You are on page 1of 172

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 2 of 23

TABULATION OF REVISED PAGES

PAGE

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34

D0 * * * * * * * * * * * * * * * * * * * * * * * * *

Revision D1 D2

PAGE

D0

Revision D1 D2

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 3 of 23

TABLE OF CONTENTS
TABULATION OF REVISED PAGES .................................................................................................................. 2 TABLE OF CONTENTS ......................................................................................................................................... 3 1. INTRODUCTION ............................................................................................................................................ 5 1.1. 1.2. 1.3. 1.4. 1.5. 1.5.1. 1.5.2. 1.5.3. 2. 3. 4. GENERAL ................................................................................................................................................. 5 DEFINITION .............................................................................................................................................. 5 ABBREVIATION ........................................................................................................................................ 6 SCOPE OF THIS DOCUMENT ....................................................................................................................... 6 REFERENCES ............................................................................................................................................ 7 General Specifications ........................................................................................................................ 7 Construction Procedures and Specifications ...................................................................................... 7 Drawings ............................................................................................................................................ 7

SITE DESCRIPTION FOR EXPORT PIPELINE ....................................................................................... 7 CONCRETE MATTRESSES SPECIFICATIONS ..................................................................................... 8 MARINE FLEET ............................................................................................................................................. 9 4.1. 4.2. CONSTRUCTION AND INSTALLATION VESSEL ........................................................................................... 9 TRANSPORTATION VESSEL ....................................................................................................................... 9

5.

RESPONSIBILITIES OF KEY PERSONNEL .......................................................................................... 10 5.1. 5.2. 5.3. 5.4. 5.5. SUPERINTENDENT .................................................................................................................................. 10 FIELD ENGINEER ..................................................................................................................................... 10 DIVING SUPERINTENDENT ...................................................................................................................... 10 SURVEY PARTY CHIEF ........................................................................................................................... 10 VESSEL CAPTAIN ................................................................................................................................... 10

6. 7.

MATTRESS FABRICATION ...................................................................................................................... 11 MATTRESS INSTALLATION .................................................................................................................... 11 7.1. 7.2. 7.3. 7.4. 7.5. 7.6. WEATHER CRITERIA .............................................................................................................................. 11 SURVEY DEFINITION OF THE CROSSING POINTS ..................................................................................... 11 MOBILIZATION ....................................................................................................................................... 11 TRANSPORTATION .................................................................................................................................. 12 CALIBRATION OF SURVEY EQUIPMENTS ................................................................................................. 12 OFFSHORE INSTALLATION SEQUENCE .................................................................................................... 12

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 4 of 23

7.6.1. 7.6.2. 7.6.3. 7.6.4. 7.6.5. 7.6.6. 7.6.7. 7.6.8. 7.6.9.

Locating the Crossing Point ............................................................................................................. 12 Crossing Point Verification .............................................................................................................. 12 Transfer the Mattresses to the Deck of Installation Vessel ............................................................... 12 Installation of Positioning Equipment .............................................................................................. 13 Installation of Rigging Items ............................................................................................................ 13 Vessel Positioning On Mattress Installation Coordinates ................................................................ 13 Lifting and Lowering the Mattress.................................................................................................... 13 Lead the Mattress to the Exact Coordinates on Seabed ................................................................... 13 Detach Installation Equipment ......................................................................................................... 13

7.6.10. Continue Installation of Other Mattress ........................................................................................... 14 7.6.11. Perform Final Diver Visual Survey for Crossing Location .............................................................. 14 7.6.12. Preparation of Installation Reports .................................................................................................. 14 7.6.13. Proceed to the Next Crossing Location ............................................................................................ 14 7.7. 7.8. INSTALLATION ENGINEERING AND CALCULATION ................................................................................. 14 FINAL REPORT ........................................................................................................................................ 15

ATTACHMENT 1: LIST OF CROSSINGS ........................................................................................................ 16 ATTACHMENT 2: MATRRESS DOCUMENTS ............................................................................................... 17 ATTACHMENT 3: GERIMAL SPECIFICATION ............................................................................................ 18 ATTACHMENT 4: CRANE CHART .................................................................................................................. 19 ATTACHMENT 5: DIVING PROCEDURE ....................................................................................................... 20 ATTACHMENT 6: SURVEY QUALITY PLAN ................................................................................................ 21 ATTACHMENT 7: PROJECT TIME SCHEDULE ........................................................................................... 22 ATTACHMENT 8: LIFTING FRAME ARRANGEMENT .............................................................................. 23

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 5 of 23

1.

INTRODUCTION

1.1. General
Petroiran Development Company (PEDCO) intends to further develop the Foroozan Oil and Gas Fields located in Iranian waters of the Persian Gulf. The Foroozan Field is located in the Persian Gulf, approximately 100km south-west of the Kharg Island. The field straddles the Iran-Saudi Arabia border. The integrated development project foresees the construction of up to 2 new platforms (EPC 1). PEDCO has commissioned IOEC to design and construct the new Foroozan pipeline scope under the EPC 2 contract. IOEC has contracted INTEC Engineering BV for the detailed design of the submarine pipelines, risers and power-Opto cable (functional requirements by EPC 1 contractor Saipem Triune). The new Foroozan pipelines to be installed include: 24" Gas Export Pipeline between the Foroozan Field and Kharg Island 18" Sour Gas Transfer Pipeline between Foroozan production complexes 8" Crude Oil Test Lines to test the production of wells at Wellhead Platforms 4", 6" and 8" Gas Lift pipelines to increase production at Wellhead platforms

One subsea Power-Opto cable is included in EPC2 Scope of Work, within the Foroozan Field from FZ-A to FX.

1.2. Definition
IOOC: PEDCO: IOEC: SPEC: Owner - Iranian Offshore Oil Company Client - PETROIRAN Development Company Contractor-Iranian Offshore Engineering and Construction Company Subcontractor-Subsea Pipeline Engineering Company

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 6 of 23

1.3. Abbreviation
KP DSV DP LUSBL SAT Kilometer post Diving support vessel Dynamic positioning Long and Ultra-Short Baseline Saturation diving system

1.4. Scope of this document


This document presents the requirements for the existing pipeline crossing installation activities for FOROZAN 24 export gas Pipeline. Scope of this document comprises required procedures, calculation, specification and drawings for fabrication, transportation and installation of crossings. The document contains brief description of site in the second part and after that Mattress specification in the third part which has been supported by attachment 2. The marine fleet is addressed in the fourth part and responsibilities of key personnel presented on fifth section. The sixth part is fabrication which has been supported by mattress document presented in attachment 2. Next section is demonstration of operation sequence in offshore. Also, the detail procedure of diving and positioning activities in addition to sketches, specifications and tables are provided in attachments of this document.

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 7 of 23

1.5. References
1.5.1. General Specifications

1. GL Noble Denton Guidelines for Marine Lifting Operations 1.5.2. Construction Procedures and Specifications

0027/ND Rev9

1. Pipeline Crossing Design Report 1.5.3. Drawings

FE560-0000-PL-RT-1038/D2

1. Typical pipeline crossing layout 2. Pipeline crossing location overview 3. Route overview in field lines FOROZAN field 4. Alignment sheet 5. Crossing support arrangement

FE560-0000-PL-DW-1040/D0 FE560-0000-PL-DW-1039/D2 FE560-0000-PL-DW-1301/D3 FE560-GEXP-PL-DW-1301 FE560-0000-PL-DW-1657/D0

Note: All basic references subject to be provided or updated by contractor. Consequently, this procedure may have major changes in upcoming revisions.

2.

SITE DESCRIPTION FOR EXPORT PIPELINE


Offshore site where installation work is to be carried out is Foroozan field, located 100 Km farther of Kharg Island. 24" Gas Export Pipeline between the Foroozan Field and Kharg Island will cross existing pipe lines and cables in abut 11 points, the approximate water depth range is from 0 to 55 meters.

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 8 of 23

3.

CONCRETE MATTRESSES SPECIFICATIONS


FOROZAN pipeline crossing will be carried out by using the concrete mattresses, which will be supplied by SPEC, manufactured by ULO. Mattresses are fabricated in two types of side lift flexible, based on concrete mix table (attachment 2). One of them equipped with rubber and will be in direct contact with pipelines. The other type will be placed on top of the first type and will not be in direct contact with pipe line. Concrete density is 2400 kg/m3, class 40. Ropes are 16mm polypropylene UV resistance for lateral in addition to 20mm for longitudinal, and lifting. The dimension of the mattresses is 6m by 4m as shown in below sketch and total weight is 10.9 ton in air and 6.2 ton in water. The mattresses drawings are presented in attachment 2.

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 9 of 23

4.

MARINE FLEET

4.1. Construction and Installation Vessel


GERIMAL (Attachment 3) a DP-2 diving Support vessel has been nominated as installation vessel. The vessel has been equipped with a HITACHI KH230 built in crane with 40 tons lifting capacity and another KOBELCO CKE1350 mobile crane with 135 tons lifting capacity (Attachment 4). Also, SAT diving equipment to support operation during 24 hours is ready to use on board of GERIMAL. In addition to all above equipments, a small fabrication workshop will be mobilized to support minor fabrication activities. This vessel has enough deck space and accommodation to support operation.

4.2. Transportation Vessel


Considering design limitation and availability of vessels on market, subcontractor will use a suitable vessel to deliver the mattresses to installation site.

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 10 of 23

5.

RESPONSIBILITIES OF KEY PERSONNEL

5.1. Superintendent
The superintendent is responsible for all installation operations; therefore, he will review and note all installation documents and shall perform the job accordingly. Any probable issue with respect to engineering has to be checked by field engineer and will be sorted out by assistance of the superintendent.

5.2. Field engineer


The Field engineer is overall responsible for monitoring mattress installation activities in accordance with engineering procedures, specification and construction drawings. The field engineer should supervise all installation jobs and issue the reports.

5.3. Diving Superintendent


The Diving Superintendent qualified & certified for all diving jobs, shall supervise the diving activities and endorse the reports which are prepared by diving team. The diving safety procedure shall exactly be followed by him according to the international codes and standards.

5.4. Survey Party Chief


As the leader of the surveying team, the party chief is responsible for all survey activities. Also, He is responsible for final reports preparation. Party chief will manage survey activities in corporation with captain and superintendent.

5.5. Vessel Captain


According to the marine rules and regulations the vessel Captain is generally responsible for the all activities which is going to be performed onboard of vessel. He is responsible through all personnel lives; therefore, he will be informed about every activity in general on daily basis and in a short brief meeting. Also the captain notifies the project coordinator all requirement of the vessel to be prepared.

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 11 of 23

6.

MATTRESS FABRICATION
All mattresses will be fabricated by ULO, complete information about the fabrication is provided in Attachment 2

7.

MATTRESS INSTALLATION
Upon completion of the documentation, mobilization of the installation vessel, the installation vessel shall move into the field, meanwhile transportation of the mattresses shall be arranged. The installation of mattresses will be carried out by assistance of the positioning and the diving teams. The general procedures of each discipline are presented separately in attachment 5 for diving and 6 for positioning.

7.1.

Weather Criteria
The lifting and lowering operation has to be performed in safe condition. Considering the vessel, diving and crane limitations, superintendent or his deputy are responsible to make assessment regarding sea state and start of the operation in safe condition. During whole operation, the weather forecast reports shall be provided to Installation Vessel and Project Team by MET Marine Forecast.

7.2.

Survey Definition of the Crossing Points


The location of the crossing points are as shown in the Attachment.1 with the defined coordinates in reference (to be provided by contractor) prepared by (to be provided by contractor). Diver will check the location of each crossing point and existing pipelines to verify the information provided by client. In case of any nonconformity diver will try to find the pipeline within a range of 20 meter. The new data will be sent to positioning team on surface enabling them to prepare corrective report and after obtaining approval of the new point by contractor, new coordinates will be applied to continue the operation.

7.3. Mobilization
Based on the presented Project Time Schedule (attachment 7), SPEC will mobilize the DSV DP2 GERIMAL in Port KHALID, SHARJAH, UAE. The diving, positioning, and marine crew will join the vessel during mobilization. All equipment fabrication, equipment tests and trial operations will be carried out alongside the jetty and during this period.

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 12 of 23

7.4. Transportation
As part of the project scope of work, subcontractor will mobilize the transportation vessel and load mattresses on it based on fabricator instruction. Mattresses will be delivered to installation site prior to start of the operation.

7.5. Calibration of survey equipments


Prior to installation operation the positioning team will carry out calibration operation for their equipment. The detail information for this part of the project is provided in attachment 6

7.6. Offshore Installation Sequence


Consequently, and upon completion of preparatory works and contractor permission for sail out, vessel will sail to the offshore site. The installation sequence demonstrates the main activities of the target operation and the relations between each activity. The general procedures of diving and positioning activities are attached to this document. The sequences of work when the vessel at location shall be as follows:

7.6.1.

Locating the Crossing Point

As the first step of installation activity, and based on positioning team instruction, the vessel takes position on top of the crossing point defined and provided by the client.
7.6.2. Crossing Point Verification

After positioning the vessel on top of the crossing point, diver will check the exact position of existing pipe line by using beacon and assist of sector scan sonar. If diver couldnt find the existing pipe or cable a visual survey will carry out in the range of 20 meter. This data will be sent to the surface and positioning team compares it with client data. In case of any nonconformity the operation will be held on standby for client instruction. During the verification, positioning team will record two coordinates on pipeline and use these coordinates as reference to recheck the position of pipeline.
7.6.3. Transfer the Mattresses to the Deck of Installation Vessel

After verification of the crossing final coordinate the installation vessel will go along side of transportation vessel and by using on board cranes transfers mattresses to installation vessel deck. It should be noted that the first mattress must have rubber to prevent any damage to pipeline

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 13 of 23

7.6.4.

Installation of Positioning Equipment

The positioning equipment will set up on a lifting frame prior to the lifting. This equipment contains two compatts in each side of the frame. By using these two compatts surveyors will be able to locate the exact coordinate of crossing point and match it with the proposed coordinate.
7.6.5. Installation of Rigging Items

Riggers will install the mattress lifting frame by connecting the side lifting ropes to the frame and secure the pins. On the other side the frame will be connected to the crane hook with 4 wire slings and will be prepared for lifting. The arrangement is shown in attachment 8
7.6.6. Vessel Positioning On Mattress Installation Coordinates

Positioning team will lead vessel to the coordinates, which has been adjusted according to crane geometry on the vessel and sea bed position of the crossing. In this way when the vessel stands on this position, the mattress will be lowered down directly to the final installation position.
7.6.7. Lifting and Lowering the Mattress

After confirmation of the vessel position by surveyors, lifting operation will start under supervision of the superintendent. In this part the mattress will lift off from deck and smoothly guided to the lowering position. Mattress will lower down to the sea bed up to 1.5 meter above the sea bed. The surveying team will assist superintendent, using sector scan sonar and LUSBL to monitor lowering operation real time. This device will show the relative position of the support and the existing pipe line. Meanwhile diver will monitor the arrival of mattress on sea bed and assist superintendent to start the next level of operation.
7.6.8. Lead the Mattress to the Exact Coordinates on Seabed

In this stage diver will adjust mattress position and orientation with instructions he receives from the superintendent and the surveyor on surface. Again LUSBL system gives the exact coordinates and sector scan sonar visually shows the situation. After final check and confirmation of the position by surveyors, support will lower down to the sea bed.
7.6.9. Detach Installation Equipment

By completion of the previous stage of operation the load will be released from crane and diver proceed to detach mattress from the frame. Also, the positioning equipment will be released and recovered to the surface.

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 14 of 23

7.6.10. Continue Installation of Other Mattress

Considering the fact that most crossing location consist more than one mattress, the above operation has to be repeated for each support.
7.6.11. Perform Final Diver Visual Survey for Crossing Location

The final visual check after completion of installation will be performed to prepare a video report.
7.6.12. Preparation of Installation Reports

Different types of reports will be prepared during installation, detail information of each report provided in attached procedures. These reports comprise daily progress, activity completion or data confirmation.
7.6.13. Proceed to the Next Crossing Location

After completion of the surveys and approval of the installation condition by client, the installation vessel will shift to the next crossing location. Obviously above steps will be repeated until the whole project scope of work accomplished satisfactorily.

7.7. Installation Engineering and Calculation


Engineering calculation carried out to select proper rigging and crane. These calculations are in accordance with reference 1.5.1.1. Below table shows the results of lifting calculation

Sling Design
Net Weight above water Net Weight under water Rigging weight Static Hook Load Dynamic Amplification Factor Dynamic Hook Load no. of slings Skew load factor Sling Angle Sling Vertical Load Sling Load Safety Factor Termination Efficiency Factor Bending Efficiency Factor Wire Rope MBL Sling Unity Check 10.9 6.2 2.2 13.1 1.3 17.03 4 1.25 1.047198 4.2575 10.64375 2.25 0.5 1 92 0.130155

Unit
ton ton ton ton

rad ton ton ton -

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 15 of 23

These calculations are based on rigging presented in attachment 8 and using1.5 inch wire slings. In addition to above calculation the calculation regarding the mattress rope verification is provided in attachment 2. According to installation vessel and position of the crane maximum required radius for lifting operation is not more than 16 meter. On the other hand the maximum expected load of the mattress is 13.4 tons. Consequently, as the crane chart shows (Attachment 4) the crane is suitable to handle this load.

7.8. Final report


After completion of project a complete report will be prepared based on client request. This report contains all documents, DPRs, completion reports, drawings, survey reports, etc.

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 16 of 23

Attachment 1: CROSSINGS LIST AND ARRANGEMENTS


(To be clarified by CONTRACTOR)

Crossing FE-C01 FE-C02 FE-C03 FE-C04 FE-C05 FE-C06

Client Supplied Crossing Details -24"FZA-KHARG Pipeline/cable ID Quantity support No. Unknown KHARG to LAVAN,SIRI cable Terminal AC2882/Oil pipeline ARDESHIR to DARIUS Falcon-S07a-RPL-PL06-Abridged FOG cable Falcon-S06b-RPL-PL01-Abridged
4+4 1+1 1+1 1+1 1+1 1+1 1 1 1 1 1

Support Type A A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene B

KP 7.690 8.705 18.957 69.113 73.880 74.827 96.804 96.804 96.804 96.804 100.513 100.513 100.513 101.010 101.010 101.010 101.010 101.802 101.802 101.802 101.802 101.960

Support Coordinates Easting ioec Northin ioec 424921.52 424372.42 418814.96 391626.85 389042.86 388529.03 376609.94 376613.94 376617.94 376622.20 375075.20 375081.31 375087.42 374850.37 374854.30 374858.38 374862.01 374557.73 374561.20 374564.67 374568.14 374523.84 3232569.47 3231718.20 3223103.16 3180956.18 3176950.49 3176153.95 3157672.59 3157681.76

Easting ioec 424918.86 424372.42 418814.96 391626.85 389042.86 388529.03

Easting hsc 424957.00 424372.00 418815.00 391627.00 389043.00 388529.00

Crossing Coordinates difference Northin ioec -38.14 0.42 -0.04 -0.15 -0.14 0.03 3232565.29 3231718.20 3223103.16 3180956.18 3176950.49 3176153.95

Northin hsc 3232561.00 3231718.00 3223104.00 3180957.00 3176950.00 3176154.00

difference 4.29 0.20 -0.84 -0.82 0.49 -0.05

Support Angles to Route to North Grid 33.00 33.00 33.00 33.00 33.00 33.00 24.00 24.00 82.00 93.00 68.00 73.00 69.00 71.00 66.00 66.00 69.00 69.00 56.00 56.00 56.00 67.00 67.00 67.00 67.00 25.00 25.00 25.00 25.00

FE-S01 FE-S02 FE-S03 FE-S04 FE-S05 FE-S06 FE-S07 FE-S08 FE-S09 FE-S10 FE-S11 FE-S12 FE-S13 FE-S14 FE-S15 FE-S16 FE-S17 FE-S18 FE-S19 FE-S20 FE-S21 FE-S22

FE-C07

Sub sea Cable for LAVAN,SIRI,KHARG and BAHREGAN District

376615.94 3157690.92 3157699.95 3154330.30 3154339.46 3154348.63 3153883.41 3153892.61 374856.34


1 1 1 1

376616.00

-0.06

3157686.34

3157686.00

0.34 25.00 25.00 34.00

FE-C08

Sub sea Cable for LAVAN,SIRI,KHARG and BAHREGAN District

1 1 1 1

375081.31

375081.31

3154339.46

3154339.46

34.00 34.00 21.00 21.00

FE-C09

16" product flow line F-17 to FZ 3153902.99 3153912.24 3153154.64 3153162.94

374859.00

-2.66

3153897.80

3153902.00

-4.20 21.00 21.00 67.00 67.00

FE-C10

16" product flow line F-17 to FZ


1 1 3+3

374563.05 3153171.25 3153179.55 3152924.33 374530.48

374563.00

0.05

3153167.03

3153169.00

-1.97 67.00 67.00

FE-C11

374531.00

-0.52

3152966.87

3152971.00

-4.13

N.I.O.C

N.I.O.C

N.I.O.C

N.I.O.C

N.I.O.C

N.I.O.C

N.I.O.C

N.I.O.C

N.I.O.C

N.I.O.C

N.I.O.C

FE-C11

3+3 4+4

FE-S23 FE-S24

B A

101.960 101.960

374227.75 374532.64

3152949.70 3152980.55

374530.48

374531.00

-0.52

3152966.87

3152971.00

-4.13

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 17 of 23

Attachment 2: MATRRESS DOCUMENTS

QUALITY RECORD 2
PROJECT LOCATION SPEC Ship Management Concrete Mattresses Hamriyah Free Zone, Sharjah, UAE Job No. 0029-05-2010-B IGO SUPERVISOR Simon Jones

QR2

FLXMAT CAST __________________m Serial Numbers FLXMAT CAST __________________m Serial Numbers

CONCRETE DELIVERY LOG


BATCH # TRUCK ID DOCKET # VOL FLXMAT STARTED FLXMAT COMPLETE DATE TEST CUBE REF

ENTER TEST CUBE No. only when test cubes are made of the batch of concrete delivered This document shall be completed by the onsite Supervisor during the fabrication for each type of FLXMAT listed within the SOW F-79

QUALITY RECORD 1
PROJECT LOCATION IGO SUPERVISOR SPEC Ship Management Concrete Mattresses Hamriyah Free Zone, Sharjah, UAE Simon Jones Job No. 0029-05-2010-B DATE MATTRESS SIZE 6x4x0.3m

QR1

PREPARATION AND SITE INDUCTION


Item 1. 2. 3. 4. 5. Prestart Activities New employees (if any) inducted? Review with staff of latest mattress drawing to be assembled? Reviewed currently location on working ITP to ensure work can commence? Stock numbers checked and enough material to complete scope? Daily toolbox and safety meeting Check

MANUFACTURING CHECK
Item 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Item 11. 12. 13. 14. 15. Assembly Activities Clips placed in correct locations (Base). Check correct length/width (Base). Install long. Ropes and check correct rope . Install Lat. Ropes and check correct rope . Fix top shell, check positive connection with all clips to upper shell. Set lifting rope length as per design specification. Splices are correct and within centre of mattress and shell. Recheck all clips and screw any broken or insufficient clips. Lay mattress on PVC sheet checking ground for loose debris. Clearly mark mattress according to Execution Plan. Casting Activities Check concrete truck docket and note truck number discharged into mattress. Fill each shell with concrete and vibrate carefully. Trowel tops off neatly and wash down all blocks with water including lifting ropes. Check FLXMAT shells for any openings or excessive distortion. Leave mattress to cure for 3 days prior to stacking or relocating
This document shall be completed by the onsite Supervisor during the fabrication for each type of FLXMAT listed within the SOW F-80

FLXMAT SERIAL NUMBER

Lifting & Placing Frame


ULO No : LPF 009, LPF 011, LPF 012, LPF 013

Capacity (SWL) : 25 Tons Self Weight : 2.0 tons OAll Dimensions : 6020 W x 3000 / 2000 D x 1040 H

, ULO Systems LLC, 1 June 2001

Working Dimensions are shown in Millimetres as required ON DECK


POWER NIL WATER NIL AIR NIL

ULO Policy on Testing Equipment and certified by 3rd party


Load Test to 2.5 times SWL at New Fabrication Visual Inspection: Every 12 months Lifting Slings & Wire Rope as per DAC 2006. LOLER 1998 and article (20) decree32, 1982 Non Destructive Test at New Fabrication Visual Inspection : Every 6 months

This photograph is indicative of the equipment for the above description but ULO Systems LLC reserve the right to make any alterations deemed necessary.

