You are on page 1of 517

MILITARY ENGINEER SERVICES

STANDARD SCHEDULE OF RATES

2010
PART II - RATES

COMPILED UNDER THE ORDERS OF


LIEUTENANT GENERAL AK NANDA AVSM
ENGINEER-IN-CHIEF

All rights reserved. No part of this publication, either in English or in Hindi, may be reproduced in
any form or by any means, electronic or mechanical, including photocopy, recording or any information
storage and retrieval system, without permission, in writing, from the Directorate of Contract
Management, Military Engineer Services, New Delhi. Photocopying of this book is strictly prohibited
A GOVERNMENT OF INDIA PUBLICATION
Published by
DIRECTORATE OF CONTRACT MANAGEMENT
Military Engineer Services, NEW DELHI-110 011
&
Printed & Marketed by
JAIN BOOK AGENCY
Authorised Dealers of Govt. Publications
C-9, Connaught Place, New Delhi-110001
Phones : 23416390 upto 97, 41513852
E-mail : sales@jainbookagency.com
Website : www.jainbookagency.com
Distributed by
JBA DISTRIBUTORS
N-67, First Floor, Munshiram Building,
Connaught Place, New Delhi-110001
Phone : 41523870, 23354824 Fax : 41513850
E-mail : sales@jba.in
Website : www.jba.in
JAIN BOOK AGENCY (SOUTHEND)
1, Aurobindo Place Market,
Hauz Khas, New Delhi-110016
Phone : 26567066, 26566113,41758700
E-mail : sales@jainbookagency.com
Website : www.jainbookagency.com
JAIN BOOK AGENCY (CENTRAL)
5061/1, Sant Nagar, Karol Bagh,
New Delhi - 110005
Phone : 47528979

JAIN BOOK AGENCY (GURGAON)


12, Central Plaza Mall, Sector 53,
Golf Course Road,
Gurgaon 122002 Haryana
Phone : 4143020,
Mobile 9810666810
JAIN BOOK AGENCY (GREATER NOIDA)
11 Jagat farm Complex
Gama Sector Market
Near OBC Bank
Greater Noida
Mobile 9891149148

DIAL-A-BOOK
011-4175 8700

Books will be delivered next day by COURIER


(Payment to courier-boy)
in Delhi, Noida, Ghaziabad, Faridabad & Gurgaon
(nominal courier charges extra)
Also available at
All Leading Booksellers & Authorised Govt. Dealers In India
Price : Rs. 625/- (excluding postage and forwarding charges etc.)

FOREWORD

1. This Standard Schedule of Rates Part II 2010 replaces Standard Schedule of Rates 2004
(Part II). It is a very important document, which is used not only in MES but also referred to by
a large number of Departments.
2. Besides updating the existing rates six new chapters pertaining to utility services have
been added, in conformity with SSR Part I (2009), to make the SSR comprehensive and
exhaustive.
3. This publication is in user friendly format and will be very useful to all those associated
with preparation of estimates, making of contract documents, execution of works and payment
of bills. I am sanguine, it will guide all executives and staff in achieving improved standards of
working.

Station : New Delhi- 11


Dated : 04 Jun 2010

(AK Nanda)
Lt Gen
Engineer-in-Chief

PREFACE

1. The Standard Schedule of Rates - Part II Rates, (SSR Part- II) was last revised in 2004.
SSR Part II is applicable to all MES formations spread across the length and breadth of the
Country. Task for revision was initiated during Aug 2008 and services of a number of
experienced Officers have been utilized for its compilation who have endeavoured to put in
their best both in terms of efforts and skills. The colossal task involved did not only pertain to
updating the existing rates, but also to incorporate the provisions contained in SSR Part I (2009),
which have come into effect from 15 Sep 2009. The work has been completed and publication
is being issued as SSR Part II, 2010.
2. The documents would be useful to the engineers fraternity, which is associated with
preparation of estimates, making of contracts, execution of works and financial closure. Despite
taking adequate care in preparation of this treatise, some errors may have crept in. In case any
omission(s) is noticed, it may be brought to the notice of Joint Director General (Contracts),
Military Engineer Services, Engineer-in-Chief's Branch, Integrated HQ of Ministry of Defence
(Army), Kashmir House, Rajaji Marg, New Delhi - 110011 for correction/updation.
3. We would welcome suggestions for improvement and modification.

Station : New Delhi- 11


Dated : 04 Jun 2010

(Brajesh Kumar)
Maj Gen
Director General of Works

CONTENTS

CONTENTS
Page No.
SECTION 1 : GENERAL RULES .................................................................................................. 1-15
SECTION 2 : LABOUR RATE ..................................................................................................... 16-17
SECTION 3 : EARTH WORK ...................................................................................................... 18-33
Special conditions ................................................................................................................................... 18
Surface excavation ................................................................................................................................. 23
Rough excavation, excavation over areas, in trenches, etc. ........................................................... 23
Surface dressing ...................................................................................................................................... 25
Timbering to excavations ...................................................................................................................... 25
Spreading, levelling and ramming in floors, etc. .............................................................................. 26
Forming embankments and traverses ................................................................................................. 26
Bore holes for under-reamed piles and bored case in situ piles .................................................... 27
Removal of spoil ...................................................................................................................................... 28
Cutting down trees ................................................................................................................................. 29
Hand packing, filling and hardcore .................................................................................................... 30
Shingle/moorum filling in floors, etc. ................................................................................................ 31
Anti-termite treatment (pre & post construction) ............................................................................ 32
Materials (supplied only) ....................................................................................................................... 33
SECTION 4 : CONCRETE ............................................................................................................ 34-53
Special conditions ................................................................................................................................... 34
Lime concrete in foundations ............................................................................................................... 36
Mixed cement concrete delivered on bunker .................................................................................... 37
Cement concrete in foundations, surface drains, walls, mass concrete, retaining
walls, etc. ............................................................................................................................................ 38
Precast cement concrete work .............................................................................................................. 39
Precast hollow concrete blocks ............................................................................................................ 40
Reinforced cement concrete work (nominal mix) ............................................................................ 43
Reinforced cement concrete work(design mix) ................................................................................ 45
Cast-in-situ bored piles .......................................................................................................................... 46
Precast reinforced cement concrete ..................................................................................................... 47
Posts, fencing posts, door and window frames ......................................................................... 47
Miscellaneous items ......................................................................................................................... 48
Cutting into or through concrete ......................................................................................................... 49
Toothing and bonding ........................................................................................................................... 51
Polyester triangular fibres as secondary reinforcement in concretes and mortars ................... 51
Materials (supplied only) ....................................................................................................................... 52
SECTION 5 : BRICK WORK ....................................................................................................... 54-75
Special conditions ................................................................................................................................... 54
Brickwork in burnt bricks ..................................................................................................................... 57
Brickwork in burnt clay fly ash bricks ................................................................................................ 60
Extras on brick work .............................................................................................................................. 62
Brick work around steel joists, stanchions etc. ................................................................................. 63
Cavity wall ............................................................................................................................................... 63
Brick window cills, cornices, etc. ......................................................................................................... 63
Fair cutting on brickwork (any description) ..................................................................................... 64
Damp proof courses ............................................................................................................................... 64

II

CONTENTS

Cutting and pinning in existing work ................................................................................................ 65


Cutting holes for bolts, pipes, joists, air flues, ventilators, cast iron boxes etc., and
making good to existing work ....................................................................................................... 65
Cutting openings for doors, windows, etc. and making good ...................................................... 67
Fixing holdfasts in jambs of existing opening and making good .................................................. 68
Cutting and facing walls, etc. .............................................................................................................. 69
Filleting ...................................................................................................................................................... 71
Bedding and pointing frames in exiting openings ........................................................................... 71
Fixing only gratings, soot doors, etc. in existing work .................................................................... 71
Firebrick work ......................................................................................................................................... 72
Acid resisting brickwork ....................................................................................................................... 72
Sweeping chimney flues ........................................................................................................................ 72
Brick edgings ............................................................................................................................................ 73
Brickwork in burnt clay sewer bricks ................................................................................................. 73
Materials (supplied only) ....................................................................................................................... 74
SECTION 6 : STONE MASONRY ........................................................................................... 76-100
Special conditions ................................................................................................................................... 76
Stone walling ........................................................................................................................................... 80
Facing to stone walling .......................................................................................................................... 82
Stone walling, jodhpur type ................................................................................................................. 84
Facing to stone walling jodhpur type ................................................................................................. 84
External angles (quoins and jambs) .................................................................................................... 85
Arches ....................................................................................................................................................... 85
Boulder work ........................................................................................................................................... 86
Cutting opening for doors, windows, etc. and making good ........................................................ 86
Cutting chases, rebates etc. in existing walls .................................................................................... 87
Cutting and forming toothing to stone walls .................................................................................... 87
Preparing uncoursed stone walls for concrete band courses, brick courses, bond courses
of masonry in richer mix, etc. ........................................................................................................ 88
Dressed stone work ................................................................................................................................ 88
Dressed stone slabs in copings, window cills, etc. ........................................................................... 90
Dressed stone slabs in shelves, chajjas, etc. ....................................................................................... 90
Jodhpur stone lintels and beams .......................................................................................................... 91
Stone chowkats for doors, windows, etc. .......................................................................................... 91
Jodhpur stone slab roofing .................................................................................................................... 91
Mortices ..................................................................................................................................................... 92
Labours on dressed stone ...................................................................................................................... 92
Mescellaneous labours ........................................................................................................................... 94
Stone kerbs ............................................................................................................................................... 94
Veneering to walls, fireplaces, pillars, steps etc. .............................................................................. 95
Dholpur stone cladding ......................................................................................................................... 96
Marble work ............................................................................................................................................. 97
Granite work ............................................................................................................................................ 98
Materials (supplied only) ....................................................................................................................... 99
Building stone, etc. ........................................................................................................................... 99
Boulders (quarried or river bed) .................................................................................................... 99
Stone for dressed stone work ....................................................................................................... 100
SECTION 7 : WOODWORK (CARPENTERS WORK) ................................................... 101-123
Special conditions ................................................................................................................................. 101
Shoring and strutting ........................................................................................................................... 103

CONTENTS

III

Centering to arches .............................................................................................................................. 103


Formwork to concrete etc. .................................................................................................................. 103
Timber in scantlings ............................................................................................................................. 107
Fillet work ............................................................................................................................................... 109
Battens for tiles, etc. .............................................................................................................................. 110
Trellis work (Jafri) ................................................................................................................................. 110
Boarding in roofs, ceilings, partitions, fascia, barge, soffit, etc. (Except flooring and
skirting) ............................................................................................................................................. 111
Weather boarding ................................................................................................................................. 113
Boarded floors and skirtings ............................................................................................................... 114
Piling ........................................................................................................................................................ 116
Pile driving ............................................................................................................................................. 117
Plugging to walls, etc. .......................................................................................................................... 117
Repair to timber roof trusses etc. ....................................................................................................... 118
Workmanship labour only .................................................................................................................. 118
Planning surfaces ........................................................................................................................... 119
Beads, grooves, chamfers, mouldings, etc. ................................................................................ 119
Drilling holes ................................................................................................................................... 120
Ballies ................................................................................................................................................ 121
Materials (supplied only) ..................................................................................................................... 121
Boards or planks ................................................................................................................................... 122
Nails, tacks and screws ........................................................................................................................ 122
Wood screws .......................................................................................................................................... 123
SECTION 8 : JOINERY ............................................................................................................. 124-163
Special conditions ................................................................................................................................. 124
Door and window chowkats and other frames ............................................................................. 125
Shutters ................................................................................................................................................... 126
Glazed and skeleton shutters ............................................................................................................. 128
Panelled shutters ................................................................................................................................... 129
Factory made shutters ......................................................................................................................... 130
Flush shutters ........................................................................................................................................ 130
Louvred shutters ................................................................................................................................... 131
Louvred frames ..................................................................................................................................... 132
Moulding ................................................................................................................................................ 132
Turners work ........................................................................................................................................ 132
Treads and risers ................................................................................................................................... 134
Housed strings ....................................................................................................................................... 135
Handrails ................................................................................................................................................ 135
Newel posts, balusters, etc. ................................................................................................................. 136
Balusters .................................................................................................................................................. 137
Miscellaneous ........................................................................................................................................ 138
Jobbing work generally ........................................................................................................................ 139
Repairs to chowkhats or frames ........................................................................................................ 140
Repairs to shutters ................................................................................................................................ 141
Miscellaneous repairs ........................................................................................................................... 141
Solid PVC joinery .................................................................................................................................. 142
Factory made solid PVC panel, glazed, wire gauged, louvre door shutters ............................ 147
Factory made PVC solid PVC door frame (chowkhat) ................................................................. 149
Factory made solid PVC moulded door shutters .......................................................................... 149
Factory made PVC moulded door shutter ....................................................................................... 150

IV

CONTENTS

PVC sheet cladding material .............................................................................................................. 150


Solid PVC wall lining ........................................................................................................................... 151
Insulated PVC wall lining ................................................................................................................... 151
Solid PVC sandwich panel for partitions ........................................................................................ 152
Feathered edges PVC sheet in strips & channel for solid PVC wall lining, solid PVC
partitions .......................................................................................................................................... 152
Solid PVC insulation panel for false ceiling .................................................................................... 153
PVC partition ......................................................................................................................................... 153
Solid PVC frame .................................................................................................................................... 154
Product Drawings ................................................................................................................................ 156
SECTION 9 : BUILDERS HARDWARE .............................................................................. 164-184
Special conditions ................................................................................................................................. 164
Bolts ......................................................................................................................................................... 166
Sliding door bolt with hasp and staple, suitable for use with padlock ..................................... 168
Hinges ...................................................................................................................................................... 169
Spring for doors .................................................................................................................................... 172
Handles ................................................................................................................................................... 173
Latches .................................................................................................................................................... 173
Locks ........................................................................................................................................................ 174
Fasteners and stays ............................................................................................................................... 175
Drawer pulls and handles .................................................................................................................. 176
Hat pegs and hooks .............................................................................................................................. 177
Gate and shutter, hooks and eyes ...................................................................................................... 177
Knobs ....................................................................................................................................................... 178
Hasps and staples ................................................................................................................................. 178
Curtain rails ........................................................................................................................................... 179
Finger plates ........................................................................................................................................... 179
Kicking plates ........................................................................................................................................ 180
Towel rails .............................................................................................................................................. 180
Floor door stoppers and door catches .............................................................................................. 181
Door closer ............................................................................................................................................. 181
Wire cloth and wire netting ................................................................................................................ 182
Wire netting ........................................................................................................................................... 183
Stainless steel wire netting .................................................................................................................. 183
Aluminium alloy/stainless steel wire cloth ..................................................................................... 183
Floor spring ............................................................................................................................................ 184
Materials (supplied only) ..................................................................................................................... 184
Wire netting ..................................................................................................................................... 184
Wire cloth ......................................................................................................................................... 184
SECTION 10 : STEEL, ALUMINIUM AND IRON WORK ............................................ 185-210
Special conditions ................................................................................................................................. 185
Cast iron work ....................................................................................................................................... 188
Mild steel works (miscellaneous) ....................................................................................................... 188
Screw bolts and nuts etc. ..................................................................................................................... 191
Steel sheet flue pipes ............................................................................................................................ 192
Mild steel sheeting, plain & corrugated ........................................................................................... 193
Raking cutting, etc. on steel sheet work ........................................................................................... 195
Steel reinforcement for concrete ........................................................................................................ 195
Hard drawn steel wire fabric in reinforcement .............................................................................. 195

CONTENTS

Structural steel work ............................................................................................................................ 196


Expanded metal and welded steel wire fabric in partitions, etc. ................................................ 198
Wire mattresses and shaped nets ...................................................................................................... 198
Chain link fencing ................................................................................................................................ 199
Wire fencing, etc. .................................................................................................................................. 199
Collapsible steel gates ........................................................................................................................... 200
Steel rolling shutters ............................................................................................................................. 200
Steel doors, windows and ventilators .............................................................................................. 201
Pressed steel door frames .................................................................................................................... 203
Welding in repairs ................................................................................................................................ 203
Anodised aluminium frames for doors, windows and ventilators ............................................. 204
Anodised aluminium shutters for doors, windows and ventilators .......................................... 204
Anodised aluminium frame work (sanp grid) for false ceiling ................................................... 205
Labour only on iron and steel work .................................................................................................. 207
Cutting or notching on iron and steel work ............................................................................. 208
Repairs to grates, ranges, etc. ...................................................................................................... 208
Materials (supplied only) ..................................................................................................................... 209
SECTION 11 : ROOF COVERING ........................................................................................ 211-235
Special conditions ................................................................................................................................. 211
Plain or corrugated steel or asbestos cement sheeting in roofs, chajjas, sunshades,
cloaking to walls and partitions, covering to doors, etc. ....................................................... 212
Corrugated steel sheeting .................................................................................................................... 213
Corrugated aluminium sheeting ........................................................................................................ 214
Corrugated translucent sheeting ....................................................................................................... 214
Plain steel sheeting ............................................................................................................................... 214
Plain, aluminium sheeting .................................................................................................................. 216
Asbestos cement sheeting-grey .......................................................................................................... 217
R.M.P. sheeting ..................................................................................................................................... 217
Asbestos cement accessories-grey ...................................................................................................... 218
Extra to corrugated mildsteel sheeting, aluminium corrugated Sheeting and asbestos
cement corrugated or semi-corrugated Sheeting (any description or thickness) .............. 219
Extra labour on steel, aluminium and asbestos cement sheeting ................................................ 221
Roofing tilesmangalore pattern ...................................................................................................... 221
Mud phuska ........................................................................................................................................... 222
Brick tile terracing ................................................................................................................................. 223
Stone slab roofing ................................................................................................................................. 224
Repairs and waterproofing treatment to terraced roofs ............................................................... 224
Bitumen felt waterproofing treatment ............................................................................................. 225
Shingle roofing ...................................................................................................................................... 226
Matting, thatch, bamboo work, etc. .................................................................................................. 226
Matting .................................................................................................................................................... 226
Thatching ................................................................................................................................................ 227
Bamboo work (straight or diagonal, in any position) ................................................................... 228
HP burnt clay tile terracing ................................................................................................................ 229
Eaves gutters and rainwater pipes generally .................................................................................. 229
Eaves gutterssteel sheet ................................................................................................................... 230
Rain water pipescast iron ............................................................................................................... 231
Guttersasbestos cement ................................................................................................................... 232
Rainwater pipesasbestos cement ................................................................................................... 232
Cutting pipes and gutters ................................................................................................................... 233

VI

CONTENTS

Taking down, eaves gutters and rainwater pipes .......................................................................... 233


Materials (supplied only) ..................................................................................................................... 233
Asbestos cement roofing sheets and accessories ...................................................................... 233
Roofing tiles ..................................................................................................................................... 235
Roofing slabs ................................................................................................................................... 235
Bitumastic products ....................................................................................................................... 235
SECTION 12 : CEILING AND LININGS ............................................................................ 236-252
Special conditions ................................................................................................................................. 236
Asbestos cement building boards ...................................................................................................... 237
Insulation boards .................................................................................................................................. 237
Medium density fibre board ............................................................................................................... 239
High pressure steam cured (HPSC) non-asbestos fibre cement reinforced multipurpose
board ................................................................................................................................................. 240
Decorative laminates ............................................................................................................................ 241
Bonded mineral wool slabs/blanket ................................................................................................. 241
Plywood .................................................................................................................................................. 242
Particle boards ....................................................................................................................................... 242
Prelaminated particle boards ............................................................................................................. 243
Block boards and veneered particle boards ..................................................................................... 244
Circular cutting to boards, etc. .......................................................................................................... 246
Cutting holes .......................................................................................................................................... 246
Textile surfaces ...................................................................................................................................... 247
Reed walling .......................................................................................................................................... 247
Plaster of paris ceiling .......................................................................................................................... 248
Materials (supplied only) ..................................................................................................................... 249
Plywood ........................................................................................................................................... 250
Particle boards ................................................................................................................................ 250
Block boards and veneered particle boards .............................................................................. 251
Bonded mineral wool blanket/slab ............................................................................................ 252
Textiles .............................................................................................................................................. 252
Prelaminated boards ...................................................................................................................... 252
SECTION 13 : FLOOR FINISHES AND PAVINGS ......................................................... 253-282
Special conditions ................................................................................................................................. 253
Stone slab floors .................................................................................................................................... 254
Stone sett flooring ................................................................................................................................. 256
Kota stone flooring ............................................................................................................................... 256
Dry stone floors ..................................................................................................................................... 257
Marble slab tile flooring ....................................................................................................................... 257
Granite tile flooring .............................................................................................................................. 259
Cudappah stone slab over cooking platform .................................................................................. 259
Precast concrete slab floors ................................................................................................................. 260
Lime concrete sub-floors or bases ...................................................................................................... 260
Cement concrete in sub-floors, sub-bases, floors and pavings, etc. ............................................ 261
Wearproof topping ............................................................................................................................... 263
Terrazzo cast in - situ ........................................................................................................................... 264
Brick floors .............................................................................................................................................. 266
Floor And Wall Tiling .......................................................................................................................... 268
Cement Concrete And Terrazzo Tiles .............................................................................................. 272
Acid Resistant Tiles .............................................................................................................................. 273

CONTENTS

VII

Repairs To Floor And Wall Tiling ...................................................................................................... 274


Damp Proof Courses ............................................................................................................................ 275
Linoleum Covering To Floors Etc. ..................................................................................................... 276
Rubber Sheet And Tile Flooring ......................................................................................................... 276
PVC Sheet And Tile Flooring ............................................................................................................. 277
Materials (Supplied Only) ................................................................................................................... 278
SECTION 14 : PLASTERING AND POINTING ............................................................... 283-295
Special conditions ................................................................................................................................. 283
Cement, cement lime and lime plaster work .................................................................................. 287
Special finishes ...................................................................................................................................... 288
Miscellaneous ........................................................................................................................................ 289
Forming letters, etc. .............................................................................................................................. 290
Mud plastering and leeping ................................................................................................................ 290
Taking down plastering on lathing ................................................................................................... 291
Preparing old walls (to receive plaster, etc.) ................................................................................... 291
Dubbing on old walls ........................................................................................................................... 292
Metal lathing .......................................................................................................................................... 292
Pointing generally ................................................................................................................................. 292
Raking out joints (in old work) .......................................................................................................... 293
Pointing ................................................................................................................................................... 294
Materials (supplied only) ..................................................................................................................... 295
SECTION 15 : WHITE WASHING, COLOUR WASHING AND DISTEMPERING 296-299
Special condition ................................................................................................................................... 296
Preparatory work ................................................................................................................................. 297
White washing & colour washing ..................................................................................................... 298
Priming surfaces .................................................................................................................................... 298
Distempering, cement painting, etc. ................................................................................................. 299
Miscellaneous ........................................................................................................................................ 299
Materials (supplied only) ..................................................................................................................... 299
SECTION 16 : GLAZING ......................................................................................................... 300-306
Special conditions ................................................................................................................................. 300
Sheet glass .............................................................................................................................................. 301
Figured glass .......................................................................................................................................... 301
Wired class and wired figured glass ................................................................................................. 302
Heat absorbing glass & reflective solar control film ...................................................................... 302
Miscellaneous ........................................................................................................................................ 303
Glazing in repairs ................................................................................................................................. 303
Labours on glass .................................................................................................................................... 304
Materials (supplied only) ..................................................................................................................... 305
SECTION 17 : PAINTING ....................................................................................................... 307-322
Special conditions ................................................................................................................................. 307
Painting wood and wood based surfaces ........................................................................................ 311
Cresoting, oiling, etc. ............................................................................................................................ 312
Clear finishes to wood and wood based surface ............................................................................ 313
Staining and varnishing ...................................................................................................................... 313
Polishing ................................................................................................................................................. 314
Painting brick, stone, concrete, asbestos cement or plaster surfaces .......................................... 314

VIII

CONTENTS

Painting steel and iron surfaces ......................................................................................................... 316


Special painting ..................................................................................................................................... 318
Writing .................................................................................................................................................... 319
Miscellaneous work .............................................................................................................................. 320
Line painting on roads, etc. ................................................................................................................ 320
Materials (supplied only) ..................................................................................................................... 321
SECTION 18 : WATER SUPPLY, PLUMBING, DRAINS AND SANITARY
APPLIANCES .................................................................................................. 323-374
Special conditions ................................................................................................................................. 323
Cast iron water mains ......................................................................................................................... 323
Cast iron fittings for pressure pipe for water, gas and sewage ................................................... 325
Joints for water mains .......................................................................................................................... 326
Cutting, taking up, etc. of water mains ........................................................................................... 327
Sluice valves, hydrants, etc. (Supplied by M.D.) ............................................................................ 329
Water meters (supplied by M.D.) ...................................................................................................... 330
Drilling and tapping water mains ..................................................................................................... 331
Steel water tubing ................................................................................................................................. 331
Repairs, alterations, etc., to water pipes and connections ........................................................... 333
Polyethylene and unplasticised PVC pipes .................................................................................... 334
Water tanks (supplied by M.D.) ......................................................................................................... 338
PVC water tanks ................................................................................................................................... 339
Lagging and wrapping on pipes with bonded mineral wool pre-formed pipe sections ....... 339
Plumbing generally ............................................................................................................................... 340
Polytetra methylene terephthalate (PTMT) engineering thermoplastic bath fitting ............... 345
Soil, waste and vent pipes ................................................................................................................... 349
Cast iron soil, waste and vent pipes ................................................................................................. 350
Fittings for cast iron pipes ................................................................................................................... 350
AC soil, waste and vent pipes ............................................................................................................ 352
PVC soil, waste and rainwater (SWR) drainage pipes ................................................................. 353
Fittings for PVC (SWR) pipes ............................................................................................................. 353
Connectors ............................................................................................................................................. 354
Joints ........................................................................................................................................................ 355
Traps for basins and sinks ................................................................................................................... 355
Floor and nahani traps ........................................................................................................................ 356
Gully traps .............................................................................................................................................. 356
Concrete foundation beds, etc. to drain pipes ................................................................................ 356
Salt-glazed stoneware drain pipes .................................................................................................... 358
Reinforced concrete drain pipes ........................................................................................................ 359
Salt-glazed stoneware gully traps ..................................................................................................... 360
Intercepting traps ................................................................................................................................. 360
Testing drains, etc. ................................................................................................................................ 360
Alterations, additions, etc. to existing drainage ............................................................................. 361
Setting only cast iron manhole covers and frames (supplied by M.D) ...................................... 362
Water closets .......................................................................................................................................... 363
Urinals ..................................................................................................................................................... 365
Wash basins ........................................................................................................................................... 366
Shower bath fittings ............................................................................................................................. 366
Making good decorations .................................................................................................................... 368
Galvanised steel water tubing ............................................................................................................ 368
Materials (supplied only) ..................................................................................................................... 368
Miscellaneous ........................................................................................................................................ 369

CONTENTS

IX

SECTION 19 : ELECTRICAL WORK .................................................................................... 375-432


Electrical poles and struts ................................................................................................................... 375
Wood poles ............................................................................................................................................. 375
Pre-stressed concrete poles .................................................................................................................. 376
Steel tubular poles ................................................................................................................................. 376
Cross arms .............................................................................................................................................. 377
Insulators ................................................................................................................................................ 377
Air circuit breaker (ACB) .................................................................................................................... 379
Automatic power factor correction (APFC) panel ........................................................................ 380
Automatic voltage stabilizer (servo controlled) .............................................................................. 381
Vacuum circuit breaker (VCB) ........................................................................................................... 381
SF6 circuit breaker ................................................................................................................................ 382
Stay assembly ........................................................................................................................................ 384
Overhead conductors ........................................................................................................................... 384
Line connectors ..................................................................................................................................... 385
Line taps ................................................................................................................................................. 385
Guarding ................................................................................................................................................. 386
Danger boards ....................................................................................................................................... 386
Aerial fuses ............................................................................................................................................. 387
Expulsion fuses ...................................................................................................................................... 387
Switches air break, gang operated .................................................................................................... 387
Air-break (switch) isolators ................................................................................................................ 388
Arresters lightning low tension .......................................................................................................... 388
Arresters lightning high tension ........................................................................................................ 389
Transformers .......................................................................................................................................... 389
House service brackets ......................................................................................................................... 391
Service connections .............................................................................................................................. 392
Cable termination 11 KV HT (cold shrinkable) .............................................................................. 394
Cable termination 11 KV HT (heat shrinkable) .............................................................................. 395
Precast concrete cable covers ............................................................................................................. 396
PVC underground cable ...................................................................................................................... 397
Street light fittings ................................................................................................................................. 398
Synthetic insulating mat ...................................................................................................................... 399
High mast light ...................................................................................................................................... 400
Dismantling ............................................................................................................................................ 400
Point wiring ........................................................................................................................................... 402
Cast iron/pressed steel terminal boxes ............................................................................................ 408
Pendants ................................................................................................................................................. 408
Fluorescent tuble light fittings/CFL fittings/ flame proof fitting ................................................ 409
Light fittings ........................................................................................................................................... 415
Switches .................................................................................................................................................. 418
Flame proof switches & switch socket combinations .................................................................... 418
Miniature circuit breaker (M.C.C.BS.) .............................................................................................. 419
Sheet metal enclosures with socket plug top and MCBS .............................................................. 420
Sheet metal enclosures for DB's when MCBS to be used .............................................................. 420
Lighting conductors ............................................................................................................................. 421
PVC/ polycarbonate ............................................................................................................................ 422
PVC rectangular block ......................................................................................................................... 422
Miscellaneous ........................................................................................................................................ 422
Earthing .................................................................................................................................................. 422

CONTENTS

Electric meters (supplied by M.D.) .................................................................................................... 425


Fan work ................................................................................................................................................. 426
Fan regulator and dimmer .................................................................................................................. 426
Wiring ...................................................................................................................................................... 426
Rigid non-metallic PVC conduits ...................................................................................................... 429
Moulded case circuit breaker (MCCB) ............................................................................................. 429
Materials (supplied only) ..................................................................................................................... 430
SECTION 20A : ROAD WORK .............................................................................................. 432-444
Special conditions ................................................................................................................................. 433
Formation, sub-grade, berms, etc. ..................................................................................................... 433
Soling (sub-base) ................................................................................................................................... 434
Granular sub bases & light wearing surfaces ................................................................................. 434
Water bound macadam (WBM) sub base & base courses ............................................................ 435
Preparation of surfaces prior to application of primer ................................................................. 436
Priming surfaces .................................................................................................................................... 436
Bituminous surface dressing ............................................................................................................... 436
Unsurfaced surfaces of WBM ............................................................................................................. 437
Bituminous carpet ................................................................................................................................. 438
Seal coats ................................................................................................................................................ 438
Rolling ..................................................................................................................................................... 438
Screening road metal, etc. ................................................................................................................... 440
Breaking stone, boulder, etc. ............................................................................................................... 440
Repairs to surfaces of macadam road .............................................................................................. 441
Materials (supplied only) ..................................................................................................................... 443
Broken stones and chipping for bitumen work .............................................................................. 444
SECTION 20B : ROAD WORK ............................................................................................... 445-451
Hard standing and pavement ............................................................................................................ 445
Bituminous macadam .......................................................................................................................... 445
Bituminous macadam .......................................................................................................................... 446
Dense/semi dense asphaltic concrete .............................................................................................. 446
Concrete road, runway and hard-standing (flexural concrete only) ........................................ 447
Joints in pavement and hard standing ............................................................................................. 448
Finishes to concrete roads, pavings, etc. .......................................................................................... 450
Materials (supply only) ........................................................................................................................ 450
Pre-formed filler .............................................................................................................................. 450
Joints sealing compound material ............................................................................................... 450
SECTION 21 : DEMOLITION AND DISMANTLING ................................................... 452-463
Special conditions ................................................................................................................................. 452
Brickwork and masonry ...................................................................................................................... 453
Jack arches and reinforced brickwork .............................................................................................. 454
Stone and brick pavings/floors .......................................................................................................... 454
Cleaning bricks, stones, etc. ................................................................................................................ 455
Concrete in situ ..................................................................................................................................... 455
Wood work and joinery ...................................................................................................................... 456
Steel and iron work .............................................................................................................................. 457
Roof and wall coverings, ceilings and linings ................................................................................. 458
Miscellaneous ........................................................................................................................................ 460
Drains ...................................................................................................................................................... 461
Removing building materials .............................................................................................................. 462

CONTENTS

XI

SECTION 22 : HEATING, VENTILATION AND AIR CONDITIONING ............... 464-482


Air handling unit .................................................................................................................................. 464
Air curtains ............................................................................................................................................ 466
Cooling towers ...................................................................................................................................... 468
Air cooled reciprocating chillers ........................................................................................................ 469
Air cooled screw chillers ..................................................................................................................... 470
Water cooled screw chillers ................................................................................................................ 471
Air cooled scroll chiller ........................................................................................................................ 473
Water cooled scroll chillers ................................................................................................................. 473
Water cooled centrifugal chiller ......................................................................................................... 473
Duct insulation ...................................................................................................................................... 474
PGI sheet duct ........................................................................................................................................ 475
Package unit ........................................................................................................................................... 475
MS pipes ................................................................................................................................................. 476
PUF insulation for MS pipe ................................................................................................................ 476
Pre insulated MS pipes ........................................................................................................................ 476
Underdeck insulation ........................................................................................................................... 477
VLT HVAC drive .................................................................................................................................. 478
Walk - in cold room & mortuary cabinet ......................................................................................... 479
Ice making machine ............................................................................................................................. 480
Appliances .............................................................................................................................................. 480
Water cooler ........................................................................................................................................... 481
Split AC unit .......................................................................................................................................... 481
SECTION 23 : LIFTS .................................................................................................................. 483-484
SECTION 26 : SOLAR WATER SYSTEM .................................................................................... 485
SECTION 27 : FIRE HYDRANT, FIRE DETECTION AND ALARM SYSTEM
FIRE HYDRANT AND SPRINKLER SYSTEM ...................................... 486-492
Pumps ...................................................................................................................................................... 486
Water pipes ............................................................................................................................................ 487
Fire detection and alarm system ........................................................................................................ 490
SECTION 28 : INCINERATOR ...................................................................................................... 493
SECTION 29 : RAIN WATER HARVESTING ................................................................... 494-495
Roof covering ......................................................................................................................................... 494
Composite rain water harvesting system ........................................................................................ 495

SECTION 8

XIII

Cont. from page 163

SECTION 8JOINERY
[k.M 8& c<bZfxjh
SUSPENDED CEILINGS
METAL FRAMED SUSPENDED CEILING (SEAMLESS FINISH) :
Soffit Cleat
Nut & Bolt

Perimeter Channel

Ceiling angle at 1220mm


max centre

Dry Wait Screw

Connecting Clip
Ceiling Section

Intermediate Channel
at 1220 max Centre
Calcium Silicate Board

GENERAL ASSEMBLY

Ceiling Angle
Nut & Bolt

Intermediate Channel

Perimete Channel
Ceiling Section

Self Drilling & Taping Screw

Calcium Silicate Board

PERIMETER DETAILS
Components

Soffit Cleat

Connecting Clip
Metal row plug

Intermediate Channel

Ceiling Hanger

Ceiling Section

Perimeter Channel

Self driling screw


with underhead cutter

XIV

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh

Componet Details:
Components

Size in mm.

Application

Perimeter Channel

Web:27 Flange: 20 &30


Thickness: 0.55

Fixed to the perimeter of the wall / partition

Intermediate Channel

Web:45 Flange: 15 each


Thickness: 0.91

Suspended from the soffit @ 1220mm c/c with ceiling


hanger.

Ceiling Section

Web:50.5 Flange: 26each


Thickness: 0.55

Fixed across to the intermediate channel @ 457mm


c/c with connecting clips, to hold the boards

Ceiling hanger

Flange: 10 & 25mm each


Thickness: 0.50

Used to suspend Intermediate channel from soffit


cleat.at 1220mm centres.

Connecting Clip

2.64 dia.

It is used to hold the ceiling section to the intermediate


channel.

Soffit Cleat

Web:25 Flange: 37 &25


Thickness: 0.55

Used at 1220mm c/c to the roul plug to suspend


ceiling hanger.

Row Plug

12.7 dia.

Used @1220mm c/c in both direction

Screws - self drilling &


tapping screws with under
head cutter.

25 & 35 long

Used to fix boards to the metal frame @200mm c/c


(12mm away from the edge and 40mm from the
corners.)

EXPOSED GRID SYSTEM


Cross T Section (Bottom
Precoated) 600mm/
1200mm

Wall Angle
Precoated

Wall

Calcium Silicate Board

Main T Section
(Bottom Precoated)
600mm c/c

Calcium Silicate Board


595 x 595mm or 595 x 1195mm

T Section
Wall Angle

595 x 595mm or 595 x 1195mm


ISOMETRIC VIEW

ARRANGEMENT (LAY IN GRID)

XV

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh

Componet:

G.I. Main T - 3600mm


Wall Angle

G.I. Cross T - 1200mm

Level Clip
with wire
Soffit Cleat

G.I. Cross T - 600mm

Metal Row Plug

Componet Details:
Components

Size in mm.

Application

Main "T"-3600

Web:25 Flange: 35
Thickness: 0.7

It is suspended from the soffit @1200mm c/c with


level clip.

Cross"T"-1200

Web: 25 Flange: 35
Thickness: 0.7

It is inserted fixed into the slots of main "T" @600mm


to form a grid of 1200x600mm.

Cross "T"-600

Web:25 Flange: 35
Thickness: 0.7

It is inserted fixed into the slots of cross "T" @600mm


to form a grid of 600 x 600 mm.

Wall Angle

Web: Flange: 25 each


Thickness: 0.7

Fixed to the perimeter of the wall / partition.

Level clip with wire.

Wire dia. 4mm

Used @ 1200mm c/c to hold the main "T"

Soffit Cleat

Web:25 Flange: 37 &25


Thickness: 1.8

Used at 1200mm c/c to the roul plug to suspend


level clip with wire.

Row Plug

12.7 diameter.

Used @1200mm c/c in both directions

XVI

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
PER RUNNING METER
18353 Supplying and laying of
CPVC pipes SDR 11 & Plain
CPVC SDR 11 fittings in
trenches complete all as

specified.
18354 --Ditto-but with SDR 13.5
pipes & plain CPVC SDR 11

fittings
18355 --Ditto-but with CPVC
Schedule 80 pipes & plain

CPVC Schedule 80 fittings


18356 --Ditto-but with CPVC
Schedule 40 pipes & Plain

Schedule 80 fittings
18357 Laying of CPVC pipes &
fittings any grade
in

trenches
18358 Supplying and laying of
CPVC pipes SDR 11 & Plain
CPVC SDR 11 fittings on
walls/ceiling or laying in
floors complete all as

specified.
18359 --Ditto-but with SDR 13.5
pipes & plain CPVC SDR 11

fittings
18360 --Ditto-but with CPVC
Schedule 80 pipes & plain

CPVC Schedule 80 fittings


18361 --Ditto-but with CPVC
Schedule 40 pipes & Plain

Schedule 80 fittings
18362 Laying of CPVC Pipes &
fittings on walls/ceiling or
laying in floors complete all

as specified.

STEEL WATER TUBING Contd...


yksgs dh ty ufydk tkjh
CPVC PIPE OUTER DIAMETER

CPVC PIPE INNER DIAMETERS

16mm

20mm

25mm

32mm

40mm

50mm

62.5mm

75mm

100mm

150mm

81.10

99.00

130.10

181.80

258.80

407.30

72.50

91.80

115.60

158.30

238.60

328.60

1349.60

1810.80

2678.40

6762.70

1028.60

1331.50

1885.10

3880.00

12.00

14.80

18.50

20.80

23.10

25.50

27.80

30.10

34.70

46.30

92.50

111.40

144.10

200.30

280.60

438.20

83.30

103.70

128.70

174.10

233.90

355.10

1434.50

1929.30

2852.60

7167.50

1095.20

1422.90

2015.20

4129.10

13.90

16.20

18.50

20.80

23.10

25.50

27.80

30.10

34.70

46.30

Extra over item No. 18353 to Item No. 18362 for provision of special fittings (Brass elbow, Brass Tee, Male
threaded brass adaptor, Female threaded brass adaptor etc), Unions, Ball valves, Flange and tank adaptor).

18363
18364
18365
18366
18367
18368
18369
18370
18371

EACH
Fitting Description

Brass Elbow
Brass Elbow (3/4 X )

Brass Tee
Male Brass Threaded

Adaptor (MTA/ MBTA) )


Female Brass Threaded
Adaptor (FTA/ FBTA)

Tank Adaptor

UNION

BALL VALVE

CPVC Flange

CPVC PIPE OUTER DIAMETER

CPVC PIPE INNER DIAMETERS

16mm

20mm

25mm

32mm

40mm

50mm

62.5mm

75mm

100mm

150mm

36.80

47.40

--

--

--

--

--

--

--

--

42.60

--

--

--

--

--

--

--

--

46.70

81.80

--

--

--

--

--

--

--

--

86.60

111.30

184.20

380.80

444.70

914.90

589.00

822.70

1273.20

--

83.20

112.70

153.30

373.90

415.90

813.20

796.70

954.10

1908.20

--

64.60

78.40

122.40

170.50

191.80

298.30

---

--

--

--

--

99.00

145.80

172.50

228.20

327.90

591.20

--

--

--

--

268.00

306.60

325.10

763.00

971.30

1249.70

--

--

--

--

839.15

1196.65

1630.20

1630.20

3236.35

SECTION 1

MILITARY ENGINEER SERVICES

lsuk bathfu;j lsok;sa


STANDARD SCHEDULE OF RATES 2010

njksa dh ekud vuqlp


w h 2010
PART II RATES

Hkkx

II

njsa

(hereinafter referred to as the S.S.R.)


rnqijkar bls **,l- ,l- vkj-** ds uke ls lanfHkZr fd;k x;k gS

SECTION 1
GENERAL RULES
[k.M 1 lkekU; fu;e
1.0 These general rules shall be applicable to all Sections to the
extent the context permits and are intended to supplement
the provisions in the particular section. In case of any
discrepancy, the provision in the particular Section shall
take precedence.

1-0 ;g lkekU; fu;e lHkh [kaMksa ij ml lhek rd ykxw gksxa s tgka rd


fd izdj.k vuqefr nsrk gS rFkk budk ms; ml fof'k"V [kaM dh
O;oLFkkvksa dh vuqifw kZ djuk gSA fdlh Hkh vlaxfr dh fLFkfr esa bl
[kaM dh O;oLFkk;sa gh ekU;rk izkIr djsx
a hA

1.1 Area of Applicability:


This SSR is applicable for whole country.

1-1 iz;ksT;rk ds {ks= %&


;g ,l ,l vkj iwjs ns'k esa ykxw gksxkA

1.2 Interpretations:

1-2 O;k[;k %&

(a) The Engineer-in-Chief, Army Headquarters, shall be


the sole deciding authority as to the meaning,
interpretation and implications of various provisions
of the S.S.R. His decision in writing shall be final and
binding.

v vfHk;ark ize[q k] lsuk eq[;ky;] ,l ,l vkj dh fofHkUu O;oLFkkvksa


ds vFkZ] O;k[;k rFkk rkRi;Z ds fo"k; esa vafre fu.kkZ;d vf/kdkjh
gksx
a As mudk fyf[kr esa fn;k x;k fu.kZ; vafre rFkk ck/; gksxkA

(b) If there is any discrepancy in meaning of English and


its Hindi version in SSR, the English words and
meanings as understood or as inter-preted shall take
precedence.

c ;fn ,l-,l-vkj-esa fdlh 'kCn ds fgUnh ;k vaxzsth rkRi;Z esa


folaxfr gks rks vaxzsth 'kCn o mlds vFkZ dks izkFkfedrk nh
tk;sxhA

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
1.3 Definitions:The following terms and expressions in the SSR, shall
have the meaning or implications hereby assigned to them
unless mentioned otherwise elsewhere :

1-3 ifjHkk"kk;sa %&


,l ,l vkj esa fuEufyf[kr 'kCn o vfHkO;fDr;k, muds fy, fu/kkZfjr
rkRi;Z ds vFkZ ls gh tkuh tk;sxh tc rd fd dgha nwljs izdkj ls
u dgk x;k gksA

(1) Ditto

The whole of the work described in the


item immediately preceding the word but
subject to any modification which may be
specifically mentioned.

1 mi;qZDr

en esa of.kZr og laiw.kZ dk;Z tks 'kCn ds rqjUr


igys vkrk gS fdUrq :ikarfjr ftl dk o.kZu
fd;k tkuk pkfg,A

(2) (Ditto)

The word or words, etc., enclosed in


brackets in the item immediately
preceding.

