Professional Documents
Culture Documents
August 2008
underground
The Marley Plumbing & Drainage range of underground drainage systems consists of two types of PVCu pipe for different applications. The solid wall range, predominately for private drainage and the Quantum structured wall range for sewer and highway drainage applications.
Contents
P. 4 P. 8 P. 1 0 P. 1 2 P. 1 6 P. 1 8 P. 2 0 P. 2 2 P. 2 6 P. 2 7
2
The systems Key components Design Installation data: Pipe laying Installation data: Shallow inspection chambers Installation data: Inspection chambers Installation data: Gully combinations Installation data: Making the connection British & European Standards Product information
3
underground
The systems
82mm, 110mm & 160mm diameters. Private drainage. Plain ended and socketted pipe. Adaptors to other materials.
Access fittings. 250mm and 450mm inspection chambers. Adjustable and variable bends. A wide range of gullies.
Pipe UP406
Pipe UP406 Slip coupling UE405 45 short radius bend UB455R Inspection chamber UCC7 Straight channel UCC4
Coupling UE407
A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695
4 5
underground
The systems
Quantum Sewer
Available in 150mm, 225mm & 300mm diameters. Suitable for: Adoptable foul and surface water sewers Private foul and surface water applications
Quantum Highway
Available in 150mm, 225mm, 300mm, 400mm, 500mm & 600mm diameters. Suitable for: Highway surface water carrier and filter drains Private surface water applications
150x110mm branch UMY10Q 150mm surface water sewer ULS13/ULS16 150mm foul sewer ULS13/ULS16
(i) 18% greater capacity than 375mm concrete (ii) over 50% greater capacity than 400mm concrete
Available in 400mm(i), 500mm(ii) and 600mm diameters. Half slotted versions available in 400mm and 500mm diameters. Meets the requirements of The Specification for Highway works, clause 501-3. BBA 06/H122 certification.
A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695
6 7
underground
Key components
Key components
The Marley underground drainage range offers a comprehensive range of standard fittings including bends, branches and couplings. Pictured is a selection of key components within the range. For a complete listing of the below ground range, see pages 27-31.
Mechanical bend (UB47M)
450x110mm chamber base (UCC3D), riser (UCR3), access ring (UCLRR), lid (UCL35PP) & clip (UCC10D)
450x160mm chamber base (UCC5), riser (UCR2), lid (UCL35PP) & clip (UCC10)
Inspection chambers
250mm and 450mm inspection chambers can be used as an alternative to traditional manholes for standard and deep inspection. See page 16-19 for installation data. (see below ground price list, pages 11-16)
Adjustable bends
Available in 82, 110 and 160mm with a solvent weld joint or as a 110mm mechanical bend. The solvent weld bend can be adjusted by cutting the fitting at the required angle and solvent welding the two sections together. Code UB37 UB47 UB67
250mm chamber (UCC7) & lid (UCL3) 250mm chamber (UCC7) & lid (UCL2)
Angle achieved 11 87 21 90 15 90
The mechanical bend provides a twist and lock solution to achieve the desired angle of between 5 and 30. (see below ground price list, page 7)
A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695
8
underground
Design
Design
Statutory requirements
The following standards deal with drainage design: S EN 752: Parts 1-7:1997 Drain and sewer systems outside buildings. B S EN 1610: 1998 Construction and testing of drains and Sewers. B The design and layout of drainage and sewerage systems should comply with The Building Regulations and Water Authority Specification. Reference should also be made to the Sewers for Adoption manual. The following information is provided only as a general guide to good practice for the design of underground drainage systems. For full details please consult the relevant documents referred to above. Pipe strength
Quantum Sewer
Physical characteristics
Dimensions and weights
Pipe Solid wall BS nominal size (mm) 82 110 160 150 225 300 150 225 300 Min 82.4 110.0 160.0 145 226 297 148 230 302 Max 82.7 110.3 160.4 160 250 330 160 250 330 Wall thickness (mm) 3.0 3.2 4.0 Weight kg/metre 1.2 1.7 3.0 1.85 4.20 7.00 1.25 2.75 4.65
Quantum Highway
Means of access
Access is required to drainage installations for testing, inspection and removal of debris. Access to drainage allowing rodding in both directions can be provided by inspection chambers, manholes and other access fittings. Rodding eyes provide access for clearance of debris in the direction of flow only and should thus be used in conjunction with an access chamber or manhole at a point downstream. No part of the drain or sewer should be more than 50m away from a manhole. The distance between points should therefore not exceed 100m.
