ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment
Daikin units comply with the European regulations that guarantee the safety of the product.
Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.
Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products.
.................................................................................
Specifications
.......................................................................
Technical specifications
3 4 5 6
.....................................................
13 15 17 19
..................................................................
.................................................................
..........................................................................
Accessories
..........................................................................
24
8 9 10
..................................................................
25 27 28
................................................................
............................................................................
Features
+ Up to 4 indoor units can be connected to 1 Multi outdoor unit. All indoor units are individually controllable with remote control and do not need to be installed in the same room. They operate simultaneously within the same cooling or heating mode. + The outdoor unit can easily be mounted on a roof, a terrace or placed against an outside wall. + Outdoor units are fitted with a swing compressor, renowned for its low noise and energy efficiency. + The remote control has a 24 hour timer + The indoor model also has a start/stop button mounted on the front panel + Up to 5 indoor units can be operated from a single centralised control + Purpose designed holder provided for your remote control
1
1
+ Flat front panel: its stylish appearance fits easily within any interior dcor and is more easy to clean. + Lightweight and compact + The movement sensor saves power consumption in unoccupied rooms. + The home leave operation saves energy during absence. + Automatic horizontal and vertical auto-swing ensures uniform air flow and temperature distribution. + 3D-air flow (50,60,71 class only) + Powerful mode can be selected for rapid cooling or heating. + Air purification filter with photocatalytic deodorising function - deodorises the air - powerful decomposes cigarette and pet odours - removes house dust and pollen - deactivates bacteria and viruses + Indoor / outdoor unit silent operation Silent buttons on the remote control lower the operating sound of the indoor and/or outdoor unit by 3dB(A) each. + Night quiet mode automatically reduces the operating sound of the outdoor unit by 3dB(A) at night. multi outdoors in cooling mode only
2 3 r 0
Standard Optional 5 steps
q 7 x 8 6 0 6 4
MKS/MXS (cooling appl. only)
FTXS
FTKS
z !
Split - Sky Air Indoor units
Specifications
1
NOMINAL CAPACITY and NOMINAL INPUT
For indoor units only: INDOOR UNITS NOMINAL INPUT Cooling nominal kW FTKS20CVMB 0.04 FTKS25CVMB 0.04 FTKS35CVMB 0.04
For combination indoor + outdoor units (air cooled): INDOOR UNITS OUTDOOR UNITS - PAIR APPLICATION NOMINAL CAPACITY (2-3) Cooling (1) min.nom.max. NOMINAL INPUT Cooling min.nom.max. EER ENERGY LABEL Cooling ANNUAL ENERGY Cooling CONSUMPTION OUTDOOR UNITS - PAIR APPLICATION NOMINAL CAPACITY (2-3) Cooling (1) min.nom.max. NOMINAL INPUT Cooling min.nom.max. EER ENERGY LABEL Cooling ANNUAL ENERGY Cooling CONSUMPTION OUTDOOR UNITS - MULTI APPLICATION
kW kW
kWh kW kW
FTKS20CVMB RKS20CVMB 1.32.03.0 0.300.500.98 4.00 A 250 RKH20CVMB 1.32.02.6 0.430.620.945 3.23 A 310
FTKS25CVMB RKS25CVMB 1.32.53.0 0.300.6950.98 3.60 A 347.5 RKH25CVMB 1.32.253.0 0.430.701.20 3.21 A 350
FTKS35CVMB RKS35CVMB 1.43.43.8 0.301.061.30 3.21 A 530 RKH35CVMB 1.43.153.8 0.461.0451.425 3.01 B 522.5 4MKS58,75,90B
