PASOLINK/PASOLINK+ Maintenance Quick Reference

Rev. 02 : 2003.September

NEC Corporation

PASOLINK Maintenance Quick Reference

Table of Content
1 1.1 1.2 2 INTRODUCTION ........................................................................................................... 1 Purpose ....................................................................................................................................1 Reference Manuals..................................................................................................................1 MAINTENANCE SERVICE OVERVIEW ....................................................................... 2 2.1.1 2.1.2 2.1.3 3 3.1 3.2 Service Summary ..............................................................................................................2 Precautions........................................................................................................................2 Test Equipment .................................................................................................................2

PREVENTIVE MAINTENANCE .................................................................................... 3 Frequency of Preventive Maintenance..................................................................................3 Preventive Maintenance Procedures .....................................................................................4 Radio Equipment ..............................................................................................................4 Aerial Equipment ..............................................................................................................6 Interface Cables and Connectors.......................................................................................7

3.2.1 3.2.2 3.2.3 3.3 4 4.1

Preventive Maintenance Flowchart.......................................................................................8 CORRECTIVE MAINTENANCE.................................................................................... 9 Corrective Maintenance Procedures .....................................................................................9 Radio Equipment ..............................................................................................................9 Aerial Equipment ............................................................................................................13 Interface Cables and Connectors.....................................................................................14

4.1.1 4.1.2 4.1.3 4.2 4.3

Corrective Maintenance Flowchart.....................................................................................15 List of Alarms ........................................................................................................................16

APPENDIX A PREVENTIVE MAINTENANCE CHECKLIST............................................. 34 APPENDIX B SITE INVENTORY DATA RECORD SHEET............................................... 39

NEC Corporation

PASOLINK Maintenance Quick Reference

Introduction
1.1 Purpose
This document is designed as a quick reference guide for maintenance service of the PASOLINK/PASOLINK+ system.

1.2

Reference Manuals
The following list of manuals is recommended to be referenced during maintenance of the PASOLINK equipment.

No. 1 2 3 4 5

Title PASOLINK Installation Manual (1+0 System) PASOLINK Instruction Manual PASOLINK+ Instruction Manual (1+0/1+1 System) Pasolink Network Management Terminal Operation Manual Pasolink Network Management System Operation Manual, WindowsNT Version

Manual No. ROI-S03508 ROI-S04614 ROI-S04755 ROI- S04060 ROI-S04067

NEC Corporation

PASOLINK Maintenance Quick Reference

Maintenance Overview
2.1.1 Summary
There are two types of Maintenance defined in the PASOLINK/ PASOLINK+ system, namely, preventive (periodic) maintenance and corrective maintenance. The customer is recommended to perform preventive maintenance according to the instruction in Chapter 3 Preventive Maintenance of this manual. Upon discovery of fault in the system, the customer should follow the corrective maintenance procedures detailed in Chapter 4 Corrective Maintenance of this document.

2.1.2

Precautions
Danger: Around 43V DC power (Depends on IF cable length) is superimposed on the center conductor of the coaxial cable between the IDU and ODU. Connecting a measurement set may damage that set. Touching the coaxial cable core may cause electrical shock. Caution: To protect the internal circuits against electrostatic discharge, engineers are requested to wear the wristband and connect it to the frame ground for Electrostatic Protection (ESP) before detaching the top cover. (a) Before beginning maintenance, notify the opposite station that maintenance is about to begin. (b) After equipment starts-up, allow the equipment to warm up for at least 30 minutes. (c) During maintenance, set the IDU to maintenance mode using a PNMT according to the user manual. (d) After completing the maintenance operation, restore all connections to normal.

2.1.3

Test Equipment
The test equipment and special accessories described in Table A are required for system maintenance. If recommended test equipment and accessories are not available, equivalents may be used.

Table-A Test Equipment and Accessories Required


Test Equipment/Accessory Headset Personal Computer (PC) with RS-232C cable for IDU Touch-up paint Remarks PNMT software installed For antenna Qty Reqd 1 each 1 set 1 set

NEC Corporation

PASOLINK Maintenance Quick Reference

Torque wrench, spanner, screwdrivers, tape, vinyl tape Self bounding tape, vinyl tape

For fixing point For waterproof treatment

1 set 1 set

Preventive Maintenance
This section describes the maintenance work that should be performed on a periodical basis in order to maintain the system at its highest quality. It should be performed by fully qualified personnel to ensure proper performance of the system and safety at the operation site.

3.1

Frequency of Preventive Maintenance


To ensure continuously satisfactory operation of the system, perform the preventive maintenance on a timely basis recommended as follows. 1st: Three (3) months after the start of operation. 2nd: Twelve (12) months after the start of operation. 3rd and after: Every one (1) year. The customer is recommended to make use of Preventive Maintenance Checklist from Appendix A of this document for recording purpose.

NEC Corporation

PASOLINK Maintenance Quick Reference

3.2

Preventive Maintenance Procedures


Radio Equipment
1. Visual inspection. Visually inspect ODU and IDU for surface damage or abnormal appearance and check looseness of bolts and nuts. Visually inspect ODU and IDU for surface damage or abnormal appearance and check looseness of bolts and nuts. 2. Meter reading a-1) Connect the PNM Terminal (PC) to the LA PORT of the IDU using RS-232C cable. (In case on PASOLINK) a-2) Connect the PNM Terminal (PC) to the PNMT PORT of the IDU using RS-232C cable. (In case on PASOLINK) b) Set the PNMT to show ODU monitoring data according to the procedure in the PNMT user manual. c) When the system is in normal working condition, result shall be the values shown in Table B below.

3.2.1

Table. B Meter Reading from IDU (PASOLINK V3)


Check Item ODU primary power supply voltage Transmitter Power Receiving Level Allowable Range 3:5 to 4.5V DC (35 to 45V DC) (Depending on cable length between ODU and IDU) 0 to 4.6 V DC Relative to the recorded value in the site inventory data record (see Appendix B) 0.2 to 4.5V DC (depending on received signal level)

Table. C Meter Reading from IDU (PASOLINK V4)


Check Item Transmitter Power Receiving Level Allowable Range +0 to 4.6 V DC Relative to the recorded value in the site inventory data record (see Appendix B) 0.8 to 4.4V DC (depending on received signal level)

Table. D Meter Reading from IDU (PASOLINK+)

NEC Corporation

PASOLINK Maintenance Quick Reference

3. Check configurations a) Check the condition setting of the IDU according to the procedure in the PNMT user's manual. b) Confirm if the condition setting is appropriate according to the site inventory data. c) The latest configuration file shall be uploaded and stored. Also, the Equipment Configuration Parameter shall be recorded and filed as site inventory data record. Note: A copy of Site Inventory Data Record sheet is provided in Appendix B.