Access fitting 1 2 To branch or junction Shallow inspection chamber Manhole or deep inspection chamber
Pipe strength
Pipe type Marley solid wall Marley solid wall Quantum Sewer Quantum Highway Quantum Sewer Quantum Highway
For full guidance as to provision of access, reference should be made to BS EN 752 Part 3: 1997. The table below details the maximum spacing of the access points as detailed in the above standard.
Minimum short-term ring stiffness Minimum short-term ring stiffness Minimum two-year ring stiffness
Gradients
Foul water drainage systems are generally designed to run at a maximum of three quarters full bore. Pipe gradients should be established such that the velocity does not fall below 0.70 l/s to ensure adequate self-cleansing. A 110mm foul drain taking the discharge from a single stack should be laid at a 1:40 (25mm per metre) fall. A foul drain taking the discharge from more than one stack can be laid at 1:80 (12.5mm per metre). Gullies incorporating in foul water or combined drainage systems must have a 50mm minimum water seal. >1 Peak flow (a) litres/second <1 PVCu pipe size (mm) 82 110 82 110 160
(a) Peak flow based on probability flow calculation method (b) Minimum 1 WC (c) Minimum 5 WCs
Start of external drain* Rodding eye Type 1 access fitting 150 x 100mm Type 2 access fitting 225 x 100mm Shallow inspection chamber Manhole or deep inspection chamber
* Stack or ground floor appliance
12 22 22 -
12 22 45 -
22 12 22 22 -
22 45 22 45 45 45
45 45 22 45 45 90
Surface water drainage systems may be designed to run full bore. Drains taking multiple rainwater pipes can be laid to a fall of 1:100 (10mm per metre).
A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695
10
The table opposite is taken from BS EN 752-4:1998 and provides guidance on minimum gradients for different size drains.
11
underground
Installation data
installation should be carried out in accordance with BS EN 1610 bedding construction type 1, as shown opposite. Trenches should be excavated to allow for the depth of bedding material. Before any pipework is installed the bedding material should be laid evenly along the bottom of the trench.
300mm 100mm Pipe diameter 50mm or 100mm dependent on in situ soil type and condition
Granular material for bed & surround of PVCu drains and sewers
Suitable imported granular material for bedding and surrounding PVCu solid wall and Quantum Pipes for private and adoptable sewer applications is detailed in the table right: Grading complying with the requirements of BS EN 1610. Granular material also includes aggregates to BS 882, air cooled blast furnace slag to BS 1047 and sintered pulverised fuel ash to BS 3797.
The sidefill material must be the same as the bedding material and extended to the crown of the pipe and be thoroughly compacted. Where the backfill above the pipe contains stones larger than 40mm or where the pipework is deeper than 2m in poor ground, the granular material must extend at least 100mm above the pipe crown. Alternatively, backfill material can be graded to eliminate stones exceeding 40mm and this selected material used for the first 300mm above the pipe. When the pipes are to be laid in rock, compacted sand or gravel, or in very soft or wet ground requiring mechanical means of trimming, the bedding should be a minimum of 100mm.
150/160mm
A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695
12 13
underground
Installation data
Less than 600mm Paving slab Pipe diameter 50mm or 100mm dependent on in situ soil type and condition 75mm min granular material 100mm 100mm min Pipe diameter 100mm
Selected backfill must not contain stones larger than 40mm Bed and surround with suitable granular material
100mm min
For applications in accordance with DTP requirements, please refer to the technical design and installation guide, available to download from marley.co.uk
14 15
underground
Installation data
600mm max
600mm max
A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695
16 17
underground
Installation data
Granular material
UCLRR UCL35PP
UCR3
UCR2 chamber riser UCC3 110mm or UCC5 160mm base UCC10 chamber riser clip
UCC3D or UCC5
The UCC5 160mm chamber base is fully compatible with 150mm Quantum pipe. This is achieved by removing the snap cap and seal from the chamber base and inserting Quantum pipe into the socket, with the seal located into the first corrugation of pipe. 450mm inspection chambers are designed to withstand water testing in accordance with BS EN 1610.