2 mi;qZDr

'kCn ;k vusd 'kCn vkfn tks rqjUr igys okyh


en esa dks"Bd esa fn;s x;s gksaA

1 tc ,d lafonk dh fof'k"V vuqlwph esa


'kkfey lkexzh dk ,e bZ ,l }kjk iznk lkexzh
ds lanHkZ esa iz;ksx fd;k x;k gks rks ;g og LFkku
gksrk gS tgka ls ml vuqlp
w h esa of.kZr og lkexzh
iznku dh tkrh gSA
(2) In cases other than those mentioned
2 mijksDr 1 esa of.kZr fLFkfr;ksa ds vfrfjDr
in (1) above-Any M.E.S. Store or place
,e bZ ,l dk dksbZ Hk.Mkj ;k tek djkus dk og
of deposit within the contract Area or
LFkku tks lafonk ds ifj{ks= ds vUnj vkrk gks ;k
the nearest M.E.S. Store at the
izHkkjh vfHk;ark ds foosdkuqlkj ,e bZ ,l dk
discretion of the Engineer-in-Charge,
lcls utnhd dk Hk.Mkj tc rd fd lafonk esa
unless a particular store is mentioned
in the contract.
fdlh fo'ks"k Hk.Mkj dk o.kZu u gksA
(4) Materials The provision of all materials and labour 4 lkexzh o Je laiw.kZ lkexzh o Jfedksa dh O;oLFkk rFkk en esa
and
and the performance of all workmanship
of.kZr dk;Z ds leqfpr fu"iknu ds fy, vko';d
Labour
necessary for the proper execution of the
lHkh dk;Z dkS'ky dk ikyu rFkk og lHkh O;oLFkk;sa
work as described in the item and for all
tks 1-13 esa of.kZr gSaA
the provisions described in 1.13.
(3) Stores,
M.E.S.
Stores

(1)

(5) Labour
only,
Except
Materials

As defined for materials and labour


except for the provision of materials (which
will be supplied Free of cost for
incorporation in the work), but including
the removal, by the contractor from the
M.E.S. Store, of all materials provided by
the M.E.S. and where applicable, storing
under cover as required, closing, preparing,
loading and returning empty cases or
containers to the place of issue without any
extra charge.

(6) Except
bricks,
Except
timber,
Materials
supplied
by M.E.S.
free
of cost,
etc.

As defined for materials and labour


except the provisions of the materials
(which will be supplied Free of cost for
incorporation in the work) specifically
exempted, but including the removal, by
the contractor from the M.E.S. Store, of the
materials provided by the M.E.S. and
where applicable, storing under cover as
required, closing, preparing, loading and
returning empty cases or containers to the
place of issue without any extra charge.

When used in connection with the


materials included in the appropriate
Schedule of a contract for issue by the
M.E.S.; the place of issue mentioned
in that Schedule.

3 Hk.Mkj]
,ebZ,l
Hk.Mkj

5 fcuk lkexh] tSlk fd **lkexzh o Je** ds fy, ifjHkkf"kr


dsoy Je fd;k x;k gS fcuk lkexzh dh O;oLFkk ds ftldh
vkiwfkZ] dk;Z esa 'kkfey djus ds fy,] fu%'kqYd
dh tk;sxh] fdUrq ,e bZ ,l }kjk iznk laiw.kZ
lkexzh dks Bsdsnkj }kj ,e bZ ,l Hk.Mkj ls ys
tkuk o tgka vko';d gksa ogka visf{kr vkoj.k
ds vUnj j[kuk] can djuk] rS;kj djuk] Hkjuk
vkSj [kkyh MCcksa ;k ik=ksa dks fcuk vfrfjDr
izHkkj ds iznk LFkku ij okfil djuk 'kkfey
gSA
6 fcuk bZV]
tSlk fd **lkexzh o Je** ds fy, ifjHkkf"kr
fcuk yDdM+] fd;k x;k gS fcuk lkexzh dh O;oLFkk ds ftldh
,ebZ,l }kjk vkiwfkZ] dk;Z esa 'kkfey djus ds fy, fu'kqYd dh
fu%'kqYd iznk tk;sxh] fdUrq ,e bZ ,l }kjk iznk laiw.kZ
lkexzh vkfn lkexzh dk Bsdns kj }kjk ,e bZ ,l Hk.Mkj ls ys
tkuk o tgk vko';d gks ogka visf{kr vkoj.k ds
vUnj j[kuk] can djuk] rS;kj djuk] Hkjuk vkSj
[kkyh MCcksa ;k ik=ksa dks fcuk vfrfjDr izHkkj ds
iznk LFkku ij okfil djuk 'kkfey gSA

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
tSlk fd lkexzh o Je ds fy, ifjHkkf"kr fd;k
x;k gS fcuk oLrqvksa dh O;oLFkk ds ftudh vkiwfkZ]
dk;Z esa 'kkfey djus ds fy, fu%'kqYd dh tk;sxh]
ftudks fLFkj djuk] fcNkuk ;k O;ofLFkr djuk
'kkfey gS fdUrq ;fn vko';d gks rks oLrqvksa dks ,e
bZ ,l Hk.Mkj ls ykuk vkSj en esa of.kZr dk;Z ds
leqfpr fu"iknu ds fy, vko';d lgk;d lkexzh
fdUrq ftudh vkiwfrZ eq[; oLrq ds Hkkx ds :i esa
ugha dh xbZ gS tSls dhy]sas isp] ljsl] can djus]
tksMu+ s o cka/kus dh lkexzh tSls lkeku dh O;oLFkk
djuk tc rd fd vU;Fkk fo'ks"k :i ls izFkd u
fd;k gksA bues]a tgka ykxw gksrk gks ogka can djuk]
rS;kj djuk] mBkuk rFkk ,e bZ ,l }kjk iznk
oLrqvksa ds [kkyh fMCCksa o ik=ksa dks iznk LFkku ij
fcuk vfrfjDr izHkkj ds okfil djuk 'kkfey gSa
(8) Add if All materials, labour, tools, plant, 8 tksMa+s ;fn
lai.w kZ lkexzh] Jfed] vkStkj l;a= ikM+ o midj.k
scaffolding and appliances required for
in
lq/kkj es]a
ftudh vko';drk iqjkuh oLrqvksa MakVsa] idM+
repairs, taking out the old article (including plugs,
tks
M
a
s
+
;fn
ikh
vkfn dks fudkyus esa gksrh gS rFkk ;fn vko';drk
holdfasts, etc.) removal of the old article to
Add if
LFkkiu
gks
rks
iqjkuh oLrqvksa dks ,e bZ ,e Hk.Mkj esa
fixed in the M.E.S. Store, if required, making good
lq
/
kkj
es
a
igq

p
kuk
rFkk LFkkiu ds dke ds fo?kfVr LFkku
repairs all work disturbed at fixing, and obtaining
access, by raising or removing covers, to
dks Bhd djuk rFkk igqp
cukus ds fy,] la;kstuksa
fittings etc., and replacing covers on
vkfn ls vkoj.k mBkuk ;k gVkuk o dk;Z lekfIr
completion.
ij mUgsa ;FkkLFkku ij j[kukA
As defined for Fixing only and in 9 lq/kkjksa esa
(9) Fixing
tSlk fd dsoy LFkkiu esa ifjHkkf"kr gS rFkk
only in addition as defined for Add if in repairs.
dsoy LFkkiu tSlk fd tksM+as ;fn ejEer esa ifjHkkf"kr gSA
(7)

Fixing
only,
Laying
only,
Setting
only

As defined for materials and labour except


for provision of the articles (which will be
supplied Free of cost for incorporation in the
works), to be fixed, laid or set, but including
removal of the articles from the M.E.S. Store,
if required, and the provision of materials
necessary for the proper execution of the
work, as described in the item which are
subsidiary to, but are not supplied as part of
the principal article, such as nails, screws,
glue packing, jointing, and beading materials
and the like, unless otherwise specifically
excluded. These also include for, where
applicable, closing, preparing, loading and
returning, empty cases or containers of the
articles provided by the M.E.S. to the place of
issue without any extra charge.

repairs
(10) Patch or A portion of the existing work to which a
partial replacement, renewal or repair is
in
patches effected and to which the patch is
intimately connected.The expressions are
not applicable to work in small quantities/
narrow widths in new work.
(11) Transport, Conveyance by any mode or means
carriage, including loading, unloading, reloading,
cartage etc.
Includes any hoisting or lowering by any
(12) Raise,
Raising mode or means.
or
Lowering
(13) Measured It means that the materials and/or labour
so described is not included in the rate for
sepathe item, but will be measured separately.
rately
(14) Best

With reference to quality of material and


workmanship, when possible, the standard
required shall be specified in preference to
the expression Best. The word Best
when used shall mean that, in the opinion
of the G.E., there is no superior material/
article and workmanship obtainable in the
market and trade respectively.

7 dsoy LFkkiu]
dsoy fcNkbZ]
dsoy
O;OkfLFkr
djuk

10 isou ;k
isouksa esa

fo|eku dk;Z dk ,d Hkkx ftlesa vkaf'kd :i ls


izfrLFkkiu] uohuhdj.k ;k ejEer dh xbZ gS
rFkk ftlesa isou dks iwjh rjg ls feyk fn;k gSA
;g vfHkO;fDr;k NksVh ek=k ds dk;ksZa@rax
pkSMkbZ ds uohu dk;ksZ ij ykxw ugha gksrhaA

11 ifjogu]
okgu] HkkM+k

fdlh Hkh fof/k ;k lk/ku }kjk ifjogu esa lkeku


Hkjuk] mrkjuk] iqu% Hkjuk vkfn 'kkfey gSA

12 mBkuk o
mBkus dk
dk;Z

blesa fdlh Hkh rjg ;k lk/ku ls ij


mBkuk ;k uhps ykuk 'kkfey gSA

13 izFkd ekik
tk;sxk

bldk vFkZ ;g gS fd of.kZr lkexzh rFkk ;k Je


ml en dh njksa esa 'kkfey ugha gS vr% izFkd
ekik tk;sxkA

14 loksZ ke

lkexzh dh xq.koRRkk rFkk dk;Z dq'kyrk ds lanHkZ esa tc


laHko gks rks vis{kkd`r loksZ ke 'kCn ds vko';d ekud
dks fufnZ"V fd;k tk;sxkA tc 'kCn loksZ ke dk
iz;ksx fd;k tkrk gS rks bldk vFkZ ;g gksxk fd nqxZ
vfHk;ark ds fopkj esa cktkj o O;kikj esa dze'k% mke
lkexzh@oLrq rFkk dk;Z dq'kyrk miyC/k ugha gSA

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
(15) Local

The word Local when used with


reference to material/article shall mean
the best (at the discretion of G.E.) of its kind
available and used in the locality (i.e.
within a distance of 40 km from the
boundary of the site of work, unless
specified to the contrary in the tender
documents).

15 LFkkuh;

tc lkexzh@oLrq ds lanHkZ esa LFkkuh; 'kCn dk


iz;ksx fd;k tkrk gS rks bldk vFkZ gksxk fd vius
izdkj dh loksZ ke nqxZ vfHk;Urk ds foosdkuqlkj
miyC/k gS rFkk izn's k esa iz;Dq r gksrh gS vFkkZr
dk;ZLFky dh lhek ds 40 fdeh- ds vUnj] tc
rd fd fufonk nLrkostksa esa foijhr fufnZ"V u gksA

(16) Site

The land and/or place on, in, into or


through which work is to be executed
under the contract, or any adjacent land,
path or street, which may be allotted or
used for the purpose of carrying out the
contract.

16 dk;ZLFky

og tehu o@;k LFkku ftl ij ftles]a chp ;k


vk|ksikUr esa lafonk ds vUrxZr dk;Z gksuk gS ;k
dksbZ fudVorhZ tehu] jkLrk ;k xyh] tks lafonk
dk;ksZ dks iwjk djus ds fy, vkoafVr ;k iz;qDr
fd;s tk ldrs gSaA

17 Bsdns kj

og O;fDr] ;k QeZ] ;k dEiuh] pkgs fuxfer gS


;k ugha] ftlus dk;Z djus dk mkjnkf;Ro fy;k
gS rFkk og O;fDr] tks ,sls O;fDr dk dkuwuh :i
ls izfrfuf/k gks] ;k ,sls O;fDR;ksa dk lewg tks ,slh
QeZ ;k dEiuh ds gSa ;k ,sls O;fDr] QeZ ;k
dEiuh dh mkjkf/kdkjh ;k lEifk ds izkf/kd`r
izkIr drkZ gksaA

18 lh- bZ-@
lhbZ

lacfU/kr eq[; vfHk;Urk

(17) Contrac- The individual or firm or company,


whether incorporated or not, undertaking
tor
the Works and shall include the legal
personal representatives of such
individual or the persons composing such
individual or firm or company or the
successors of such individual or firm or
company and the permitted assigns of
such individual or firm or company.
(18) C.E./

Chief Engineer concerned.

(19) C.W.E./ Commander Works Engineer concerned.


CWE
(20) G.E./
GE

Garrison Engineer concerned.

(21) E.I.C./
EIC

Engineer-in-Charge, appointed by the G.E.


to supervise the works or part of the works.

The approval or direction of the C.W.E. or


(22) Approved/ G.E. or person deputed by him for the
particular purpose.
Dir
ected

19 lh- MCy;w- bZ lacfU/kr lekns'kd dk;Z vfHk;Urk


@lh MOY;w bZ
20 th- bZ-@
lacfU/kr nqxZ vfHk;Urk
thbZ
21 bZ-vkbZ-lh-@ nqxZ vfHk;ark }kjk dk;Z ;k mlds Hkkx ds i;Zo{s k.k
bZvkbZlh ds fy, fu;qDr vfHk;UrkA
22 Lohd`r@
funsfZ 'kr

leksns'kd dk;Z vfHk;ark ;k nqxZ vfHk;ark ;k


mlds }kjk fo'ks"k iz;kstu ds fy, fu;qDr
izfrfuf/k dh Lohd`fr ;k vkns'kA

(23) Indicated/
as
indicated

As shown in drawing, particular


specifications, work order or deviation
order.

23 lwfpr@
tSlk fd uD'ks] fo'ks"k fofunsZ'kuksa] dk;Z vkns'k
tSlk lwfpr ;k fopyu vkns'k esa fn[kk;k x;k gksA

(24) Specially
Orde
red

Separately ordered in writing for the


particular item(s) only, in addition to the
usual Works Orders, Requisitions, etc.

24 fo'ks"kr%
vknsf'kr

vke dk;Z vkns'kksa] izkFkZuk vkfn ds vfrfjDr


dsoy fo'ks"k en enks ds fy, fyf[kr :i esa
izFkd fn;s x;s vkns'kA

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
(25) M.E.S./ Military Engineer Services
MES

25 ,e- bZ- ,l- lsuk bathfu;j lsok;saA

(26) M.D./
MD

Government of India (Ministry of Defence).

26 ,e- Mh-

Hkkjr ljdkj j{kk ea=ky;A

(27) Month

A Calendar Month.

27 ekg

iapkax ekl

28 ,e- Mhifjlj

vuqlwph esa ,e Mh ifjlj ;k ifjlj 'kCn


dk tgka Hkh iz;ksx gqvk gS mldk vFkZ fdlh Hkh
,sls ifjlj ls gS pkgs og Hkkjr ljdkj ds
LokfeRo esa gks vFkok ugh ftl ij ,e-bZ-,l- ds
i;Zos{k.k esa dk;Z fd;k tk jgk gksA

The term M.D. premises or premises,


(28) M.D.
Premises where used in the Schedule means any
premises (whether owned by Government
of India or otherwise) on which work is
carried out under the supervision of the
M.E.S.
(29) S.S.R/
SSR

Standard Schedule of Rates.

29 ,l ,l vkj njks dh ekud vuqlwph

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
1.4 Abbreviations:The following abbreviations, wherever they appear
in the S.S.R., shall have the meaning or implication
hereby assigned to them:-

1-4 laf{kfIr;ka %&


njksa dh ekud vuqlp
w h esa tgka dgha Hkh fuEufyf[kr laf{kfIr;ka vkrh
gSa( rks mudk vFkZ o rkRi;Z ogha gksxk tks ;gka fn;k x;k gS%&

1.
2.

1234567891011121314151617181920212223242526272829303132333435363737-A
37-B
383940-

Average
avg.
Aluminium Conductor
Steel Reinforced
A.C.S.R.
3.
All-Aluminium Conductor
A.A.C.
4.
Alternating Current
A.C.
5.
Air Break
A.B.
6.
Bayonet Cap
B.C.
7.
Cubic metre
m3/Cu m /Cu. m
8.
Cubic Centimetre
cm3/cc/cu.cm
9.
Cord Grip
C.G.
10. Centimetre
Cm/cm
11. Cubic
Cu
12. Diameter
dia.
13. Degree centigrade Celsius
C
temperature
14. Direct Current
DC
15. Double Pole
DP
16. Etcetera
etc./etc.
17. Exceeding
exc/exc./Exc./Exc
18. Edison Screw
ES
19. Figure
Fig.
20. For example
e.g.
21. Gram/Gramme
g.
22. Goliath Screw
G.S.
23. High Tension
HT
24. Iron Clad
IC
25. Iron Clad Triple Pole
ICTP
26. Kilogram
Kg
27. Kilolitre
Kl
28. Kilometre
Km
29. Kilovolts
KV
30. Kilovolt Amps
KVA/kva
31. Litre
l
32. Labour only
L.O.
33. Long Way Mesh
LWM
34. Low Tension
LT
35. Metre
M/m.
36. Material and Labour
M&L
37. Millimetre
Mm/mm
37.A Miniature Circuit Breaker
MCB
37.B Moulded case Circuit Breaker MCCB
38. Namely
viz.
39. Not exceeding
n.exc./n exc./
N.exc/N exc.
40. Number
No./No/no./no

vkSlr
vY;qfefu;e lapkyd yksgs izofyr
iw.kZ vY;qfefu;e lapkyd
izR;kokhZ djaV
ok;q fo;kstu
laxhu Vksih
?ku ehVj
?ku lSaUVhehVj
Mksjh ca/ku
lSVa hehVj
?ku
O;kl
foHkDr lSyfk;l rkieku
fnV /kkjk
f}[kaHkk
vidkZd
vf/kd
lapkyd isp
vkdkj
mnkgj.kkFkZ
xzke
cM+k isp
mPp ruko
yksgNkfir
yksfgr f=kk[kk [kaHkk
fdyksxkze
fdyksfyVj
fdyks ehVj
fdyks ckYV
fdyks ckYV ,Eis;j
fyVj
dsoy Je
nh?kZekxZ fNnz
fuEu ruko
ehVj
lkexzh o Je
feyh ehVj
fefu,pj ldZV Ckszdj
eksfYMM dsl ldZV Ckszdj
vFkkZr
vuf/kd
la[;k la[;k;sa

vkSlr
, lh ,l vkj
, , lh
, lh
, ch
laVks
?k eh
?k lSlh th
la Vh
?ku
O;kl
lh
fn /kk
Mh ih
vid
vf/k
1 bZ ,l
vkd`
mnkg
xzk
th ,l
mr
yks Nk
yks f= kk
fdxzk
fdfy
fdeh
fdck
fdok,Ei
fy
dJ
fn ek fN
fur
fe@eh
lk o Je
feeh
,e lh ch
,e lh lh ch
;kuh
vu
la-

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
41.
42

Plain Cement Concrete


Paper Insulated Lead
Covered
43.
Paper Insulated Lead
Covered Armoured
44.
Polyvinyl-Chloride
44.A Pre- Engineered Building
45.
Quintal
46.
Reinforced Cement Concrete
46.A Ready mixed Concrete
47.
Rupee
48.
Rupees
49.
Shade Carrier or Single Core
50.
Supply and fix or Supplied
and fixed
51.
Single Pole
52.
Square metre
53.
Square
54.
Short Way Mesh
55.
Standard Wire Gauge
56.
Triple Pole
57.
Tonne
58.
that is
59.
Teak Wood
60.
Tough Rubber Sheathed
61.
Under Ground
62.
Vulcanised India Rubber
63.
WeatherProof

PCC
PILC
PILCA
PVC
PEB
q/qtl
RCC
RMC
Re
Rs.
SC
S&F
SP
m2/sqm./sqm
Sq/sq.
SWM
SWG
TP
t.
i.e.
TW
TRS
UG
VIR
WP

1.5. Materials Supplied only:1.5.1 The rates for Materials Supplied only at the end of
each Section shall apply:(a) For pricing of work executed by the Contractor,
where supplied only rates are applicable
according to the provision in the S.S.R.
(b) For the preparation of Proportional Rates.
1.5.2 The rates do not apply for the purchase of stores by
the M.E.S. from the Contractor.
1.5.3 The rates shall be deemed to be inclusive of the
following:
(a) Delivery at the M.E.S. Store or site of work.
(b) Stacking in regular stacks for measurement or
counting (according to the nature of materials).
(c) Sizes and lengths available with the M.E.S. in
case of supply by M.E.S.
1.5.4 Rates for materials which are common to more than
one Section of S.S.R., have been given, generally, in
one Section. They shall apply to other sections
unless they are not appearing in that particular
section.
1.5.5 The material supplied by M.E.S. shall be deemed to be
complying with the specifications given in the S.S.R.

41- lknh lhesaV dahV


42- dkxth /kkjk vojks/kd lhlk p<+k
43- dkxth /kkjk vojks/kd lhlkbZ dop
44- ikWyh foukbZy DyksjkbM
44-A izh bafUtfu;jM fcfYaMx
45- fDaoVy
46- izofyr lhesaV dahV
46-A jsMh feDlM dahV
47- :i;k
48- :i;s
49- Nk;k okgd ,dy/kkjk
50- vkiwfrZ o fLFkj
51- ,dy [kaHkk
52- oxZ ehVj
53- oxZ
54- vYi ekxhZ tkyh
55- ekud rkj tkyh
56- f=/kkjk [kaHkk
57- Vu
58- vFkkZr
59- lkxoku dh ydM+h
60- l[r jcM+ dk vkoj.k
61- HkwfeLFk
62- xU?kd nskh jcM+
63- _rq lg

l lh da
dk/kk v lh p
ih vkbZ ,y lh ,
ih oh lh
ih bZ ch
fda
iz lh da
vkj ,e lh
:i
:is
N o , /kk
vk o fLFk
, [ka
oeh
oxZ
v Hkk tk
ek rk tk
f= /kk [ka
Vu
vFkkZr
lk y
l j yk
HkwLFk
x ns j
_l

1-5 dsoy lkexzh dh vkiwfkZ %&


1-5-1 lkexzh ds fy, **dsoy vkiwfkZ** dh izR;sd [kaM ds vUr esa nh
xbZ njsZa ykxw gkasxh%&
d Bsdsnkj }kjk fuikfnr dk;Z dk ewY; vkadus ds fd,]
tgka njksa dh ekud vuqlwph ds izko/kku ds vuqlkj]
**dsoy vkiwfrZ** dh njsZa ykxw gSaA
[k vkuqikfrd njsa rS;kj djus ds fy,A
1-5-2 ,e bZ ,l }kjk Bsdsnkj ls lkeku [kjhnus ij ;g njsa ykxw
ugha gSaA
1-5-3 njksa esa fuEufyf[kr dks kkfey ekuk tk;sxk%&
d ,e bZ ,l Hk.Mkj ;k dk;ZLFky ij fuiknuA
[k eki ;k fxurh djus ds fy, ;Fkkdze <sjksa esa pV~Vs
yxkuk lkexzh dh fdLe ds vuqlkj
x ,e bZ ,l vkiwfkZ ds lEcU/k esa ,e bZ ,l ds ikl
miyC/k vkdkj o yEckbZA
1-5-4 mu lkefxz;ksa dh njsa tks ,l ,l vkj ds ,d ls vf/kd [k.Mksa
esa lkekU; gS( mUgsa vkerkSj ls ,d gh [k.M esa fn;k x;k gSA
os vU; [k.Mksa ij Hkh ykxw gksxh tc rd fd mUgsa ml foksk
[k.M esa u nkkZ;k x;k gksA
1-5-5 ,e bZ ,l }kjk nh xbZ lkexzh dks ,l ,l vkj esa fn;s x;s
fofunsZakksa ds vuq:i ekuk tk;sxkA

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
1.5.6 The rates for materials supplied only are
inclusive of the cost of any cases/ drums/
containers/any type of bags etc. and these shall be
non returnable. Where ever the issue of items is
stated, to be returnable containers/packing drums/
any type of bags etc. in items of SSR, this shall stand
modified to read as non returnable.

1-5-6 *dsoy vkiwfkZ* dh xbZ lkexzh essa dSls Hkh MCcs@Mje@cDls@


fdlh Hkh izdkj ds FkSys lfUufgr gSa vkSj mUgsa okfil ugh fd;k
tk;sxkA tgka dgha Hkh ,l ,l vkj dh en esa fuxZe oLrq
MCcs@Mje@cDlksa@fdlh izdkj ds FkSys vkfn dks okfil
djus ;ksX; dgk x;k gS mls vc lakksf/kr :i es okfil u
djus ;ksX; i<+k tk;sxkA

1.5.7 The Contractor shall be responsible for the safe


custody of all materials from the time they are issued
to him by the M.E.S. Any breakage, damage or loss
of materials issued free for fixing, shall be made
good by him to the satisfaction of the G.E.

1-5-7 Bsdns kj lkexzh dh lqjf{kr laHkky ds fy, ml le; ls gh mkjnk;h


gksxk ftl le; og mls fuxZe dh tkrh gSAa lkexzh tks LFkkiu ds
fy, fukqYd nh xbZ gS mldh VwV QwV] {kfr o [kksus s dh iwfkZ mls
nqxZ vfHk;ark dh larfq Vuqlkj djuh gksxhA

1.6

Old Materials:No extra charge shall be allowed for handling,


fixing, etc., of old materials as compared with new
materials except to the extent of the allowance
already included for such work in the S.S.R.

1-6 iqjkuh lkexzh %&


ubZ lkexzh dh rqyuk esas iqjkuh lkexzh dh laHkky o fLFkj.k
vkfn ds fy;s vfrfjDr Hkqxrku ugha fn;k tk;sxk flok; ml
NwV ds tks ,sls dk;Z ds fy, igys gh ,l ,l vkj esa kkfey
gSA

1.7

Directions:Instructions shall be given in writing for all


approved directions; no verbal instructions shall
be deemed to be binding nor shall such work be
measured.

1-7 funs Z k %&


lHkh Lohd`r funsZkksa ds fy, fgnk;rsa fyf[kr esa nh tk;saxhA
tokuh fgnk;rksa dks ck/; dj ugha ekuk tk;sxk vkSj uk gh ,sls
dk;Z dks ekik tk;sxkA

1.8

Alternatives:Where alternative materials, processes, etc., are


specified or mentioned in the S.S.R. the discretion
shall rest with the Contractor.

1-8 fodYi %&


tgka oSdfYid lkexzh] izf;k vkfn dks ,l ,l vkj esa
fofufnZV ;k mfYyf[kr fd;k x;k gks] ogka Bsdsnkj vius
foosd ls dke ysxkA

1.9

Measurements:Unless otherwise mentioned in the particular


Section the following shall apply :

1.9.1 Method of Measurements:1.9.1.1 All work executed under the S.S.R. shall be
measured in accordance with the instructions and
remarks detailed in the S.S.R. without reference
to any local custom or other practice or to any
other edition of the S.S.R.
1.9.1.2 Items, rates, descriptions of materials,
workmanship, modes of measurement, etc.,
contained in any previous edition of the S.S.R.
shall not constitute a precedent for purposes of
comparison with (or interpretation of) the contents
of this edition of S.S.R.

1-9 eki %&


tc rd fd fdlh foksk [k.M esa vU;Fkk mYys[k u gks rks
fuEufyf[kr ykxw gksxs%&
1-9-1 eki dh i+fr
1-9-1-1 njksa dh ekud vuqlp
w h ds vUrxZr fuikfnr lHkh dk;ksZ dh
eki] fcuk fdlh LFkkuh; fjoktksa ;k vU; jhfr;ksa ;k fdlh
,l ,l vkj ds vU; laLdj.k ds lanHkZ ds bl ,l ,l vkj
esa foLrkj ls nh xbZ fgnk;rksa o fVIif.k;ksa ds] vuqlkj dh
tk;sxhA
1-9-1-2 njksa dh ekud vuqlp
w h ds fdlh fiNys laLdj.k eas nh xbZ
ensa] njsa] lkexzh dk fooj.k] dk;Z dqkyrk] eki ds rjhds
vkfn dks ,l ,l vkj ds bl laLdj.k dh fok; oLrq dh
rqyuk djus ;k O;k[;k djus ds fy, iwoZ nzVkUr ugha
ekuk tk;sxkA

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
1.9.2 Net:All work shall be measured net, in the decimal
system, as completed or fixed in place with no
allowance (unless specifically provided for) for
cuttings, waste, joints risk, etc. No allowance shall
be made for large or small quantities, narrow widths,
easy or difficult positions, or other exceptional
circumstances except where specifically provided
for in the S.S.R. Any work done, by the contractor
extra over the dimensions indicated shall be ignored,
but where the dimensions are less than the specified
dimensions, then actual dimensions shall be
measured without prejudice to the right of the
Engineer-in -Charge to reject the work and order reexecution or replacements.

1-9-2 fokq+) %&


lHkh dk;ks Z a dks tS l s la i w f jr gq , gS a ;k LFkku es a LFkkfir
fd;s x;s gS a fokq ) ekik tk;s x k rFkk dVkbZ ] Nhtu]
tks M ks a dk tks f [ke vkfn ds fy, dks b Z Nw V tc rd fd
foks k:i ls ,s l h O;oLFkk u gks ugha nh tk;s x hA cM+ h
;k NksVh ek=k ds] rax pkSM+kbZ] vklku ;k dfBu voLFkkvkssa
;k vU; vioknkRed ifjfLFkfr;ksa dh dksbZ NwV ugha nh
tk;s x h] tc rd fd ,l ,l vkj es a s foks k:i ls
O;oLFkk u dh xbZ gksA fn;s x;s ifjeki ls Bsdsnkj }kjk
fd;s x;s vfrfjDr dk;Z dks /;ku es a ughs a fy;k tk;s x k
fdUrq tgka fufnZ V ifjeki ls ifjeki de gS rks iz H kkjh
vfHk;ark }kjk] dk;Z dks fujLr djus ;k nksckjk fuikfnr
djus] ;k iqu% LFkkiu ds vf/kdkj ds izfrdwy izHkko ds(
okLrfod ifjeki dks ekik tk;s x kA

1.9.3 Measurements
Unless otherwise provided for in the particular section
of the S.S.R., all work shall be measured as under:(a) Length and width shall be measured to nearest
0.01 m, the thickness shall be measured to
nearest 0.005 m or nearest to specified tolerance
whichever is less.
(b) Areas shall be worked out to the nearest 0.01 sq.m.
(c) Volumes shall be worked out to the nearest 0.01
cu.m.

1-9-3 eki
tc rd fd njksa dh ekud vuqlwph ds [k.M foksk esa vU;
O;oLFkk u gks lHkh dk;Z fuEu izdkj ls ekis tk;saxs%&
d yEckbZ o pkSM+kbZ dks fudVre 0-01 eh- rd ekik
tk;sxk] eksVkbZ dks izk;% 0-005 eh- rd ;k fu/kkZfjr NwV
tks Hkh de gks rd ekik tk;sxkA
[k {ks=Qy dh eki 0-01 oeh- rd yh tk;sxhA
x vk;ru dh eki fudVre 0-01 ?keh rd yh
tk;sxhA

1.9.4 Nearest
Wherever the word nearest is used in connection
with a unit of measurement, fractions half and above
(of the smallest unit upto which measurements are
specified to be taken) shall be reckoned as one and
fractions less than half (of the smallest unit upto
which measurements are specified to be taken) shall
be ignored.

1-9-4 fudVre
tgka dgha Hkh *fudVre* kCn dk iz;ksx eki dh ,d bdkbZ
ds lEcU/k esa fd;k tkrk gS( vk/ks ;k vf/kd vak eki ysus dh
fufnZfVre lcls NksVh bdkbZ dks ,d ekuk tk;sxk rFkk
vk/ks ls de vak eki ysus dh fufnZfVre lcls NksVh bdkbZ
dks NksM+ fn;k tk;sxkA

1.9.5 Transport or Carriage


The distance shall be measured by the shortest
practicable route as approved.

1-9-5 ogu ;k ifjogu


Lohd`r lcls NksVs O;kogkfjd ekxZ dk Qklyk ekik tk;sxkA

1.9.6 Record of Measurements


Where recording of measurements is necessary for
assessing payments to Contractors, Contractors
shall be held responsible, if they commence the
execution of any item of work which would prevent
the measurement of any of the work already done
until such measurements have been recorded in the
M.E.S. Measurement Books and are signed by the
Contractor and the M.E.S. representative. This shall
apply specially to foundations, steel built into the
work, and other similar hidden items.

1-9-6 eki dk vfHkys[k fjdkMZ


tgka Bsdns kj dks Hkqxrku ds fy, eki dk vfHkys[ku vko;d
gks ogka ;fn og fdlh ,slh en dk dk;Z vkjEHk dj pqds gksa
tks igys gq, dks ekius ls jksd ldrk gks] mlls igys fd ,slh
ekias ,e bZ ,l dh ekid iqLrd esa ntZ u gqbZ gksa rFkk Bsdns kj
o ,e bZ ,l ds izfrfuf/k ds gLrk{kj u gq;s gks]a rks blds fy,
Bsdsnkj Lo;a mkjnk;h gksxkA ;g uhoksa] dk;Z es yxs yksgs
rFkk ,sls gh Nqis dk;ksZa ij foksk:i ls ykxw gksrk gSA

10

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
1.10 Application of Rates : The rates in the S.S.R. are intended to apply to every
description of work that may be required in the
construction and maintenance of buildings of all
kinds belonging to, or acquired or hired or occupied
by the Government of India (M.D.) or for any work
carried out under the agency of the M.E.S., also
fortifications, roads, runways, parade and landing
grounds, drainage, water supply, electrical works,
and for work such as sea walls, groynes, harbour
and dock works bridges, railways, etc., where made
applicable.

1-10 njksa dh iz;qfDr ykxw djuk %&


njksa dh ekud vuqlwph dh njsa mu lHkh izdkj ds dk;ksZ ij
ykxw djus dh vfHkizj.s kk gS tks Hkkjr ljdkj j{kk ea=ky; ls
lacfa /kr ;k vf/kxzghr] ;k fdjk;s ij yh xbZ] ;k vkokflr lHkh
izdkj ds Hkouksa ds fuekZ.k o vuqj{k.k ;k ,e bZ ,l dh
vfHkdrZ`Ro vtSalh ds vUrxZr fd;s x;s dksbZ dk;Z rFkk
lqj{kk izcU/k dk;Z] lM+ds]a nkSMi+ Fk] ijsM o tgkt ih] ukyh
dk;ZZ] ty vkiwfrZ] fo|qr dk;Z rFkk ,sls dk;Z tSls leqnzh
nhokjs]a ty rksM+ canjxkg o xksnh dk;Z] iqy] jsyos vkfn] tgka
ykxw fd;k x;k gSA

1.10.1 All contractors are expected to have made inquiries


before tendering, and to have ascertained the nature
and extent of the work which they may be called
upon to perform under their contract.

1-10-1 lHkh Bsdsnkjksa ls vis{kk dh tkrh gS fd mUgksaus fufonk nsus


ls igys tkap dj yh gksxh rFkk Bsds ds vUrxZr tks dke
muls fy;k tkuk gS] og fdl izdkj dk gS vkSj fdruk gS
bldks lqfufpr dj fy;k gksxkA

1.11 Proportional and Star Rates


Subject to the over-riding provisions of the
conditions of contract, payment for work not
specifically mentioned in the S.S.R. shall be made
as follows:-

1-11 vuqikfrd rFkk fpfUgr LVkj njsa


Bsds dh kkksZ ds vUrxZr izko/kkuksa dks vf/kHkwr jh djrs gq,]
,sls dk;Z ftu dk ,l ,l vkj esa mYys[k ugha gS mudk
Hkqxrku fuEu izdkj ls gksxk%

1.11.1 Proportional (or Pro-rata) Rates based on analogous items in the S.S.R.
(1) Similar items of equivalent value:- If there are
analogous items in the S.S.R. for articles and/
or workman- ship of similar character and of
equivalent value, then at rates equal to the rates
of such items.
(2) Similar items differing in value:- If there are
analogous items in the S.S.R. for articles and/ or
workmanship of similar characters, but differing
in particulars and value, then at the rates for the
item as modified by the applicable price
variations, which shall be determined on the same
basis for both the items in S.S.R. and the new items
or where applicable at direct PRORATA rates
derived from the relevant S.S.R. items.
Note:- The item or items of the S.S.R. on which a rate is
based shall be stated in the analysis or make up
of the rate.

1-11-1 ,l ,l vkj dh vuq:i enksa ij vk/kkfjr vkuqikfrd ;k


;Fkkuqikr njsa
1 leku ewY; dh ,d lh oLrq,s a% ;fn ,l ,l vkj esa
vuq:i ensa bu oLrqvksa ds fy, gSa rFkk@;k leku
iz d kj dh o cjkcj ew Y ; dh dk;Z dq kyrk gS rc
,s l h enks a ds cjkcj dh njks a ij ns ; gks x kA
2 ewY; esa fHkUurk okyh leku ens a % ;fn ,l ,l vkj
es a oLrq v ks a rFkk@;k dk;Z d q kyrk dh ln` ; ens a gS a
fdUrq fooj.k o ewY; fHkUurk gS rc enksa dh fofHkUurk
ij vk/kkfjr lakksf/kr ewY; ftu dk fu/kkZj.k ,l ,l
vkj dh enks a rFkk ubZ enks a nks u ks a ds fy, leku
vk/kkj ij gks x k ;k tgka ,l ,l vkj dh enks a ls
;Fkkuq i kr ls iz k Ir njs a lh/kh ykxw gS a A

1.11.1.1 Any percentage applicable to S.S.R. rates shall


equally apply to the proportional rates also.

1-11-1-1 ,l ,l vkj dh njksa ij ykxw dksbZ Hkh izfrkr leku:i


ls vuqikfrr njksa ij Hkh ykxw gksaxhA

1.11.2

1-11-2 fpfUgr LVkj njs a


tc mij dh dksbZ ifr ykxw u gksrh gks rFkk ewY; eq[;:i
ls fd;s x;s Je ds O;; ij vk/kkfjr djuk gks rFkk lkexzh
dk ewY; Hkh kkfey gks rks ns; njsa Bsds dh krksZ ds vuqlkj
fufpr dh tk;saxhA

StarRates
Where none of the foregoing methods is applicable
and prices have necessarily to be based on the amount
of labour expended and the value of materials
incorporated, the rates to be paid shall be fixed in
accordance with the conditions of the contract.

uks V % ,l ,l vkj dh en ;k ensa ftu ij nj vk/kkfjr gksxh mldk


foysk.k djus ;k nj cukus esa mYys[k fd;k tk;sxkA

11

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
Notes:- (1) Rates so fixed shall be termed as Star Rates
and shall be shown as net
(2) The Contractor shall on demand produce to
the GE all such original receipted priced
vouchers, muster rolls, time sheets, and other
documents as, in the opinion of the G.E. are
necessary for the proper assessment of the
rates. In cases where the rates are based on
muster rolls and time sheets, these
documents should be put up to the EIC on
the very day the labour is engaged, for his
check and signature to certify to that effect.

uks V %

1 bl izdkj ls fu/kkZfjr dh xbZ njksa dks fpfUgr njsa dgk


tk;sxk rFkk mUgsa fokq nkkZ;k tk;sxkA
2 ftKklk djus ij Bsdns kj og lc ,slh udn Hkqxrku dh
xbZ ewy jlhns]a ukekoyh iath eLV jksy le; lkfjdk
o vU; nLrkost nqxZ vfHk;ark dks izLRkqr djsXkk ftudk
nqXkZ vfHk;Urk dks lk{; :i esa njsa fufpr djus ds fy,
vko;drk gSA ,sls ekeyksa esa tgka njsas ukekoyh iath o
le; lkfjdk ij vk/kkfjr gksa rks Bsdns kj ;g nLrkost]
izHkkjh vfHk;Urk dks mlh fnu ftl fnu Jfed dk;Z ij
yxk;s Xk, gkas muds }kjk tkap rFkk rF; izekf.kr djus
ds fy;s] gLrk{kj gsrq nsXkkA

1.12 Rates:The rate against each item is expressed in Rupees


and paise. The last two figures in rates column
indicate paise. At places, the decimal point before
these two figures may not be legible or may have
not been printed or blurred. In such event the
decimal point shall be deemed to be inserted before
last two figures of paise and rate read accordingly.

1-12 njsa %&


izR;sd en dh njsa :i;s vkSj iSlksa esa nkkZ;h xbZ gSaA njksa ds
[kkus esa vfUre nks vad iSlksa dks nkkZras gSAa dqN LFkkuksa ij bu
nks vadksa ls igys nkeyo fcUnq LiV u gks ;k Nik u gks
;k vLiV gks] ,slh nkk esa iSlksa ds vfUre nks vadksa ls igys
nkeyo yxk gqvk ekuk tk;sxk rFkk njsa mlh vuqlkj i<+h
tk;sxhA

1.13 Full Provision:The rates throughout this Schedule shall be deemed


to include every allowance necessary, without extra
measurement or charge, for meeting the
requirements of the various component parts of the
S.S.R (viz., specifications, special conditions,
preambles, item rates, etc., which shall be read together), and any or all of the following unless
specifically provided for to the contrary :
1.
Compliance with all the conditions of the contract
(including any Schedule, Specification, Drawing, etc.)
2.
Complete Work (Except to the extent specifically
excluded from the item). All labour, materials, tools
and plant, equipment, scaffolding and transport
which may be required in preparation for, and for
and in the full and entire execution and completion
of the works; including waste on materials, carriage
and cartage, carrying in, return of empties, hoisting,
setting, fitting and fixing in position.
3
Local Conditions:- Nature of the works, local facilities
for supply of labour and materials, accessibility of
site, and all other matters affecting the execution
and completion of the works.
4
Duties, etc- Payment of any octroi, terminal or sales
tax, excise and other duties on materials obtained
for the works, and any dues in respect of patent rights.
5.
Supervision:- Competent supervision of the work.
6.
Labour:- Reasonable terms and conditions of
employment, liability to pay compensation wages,
etc., as per statutory enactments, temporary
accommodation, sanitation, etc.

1-13 laiw.kZ O;oLFkk %&


bl lewph vuqlwph dh njksa eas] ,l ,l vkj ds fofHkUu
?kVd Hkkxksa dh vis{kkvksa dh iwfkZ gsrq tSls fofunsZkksa] foksk
krksZ] njksa dh izLrkoukvksa] enksa dh njksa vkfn] ftUgsa ,d
lkFk i<+k tk;sxk fcuk fdlh vfrfjDr eki ;k izHkkj ds
lHkh visf{kr NwVksa dks rFkk dksbZ ;k lHkh fuEufyf[kr dks
kkfey le>k tk;sxk tc rd fd foksk:i ls blds
foijhr O;oLFkk u dh xbZ gks%
1 fufonk dh lHkh krksZa dk vuqikyu djuk dksbZ vuqlwph]
fofunsZk] uDks vkfn lfgr
2 lai.w kZ dk;Z%& flok; ml lhek rd tks foksk :i ls en esa ls
fudky fn;s x;s gSa lHkh Je] lkexzh] vkStkj o la;=
a ] midj.k]
eapku rFkk ifjogu tks rS;kjh djus iw.kZ rFkk lai.w kZ dk;Z laiknu
ds fy, visf{kr gks ldrs gSa] lkexzh dh Nhtu] ogu o <qykbZ]
ykuk] [kkyh ik=ksa dh okilh] mBkuk] fLFkj djuk] tM+uk o
LFkkiu esa yxkukA
3 LFkkuh; fLFkfr;kn%& dk;ksZa dk Lo:i] Jfed o lkexzh dh
LFkkuh; lqfo/kk;sa LFkku dh miyC/krk] rFkk dk;Z ds laiknu ,oa
laiwfkZ dks izHkkfor djus okys vU; fok;A
4 dj vkfn %& fdlh rjg dh pqaxh] lhekkqYd] ;k fch dj]
mRikn dj rFkk dk;ksZ ds fy, izkIRk lkeXkzh ij vU; dj rFkk
izekf.kd vf/kdkj ls lacfU/kr dksbZ ns; jkfkA
5 i;Zos{k.k%& dk;Z dk i;kZIr i;Zos{k.k A
6 Jfed%& jkstxkj dh mfpr krsZa rFkk fLFkfr vuqxzg jkfk dh
vkfn dh oS/kkfud O;oLFkkvksa ds vuqlkj vLFkkbZ fuokl] lQkbZ
vkfn dh ftEesnkjh A mRikn dj rFkk dk;ksZa ds fy, izkIr
lkexzh ij vU; djA

12

7.
8.

