You are on page 1of 22

C o v Licenses e r

for WinCC flexible and Panels

WinCC flexible & Panels


s h FAQ March 2010 e et

Service & Support


Answers for industry.

Question

This entry originates from the Service & Support Portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The conditions of use specified there apply (www.siemens.com/nutzungsbedingungen). Go to the following link to download this document. http://support.automation.siemens.com/WW/view/de/27005215

Question
What should you watch out with regard to licenses for WinCC flexible and panels?

Answer
Follow the instructions and notes listed in this document for a detailed answer to the above question.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

Contents

Contents
Cover sheet ................................................................................................................... 1 1 1.1 1.2 1.3 1.4 2 2.1 2.2 2.3 2.4 3 3.1 3.2 3.3 4 4.1 4.2 4.3 5 5.1 5.2 5.3 6 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 General Information About Licenses ............................................................ 4 License, Certificate of License and License Key .............................................. 4 Why Do You Need Licenses?........................................................................... 4 Available License Types ................................................................................... 5 Licenses for Options and Services of WinCC flexible ES/RT ........................... 6 How Do You Transfer Licenses?................................................................... 7 Which Software Is Needed? ............................................................................. 7 How Do You Transfer License Keys? ............................................................... 9 Transferring License Keys to an Operator Panel via Automation License Manager ..................................................................................................... 10 Removing License Keys from an Operator Panel via Automation License Manager ..................................................................................................... 13 License Key Backup..................................................................................... 16 Which Software Is Needed? ........................................................................... 16 When Do You Have to Back Up License Keys? ............................................. 16 Backup and Restore ....................................................................................... 16 License Upgrades......................................................................................... 17 What Is a License Upgrade and What Types Are There? .............................. 17 Requirements for an Upgrade ........................................................................ 17 Upgrading Using the Automation License Manager ....................................... 18 Special Features of WinAC MP.................................................................... 20 License Keys for WinAC Types ...................................................................... 20 License Keys for WinAC Versions .................................................................. 20 Other Special Features................................................................................... 20 Frequently Asked Questions ....................................................................... 21 How Do You Repair a Defective License?...................................................... 21 Why is a License Invalid After Changing Time Zones? .................................. 21 Why are License Keys Not Recognized? ....................................................... 21 Where is the "Old" License Key Located after an Upgrade? .......................... 21 How Do You Retrieve a Lost License Key? .................................................... 21 Why are Licenses from a Panel Not in the Backup? ...................................... 22 Can You Use a License for WinCC flexible 2008 also for WinCC flexible 2007?22 Can You Change the Versions of WinCC flexible by Replacing Licenses? (This does not apply for Micro and China Editions) ............................................ 22

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

1 General Information About Licenses

1
1.1

General Information About Licenses


License, Certificate of License and License Key
Each edition of WinCC flexible is subject to license. Specific editions of WinCC flexible require a license to enable unrestricted utilization. License: A license is granted as the authorization to utilize products. A license consists of the CoL and the License Key, which represent the authorization for utilization. CoL- Certificate of License: The CoL is a confirmation in writing (evidence) of the license. It documents the owner of the license in the legal sense and contains the license number for unique identification of the license. License Key: The License Key is the "technical representation" of the license (electronic license stamp). Authorization The Authorization is the predecessor of the License Key.

Note

CoL: You receive the license in paper form. The license authorizes you to install on a computer and use the edition of WinCC flexible purchased. License Key: You receive the License Key on a separate, copy-protected USB stick.

1.2

Why Do You Need Licenses?


You install a License Key or Authorization in the following cases: For using the WinCC flexible Engineering System. For using options of the WinCC flexible Engineering System. For using WinCC flexible Runtime. For using options of WinCC flexible Runtime on PC-based operator panels. For using options on non-PC-based operator panels.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

1 General Information About Licenses

You uninstall a License Key or Authorization in the following cases: When you save data. When you no longer need the license.

1.3

Available License Types


The WinCC flexible Engineering System uses the following license types: Floating License Trial License

WinCC flexible Runtime and options Runtime use the following license type: Single License

Floating License Standard license for WinCC flexible Engineering System. Unlimited time license that you can use locally or via the network on any computer. Can be upgraded.

Single License Trial License One-off, limited time standard license that you can install and use locally on any computer. All licenses for WinCC flexible Runtime and Runtime options are Single Licenses. Unlimited time standard license that you can only install and use locally. Can be upgraded.

