/17102200 65/65 18/18dBi 015/015T ESLS
Type No. Frequency range 1710 1880 MHz Polarization Gain at 0 tilt Horizontal Pattern: Half-power beam width Front-to-back ratio (180 30) Cross polar ratio Sector Vertical Pattern: Half-power beam width Electrical tilt 7.9 7.5 7.2 6.9 0 15, continuously adjustable 0 60 65 30 dB 24 dB 9 dB 63 30 dB 24 dB 9 dB 62 30 dB 24 dB 10 dB 62 28 dB 26 dB 10 dB 4 x 17.5 dBi

800 10510
17102200 1850 1990 MHz 1920 2170 MHz 4 x 17.6 dBi 4 x 17.7 dBi 2000 2200 MHz 4 x 17.8 dBi +45, 45; +45, 45 +45, 45; +45, 45 +45, 45; +45, 45 +45, 45; +45, 45

0 ... 5 ... 10 ... 15 T 0 ... 5 ... 10 ... 15 T 0 ... 5 ... 10 ... 15 T 0 ... 5 ... 10 ... 15 T Sidelobe suppression for first sidelobe above main beam 17 ... 20 ... 18 ... 17 dB 16 ... 20 ... 18 ... 18 dB 15 ... 19 ... 18 ... 17 dB 14 ... 18 ... 18 ... 16 dB within 020 sector above horizon 17 ... 18 ... 18 ... 16 dB 16 ... 17 ... 17 ... 16 dB 15 ... 17 ... 17 ... 16 dB 14 ... 16 ... 16 ... 15 dB Null-fill at 0 tilt Impedance VSWR Isolation, between ports Intermodulation IM3 Max. power per input 23 dB 22 dB 50 < 1.5 > 30 dB < 153 dBc (2 x 43 dBm carrier) 300 W (at 50 C ambient temperature) 21 dB 20 dB

1710 1880 MHz: +45/ 45 Polarization


125 66
7.9

10 3 0

10

3 0

1710 2200 +45

1710 2200 45

1710 2200 +45

1710 2200 45

Horizontal Pattern

dB

Vertical Pattern 0 15 electrical downtilt

dB

1850 1990 MHz: +45/ 45 Polarization


120 65 7.5

7-16

7-16

7-16

7-16

Mechanical specifications Input Connector position Adjustment mechanism Weight Wind load Frontal: Lateral: Rearside:
dB

Subject to alteration.

4 x 7-16 female Bottom 2 x, Position bottom continuously adjustable 17 kg 600 N (at 150 km/h) 120 N (at 150 km/h) 650 N (at 150 km/h) 200 km/h 1686 x 337 x 112 mm 1389 / 323 / 71 mm

10

10

dB

3 0

3 0

Horizontal Pattern

Vertical Pattern 0 15 electrical downtilt

1920 2200 MHz: +45/ 45 Polarization


115 63 7.1

936.3161/c

Max. wind velocity Packing size Height/width/depth


dB

10

10

dB

3 0

3 0

Horizontal Pattern Internet: http://www.kathrein.de

Vertical Pattern 0 15 electrical downtilt

800 10510

Page 1 of 4

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494

Accessories General Information


Accessories (order separately)
20 Type No. 738 546 850 10002 850 10003 737 974 Description 1 clamp 1 clamp 1 clamp 1 downtilt kit Remarks Mast: 50 115 mm diameter Mast: 110 220 mm diameter Mast: 210 380 mm diameter Downtilt angle: 0 15 Weight approx. 1.0 kg 2.7 kg 4.8 kg 2.8 kg Units per antenna 2 2 2 1 72 64 9 254 48 41 71 98 323 Bottom view 45 45 RCU +45 +45 17102200 Left Right 17102200 RCU Layout of interface Please note: As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions. The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4, which includes the static mechanical load imposed on an antenna by wind at maximum velocity. Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna or even cause it to fall to the ground. These facts must be considered during the site planning process. The installation team must be properly qualified and also be familiar with the relevant national safety regulations. The details given in our data sheets have to be followed carefully when installing the antennas and accessories. The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must be obeyed. Any previous datasheet issues are invalid.
Subject to alteration. 936.3161/c Internet: http://www.kathrein.de

For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Wall mounting: No additional mounting kit needed. Material: Reflector screen: Tin-plated copper. Radiator: Tin-plated zinc. Flat fiberglass radome: The max. radome depth is only 71 mm. Fiberglass material guarantees optimum performance with regards to stability, stiffness, UV resistance and painting. The colour of the radome is grey. All screws and nuts: Stainless steel. The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded. 1389 1436 1494 1636 Adjustment mechanism with integrated scale 30

Grounding:

Environmental conditions: Kathrein cellular antennas are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E. The antennas exceed this standard with regard to the following items: Low temperature: 55 C High temperature (dry): +60 C Ice protection: Due to the very sturdy antenna construction and the protection of the radiating system by the radome, the antenna remains operational even under icy conditions. Environmental tests: Kathrein antennas have passed environmental tests as recommended in ETS 300 019-2-4. The homogenous design of Kathreins antenna families use identical modules and materials. Extensive tests have been performed on typical samples and modules.

Page 2 of 4

800 10510

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494

General Instructions for Adjustment Mechanism

Description of the adjustment mechanism (protective cap removed):

2 2

Adjustment wheel with twist-lock function. Downtilt spindle with integrated scale.

Thread for fixing the protective cap or the RCU (Remote Control Unit). Gearwheel for RCU power drive.

To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gearwheel must be used for alignment.

Manual adjustment procedure:

0 max.

max. 0

Remove the protective cap.

Set downtilt angle by rotating the adjustment wheel.

Screw on the protective cap again.

Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment:


Subject to alteration. 936.3161/c

For a description of RCU installation please refer to the respective data sheet.
Internet: http://www.kathrein.de

800 10510

Page 3 of 4

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494

General Instructions for Feederline Installation on Panels with four Connectors arranged on two Levels
Please note: In order not to damage the interfaces, please make sure that only the right tools are used. Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench width.

Description of connector arrangement:

There are four interfaces for feeding the antenna located at the bottom.

The connectors are mounted at two levels in order to facilitate feederline installation.

Attachment of the feederline connector and RCU (optional):


In order to protect the adjustment mechanism the protective caps have to be attached during feederline installation!

Start with the rearside located interface no. 1. Place the connector carefully and fix the nut using a torque-wrench (according to the manufacturers guidelines). The further sequence for the installation is: feederlines no. 2, 3, 4.

After feederline installation the optional remote control units (RCU) can be mounted if required.

For a full description of RCU installation please refer to the respective data sheet.

Please note: Additional weather sealing of correctly installed feederline connector interfaces is not required, nor is it recommended by the connector manufacturers.