9.

10.

11.
12.

13.
14.

15.

16.

17.

18.

19.

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
Water:- Provision of all water required including 7 ty%& visf{kr ty dh] vLFkkbZ uy o la;kstu lfgr lHkh
temporary plumbing and connections.
O;oLFkk djukA
Temporary Workshops, stores, office, labour camps,
8
vLFkkbZ dk;Zkkyk] Hk.Mkj.k] dk;kZy;] Jfed oLrh vkfn%&
etc.:- Provision of all such structures required for
dk;ksZ dks dqkyrk iwoZd lEiUu djkus ds fy, lHkh visf{kr
efficient execution of the works, and removing of
<kapksa dk fuekZ.k djuk rFkk dk;Z dh laifw kZ ds ipkr vLFkku
structures, etc. and cleaning up site on completion
of work.
ls gVkuk o lQkbZ djukA
Precautions against risks:- Precautions to prevent loss 9 tksf[keksa ds fy, iwoZ izCkU/k %& fdlh ;k lHkh tksf[keksa ds cpko
or damage from all or any risk, insurance of
ds fy, iwoZ O;oLFkk djukA vLFkkbZ vkokflr ljdkjh Hkou dk
Government building temporarily occupied,
chek djuk rFkk pkSdhnkj o jkskuh vkfn dk izcU/k djukA
provision of watchman, lighting, etc.
uksfVl] Qhl vkfn %& dk;ksZ ls izHkkfor] LFkkuh;] izkklu
10
Notices, fees, etc.:- Compliance with statutory
provisions or regulations and or bye-laws of any
rFkk@vFkok dksbZ tu lsok dEiuh ;k izkklu ds lkafo/kkfud
local authority and/or any public service company
O;oLFkkvksa ;k fofu;ekssa vkSj ;k mifof/kvksa dk ikyu djukA

or authority, affected by the works.


Setting out the works:-.Including all apparatus required.
Site drainage:- Removal of all water that may
accumulate on the site during the progress of the
works, or in trenches and excavations.
Execution of work in a workman like manner,
facilities for inspection, etc.
Rectification of bad work:- Rectification or removal
and reconstruction of any work which (as decided
by the GE) has been executed with unsound or
imperfect material or unskillful worksmanship or
of a quality inferior to that contracted for, whether
during construction or reconstruction or prior to
the expiry of the defects liability period.
Responsibility for damage and loss for all buildings,
materials, etc. at the site until handed over, other
than the accepted risks.
Removal of Rubbish:(1) Removal by the contractor off MD premises, of
any rubbish and debris and cleaning of any dirt
which may result from the execution of the work.
(2) Rubbish accumulated inside buildings shall
be removed in a clean manner either by
basketing out or lowering by tackle and not by
throwing.
(3) The decision of the GE as to what constitutes
rubbish shall be final, conclusive and
binding on the contractor.
Cleaning site and works:- Removal by the contractor,
off the Site, of any tools, plant, equipment and
materials and leaving the building, structure or
work and site in a neat, clean and presentable
condition, to the satisfaction of the EIC.
Completion:- Completing the works to the satisfaction
of the EIC, on or before the date of completion and
obtaining completion certificate from GE.
Difficult position:- Accessibility or otherwise of site,
easy or difficult positions in works, not exceeding
four storeys high or any depth not exceeding 15 m
below ground level.

11 dk;ksZ dks O;ofLFkr djuk%& visf{kr lHkh la;a=ksa lfgrA


12 vLFkku dh ukyh iz.kkyh%& dk;Z ds nkSjku vkLFkku ij [kkbZ;ksa
;k [kqnkb;ksa esa tek gq, reke ikuh dh fudklh djkukA
13 ,d lqlaLd`r dk;Zoku O;fDr ds leku dk;Z dk fuLiknu
djuk o fujh{k.k vkfn dh lqfo/kk dk izcU/k djukA
14 ?kfV;k dk;Z dk lq/kkj djuk%& dksbZ Hkh ,slk dk;Z ftles]a fuekZ.k ;k
iqu% fuekZ.k ds nkSjku ;k nksk fuokj.k ds mkjnkf;Ro dh vof/k
lekfIr ls iwo]Z irk pyrk gS fd dk;Z dks nkskiw.kZ ;k v/kwjh lkexzh
;k vdqky dkjhxjh ;k lkafofnr ls ?kfV;k xq.koRRkk ls fuikfnr
fd;k x;k gS rks nqxZ vfHk;Urk ds fu.kZ; ds vuqlkj mldk lq/kkj
djuk] ;k gVkuk vFkok iqu% fuekZ.k djukA
15 vkLFkku ds lHkh Hkouksa lkefxz;ksa vkfn dh VwV&QwV rFkk pksjh
tkus dh ftEesnkjh Bsdsnkj dh rc rd gksxh tc rd fd
mldk gLrkaRkj.k ugha gksrkA
16 dwM+k djdV gVkuk%&
1 fdlh Hkh izdkj ds dwM+k djdV ;k eyos dks ljdkjh
ifjf/k ls Bsdsnkj }kjk gVkuk rFkk dk;Z fuLiknu ls
mRiUu /kwy dks lkQ djukA
2 Hkouksa ds vUnj tek gqbZ /kwy dks LoPN rjhds ls ;k rks
Vksdjh mBkdj ckgj ys tkdj ;k ;a= }kjk mBkdj lkQ
djuk ckgj QSad dj ughaA
3 dwM+k djdV esa D;k&D;k vkrk gS bl fok; esa nqxZ
vfHk;Urk dk fu.kZ; vafre] fu.kkZ;d o Bsdsnkj ij ck/;
gksxkA
17 vkLFkku o dk;ksZ dh LoPNrk%& Bsdsnkj }kjk vkLFkku ls
vkStkj la;=
a ] midj.k o lkexzh gVkuk rFkk Hkouks]a fuek.kksa ;k
dk;Z o vkLFkku dks izHkkjh vfHk;ark dh larq Vh ds vuqlkj lkQ
LoPN rFkk ns[kus ;ksX; djukA
18 dk;Z dh liawfkZ%& dk;Z dks] dk;Z vof/k ;k mlls igys gh
izHkkjh vfHk;Urk dh larqVh ds vuqlkj iwjk djuk rFkk nqxZ
vfHk;Urk ls izek.ki= izkIr djukA
19 dfBu fLFkfr%& vkLFkku dh xH;rk ;k vU;Fkk dk;ksZ esa vklku
;k dfBu fLFkfr] pkj eaftyksa ls vuf/kd aph ;k fdlh apkbZ
esa Hkwfery ls 15 eh- ls vf/kd ughaA

13

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
Note:- Mumty or Antia (Stair cover), parapet walls, water
storage tanks and other similar constructions shall
be considered as a part of the storey over which
these are constructed and not a separate storey.
20.
Errors:- Rectification of all errors to the satisfaction
of the GE (e.g., when excavations are carried out
deeper than ordered or required, the level shall be
made up as specified).
21.
Manufacturer's instructions:- Compliance with
Manufacturer's instructions, etc., in connection
with the use of proprietary articles.
22.
Measurement:- Any contingencies (advantageous
or disadvantageous) involved in the method of
measurement herein set forth.
23.
Curved work, etc.:- Work of any quantity, size or
shape, whether level, inclined, curved battered, etc.
24.
Wastes, etc.:- All waste, laps, seams, joints, cutting
(rough or fair), straight raking or circular and
making good.
25.
Profit on M.D. Stores:- Any assumed loss or profit
to the contractor on articles or materials supplied
by the MES.
1.14 Extra Allowances on net measured work executed
in water, liquid mud or foul positions or in tidal
conditions or in buildings exceeding four storeys
high, and in RCC Overhead Reservoirs:-

uks V % eerh ;k vUrh lh<+h vkoj.k] eqMjs dh nhokjs]a ikuh Hkjus dh


Vafd;k rFkk blh izdkj ds leku fuekZ.k dks ml eafty dk
Hkkx le>k tk;sxk ftl ij ;g lc cus gS]a bUgsa izFkd eafty
ugha ekuk tk;sxkA
20 vkqf);k,a %&lHkh v'kqf};ksa dk nqxZ vfHk;Urk dh larq Vh ds vuqlkj
kks/ku djukA tc [kqnkbZ vknsfkr ;k visf{kr xgjkbZ ls vf/kd
dh tkrh gS rks xgjkbZ dks fufnZV Lrj ij yk;k tk;sxkA
21 fuekZrk ds vuqnsk %& LokfeRo lqjf{kr oLrqvksa ds iz;ksx ds
fok; esa fuekZrk ds vuqnskksa dk ikyu djukA
22 eki%& eki dh i+fr esa lfEefyr ykHknk;d ;k vykHkdkjh
fdlh Hkh laHkkouk dks ;gka izdV fd;k x;k gSA
23 o dk;Z vkfn%& fdlh Hkh ek=k] uki ;k vkdkj ds dk;Z
lery] >qdkch] o] VsMs esMs vkfnA
24 Nhtu vkfn%& lc NhtuZ] deh] Vkads] tksM+ dkV eksVs ;k
irys lh/kh ;k xksy rqM+kbZ rFkk mls Bhd djukA
25 ,e Mh lkeku ij ykHk%& ,e bZ ,l }kjk vkiwfkZ ds lkeku ;k
lkexzh ij Bsdsnkj dks dksbZ laHkkfor ykHk ;k gkfuA
1 -14 vfrfjDr ,sls fo'kq ekis x;s dk;ksZ ij ftUgsa ikuh]
dhpM+ ;k xans LFkkuksa ;k TokjHkkVs dh fLFkfr;ksa esa ;k
pkj eafty ls vf/kd ds Hkouksa esa rFkk lhesVa dahV ls
pkabZ ij fLFkfr LFkku ij fu"ikfnr fd;k x;k gksA
1-14-1 ,l ,l vkj dh njksa esa] tc rd fd foksk :i ls of.kZr
u gks( ikuh] dhpM+ xans LFkkukssa] Tokj HkkVs dh fLFkfr;ksa esa fd, x;s
dk;Z kkfey ugha gSaA tgka ekiu dk;Z ,slh ifjfLFkfr;ksa esa djokuk
vko;d gks rFkk ,slh ifjfLFkfr;ksa ds dk;Z ,l ,l vkj dh njksa esa
kkfey ugha gSa rks nh tkus okyh njsa og gksx
a h fTkUgsa ,l ,l vkj dh
njksa esa uhps fn;s x;s mi;qDr vadks ls xq.kk djds cuk;k tk;sxk%&

1.14.1 The rates in the S.S.R. do not, unless specifically


stated, include for working in water, liquid mud,
foul positions, or tidal conditions. Where measured
work has necessarily to be executed in such
conditions, and working in such conditions is not
included in the S.S.R., the rates to be paid shall be,
rates in the S.S.R. multiplied by the appropriate
figure given below:
Rates in the SSR
multiplied by

,l ,l vkj dh njksa dks blls


xq.kk djsa
(a)
(b)
(c)
(d)

Work in water or liquid mud

Work in foul position

Work interrupted by tides


Work in water or liquid mud and

interrupted by tides

A
1.25
1.33
1.50

B
1.10
1.13
1.17

1.75

1.25

Notes(a) The extra allowance for work in water or


liquid mud vide (a) above shall not apply to
excavations and earthwork. For bailing out
and pumping of water refer clause 3.7 (c) and
3.11

uks V

d ikuh ;k dhpM+ esa dk;Z


[k xanys LFkkukssa esa dk;Z
x Tokj HkkVs ls izHkkfor dk;Z
?k ikuh ;k dhpM+ rFkk TokjHkkVs ls izHkkfor
dk;Z

d ij d ds vUrxZr ikuh ;k dhpM+ dk;Z ij nh xbZ


vfrfjDr NwV [kqnkbZ djus o Hkwfe dk;Z ij ykxw ugha
gksxkA ikuh dks ckgj myhpus rFkk iEi ls ckgj
fudkyus ds fy, 3-7 x o 3-11 ls lanHkZ ysaA

14

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
(b) The multiplier in column "A" shall be used
for measured work which is entirely labour
or where labour is the predominating factor
such as Labour only Except Materials
or Fixing only.
(c) The multiplier in column "B" shall be used
for measured work requiring labour and
materials except that where the articles to be
fixed are mostly fabricated (or pre-cast) before
being placed in position, the articles shall be
paid for at Supplied only rates without any
addition, and fixing shall be paid for at
Fixing only rates multiplied by the
appropriate multiplier in column A.

[k dkye ^,* ds xq.kd dk iz;ksx ,sls ekiu dk;Z ds fy,


fd;k tk;sxk ftlessa Je iw.kZ#i ls iz/kku va'k ds :i
esas gksa tSl]s ^^dsoy Je** ^^lkexzh jfgr** ;k ^^dsoy
LFkkiu** esAa
x dkye ^^ch** dk iz;ksx ,sls ekih; dk;Z ds fy, gksxk
ftlesas ^^Je o lkexzh** dh vko';drk gks flok; mlds
tgka yxk;s tkus okyh oLrq,a vf/kdrj yxkus ls iwoZ
lajfpr ;k iwoZ jfpr gksa ogka oLrqvksa dk Hkqxrku ^^dsoy
vkiwfrZ** dh njksa esa fcuk dqN vfrfjDr fn;s gksxk rFkk
LFkkiu dk Hkqxrku ^^dsoy LFkkiu** dks dkye ^,* esa fn;s
Xk;s mi;qDr xq.kd ls xq.kk djds gksxkA

1.14.1.1 The enhanced rates are inclusive of allowance for:


(a) Loss of materials, tools and plant or
reinstatement of damage in connection with
such work;
(b) Any extra pay to which workmen are entitled
when working in the positions described, and
for the provision of water-tight boots or any
special clothing and equipment, and boathire when required; and
(c) Idle labour caused by interruptions due to
working in the positions described.

1-14-1-1 c<+h gqbZ njksa esa fuEu ds fy, NwV 'kkfey gSa%&
d lkexzh] vkStkj o la;= dk [kksuk ;k ,slh gh gkfu dk
,sls dk;ksZ ds lacU/k esa iqufuZ;kstu
[k tc dgh xbZ voLFkkvksa esa Jfed dk;Z dj jgsa gksas
rks og vfrfjDr osru ds gdnkj gSa rFkk tyjks/kd
twrs ;k fo'ks"k diM+s o lalk/ku rFkk ;fn vko';d
gks rks fdjk;s dh uko ysus ds Hkh gdnkj gksaxs] vkSj
x of.kZr fLFkfr;ksa esa :dkoV vkus ds dkj.k [kkyh cSBs
JfedA

1.14.2

1-14-2 pkj eafty ls vf/kd ds Hkou fuek.kZ dk;Z ij ,l ,l vkj


esa nh xbZ lHkh [kaMksa dh njkas esa] uhps nh xbZ izfr'kr ds
vuqlkj o`f) dh tk;sxh%&
d ikap ls vkB eafty rd ds Hkkx ds fy;s ------------ 5%

1.14.3

For pricing building work more than four storeys


high, the rates in all sections of S.S.R. shall be
increased by the percentages given below:
(a) Portion of building from five to eight storeys
..................................................................... 5%
(b) Portion of building from nine to twelve
storeys ....................................................... 10%
(c) Portion of building from thirteen to sixteen
storey ......................................................... 15%
In the case of structures other than R.C.C. overhead
reservoirs and R.C.C. Tower like structures which
have no storeys as such, the rates in all sections of
S.S.R. shall be increased by 5 percent for the part of
the structures exceeding 10 metres height from the
average ground level but not exceeding 20 metres
height. For heights exceeding 20 metres the rates
shall be further increased by 5% for every 5 metres
or part thereof, of height exceeding 20 metres.
RC.C. Overhead Reservoirs and R.C.C. Tower
like Structure
(a) For pricing work in R.C.C. Overhead
Reservoirs and R.C.C. Tower like Structure
the relevant rates for concrete work, form
work, and steel reinforcement shall be
in- creased by 40% for height exc. 7.5 m but

[k ukS ls ckjg eafty rd ds Hkkx ds fy;s --------- 10%


x rsjg ls lksyg eafty rd ds Hkkx ds fy; ---- 15%
izofry lhesasV dahV ds cus f'kjksijh tyk'k;] ehukjksa o
leku dk;ksZ ftuesa eaftysa ugha gksrh dks NksM+ dj muesa
Hkwfery ls 10 ehVj ls vf/kd fdUrq 20 eh- ls vuf/kd ds
Hkkx ds fy, ,l ,l vkj ds lHkh [kaMksa dh njksa esa 5 izfr'kr
dh o`f) dh tk;sxhA 20 eh- ls vf/kd dh WpkbZ ds fy,
izR;sd 5 eh- ;k mlds Hkkx ds fy, vfrfjDr 5 izfr'kr
dh o`f) gksxhA
1-14-3 izofyr lhesaV dahV ds f'kjksijh tyk'k; rFkk
ehukj tSls <kaps
d izofyr lhesaV ds f'kjksijh tyk'k; rFkk ehukj tSls
<kapksa ds dk;Z ds ewY; fu/kkZj.k ds fy, lacfa /kr dahV
dk;Z QekZcUnh rFkk bLikr izoyu dh njksa es]a 7-5 ehls vf/kd o 15 eh- ls vuf/kd pkabZ ds fy;s 40 izfr'kr

15

SECTION 1

SECTION 1 GENERAL RULES


[k.M 1 lkekU; fu;e
not exceeding 15 metres. For reservoirs
exceeding this height (15 m), the rates shall be
further increased by 10% for every 3 metres or
part thereof of height in excess of 15 m. e.g. the
relevant rates shall be increased by 50 percent
for the portion of reservoir between 15 m. and
18 m in height and by 60 per cent for the portion
between 18 m and 21 m in height.
(b) This increase shall apply to work in
superstructure only and shall not apply to
pipes, hand rails, ladders or other auxiliary
items connected therewith, which shall be in
creased by 5 percent if fixed above first 15 m
height from the average ground level, but not
exceeding 30 m height.
(c) For the purpose of reckoning the height of
overhead reservoirs, overall height shall be
measured from average ground level upto the
top most point of upper slab or dome of the roof.
Note1.
Water storage tanks on the roof of a building
will be priced as part of the building and
not as R.C.C. overhead reservoir.

x f'kjksifj tyk'k;ksa dh apkbZ tkuus ds fy,] vkSlr


Hkwfery ls lcls ij dh ifV;k ;k Nr ds xqEcn
rd laiw.kZ eki dh tk;sxhA
uks V

1 - Hkou dh Nr ij cuh Va f d;ks a dk ew Y ;


fu/kkZj.k Hkou ds ,d Hkkx ds :i esa fd;k
tk;sxk u fd f'kjksifj tyk'k; ds leku
2 - Hkwfery ls 7-5 eh- rd dh apkbZ ds fy, ij
d eas nh xbZ njksa esa dksbZ o`f) ugha gksxhA

1-15

d`f=e izdk'k%& tgka dgha Hkh ,l ,l vkj ds varxZr


fdlh izdkj ds dk;Z d`f=e izdk'k ls izfrikfnr djus dh
vko';drk gS rFkk ,slk djus ds fy;s izHkkjh vfHk;ark us
vkKk nh gS rks Bsdsnkj dks lafonk nj ds vfrfjDr dsoy
izdk'k dh ykxr dk Hkqxrku gksxkA Bsdsnkj ds dkj[kkus
;k ,l bZ ,l }kjk fdjk;s ij fn;s x;s Hkou esa fd;s x;s
dk;Z ;k tc Bsdns kj Lo;a dke dks xfr nsus ds fy, d`f=e
izdk'k esa dke djuk pkgs rks ;g ykxw ugha gksxkA

2.

1.15.

No increase in rates shall be allowed as per


para (a) above upto 7.5 metres height from
ground level.
Artificial light.Whenever it may be necessary
to perform work, of any description, under the
S.S.R. by artificial light, and if this is specially
ordered by the EIC, the Contractor shall be
allowed the cost of the light only in addition to
the contract rates. This shall not apply in the case
of work executed in the contractors workshops
or buildings hired to him by the M.E.S. or when
the Contractor himself wants to do work with
artificial light to speed up the work.

dh o`f) dh tk;sxhA bl 15 eh0] apkbZ ls vf/kd


ds tyk'k;ksa ds fy,] 15 eh- ls vf/kd apkbZ ij
izR;sd 3 eh- ;k mlds Hkkx ds fy, 10 izfr'kr dh
vfrfjDr o`f) dh tk;sxh vFkkZr 15 ls 18 eh- dh
apkbZ okys tyk'k;ksa ds fy, 50 izfr'kr dh rFkk 18
ls 21 eh- dh chp dh dahV okys tyk'k;ksa ds fy,
60 izfr'kr dh o`f) dh tk;sxhA
[k ;g c<+krs jh dsoy vf/kjpuk ij ykxw gksxh rFkk uyks]a
gLr iV~Vh] lhf<+;ksa rFkk vU; lgk;d oLrqvksa ij
ugha] muds fy;s 5 izfr'kr dh o`f) dh tk;sxh ;fn
og Hkwfery ls 15 eh- ls vf/kd o 30 eh- ls vuf/kd
aPkkbZ ij yxh gSaA

16

SECTION 2

SECTION 2 LABOUR RATE


[k.M 2 Je dh njsa
(a) The rates given in this Section do not bear any relation
to the minimum fair wages as promulgated by
Central/State Government or Union territories etc.
from time to time and shall apply only for the
preparation of Proportional Rates.
In the compilation of Proportional Rates, the labour
rates to be paid shall refer to the class of work
performed and not to the person employed. The labour
portion of proportional rates must bear a fair relation
to the allowances in the Labour only items of similar
work in the S.S.R.
(b) The rates of skilled and semi-skilled labour are
inclusive of all necessary tools which are normally
carried by them according to the trade practice in the
locality.

RATES PER DAY OF 8 WORKING HOURS


UNSKILLED

d bl [kaM esa nh xbZ njksa dk dsUnzh;@jkT; ljdkjksa ;k la?kh;


jkT;ksa }kjk le;&le; ij ?kksf"kr fuEure mfpr osru ls
fdlh izdkj dk lEcU?k ugha gS rFkk dsoy vkuqikfrd njsa
rS;kj djus ds fy;s ykxw gksaxhA
vkuqikfrd njksa ds ladyu esa nh tkus okyh Je dh njsa fd;s
x;s dk;Z ds oxZ dk vkjksi.k djsaxh u fd fu;qDr O;fDr dkA
vkuqikfrd njksa ds Je va'k dk] ,l ,l vkj dh leku dk;Z
dh dsoy Je dh enksa dh NwV ls ?kfu"B lEcU/k gksuk
pkfg,A
[k d'kqy o v/kZdq'ky Jfedksa dh njksa esa os lHkh vko';d vkStkj
'kkfey gSa tks ml bykds dh O;olkf;d izo`fr ds vuqlkj og
lkekU;r% j[krs gSaA

Rs.

1.

Bhisty, including mussack

169.00

2.

Chowkidar (24 hours duty)

169.00

3.

Mate (1 for 10 mazdoors)

169.00

4.

Mazdoor-boy (not less than 15 years and


under 18 years)

5.

169.00

Mazdoor-man, 18-years and above (Grass


Cutter, Mali, stone breaker, Driver for
donkeys (1 for 10 donkeys), mules, camels
(1 for 10 donkeys mules camels (1 for 3

mules or camels)

169.00

6.

Mazdoor-woman (18 years and above)

169.00

7.

Sweeper

169.00

192.00

814
SEMI-SKILLED
15.

Bellow boys, Carpenter boy

16.

Cleaner (Mechanical plant and mechanical


transport)

192.00

17.

Fireman (Static or mobile machinery)

192.00

18.

Floor Polisher (stone or terrazzo)

192.00

19.

Glazier

192.00

20.

Hammerman

192.00

21.

Lime washer

192.00

vkB ?kUVs ds dk;Z fnol dh njsa


vdq ' ky
1- e'kd lfgr fHkLrh
2- pkSdhnkj 24 ?kaVs dk dk;Z
3- esV 10 Jfedksa ij ,d
4- Jfed yM+dk 15 o"kZ ls de dk u gks rFkk 18 o"kZ
ds vUnj gks
5- Jfed iq:"k] 18 o"kZ ;k vf/kd ?kkl dkVus okyk]
ekyh] iRFkj rksMu+ s okyk] x/kksa 10 x/kksa ij 1 [kPpjks]a
V 3 [kPpjksa ;k WVksa ij 1 dks gkadus okyk

6- Jfed efgyk 18 o"kZ ;k vf/kd


7- lQkbZ okyk
8-& 14
v/kZ d q ' ky
15- /kkSaduh pykus okyk yM+dk] c<+bZ yM+dk
16- dyhuj ;kaf=dh la;a= o ;kaf=d okgu lkQ djus
okyk
17- Qk;jesu fLFfjr ;k pyrs fQjrs ;a= lk/ku
18- Q'kZ ikfy'k djus okyk iRFkj ;k VjStks
19- 'kh'kk yxkus okyk
20- gFkkSM+k pykus okyk
21- pwuk /kksus okyk

17

SECTION 2

SECTION 2 LABOUR RATE Contd...


[k.M 2 Je dh njsa& tkjh--SEMI-SKILLED Contd...

Rs.

22.

Operator (Pneumatic tools)

192.00

23.

Painter (ordinary)

192.00

24.

Pump-Attendant

192.00

25.

Quarryman

192.00

26.

Roof tiler, thatcher

192.00

27.

Sawyer

192.00

28.

Well sinker

192.00

29.

Tar/bitumen sprayer

192.00

192.00

30 36
37.

Blacksmith, tinsmith

v?kZ dq ' ky& tkjh--22- pkyd ok;q ls pyus okys vkStkj


23- jaxlkt lk/kkj.k
24- iEi pykus okyk
25- [knku Jfed
26- Nr esa [kIij] QWwl Nkus okyk
27- vkjh pykus okyk
28- dqvka [kqnkbZ djus okyk
29- dksyrkj@rkjdksy QSykus okyk
30-&36
37- yksgkj] dybZdkj
dq ' ky

SKILLED
38.

Boiler attendant

39.

Bricklayer, pavior, floor or wall tiler

225.00

40.

Cable jointer

248.00

41.

Carpenter, joiner

225.00

42.

Plasterer

225.00

43.

Driver (Mechanical transport)

248.00

44.

Driver (Engine static)

248.00

45.

Driver (Road roller, compressor, concrete

mixer, crusher and the like)

248.00

46.

Fitter (Structural or pipe)

225.00

47.

Lineman

225.00

48.

Mason (stone mason)

225.00

49.

Painter (skilled), polisher

225.00

50.

Plumber, drainlayer

225.00

51.

Signwriter

248.00

52.

Turner (Metal)

248.00

53.

Welder

248.00

54.

Wireman/electrician

225.00

55 75

248.00

38- HkV~Vh ok;yj pkyd


39- bZV] iRFkj fCkNkbZ] Q'kZ cukus okyk ;k nhokj
ij Vkby yxkus okyk
40- dscy tksM+us okyk
41- c<+bZ] la;kstd
42- iyLrj djus okyk
43- pkyd ;kaf=d okgu
44- pkyd fLFkj batu
45- pkyd jksyj] dEiz'S kj] dahV feykok] 'kj rFkk
leku
46- fQVj lajpuk ;k uy
47- ykbu eSu
48- jkt iRFkj feL=h
49- jaxlkt dq'ky] ikfy'k okyk
50- uyds yxkus okyk] ukyh cukus okyk
51- fpUg fy[kus okyk
52- VuZj /kkrq
53- Vkadk cSYMj yxkus okyk
54- rkj yxkus okyk ok;jeSu fo|qrdkj
55 75

18

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
SPECIAL CONDITIONS
fo'ks"k 'krsZa
3.1

Measurement of Excavation

3-1

feh [kqnkbZ dh eki

3.1.1 The measurements shall be those of the authorised


dimensions from which soil has been taken out and
shall be measured net without allowance for
increase in bulk. Where, however, working space is
necessary such as for basement walls requiring
external treatment or where overhead working is
not practicable, an additional working space of 60
cm from each external face of the wall shall be
measured and paid for. In the case of special work
like guniting, etc. this allowance shall be suitably
increased as decided by the GE. Extra excavation
on account of slips or falls shall not be measured.

3-1-1 eki ml vf/kd`r foLrkj dh yh tk;sxh ftlesa ls feh


fudkyh xbZ gS rFkk Fkksd o`f) dh NwV fcuk] fo'kq) ekih
tk;sxhA fQj Hkh tgka dkedkth txg vko';d gS tSls uhps
dh nhokjksa dks ckgjh vipkj nsus ds fy, ;k tgka ij ls
dk;Z djuk laHko ugha gS ogka 60 lseh- izR;sd nhokj ckgjh
rjQ ls vfrfjDr dkedkth LFkku ekik tk;sxk vkSj Hkqxrku
gksxkA elkyk yxkus tSls fo'ks"k dk;ksZ ds fy, nqxZ vfHk;ark
ds fu.kZ; vuqlkj bl NwV esa mi;qDr o`f) dh tk;sxhA
f[kldus ;k fxjus ds dkj.k dh xbZ vfrfjDr [kqnkbZ ugha
ekih tk;sxhA

3.1.2 Where excavation is in trenches or from borrow pits


in fairly uniform ground, the measurement of cutting
in trenches or borrow pits shall be made. Dead men
or Tell-tales shall be left at suitable intervals to
determine the average depth of excavation.

3-1-2 tgka [kqnkbZ [kkb;ksa esa ;k Li"V le Hkwfe [krkuksa esa gks rks
[kkbZ;ksa ;k [krkuksa dh dVkbZ dh eki dh tk;sxhA **fLFkjd**
;k **fLFkfr lwpd** mi;qDr Qklys ij NksM+s tk;saxs rkfd
[kqnkbZ dh vkSlr xgjkbZ ekywe dh tk ldsA

3.1.3 Where the ground is not uniform and in case of roads,


runways, hard-standing and other large areas, where
directed, levels shall be taken before the start and after
the completion of the work and quantity of excavation
shall be computed from these levels.

3-1-3 tgka Hkwfe le ugha gS rFkk lM+dkas] gokbZ ikf;ksa] dBksj Q'kksZa
rFkk vU; fo'kky {ks=ksa ds lac/a k esa tgka funsZf'kr gks ry eki
dk;Z izkjEHk ls igys o dk;Z lekfIr ds ckn yh tk;sxh rFkk
[kqnkbZ dh ek=k ryekiksa ls ekywe dh tk;sxhA

3.1.4 Where soft disintegrated rock and hard rock are


mixed, the measurement for the total quantity shall
be made by methods described in paras 3.1.2. and/
or 3.1.3 above. The hard rock excavated shall be
stacked and measured in stack. The quantity of hard
rock excavated shall be reduced by 50% to allow for
voids. From the total quantity of the mixture the
quantity of hard rock excavated thus arrived at,
shall be deducted to work out the quantity of the
soft/disintegrated rock excavated.

3-1-4 tgka uje fo?kfVr pku o l[r pku feyoka gksa rks iwjh
ek=k dh eki ij ds iSjk 3-1-2 rFkk@vFkok 3-1-3 esa crkbZ
xbZ i)fr ds vuqlkj yh tk;sxhA [kqnkbZ esa fudyh l[r
pkuksa ds ps yxsxas o pksa esa ekiu gksxkA [kqnkbZ esa fudyh
pkuksa dh ek=k esa ls fjfDr;ksa ds fy;s 50 izfr'kr dh dVkSrh
dh tk;sxhA [kqnh l[r pku dh bl ek=k dks dqy ek=k esa
ls ?kVk;k tk;sxk vkSj bl izdkj ls uje@fo?kfVr pku dh
ek=k izkIr gks tk;sxhA

3.1.5 Where hard/dense soil, soft/disintegrated rock and


hard rock are mixed, the measurement for the total
quantity shall be made by methods described in paras
3.1.2 and/or 3.1.3. above. After removal of the
hard/dense soil, the levels of the exposed rock surface
shall be taken and the quantity of hard/dense soil
removed, worked out from the difference between the
original levels and the new levels. Where this is not
possible, the excavation shall be completed leaving
tell-tales and from the cross-section of these tell-tales,
the area of the hard/dense soil excavated, shall be
worked out and then the volume of the hard/dense
soil excavated arrived at. The quantity of hard/dense
soil shall then be deducted from the total quantity of

3-1-5 tgka l[r@la?ku feh] uje@fo?kfVr pku o l[r pku


feyoka gks rks ij ds iSjk 3-1-2 rFkk@vFkok 3-1-3 esa dgh x;h i)fr
ds vuqlkj lai.w kZ ek=k dh eki dh tk;sxhA l[r@l?ku feh gVkus ds
ckn dh pkuh lrg ds ry dh eki yh tk;sxh rFkk [kksnh xbZ
l[r@l?ku feh dh ek=k dks] vkjfEHkd ry dh eki o u;s ry dh
eki ds chp ds vUrj ls fudkyk tk;sxkA tgka ;g laHko gks ogka [kqnkbZ
dks **fLFkfr lwpd** NksMrs gq, iw.kZ fd;k tk;sxk rFkk bu **fLFkfr
**lwpdks*a * dh vuqiLz Fk dkV ls [kksnh xbZ l[r@l?ku feh ds {ks= dks
fudkyk tk;sxk vkSj fQj mldh ek=k vk;sxhA 'ks"k cph ek=k l[r
pku o uje@fo?kfVr pku dh ek=k gksxhA fQj l[r@l?ku feh
dh ek=k dks dqy [kksnh xbZ ek=k esa ls ?kVk fn;k tk;sxkA l[r pku
rFkk uje@fo?kfVr pku dh ek=k dks ij ds iSjk 3-1-4 ds vuqlkj
l[r pku ds vyx ls ps yxkdj fudkyk tk;sxkA

19

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
excavation carried out. The balance shall then be
treated as total quantity of hard rock and soft/
disintegrated rock. The quantities of hard rock and
soft/disintegrated rock shall then be worked out as in
para 3.1.4 above by stacking the hard rock separately.
3.1.6 Where soft/loose soil, hard/dense soil, soft/
disintegrated rock and hard rock are mixed, the
measurements of the entire quantity shall be made
by methods described in paras 3.1.2. and/or 3.1.3
above. The quantities of soft/loose soil and hard/
dense soil shall be worked out from the cross
sections based on deadmen or tell-tales as
mentioned in para 3.1.5 in case of hard/dense
soil. The total quantity of soft/loose and hard/
dense soil shall then be deducted from the total
excavation to arrive at the total quantity of rock
excavated. The quantities of soft/disintegrated rock
and hard rock excavated shall be worked out as in
para 3.1.4.

3-1-6 tgka uje@<hyh feh] l[r@l?ku feh] uje@fo?kfVr


pku rFkk l[r pku feyoka gksa rks lai.w kZ ek=k dh eki ij
ds iSjk 3-1-2 rFkk@vFkok 3-1-3 ds vUrxZr crkbZ xbZ fof/k ds
vuqlkj yh tk;sxhA l[r@l?ku feh ds fo"k; esa uje@<hyh
feh o l[r@l?ku feh dk ekeyk ij ds 3-1-5 esa of.kZr
fof/k ds *fLFkjd* ;k *fLFkfr lwpd* dks vk/kkj cukdj vuqiLz Fk
dkV ls fudkyk tk;sxkA uje@<hyh o l[r@l?ku feh dh
dqy ek=k dks] dqy [kksnh xbZ pku dh ek=k izkIr djus ds fy,]
la/ku [kqnkbZ esa ls ?kVk;k tk;sxkA uje@fo?kfVr pku o [kksnh
xbZ l[r pku dh ek=k] iSjk 3-1-4 ds vuqlkj fudkyh tk;sxhA

3.1.7

Trenches with grips for sockets of pipes shall


be measured the net depth exclusive of grips.

3-1-7 uy dksVj **idM+** lfgr [kkb;ksa dh **idM+ksa** dks NksM+dj


fo'kq) ekik tk;sxkA

3.1.8

Where battering or benching is ordered, the


excavation shall be measured net as ordered or as
excavated whichever is less. Battering or
benching to the sides of excavation to avoid
timbering shall have the prior approval of the GE
and in that case payment will be made for the
consequent extra excavation, or the area of
timbering required, had the sides not been battered
or benched, whichever is cheaper at the SSR rates.

3-1-8 tgka ikrd ;k iSMh dh vkKk gks rks mldh eki] tSlh vkKk gks
;k tSlh [kqnkbZ dh xbZ gks] tks Hkh de gks fo'kq) dh tk;sxhA
r[rsona h ls cpus ds fy,] [kqnkbZ dh oxyksa esa **ikrd ;k iSMh+ **
cukus dh nqxZ vfHk;Urk ls iwoZ vuqefr ysuh gksxh rFkk ml n'kk
esa mlds QyLo:i vfrfjDr [kqnkbZ vFkok visf{kr r[rsona h ds
{ks= ;fn Hkqtkvksa esa ikrd ;k iSMh+ u gksrh] tks Hkh lLrk gks mlds
fy, Hkqxrku fd;k tk;sxkA

3.1.9

All excavation shall be measured in successive


stages of 1.5 m depth stating the commencing
level. Excavation upto 1.5 m below ground level
and depositing excavated materials on the
ground are included in the items of earthwork.
Obvious lift only shall be measured i.e. lift
inherent in the lead due to ground slope shall not
be measured except for a lead upto 250 m. When
the earth has to be carried over a bank or
obstruction and deposited beyond it, the lift shall
be the difference in level between the centre of
gravity of the excavated earth and top of bank or
obstruction. This shall not apply to cases where
no lift is involved as in hill-side cutting.

3-1-9 lHkh [kqnkbZ dks izkjfEHkd ry ls 1-5 eh- dh fed voLFkk ij


ekik tk;sxkA feh dk;Z njksa esa Hkwfery ls 1-5 eh- rd dh
[kqnkbZ djus rFkk feh dks tehu ij bdV~Bk djuk 'kkfey
gSA dsoy izdV mBkbZ ekih tk;sxh vFkkZr Hkwfe ds <yku ds
dkj.k vkbZ nwjh dks 250 eh- ls vf/kd ugha ekik tk;sxkA tc
feh dks Hkjkoksa ;k vojks/kdksa esa Hkjus ds fy;s blls vf/kd nwjh
ij ys tkuk gks rks mBkbZ] [kksnh xbZ feh ds xq:Ro ds dsUnz
rFkk Hkjkoksa ;k vojks/kksa ds ij dh lrg ds chp dk vUrj
gksxhA igkM+h LFkkuksa esa dVkbZ ij tgka mBkbZ dh vko';drk
ugha gksrh ,sls ekeyksa esa ;g ykxw ugha gksxkA

3.1.10

In case of any dispute with regards to the classification of various strata and their depth the
decision of G.E. will be final and binding.

3-1-10 fofHkUu Lrj ds oxhZdj.k ds laca/k esa ;k mudh xgjkbZ ds


fo"k; esa mBs fdlh fookn ds fo"k; esa nqxZ vfHk;ark dk fu.kZ;
vafre rFkk ck/; gksxkA

20

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
3.2

Excavation in Trenches for Pipes, Cables, etc.

3-2 uyksa dscyksa vkfn ds fy;s [kkb;ksa esa [kqnkbZ dk;ZA

3.2.1

Authorised quantities or those actually excavated,


whichever are less shall be allowed.

3-2-1 vf/kd`r ek=k ;k og tks okLro esa [kksnh xbZ gS] tks Hkh de
gks ekU; gksxhA

3.2.2

For the purpose of calculating cubic contents,


cross sections shall normally be taken at suitable
intervals, i.e. at manhole or valve chamber
intervals except in abnormal cases like sudden
change in strata or undulating ground, etc., when
they may be taken at closer intervals as decided
by the EIC.
Authorised widths: Unless otherwise provided
for, authorised widths shall be as under :(a) Upto 1 m depth, the width of the trench for the
purpose of measurements of excavations, shall
be arrived at by adding 40 cm to the external
diameter of the pipe (not the sockets), cable,
conduit, etc. Where a pipe is laid on concrete
bed/cushioning layer the authorised width
shall be the external diameter of the pipe plus
40 cm, or the width of concrete bed/
cushioning layer, whichever is more.
(b) For depths exc. l m an allowance of 5 cm per
metre of depth for each side of the trench shall
be added to the authorised width (i.e. external
diameter of pipe plus 40 cm) except where
battering or benching has been ordered. This
allowance shall apply to the entire depth of
the trench. The authorised width in such case
shall, therefore, be equal to (depth of trench)/
l0 plus external dia. of pipe plus 40 cm or the
width of concrete bed/cushioning layer,
whichever is more.
(c) Where more than one pipe, cable, conduit,
etc. are laid, the diameter shall be reckoned
as the horizontal distance from outside to
outside of the outermost pipes, cables
conduits, etc.

3-2-2 ?kuRo dh x.kuk djus ds fy, vuqizLFk dkVksa dks lkekU;:i


ls mi;qDr Qklys ij fy;k tk;sxk vFkkZr~ esugksy ;k
okYoxzg ij flok; vLoHkkfod ekeyksa esa tSls Lrj esa
vpkud cnyko ;k rjafxr Hkwfe vkfn tcfd izHkkjh vfHk;ark
ds fu.kZ;kuqlkj og de Qklys ij Hkh fy;s tk ldrs gSaA

3.2.3

3-2-3 vf/kd`r pkSM+kb;kW tcfd vU;Fkk O;oLFkk u gks vf/kd`r


pkSMk+ bZ;kn fuEukuqlkj gksxhA
d 1 eh- xgjkbZ rd [kqnkbZ dh eki ds fy,] [kkb;ksa dh
pkSM+kbZ] uy ds ckgjh O;kl ldksVj ugha] dsoy] uyh
vkfn esa 40 lseh- tksM+dj vk;sxhA tc uy dks dahV
ds fcNkou@xyhpk ijr ij fcNk;k tkrk gS rks pkSMk+ bZ
uy ds ckgjh O;kl esa 40 lseh- tksM+dj gksxh ;k
dahVfcNkou@xyhpkbZ ijr tks Hkh vf/kd gksxhA
[k ,d ehVj ls vf/kd dh xgjkbZ ds fy;s] [kkbZ dh izR;sd
Hkqtk esa 5 lseh- izfr ehVj vf/kd`r pkSM+kbZ esa tksM+k
tk;sxk vFkkZr uy dk ckgjh O;kl tek 40 lseh flok;
mlds tgka ikrd ;k iSMh dh vkKk nh xbZ gksA ;g
vfrfjDr] [kkbZ dh lai.w kZ xgjkbZ ds fy;s gksxkA blfy;s
,sls ekeys esa vf/kd`r pkSM+kbZ [kkbZ dh xgjkbZ [kkbZ dh
xgjkbZ tek uy dk ckgjh O;kl tek 40 lseh- ds cjkcj
gksxh ;k dahVfcNkou@xyhpkbZ ijr dh pkSMk+ bZ tks Hkh
vf/kd gks] gksxhA
x tgka ,d ls vf/kd uy] dscy] uyh vkfn fcNh gSa rks
O;kl dks] uy] dscy] uyh vkfn ds ckgj ls ckgj
lekukUrj fudkyk tk;sxkA

3.3

Excavations for post holes in varying strata:- In


excavation for post holes through varying strata
the depth of different strata shall be recorded. The
rate for excavation in post holes of different strata
shall be worked out on an average basis according
to the depth of the different strata in one post hole.

3-3 [kaHkksa ds fy, fofHkUu Lrj ds xM~<s [kksnuk% [kaHkksa ds


fofHkUu Lrj ds xM~<ksa dh [kqnkbZ esa fofHkUu Lrjksa ij xgjkbZ dh eki
yh tk;sxhA ,d xM~<s dh fofHkUu Lrjksa ij dh xbZ eki dh vkSlr
ds vk/kkj ij njsa fuf'pr dh tk;saxhA

3.4.