NEC Corporation

PASOLINK Maintenance Quick Reference

3.2.2

Aerial Equipment
1. At first perform visual inspection. Visually inspect antenna and associated mounting structures and Hybrid Combiner (if applicable) for surface damage or abnormal appearance. 2. Check for loose bolt connections. Make sure that all bolts and nuts are tightened to the specified torque. 3. Rust prevention a) Repainting should be carried out every two years to maintain high corrosion resistance and appearance of the antenna. However the period may change if rusting or exfoliation occurs earlier. b) For antenna, clean first by removing oil and dirt completely with solvent and then washing with water. Then apply top coat with ally alkyd enamel diffusive paint (belcoat No.5500) or equivalent. c) For hot dip galvanized parts of the steel structure, first completely remove rust, dirt, etc. on the position causing exfoliation of plating. Then apply Amercoat No.160 with a brush or sprayer (Thickness: more than 70 microns) manufactured by Amercoat (AMERCOAT EUROPE). Note that more than 70 microns is roughly amount to one (1) or two (2) times of paint brushing, or two (2) or three (3) times of paint spraying.

NEC Corporation

PASOLINK Maintenance Quick Reference

3.2.3

Interface Cables and Connectors


1. At first perform visual inspection. Visually inspect the following items for surface damage or abnormal appearance. i) ii) iii) iv) v) vi) vii) viii) ix) x) The connectors of jumper cable between ODU and IDU Jumper cables Frame ground of ODU Grounding of feeder IF cable connector Power supply cable and connector Traffic IN/OUT cable and connectors Alarm cable and connectors Service Channel cables and connector NMS cable and connector

2. Check for loose bolt connections. Make sure that the jumper coaxial cables between ODU and IDU are firmly fixed, and all bolts and nuts are tightened. 3. Check waterproof treatment. Check if waterproof treatment is in good condition on connection point of the jumper coaxial cable at ODU, splicing points of coaxial cable, and connection points of grounding cables.

NEC Corporation

PASOLINK Maintenance Quick Reference

3.3

Preventive Maintenance Flowchart


The preventive maintenance procedures are outlined here in a form of flowchart for quick reference.
START

Radio Equipment

Aerial Equipment

Int erface Cable & Connector

Visual inspect ion?

Visual inspect ion?

Visual inspect ion?

Check meter reading

Check loose connect ion

Check loose connect ion

ODU PS V Rust prevent ion

Check wat erproof

Tx Power

Rx Signal level

Go to Correct ive M aint enance Procedures

Check configurat ion

END

NEC Corporation

PASOLINK Maintenance Quick Reference

Corrective Maintenance
Corrective maintenance covers fault isolation, replacement and alignment. The fault isolation procedure describes isolating equipment-level faults. Therefore, if an ODU or IDU is faulty, it should be replaced with a spare and aligned. During corrective maintenance, carefully observe the precautions given in Section 2.1.2 of this document until alignment is completed.

4.1

Corrective Maintenance Procedures


Radio Equipment
1. Confirmation of alarm and / or malfunction a) Confirmation of alarms, which are identified through: Red alarm LED indication on the IDU or Notification from external equipment During alarm conditions, red alarm LEDs on the IDU are lit except when there is a power supply failure. Faults can be isolated using the LED indications. Table C-l provides information for isolating faults at a station.

4.1.1

Table C-l Fault Isolation by LED Indication on IDU


LED Indication IDU ODU Fault Location IDU ODU

b) Confirmation of malfunction using PNMS or PNMT. 2. Identify faulty equipment by observing PNMS and/or alarm indication on IDU, identify the station and equipment where alarm and/or malfunction occurred. 3. Prepare necessary test equipment and accessories, PC and connection cable and Spare Equipment for replacement. 4. Pinpoint the fault equipment as follows. a) Check individual alarm and status condition of ODU/IDU by using the PNMT. Refer to the PNMT user's manual for detailed procedure for monitoring. b) Pinpoint the origin of fault with help of the instruction manual of the equipment. c) If alarm and/or malfunction is due to equipment, go to next step. If not, go to next step 5. 5. Replacement of.

NEC Corporation

PASOLINK Maintenance Quick Reference

10

a) IDU. The Manufacturer does not recommend replacement of modules within IDU. If a fault is identified with the IDU, the complete unit should be replaced with a spare. The faulty unit is to be returned to the factory for repair. The following actions shall be performed on the new IDU before connection to ODU. i) ii)

*Note: The latest configuration file stored for the faulty IDU shall be used.

Downloading of the appropriate configuration file*.

Set the Equipment Configuration for the station according to the site inventory record. At least, TX/RX Frequency (CH) TX Attenuation, Bit Rate and Frame ID shall be set.

When replacing with a new unit, the start up procedure should be followed. Refer to the equipment instruction manual for details. b) ODU. Before replacing the ODU with a spare, the spare must be set to meet the required functions. Provided here are procedures for replacing the ODU with spares after fault isolation and/or presetting.

Removing
i) ii)

iii)

iv) v) vi)

Lessen four screws (M6) on the ODU. Remove the ODU from mounting bracket. Replace ODU with a spare, taking care when handling the waveguide contact surface.

Note: Be careful not to damage the O-ring between the waveguide and ODU.

Turn off the POWER switch on the front panel of the IDU. Loosen tightening rings of the IF IN/OUT (N) on the ODU by turning them counter-clockwise. For waveguide connector type of ODU, to remove the waveguide from the RF IN/OUT, remove the four waveguide fixing screws using a screwdriver.

Remounting
vii)

When H polarization is required, rotate the ODU so as to go up the plate marked with H. viii) When V polarization is required, rotate the ODU so as to go up the plate marked with V. ix) Confirm if the O-ring is to be placed in the original position properly. x) Put new ODU on the mounting bracket and align the bolts of the ODU with the bolt holes of the mounting bracket. xi) Tighten the four screws (M6) on the ODU using a suitable screwdriver. xii) Connect coaxial cable between the IF IN/OUT jacks on the IDU and ODU.

NEC Corporation

PASOLINK Maintenance Quick Reference

11

xiii) For waveguide connect type of ODU, connect waveguide to RF IN//OUT with four screws using a suitable screwdriver. xiv) Confirm that the ODU is firmly installed on the mounting bracket. xv) Confirm the cable routing and the cable has been fastened properly. xvi) Turn on the POWER switch on the front of the IDU. Note: Allow equipment to warn warm at least several minutes. 6. Alignment. After replacing ODU or IDU with spares, the ODU or IDU must be aligned as follows.

Note: After cable connection, the connector part shall be wrapped by self-bonding tape for waterproof.

a) Verify that connector is firmly connected. b) Turn on the power switch on the IDU. c) Connect tester (digital multi-meter) to LINE IN (-) and LINE IN (+) terminals above the power cable unit of the IDU. Confirm that the meter indication is described in Table C-2.

Caution: After replacing any unit with a spare, allow equipment to warm before at least several minutes before alignment.

Table C-2 Meter Reading


Check Item LINE V Allowable +/- 20.0 to +/-60.0 V DC (PASOLINK) +/- 36.0 to +/- 60 VDC (PASOLIN+)

d) Referring to para. B), confirm that the meter indication is normal.

ODU

e) Referring to the procedure for condition setting of ODU and IDU described in the equipment instruction manual, perform radio frequency and TX output power setting for the ODU.

Referring to the procedure for condition setting of ODU and IDU described in the equipment instruction manual, perform each item setting for the IDU. g) Connect the PNMT to the LA PORT of the IDU using an RS232C cable. (PASOLINK) g-2) Connect the PNMT to the PNMT port of IDU using an RS-232C cable (PASOLINK+) h) Confirm if the Equipment Configuration data stored in the equipment is appropriate. i) Record the Equipment Configuration data as a station inventory data.