PROJECT QUALITY PLAN


PROJECT INSPECTION AND TEST PLAN
QUALITY ASSURANCE SYSTEM W = WITNESS (Notification Required) I = INSPECT A = APPROVAL H = HOLD POINT R = REVIEW OF DOCUMENT M = MONITOR Prepared By: Jackson Dryne Signed: Date: Approved By: Harvey Lee Signed: Client Approval By: Signed: PREPD BY ACCEPTANCE CRITERIA Date: Date: DOCUMENT/ RECORD FORM S = SAMPLE REQUIRED

Page 1 of 4

CLIENT = SPEC Ship Management SSM IGO = International Grout Operations INC SS = Onsite Supervisor Eng = Project Engineer Mgmt = Project Management

PROJECT SCOPE PURCHASE ORDER NO: ITP No.: ITEM No. 1.0

SPEC Ship Management Concrete Mattresses 30No. 6x4x0.3m Concrete Mattress (Standard) 23No. 6x4x0.3m Concrete Mattress with Rubber base

10205PO-01 FLX-ITP-0029-05-2010-B - REVA

INSPECTION ACTIVITY

COMMENT

INSPECTION SURVEILLANCE CODE IGO Client Asset

PRE-EXECUTION ACTIVITIES W = WITNESS, I = INSPECT, H = HOLD POINT, R = REVIEW OF DOCUMENT, M = MONITOR Mattress Construction Drawings 0029-05-2010B-DWG-071110-01-REVA (No rubber) 0029-05-2010B-DWG-071110-01-REVC (Inc rubber) Lift Rope Verification Execution Plan Rope Certification Concrete Mix Design IGO Eng Client Approval H R, A A

1.1

1.2 1.3 1.4 1.5

IGO Eng IGO Mgmt IGO Mgmt IGO Mgmt

Client Approval Client Approval Item 1.2 ITP DNV Pt 2, Ct 5 Client Approval

FLX-ENG-LIFT FLX-EP-0029-052010-B Vendor Supplied Certification Vendor Supplied Report

Calculation in accordance to DNV Pt 2, Ct 5

H H H H

R, A R, A R, A R

F-064-D

PROJECT QUALITY PLAN


ITEM No. 2.0 2.1 2.2 2.3 2.4 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 ACCEPTANCE CRITERIA DOCUMENT/ RECORD FORM

Page 2 of 4

INSPECTION ACTIVITY

BY

COMMENT

INSPECTION SURVEILLANCE CODE IGO Client

SITE ESTABLISHMENT W = WITNESS, I = INSPECT, H = HOLD POINT, R = REVIEW OF DOCUMENT, M = MONITOR Supervisor reviews all documents within Section 1.0 of ITP with Project Manager. Check component stock and ensure sufficient quantities are onsite in order to complete scope of work Select suitable FLXMAT assembly and casting area Completion of Personnel Site Induction including Tool Box Safety Meeting IGO SS IGO SS/ MGMT IGO SS IGO SS Section 1.0 ITP all approved ITP, DPR DPR Section 4.2 Execution Plan Execution Plan DPR Record stock levels within DPR R I I M

FLXMAT ASSEMBLY W = WITNESS, I = INSPECT, H = HOLD POINT, R = REVIEW OF DOCUMENT, M = MONITOR FLXMAT shells are laid out and clipped together. The Mat Dwg, QR1 bottom half of the mattress is clipped together until the IGO SS Execution Plan length and width match that of the construction drawing. Mat Dwg, QR1 Lateral and longitudinal ropes are pre-cut. IGO SS Execution Plan Lateral and longitudinal ropes are installed throughout the bottom half of the clipped mattress. Rope ends are terminated using an open splice toward the centre of the mattress and shell. If design includes edge lift ropes then these should be installed as per instruction noted on mattress construction drawing. Lifting ropes are set to designed length. Top shell is fixed to the bottom shell creating complete block. Mattresses are relocated to casting area and positioned on polythene sheets. Remaining QR1 checks are complete. IGO SS IGO SS IGO SS IGO SS IGO SS Mat Dwg, Execution Plan Mat Dwg, Execution Plan Mat Dwg, Execution Plan Mat Dwg, Execution Plan Mat Dwg, Execution Plan QR1 QR1 QR1 QR1 QR1

I, A I, A I, A I, A I, A I, A I, A

R M M M M M M

3.8

IGO SS

I, A

F-064-D

PROJECT QUALITY PLAN


ITEM No. 3.9 4.0 4.1 4.2 ACCEPTANCE CRITERIA Section 5.4 of Execution Plan DOCUMENT/ RECORD FORM QR1

Page 3 of 4

INSPECTION ACTIVITY Mattress is clearly marked according to Section 5.4 of Execution Plan

BY

COMMENT

INSPECTION SURVEILLANCE CODE IGO Client I, A M

IGO SS

FLXMAT CASTING W = WITNESS, I = INSPECT, H = HOLD POINT, R = REVIEW OF DOCUMENT, M = MONITOR Concrete delivery to site in mixer trucks. Check, approve and collect delivery receipt. Discharge concrete and fill mattresses. Record mattress serial number each truck commences and finishes on. Cubes are made at concrete batching plant (6 No. per truck) and crushed at 7 & 28 day (3 No. per test). Cast blocks, screed off top and wash down to complete fabrication. Check FLXMAT shells for any openings or excessive distortion. Confirm Number of Cast Mattress Daily activity Record of Daily progress onsite including man hours and any lost hours activities, accidents or industrial dispute. IGO SS IGO SS Section 5.2 of Execution Plan, ASTM C109, BS 1881 Part 108 1983 Section 4.4 of Execution Plan Section 4.4 of Execution Plan Concrete delivery docket, QR2 QR2 I, A M M M

4.3

3rd Party

Vendor Supplied Report

4.3 4.4 4.5 5.0 5.1 5.2 5.3

IGO SS IGO SS IGO SS

QR2 DPR DPR

I, M I, M M

M M M

FLXMAT STORAGE AND HANDLING W = WITNESS, I = INSPECT, H = HOLD POINT, R = REVIEW OF DOCUMENT, M = MONITOR 3 Days curing of mattresses Stacking of mattress using correct SWL handling frame and rigging equipment Mattresses should be stored in a shaded/covered area for long periods (greater than 3months). IGO SS IGO Eng IGO Mgmt Section 4.5 of Execution Plan Section 4.5 of Execution Plan Section 4.5 of Execution Plan M I M

F-064-D

PROJECT QUALITY PLAN


ITEM No. 6.0 6.1 6.2 ACCEPTANCE CRITERIA DOCUMENT/ RECORD FORM

Page 4 of 4

INSPECTION ACTIVITY

BY

COMMENT

INSPECTION SURVEILLANCE CODE IGO Client

INSTALLATION FRAME ACTIVITIES W = WITNESS, I = INSPECT, H = HOLD POINT, R = REVIEW OF DOCUMENT, M = MONITOR Mattress Rigging and Installation Procedure Installation Frame inc Mattress drawing IGO Eng IGO Eng IGO Mgmt, 3rd Party IGO Mgmt Client Approval Client Approval Frame and rigging certification witnessed by 3rd party MRB FLX-IP-0029-052010-B M M R, A R, A

6.3

Installation Frame and Rigging certification documents

Client Approval Section 7.0 of Execution Plan

R, A

6.3 7.0 7.1 7.2

Submission of MRB (Manufacturer Record Book)

POST EXECUTION ACTIVITIES W = WITNESS, I = INSPECT, H = HOLD POINT, R = REVIEW OF DOCUMENT, M = MONITOR Delivery Mattresses to Client Submission of MRB (Manufacturer Record Book) IGO Mgmt IGO Mgmt Purchase Agreement Section 7.0 of Execution Plan Delivery Docket MRB M M M A

F-064-D

Document No: FLX-EP-0029-05-2010-B

Document Title:

Precast Concrete Mattress EXECUTION PLAN

A REV

22/11/10 DATE

Issued for client approval DESCRIPTION

JD BY

HL CHK CLIENT APP

Execution Plan TABLE OF CONTENTS


1.0 INTRODUCTION ..........................................................................................................................2 2.0 REFERENCES ................................................................................................................................2
2.1 APPLICABLE CODES AND STANDARDS .............................................................................................................................. 2 2.2 INTERNAL QA/QC DOCUMENTS ............................................................................................................................................ 3 2.3 PROJECT SPECIFIC ENGINEERING DOCUMENTS ......................................................................................................... 3 2.4 EXTERNAL CERTIFICATION AND DOCUMENTATION ............................................................................................... 3

3.0 SCOPE OF WORKS ........................................................................................................................4 4.0 FLXMAT MANUFACTURE ACTIVITIES ...................................................................................4


4.1 PRE-EXECUTION ACTIVITES .................................................................................................................................................... 4 4.2 SITE ESTABLISHMENT.................................................................................................................................................................. 5 4.3 FLXMAT ASSEMBLY ....................................................................................................................................................................... 5 4.4 FLXMAT CASTING .......................................................................................................................................................................... 7 4.5 FLXMAT STORAGE AND HANDLING ................................................................................................................................... 8 4.6 ONSITE SAFETY REQUIREMENTS .......................................................................................................................................... 8

5.0 FLXMAT QA/QC ACTIVITIES.....................................................................................................8


5.1 FLXMAT QUALITY PROCEDURE ............................................................................................................................................. 8 5.2 FLXMAT CONCRETE TESTING................................................................................................................................................. 9 5.3 FLXMAT MARKING PROCEDURE ........................................................................................................................................... 9

6.0 INSPECTION AND REPAIR PROCEDURE ............................................................................ 10 7.0 FLXMAT DELIVERABLES ......................................................................................................... 10

Page:1

Execution Plan
1.0 INTRODUCTION The purpose of this document is to provide International Grout Operations with a suitable procedure to cover all necessary standards, specifications and methodologies required to successfully manufacture FLXMAT (pre-cast concrete mattress) to client specification. 2.0 REFERENCES 2.1 APPLICABLE CODES AND STANDARDS FLXMAT may be used to provide support or stabilisation to the subsea pipelines or other locations or instances described in the project specific scope of work. The necessary standards to be used in conjunction with the fabrication of the mattresses are given below: Code or Standard BS 1881 Pt 108 Title Methods for Testing Concrete Method of Making Test Cubes from Fresh Concrete Methods for Testing Concrete Method of Normal Curing of Test Specimens (20C Method) Methods for Testing Concrete Method for Determination of the Compressive Strength of Concrete Cubes Specification for Sulphate Resisting Portland Cement Methods for Specifying concrete including Ready Mixed Concrete Specification for Concrete Aggregates Test Method for Compressive Strength of Cylindrical Concrete Specimens Specification for Portland Cement Remark Followed by CONMIX LTD

BS 1881 Pt 111

Followed by CONMIX LTD

BS 1881 Pt 116 BS 4027 BS 5328 ASTM C33 ASTM C39 ASTM C150

Followed by CONMIX LTD Followed by CONMIX LTD Followed by CONMIX LTD Followed by CONMIX LTD Followed by CONMIX LTD Followed by CONMIX LTD

Page:2

Execution Plan
2.2 INTERNAL QA/QC DOCUMENTS Quality Assurance is overseen on site by an experienced International Grout Operations representative throughout the duration of the project. The Supervisor will ensure the correct Quality Checks have been made to each individual mattress guaranteeing the final product matches client request stated within the purchase agreement. IGO Documentation IGO DPR IGO ITP Description Daily Progress Report Inspection Test Plan Project Specific QR1 Quality Report 1 (Assembly checklist) QR2 Quality Report 2 (Casting checklist) Remark Daily event recordings onsite

IGO QAQC Plan

2.3 PROJECT SPECIFIC ENGINEERING DOCUMENTS FLXMAT Engineering is conducted in house using International Grout Operations Engineers. Mattress design and Engineering is always complete and agreed with client prior to construction commencement. The following documentation refers to client requested specific engineering requirements. IGO Documentation FLXMAT Construction Drawings - 0029-05-2010BDWG-071110-01REVA (No rubber) - 0029-05-2010BDWG-071110-01REVC (Inc rubber) IGO Lift Rope Verification FLX LIFT Description Remark Construction does not commence until client has approved final design. See ITP for more details

Approved FLXMAT drawing for construction

Calculation to verify lifting point conform to DNV Rules for Planning and Execution of Marine Operations (1996) Part 2 Ch 5/6

2.4 EXTERNAL CERTIFICATION AND DOCUMENTATION FLXMAT is made from 3 main components (HDPE Mould, PP Rope and Concrete). Rope Mill Test Certification is very important so that International Grout Operations Engineers can verify the correct rope has been used according to DNV Pt2, Ch5. Polypropylene Rope is purchased specifically for each project from an approved vendor. Similarly, concrete is purchased and delivered onsite by preferred supplier. Delivery dockets are collect by the supervisor and recorded. Concrete compressive strength tests are conducted at vendors laboratory. Final results from laboratory tests are sent to International Grout Operations and filled accordingly. The following summarises relevant external documents

Page:3

Execution Plan
Document Polypropylene Mill Test Certificate Description Certificate that proves a specific rope diameter Minimum Breaking Load (MBL) 1 page document that includes all relevant properties including strength, type of cement, slump aggregate size etc.. Delivery receipt to confirm grade and volume of concrete entering site. A test conducted whereby sampled cylinders are cast and crushed at certain period of curing. Remark Required to ensure FLXMAT lifting rope conform to DNV Pt2, Ch5 Mix design is required to be pre-approved by client prior to commencement of FLXMAT casting.

Concrete Mix Design

Concrete Delivery Dockets Compressive Strength Tests 3.0 SCOPE OF WORKS

See Section 2.1 for applicable codes and standards for testing.

The following table represents the physical requirements for each type of FLXMAT to be constructed. FLXMAT Qty 6x4x0.5m 5x3x0.3m 30 23 End/Side Lift END SIDE Long. Rope 22mm 16mm Lat. Rope 16mm 16mm Concrete Mix C13DNS C13DNS Drawing Ref 0029-05-2010BDWG-071110-01REVA 0029-05-2010BDWG-071110-01REVC

4.0 FLXMAT MANUFACTURE ACTIVITIES 4.1 PRE-EXECUTION ACTIVITES Prior to the execution program the final design and price is agreed upon and a purchase order is received by International Grout Operations outlining a date for completion or mattress delivery. The project manager will then organise freight of components (if necessary) schedule a starting date. An experienced supervisor is nominated and sent to location for site establishment. Work will continue to finalise all relevant documentation necessary to commence work according to International Grout Operations quality procedure.

Page:4

Execution Plan
4.2 SITE ESTABLISHMENT Upon the supervisor arriving to site a project brief is given from the project manager outlining the scope of works. All approved documentation is given to the supervisor in order to commence the fabrication according to this Execution Plan. The supervisor will firstly check all stock numbers of shells, clips and rope to ensure there are enough quantities of each to complete the order. If the quantities are incorrect the Supervisor will alert the Project Manager immediately to rectify the situation. The supervisor should have the following items in mind when initially setting up site. Suitable area for FLXMAT Assembly o Select shaded or enclosed area if possible (avoids heat exhaustion) o Select high ground is possible (avoids potential flooding, which is uncomfortable to staff) o Enable forklift entrance/exit if possible (reduces heavy man handling of objects) Suitable area for FLXMAT Casting o Fall of land when considering flooding (water must run away from work area) o Monitor unsettled dust during windy conditions (risk of eye injury to staff) o Avoid any rocky outcrop or remove if possible (reduces the risk of trip hazards) o Sufficient room for concrete trucks entering/exiting site (traffic management and safety) 4.3 FLXMAT ASSEMBLY Following points refer to assembling each mattress up until casting.

1. FLXMAT shells are laid out and clipped together either on ground level or on specially built clipping tables.

2. The bottom half of the mattress is clipped together until the length and width match that of the construction drawing.

Page:5

Execution Plan

3. Lateral and longitudinal ropes are pre-cut to determined length as noted on the construction drawing. 4. Lateral and longitudinal ropes are installed throughout the bottom half of the clipped mattress according the roping detail shown on construction drawing.

5. Lifting ropes are set to designed length as per construction drawing. Perimeter top shells are fastened first in order to contain rope lattice. 6. Rope ends are terminated using an open splice which should always be positioned toward the centre of the mattress and centre of shell. If design includes edge lift ropes then these should be installed as per instruction noted on mattress construction drawing.

7. Once all longitudinal and lateral ropes are tight remaining central blocks are clipped together to complete the mattress. Shells must be positioned carefully to locate each clips top half ensuring a positive connection.

8. The mattress is then lifted and relocated to the casting area via folk lift or a team of men. The mattress is carefully positioned on polythene sheet. The newly laid mattress is inspected and undergoes QR1 (Quality Record 1). QR1 is a set of quality checks required to be carried out prior to casting each mattress. On approval of QR1 the assembled mattress is clearly marked according to Section 5.4.

Page:6

Execution Plan
4.4 FLXMAT CASTING 1. Concrete is ordered by Supervisor ensuring the correct mix design is conveyed to the nominated vendor. The quantity is calculated based on the number of empty mattresses anticipated to be cast. 2. The concreting team prepare the initial casting location with shovels, trowels, vibrators, wheelbarrows, shadow boards and buckets. 3. The concrete truck is directed to drive alongside the assembled mattresses with chute full extended to aid filling distant blocks. The shadow boards mask all areas not requiring concrete guiding flow directly into each block.

4. Each mattress block is vibrated until full and no additional settlement is noticed. 5. Shadow boards are continually relocated as the process moves forward allowing the finishing team to trowel off the newly filled mattress and wash down any excess concrete. Lifting rope shall be washed free of any concrete spillage. 6. The mattress should be allowed to cure for a minimum of 3 days prior to lifting or confirmation of min. 14 MPa strength.

Page:7

Execution Plan
4.5 FLXMAT STORAGE AND HANDLING 1. Mattresses are only lifted with a suitable lifting frame of known capacity. Prior to lifting the supervisor will check with International Grout Operations Engineering that nominated frame and rigging is suitable to lift cured mattresses. 4.6 ONSITE SAFETY REQUIREMENTS All personnel shall attend any required site induction program to become familiar with the site and client method of operation. Personnel shall comply with all client rules and regulations. Company equipment includes a comprehensive first aid kit. Personnel will be briefed during the initial site induction on the hazards of manufacturing FLXMAT and handling cement products. The IGO supervisor will be responsible for site safety and conduct regular toolbox meetings with all personnel The following PPE (Personal Protective Equipment) is required for the 3 Manufacturing activities outlined above. Manufacturing Activity FLXMAT Assembly FLXMAT Casting FLXMAT Handling Minimum PPE Requirement Covered steel capped boots, coveralls and sun protection. Covered steel capped boots, eye protection, coveralls, gloves and sun protection and gloves Covered steel capped boots, eye protection, coveralls, gloves and sun protection, gloves and hardhat Optional Gloves Hardhat

5.0 FLXMAT QA/QC ACTIVITIES 5.1 FLXMAT QUALITY PROCEDURE Prior to commencement of manufacturing (PRE-EXECUTION) the following documentation must be approved by client. Inspection Test Plan Mattress Construction Drawing Lift Rope Verification Execution Plan Rope Certification Concrete mix design

Page:8

Execution Plan
During assembly and casting activities the quality of FLXMAT is built around the ongoing surveillance of the below documents. Project activities are monitored by International Grout Operations and/or Client depending on the rank of the inspection surveillance code listed within the approved ITP. QR1 (Quality Record 1) QR2 (Quality Record 2) Daily Progress Report (DPR) Concrete delivery docket Concrete Compressive Strength Results As-Built weight records

In summary to maintain an organised quality program the following chart describes the simple process. Approve and file PREEXECUTION DOCUMENTS APPROVED WORKING Result QUALITY PRODUCT

ITP
ASSEMBLY AND CASTING DOCUMENTS Follow Surveillance Codes 5.2 FLXMAT CONCRETE TESTING

Concrete vendor will take 12No. test cubes each day from random trucks delivered to casting yard (6No. cubes are allocated for each 7 day and 28 day tests respectively). All test cube samples are taken at the batching plant and stored in the dedicated laboratory where all testing is performed. 5.3 FLXMAT MARKING PROCEDURE Each precast concrete mattress shall be permanently marked with the following data: Individual Serial Number Contract Number Weight in Air

Page:9

Execution Plan
6.0 INSPECTION AND REPAIR PROCEDURE During assembly of the mattresses all shells and clips are inspected for faults. If a shell has any cracks or is deficient they are immediately discarded, and similarly clips are discarded if they are deficient. Any clips that are not holding shells together satisfactorily are reinforced with screws. After casting all mattresses are inspected by the International Grout Operations site supervisor and the inspection details are recorded within QR1. The mattresses are checked for any casting deficiencies that may compromise integrity. If after curing the mattress integrity is found to be affected or faults exist that impinge safe handling or risk mattress longevity, it will be discarded immediately. 7.0 FLXMAT DELIVERABLES The following documents make up and complete the Manufacturer Record Book (MBR) Manufacturer Record Book 1.0 FLXMAT Execution Plan 2.0 FLXMAT QA/QC Records 2.1 Signed ITP 2.2 Compiled QR1 (Quality Report 1) 2.3 Compiled QR2 (Quality Report 2) 2.4 Concrete Delivery Dockets 2.5 Concrete Compressive Strength Test Results 2.6 As-Built Weight Records 2.7 Onsite Daily Progress Reports (DPR) 3.0 FLXMAT Engineering 3.1 Concrete Mix Design 3.2 Mattress Construction Drawings 3.3 Lift Rope Verification 4.0 FLXMAT Rigging and Installation Procedure 5.0 FLXMAT Brochure

Page:10

MATTRESS LIFTING ROPE VERIFICATION FLX-ENG-LIFT


Client: Project: Project Number: Date: SPEC Management LLC 53No. 6x4x0.3m Concrete Mats 0029-05-2010B 7/11/2010

Introduction: The following calculations assess the mattress rope MBL for offshore lifting and are completed in accordance with DNV Rules for Planning and Execution of Marine Operations (1996) - Part 5&6 Variables: Load Factor [f] Consequence Factor [c] Splicing/Bending Factor [r] Wear Factor [w] Material Factor [m] Maximum Breaking Load [MBLActual] Remark Assume 1.3 Assumed 1.3 whereby sling failure would not incur a total loss Assumed 1.0 when splice consumed in concrete block Assume 1.0 Assume 3.0 for fibrous rope Actual Maximum Breaking Load of the rope supplied

Methodology: The minimum required MBL is calculated by the following: MBL required = Maximum Dynamic Rope Load x Nominal Safety Factor Maximum Dynamic Rope Load is back calculated from rope properties and lift geometry Dynamic load = (Mattress mass [MT] x DAF x Skew load) Nominal Safety Factor [st] - st = c . r . w . m . f
Finally for the lifting rope to be safe the following equation must be satisfied

Factor of Safety [FOS] MBLSpecified / MBLRequired Calculation:


PRE-PROCESSOR Mattress Properties Shell type [T1 or T2] Mattress Width [MW] Mattress Length [ML] Mattress Height [MH] Concrete Density [c] Concrete Grade (Min) T2 4m 6m 300 mm 3 2400 kg/m 40 MPa Mattress Particulars Block volume [Vb] Block mass [Mb] Total mattress volume (VT) Total Mass of Mattress [MT] Total Submerged Mass [MSUB] Lift Rope Particulars Nominal Safety Factor Lift Rope Properties Type of Rope Diameter of Rope [Dr] Angle of Sling [s] Consequence Factor [c] Splicing/Bending Factor [r] Wear Factor [w] Material Factor [m] Load Factor [f] Breaking Load [MBLActual] Lifting Properties Dynamic Amplification Factor [DAF] 2.00 Polypropylene 22 mm 20 1.3 1.0 1.0 3.0 1.3 6.8 Te Lifting Particulars Dynamic load Required MBL FOS (Over Designed by-) 23.13 t 3.66 t 1.856 PASS 5.070
3 0.047 m

POST-PROCESSOR

113 kg 4.53 m 10.87 t 6.23 t


3

0 Revision

7/11/2010

Date

Issued for Approval Issue

JD By

Checked

Approved

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 18 of 23

Attachment 3: GERIMAL SPECIFICATION

Halani International Ltd.