Shallow Excavation:- Shallow excavations over


areas, if not exceeding 30 cm deep, shall be
measured as surface excavation. If however,
portions of the area are to be excavated to a greater
depth, the total area of such portions shall be
deducted from the overall shallow excavation
measurements and then whole depth of the

3-4 mFkyh Hkwfe dh [kqnkbZ% pkbZ oys {ks=ksa esa dh xbZ [kqnkbZ ;fn 30
lseh- ls vf/kd xgjh ugha gS rks mls lrgh [kqnkbZ ds :i esa ekik tk;sxkA
fQj Hkh ;fn mlds dqN Hkkx dh vf/kd xgjkbZ rd [kqnkbZ djuh gS] rks
,sls Hkkxksa ds dqy {ks= dks lai.w kZ [kqnkbZ dh eki es ls ?kVk fn;k tk;sxk
vkSj fQj vf/kd xgjs Hkkxksa dh mpkbZ;ksa dh [kqnkbZ dks leku ekik tk;sxk
tgka lrgh [kqnkbZ dks iwoZ d`R; funs'Z k fd;k x;k gS rks lrgh [kqnkbZ dk
lek/kku djus ds ckn mFkyh [kqnkbZ dk fu/kkZj.k gksxkA

21

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
deeper portions shall be measured as excavation
over areas. Where surface excavation has been
ordered as a prior operation, the depth of shallow
excavation shall be determined after adjusting
for the depth of surface excavation.
3.5.

Work to Existing Paving:- Relaying and making


good to paving macadam, etc. shall be measured
separately. Any damage caused shall however be
made good by the contractor at his own expense.

3-5

fo?keku dqfeu Q'kZ esa dk;Z% eSdMe Q'kZ dks iqu%


fcNkuk o Bhd djus vkfn dh eki izFkd gksxhA fdlh Hkh VwV
QwV dks Bsdsnkj vius [kpsZa ij Bhd djsxkA

3.6

Earth Filling, Embankments and Traverse, etc.:Measurements shall be those of the borrow pits,
trenches, etc. from which the material is obtained. If
this is found difficult or impracticable,
measurements of the finished embankment, traverse
of earth filling shall be taken after consolidation
and 10% deducted to allow for increase in bulk after
excavation. No deduction shall however be made
in case of consolidated fills in confined places such
as floors. Where the consolidation is done by heavy
mechanical machinery or to the specified standard
proctor density under optimum moisture
conditions, deduction shall be 5 percent.

3-6

feh HkjkbZ] Hkjko ca/k] pe vkfn% [krku xM~<ksa dh


[kkb;ksa dh gh eki gksxh tgka ls feh yh xbZ gSA ;fn ,slk
dfBu ;k laHko u gks rks HkjkbZ okys Hkjko ca/k] pe dks l?ku
djus ds ckn ekik tk;sxk rFkk [kqnkbZ ds ckn ds Fkksd esa 10
izfr'kr dh o`f) gksxhA tgka ;kaf=d e'khuksa ls Bksliu yk;k
x;k gS ;k vuqdwYkre tyka'k voLFkkvksa esa fu/kkZfjr ekud
izksDVj ?kuRo fd;k x;k gS] ogka dVkSrh 5% gksxhA

3.7

Rates
The rates for all excavation items include:
(a) Excavating either straight or curved on plan;
(b) Clearing away all grass vegetation, saplings,
shrubs, brushwood, undergrowth, roots, and
trees not exceeding 30 cm girth (measured one
metre above ground level) and removing rubbish
upto a distance of 50 metres outside the
periphery of the area under clearance except in
the case of surface dressing which includes for
all the foregoing except clearing away of trees;
(c) Bailing out, pumping out or otherwise removing
all water which may accumulate in the
excavations, from all causes other than those
described in 3.11;
(d) Setting out the work profiles, etc. as well as for
all tools and plant;
(e) All materials and labour required for fencing
in and protecting against risk of accidents, to
open excavations, etc. and for providing
gangways with handrails across open trenches,
etc. where necessary.
(f) Watching and lighting, whenever necessary.
(g) Forming (or leaving) Dead men or Tell tales
in borrow pits and their removal after record of
measurements;
(h) Forming (or leaving) steps in sides of deep
excavations and their removal or covering up,
after record of measurements;

3-7 njsa
laiw.kZ [kqnkbZ dk;Z dh enksa dh njksa esa fuEu 'kkfey gSa%&
d vk;kstu ij lh/kh ;k o [kqnkbZA
[k reke ?kkl ouLifr} >kM] >kM+h] >a[kkM+] v/k%mit]
tM+sa o 30 lseh- xksykbZ ls de ds isM+ /kjkry ls ,d
eh- ij ekiu dks lkQ djuk rFkk eyos dks lQkbZ
fd;s tkus okys {ks= dh lhek ls 50 eh- ds Qklys ij
Qsd
a uk flok; lrg dks lery djus ds dk;Z ds ftlesa
isM+ksa dks gVkus ds vykok lHkh izko/kku 'kkfey gSaA
x ikuh dks tks [kqnkbZ dk;Z esa bdk gks ldrk gS mls iEi
ls vFkok vU; rjhds ls 3-11 o.kZu ds vykok ckgj
fudkyukA
?k :ijs[kk vkfn ds lkFk&lkFk vkStkj la;a= vkfn dks
O;ofLFkr djukA
M [kqyh [kqnkbZ dks nq?kZVukvksa ds tksf[ke ls cpko ds fy,
rFkk ckM+ yxkus ds fy, lHkh visf{kr lkexzh o Jfed
vkSj tgka vko';d gks ogka [kkbZ ds vkjikj lewg ekxZ
lfgr gFk ifr;k ykxukA
p tgka dgha t:jh gks pkSdhnkjh o jks'kuh dh O;oLFkkA
N xM~<ksa ds vk;kstuksa es]a **mBkos** vFkok **lh<+h** cukuk ;k
NksMu+ k rFkk eki fy[k fy, tkus ij mUgsa nwj djukA
t xgjh [kqnkb;ksa esa lh<+h cukuk ;k NksMu+ k rFkk mUgsa eki
gksus ds ckn mBkuk ;k <dukA

22

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
(j) Excavation for insertion of planking and
strutting;
(k) Removing slips or falls in excavations;
(1) Authorised battering or benching of
excavations; and,
(m) Slinging or supporting pipes, electric cables,
etc. met with during excavation.

> r[rs canh o iqLrkoanh yxkus ds fy, [kqnkbZ djukA


= [kqnkbZ ds vUnj yq<+dh ;k fxjh feh dks gVkukA
r [kqnkbZ dh vuf/kd`r vkufrdsa ;k ikSf<+;ka gVkuk] rFkk
Fk mn~ca/ku vFkok vk/kkjh uy] fo|qr dscysa tks [kqnkbZ esa
feyh gksA

3.8

The rates for excavation items do not include


timbering or battering and/or benching of sides
in lieu of timbering. Payment will be made as in
3.1.8.

3-8

[kqnkbZ dh njksa r[rsona h] vkufrds rFkk@vFkok r[rs canh ds


LFkku ij ik'koZ ikSf<+;ka 'kkfey ugha gSaA budk Hkqxrku
3-1-8 ds vuqlkj gksxkA

3.9

Getting out:- The rates for all excavation items


include getting out, that is, placing excavated
material clear of the edge of excavation by at least
one metre or one third of the depth of excavation,
whichever is more. In special cases, where the
disposal area is limited or where the application of
this requirement is impracticable, the contractor
may be allowed a berm of reduced width, in any
case not less than one metre; provided the material
being excavated is sufficiently stable and shoring
is provided to carry the additional load.

3-9

feh ckgj fudkyuk% [kqnkbZ dh njksa esa feh dks ckgj


fudkyuk 'kkfey gS] vFkkZr~ [kksnh xbZ lkexzh dks] [kqnkbZ ds fdukjs
ls ,d ehVj nwj ;k [kqnkbZ ds cjkcj esa tks Hkh
vf/
kd gks ij Mkyuk 'kkfey gSA fo'ks"k voLFkkvksa esa tgka fuiVku dk
LFkku lhfer gks ;k tgka bl vis{kk dh iwfkZ vO;ogkfjd gks] rks
Bsdns kj dks de nwjh] ysfdu ,d ehVj ls de ugha dh de
pkSMk+ bZ ij [kqnkbZ dh lkexzh yXkkus dh vuqefr nh tk ldrh gS]
Ck'krsZ fd fudkyh gqbZ lkexzh iw.kZr% fLFkj gks rFkk vf/kd Hkkj lgu
djus ds fy, Vsd canh lgkjk dk izcU/k gksA

3.10 Removal of Spoil:- Removal of excavated material


shall be measured only when it is removed beyond
the limit specified for getting out or beyond the lead
specified in the particular item concerned. The
Contractor shall allow for any mode of haulage and
transport over roads in bad repair, or with steep
gradient or over unconsolidated ground.

3-10 Qkyr~ feh mBkuk% fudyh lkexzh dh eki rHkh dh


tk;sxh tc mls ckgj fudkyus dh lhek ;k lacfU/kr en esa
fufnZ"V nwjh ls vf/kd nwjh ij ys tkbZ xbZ gksA Bsdns kj fdlh
Hkh <qykbZ lk?ku rFkk okgu dks VwVh QwVh lM+dksa ;k x<+ksa ;k
vle jkLrs ij pyk;sxkA

3.10.1 Removal includes the separation of the useful from


the useless portion and stacking the useful material
in regular heaps and removal of the useless as
indicated.

3-10-1 gVkus esa mi;ksxh o vuqi;ksxh lkexzh dks vyx djuk rFkk
mi;ksxh lkexzh dks fu;fer <sjksa esa yxkuk rFkk vuqi;ksxh dks
crk;s vuqlkj Qsaduk 'kkfey gSA

3.11 Pumping:- If an inflow of water into excavations is


caused by powerful springs, tidal or river seepage,
broken water mains or drains and the like (other
than those broken through the Contractors
negligence) or rising of water table the Contractor
shall immediately inform the GE. If, in the opinion
of the GE the inflow is due to any of these causes, he
shall issue instruction, in writing, as to the method
to be employed in clearing the water from excavation
and additional payment shall be allowed.

3-11 iEi ls ikuh fudkyuk% ;fn [kqnkbZ esa ikuh dk cgko]


'kfDr'kkyh >juks]a TokjHkkVs ;k unh ds fjlko] VwVh ikuh dh
eq[; uy ;k ukfy;ksa ;k leku ls Bsdns kj dh vlko/kkuh ls
VwVh ds vykok ;k Hkwfe tyLrj ds ij gksus ls vk;k gS rks
Bsdsnkj rqjar nqxZ vfHk;ark dks lwfpr djsxkA ;fn nqxZ
vfHk;ark dh jk; esa cgko bu fdlh dkj.k ls mRiUu gqvk gS
rks og fyf[kr esa ikuh fudkyus dh fof/k lac/a kh vuqn's k nsxk
rFkk Bsds dh 'krksZ ds vuqlkj vfrfjDr Hkqxrku fd;k tk;sxkA

23

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
3.12 Hard Rock Blasting Prohibited:- If blasting of hard 3-12 dBksj pkuksa dks fCkLQksV ls mM+uk fu"ks/k gS%& ;fn
rock is prohibited or impracticable owing to special
dBksj pkuksa dks foLQksV ls mM+kuk euk gS vFkok LFky vkfn
condition of the site, etc., and use of mechanical
dh fo'ks"k voLFkk vkfn ds dkj.k vO;ogkfjd gS o nqxZ
plant or chisel cutting is ordered in lieu of blasting
vfHk;ark dh iwoZ fyf[kr vkKk ls rFkk foLQksV ds LFkku ij
by a prior written order of the GE, an addition of 50
;kaf=d la;=
a vFkok Nsuh dVkbZ dk vkns'k fn;k tkrk gS] rks
per cent shall be made to the corresponding
vuq
l
p
w
h
dh
lekuqdy
w nj esa 50 izfr'kr vfrfjDr ns; gksxkA
Schedule rate. This addition shall cover the
;g vfrfjDr] ok;qizpkfyr dahVds jks/kd] Nsfu;ksa] QfUUk;ksa
provision of pneumatic concrete breakers, chisels,
vkfn }kjk dk;Z laiknu dks Hkh lgstrk gSA
wedges, etc., for the execution of the work.
3.13 Serviceable Materials:- Any vegetable, earth, sand, 3-13 mi;ksxh lkexzh% dksbZ ouLifr] feh ckyw] ctjh] iRFkj bZV
gravel, stone, debris of brickwork, concrete,
dh fpukbZ dk eyok] dahVfpukbZ vkfn tks [kqnkbZ ls izkIr
masonry, etc., obtained from excavations shall
gqbZ gSa og j{kk ea=ky; dh laifk gksxhA fdlh Hkh mi;ksxh
remain the property of MD. Any useful material
lkexzh dk ;fn Bsdns kj mi;ksx djrk gS rks ekuh xbZ njksa ds
indicated for use by the Contractor shall be charged
vuqlkj Bsdsnkj ls mxkgh gksxhA
to him at the agreed rates.
SURFACE EXCAVATION

lrgh dh [kqnkbZ

PER SQUARE METRE

03001 Surface excavation n.exc


(not exceeding) 30 cm
deep and averaging 15cm
deep and getting out
03002 Add to (or deduct from)
last item for every 3 cm
or part thereof above or
below 15 cm average

depth

Soft/loo- Hard/de- Mud Soft/dis Hard


se soil
nse soil
integrated rock

izfr oxZ ehVj

ueZ@<hyh dBksj@l?ku Xkkjk ueZ@fo?k dBksj


feV`h
feV`h
fVr pV`ku pV`ku

03001 lrgh [kqnkbZ 30 lseh ls vuf/kd


vf/kd ugha o vkSlr xgjkbZ 15
Rs.
lseh rFkk ckgj fudklh

Rs.

Rs.

Rs.

Rs.

15.90

27.80

44.70

61.60

131.10

6.50

03002 fiNyh en esa tksM+sa ;k ?kVk;sa 15


lseh- dh vkSlr xgjkbZ ls de ;k
vf/kd ij izR;sd 3 lseh- de ;k

13.90
vf/kd gsrq

2.20

2.80

5.40

ROUGH EXCAVATION, EXCAVATION OVER AREAS, IN TRENCHES, ETC.

vle [kqnkbZ] mPps LFkkuksa] [kkbZ;ksa vkfn esa [kqnkbZ


(a)

(b)

(c)

(d)

(e)
(f)

Payment under item 03005 shall not be allowed


where no lift beyond 1.5 m is involved, such as
excavation in sloping ground where the excavation
is accessible from one side.
Payment under items 03005 and 03007 is applicable
for the quantity in the respective stage of
excavation, and not to the total quantity of
excavation from the commencing level.
Payment under items 03004 to 03007 shall include
for dressing/trimming sides and levelling/grading
and ramming of bottoms of excavation.
The depth for any particular length of an excavation
for the purpose of lift shall be the average depth at
two ends.
Special Condition 3.2 shall apply to excavation of
trenches for pipes, cables, etc.

d en 03005 ds vUrxrZ Hkqxrku dh vuqefr ugha gksxh tgka 1-5


eh- ls vf/kd dh nwjh vis{kk ugha gS tSls <yoka eSnkuksa esa tgka
[kqnkbZ ,d vksj ls lqxe gSA
[k en 03005 o 03007 ds vUrxrZ Hkqxrku [kqnkbZ ds lacfU/kr
pj.kksa dh ek=k ds fy;s ykxw gSa] izkjfEHkd ry ls laiw.kZ [kqnkbZ
dh ek=k ij ughaA
x en 03004 ls 03007 ds Hkqxrku esa lery djuk@ik'oks dh
dkVNkaV rFkk [kqnkbZ ds ry dks lery djuk@laHko cukuk o
dqVkbZ djuk 'kkfey gSA
?k mBkus ds iz;kstu ds fy, fdlh fo'ks"k [kqnkbZ ds fy;s xgjkbZ
gksxh nks fdukjksa dh vkSlr xgjkbZA

M fo'ks"k 'krZ 3-2] uyksa] dsoyksa vkfn ds fy, dh xbZ [kqnkbZ ij


ykxw gksx
a hA
For measurement of item 03009 Special Condition p en 03009 dh eki ds fy;s fo'ks"k 'krZ 3-6 ykxw gksxhA
3.6 shall apply.

24

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
ROUGH EXCAVATION, EXCAVATION OVER AREAS, IN TRENCHES, ETC. -Contd...
vle [kqnkbZ ps LFkkuksa [kkbZ;ksa vkfn esa [kqnkbZ tkjh--PER CUBIC METRE

Soft/loo- Hard/dese soil


nse soil

Mud

ueZ@<hyh dBksj@l?ku Xkkjk


feV`h
feV`h
03003 Rough excavation not
exceeding 1.5 m deep and

getting out

Soft/dis
integrated

Hard
rock

ueZ@fo?k
fVr pV`ku

dBksj
pV`ku

Rs.

Rs.

Rs.

Rs.

Rs.

53.60

101.30

174.70

230.30

450.20

03004 Excavating over areas, n exc


1.5 m deep and getting out

03005 Add to items 03003 and


03004 for each additional 1.5
m or part thereof in depth

beyond the first 1.5 m


03006 Excavating in trenches, n exc
1.5 m wide and n exc 1.5 m in
depth; for foundation, etc. or
for shafts, wells, cesspits,
manholes, pier holes, etc. n
exc 10 sq m on plan and n exc
1.5 m in depth and getting out

03007 Add to item 03006 for each


additional 1.5m or part
thereof in depth beyond the
first 1.5 m
03008 Add to items 03004 to 03007
for scooping out from inside
and below the steining in
well sinking including use of
dredgers and all other
appliances, erection and
removal of weighed platform
and working in water
(measurement shall be for
area bound by external
circumference/ perimeter of

well x depth sunk)


03009 Returning, filling in, including
spreading, levelling, watering
and well ramming in layers

not exc 25 cm.

77.40

135.00

222.40

307.80

609.00

47.70

47.70

49.60

57.60

57.60

115.20

202.50

333.60

462.70

860.10

47.70

47.70

49.60

57.60

57.60

505.10

536.75

41.70

41.70

The items in this table shall not be allowed if posts with


pointed ends are directed to be driven into the ground.
Driving shall be measured separately under Section 7 Wood
work (Carpenters work).

03010 Excavating in post holes (or


similar holes) each n exc 0.5
cu. m, getting out, returning,
filling in and ramming earth
or broken rubble mixed with
earth around, in layers not

exceeding 25 cm,

0 3 0 0 3 fo"ke [kq n kbZ 1-5 eh- ls


vuf/kd xgjkbZ rFkk fudklh

0 3 0 0 4 mBk LFkkuksa esa 1-5 eh- ls


vuf/kd xgjkbZ dh [kqnkbZ

rFkk fudklh
03005 en 03003 o 03004 esa tksMas+
izFke 1-5 eh- xgjkbZ ls vf/kd
xgjkbZ;ksa esa izR;sd 1-5 ehvfrfjDr ;k mlds Hkkx gsrq

03006 [kkb;ksa esa [kqnkbZ 1-5 eh- ls


vuf/kd pkSMk+ bZ o 1-5 eh- ls
vuf/kd xgjkbZ okyh uhao vkfn
ds fy;s ;k LrEHkks]a dqvksa ey
dq.Mks]a eSugksyks]a ik;ksa ds xM~<s
vkfn ds fy;s tks 10 oxZehVj
lrg ij o 1-5 eh- ls vuf/kd

xgjkbZ ds rFkk fudklh


03007 tksMas en 03006 esa izFke 1-5 eh
ls vf/kd xgjkbZ ds fy, izR;sd
1-5 eh ;k mlds Hkkx ds fy;s

0 3 0 0 8 en 03004 ls 03007 esa tksM+sa]


vUnj o dq;sa ds xksys ds
uhps ls myhpdj ckgj
fudkyus ds fy;s Mstk o
vU; lk/kuksa] mBkoksa ds iz;ksx
lfgr o Hkkjh pcwrjksa dks
gVkuk o ikuh esa dk;Z djukA
eki dq,sa ds ckgjh
ifjeki@ ifjf/k xgjkbZ
ds fy;s gksxh

POST HOLES ETC.

EACH

fr ?ku ehVj

Soft/loo- Hard/dese soil


nse soil

55.60

LrEHkks a ds xM~ < s vkfn


bl rkfydk dh ensa ykxw ugha gksxh ;fn uqdhys Nksj LrEHkksa dks Hkwfe
esa izos'k ds fy;s dgk tkrk gSA pkyu dks [k.M 7 ds vUrxZr ydM+h
ds dk;Z c<+bZ ds dke esa ekik tk;sxkA
Mud

ueZ@<hyh dBksj@l?ku Xkkjk


feV`h
feV`h
Rs.

Rs.

77.80

114.60

0 3 0 0 9 okilh] HkjkbZ QSykuk lery


djuk] ikuh nsuk RkFkk 25
lseh- ls vuf/kd ijrksa esa

dqVkbZ djus lfgr

Rs.

Soft/dis
integrated

Hard
rock

ueZ@fo?k
fVr pV`ku

dBksj
pV`ku

Rs.

Rs.

232.50

312.40

iz R ;s d
03010 LrEHk ds fy, xM~<ksa dh [kqnkbZ
;k leku xM~<s izR;sd 0-5 ?kehls vuf/kd fudklh] okilh] HkjkbZ]
feh dqVkbZ rFkk 25 lseh- ls
vuf/kd ds iRFkj ds VqdM+ka s dks

25

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
ROUGH EXCAVATION, EXCAVATION OVER AREAS, IN TRENCHES, ETC. -Contd...
vle [kqnkbZ ps LFkkuksa [kkbZ;ksa vkfn esa [kqnkbZ tkjh--watering, and removing surplus soil to a distance n exc 50 feh esa feykdj ijr yxkuk ikuh nsuk] rFkk Qkyrw feh dks 50
m and making good surface
eh ls vuf/kd Qklys ij QSaduk o lrg dks Bhd djuk
SURFACE DRESSING
lrg iz l k?ku
Item 03011 & 03012 shall not be allowed in addition to items en 03011 & 03012 dks en 03001 ls 03010 ds vfrfjDr esa
03001 to 03010.
Lohdkj ugha gksxhA
PER SQUARE METRE
Soft/loose soil
Hard/dense soil
izfr oxZ ehVj
ueZ @ <hyh feV` h
dBksj@l?ku feV`h
03011 15 lseh xgjkbZ ls vuf/kd lrg
03011 Surface dressing n exc
Rs.
Rs.

15 cm deep
izlk/ku
7.90
10.00

5.30
03012

03012 Site Clearance


TIMBERING TO EXCAVATIONS
[kqnkbZ;ksa esa r[rscUnh
(a) The measurement for timbering shall be that part of
the face of excavation which is supported by timbering
and shall be paid for under the appropriate column
of the following rate table, e.g., the whole of the
timbering to a face 2.5 m deep shall be priced at the
rates in column 2 of this table.
(b) The measurement shall be taken before the excavation
is filled in and timbering is removed.
(c) The extra rate for tightly driven close butt-jointed
sheeting shall be allowed only for such portions of
the sides of excavations for which tightly driven close
butt-jointed sheeting is ordered, in writing, by the GE.
(d) Where timbering is ordered to be left permanently in
position 400 per cent extra shall be allowed on the
Materials and Labour rates.
PER SQUARE METRE
03013 Use and waste of
timbering as planking
and strutting for
excavations in trenches
in soil, including wales,
struts, open poling
boards, etc. as may be
necessary and fixing

and removal
03014 Ditto in shafts, wells,
cesspits, manholes and

pier holes

d r[rscna h dh eki [kqnkbZ ds ml Hkkx dh gksxh ftlesa r[rscna h


dh xbZ gS rFkk fuEu rkfydk dh visf{kr dkye esa nh xbZ njksa
ds vUrxZr gksxh vFkkZr~ 2-5 eh xgjkbZ rd dh lEkLr r[rcanh
dks bl rkfydk ds dkye 2 ds vuqlkj ewY;kafdr fd;k
tk;sxkA
[k [kqnkbZ dh eki [kqnkbZ Hkjus o r[rscna h gVkus ls igys yh tk;sxhA
x etcwrh ls VDdj tksM+ dh pn~nj ca/kkbZ ds fy, vfrfjDr
[kqnkbZ ds ik'oZ ds dsoy ml Hkkx ds fy, fn;k tk;sxk ftlds
fy, nqxZ vfHk;ark us VDdj tksM+ dh pknj ca/kkbZ dh fyf[kr
:i ls vkKk nh gksA
?k tgka r[rscanh dks lnk ds jgus nsus dh vkKk gks ogka **lkexzh
o Je** dh njksa esa 400 izfr'kr vfrfjDr nsus dh vuqefr gksxhA

Material & Labour

Except Timber

lkezxh o Je

yDdM+ jfgr

N exc. Exc.
Exc. 3 m N Exc.
1.5 m 1.5 m & & n exc. 1.5 m
deep nexc.3m 5 m deep deep
deep

Exc
Exc. 3 m
1.5 m & & n exc.
nexc.3m 5m deep
deep

vu 1-5 1-5 eha ls 3 eh ls vu 1-5 1-5 eh ls 3 ls vf/kaeh xgjk vf/k 3-0 vf/k- 5 xgjk vf/k- 3
5 eh ls
eh vu- eh vueh- vuvu-

Rs.
82.00

Rs.
97.20

Rs.
112.40

Rs.
18.50

Rs.
23.10

Rs.
27.80

95.90

111.10 126.30

32.40

37.00

41.70

03015 Ditto over areas (as for


basements, etc.) and
including use and waste
of raking shores and
fixing and removal 86.60

101.60 117.00

23.10

27.80

32.40

izfr oxZ ehVj


03013 yDdM+ dk mi;ksx vkSj
Nhtu tSls feh es]a [kkb;ksa
dh [kqnkbZ esa r[rkcanh o
iq'rkcanh djus ifr;ka] Vsdks]a
[kqys yxs r[rs vkfn ftudh
vko';drk gksxh] ds lfgr
rFkk lkexzh o Je] yxkbZ
o gVkbZ

03014 mi;qDZ r fudkl ukyh] dq,a ]as


eydqM
a ] eSugksy o ik;kas ds

xM~<ksa ds fy,
03015 mi;qZDr] ijh {ks= TkSls
rg[kkus vkfn rFkk Vsdksa ds
[kqjpus esa mi;ksx o Nhtu
rFkk yxkbZ o mBkbZ lfgr

26

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
PER SQUARE METRE
03016 Extra only on item no
03013 to 03015 above
if tightly driven close
butt-jointed sheeting is
ordered including
packing cavities
behind the sheeting
with suitable material
where necessary.

Material & Labour

Except Timber

lkezxh o Je

yDdM+ jfgr

N exc. Exc.
Exc. 3m N Exc.
1.5m 1.5m & & n exc. 1.5m
deep n exc.3m 5m deep deep
deep

Exc
Exc. 3m
1.5m & & n exc.
n exc. 5m deep
3m deep

vu 1-5 1-5 eha ls 3 eh ls vu 1-5 1-5 eh ls 3 ls vf/ka


eh xgjk vf/k 3-0 vf/k- 5 xgjk vf/k- 3
5 eh ls
eh vu- eh vueh- vuvu-

Rs.
49.70

Rs.
51.60

Rs.
56.20

Rs.
7.40

Rs.
9.30

Rs.
13.90

izfr oxZ ehVj


03016 mi;qDr en 03013 ls 03015
esa fdlh ij vfrfjDr dsoy
rc tc etcwr VDdj tksM+
dh pknj ca/kkbZ dh vkKk nh
xbZ gks o tgka vko';d gks
ogka fjfDr;ksa esa mi;qDr
lkexzh dh HkjkbZ dh xbZ gks

SPREADING, LEVELLING AND RAMMING IN FLOORS, ETC.


Q'kksZ vkfn esa QSykuk lery djuk o dqVkbZ djuk
For measurements of items 03017 & 03018 special en 03017 o 03018 dh eki ij fo'ks"k 'krZ 3-6 ykXkw gksXkh
condition 3.6 shall apply.
PER CUBIC METRE

Rs.

03017 Spreading and levelling in layers n exc. 25

cm thick

izfr ?ku ehVj


03017 25 lseh eksVkbZ ls vuf/kd dh ijrksa esa Qsykuk o

lery djuk
03018 tksMa s + vko';drkuqlkj ikuh Mkydj vPNh dqVkbZ ds fy,

19.90
03018 Add for well ramming including watering
as required
31.80

M&L
Except sand
03019 Sand filling under floors or in
Rs.
Rs.
foundations including watering
678.20
31.90

and consolidation

03019
03019Q'kksZ] uhoksa esa ikuh fNM+dj njslh djus
lfgr ckyw dh HkjkbZ djuk

FORMING EMBANKMENTS AND TRAVERSES


rVca/k vkSj Vs<s+ es<s+ iFk pe cukuk
(a) For measurements of items 03020 & 03021, Special
Condition 3.6 shall apply.
(b) The rates apply to filling in roads, berms, embankments, traverses, etc. of any profile, upto 8 m in height
above base.
(c) The rates include for supplying and fixing temporary
profiles and removing same as the work proceeds.
(d) Where compaction of earth filling is ordered to be
carried out under optimum moisture conditions to
the specified percentage of standard proctor density
not less than 95 per cent, rates for forming
embankments shall be increased by 10 per cent.
PER CUBIC METRE
03020 Forming embankments including
raising (or lowering) earth,
spreading in layers n exc. 30 cm thick;
watering, ramming/rolling and
finishing to required size, shape,
etc., n exc. 1.5 m high from base
03021 Add for each additional 1.5 m or part

thereof in height above the first 1.5 m

d en 03020 o 03021 dh eki ds fy, fo'ks"k 'krZ 3-6 ykxw gksxhA


[k fdlh Hkh :ijs[kk dh lM+dks]a iVfj;ks]a rVca/kks]a Vs<+ es<s iFkksas vkfn
esa vk/kkj ls 8 eh- pkbZ rd HkjkbZ djus ij ;g njsa ykxw gksx
a hA
x bu njksa esa vLFkkbZ <kpksa dh vkiwfrZ djuk o yxkuk rFkk
T;ksa&T;ksa dke vkxs c<+rk gS mUgsa fudkyuk 'kkfey gSA
?k tgka vuqdwy ueh okyh fLFkfr;ksa esa fufnZ"V 95 izfr'kr vkSlr
ds eku ?kuRo izcU/ku dh Bksl feh HkjkbZ dh vkKk nh tkrh
gS rks rVca/k cukus dh njksa esa 10 izfr'kr dh o`f) dh tk;sxhA

Solids

Rocks

Rs.

Rs.

50.70
49.60

izfr ?ku ehVj


03020
03020rVca/k cukus ds fy, tehu dks Wpk
djuk;k uhpk djuk] 30 lseh ls
vuf/kd eksVkbZ esa feh QSykuk ikuh
fNM+dj dqVkbZ djuk@jksyj pykuk
rFkk vk/kkj ls 1-5 eh ls vuf/kd pkbZ
rd visf{kr vkdkj] vkd`fr esa laiwfrZ
03021
03021tksMa+s igys 1-5 eh ls vf/kd dh WpkbZ
ij izR;sd 1-5 eh ;k mlds Hkkx gsrq

27

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
BORE HOLES FOR UNDER-REAMED PILES AND BORED CASE IN SITU PILES
uhps ifjos/ku ikby ds fy;s izos/ku Nsn rFkk izosf/kr izoyu bu lhVw ikby esa
(a) The rates in items 03022 to 03028 include for the
followings :(1) Roughly levelling the ground in positions where
piles are to be provided.
(2) Marking the position of pile by pegs and boring guide
(b) Item 03022 covers any dimension of under-reaming
upto 2 times the diameter of bore hole.
(c) The rates for item 03022 to 03024 do not include use
of drilling fluid in case of unstable pile bores.
EACH
03022 Boring holes 2 m deep in soil
for under-reamed piles and
getting out and disposal of
spoil to a distance of n exc.

50 m
03023 Add to above item for each
additional under-reaming

d en 03022 ls 03028 dh njksa esa fuEu 'kkfey gS%&


1 tgka ikby [kMs+ djus gSa ml LFkku dks eksVs rkSj ij lery
djukA
2 [kaVw h ;k izc/s ku ekxZ n'kZd }kjk ikby dh fLFkfr fpfUgr djukA
[k izo/s ku Nsn dh ifjf/k ds 2 xq.kk rd ds ifjos/ku ifjf/k dks en
03022 lekfgr djrh gSA
x en 03022 ls 03024 rd dh njksa esa vfLFkj ikby izos/ku ds
ekeys esa ojHkkbZ ?kksy dk iz;ksx 'kkfey ugh gSA
iz R ;s d

Diameter of piles

ikby dh ifjf/k feeh esa


200 mm
Rs.

250 mm
Rs.

300 mm
Rs.

204.50

246.20

285.90

81.40

103.30

123.10

03022 tehu esa 2 eh rd] ifjos/ku ikby


ds fy, izos/ku Nsn djuk rFkk
feh fudkyuk rFkk mls 50 eh
vuf/kd nwjh ij Qsaduk

03023 ij dh en esa izR;sd vfrfjDr


ifjos/ku ds fy;s tksM+sa

PER RUNNING METRE

iz f r ehVj

03024 Add to item 03022 for each


metre depth (intermediate
depths to be paid prorata)

03024 en 03022 esa izfr ehVj xgjkbZ ds


fy, tksM]a s + ek/;fed xgjkbZ ;Fkkuqikr

ns; gksxh

EACH
03025 Boring for Bored cast in situ
piles 16 metres in soil and
getting out and disposal of
spoil to a distance 50 metres
using DMC method (Direct

mud circulation)
03026 Add/Deduct to above for

each metre depth

PER 10 CENTIMETRE

55.60

69.50

81.40

350 mm

430 mm

500 mm

8273.60

9501.50

03025 tehu esa 16 eh lhVw ikby esa Nsn


fudkyus ds fy, ojHkkbZ dk;Z rFkk
feh fudkyuk o Mh ,e lh i)fr
lh/ks iad ifjpkyu dk iz;ksx
djrs gq, 50 eh nwj Qsaduk
10779.30

502.50

579.80

656.50

iz R ;s d

03026 izR;sd ,d ehVj vfrfjDr@de ds

fy, ij dh en esa tksMas+ @?kVk;sa


izfr 10 lsaVhehVj

03027 Chiselling / cutting through


for boring for cast in situ piles
in soft rock and getting out
and disposal of spoil to a
distance of n. exc. 50 metres

03027 uje pku es lhVw ikby ds fy;s


HkjikbZ fNnz dk;Z djus ds fy, Nsuas h
dk;Z@ dVkbZ dk;Z rFkk feh
fudkyuk o feh dks vuf/kd 50

eh nwj Qsd
a uk

03028 -Do- but in hard rock

03028 mi;qZDr] fdUrq dBksj pku esa

28

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
REMOVAL OF SPOIL

eyok gVkuk
(a) The removal of spoil resulting from excavation d Bsdn
s kj }kjk [kqnkbZ djus ls fudys eyos dks gVkus dk Hkqxrku
performed by the Contractor shall be paid for, on the
[kqnkbZ ls igys l?ku va'kksa dh eki ds vk/kkj ij gksxh ;fn l?ku
basis of solid contents measured before excavation. If
va'kksa dh eki djuk dfBu ik;k tkrk gS ;k vO;ogkfjd gS rks
measuring of the solid contents is found difficult or
cjkcj ds l?ku va'kksa dks tkuus ds fy;s fuEu vkSlr ls dVkSrh
impracticable, the following percentage deductions
dh tk;sxhA
shall be made to arrive at equivalent solid contents :
1 tgka Bksl HkjkbZ dks ;kaf=d e'khuksas }kjk fd;k x;k gks mldks
(1) 10 per cent deduction in all cases of consolidated
NksMd
+ j vkSj lHkh Bksl HkjkbZ esa 10 izfr'kr dh dVkSrh gksxh
fills except where the consolidation is done by
heavy mechanical machinery or to the specified
;k flok; mlds tc fufnZ"V ekud izkDs Vj ?kuRo vuwdy
q
standard proctor density not less than 95 per cent
ueh okyh fLFkfr;ksa esa 95 izfr'kr ls de u gks] blesa dVkSrh
under optimum moisture conditions, in which
5 izfr'kr dh tk;sxhA
case the deduction shall be 5 per cent.
(2) No deduction shall be made in the case of consolidated fills in confined situations like floors.
(3) 20 per cent deduction when spoil excavated from
soft/loose soil or hard/dense soil is measured in
loose stacks or in carts or lorries.

2 Q'kZ tSlh lhfer fLFkfr;ksa ds ekeys esa dksbZ dVkSrh ugha gksxhA
3 tc uje@<hyh tehu ;k dBksj@l?ku tehu dh [kqnkbZ
ls fudys eyos dks <hys <sjksa esa ;k xkfM+;ksa ;k eksVj xkfM+;ksa
esa ekik tk; rks dVkSrh 20 izfr'kr gksxhA
4 ;fn [kksnh xbZ feh jsr gS rks dksbZ dVkSrh ugha gksxhA

(4) No deduction shall be made when spoil excavated


is sand.
(5) 50 per cent deduction when spoil excavated from
soft/disintegrated rock or hard rock is measured
in loose stacks or in carts or lorries.
(b) In working out lead for large areas of excavation, the
excavated areas shall be divided into suitable blocks
and for each block the distance from the centre of block
to the centre of placed earth pertaining to the
corresponding block shall be taken as lead.
(c) The rates for removal of spoil include for loading into
and unloading from barrows, carts, baskets, etc., or
mechnical transport vehicles. In the case of spoil heaps
which, in the opinion of the GE, have consolidated
and require loosening before removal half the rate for
rough excavation in soft soil shall be allowed in
addition. However, this additional payment shall not
be permitted for spoil heaps requiring loosening due
to Contractors default. Decision of GE whether a spoil
heap needs loosening or not, shall be final and binding.
(d) Where rates for excavation include for removal n exc.
50 m, item 03029 shall be deducted from the
appropriate rates for removing to the full distance,
unless two separate removals have been authorised
by prior written order of GE.
(e) Removal shall be assumed to be done by the shortest
practicable route, and payment shall not necessarily
be made for the route actually taken. No additional
payment shall be allowed for roads in bad repair,
gradients, or carting over unconsolidated ground.
(f) The item for raising is exclusive of moving horizontally. It shall not be allowed when appropriate item
for excavations, etc., include allowance for specified
depths, nor shall it be allowed in the case of removal
beyond 250 metres.
(g) Removal exceeding a distance of 15 km shall either be
done by other agency or under a separate arrangement
with the same Contractor.

[k

?k

5 tc uje@fo?kfVr pku ;k dBksj pku esa [kqnkbZ ls


fudys eyos dks <hys <sjksa ;k xkfM++;ksa ;k eksVj xkfM++;ksa esa
ekik tk; rks dVkSrh 50 izfr'kr dh tk;sxhA
[kksns x;s fo'kky {ks=ksa esa nwjh fudkyus ds fy;s] [kksns x;s {ks=ksa
dks mi;qDZ r Hkkxksa esa ckaVk tk;sxk rFkk izR;sd Hkkx ds fy;s mlds
dsUnz ls ml Hkkx dh feh dks Mkys x;s LFkku ds dsUnz rd ds
Qklys dks nwjh ds :i esa fy;k tk;sxkA
eyok gVkus dh njksa esa <syksa] xkfM+;ksa Mkfy;ksa vkfn ;k eksVj
okguksa esa feh Hkjuk] o muls mrkjuk 'kkfey gSA eyok ds <sjksa
ds ekeys esa tgka nqxZ vfHk;ark ds fopkj esa Bksl gks xbZ gS rFkk
gVkus ls igys mls <hyk djus dh vko';drk gS rks uje feh
dh [kqnkbZ dh njksa ds vk/ks dk vfrfjDr Hkqxrku djus dh
vuqefr gksxhA fQj Hkh ;g vfrfjDr ml n'kk esa ugha fn;k
tk;sxk tc eyok Bsdsnkj dh xYkrh ds dkj.k Bksl gqbZ gksA
eyok ds <sj dks <hyk djus dh t:jr gS ;k ugha] bl fo"k;
esa nqxZ vfHk;ark dk QSlyk vafre rFkk ck/; gksxkA
tgka [kqnkbZ dh njksa esa 50 eh- ls vf/kd ds fy, gVkuk 'kkfey gks
rks iwjh nwjh dh gVkbZ ds fy, en 03029 dks ml lEcf/kr en esa
ls ?kVk fn;k tk;sxk tc rd fd nqxZ vfHk;ark dh iwoZ fyf[kr vkKk
}kjk nks vyx feh fxjkus ds dk;Z dks vf/kd`r u fd;k x;k gksA
gVkus ds dk;Z dks lcls NksVs O;ogkfjd ekxZ }kjk fd;k x;k le>k
tk;sxk rFkk ;g t:jh ugha gksxk fd Hkqxrku okLro esa viuk;s x;s
ekxZ ds fy;s fd;k tk;sA lM+dksa dh [kLrk gkyr] x<+kas ;k vlery
Hkwfe ij xkM+h pykus ds fy, vfrfjDr dh vuqefr ugha gksxhA

p ij mBkus dh en esa leryh; ?kqeko 'kkfey ugha gSa bldh


Lohd`fr ugha nh tk;sxh( tc [kqnkbZ vkfn dh mi;qDr en esa
fufnZ"V xgjkb;ksa ds fy, Hkkk 'kkfey gksrk gS( 250 eh- ls
vf/kd dh nwjh ij feh fxjkus dh vuqefr Hkh ugha gksxhA
N 10 fdeh ls vf/kd dh nwjh ij QSdus ds dk;Z ;k rks fdlh nwljh
laLFkk ls ;k mlh Bsdns kj ls izFkd vuqc/a k djds djok;k tk;sxkA

29

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
REMOVAL OF SPOIL Contd...

eyok gVkuk & tkjh


(h) Items 03029 to 03035 refer to every description of
excavated material.
(j) Items 03029 and 03030 are not applicable, if payment
is made under item 03031.
(k) In case excavated materials are removed to the place
of use or disposed directly without being first placed
clear of the edge of excavation, no adjustment shall
be made in the rates for removal of spoil.
PER CUBIC METRE
03029 Removing excavated material
n exc. 50m and depositing where
directed at a level n exc. 1.5 m
above the starting point
03030 Add for each additional 50 m
or part thereof beyond 50 m and

upto a total distance of 250 m.


03031 Removing excavated material
exc. 250 m but n exc. 500 m and
depositing where directed
03032 Add to item 03031 for each
additional 500 m or part thereof
beyond 500 m and upto total

distance of 1.5 km
03033 Removing excavated material
exc. 1.50 km but n exc. 5 km and
depositing where directed
03034 Add to item 03033 for each
additional l km or part thereof,
beyond 5 km upto total distance

of 15 km
03035 Raising only, spoil from
excavations, etc. (Where not
otherwise provided for) every
additional 1.5 m or part thereof
beyond the first 1.5 m when the
spoil is to be deposited at a level
exc. 1.5 m above the starting

point

t [kksns x;s izR;sd o.kZu ds fy, en 03029 ls 03035 ns[ksaA


> ;fn Hkqxrku en 03031 esa fd;k x;k gS rks en 03029 o 03030
ykxw ugha gksxhA
= ;fn [kqnkbZ dh lkexzh dks iz;ksx ds LFkku ij Mkyk x;k gS ;k
fcuk [kqnkbZ ds fdukjs ij Mkyus ds] lh/kk fuiVkjk fd;k x;k
gS rks eyok gVkus ds dk;Z esa dksbZ lek;kstu ugha gksxkA

Soils

Rocks

Rs.

Rs.

