You are on page 1of 15

INTRO PLEASE EDIT ONLY BLUE and LIGHT GREEN WITH BLUE TEXT CELLS NOT OTHER CELLS

THANKS! ENGR. LEANDRO B. PICZON II (leandrobpiczonii@hotmail.com) Professional Regulation Commission Number 0088397 Gandara, Samar, Philippines

Download as .xls file

Page 1

INTRO

Dedication Public License (DPL)

By downloading the spreadsheet, you confirm your agreement in this license.

I. Freeware First of all, the reasons why My Structural Analysis is free: I.a. Dedication My Structural Analysis is dedicated to the most wonderful people on earth :) Annabelle, Papa Leandro I and Mama Isabel (Deceased) My Structural Analysis is dedicated to the most wonderful place on earth :) Gandara, Samar, Philippines 6706 I.b. Binary What do you get if you buy software? Lots of ones and zeros, nothing more. If they were distributed as art, I could understand paying it. But if the main goal of their order is to earn money - by fees or ads - I don't like it! I.c. Conclusion This means that I grant you the license to use My Structural Analysis as much as you like. But if you like it, I ask two things of you: say a prayer for me (and the most wonderful girl and parents you're at it ;) ) to your god - or whatever you believe - and wish us some luck.

II. Limitations II.a. Reverse Engineering Reverse Engineering is not allowed as with nearly any software. If anyone has doubts in the honesty of the code, I will give insight to a trusted organization like a university under certain limitations (for example only one copy, for a limited time, and that has to be removed after the evaluation time has ended). II.b. Warranty I tried my very best to make the code of My Structural Analysis as stable as possible, and I give you the warranty that I placed no code to cause intentional harm to your system. However, adventuring sometimes involves cutting deep into the system sometimes, and I cannot guarantee that your system will be running the same as before. For example, tensional stress hosts may stop working. I can also give you no warranty that My Structural Analysis will calculate any structural forms, or that it will give you no false positives. For your own verification the location of the problem is shown with every entry, and if you have any questions remaining you can visit the support forum for more information. II.c. Liability Under no circumstances can you make me liable for any damage, however caused, including, but not limited to damage you might do to your system using My Structural analysis. II.d. Use of application in whole Free use is limited to the application in whole. Usage of parts only, for example the database or the plug-ins, is not permitted. II.e. Corporate use As companies are not individual persons and would have problems fullfilling the above terms, there is a license for corporate users that can be found at safer-networking.ie.

III. Distribution Here are some basic rules about distributing My Structural Analysis. III.a. Private distribution You may give away single copies of the software as long as you don't modify this license or other files of the archive. III.b. Mirroring If you want to mirror My Structural Analysis, feel free to do so as long as you don't modify the original archive. If you want to be kept up to date about major updates, you can subscribe to the mailing list. III.c. Publishing You may publish My Structural Analysis in a book or magazine (or other media) by simply sending a written request for permission, including a description of your specific needs. I request a copy of the media in which My Structural Analysis is published as compensation.

Page 2

Analysis

My Structural Analysis
Computing for LIVE LOAD Weight of Person + Environment Gravity Constant Weight in Newtons Number of Person/s per Square Meter Slab Self Weight Thickness CHB per SQ.M. Total Actual Load LL + Slab 60.00 9.81 588.60 0.59 1.50 75.00 3.23 50.00 0.49 5.01 kgs m/sec2 Newton (N) Kilonewton (KN) person/s millimeter KN/m2 kgs KN/m2 KN/m2

Earthquake

NSCP 2.2.5.2.1 (1992)

Design Base Shear Seismic Zone Factor Importance Factor Numerical Coeff Numerical Coeff

Status : (ON;OFF) (ZIC/Rw)W V=

V= Z= I= Rw=

ON 2.366 0.60 1.00 10.00 7.17 2.00 6.60 0.05 0.21 5.50

KN

C= 1.25(S)/T(2/3) Site Coeff Fundamental Period of Vibration Height T= Applied Weight Ct(hn)3/4

C= S= hn= Ct= T= W=

mts

KN

Computing Footing Reactions Bottom Reaction SLAB(WEIGHT)+Earthquake 7.37 KN

Page 3

SLAB
REINFORCED CONCRETE SLAB DESIGN SLAB 1 Edge 1 C = Continuous Ls 1300 mm Edge 4 Edge 2 D = Discontinuous EDGE CONDITIONS Edge 1 Edge 2 Edge 3 Edge 4 Edge 3 SHORT SPAN LENGTH OF SLAB SPAN Steel Yield Strength Concrete Compressive Strength Concrete Cover ASSUMED SLAB THICKNESS Minimum Thickness Maximum Thickness Smax=2t Concrete Density LOADS Selfweight Dead Load Live Load Actual Load SHORT SPAN s Actual Moment kN-m BAR SIZE mm assumed spacing along mm layer 1 or 2 effective depth mm Act. Steel Ratio Minimum Steel Ratio -0.262 -2.44 12 300 B1 49.00 0.0077 0.0051 0.0378 0.0284 0.0077 4.11 SAFE LONG SPAN 0.056 0.52 12 300 B2 37.00 0.0102 0.0051 0.0378 0.0284 0.0102 4.11 SAFE kN/m2 kN/m
2