For the installation of an inspection chamber deeper than 1.2m, the regulations require the clear opening to be reduced to 350mm to prevent man entry. Inspection and maintenance should be carried out by remotely operated equipment and the maximum depth is limited to 4m. Access is only permitted when there is no other alternative. For full details please refer to the Building Regulations (England & Wales) Approved Document H Drainage & Waste Disposal April 2002 or Part 3 of the Building (Scotland) Regulations 2004 BSEN 752-4:1998.
The 110mm deep inspection chamber UCC3D incorporates reinforcing ribs on the underside of the chamber and a single UCR3 chamber riser rod welded to the chamber base. Please note that the standard UCC3 chamber base and UCR2 riser are not suitable for deep inspection applications. Featuring increased ring stiffness over our standard inspection chamber riser, the UCR3 deep inspection riser must be used for all deep inspection applications.
Identifiable by tabs marked Deep Inspection on the inside, each riser is 480mm high (effective height 440mm) and is supplied with a 450mm ring seal. The UCR3 must be used in conjunction with the UCC5 or UCC3D inspection chambers for deep inspection. The reduced access ring (UCLRR) fits into the UCL35PP lid and creates the required restricted opening for non-man entry.
A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695
18 19
underground
Installation data
Compact gully
The UG40 compact gully is simple in design, it features a unique design of baffle plate which, when removed,
provides full access to the main body for cleaning and rodding purposes.
UG48 square gully hopper
Where a very shallow invert is required a UB45 110mm x 45 socket/spigot bend can be connected into the gully outlet. The larger boss upstands on the gully accept 68mm rainwater pipe connections and the smaller upstands allow 32, 40 and 50mm pipes to be connected using the appropriate boss connector.
Bottle gully
The UG50 bottle gully is ideal for new or replacement installations and it provides the facility for direct 110mm connections and waste pipe connections via boss adaptors.
32, 40 or 50mm waste pipe UG52 raising piece
rainwater pipe
P trap gully
The double socket design of the UG42 P Trap Gully makes it ideal for use in restricted spaces and allows the trap to be orientated to suit the direction of the outlet pipe. Both the square UG48 and rectangular UG47 hoppers can be connected to the gully using a short length of 110mm pipe cut to suit ground level. The UG45 gully grating can also be used with the UW401 raising piece to receive waste pipe connections below ground level.
SA411, 421, 420 boss adaptor
The fully rotating gully body allows the outlet to be orientated to suit the drain connection. A removable rubber plug provides access for cleaning.
110mm solvent socket
The gully raising piece UG52 allows the gully to be installed at depths up to 520mm.
110mm drain 110mm drain
2. Remove sealing ring from gully frame spigot and place in first corrugation of raising piece.
A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695
20 21
underground
Installation data
40 or 32mm pipe SA421/411 boss adaptor SRM402 reducer 110mm PVCu pipe
50mm pipe SA420 boss adaptor SRM402 reducer 110mm PVCu pipe
UCA40 adaptor
Gaskin
The UMA45 adaptor can be used to connect 160mm solid wall drainage pipes to BS EN 1401: 2000 to 150mm diameter nominal size clayware pipes as shown on page 25.
2:1 sand and cement Gaskin
PVCu pipe socket to thin wall clayware socket
UA41 adaptor
Stoneware socket
UCA40 adaptor
RRM425 reducer
The diameter of 110mm PVCu solid wall above and below ground drainage systems are the same and therefore direct connection may be achieved without an adaptor.
SRM325 reducer
A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695
22 23
underground
Installation data
Pipe socket or coupling 150mm Quantum pipe UME15Q coupling 160mm solid wall pipe
Quantum seal fitted in first corrugation of pipe and handed as shown
Flexible couplings
The range of flexible couplings allow connections to be made between Quantum pipes and pipes of other materials.
