DuPont Refrigerants

U.S. GENERAL REPLACEMENT GUIDE

RECOMMENDED R-22 REPLACEMENTS*


ISCEON MO99

R-438A

ISCEON MO29

R-422D Retrofit

Suva 407A

Suva 407C

R-407A

R-407C

Suva 410A

R-410A

Retrofit

HFC

HFC

New Equipment Retrofit

HFC

New Equipment Retrofit

HFC

New Equipment Only Designed for R-410A

HFC

Lubricant
MO AB POE

Lubricant
MO AB POE

Lubricant
POE

Lubricant
POE

Lubricant
POE

Evaporator Temp
High Medium Low

Evaporator Temp
Medium Low

Evaporator Temp
Medium Low

Evaporator Temp
High

Evaporator Temp
High Medium

Applications
AC: Commercial Lt Commercial Refrigeration: Commercial Industrial

Applications
Refrigeration: Commercial Industrial

Applications
Refrigeration: Commercial Industrial

Applications
AC: Commercial Residential Refrigeration: Commercial

Applications
AC: Commercial Heat Pumps Residential

R-12, Suva MP39, MP66, R409A REPLACEMENTS*


ISCEON MO49Plus

R-503, R-13 REPLACEMENTS*


Suva 95

ISCEON 39TC

R-423A

Suva 134a

R-134a

R-508B

Freon 23

R-23

R-437A

Retrofit

HFC

Retrofit

HFC

New Equipment Retrofit POE PAG (auto AC)

HFC

New Equipment Retrofit (for R-503)

PFC

New Equipment Retrofit (for R-13)

HFC

Lubricant Lubricant
MO AB POE POE
single lubricant change

Lubricant

Lubricant
POE

Lubricant
POE

Evaporator Temp
High Medium

Evaporator Temp
Medium Low

Very Low Temp (VLT) Very Low Temp (VLT) High Below -40F Below -40F Medium (Above +20F /-7C)

Evaporator Temp

Evaporator Temp

Evaporator Temp

Applications
Centrifugal Chillers

Applications
Commercial Refrigeration: Appliances Chillers Automotive AC

Applications
Refrigeration:
Cascade Systems

Applications
Refrigeration:
Cascade Systems

Applications
Refrigeration: Commercial Industrial

*For more detailed information on DuPont Refrigerants and their applications, please visit www.refrigerants.dupont.com and/or www.isceon.com.

SUG G E ST E D O I L G U I D E
ISCEON Refrigerant

Recommended Lubricant MO MO MO MO MO POE


(single lubricant change)

Alternate Lubricant AB - POE AB - POE AB - POE AB - POE AB - POE

Suva Refrigerant

Recommended Lubricant POE MO POE/PAG


(Auto AC)

Alternate Lubricant AB

ISCEON MO99 (R-438A)


Suva 95 (R-508B)

ISCEON MO79 (R-422A)

Suva 123

ISCEON MO59 (R-417A)

Suva 134a

ISCEON MO49Plus (R-437A)


Suva 404A

POE POE POE POE POE

ISCEON MO29 (R-422D)

Suva 407A

ISCEON 39TC (R-423A)


Suva 407C

Suva 410A

ISCEON Refrigerants - Oil Change Guidelines

Suva 507

ISCEON Refrigerants are compatible with traditional and new lubricants mineral oil, alkylbenzene and polyol ester. In systems where oil return is a potential concern, replacement of all, or part (10~25%) of the compressor oil charge with an OEM approved polyol ester is recommended. ISCEON 39TC requires one lubricant change to POE during retrofit. ISCEON 39TC tolerates high residual levels of mineral oil; therefore no system flushing is required after changing the original lubricant to POE.

Suva Refrigerants - Oil Change Guidelines

Where possible, use OEM-recommended oil type, charge size, and viscosity. hen converting a CFC or HCFC system to an HFC W refrigerant such as Suva 134a, 407C or 407A, POE is the recommended lubricant. At least 95% of the MO or AB should be replaced with POE of similar viscosity. This typically requires multiple oil changes.

MO = Mineral Oil AB = Alkylbenzene POE = Polyol Ester

Performance Comparison of Retrofit Refrigerants


Refrigerant R-22 HFC Replacements ISCEON MO99

Compared to LT* R-22 R-22 R-22 R-22 R-22 R-502 R-502 R-502 +28 +23 +21 +29 +3 +10

Discharge Pressure (psi) MT** +6 +12 -23 +19 +35 +30 +27 +36 -20 +18 same -32 -20 -22 HT*** +5 LT* -22 -31

Discharge Temp (F) MT** -45 -66 -62 -29 -36 -19 -10 -12 -40 -18 -1 -1 +1 +2 HT*** -31 LT* -6 -3

Est. Cooling Capacity (%) MT** -8 -6 -17 -4 +2 -6 +1 +2 -17 -1 +1 -4 -2 -2 HT*** -7 LT* +7 +8

Est EER (%) MT** -1 -4 -2 -1 -4 -8 -3 -3 -1 -2 HT*** -2

ISCEON MO29

ISCEON MO59

Suva 407C

Suva 407A

R-502 HFC Replacements ISCEON MO79

Suva 404A

Suva 507

*Low Temperature: -25F evaporator, 105F condenser, 65F return gas, 10F subcooling **Medium Temperature: 20F evaporator, 120F condenser, 65 F return gas, 10F subcooling ***High Temperature: 45F evaporator, 115F condenser, 65 F return gas, 10F subcooling R-22 assumes demand cooling with discharge temp of 275F

