You are on page 1of 5

Questa documento e' praprieta' di Tecnimant e non puo' essere

utilizzato in olcun modo do terzi senzo preventive outorizzozione


This document is tecnimont's property,and cannot be used
by others for ony purpose, without prior written consent
GENERAL EXCAVATION (m 3) (Code M02A)
LIMITED SECTION EXCAVATION (m 3) (Code M02B)
ELEVATED CONCRETE
CONCRETE
u
0
FOUNDATION
tO
I I
PTS I NGE
.,.._
..1::
.........
:a
I
I
I
I I I I
I I I I
l ol x l
LEAN CONCRETE
"' --"'
l!f!:'l
General excavation (Paving sub-bose)
-
Section excavation VEl =o1xb1xh1
...
.... ...
"'"'Z .., ...

l a2 x b2 l
I(
a x b
VGE=axbxh
VE2=o2xb2xh2 VE3=o3xb3xh3

Ill
=
C"..
..1::
I I
I I
I I
I I I I

I(
PSG
'\7
,.,.,
=
LEAN CONCRETE
0
< ..
F II
c n
m :a
, -
a


I
0
a

o<
"Til

mo

en"
cen
::tl
m

m
z
-i
"'D"'DI--1
==""

c.o
1
z: en o ...:..
9:0 0

N
m
"0
"
U!
"
0
c: c:
c:"

uc
"0 "'
c:
0 0
,:..c
-ea.
"- a.,
0 0
Ci.
_rn "i
Co;
0 Ul
.Ui
c:
() "
l!!a.
,.,
Ul c:
- 0
""
c
"0
"N
"0
N

0
"0
a.:;
c: 0
g


o e
E a.
c. 0
() N
" c: .... .,
Ul
i3 -
t:!
0"
;;-
co
0."0
0
0
"-u
0
" E
.B c:
c: "
"()
Eo
"
() c:
0 -
Uo
00
- N
Ul N
G>:.=
::J:,J
0:>
TM 930.1/04E
CIVIL WORKS
METHODS OF MEASUREMENT
41 F 62
CIVIL DEPT.
PTS/NGE
GENERAL EXCAVATION (m
3
)
(Code M02A)
r----,
I I
I I
I I
r-.....J L---,
I I
L---""'7'-----J
a x b
r--,
I I
I I
I I
I I
L------...J
OS
ANNEX 3
The excavation volume VE , is to be calculated as follows, regardless of the actual volume of the
excavation executed:
The volume of the concrete items and other obstacles ore not to be deducted from the V[.
Where:
"a" and "b" ore the dimensions shown in the drawings issued for construction and "h" is the
required excavation
CIVIL WORKS
METHODS OF MEASUREMENT
TM 930.1/04E
PAGE 42 dQ1F 62
Pagina
CIVIL DEPT.
DS
"
.0
0
c c
c "'
o::::
u c
"0 ;o
c
0 0
>.,'C
t"-

"-:o
0 0

fl) '3:
Cui
0"
g_
c
u :0
.!"-
>-
., c
- 0
-2.00m

c .s:::::.
"0
-4.00m

0
.,
:.C>.
>-.0

"'0

"