A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695
24
25
underground
British & European Standards
BS 6209: 1982, Specification for solvent cement for non-pressure thermoplastic pipe systems. BS 7158: 2001, Plastic inspection chambers for drains and sewers. BS EN 124: 1994, Manhole covers and frames. BS EN 295: 1991, Vitrified clay pipes & fittings and pipe joints for drains and sewers. BS EN 681-1: 1996, Elastomeric seals. Material requirements for pipe joint seals BS 882: 1992, Specification for Aggregates from natural sources for concrete. BS 1047: 1983, Specification for Air-cooled blast furnace slag aggregate for use in construction. BS 4660 & BS EN 1401: 1999, Plastic piping systems for non-pressure underground drainage and sewerage. Unplasticised polyvinyl chloride (PVCu). BS 4962: 1989, Specification for plastic pipes and fittings for use as subsoil field drains. BS 5955-6: 1980, Plastics pipework (thermoplastics materials). Code of practice for the installation of unplasticised PVC pipework for gravity drains and sewers. used in water and drainage applications. Vulcanised rubber. BS EN 752: Parts 1-7: 1997, Drain & Sewer Systems outside buildings. BS EN 1295-1: 1998, Structural design of buried pipelines under various conditions of loading. General requirements. BS EN 1610: 1998, Construction & Testing of Drains & Sewers. BS EN 12056-2: 2000, Gravity drainage systems inside buildings: Sanitary pipework, layout and calculation. BS EN 12056-3: 2000, Gravity drainage systems inside buildings. Roof drainage, layout and calculation. BS EN ISO 9001-2: 2000, Quality management systems.
D TIFIE TO W ER
ER INDUSTR AT ER INDUSTR AT
BBA 88/1977, Marley Underground Drainage System. BBA 92/R070, Quantum Highway PVCu Twinwall Drainage System. BBA 94/2985, Marley Quantum Sewer PVCu Twinwall Underground Drainage and Sewerage System. BBA 98/3486, Marley Quantum Highway PVCu Twinwall Surface Water Drainage System. WIS 4-08-01, Imported granular and selected as-dug bedding and sidefill materials for buried pipelines. WIS 4-35-01: 2000, Specification for Structured Wall Pipes: Joints & Couplers.
Code
Description
Size
(mm)
Code
Description
Size
(mm)
Code
Pipe
3m 6m 6m 3m 3m 3m 6m 6m 110 110 160 82 110 160 110 160 UL403 UL406 UL606 UP303 UP403 UP603 UP406 UP606
Equal branches
ribbed 87 Socket/spigot
UY401R
110
UY401R
Double spigot
45 45
All Socket 110 UB455R ribbed 45 87 87 ribbed 87 UB37 UB47 UB67 All socket 110 UY466R
Perforated pipe
UY466R
Straight couplings
Push fit polypropylene ring seal (Supplied in U.V. resistant polythene bags)
D TIFIE TO W ER
Adjustable bends
11 87 82 21 90 110 15 90 160 Socket should be solvent welded
110 UE406 160 UME15C Push fit coupling 82 UE305 110 UE405 160 UME16C 82 110 160 110 UE300 UE400 UE600 UE402
Unequal branches
45 160x110 UY66
Y
ECIFICAT SP I
WIS 4-35-01
FM30637
26
Certificate No.
Mechanical bend
5-30 110 UB47M 87 160x110 UY64
ON
Socket/spigot
ON
Unequal branches
45 160x110 UMY10C
160x110 UMY12C
Equal branches
45 45 45 ribbed 45 87 87 82 110 160 110 UY36 UY46 UY63 UY46R
All socket
Access pipe
110 UF42
27
underground
Solid Wall Product information
Description Size
(mm)
Code
Description
Size
(mm)
Code
Description
Size
(mm)
Code
Description
Size
(mm)
Code
Description
Size
(mm)
Code
Description
Size
(mm)
Code
Bottle gully
Bottle gully Bottle gully with back inlet open 110 UG50D 110 UG50
Grating components
Grating assembly Spare grating suits UG40, 45, 47 & 48 Spare back plate suits UG40 & UG47 110 UG45
Socket/spigot
Access branches
45 equal Left hand 45 equal Right hand Socket/spigot 110 UY471