Refrigerant ISCEON 39TC


Compared to R-12

Discharge Pressure (psi) Same +30 to +39 +10 +2 -26 -41

Discharge Temp (F) -20 -28 to -16 -10 -40 +53 -27

Est. Cooling Capacity (%) 0 to -5 +4 to +10 -15* -2 -26 -29

Est EER (%)

R-12 HFC Replacements Chillers ISCEON MO49Plus Suva 134a

R-12 R-12 R-503 R-503 R-503

-3 to -4

R-503, R-13 Replacements Suva 95

Freon 23

Freon 23

Performance data based on normal application conditions and is intended to serve as a guide; actual performance will vary depending on system design and conditions. + is increase - is decrease *Capacity loss can be determined by performing an engineered retrofit. Contact DuPont for details.

PRE S S U R E C O N T RO L S E TT I NGS GUIDE (approximate) SUPERMARKET REFRIGERATION RETROFITS


This pressure control setting guide provides you with approximate settings that can be used as starting points to help you optimize your system. Recognize that the values expressed can vary with specific conditions, such as actual relative humidity, pressure drop, line sets, equipment location and design. If your current settings for R-22 vary from the baseline values given below, the alternative refrigerant settings will vary proportionally. For more information on retrofits, go to www.refrigerants.dupont.com
Application Temp Range (F) 35 to 38 32 to 35 Evap (F) 15 R-22 Out Beverage Cooler Floral Cooler Produce Cooler Smoked Meat Cooler Meat Reach Thru Service Deli Seafood Multi-Deck Fresh Meat Frozen Glass Door Frozen Glass Walk-In Frozen Ice Cream Frozen Food - Open Type 26 to 29 -10 to 0 -30 to -20 15 10 10 32 9 0 54 24 10 29 7 4 in Hg 51 21 8 33 9 0 56 23 10 42 14 4 69 32 15 42 15 4 68 33 16 45 16 5 72 35 18 47 37 6 76 48 20 40 31 3 65 41 15 15 38 62 35 59 39 64 49 77 49 77 52 82 55 86 47 73 41 In 66 ISCEON MO99

Refrigerant (psig) ISCEON MO29 Out 42

ISCEON MO79 Out 52

R-404A Out 53 In 82

R-507 Out 56 In 86

HP80 (R-402A) Out 59 In 91

R-502 Out 50 In 78

Out 38

In 63

In 69

In 82

GEN E R A L R E T RO F I T G U I D E
For detailed information, please see our retrofit guidelines at www.refrigerants.dupont.com and/or www.isceon.com.
Record baseline data. Power OFF system.

*Recover refrigerant from system and weigh amount removed.

Easy Retrofit to ISCEON Refrigerants. No Oil Change.

Retrofit examplesno oil change R-12 to ISCEON MO49Plus R-22 to ISCEON MO99, MO59, MO29 R-502 to ISCEON MO79

Replace filter/drier and critical seals

Evacuate system to 500 microns and check for leaks.

Charge with ISCEON refrigerant. Remove as liquid only from cylinder.

Start system, make adjustments. DO NOT overcharge (90-95%)

Monitor oil level. Top up with AB or MO. Add POE if required.

Label system.

*For retrofit to HFC multiple oil changes, DO NOT remove CFC or HCFC refrigerants until AFTER oil flushing is complete.

DuPont Refrigerants
U.S. GENERAL REPLACEMENT GUIDE

R-502, Suva HP80, HP81, R-408A REPLACEMENTS*

R-11 REPLACEMENTS*
Suva 123

ISCEON MO79

R-422A

Suva 404A

R-404A

Suva 507

R-507

R-123

Retrofit

HFC

New Equipment

HFC

New Equipment

HFC

New Equipment Retrofit

HCFC

Lubricant
MO AB POE

Lubricant
POE

Lubricant
POE

Lubricant
MO

Evaporator Temp
Medium Low

Evaporator Temp
Medium Low

Evaporator Temp
Medium Low

Evaporator Temp
High Medium

Applications
Refrigeration: Commercial Industrial

Applications
Refrigeration: Commercial Industrial

Applications
Refrigeration: Commercial Industrial

Applications
Centrifugal Chillers

*For more detailed information on DuPont Refrigerants and their applications, please visit www.refrigerants.dupont.com and/or www.isceon.com.

DuPont Refrigerants. The Science of Cool.


www.refrigerants.dupont.com www.isceon.com
DuPont Refrigerants Chestnut Run Plaza 705-GS29 P.O. Box 80705 Wilmington, DE 19880-0705 U.S.: 1-800-235-7882 Canada: 1-800-873-7882

TM

Copyright 1997-2011 DuPont. All rights reserved. The DuPont Oval Logo, DuPont , The miracles of science , The Science of Cool , ISCEON and Suva are registered trademarks or trademarks of E. I. duPont de Nemours and Company or its affiliates. No part of this material may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, mechanical, photocopying, recording without the permission of DuPont. (1/11) [Replaces H-71061-13] Reorder No: H-71061-14

You might also like