kWh
TECHNICAL SPECIFICATIONS
For indoor units only: INDOOR UNITS DIMENSIONS Unit H W D mm mm mm kg dB(A) dB(A) dB(A) dB(A) m3/min m3/min m3/min rpm rpm rpm W mm FTKS20CVMB FTKS25CVMB 273 784 195 7.5 White 38 25 22 56 7.7 4.2 3.6 5 steps, silent and auto 1,340 1,090 840 Cross flow fan 18 ML fin - J7Hi - XA tube 2 x 12 x 1.4 Removable/washable/mildew proof Microcomputer control J 6.4 J 9.5 J 18.0 Both liquid and gas pipes See chapter RKS-C/RKH-C See chapter MKS-B
3D044242B 3D044243B 3D044244B
FTKS35CVMB
FAN
high low super low high low super low steps high medium low
Speed
mm mm mm
Specifications
1
2
NOMINAL CAPACITY and NOMINAL INPUT
For indoor units only: INDOOR UNITS NOMINAL INPUT Cooling nominal kW FTKS50BVMB 0.04 FTKS60BVMB 0.04 FTKS71BVMB 0.045
For combination indoor + outdoor units (air cooled): INDOOR UNITS OUTDOOR UNITS - PAIR APPLICATION NOMINAL CAPACITY (2-3) Cooling (1) min.nom.max. NOMINAL INPUT Cooling min.nom.max. EER ENERGY LABEL Cooling ANNUAL ENERGY Cooling CONSUMPTION OUTDOOR UNITS - MULTI APPLICATION
kW kW
kWh
FTKS60BVMB RKS60BVMB9 0.906.006.70 0.452.122.45 2.83 C 1,060 4MKS75,90B For more information, see chapter MKS-B
TECHNICAL SPECIFICATIONS
For indoor units only: INDOOR UNITS DIMENSIONS Unit H W D mm mm mm kg dB(A) dB(A) dB(A) dB(A) m3/min m3/min m3/min rpm rpm rpm W mm FTKS50BVMB 290 795 238 9 44 35 32 63 11.4 8.0 7.1 1,340 1,180 1,010 40 2 x 16 x 1.4 FTKS60BVMB 290 1,050 238 12 FTKS71BVMB
FAN
high low super low high low super low steps high medium low
Speed
White 45 36 33 63 16.2 11.4 10.2 5 steps, silent and auto 1,330 1,170 1,010 Cross flow fan ML fin - J8Hi - XA tube 2 x 16 x 1.4 Removable/washable/mildew proof Microcomputer control J 6.4 J 18.0 Both liquid and gas pipes See chapter RKS-B See chapter MKS-B
mm mm mm
J 12.7
J 15.9
Specifications
1
ELECTRICAL SPECIFICATIONS
For indoor units only: CURRENT Nominal running current Maximum running current For combination indoor units + outdoor units:
cooling cooling
A A
FTKS20CVMB 0.18
FTKS25CVMB 0.18 See chapter RKS-C: electrical data FTKS25CVMB RKS25CVMB 3.9 See chapter RKS-C: electrical data
FTKS35CVMB 0.18
Nominal running current cooling cooling Maximum running current Starting current cooling For combination indoor units + outdoor units: CURRENT Nominal running current Maximum running current Starting current cooling cooling cooling
CURRENT
A A A
A A A
For combination indoor units + outdoor units: CURRENT Nominal running current Maximum running current Starting current cooling cooling cooling A A A
FTKS20CVMB
FTKS35CVMB
For indoor units only: POWER SUPPLY NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Voltage
Hz V
FTKS20CVMB VM 1 50 230
FTKS25CVMB VM 1 50 230
FTKS35CVMB VM 1 50 230
3D044242B 3D044243B 3D044244B
NOTES
1 2 3 4 5 6 7 8 Nominal cooling capacities are based on: indoor temperature 27CDB/19CWB * outdoor temperature 35CDB * refrigerant piping length: 7.5m * level difference: 0m. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. The sound power level is an absolute value indicating the power which a sound source generates. Energy label: scale from A (most efficient) to G (less efficient). The Energy Label Directive 2002/31/EC will enter into force once the relevant measurement standard will be published in the European Official Standard. Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)
Specifications
1
2
ELECTRICAL SPECIFICATIONS
For indoor units only: CURRENT Nominal running current Maximum running current For combination indoor units + outdoor units: CURRENT Nominal running current Maximum running current Starting current cooling cooling cooling A A A cooling cooling A A FTKS50BVMB 0.18 FTKS60BVMB 0.18 See chapter RKS-B: electrical data FTKS60BVMB RKS60BVMB9 9.3 See chapter RKS-B: electrical data FTKS50BVMB 4MKS58,75,90B FTKS60BVMB 4MKS75,90B See chapter MKS-B: electrical data FTKS71BVMB 4MKS90B FTKS71BVMB 0.20