:0 0
a_:;
c 0
g
Q):g

0
E a_
co
UN
" c
>- " .,
:.0 -
t:'

"
co
O."Q
0
5..g
0
" E
Be
c :0
"' u
Eo
:0
u c
0 -
"B
0 0
N
U> N
Q):,.=

0:>
ANNEX 4
LIMITED SECTION EXCAVATION (m
3
) (Code AA02B)
DIRECT FOUNDATION WITH SUB-BASE IMPROVMENT
PTS/NGE/PSG
l l
ELEV. OF BOTTOM OF EXCAVATION
a x b
'r
The excavation volume of each individual foundation, is to be calculated as follows,
in according to pertinent codes, regardless of the actual volume of the excavation executed:
A = ax b
VE1=Axhl (Code up to 2.00m)
(Code from 2.01m to 4.00m)
V[3=Axh3 (Code above 4.00m)
where:
A= surface area of the bottom of foundation excavation according to the dimensions shown
in the drawings issued for construction
h= excavation depth between PTS/NGL/PSG and bottom of excavation elevation shown
in the drawings issued for construction
EXAMPLE: Foundation with dimensions 4.00mx3.00m and h= 4.50m
V 1 = ( 4.00x3.00)x2.00 = 24.00m
3
( with code up to 2.00m)
V 2 = ( 4.00x3.00)x2.00 = 24.00m
3
( with code from 2.01 m to 4.00m)
V 1 = (4.00x3.00)x0.50 = 6.0Qm3 ( with code about 4.00m)
c ~
" 0
E-
" .,
g Q;
-o:S
0
f/1
'E.>.
1--"
CIVIL WORKS
METHODS OF MEASUREMENT
TM 930.1 /04E
PAGE 43 Od.IF 62
Pagina
CIVIL DEPT.
DS
LIMITED SECTION EXCAVATION (Code AA028)
EXCAVATION FOR SINGLE FOUNDATION
.s:::.
BOTTOM ELEVATION OF LEAN CONCRETE
LEAN CONCRETE
a I b L
The excavation volume VE of each individual foundation, is to be calculated as follows,
regardless of the actual volume. of the excavation executed:
A = a X b
VE=Axh
D
a
A = Surface area of the foundation according to the dimensions shown in the drawings issued
for construction
h = Excavation depth between PTS/NGL/PSG and leon concrete bottom elevation shown in the
drawings issued for construction
.,
.0
0
c: c:
c:.,

u c:
"0 ;o
c:
0 0
>. c
-ea.
O.:J
0 0
0.:5
(I) 'i
:...._
c: .,
0"
g_
c:
0 :J
J!O.
>-
"c:
- 0
c:
., 0
E-
" "
0
0.,
.,.c.
0
" :C>-
f-.0
e
., 0

., 2

0
:J 0
a.:;
c: 0
g

c
0 I!'
E a.
co
0 N
., c:
f- .,
- "
"0 -
- t:'
0"

;: 0
O.-u
0

- 0
., E
.8 c:
c: :J
"0
Eo
:J
0 c:
0 -
"o
00
N

::3:.=;
0::>
......

......
CIVIL WORKS
METHODS OF MEASUREMENT
TM 930 .1/04E
PAGE 44 Od.,F 62
Pagina
CIVIL DEPT.
OS
ANNEX 6
EXCAVATION OF UNDERGROUND PIPING SYSTEM - SEWERS (m
3
) (Code AA02B)
"'
..r:::;
I
.F
I
..r:::;
Underground piping consist of all in-line materials as: pipes, fitting, valves, in-line instruments,
special parts, ecc.
0
1
-0
1
a -0
1
b =Elevation of ground (NGE/PTS)
-BOE
2
-BOE
3
=Eievation of bottom excavation according to the drawings issued for construction
DN =Nominal pipe diameter
-h
2
= Excavation height
I =Distance between two pipes of the bundles of pipes according to the construction drawings
K =Value (in em) to be added to the nominal diameter (DN) of pipes in order to evaluate
the excavation width, regardless of the actual execution
DN 35 em
DN :> 35 em to 60 em
DN :> 60 em to 150 em
DN :> 150 em
value of K = 35 em
value of K = 40 em
value of K = 45 em
value of K = 60 em
L
1
-L
2
etc.= Distance between two sections (A to Al - Al to A2 etc.) measured on the axis where
is changing the steady gradient of the ground
0
BOE
1
-BO
2
-BOE
3
"V
0000
K l ON l1 l ON l1 l ON l1 l ON lK
"' "' "' "' "' "' "' "'
Wl
The excavation volume V E is determined as follows:
V E= A x L + A
1
x L
1
etc.
Where:
A = W or w
1
x h
h = 0
1
- BOE
1
A
1
= W or w
1
x h
1
= 0
10
- BOE
2
etc.