DSV Gerimal
PRINCIPAL PARTICULARS Registry : Kingstown St. Vincent Call Sign : J8B3528 Official No. : 10001 Year Built : 1981-Refurbished in Aug 2007 Class : American Bureau of Shipping Notation : A1, AMS, DPS-2 Type : Diving Support /accommodation 76 Pax Vessel Class No. : 8125016 IMO No. : 7932240 Hull No. : 837 Flag : St. Vincent & Grenadines, Kingstowns

DIMENSION Length Overall : 76.14 m Moulded Breadth : 16.4 m Depth Moulded : 4.90m Draftc : 4.00 m GRT : 2008 Mt NRT : 602 Mt Deadweight : 954 Mt DISCHARGE RATES 3 Fuel Oil : 97m /hour Fresh Water : Not known Mud : delete no mud tanks

PERFORMANCE Maximum speed :8.0 kn Economical speed : 7.0 ln Type of fuel :Marine Gas Oil CARGO CAPACITIES 2 Deck Strength : 10 t/m 2 Clear Deck Area : 650 m 3 Fuel Oil : 502.4M 3 Fresh Water : 794.0 M 3 Ballast/Drill Water : 473.9 M 3 Freezer : 10 m 3 Chiller : 9.5 m Mud : Delete DP2 DYNAMIC POSITIONING SYSTEM DP System : KPOS DP 21, Dynamic Positioning System KPOS-2 3 Gyro compass 2Wind Sensor 3MRU 2DGPS 2UPS 1 LW TAUTWIRE MK15 1 HIPAP 450 2K-POS OS 2 JOY-OT C WING - OT PROPULSION SYSTEM Main Engine : 2 x Guleco DC Motors Main Generator : 5 x 900 Kw, 600V, 60Hz Emergency Genset : Propeller : 2 x 5Blade, Fixed pitch 102 in Kort Nozzle Bow Thruster : 4 nos. Fwd: 2nos:- 1 x GEI 752 Kamewa

NAVIGATIONAL /COMMUNICATION EQUIPMENT GMDSS SSB : 1 x Sailor HT 4500MF/HF VHF DSC : 2 x Sailor RT2058 Inmarsat -C : 2 x Sailor H2095C transceivers Satellite Comms : FLEET 77 Tel 00873 761155141 Fax 00873 761155142 Satellite EPIRB : 1 X McMURDO E-3 SART : 2McMURDO RT9-3 VHF Radio : 3 x Sailor Compact Rt2048 Portable VHF Radio : 6 x Motorola GP 340 : 3 x ICOM IC GM 1500E Navtex Receiver : 1 x JMC NT-900 X-Band Radar : Furuno FR 2115 Echo Sounder : Koden CVS 118 Mk II Gyrocompass : 3 x Sperry mk 37 Weather Fax : 1 x Furuno Fax-207,8 delete not fitted Speed Log : Delete, none fitted Magnetic Compass : Saura keiki AIS : JRC KHS 182

Ulstein Transverse T Thruster, TT 1300, 500KW. electric


drive, 485kW Stern 2nos:-2 x Kamewa Ulstein Transverse, TT 1300, 500KW FIRE FIGHITING EQUIPMENT Internal 3 Fire Pump : 14M (3800USG Per/M) 3 Emer. Fire Pump : 24 M (6400USG Per/M) Fixed System in E/R: C02 Firemain : 2 Fire Detection Sys. : Heat & Smoke detectors Firemans Outfit : 4 nos Fire Blankets : 2 nos Fire Axe : 2 nos

ACCOMMODATIONS Berths Hospital : 76Berth : 1 bed complete

Particulars given are entirely without warranty as to correctness and interested parties must satisfy themselves by inspection of the vessel

Halani International Ltd..


DSV Gerimal

DECK EQUIPMENT Windlass : IP 66 / IM 10001 Anchor : 2 x 1.18t Anchor Chain : 9 shackles each side Main Crane : 40t @ 5.5 m 18t @ 9.0m 6.5t @ 20.0m 4.7t @ 24.0m Auxiliary Crane : 0.5t Gangway : 1 Nos

LIFE SAVING APPLIANCE Search Lights : 3 nos Floodlights : 2 x overboard Liferafts : 4 x 45 persons 6 x 25 persons Lifebuoys : 12Ring Buoys with smoke floats and signal lights Life jackets : 150 Ncs Rescue boat : 1 x Watercraft R-5 Air Breathing App : 4 nos EEBD : 6 nos Parachute Distress : 12 Smoke Signal :6

Particulars given are entirely without warranty as to correctness and interested parties must satisfy themselves by inspection of the vessel

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 19 of 23

Attachment 4: CRANE CHART

Crane Boom Lifting Capacity


Working radius (m) Boom length (m)

Unit: metric ton

Counterweight: 53.0 t, Carbody weight: 10.0 t


15.2 18.3 21.3 24.4 27.4 30.5 33.5 36.6 39.6 42.7 45.7 48.8
Boom length (m) Working radius (m)

4.5 5.0 6.0 7.0 8.0 9.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.0 34.0 36.0 38.0 40.0 42.0 44.0 Reeves

4.5 m/135.0 131.1 5.1 m/128.4 5.6 m/117.2 110.1 109.6 6.1 m/107.8 6.7 m/95.1 110.4 91.1 89.3 7.2 m/84.2 7.7 m/75.3 94.8 93.3 95.1 74.6 72.4 8.2 m/67.8 8.8 m/61.7 77.4 75.9 79.9 79.1 79.5 61.5 60.0 64.9 62.5 67.2 66.0 68.8 68.5 67.7 55.0 53.6 58.8 58.3 57.4 56.5 59.0 59.0 58.4 44.9 44.1 45.2 45.1 45.4 45.2 45.7 45.6 44.3 36.3 36.2 36.8 36.6 36.5 36.5 37.1 37.0 33.5 30.2 30.1 14.8 m/29.3 30.8 30.6 30.0 31.0 30.5 30.4 25.8 25.7 17.5 m/24.8 26.4 26.2 26.6 26.1 26.0 22.4 22.3 23.0 22.8 21.7 22.7 22.6 19.7 19.6 20.1 m/21.3 19.9 20.1 20.0 19.9 17.5 17.4 22.8 m/18.5 18.0 17.9 17.7 15.7 15.6 25.4 m/16.0 16.1 16.0 14.2 14.1 14.2 14.5 12.9 12.8 28.1 m/14.1 13.2 11.8 11.7 30.7 m/12.5 10.8 33.3 m/10.9 9.7

9.3 m/56.3 52.2 43.0 36.1 30.0 25.6 22.2 19.5 17.3 15.5 13.9 12.7 11.5 10.6 9.8 8.9 38.6 m/8.6 5

10

10

9.8 m/51.8 50.9 10.4 m/47.8 41.0 42.0 34.7 35.6 29.8 29.9 25.3 25.4 21.9 22.0 19.2 19.3 17.0 17.1 15.2 15.3 13.6 13.8 12.3 12.5 11.2 11.4 10.3 10.4 9.4 9.6 8.7 8.8 8.0 8.1 41.2 m/7.5 7.4 43.9 m/6.5 4 4

4.5 5.0 6.0 7.0 8.0 9.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.0 34.0 36.0 38.0 40.0 42.0 44.0 Reeves

Working radius (m)

Boom length (m)

51.8

54.9

57.9

61.0

64.0

67.1

70.1

73.2

76.2

Boom length (m)

Working radius (m)

10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.0 34.0 36.0 38.0 40.0 42.0 44.0 46.0 48.0 50.0 52.0 54.0 56.0 58.0 60.0 Reeves

10.9 m/44.2 11.4 m/40.1 11.9m/38.4 40.0 39.1 38.2 12.5 m/35.8 13.0 m/33.4 13.5 m/26.7 31.7 30.9 26.7 14.1 m/26.7 14.6 m/24.4 15.1 m/20.4 33.9 33.2 32.5 25.7 22.7 19.4 27.4 26.7 26.3 29.3 28.7 28.1 22.5 20.6 17.5 24.0 23.4 23.0 25.2 25.1 24.6 19.9 18.8 15.8 21.2 20.7 20.4 21.7 21.6 21.5 17.7 17.1 14.3 18.6 18.4 18.1 19.0 18.9 18.8 15.8 15.4 13.0 16.4 16.2 16.2 16.8 16.7 16.6 14.2 13.8 11.8 14.6 14.4 14.4 15.0 14.9 14.7 12.7 12.4 10.7 13.1 12.9 12.8 13.5 13.4 13.2 11.4 11.2 9.7 11.7 11.6 11.5 12.2 12.1 11.9 10.2 10.0 8.8 10.6 10.4 10.4 11.1 10.9 10.8 9.2 9.1 8.0 9.6 9.4 9.4 10.1 10.0 9.8 8.4 8.2 7.2 8.8 8.6 8.5 9.2 9.1 8.9 7.6 7.4 6.5 8.0 7.8 7.8 8.5 8.4 8.2 6.9 6.7 5.8 7.3 7.1 7.1 7.8 7.7 7.5 6.3 6.1 5.2 6.7 6.5 6.5 7.2 7.1 6.9 5.7 5.5 4.6 6.2 6.0 5.9 6.7 6.5 6.4 5.2 4.9 4.0 5.7 5.4 5.3 5.9 6.0 5.9 46.5 m/5.7 4.7 4.4 3.5 5.2 4.9 4.9 5.3 5.4 49.2 m/4.8 4.2 4.0 2.9 4.7 4.5 4.4 4.7 51.8 m/4.1 3.8 3.6 2.4 4.2 4.1 4.0 3.4 3.2 3.6 3.6 3.5 54.4 m/3.4 3.0 2.8 3.0 3.1 57.1m/2.8 2.5 2.4 2.6 59.7 m/2.2 2.1 4 3 3 3 3 2 2 2 2

10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.0 34.0 36.0 38.0 40.0 42.0 44.0 46.0 48.0 50.0 52.0 54.0 56.0 58.0 60.0 Reeves

Note: Ratings according to EN13000. Ratings shown in are determined by the strength of the boom or other structural components. Refer to notes P12.

13

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 20 of 23

Attachment 5: DIVING PROCEDURE

SAT DHRUV 12 MEN SATURATION DIVING SYSTEM SPECIFICATION

TABLEOFCONTENTS

PAGE

General Description Summary of the Module Inventory Diving System Components 1. Three Men Diving Bell 2. Single Lock Decompression Chamber (4-man) DDC-013 3. Single Lock Decompression Chamber (6-man) DDC-021 4. Single Lock Hyperbaric rescue Chamber (12-man) HRC 5. Single Lock TUP Chamber with four spool connection doors 6. Environmental Control System (in Life Support Equipment Container) 7. Hot Water System-electric (in Life Support Equipment Container) 8. Saturation Control Container 9. Bell Dive Control Container 10. Electrical Distribution Panel (in Sat/Bell Container) 11. HRC Trunk 12. Potable Water System (in Life Support Equipment Container) 13. Umbilical Module 14. Spool Piece between Chambers (DDC013 & DDC 021) 15. Spool Piece between TUP & Chamber (DDC 013) 16. Spool Piece between HRC & TUP 17. Spool Piece TUP to Diving Bell mating clamp 18. Sanitary System 19. A Frame Assembly 20. Clump Weight System 21. Hydraulic Bell Winch 22. Newly build Hydraulic Power Pack Module 23. Main Bell Umbilical Power Sheave 24. Workshop/Spares Container 25. HRC Control Van 26. Certification

3 3 4 4 5 6 6 7 8 8 9 9 9 9 10 10 10 10 10 10 11 11 11 11 11 12 12 12 12

SAT DHRUV 12 MEN Saturation Diving System Specification

General Description The saturation diving system is of modular construction, meaning that the major components of the diving system are built into individual crash frames which will also allow the system to be configured in different configurations to make maximum use of the space available on the barge or proposed dive ship. The saturation diving complex and associated equipment is capable of supporting a 12 man diving team in 1 x 4 plus, 1 x 3 man bunk &12 sitting HRC & 1 x 6 men chambers to a maximum working depth of 200 meters. The design and certification for the diving system will be for a maximum design pressure of 200 meters. The diving bell will be equipped for three divers. It will be used for saturation mode only. The bell has one side mating position. The bell will be handled by a simple A Frame assembly, with two hydraulic rams and the trolley will bring the bell in to the side mating position. For deployment, the bell will be trolley out and will be hoisted in to the catcher deployment system, the A Frame will be boomed out to the launch position. The handling system for the bell will also incorporate a hydraulic bell winch and a Hydraulic driven clump weight winch. The hydraulic main bell winch will be the primary means of recovery and deployment. This will use the hydraulic motor as the primary means of operating the winch and the air motor will be the secondary means of operating the winch and the clump weight winch will act as another means of recovery. The operation of the hydraulic handling system and winches will be from the hydraulic control consul, which is situated on top of the living chamber (DDC 013) Skid package. Summary of the Module Inventory 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. Single Lock Decompression Chamber (4-man) DDC 013 6 Man Living Come Out Chamber (DDC023) Diving Bell (3 man) 12 x Man Hyperbaric Rescue Chamber with (1 x 3 bunk) living chamber (HRC) TUP (Transfers under pressure) with spool four doors for chambers connection. Four Environmental Control System (in Life Support Equipment Container) Two Hot Water System-electric (in Life Support Equipment Container) Saturation Control container with Potable Water System hot & cold water supply to all chambers. Bell Dive Control Container with client office. Bell Umbilical Basket C/W 250m new Main bell umbilical Electrical Distribution Panel (in Sat / Bell dive Container) HRC Trunk on TUP Bell mating trunk on TUP. DDC-013 mating trunk on TUP. DDC-021 mating trunk on DDC-013. Sanitary System A Frame Assembly with bell trolley assembly. Clump Weight System Hydraulic Bell Winch
3

SAT DHRUV 12 MEN Saturation Diving System Specification

20. 21. 22. 23. 24. 25. 26.

Hydraulic Power Pack Module Main Bell Umbilical hyd. Power Sheave Hydraulic clump weight winch. Workshop/Store Spares container Secondary Divers Hot water unit diesel powered HRC control unit with chillier unite Life Support Equipment Container Transit frame

Diving System Components

1. Three Men Diving Bell The diving bell will be equipped for three divers. It will be used for saturation mode only. The bell has one side mating position. The bell will be handled by a simple A Frame assembly with two hydraulic rams and the trolley will bring the bell in to the side mating position.

SAT DHRUV 12 MEN Saturation Diving System Specification

2. Single Lock Decompression Chamber (4-man) DDC-013 Four-man single lock living decompression chamber with TUP Trunk, having 4 bunks, Medical lock and Man way to living decompression chamber DDC-021. This chamber was built in 1977 by Aqua Logistic and has an internal diameter of 2.2-mtr diameters, inside length 4.2 metres, internal volume 16,9 M3 and safe working depth-200 metres. The Design code BS1515 Part1-1965. Certifing authority Lloyds. However the chamber has been fully refurbished and recertified by ABS in March 2009 along with the complete spread. The chamber is mounted in a heavy-duty transit frame, which forms part of the base for the A-frame bell deployment system, winch package and hydraulic power pack. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Pipe work and valves (JIC & NPT) Electrical system 24V. DC One internal conditioning system Four C02 scrubbers One sound power phone One speaker bull horn Four call button Four diver personal communication Four hyperbaric bunk lights Two hyperbaric chamber lights One caisson gauge One temperature and humidity gauge Four bunks Chamber aluminium flooring Four overboard dump mask connection points, two manifold blocks and one tescom back pressure regulator One temperature sensor Medical lock with interlock One toilet system One shower system One sinks

SAT DHRUV 12 MEN Saturation Diving System Specification

3. Single Lock Decompression Chamber (6-man) DDC-021 Six-man single lock living chamber with having 6 bunks, Medical lock and Man way to living decompression chamber DDC-013.This chamber was built 1977 by Seafoth and has an internal diameter of 2.2-mtr diameters, inside length 7.6 metres, internal volume 36,8 M3 and safe working depth-200 metres. The Design code BS1515 Part1-1965. Certifing authority Lloyds. However the chamber has been fully refurbished and recertified by ABS in March 2009 along with the complete spread. The chamber is mounted in a heavy duty transit frame. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Pipe work and valves (NPT) Electrical system 24V. DC Two internal conditioning system Six C02 scrubbers One sound power phone One speaker bull horn Six call button Six diver personal communication Six hyperbaric bunk lights Four hyperbaric chamber lights One caisson gauge One temperature and humidity gauge Six bunks Chamber aluminium flooring Six overboard dump mask connection points, two manifold block and one Tescom back pressure regulator One temperature sensor Medical lock with interlock One toilet system One shower system One sinks

4. Single Lock Hyperbaric rescue Chamber (12-man) HRC 1 x 3 man bunk &12 sitting HRC chambers to a maximum working depth of 300 meters. Three-man single lock living chamber with having three door for mating clamp and 3 bunks, Medical lock and Man way to TUP. This chamber was built in 1982 by Aqua Logistic international ltd. and has an internal diameter of 2.2-mtr diameters, inside length 4.6 metres, internal volume 16,8 M3 and safe working depth-300mtrs. The Design code BS1515 Part1-1965.Certifing authority Lloyds. However the chamber has been fully refurbished and re-certified by ABS in March 2009 along with the complete spread. The chamber is mounted in a heavy-duty transit frame and launching skid with HRC Bottom four wheels which allow HRC to slid itself into water. 1. 2. 3. 4. 5. Pipe work and valves (JIC & NPT) Electrical system 24V. DC One internal conditioning system Four C02 scrubbers One sound power phone
6

SAT DHRUV 12 MEN Saturation Diving System Specification

6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20.

One speaker bull horn Three call button Three diver personal communication Three hyperbaric bunk lights Two hyperbaric chamber lights One caisson gauge One temperature and humidity gauge Three bunks Chamber aluminium flooring Three overboard dump mask connection points, two manifold blocks and one Tescom back pressure regulator One temperature sensor Medical lock with interlock One toilet system One shower system One sink

5. Single Lock TUP Chamber with four spool connection doors. Single lock TUP chamber with having four spool connection doors, Man way to living decompression chamber DDC-013, Man way to HRC chamber, Man way trunk to Diving bell and top door closed & blanked from out side. This chamber was built by Seafoth and has an internal diameter 1.7mtr, inside height 1.9 metre, internal volume 5.6 M3 and safe working depth-200 metres. The Design code BS1515 Part1-1965.Certifing authority Lloyds. However the chamber has been fully refurbished and certified by ABS in March 2009 along with the complete spread. The chamber is mounted in a heavy-duty transit frame. Which forms part of the base for the A-frame bell deployment system, winch package and hydraulic power pack.
SAT DHRUV 12 MEN Saturation Diving System Specification

1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.

Pipe work and valves (JIC & NPT) Electrical system 24V. DC One internal conditioning system One C02 scrubbers One sound power phone One speaker bull horn One call button Two hyperbaric chamber lights One caisson gauge Chamber aluminium flooring One toilet system One shower system One sink

6. Environmental Control System (in Life Support Equipment Container) This consists of four individual Kinergetic CMU units. The four units will be stacked in the life support equipment container complete with reservoir receivers mounted on the wall. These units will be configured as unit 1 and 2 as the primary operational units and unit 3 to be used as a stand-by unit. The system will maintain complete automatic control of the temperature and humidity in the chambers and will also remove CO2 produced by the divers in the chamber. The system provides control of heating, cooling and dehumidification of the divers Breathing gases. The pipe work from the reservoirs to the penetrate plates in the container will be hard plumbed with a series of pipe work and valves to interconnect all the CMU units. All the internal habitat control units (HCU) in the chamber are connected to the penetrator plate by suitable deck hoses.

7. Hot Water System-electric (in Life Support Equipment Container) A single boiler/heater tank is supplied using a single pressure vessel with over pressurization devices. This heater unit will be electrically powered and capable of heating seawater and freshwater with a flow of 10 gpm @ 4 bar inlet water pressure, the unit should have a temperature range of 30c to 70c with +/- 2c control. A grundfoss pump is incorporated within the skid to boost this hot water supply to the divers at 27 bar. The hot water incorporate the following: 1. 2. 3. 4. 5. 6. 7. Inline water filtration. Electrical isolation control. Earth leakage trip system. Low flow alarm. High temperature alarm. Pump motor start/stop delay. Digital temperature control and display.

SAT DHRUV 12 MEN Saturation Diving System Specification

8. Saturation Control Container The saturation control room has the following services included in the system: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Depth monitoring system DDCs , HRC and Trunks. Pressurization and vent DDCs, HRC and Trunks. Bib control panel DDCs and HRC. CO2 and O2 analyzer panel DDCs and HRC. Calibration gas panel DDCs and HRC. O2 injection panel DDCs and HRC. Environment control panel DDCs. Temperature monitoring panel DDCs & HRC Communication control panel to all compartments Diver personnel communication system to all bunks in the chambers On line gas storage panel (distribution). Pressurization. Bibs. Treatment mix. One B/A hose line connection. Electric distribution Panel.

12. 13.

9. Bell Dive Control Container The bell control room shall have the following services included in the system: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Depth monitoring system internal, external. Depth monitoring system internal, diver 1 and 2. Depth monitoring system internal, trunk to TUP. Pressurization and vent of bell and trunk. On line (gas supply) monitoring for divers. CO2 and O2 analyzer panel for divers and bell. Gas calibration panel. Communication panel for bell and divers. On line mix gas distribution panel. One B/A hose line connection. Electric distribution panel and isolation panel for total bell system.

10. Electrical Distribution Panel (in Sat/Bell Container) Isolation control boxes will be situated in bell control container; all electrical services from the diving system are terminated at a breaker panel along side the main isolation panel and linked together. An earth leakage trip system is incorporated in the panel. 11. HRC Trunk A HRC Trunk is supplied. This is connected to the TUP. The clamp will be an Hingetype hand-operated clamp. All penetrations for the pressurization, vent and depth monitoring are fitted to the trunk.

SAT DHRUV 12 MEN Saturation Diving System Specification

12. Potable Water System (in Life Support Equipment Container) The potable water system supplies hot and cold water at 7 bars over the working pressure in continuous operation and consist of two systems including: Hot & Cold water tanks Gas Panel Temperature and Pressure Indicators 13. Umbilical Module A main bell umbilical is provided comprising of the following specification: 5 x Inch Pneumos 1 x Inch Hot Water Hose 1 x Inches Reclaim Hose 1 x Inch Divers Gas Hose 1 x Bell Blow Down 2 x Comms/TV & Power cables. Close mesh polythene monofilament over braid. An umbilical storage basket is provided. The storage basket will be of steel construction with four lifting lugs and a four point lifting sling. 14. Spool Piece between Chambers (DDC013 & DDC 021) A spool piece between the DDC-1 and DDC2 incorporates pressurization, vent and depth monitoring in the trunk. The other spool piece will connect the TUP & DDC013 living chamber. 15. Spool Piece between TUP & Chamber (DDC 013) A spool piece between the DDC-1 and TUP incorporate pressurization, vent and depth monitoring in the trunk. The other spool piece connects the TUP & HRC living chamber. 16. Spool Piece between HRC & TUP. A spool piece between the DDC-1 and HRC mating clamp incorporates pressurization, vent and depth monitoring in the trunk. The other spool piece will connect the TUP & BELL mating clamp. 17. Spool Piece TUP to Diving Bell mating clamp The spool piece between the diving bell mating clamp and TUP is positioned on the side man way on the TUP. This incorporate a hydraulically operated type clamp with safety interlock. This spool piece also equipped with: 1. Pressure and vent penetrator 2. Depth sensor line penetrator
SAT DHRUV 12 MEN Saturation Diving System Specification

10

18. Sanitary System The DDCs sanitary system has a connection to connect to the ships sanitary system via a holding tank with all necessary valves and safety devices situated on the main skids. 19. A Frame Assembly a) The A boom frame is constructed of 290 x 260 mm heavy-duty I beam steel and fabricated with ladder runs up the A Frame to assist with the maintenance and inspection of the unit. A main bell lift wire sheave is located under the top/centre section of the A frame and in association with this there are pulley and stop-end for use with the clump weight and clump weight wire. b) The A boom davit is powered by two hydraulic rams which move the bell over the ships side. 20. Clump Weight System A guide wire system is fitted to provide stability to the bell. This system also acts as a secondary means of recovery of the bell to the interface and a means of supporting the bell clear of the bottom. The system consists of: a) One hydraulic winch rated at 7 ton load / 13.6 ton pull b) 450 meters of 28mm spin resistant wire c) One clamp weight.

21. Hydraulic Bell Winch The winch itself is a hydraulic man riding winch and is situated over the TUP & Single lock living chamber upper skid. The winch has a spooling device for the wire rope to prevent any over-laying of wire. The pneumatic air motor with gearbox and chain drive will give twice the full load capacity to safely retrieve the bell in the event of electric power failure. Air auxiliary drives 10 tons at 6m/min. Air consumption 350 cfm at 80 psi. installation of the hydraulic system is geared to be of the shortest duration with all fittings of quick (Aero quip) disconnect type.