For combination indoor units + outdoor units: CURRENT Nominal running current Maximum running current Starting current cooling cooling cooling A A A
For indoor units only: POWER SUPPLY NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Voltage
Hz V
FTKS50BVMB VM 1 50 230
FTKS60BVMB VM 1 50 230
FTKS71BVMB VM 1 50 230
3D040781A 3D040782A 3D040783A
NOTES
1 2 3 4 5 6 7 8 Nominal cooling capacities are based on: indoor temperature 27CDB/19CWB * outdoor temperature 35CDB * refrigerant piping length: 7.5m * level difference: 0m. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. The sound power level is an absolute value indicating the power which a sound source generates. Energy label: scale from A (most efficient) to G (less efficient). The Energy Label Directive 2002/31/EC will enter into force once the relevant measurement standard will be published in the European Official Standard. Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)
Specifications
1
NOMINAL CAPACITY and NOMINAL INPUT
For indoor units only: INDOOR UNITS NOMINAL INPUT Cooling Heating nominal nominal kW kW FTXS20CVMB 0.04 0.04 FTXS25CVMB 0.04 0.04 FTXS35CVMB 0.04 0.04
For combination indoor + outdoor units (air cooled): INDOOR UNITS OUTDOOR UNITS - PAIR APPLICATION NOMINAL CAPACITY (3-4) Cooling (1) min.nom.max. Heating (2) min.nom.max. NOMINAL INPUT Cooling min.nom.max. Heating min.nom.max. EER Cooling COP Heating ENERGY LABEL Cooling Heating ANNUAL ENERGY Cooling CONSUMPTION INDOOR UNITS OUTDOOR UNITS - PAIR APPLICATION NOMINAL CAPACITY (3-4) Cooling (1) min.nom.max. Heating (2) min.nom.max. NOMINAL INPUT Cooling min.nom.max. Heating min.nom.max. EER Cooling COP Heating ENERGY LABEL Cooling Heating ANNUAL ENERGY Cooling CONSUMPTION OUTDOOR UNITS - MULTI APPLICATION
kW kW kW kW
kWh
FTXS20CVMB RXS20CVMB 1.32.02.6 1.32.74.5 0.300.500.98 0.290.6751.46 4.00 4.00 A A 250 FTXS20CVMB RXH20CVMB 1.32.02.6 1.32.64.0 0.430.620.945 0.350.761.31 3.23 3.42 A B 310
FTXS25CVMB RXS25CVMB 1.32.53.0 1.33.44.5 0.300.6950.98 0.290.9351.46 3.60 3.64 A A 347.5 FTXS25CVMB RXH25CVMB 1.32.53.0 1.32.854.5 0.430.701.20 0.350.8351.61 3.21 3.41 A B 350 2MXS40/3MXS52/4MXS68/80B For more information, see chapter MXS-B
FTXS35CVMB RXS35CVMB 1.43.43.8 1.44.05.0 0.301.061.30 0.311.171.59 3.21 3.42 A B 530 FTXS35CVMB RXH35CVMB 1.43.153.8 1.43.65.0 0.461.0451.425 0.4051.0551.90 3.01 3.41 B B 522.5
kW kW kW kW
kWh
Specifications
1
2
NOMINAL CAPACITY and NOMINAL INPUT
For indoor units only: INDOOR UNITS NOMINAL INPUT Cooling Heating nominal nominal kW kW FTXS50BVMB 0.04 0.045 FTXS60BVMB 0.04 0.045 FTXS71BVMB 0.045 0.050
For combination indoor + outdoor units (air cooled): INDOOR UNITS OUTDOOR UNITS - PAIR APPLICATION NOMINAL CAPACITY (3-4) Cooling (1) min.nom.max. Heating (2) min.nom.max. NOMINAL INPUT Cooling min.nom.max. Heating min.nom.max. EER Cooling COP Heating ENERGY LABEL Cooling Heating ANNUAL ENERGY Cooling CONSUMPTION OUTDOOR UNITS - MULTI APPLICATION
kW kW kW kW
kWh
FTXS50BVMB RXS50BVMB 0.905.005.80 0.905.807.50 0.451.662.30 0.451.702.58 3.01 3.41 B B 830 3MXS52/ 4MXS68,80B
FTXS60BVMB RXS60BVMB 0.906.006.70 0.907.008.00 0.452.122.45 0.452.093.10 2.83 3.35 C C 1,060 4MXS68,80B For more information, see chapter MXS-B
FTXS71BVMB RXS71BVMB 0.907.108.00 0.908.509.50 0.452.533.07 0.452.633.80 2.81 3.23 C C 1,265 4MXS80B
Specifications
1
TECHNICAL SPECIFICATIONS
For indoor units only: INDOOR UNITS DIMENSIONS Unit H W D mm mm mm kg dB(A) dB(A) dB(A) dB(A) m3/min m3/min m3/min rpm rpm rpm W mm FTXS20CVMB FTXS25CVMB 273 784 195 7.5 White 38/38 25/28 22/25 56/56 7.7/7.8 4.2/5.3 3.6/4.6 5 steps, silent and auto 1,340/1,300 1,090/1,130 840/960 Cross flow fan 18 ML fin - J7Hi - XA tube 2 x 12 x 1.4 Removable/washable/mildew proof Microcomputer control 6.4 9.5 18.0 Both liquid and gas pipes See chapter RXS-C/RXH-C See chapter MXS-B