Upgrade License With the Upgrade License, you can do the following, for example:
Note

Switch from an old version to a new version (the requirement here is that the new version is already installed). Extend the quantity framework. A License Key cannot be copied. The copy-protection procedure used prevents the copying of License Keys.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

1 General Information About Licenses

1.4

Licenses for Options and Services of WinCC flexible ES/RT


Different licenses are needed for the various options and services in Runtime, such as "Sm@rtService" or the application "Recipes for PC Runtime Systems". The document attached (License_Key_List_e_V1_1.pdf) lists the licenses required for the various options and services in the WinCC flexible Runtime (RT) and in the WinCC flexible Engineering System (ES).
Table 1-1

WinCC flexible option Option WinCC flexible / ChangeControl WinCC flexible / Sm@rtService WinCC flexible / Sm@rtAccess WinCC flexible / OPC server WinCC flexible / Audit WinCC flexible / ProAgent WinCC flexible / Recipes WinCC flexible / Archives WinCC flexible / SIMATIC Logon SIMATIC WinAC MP RT O O O O O O O O O ES O 2004 X X X X X X X -

WinCC flexible 2005 X X X X X X X X X 2007 X X X X X X X X X X 2008 X X X X X X X X X X

Key: X Available - Not available o Option of WinCC flexible Runtime or WinCC flexible Engineering System
Note

Please refer to the relevant compatibility lists for the compatibility of the WinAC MP option.
WinCC flexible 2004 WinCC flexible 2005 WinCC flexible 2005 ASIA WinCC flexible 2007 WinCC flexible 2008 BID 22055716 BID 22056585 BID 23499669 BID 26998997 BID 31592453

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

2 How Do You Transfer Licenses?

2
2.1

How Do You Transfer Licenses?


Which Software Is Needed?
You need the following software for handling License Keys and Authorizations. The Automation License Manager (for License Keys and Authorizations). AuthorsW (predecessor of the Automation License Manager, only for Authorizations).

As from WinCC flexible 2005, the new License Keys are used instead of the authorizations used previously. These License Keys are organized with the Automation License Manager. The Automation License Manager offers greater user comfort than AuthorsW and ProSave and many new functions. Here is a summary of the individual utilities and how they are used.
Table 2-1

Authorization: Windows CEbased systems AuthorsW ProSave Automation License Manager -X -PC-based systems X -X

Licenses: Windows CEbased systems --X PC-based systems --X

Description of the individual software tools: Automation License Manager: You can use the Automation License Manager to install or uninstall license keys for PC and Windows CE-based target devices. You can use the Automation License Manager to install or uninstall authorizations for PC-based target devices. Operator panels (other than PC-based operator panels) that are only supported as from WinCC flexible 2005, such as OP 177B, only support License Keys and can therefore only be transferred with the Automation License Manager. You cannot use the Automation License Manager to transfer authorizations to Windows CE-based target devices. That is only possible with ProSave.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

2 How Do You Transfer Licenses?

ProSave: You can use ProSave to transfer existing authorizations to Windows CE-based target devices and from the operator panel back to the authorization disk. You cannot use ProSave to transfer License Keys (for WinCC flexible 2005, for instance). More information about how to use ProSave is available in the Online Help.

AuthorsW: You can use AuthorsW to install or uninstall existing authorizations for PC-based target devices. You cannot use AuthorsW to transfer License Keys (for WinCC flexible 2005, for instance). More information about how to use AuthorsW is available in the Online Help.

Note

The transfer of License Keys to Windows CE-based target devices is supported as from version V2.1 (included in the delivery package of WinCC flexible 2005, for instance). If you use an older version of the Automation License Manager, such as the version in STEP 7 V5.1 SP2, you also have to install the WinCC flexible 2005 or ProSave software. You can download ProSave in Entry ID 10347815.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

2 How Do You Transfer Licenses?

Note

As from WinCC flexible 2005 (Compact, Standard, Advanced or Runtime for PC systems or an options package for WinCC flexible 2005), you receive the associated License Key upon purchase. When you transfer a license key to the hard drive or to an operator panel, it enables the relevant functions for permanent use without any restrictions. The new License Keys are used instead of the authorizations used previously. You can continue to use existing authorizations for WinCC flexible 2004 Runtime and Runtime options (Sm@rt-Access, for example) in WinCC flexible 2005. Exception: Operator panels (other than PC-based operator panels) that are only supported as from WinCC flexible 2005, such as OP 177B. If you possess a runtime license for a PC system for WinCC flexible 2004, this license can also run in WinCC flexible 2005. However, bear in mind that for legal reasons you have to use a new license for WinCC flexible 2005 or need to upgrade the WinCC flexible 2004 license to WinCC flexible 2005! Runtime options are not affected by this.

2.2

How Do You Transfer License Keys?


The Automation License Manager provides the following options for transferring License Keys between different storage locations (computers, USB memory sticks, for instance): 1. Drag and drop 2. Cut and paste 3. Menu command "License Keys > Transfer"
Note

Refer to Entry ID 19109408 for which transfer and connection options are available for the separate operator panels.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

2 How Do You Transfer Licenses?

2.3

Transferring License Keys to an Operator Panel via Automation License Manager


When you install WinCC flexible 2005 or ProSave V7.2, you can transfer license keys to an operator panel with the aid of the Automation License Manager. You can find out below how to transfer a license key from a PC to an MP370 operator panel and how to remove an existing license key from an operator panel.