03029

96.10

131.80

03030
13.10

15.30

03031
149.40

200.60

03032
12.00

14.00

208.30

235.80

15.00

18.00

37.70

47.70

izfr ?ku ehVj


[kksnh xbZ lkexzh dks 50 eh dh vuf/kd
nwjh ij Mkyuk rFkk jckuxh fcUnq ls 1-5 eh
vuf/kd apkbZ ij funskkuqlkj tek djuk
izR;sd 50 eh dh vf/kd nwjh ds fy;s
izR;sd 50 eh ;k mlds Hkkx ds fy, dqy
nwjh 250 eh-] esa tksMas+
[kksnh xbZ lkexzh dks 250 eh- ls vf/kd o 500
eh- ls vuf/kd nwjh ij Mkyuk o
funsZkkuqlkj tek djuk
tksM+ a s en 03031 esa izR;sd 500 eh ;k mlds Hkkx
500 eh ls vf/kd o dqy nwjh 1-5 fdeh rd

03033 [kksnh xbZ feh dks 1-5 fdeh ls vf/kd


fdUrq 5 fdeh vuf/kd nwjh ij vknskkuqlkj
tek djuk
03034 tksMsa+ en 03033 esa 5 fdeh ls vf/kd ij
izfr 1 fdeh vfrfjDr ;k mlds Hkkx ds
fy;s dqy 10 fdeh rd
03035 [kqnkbZ dh feh dks dsoy apk mBkus
vkfn ds dk;Z esa tgka vU;Fkk O;oLFkk u
gks izkjfEHkd fcUnq ls 1-5 eh ls vf/kd
apkbZ ij tek djus ij] tgka feh dks
lrg ls 1-5 eh- ls vf/kd apkbZ rd tek
djuk gks ogka igys 1%5 eh ls vf/kd ij
izR;sd 1-5 eh ;k mlds Hkkx ds fy,

CUTTING DOWN TREES

isM+ dk dkV fxjkuk


(a) The girth of the trees shall be taken at 1 m above
ground level.
(b) Grubbing up of tree trunk shall include digging out
roots upto 60 cm below ground level or 15 cm below
formation level whichever is lower

d isM+ dk ?ksjk tehu ls 1 eh mij ls ekik tk;sxkA


[k isM+ ds /kM+ dks dkV fxjkus esa] tM+ksa dks tehu ls 60 lseh uhps
rd ;k tM+sa cuus ds LFkku ls 15 lseh uhps rd tks Hkh de gks
[kksn dj fudkyuk kkfey gksxkA

30

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
CUTTING DOWN TREES Contd..

isM+ dk dkV fxjkuk tkjh..


EACH

iz R ;s d

Girth of tree

isM+ dk ?ksjk
Exc.
30 cm
and
n exc.
100 cm

Exc.
100 cm
and n exc.
150 cm

Exc.
150 cm
and n exc.
200 cm

Exc.
200 cm
and n exc.
250 cm

Exc.
250cm
and
n exc.
300 cm

Rs.

Rs.

Rs.

Rs.

Rs.

377.50

737.10

856.90

980.80

1010.60

559.20

889.90

1005.90

1148.30 1188.00

03036 Felling of tree exc. 30


cm girth including
cutting of trunk, and
branches
and
stacking of serviceable
material and disposal
of unserviceable
material to a distance
n exc. 50 m and

clearing site

03036 30 lseh ?ksjs ds isM+ ds /kM+ o


kk[kkvksa dks dkVdj fxjkuk
rFkk mi;ksxh lkexzh dks lafpr
30 lseh ls 100 lseh 150 lseh 200 lseh 200 lseh
djuk rFkk vuqi;ksxh lkexzh
vf/kd o ls vf/kd o ls vf/kd o ls vf/kd o ls vf/kd o
dks 50 eh dh vuf/kd nwjh
100 lseh 150 lseh 200 lseh 250 lseh 300 lseh
ij Mkyuk o ml LFkku dks
ls vuf/kd ls vuf/kd ls vuf/kd ls vuf/kd ls vuf/kd
lkQ lqFkjk djuk

03037 Grubbing up tree


trunk including
cutting of trunk
portion protruding
over ground, digging
out roots, filling holes
and leveling off
ground, stacking of
serviceable material
and removing of
unserviceable
material to a distance
n exc. 50 m and

clearing site

03037 isM+ dks dkV fxjkus ds dk;Z


es]sa /kM+ dks dkV dj fZxjkuk]
tM+sa fudyuk] xM~<s Hkjuk
rFkk tehu dks lery
djuk] mi;ksxh lkexzh dks
lafpr djuk o vuqi;ksxh
lkexzh dks 50 eh ls vuf/kd
nqjh ij Mkyuk rFkk ml
LFkku dks lkQ&lqFkjk djuk

HAND PACKING, FILLING AND HARDCORE

gkFk ls lesVuk] HkjkbZ o dqVkbZ djuk


d 03020] 03021 o 03029 ls 03032 dh enksa ij] en 03038 ds
vUrxZr lkexzh dks NkaVus o gVkus ds dk;Z dk vfrfjDr Hkqxrku
ugha gksxkA
(b) The rates for except materials include for breaking [k **lkexzh jfgr** dh njksa esa ,e bZ ,l dh iqjkuh lkexzh dks
old M.E.S. materials to the sizes required.
visf{kr vkdkj esa rksM+us dk dk;Z kkfey gSA
(c) Measurements for item 03038 shall be of stacks.
x en 03038 ds fy, eki pV~Vksa esa yh tk;sxhA
(d) Measurements for items 03042 and 03043 shall be ?k en 03042 o 03043 dh eki Bksl lap;u ds ckn dh tk;sxhA
(a) Selection and removal of materials under item 03038
shall not be paid in addition to items 03020, 03021
and 03029 to 03032.

those after consolidation.

PER CUBIC METRE


03038 Selecting stone, brick, concrete, etc. suitable
for handpacking, filling of hardcore from
excavated spoil heaps, removing and piling
in convenient places within 50m of spoil
heaps, etc. and raising or lowering to
required level (measured after selection)

Rs.

139.00

izfr ?ku ehVj


03038 [kksnh xbZ feh ds <sj es ls gkFk ls lesVus] Hkjus o
dqVkbZ djus ds dk;Z ds fy, mi;qDr] iRFkj bZV]
dahV vkfn dh NaVkbZ djuk rFkk feh ds <sj ls 50
eh ds vUnj lqfo/kktud LFkku ij pV~Vs yxkuk o

visf{kr Lrj rd mBkuk ;k uhps djuk eki NaVkbZ


ds ckn gksxh

31

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
HAND PACKING, FILLING AND HARDCORE Contd..
gkFk ls lesVuk] HkjkbZ o dqVkbZ djuk tkjh..
PER CUBIC METRE

03039 Hand
packing
(any
thickness) at back of walls
over arches etc. and raising
(or lowering) to the required

level
03040 Loose filling with aggregates
of gauge 80 to 150 mm in
soakage pits, soakage wells
03041 Ditto of gauge 40 to 80 mm
03042 Hardcore of gauge n exc. 63
mm, deposited, spread and
levelled in layers n exc. 15
cm thick, watered and
rammed to a true surface
03043 Hardcore of guage exc 63mm
but n exc. 100 mm, deposited,
spread and levelled in layers
n exc. 15 cm thick, watered
and rolled/rammed to a true

surface

Broken stone
or boulders

VwVs iRFkj
;k jksM+h

izfr ?ku ehVj

Except
Material

M&L

lkexzh ,ao Je
Broken
bricks

VwVh
bVsa

lkxxz h
jfgr

Rs.

Rs.

Rs.

828.50

669.90

152.90

538.10

520.50

38.70

606.20

570.90

77.40

895.10

776.70

154.90

821.10

776.70

154.90

03039 nhokjksa ds ihNs MkVksa ds ij vkfn esa


fdlh Hkh ?kuRo dh gkFk ls HkjkbZ
djuk rFkk visf{kr Lrj rd ij

djuk ;k uhps djuk vkfn


03040 lks[kh xM~<s] lks[kh dqvksa vkfn esa 80
ls 150 feeh ekiu dh dqy <hyh

HkjkbZ djuk
03041 mi;qZDr] dqy HkjkbZ 40 ls 80 feeh
03042 63 feeh ls vuf/kd ekiu dk dqVkbZ
dk;Z] HkjkbZ djuk] QSykuk o 15 lseh
vuf/kd eksVkbZ esa lery djuk rFkk
ikuh Mkydj dqVkbZ djds cf<+;k

lrg cukuk
03043 63 feeh ls vf/kd fdUrq 100 feeh
vuf/kd ekiu dk dqVkbZ dk;Z] QSykuk
15 lseh vuf/kd eksVkbZ ikuh Mkydkj
jksyj@/kjeqVh dqVkbZ djds cf<+;k

lrg cukuk

SHINGLE/MOORUM FILLING IN FLOORS, ETC.

QkkZs vkfn esa ctjh@eqje dh HkjkbZ


Measurements for items 03044 and 03045
shall be those after consolidation.
PER CUBIC METRE
03044 Shingle filling in floors or pavings, laid
in layers n exc. 15 cm thick, spread,
levelled, and blinded with earth and

rammed including watering


03045 Moorum/red bajri filling in floors or
pavings, laid in layers n exc. 15 cm
thick, spread, levelled and rammed

including watering

Rs.

694.80

542.60

en 03044 o 03045 dh eki Bksl te tkus ds ckn


dh gksxhA
izfr ?ku ehVj
03044 QkksZ ;k fcNkouksa esa ctjh dh 15 lseh ls
vuf/kd dh ijr fcNkuk] QSykuk] lery
djuk] feh ls Nsn Hkjuk rFkk ikuh fNM+d

dj dqVkbZ djuk
03045 QkksZ ;k fcNkouksas esa 15 lseh vf/kd eksVh
eqje@yky ctjh dh ijr yxkuk QSykuk]
lery djuk rFkk ikuh lfgr dqVkbZ djuk

32

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
ANTI-TERMITE TREATMENT (Pre & Post Construction)

nhed jks/kh mipkj fuekZ.k iwoZ o ckn


PER CUBIC METRE (of mound)
03046 Breaking the termite mounds, making
holes with crow bars and pouring antitermite chemical emulsion at the rate of 4

litres per cubic metre of mound


PER SQUARE METRE
03047 Treating the bottom and sides of excavation
at the rate of 5 litres of emulsion per square

metre of surface area


03048 Treating the backfill in contact with
foundation at the rate of 7.5 litres of
emulsion per square metre of vertical
surface (Area of the sub structure in contact

with backfill to be measured)


03049 Treating the top surface of filled earth at
the rate of 5 litres of emulsion per square

metre of surface
03050 Treating the soil under plinth protection
at the rate of 5 litres of emulsion per square

metre of surface area


PER RUNNING METRE
03051 Treating the soil along with external
perimeter of building at the rate of 2.25 litre

of emulsion per metre of the perimeter wall

M&L

Except
emulsion

lkexz h feJ.k
o Je jfgr
Rs.
73.40

Rs.
12.20

izfr ?ku ehVj leqPp;


03046 nhed leqPp;ksa dks rksM+us ds fy, lCcy ls
Nsn djuk o 1 ?ku ehVj esa 4 yhVj dh nj
ls nhed jks/kh jlk;fud ?kksy Mkyuk

izfr oxZ ehVj


03047 ry {ks= ds ,d oxZ eh esa 5 yhVj dh nj ls ?kksy
dk [kqnkbZ ds ry o cxyksa esa mipkj djuk

80.60

4.60

126.80

12.20

80.60

4.30

80.60

4.30

03050 dqlhZ j{k.k ds uhps dh feh es]a lrgh {ks= ds 1 oxZehesa 5 fyVj ds fglkc ls ?kksy dk mipkj djuk

4.30

iz f r ehVj
03051 Hkou ds pkjksa vksj dh feh dk 2-25 fy ifjeki
ds izfr 1 ehVj esa ?kksy dk mipkj djuk

38.60

03048 uhoa ls lVh gqbZ lkFk dh HkjkbZ esa 7-5 fy izfr


oeh lh/kh lrg v/kcus fuekZ.k dk og {ks= tks
izB HkjkbZ ls tqMk+ gqvk gS ij ?kksy dk mipkj

djuk
03049 feh Hkjh lrg ds ij lrg ds ,d oxZ eh
esa 5 yhVj ?kksy dk mipkj djuk

fuekZ . k mijka r
izfr oxZ ehVj

Post Construction
PER SQUARE METRE
03052 Providing and injecting chemical
emulsion for Post Constructional
Antitermite Treatment along external
wall where the apron is not provided
using chemical emulsion at the rate of 7.5
litres per sq.m of the vertical surface of
the sub-structure to a depth of 300mm
including excavating channel along the

wall and rodding etc. complete

03052 fuekZ.k mijkar ds nhed jks/kh jlk;fud dh


O;oLFkk djuk rFkk ckgjh nhokj ds lkFk tgka
vkoj.k dh O;oLFkk ugha gS ogka nhokj ds lkFk
300 feeh xgjh ukfy;ka [kksn dj NM+ Ja[` kyk
lfgr izfr oxZ eh 7-5 fy jlk;fud ?kksy dk
iz;ksx djrs gq, ?kksy vUnj Hkj ds laifw rZ
171.60

57.10

PER RUNNING METRE


03053 Along the external wall below concrete or
masonry apron using chemical emulsion
@ 2.25 litres per linear metre including

drilling and plugging holes etc. in apron.

53.20

18.90

iz f r ehVj
03053 dahV;k fpukbZ vkoj.k es ojHkkbZ Nsn djds
2-25 fy izfr js[kh; eh dh nj ls jlk;fud
?kksy Hkjuk rFkk Nsn can djuk

izfr oxZ ehVj

PER SQUARE METRE


03054 Treatment of soil under existing floors
using emulsion @ one litre per hole,
300mm apart including drilling and
plugging 12mm dia holes with cement
mortar 1:2 (1 cement: 2 coarse sand) to

match the existing floors

72.30

57.00

03054 fo/keku QkksZa ds uhps dh feh es]a 300 feeh


nwjh ij 12 feeh O;kl ds Nsnksa esa ?kksy dk
mipkj djuk rFkk Nsnksa esa 1%2 1 lhesVa % 2
eksVh ckyw ls fo|eku dk;Z dks feykrs gq, HkjkbZ

djds can djuk

33

SECTION 3

SECTION 3 EARTH WORK


[k.M 3 feh dk;Z
ANTI-TERMITE TREATMENT (Pre & Post Construction) Contd..
nhed jks/kh mipkj fuekZ.k iwoZ o ckn tkjh ..

PER SQUARE METRE


03055 Of voids in masonry using chemical
emulsion one litre per hole, at 300mm
intervals including drilling holes at 45
degree and replugging them with
cement mortar 1:2 (1 cement : 2 coarse
sand) to match the existing floors

Rs.

Rs.

72.30

57.00

izfr oxZ ehVj


03055 fpukbZ dh f>fj;ksa esa 300 feeh ds Qklys ij
45 vak dks.k Nsnksa esa izfr Nsn 1 fyVj
jlk;fud ?kksy dk iz;ksx djds Nsnksa dks 1%2
ds lhesaV elkys 1 lhesaV % 2 eksVh ckyq ls
Nsnksa dks can djuk

21.40

iz f r ehVj
03056 ydM+h dk;Z ds laidZ fcUnqvksa ij uhps dh
vksj 6 feeh O;kl ds 150 feeh nwjh ij 45
vak dks.k ds Nsnksa esas jlk;fud DyksjkfM+u
?kksy rsy ;k feh ds rsy vk/kkfjr ?kksy
izfr Nsn 0-5 fy Mky dj Nsnksa dks can djuk

M&L

lkexz h
o Je

Except
emulsion

feJ.k
jfgr

PER RUNNING METRE


03056 At points of contact of wood work by
chemical emulsion (in oil or kerosene
based solution) @ 0.5 litre/hole by
drilling 6mm dia holes at a downward
angle of 45 degree at 150mm centre to

centre and sealing the same

27.60

MATERIALS (Supplied only)

lkexzh dsoy vkiwfrZ


bZV jksM+h] iRFkj jksM+h dh njksa esa lkexzh dks fu;afer
<sjksa@pV~Vksa esa] eki ds fy;s yxkuk kkfey gSSA

The rates for broken bricks, stones, aggregates, etc.,


include for stacking materials in regular heaps/
stacks for measurement.
PER CUBIC METRE

03057 Aggregate for loose filling, of gauge

80 mm to 150 mm graded
03058 Ditto, of gauge 40 mm to 80 mm

graded
03059 Hard core, broken to gauge n exc 63

mm
03060 Ditto, broken to gauge exc 63 mm

and n exc 100mm

Broken
stone/
boulders
Vw V k iRFkj@jks M + h
Rs.
499.40

Broken
bricks
VwVh bZVsa

528.70

493.50

528.70

499.40

528.70

493.40

03057 <hyh HkjkbZ ds fy, 80 feeh ls 150 feeh


ekiu dk oxhZd`r leqPp;

03058 mi;ZqDr] 40 feeh ls 80 feeh oxhZd`r


leqPp;

03059 dqVkbZ dh 63 feeh ls vuf/kd VwVh gqbZ

ekiu dh jksM+h
03060 mi;qZDr 63 feeh ls vf/kd o 100 feeh

vuf/kd

Rs.

PER KILOGRAM
03061 Blasting powder

Rs.
481.70

izfr ?ku ehVj

PER RUNNING METRE

03062 Safety fuse


PER LITRE
03063 Chlorophyriphos or lindane emulsifiable
concentrate conforming to IS:8944 or IS 632

respectively

58.70

izfr fdxzk
03061 foLQksVd pw.kZ

23.50

305.50

iz f r ehVj

03062 lqj{kk iyhrk

iz f r fyVj

03063 dykjksQfjQksl ;k fyaMus laxr ik;lhdj.k ;ksX; Hkk ek


8944 ;k 632 ds vuq:i

34

SECTION 4

SECTION 4 CONCRETE
[k.M 4 dahV
SPECIAL CONDITIONS

foksk krsZ
4.1 Measurements
4.1.1 Surface drains or channels shall be measured thus :
(Refer Fig. 4.1.1 at the end of Section 4)
4.1.2 Thickness of slabs, partitions, etc., and sectional
dimensions in case of posts, columns, beams and
the like shall be measured to the nearest half
centimetre. Measurement of concrete shall be
exclusive of the thickness of finishing plaster
mentioned in 4.11.16 (Part I).
4.1.3 No deductions or additions shall be made on any
account for:
(1) Ends of dissimilar materials (for example, joists,
beams, posts, girders, rafters, purlins, trusses,
corbels, steps, etc.) upto 500 sq cm in section
each;
(2) Openings upto 0.1 sq m each; no extra labour
for forming such openings shall be measured;
Note.In calculating the area of an opening, the size of
opening includes thickness of any separate lintels
or cills.
(3) Joints of any kind (plain, rebated, locking,
tongued, grooved, etc.);
(4) Mouldings, drip mouldings, chamfers, splays,
rounded or coved angles, beads, grooves and
rebate upto 10 cm in width or 15 cm in girth;
(5) Stops, mitres, returns, rounded ends, junctions,
dishings, etc.;
(6) Wall plates and the like upto 10 cm deep;
(7) Small voids, such as the shaded portions in the
following sketches (measured throughout as
AxB) when these do not exceed 40 sq. cm in
section each. If they exceed 40 sq. cm each, the
work shall be measured net. In case of Fig.6
and 7 average of B and B shall be taken;

4-1 eki
4-1-1 lrgh ukfy;k ;k ufydk;s bl izdkj ls ekih tk;sxhA [kaM
ds var esas fp= laa- 4-1-1 ns[ksa
4-1-2 ifV;ks]a foHkktdksa vkfn dh eksVkbZ rFkk [kEHkks]a vk/kkjks]a /kjfu;ksa
o leku esa ifjeki fudVre vk/ks lsaVhehVj rd ekik
tk;sxkA dahV dh eki 4-11-16 Hkkx 1 ds dFkukuqlkj
iyLrj laiwfrZ dh eksVkbZ dks NksM+dj dh tk;sxhA

4-1-3 fuEu ds fy,] fdlh Hkh izdkj dh u rks dVkSrh gksxh vkSj uk
gh vfrfjDr fn;k tk;sxkA
1 500 oxZ lsea h rd dh vleku dkV ds fdukjs mnkgj.k
ds fy;s] dfM+;k] iz/kjfu;k;k] xkMZj] [kaHks] kgrhjsa]
dSfp;ka] ?kksfM+;ka] lhf<;ka vkfnA
2 0-1 oxZ ehVj izR;sd rd ds eks[kksa dk cukus esa fdlh
vfrfjDr Je dh eki ugha dh tk;sxhA
uks V % fdlh ,d eks [ ks dk {ks = Qy fudkyus ds fy;s
eks [ ks ds vkdkj es a fdlh iz F kd MkV ;k ns g jh dh
eks V kbZ kkfey gks r h gS A
3 fdlh Hkh izdkj ds tksM+ lknk] iSukeh] vojks/kh] VkaxM+]
[kkapsnkj vkfnA
4 lkaps] Nsnh lkapsa] i[[ks] Qyd] xksy ;k frdksus dkaVs]
xqfj;k] rFkk pkSM+kbZ esa 10 lseh ;k ifjf/k esa 15 lseh ds
[kkaps o i[kA
5 MV~V]s dVkos] myV fdukjs] xksy fdukjs] laxe] Hkjkos vkfnA
6 nhokj nkls rFkk leku 10 lseh xgjkbZ rd dsA
7 NksVh fjfDr;ka tSlh fd fuEu vkd`fr;ksa esa Nk;k okys Hkkx
laiw.kZ tSls A B ekis tk;saxs tc ;g izR;sd dkV esa
40 oxZ lseh ls vf/kd u gksaA ;fn og 40 oxZ lseh ls
vf/kd gS rks fokq+) ekik tk;sxkA 6 o 7 dh vkd`fr;ksa
ds fok; esa ch rFkk ch dh vkSlr yh tk;sxhA
NoteOther sections (including spandrel steps) shall uksV% vU; dkVsa] pki Lda/k lfgr fokq} ekih tk;saxhA
be measured net.
(8) The volume occupied by reinforcement;
(9) The volume occupied by drainage/water pipes,
conduits, etc., not exc. 100 sq. cm each in cross
sectional area. (Refer Fig. 4.1.3 set at the end of
Section 4)

4.1.4 Hollow blocks shall be measured without making


any deduction for hollows.
4.1.5 Pilasters, buttresses, plinth courses, string courses
and similar projections beyond the general surfaces
of walls shall be measured and included with the
wall.

8 izoyu }kjk ?ksjk x;k ifjek.k


9 frjNs dVkbZ {ks= esa 100 oxZ lseh- ls vuf/kd ds ty
fudkl@ikuh ds uyksa] ufy;ksa vkfn }kjk ?ksjs x;s
ifjekiA [kaM ds var es fp= la- 4-1-3 ns[ksa
4-1-4 iksys [k.Mksa dh eki iksyksa dh fdlh dVkSrh ds fcuk dh tk;sxhA
4-1-5 nhokj dh lkekU; lrg ls ijsfHkfk LrEHk] iqkrs lgkjs dqlhZ
jn~ns] fudlk jn~ns rFkk leku iz{ksi.kksa dks ekik tk;sxk rFkk
nhokj esa kkfey fd;k tk;sxkA

35

SECTION 4

SECTION 4 CONCRETE
[k.M 4 dahV
SPECIAL CONDITIONS Contd..
foksk krsZ& tkjh ..
4.1.6 Beams shall be measured from face to face of
columns and shall include haunches, if any,
between the columns and beams. The depth of the
beams shall be measured from the bottom of the
slab to the bottom of the beam, taking the floor or
roof slab as running continuously over the beam.
In the case of inverted beam, the depth of beams
shall be measured from top of slab to top of beam.
4.1.7 Columns shall be measured from the top of the
column base to the underside of the first floor slab
and subsequently from top of floor slab to bottom of
floor or roof slab above as the case may be. The flare
of the column shall be included with the column.
4.1.8 Measurement of chajjas shall be inclusive of the
bearing. Where the chajja is combined with lintel,
beam, etc., it shall be measured as clear projection.
4.1.9 Whenever vertical parapet/fins and chajjas/roof
slabs are combined, the chajjas/roof slabs shall be
measured through.
4.2 Rates
4.2.1 The rates generally include for:

4-1-6 /kjfu;ksas che dh eki] LrEHkksa ds vkeus lkeus ls dh tk;sxh


rFkk ;fn /kjuh o LrEHk ds chp esa dksbZ iqBVk gS rks mls
kkfey fd;k tk;sxkA /kju dh xgjkbZ] ifV;k ds ry ls
/kju ds ry rd ekih tk;sxh] QkZ ;k Nr dh ifV;k tks
/kju ds ekeys esa] che dh xgjkbZ ifV;k ds khkZ ls che ds
khkZ rd ekih tk;sxhA
4-1-7 LrEHkksa dh eki LrEHk vk/kkj ds khkZ ls igyh eafty dh
ifV;k ds uhps rd dh tk;sxh rFkk rnuUrj QkZ ds ifV;k
rd tSlh Hkh fLFkr gks eki dh tk;sxhA LrEHk ds mHkkj dks
LrEHk esa kkfey fd;k tk;sxkA
4-1-8 NTtksa dh eki /kkjd lfgr gksxhA tgka NTtk ljny ;k
/kju vkfn ls tqMk+ gks ogka LiV fuis{k ds :i esa ekik tk;sxkA
4-1-9 tc dHkh Hkh [kM+h eqMjs@
a ia[k o NTtk@Nr dh ifV;k tqMh+
gksa rks NTts@Nr dh ifV;k dh vkjikj esa eki gksxhA

4-2 njs a
4-2-1 njksa esa lkekU;r% fuEu kkfey gksrs gSaA
(1) All removing, hoisting, lowering, etc., required 1
fdlh Hkh izdkj dh dhV dks cukus ds Bh;sLFkku ls dk;Z
in order to convey concrete of any description
esa iz;ksx ds okLrfod LFkku rd igaqpkus ds fy, vko;d
from the banker to the actual place of
<qykbZ] mBkbZ] fxjkbZ vkfn lHkh dk;ZA
incorporation in the work.
2
dahV dks tekus ds ckn mlds iDdk gksus rd dahV dks vPNh
(2) Keeping concrete well wetted during the curing
period after depositing and protecting it in
rjg ls xhyk j[kuk rFkk bls ekSle dh rhozrk ls cpkukA

extreme weather conditions.


(3) Incorporating integral water proofing compound
in the manner specified by the manufacturer and
in the proportions indicated. The rates do not
include for supply of integral water proofing
compound, which is supplied by the Contractor,
shall be paid for, at Supplied only" rates.
(4) Finishing the exposed surfaces of concrete to a
fair and even surface as in 4.11.16.2(a),(c)&(d)
(Part I).
(5) Small linear and incidental labours as
described under Measurements in 4.1.3(4) and
4.1.3(5) including use of forms or moulds except
where a separate item exists.
(6) Bedding and pointing wall plates in or on walls
and bedding roof tiles and corrugated sheets
in or on walls solidly in cement mortar 1:3 and
making good.
(7) Building in or cutting and pinning in with
cement mortar 1:3 ends of joists, beams, etc.,
and making good.
(8) Forming
joints
mentioned
Measurements in 4.1.3(3).

fuekZrk }kjk fufnZV fof/k ls rFkk crk;s x;s vuqikr esa


tylg feJ.k dk lekosk djukA njksa esa tylg feJ.k dh
vkiwfrZ kkfey ugha gS tks Bsdsnkj }kjk iwfjr gksrh gS rks
**dsoy laiwfrZ** dh njksa esa Hkqxrku gksxkA

krZ 4-11-16-2,]lh vkSj Mh Hkkx 1 ds vuqlkj dahV dh


ckgjh lrgksa dks lery o ifjd`r djds laiwfrZ djukA

eki ds vUrxZr 4-1-3 4 o 4-1-3 5 esa dgs vuqlkj iryh


ykbusa Mkyuk o vkdfLed JfedrFkk lkapksa ;k [kkapksa dk iz;ksx
djuk flok; mlds tgka blds fy, vyx ls en fo|eku gksA
nhokj esa ;k nhokj ij nhokj ifV~Vdk;sa yxkuk o Vhi djuk
rFkk lhesaV ds 1%3 ds elkys ls Nr dh Vkbysa o iukjhnkj
pn~njsa nhokj esa ;k nhokj ij yxkuk o Bhd djukA
dfM+;ks]a /kjfu;ksa vkfn ds fdukjksa dks lhesVa ds 1%3 ds elkys
ls cukuk] dVkbZ djuk o uksd cukuk rFkk mUgsa vPNk
cukukA
eki ds vUrxrZ 4-1-3 3 esa crk;s vuqlkj tksM+ksa dh jpuk
djukA
ifjdYi feJ.k dahV ds ifjdYiu dh dherA

under

(9) Cost of designing the design mix concrete in


case of design mix concrete.

36

SECTION 4

SECTION 4 CONCRETE
[k.M 4 dahV
SPECIAL CONDITIONS Contd..
foksk krsZ& tkjh ..
4.2.2

4.2.3

4.2.4

4.2.5

4.2.6
4.2.7

4.2.8

Formwork for all cast-in-situ concrete, unless


otherwise mentioned, shall be measured separately
under the appropriate items in Section 7Woodwork
(Carpenters Work).
Precast Concrete Block Masonry: The rates for precast
concrete block masonry shall include for all the
provisions of Special Condition 5.2 for brick work to
the extent applicable.
Reinforcement shall be measured separately as
Supplied and Fixed under appropriate items of
Section 10.Steel and Iron work, but no extra shall be
allowed for concrete.
The rates for concrete items do not include for cooling/
heating concrete in a special manner by any special
process. The rates, however, include for taking
precautions for concreting in extreme weather conditions.
Unless special provision is made for circular/curved
work, the rates shall include for circular work and
curved work also.
Underwater Concreting: The rates for concrete work shall
also apply to underwater concreting subject to the
enhancement of rates as provided in General Rules
1.14. Any cement incorporated in the concrete over
that required if the mix is placed in dry condition; as
ordered by the GE in writing; shall be paid for at
Supplied only rates.
Unless otherwise specifically mentioned, the rates of
concrete items are for volumetric/nominal mix
concretes. The rates of design mix concretes shall be
arrived at after adjustment of rate difference as per rates
of mixed cement concrete delivered on banker.

4.2.9

Rates of design mix concrete items will apply to mix


designed as per IS-456. No adjustment shall be made
for variation in cement/aggregates ratios.
4.2.10 The rates of concrete/RCC mentioned below against
different item of SSR shall be increased by 15% of the
rate of design mixed cement concrete delivered on
bunker for RMC.
4.2.11 Rate of RMC will be applicable only for concrete
produced from automatic batching plant of capacity
more or equal to 22 Cum/hour or purchased and
brought at site in transit mixer from specified
manufacturer of RMC. The rate RMC shall include for
any admixture required, loading, transportation and
pumping etc. complete.

4-2-2 lhVw esa dahV izoyu dk jpuk dk;Z tc rd fd vU;Fkk of.kZr u


gks] [k.M 7 ydM+h dk dk;Z c<+bZ dk dke dh mi;ZqDr en ds
vUrxZr izFkd ekik tk;sxkA
4-2-3 iwoZ fojfpr dahV dh ifV;ksa dh fpukbZ % iwoZ fojfpr dahV dh
ifV;ksa dh fpukbZ dh njksa esa foksk krZ 5-2 ds bZV ds dk;Z ds izkz o/kku
O;ogkfjd lhek rd ykxw gksx
a As
4-2-4 izoyu dk;Z izFkd :i ls] [k.M 10 dh yksgk o bLikr dk;Z dh
mi;qDr njksa ds vUrxZr ekik tk;sxk] fdUrq dahV ds fy;s dqN
Hkh vfrfjDr ns; ugha gksxkA
4-2-5 dahV dh enksa dh njksa esa dahV dks fdlh foksk izfd;k }kjk foksk
i)fr ls BaMk djuk@xeZ djuk kkfey ugha gSA njksa esa fQj Hkh
ekSle dh rhozrk ls iwoZ cpko mik; djuk kkfey gSA
4-2-6 tc rd fd xksykdkj@oxkZdkj dk;ksZ ds fy;s foksk izko/kku ugha
fd;k tkrk] rks njsa xksydkj @ oxZdkj dk;ksZ dks Hkh lekfgr djsx
a hA
4-2-7 ikuh ds vUnj dahV dk;Z% dahV dk;Z dh njsa] ikuh ds vUnj
dahV dk;Z ij Hkh ykxw gksxh okrsZ lkekU; fu;e 1-14 ds izko/kku
ds vuqlkj njksa es c<+ksrjh dh tk;A ;fn nqxZ vfHk;ark ds fyf[kr
vknsk ds vuqlkj] fu/kkZfjr ek=k ls vf/kd lhesaV dahV esa
feyk;k tkrk gS] feJ.k dks lw[kh voLFkk esa j[kk tkrk gS] rks
mldk **dsoy vkiwfrZ** dh njksa esa Hkqxrku fd;k tk;sxkA
4-2-8 tc rd fd vU;Fkk foksk #i ls of.kZr ugh gks] dahV enksa dh
nj ?kuekih@ukeh;s feJ.k dahV ds fy, nh xbZ gSA ifjdYi
feJ.k dahV dh njsa izkIr djus ds fy, ?kuekih@ukeh; vkSj
ifjdYi cadj ij fcNkbZ xbZ fefJr lhesaV dh njksa esa varj dk
lek;kstu fd;k tk;sxkA
4-2-9 ifjdYi feJ.k dahV ds enksa dh njsa Hkk ek& 456 ds vuqlkj
ijfdYi fd;s x;s feJ.kksa ds fy, ykxw gksxhA lheasV@feykok ds
vuqikr esa ifjorZu ds fy, dksbZ lek;kstu ugha gksxkA

LIME CONCRETE IN FOUNDATIONS

uhoksa esa pwuk dahV dk;Z


The rates for item 04003 include for selecting bricks or
brick bats, breaking and grading by the contractor.
PER CUBIC METRE

Lime mortar
1:2

en 04003 dh njksa esa bZVksa ;k jksM+ks dk Bsdsnkj }kjk p;u djuk rksM+uk
o eki esa j[kuk kkfey gSA
Lime mortar
1:3

iz f r ?ku ehVj

pwuk elkyk 1%2 pwuk elkyk 1%3


04001 Lime concrete with 40 mm graded

stone aggregate
04002 Ditto, but with brick aggregate
04003 Ditto, but with bricks supplied by the

M.E.S. free of charge

Rs.
1818.50
1765.70

Rs.
1681.90
1629.10

1893.75

1162.10

04001 40 feeh dh iRFkj jksMh+ feykos dh pwuk dahV


04002 mi;qZDr] fdUrq bZV jksM+h feykos ds lkFk
04003 mi;qZDr] fdUrq ,e bZ ,l }kjk fukqYd nh xbZ
bZVksa ds lkFk

37

SECTION 4

SECTION 4 CONCRETE
[k.M 4 dahV
MIXED CEMENT CONCRETE DELIVERED ON BUNKER

cadj ij fcNkbZ xbZ fefJr lhesaV dahV


(a)

(b)

(c)

(d)
(e)

The following rates are for the various types and


grades of concrete, mixed and supplied only and
shall form the basis for price adjustment when
variations from the standard mixes are indicated.
Where bricks are supplied by M.E.S., free of charge,
the Contractor shall select, break, screen and grade
the aggregate.
The rates for all items of concrete work throughout
the SSR are based on the prices contained in column
6 of the table below for concrete made with graded
coarse aggregate. Where brick coarse aggregate is
used, the SSR rates shall be adjusted in accordance
with rates in columns 7 & 8.
The quantity of concrete shall be taken as the net
volume only of finished work.
Rates for cement concrete made with brickcoarse
aggregates are applicable for volumetric mixes only.

fuEu njsa fofHkUu izdkj o Js.kh dh dahV dh dsoy vkiwfrZ djus


o feykus ds fy;s gS]a rFkk tc ekud feJ.kksa eas fofHkUurk vkrh
gS rks mldh ykxr dk lek;kstu djus esa ;g vk/kkj cusxkA

[k

tgka bZVksa dh ,e bZ ,l }kjk fukqYd vkiwfrZ gksrh gS ogka


Bsdsnkj mudk p;u] rqM+kbZ] NaVkbZ o feykok cuk;sxkA

,l ,l vkj esa nh xbZ dahV dh enksa dh lHkh njsa uhpsa nh


xbZ rkfydk ds dkye 6 esa nh xbZ dahV ds feykos lfgr
dh njksa ij vk/kkfjr gSa tgka bZaVksa ds feykos iz;ksx fd, tkrs
gSa ogka dkye 7 o 8 dh njksa ls lek;kstu gksxkA

?k

dahV dh ek=k] dsoy laiw.kZ dk;Z dh fokq ?kuRo ds :i esa


yh tk;sxhA
bZVa ds eksVs feykos dh lheaVs dahV ds njsa dsoy ?kuRo okys
feykos ds fy;s gSaA

M+

izfr ?ku ehVj

PER CUBIC METRE


Type, grade & mix of cement concrete

uewuk Js.kh rFkk lhaesV dahV feJ.k


Item

Type

Graded

Mix (by volume)

en

uew u k

oxhZ d ` r

feJ.k ek=k

Nominal size
of graded
coarse
aggregate in
mm

oxhZd`r eksVs
feykos dh
ukih; eki
feeh esa
1

Portland cement concrete with

iksVZySaM lhaesV dahV lkFk esa


Graded
Brick
Brick coarse
coarse
coarse
aggregate made
aggregate aggregate out of bricks
supplied by MES
oxhZ d ` r
bZaV dk
free of charge
eks V k
eks V k

feykok
6
Rs.

Volumetric and nominal mix concretes (Items 04004 to 04015)

feJ.k
7
Rs.

,e bZ ,l dh fu'kqYd
bZaVksa dk eksVk feJ.k
8
Rs.

/kuekih vkSj ukeh;s feJ.k dahV njs 04004 ls 04015

04004 A

M-20

1:11/2:3

12.5

3281.10

04005 A

M-20

1:11/2:3

20

3261.30

04006 A

M-20

1:11/2:3

40

3207.10

04007 B

M-15

1:2:4

12.5

2775.70

04008 B

M-15

1:2:4

20

2751.00

04009 B

M-15

1:2:4

40

2701.70

04010 C

M-10

1:3:6

12.5

2288.90

04011 C

M-10

1:3:6

20

2263.30

04012 C

M-10

1:3:6

40

2212.30

2161.10

1701.10

04013 D

M-7.5

1:4:8

40

1945.10

1893.40

1428.10

04014 E

M-5

1:5:10

40

1766.70

1715.00

1249.70

04015 F

1:7:12

40

1654.60

1569.50

1120.00

38

SECTION 4

SECTION 4 CONCRETE
[k.M 4 dahV
MIXED CEMENT CONCRETE DELIVERED ON BANKER Contd..
cadj ij fcNkbZ xbZ fefJr lhesaV dahV tkjh..
Design mix concretes (Items 04016 to 04024)
1

ifjdYi feJ.k dahV njsa 04016 ls 04024

04016

M-20

12.5

3118.70

3110.20

04017

M-20

20

3093.30

3063.80

04018

M-20

40

3042.50

3034.00

04019

M-25

12.5

3285.80

3277.20

04020

M-25

20

3260.40

3230.80

04021

M-25

40

3209.50

3180.00

04022

M-30

12.5

3452.80

3444.20

04023

M-30

20

3427.40

3397.80

04024

M-30

40

3376.50

3368.00

CEMENT CONCRETE IN FOUNDATIONS, SURFACE DRAINS, WALLS, MASS CONCRETE, RETAINING


WALLS, ETC.

lhesasV dahV] uhoksa] ijh ukfy;ksa] dqvksa] O;kid :i esa] /kkjd nhokjksa vkfn esa
Extra labour in forming channels shall be paid for in addition
under items 04079 & 04080 and deduction from the volume
of concrete shall be made for the channel opening.
PER CUBIC METRE

04025 Cement concrete


in foundations,
filling and mass

concrete
04026 Cement concrete in
surface channels

and drains
04027 Ditto in walls or
retaining walls,
any thickness, size
or shape including
pilasters, buttresses
columns, pillars,
boundary pillars
and
posts
(including caps and

bases)

iz.kky pSuy dh cukoV esa Qkyrw Je dk HkqXkrku en 04079 o


04080 ds varxZr vfrfjDr fd;k tk;sxk rFkk iz.kky ds eq[k ds fy;s
dahV esa ls dVkSrh dh tk;sxhA
izfr ?ku ehVj

Type B2
1:2:4
(40 mm
graded
aggregate)

Type C2
1:3:6
(40 mm
graded
aggregate)

Type D2
1:4:8
(40 mm
graded
aggregate)

Type E2
1:5:10
(40 mm
graded
aggregate)

Type F2
1:7:12
(40 mm
graded
aggregate)

ch2 uewuk
1%2%4 dqy
40 feeh
feJ.k

lh 2 uewuk
1%3%6 dqy
40 feeh
feJ.k

Mh 2 uewuk
1%4%8 dqy
40 feeh
feJ.k

bZ 2 uewuk
1%5%10 dqy
40 feeh
feJ.k

,Q 2 uewuk
1%7%12 dqy
40 feeh
04025 uhoksa] Hkjkoksa rFkk O;kid
feJ.k
:i esa lhesaV dahV
Rs.

Rs.

Rs.

Rs.

Rs.

3062.50

2579.00

2303.30

2124.90

3087.20

2648.80

2337.60

2166.30

1965.80

2054.20

04026 mi;qZDr] ijh iz.kkyksa o


ukfy;ksa esa

04027 mi;qZDr] fdlh Hkh eksVkbZ]


uki ;k vkdkj ds fHkUu
LrEHkks]a Vsdks]a LrEHkks]a [kaHkks]a
lhek [kaHkksa o [kwVksa lfgr
nhokjksa] /kkjd&nhokjksa esa
'kh"kZ o vk/kkj lfgr
3280.00

2790.20

2523.10

2344.80

2232.70

39

SECTION 4

SECTION 4 CONCRETE
[k.M 4& dahV
CEMENT CONCRETE CAST-IN-SITU
LoLFkku fojfpr lhesaV dahV
(a) The rates include for use of formwork (straight or curved). d njksa esa lajpuk likV ;k o djuk 'kkfey gSA
(b) Concrete items if so indicated, shall be reinforced. [k ;fn ,slk dgk tkrk gS rks dahV izofyr dh tk;sxhA
Reinforcement shall be measured separately.
izoyu izFkd ekik tk;sxkA
TypeB0
1:2:4
(12.5mm
graded
aggregate)

PER CUBIC METRE

uewuk ch vks
1%2%4 dqy
12-5 feeh
04028 Providing, cement concrete in roof feJ.k

Type B1
1:2:4
(20 mm
graded
aggregate)

Type C1
1:3:6
(20 mm
graded
aggregate)

uewuk ch 1
1%2%4 dqy
20 feeh
feJ.k

uewuk lh 1
1%3%6 dqy
20 feeh
feJ.k

kerbs or mud stops, rounded or

chamfered on edges

Rs.
4110.50

Rs.
3939.90

Rs.
3421.00

04029 Ditto, in lintels upto 1.5m clear


span, cills, steps; seismic
and other similar bands,
plinth courses, string courses,
lacing courses, parapets and
railings upto 60 cm in height,
copings, kneelers, apex stones,
bed plates, kerbs not provided
for in Item 04028, water
troughs and the like including
weathering, slightly rounded
or chamfered angles and

throating, as directed

4169.10

4144.40

3656.70

izfr ?ku ehVj

04028 Nr ds fdukjksa ;k Nr ds xksy ;k


frjNs fdukjksa ij lhesaV dahV

Mkyuk
04029 mi;qZDr] 1-5 eh- ds Li"VikV rd
fyVayksa] ifV;ksa] lhf<+;ksa HkwdEih;
o vU; leku iVVksa] dqlhZ jn~ns]
fpukbZ jn~ns] ca/kd jn~ns eqMsjksa o
60 lseh dh jsfyax] eqMsj Vsdfu;ksa
f'k[kj iRFkjks]a vk/kkj iV~Vks]a mikarks(a
ftudk en 04028 esa izko/kku ugha
gS] ikuh dh Vafd;ka rFkk leku(
<ykuks]a FkksMs+ xksy ;k i[knkj dks.k
rFkk funs'kkuqlkj [kkaps

PRECAST CEMENT CONCRETE WORK

(a)

(b)
(c)
(d)
(e)

(f)
(g)

iwoZ fojfpr lhesaV dahV dk;Z


IN MASONRY, LINTELS, SLABS, ETC.
fpukbZ] fyaVy] ifV;k vkfn esa
The rates include for the use of forms, moulds or ma- d njksa esa Qjeka]s [kkapksa ;k e'khuh ;k [kkapksa dk iz;ksx djuk 'kkfey
chine moulds and setting the blocks, slabs, etc.
gS rFkk pkSds ifV;kN fcBkuk o iw.kZ djuk] vUn:uh Hkkx tksMk+ as
complete including raking back the joints of the
dks dke ds nkSjku Vhi djus ds fy, [kqjpuk de ls de 10
internal faces (at least 10 mm) for pointing as the work
feeh ;k lkQ likV tksM+ksa ds lkFk laiwfrZ djukA
proceeds or finishing with neat flush joints.
[k
iw
oZ fojfpr pksds yxkus ds ckn tksM+ksa dks 'kkfey djds dk;Z
Precast block construction shall be measured as set in
dks ekik tk;sxkA
the work, the joints being included in the measurement.
Building blocks exceeding 10 cm on bed shall be x ry ij 10 lseh- ls vf/kd ds cus pksdksa dks ?ku ehVj esa ekik
measured in cubic metre; those n. exc 10 cm on bed
tk;sxk rFkk 10 lseh ls vuf/kd pksdksa dks cuh ifV;ksa ds :i
shall be measured as building slabs in square metre.
eas] oxZ ehVj esa ekik tk;sxkA
Hollow block construction shall be kept separate; no ?k [kks[kys pksdksa ds fuekZ.k dks vyx j[kk tk;sxk] pksdksa ds
deduction shall be made for the hollows in the blocks.
[kks[kys ds fy;s dksbZ dVkSrh ugha gksxhA
The rates for building blocks and slabs allow for the M- pksdksa o ifV;ksa dks cukus dh njsa vko';d dksfu;k pksds] iD[ks
necessary quoin blocks, jamb blocks (plain), closers,
pksds lknk l?ku vkfn rFkk lHkh dVkbZ o Nhtu Hkh o uy]
etc. and also for all cutting and waste and holes (cut
cksYV vkfn yxkus ds fy;s fNnz dkVs x;s ;k cuk;s x;s rFkk
or formed) for fixing pipes, bolts etc. and making good.
mudks Bhd djukA
Precast cement concrete item shall be reinforced, where p lhesaV dahV dh oLrq;sa tgka dgk tk; izofyr dh tk;saxhA
indicated. Reinforcement shall be measured separately.
izoyu vyx ls ekik tk;sxkA
The rates for cement concrete block masonry do not N lhesaV pksdksa dh fpukbZ dh njksa esas Hkkjrh; ekud fofuZns'kuksa esa
include for various tests as laid down in the relevant
dgs x;s lacfU/kr tkap dk;Z 'kkfey ugha gS flok; yk{kf.kd
IS specifications except testing for characteristic
'kfDr] ty'kks"k.k o pksds dh l?kur ds tkap dk;ZA
strength, water absorption and block density.