3D044245B 3D044246B 3D044247B
FTXS35CVMB
FAN
high low super low Sound power (cooling/heating) high (6) Air flow rate high (cooling/heating) low super low Speed (cooling/heating) steps high medium low Type Motor output Type Rows x stages x fin pitch
38/38 25/28 22/25 56/56 7.7/7.8 4.2/5.3 3.6/4.6 1,340/1,300 1,090/1,130 840/960 18 2 x 12 x 1.4
39/39 26/29 23/26 57/57 7.7/8.1 4.4/5.3 3.8/4.6 1,340/1,340 1,100/1,150 870/960 18 2 x 12 x 1.4
mm mm mm
Specifications
1
2
TECHNICAL SPECIFICATIONS
For indoor units only: INDOOR UNITS DIMENSIONS Unit H W D mm mm mm kg dB(A) dB(A) dB(A) dB(A) m3/min m3/min m3/min rpm rpm rpm W mm FTXS50BVMB 290 795 238 9 44/42 35/33 32/30 63/60 11.4/12.6 8.0/8.9 7.1/7.7 1,340/1,370 1,180/1,200 1,010/1,030 40 2 x 16 x 1.4 FTXS60BVMB 290 1,050 238 12 FTXS71BVMB
FAN
high low super low Sound power (cooling/heating) high (6) Air flow rate high (cooling/heating) low super low Speed (cooling/heating) steps high medium low Type Motor output Type Rows x stages x fin pitch
White 45/44 36/35 33/32 63/62 16.2/17.4 11.4/12.7 10.2/11.4 5 steps, silent and auto 1,330/1,360 1,170/1,200 1,010/1,040 Cross flow fan ML fin - J8Hi - XA tube 2 x 16 x 1.4 Removable/washable/mildew proof Microcomputer control 6.4 12.7 18.0 Both liquid and gas pipes See chapter RXS-B See chapter MXS-B
46/46 37/37 34/34 63/63 16.7/18.5 11.6/13.5 10.6/12.1 1,370/1,440 1,210/1,270 1,040/1,100 43 2 x 16 x 1.4
mm mm mm
15.9
10
Specifications
1
ELECTRICAL SPECIFICATIONS
For indoor units only: CURRENT Nominal running current Maximum running current
A A A A
For combination indoor units + outdoor units: CURRENT Nominal running current Maximum running current Starting current For combination indoor units + outdoor units: CURRENT Nominal running current Maximum running current Starting current cooling heating cooling heating cooling heating A A A A A A cooling heating cooling heating cooling heating A A A A A A
For combination indoor units + outdoor units: CURRENT Nominal running current Maximum running current Starting current cooling heating cooling heating cooling heating A A A A A A
FTXS20CVMB
FTXS25CVMB 2MXS40/3MXS52/4MXS68,80B
FTXS35CVMB
For indoor units only: POWER SUPPLY NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Voltage
Hz V
FTXS20CVMB VM 1 50 230
FTXS25CVMB VM 1 50 230
FTXS35CVMB VM 1 50 230
3D044245B 3D044246B 3D044247B
NOTES
1 2 3 4 5 6 7 8 9 Nominal cooling capacities are based on: indoor temperature 27CDB/19CWB * outdoor temperature 35CDB * refrigerant piping length: 7.5m * level difference: 0m. Nominal heating capacities are based on: indoor temperature 20CDB * outdoor temperature 7CDB/6CWB * refrigerant piping length 7.5m (horizontal) * level difference 0m. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. The sound power level is an absolute value indicating the power which a sound source generates. Energy label: scale from A (most efficient) to G (less efficient). The Energy Label Directive 2002/31/EC will enter into force once the relevant measurement standard will be published in the European Official Standard. Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)
11
Specifications
1
2
ELECTRICAL SPECIFICATIONS
For indoor units only: CURRENT Nominal running current Maximum running current cooling heating cooling heating A A A A FTXS50BVMB 0.18 0.20 FTXS60BVMB 0.18 0.20 See chapter RXS-B: electrical data FTXS50BVMB RXS50BVMB 7.3 7.5 FTXS60BVMB RXS60BVMB 9.3 9.2 See chapter RXS-B: electrical data FTXS71BVMB RXS71BVMB 11.1 11.6 FTXS71BVMB 0.20 0.22
For combination indoor units + outdoor units: CURRENT Nominal running current Maximum running current Starting current cooling heating cooling heating cooling heating A A A A A A