IDU
f)

NEC Corporation

PASOLINK Maintenance Quick Reference

12

j)

The faulty ODU and/or IDU shall be returned to the Supplier for repair.

NEC Corporation

PASOLINK Maintenance Quick Reference

13

4.1.2

Aerial Equipment
1. Confirm malfunction. Make sure the observed malfunction is due aerial equipment. 2. Antenna Orientation. If malfunction is due to drift of antenna direction, re-orientation of antenna should be performed. a) At each station, remove the cap from the OW/RX LEV MON jack on ODU. b) Connect cables with F-type plug for Digital Multi-meter to RX LEV MON jack. c) Adjust azimuth and elevation angle for the antenna direction alternately so that the voltage measuring value becomes maximum. d) Disconnect digital multi-meter from the RX LEV MON jacks. e) Reconnect the cap removed in step a) above. Note In case of PASOLINK+, an Antenna Alignment Mode which extend the range of RX LEVEL MON is available. The detailed procedure shall be referred as per the instruction manual of PASOLINK+. 3. Tighten all bolts and nuts to the specified torque. (refer to installation instruction of antenna). 4. If any rust found, following action should be made. a) For antenna, clean first by removing oil and dirt completely with solvent and then washing with water. Then apply top coat with ally alkyd enamel diffusive paint (belcoat No.5500) or equivalent. b) For hot dip galvanized parts of the steel structure, first completely remove rust, dirt, etc., on the position causing exfoliation of plating. Then apply Amercoat No.160 with a brush or sprayer (Thickness: more than 70 microns) manufactured by Amercoat (AMERCOAT EUROPE). Note that more than 70 microns is roughly amount to one (1) or two (2) times of paint brushing, or two (2) or three (3) times of paint spraying. 5. Replacement. If any surface damage of abnormal appearance is observed on aerial equipment, it must be replaced with spare according to owner's decision.

NEC Corporation

PASOLINK Maintenance Quick Reference

14

4.1.3

Interface Cables and Connectors


1. Check if there is any malfunction along the interface cables. 2. If any surface damage or abnormal appearance is found on the following items, replace it with new one according to owner's decision. Items to be inspected are: a) The connectors of jumper cable between ODU and IDU b) Jumper cables c) Frame ground of ODU d) Grounding of feeder e) IF cable connector f) Power supply cable and connector g) Traffic IN/OUT cable and connectors h) Alarm cable and connectors i) Service channel cables and connector j) NMS cable and connector 3. If any loose connection found, tighten and make sure all connections are fixed firmly. 4. If any water ingress or deterioration of waterproof treatment is found, waterproof treatment by self-bonding tape shall be replaced with new one.

NEC Corporation

PASOLINK Maintenance Quick Reference

15

4.2

Corrective Maintenance Flowchart


The corrective maintenance procedures are outlined here in a form of flowchart for quick reference.
START

Radio Equipment

Aerial Equipment

Int erface Cable & Connector

Alarm observed by prvent ive maint enance

M alfuct ion observed

M alfunct ion observed

Ident ify the faulty equipment

Ant enna direction

Any damage

Prepare necessary spare part s, t est equipment and instruct ion

M ake ant enna orient at ion according to inst ruction m anual

Replace damaged part if necessary

Tight en bolts and nut s to the specific torque Any loose connect ion

P inpoint the faulty equipment with help of inst ruct ion manual

Any rust?

Due to equipment

Clean and apply touch up paint

Tight en the connectors

Any surface damange? Replace the fault part s with spare Replace damaged part if necessary Perform check to restore normal operat ion Ret urn faulty ODU / IDU for analysis

Any wat er ingress?

Replace wat erproof treatment

END

NEC Corporation

PASOLINK Maintenance Quick Reference

16

4.3

List of Alarms
A list of alarms generated by PASOLINK/PASOLINK+ system is described as follow. The reasons for the alarms and the action to take to correct the faults are also included. Note that these alarms appear in the Active Alarm window of the PNMS (PASOLINK Network Management System) software when faults occur. Numbers (1) through (20) in the Items to Check column are in reference to PASOLINK equipment in Figure 1 through 3 at the back of the list.

Table.1 List of check items for alarm item (for PASOLINK 1 + 0)


Alarm Items Alarm Description Items to Check Equipment where Alarm is from Possible Cause of Failure or Action to Take IDU DTE

INPUT -CH 01-16

Loss of input data stream from DTE <Note 1> a) Check DTE

b) Check data input cable and connector failure Data input cable and (short-circuit). (1) connector failure 2 AIS RCVD-CH 01-16 AIS (all "1") is received from DTE <Note 1> a) Check DTE b) Check data input cable and connector. (1) 3 AIS SEND-CH 01-16 AIS (all "1") is transmitted to DTE <Note 1> a) Check RX LEVEL at item 25, if on>> b) Check RX CLK LOSS 1-4 at item 14 c) Check FRAME ASYNC at item 17 d) Check DEM at item 22. If above item on and RX Level normal>> 4 BP OUTPUT-CH 01-16 Loss of output data stream to DTE <Note 1> a) Check data output cable and connector failure (short-circuit). (2) b) Check 2M INTFC of IDU (data type, speed, etc). 5 6 WS INPUT WS AIS RCVD Loss of Way Side traffic input <Note 2,3> Check wayside card. (3) AIS for Way Side is received <Note 2,3> a) Check wayside card. (3) IDU Data output cable and connector failure IDU IDU Wayside card failure IDU<Note6> Wayside card failure IDU<Note6> DTE Data input cable and connector failure IDU<Note6> Antenna system or natural fading; Replace IDU

NEC Corporation

PASOLINK Maintenance Quick Reference

17

b) Check wayside data input cable and connector. (4) c) Check DTE (data type, speed, etc) 7 WS AIS SEND AIS for Way Side is transmitted <Note 2,3> Check wayside card. (3) 8 WS BP OUTPUT Way Side output loss <Note 3> a) Check wayside data output cable and connector. (4) b) Check DTE 9 34M INPUT Loss of 34M input data stream from DTE <Note 1> a) Check data input cable and connector. (1) b) Check DTE (data type, speed, etc) 10 34M OUTPUT

Wayside data input cable and connector failure DTE IDU<Note6> Wayside card failure IDU Data output cable and connector failure DTE IDU Data input cable and connector failure DTE

Loss of 34M output data stream to DTE <Note 1> IDU a) Check data output cable and connector. (2) b) Check DTE (data type, speed, etc) Data output cable and connector failure DTE IDU Antenna system or natural fading Replace IDU

11 34M AIS SEND

AIS (all "1") is transmitted to DTE <Note 1> a) Check RX LEVEL at item 25, if on>> b) Check RX CLK LOSS 1-4 at item 13 c) Check FRAME ASYNC at item 17 d) Check DEM at item 22. If above item on,>>

12 34M AIS RCVD

AIS (all "1") is received from DTE <Note 1> a) Check DTE (data type, speed, etc)