22. Newly build Hydraulic Power Pack Module The hydraulic power pack utilizes 2 x 50 KW (100 HP) 3 Phase electric motor. This power pack provides sufficient power to run the system. The power pack delivers hydraulic pressure to the bell winch, the main A-Frame rams, trolly ram,umb. Sheave and to clamp weight winch.

SAT DHRUV 12 MEN Saturation Diving System Specification

11

23. Main Bell Umbilical Power Sheave This consist of a 1.5 meter dia steel fabricated sheave to accommodate the main bell umbilical. The sheave is driven through Lucas type reduction gear box and driven by an independent hydraulic motor. This unit is mounted on a pedestal so it can be positioned along side the main bell umbilical and A Frame to deploy and recover the main bell umbilical with the bell movements. The controls for this power sheave are located with the bell handling system controls above the main DDC Package. 24. Workshop/Spares Container This will contain spares and tools for the saturation system. 25. HRC Control Van This unit is fitted with a decompression panel including depth gauges, O2 and CO2 Analyzers, communication system and a Habitat control unit. 26. Certification All documentation and certification is in accordance with the H.S.E. & IMCA. (Code of Practice on the Initial & Periodic Examination, Testing and Certification of Diving Plant & Equipment DO18).

SAT DHRUV 12 MEN Saturation Diving System Specification

12

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 21 of 23

Attachment 6: SURVEY QUALITY PLAN

Survey Quality Plan


Positioning Survey Services In Support of the Installation Pre-Lay Crossing Supports Proposed 24 Export Pipeline, FZ-A to Kharg Island
Foroozan Field Persian Gulf, Offshore Iran For SPEC Ship Management L.L.C Revision: 0 Project Date: December 2010 Prepared By Horizon Survey Company (FZC)
P.O. Box 68785 Sharjah International Airport Free Zone (SAIF Zone) Sharjah United Arab Emirates Tel: +971 6 557 3045 / Fax: +971 6 557 3047 enquiries@horizonsurvey.ae
HSC Project No.: HSC Document No.: CP-SPE-0566A CP-SPE-0566A - Survey Quality Plan - Rev 0

Project Information
Project : Client : Contract Reference No. : HSC Project No. : HSC Document No. : Positioning Survey Services. SPEC Ship Management L.L.C SPE/HOR/10/001 CP-SPE-0566A CP-SPE-0566A - Survey Quality Plan - Rev 0

Issued To: SPEC Ship Management L.L.C


For the Attention of : Address : Mr Afshin Parsaie SPEC Ship Management L.L.C Floor No.4, No. 54 2nd Street, Mirzayehshirazi St. Karimkhab Blv. Tehran Iran Tel : Fax : Email : +98 21 8892 2417 +98 21 8834 8030 Parsaie@spec-uae.com

Issued By: Horizon Survey Company (FZC)


Project Manager : Address : Hamid Ardalany Horizon Survey Company (FZC) P.O. Box 68785 Sharjah International Airport Free Zone (SAIF Zone) Sharjah United Arab Emirates Tel : Fax : Email : +971 6 557 3045 +971 6 557 3047 h.ardalany@horizonsurvey.ae

Page: i

CP-SPE-0566A - Survey Quality Plan - Rev 0

Horizon Survey (HSC) Revision Control


Revision No. 0 Description Issued for client comments Prepared By JB Checked By KB/VK Approved By AD Issue Date 27.12.2010

Survey Procedures Volume Description


Volume No. n/a Volume Title Survey Quality Plan Contents Project information, scope of work, detail of the methodologies, procedures and resources for the project.

Page: ii

CP-SPE-0566A - Survey Quality Plan - Rev 0

Table of Contents
Page 1. 1.1. 1.2. 1.3. 1.3.1. 1.4. 1.4.1. 1.5. 1.5.1. 1.5.2. 2. 2.1. 2.2. 2.2.1. 2.2.2. 2.2.3. 2.3. 2.3.1. 2.3.2. 2.4. 2.4.1. 2.4.2. 2.4.3. 2.4.4. 2.4.5. 2.4.6. 2.5. 2.6. 2.6.1. 2.7. 2.7.1. 2.7.2. 2.7.3. 2.7.4. 2.8. 2.9. 2.9.1. 2.9.2. 3. 3.1. 3.1.1. 3.1.2. 3.2. 3.3. 4. 5. 5.1. 5.2. 5.3. 5.4. INTRODUCTION Reference Documentation Scope of Work Client Supplied Information Crossing positions of the proposed Foroozan 24" FZ-A to Kharg export pipeline Crossing Support Locations Foroozan 24" FZ-A to Kharg Pipeline Crossing Support Locations Survey Line Plan Pre-Installation Survey As-Built Survey SURVEY AND REPORTING METHODOLOGIES Mobilisation Geodetic References, Datums and Tidal Reduction Geodetic References Vertical Datum Tidal Reduction Vessel Offsets, Horizontal and Height References Horizontal Reference Vertical Vessel Reference Field Operations Pre-Installation MBES Survey Surface Positioning Underwater Positioning Sector Scan Sonar As-Built MBES Survey Bathymetric Acquisition Real Time QC Monitoring Data Processing/Analysis and Reporting Daily Survey Logs Reporting Project Daily Reports Pre-Installation Reports Crossing Installation Reports Final Survey Report Report Delivery Schedule Demobilisation Project Demobilisation Project Backup QUALITY CONTROL Quality Policy and Objectives Quality Policy Quality Objectives Horizon Survey Organisation Standard QC Check List PROJECT DELIVERABLE CHECK LIST HEALTH, SAFETY AND ENVIRONMENT HSE Policy Environmental and Waste Management Policy Drug and Alcohol Abuse Policy Stop Work Policy 1 1 1 2 2 3 3 4 4 4 6 6 6 6 7 7 7 7 7 7 8 8 8 8 8 9 9 10 10 10 10 10 11 12 12 12 12 12 13 13 13 13 13 13 14 15 15 16 16 16

Page: iii

CP-SPE-0566A - Survey Quality Plan - Rev 0

List of Appendices
Page APPENDIX A EQUIPMENT LISTING & SPECIFICATIONS Survey Equipment APPENDIX B CLIENT SUPPLIED INFORMATION APPENDIX C SURVEY PARAMETERS, TIDES AND UNITS GPS Geodetic Parameters Project Geodetic Parameters Geodetic Computation Check Survey Units26 APPENDIX D SYSTEM VERIFICATIONS & CALIBRATIONS In-Port Verifications - Vessel Offset Measurements - Static DGPS Health Verification - Gyrocompass Alignment Calibration - Static USBL Calibration In Field Calibrations - Transit Fix Check - Sound Velocity Measurements - Dynamic USBL Calibration - MBES Calibration True/Grid Headings and Convergence Calculations - Area / Line is West of Central Meridian - Area / Line is East of Central Meridian APPENDIX E PROCESSING OUTLINES APPENDIX F HORIZON SURVEY ORGANIZATION CHART APPENDIX G QUALITY CONTROL APPENDIX H HORIZON SURVEY CONTACT LISTING 17 18 19 20 21 21 22 27 28 28 28 30 32 32 32 32 33 36 37 37 37 38 40 42 48

Page: iv

CP-SPE-0566A - Survey Quality Plan - Rev 0

List of Tables
Page Table 1: Personnel Responsibilities and SQP Awareness Table 2: Survey Sensors/Equipment Table 3: 24- Foroozan 24" FZ-A to Kharg - Pipeline Crossing Locations Table 4: Foroozan 24" FZ-A-Kharg Pipeline Crossing Support Locations Table 5: Survey Line Plan Table 6: Equipment Onboard DP 'Gerimal' Table 7: Pipeline Crossing Report Volumes (CP-SPE-0566A) Table 8: Report Delivery Schedule Table 9: CP-SPE-0566A - Deliverable Check List Table 10: GPS Geodetic Parameters Table 11: Project Geodetic Parameters Table 12: Geodetic Computation Check Table 13: Project Survey Units Table 14: Horizon Surveys Standard QC Check List Table 15: HSC Management Contact Details viii 1 2 3 4 6 11 12 14 21 21 22 26 47 49

List of Diagrams
Page Diagram 1: Survey Location Diagram 2: DGPS Verification Diagram, First Method Diagram 3: DGPS Verification Diagram, Second Method Diagram 4: DGPS Verification Diagram, Third Method Diagram 5: Gyro Calibration Diagram, First Method Diagram 6: Gyro Calibration Diagram, Second Method Diagram 7: Gyro Calibration Diagram, Third Method Diagram 8: Dynamic USBL Calibration, First Method, Stage 1 Diagram 9: Dynamic USBL Calibration, First Method, Stage 2 Diagram 10: Dynamic USBL Calibration, Second Method Diagram 11: Convergence Calculations 5 29 29 29 31 31 31 34 34 35 37

Page: v

CP-SPE-0566A - Survey Quality Plan - Rev 0

Abbreviations & Acronyms The following list of abbreviations and acronyms may be present within the document: CRP CTDS DA DGPS DSV GMT GPS HSC HSE IP L.A.T. LFP MBES ms m/s MSL NTS PC PM PDR ppm PPS pps ppt QC s SM SoW SPM SQP TBA TBC TM TP TVG USBL UTC UTM v/l VoS VRU Common Reference Point (Datum) Conductivity, Temperature, Depth and Salinity (to compute VoS) Data Acquisition (CODA DA System). Differential Global Positioning System Dive Support Vessel Greenwich Mean Time Global Positioning System Horizon Survey Company Health, Safety & Environment Intersection Point Lowest Astronomical Tide Landfall Point Multi Beam Echo Sounder Milli-second Metres per second Mean Sea Level Not To Scale Party Chief Project Manager Project Daily Report Parts per million Precise Positioning System Pulse per second Parts per thousand Quality Control Second Survey Manager Scope of Work Single Point Mooring System Survey Quality Plan To Be Announced To Be Confirmed Transverse Mercator Turning Point Time Variant Gain Ultra Short Base-line (underwater acoustic positioning system) Coordinated Universal Time Universal Transverse Mercator Survey Vessel Velocity of Sound in Seawater Vertical Reference Unit

Reference Colour Code The following reference colour coding may be used within this document: XXX XXX XXX Reference to an independent external document. Reference to another section or article within this document. Important Note / Caution

Page: vi

CP-SPE-0566A - Survey Quality Plan - Rev 0

To Fax Number Date: Subject

: : : :

Horizon Survey Company - Survey Manager +971 6 557 3047 Project Responsibilities and SQP Awareness

Project Details
HSC Project Number: Barge / Rig / Barge: Client: PM: CP-SPE-0566A DP 'Gerimal' SPEC Ship Management L.L.C Hamid Ardalany

Table 1 lists the survey personnel and their responsibilities for the execution of the project. The survey personnel must ensure that they are fully conversant with the contents of this SQP. This table (Table 1) must be reviewed and signed by all personnel and be transmitted to the PM prior to commencement of the project activities which confirms their acknowledgement and understanding of the survey tasks at hand. Personnel Responsibilities and SQP Awareness Ser No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Activity Survey Procedures QC & Approval Survey Procedures QC Survey Procedures Creation Survey Procedures QC & Overall Project Leader Offshore Project Leader Client Liaison PDR Creation Online Configuration Setup Geodesy Verification Online Configuration QC Check Sending Project Check List to Office Gyro Calibration Position Verification Transit Checks Velocity Casts (CTDS) Offset Measurements Person Responsible Survey Manager QC Surveyor Base Surveyor Project Manager Party Chief Party Chief Party Chief Senior Surveyor Senior Surveyor Party Chief Party Chief Senior Surveyor Senior Surveyor Senior Surveyor Senior Surveyor Senior Surveyor
Page: vii CP-SPE-0566A - Survey Quality Plan - Rev 0

Name(s) Ashraf Deyab Ursula Bell Karina Bensemann Hamid Ardalany

Signature for Awareness and Accountability

Personnel Responsibilities and SQP Awareness Ser No 17 18 19 20 21 22 23 24 25 26 Activity Calibration Reports Logbook Keeping Sensor Interfacing Navigation strings to sensors Data Logging Overall Project QC Project Data Backup Returning Project Data to Office Returning Project Field File to Office Report Writing Person Responsible Party Chief Senior Surveyor Senior Surveyor Senior Surveyor Senior Surveyor Party Chief Party Chief Party Chief Party Chief Party Chief / Senior Surveyor Name(s) Signature for Awareness and Accountability

Table 1: Personnel Responsibilities and SQP Awareness

If there is any conflict between the said procedure and the requirement for the field operations or an instruction from the client, the PC must contact the PM and inform him of the situation and discuss an alternative solution/methodology which will not influence the quality of the survey results. Any variation/alteration to the said procedure in the field must be compiled in a variation by the PC and approved (signed off) by the client / representative. A copy of the variation will be transmitted to the PM. In addition to the offshore staff, the necessary administration, logistics, mobilisation, demobilisation and technical support staff will support the project to ensure efficient performance of data acquisition operations It is the responsibility of all personnel to conduct the survey operations in accordance with the said procedures and within the contract specifications. All equipment is to be used within their specification limits and in accordance with the manufacturers specifications and the standard operating procedures. All survey personnel are responsible for the optimum use of the survey equipment mobilised as well as the responsibility for the quality of the data gathered and are to ensure that the data is of maximum achievable quality. All data must be appropriately documented and labelled for inclusion in the associated reports and charts. The following personnel will be involved in this phase of the project: One (1) Party Chief. Two (2) Surveyors. Two (2) Engineers. One (1) MBES / CAD Processors.

Page: viii

CP-SPE-0566A - Survey Quality Plan - Rev 0

1.

INTRODUCTION
SPEC Ship Management L.L.C (Client) has contracted Horizon Survey Company (FZC) to provide surface and subsurface positioning services during the installation of supports for the proposed Foroozan 24" FZ-A to Kharg export pipeline project, Persian Gulf, offshore Iran.

1.1.

Reference Documentation 1. 2. 3. SPEC Ship Management LLC and HSC agreement reference no. SPE/HOR/10/001 dated November 2010. th Client supplied table entitled crossing list received 20 December 2010 Client Supplied Drawing no.: FE560-0000-PL-DW-1657, Sheets 1-12, Revision D0

1.2.

Scope of Work A total of eleven (11) steel structure supports (mattresses) are to be installed for the proposed Foroozan 24" FZ-A to Kharg export pipeline. The objectives of this project can be summarised as: To assist with the installation of the mattresses using USBL underwater positioning and underwater gyrocompass. To cross check the position of the mattresses against the existing pipeline, by deploying a Sector Scan Sonar. To measure the final as-installed position of the mattresses using USBL underwater positioning and underwater gyrocompass. To measure the final as-installed position of the mattresses by using MBES. To provide a report on the final as-installed positions of the mattresses (including a 3D image of the mattresses using the MBES data).

Refer to Diagram 1 for the project location diagram and the proposed pipeline locations. This SQP (CP-SPE-0566A - Survey Quality Plan - Rev 0) outlines the project SoW, detailed methodologies / procedures and resources required to efficiently complete the SoW and fulfil the client requirements. The above mentioned objectives will be achieved by utilising the instruments/equipment listed in Table 2 onboard the DP 'Gerimal' for their associated application: Survey Sensors/Equipment No 1 2 3 4 5 6 7 8 9 10 11 Sensor / Equipment C-NAV DGPS Positioning System (PPS mode) TSS Gyro Compass Navigation and Data Logging Computer Reporting Computers Remote Monitors USBL system Underwater Gyro Compass CTDS Probe Sector Scan Sonar MBES & Motion Sensor IP Thuraya System (TBC) Application Provide precise surface positioning to the DP 'Gerimal'. Provide precise heading to the DP 'Gerimal'. Provide logging and on screen navigation (heading). Provide Report station. Additional stations for processing. To provide underwater positioning during mattress support installations. To provide underwater heading, pitch & roll during mattress support installations. To provide sound velocity through the water profile. Seafloor imagery system. To provide as-installed positions of structure supports. Internet/phone access.

Table 2: Survey Sensors/Equipment Page: 1 CP-SPE-0566A - Survey Quality Plan - Rev 0

A full equipment list and specifications are attached as Appendix A. All offshore elevations and bathymetry will be reduced to L.A.T. The positioning accuracy is required to 1 m on a horizontal plane, and 1 degree in heading during crossing support installation. The following measures will be taken to reduce error and achieve this accuracy; a. b. c. d. 1.3. 1.3.1. Utilise PPS mode for the C-Nav DGPS systems. Final position logging of at least 15 minutes using USBL. Sector scan image to confirm the distance of the installed support with the existing pipeline/cable MBES survey results to be compared with USBL logging.

Client Supplied Information Crossing positions of the proposed Foroozan 24" FZ-A to Kharg export pipeline The crossing positions along the proposed Foroozan 24" FZ-A to Kharg export pipeline, as per Table 3 were supplied by the client (Reference 2 and Reference 3). Foroozan 24" FZ-A to Kharg - Pipeline Crossing Locations Crossing No. FE-C01 FE-C02 FE-C03 FE-C04 FE-C05 FE-C06 FE-C07 FE-C08 FE-C09 FE-C10 FE-C11 Sequence 1 2 3 4 5 6 7 11 8 9 10 Pipeline / Cable Name Unknown KHARG to LAVAN,SIRI cable Terminal AC2882/Oil pipeline ARDESHIR to DARIUS Falcon-S07a-RPL-PL06-Abridged FOG cable Falcon-S06b-RPL-PL01-Abridged Sub sea Cable for LAVAN,SIRI,KHARG and BAHREGAN District Sub sea Cable for LAVAN,SIRI,KHARG and BAHREGAN District 16" product flow line F-17 to FZ 16" product flow line F-17 to FZ 20 M.O.L to Kharg Island Crossing Location Easting (m) 424 918.86 424 372.42 418 814.96 391 626.85 389 042.86 388 529.03 376 615.94 375 081.31 374 856.34 374 563.05 374 530.48 Northing (m) 3 232 565.29 3 231 718.20 3 223 103.16 3 180 956.18 3 176 950.49 3 176 153.95 3 157 686.34 3 154 339.46 3 153 897.80 3 153 167.03 3 152 966.85 KP 7.690 8.705 18.957 69.113 73.880 74.827 96.804 100.513 101.010 101.802 101.960

Spheroid: WGS84, Datum: ITRF 2000 to epoch 1997.0, UTM Zone: 39N, CM: 51 E
Table 3: 24- Foroozan 24" FZ-A to Kharg - Pipeline Crossing Locations

Page: 2

CP-SPE-0566A - Survey Quality Plan - Rev 0

1.4. 1.4.1.

Crossing Support Locations Foroozan 24" FZ-A to Kharg Pipeline Crossing Support Locations The crossing support coordinates for the Foroozan 24" FZ-A to Kharg export pipeline are presented in Table 4, were provided by the client (Reference 2 and Reference 3). Foroozan 24" FZ-A to Kharg Pipeline Crossing Support Locations Support ID FE-S01 FE-S02 FE-S03 FE-S04 FE-S05 FE-S06 FE-S07 FE-S08 FE-S09 FE-S10 FE-S11 FE-S12 FE-S13 FE-S14 FE-S15 FE-S16 FE-S17 FE-S18 FE-S19 FE-S20 FE-S21 FE-S22 FE-S23 FE-S24 Support Type A A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene FE-S22 FE-S23 FE-S24 Centre of Mattress Coordinates Easting Northing (m) (m) 424 921.52 424 372.42 418 814.96 391 626.85 389 042.86 388 529.03 376 609.94 376 613.94 376 617.94 376 622.20 375 075.20 375 081.31 375 087.42 374 850.37 374 854.30 374 858.38 374 862.01 374 557.73 374 561.20 374 564.67 374 568.14 374 523.84 374 527.75 374 532.64 3 232 569.47 3 231 718.20 3 223 103.16 3 180 956.18 3 176 950.49 3 176 153.95 3 157 672.59 3 157 681.76 3 157 690.92 3 157 699.95 3 154 330.30 3 154 339.46 3 154 348.63 3 153 883.41 3 153 892.61 3 153 902.99 3 153 912.24 3 153 154.64 3 153 162.94 3 153 171.25 3 153 179.55 3 152 924.33 3 152 949.70 3 152 980.55 Support angles To Route 33 33 33 33 33 33 24 24 25 25 34 34 34 21 21 21 21 67 67 67 67 64 64 59 To Grid North 82 93 68 73 69 71 66 66 69 69 56 56 56 67 67 67 67 25 25 25 25 73 73 43 KP

Quantity

4+4 1+1 1+1 1+1 1+1 1+1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4+4 4+5 4+6

7.690 8.705 18.957 69.113 73.880 74.827 96.804 96.804 96.804 96.804 100.513 100.513 100.513 101.010 101.010 101.010 101.010 101.802 101.802 101.802 101.802 101.960 101.960 101.960

Spheroid: WGS84, Datum: ITRF 2000 to epoch 1997.0, UTM Zone: 39N, CM: 51 E
Table 4: Foroozan 24" FZ-A-Kharg Pipeline Crossing Support Locations

Page: 3

CP-SPE-0566A - Survey Quality Plan - Rev 0

1.5. 1.5.1.

Survey Line Plan Pre-Installation Survey Prior to installation a single MBES line is to be run to confirm the position of the existing pipelines. This line will be parallel to the pipeline and the length of the line will be a minimum of 50 m. If there is a group of crossings, a single MBES line will be run to combine these locations.

1.5.2.

As-Built Survey A 50 m x 50 m survey is to be conducted, centred on the as-built position of the mattress supports. Table 5 states the line plan requirements. Survey Line Plan Lines Main Lines Cross Lines
Table 5: Survey Line Plan

Line Spacing (m) 50 n/a

Number of Lines 2 1

Orientation Parallel to pipeline Perpendicular to pipeline

The boundary coordinates are to be calculated by the PC, based on the as-installed position of the mattress support. Note: As 100% coverage is required, the line spacing may be reduced in shallow water depths. On the other hand the line spacing in deeper areas can be increased based on the actual acquisition from the MBES and water depths. Both actions can be decided in the field by the Party Chief and client representative. The survey lines shall be terminated / diverted when approaching existing structures.

Page: 4

CP-SPE-0566A - Survey Quality Plan - Rev 0

Diagram 1: Survey Location

Page: 5

CP-SPE-0566A - Survey Quality Plan - Rev 0

2.
2.1.

SURVEY AND REPORTING METHODOLOGIES


Mobilisation A full equipment list is attached as Appendix A. As a minimum the following equipment, as per Table 6 will be mobilised. Equipment Onboard DP 'Gerimal' Ser No. 1 2 3 4 5 6 7 8 9
Table 6: Equipment Onboard DP 'Gerimal'

Equipment C-Nav DGPS with spares on EA or AP Sat (PPS Service) TSS Meridian Gyro Compass Navigation and Data Logging Computer Reporting Computers MBES System & Motion Sensor USBL System (6 Beacons) TSS Meridian Subsea Gyrocompass, with frame and 150 m cable Sector Scan Sonar System CTDS probe

Number (+ Spare) 2 (+ 1) 1 (1 +) 2 (+ 1) 1 (+ 1) 1 (+ 1) 1 (+ 1) 1 (+ 1) 2 (1 +) 1 (+ 1)

During mobilisation all calibrations and verifications (in accordance with Appendix D) will be conducted prior to the commencement of any work. The verifications, calibrations and checks to be completed during mobilisation and in the field prior to the start of survey operations are as follows: All vessel and sensor offset measurements. DGPS verification - primary and secondary positioning systems. Gyro alignment calibration. CTDS wet test USBL calibration. Velocity cast. Transit check. Draft measurement for underwater sensors (MBES & USBL transducers). MBES patch test calibration.

The geodetic computation check shall be cross checked (coordinate transformations) and shall be signed off by the PC and the Client/representative. The geodetic parameters and the QINSY setup parameters are to be transmitted to the office for verification PM and SM. Note: If any of the verifications/calibrations are unable to be conducted during mobilisation or prior to the vessel sailing, the client, PM and SM must be informed. 2.2. 2.2.1. Geodetic References, Datums and Tidal Reduction Geodetic References The primary grid coordinate system to be adopted is the ITRF 2000 to epoch 1997.0 reference system as follows: Spheroid name Datum name Projection name : WGS84 : ITRF 2000 to epoch 1997.0 : Universal Transverse Mercator: (UTM) Zone 39N.
Page: 6 CP-SPE-0566A - Survey Quality Plan - Rev 0

Refer to Appendix C for geodetic details parameters and geodetic computation check. 2.2.2. Vertical Datum All offshore elevations and bathymetry will be referenced to L.A.T. 2.2.3. Tidal Reduction All bathymetric data acquired during the survey will be reduced to the L.A.T. by the simplified harmonic method of tidal prediction. The harmonics and tidal constituents for the survey area were derived from the Admiralty Co-tidal Atlas for the Persian Gulf, NP 214 (refer to Appendix C for details). 2.3. 2.3.1. Vessel Offsets, Horizontal and Height References Horizontal Reference The CRP from which all offsets are to be measured is the primary C-Nav antenna which will where practically possible be located above the vessel bridge on the fore and aft centreline of the vessel. All offsets will be measured using land survey techniques and verified with tape measure during mobilisation. All measurements will be reduced logged and entered into the navigation system and verified by the surveyor / PC. 2.3.2. Vertical Vessel Reference Height references will be related to the main deck level adjacent to the MBES pole. The vertical reference for all sensors is variable based on the vessel draught and freeboard to the main deck. The draught measurement shall be recorded at the following times: Upon the completion of mobilisation before leaving the port. Any time the vessel is alongside. Any time the vessel takes on fuel or water.