40

SECTION 4

SECTION 4 CONCRETE
[k.M 4& dahV
PRECAST CEMENT CONCRETE WORK Contd..
iwoZ fojfpr lhesaV dahV dk;Z& tkjh
tkjh..
(h) In the case of louvres and jallies, thickness refer to the
thickness of louvres and jallies and not to the
thickness of frame. The superficial areas of louvres
and area of opening filled by jally shall be measured
in the case of louvres and jallies.
(j) The filling of hollow block masnory with sand or
concrete shall be paid for as under: (1) Sand at Supplied only rates; and
(2) Cement concrete at the rates for Mixed cement
concrete delivered on banker.
PER CUBIC METRE

t f>yfey ;k tkyh ds ekeys esa eksVkbZ dk vFkZ f>yfey ;k


tkyh dh eksVkbZ ls gSa u fd se dh eksVkbZ ls f>yfey dk ijh
{ks= o tkyh ls <dk {ks=] f>yfey o tkyh ds ekeys esa ekik
tk;sxkA
> [kks[kys pksdksa dh fpukbZ esa ckyw ;k dahV dh HkjkbZ dk fuEu
izdkj Hkqxrku gksxk%&
1 ckyw dk ^^dsoy laiwfrZ** dh njksa ij rFkk
2 lhesaV dahV dk ^^cdaj esa Mkyus okyh feyh gqbZ lhesaV
dahV** dh njksa ij
Set in cement
Except
Except
izfr ?ku ehVj

Set in cement
mortar 1:4

blocks or
slabs set
in cement
mortar
1:4

mortar 1:6

lhesaV elkys esa


fLFkj 1%4

lhesaV elkys esa


fLFkj 1%6

pksd]s
ifV;k
Type B1 Type C1 Type B1 Type C1 jfgr]
1:2:4
1:3:6
1:2:4
1:3:6
lhesVa
(20mm
(20mm
(20mm
(20mm
elkyk
graded
graded
graded
graded
aggregate aggregate aggregate aggregate 1%4
uewuk ch1 uewuk lh1 uewuk ch1 uewuk lh1
20 feeh 20 feeh 20 feeh 20 feeh
dqy
dqy
dqy
dqy
feJ.k
feJ.k
feJ.k
feJ.k
1%2%4
1%3%6
1%2%4
1%3%6
Precast cement concrete

iwoZ fopfjr lhesaV dahV

04030 Pre-cast cement


concrete block
masonry with
solid blocks, exc. 10
cm in width and
setting in mortar,

complete

blocks or
slabs set
in cement
mortar
1:6

pksd]s
ifV;k
jfgr]
lhesVa
elkyk
1%6

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

4021.60

3536.50

3959.00

3469.00

566.50

498.90

04030 iwoZ fojfpr lhesVa


dahV ds 10 lseh
ls vf/kd pkSMs + Bksl
pksdksa dh elkys
esa fpukbZ djds
laiwfrZ

PRECAST HOLLOW CONCRETE BLOCKS


iwoZ fojfpr [kks[kys dahV pksds
PER CUBIC METRE

Set in cement
mortar 1:4

izfr ?ku ehVj

Set in cement
mortar 1:6

lhesaV elkys esa


fLFkj 1%4

lhesaV elkys esa


fLFkj 1%6

Precast cement concrete

iwoZ fopfjr lhesaV dahV


Type
1:2:4
using
(16mm
graded
aggregate)
as per IS
383

04031 Precast cement


con-crete hollow
block masonry
exc. 10 cm in
width and setting
in
mortar

complete

uewuk 1%2%4
16 feeh
dqy feykok
vkbZ ,al
383
vuqlkj

Type
1:3:6
using
(16mm
graded
aggregate)
as per IS
383

uewuk 1%3%6
16 feeh
dqy feykok
vkbZ ,al
383
vuqlkj

Type
1:2:4
using
(16mm
graded
aggregate)
as per IS
383

uewuk 1%2%4
16 feeh
dqy feykok
vkbZ ,al
383
vuqlkj

Type
1:3:6
using
(16mm
graded
aggregate)
as per IS
383

uewuk 1%3%6
16 feeh
dqy feykok
vkbZ ,al
383
vuqlkj

Except

Except

blocks or
slabs set
in cement
mortar
1:4

blocks or
slabs set
in cement
mortar
1:6

pkSd]s
ifV;k
jfgr
lhesVa
elkyk esa
1%4

pkSd]s
ifV;k
jfgr
lhesVa
elkyk esa
1%6

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

2954.30

2663.80

2886.20

2534.90

566.50

498.90

04031 iw o Z fojfpr
dahV ds 10 lseh
ls vf/kd pkSMs+
[kks[kys pkSdksa dh
fpukbZ dks elkys

esa yxkdj laifw rZ

41

SECTION 4

SECTION 4 CONCRETE
[k.M 4 dahV
PRECAST HOLLOW CONCRETE BLOCKSContd..
iwoZ fojfpr [kks[kys dahV pksds&tkjh..
PER CUBIC METRE
04032 Providing precast
ce- ment concrete in
win- dow or door
cills,
lintels,
bressumers, steps,
quoin blocks (for
use with masonry),
string
courses, copings.
kneelers, apex
stones, pier caps,
columns,
posts,
boundary pillars,
bed plates, pintle
blocks, ancho-rage
blocks, bonders
(for stone wallin).
corbels, brackets,
etc. (of any section
indicated), with
plain fair faces,
including chamfers, weatherings,
throat- ing etc. and
setting in mortar
complete with
joints to match
04033 Ditto, but in
landings, cover
slabs (for man holes
etc.)
chullah
hoods, chajjas,
water troughs,
mangers, shelves
and similar articles
with plain faces
PER SQUARE METRE

04034 Providing precast


cement concrete
louvres and jallies,
25mm thick (mea
sured solid), including
all
mould- ings but
excluding frame
(Pre
cast frame
shall be measured separately and
paid for under item

04032)

Set in cement
mortar 1:4

Set in cement
mortar 1:6

lhesaV elkys esa


fLFkj 1%4

lhesaV elkys esa


fLFkj 1%6

Except
blocks or
slabs set
in cement
mortar
1:4

Precast cement concrete

iwoZ fopfjr lhesaV dahV

Type B1
1:2:4
(20mm
graded
aggregate)

Type C1
1:3:6
(20mm
graded
aggregate)

Type B1
1:2:4
(20mm
graded
aggregate)

Type C1
1:3:6
(20mm
graded
aggregate)

uewuk ch1
1%2%4
20 feeh
dqy
HkjkbZ

uewuk lh1
1%3%6
20 feeh
dqy
HkjkbZ

uewuk ch1
1%2%4
20 feeh
dqy
HkjkbZ

uewuk lh1
1%3%6
20 feeh
dqy
HkjkbZ

pksd]s
ifV;k
jfgr
lhesVa
elkys
1%4 esa
yxs

Except
izfr ?ku ehVj
blocks or
slabs set 04032 f[kM+dh ;k njoktksa
dh nsgfy;ks]a fyaVyks]a
in cement
mortar
da x w j ks a ] lhf<+ ; ks a ]
1:6
dksfu;ksa pksds fpukbZ

pksd]s
ifV;k
jfgr
lhesVa
elkys
1%6 esa
yxs

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

4817.60

4325.60

4820.00

4303.20

645.80

638.80

4817.60

4325.60

4820.00

4303.20

645.80

638.80

Set in cement mortar Set in cement mortar Except


1:4
1:6
blocks or
lhesaV elkys esa fLFkj lhesaV elkys esa fLFkj slabs set
in cement
1%4
1%6
mortar
Precast cement concrete
1:4
iwoZ fopfjr lhesaV dahV
Type B0
1:2:4
(12.5mm
graded
aggregate)

Type C0
1:3:6
(12.5mm
graded
aggregate)

uewuk ch0 uewuk lh0


1%2%4
1%3%6
12-5 feeh 12-5 feeh
dqy feJ.k dqy feJ.k
Rs.
324.90

Rs.
313.90

Type B0
1:2:4
(12.5mm
graded
aggregate)

Type C0
1:3:6
(12.5mm
graded
aggregate)

uewuk ch0 uewuk lh0


1%2%4
1%3%6
12-5 feeh 12-5 feeh
dqy feJ.k dqy feJ.k
Rs.
324.00

Rs.
312.30

pksd]s
ifV;k
jfgr
lhesVa
elkyk
1%4

Rs.
83.40

Except
blocks or
slabs set
in cement
mortar
1:6

pksd]s
ifV;k
jfgr
lhesVa
elkyk
1%6
Rs.
81.80

esa iz;ksx ds fy,


fpukbZ jn~n]s eqMa js vk/
kkj 'kh"kZ] ca/kd jn~n]s
LrEHkks]a [kEHkksa lhek
[kEHkksas vk/kkj ifV;ks]a
fiUVy [kaM] fLFkjd
[kaM] [kaMd iRFkj
dh nhokj dk;Z ds
fy;s
rk[kks a ]
nhokjfxjh vkfn esa
fdlh Hkh vafdr [kaM
dk iwoZ fojfpr lhesVa
dahV dk;Z rFkk
likV o pedkuk]
iD[kks]a <ykuks]a mijks/
kuksa vkfn lfgr rFkk
tksMk+ s dks elkys ls
feykrs gq, laiwfrZ
djuk
0 4 0 3 3 mi;q Z D r] lks i ku
vkoj.k pksds
esugksy vkfn ds
pwYgs N=] NTts]
ikuh Vafd;ka] 'kSYQksa
rFkk likV lrg
dh leku oLrq,sa

izfr oxZ ehVj

04034 25 feeh eksVs iwoZ


fojfpr f>yfey
;k tkfy;ka Bksl
ekih tk;sx
a h lHkh
x<+kbZ lfgr fdUrq
lkaps jfgr iwoZ
fojfpr lkapk izFkd
ekik tk;sxk rFkk
Hkqxrku en 04032
ds varxZr gksxk

42

SECTION 4

SECTION 4 CONCRETE
[k.M 4 dahV
PRECAST CONCRETE BLOCKS Contd..
iwoZ fojfpr [kks[kys dahV pksds&tkjh..
Set in cement mortar Set in cement mortar Except
1:4
1:6
blocks or
lhesaV elkys esa fLFkj lhesaV elkys esa fLFkj slabs set
in cement
1%4
1%6
mortar
Precast cement concrete
1:4
iwoZ fopfjr lhesaV dahV

PER SQUARE METRE

04035 Add to or deduct


from item 04034
for each 10 mm
thickness or part
thereof, over 25
mm thick

PER SQUARE METRE

04036 Providing
precast cement
concrete solid
building blocks
or
slabs 10cm
thick (with plain
or interlocking
joints as directed)
setting in mortar,
complete, in walls

04037 Ditto, but with 7.5


cm thick solid
blocks

Type B0
1:2:4
(12.5mm
graded
aggregate)

Type C0
1:3:6
(12.5mm
graded
aggregate)

uewuk ch0 uewuk lh0


1%2%4
1%3%6
12-5 feeh 12-5 feeh
dqy feJ.k dqy feJ.k

Type B0
1:2:4
(12.5mm
graded
aggregate)

Type C0
1:3:6
(12.5mm
graded
aggregate)

uewuk ch0 uewuk lh0


1%2%4
1%3%6
12-5 feeh 12-5 feeh
dqy feJ.k dqy feJ.k

Rs.

Rs.

Rs.

Rs.

55.00

52.70

54.30

52.10

pksd]s
ifV;k
jfgr
lhesVa
elkyk
1%4

Rs.
17.20

Set in cement mortar Set in cement mortar Except


1:4
1:6
blocks or
lhesaV elkys esa fLFkj lhesaV elkys esa fLFkj slabs set
in cement
1%4
1%6
mortar
Precast cement concrete
1:4
iwoZ fopfjr lhesaV dahV
Type B1
1:2:4
(20mm
graded
aggregate)

Type C1
1:3:6
(20mm
graded
aggregate)

uewuk ch1 uewuk lh1


1%2%4
1%3%6
20 feeh 20 feeh
dqy feJ.k dqy feJ.k

Type B1
1:2:4
(20mm
graded
aggregate)

Type C1
1:3:6
(20mm
graded
aggregate)

uewuk ch1 uewuk lh1


1%2%4
1%3%6
20 feeh 20 feeh
dqy feJ.k dqy feJ.k

Rs.

Rs.

Rs.

Rs.

519.20

482.80

513.80

472.90

467.00

434.70

461.60

429.30

pksd]s
ifV;k
jfgr
lhesVa
elkyk
1%4

Except
blocks or
slabs set
in cement
mortar
1:6

pksd]s
ifV;k
jfgr
lhesVa
elkyk
1%6
Rs.
16.60

izfr oxZ ehVj

04035 25 feeh ls
vf/kd ds fy,
izR;sd 10 feeh
vf/kd ;k de
eksVkbZ ;k mlds
Hkkx ds fy, en
04034 esa tksMs+ ;k
?kVk;sa

Except
blocks or
slabs set
in cement
mortar
1:6

pksd]s
ifV;k
jfgr
lhesVa
elkyk
1%6

izfr oxZ ehVj

04036 iwoZ fojfpr 10


lseh eksVh lhesaV
dahV ds pksds
;k ifV;k lknk
;k vUr% ik'k tksM+
funs'Z kkuqlkj rFkk
nhokjksa esa elkys
ls yxkdj laifw rZ
djuk

Rs.
178.70

Rs.
173.30

176.00

04037 mi;qZDr] fdUrq


7-5 ls e h eks V s
Bksl Pkksds lfgr
170.70

43

SECTION 4

SECTION 4 CONCRETE
[k.M 4& dahV
PRECAST HOLLOW CONCRETE BLOCKSContd..
iwoZ fojfpr [kks[kys dahV pksds&tkjh..
PER SQUARE METRE

Set in cement mortar Set in cement mortar


1:4
1:6

lhesaV elkys esa fLFkj


1%4

lhesaV elkys esa fLFkj


1%6

Precast cement concrete

iwoZ fopfjr lhesaV dahV

Type
1:2:4
using
(16mm
graded
aggregate)
as per IS
383

Type
1:3:6
using
(16mm
graded
aggregate)
as per IS
383

izfr oxZ ehVj

Type
1:2:4
using
(16mm
graded
aggregate)
as per IS
383

Type
1:3:6
using
(16mm
graded
aggregate)
as per IS
383

Except
blocks or
slabs set
in cement
mortar
1:4

pksd]s
ifV;k
jfgr
uewuk 1%2%4 uewuk 1%3%6 uewuk 1%2%4 uewuk 1%3%6 lhesVa
16 feeh 16 feeh 16 feeh 16 feeh elkyk
dqy feykok dqy feykok dqy feykok dqy feykok
1%4
vkbZ ,al vkbZ ,al
vkbZ ,al vkbZ ,al
383
383
383
383
04038 Providing precast
vuqlkj
vuqlkj
vuqlkj
vuqlkj
cement concrete
hollow block 10cm

thick

Rs.

Rs.

Rs.

Rs.

422.10

395.60

419.40

393.00

Except
blocks or
slabs set
in cement
mortar
1:6

pksd]s
ifV;k
jfgr
lhesVa
elkyk
1%6

Rs.
166.00

Rs.
163.40

04038 iwoZ fojfpr lhesVa


dahV ds 10 lseh
ls vf/kd eksVs

[kks[kys pksds

REINFORCED CEMENT CONCRETE WORK (NOMINAL MIX)


izofyr lhesaV dahV dk;Z ukeh; feJ.k
(a) For floor finishing, etc., see Section 13Floor Finishes
and Pavings.
(b) Concrete surrounds to rolled steel joists or beams, steel
stanchions, etc., shall be paid as reinforced concrete.
The structural steel work shall be measured
separately under Section 10Steel and Ironwork, and
its volume shall not be deducted from the volume of
the concrete in which it is embedded. However, where
boxed stanchions, etc. are encased in concrete, the
volume of boxed up cavity shall be deducted.
(c) Any wire netting in wrapping to the steel work shall
be measured separately, under Section 9Builder's
Hardware.
PER CUBIC METRE
Reinforced cement concrete (nominal
mix) in:04039 Foundations, including rafts,
footings, foundation beams;
plinth beams; bases for
columns, etc.; basement slabs,
under-reamed piles and mass
concrete

d Q'kkZs dh laifw rZ vkfn ds fy,] [kaM 13& ns[ksa Q'kZ laifw rZ rFkk
fcNkouA
[k csfYyr bLikr dh dM+h ;k /kju] bLikr LFkk.kqd esa fy- iVh
dahV dk Hkqxrku izofyr dahV ds :i esa gksxkA lajpuk
bLikrh fuekZ.k izFkd :i ls [k.M 10& bLikr rFkk yksgs ds
dk;Z ds varxZr ekik tk;sxk rFkk bldk vk;ru] dahV ds
vk;ru ftlesa yxk gS] esa ls ugha ?kVk;k tk;sxkA fQj Hkh tgka
isVh LFkk.kqd vkfn dahV ls cus gSa rks isVh dk vk;ru ?kVk;k
tk;sxkA
x bLikr dk;Z dks cka/kus essa yxs rkj dks [k.M 9& fuekZ.k dh
/kkrq lkexzh ds vUrxZr izFkd ekik tk;XkkA

Cement Concrete

lhesaV dahV

TypeB0 1:2:4
Type B1 1:2:4
(12.5mm graded (20 mm graded
aggregate)
aggregate)

uewuk ch vks 1%2%4 uewuk ch 1 1%2%4


12-5 feeh dqy 20 feeh dqy
feJ.k
feJ.k
Rs.
3133.20

Rs.
3101.50

izfr ?ku ehVj


buesa izofyr lhesVa dahV ukeh; fe=.k%&
04039 uhoksa] jSVksa] iknksa] uhoa /kju] dqlhZ /
kju] LrEHkksa ds vk/kkj vkfn lfgr
rg[kkus ds iV~Vs] v/k os/ku LFkw.k
rFkk LFkwy dahV

44

SECTION 4

SECTION 4 CONCRETE
[k.M 4& dahV
REINFORCED CEMENT CONCRETE WORK(NOMINAL MIX)-Contd........

izofyr lhesaV dahV ds dk;Z ukeh; feJ.k&tkjh


izfr ?ku ehVj

PER CUBIC METRE


Cement Concrete

lhesaV dahV

Reinforced cement concrete (nominal


mix) in:04040 Walls, retaining walls, basement
walls, ballast walls and the like;
any thickness; above top of
footings; including attached

pilaster and buttresses


04041 Slabs supported on walls,
beams and columns in floors,
roofs, landings, balconies,
canopies, deck slabs and in

shelves and the like

04042 Chajjas
04043 Beams, cantilevers, bressummers, lintels over 1.5m span
04044 Columns, pillars, piers, posts

and struts
04045 Chullah hoods; stairways
(except spiral staircases)
including steps (square
or
spandril),
string pieces,
carriages, etc., complete, any
section straight or winding,
but excluding landings; RCC

water tanks upto 1500 litres

TypeB0 1:2:4
Type B1 1:2:4
(12.5mm graded (20 mm graded
aggregate)
aggregate)

uewuk ch vks 1%2%4 uewuk ch 1 1%2%4


12-5 feeh dqy 20 feeh dqy
feJ.k
feJ.k
Rs.
3617.60

04040 nhokjks]a /kkjd nhokjks]a rg[kkuksa dh nhokjks]a s


fxV~Vh nhokjksas rFkk leku fdlh eksVkbZ
dh] iknksa ds 'kh"kZ ds ij] rFkk lkFk yxs
fHkfk LrEHk o iq'krs lfgr

3456.40

3429.80

04041 nhokjks]a ij vk/kkfjr ifV;ka /kju o


dM+h Q'kks]aZ Nrks]a s /kjkryk]sa okydfu;ka]s
Nkofj;ks]a ikVu ifV;ksa rFkk 'kSYQ o
leku esa

3798.50

3773.80

Rs.
3642.30

3676.00

3651.30

3817.70

3793.00

3807.20

3782.50

04046 Spiral staircases (including

landings)
04047 Arches

4987.20

4962.50

3814.30

3791.60

04048 Domes, vaults, shell roofs, arch

ribs and folded plates

3878.50

3853.80

04050 Well steining and well curbs

3711.70
3596.10

3620.40
3571.40

04051 Fins, fascias, louvres, parapets,


and railings exc. 60cm in
height, newels, balustrade, and

the like

3752.90

3728.20

65.50

65.50

04049 Chimneys and shafts

04052 Extra over item 04039, 04040


& 04044 for doing work in
water retaining structures

buesa izofyr lhesVa dahVukeh; feJ.k%&

04042 NTtksa esa


04043 1-5 eh ls vf/kd ds vk;ru ds /kju

izkl] ikVdM+h] fyaVy


04044 LrEHkks]a [kEHkks]as ik;ks]a [kwVa ksa o Vsdksa esa
04045 pwYgs N=d] lh<+h ds iFkksa ?kqekonkj
lh<+h ds vfrfjDr ikn lfgr oxhZ;
;k lfiZy yM+h Hkkx] dkBh vkfn
lai.w kZ] fdlh Hkh lh/kh ;k ?kqeko lfgr
vk/kkj ry] izofyr lhesaV dahV
ds ikuh ds 1500 fyVj rd ds gkSt

04046 lfiZy lhf<+;ksa lksiku lfgr


04047 esgjkosa
04048 xqEcn] pkisa] dks'kh; Nr] i'kqZdk

MkV o ca/kh ifV~Vdk;sa


04049 fpefu;ka o 'kSV
04050 dq;sa dh txr o dq;sa ds o ?kqeko
04051 fQu ik[ks eq[k iV~Vh] f>yfey eqM
a js s
o taxys vkfn 60 lseh ls vf/kd
mpakbZ ds] lksiku LrEHk] oY;kyEc

taxyk rFkk leku


04052 ty /kkjd lajpukvksa esa dk;Z ds
fy, en 04039] 04040 o 04044 esa

tksMs+

45

SECTION 4

SECTION 4 CONCRETE
[k.M 4& dahV
REINFORCED CEMENT CONCRETE WORK(Design Mix)

izofyr lhesaV dahV ds dk;Z ifjdYi feJ.k dahV


(a) For floor finishing, etc., see Section 13Floor Finishes
and Pavings.
(b) Concrete surrounds to rolled steel joists or beams, steel
stanchions, etc., shall be paid as reinforced concrete.
The structural steel work shall be measured
separately under Section 10Steel and Ironwork, and
its volume shall not be deducted from the volume of
the concrete in which it is embedded. However, where
boxed stanchions, etc. are encased in concrete, the
volume of boxed up cavity shall be deducted.
(c) Any wire netting in wrapping to the steel work shall
be measured separately under Section 9Builder's
Hardware.
PER CUBIC METRE

Cement Concrete

Reinforced cement concrete (design


mix)in:04053 Foundations, including
rafts, footings, foundation
beams; plinth beams; bases
for columns, etc.; basement
slabs, under-reamed piles

and mass concrete


04054 Walls,
retaining walls,
basement walls, ballast
walls and the like;
any
thickness; above top of
footings; including attached
pilasters and buttresses
04055 Slabs supported on walls,
beams and columns in floors,
roofs, landings, balconies,
canopies, deck slabs and in

shelves and the like


04056 Chajjas

d Qa'kksZa dh laiwfrZ vkfn ds fy,] [kaM&13 ns[ksa& Q'kZ laiwfrZ rFkk


fcNkouA
[k csfYyr bLikr dh dM+h ;k /kju] bLikr LFkk.kqd esa fy- iVh
dahV dk Hkqxrku izofyr dahV :i esas gksxkA lajpuk bLikrh
fuekZ.k izFkd :i ls [k.M 10&bLikr rFkk yksgs ds dk;Z ds
varxZr ekik tk;xk rFkk bldk vk;ru] dahV ds vk;ru
ftlesa yxk gS] esa ls ugha ?kVk;k tk;sxkA fQj Hkh tgka isVh
LFkk.kqd vkfn dahV ls cus gSa rks isVh dk vk;ru ?kVk;k
tk;sxkA
x bLikr dk;Z dks cka/kus esa yxs rkj dks [k.M 9& fuekZ.k dh
/kkrq lkexzh ds vUrxZr izFkd ekik tk;xkA

lhesaV dahV

M-20
(20mm
graded
aggregates)

M-25
(20mm
graded
aggregates)

Rs.

Rs.

3315.20

3482.20

3799.50

3603.00
3964.20

3966.50

3770.00
4131.20

izfr ?ku ehVj


buesa izofyr lhesVa dahV ifjdYi feJ.k
M-30
dahV%&
(20mm
04053 uhoksa] jSVksa] iknksa] uhoa /kju] dqlhZ
graded
aggregates)
/kju] LrEHkksa ds vk/kkj vkfn lfgr
Rs.
rg[kkus ds iV~Vs] v/k os/ku LFkw.k

3649.20

4133.50

3935.00
4300.20

04054 nhokjks]a /kkjd nhokjks]a rg[kkus dh


nhokjkssa] fxV~Vh nhokjksa rFkk leku
fdlh eksVkbZ dh] iknksa ds 'kh"kZ ds
ij] rFkk lkFk yxs fHkfk LrEHk o
iq'krs lfgr
04055 nhokjksa ij vk/kkfjr ifV;ka /kju
o dM+h Q'kksZ] Nrksa] /kjkrykssa]
okydfu;ks]a Nkofj;ks]as ikVu ifV;ksa
rFkk 'kSYQ o leku essa
04056 NTtksa esa
04057 1-5 eh ls vf/kd ds vk;ru ds

/kju] izkl] ikVdM+h] fyaVy

04057 Beams,
cantilevers,
bressummers, lintels over

1.5m span

3837.10

4004.10

4171.20

04058 Columns,
pillars, piers,

posts and struts

3962.20

4159.00

4324.00

04058 LrEHkksa [kEHkks]a ik;ks]as [kwVa ks o Vsdksa esa

46

SECTION 4

SECTION 4 CONCRETE
[k.M 4& dahV
REINFORCED CEMENT CONCRETE WORK(DESIGN MIX)-Contd........

izofyr lhesaV dahV ds dk;Z ifjdYi feJ.k dahV& tkjh


fr ?ku ehVj

Cement Concrete

PER CUBIC METRE

lhesaV dahV

M-20
(20mm
graded
aggregates)

M-25
(20mm
graded
aggregates)

M-30
(20mm
graded
aggregates)

Rs.

Rs.

Rs.

3976.10

4143.10

4310.10

04060 Spiral staircases (including

landings)

5134.90

5311.20

5480.20

04061 Arches

3969.40

4136.50

4303.50

04061 esgjkosa

04062 Domes, vaults, shell roofs,


arch ribs and folded plates

4030.30

4197.30

4364.30

04063 Chimneys and shafts

3849.00

4022.00

4189.00

04064 Well steining and well curbs

3799.30

3966.40

4133.40

04065 Fins, fascias, louvres,


parapets, and railings exc.
60cm in height, newels,
balustrade, and the like

3976.10

4143.10

4310.10

65.50

65.50

65.50

Reinforced cement concrete (Design


mix):04059 Chullah hoods; stairways
(except spiral staircases)
including steps (square or
spandril), string pieces,
carriages, etc., complete, any
section straight or winding, but
excluding landings; RCC
water tanks upto 1500 litres

04066 Extra over item 04053, 04054


& 04058 for doing work in
water retaining structures

buesa ofyr lhesVa dahV ifjdYi feJ.k


dahV%&
04059 pqYgs N=d] lh<+h ds iFkksa ?kqekonkj
lh<+h ds vfrfjDr ikn lfgr oxhZ;
;k lfiZy yM+h Hkkx] dkBh vkfn
lai.w kZ] fdlh Hkh lh/kh ;k ?kqeko lfgr
vk/kkj ry] izofyr lheasV dahV
ds ikuh ds 1500 fyVj rd ds gkSt

04060 lfiZy lhf<;ksa lksiku lfgr

04062 xqEcn] pkis]a dkskh; Nr] ikqd


Z k MkV

o ca/kh ifV~Vdk;sa
04063 fpefu;ka o kSV
04064 dq;as dh txr o dq;as ds o ?kqeko
04065 fQu ik[ks eq[k iV~Vh] f>yfey
eqM
a js s o taxys vkfn 60 lseh ls vf/
kd WpkbZ ds] lksiku LrEHk] oY;kYkEc
taxyk rFkk leku

04066 ty /kkjd lajpukvksa esa dk;Z ds


fy, en 04053] 04054 o 04058 esa

tksM+as

CAST-IN-SITU BORED PILES

lhVw esa jfpr os/kd LFkw.k ikby


(a) The rate include for wastage allowance of 1.5m from
cut off level due to inter-mixing of clay slurry with
concrete. This length shall not be measured.
(b) Reinforcement shall be measured and paid under section 10.
(c) The payment be restricted to nominal bore of pile irrespective of actual bore of pile.
(d) The rate includes for temporary metal sheathing 1.5m
provided as guide.
(e) In case complete sheathing is used, the payment shall
be made separately for use of sheathing.

d njksas esa foPNsn Lrj ls 1-5 eh dk( daahV ds lkFk ckyw ds fey
tkus dk] Nhtu cV~Vk bu njksa esa kkfey gSA ;g yEckbZ ekih
ugha tk;sxhA
[k oyu dks ekik tk;sxk rFkk Hkqxrku [k.M 10 ds vUrxZr fd;k
tk;sxkA
x ctk; vk/kkj ds okLrfod cs/ku ds] Hkqxrku vk/kkj ds ukeh;
cs/ku rd gh lhfer j[kk tk;sxkA
?k njksa esa ekxZ nkZd :i esa 1-5 eh dk vLFkkbZ /kkrq vkoj.k kkfey
gSA
M+ ;fn iwjk vkoj.k iz;ksx fd;k tkrk gS rks vkoj.k iz;ksx dk
Hkqxrku izFkd ls fd;k tk;sxkA

47

SECTION 4

SECTION 4 CONCRETE
[k.M 4& dahV
CAST-IN-SITU BORED PILESContd..

lhVw esa jfpr cas/kd LFkw.k ikby&tkjh ..


iz R ;s d

DIA OF PILE

EACH

vk/kkj dk O;kl

04067 RCC (1:1:3) type Al as in


bored pile 16m length from

cut off level

450mm
Rs.
10769.60

500mm
Rs.
13374.50

530mm
Rs.
14889.50

04068 Add to item 04067 for each


additional 1 metre length

680.80

836.00

914.60

651.09

808.50

911.40

04069 Deduct from item 04067 for

each 1 metre length


MISC ITEMS
04070 Testing of pile in routine test
1.5 times the working load
as per I.S.I. specification
04071 Testing of pile in compression
as per I.S.I. specification upto
1.5 times vertical load (cyclic)
04072 Testing
of
pile
in
compression as per I.S.I.
specification upto 2.5 times
the working load (initial test)

04067 lekiu lrg ls 16 eh yEckbZ esa


csf/kr vk/kkj tSlh , 1 uewus dh vkj

lh lh 1%1%3
04068 R;sd 1 eh vfrfjDr yEckbZ ds

fy;s en 04067 esa tksM+sa


04069 R;sd 1 eh yEckbZ ds fy, en
04067 esa ls ?kVk;sa

fofo/k njsa
04070 vkbZ ,l vkbZ ds fofunsZ kksas ds vuqlkj
useh ijh{k.k] 1-5 ckj lgaf;rk ijh{k.k
04071 vkbZ ,l vkbZ ds fofuns'Z kksa ds vuqlkj
mnxz Hkkj vkorhZ ds 1-5 ckj laihMu
esa ijh{k.k djuk
04072 vkbZ ,l vkbZ ds fofunsZ kksas ds vuqlkj
dk;Zdkjh Hkkj izkjfEHkd ijh{k.k ds
2-5 ckj laihMu esa ijh{k.k djuk

PRECAST REINFORCED CEMENT CONCRETE


iwoZ fojfpr ofyr lhesaV dahV
POSTS, FENCING POSTS, DOOR AND WINDOW FRAMES
[kaHksa] ckM+ [kaHksa] njokts f[kM+fd;ksa dh pkS[kVsa
(a) These shall be of pre-cast reinforced cement concrete finished even and fair in frames/moulds.
(b) Supplied and Fixed rates include for forms/moulds
forming holes. Built-in articles such as pintle hooks,
blocks, etc. (measured separately).
(c) Supplied and Fixed rates and Fixing only rates
include for transporting and distributing the posts
etc. at required intervals, placing post in true position
and holding or staying same while ramming around
or concreting. Digging of post holes and concreting of
posts holes, if any, shall be measured separately.
(d) All holes shall be formed while casting.
(e) For rates of fixing and taking down wire fencing and
accessories, see Section 10, Steel and Iron work.
(f) Precast articles may be cast on waterproof platforms
provided the surface cast on the platform is even and
fair.

d ;g ofyr lhesaV dahV ds lkapksa@[kkapksa esa le o pedhyh


ifjd`rh ds lkaps@[kkapksa **iwoZ fofjpr** gksaxsA
[k **vkiwfrZ o LFkfir** dh njksa esa Nsn cukus o fuekZ.k dh oLrq,sa
tSls dhy dkaVs] ca/kd vkfn izFkd ekis tk;saxs kkfey gSaA
x **vkiwfrZ o LFkkiu** dh njksa o **LFkkiu dsoy** dh njksa esa [kEHkksa
vkfn dh <qykbZ o visf{kr vUrjky ij forfjr djuk lgh
fLFkfr esa j[kuk pkjksa vksj dh dqVkbZ djuk ;k dahV HkjkbZ
djuk kkfey gSA [kaHks ds xM~<s [kksnuk ;k xM~<ksa esa dahV Hkjus
dk dk;Z ;fn dksbZ gks rks og izFkd ekik tk;sxkA
?k <ykbZ ds nkSjku gh lHkh Nsn cuk;s tk;saxsA
M+ rkj dh ckM+ ;k lgk;d oLrqvksa dks yxkus ;k fudkyus dh njksa
ds fy;s [kaM 10& bLikr o yksgs ds dk;Z ns[ksaA
p iwoZ fojfpr oLrq,a] ty jks/kd pcqrjksa ij <kyh tk;sxh ckrZs
<ykbZ ds pcqrjs dh lrg lery o LoPN gksA

48

SECTION 4

SECTION 4-CONCRETE
[k.M 4& dahV
PRECAST REINFORCED CEMENT CONCRETEContd...
iwoZ fojfpr ofyr lhesaV dahV& tkjh
PER CUBIC METRE
04073 Providing reinforced cement
concrete type B-l, 1:2:4 (20 mm
graded aggregate) in precast
posts, fencing posts, straining
or terminal posts, struts etc. for
fencing, average sectional area
n exc 100 sq. cm, with or
without chamfered angles and
flat, splayed, rounded or mitred
tops as directed and fixed

M&L

Fixing only

lkexzh ,ao Je

dsoy LFkkiu

Rs.

Rs.

4999.50

855.20

04074 Ditto, but exc 100 and n exc 250

sq. cm

4853.20

730.20

04075 Ditto, but exc 250 and n exc 400

sq. cm

4704.80

610.00

04076 Precast reinforced cement


concrete type B0, 1:2:4 (12.5 mm
graded aggregate) in door and
windows frames, any size, single
or double rebated, including arrangement for fixing of hinges

and fixtures as required

6560.10

1335.90

izfr ?ku ehVj


04073 ckM Qsl
a yxkus ds fy;s iwoZ fojfpr [kaHkks]a
ckM+ [kaHkksa khkZ eqMas [kHks]a uksdnkj [kHkksas vkfn
esa ch&1 uewus dh 1%2%4 20feeh dh oxhZdr`
feykos dh izofyr lhesVa dhV dks vkSlru
100 oxZ lseh ls vuf/kd i[knkj ;k i[k
jfgr LFkkuksa esa Hkjuk rFkk vknskkuqlkj ijh
lrg dks likV] <yoka xksy ;k dyeh

cukdj [kHks dks fLFkj djuk


04074 mi;qDZ r] fdUrq 100 ls vf/kd rFkk 250
oxZ lseh ls vf/kd ugha

04075 mi;qDZ r] fdUrq 250 ls vf/kd rFkk 400

oxZ lseh ls vf/kd ugha


04076 iwoZ fojfpr] izofyr lheaVs dahV uewuk
chvks 1%2%4 12-5 feeh oxhZdr` feykok
dh dCts o visf{kr midj.k yxkus
ds izcU/k lfgr fdlh Hkh vkdkj o ,d
;k nks iSrkHk ds njokts o f[kM+fd;ksa dh

pkS[kVs

MISCELLANEOUS ITEMS
fofo/k ensa
PER SQUARE METRE
04077 Grouting 25 mm thick under stanchion bases or
grillages, etc. including any temporary
shuttering to edges with cement mortar 1:2
04078 Add to or deduct from item 04077 for each 5

mm thickness

Rs.

izfr oxZ ehVj

531.00

04077 lh[kpksa o fxfjyksa ds uhps vLFkkbZ iqrkoUnh lfgr]

1%2 lhesaV elkys dh 25 feeh eksVh HkjkbZ djuk


04078 izR;sd 5 feeh eksVkbZ ds fy, en 04077 esa tksM+sa ;k

mlesa ls ?kVk;sa

96.90

PER RUNNING METRE (INNER GIRTH


ONLY MEASURED)

izfr ehVj dsoy Hkhrjh ?ksjk fy;k tk;sxk

04079 Extra for forming fair finished drain or


channel 30 cm inner girth in cement
concrete, using ex- tra cement, including
forms, moulds, mi- tred/stopped ends

etc.
04080 Add or deduct for each 25 mm girth or part

thereof over or under 30cm ditto

04079 vfrfjDr 30 lseh Hkhrjh eksVkbZ dh lhesaV dahV


dh ukfy;ksa] ufydkvksa dks vfrfjDr lhesaV dk
iz;ksx djds] Qeksa] lkapksa] ladjs@can fdukjksa vkfn
lfgr ifjd`r laiwfrZ djus ds fy;s

04080 tksMas+ ;k ?kVk;sa 30 lseh ls vf/kd ;k de ifjeki ds


fy;s izfr 25 feeh ;k mlds Hkkx ds fy;s

14.90
1.90

49

SECTION 4

SECTION 4-CONCRETE
[k.M 4 dahV
MISCELLANEOUS ITEMSContd.......
fofo/k ensa& tkjh
Items 04081 to 04083 shall not be measured and paid for
in addition to Item for precast cement concrete or precast
reinforced cement concrete.

EACH

en 04081 ls 04083 ekih ugha tk;sx


a h rFkk iwoZ fojfpr ;k iwofZ ojfpr
izofyr lhesaV dahV dh enksa esa vfrfjDr ns; gksxkA

iz R ;s d

Rs.

04081 Forming mortice holes, n exc. 50 cu cm for


balusters, newels, rag-bolts, etc. and
grouting with cement mortar 1:2 after

balusters, etc. are fixed


04082 Ditto, exc 50 but n exc 100 cu cm

13.20
26.30

EACH (PER CENTIMETRE DEPTH)


04083 Forming dovetailed cavities, n exc 10cm x
10cm at top and 20cm x 20cm at bottom in
concrete cast-in-situ (plain or reinforced)
for holding down bolts, etc. for machinery,
stanchions, etc. including temporary forms
or moulds and carefully grouting round
bolts (after fixing) with cement concrete type
Bl, 1:2:4 (20mm graded aggregate) or

cement mortar 1:3, as directed

5.80

04081 taxyks]a lksikuks]a nkarns kj dkoyksa vkfn ds fy,] 50 ?ku


lseh ls vuf/kd ds Hkhrjh Nsn cukus rFkk taxys vkfn

dks yxkus ds ckn 1%2 ds lhesVa elkys dh HkjkbZ djuk


04082 mi;qDZ r] 50 ls vf/kd fdUrq 100 ?ku lseh ls vf/kd

ugha
izR;sd izfr lseh xgjkbZ
04083 LFkki dkoyksa vkfn dh Mopwy cukus ds fy;s] e'khuh
LFkw.kksa vkfn ds 'kh"kZ ij 10 X 10 lseh vuf/kd o ry
ij 20 X 20 lseh- LoLFkku ij fufeZr dahV lknk
;k izofyr esy[kkrh dksVjksa dh cukoV es]a vLFkk;h
Qeks ;k [kkapksa lfgr] rFkk ch 1 uewus dh 1%2%4 20
feeh oxZ feykos ;k lhesaV elkys 1%3 tSlk Hkh
funs'k gks ds vuqlkj esy[kkrh dksVj cukuk

CUTTING INTO OR THROUGH CONCRETE


dahV esa ;k vkjikj dVkbZ djuk
(a) The following rates are for cutting openings exceeding 0.1 sq. m superficial area in walls. Cutting through
walls for opening not exceeding 0.1 sq. m superficial
area shall be measured separately under Section
5Brick Work.
(b) The rates include for providing, fixing and removing
shoring or other temporary supports.
(c) The measurements for cutting through or sinking into
concrete shall be those of the net finished dimensions
of the opening or cutting ordered (less the measurements of the existing opening or cutting, if any). If a
wall is plastered or rendered, the net thickness of wall
excluding any plastering or rendering shall be measured.
(d) The rendering to sides, cill and soffits of new openings, etc. shall be measured separately under Section
14 Plastering and Pointing.
(e) Cutting through walls of precast concrete blocks shall
be paid as for cutting through stone walls.

d fuEu njsa nhokjksa ds ijh Hkkxksa esa 0-1 oeh- ls vf/kd ds }kj
dkVus ds fy;s gSaA nhokjksa esa 0-1 eh ls de dh }kj dVkbZ dks
vyx ls [k.M 5& bZVa dk;Z ds vUrxZr ekik tk;sxkA
[k bu njksa essa O;oLFkk djuk] LFkkiu o Vsd canh ;k vU; lgkjksa
dks gVkuk 'kkfey gSSaA
x dahV esa vkjikj dVkbZ ;k dahV esa fu{ks; dh eki og gksxh
tks vkns'kkuqlkj laiwfjr eks[kksa ;k dkaVksa dk fo'kq vk;ru gksxk
fo?keku eks[kksa ;k dkaV]s ;fn dksbZ gks rks de djds ;fn nhokj
ij iyLrj ;k vLrj.k fd;k x;k gS rks iyLrj ;k vLrj.k
dks NksM+dj fo'kq) eki yh tk;sxhA
?k u;s eks[kksa vkfn dh cxyksa] nsgyh o uhps ds ry vkfn [kaM 14
IkyLrj o Vhi dk;Z ds vUrxZr izFkd ekis tk;saxsA
M+ iwoZ fojfpr dahV pksdksa dh nhokj dh vkjikj dVkbZ dk] iRFkj
dh nhokj dVkbZ ds leku Hkqxrku gksxkA

50

SECTION 4

SECTION 4-CONCRETE
[k.M 4 dahV
CUTTING INTO OR THROUGH CONCRETEContd.....
dahV esa ;k vkjikj dVkbZ djuk& tkjh
PER CUBIC METRE
04084 Cutting opening in cement
concrete walls (any descript-ion)
for door, window and other
openings (with or without reveals)
or enlarging existing openings,
including trimming surfaces to

receive rendering, etc.