For combination indoor units + outdoor units: CURRENT Nominal running current Maximum running current Starting current cooling heating cooling heating cooling heating A A A A A A
FTXS60BVMB 4MXS68,80B
FTXS71BVMB 4MXS80B
For indoor units only: POWER SUPPLY NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Voltage
Hz V
FTXS50BVMB VM 1 50 230
FTXS60BVMB VM 1 50 230
FTXS71BVMB VM 1 50 230
3D040778A 3D040779 3D040780A
NOTES
1 2 3 4 5 6 7 8 9 Nominal cooling capacities are based on: indoor temperature 27CDB/19CWB * outdoor temperature 35CDB * refrigerant piping length: 7.5m * level difference: 0m. Nominal heating capacities are based on: indoor temperature 20CDB * outdoor temperature 7CDB/6CWB * refrigerant piping length 7.5m (horizontal) * level difference 0m. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. The sound power level is an absolute value indicating the power which a sound source generates. Energy label: scale from A (most efficient) to G (less efficient). The Energy Label Directive 2002/31/EC will enter into force once the relevant measurement standard will be published in the European Official Standard. Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)
12
Dimensional drawings
1
FTK/XS20-25-35C
The mark (Y) shows piping direction
Rear Left Right Air flow (indoor) required space (for performance and maintenance)
(including installation plate)
unit (mm)
Name plate
Signal receiver Room temp. thermistor
Terminal block with earth terminal Gas pipe 9.5Cut (The length of pipe outside the unit: about 300) Liquid pipe J6.4 CuT (the length of pipe outside the unit: about 350) Drain hose (connecting part I.D. J 14.0, O.D. J 18.0) (The hose length on the outside of the unit is approx. 410)
Intelligent movement sensor Timer lamp Operation lamp Indoor unit ON/OFF switch
Signal transmitter
Blade angle
Up/down (automatic) Cooling, dry Heating
Right/left (manual)
3D044026
FTK/XS50B
The mark (Y) shows piping direction
Left Right (including installation plate)
50 MIN
50 MIN
Required space
Terminal block with earth terminal (Inside) Gas pipe 12.7Cut (The length of pipe outside the unit: about 340) Liquid pipe J6.4 CuT (the length of pipe outside the unit: about 350) Drain hose (connecting part I.D. J 14.0, O.D. J 18.0) (The hose length on the outside of the unit is approx. 440)
Bottom
Blade angles
Horizontal blade (Automatic) Cooling
Dry
3D040071
Rear
Rear
30 MIN
unit (mm)
13
Dimensional drawings
1
3
FTK/XS60-71B
The mark (Y) shows piping direction
Left Right (space for maintenance)
50 MIN (including installation plate) 30 MIN 50 MIN
unit (mm)
(space for performance)
Rear
Rear
Required space
Name plate Terminal block with earth terminal Gas pipe J B Cut (The length of pipe outside the unit: about 340)
Operation lamp Signal receiver Indoor unit ON/OFF switch Room temp. thermistor
FTX(K)S6071--
A 6.4
FTX(K)S60-FTX(K)S71--
B 12.7
Drain hose (connecting part I.D. J 14.0, O.D. J 18.0) (The hose length on the Liquid pipe J A Cut (The length of pipe outside of the unit is outside the unit: about 390) approx. 440)
Blade angle
Heating (FTX -- only) Dry
Fan Vertical blade (Automatic) Infrared remote control FTX---: (ARC433A2133) FTK---: (ARC433A22) Wall hole for embedded piping J 80 hole Wall hole J 80 hole
3D040073A
14
Piping diagrams
1
FTK/XS20-25-35C
Indoor unit
Heat exchanger
Field piping
FTK/XS50-60B
Indoor unit
Heat exchanger
Field piping
Field piping
Fan motor
15
Piping diagrams
1
4
FTK/XS71B
Indoor unit
Heat exchanger
Field piping
Field piping
Fan motor
16
Wiring diagrams
1
FTK/XS20-25-35C
Outdoor
g Field wiring
CAUTION
Signal receiver
Note that operation will restart automatically if the main power supply is turned off and then back on again.