The draught measurements are to be logged and provided to the CAD processors onboard. Note: Regular draught readings are to be conducted and recorded in the log book and offsets are to be applied in all relevant software during acquisition. Any discrepancy of observed data must be brought to the attention of the PC onboard and investigated. Any doubt on the validity of the data must be communicated to the PM and SM. 2.4. Field Operations Prior to sailing to site, the surveyor will complete the Personnel Responsibilities and Survey Procedures Awareness form located at the front of this procedures document. This form along with the survey system configuration printout should be faxed back to the Survey Department for checking and approval. Data is to be recorded within QINSy database files throughout the project operations, this is includes (but not limited to) the diving operations. Positioning of the vessel is to be recorded in QINSy on a 24 hour basis while the vessel is in the field. These QINSy database files are to be submitted to the client at the end of the project.

Page: 7

CP-SPE-0566A - Survey Quality Plan - Rev 0

To accurately position the supports during installation, surface and subsurface positioning systems will be used as follows: 2.4.1. Pre-Installation MBES Survey Prior to installation a MBES line is to be run to confirm the position of the existing pipelines against the client supplied information. If the pipeline is within tolerance (2 m) verbal confirmation can be given to the client for approval. If the positions of the pipelines DO NOT match within tolerance (2 m), a field report will be created and approved by the client. Once client approval is obtained, the mattress installation can commence. 2.4.2. Surface Positioning The DP 'Gerimal' will accurately setup over each of the support installation positions, the mattress supports will be lifted and deployed using the DP 'Gerimal' supplied crane wire / frame. Two fixed offsets for both mattress support ends should be accurately measured by the survey crew and added to the positioning and navigation system. Prior to the mattress support deployment, a DGPS position logging will be undertaken to determine the deployment position and heading. The mean position and heading will be calculated upon completion of the logging session. A dedicated subsea gyro, mounted on a temporary support on the mattress and aligned with the mattresss axis, shall provide the mattress heading and inclination (pitch/roll). A CNAV system is to be installed on the crane boom to monitor the position of the crane head at all times. Screen shots for the deployment position and heading of the mattress supports on the navigation display should be recorded. 2.4.3. Underwater Positioning The DP 'Gerimal' will accurately setup over each of the support installation positions; prior to installation a MBES line will be run to confirm the position of the existing pipelines within the tolerance stated above in the Section 2.4.1. To provide a continued relative measurement between the mattress and the existing pipeline two USBL beacons are to be installed onto the existing pipeline. As a simultaneous independent positioning system, two (2) USBL beacons will be installed, two at opposite ends of the mattress support to monitor its position while being lowered to the seabed. An underwater gyro will be installed on the mattress to provide heading and inclination (pitch / roll). Once on the seabed, logging of position fixes for a minimum of 15 minutes will be acquired to determine the as installed position and heading of the mattress support. Mean position, heading and inclination will be calculated upon completion of the logging session of both surface and underwater positioning systems. Upon client acceptance of the final position, heading and inclination (pitch / roll), the USBL beacons and underwater gyro will be recovered by the divers, and the as-built position will be observed using MBES. 2.4.4. Sector Scan Sonar A sector scan sonar is to be deployed during the mattress installation. This will provide a real-time visual observation of the installation. When the mattress support is lowered to the seabed, the distance of the mattress with respect to the existing pipeline is to be measured. A screen shot is to be taken and included as part of the mattress installation report. 2.4.5. As-Built MBES Survey Upon completion of installation of the group of mattresses, a MBES as-built survey is to be conducted to observe the as-built position of the mattress support, in accordance with section 1.5. The PC will advise
Page: 8 CP-SPE-0566A - Survey Quality Plan - Rev 0

the client on the best line plan for achieving the required results and reducing potential infill work. Any deviation from the stated plan must be recorded in a variation and transmitted to the PM and the SM. End of Line QC Procedure: PC on board the vessel need to make sure that on each end of line, the acquired survey data is to be QCd against the project requirements and quality of data.

2.4.5.1. On-Line Navigation and Acquisition Systems The on-line navigation and acquisition systems (QINSy,) will be setup to comply with the following criteria as a minimum: Date, time and position tagging. Sampling and computation of all positioning system data. The cycle time shall not exceed 2 seconds. Processing and real time display of sensor data. QC and verification of data (with hardcopies printouts of non-conforming events/data). Logging of all raw data acquired from the various sensors.

2.4.5.2. Off-Line Processing Systems The off-line processing and charting systems (QINSy, AutoCAD, CARIS etc) shall be used to provide an accurate and complete output from the survey data acquired. In addition to data processing and merging systems, charting systems, standard word-processing and spreadsheet programs, the onboard software programs will be capable to provide the following: 2.4.6. Geodetic transformations. Tidal computations. Reduction of bathymetric data for tides. VoS computations. Editing, approved smoothing and merging routines. Re-computation of surface positioning data from raw data.

Bathymetric Acquisition The bathymetric survey shall be conducted utilising MBES system. A motion sensor will be interfaced to the MBES to compensate for heave, pitch and roll effects. All data shall be digitally recorded for processing. Acquired data digitally logged using QINSy system, will be analysed after processing by the geophysicist, who will produce a detailed report describing the seafloor bathymetric information within the survey limit. The report will be illustrated with bathymetry images of the crossing locations.

2.5.

Real Time QC Monitoring The following sensor information will be displayed in a time series plot on the online navigation computer which will be continuously monitored by the online surveyor: Primary positioning system. Secondary positioning system Sensor updates rates.

The following sensor data will be shown in a time series window for real time comparison: Comparison between primary and secondary positioning systems. Comparison between the surface and underwater positioning systems.

Page: 9

CP-SPE-0566A - Survey Quality Plan - Rev 0

2.6.

Data Processing/Analysis and Reporting All project interfacing, documentation and reporting will be in the English language. The MBES / CAD processor will process the bathymetric and associated data acquired onboard, in accordance with the methodology outlined in Appendix E. The MBES / CAD processor must keep a daily updated processing log for future references and handover. The PC must ensure that all data acquired during the survey is processed in a timely manner and the PC must communicate a daily project status to the PM/SM and client representative.

2.6.1.

Daily Survey Logs Daily survey logs shall be maintained and kept in both soft copies and hard copies in the online operations centre and these shall be made available to the client representative on demand. The daily survey log shall record all the survey activities and factors that may affect the survey operations including: Details of survey lines (start fix & time, end fix & time, heading, vessel speed, etc). Equipment setup, acquisition parameters, failures and changes. Software setup, failures and changes. Changes in the geodetic details (if any). Hard copies roll details. Brief weather information and survey line alteration.

The logs shall be concise, neat and kept in a hard bound volume. 2.7. 2.7.1. Reporting Project Daily Reports The party chief shall compile the project daily reports (PDR) which shall be distributed to all parties concerned with the project. The report shall cover the previous 24 hour period and include the following: DP 'Gerimal' location and date. Operations and work progress for the past 24 hours with details on work time and accumulative statistics. Survey percentages completed should be broken down to individual components. Work planning for the next 24 hours. Standby/downtime periods with causes and details. Formal communications. Equipment failures and changes. Software modifications. Changes in the equipment setup and parameters Personnel movements Current and forecast weather information. Health Safety and Environmental (HSE) issues and incidents including accumulated project safety statistics. Representative comments, Vessel Superintendent and Horizon PC.

The format of the PDR shall be approved by the client prior to mobilisation. The daily content of these reports shall be agreed by the client / representative and the PC and emailed to the client / representative and HSC office prior to 08:00 hours the next day. 2.7.2. Pre-Installation Reports The pre-installation MBES reports are only required when the observed pipelines do not match with the client supplied information (within the specified tolerance of 2 m). The report is to be short (one to two pages), containing a comparison between the client supplied pipeline locations and the MBES observed pipeline locations. This is to include a MBES image illustrating the differences. The report is to be submitted to the client within one working day from completion of the MBES line.

Page: 10

CP-SPE-0566A - Survey Quality Plan - Rev 0

2.7.3.

Crossing Installation Reports There are eleven (11) crossing locations along each pipeline. A report will be issued for each crossing location. These are to be submitted within one day of completion of as-built survey and are required to contain the following; Introduction and summary of operations. Table of final as-built mattress coordinates. Diagram showing the location of the mattress positions in relation to the existing pipeline. A sector scan sonar image showing the mattress in relation to the existing pipeline. MBES image showing the mattress in relation to the existing pipeline.

A crossing installation report will be issued for each crossing location. The volume numbers and report descriptions are as per Table 7. 2.7.3.1. Pipeline Crossing Report Volumes Pipeline Crossing Report Volumes (CP-SPE-0566A) Volume 1 2 3 4 5 6 7 8 9 10 11
Table 7: Pipeline Crossing Report Volumes (CP-SPE-0566A)

Description FE-C01 Crossing report FE-C02 Crossing report FE-C03 Crossing report FE-C04 Crossing report FE-C05 Crossing report FE-C06 Crossing report FE-C07 Crossing report FE-C08 Crossing report FE-C09 Crossing report FE-C10 Crossing report FE-C11 Crossing report

2.7.3.2. Survey Report A survey and operational report template will be issued by the SM to the survey personnel. For this project a survey report will be issued to cover the technical results and operational details of the whole project. Volume 1 of 1, Survey Report, Rev 0 This volume will include a detailed description of the survey activities and results. This report will include but not be limited to the following: Introduction and scope of work. Description of survey objectives. Description of utilised equipment, software, system parameters, barge/vessel, etc. Detailed positioning results. Mobilisation reports, detailing trials and calibrations. Summary of field operations. Personnel and equipments. Health, Safety and Environmental (HSE) issues. Geodetic and navigation parameters. Vessel offset diagram.
Page: 11 CP-SPE-0566A - Survey Quality Plan - Rev 0

2.7.4.

Project daily reports.

Final Survey Report Within seven (7) days from the receipt of client comments on the draft final survey report, HSC should submit the final survey report, which shall include any revisions or amendments requested by client. A Comment Resolution Sheet shall be transmitted along with the final report. In the event that of any corrections are not applied; HSC shall give a justification clearly stating why these were not implemented. On completion of the final report, HSC shall provide digital copies of all final reports, AutoCAD as-built pipeline drawings and other relevant information on CDs/DVDs in native and pdf formats.

2.8.

Report Delivery Schedule Table 8 shows the delivery schedule and number of copies of the as-laid survey reports to be issued to the client on completion of the survey activities. Report Delivery Schedule Report Revision Crossing Installation Report Draft Final Survey Report Final Survey Report Schedule To be issued within twenty four (24) hours from the completion of each as-built survey. Within twenty eight (28) days from date of demobilisation of survey equipment from the vessel/ Within seven (7) days from the receipt of client comments. No. of Copies/Format N/A (To be submitted onboard). One (1) soft copy One (1) soft copy

Table 8: Report Delivery Schedule

2.9. 2.9.1.

Demobilisation Project Demobilisation Upon completion of all survey activities to the clients satisfaction, the survey vessel will proceed for demobilisation. The demobilisation will commence upon receipt of the written permission for demobilisation notice from the client to confirm that all required survey has been completed.

2.9.2.

Project Backup Project data will be backed up on a daily basis to a suitable media (i.e. RDX Tapes/CDs/DVDs), thought the entire duration of the survey project. Two (2) separate copies of the project will be made and brought back to the Horizon Survey office. Note: On completion of survey operations the project directories will be cleaned of any temporary files. The project folder/files must be completed and up to date at the time of demobilisation prior to final backup and returning to the office. The project debriefing form is to be completed prior to the demobilisation and handed/transmitted to the PM at the first available opportunity.

Page: 12

CP-SPE-0566A - Survey Quality Plan - Rev 0

3.
3.1. 3.1.1.

QUALITY CONTROL
Quality Policy and Objectives Quality Policy The Management of Horizon recognises the need to ensure that its services conform to customers' specified requirements in all aspects including professional, legal, safety and environmental criteria. Accordingly, Horizon has developed a Quality Management System to comply with the requirements of ISO 9001:2008/29001:2007. Horizon is committed to provide our customers with the highest quality survey and geotechnical services. We will enhance customer satisfaction by; Employing qualified and experienced managerial and technical personnel who will ensure our work is performed to the highest professional standards and in accordance with the customer specifications. Providing training to the staff. Providing positive and comfortable working environment. Providing safe work place. Providing contemporary equipment. Submitting reports on time. Continually improving the effectiveness of the Quality Management System through periodic Management Reviews and Internal Audits.

3.1.2.

Quality Objectives Horizon Surveys Quality Management System has been implemented to achieve and sustain the following objectives: Increase knowledge base for personnel. Improve equipment tracking efficiency for projects. Reduce equipment downtime on projects. Submit proposals on time. Submit reports on time. Improve project performance awareness. Reduce insurance claims.

3.2.

Horizon Survey Organisation HSC is one of Horizon Group of Companies which provides survey services to the offshore industry in the Middle East and India. The management and company staff have resided and worked in the region for several years, and their experience, track record and regional knowledge is well established. HSC is being managed through an organization which proves of being efficient and successful (Refer to Appendix F for details).

3.3.

Standard QC Check List It is HSCs standard QC practice that at least two senior staff members should ensure all activities are checked against standards and project requirements and that each particular activity is approved. Generally, any activity which has not been approved will have to pass in a loop of re-execution and QC till it gets approved. The quality control check list referenced in Appendix G is being employed as a QC reference during the execution of all HSC projects

Page: 13

CP-SPE-0566A - Survey Quality Plan - Rev 0

4.

PROJECT DELIVERABLE CHECK LIST


Table 9 states the list of deliverables to be transferred from the vessel to HSCs office throughout the duration of the project and at the time of demobilisation. CP-SPE-0566A - Deliverable Check List Item Project Setup Personnel responsibilities and SQP awareness QINSy configuration Vessel offset diagram Geodesy computation check Calibrations & QC DGPS health verification report Gyro calibration report Transit check report MBES patch test calibration report Survey line logs USBL calibration Reports Pre-installation reports (only where exceed tolerance) & related diagram Mattress installation summary reports Crossing installation reports & related diagram Survey reports (one per site/route) Project daily reports Project Data Complete project directory Project check list 24 hr data logging
Table 9: CP-SPE-0566A - Deliverable Check List

Formats / Media Required Hard copy PDF AutoCAD 2000 & PDF PDF MS-Excel & PDF MS-Excel & PDF MS-Excel & PDF MS-Word & PDF Hard copy/MS-Excel/PDF PDF

Completed

MS-Word & AutoCAD MS-Excel MS-Word & AutoCAD MS-Word Signed hard copies/MS-Excel/PDF

RDX tapes (2 Copies) Hard copy DVD / HDD

Page: 14

CP-SPE-0566A - Survey Quality Plan - Rev 0

5.

HEALTH, SAFETY AND ENVIRONMENT


All work shall be performed in a safe and efficient manner. All personnel shall be familiar with the Horizon Survey Health and Safety system. At the most basic level, offshore staff shall take sensible responsibility for their personal health and safety, and that of their co-workers. When venturing out on deck appropriate safety gear shall be worn at all times, this will include, but not limited to: Coveralls. Safety helmet. Safety boots. Safety glasses. Ear defenders. Gloves. Work vests/life jackets. Safety harness.

Life jackets and continuous monitoring are mandatory when working near the side of the vessel or on the aft deck. HSC personnel shall abide by the company environment, health and safety policies and procedures whilst onboard and shall attend all relevant safety meetings, toolbox talks and drills. 5.1. HSE Policy HSC recognises that the safety of people and the protection of the environment is a critical element of our business, and we are committed to conducting our operations in a safe and environmentally responsible manner. This will be achieved by adherence to a structured HSE Management System which addresses the responsibilities of the companys management, staff, subcontractors and other parties involved in the performance of our operations. With regard to the Horizon Survey HSE Management System, we commit ourselves to the following: Provide our employees and sub-contractors with a safe environment in which to perform their work. Provide a formal set of HSE related rules, procedure and guidelines within which our operations are to be performed, and demand strict compliance from our staff and sub-contractors. Provide training and advice to our employees in matters of HSE compliance. Encourage feedback and suggestions, and seek effective ways to implement them. Enforce a clear system of HSE accountability within our organisation. To continuously learn from all feedback and experiences by considering ways to prevent a future re-occurrence, and improving the way we deal with the relevant HSE issue. To execute all our work in such a way as to minimise the impact to the environment and preventing pollution. Comply with Statuary Government and Industry Legislation, Industry Best Practice and Client policies relating to Health and Safety and Environmental Protection.

Managing Director of Horizon Survey has the overall responsibility for ensuring this policy is implemented and fully supported. The system will be reviewed on an annual basis to assess its effectiveness. It is the responsibility of all HSC staff and contractors to ensure that the health and safety of all colleagues is maintained at all times.

Page: 15

CP-SPE-0566A - Survey Quality Plan - Rev 0

5.2.

Environmental and Waste Management Policy Horizon Surveys Management System has been established with the objective to protect the environment and reduce and manage waste in accordance with local and international environmental practices. HSC actively maintains these standards to ensure that the survey services provided to the client are conducted in an environmentally safe and efficient manner. We commit to managing our environmental effects and wastes in compliance with our legal obligations. Furthermore, we will strive to continually improve all our operations and specifically commit to: Work to achieve the environmental expectations of our staff, customers, suppliers and local community. Apply best practice standards for environmental management. Improve efficiency of operations to minimise water and raw material use, energy consumption, waste and pollution generation. Create awareness among our staff and suppliers of the potential environmental effect of operations with which they are involved, and how they can work towards minimising these environmental effects. Continue to conduct regular assessments of the environmental effects of our operations to identify potential areas for improvement, and to follow through with programs to achieve these improvements.

5.3.

Drug and Alcohol Abuse Policy HSC takes drug and alcohol abuse as a serious matter and will not tolerate it. HSC absolutely prohibits the use of alcohol or non-prescribed drugs at the work place or while on company premises. It also discourages non-work place drug and alcohol abuse. The use, sale or possession of alcohol or nonprescription drugs while on the job or on company property may result in immediate suspension or discharge. HSC reserves the right to demand a drug or alcohol test of any employee based upon reasonable suspicion. Reasonable suspicion includes, but is not limited to, physical evidence of use, involvement in an accident, or a substantial drop off in work performance. Failure to take a requested test may lead to discipline, including possible termination. HSC also cautions against use of prescribed or over-the-counter medication which can affect your work place performance. You may be suspended or discharged if the company concludes that you cannot perform your job properly or safely because of using over-the-counter or prescribed medication. Please inform your supervisor prior to working under the influence of a prescribed or over-the-counter medication which may affect your performance. HSC will make every effort to assist its employees who wish to seek treatment or rehabilitation for drug or alcohol dependency. HSC will consider continued employment of such an employee as long as the employee adequately addresses continued concerns regarding safety, health, production, communication or other work related matters. You may also be required to agree to random testing.

5.4.

Stop Work Policy HSC believes that all accidents are preventable and empowers all employees, contractors, clients and guests to: Stop any job if they believe that it may cause harm to people the environment or assets. Refrain from actions that are considered a threat to HSE. Contact line managers in a culture of openness and trust to advise of any safety concerns that they have with regards operations they are involved in.

All HSC staff and contractors have a duty to stop any operation if to ensure that the health and safety of all colleagues is maintained at all times. Failure to stop an operation that is believed to be unsafe may make the individual culpable in the event of future investigations.

Page: 16

CP-SPE-0566A - Survey Quality Plan - Rev 0

APPENDIX A EQUIPMENT LISTING & SPECIFICATIONS

Page: 17

CP-SPE-0566A - Survey Quality Plan - Rev 0

Survey Equipment The following survey equipment / software (or similar) will be present during this phase of the project: a. Surface Positioning and Orientation Systems: C-Nav dual frequency DGPS. TSS Meridian Surveyor gyrocompass.

b. Underwater Positioning System: c. Sonardryne 7707, USBL system. TSS Meridean Subsea gyrocompass (Including pitch & roll).

Digital Logging and Processing Systems: QPS hydrographic survey software (QINSy 8.0). Reporting computers. Remote monitors. AutoCAD drafting package. Digitizing, printing and plotting equipment. RDX tapes. Digital camera.

d. Bathymetric Systems: Valeport CTD Monitor CTDS sensor. Simrad EM 3002 MBES system.

e. Seabed Imaging Systems; f. Sector Scan Sonar.

Communication Facilities: SAT phone. Thuraya phone. GSM phones (if within range). Internet connection with independent computer.

g. Land Survey Equipment: Theodolite with tripod and solar filter (during land related calibrations only).

Note: During survey operations, the back-up C-Nav system will be installed/set-up to ensure continuity in the event that the primary system fails.

Page: 18

CP-SPE-0566A - Survey Quality Plan - Rev 0

GPS C-Nav2000 GPS Hardware

The C-Nav [2000 RM] GPS receiver unit provides performance of several decimeters at either 1 or 5 updates per second. The receiver is ideally suited for positioning of dynamic and static vessels or vehicles on a global basis. The C-Nav [2000 RM] receivers feature 10 channels of continuous GPS satellite tracking contained within a compact, rugged, weatherproof housing. For ease of operation and system integration, the C-Nav GPS unit has a single, rugged, waterproof 8-pin connector that provides RS-232 serial ports, a CAN BUS and D.C power. During operation, the C-Nav GPS System can output a subset of NMEA-0183 messages, including QA/QC data, and RAW GPS measurement binary data, for archiving and post-mission kinematic post-processing analysis. The C-Nav [2000 RM] receivers are a single integrated package combining; antennas, geodetic quality dual frequency GPS receiver, communications link, data demodulator, and or control processor, which is rugged, reliable and able to withstand the offshore environment. The system is capable of receiving differential corrections from AP satellite as well as EA satellite. In the Middle East, the primary system will use AP satellite and the secondary system will use EA satellite.
Specifications

Note: This specification is subject to change without notice.

www.horizonsurvey.ae

Gyro TSS MERIDIAN SURVEYOR


The new Meridian has been designed to be the smallest, lightest, most flexible and accurate mechanical gyrocompass available to commercial users. The new Meridian Surveyor boasts a wide range of interfaces to enable use on any marine vessel. The unit utilises a DTG gyro element which provides exceptional performance with accuracy unmatched by even the latest fibre optic designs. Unlike conventional spinning mass gyrocompasses, the Meridian Surveyor uses a dry tuned element (DTG) that removes the need for routine maintenance thereby significantly reducing cost of ownership. Hence the Meridian Surveyor provides reliable, maintenance free operation with an MTBF in excess of 30,000 hrs.
Specifications Display type Settle point Static accuracy Dynamic accuracy Follow up speed Settling time Latitude input Speed input Latitude compensation Speed compensation Operating temperature Storage temperature Gimbal limits Shock Mean time before failure Service interval Input voltage Start-up current Dimensions Weight Accessories included Options Standards 360 compass card and VFD display 0.1 secant latitude 0.05 RMS secant latitude 0.2 secant latitude 200/sec <40 minutes, to within 0.7 Automatic via RS232 or RS422, NMEA 0183 from GPS or Manual Automatic via RS232 or RS422, NMEA 0183 from log or pulse/contact closure at 100, 200 or 400 per NM from log or manual 80N to 80S 0 90 knots -15C to +55C -25C to +80C 45 pitch and roll 10g 45,000 hours No schedule maintenance, calibration recommended every 2 years 24VDC (18-36 VDC) 1.8A at switch on 344mm (h) x 267mm (w) x 440mm (d) 15.5 Kg Operators handbook, transit case, spare connectors Repeaters and ancillaries IMO A 424 (X1), IMO A 821 (1bv9), BS EN 60945, BS EN ISO 8728 1994, BS 6217 1981, CE Marking, Electromagnetic Compatibility (EMC) Directive and the Marine Equipment Directive 96/98/EC 18 months international warranty including parts and labour Step by Step (5V TTL) 6 steps/1 1 x 26V, 400Hz, 360 (1:1 ratio) 11.8V line to line 5 x RS422; 5 x RS232; 5 x 20mA loop ROT 20/sec (10mA); 1x 5V TTL system ready ; 1 x 5V TTL power fail/gyro fail

Warranty S type output format Synchro output format Serial data output format Analogue output

Note: This specification is subject to change without notice.

www.horizonsurvey.ae

USBL Sonardyne Scout

www.horizonsurvey.ae

USBL Sonardyne Scout

Note: This specification is subject to change without notice.

www.horizonsurvey.ae

TSS Meridian Subsea Gyrocompass

www.horizonsurvey.ae

TSS Meridian Subsea Gyrocompass


Technical Specifications

www.horizonsurvey.ae

Software Qinsy 8
QINSy A Total Hydrographic Solution!
QINSy 8 provides a user-friendly turnkey solution for all types of marine navigation, positioning and surveying activities. From survey planning to data collection, data cleaning, volume calculations and chart production, QINSy offers a seamless data flow from a large variety of hardware sensors, all the way to a complete chart product. QINSy runs on a standard PC platform under the Windows (NT/2000/XP) operating system. The software is not only independent of sensor manufacturer, but also hardware independent. You are free to buy your own off-the-shelf hardware components and QINSy will work with them. You are not tied to specific hardware in any way.

