This document provides the results of a blind thickness calculation for a pipe. The test pressure was 3 bar.g on a 42-inch pipe. The calculated minimum required blind thickness without a stiffener is 19.85 mm, based on the equations in ASME B31.3 Paragraph 304.
This document provides the results of a blind thickness calculation for a pipe. The test pressure was 3 bar.g on a 42-inch pipe. The calculated minimum required blind thickness without a stiffener is 19.85 mm, based on the equations in ASME B31.3 Paragraph 304.