IDU DTE

b) Check data input cable and connector failure. Data output cable (1) and connector failure 13 TX CLK LOSS 1-4 INTFC Transmitter Clock Loss <Note 1> a) Check 2M interface card. (5) 14 RX CLK LOSS 1-4 INTFC Receiver Clock Loss <Note 1> a) Check RX LEVEL at item 25, if on>> b) Check RX CLK LOSS 1-4 at item 13 c) Check FRAME ASYNC at item 17 IDU 2M interface card failure IDU Antenna system or natural fading Replace IDU

NEC Corporation

PASOLINK Maintenance Quick Reference

18

d) Check DEM at item 22. If above item on and RX level normal>> 15 MUX 1-4 Loss of TX DATA at INTFC <Note 1> a) Check data rate setting using LCT or PNMT/S. b) Check 2M interface card. (5) 16 TX DPU Loss of TX DATA at TX DPU a) Check data rate setting using LCT or PNMT/S. b) Check 2M interface card. (5) 17 FRAME ASYNC Frame Asynchronous at RX DPU a) Check RX LEVEL at item 25, if on>> b) Check Frame ID using LCT or PNMT/S 18 HIGH BER BER > 10E-3 a) Check RX LEVEL at item 25, if on>> b) Check opposite site equipment 19 LOW BER BER > 10E-6 a) Check RX LEVEL at item 25, if on>> b) Check opposite site equipment 20 BER Degradation of BER (10E-3/-4/-5/-6 selectable) <This alarm is used for triggering of AIS injection> a) Check RX LEVEL at item 25, if on>> b) Check opposite site equipment 21 MOD MOD 850MHz PLL APC loop is out of lock a) Check atmosphere temperature b) If continues MOD alarm on 22 DEM Carrier Asynchronous a) Check RX LEVEL at item 25, if on>> b) Check atmosphere temperature 23 PMC-ALM CONT LINK Antenna system or natural fading Opposite site IDU Improve air flow Replace IDU IDU Antenna system or natural fading Improve air flow IDU IDU data rate setting 2M interface card failure IDU IDU Data rate setting 2M interface card failure IDU Antenna system or natural fading IDU setting IDU Antenna system or natural fading Opposite site IDU Antenna system or natural fading Opposite site IDU

Communication failed between ALM control card IDU of IDU and PMC a) Check PM Card. (6) PM card failure

NEC Corporation

PASOLINK Maintenance Quick Reference

19

24 OPR ALM

CPU communication error between IDU and ODU a) Check IF cable and connector (17)

IDU IF cable and connector failure ODU

25 TX POWER

Occurred when transmitter output power is decreased <Activated when 3 to 5dB lower than preset value> a) Check atmosphere temperature b) If continuous alarm on

Improve ODU temperature Replace ODU ODU

26 RX LEVEL

Receiving level is decreased <Activated when less than -95dBm+/-5dB> a) Check RX LEVEL, if lower>> b) Check channel number of own site and opposite site

Antenna system or natural fading Correct channel number ODU Improve ODU temperature Replace ODU ODU Improve ODU temperature Replace ODU ODU IF cable and connector failure IF cable length

27 TX APC

1st local loop out of lock a) Check atmosphere temperature b) If continues alarm on

28 RX APC

nd local loop out of lock a) Check atmosphere temperature b) If continues alarm on

29 IF INPUT

Occurred when TX IF input level is decreased <Activated when less than approx. -63dBm> a) Check IF cable and connector. (7) b) Check IF cable length and loss. (7)

30 ES THRESHOLD (15min)

Number of one second periods with one or more PNMS errored blocks a) Check RX LEVEL at item 25, if lower>> b) Check fading margin c) Check interference Antenna system or natural fading Link design condition Other near radio station

PNMS 31 SES THRESHOLD (15min) Number of one second periods which contain 30% or more errored blocks during available time only

NEC Corporation

PASOLINK Maintenance Quick Reference

20

a) Check RX LEVEL at item 25, if lower>> b) Check fading margin c) Check interference 32 SES THRESHOLD (day) Number of one second periods which contain 30% or more errored blocks during a day a) Check RX LEVEL at item 25, if lower>> b) Check fading margin c) Check interference 33 UAS THRESHOLD (15min) Unavailable second a) Check RX LEVEL at item 25, if lower>> b) Check fading margin c) Check interference 34 UAS THRESHOLD (day) Unavailable second a) Check RX LEVEL at item 25, if lower>> b) Check fading margin c) Check interference 35 BBE THRESHOLD (15min) Number of errored blocks as part of SES a) Check RX LEVEL at item 25, if lower>> b) Check fading margin c) Check interference 36 BBE THRESHOLD (day) Number of errored blocks as part of SES a) Check RX LEVEL at item 25, if lower>> b) Check fading margin c) Check interference 37 INPUT-1to 6 (or NAME) Connection loss of AUX input interface Check PM Card. (6) 38 Loss of AUX relay output interface

Antenna system or natural fading Link design condition Other near radio station PNMS Antenna system or natural fading Link design condition Other near radio station PNMS Antenna system or natural fading Link design condition Other near radio station PNMS Antenna system or natural fading Link design condition Other near radio station PNMS Antenna system or natural fading Link design condition Other near radio station PNMS Antenna system or natural fading Link design condition Other near radio station PNMS PM card failure PNMS

NEC Corporation

PASOLINK Maintenance Quick Reference

21

OUTPUT-1 to 4 (or NAME) Check PM Card. (6) 39 PNMS LINK Connection failed between PMC and PNMS a) Check PM Card. (6) b) Check Link connection. (8) c) Check PNMS cables. (9)
<Note 1> Unused channel/interface is masked according to the bit rate.

PM card failure PNMS PM card failure Link failure PNMS cable failure

<Note 2> Way Side alarm inhibit function is applicable. Setting this function inhibits the issuance of alarm. <Note 3> This item is masked in case of no WS system. <Note 4> This item is masked except for 1 x 34 MB system. <Note 5> The summarization of alarm outputs is fully user programmable; the table only shows the factory settings. <Note 6> ALM LED does not light by the factory settings. It is changeable to light by the settings

Table 2 List of check items against alarm item (for PASOLINK 1 + 1)


Alarm Items Alarm Description Items to Check 1 INPUT -CH01-16 Loss of input data stream from DTE <Note 1> a) Check DTE b) Check data input cable and connector failure (short-circuit) (1) 2 AIS RCVD-CH01-16 AIS (all "1") is received from DTE <Note 1> a) Check DTE (data type, speed, etc) b) Check data input cable and connector. (11) 3 AIS SEND-CH01-16 AIS (all "1") is transmitted to DTE <Note 1> a) Check RX LEVEL at item 48,49, if on>> Check RX CLK LOSS 1-4 at item 22 b) Check FRAME ASYNC at item 31, 32 Equipment where Alarm is from Possible Cause of Failure or Action to Take IDU TX No.1/No.2 IDU Data input cable and connector failure IDU <Note6> DTE Data output cable and connector failure IDU <Note6> RX No.1/No.2 <Note6> TX No.1/No.2 <Note6>