With or with Where reinforceout reinforce- ment is cut


ment
through

izfr ?ku ehVj

PER SQUARE METRE

04084 lhesV dahV dh nhokjksa fdlh izdkj dh


njokts]a f[kM+fd;ksa ;k vU; eks[kksa ds fy;s
ik[ks lfgr ;k jfgr ;k fo?keku LFkku dks
c<+kus ds fy,] lrg dh dkV NakV dj
vLrj.k djus ;ksX; cukus lfgr eks[ks

dkVuk
izfr oxZ ehVj

04085 Cutting upto a depth of 2.5cm


into concrete walls and
trimming surface as required,

girth exc. 30cm

04085 dahV dh nhokjksa esa 2-5 lseh dh


xgjkbZ rd dVkbZ djuk o 30 lsehls vf/kd ?ksjs esa drjuk

04086 Add for every 2.5cm extra or


part thereof in depth (upto

30cm depth)

izoyu lfgr
;k jfgr

tgka izoyu vkjikj


dkVh xbZ

Rs.

Rs.

1099.80

1693.80

109.70

200.50

04086 tksMas + 2-5 lseh ls mij ;k mlds Hkkx dh


xgjkbZ gsrq 30 lseh xgjkbZ rd
84.10

148.40

96.80

iz f r ehVj
04087 ufydk;s]a [kkpksas ;k irkeksa dh 15 lseh ls

vuf/kd ifjeki dh dVkbZ o lrgh drju

165.90

04088 mi;qZDr 15 lseh ls vf/kd fdUrq 30

lseh ls vuf/kd ifjeki

PER RUNNING METRE


04087 Cutting channels, grooves or
rebates n exc 15cm girth, and

trimming surface
04088 Ditto, exc 15 cm but n exc 30cm

girth

35.30

63.10

Superficial Area
PER CENTIMETRE OF
DEPTH (OF CUTTING)

04089 Cutting holes into


or through cement
concrete slabs,
chajjas,
etc.
reinforced
or

otherwise
04090 Add to item 04089
above if reinforcement
is
cut

through

mijh HkkXk

N exc 100 Exc 100sq


sq cm
cm but n exc
100 oxZ
250 sq cm

Exc 250sq
Exc 500sq
cm but n exc cm but n exc
500 sq cm
0.1 sqm

lseh
vuf/kd

250 oxZ lsehls vf/kd


ysfdu 500 oxZ
lseh vuf/kd

100 oxZ lsehls vf/kd


ysfdu 250 oxZ
lseh vuf/kd

500 oxZ lsehls vf/kd


ysfdu 0-1 oxZ
lseh vuf/kd

Rs.

Rs.

Rs.

Rs.

5.70

7.00

8.60

10.60

3.70

4.70

5.50

7.00

xgjkbZ dk izfr lseh


dkVus ds fy,s

04089 lhesaV dahV dh ifV;ksa


NTtksa vkfn izofyr ;k
vU;Fkk esa] vkjikj Nsn
dkVuk

04090 en 04089 esa tksM+s ;fn


izoyu vkjikj fd;k x;k
gS

51

SECTION 4

SECTION 4-CONCRETE
[k.M 4& dahV
TOOTHING AND BONDING
nkrk rFkk ca/ku
(IN REPAIRS AND ALTERATIONS)
ejEerksa rFkk ifjorZuksa esa
d nhokj vkfn esa nkrsa vkfn ds dVkbZ dk;Z esa] tgak lhessaV dahV
[kaM dh nhokj fpukbZ essa nkars cukdj mls fdlh Hkh izdkj ds
nX/k bZaV dh fpukbZ ;k iRFkj fpukbZ dk;Z ls] l;qDr djus ds
dk;Z dks en 04091 ds vUrxZr ekik tk;sxk u fd [kaM 5& bZVa
fpukbZ ;k [kaM 6&iRFkj fpukbZ dh leku enksa esaA
[k nakrksa o ca/ku dk;Z dks dsoy ubZ nhokj ds laidZ esa lh/kk ekik
tk;sxkA

(a) Cutting and forming toothing to walls, etc. where


cement concrete block walling is toothed and bonded
into walls of burnt brickwork or stonework of any
description, shall be measured under item 04091 and
not under similar items in Section 5Brickwork or
Section 6Stone Masonry.
(b) Toothing and bonding shall be measured on vertical
face in contact with new wall only.
PER SQUARE METRE

04091 Cutting
out
concrete blocks,
slabs, brickwork
or stone masonry
(in alter nate
course), forming
tooth-ings for
and
bonding
new work in
mortar into old
work, including
new materials
entering old wall

Set in cement mortar Set in cement mortar Except


1:4
1:6
blocks or
slabs set
lhesaV elkys esa 1%4
lhesaV elkys esa 1%6
in cement
mortar
Precast cement concrete
1:4
iwoZ fopfjr lhesaV dahV
Type B1
1:2:4
(20mm
graded
aggregate)

Type C1
1:3:6
(20mm
graded
aggregate)

uewuk ch1 uewuk lh1


1%2%4
1%3%6
20 feeh 20 feeh
dqy feJ.k dqy feJ.k

Type B1
1:2:4
(20mm
graded
aggregate)

Type C1
1:3:6
(20mm
graded
aggregate)

uewuk ch1 uewuk lh1


1%2%4
1%3%6
20 feeh 20 feeh
dqy feJ.k dqy feJ.k

pksd]s
ifV;k
jfgr
lhesVa
elkyk
1%4

Except
blocks or
slabs set
in cement
mortar
1:6

pksd]s
ifV;k
jfgr
lhesVa
elkyk
1%6

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

674.40

655.20

615.40

595.60

471.30

411.00

izfr oxZ ehVj

04091 dahV [kaMks]a ifV;ks]a


bZaV dh fpukbZ ;k
iRFkj dh fpukbZ esa
dVkbZ djds
,dkUrj jn~nk
nkars cukuk rFkk
iqjkuh nhokj esas
yxus okyh ubZ
lkexzh lfgr] u;s
dk;Z iqjkus dk;Z ls
elkys] dh ls

la;Dq r djuk

POLYESTER TRIANGULAR FIBRES AS SECONDARY


REINFORCEMENT IN CONCRETES AND MORTARS
(a) Polyester triangular fibres shall be 6/12mm long with circum circle diameter of 30-35 microns, designed for
melting point of 240-260 degree Celsius & having specific gravity 1.34-1.40. These shall be approved makes.
(b) Polyester triangular fibres, where indicated, shall be uniformally mixed at the rate of 0.25% (or at the rate as per
manufacturer's instructions) by weight of cement (in case of Cement Concrete/mortar), lime (in case of lime
concrete/mortar) and "Cement + lime" (in case of cement lime concrete / mortar). Quantity of polyester triangular
fibres shall be worked out and paid as "Supply only" under following item No 04092. Mixing shall be deemed to
be included in respective main item (like integral water proofing compound).
PER KILOGRAM
04092 Supply only polyester triangular fibres as
secondary reinforcement in all types of

concrete and mortars

Rs.
323.10

52

SECTION 4

SECTION 4-CONCRETE
[k.M 4& dahV
MATERIALS (Supplied only)
lkexzh dsoy vkiwfrZ
feykos dks lery Hkwfe ij yxk;s x;s l?ku pV`Vksa esa fo'kq ekik
tk;sxkA tgka funsZ'k gks lkexzh dks QeksZ ryh jfgr izekih cDls esa
ekik tk;sxkA tcfd] fo'ks"k l?kurk ds fy, vko';d ugha gS fd
lkexzh dsk dwVk tk;s] >d>ksjk tk; ;k ?kuksa ls dqVkbZ dh tk;] fQj
Hkh <hys pV~Vs yxkus ds fdlh Hkh iz;kl dh Lohd`fr ugha gksxhA

Aggregate shall be measured net, in compact stacks,


prepared on level ground. Where directed, the materials
shall be measured in 'pharmas' (bottomless gauge boxes).
While no special compaction is necessary by ramming,
jerking or hammering. No attempt at loose staking shall
be permitted.

Nominal size ukeh;

PER CUBIC METRE

izfr ?ku ehVj

eki

63mm

40mm

20mm

12.5mm

coarse

Rs.
587.50

Rs.
587.50

Rs.
646.30

Rs.
675.00

04094 Broken brick coarse

aggregate

499.40

528.80

528.80

528.80

04093 Graded
aggregate

PER CUBIC METRE

646.30

04096 Surkhi (Burnt clay pozzolana)

411.30

PER 50 KG

04097 Lime, unslaked

04095 dahV ds fy;s eghu Ckkyw feykok


04096 lq[khZ HkLeh jk[k ikstksykuk

Fat or magnesium

Semihydraulic
or kankar

Eminently
hydraulic

'kq ;k eSxus]
f'k;e

v/kZtyh; ;k
dadj

iw.kZ tyh;

Rs.
223.25

Rs.
204.90

Rs.
215.30

PER 50 KG BAG
04098 Cement ordinary portland, portland

pozzolana or portland slag

04097 pwuk] vucq>k


izfr 50 fdyksxzke cksjh

270.30

04098 lhesaV lkekU; iksVZySaM] iksVZySaM ikstks ;k iksVZySaM


LySx
izfr fdyksxzke

35.30

PER LITRE
04100 Liquid water proofing compound

izfr 50 fdyksxzke

Rs.

PER KILOGRAM
04099 Integral waterproofing compound

04094 bZaV jksM+h dk LFkwy feykok

izfr ?ku ehVj

Rs.

04095 Fine aggregate (sand) for concrete

04093 LFkwy dksfV dk feykok

04099 lkefjd tyjks/kd ?kksy


iz f r fyVj

193.90

04100 rjy tyjks/kd ?kksy

53

SECTION 4

Fig. 4.1.1

Fig. 4.1.2

54

SECTION 5

SECTION 5 BRICK WORK


[k.M 5 bZV dk dk;Z
SPECIAL CONDITIONS
foksk 'krsZ
5.1
Measurements
5-1 eki
5.1.1 Thickness of wallingBrick walls upto and
5-1-1 nhokj fpukbZ dh eksVkbZ vk/kh ;k de bZV dh eksVkbZ okyh
including three bricks in thickness, excepting walls
nhokjsa o Nkk nhokjksa dks NksMd
+ j rhu bZV dh rhu j}k nhokjksa
half brick thick and less and honey-comb walls,
dh eksVkbZ dh eki vk/kh bZV ds xq.kd esa ekih tk;sxh ftlesa
shall be measured in multiples of half brick which
shall be deemed to be inclusive of the mortar joints.
elkys ls Hkjs tksM+ksa dks 'kkfey le>k tk;sxkA
5.1.1.1 Where fractions of half brick occur due to archi- 5-1-1-1 tgka okLrq f'kYi ;k vU; dkj.kksa ls vk/kh bZV ds VqdM+sa vkrs
tectural or other reasons, the measurement shall
gSa mudh eki fuEu izdkj ls gksxh%&
be taken as follows: d bZV rd
okLrfod eki
(a) Upto brick
Actual measurement
[k bZV ls vf/kd
vk/kh bZV
(b) Exceeding brick
Half-brick
5.1.1.2 The following shall be taken as half brick 5-1-1-2 fuEu dks vk/kh bZV dh eki ekuk tk;sxk%&
measurement :vafdr bZV dh ukHkh; pkSMkbZ tSlh n'kkZ;h xbZ gSA
The nominal width of the brick as indicated.
5.1.1.3 For walling which is more than three bricks in
thickness, the actual thickness of wall shall be
measured to the nearest one centimetre.
5.1.1.4 Walls half brick thick and less and honey-comb
walls shall be measured in square metres.
5.1.2

DeductionsNo deductions or additions shall be


made on any account for :
(1) Ends of dissimilar materials (i.e., joists, beams,
lintels, posts, girders, rafters, purlins, trusses,
corbels, steps, etc.) upto 0.1 sq. m in section.

Note:-

(2) Opening upto 0.1 sq. m in area.


In calculating this area, the size of opening
shall include any separate lintels or cills but
not the extra width of rebated reveals, if any,
and end portion of the lintels.
(3) Wall and bed plates, bearing of slabs, chajjas
and the like where the thickness does not exceed
10cm and the bearing does not extend over the
full thickness of the wall.
(4) Cement concrete blocks as for hold fasts and
holding down bolts.
(5) Iron fixtures such as Wall ties, pipes upto 300
dia and hold fasts for doors and windows, etc.

5-1-1-3 rhu bZVksa ls vf/kd eksVh nhokjksa dh eksVkbZ dks fudVre


,d lseh rd ekik tk;sxkA
5-1-1-4 vk/kh bZV o de dh nhokjksa rFkk Nkk nhokjksa dh oxZ ehVj
esa ekik tk;sxkA
5-1-2 dVkSfr;k% bu ij u dksbZ dVkSrh gksxh vkSj u gh vfrfjDr
fn;k tk;sxk%&
1 vleku oLrqvksa ds Nksjksa tSls dfM;ka] /kju] fyaVy]
[kaHks] xkMj] cks] 'kgrhj] dSfa p;ka] VksM]s lhf<+;ka vkfn dks
0-1 oxZ eh- rd [kaM esa
2 0-1 oxZ eh rd {ks= ds [kqys LFkku
uksV% bl {ks= dks ekius ds fy;s fdlh i`Fkd fyaVy ;k
fly dks 'kkfey fd;k tk;sxk fdUrq iSrke ds ik[ks
;fn gks o fyaVy dk Nksj dk Hkkx 'kkfey ugha gksxkA

4
5

idM+ ifk;ksa o LFkkid esa Mkyh xbZ lhesaV dahV

yksgs ds lkt tSls [kawfV;ka] 300 feeh O;kl rd ds uy


rFkk f[kM+dh njoktksa dh idM+ ifk;ka
(6) Chases of section, not exceeding 50 cm in girth. 6
50 lseh vuf/kd ?ksj ds dVko Nsn
(7) Volume occupied by joists except in case of box 7
dM+h dk vk;ru flok; lfj;ksa ds cDls ;k isVh xkMj ,sls
stanchions or girders in which case boxed
ekeyksa esa dsoy HkjkbZ ?kVkbZ tk;sxhA
portion only shall be deducted.
Ygs] fpeuh vkfn% flok; nx/k bZV dk;Z fpeuh dh
5.1.3 Fireplaces, Chimneys, etc. Brickwork (excluding 5-1-3 p qYgs
fire brickwork) in chimney breasts and chimney
eksgjh o fpeuh iqat esa] /kqa;s ;k gok 0-2 oxZ eh dkV {ks=
stacks with smoke or air flues not exc. 0.2 sq. m
ds
Nsn ds lkFk] bZV fpukbZ dks Bksl ekik tk;sxk rFkk ,sls
sectional area) shall be measured as solid and no
extra payment shall be made for pargeting and
Nsnksa dh fyikbZ iqrkbZ dk vfrfjDr Hkqxrku ugha gksxk tgka
coring such flues; where the flues exceed 0.2 sq.m
dkV {ks= 0-2 oxZ eh ls vf/kd gS mldh dVkSrh bZV dk;Z
in sectional area, deduction for the same shall be
esa ls gksxh rFkk fyikbZ iqrkbZ [kaM 14 iyLrj dk;Z rFkk
made from brickwork and pargeting and coring
measured extra under Section 14Plastering and
Vhi dk;Z ds vUrxZr ekih tk;sxhA pwYgs ds }kjd Nsn
Pointing. Apertures for fireplaces shall not be
ugha ?kVsaxs rFkk fpeuh ds ik[kksa daBksa dks <yoka djus ds
deducted and extra labour shall not be measured
vfrfjDr Je] dks ughas ekik tk;sxkA
for splaying of jambs and throating.

55

SECTION 5

SECTION 5 BRICK WORK


[k.M 5 bZV dk dk;Z
SPECIAL CONDITIONSContd...
foksk 'krsZ tkjh
5.1.4 Pillars Circular or polygonal pillars shall be 5-1-4 LrEHk xksy ;k cgqHkqth LrEHkksa dks fo'kq) ekik tk;sxkA
measured net.
Note- Rectangular pillar/column shall mean a detached
masonry portion such that its breadth does not
exceed three times its thickness and thickness itself
does not exceed three brick length.
5.1.5 Battered, tapered or curved walls shall be measured net.
5.1.6 Honey-comb brick work shall be measured as solid,
the voids not being deducted.
5.1.7 Brick noggingNo deduction shall be made in respect
of timber (studs and nogging pieces etc.) framing.
5.2 Rates
5.2.1 The rates for new brickwork generally include for:
(a) Bricks of sizes as indicated.
(b) All scaffolding, ladders, plant and templates
required.
(c) Extra labour in eaves or beam filling.
(d) Rough cutting and waste for forming gables,
cores of arches, splays at eaves and the like
and all rough cutting and waste in the body of
brickwork, unless otherwise stated.
(e) Raking out joints for plaster or for pointing
where specified or finishing the joints flush as
the work proceeds.
(f) Levelling up and preparing tops of walls for
damp proof courses, floor and roof slabs, etc.
levelling riveted tops of girders, etc.. Bearing
plaster and white washing etc. shall be
measured separately.
(g) Bedding wall plates, lintels, cills, roof tiles and
corrugated sheet etc., in or on walls solidly in
mortar as for adjacent work and making good.
(h) Building in or cutting and pinning in mortar
as for adjacent work, ends of joists, beams,
lintels, slabs, cills, trusses etc. and making good.
(j) Making or leaving holes for fixing pipes, bolts
etc. and weep-holes, and making good,
including grouting, if necessary.
(k) Leaving or forming chases (or cutting instead
at the option of the contractor where approved
by EIC) for ends or edges of slabs, landings,
shelves, sunshades, steps, cills and the like not
exc. 50 cm in girth.
(l) Forming or leaving chases (or cutting instead
at the option of the contractor where approved
by EIC) for concealed water tubing and
concealed conduit wiring.
(m) Building in holdfasts, air bricks, fixing bricks,
grates, soot doors, cast iron boxes etc. and
making good.
(n) Pargetting and coring (with cowdung and lime
mortar) flues upto 0.20 sq. m sectional area.
(o) Building the exposed faces fair.
(p) Selecting the best bricks for facing in exposed
brick-work.
(q) Plumbing to angles.

uks V % vk;rkdkj [kEHkksa dk vFkZ gS fpukbZ dk ,slk fufyZIr Hkkx


ftlesa bldh pkSMk+ bZ] eksVkbZ ds rhu xqus ls vf/kd u gks rFkk
Lo;a eksVkbZ rhu bZV dh yEckbZ ls vf/kd u gksA
5-1-5 <yok] 'kqUMkdkj ;k o nhokjsa fo'kq) ekih tk;saxhA
5-1-6 NRrk djaMh nhokj ds bZV dk;Z dks Bksl ekik tk;sxk] [kkyh
LFkkuks dh dVkSrh ugha gksxhA
5-1-7 bZV [kwaVh ydM+h dh r[rscanh es[k o [kwaVh dh dksbZ dVkSrh
ugha gksxhA
5-2 njsa
5-2-1 uohu bZV fpukbZ dk;Z dh njksa esa lkekU;r% ;g 'kkfey gksrk gS%&
d fufnZ"Vr vkdkj dh bZVsaA
[k lHkh visf{kr isM ca/kkbZ lkeku] lhf<+;ka] la;=a o lkaps vkfnA
x vksyrh ;k /kju che Hkjus ds fy;s vfrfjDr JfedA
?k Nr ds xksys xscy MkVksa ds fdukjs] vksyrh ds <yku rFkk
leku oLrqvksa dh cukbZ esa eksVh dVkbZ o Nhtu rFkk bZV dk;Z
es]a tc rd vU;Fkk u dgk x;k gks] eksVh dVkbZ o NhtuA
M+ tgka fufnZ"V gks iyLrj ;k Vhi djus ds fy, tksMk+ as dks
[kqjpuk ;k tSls tSls dk;Z vkxs c<+rk gS tksMk+ as dh likV
laiwfkZ djukA
p nhokjks]a Q'kksZ rFkk Nr dh dfM+;ksa ds ijh Hkkx vkfn esa
lhyu jks/kh jn~ns ds fy,] lery djuk rFkk rS;kj
djuk] xMZj vkfn dh ijh mHkjh lrg dks le djukA
iyLrj dh ijr o lQsnh vkfn dks izFkd ekik tk;sxkA
N nhokj iV~Vh] fyaVy] fly] Nr Vkbysa o iukjhnkj
pnnjksa vkfn dh nhokj esa ;k nhokj ij tSlk lkFk ds
dk;Z es gS muesa fdukjs cukuk ;k dkVuk rFkk elkys esa
tksM+uk o Bhd djukA
> uy] dkoys vkfn yxkus ds fy, Nsn cukuk ;k NksM+uk
rFkk Nsn NksM+rs gq,] ;fn vko';d gks] elkys HkjkbZ
lfgr Bhd djukA
= ifV;ks]a /kjuh] /kjuks]a 'kSyQks]a NTtksa lhf<+;ks]a flyksa rFkk
50 lseh vuf/kd ?ksjs dh vU; leku oLrqvksa ds Nksj ;k
fdukjksa ds fy, fjDr;ka NksMu+ k ;k cukuk ;k Bsdns kj ds
foosdkuqlkj tgka izHkkjh vfHk;ark dh Lohd`fr gks rks
blds ctk; dkV dj Nsn cukukA
V ncs gq;s ikuh ds uyksa o nch rkj ufydkvksa ds fy, Nsn
cukuk ;k fjfDr;ka NksMu+ k ;k ctk; blds Bsdns kj dh ethZ
o izHkkjh vfHk;ark dh Lohd`fr ls dkV dj Nsn cukukA
B /kkjd ifk] fNfbnz bZV] eksgjk bZV] tkyh dTty njokts
<ys yksgs ds cDls vkfn ds fy, LFkku cukuk o Bhd djukA
M 0-20 oxZ eh rd dkV {ks= ds Nsnksa dks iyLrj o fyikbZ djds Bhd cukuk xkscj o pwuk elkys lsA
< fn[kkbZ nsus okys Hkkx dks fpduk djukA
.k fn[kkbZ nsus okyh bZV fpukbZ ds fy;s vPNh bZVksa dk
pquko djukA
r dks.kksa dks lh/kk djukA

56

SECTION 5

SECTION 5- BRICK WORK


[k.M 5 bZV dk dk;Z
(r) Forming reveals to jambs where fair cutting on
Fk tgka fn[kkbZ nsus okys Hkkx essa lkQ dVkbZ ugha vkrh ogka
exposed faces is not involved.
iD[kksa ds ckgjh Hkkx cukukA
(s) Preparing tops and sides of existing walls and
n ij mBkus o c<+kus ds fy;s fo|eku nhokjksa ;k leku
the like for raising and extending.
dk;ksZ ds ijh Hkkxksa o cxyksa dks rS;kj djukA
(t) Forming openings and flues for which no
/k eks[ks o fpeuh eq[k cukuk ftlds fy;s dksbZ dVkSrh ugha gksxhA
deduction is to be made.

(u) Building in vertical seismic reinforcement at


the jambs of openings, corners of walls, etc.
including grouting in cement mortar 1:4.
(v) Keeping Brick work well wetted during the
curing period.
5.2.2 Rates for brickwork apply also to the following:
(a) Reinforced brickwork in walls when
reinforcement is laid parallel to the courses
and brickwork with seismic reinforcement
(reinforcement shall be measured separately
under Section 10Steel and Iron Work).
(b) Walls built either perpendicular, battered or
tapered including pillasters and brick on edge
courses, straight or curved on plan to a mean
radius exc 6m.
(c) Chimney breasts, chimney stacks (i.e., single flue
or groups of flues carried above a roof) except
independent chimney shafts as in factories, etc.
Fire brickwork will be measured separately.
(d) Bridges, culverts, etc.
(e) Brick nogging as in partitions, etc.
(f) Plain copings, cills, cornices, corbels,
oversailing courses, string courses, etc.
5.2.3 Exclusion The rates (except item 05085 & 05086)
do not include for provision of either sewer bricks or heavy
duty burnt clay building bricks or paving bricks.
5.2.4 Cavity Walls The skin forming part of cavity walls
shall be paid at the corresponding rates for brickwork
(viz., half brick thick, brick-on-edge, etc.) according to the
thickness of each skin.
5.2.5 Rates given in item 05034 to 05073 are applicable for
both burnt clay brick work and fly ash brick work.
5.2.6 Circular or polygonal pillars The rates of circular
or polygonal pillars shall be that of the appropriate items
of brickwork with the following multipliers:Discription of work

dk;Z dk fooj.k

Materials and Labour

lkexzh o Je

u eks[ks ds ik[kksa nhokjksa ds fdukjs vkfn ij lekukUrj


HkwdEih izoyu esas 1%4 elkys dh HkjkbZ lfgr lgfuekZ.kA
i lalk/ku dky esa bZV fpukbZ dk;Z dks xhyk j[kukA
5-2-2 bZV fpukbZ dk;Z dh njsa bu ij Hkh ykxw gksrh gS%&
d nhokjksa esa izofyr bZV fpukbZ tc izoyu fpukbZ jn~ns ds
lekukUrj Hkwdia h izoyu ds lkFk fcNkbZ xbZ gks izoyu
[kaM 10 bLikr rFkk yksgs ds dk;Z ds vUrxZr ekik tk;sxkA
[k nhokjsa pkgs yEcku] dks.knkj ;k nhokj LrEHk lfgr
'kqUMkdkj cuh gksa rFkk 6 eh- ls vf/kd ek/; f=T;k
;kstuk ls lh/kh ;k o vk[kjh jn~ns ij yxh bZVsaA
x fpeuh dh eksgjh] fpeuh Lda/k vFkkZr~ ,d iFk ;k lewg
iFk Nr ds ij ys tk;s x;s flok; dkj[kkus vkfn dh
rjg Lora= 'kSV fpeuh ds nX/k bZVksa dh fpukbZ izFkd
ekih tk;sxhA
?k iqy] iqfy;k vkfnA
M foHkktu vkfn dh rjg NTth nhokjsaA
p lknh eqMjs ]as flys]a dxkj] rk[ks] pyrs jn~n]s fdadjh jn~ns vkfnA
5-2-3 viotZu% bu njksa esa 05085 o 05086 ds vykok u rks
iz.kky bZVksa ;k Hkkjh dk;Z nX/k fpduh feh dh fuekZ.k bZV] ;k [kaMpk
bZVksa dk izko/kku gSA
5-2-4 dksVj nhokjsa% dksVj nhokjksa dk f>Yyh cukus okys Hkkx dk
Hkqxrku] bZV dk;Z dh vuq:i njksa esa tSls vk/kh bZV eksVh] [kM+h bZV
vkfn izR;sd f>Yyh ds fy;s gksxkA
5-2-5 en 05034 ls 05073 dh njsa fpduh feh ls cuh nX/k bZVksa dk dk;Z
vkSj e'khu ls x<+h gqbZ ykbZ ,s'k bZVksa dk dk;Z nksuks ds fy, ykxw gSA
5-2-6 xksy ;k cgqHkqth LrEHk% xksy ;k cgqHkqth LrEHkksa dh njsa bZV
dk;Z dh mi;qDr njksa dks fuEu xq.kd }kjk xq.kk djds cuk;k tk;sxk%&
Standard Schedule Rate Multiplied by

ekud vuqlwph dh njksa dks xq.kk djas


For circular pillars

For polygonal pillars

xksy LrEHk gsrq

Ckgqdks.kh; LrEHk gsrq

1.9

1.5

2.5

2.0

Except bricks

bZV jfgr

57

SECTION 5

SECTION 5- BRICK WORK


[k.M 5 bZV dk dk;Z
BRICKWORK IN BURNT BRICKS
nX/k bZVksa ls bZV fpukbZ
(a) Bricks unless otherwise described shall mean common
burnt clay building bricks.
(b) The rates for work curved or polygonal on plan include
for all extra cutting and extra waste in the body of the
work. It shall be measured as mean length of wall.
(c) Centering to arches, etc. shall be measured under
Section 7Woodwork (Carpenters work).
(d) Sinking of steining shall be measured separately vide
Items 03004 to 03008 of Section 3Earthwork. Well
curbs, tie-rods, etc. shall be measured under the appropriate
Sections.
(e) Rates given in SI item 05001 to 05015 are for bricks of
class designation 75 ( Kgf/cm2).
(J) For other class designation i.e. 125, 100, 50 extra as
per SI item 05032, 05033, shall be added to/deducted
from SI item 05004 & 05010.

PER CUBIC METRE

d bZVksa dks tc rd vU;Fkk o.kZu u gksa] lkekU; fpduh feh ls cuh


nX/k bekjrh bZVsa ekuk tk;sxkA
[k o ;k cgqHkqth vk;kstu dk;Z dh njksa esa lHkh vfrfjDr dVkbZ
o vfrfjDr Nhtu 'kkfey gSA ;g nhokj dh ek/; yEckbZ tSls
ekik tk;sxkA
x esgjkoksa MkV vkfn dh <wykcanh [kaM 7 ydM+h ds dk;Z c<+bZ dk
dke ds vUrxZr ekih tk;sxhA
?k dq,a dh xyh xksys dh nhokj dks izFkd ls [kaM 3 feh dk dk;Z
dh en 03004 ls 03008 esa ekik tk;sxkA dq,a ds ikV] ca/ku NM+sa
vkfn dks mi;qZDr [kaM ds vUrxZr ekik tk;sxkA
M- e en 05001 ls 05015 esa nh xbZ bZVksa dh njsa Js.kh laKk 75
75 fdxzk@lseh2 dh gSA
p vU; Js.kh laKk vFkkZr~ 125] 100] 50 buds fy;s vfrfjDr en
05032] 05033 dh njksa dks nj 05004 vkSj 05010 esa tksM+k ;k
?kVk;k tk;sxkA

Laid dry

In mud mortar

lw[kh fcNkbZ

xkjk elkyk

Old size Modular Except Old size Modular


bricks
bricks
bricks bricks
bricks
05001 Brickwork with
sub- class B
bricks straight or
curved on plan
exc 6 m mean

radius
05002 Ditto, in curved
work on plan
with mean radius

n. exc. 6 m
05003 Ditto, in circular
well steining
(any radius)
constructed from
the base or curb

Except
bricks

iqjkus eki ekikad bZV bZV jfgr iqjkus eki ekikad bZV bZV jfgr
dh bZV
dh bZV
Rs.

Rs.

1519.90

1718.60

1566.20

1764.90

Rs.

Rs.

Rs.

191.10 1461.90 1617.90

237.40 1561.10 1717.10

izfr ?ku ehVj

Rs.

431.10

530.40

05001 ^ch* miJs.kh dh bZVksa ls


lek;kstu ij 6 eh ls
vf/kd vkSlr f=T;k dh
lh/kh ;k o fpukbZ

05002 mi;qZDr] o dk;Z esa


lek;ks t u ij 6 eh ls
vuf/kd vkSlr f=T;k dh
05003 mi;qZDr] xksy dwi xksys
esa fdlh f=T;k ds]
vk/kkj ;k o ls fufeZr

1796.90

2001.40

437.90 1732.10 1888.10

701.30

58

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
BRICKWORK IN BURNT BRICKSContd...
nX/k bZVksa ls bZV fpukbZ tkjh
OLD SIZE BRICKS/TILES
PER CUBIC METRE

iq j kus uki dh bZ V s a @ Vkbys a


iz f r ?ku ehVj
Lime mortar
pwuk elkyk

05004 Brickwork with subclass


B bricks, straight or
curved on plan exc 6m
mean radius built in

1:4

1:3

Rs.

Rs.

1923.50 2009.20

Cement lime mortar


lhesaV pwuk elkyk

1:2

1:2:9

1:1:8

Rs.

Rs.

Rs.

2076.20

2113.70

2089.80

Add if subclass A
bricks or
brick tiles
are used
, miJs.kh
bZV ;k
Vkby ij

Cement mortar
lhesVa elkyk

1:1:6

1:8

1:6

Rs.

Rs.

Rs.

2191.80 2093.40 2180.50

1:4

1:3

Rs.

Rs.

2351.90 2448.60

Bricks
or brick
tiles
only
bZV ;k
Vkby
dsoy

tksM+s
Rs.

Rs.

71.90

1030.70

05004 ^ch* miJs.kh dh bZVksa ls lek;kstu


ij 6 eh ls vf/kd vkSlr f=T;k
dh lh/kh ;k o fpukbZ] var% fufeZr

PER SQUARE METRE

iz f r oxZ ehVj

05005 Brickwork with subclass B bricks, straight


or curved on plan to any
radius in half brick thick

walls built in
05006 Brickwork with sub-class
B bricks in brick-on-edge
walls (less than brick

thick), built in

05005 ^ch* miJs.kh dh bZVksa ls lek;kstu


ij fdlh Hkh f=T;k dh vk/kh bZV
dh eksVkbZ dh lh/kh ;k o nhokj
dh bZV fpukbZ dk;Z] varfufeZr

244.00

250.20

257.00

253.30

263.80

255.90 263.80

280.00

315.80

9.00

128.80

180.40

184.80

187.00

181.90

180.10

182.90

187.50 190.80

197.10

209.60

6.20

88.40

340.40

346.50

351.30

354.30

352.60

360.00

360.80 367.20

379.80

390.40

13.20

189.50

166.70

169.30

170.50

172.50

169.70

175.20

177.90 180.90

186.60

195.90

6.50

93.50

131.30

132.60

133.70

134.70

134.10

135.50

140.20 142.20

145.00

151.70

4.40

63.20

0 5 0 0 6 ^^ch** miJs.kh dh bZVksa ;k bZV


Vkbyksa ls [kMh+ bZV dh nhokj esa
bZV ls de eksVkbZ bZV fpukbZ

dk;Z] varfufeZr
0 5 0 0 7 ^^ch** miJs.kh dh bZVksa ls ,d
bZV eksVkbZ dh djaMh Nrk
nhokjksa esa bZV fpukbZ dk;Z]

var%fufeZr
0 5 0 0 8 mi;qDZ r] vk/kh bZV eksVkbZ dh
djaMh nhokjksa esa] varfufeZr

0 5 0 0 9 mi;qZDr] [kM+h bZV dh djaMh


nhokjksa esa vk/kh bZV ls de
eksVh var%fufeZr

SECTION 5

05007 Brickwork with sub class


B bricks in one brick
thick honey comb

walling, built in
05008 Ditto in half-brick thick
honey-comb walling, built

in
05009 Ditto in brick-on-edge
honey comb walling (less
than half brick thick),

built in

237.10

SECTION 5

SECTION 5- BRICK WORK


[k.M 5 bZV dk dk;Z
BRICKWORK IN BURNT BRICKSContd...
nX/k bZVksa ls fpukbZ tkjh
Add if
subclass A
bricks
or brick
tiles are
used

MODULAR BRICKS/TILES

PER CUBIC METRE

05010 Brick work with subclass B bricks,


straight or curved on
plan exc 6m mean
radius, built in

Lime mortar

Cement lime mortar

Cement mortar

pwuk elkyk

lhesaV pwuk elkyk

lhesaV elkyk

ekMw y j bZ V s a @ Vkbys a
izfr ?ku ehVj

bZV ;k
, miJs.kh Vkby
bZV ;k
dsoy
Vkby ij
tksMs+
1:4

1:3

1:2

Rs.

Rs.

Rs.

2063.60 2144.40 2200.10

1:2:9

1:1:8

1:1:6

Rs.

Rs.

Rs.

2270.80 2235.00 2320.00

1:8

1:6

1:4

1:3

Rs.

Rs.

Rs.

Rs.

2244.70 2331.90 2503.70 2651.80

Rs.
89.00

PER SQUARE METRE


05011 Brickwork with subclass B bricks, straight
or curved on plan to any
radius in half brick thick

walls, built in

Bricks
or
brick
tiles
only

05010 ^ch* Js.kh dh bZVksa ls


lek;kstu ij 6 eh ls
vf/kd vkSlr f=T;k dh
Rs.
lh/kh ;k o nhokj bZV
1186.70
fpukbZ dk;Z] var%fufeZr
izfr oxZ ehVj

225.40

233.10

239.10

249.40

250.00

251.30

246.50

254.70

270.90

289.00

9.00

119.80

05012 Brickwork with subclass B brick tiles


in half brick thick
walls, built in

226.60

231.50

235.20

228.90

226.70

272.30

232.50

237.20

246.90

285.70

9.00

119.80

328.00

330.80

335.30

339.70

327.40

343.20

345.40

349.90

361.70

370.10

13.60

180.90

05015 Ditto, in half brick

thick, Ditto

153.70

154.90

156.90

158.60

157.70

160.20

165.20

167.60

170.50

174.90

6.20

82.20

59

05013 Brickwork with subclass B brick tiles in


brick-on-edge wall
(less than brick
thick), built in
05014 Brickwork, with subclass B bricks in one
brick thick honey comb
work, built in

05011 ^ch* Js.kh dh bZVksa ls


lek;kstu ij fdlh Hkh
f=T;k dh vk/kh bZV
eksVh nhokj esa bZV fpukbZ
dk;Z] varfufeZr
05012 ^ch* Js.kh dh bZV Vkby
dh vk/kh bZV eksVh nhokjksa
esa bZV fpukbZ dk;Z]
varfufeZr
05013 ^ch* miJs.kh dh bZV
Vkby dhs [kMh+ bZV
nhokj bZV ls de
eksVh esa bZV fpukbZ
dk;Z] varfufeZr
05014 ^ch* miJs.kh dh bZVks
lsa djaMh nhokjksa esa ,d
bZV eksVh bZV fpukbZ
dk;Z] var%fufeZr
05015 mi;q Z D r] vk/kh bZ V
eksVh] mi;qZDr

60

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z bZV
BRICKWORK IN BURNT CLAY FLY ASH BRICKS
nX/k] mMu jk[k bZVksa ls bZV fpukbZ

SECTION 5

(a) Fly ash bricks shall be burnt clay flyash building d mMu jk[k bZVs Hkk ek&13757 ds vuqlkj Hkou fuekZ.k ds fy,
bricks as per IS- 13757.
fpduh feh vkSj mMu jk[k ls cuh gksaxhA
(b) The rates for work curved or polygonal on plan include
[k o ;k cgqHkqth vk;kstu dk;Z dh njksa esa lHkh vfrfjDr dVkbZ
for all extra cutting and extra waste in the body of the
o vfrfjDr Nhtu 'kkfey gSA ;g nhokj dh ek/; yEckbZ tSls
work. It shall be measured as mean length of wall.
ekik tk;sxkA
x esgjkoksa MkV vkfn dh <wykcanh [kaM 7& ydM+h ds dk;Z c<+bZ
dk dke ds vUrxZr ekih tk;sxhA
?k dq,a dh xyh xksys dh nhokj dks izFkd ls [kaM 3& feh dk dk;Z
dh en 03004 ls 03008 esa ekik tk;sxkA dq,a ds ikV] c/kau NM+as
vkfn dks mi;qZDr [kaM ds vUrxZr ekik tk;sxkA
(c) Centering to arches, etc. shall be measured under
Section 7Woodwork (Carpenters work).
(d) Sinking of steining shall be measured separately vide
Items 03004 to 03008 of Section 3Earthwork. Well
curbs, tie-rods, etc. shall be measured under the
appropriate Sections.

In mud mortar

bZV
jfgr

05016 mMu jk[k bZVksa ls bZV


fpukbZ lek;kstu ij
6 eh ls vf/kd vkSlr
f=T;k dh lh/kh ;k
o fpukbZ
05017 mi;qZDr] o dk;Z esa
lek;kstu ij 6 eh
ls vuf/kd vkSlr
f=T;k dh
05018 mi;qZDr] xksy dwi
xksys esa fdlh f=T;k
ds] vk/kkj ;k o ls
fufeZr

izfr ?ku ehVj

M- e en 05016 ls 05024 b esa nh xbZ bZVksa dh njsa Js.kh laKk


75 75 fdxzk@lseh2 dh gSA
p vU; Js.kh laKk vFkkZr~ 125] 100] 50 buds fy;s vfrfjDr en
05032] o 05033 dh njksa dks nj 05019 esa tksM+k ;k ?kVk;k
tk;sxkA

Laid dry

xkjk elkyk

(e) Rates given in SI item 05016 to 05024 are for bricks of


class designation 75 (Kgf/cm2).
(f) For other class designation i.e.125, 100, 50 extra as
per SI item 05032, 05033 shall be added to/deducted
from SI item 05019.
PER CUBIC METRE

lw[kh fcNkbZ

Rs.

Old size Modular Except Old size Modular Except


bricks
bricks
bricks bricks
bricks
bricks

iqjkus eki ekiakd


dh bZV
bZV

428.50

bZV
jfgr

Rs.

iqjkus eki ekikad


dh bZV
bZV

1704.30

527.80

Rs.

1830.60 188.50 1531.10

1803.50

698.70

Rs.

1610.00

1876.90 234.80 1630.40

1974.50

Rs.

1656.30

2113.40 471.30 1801.40

Rs.

05017 Ditto, in curved


work on plan with
mean radius n. exc.

6m

1892.90

05016 Brickwork with


fly ash bricks
straight or curved
on plan exc 6 m
mean radius

05018 Ditto, in circular


well steining (any
radius) constructed from the base

or curb

SECTION 5

SECTION 5- BRICK WORK


[k.M 5 bZV dk dk;Z
BRICKWORK IN BURNT FLY ASH BRICKSContd...
nX/k mMu k[k bZVksa ls bZV fpukbZ tkjh
izfr ?ku ehVj

PER CUBIC METRE


05019 Brickwork with fly ash
bricks, straight or curved
on plan exc 6m mean
radius, built in

Old size bricks in cement mortar

Modular bricks in cement mortar

iqjkus eki dh bZVksa ls lhesaV elkyk esa

ekikad bZVks ls lhesaV elkyk es

1:8
Rs.
2162.70

1:8
Rs.
2316.20

1:6
1:4
Rs.
Rs.
2249.50 2421.20

1:3
Rs.
2520.50

1:6
Rs.
2392.40

1:4
Rs.
2551.90

1:3
Rs.
2688.30

05019 mMu jk[k bZVksa ls bZV


fpukbZ lek;kstu ij 6
eh ls vf/kd vkSlr f=T;k
dh lh/kh ;k o fpukbZ]
var% fufeZr
izfr oXkZ ehVj

05020 Brickwork with flyash


bricks, straight or curved
on plan to any radius i n
half brick thick walls,
built in

05020 mMu jk[k bZVksa ls bZV fpukbZ


lek;kstu ij fdlh Hkh
f=T;k dh vk/kh bZV dh
eksVkbZ dh lh/kh ;k o nhokj
dh bZ V fpukbZ dk;Z ]
varfufeZr
05021 mMu jk[k bZVksa ;k bZV
Vkbyksa lss [kMh+ bZV dh
nhokj esa bZV ls de
eksVkbZ bZV fpukbZ dk;Z]
varfufeZr
05022 mMu jk[k bZVksa ls ,d bZV
eksVkbZ dh djaMh Nrk
nhokjksa esa bZV fpukbZ dk;Z]
var% fufeZr
05023 mi;qZDr] vk/kh bZV eksVkbZ
dh dja M h nhokjks a es a ]
var% fufeZr
05024 mi;qDZ r] [kM+h bZV dh djaMh
nhokjksa esa vk/kh bZV ls de
eksVh var% fufeZr

05021 Brickwork with fly ash


bricks or brick tiles in brickon-edge walls (less than
brick thick),built in

05022 Brickwork with fly ash


bricks in one brick thick
honey-comb walling,

built in
05023 Ditto, in half-brick thick
hon-ey-comb walling

built in
05024 Ditto, in brick-on-edge
honey comb walling (less
than half brick thick),

built in

264.80

272.80

289.00

301.60

249.60

255.30

2267.10

280.40

198.60

202.20

208.60

215.80

241.50

246.20

255.90

294.70

373.90

379.80

393.40

404.20

359.30

364.10

375.60

384.50

185.30

188.30

194.10

199.00

170.30

172.30

177.60

181.40

146.10

147.50

150.30

152.70

61

PER SQUARE METRE

62

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
EXTRAS ON BRICK WORK
bZV fpukbZ dk;Z ij vfrfjDr
PER CUBIC METRE
Add to items 05004, 05010 and
05019 for
05025 Brickwork curved to plan
with mean radius n. exc. 6m
with bricks roughly cut to
radius or bricks with wedge

shaped joints
05026 Ditto with fair cut and rubbed
bricks or purpose moulded

bricks
05027 Brickwork in independent
chimney shafts (as for large
steam boilers), square,
rectangular or polygonal on

plan
05028 Dilto but curved on plan to

any radius
05029 Brickwork in underpinning to
walls in short lengths (labour
etc., cutting out old walls

measured separately)
05030 Brickwork in arches with
selected uncut bricks with

wedge shaped joints


05031 Brickwork in arches and
vaults with purpose moulded
or faircut and rubbed bricks
and joints of uniform

thickness
05032 For using bricks of class
designation 100 instead of

class designation 75
05033 For using bricks of class
designation 125 instead of

class designation 75

M&L
Clay bricks

lk ok Je

M&L
Flyash
bricks

Except
bricks

bZV jfgr

lk ok Je
Rs.

