Clamp- On TRMS Power Meter with 3f Adapter

TRUE Power : (PF>0.5 or f<600) Range Resolution Accuracy (%rdg+dgts) Overload Protection 60.00KW (<100A) 0.01KW (5% + 20) 600VAC/ 600.0KW (>100A) 0.1KW (50, 60Hz) 1000AAC HP (1HP=745.7W) : (PF>0.5 or f<600) Range Resolution Accuracy (%rdg+dgts) Overload Protection 80.00HP (<100A) 0.01HP (5% + 20) 600VAC/ 800.0HP (>100A) 0.1HP (50, 60Hz) 1000AAC Apparent Power Range Resolution Accuracy (%rdg+dgts) Overload Protection 60.00KVA (<100A) 0.01KVA 600VAC/ (2.5% + 20) 600.0KVA (>100A) 0.1KVA 1000AAC PF & Phase Angle (50Hz, 60Hz) Range Resolution Accuracy -600/00/+600 0.10 3.00 -0.5/1/+0.5 Frequency Range Resolution 40Hz/1KHz 0.1Hz Accuracy (%rdg+dgts) (0.5% + 2) Sensitivity ACV>100V, ACA>10A

Bus-Bar upto 16mm x 65mm Cable upto 43mm Diameter

Sensitivity ACV>1.2V, ACA>6A Overload Protection 1000A

AC Current (50Hz to 400Hz) : TRMS Range 99.99A 999.9A Resolution 0.01A 0.1A Accuracy (%rdg+dgts) (2% + 20) (50,60Hz) (4% + 20) (40-400Hz) Sensitivity 0.10A 1.0A

mA TRMS : (AC + DC) (Burden Voltage : 5mV/mA) (50Hz to 400Hz) Range 99.99mA 999.9mA Resolution 0.01mA 0.1mA Accuracy (%rdg+dgts) (1% + 20) Sensitivity 0.20mA 2.0mA Overload Protection 600V

AC Voltage (50Hz to 400Hz) : TRMS Range 999.9mV Resolution 0.1mV Accuracy (%rdg+dgts) (1% + 20) (50,60Hz) (2% + 20) (40-100Hz) (1% + 20) (50,60Hz) (2% + 20) (40-400Hz) Sensitivity 2.0mV 0.020V 0.20V 2V 600V Overload Protection

3510PHW

9.999V 0.001V 99.99V 0.01V 600.0V 0.1V Input Impedance : 3MV DC Voltage Range Resolution

Accuracy (%rdg+dgts)

Sensitivity 2.0mV 0.020V 0.20V 2V

Features l 4 Digit LCD, 9999 Count, Autoranging l Data Hold, Auto Power Off l Dual Display KW + PF, KVA + f, KW + HP, KW + KVAR, V + A, A + Hz, V + Hz l Cable of Diameter upto 43mm / Busbar upto 65mm x 16mm l 3 Phase Adapter Applications l Check Current drawn in Motors and Compressors l Use MAX/MIN/REC in Temperature Mode to Assess Efficiency l Test Run/Start Capacitors l Analyze Temperature Data with the Aid of the Time Stamp l Resistance upto 100MV l Check for Energized Circuits l Capture Motor In-Rush Current Readings l Determine Peak Power Demand Periods l Ideal for Electrical Audit of Heating, Ventilation & Aircon Systems


Overload Protection 600V

999.9mV 0.1mV 9.999V 0.001V 99.99V 0.01V 600.0V 0.1V Input Impedance : 3MV

(1% + 20)

Resistance (Continuity < 40V on the 999.9V range) Range Resolution Accuracy (%rdg+dgts) Overload Protection 999.9V 0.1V 9.999KV 0.001KV (1% + 10) 600V 99.99KV 0.01KV 999.9KV 0.1KV MV Range 9.999MV 99.99MV Resolution 0.001MV 0.01MV Accuracy (%rdg+dgts) (5% + 10) Overload Protection 600V

Clamp- On TRMS Power Meter with 3f Adapter


General Specifications Numerical Dual Display Low Battery Indication Power Source Battery Life Sampling Rate Operating Temperature and Humidity Storage Temperature and Humidity Dimensions Weight Jaw Opening
0 0 0 0

m m m m

m m m m

0 0

0 0

Accessories

Usage
f
R N Load R Y B

: 4 Digit 9999 Count LCD : is displayed : 9V Battery x 1 : 32 hours approx. : 2.5 times/sec. (on KW, KVA, HP) : 0 C to 50 C (32 F to 122 F) RH < 80% : -10 C to 60 C (14 F to 140 F) RH < 70% : 247 x 76 x 39mm : 465gms Including Battery (approx.) : Cable Dia 43mm (max.) Bus Bar 16mm x 65mm : Carrying Case, Battery (installed), One Pair of Alligator Clip Test Lead, 3 Phase Adapter & Instruction Manual