Antenna system or natural fading Replace IDU

NEC Corporation

PASOLINK Maintenance Quick Reference

22

c) Check DEM at item 41, 42. If above item on and RX Level normal>> 4 BP OUTPUT-CH01-16 Loss of output data stream to DTE <Note 1> a) Check data output cable and connector failure(short-circuit)(12) b) Check 2M INTFC setting of IDU (data type, speed, etc) 5 WS INPUT Loss of Way Side traffic input <Note 2,3> Check wayside card. (13) 6 WS AIS RCVD AIS for Way Side is received <Note 2,3> a) Check wayside card. (13) b) Check wayside data input cable and connector. (14) c) Check DTE (data type, speed, etc) 7 WS AIS SEND AIS for Way Side is transmitted <Note 2,3> Check wayside card. (13) 8 WS BP OUTPUT Way Side output loss <Note 3> a) Check wayside data output cable and connector. (14) b) Check DTE 9 34M INPUT (No.1) Loss of input data stream from DTE <1x34MB>, <Note7> a) Check data input cable and connector. (11) b) Check DTE (data type, speed, etc) Loss of input data stream from DTE <1x34MB>, <Note7> a) Check data input cable and connector. (11) b) Check DTE (data type, speed, etc) AIS is received from DTE <1x34MB>, <Note7> a) Check DTE (data type, speed, etc) IDU RX No.1/No.2

Data output cable and connector failure IDU IDU TX No.1/No.2

Wayside card failure IDU <Note6> TX No.1/No.2 <Note6>

Wayside card failure Data output cable and connector failure DTE IDU <Note6> RX No.1/No.2 <Note6>

Wayside card failure IDU RX No.1/No.2

Data output cable and connector failure DTE IDU TX No.1

Data output cable and connector failure DTE IDU TX No.2

10

34M INPUT (No.2)

Data output cable and connector failure DTE IDU <Note6> DTE TX No.1<Note6>

11

34M AIS RCVD (No.1)

NEC Corporation

PASOLINK Maintenance Quick Reference

23

12

34M AIS RCVD (No.2)

b) Check data input cable and connector. (11) AIS is received from DTE <1x34MB>, <Note7> a) Check DTE (data type, speed, etc) b) Check data input cable and connector. (11) AIS is transmitted to DTE <1x34MB>, <Note7> a) Check RX LEVEL at item 48,49, if lower>> b) Check RX CLK LOSS 1-4 at item 22 c) Check FRAME ASYNC at item 31, 32 d) Check DEM at item 41, 42. If above item on and RX Level normal>> AIS is transmitted to DTE <1x34MB>, <Note7> a) Check RX LEVEL at item 48,49, if on>> b) Check RX CLK LOSS 1-4 at item 22 c) Check FRAME ASYNC at item 31, 32 d) Check DEM at item 41, 42. If above item on and RX Level normal>> Loss of output data stream to DTE <1x34MB>, <Note7> a) Check data output cable and connector. (12) b) Check DTE (data type, speed, etc) Loss of output data stream to DTE <1x34MB>, <Note7> a) Check data output cable and connector. (12) b) Check DTE (data type, speed, etc) Loss of TX DPU clock to 2M(8M) INTFC

Data output cable and connector failure IDU <Note6> DTE Data output cable and connector failure IDU <Note6> RX No.1/No.2 <Note6> TX No.2<Note6>

13

34M AIS SEND (No.1)

Antenna system or natural fading Replace IDU

14

34M AIS SEND (No.2)

IDU <Note6>

RX No.1/No.2 <Note6>

Antenna system or natural fading Replace IDU

15

34M BP OUTPUT (No.1)

IDU

RX No.1

Data output cable and connector failure DTE IDU RX No.2

16

34M BP OUTPUT (No.2)

Data output cable and connector failure DTE IDU TX No.1

17

TX DPU (No.1)

NEC Corporation

PASOLINK Maintenance Quick Reference

24

a) Check data rate setting using LCT or PNMT/S b) Check 2M interface card. (15) 18 TX DPU (No.2) Loss of TX DPU clock to 2M(8M) INTFC a) Check data rate setting using LCT or PNMT/S 19 RX DPU (No.1) b) Check 2M interface card. (15) Loss of RX DPU clock to 2M(8M) INTFC a) Check data rate setting using LCT or PNMT/S b) Check 2M interface card. (15) Loss of RX DPU clock to 2M(8M) INTFC a) Check data rate setting using LCT or PNMT/S 21 TX CLK LOSS 1-4 b) Check 2M interface card. (15) INTFC Transmitter clock loss <Note 1> a) Check data rate setting using LCT or PNMT/S 22 RX CLK LOSS 1-4 b) Check 2M interface card. (15) INTFC Receiver clock loss <Note 1> a) Check RX LEVEL at item 48,49, if lower>> b) Check RX CLK LOSS 1-4 at item 22.

IDU data rate setting 2M interface card failure IDU TX No.2

IDU data rate setting 2M interface card failure IDU RX No.1

IDU data rate setting 2M interface card failure IDU RX No.2

20

RX DPU (No.2)

IDU data rate setting 2M interface card failure IDU TX No.1/No.2

IDU data rate setting 2M interface card failure IDU RX No.1/No.2

Antenna system or natural fading; Replace IDU

c) Check FRAME ASYNC at item 31, 32. d) Check DEM at item 41, 42. If above item on and RX Level normal>> 34M INTFC Transmitter clock loss <Note 4>, <Note7> a) Check data rate setting using LCT or PNMT/S b) Check connector between MD and SW (behind MD unit). (18) 34M INTFC Transmitter clock loss <Note 4>, <Note7> a) Check data rate setting using LCT or PNMT/S

23

TX CLK LOSS (No.1)

IDU

TX No.1

IDU data rate setting Connector failure between MD and SW IDU TX No.2 IDU data rate setting

24

TX CLK LOSS (No.2)

NEC Corporation

PASOLINK Maintenance Quick Reference

25

25

RX CLK LOSS (No.1)

b) Check connector between MD and SW (behind MD unit). (18) 34M INTFC Receiver clock loss <Note 4>, < Note7> a) Check data rate setting using LCT or PNMT/S b) Check connector between MD and SW (behind MD unit). (18) 34M INTFC Receiver clock loss <Note 4>, <Note7> a) Check data rate setting using LCT or PNMT/S b) Check connector between MD and SW (behind MD unit). (18) Loss of TX DATA from INTFC at TX DPU <Note 1> a) Check data rate setting using LCT or PNMT/S b) Check 2M interface card. (15)

Connector failure between MD and SW IDU RX No.1 IDU data rate setting Connector failure between MD and SW IDU RX No.2 IDU data rate setting Connector failure between MD and SW IDU TX No.1 IDU data rate setting 2M interface card failure IDU TX No.2

26

RX CLK LOSS (No.2)

27

MUX 1-4(No.1)

28

MUX 1-4 (No.2)

Loss of TX DATA from INTFC at TX DPU <Note 1> a) Check data rate setting using LCT or PNMT/S

IDU data rate setting 2M interface card failure IDU TX No.1

29

TX DPU (No.1)

b) Check 2M interface card. (15) Loss of TX DATA to MOD at TX DPU a) Check data rate setting using LCT or PNMT/S.

