Design Wind Force Calculation

Design Wind Speed Height above Ground Level, z Exposure Category Velocity Pressure coefficient, Kz Structure Class Topographic Category Crest height , H Topographic Factor, Kzt Directionality Factor, Kd Importance Factor Velocity Pressure, qz EPA Calculation of Tubular Pole Gust Effect Factor Structure Height Pole Outside diameter, D C value Force Coefficient, Cf Area of Pole, Ap EPA Design Wind Force, Fst Design Wind Force/m run EPA Calculation of Appurtances (Flat Panel) Antenna Name Wind Angle Antenna Dimensions Length ,L Width, w Depth, d EPA Calculation Ka Aspect Ratio, (L/w) Aspect Ratio, (L/d) (Ca)n (Ca)t (EPA)n (EPA)t (EPA)a Design Wind Force, Fa EPA Calculation of Microwave Antennas Antenna Name MW0.6 160 26 C 1.22 II 1 0 1.00 0.85 1 1.26 KPh m

Kpa

0.85 6 0.088 4.33 1.20 0.528 0.63 0.68 0.11

m m

m2 m2 kN KN/m

GSM 2G 0 2.45 0.37 0.106 1 6.62 23.11 1.38 1.94 1.25 0.50 1.254 1.34

Deg m m m

0.00 Radians

m2 m2 m2 KN

Outside Diameter of Microwave Area of Aperture, A Wind Angle Ca Cs Cm Design Wind Force FAM FSM MM EPA Calculation of Feeder Cables Wind Angle Ka Cable Diameter Total No Cables No of Rows Cables/ row Clear spacing between cables Clear spacing between rows EPA considering Individual lines/m run (EPA)n considering Equ. Rect Appurtenance/m run (EPA)t considering Equ. Rect Appurtenance/m run (EPA)a EPA Cables Design Wind force/m run, Fs

0.675 0.358 0 1.5508 0 0 0.59 0 0

m m2 Deg
* Input Ca, Cs and Cm based on type of Antenna and wind angle From Table C1 -C4, TIA 222G

kN kN KNm

0 1 30 18 3 6 30 30 0.648 0.33 0.15 0.33 0.33 0.35

Deg mm

0.00 Radians

mm mm m2 m2 m2

KN/m

Exposure Category B C D Topographic Category 1 2 3 4 Structure Class I II III 1.2

Zg 366 274 213 Kt 0.43 0.53 0.72 Importance Factor Wind 0.87 1 1.15

7 9.5 11.5 f 1.25 2 1.5

Kzmin 0.7 0.85 1.03 Kh #DIV/0! #DIV/0! #DIV/0!

Ke 0.9 1 1.1 Kzt 1 #DIV/0! #DIV/0! #DIV/0!

d on type of Antenna

le C1 -C4, TIA 222G

1.224262 1.224262 1.224262

Design of Tubular Pole structures Subjected to Axial, Moment, Shear and Torsion Input Loads Factored Axial Load, Pu Factored Moment, Mu Factored Shear, Vu Factored Torsion, Tu Properties of Section Outer Diameter of Pole, D Thickness, t Inner Diameter, d Modulus of Elasticity, E Yield Strength, Fy Area, A Elastic Section modulus, S Plastic Section modulus, Z Polar Moment of Inertia, J Calculation for Compressive Strength D/t Effective yield strength Compressive Strength, Pn Calculation for Flexural Strength Moment Strength, Mn Calculation for Shear Strength Shear Strength, Vn Calculation for Torsional Strength Torsional Strength, Tn Check For Interaction 10.64 Unsafe

19 16 20 2

KN KNm KN KNm

42 5 32 2.00E+05 275 580.9 4822.53 6886.67 202546.3324

mm mm MPa Mpa mm2 mm3 mm3

8.40 275.00 135.79

Mpa kN

1.70

kNm

71.89

KN

2.39

KNm

Design of Tubular leg members subjected to compression for latticed structures


Input Data Factored Axial Compression Unsupported Length Properties of Section Outer Diameter of Pole, D Thickness, t Inner Diameter, d Modulus of Elasticity, E Yield Strength, Fy Calculation Area, A D/t Effective yield strength K Moment of Inertia, I Radius of Gyration, r Slenderness ratio, KL/r c Fcr Allowable Compressive Strength Ratio 200 400 42 5 32 200000 275 581.19 8.4 275.00 1 101273.17 13.20 30.30 0.36 260.66 128.77 1.55 kN mm mm mm mm Mpa Mpa mm2 Mpa mm4 mm

Mpa kN Unsafe, Revise section

Design of Tubular members subjected to axial compression and bending forces for Latticed Structures
Input Data Factored Axial Compression Factored Moment Unsupported Length Member Type P-Delta Effects Considered Properties of Section Outer Diameter of Pole, D Thickness, t Inner Diameter, d Modulus of Elasticity, E Yield Strength, Fy Elastic Section modulus, S Plastic Section modulus, Z Moment of Inertia, I Radius of Gyration, r Calculation Area, A D/t Effective yield strength K Slenderness ratio, KL/r c Fcr Allowable Compressive Strength Allowable Moment Strength Check for Interaction Pu/Pn B1 Amplified Factored Moment, Mu Interaction 100 0.1 200 Leg No 42 5 32 200000 248 4822.53 6886.67 101273.17 13.20 581.19 8.40 248.00 1 15.15 0.17 245.02 121.05 1.54 0.83 0.87 0.09 0.78 kN KNm mm

mm mm mm Mpa Mpa mm3 mm3 mm4 mm mm2 Mpa


* Input K value from Table 4.3 to Table 4.5 based on Member type and End conditions.

Mpa kN kNm

Safe

Minimum Bracing Resistance Check Unsupported Length K value radius of gyration Axial Design compressive force in supported member Slenderness ratio, KL/r Minimum Bracing resistance, Ps 515 0.7 3 100 120.17 2.50 mm mm KN kN

2.50