Extreme Versatility - Survey Applications


From scraping diamonds off the seabed to dumping rock on pipelines, from anchor handling to bathymetric or Side Scan Sonar surveys, its modular design and inherent flexibility makes QINSy perfect for a wide variety of applications. For example, it can be configured to perform: Hydrographic and Oceanographic Surveys Offshore Pipeline Inspection and Pipe-laying Dredging, Marine Construction including Offshore Oil and Gas ROV and AUV Tracking and Data Collection Barge,Tug and Fleet Management Chart and ENC Production Since its launch in 1997, QINSy has been installed on over 500 vessels around the world. In other words, QINSy is setting the standard in marine surveying and chart production.

Great Flexibility - Sensor Support


Since the first release in 1997, a very large number of sensor I/O drivers have been developed, so QINSy can handle almost all your hydrographic related sensors right out of the box. QINSy 8 comes standard with around 600 field-tested I/O drivers. If an existing driver does not meet your need, the I/O Driver Utility will usually let you write your own. Failing that, the modular design of QINSy allows QPS to write additional drivers very inexpensively.

www.horizonsurvey.ae

Software Qinsy 8
QINSy 8 supports the following sensor types: Navigation Sensors - NMEA - GPS, DGPS and RTK - Gyros and Compasses - Range/Range, Range/Bearing and Total Stations - Motion Sensors - ARPA and AIS Bathymetry Sensors - Singlebeam and Multibeam - Mechanical Profilers - SVP and Moving SV Profilers - User Defined Side Scan Sonar Sensors - Digital and Analog - LBL and USBL - Inertial and Doppler - User Defined Auto Pilot Sensors - NMEA - User Defined Magnetometer Sensors - NMEA - User Defined Input and Output of Generic Sensors (analog,weather, rpm, environmental, etc.) - NMEA - User Defined

Very Easy to Use - The QINSy Console


Gathering and organizing the various QINSy 8 programs in a single desktop application, called the Console, makes navigation through the program suite very intuitive at each phase of the project. You are guided through the various program modules designed specifically for survey planning, data collection, data processing and chart production. Moreover, Program Managers provide a complete overview of project status at each phase. The main program modules are: Planning On-line Replay and SSS Processing Processing and Data Cleaning Icons for the following bundled utility programs are easily added to the Console, as are shortcuts to other programs relevant to your daily tasks, e.g.MS Word. Line Database Manager Sounding Grid Utility I/O Tester DXF Converter I/O Driver Editor QINSy Mapping QINSy 3D Visualizer

Comprehensive Survey Planning Never Easier


Survey Lines The Line Database Manager is a comprehensive toolbox for survey planning, allowing the surveyor to manually define, automatically generate and/or import from ASCII and DXF files, the following line types: Targets and Symbols Single Lines Survey Grids Routes Wing Lines Cross Lines Data can also be exported to 1) ASCII 2) DXF The Line Data Manager works interactively in real-time with the Online Navigation Display where points, lines and routes can be generated right in the Navigation Display during data acquisition.

www.horizonsurvey.ae

Software Qinsy 8
Survey Configuration Created at the planning stage with the Setup program, a Template Database contains all survey configuration parameters pertinent to the project. QINSy supports most of the datums, projections, US State Planes, units and geoidal models used world-wide. The template contains vessel shapes, administrative information, as well as vessel offsets and I/O parameters. It is a complete reflection of your current survey set-up, and fully editable to kick-start your next project. Background display Drawing files generated from CAD programs often contain more recent and accurate information than electronic charts. To ensure speedy refresh rates of real-time displays, these files are converted with the DXF Converter to a binary format at the planning phase for subsequent online display as an overlay to ENC data in the Navigation Display.

Real-time Final Results - Data Collection and Output


Raw Sensor Data All raw sensor data is logged and permanently stored in a fast relational database (*.db) to which the entire survey configuration is copied from the template. Raw data can be analysed and edited using the Analyse program, making it ready for the Replay program and generation of new results if that is necessary. Results data (X,Y, Z and attributes) is stored to one of several formats, primarily the QPS internal format (*.qpd), but also to ASCII, FAU or Helical SDS f ormat. Data Storage How raw and results data files are split up during acquisition is your choice. Data may be stored on a line-byline basis, by file size, or by manual intervention. Whatever the method, data is normally stored in several separate databases for convenience in processing. Accurate Timing and Ring Buffers Supremely accurate timing is imperative in many survey situations. QINSy uses a very sophisticated timing routine based on the PPS option (Pulse Per Second) available on almost all GPS receivers. All incoming and outgoing data is accurately time stamped with a UTC time label. Internally, QINSy uses so-called observation ring buffers, so that data values may be interpolated for the exact moment of the event or ping. Real-time DTM Production All computations of position are performed in 3D. In combination with RTK or real-time tide sensors, this means that all depth observations are immediately available in absolute survey datum coordinates. This unique technique is called onthe-fly DTM Production. QPS was the first company introducing the delta heave method, which means that the quality of the final DTM is not longer affected by heave drift caused by vessel turns. Advanced Gridding Methods For multibeam surveys,gridding is the predominant data reduction method. However, achieved reduction usually comes at the cost of loss of resolution. In QINSy 8,QPS introduces 2 new gridding methods, namely; 1. An irregular gridding method in which the size of cells created in real-time is directly related to variation of the seafloor. In general, large cells, more appropriately called tiles, are created in flat seabed conditions and small tiles created in feature rich areas with slopes, wrecks, rocks, and sand ripples. This on-thefly method effectively reduces the volume of data without loss of resolution. 2. A regular multi-level gridding method. Based on the minimum cell size, 5 additional grids are generated on-the-fly. Grid file size is no longer an issue, since there is no limit to the number of grid cells. If the minimum cell size is selected to be 1 x 1 meter, then automatically the following grid levels are being generated: x 2x2 x 4x4 x 8x8 x 16 x 16 x 64 x 64 being the overview level
www.horizonsurvey.ae

Software Qinsy 8
This grid can be used not only for bathymetry, but also for SSS Mosaicing, magnetometerdata, seabed classifications, etc. Both methods provide maximum flexibility in data acquisition since there is no longer any need to pre-define grid boundaries. XYZ Data Reduced point data output to tiles is accompanied in parallel with output of all soundings to a second file (*.qpd, *.sds, *.fau, *.pts or other). Either reduced or full datasets are available for further DTM processing. Side Scan Sonar Snippets Full 3D geo-referenced Side Scan Sonar data, called snippets is available from most modern SSS and multibeam sensors. This geo-referenced SSS data, and/or data from dedicated side scan sonar sensors, is presented in real-time as a mosaic in the multi-layered QINSy Navigation Display. QINSy offers advanced real-time SSS target detection, which means a that SSS processing time is almost cut down to zero. A dedicated SSS data viewer allows you to load, view SSS data and perform target detection in just seconds. Eventing Used in many survey operations like for example pipe-laying, pipeline inspection, and buoy tendering, eventing is a powerful feature in QINSy 8. Using the Event Tablet, events are easily generated with a single mouse click, with an event log stored in real-time. Advanced Dredging Functionality QINSy adds advanced dredging functionality to speed up and control the quality of dredging operations in real-time. The various layers are presented in longitudinal and cross-section views, the latter being dynamically updated based on object heading. The entire dredge process is monitored via the groundbreaking real-time 3D display, employing multiple perspectives from different camera views. If available as 3DS files, objects like dredge heads and hopper dredgers are seen moving in a virtual 3D environment at the same time that the dredged depths are updated in the 3D grid, all in real-time.

www.horizonsurvey.ae

Software Qinsy 8
Speedy Processing - Data Validation, Editing, Calibration and Tide Reduction
Data Cleaning and Filtering Applying various filters and corrections for motion, tide and refraction, QINSy is designed to output almost final results at the time of data acquisition. Moreover, the many quality assurance functions equip the surveyor with tools to qualify results data in real-time. Starting with cleaner and thinned data, effectively reduces time spent in post processing. XYZ Attributes All X, Y, Z and attributes are stored during data acquisition in a fast database, with the following attributes attached to each point: Identification (vessel name, system type, ping number, beam number, etc.) Status (accepted, rejected, filtered, manually edit, etc.) Backscatter Full 3D Geo-Referenced Side Scan Sonar (Snippet) User Defined On-line Flags Quality Parameters The QINSy Processing Manager All XYZ files are listed in the QINSy Processing Manager, tabulated against a history of processes performed on each file. This provides a complete overview of the project processing status. Processing programs are launched from the Processing Manager: The Tide Definition and Processing utility supports various methods for tidal reduction. The Validator supports both manual and automated data cleaning including advanced 3D splined surface cleaning. The QINSy Validator Multibeam exploded the volume of point data and created data handling challenges both at the acquisition and processing phases. The QINSy Validator is probably the most powerful data-cleaning program on the market today. Inherently fast data access allows loading and viewing of millions of points in just seconds. The Validator has 4 different views, 3 of which can be opened simultaneously: Plan View Cross View Profile View 3D View Multibeam Calibration Multibeam calibration with QINSy is inter-active and very easy. The Validator offers tools to calibrate for errors in: Roll Pith Yaw Timing

www.horizonsurvey.ae

Software Qinsy 8
Singlebeam and Multibeam Data Editing Editing of singlebeam or multibeam data has never been easier. A variety of automated cleaning algorithms are available: Apply On-line Flags Clip Below / Clip Above Adaptive Clipping Median and Mean Butterworth 3D Spline Surface Despiker Multiply/Shift The Validator adds fully automated pipeline detection features, such as: Top of Pipe Detection Bottom of Trench Mean Seabed Detection Powerful Side Scan Sonar Functionality Side Scan Sonar data is viewed and processed with the Side Scan Sonar Viewer program. It offers the same look and feel as the SSS Display which is used during data acquisition. Powerful target detection tools allow you to export targets and GeoTIFF images (georeferenced bitmaps) to the QINSy Mapping database to provide a complete targets overview.

Eye-Catching Products DTMs, Profiles, Volumes, Chart Production and ENCs


QINSy Mapping is a powerful processing package for the marine surveying and construction industry.With its many taskspecific macro utilities, the software performs all necessary calculations, quickly and easily produces plots, generates contours and spot soundings, and calculates precise volumes in just seconds. A dedicated add-on module is available to export depth contours and spot soundings directly into IHO S57 ENC vector chart format.

The QINSy 3D Tool generates not only great looking images of the seafloor, but also realistic fly-through video clips ideal for client presentations.

www.horizonsurvey.ae

Software Qinsy 8
QINSy System Definition Single Sensor Support Multiple Sensor Support Dredging Support PPS UTC Timing Support Serial and LANNetwork Driver Support Weighted Least Squares Adjustment DGPS QC Integrated Doppler and Kalman Filters 7 Parameter Datum Shift User Defined Projections and Units Geoidal Models and Sounding Datums Coordinate Conversions Import/Export to ASCII Import/Export to DXF CMap ENC Support IHO S57, Primar, ENC Support AIS Transponder and ARPA Support Real-time I/O and Status Alerts Advanced Quality Control Functions RTK Support On The Fly DTM Production Regular Color Coded Grids Irregular/Tiled Color Coded Grids Multibeam Support and Calibration Pipeline Detection and Eventing SVP Import from File SVP Import from Sensor SVP Real-time Updates Remote Display Client via LAN X-Section View and Profile Display 3D Grid Display 3DS Object Support Tug Management Display Tidal Reduction Complex Tidal Reduction Models 2D/3D XYZ Data Cleaning Automated/Area Cleaning Export to XTF USBL and LBL Support ROV and AUV Support Barge and Fleet Management Side Scan Sonar Imagery Display Side Scan Sonar Processing Full 3D Geo-Referenced Mosaicing Export Contours and Sounding to S57 Maintenance and Support Plan Surface Modeling by TIN Volumes by X-Sections Volumes by Area Cut/Fill Volumes Import/Export to DWG Import/Export to DGN Contours Splined and Overhauser A0 A4 Scaled Plots Site Design Functions Channel Design Functions Single Layer 3D Visualization Arc View Support Draping and Image Overlay Multi Layer 3D Visualization AVI+JPG Lite 9 9 9 9 add-on 9 9 9 9 9 9 9 9 add-on 9 9 9 9 9 9 9 add-on 9 9 9 9 add-on 9 9 9 9 9 9 9 9 9 add-on add-on add-on add-on 9 Survey 9 9 add-on 9 9 9 add-on 9 9 9 9 9 9 9 9 add-on 9 9 9 9 9 9 9 add-on 9 9 9 9 add-on 9 9 9 9 9 9 9 9 9 9 9 9 add-on add-on add-on add-on 9 Office Mapping 3D Tool

add-on 9 add-on 9 9 9 9 9 9 9 9 add-on 9 9 9 9 9 9 9 add-on 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 add-on add-on add-on add-on 9

9 9 add-on 9 9 9 9 9 add-on add-on 9 add-on add-on 9

Note: This specification is subject to change without notice.

www.horizonsurvey.ae

CTDS- Valeport MIDAS

www.horizonsurvey.ae

MBE Kongsberg EM3002


The EM 3002 is a new advanced multibeam echo sounder with extremely high resolution and dynamically focused beams. It is very well suited for detailed seaoor mapping and inspection with water depths from less than 1 meter up to typically 150 meters in the ocean. Maximum depth capability is strongly dependant on water temperature and salinity, up to 300 meters is possible under favorable conditions. Due to its electronic pitch compensation system and roll stabilized beams, the system performance is stable also in foul weather conditions. The spacing between soundings as well as the acoustic footprints can be set nearly constant over the swath in order to provide a uniform and high detection and mapping performance. Dynamic focusing of all receive beams optimizes the system performance and resolution for short range applications such as underwater inspections.
Typical Applications Mapping of harbours, inland waterways and shipping channels with critical keel clearance Inspection of underwater infrastructure Detection and mapping of debris and other underwater objects Detailed surveys related to underwater construction work or dredging Environmental seabed and habitat mapping Mapping of biomass in the water column Features The EM 3002 system uses one of three available frequencies in the 300 kHz band. This is an ideal frequency for shallow water applications, as the high frequency ensures narrow beams with small physical dimensions. At the same time, 300 kHz secures a high maximum range capability and robustness under conditions with high contents of particles in the water. EM 3002 uses a new and very powerful sonar processor in combination with the same sonar head used with the popular and highly acclaimed EM 3000 system. The increase in processing power makes it possible to apply sophisticated and exact signal processing algorithms for beamforming, beam stabilisation, and bottom detection. The bottom detection algorithm is capable of extracting and processing the signals from only a part of each beam, thus making it possible to obtain independent soundings even when beams are overlapping. EM 3002 will in addition to bathymetric soundings, produce an acoustic image of the seabed. The image is obtained by combining the acoustic return signals inside each beam, thus improving signal to noise ratio considerably, as well as eliminating several artifacts related to conventional sidescan sonars. The acoustic image is compensated for the transmission source level, receiver sensitivity and signal attenuation in the water column, so that reliable bottom backscatter levels in dB are obtained. The acoustic seabed image is compensated for acoustic raybending and thus completely geo-referenced, so that preparation of a sonar mosaic for a survey area based upon data from several survey lines is easy. Objects observed on the seabed image are correctly located and their positions can be readily derived. Operator Station The Operator Station is a ruggedized PC workstation running on either Linux or Microsoft Windows XP. The Operator Station software, SIS, has been completely redesigned and expanded compared to the EM 3000 software, adding 3D graphics, real-time data cleaning and electronic map background. The EM 3002 can be set up to use other operational software than SIS, for example QPS QINCy or Coastal Oceanographics HYPACK Max, and is also supported by software from Triton Elics International, EIVA and others.

www.horizonsurvey.ae

MBE Kongsberg EM3002


Operational Specifications Frequencies 293, 300, 307 kHz Number of soundings per ping: Single sonar head Max 254 Dual sonar heads Max 508 Maximum ping rate 40 Hz Maximum angular coverage: Single sonar head 130 degrees Dual sonar heads 200 degrees Pitch stabilisation Yes Roll stabilisation Yes Heave compensation Yes Pulse length 150 us Range sampling rate 14, 14.3 , 14.6 kHz Depth resolution 1 cm Transducer geometry Mills cross Beam pattern Equidistant or equiangular Beamforming: Time delay with shading Dynamically focused receive beams Seabed image data Composed from beamformed signal amplitudes. Range resolution 5 cm. Compensated for source level and receiver sensitivity, as well as attenuation and spherical spreading in the water column. Amplitude resolution: 0.5 dB. External Sensors Position Heading Motion Sensor (Pitch, roll and heave) Sound velocity profile Sound velocity at transducer Clock synchronisation ( 1 PPS) Environmental and EMC Specifications The system meets all requirements of the IACS E10 specification. The Operator Station, LCD monitor and Processing Unit are all IP22 rated. Dimensions and Weights Sonar head: Shape Housing material Diameter Height Weight Pressure rating Sonar Processing Unit Width Depth Height Weight Operator Station Width Depth Height Weight

Cylindrical Titanium 332 mm 119 mm 25 kg in air, 15 kg in water 500 m (1500 m option) 427 mm 392 mm 177 mm 14.5 kg 427 mm 480 mm 127 mm 20 kg

17.4 industrial LCD Monitor Width 460 mm Depth 71 mm Height 400 mm Weight 9.2 kg Resolution 1280 x 1024 pixels All surface units are rack mountable. Dimensions exclude handles and brackets.

Note: This specification is subject to change without notice.

www.horizonsurvey.ae

SSS GeoAcoustic Dual Frequency

The GeoAcoustics Dual Frequency Side Scan Sonar system is the ideal tool for seabed feature mapping, offering flexibility and high quality results in a simple and reliable package. The system offers high resolution, switch selectable, dual frequency operation (114/410 kHz), which when combined with multiplexed data transmission enables a low drag co-axial tow cable to be used. The modular design of the system makes it ideal for combining with our GeoChirp and GeoPulse sub-bottom profilers. The versatility, ease of operation and cost effectiveness of the system has made it a popular choice with commercial survey companies. Standard System The standard system employs a lightweight towfish, which is easily deployed by one person and can operate to a depth of 1000 metres. There are separate controls for each channel, which makes the system very easy to operate. The basic system includes the following: Transceiver (Model SS981) Towfish (Model 159D), which houses the Multiplexer (Model SS982) and Two Dual Frequency Transducers (Model 196D/Port and Starboard). Transceiver The transceiver unit allows the operator a simple means of controlling various Side Scan operating parameters. The unit includes standard controls such as: Gain, Time Varying Gain (TVG) and Automatic Gain Control (AGC), with duplicated controls for Port and Starboard channels. The operating frequency can also be switched from 114 kHz to 410 kHz directly from the Transceiver. The choice of frequencies means that long range scanning and short range high resolution investigations are both possible. Multiplexer The Multiplexer Unit (SS982) is the sub sea processing section of the Side Scan Sonar System. The SS982 is mounted in the tail of the towfish, on the tail of a combined towfish or on an ROV, as required. The use of standard sub-sea connectors throughout allows easy installation in all situations. The SS982 includes all of the transmitter and multiplexing electronics, thereby ensuring that transmission power is not lost in the towcable and also reducing the risk of high voltage defects. The multiplexed data transmission technique employed allows the system to be used with a wide selection of towcables, including twisted pair and co-axial cables. Data from the Dual Frequency Side Scan Sonar can be input to many sonar processing systems, including the GeoPro Sonar Processor, or it can be displayed on a wide variety of industry standard graphic recorders. The multiplexed data offers a resolution equivalent to a 16 bit analogue to digital converter operating at 50k samples/sec per channel, when used with short towcables.

www.horizonsurvey.ae

SSS GeoAcoustic Dual Frequency


Key Features 1000 metre depth rating (standard) Switch selectable dual frequencies Fully multiplexed signals Simple user controls Low cost High efficiency/low power Operates over long towcables Outputs to all standard recorders/processors Simple maintenance Low drag coaxial towcable High system bandwidth and resolution High reliability (MTBF > 10,000 hours)

Options Deeper rated towfish Stainless Steel towfish Lightweight Kevlar Towcable for shallow water use 60kHz operating frequency for increased range Towfish pitch, roll and heading sensors Towfish responder for acoustic tracking Towfish height off bottom measurement Towfish depth sensor Data Acquisition & Processing using a GeoPro Sonar Processor

Technical Specifications Transceiver - Model SS981 General Power requirements: Size: Weight: Temperature: Humidity: Mounting: Operating Specification Power output to tow vehicle: Key burst out: Key input: Receivers Modulation frequency: Bandwidth: Sensitivity: Input impedance: Output impedance: Dynamic range:

95/265VAC switchable, 40-60Hz, 50W, optional 24VDC. 43.2cm W x 45.7cm D x 18.7cm H. 16kg. Storage: -20 to 75C Operating: -5 to 50C. 10% to 95% RH, non-condensing. The unit is suitable for either bench or rack mounting.

150VDC 3VDC, 100mA average, 320mA peak. 455kHz, pulse width selectable 16Vpp, PRR determined by key source. Positive CMOS or TTL, 10kW input impedance.

Output: TVG delay: Event mark: Key out: Modes: Front Panel Connectors BNC: Amphenol:

Port 135kHz, Starboard 65kHz. 15kHz. 6mV rms input produces 800mV rms output with a 20dB signal-to-noise ratio (all gain maximum). 5k . 600 on all outputs. Gain: adjustable over 60dB range. TVG: -20 to +20dB maximum AGC: -34dB maximum. Selectable signal envelope or amplitude modulated 12kHz. 3.3ms minimum, 330ms maximum. 5Vpp, 12kHz, front panel push button or BNC input requiring CMOS or TTL level pulse. Produces visual mark on recording media. 0.6ms CMOS/TTL compatible. 100kHz and 500kHz operation. Raw signal and processed signal.