Opening the Automation License Manager Open the Automation License Manager via "Start > SIMATIC > License Management > Automation License Manager".
Figure 2-1

Connecting the target system with the Automation License Manager and selecting the connection type Click "Edit > Connect Target System > Connect Panel" to go to the "Connect Target System" menu. Select the appropriate operator panel and connection type there. Bear in mind that the transfer settings in the Automation License Manager and on the target device must match. The operator panel selected determines which connection types are supported. In this case, we have selected the MP370 and the "MPI/PROFIBUS" transfer path.
Note

Also check the interface parameterization used in the PG/PC interface and change this accordingly.

10

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

2 How Do You Transfer Licenses?

Figure 2-2

Click OK to confirm the entries. The selected operator panel (MP370) also appears in the project tree.

Note

If the operator panel does not appear and there is no error present, then press the F5 key (to refresh the display).
Figure 2-3

Selecting the data medium with License Keys Select the drive, "Drive A", for example, where the license key is located. Other data media can also be used, a USB stick, for example. Select the menu item "License Keys" in the available standard views. All the license keys that are available on the drive now appear. In this case, all the license keys on the "A" drive.
Figure 2-4

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

11

2 How Do You Transfer Licenses?

Transferring License Keys Select the license key which you would like to transfer to the operator panel. Right-click and select the menu item "Transfer...".
Figure 2-5

In the following pop-up menu, select the "target destination" to which the license key is to be transferred. The License Key is then transferred.
Figure 2-6

Figure 2-7

12

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

2 How Do You Transfer Licenses?

Once the license key has been transferred, you can check this in the Automation License Manager. In order to do this, highlight the operator panel and select the menu item "License Keys" in the available standard views. All the license keys that are available on the drive now appear.
Figure 2-8

Note

You can also transfer License Keys to the panel without WinCC flexible. More information about this is available in Entry ID 23238814.

2.4

Removing License Keys from an Operator Panel via Automation License Manager

Opening the Automation License Manager Open the Automation License Manager via "Start > SIMATIC > License Management > Automation License Manager".
Figure 2-9

The Automation License Manager opens. Connecting the target system with the Automation License Manager and selecting the connection type Click "Edit > Connect Target System > Connect Panel" to go to the "Connect Target System" menu. Select the appropriate operator panel and connection type there. Bear in mind that the transfer settings in the Automation License Manager and on the target device must match.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

13

2 How Do You Transfer Licenses?

The operator panel selected determines which connection types are supported. In this case, we have selected the MP370 and the "MPI/PROFIBUS" transfer path.
Note

Also check the interface parameterization used in the PG/PC interface and change this accordingly.
Figure 2-10

Click OK to confirm the entries. The selected operator panel (MP370) also appears in the project tree.
Note

If the operator panel does not appear and there is no error present, then press the F5 key (to refresh the display).
Figure 2-11

In the Automation License Manager highlight the operator panel from which you wish to delete the license key and select the "License Key" option in the available standard views. All the license keys that are available on the drive now appear.
Figure 2-12

14

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

2 How Do You Transfer Licenses?

Removing License Keys Highlight the license key which you wish to delete from the operator panel. Right-click and select the menu item "Transfer...".
Figure 2-13

In the following pop-up menu, select the "target destination" to which the license key is to be transferred. In this case, the "A" drive. The License Key is then transferred. Other data media can also be used as target destination, a USB stick, for example.
Figure 2-14

Figure 2-15

Note

Ensure beforehand that the transfer parameters are correctly set on the panel and that the operator panel is in "Transfer mode. Always keep the original storage location of the License Keys or the original Authorization floppy disks.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

15

3 License Key Backup

3
3.1

License Key Backup


Which Software Is Needed?
You can save and move the License Keys you purchase. You have two options in the case of panels: ProSave Automation License Manager

You can use the Automation License Manager to save License Keys for software. Follow the instructions in the section "2.4 Remove License Keys from the operator panel via Automation License Manager".

3.2

When Do You Have to Back Up License Keys?


You must save the License Keys under the following circumstances: When you install a new operating system. Before you format the hard disk. Before you compress the hard disk. Before you restore the hard disk. When you start an optimization program that moves fixed blocks. Before you run a backup / restore procedure. Before booting.