IDU data rate setting 2M interface card failure IDU TX No.2

30

TX DPU (No 2)

b) Check 2M interface card. (15) Loss of TX DATA to MOD at TX DPU a) Check data rate setting using LCT or PNMT/S b) Check 2M interface card. (15)

IDU data rate setting 2M interface card failure IDU RX No.1 Antenna system or natural fading IDU setting IDU RX No.2 Antenna system or natural fading IDU setting IDU RX No.1

31

FRAME ASYNC (No.1)

Frame Asynchronous at RX DPU a) Check RX LEVEL at item 48,49 if lower>> b) Check Frame ID using LCT or PNMT/S

32

FRAME ASYNC (No.2)

Frame Asynchronous at RX DPU a) Check RX LEVEL at item 48,49 if lower>> b) Check Frame ID using LCT or PNMT/S

33

HIGH BER (No.1)

BER > 10E-3

NEC Corporation

PASOLINK Maintenance Quick Reference

26

a) Check RX LEVEL at item 48,49 if lower>> b) Check opposite site equipment 34 HIGH BER (No.2) BER > 10E-3 a) Check RX LEVEL at item 48,49 if lower>> b) Check opposite site equipment BER > 10E-6 a) Check RX LEVEL at item 48,49 if lower>> 36 LOW BER (No.2) b) Check opposite site equipment BER > 10E-6 a) Check RX LEVEL at item 48,49 if lower>> 37 BER (No.1) b) Check opposite site equipment Degradation of BER (10E-3/-4/-5/-6 selectable) <This alarm is used for triggering of AIS injection> a) Check RX LEVEL at item 48,49 if lower>> 38 BER (No.2) b) Check opposite site equipment Degradation of BER (10E-3/-4/-5/-6 selectable) <This alarm is used for triggering of AIS injection> a) Check RX LEVEL at item 48,49 if on>> 39 MOD (No.1) b) Check opposite site equipment MOD 850MHz PLL APC loop is out of lock a) Check atmosphere temperature 40 MOD (No.2) b) If continues MOD alarm on MOD 850MHz PLL APC loop is out of lock a) Check atmosphere temperature 41 DEM (No.1) b) If continues MOD alarm on Carrier asynchronous a) Check RX LEVEL at item 48,49 if on>> 42 DEM (No.2) b) Check atmosphere temperature Carrier asynchronous a) Check RX LEVEL at item 48,49 if on>>

Antenna system or natural fading Opposite site IDU RX No.2 Antenna system or natural fading Opposite site IDU RX No.1 Antenna system or natural fading Opposite site IDU RX No.2 Antenna system or natural fading Opposite site IDU RX No.1

35

LOW BER (No.1)

Antenna system or natural fading Opposite site IDU RX No.2

Antenna system or natural fading Opposite site IDU TX No.1

Improve air flow Replace MD (No.1) IDU TX No.2

Improve air flow Replace MD (No.2) IDU RX No.1 Antenna system or natural fading Improve air flow IDU RX No.2 Antenna system or natural fading

NEC Corporation

PASOLINK Maintenance Quick Reference

27

b) Check atmosphere temperature 43 PMC-ALM CONT LINK Communication fail between ALM control card of IDU and PMC a) Check PM Card. (16) CPU communication error between IDU and ODU a) Check IF cable and connector. (17) CPU communication error between IDU and ODU a) Check IF cable and connector. (17) Transmitter output power decrease <Activated when 3 to 5dB lower than preset.> a) Check atmosphere temperature b) If continues alarm on Transmitter output power decrease <Activated when 3 to 5dB lower than preset.> a) Check atmosphere temperature b) If continues alarm on 48 RX LEVEL (No.1) Receiving level decrease <Activated when less than -95dBm+/5dB) a) Check RX LEVEL, if lower>> b) Check channel number of own site and opposite site Receiving level decrease <Activated when less than -95dBm+/5dB) a) Check RX LEVEL, if lower>> b) Check channel number of own site and opposite site RF 1st local APC loop out of lock a) Check atmosphere temperature b) If continues alarm on RF 1st local APC loop out of lock a) Check atmosphere temperature b) If continues alarm on RF 2nd local APC loop out of lock a) Check atmosphere temperature

Improve air flow IDU SW

PM card failure IDU TX/RX No.1

44

OPR ALM (No.1)

IF cable and connector failure IDU TX/RX No.2

45

OPR ALM (No.2)

IF cable and connector failure ODU TX No.1

46

TX POWER (No.1)

Improve ODU temperature Replace ODU ODU TX No.2

47

TX POWER (No.2)

Improve ODU temperature Replace ODU ODU RX No.1

Antenna system or natural fading Correct channel number ODU RX No.2

49

RX LEVEL (No.2)

Antenna system or natural fading Correct channel number ODU TX No.1 Improve ODU temperature Replace ODU ODU TX No.2 Improve ODU temperature Replace ODU ODU RX No.1 Improve ODU temperature

50

TX APC (No.1)

51

TX APC (No.2)

52

RX APC (No.1)

NEC Corporation

PASOLINK Maintenance Quick Reference

28

53

RX APC (No.2)

b) If continues alarm on RF 2nd local APC loop out of lock a) Check atmosphere temperature b) If continues alarm on TX IF input level decrease <Activated when less than approx. 63dBm> a) Check IF cable and connector. (17) b) Check IF cable length and loss. (17)

54

IF INPUT (No.1)

Replace ODU ODU RX No.2 Improve ODU temperature Replace ODU ODU TX No.1 IF cable and connector failure IF cable length ODU TX No.2

55

IF INPUT (No.2)

TX IF input level decrease <Activated when less than approx. 63dBm> a) Check IF cable and connector. (17) b) Check IF cable length and loss. (17) CPU communication error between MD and SW

IF cable and connector failure IF cable length SW/MDP TX/RX No.1

56

MDP CPU (No.1)

Check connector behind MD. (18) 57 MDP CPU (No.2) CPU communication error between MD and SW Check connector behind MD. (18) Number of one second periods with one or more errored blocks a) Check RX LEVEL at item 48,49, if lower>> b) Check fading margin c) Check interference 59 SES THRESHOLD (15min) Number of one second periods which contain 30% or more errored blocks during available time only a) Check RX LEVEL at item 48,49, if lower>> b) Check fading margin c) Check interference 60 SES THRESHOLD (day) Number of one second periods which contain 30% or more errored blocks during a day a) Check RX LEVEL at item 48,49, if lower>> b) Check fading margin

Connector failure behind MD Unit SW/MDP TX/RX No.2 Connector failure behind MD Unit Common PNMS Antenna system or natural fading Link design condition Other near radio station PNMS Common

58

ES THRESHOLD (15min)

Antenna system or natural fading Link design condition Other near radio station PNMS Common

Antenna system or natural fading Link design condition

NEC Corporation

PASOLINK Maintenance Quick Reference

29

c) Check interference 61 UAS THRESHOLD (15min) Unavailable second a) Check RX LEVEL at item 48,49, if lower>> b) Check fading margin c) Check interference 62 UAS THRESHOLD (day) Unavailable second a) Check RX LEVEL at item 48,49, if lower>> b) Check fading margin c) Check interference 63 BBE THRESHOLD (15min) Number of errored blocks as part of SES a) Check RX LEVEL at item 48,49, if lower>> b) Check fading margin c) Check interference 64 BBE THRESHOLD (day) Number of errored blocks as part of SES a) Check RX LEVEL at item 48,49, if lower>> b) Check fading margin c) Check interference 65 INPUT-1-6 (or NAME) Connection loss of AUX input interface Check PM Card. (16) 66 OUTPUT-1-4 (or NAME) Loss of AUX relay output interface Check PM Card. (16) 67 PNMS LINK Connection fail between PMC and PNMS 1. Check PM Card. (16) 2. Check Link connection (20) 3. Check PNMS cables. (19)
<Note 1> Unused channel/interface is masked according to the bit rate.