Seven each for signals and keys. MS3102A-22-34S for deck cable

www.horizonsurvey.ae

SSS GeoAcoustic Dual Frequency


Technical Specifications Multiplexer - Model SS982 Transmitter Section Frequency: Power output: Pulse length: Pulse repetition rate: Protection: Efficiency: Receiver Section Port channel: Starboard channel: Bandwidth: TVG: Keyburst Frequency: Pulse length: General Power requirements: Size: Weight: Towfish Model 159D Tow Speed: Weight: Dimension: Frame: Nose:

114/410kHz 1% 3kW pulse 20% 167sec/88sec 1% 50 pulses per second maximum Open and short circuit protected Greater than 80% 114/410kHz, heterodyned to 135kHz 114/410kHz, heterodyned to 65kHz 20kHz Transmission loss curve compensated at both frequencies Approximately +40dB at 100m range 455kHz 2% 300sec for 114kHz operation 600sec for 410kHz operation 150VDC at 100mA 10.2cm D x 34.5cm L 3.2kg in air, 0.45kg in water

1 to 12 knots 16.3kg, 22.5kg, or 38.6kg depending on ballast used 11.4cm diameter by 128.5cm long, 3 fins on tail protrude 7.5cm Cast aluminium with shear release carry handle/tow point Shock absorbing, abrasive resistant urethane. Cavity can carry small auxiliary transducer

Transducers Model 196D Source Level: Beamwidth: Sensitivity: Depression angle:

223 3dB re 1Pa@ 1m 114kHz - 50 by 1 410kHz - 40 by 0.3 -190dB re 1V/Pa 10 1 down

Note: This specification is subject to change without notice.

www.horizonsurvey.ae

APPENDIX B CLIENT SUPPLIED INFORMATION

Page: 19

CP-SPE-0566A - Survey Quality Plan - Rev 0

Sequence 1 2 3 4 5 6

Crossing FEC01 FEC02 FEC03 FEC04 FEC05 FEC06

ClientSuppliedCrossingDetails24"FZAKHARG Pipeline/cableID Quantity supportNo. SupportType Unknown KHARGtoLAVAN,SIRIcable TerminalAC2882/Oilpipeline ARDESHIRtoDARIUS FalconS07aRPLPL06Abridged FOGcable FalconS06bRPLPL01Abridged
4+4 1+1 1+1 1+1 1+1 1+1 1 1 1 1 1

KP 7.690 8.705 18.957 69.113 73.880 74.827 96.804 96.804 96.804 96.804 100.513 100.513 100.513 101.010 101.010 101.010 101.010 101.802

SupportCoordinates Easting Northin 424918.86 424372.42 418814.96 391626.85 389042.86 388529.03 376609.94 376613.94 376617.94 376622.20 375075.20 375081.31 375087.42 374850.37 374854.30 374858.38 374862.01 374557.73 3232565.29 3231718.20 3223103.16 3180956.18 3176950.49 3176153.95 3157672.59 3157681.76

CrossingCoordinates Easting Northin 424921.52 424372.42 418814.96 391626.85 389042.86 388529.03 3232569.47 3231718.20 3223103.16 3180956.18 3176950.49 3176153.95

SupportAngles toRoute toNorthGrid 33.00 33.00 33.00 33.00 33.00 33.00 24.00 24.00 82.00 93.00 68.00 73.00 69.00 71.00 66.00 66.00 69.00 69.00 56.00 56.00 56.00 67.00 67.00 67.00 67.00 25.00

FES01 FES02 FES03 FES04 FES05 FES06 FES07 FES08 FES09 FES10 FES11 FES12 FES13 FES14 FES15 FES16 FES17 FES18

A A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene A/Neoprene

FEC07

SubseaCablefor LAVAN,SIRI,KHARGand BAHREGANDistrict

376615.94 3157690.92 3157699.95 3154330.30 3154339.46 3154348.63 3153883.41 3153892.61 374856.34


1 1 1

3157686.34 25.00 25.00 34.00

11

FEC08

SubseaCablefor LAVAN,SIRI,KHARGand BAHREGANDistrict

1 1 1 1

375081.31

3154339.46

34.00 34.00 21.00 21.00

FEC09

16"productflowlineF17toFZ 3153902.99 3153912.24 3153154.64

3153897.80 21.00 21.00 67.00

FES19 FES20 FES21 FES22 FES23 FES24

A/Neoprene A/Neoprene A/Neoprene B B A

101.802 101.802 101.802 101.960 101.960 101.960

374561.20 374564.67 374568.14 374523.84 374227.75 374532.64

3153162.94 374563.05 3153167.03 3153171.25 3153179.55 3152924.33 3152949.70 3152980.55

67.00 67.00 67.00

25.00 25.00 25.00

FEC10

16"productflowlineF17toFZ
1 1 4+4

10

FEC11

4+5 4+6

APPENDIX C SURVEY PARAMETERS, TIDES AND UNITS

Page: 20

CP-SPE-0566A - Survey Quality Plan - Rev 0

GPS Geodetic Parameters The geodetic parameters for the WGS84 Spheroid and Datum are as per Table 10. GPS Geodetic Parameters Parameter Spheroid Semi-Major Axis (a) Semi-Minor Axis (b) First Eccentricity Squared (e ) Inverse Flattening (1/f) Datum Source: USDoD
Table 10: GPS Geodetic Parameters
2

Value World Geodetic System 1984 (WGS84) 6 378 137.0 m 6 356 752.314 m 06 694 379 990 298.257 223 563 ITRF 2000 epoch 1997.0

Project Geodetic Parameters The Spheroid Projection and Transformation parameters as per Table 11 are to be utilised throughout the duration of the project and within this procedure document. Project Geodetic Parameters Parameter Spheroid Semi-Major Axis (a) Semi-Minor Axis (b) First Eccentricity Squared (e ) Inverse Flattening (1/f) Datum Projection Central Meridian (CM) Latitude of Origin False Easting False Northing Scale Factor on CM Translation Rotation Scale Factor Rotation Convention Source HSC
2

Value WGS84 6 378 137.0 m 6 356 752.314 m 06 694 379 990 298.257 223 563 ITRF 2000 to epoch 1997.0 Universal Transverse Mercator 51 E (UTM Zone 39N) 0 500 000 m 0m 0.999 60 00 dx 00 rx 00 ppm Coordinate Frame Rotation (Right Handed Convention) 00 dy 00 ry 00 dz 00 rz

Transformation Parameters (ITRF 2000 epoch 1997.0 to ITRF 2000 to epoch 1997.0)

Table 11: Project Geodetic Parameters

Page: 21

CP-SPE-0566A - Survey Quality Plan - Rev 0

Geodetic Computation Check On completion of mobilisation a geodetic computation check will be conducted using the online navigation software to transform a coordinate from ITRF 2000 epoch 1997.0 datum to the ITRF 2000 to epoch 1997.0 local datum which will be utilised during the project. A computation check test coordinate with results is stated as per Table 12. Geodetic Computation Check Spheroid / Datum WGS84 Spheroid ITRF 2000 epoch 1997.0 Source: HSC
Table 12: Geodetic Computation Check

Geographical Coordinates Latitude 26 36 39.098 Longitude 051 47 30.875

Grid Coordinates Easting 578 839.62 Northing 2 943 579.70

Vertical Control All bathymetric data acquired during the survey will be reduced to L.A.T. by using the simplified harmonic method of tidal prediction. Tidal harmonics for the field were derived from the Admiralty Co-tidal Atlas for the Persian Gulf, NP 214. The tables below list the tidal harmonics for the sites to be surveyed.

Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1

Tidal Harmonic Constituents FZ-A 2829'49.73"N, 4942'59.687"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 268.17 238.93 309.47 261.16 H (metre) 0.06 0.02 0.32 0.21 0.74

Zo = 1.2x(M2H+S2H+K1H+O1H)

Page: 22

CP-SPE-0566A - Survey Quality Plan - Rev 0

Tidal Harmonic Constituents Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1 Zo = 1.2x(M2H+S2H+K1H+O1H) 2834'32.98"N, 4945'51.519"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 267.12 265.46 307.69 260.04 H (metre) 0.09 0.03 0.33 0.21 0.79

Tidal Harmonic Constituents Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1 Zo = 1.2x(M2H+S2H+K1H+O1H) 2839'7.765"N, 4949'7.97"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 265.64 285.89 305.94 258.45 H (metre) 0.13 0.04 0.33 0.22 0.86

Tidal Harmonic Constituents Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1 Zo = 1.2x(M2H+S2H+K1H+O1H)
Page: 23

2843'42.477"N, 4952'24.701"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 265.18 296.33 304.34 256.93 H (metre) 0.16 0.05 0.34 0.22 0.92
CP-SPE-0566A - Survey Quality Plan - Rev 0

Tidal Harmonic Constituents Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1 Zo = 1.2x(M2H+S2H+K1H+O1H) 2848'17.114"N, 4955'41.714"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 265.68 304.35 302.76 255.54 H (metre) 0.20 0.07 0.34 0.22 0.99

Tidal Harmonic Constituents Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1 Zo = 1.2x(M2H+S2H+K1H+O1H) 2852'51.675"N, 4958'59.01"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 265.79 311.90 301.33 254.42 H (metre) 0.23 0.08 0.35 0.22 1.05

Tidal Harmonic Constituents Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1 Zo = 1.2x(M2H+S2H+K1H+O1H)
Page: 24

2857'26.16"N, 502'16.59"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 266.23 317.94 299.99 253.36 H (metre) 0.26 0.09 0.35 0.23 1.11
CP-SPE-0566A - Survey Quality Plan - Rev 0

Tidal Harmonic Constituents Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1 Zo = 1.2x(M2H+S2H+K1H+O1H) 292'0.568"N, 505'34.457"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 266.46 322.65 298.85 252.42 H (metre) 0.28 0.10 0.36 0.23 1.17

Tidal Harmonic Constituents Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1 Zo = 1.2x(M2H+S2H+K1H+O1H) 296'34.899"N, 508'52.611"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 266.96 327.36 297.70 251.55 H (metre) 0.31 0.12 0.37 0.23 1.23

Tidal Harmonic Constituents Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1 Zo = 1.2x(M2H+S2H+K1H+O1H)
Page: 25

2911'9.15"N, 5012'11.054"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 267.32 330.44 296.60 250.77 H (metre) 0.34 0.13 0.37 0.24 1.29
CP-SPE-0566A - Survey Quality Plan - Rev 0

Tidal Harmonic Constituents Location Position (WGS84) Constituent Time Zone Prediction Method Datum Constituent M2 S2 K1 O1 Zo = 1.2x(M2H+S2H+K1H+O1H) 2914'53.61"N, 5016'38.824"E GMT+04.00 Simple Harmonic Method LAT G (Degrees) 265.69 330.86 295.37 249.79 H (metre) 0.36 0.14 0.38 0.24 1.34

Survey Units The survey units of measure used during the project are represented in Table 13. Project Survey Units Type Time Linear units Velocity Angular units
Table 13: Project Survey Units

Unit Local Time (GMT + 03:30 hours). Navigation data will be logged in GMT + 00:00 hours. International Metres (m). Metres per second (m/s). Degrees, Minutes, Seconds ( ).

Page: 26

CP-SPE-0566A - Survey Quality Plan - Rev 0

APPENDIX D SYSTEM VERIFICATIONS & CALIBRATIONS

Page: 27

CP-SPE-0566A - Survey Quality Plan - Rev 0

SYSTEM VERIFICATIONS Prior to the survey acquisition, a number of system verifications and checks should be carried out during the mobilisation stage in port and later in field to ensure that all systems are operational and working according to the planned operating parameters and tolerances. In-Port Verifications The following verification and checks must be carried out during the mobilisation stage and prior to the vessel sailing to site. Note: If one or more of the following verification/checks are unable to be conducted prior to the vessel sailing the Survey and Project Managers must be contacted and informed to replace it with alternate verification/check. All positional related calibrations (DGPS, Transit Fix, etc), should be carried using PPS mode. The verifications, calibrations and checks to be conducted in-port are: Vessel offset measurements. DGPS verification for primary and secondary positioning systems. Gyro alignment calibration. Static USBL Calibration Draft measurement for underwater sensors (USBL and MBES transducer, etc). Water height measurement for height reference. Wet and acquisition testing for all survey sensors.

- Vessel Offset Measurements The C-Nav antenna should be the designated as the Common Reference Point (CRP) for the horizontal control on the vessel. All offsets of different navigation and survey sensors are to be measured to the primary C-Nav antenna, which has to be located (if applicable) above the bridge on the centreline of the vessel. All offsets to be measured using land survey techniques during vessl mobilisations and to be independently rechecked manually using measure tapes. The acquired measurements should be reduced, logged, entered to the navigation system and provided to the project survey data processors onboard. - Static DGPS Health Verification A DGPS health verification should be carried out in port prior to the vessel sailing. The DGPS health verification should be carried out for both primary and secondary DGPS systems independently. There are three different methods to carry out the verification. Method 1: Set up the GPS antenna over a well known land control station in the port and the received DGPS positioning data to be logged for a period of at least 60 minutes. The mean position value derived should be compared against the known position of the land control station. If it is not possible to locate the GPS antenna over a land control station, X & Y offsets should be measured from the land control station to the antenna. The comparison should take the physical offset between the land control station and the antenna into consideration. Method 2: Utilise land survey techniques, by setting up the total station over a nearby land control station, to carry out set of observations to the GPS antenna accompanied with simultaneous logging for the DGPS position data. The results of both survey sessions should be reduced based on the time of each land observation, the mean values to be calculated and compared against each other.

Page: 28

CP-SPE-0566A - Survey Quality Plan - Rev 0

Note: During this method, the surveyor should make sure to synchronise his watch to the navigation system time and to record the time at each land observation to be used later during data reduction.

Quay Side

Quay Side

Diagram 2: DGPS Verification Diagram, First Method

Diagram 3: DGPS Verification Diagram, Second Method

Method 3: Compare the position of both primary and secondary DGPS systems against each other. In this method, a simultaneous logging session for the DGPS positioning data for both primary and secondary GPS antennas should be recorded for a period of at least 60 minutes. The derived position values should be reduced and compared against each other considering the physical distance between the two antennas.
Quay Side

Diagram 4: DGPS Verification Diagram, Third Method

Note: During this method, the surveyor should make sure to enable the differential GPS (DGPS) correction. Raw GPS position information should not be used during the DGPS verifications. During this method, the surveyor should make sure to eliminate all the possible causes of the known sources of GPS errors to ensure the best quality of the data acquired.

Page: 29

CP-SPE-0566A - Survey Quality Plan - Rev 0

- Gyrocompass Alignment Calibration On completion of the DGPS verifications, a gyrocompass alignment calibration shall be conducted by the surveyors to determine the constant misalignment (difference) between the vessel gyro heading and the survey gyrocompass heading. The gyrocompass misalignment is variable and depending on the way and where the gyrocompass is installed. This misalignment is different from the fixed gyro error which it has to be derived in workshop by calibrating the gyro against a well known baseline. The fixed gyro error (if exists), should be written on the gyro. Note: Prior to the commencement of calibration operations, the surveyor should ensure the gyrocompass has had sufficient time to settle, and that the unit is firmly secured to the deck. The gyro correction should be set to zero within the navigation software prior to the gyro alignment calibration, unless, the value of the fixed gyro error is not equal zero. In this case, this error should be corrected by applying the same value with opposite sign to the navigation software prior to running the misalignment calibration. There are three different methods to carry out the gyrocompass misalignment calibration. Method 1: Utilise the land survey techniques, by setting up the total station over a nearby land control station, to carry out set of observations to the bow and mid-stern of the vessel to calculate the grid heading of the vessel accompanied with simultaneous data logging (1 second update) for the gyrocompass heading data. The results of both survey sessions should be reduced based on the average time of each land observation set, the mean values to be calculated and compared against each other. Once one set has been completed the vessel will be turned through 180 and the calibration will be repeated. Note: During this method, the surveyor should make sure to synchronise his watch to the navigation system time and to record the time at each land observation to be used later during data reduction. Also, for each set, one shot to the bow and another to the mid-stern, the observations should be quick to avoid the significant vessel movements between observations. The convergence between true and grid headings should be taken into consideration during the calculation of this method.

Page: 30

CP-SPE-0566A - Survey Quality Plan - Rev 0

Quay Side

Quay Side

Diagram 5: Gyro Calibration Diagram, First Method

Diagram 6: Gyro Calibration Diagram, Second Method

Method 2: Utilising the quay side with a well known heading to be used as a baseline to calculate the gyrocompass misalignment. Offset measurements from the quay side to two different points on the side of the vessel, one point towards the stern and the other towards the bow, will be simultaneously acquired utilising measure tapes (measurements will be undertaken over a period of 30 minutes). These tape measurements will be accompanied with simultaneous data logging (1 second updates) for the gyrocompass heading data. The measurements should be corrected to be calculated to the vessel centreline and the vessel heading to be calculated. The results of both survey sessions should be reduced based on the average time of each tape measurement set, the mean values to be calculated and compared against each other. Upon completion of the calibration the vessel will be turned through 180 and once the gyro has had time to settle, the calibration will be conducted once more. Note: During this method, the surveyor should make sure to synchronise his watch to the navigation system time and to record the time at each tape measurement set to be used later during data reduction. The convergence between true and grid headings should be taken into consideration during the calculation of this method. Method 3: Utilise two independent DGPS systems to calculate the vessel heading. In this method, the GPS antennas have to be installed at the vessel bow and the mid-stern to form a baseline collinear with the vessel centreline. This baseline should be as long as possible to ensure the best quality of the data acquired. These DGPS data acquisition will be accompanied with simultaneous data logging for the gyrocompass heading data. The received DGPS positioning data should be logged for a period of a minimum of 60 minutes at an update rate of 1 second. The results of the DGPS baseline logging session will be reduced and used to calculate the vessel grid heading. The heading value will be compared against the mean value of the gyro heading data. Once the logging period has been completed the vessel will be turned through 180 and the gyro will be allowed to settle prior to the calibration being repeated.

Quay Side

Diagram 7: Gyro Calibration Diagram, Third Method

Page: 31

CP-SPE-0566A - Survey Quality Plan - Rev 0

Note: During this method, the surveyor should make sure to eliminate all the possible causes of the known sources of GPS errors to ensure the best quality of the data acquired. The convergence between true and grid headings should be taken into consideration during the calculation of this method. Upon the completion of gyrocompass calibration, the algebraic sum of both the fixed error and the misalignment calibration should be entered to the navigation software. - Static USBL Calibration On completion of the gyrocompass calibration and installation of the underwater positioning system (USBL), a static USBL system calibration should be carried out to detect and rectify gross error in the installation of the USBL system transducer. The static USBL calibration to be carried out by logging the underwater positions for two transponders deployed simultaneously to a depth of one (1 m) above the seabed level. The transponders have to be deployed at the vessel bow and the mid-stern to form a baseline collinear with the vessel centreline. The USBL underwater positioning data for both transponders should be recorded for a period of at least 15 minutes. The USBL data acquisition will be accompanied with simultaneous data logging for the gyrocompass heading data. The results of the USBL logging session should be reduced and used to calculate the grid heading of the baseline between the two transponders. The calculated baseline heading value to be compared against the mean value of the gyrocompass heading data, the difference will represent the heading misalignment for the USBL system transducer. Note: Prior to the commencement of calibration operations, the surveyor should ensure the gyrocompass calibration result has been entered to the navigation software. The USBL corrections should be set to zero within the USBL surface unit and the navigation software prior to the USBL calibrations. In Field Calibrations The following calibrations / activities are to be conducted in field and prior to and during survey operations. Transit check. Sound velocity measurements. USBL calibration. MBES calibration. Sector Scan Sonar verification.

- Transit Fix Check To confirm that the correct geodetic parameters have been entered into the survey software a Transit Fix Check shall be conducted around an existing platform in both a clockwise and anti-clockwise direction. - Sound Velocity Measurements A velocity cast shall be conducted upon arrival on location to measure the velocity of sound waves in water. The average value from the velocity cast shall be inputted into the USBL / MBES system. Velocity casts shall be conducted once a day during survey operations.

Page: 32

CP-SPE-0566A - Survey Quality Plan - Rev 0

- Dynamic USBL Calibration Introduction The USBL (Ultra Short Base Line) system is an underwater navigation system that measures range and bearing to a transponder which is attached to the towed SSS or SBP system. Range and bearing are derived from phase difference measurements of the return acoustic signal arriving at the orthogonal transducer elements. Real world coordinates of the transponder are to be calculated by applying the range and bearing to the known real-world coordinates of the USBL transducer. The latter coordinates are computed through the measured offsets from the Common Reference Point (CRP) of the vessel and the application of simultaneous vessel heading, pitch and roll values. The accuracy of a USBL system decreases with range so it is important to check for (and remove) all transducer misalignment and range scale errors. A small angular misalignment of the USBL transducer head can translate to a significant positional error that increases with distance. Similarly an error in the range measurement will increase with distance without the application of an appropriate range scale correction factor. To find these errors, the USBL calibration is to be conducted in two stages by manoeuvring the vessel in a predetermined pattern around a known position transponder deployed close to the seabed. Preparation for Calibration A reference transponder will be deployed on to the seabed at a suitable location within or immediately adjacent to the survey area. Ideal sea conditions for the calibration of the USBL system are calm seas and slack tide (no current). At the chosen calibration location, the vessel will be as stationary as possible prior to deployment of the transponder. The transponder should be equipped with static release for easy retrieval upon the completion of the calibration. Also, a sufficient weight and flotation buoy should be used to ensure that the transponder is vertical and does not move during the calibration. It is necessary that the following operations should have been completed prior to the calibration: Verification of survey DGPS system. Application of a valid survey gyro correction. Measurement of VoS. Selection of calibration site in deeper water than the survey area. Removal of previous correction values from the USBL system.

The transponder will be deployed by the survey crew from a point on the vessel free of obstructions. The tidal drift and current will be considered prior to deployment so that the transponder is launched from the most favourable side/point of the vessel. There are two methods to conduct the dynamic USBL calibration. Calibration Method 1 The USBL calibration will be performed on arrival at site. This will be achieved by conducting the following two consecutive calibration stages: First stage, offset calibration and second stage, orientation calibration. The first stage is necessary to check that the measured offsets between the USBL transducer and the vessel common reference point (CRP) are accurate in the X, Y and Z axis. The first stage, also, calculates an accurate transponder position and depth to be used for the second calibration stage. The second stage is required to calculate the transducer pitch, roll and heading installation misalignments. Correction values for pitch and roll errors are to be obtained by comparing the angular misalignments between the transducer and the true horizontal and vertical planes. The orientation error, angular difference between the bow of the transducer and the vessels centreline, to be also obtained. Finally, a correction for range scale is to be found by comparing the actual transponder position with observations by the USBL system.
Page: 33 CP-SPE-0566A - Survey Quality Plan - Rev 0

Stage 1: Offset Calibration The calibration will be undertaken from the vessel positioned directly over the transponder recording its position on the seabed, either on fixed four headings or a variable heading where the ship rotates slowly through 360. During this check, a minimum of one hundred fixes will be recorded. This process will be conducted in both a clockwise, and anti clockwise direction. A maximum deviation off the initial position by 20 m should be maintained. USBL calibration software will then used to remove rogue USBL data points then iteratively reduce the data spread using least squares adjustment method. The accurate transponder position and the XYZ offset will be obtained by the software.

Diagram 8: Dynamic USBL Calibration, First Method, Stage 1

The calculated offsets will be compared with the known offsets from the vessel CRP to the USBL transducer. Also, the calculated transponder position will be used during the second stage of calibration. Stage 2: Orientation, Pitch, Roll and Range Scale Calibration The second stage is designed to detect and quantify pitch, roll, and horizontal alignment errors. The vessel will set up at four quadrants evenly distributed around the transponder. The vessel heading should remain the same for each point selected and as a general guide the transponder should be ahead, astern and a right angles to the vessels port and starboard sides during the data gathering. To achieve this, the best setup, is for the vessel to keep its head into the weather (preferred heading), and to calculate the quadrant positions from there, the horizontal range between the vessel and the transponder should be one and a half times the water depth. Fixes taken must be evenly distributed around the transponder. At least one hundred fixes will be logged per quadrant based on the sea, wind and current conditions.

Diagram 9: Dynamic USBL Calibration, First Method, Stage 2

Using the QINSy USBL calibration module, the logged data will be processed to solve for the following parameters in one least squares adjustment: X and Y position of the transponder; Pitch component (contains residual error in VRU pitch measurement plus transducer vertical misalignment); Roll component (contains residual error in VRU roll measurement plus transducer vertical misalignment); Heading component (contains residual error in the horizontal misalignment of the transducer plus the gyro deviation); Scale error; Standard deviation of the transponder position.

It is anticipated that any scale errors will almost exclusively be caused by incorrect determination of the VoS in the water column. The second stage will be repeated with the vessel setting up on the reciprocal heading.
Page: 34 CP-SPE-0566A - Survey Quality Plan - Rev 0

The quality of the calibration will be determined by examining the following parameters: Percentage of processed data passed (preferably above 70%); Derived Easting and Northing is within limits (5 m) of deployed position; Fixed range value below 5 metres; Standard deviation of Transducer Position (Tp) spread should be below 10 m, and the value after corrections applied smaller than before corrections applied; Range factor as close to 10 if possible.

Calibration Method 2 In this method, the vessel must be sailed around or across the transponder according to a predefined pattern to ensure balanced USBL data is obtained. To ensure that effect of time difference between surface navigation data and USBL data are kept to a minimum the vessel should be sailed slowly along its predefined course. The pattern to be sailed is centred on the position of the seabed USBL transponder. The point of closest approach of all the lines is to be approximately equivalent to the water depth. The lines start and end approximately 3 to 4 times the water depth away from the transponder. The orientation of the pattern is up to the vessel captain and survey crew to decide based on the sea and current conditions.
Diagram 10: Dynamic USBL Calibration, Second Method

Calibration Verification After corrections have been applied, a verification of the calibration is to be conducted by comparing realtime observations with the actual transponder position. A navigation line of length 200 m will be sailed at an offset of 50 m on either side of the transponder while simultaneously logging data. The line will be run for a second time in the opposite direction. Data will then processed and compared with the actual transponder position to check the positional accuracy of the USBL system and was to be within the acceptable limits. Note: Once the transponder is on the seabed, a surface position manual fix for the deployment point should be recorded by the surveyor. The deployment water depth should be also recorded. The USBL corrections should be set to zero within the USBL surface unit and the navigation software prior to the USBL calibrations.