D D D D LONG SPAN 5000

Ll 5000 mm

mm 1 WAY MPA MPA mm mm OK OK mm mm mm kN/m3

1300 0.26 275 21 20 75.0 70.0 139.0 150 23.5 3.23 0.49 1.78 5.50 EDGE 2 0.000 0.00 12 300 T1 49.00 0.0077 0.0051 0.0378 0.0284 0.0077 4.11 SAFE

kN/m2 kN/m2 EDGE 1 0.000 0.00 12 300 T2 37.00 0.0102 0.0051 0.0378 0.0284 0.0102 4.11 SAFE

per M length EDGE 3 0.000 0.00 12 300 T2 37.00 0.0102 0.0051 0.0378 0.0284 0.0102 4.11 SAFE EDGE 4 0.000 0.00 12 300 T1 49.00 0.0077 0.0051 0.0378 0.0284 0.0077 4.11 SAFE

bal
Max. Steel Ratio Adapted Steel Ratio Resulting Moment kN-m Remarks

Page 4

SLAB

development length

270.04

135.74

Page 5

SLAB

Ly/Lx = 0.2600

Nd = 4

g=

-1.0496

10

147.06 1442.65 1.44 SHORT LONG 1000

kgs/sq.m. kgs/sqm Nm2 KN/m2 0.85 0 0 per meter length used in design

0.850 0.9 SHORT 113.10 LONG 113.10 EDGE 1 113.10 EDGE 2 113.10 EDGE 3 113.10 EDGE 4 113.10

Factor

1 based on 10.2.7.3
SHORT

strength reduction factor Area of One Bar Area of One Bar Area of One Bar Area of One Bar Area of One Bar Area of One Bar 376.99 LONG 376.99 EDGE 1 376.99 EDGE 2 376.99 EDGE 3 376.99 EDGE 4 376.99 Total Area Bars Total Area Bars Total Area Bars Total Area Bars Total Area Bars Total Area Bars

Page 6

SLAB
SHORT LONG SHORT LONG SHORT LONG 4.33 pcs 16.67 pcs 4.24 kgs 4.24 kgs 0.08 KN 0.08 KN

Page 7

SLAB

SHORT 3.33 LONG 3.33 EDGE 1 3.33 EDGE 2 3.33 EDGE 3 3.33 EDGE 4 3.33 no of bars per meter no of bars per meter no of bars per meter no of bars per meter no of bars per meter no of bars per meter

Page 8

SLAB

Page 9

FOOTING
RC ISOLATED COLUMN FOOTING Corner Footing

Edge 1

L X

Summary Results Pu Dimension


Footing Dimension Assumed Thickness Assumed Depth Soil Pressure L W t d 650 1300 200.00 114.00 8.73 150.0 mm mm mm mm KN/m2 KN/m2

7.37

kN

Allowable Soil Pressure


Strength Reduction Factor Bar Yield Strength Concrete Compressive Strength Concrete Cover

ok
0.70 275 21.0 70.0 1300 300 650.00 -1.53 0.00 mm mm MPA MPA mm mm mm mm

Column Details
Column Dimension along Length Column Dimension along Width Column Distance from Edge1

Depth required for One-Way Shear Depth required for Punching Shear

use d

114.00

Design Moment

2.40 1.23E-03 0.0378 0.0284 0.0051 0.0051 16 201.06 754.47 3.75

KN-m

Reinforcement Details
Actual Steel Ratio Balanced Steel Ratio Maximum Steel Ratio Minimum Steel Ratio Adapted Steel Ratio Bar Size to be used Bar Area Steel Area No. of Bars to be used

mm mm2 mm2 pcs

Page 10

FOOTING
Adapted No. of Bars distributed both ways spacing 4 123.5 pcs mm Engr. Leandro B. Piczon II

Page 11

FOOTING

0.9 pure flexure 0.75 flexure and axial 0.7 other members

A reqd A used Area tmin SHEAR BAR TO USE no. of bars steel ratio depth used allow depth spacing min depth location location say 200 use 450 114.0 123.5 8.73 78.73 0.00 16 4

0.04 0.85 OK OK OK pcs bothways OK OK OK SHEAR OK ERROR MAX 7.37 M1 X M2 Mt MOMENT 0 MAX 1357 1357 357 357 3 484449 3071 2.47 -114 886.00 QUADRATIC MIN 2.40 2.40 0 0 2.40 2.40 0.00 0.00 #DIV/0! 2.4 0 -2.397 1.300 4.793 2.397 0.00 0.000 #DIV/0! #DIV/0! #DIV/0! 7.37 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 0.00 0.00 7.37 TOTAL 650.00 MIN 0 L1 -650.00 7.374 7.37 QU L2 1300.00 0.000 0 -11.34 L3 0.00 0.000 0 2217

if Col location from edge1 is less than 325

-0.65 Vu ONE WAY 3.146 Vu TWO WAY 0.9 pure flexure 0.75 flexure and axial 0.7 other members

Page 12

FOOTING
A 88963793.10 0.02 q B -150786090.00 C 2396596.88

Page 13

FOOTING

Page 14

FOOTING

Page 15

You might also like