Other near radio station PNMS Common

Antenna system or natural fading Link design condition Other near radio station PNMS Common

Antenna system or natural fading Link design condition Other near radio station PNMS Common

Antenna system or natural fading Link design condition Other near radio station PNMS Common

Antenna system or natural fading Link design condition Other near radio station AUX SW UNIT

AUX

SW UNIT

PM card failure PNMS Common

PM card failure Link failure PNMS cable failure

<Note 2> Way Side alarm inhibit function is applicable. Setting this function inhibits the issuance of alarm. <Note 3> This item is masked in case of no WS system.

NEC Corporation

PASOLINK Maintenance Quick Reference

30

<Note 4> This item is masked in case of 1x34MB system. <Note 5> The summarization of alarm outputs is fully user programmable; the table only shows the factory settings. <Note 6> ALM LED does not light by the factory settings. It is changeable to light by the settings

NEC Corporation

PASOLINK Maintenance Quick Reference

31

Table.3 List of check items for alarm item (for PASOLINK+ 1 + 0)


Alarm Items Alarm Description Items to Check Equipment where Alarm is from Possible Cause of Failure or Action to Take IDU

MAIN INTFC LOS (MUX) Input STM-1 signal is lost (From MUX)

a) Check data input cable and connector failure Data input cable and from MUX (Short-circuit) connector failure b) Check MUX 2 MAIN INTFC LOF (MUX) Frame synchronization of input STM-1 signal (From MUX) is lost MUX IDU

a) Check data input cable and connector failure Data input cable and from MUX (Short-circuit) connector failure b) Check MUX 3 E-BER (MUX) BER is worse than preset value (10-3 to 10-5, selectable) IDU

a) Check data input cable and connector failure Data input cable and from MUX (Short circuit/Loose connect) connector failure b) Check MUX 4 SD (MUX) BER is worse than preset value (10 to 10 , selectable) a) b) 5
-5 -9

MUX IDU

Check data input cable and connector failure Data input cable and from MUX (Short circuit/Loose connect) connector failure Check MUX MUX IDU IDU/INTFC failure (IDU replace) IDU IDU/INTFC failure (IDU replace)

MAIN INTFC LOS (DMR) Input STM-1 signal is lost (From Radio) a) Check IDU and INTFC card

MAIN INTFC LOF (DMR) Frame synchronization of input STM-1 signal (From Radio) is lost a) Check IDU and INTFC card

E-BER (DMR)

BER is worse than preset value (10-3 to 10-5, selectable) a) b) Check RX LEVEL, if lower>> Check opposite Station

IDU Antenna system or natural fading Opposite station

NEC Corporation

PASOLINK Maintenance Quick Reference

32

c) 8 SD (DMR)

Check IDU and INTFC card

IDU/INTFC (Replace IDU) IDU Antenna system or natural fading Opposite station

BER is worse than preset value (10-5 to 10-9, selectable) a) Check RX LEVEL, if lower>> b) Check opposite Station

MAIN INTFC

150M INTFC/OPT INTFC/10/100BASE-T INTFC 150M Intfc/Opt Intfc module failure /10/100BASE-T Intfc a) Check IDU/INTFC card IDU/INTFC (Replace IDU) IDU

10 LINK

Link of LAN (10/100 BASE-T INTFC) and associated equipment is not established a) b) c)

Check data input cable and connector failure Data input cable and from/to DTE connector failure Check DTE Check LAN card inside IDU DTE LAN INTFC (Replace IDU)

11 SUB INTFC

WS INTFC,WS/ALM INTFC, ALM INTFC or LAN IDU CARD(DSC) module failure a) Check each Sub Module Sub INTFC (Replace IDU) IDU IDU (Replace IDU) IDU Improve enveronment condition of IDU Replace IDU IDU Antenna system or natural fading Improve enveronment condition of IDU IDU Setting IDU Replace IDU IDU DC Voltage unstable

12 MD CPU ALM

Communication between modules failure a) Check IDU

13 MOD ALM

Modulator failure a) Check Atmosphere Temperature

b) 14 DEM ALM

If continues MOD alarm on,

Demodulator failure and input IF signal is lost a) b) Check RX LEVEL, if lower>> Check Atmosphere Temperature

c) 15 MODEM

Check Frame ID using LCT or PNMT/S

MODEM failure a) Check IDU

16 PS

DC-DC CONV failure a) Check DC Line voltage provided to IDU

NEC Corporation

PASOLINK Maintenance Quick Reference

33

b) c) 19 TX PWR ALM

Check Power cable and connector If continuous PS ALM on

Power CBL Connector Replace IDU

Transmit RF power increases/decreases approx ODU 3dB from normal a) Check Atmosphere Temperature Improve enveronment condition of ODU Replace ODU IDU IF cable and connector failure IF cable loss ODU

b) 20 TX INPUT ALM

If continues TX PWR ALM alarm on,

TX IF input signal from the IDU is lost a) b) Check IF Cable and Connector Check IF Cable Loss

21 RX LEVEL ALM

Receiver input level decreases below squelch level as shown below 32QAM : -81dBm 128QAM : -72dBm a) b) Check RX LEVEL, if lower>> Check opposite site

Antenna system or natural fading Opposite site ODU Improve ODU temperature Replace ODU ODU IF cable and connector failure MAINT

22 APC ALM

Local oscillator is unlocked a) b) Check Atmosphere Temperature If continues alarm on

23 CABLE ALM

Communication between the ODU and IDU is lost a) Check IF cable and connector

24 MAINT

The equipment is in maintenance mode. In this mode, the following control can be performed. ATPC manual control Loopback TX mute ALS manual restart CW

NEC Corporation

PASOLINK Maintenance Quick Reference

34

Table.4 List of check items for alarm item (for PASOLINK+ 1 + 1)


Alarm Items Alarm Description Items to Check Equipment where Alarm is from Possible Cause of Failure or Action to Take IDU IDU No 1/2

MAIN INTFC LOS (MUX) Input STM-1 signal is lost (From MUX) a) b)

Check data input cable and connector failure Data input cable and from MUX (Short-circuit) connector failure Check MUX MUX IDU IDU No 1/2

MAIN INTFC LOF (MUX) Frame synchronization of input STM-1 signal (From MUX) is lost a) b)

Check data input cable and connector failure Data input cable and from MUX (Short-circuit) connector failure Check MUX IDU IDU No 1 /2

E-BER (MUX)

BER is worse than preset value (10-3 to 10-5, selectable)

a) Check data input cable and connector failure Data input cable and from MUX (Short circuit/Loose connect) connector failure b) Check MUX 4 SD (MUX) BER is worse than preset value (10 to 10 , selectable)
-5 -9