3.3

Backup and Restore


Refer to Entry ID 28928853 for how to do a backup /restore. Whether the License Keys are saved during a backup procedure depends on your operator panel. Authorizations and License Keys are lost when you do a "complete" backup/restore. Exception: The License Keys are saved when you do a complete backup on the following operator panel series. OP/TP 177B Mobile Panel 177 OP/TP 277 Mobile Panel 277 MP 377

16

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

4 License Upgrades

4
4.1

License Upgrades
What Is a License Upgrade and What Types Are There?
If you have to upgrade a License Key or an "old Authorization" for using a new software version, then you must distinguish between the following options:
Note

Upgrade of a License Key to a new License Key. Upgrade of an Authorization to a License Key. Upgrade of an Authorization to a more recent Authorization. You cannot install upgrade license keys during Setup.

4.2

Requirements for an Upgrade


For upgrading a license key or an "old authorization": Of the software version to be upgraded: or An "old Authorization on an authorization floppy disk The CoL (Certificate of License) and the License Key

Of the target version: or The Upgrade Authorization on an authorization floppy disk The CoL and the Upgrade License Key

Note

Please note that both the "old" Authorization and the "old" License Key as well as the upgrade itself must be stored on the hard disk of the computer on which the upgrade is to be made.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

17

4 License Upgrades

4.3

Upgrading Using the Automation License Manager


Proceed as follows to upgrade a License Key (in following referred to only as License Key, even if the source or target is an Authorization). 1. Select the menu command View > Administration 2. Select the storage location in the navigation area where the license key to be upgraded is located.
Figure 4-1

3. In the Object area you select the license key that is to be upgraded. 4. Execute the menu command License Key > Upgrade.
Figure 4-2

Figure 4-3

18

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

4 License Upgrades

The old License Key has now been replaced. Only one License Key is visible.
Figure 4-4

Note

If there is only one option for upgrading, then the upgrade is made without any other displays or prompts. If other upgrade options are found, the "License Key Upgrade" dialog opens. Select the upgrade to be made and click on the "Upgrade" button.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

19

5 Special Features of WinAC MP

5
5.1

Special Features of WinAC MP


License Keys for WinAC Types
The License Key is assigned to a specific operator panel. You cannot use the License Key of an operator panel of the higher performance range, MP 277, for example, with an operator panel of the lower performance range, MP 277, for example. It is possible to transfer with the ALM, but the License Key is not recognized.

5.2

License Keys for WinAC Versions


License Keys of WinAC MP versions are upwards compatible. (Example: You can use the WinAC MP license 2007 also for 2008.)

5.3

Other Special Features


You have to use the ALM to upload the license to the MP. You can store multiple licenses of the same type simultaneously on one panel, but it is of no use.

20

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

6 Frequently Asked Questions

6
6.1

Frequently Asked Questions


How Do You Repair a Defective License?
A license is deemed to be defective in the following cases: If the License Key can no longer be accessed in the storage location. If the License Key disappears when being transferred to the target drive.

You can use the Automation License Manager to repair a defective License Key. For this, use the "Restore" function or the "Restore Wizard" of the Automation License Manager. You must get in touch with Customer Support if you want to restore a license.
Note

The Runtime software runs perfectly even if the license is missing or defective. The system displays a message at short intervals informing you of the unlicensed mode.

6.2

Why is a License Invalid After Changing Time Zones?


The installed license no longer functions if you switch from a time referred to a full hour to a time not referred to a full hour. Example: You switch the time zone from GMT +3:00 hours to GMT +3:30 hours. Remedy: Uninstall the License Key with a time zone setting that was set before you installed the License Key and reinstall the License Key with the new time zone setting.

6.3

Why are License Keys Not Recognized?


In this case, the reason might be an upgrade license. You might have installed the License Key, but have not yet made an upgrade. Help on this topic is available under "Upgrading Licenses".

6.4

Where is the "Old" License Key Located after an Upgrade?


If you want to upgrade an existing system, you can purchase an upgrade. When you make an upgrade, the existing Authorizations or License Keys are replaced by the new License Keys of the upgrade.

6.5

How Do You Retrieve a Lost License Key?


You must make sure that you have the CoL in order to receive a new License Key. This is evidence that you are the owner of the license in the legal sense.

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

21

6 Frequently Asked Questions

You must get in touch with Customer Support if you want to restore a license.

6.6

Why are Licenses from a Panel Not in the Backup?


In the case of certain panels, the licenses are backed up also with a "Complete Backup". You can find additional information about this under "3.3Spare Parts Backup and Restore".

6.7

Can You Use a License for WinCC flexible 2008 also for WinCC flexible 2007?
Yes, it is possible to use all the functions of WinCC flexible without any warnings.

6.8

Can You Change the Versions of WinCC flexible by Replacing Licenses? (This does not apply for Micro and China Editions)
Yes, this is possible. The WinCC flexible software is always the same. When you start the software, the license is queried and the software functions are changed to match the scope of the license. As from WinCC flexible 2007 it is thus possible to change the software versions by uninstalling and installing License Keys. The software does not have to be reinstalled.

22

Umgang mit Lizenzen V 1.2, Entry ID: 27005215

You might also like