450
SR450
Bottle gully with sealed access lid 110 UCB48L A15 loading UG50SA
110 110
UG46 UG49
110
UY472
For use with UCC3D or UCC5 when invert depth is greater than 1.2m. Max invert depth 4m 480mm high. Includes one 450mm seal
Slipper bends
Rodding point
45 45 Socketed with black cover 110 160 URP1 URP2C
Left hand 45 Right hand 110 USB42 For use with UG50 bottle gully
Provides 350mm restricted opening. Snap lock connection to the frame of the UCL35PP
Yard gully
110 UG52 634mm deep x 315mm diameter 110 UYG40
Pressure plug
110 160 UE43 UE64
Compact gully
110 UG40
Adaptors
PVCu pipe socket to salt glazed/pitch fibre pipe socket 110 UA41
Socket plug
110 1 boss upstand SE41
Chamber riser
250 375mm long For use with UAC02 & UAC44 UAR1
Eccentric reducers
82-50 Solvent socket to boss upstand 82-68 SRM325 Solvent socket to 68mm downpipe 110-50 SRM402 250 UCL2 Solvent socket to boss upstand 110-68 URM425 SRM30
P trap gully
110 81 outlet UG42 Salt glazed/cast iron spigot to PVCu spigot Socket/socket to suit thin wall clayware spigot pipe Socket/socket to suit thick wall clayware pipe Rainwater to 110mm drain 110 UA47
110 110
UCA40 UCA41
Lifting handle
110 KP204W
45 outlet
Rectangular hopper
110 UG47 110 UA42
2 boss upstands
Chamber riser
110 400mm high Includes one 450mm seal UCR2
Concentric reducer
110-50 300 UCL3 Spigot to boss upstand SE41
Square hopper
110 UG48
110
UA43
2 boss upstands
UA43/SA110
28
29
underground
Quantum Structured Wall Product information
Description Size
(mm)
Code
Description
Size
(mm)
Code
Description
Size
(mm)
Code
Description
Size
(mm)
Code
Description
Size
(mm)
Code
Description
Size
(mm)
Code
Bends
87 87 87 Double socket 45 45 45 Double socket 30 30 30 Double socket 15 15 15 150 UMB11Q 225 UMB21 UMY21 300 UMB31 150 UMB13Q 225 UMB23 300 UMB33
UMY20
Unequal branch
150 UMB19Q 225 UMB29 300 UMB39 45 225x100 UMY20
Adaptors
150 UMA17
Coupling
600 UME65Q Straight
300x150 UMY31
Bend
45 45 UMD17 UMD27 UMD37 90 litres (760mm deep) 112 litres (920mm deep) 150 150 UMA43 UMA49 400 500 UMB44 UMB54
Flexible coupling
45 225x150 UMY21 150 225 300
45
600
UMB64
45
300x225 UMY32
Rodding point
45 150 URP2Q Double socket
Unequal branch
45 400x225 UMY42 45 500x225 UMY52 45 600x225 UMY62 1kg UMA41 45 400x150 UMY41 45 500x150 UMY51 45 600x150 UMY61
UMB13 - 30 Bend
Double socket
Equal branch
UMB11 - 15 Bend
45 45 45
150
UMJ11 Quantum pipe seal (1) 150 225 300 UMR11 UMR21 UMR31
Socket Plug 87 150 UMY13Q 150 225 300 End Cap UMK11 UMK21 UMK31
Pipe seals
6m 600 UPH66 Quantum pipe seal (1) 400 500 600 UMR41 UMR51 UMR61
Seal to convert Quantum 150mm sockets for use with BS EN 1401 pipe Seal cap to convert Quantum 150mm sockets for use with BS EN 1401 pipe
150
UR61T
Unequal branch
45 150 UME15Q 225 300 UME25 UME35 87 150 UME16Q 225 300 UME26 UME36 Quantum/solid wall PVC to clayware pipe coupler 150x110 UMY12Q 150x110 UMY10Q 300x225 UML32
pipe and fittings. Branches are spigot ended and need to be used in conjunction with couplings and seals.
Couplings
Straight
Coupling
400 UME45Q 500 UME55Q
Slip
30
31
Head Office Lenham, Maidstone, Kent ME17 2DE Telephone: 01622 858888 Fax: 01622 858725 marley.co.uk
Scotland Birkenshaw Industrial Estate Uddingston, Glasgow G71 5PA Telephone: 01698 815231 Fax: 01698 810307
Export Division Lenham, Maidstone Kent ME17 2DE England Telephone: +44 (0)1622 858888 Fax: +44 (0)1622 850778
Further information For Technical advice please call 01622 852695 For general enquiries and details of your nearest stockist please call the customer services department on 01622 852585 email: marketing@marleyext.com