MUX IDU IDU No 1 /2

a) Check data input cable and connector failure Data input cable and from MUX (Short circuit/Loose connect) connector failure b) Check MUX 5 MAIN INTFC LOS (DMR) Input STM-1 signal is lost (From Radio) a) Check IDU and INTFC card 6 MAIN INTFC LOF (DMR) Frame synchronization of input STM-1 signal (From Radio) is lost a) Check IDU and INTFC card 7 E-BER (DMR) BER is worse than preset value (10 to 10 , selectable) a) Check RX LEVEL, if lower>> b) Check opposite Station c) Check IDU and INTFC card
-3 -5

MUX IDU IDU No 1 /2

IDU/INTFC failure IDU IDU No 1 /2

IDU/INTFC (IDU replace) IDU IDU No 1 /2

Antenna system or natural fading Opposite station IDU/INTFC (Replace IDU)

NEC Corporation

PASOLINK Maintenance Quick Reference

35

SD (DMR)

BER is worse than preset value (10 to 10 , selectable) a) b) Check RX LEVEL, if lower>> Check opposite Station

-5

-9

IDU

IDU No 1 /2

Antenna system or natural fading Opposite station

MAIN INTFC

150M INTFC/OPT INTFC/10/100BASE-T INTFC 150M Intfc/Opt Intfc module failure /10/100BASE-T Intfc a) Check IDU/INTFC card IDU/INTFC (Replace IDU) Link 1/ 2

10 LINK

Link of LAN (10/100 BASE-T INTFC) and associated equipment is not established a) b) c)

Check data input cable and connector failure Data input cable and from/to DTE connector failure Check DTE Check LAN card inside IDU DTE LAN INTFC (Replace IDU)

11 SUB INTFC

WS INTFC,WS/ALM INTFC, ALM INTFC or LAN WS, WS/ALM, ALM CARD(DSC) module failure INTFC or LAN Card a) Check each Sub Module Sub INTFC (Replace Sub Intfc) IDU IDU No 1/ 2

12 MD CPU ALM

Communication between modules failure a) Check IDU

IDU(Replace IDU) IDU IDU No 1 /2

13 MOD ALM

Modulator failure a) Check Atmosphere Temperature

Improve enveronment condition of IDU IDU(Replace IDU) IDU IDU No 1 /2

b) 14 DEM ALM

If continues MOD alarm on,

Demodulator failure and input IF signal is lost a) b) c) Check RX LEVEL, if lower>> Check Frame ID using LCT or PNMT/S Check Atmosphere Temperature

Antenna system or natural fading IDU Setting Improve enveronment condition of IDU IDU(Replace IDU)
-4 -6

d) 15 High BER ALM

If continues MOD alarm on,

BER is worse than preset value (10 to 10 , selectable) a) b) Check RX LEVEL, if lower>> Check opposite Station

IDU

IDU No 1/2

Antenna system or natural fading Opposite station

NEC Corporation

PASOLINK Maintenance Quick Reference

36

c) 16 Low BER ALM

Check IDU

IDU(Replace IDU) IDU Antenna system or natural fading Opposite station

BER is worse than preset value (10-6 to 10-12, selectable) a) b) c) Check RX LEVEL, if lower>> Check opposite Station Check IDU

17 MODEM

MODEM failure b) Check IDU

IDU

IDU No 1 /2

Replace IDU IDU IDU No 1 /2

18 PS

DC-DC CONV failure d) e) f) Check DC Line voltage provided to IDU Check Power cable and connector If continuous PS ALM on

DC Voltage unstable Power CBL Connector Replace IDU

19 TX PWR ALM

Transmit RF power increases/decreases approx ODU ODU No 1/2 3dB from normal c) Check Atmosphere Temperature Improve enveronment condition of ODU Replace ODU ODU ODU No 1/2 IF cable and connector failure IF cable loss ODU ODU No 1 /2

d) 20 TX INPUT ALM

If continues TX PWR ALM alarm on,

TX IF input signal from the IDU is lost c) d) Check IF Cable and Connector Check IF Cable Loss

21 RX LEVEL ALM

Receiver input level decreases below squelch level as shown below 32QAM : -81dBm 128QAM : -72dBm c) d) Check RX LEVEL, if lower>> Check opposite site

Antenna system or natural fading Opposite site ODU ODU No 1/2 Improve ODU temperature Replace ODU IF CBL Cable No 1 /2

22 APC ALM

Local oscillator is unlocked c) d) Check Atmosphere Temperature If continues alarm on

23 CABLE ALM

Communication between the ODU and IDU is lost b) Check IF cable and connector

IF cable and connector failure

NEC Corporation

PASOLINK Maintenance Quick Reference

37

24 MAINT

The equipment is in maintenance mode. In this mode, the following control can be performed. ATPC manual control Loopback TX mute ALS manual restart CW

MAINT

NEC Corporation

PASOLINK Maintenance Quick Reference

38

Appendix A Preventive Maintenance Checklist Preventive Maintenance Cheek List


Equipment Location Radio ODU IDU IDU through PNMT Site Name:_________________ Check Date Check Item / / / / / / / / Visual Visual ODU primary power supply Transmitter Power Receiving Level Configuration Setting Visual Tightened with specified torque? Rust Visual Tightened with specified torque? Rust Firmly fixed?

Aerial

Antenna

Bracket

Cable

Connectors of jumper between ODU and feeder Waterproof The jumper cable Firmly tied with antenna pole? Frame ground of ODU Firmly connected to the earth bar? The feeder Firmly connected to the earth bar? Firmly connected to the jumper cable? Water proof IF cable connector Firmly fixed? Traffic cable Firmly fixed? connector Alarm cable connector Firmly fixed? Service Channel Cable Firmly fixed? Frame ground of IDU Firmly connected to the earth bar? Power supply cable Firmly connected? and connector

NEC Corporation

PASOLINK Maintenance Quick Reference

39

Appendix B Site Inventory Data Record Sheet Site Inventory Data Record Sheet
Site Name:_________________ Installation Date:_________________ To: ODU1
Serial No.: Tx Frequency: MHz Channel No.: Transmitter Power: dBm Channel No.: Receiving Level: dBm Rx Frequency: MHz Channel No.: Transmitter Power: dBm Primary DC voltage: V Channel No.: Receiving Level: dBm MHz Rx Frequency: MHz

ODU2

Serial No.:

Tx Frequency:

IDU

Serial No.:

Bit rate: 2 2 MB 2 4 MB 2 8 MB 2 61 MB 8 1 MB

Frame ID Default

To: ODU1

Serial No.:

Tx Frequency: MHz Channel No.: Transmitter Power: dBm

Rx Frequency: MHz Channel No.: Receiving Level: dBm Rx Frequency: MHz MHz Channel No.: Receiving Level: dBm dBm V

ODU2

Serial No.:

Tx Frequency: Channel No.: Transmitter Power: Primary DC voltage:

IDU

Serial No.:

Bit rate: 2 2 MB 2 4 MB 2 8 MB 2 61 MB 8 1 MB

Frame ID Default

NEC Corporation