R
Infrared remote control
Indoor
C70 FU H1PH3P M1F M1S PCB1PCB3 R1T, R2T S1S36 S1W X1M
: Protective earth : Running capacitor : Fuse : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip
3D033599C
FTK/XS50B
g Field wiring
Rectifier
Outdoor
Transmission circuit
CAUTION
Note that operation will restart automatically if the main power supply is turned off and then back on again.
R
FG FU H1H3 H1PH3P M1F M1S, M2S PCB1PCB5 R1T, R2T S1S38 S1W X1M
Indoor
: Protective earth : Frame ground : Fuse : Harness : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip
3D038065A
17
Wiring diagrams
1
5
FTK/XS60-71B
g Field wiring
Rectifier
Outdoor
Transmission circuit
CAUTION
Note that operation will restart automatically if the main power supply is turned off and then back on again.
R
FG FU H1H3 H1PH3P M1F M1S, M2S PCB1PCB5 R1T, R2T S1S38 S1W X1M
Indoor
: Protective earth : Frame ground : Fuse : Harness : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip
3D038530B
18
6 6-1
Cooling only
Sound level
Sound level data
Sound pressure level
1
6
230V, 50Hz Cooling Measuring location SL 22 22 23 32 33 34
Location of microphone
6-1
L 25 25 26 35 36 37
Heat pump
Sound pressure level Model H FTXS20C FTXS25C FTXS35C FTXS50B FTXS60B FTXS71B 38/38 38/38 39/39 44/42 45/44 46/46 230V, 50Hz Cooling/Heating L 25/28 25/28 26/29 35/33 36/35 37/37 SL 22/25 22/25 23/26 32/30 33/32 34/34
Location of microphone
Measuring location
Sound power level (Cooling/Heating) 56/56 56/56 57/57 63/60 63/62 63/63
6-2
Cooling only
FTKS20-25C
FTKS35C
19
1
6
6-2
6 6-2
FTKS50B
Sound level
Sound pressure spectrum
FTKS60B
FTKS71B
NOTE
1 Operation noise differs with operation and ambient conditions.
20
6 6-2
Heat pump
Sound level
Sound pressure spectrum
1
6
FTXS20-25C (Heating)
FTXS20-25C (Cooling)
6-2
FTXS35C (Cooling)
FTXS35C (Heating)
NOTE
1 Operation noise differs with operation and ambient conditions.
21
1
6
6-2
6 6-2
Sound level
Sound pressure spectrum
FTXS50B (Cooling)
FTXS50B (Heating)
FTXS60B (Cooling)
FTXS60B (Heating)
NOTE
1 Operation noise differs with operation and ambient conditions.
22
6 6-2
Sound level
Sound pressure spectrum
1
6
FTXS71B (Heating)
FTXS71B (Cooling)