Page: 35

CP-SPE-0566A - Survey Quality Plan - Rev 0

- MBES Calibration A MBES calibration shall be conducted prior to the commencement of survey operations. The following VoS Profile is to be carried out prior to the MBES calibration: In order to determine the Roll, Pitch and Heading corrections, QINSy survey software features a built in utility for MBES calibration patch tests. A patch test requires the following line configuration to be run: Latency:One line over an existing seabed feature, same direction but different survey speed. Roll: Two lines over a flat area in opposite direction. Pitch: Two lines over an area with slopes in opposite direction. Yaw: Two lines over an area with slopes and lines overlapping half the swath width.

Latency Test
To complete the latency test, one line will be surveyed in perpendicular to an existing seabed feature. The line will firstly be conducted at a speed of 2 knots. Then line will then be re-run at a speed of approximately 6 knots. If the vessel cannot manoeuvre /remain on line at 2 knots, run the minimum speed is to be attained. The second line must be run at 2 x first line speeds. A delay will be accurately detected up to 10 50 ms.

Roll Test
Two cross profiles will be obtained by performing two co-linear survey lines (both at standard survey speed approximately 4 knots) on reciprocal headings over a flat section of seabed close to the site, the deeper the seafloor, the more accurate the result; hence scout for the deeper are to conduct this calibration. If observed roll exceeds 5, then the MBES alignment and motion sensor calibration need to be checked. If different roll angle were observed for a number of line-sets, the motion sensor alignment needs to be checked.

Pitch Test
Two profiles will be obtained by performing two co-linear survey lines (both at standard survey speed) on reciprocal headings directly over an area with slope. If possible, a location should be chosen which has a slope over a relatively flat featureless seabed. In general the steeper the slope, the more accurate the determination of the pitch error will be. From the observations, if the pitch exceeds 10, then the MBES alignment and the motion sensor calibration needs to be checked. If a different roll angle is observed for a number of line-sets, then the motion sensor alignment needs to be checked.

Yaw Test
Two data sets will be obtained by performing two parallel, co-directional survey lines (both at standard survey speed, approximately 4 knots) with 25% overlap over an existing seabed feature.

Page: 36

CP-SPE-0566A - Survey Quality Plan - Rev 0

True/Grid Headings and Convergence Calculations

Diagram 11: Convergence Calculations

- Area / Line is West of Central Meridian For line AB, the magnitude of the line grid heading (angle) is greater than the magnitude of the line true heading (angle) by the convergence angle (C), refer to Diagram 11. Gangle > Tangle Gheading = Theading Convergence, where the convergence is ve to the west of Central Meridian. Then, the calculation of the grid heading relative to the true heading will be as follows: Gheading = Theading + Absolute Convergence Value - Area / Line is East of Central Meridian For line AB, the magnitude of the line grid heading (angle) is lesser than the magnitude of the line true heading (angle) by the convergence angle (C), refer to Diagram 11. Gangle < Tangle Gheading = Theading Convergence, where the convergence is +ve to the east of Central Meridian. Then, the calculation of the grid heading relative to the true heading will be as follows: Gheading = Theading - Absolute Convergence Value

Page: 37

CP-SPE-0566A - Survey Quality Plan - Rev 0

APPENDIX E PROCESSING OUTLINES

Page: 38

CP-SPE-0566A - Survey Quality Plan - Rev 0

Processing of Bathymetric Data During processing of bathymetric data the following checks shall be preformed: 1. Gross error check of the bathymetric data by means of comparison with water depths recorded during velocity profiles. 2. Draft measurements are correct for both frequencies in the SBES system. 3. Correct vessel offsets are applied to the corresponding sensors. 4. Data acquired by the SBES is matching in different directions and for different acquisition times. 5. Data acquired by the SBES is matching the data acquired by the MBES. 6. Data acquired on the current project matches data recorded on previous projects for the same area. Presented below are the main steps in which the bathymetry data is processed onboard the vessel: 1. Draft and Offset verification Verify the MBES and SBES drafts by actual draft measurement. Verify the MBES and SBES node location according to the vessel offset diagram. Conduct a bar check to verify the correctness of draft, sound velocity and other settings in the echo sounder units.

2. Sound Velocity Conduct regular sound velocity measurement by deploying CTD sensor twice a day during the survey. Enter correct sound velocity into the SBES and MBES units and provide a velocity profile cast for MBES processing. Verify correctness of sound velocity profile by looking at shape of MBES swath. Smiley shape will indicate possible incorrect sound velocity.

3. Tides Tidal predictions as per the tidal harmonic constituents for the survey area. Verify tide by overlaying crossed line which being surveyed in different time. Also verify the applied tides by manual applying tide into raw data.

4. Motion Sensors Verify the offsets and liver arms applied to motion sensors software. Verify correctness of motion sensors output by looking at the values in graphic mode and comparing existing motion sensors all together. Verify correctness of applied heave on SBES by comparing raw and heave applied single beam bathymetry and associated heave data. Verify correctness of applied pitch, roll and heave on MBES data by looking at swath and coverage of individual files and overlying on each other.

Page: 39

CP-SPE-0566A - Survey Quality Plan - Rev 0

APPENDIX F HORIZON SURVEY ORGANIZATION CHART

Page: 40

CP-SPE-0566A - Survey Quality Plan - Rev 0

Page: 41

CP-SPE-0566A - Survey Quality Plan - Rev 0

APPENDIX G QUALITY CONTROL

Page: 42

CP-SPE-0566A - Survey Quality Plan - Rev 0

Horizon Surveys Standard QC Check List Check ID A 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 B 01 02 03 04 05 06 07 08 09 10 11 12 Office - Preparation Stage Development of the notice of project award (NOPA) Contractual technical requirements handed to survey department Special client requirements handed to survey department Client supplied information and databases handed to survey department Project schedule handed to survey department Reporting schedule handed to survey department Development of Standards Quality Plan (SQP) Development and compilation of standard Field File (FF) QC Activity

Development & compilation of Field CD(s), this to include:


Standard survey subdirectory Project Daily Report (PDR), updated template Survey/calibration/verification forms and templates Land survey station descriptions and details Latest vessel diagram Client supplied information Latest HSC database and information Survey quality plan (SQP) Previous surveys within or nearby the project location Reporting templates and base chart Project blank field book(s) and relevant documents Carry out project briefing and issue the briefing form Offshore - Mobilisation Stage

Harbour checks and verifications:


Logbook compilation & update for offshore activities in detail PDR compilation & update for offshore activities Vessel offset diagram Draft measurements and pole markings Land survey observations Static DGPS health verification Gyro alignment calibration QINSy configuration Geodetic computation check Static USBL calibration Bar check Geophysical equipment and acquisition parameters setup

Page: 43

CP-SPE-0566A - Survey Quality Plan - Rev 0

Horizon Surveys Standard QC Check List Check ID 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 CTDS/TSDip SBES MBES SSS Chirp Pinger Sparker Magnetometer Sector scan QC Activity

Wet testing for geophysical equipment and spares:

Functionality checks for surface units:


SBES MBES Coda system Thermal Printers USBL unit Magnetometer unit Levelling and acquisition software (2D seismic surveys)

Functionality checks for heavy gear and spares:


Vessel Crane Small boat launching and recovery system ROV launching and recovery system (ROV surveys) SSS winch Magnetometer winch Coring winch Compressors (2D Seismic surveys) Air guns (2D Seismic surveys) Streamer winch (2D Seismic surveys)

Functionality and wet test for ROV surveys:


Thrusters Flotation system Cameras Depth sensors Heading sensor Sector scan Profilers Pipe tracker

Page: 44

CP-SPE-0566A - Survey Quality Plan - Rev 0

Horizon Surveys Standard QC Check List Check ID 46 47 48 49 50 51 52 53 54 55 56 57 C 01 02 03 04 05 06 07 08 09 10 11 12 D 01 02 03 04 E 01 Manipulator CP Meter Survey-bridge communication functionality check Graphic repeaters checks LAN communication and data speed checks Printers, digitizers and plotters check Consumables, oil, filters and spare parts check QC Activity

Checks and verifications before data acquisition:


Sea trials nearby the mobilization port using all sensors Dynamic DGPS verification Dynamic USBL calibration MBES calibration Updated and final QINSy configuration Offshore - Online QC Sound velocity casts to be run on 6 to 12 hours bases Draft measurement to be run on daily bases Draft measurement to be run after bunkering Compilation of survey line logs. Compilation engineering line logs. Compilation geophysical line logs.

The following end of line statistics to be recorded:


Minimum and maximum distance off-line Minimum and maximum number of satellites Minimum and maximum PDOP, HDOP & VDOP Minimum and maximum differential age Minimum and maximum feather angle (2D Seismic surveys) QC of the acquired geophysical data Offshore - Reporting Compilation of survey results report(s) Compilation of survey chart(s) Follow up and integration of 2D Seismic report(s) (2D Seismic surveys) Compilation of project operational report(s) Office - QC for Offshore Data Receive and check geophysical data samples

Page: 45

CP-SPE-0566A - Survey Quality Plan - Rev 0

Horizon Surveys Standard QC Check List Check ID 02 F 01 02 G 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 H 01 02 03 04 05 06 07 08 QC Activity Receive and check field and/or updated survey reports Office - Completion of Offshore Operations Carry out project de-briefing and issue the de-briefing form Upload all project data onto the companys main server Office - Reporting Completion of the remaining reporting (if applicable) Check the project, client, logos, revision, date details Check the geodetic, tidal and unit details Check the location map and all report attachments Review and check the vessel offset diagrams Review and check for the geophysical interpretation Review and check for the data examples Review and check for the field operations diary of events Review and check the equipment and personnel details Check the executive summary against the report contents Check for the grammar, spelling and standard formats

Check the report contents against the survey charts:


Project, client, logos, revision, scale, date and signature list. Geophysical interpretation Man-made feature coordinates and KPs Seabed feature coordinates and KPs Bathymetric information Geodetic information Tidal Information Final QC after the update of corrections/remarks Office - Charting & CAD Processing / reprocessing (if applicable) Check/Update base chart against CAD Standards Check P/F coordinates against client DB/HSC DB/previous surveys Update chart background from databases (client/previous surveys) Chart finalisation and plot for QC Final QC after the update of corrections/remarks Plotting of chart copies as per required by the PM Creating of PDF digital copy

Page: 46

CP-SPE-0566A - Survey Quality Plan - Rev 0

Horizon Surveys Standard QC Check List Check ID 09 10 I 01 02 03 04 05 06 07 08 09 J 01 02 03 04 K 01 02 03 04 Binding of the AutoCAD drawing file Cutting and folding of charts Office - Report Dispatch Report destination and contact list to be finalised & approved by PM Uploading the report pdf (including charts) onto share file web site Follow-up the client download and saving the download notifications Packaging of the report and chart hard copies (1) Issue of the hard copy transmittal note (2) Issue of the customer questioner form (3) Despatch the hard copies (1, 2 & 3) Follow-up the return of the signed transmittal note Follow-up the return of the customer satisfaction form Office - Continual Improvement Publication of the results of the customer satisfaction form Highlight the regions of non-conformities Corrective actions for the non-conformities (if exist) Update of this document Project QC Check List (if required) Office - Project Completion Storing the field file(s) and CDs Labelling and storing the raw data rolls and records. Cleaning and storing the project soft copy data on the server Distribution of updated check list and client reply on the customer questioner to different involved departments. QC Activity

Table 14: Horizon Surveys Standard QC Check List

Page: 47

CP-SPE-0566A - Survey Quality Plan - Rev 0

APPENDIX H HORIZON SURVEY CONTACT LISTING

Page: 48

CP-SPE-0566A - Survey Quality Plan - Rev 0

HSC Management Contact Details


Name Horizon Survey Position Main Office Office Tel. Office Fax Mobile Email Mobile Email Mobile Email Mobile Email Mobile Email Mobile Email Mobile Email Mobile Email Mobile Email Mobile Email Mobile Email Contact Details +971 6 557 3045 +971 6 557 3047 +971 50 558 4564 i.roberts@horizonsurvey.ae +971 50 633 4871 p.blackler@horizonsurvey.ae +971 50 462 8220 a.deyab@horizonsurvey.ae +971 50 4824 501 c.gray@horizonsurvey.ae +971 50 458 7131 s.pendse@horizonsurvey.ae +971 50 462 2768 h.ardalany@horizonsurvey.ae +971 50 633 5641 j.brindle@horizonsurvey.ae +971 50 769 4617 a.abdullathif@horizonsurvey.ae +971 50 266 7176 s.sharma@horizonsurvey.ae +971 50 504 8036 u.bell@horizonsurvey.ae +971 50 587 3716 m.heglan@horizonsurvey.ae

Ian Roberts

Managing Director

Peter Blackler

General Manager

Ashraf Deyab

Survey Manager

Colin Gray

Operations Manager

Saket Pendse

Engineering Manager

Hamid Ardalany

Project Manager

Jennifer Brindle

Asst. Project Manager

Abdulhy Abdullathif

Base Geophysicist

Sachin Sharma

Base Geophysicist

Ursula Bell

QC Surveyor

Mohammed Heglan

Senior Base Processor

Table 15: HSC Management Contact Details

Page: 49

CP-SPE-0566A - Survey Quality Plan - Rev 0

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 22 of 23

Attachment 7: PROJECT TIME SCHEDULE

Mattress Installation for Foroozan- Continual Of Supports Phase 12

ID 1

Task Name Mattress Installation for ForoozanContinual Of Supports Phase 12

Month 1 W-1 59.75 days 9.75 days

Duration

W1

W2

W3

Month 2 W4 W5

W6

W7

Month 3 W8 W9

Month 4 W10 W11 W12 W13 W14 Mattress Installation for Foroozan- Continual

2 3 4 5 6 7 8 20 21

Start Engineering Procurement End Of Support Installation sailing to first crossing point Matresses Ready In Field Installation of 53 mattresses Demob Finish

0 days 30 days 42 days 0 days 2 days 0 days 12.75 days 3 days 0 days

Start 30 days 42 days End Of Support Installation 2 days Matresses Ready In Field 12.75 days 3 days Finish Installation of 53 mattresses Demob sailing to first crossing point Engineering Procurement

Weather Down Time has been excluded

Rev 02

FOROOZAN Development Operations & Production Enhancement

Document Number
Crossing Installation Procedure For Export Pipeline
Project FE560 Facility GEXP Discipline PL Document PR Sequence 1727 Revision D0

Sheet NO. Page 23 of 23

Attachment 8: LIFTING FRAME ARRANGEMENT

Document No: FLX-IP-0029-05-2010-B Document Title:

Precast Concrete Mattress RIGGING/INSTALLATION PROCEDURE

A REV

06/12/10 DATE

Issued for client review DESCRIPTION

JD BY CHK CLIENT APP

Execution Plan TABLE OF CONTENTS


1.0 INTRODUCTION ..........................................................................................................................2 2.0 REFERENCES ................................................................................................................................2
2.1 APPLICABLE CODES AND STANDARDS .............................................................................................................................. 2 2.2 IGO INTERNAL SAFETY TESTING DOCUMENTS............................................................................................................ 2 2.3 SPECIFIC CERTIFICATION DOCUMENTS............................................................................................................................ 2

3.0 INSTALLATION FRAMES ............................................................................................................3


3.1 HEADER FRAME .............................................................................................................................................................................. 3 3.2 RELEASE BEAMS.............................................................................................................................................................................. 3 3.3 TYPES OF INSTALLATION FRAMES ....................................................................................................................................... 4 3.4 MATTRESS AND FRAME ASSEMBLY....................................................................................................................................... 5

4.0 CERTIFICATION REQUIREMENTS .........................................................................................5 5.0 PROJECT SUPPLIED INSTALLATION FRAME .......................................................................5 6.0 FLXMAT HANDLING PROCEDURE .........................................................................................6
6.1 PRE-EXECUTION ACTIVITES .................................................................................................................................................... 6 6.2 RIGGING THE INSTALLATION FRAME ............................................................................................................................... 6 6.3 DE-RIGGING THE INSTALLATION FRAME ....................................................................................................................... 7 6.4 INSTALLING MATTRESSES SUBSEA ....................................................................................................................................... 8 6.5 SAFETY REQUIREMENTS ............................................................................................................................................................ 9 6.6 FLXMAT WEIGHING PROCEDURE ......................................................................................................................................... 9

7.0 INSTALLATION FRAME DELIVERABLES ...............................................................................9

Page:1

Execution Plan
1.0 INTRODUCTION The purpose of this document is to provide International Grout and client with a suitable procedure to safely handle FLXMAT precast concrete mattresses. Mattresses are lifted, loaded and stacked a number of times prior to installation hence the importance of maintaining a consistent safe lifting practice. 2.0 REFERENCES 2.1 APPLICABLE CODES AND STANDARDS The following standards are followed to ensure a safe and suitable lift is achieved onshore and offshore. Code or Standard DNV Pt 2 Ch 5&6 BS EN12079-1999 DAC 2006, LOLER 1998 and Article (20) decree 32, 1982 (local U.A.E law). Title DNV Rules for Planning and Execution of Marine Operations (1996) Offshore containers. Design, construction, testing, inspection and marking Accreditation requirements of inspection Bodies for lifting equipment. Remark Required for the design of FLXMAT lifting points.

2.2 IGO INTERNAL SAFETY TESTING DOCUMENTS The following documents are refer a minimum requirement IGO adhere to for any Offshore piece of equipment intended for Oil Field use. IGO Documentation IGO Annual Programme for Safety Testing Description IGO Offshore Equipment Remark

2.3 SPECIFIC CERTIFICATION DOCUMENTS The following certification will be consolidated and submitted to the Client just prior to delivery or rental of each suitable installation frame. Certification Polypropylene Mill Test Certificate Description Certificate that proves a specific rope diameter Minimum Breaking Load (MBL) Calculation to verify lifting point conform to DNV Rules for Planning and Execution of Marine Operations (1996) Part 2 Ch 5/6

Remark Required to ensure FLXMAT lifting rope conform to DNV Pt2, Ch5

IGO Lift Rope Verification

Page:2

Execution Plan
Proof Load (PL) Test Certificate Visual Inspection (VI) Report (Installation Frame) Visual Inspection Report (Rigging) 3.0 INSTALLATION FRAMES 3.1 HEADER FRAME The header frame is the structural part of the lift comprising of 4 padeyes and two main longitudinal members. The longitudinal members are designed for both end and side lift applications. End lift lug Padeye location connectors Non Destructive Test (NDT) to prove structures integrity and design. Also includes wire sling test certificate. Overall Visual Inspection to check frame is in correct working order. Also includes wire sling visual inspection report. Overall Visual Inspection to check rigging is in correct working order. Witnessed by 3rd Party certification body Conducted by 3rd Party Inspector Conducted by 3rd Party Inspector

Side lift lug connectors

3.2 RELEASE BEAMS Release beams are interchangeable sections that enable the header frame to lift either a side or end lift mattress. They are designed for ROV and Diver release subsea. The release beam is activated by an open/close lever. The lever is always situated on the corners of the header frame. Open/Close lever Pin and Guide assembly

Lower bolt/lug point

Page:3

Execution Plan
3.3 TYPES OF INSTALLATION FRAMES International Grout have an array of Installation Frames suitable for almost any mattress sizes requested. Installation frames are best broken into two categories. End Lift Release beam located either end

Release beam bolted to each end

Side Lift Release beam located along each side

2No. Release beams bolted to each side

Page:4

Execution Plan
3.4 MATTRESS AND FRAME ASSEMBLY Below pictures represent the distinct difference between an End Lift and Side Lift scenario.

Above End Lift 4.0 CERTIFICATION REQUIREMENTS

Above Side Lift

The below table outlines International Grout company standard for testing and inspecting offshore installation frames. (KEY: Y-Years, M-Months) ITEM Proof Load Test Visual Inspection (Frame) Visual Inspection (Rigging) Frequency 6Y 4Y 6M

5.0 PROJECT SUPPLIED INSTALLATION FRAME The following table represents the physical details of the designated frame(s) to be mobilized for this project. Equip. ID LPF007 End/Side Lift SIDE Total Length 6m Total Width 3m

Mattress/Frame GA Drawing: 0029-05-2010B-DWG-051210-01

Page:5

Execution Plan
6.0 FLXMAT HANDLING PROCEDURE 6.1 PRE-EXECUTION ACTIVITES Prior to any lift the IGO supervisor must check with the IGO Engineer that the piece is equipment is been used for the correct application. Additionally, the supervisor must check with the equipment manager that all certification is in line with Section 4.0 of this procedure. The final assembly must be in accordance to the drawing stated in Section 5.0. All cranes must be specified within their working limit. 6.2 RIGGING THE INSTALLATION FRAME 1. The selected frame is connected to crane hook via oblong link and 4 legged wire sling. Rigging Supervisor instructs crane operator to lower and place frame directly above mattress intended for relocation.

2. Once the frame comes to rest rigging personnel assist by connecting mattress lifting rope to installation frame. One end of a flat eye webbing sling is permanently fixed to the bottom lugs of the beam. The other end is threaded through the opening of the mattress and looped into the pin and guide assembly. The lever is pushed into the closed position so that all points are contained within the pin and guide assembly.

Page:6

Execution Plan
3. All points should be doubled checked prior to giving the crane operator instructions to commence lifting the mattress. Tag lines should be place on two opposing corners to help control orientation once the mattress leaves the ground. All personnel not required for relocating the mattress should stay well clear of the task at hand. Rigging personnel are prohibited from entering directly beneath a live load under any circumstance.

6.3 DE-RIGGING THE INSTALLATION FRAME 4. When placing the mattress, the supervisor and crane operator communicate until a satisfactory position is achieved. The mattress and frame are lowered together until all webbing slings become loose. Rigging personnel open the lever release and ensure each webbing eye is completely clear from the release beam.

Page:7

Execution Plan
5. The crane operator slowly lifts the frame. The supervisor and rigging personnel watch closely to make sure the webbing slings do not snag or catch as frame pulls away from the mattress. If snap hooks are used as opposed to the lever system care must always be taken that each link is connected and disconnected when intended.

6.4 INSTALLING MATTRESSES SUBSEA 1. Steps 1-3 of Section 6.2 shall be followed offshore when rigging installation frame on deck. Rigging team should additionally check that safety pin is engaged prior to over boarding each mattress. The safety pin ensures that the release beams cannot become loose at any stage of the installation. 2. Frame shall have two locating beacons (one at each end) to aid placing the frame subsea. Beacons should be place well inside frame exterior in case of impact during over boarding and recovery. 3. The lever on each corner shall have a floating monkeys fist to assist ROV/diver locating and pulling lever when the time comes. Once the installation team correctly place the mattress at the intended location the ROV/Diver is instructed to open the safety pin and release the mattress. 4. ROV/Diver must check that all webbing slings are loose with no weight acting on them before given approval to commence recovery. As the frame slowly pull away from the mattress the ROV/Diver must constantly monitor that the webbing slings are clear of all obstructions and potential snagging points. 5. The frame is recovered and placed on the next mattress for installation and the process continues.

Page:8

Execution Plan
6.5 SAFETY REQUIREMENTS All personnel shall attend any required site induction program to become familiar with the site and client method of operation. Personnel shall comply with all client rules and regulations. Company equipment includes a comprehensive first aid kit. Personnel will be briefed during the initial site induction on the hazards of handling FLXMAT. The IGO supervisor will be responsible for site safety and conduct regular toolbox meetings with all personnel. The following PPE (Personal Protective Equipment) is required for handling concrete mattresses. Activity FLXMAT Handling Minimum PPE Requirement Covered steel capped boots, eye protection, coveralls, gloves and sun protection, gloves and hardhat

6.6 FLXMAT WEIGHING PROCEDURE At the time of moving or loading out FLXMAT the crane which has a computerised load cell will record the individual weight of each mattress lifted. For instances where crane does not have accurate load cell and external dedicated load cell will be installed between the lifting hook and slings master link to record mattress weights. Each mattress serial number including weight will be tabulated in a report and included within the Manufacturer Record Book (MRB). 7.0 INSTALLATION FRAME DELIVERABLES The following documents are included within the Manufacturer Record Book (MBR) Manufacturer Record Book 4.0 FLXMAT Rigging and Installation Procedure 5.0 Installation Frame Certification 5.1 Proof Load Test Certificate (Frame and Wire Sling) 5.2 Visual Inspection (Frame and Wire Sling) 5.3 Visual Inspection (Rigging Soft Slings) Info Info Info Approved Final

Page:9

You might also like