6-2
NOTE
1 Operation noise differs with operation and ambient conditions.
23
1
7
7-1
7 7-1
j Mounting plate A
Accessories
Standard accessories
1 2 1 j Remote control holder E j AAA dry-cell G batteries j Indoor unit fixing screws M4x12L H 1 2 2 j Operation manual K j Installation manual L 1 1
FTK/XS20-25-35C
j Air purification filter with photocatalytic deodorising B function j Infrared remote control D
FTK/XS50-60-71B
j Mounting plate A j Air purification filter with photocatalytic deodorising B function j Infrared remote control D
1 2 1
j Remote control holder E j AAA dry-cell G batteries j Indoor unit fixing screws M4x12L H
1 1 2
2 1
7-2
FTK/XS-C/B
Optional accessories
20 Normal open contact Normal open pulse contact 1 up to 5 rooms (2) 25 35 KRP413A1S KRP413A1S KRC72 DCS302C51 DCS301B51 DST301B51 KRP928A2S KAF918A43 KAF918A44 KKF917A4 50 60 71
Option name Wiring adapter for time clock / remote control (1) Centralised control board Central remote control Unified ON/OFF control Schedule timer Interface adapter (3) Air purification filter with photocatalytic deodorising function (with frame) Air purification filter with photocatalytic deodorising function (without frame) Anti-theft protection for remote control
(1) Wiring adapter is also required for each indoor unit. (2) Wiring adapter supplied by Daikin. Time clock and other devices: field supply. (3) Interface adapter for room air conditioners (DIII-NET)
24
8 8-1
Control systems
Infrared remote control
1
8
8-1
FTK/XS20-25-35C
<ARC433A1, A2>
1 2
3 4 5 6 7
Signal transmitter: It sends signals to the indoor unit. Display: It displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation.) HOME LEAVE button: for HOME LEAVE operation POWERFUL button: for POWERFUL operation TEMPERATURE adjustment buttons: It changes the temperature setting ON/OFF button: Press this button once to start operation. Press once again to stop it. MODE selector button: It selects the operation mode (Auto , / Dry I / Cool u / Heat w / Fan B)
8 9 10 11 12 13 14 15 16
OUTDOOR UNIT SILENT button: SILENT operation FAN setting button: It selects the air flow rate setting. SWING button SENSOR button: for INTELLIGENT EYE Operation ON TIMER button OFF TIMER button TIMER setting button: It changes the time setting TIMER CANCEL button: It cancels the timer setting. CLOCK button
25
1
8
8-1
8 8-1
Control systems
Infrared remote control
FTK/XS50-60-71B
<ARC433A21, A22>
1 2
3 4 5 6 7
Signal transmitter: It sends signals to the indoor unit. Display: It displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation.) HOME LEAVE button: for HOME LEAVE operation POWERFUL button: for POWERFUL operation TEMPERATURE adjustment buttons: It changes the temperature setting ON/OFF button: Press this button once to start operation. Press once again to stop it. MODE selector button: It selects the operation mode (Auto , / Dry I / Cool u / Heat w / Fan B)
8 9 10 11 12 13 14 15 16 17
OUTDOOR UNIT SILENT button: SILENT operation FAN setting button: It selects the air flow rate setting. SENSOR button: for INTELLIGENT EYE Operation SWING button Flap (horizontal blade) SWING button Louver (Vertical blades) ON TIMER button OFF TIMER button TIMER setting button: It changes the time setting TIMER CANCEL button: It cancels the timer setting. CLOCK button
26
Center of gravity
FTK/XS20-25-35C
1
9
4D020686H
FTK/XS50B
4D040311
FTK/XS60-71B
4D040313
27
10
10
Installation
FTK/XS20-25-35C
How to attach the indoor unit. Hook the claws of the bottom frame to the mounting plate. If the claws are difficult to hook, remove the front panel. How to remove the indoor unit. Push up the marked area (at the lower part of the front panel) to release the claws. If it is difficult to release, remove the front panel. Front panel
j Mounting plate A
The mounting plate should be installed on a wall which can support the weight of the indoor unit.
Front grille Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipes cut line.
50 mm or more from walls (on both side) (on both side) Air filters Appearance of the indoor unit may differ from some models.
j Air purification filter with photocatalytic B deodorising function Tabs (upper 3 locations)
+ Remove the screws on the service lid. + Slide the service lid leftward. + Rotate the service lid upward.
Before screwing the remote control holder to the wall, make sure that control signals are properly received by indoor unit. j Infrared remote control D
28
10
Installation
10
Indoor unit installation drawings
j Mounting plate A
FTK/XS50-60-71B
The mounting plate should be installed on a wall which can support the weight of the indoor unit. The figure shows a 50 class unit. (See Indoor Unit Installation 1. Installing the mounting plate for details regarding 60 and 71 class units.)
Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipes cut line.
50 mm or more from walls (on both side) (on both side) Air filters Intelligent movement sensor Only for 60 and 70 class units.
Wrap the installation pipe with the finishing tape from bottom to top
Service lid Opening service lid Service lid is opening/closing type. Opening method 1) Remove the service lid screws. 2) Lift the service lid upward.
j Air purifying filter with photocatalytic B deodorizing function. 50 class Tabs (upper 3 locations)
Movement sensor
Caution
1) Do not hit or violently push the movement sensor. This can lead to damage and malfunction. 2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensors detection area.
29