Rs.

Rs.

69.10

71.90

28.70

283.70

292.50

157.30

izfr ?ku ehVj


en 05004 o 05010 vkSj 05019
esa tksMsa
05025 lek;kstu ij vkSlru 6 eh ls vuf/
kd f=T;k dh bZV dh vle dkV ;k
QUuh vkdkj ds bZV tksM+ ds c bZV
fpukbZ dk;Z
05026 mi;qZDr] eghu dkV o f?klh bZVksa ;k
iz;kstu ls <yh gqbZ bZVksa ds lkFk
05027 LokoYkEch fpeuh fudkl tSls cM+sa
ok"i ok;yj ds fy;s lek;kstu ij
pkSdksj vk;rkdkj ;k cgqHkqth

257.20

257.20

257.20

492.80

501.80

367.80

662.80

662.80

662.80

267.90

276.70

141.60

730.60

738.60

604.10

70.75

70.75

05028 mi;qZDr] fdUrq lek;kstu ij fdlh


f=T;k dk o
05029 NksVh yEckb;ksa esa nhokjksa dh uhps dh
HkjkbZ vc iz"Bhdj.k Je vkfn] iqjkuh
nhokjksa dh dVkbZ izFkd eisxh
05030 pquh gqbZ fcuk dVh bZVksa esa Quuh
vkdkj ds tksMk+ as ds lkFk esgjkoksa esa bZV
fpukbZ dk;Z
05031 iz;kstu ls x<+h gqbZ ;k eghu dVh o
f?klh o leku eksVkbZ ds tksM+ksa lfgr
esgjkoksa o esgjkoh Nrksa esa bZV fpukbZ
dk;Z
05032 75 Js.kh in uke ds LFkku ij 100
Js.kh inuke dh bZV ds iz;ksx ds fy;s

05033 75 Js.kh in uke ds LFkku ij 125


Js.kh inuke dh bZV ds iz;ksx ds fy;s
141.00

141.00

63

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
BRICK WORK AROUND STEEL JOISTS, STANCHIONS ETC.
bLikr dh dfM+;kn] lhdapks vkfn
The girth of joists, stanchions, etc. shall be measured.
PER SQUARE METRE
05034 Extra over brickwork for labour in
cutting and building in brickwork
around steel joists, stanchions,

girders, etc.

(a)

(b)

Rs.

153.50

izfr oxZ ehVj


05034 vfrfjDr bLikr dfM+;ksa] lhdpksa] xkMjksa
vkfn ds pkjksa vksj bZV dk;Z esa dVkbZ o
cukoV ij vk;s vfrfjDr Je gsrq

CAVITY WALL
dkS V ju f>jhnkj nhokj
Area of cavity to be measured shall be the area of d dksVj ds dsUnz ij dfYir iz;kstu {ks= gh dksVj dk ekiu {ks=
the imaginary plane at the centre of the cavity,
gksxk] lHkh eks[kksa o nhokj ds Bksl Hkkx dh dVkSrh gksxhA
deduction being made for all openings and solid
portions of wall.
Brickwork in skins and solidly built portions shall
be measured under relevant items of brickwork.
PER CUBIC METRE

05035

dfM+;ksa] lhadpksa dk ?ksjk ekik tk;sxkA

Extra over brickwork for forming cavity


4 to 8 cm; with and including not less
than 5 numbers of bitumen coated
galvanised iron wall ties (20 mm x
5mm, 20cm long of approved pattern)
for 1 sq.metre, forming weep holes and

fixing only of gratings

[k mijh Hkkx o Bksl fufEkZr Hkkxksa ds bZV dk;Z dks bZV dk;Z dh
lacfU/kr enksa ds vUrxZr ekik tk;sxkA
izfr ?ku ehVj

Rs.

82.80

05035 vfrfjDr] ,d oxZ Ekh eas de ls de 5 rkjdksy


ysfir tLrsnkj yksgs ds nhokj ca/kd] vuqekfur
vkd`fr dh 20 feeh 5 feeh-] 20 lseh YkEch 4
ls 8 lseh- ds 1 oeh >jks[ks cukus ds dsoy tkyh
yxkus ds fy;s dksVj ij bZV dk;Z gsrq
iz f r ehVj

PER RUNNING METRE


05036 Extra over brickwork for closing cavity
at jambs, cills and heads of opening
etc. (supply and fixing of flashing etc.
not included)

128.40

05036 vfrfjDr] ik[kks]a flyksa o eks[ks ds 'kh"kksZa vkfn


ds dksVj can djus ds fy,] bZV dk;Z gsrq
tyjks/kh f>Yyh dh vkiwfk o LFkkiu vkfn
'kkfey ugha gSa

BRICK WINDOW CILLS, CORNICES, ETC.


bZV dh f[kM+dh ngyht] dkjful vkfn
PER CUBIC METRE
05037 Extra only on brickwork for splayed,
bull-nosed or any other type of
purpose-moulded bricks (volume of
purpose moulded bricks measured
ignoring all wants viz., splays,

grooves, chamfers, etc.)

Rs.

izfr ?ku ehVj


05037 vfrfjDr] dsoy piVh] dqCck ;k fdlh vU;
izdkj dh iz;kstu x<+h bZVksa gsrq lHkh dfe;ksa
tSls] piVkiu] [kkaps] i[k vkfn dks NksM+dj]
iz;kstu x<+h bZVksa dk vk;ru ekik tk;sxk

324.00

64

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
FAIR CUTTING ON BRICKWORK (ANY DESCRIPTION)
bZVksa dh ckjhd dVkbZ fdlh o.kZu dh
(Payable only when purpose made bricks are not used)

Hkqxrku dsoy rc tc iz;kstu cuh bZVksa dk iz;ksx u gks


(a) The rates are applicable to common bricks and facing
bricks.
(b) The girth measurement of all chases, grooves, rebates,
etc. shall be taken.
(c) The rates include for stops and mitres to chamfers,
rounded angles, splays, rebates, etc.
PER SQUARE METRE
05038 Fair cutting exc 10cm width or girth
on exposed surfaces of brickwork
as to fire place apertures, splayed
angles, weathering, cornices,
groins, etc. including rubbed finish

and waste

d ;g njsa lkekU; bZV ;k eksgjk bZVksa ij ykxw gSaA


[k ?ksjs dh eki esa lHkh fjfDr;ksa] [kkaps] irke vkfn fy;s tk;saxsA
x i[kksa] xksy dks.kksa] piVu] irkeksa dh HkjkbZ o dksfu;k bu njksa
esa 'kkfey gSaA

Straight or
raking cutting

Circular
cutting

lh/kh ;k frjNh
dkV

xksy dkV

Rs.

Rs.

170.50

313.30

izfr oxZ ehVj


05038 bZV dk;Z dh fn[kus okyh lrg tSls
vaxhBh ds }kj] frjNs dks.k <yku dkjful]
lfU/k;k vkfn ij jxM+ dj ifjLd`fr
djus o Nhtu lfgr 10 lseh ls vf/kd
pkSMh+ ;k ?ksjs dh ckjhd dVkbZ djuk
iz f r ehVj

PER RUNNING METRE


05039 Fair cutting n exc 10 cm width or girth
on exposed surfaces of brickwork
such as in splays, chamfers, etc.

including rubbed finish and waste

28.60

05039 bZV dk;Z dh fn[kus okyh lrg TkSls [kkapksa


ik[kksa vkfn ij jxM+ dj izfj"d`fr djus
ij Nhtu lfgr 10 lseh ls vuf/kd pkSMh+
;k ?ksjs dh ckjhd dVkbZ djuk

47.10

DAMP PROOF COURSES


vknzrk jks/kh LRkj
The rates for cement mortar and cement concrete damp proof lhesaV elkyk o vknzZrk jks/kh lhesaV dahV Lrj dh njksa esa] fuekZrk
courses include for incorporating integral water proofing ds crk;s x;s vuqikr esa rFkk fofunsZ'k ls iw.kZ vknzZrk jks/kh ?kksy dks
compound in the manner specified by the manufacturer and feykuk 'kkfey gSA njksa esa iw.kZ vknzZrk jks/kh ?kksy dh vkiwfk 'kkfey
in the proportions indicated. The rates do not include for the
ugha gS ftldh ;fn Bsdsnkj vkiwfkZ djsxk rks bldk Hkqxrku [kaM 4
supply of integral water proofing compound, which if
supplied by the contractor, shall be paid for in addition at dahV ds vUrxZr dsoy vkiwfk dh njksa ls gksxkA
supplied only rates under Section 4Concrete .
PER SQUARE METRE

05040 Damp proof course to


horizontal or vertical
surfaces including

necessary formwork

In cement mortar 1:2


lhesaV elkys esa 1%2

izfr oxZ ehVj

In cement concrete
1:2:4, type B-0
lhesaV dahV esa 1%2%4]
uewuk ch&0

15mm
thick
15 feeh
eksVk

20mm
thick
20 feeh
eksVk

25mm
thick
25 feeh
eksVk

40mm
thick
40 feeh
eksVk

Rs.

Rs.

Rs.

Rs.

92.30

124.20

80.20

133.10

05040 lh/kh likV lrg ij vko';d


Qjekoanh lfgr] vknzrZ k jks/kd ijr

65

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
DAMP PROOF COURSES Contd..
vknzrk jks/kh Lrj tkjh
tkjh..
Rs.
PER SQUARE METRE
izfr oxZ ehVj
05041 Applying evenly a coat of blown type
bitumen at the rate of 1.50 kg per square
metre and blinding with clean dry

sand @ 0.05 cu. m. per sq. m


05042 Polythene film, 50 micron thick, laid on
a coat of bitumen primer, @ 0.30 to 0.50

kg per sq. m

05043 Ditto, with 150 micron thick

05041 1-50 fdyks izfr oxZ eh ds fglkc ls Qqd


a s fdLe ds
Mkej dh ,d ijr yxkuk rFkk 0-05 izfr oxZ ehnj ls lkQ lw[kh jsr ls HkjkbZ djuk
05042 izfr oxZ eh ij 0-30 ls 0-50 fdyks dh 50 ekbksu eksVh
ikyhFkhu dh iV~Vh Mkej dh ,d ijr ij fcNkuk

98.40

35.60

05043 mi;qDZ r 150 ekbksu eksVh ikyhFkhu dh ih

50.90

CUTTING AND PINNING IN EXISTING WORK


fo|eku dk;Z esa dVkbZ o jsr HkjkbZ dk;Z
The girth of the chase shall be reckoned as that actually
required for the work, that is, maximum height of the
article or portion thereof inserted in the chase plus twice
the depth of insertion.
PER SQUARE METRE

Brick walls

bZV dh nhokj
05044 Cutting chases, pinning in, making
good to facings where required and
pointing in cement mortar 1:3 to
ends or edges of landings, steps,
cills, sunshades, shelves, lintels, etc.;
and cutting chases for concealed
water tubing or concealed conduit
wiring, etc. and making good,
cutting exceeding 20cm girth

[kkaps dk ?ksjk oSlk gh fu/kkZfjr fd;k tk;sxk tSlk fd dke ds fy;s


okLro esa pkfg;s] vFkkZr~ fufo"V oLrq ;k Hkkx dh vf/kdre mWpkbZ
tek fuos'ku dh xgjkbZ dk nqxukA

Stone concrete
block or slab
walls

Rs.

485.30

izfr oxZ ehVj


05044 [kkaps cukuk] HkjkbZ djuk rFkk vko';drkuqlkj
iz"B lrg dks Bhd djuk rFkk 1%3 ds
iRFkj] dahV
pkSds ;k ifV;k
elkys ls] vk/kkjksa] lhf<+;ksa] flyksa] Nkrksa]
nhokj
'kSYQksa fyVayksa vkfn ds Nksjksa fdukjksa esa Vhi
Rs.
djuk] rFkk ikuh uyksa o <dh rkj ufy;ksa
vkfn ds fy;s [kkaps cukuk rFkk 20 lseh ls
vf/kd ds ?ksjs dh dVkbZ Hkjuk
529.80

PER RUNNING METRE


05045 Cutting chases, pinning in. making
good to facings where required and
pointing in cement mortar 1:3 to
ends or edges of landings, steps, cills,
sunshades, shelves, lintels, etc.; and
cutting chases for concealed water
tubing or concealed conduit wiring,
etc., and making good, cutting not

exc 10 cm girth
05046 Ditto, exc 10 cm but not exc 20 cm

girth

85.80

93.70

121.50

132.10

iz f r ehVj
05045 [kkaps cukuk] HkjkbZ djuk rFkk vko';drkuqlkj
iz"B lrg dks Bhd djuk rFkk 1%3 ds elkys
ls] vk/kkjksa] lhf<+;ksa flyksa] Nkrksa] 'kSYQksa]
fyVayks vkfn ds Nksjksa fdukjksa esa Vhi djuk]
rFkk ikuh uyksa o <dh rkj ufy;ksa vkfn ds
fy;s [kkaps cukuk rFkk 10 lseh ls vuf/kd
ds ?ksjs dh dVkbZ Hkjuk
05046 mi;qZDr] ?ksjk 10 lseh ls vf/kd fdUrq 20
lseh ls vuf/kd

CUTTING HOLES FOR BOLTS, PIPES, JOISTS, AIR FLUES, VENTILATORS, CAST IRON BOXES ETC.,
AND MAKING GOOD TO EXISTING WORK

dkoyksa] uyksa] ik[kksa] ok;q /kaqvkjs jks'kunkuksa <ys yksgs dh isfV;ksa vkfn esa Nsn fudkyuk rFkk
fo|eku dk;Z dks Bhd cukuk
(a) The items for cutting and making good shall be d dVkbZ djus o HkjkbZ djus dh njsa dsoy rHkh ykxw gksxh tc
allowed only when openings etc. are cut in the old
eks[ks vkfn iqjkuh nhokjksa esa dkVh tkrh gSA
walls. The rates include for pinning in joists,
cantilevers, etc., spacing at proper distances,
levelling, etc., and removing rubbish off the premises.

66

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
CUTTING HOLES FOR BOLTS, PIPES, JOISTS, AIR FLUES, VENTILATORS, CAST IRON BOXES ETC.,
AND MAKING GOOD TO EXISTING WORKContd..

dkoyksa] uyksa] ik[kksa] ok;q /kaqvkjs jks'kunkuksa <ys yksgs dh isfV;ksa vkfn esa Nsn fudkyuk rFkk
fo|eku dk;Z dks Bhd cukuk tkjh
(b) Superficial area means net area of opening actually
required as follows :
In the case of wood joists, rolled steel joists, T or L
steel cantilever ends, etc., the dimensions taken are
to be the extreme width multiplied by the depth of the
joists, etc. For bars, bolts, pipes, etc. the external dia
is to be squared. For ventilating openings, air flues,
etc. the actual finished area of opening is to be
measured but allowance shall be made in the
measurements for the thickness of rendering ordered.
(c) If a wall is plastered, rendered or rough-cast, the full
thickness of wall including plastering etc. is to he
measured.
(d) The rates include for making good to the original
surfaces of any description disturbed, except any
painting or decorating that may be required.
(e) If cement concrete walls, canopies, chajjas, etc. are
reinforced with steel, an addition of 50 per cent is to
be made to the rates.
(f) Fixing of gratings, soot doors, etc. and rendering
flues (when ordered) shall be measured separately.
(g) Openings over 0.10 sq. m superficial area are to be
measured under the respective table for Cutting
openings for doors, etc., in Section 4Concrete,
Section 5 Brickwork or Section 6Stone masonry,
as applicable.
PER CENTIMETER OF
DEPTH (OF CUTTING)

Superficial area

[k

lrgh {ks= dk vFkZ gS] okLro esa vko';d eks[ks dk fo'kq) {ks=
tSls fd %&
ydM+h dh dM+h] csfYyr bLikrh /kju T ;k L bLikr izkl
fdukjs vkfn ds ekeys esa fy;k x;k ifjeki gksrk gS vf/kdre
pkSMk+ bZ xq.kk /kju@dM+h dh xgjkbZ@NM+k]as dkoyks]a uyksa esa
ckgjh O;kl oxkZdkj fy;k tkrk gSA jks'kunku fpefu;ksa vkfn
ds eks[ks ds fy;s eks[ks dk okLrfod {ks= ekik tk;sxk fdUrq
vkns'k ij iyLrj dk;Z dk vfrfjDr fn;k tk;sxkA

;fn nhokj ij iyLrj fyikbZ ;k eksVh x<k+bZ dh tkrh gS] rks


iyLrj vkfn lfgr iwjh nhokj ekih tk;sxhA

?k

bu njksa esa ewy nhokj esa vk;s fdlh Hkh izdkj ds fo?kVu dks
Bhd djuk 'kkfey gS flok; fdlh jaxjksxu ;k ltkoV ds]
tks visf{kr gks ldrh gSA
;fn lhesaV dahV dh nhokjsa] eqaMsjs] NTtk vkfn bLikr ls
ofyr gSa rks njksa esa 50 izfr'kr vf/kd fn;k tk;sxkA

M
p
N

tkyh] dtyh }kj vkfn yxkus o fpeuh dh fyikbZ djus


tc vkKk gks ds dk;Z izFkd ekis tk;saxsA
0-10 oxZ ehVj ls vf/kd ds lrgh {ks= ds eks[ks] **eks[ks dVkbZ
}kj vkfn ds fy;s** [kaM 4& dahV] [kaM 5& bZV dk dk;Z ;k
[kaM 6& iRFkj dh fpukbZ dh tks Hkh ykxw gksrh gS lacfU/kr
rkfydk esa ekik tk;sxkA
lrgh {ks=

N exc 150 Exc. 150 sq. cm Exc 400 sq. cm


sq. cm
but n exc 400 but n exc 0.10
150 oxZ
sq. cm.
sq.m.
05047 Cutting holes into or
lseh ls
150 ls vf/kd
400 ls vf/kd
through brick walls
vuf/kd
ijUrq 400 oxZ
ijUrq 0-10 oxZ
built in mud mortar and
lseh ls vuf/kd
eh ls vuf/kd
making good in cement
Rs.
Rs.
Rs.
mortar 1:3 or cement
concrete 1:2:4 type B-l as

required
2.30
3.50
6.70
05048 Ditto, but in brick walls
built in lime mortar and
stone walls built in mud
3.20
5.80
6.40

mortar

izfr lseh xgjkbZ dkV dh

05047 feh xkjs esa fpuh bZV dh nhokj esa


;k vkjikj] Nsn dkVuk rFkk 1%3
ds lhesaV elkys ;k ch 1 Js.kh
1%2%4 dh lhesVa dahV tSlh vis{kk
gks] ls Bhd djuk

05048 mi;qDZ r] fdUrq pwuk elkys esa fpuh


bZV dh nhokjsa o feh xkjs esa cuh
iRFkj dh nhokjsa

67

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
CUTTING HOLES FOR BOLTS, PIPES, JOISTS, AIR FLUES, VENTILATORS, CAST IRON BOXES ETC.,
AND MAKING GOOD TO EXISTING WORKContd..

dkoyksa] uyksa] ik[kksa] ok;q /kaqvkjs jks'kunkuksa <ys yksgs dh isfV;ksa vkfn esa Nsn fudkyuk rFkk
fo|eku dk;Z dks Bhd cukuk tkjh
lrgh {ks=

Superficial area
PER CENTIMETER OF
DEPTH (OF CUTTING)
05049 Ditto, but in brick walls
built, in cement mortar
or cement lime mortar
and stone walls built in
lime mortar or walls of

lime concrete.
05050 Ditto, but in stone walls
built in cement mortar or
cement lime mortar and
walls of cement con
crete.

Nexc 150
sq. cm
150 oxZ
lseh ls
vuf/kd

Exc 150 sq. cm Exc 400 sq. cm


but n exc 400 but n exc 0.10
sq cm
sq.m.
150 ls vf/kd
400 ls vf/kd
ijUrq 400 oxZ
ijUrq 0-10 oxZ
lseh ls vuf/kd
eh ls vuf/kd

Rs.

Rs.

Rs.

3.80

6.30

8.20

izfr lseh xgjkbZ dkV dh


05049 mi;qDZ r] fdUrq lhesVa elkys dh ;k
lhesaV pwuk bZV dh nhokjksa esa rFkk
pwuk elkys ls cuh iRFkj dh nhokjksa
;k pwuk dahV dh nhokjksa esa

4.90

8.10

10.50

05050 mi;qDZ r] fdrq lhesVa elkys ;k lhesVa


pwuk elkys ls cuh iRFkj dh nhokjsa
rFkk lhesaV dahV dh nhokjksa esa

CUTTING OPENINGS FOR DOORS, WINDOWS, ETC. AND MAKING GOOD


njokts f[kM+fd;ksa vkfn ds fy;s dVkbZ djuk o Bhd djuk
(a) The amount of cutting measured shall be the net size
of the finished opening irrespective of the amount of
walling actually cut out. The net cubic contents of cills,
bressummers, lintels, arches, etc. shall be allowed in
addition. The thickness of wall measured shall be
exclusive of plastering, rendering, rough-cast, etc.
(b) If existing openings are enlarged, the net contents of
the original opening shall be deducted from the net
contents of the new opening.
(c) The area payable for forming jambs shall be the net area
(excluding the thickness of plaster) of the inner vertical
sides of the opening. The rates for forming jambs include
for cutting, toothing and bonding the new to old.
(d) For making good to heads and cills, the length plus
depth at each end, shall be multiplied by the thickness
of wall. The rates for making good include for cutting
and pinning in cills, heads, lintels, bressummers, etc.
(e) The following shall be measured separately:
(1) New arches.
(2) New cills, heads, lintels, girders, etc., and hoisting
and setting same (but not cutting and pinning).
(3) The cost at supplied only rates of any new materials (except lime or cement mortar) required for
making good, namely bricks, blocks, stone, etc.
The old bricks, blocks, or stone cut out are
however, to be re-used, as far as practicable.
(4) Making good plastering, rendering, etc., around
the finished opening.

d ekih tkus okyh dVkbZ dh ek=k] okLro esa dkVh xbZ ek=k dk
/;ku fd;s fcuk laifw jr eks[ks dh fo'kq) eki gksxhA

[k ;fn iqjkus eks[ks dk c<+k;k tkrk gS rks u;s eks[ks esa ls iqjkus eks[ks
dh fo'kq) eki ?kVk nh tk;sxhA
x ik[kksa dks cukus ds ns; {ks=] eks[ks dh vUnj dh lekukUrj
Hkqtkvksa dk fo'kq) {ks= gksxkA ik[kksa dks cukus dh njksa esa dVkbZ]
nkUr cukus o u;s dks iqjkus ls tksM+us ds dk;Z 'kkfey gSaA
?k

'kh"kksZ o ngyhtksa dks cukus ds fy;s izR;sd fdukjs dh xgjkbZ


tek yEckbZ dks nhokj dh eksVkbZ ls xq.kk fd;k tk;sxkA Bhd
djus ds dke dh njksa esa] ngyhtksa] 'kh"kksZ] fyVyksa] ikVfM+;ksa
vkfn esa dVkbZ o HkjkbZ 'kkfey gSA
fuEu dks izFkd ekik tk;sxk%&
1 uohu MkVsa esgjkosaA
2 ubZ ngyhtsa] 'kh"kZ] fyaVy] xkMZj vkfn rFkk mudks
mBkuk yxkuk fdUrq dVkbZ HkjkbZ ughaA
3 ubZ lkexzh dh **dsoy vkiwfrZ** dh ykxr pwuk ;k lhesVa
elkyk jfgr ftldh ifj"d`fr esa vko';drk gksxh tSls
bZV]as pkSds iRFkj vkfn A iqjkuh bZV]as pkSds ;k dVs iRFkj
vkfn dks tgka rd laHko gks iqu% iz;ksx fd;k tk;sA
4 laiwfjr eks[ks ds pkjksa vksj ds iyLrj] fyikbZ dk;Z dks
Bhd djukA

68

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
CUTTING OPENINGS FOR DOORS, WINDOWS, ETC. AND MAKING GOOD Contd..
njokts f[kM+fd;ksa vkfn ds fy;s dVkbZ djuk o Bhd djuk& tkjh-PER CUBIC METRE
05051 Cutting openings, through
brick walls for door, window
and other openings or
enlarging existing openings.
converting window into door
openings, etc. or cutting out
defective brick work for
under-pinning, including
providing, fixing and
removing shoring, cleaning
and
stacking
bricks,
removing
surplus
serviceable bricks, hard-core,
etc.. to store and rubbish not

exc. 50m

PER SQUARE METRE


05052 Forming jambs, etc. to
openings (to foregoing
item), including cutting,
toothing
and properly
bonding into old work,
also facing, jointing and
pointing to match existing

work, complete
05053 Making good under cills or
over arches, lintels and bressummers. including allpinning when necessary

Brick wall Add if build


Add if built in
built in mud
in lime
cement mortar or
mortar
mortar
cement lime mortar
xkjs dh bZV
tksM+sa pwuk
tksMsa ;fn lhesaV@pwuk
nhokj
elkys ds fy,
lhesaV elkyk
Rs.

Rs.

Rs.

284.80

117.30

234.80

Lime
mortar 1:3
mortar
pwuk eklyk
1%3

Cement
Cement mortar 1:4
mortar 1:6 or
or cement lime
cement lime
mortar 1:2:9
mortar 1:1:8
lhesaV elkyk
lheasV elkyk 1%4 ;k
1%6 ;k lhesaV
lhesaV pwuk elkyk
pwuk elkyk
1%2%9
1%1%8

Rs.

Rs.

Rs.

299.70

380.30

469.00

146.10

210.70

264.90

izfr ?ku ehVj


05051 njokts f[kM+fd;ksa ;k vU; ds
fy;s nhokj esa vkjikj eks[ks]
dVkbZ ;k iqjkus eks[ks] f[kM+dh
dks njokts esa cnyus ds fy,
c<+kuk ;k v/kHkjkbZ ds fy;s nks"kiw.kZ
dk;Z dks rksMu+ k esa Vsd canh dh
O;oLFkk djuk yxkuk o gVkuk
lQkbZ djuk lfgr rFkk bZVksa
dks lafpr djuk] Qkyrw mi;ksxh
bZVks]a dBksj rRoksa vkfn dks Hk.Mkj
esa igap
q kuk rFkk eyos dks 50 eh
vuf/kd LFkku ij Qsd
a uk
izfr oxZ ehVj
05052 dVkbZ] nkars fudkyuk o iqjkus
dke esa yxkus lfgr eks[kksa esa
fiNyh en ds ik[ks vkfn
dk cukuk rFkk lrg Hkh] tksMu+ k
o iqjkus dk;Z ls esy [kkrh
Vhi djuk vkfn laiw.kZ

05053 ngyht ds uhps ;k MkV fyVy


o ikVdM+h ds ij ds Hkkxksa dks
tgka vko';d gks ogka HkjkbZ djus
lfgr] ifj"r djuk

FIXING HOLDFASTS IN JAMBS OF EXISTING OPENING AND MAKING GOOD


fo|eku eks[kksa esa ik[kksa esa idM+ ikh yxkuk o ifj"d`r djuk
(a) The rates do not include cost of holdfasts which shall
be measured separately.

(b) Making good includes for making good with serviceable old/new bricks/stone to match the adjoining
work.
(c) The contractor may dismantle brickwork as
alternative to cutting at his option. In that case he
will make good with serviceable old/new brick to
match with adjoining work. The rate shall include
the above element.

[k
x

njksa esa idM+ ikh dh ykxr 'kkfey ugha gS mUgsa izFkd ekik
tk;sxkA
*ifj"d`r* djus esa LkkFk ds dk;Z ls feykrs gq, mi;ksxh
iqjkuh@ubZ bZVks@
a iRFkj lfgr ifj"d`r djuk 'kkfey gSA
Bsdns kj vius foosd ls bZV dk;Z dks dVkbZ ds fodYi ds :i
esa m[kkM+ ldrk gSA bl voLFkk esa og lkFk ds dk;Z ls
feykrs gq;s mi;ksxh iqjkuh@ubZ bZVksa ls izfj"d`rh djsxk] njksa
esa ;g rRo 'kkfey gSaA

69

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
FIXING HOLDFASTS IN JAMBS OF EXISTING OPENING AND MAKING GOOD Contd..
fo|eku eks[kksa esa ik[kksa esa idM+ ikh yxkuk o ifj"d`r djuk& tkjh-EACH

iz R ;s d

Depth of embedded portion of holdfasts or


lugs measured from the face of the jamb
into the wall

idM+ ikh ds vUnj yxs Hkkx ;k vyx dh xgjkbZ


ik[k ls nhokj ds vUnj ekih tk;sxh
Not exc.
half brick
05054 Cutting holes in brick
walls in mud mortar for
inserting holdfasts and
making
good
dismantled portion in
cement mortar 1:3 or
cement concrete 1:2:4
Type B-1 as required
05055 Ditto, but in brick walls
built in lime mortar and
stone walls built in mud

mortar
05056 Ditto, but in brick walls
built in cement mortar or
cement lime mortar and
stone walls built in lime
mortar

05057 Ditto but in stone walls


built in cement mortar or
in cement lime mortar

vk/kh bZV ls
vuf/kd

Exc. half brick


Exc. one
but not exc.
brick but not
one brick
exc. two bricks

vk/kh ls vf/kd
,d ls vuf/kd

05054 feh xkjs dh bZV nhokj esa idM+


ikh yxkus ds Nsn dkVuk rFkk
,d bZV ls
[kksns x;s Hkkx dks 1%3 ds lhesaV
vf/kd nks ls
elkys ls ifj"d`r djuk
vuf/kd

Rs.

Rs.

Rs.

30.90

60.20

79.10

45.30

89.40

117.50

45.30

104.20

136.40

53.70

105.70

156.20

05055 mi;ZDq r] fdUrq pwuk elkyss esa cuh bZV


nhokj o xkjs esa cuh iRFkj dh nhokj
esa
05056 mi;qZDr] fdUrq lhesaV elkys ;k
pwuk lhesaV elkys esa cuh bZV dh
nhokj rFkk pwuk elkys esa cuh
iRFkj dh nhokj esa

05057 mi;qZDr] fdUrq lhesaV elkys ;k


lhesVa pwuk elkys esa cuh iRFkj dh
nhokj esa

CUTTING AND FACING WALLS, ETC.


dVkbZ dk;Z rFkk eksgjk nhokjsa vkfn
(a) The rates in this table include for facing with selected
bricks, and jointing and pointing complete.

(b) Pointing shall be in the same mortar as used in facing


except in the case of brick, set in mud mortar, pointing,
if ordered, shall be measured separately.

[k

(c) The rates also include for cleaning and stacking


bricks, removing serviceable bricks, hard-core etc. to
store and rubbish off the premises, n. exc. 50m.

(d) The length of new wall shall be measured from the


existing face of old wall.

?k

bl rkfydk dh njksa esa eksgjksa ds fy;s bZVas pwukuk rFkk tksMu+ k


o Vhi djds laiwfrZ 'kkfey gSA
eksgjksa esa iz;qDr elkys ls gh Vhi gksxh flok; tgka bZVsa xkjs
esa yxh gks] ogka ;fn Vhi djus dh vkKk nh tkrh gS rks
mldh eki izFkd gksxhA
njkssa esa bZVksa dks lkQ djuk lap; djuk mi;ksxh bZVks]a dBksj
rRoksas vkfn dks Hk.Mkj esa igqpkuk o eYos dks 50 eh ls
vuf/kd nwjh ij Qsaduk 'kkfey gSA
ubZ nhokj dh yEckbZ nhokj ds fo|eku Lrj ls ekih tk;sxhA

70

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
CUTTING AND FACING WALLS, ETC.Contd.
dVkbZ dk;Z rFkk nhokjksa dh lajpuk & tkjh
Old brick walls built in
Mud Mortar
PER SQUARE METRE
05058 Cutting out bricks,
forming toothing for,
and bonding new into
old work including
value of new materials entering old
walls and jointing and
pointing (measured
on vertical face in
contact with old wall

only)

lhesVas
elkyk

lhesVas
elkyk

lhesVas
elkyk

1:6

1:4

1:3

Rs.

Rs.

Rs.

286.20

291.70

296.50

feh xkjs esa cuh iqjkuh nhokjsa


izfr oxZ ehVj
05058 bZVksa dh dVkbZ djuk]
nkars cukuk o u;s dk;Z
dks iqjkus ls tksM+uk
iqjkuh nhokj ds vUnj
yxh ubZ lkezxh ds ewY;
o Vhi djus lfgr
iqjkuh nhokj ds laidZ
esa likV lrg dsoy
ekih tk;sxh u;k dk;Z
vr%fufeZr

696.10

izfr oxZ ehVj


05059 [kjkc gq b Z bZ V ks a dks
fudkyuk rFkk ubZ bZVksa
dh lajpuk djuk ,d
rksM+s ls 3 iV~Vh jn~nk
rFkk ifjd`r djuk]
var% fufeZr

New Work built in


u;s dk;Z esa
Mud
Lime
Cement Cement Cement Cement
Mortar Mortar
Lime Mortar Mortar Mortar
1:3
Mortar
1:6
1:4
1:3
1:1:6

xkjk
elkyk

pwuk
elkyk
1%3

lhesVas
pwuk
elkyk

Rs.

Rs.

1:1:6
Rs.

271.40

282.70

289.80

PER SQUARE METRE


05059 Cutting out decayed
brickwork and
refacing with new
bricks (1 course of
headers to 3 courses
of stretchers) and
making good

542.60

613.30

648.30

644.50

672.20

824.70

901.10

944.90

1003.30 1048.20

351.60

358.70

376.80

382.30

387.10

izfr 100 ua05060 iqjkuh nhokj esa ls [kjkc gqbZ


bZVksa dks dkV fudkyuk rFkk
mlesa cus isou tks izR;sd 7
bZVksa ls vf/kd dk u gks esa ubZ
bZVa s yxkdj izfjd`r djuk]
u;k dk;Z var%fufeZr
pwuk elkys esa cuh iqjkuh
bZV dh nhokjsa
fr oxZ ehVj
05061 lc ogh tks en 05058 esa gS

661.70

697.10

692.90

720.50

744.50

05062 lc ogh tks en 05059 esa gS

873.10

943.90

993.90

1048.30 1096.50

05064 All as per Item 05058

399.30

404.30

409.60

05065 All as per Item 05059

715.40

743.00

767.00

1017.00

1072.00 1119.00

PER 100 NOS.


05060 Cutting out decayed
bricks from old walls
and making good
with new bricks in
detached patches of
not more than 7
bricks each patch
Old brick walls built in
Lime Mortar
PER SQUARE METER
05061 All as per Item 05058
05062 All as per Item 05059
PER 100 NOS.
05063 All as per Item 05060
Old brick walls built in
cement or Cement Lime
Mortar

711.00

PER SQUARE METRE

PER 100 NOS


05066 All as per Item 05060

fr 100 ua05063 lc ogh tks en 05060 esa gS


lhesaV ;k lhesaV pwuk esa
cuh iqjkuh bZV dh nhokjsa
fr oxZ ehVj
05064 lc ogh tks en 05058 esa gS
05065 lc ogh tks en 05059 esa gS
fr 100 ua05066 lc ogh tks en 05060
esa gSA

71

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
FILLETING
ifk;ka cukuk
njksa esa i`B lrg dks ifjd`r djuk kkfey gSA
The rates include for fair finish to exposed surfaces.
Section of fillet
Add in if
PER RUNNING METRE
iz f r ehVj
irh dh dkV

05067 Filleting in any position


and to any shape in cement
lime mortar 1:1:6 including
all mitres, stops, etc.
05068 Ditto in cement mortar 1:4
05069 Ditto in cement mortar 1:3

repairs

N exc. 25 sq

Exc. 25 but n

tksM+sa ;fn

cm

exc. 50 sq. cm

ejEer esa

vuf/kd 25 oxZ

25 ls vf/kd o

lseh
Rs.
20.30

50 lseh ls vuf/kd
Rs.
26.50

Rs.
1.00

20.80
22.00

27.00
29.00

1.60
3.20

05067 fdlh Hkh fLFkfr o vkdkj es]a lHkh


dksfu;ka] fojke vkfn lfgr 1%1%6 ds
lhesVa pwuk elkys ls iV~Vh cukuk
05068 mi;ZDq r fdUrq 1%4 ds lhesVa elkys esa
05069 mi;ZDq r fdUrq 1%3 ds lhesVa elkys esa

BEDDING AND POINTING FRAMES IN EXITING OPENINGS


fo|eku [kqys LFkku esa pkS[kV yxkuk o Vhi djuk
PER RUNNING METRE

iz f r ehVj

Rs.

05070 Bedding and pointing timber door


or window frames (chowkats) in

cement mortar 1:3


05071 Bedding and pointing steel doors
and window frames (except pressed
steel frames) in cement mortar

1:3

17.00

05070 ydM+h dh njokts ;k f[kM+dh dh pkS[kV 1%3 ds lhesVa


elkys esa yxkuk o Vhi djuk
05071 bLikr ds njokts o f[kM+fd;ksa ds se nko bLikr se
ds vykok 1%3 ds lhesVa elkys esa yxkuk o Vhi djuk

13.80

FI XING ONLY GRATINGS, SOOT DOORS, ETC. IN EXISTING WORK


fo|eku dk;Z esa tkyh] dtyh njokts vkfn dsoy yxkuk
PER 100 NOS

Area n exc
400sq.cm

Area exc 400


but n exc.

Area exc
1000sq.cm

{ks+= vuf/kd

1000 sq.cm

{ks= 1000 oxZ

400 oxZ lseh

{ks= 400 ls vf/kd

lseh ls vf/kd

fr 100 ua-

1000 oxZ lseh ls


05072 Fixing only gratings,
soot doors, etc., including
bedding and pointing in

cement mortar 1:3


05073 Ditto, but in repairs,
including cutting out
old and removing to
store

vuf/kd
Rs.

Rs.

Rs.

1618.40

2443.20

3333.40

2081.30

2906.20

3796.40

05072 dsoy tkyh] dtyh njoktksa vkfn


dks 1%3 ds elkys esas dsoy yxkuk
o Vhi djuk
05073 mi;ZqDr] fdUrq ejEer esa] iqjkus
dks dkV fudkydj Hk.Mkj igqp
a kuk
lfgr

72

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
FIREBRICK WORK
vfXu&lg bZV dk;Z
(a) All firebrick work shall be measured net without any
allowance for cutting and waste. Flues shall be deducted.
(b) The rates include for forming cavity between fire brick
lining and brickwork.

d vfXu lg bZV fpukbZ dh] fcuk dVkbZ o Nhtu dk vfrfjDr


yxk;s fokq} ekik tk;sxkA /kq;s ds Nsn ?kVk;s tk;saxsA
[k njksa esa bZV ds vLrj o fpukbZ ds chp esa dksVj cukuk kkfey gSA

M&L
Except fire bricks
izfr ?ku ehVj
lkexz
h
o
Je
vfXulg
bZ
V
jfgr
05074 Firebrick work in linings to fire
05074 pwYgks]a fpefu;ksa vkfn ds vLrj esa vfXu
places, flues, etc. (other than in
Rs.
Rs.
lg bZV fpukbZ dk;Z] fpeuh kSVksa ds
chimney shafts), set, jointed and
vykok fcBkuk] tksM+uk rFkk vfXulg
2204.00
13241.50
pointed in fireclay
feh ls Vhi djuk
12206.20
05075 Ditto in lining to chimney shafts
05075
mi;ZqDr] fpeuh kSVks ds vLrj esa
2613.10
PER CUBIC METRE

ACID RESISTING BRICKWORK


vEy izfrjks/kh bZV dk;Z
Acid resisting brick work shall be measured net without
any allowance for cutting and waste.
PER SQUARE METRE

In lime

vEy izfrjks/kh bZV dk;Z fcuk dVkbZ o Nhtu ds fy;s vfrfjDr


fokq) ekik tk;sxkA
fr oxZ ehVj

In cement Taking and re-

mortar 1:2 mortar 1:3 moving rubbish


pwuk elkyk

05076 Broken glass


top of walls

coping on

lhessaV elkyk

eyok fudkyuk o

1:2

1:3

gVkuk

Rs.

Rs.

Rs.

232.60

301.50

25.60

05076 VwVs dkap nhokj ds mij yxkuk

SWEEPING CHIMNEY FLUES


fpeuh /kqvkn ekxZ lkQ djuk
(a) The rates include for removal of all soot and other
obstruction and keeping rooms and all articles therein clean
and free from soot, etc., and making good damage to the
same.
(b) The rates apply to flues commencing from any floor (that is
ground floor, first floor, second floor, etc.) to the top of
chimney stack.
EACH
05077 Sweeping chimney flues of any section

or length

d njksa esa lHkh dkfy[k o vU; :dkoVsa gVkuk rFkk dejksa o lHkh
mldh oLrqvksa dks lkQ o dkfy[k vkfn ls jfgr j[kuk rFkk
mlesa gq;s uqdlku dks iwjk djukA
[k njsa fdlh Hkh ry ls vk jgs /kqvk ekxZ ls vFkkZr~ Hkwfe ry] izFke
ry] f}rh; ry vkfn ls fpeuh dh pksVh rd ij ykxw gksrh
gSA

Rs.
24.80

R;s d
05077 fpeuh ds fdlh Hkh dkV ;k yEckbZ ds /kqvk
ekxZ dks lkQ djuk

73

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
BRICK EDGINGS
bZV dh fdukjs canh
The rates include for embedding bricks in the ground to depths
indicated and tamping ground around bricks and also for removing any surplus spoil, etc
PER RUNNING METRE

05078 Continuous brick edging;


with width equal to the
depth of the brick, laid

dry, on edge
05079 Ditto but laid on end verti
cally
05080 Ditto but laid on end at the

required angle
05081 Continuous brick edging;
with width equal to the
width of the brick; laid dry

on end vertically
05082 Ditto but laid on end at the

required angle
05083 Continuous brick edging;
with width equal to the
length of the brick; laid
dry on edge vertically
05084 Ditto but laid on edge at

the required angle

With burnt clay bricks


of sub class B

njksa esa crkbZ xgjkbZ rd bZVksa dks tehu esa yxkuk rFkk bZVksa ds pkjksa
vksj dqVkbZ djuk rFkk fdlh Hkh izdkj ds dwMs+ dks gVkuk kfey gSA

MMu jk[k ls cuh bZVksa ls

pduh feh ls cuh ch


Js.kh dh bZVksa ls
Old size
Bricks
13.30

Modular
Bricks
14.40

Old size
Bricks
14.00

Modular
Bricks
15.30

28.00

28.80

29.60

30.50

20.40

21.50

45.30

47.80

45.30

33.20

35.00

45.90

48.40

38.50

23.00

iz f r ehVj

With fly ash bricks

40.30

0507
050788 bZV dh vfojy fdukjs canh esa bZV
dh xgjkbZ ds cjkcj dh pkSMk+ bZ esa
*ch* miJs.kh dh iwjh bZV dks tehu
esa lw[kh [kM+h yxkuk
05079 mi;ZqDr] fdUrq likV fdukjs
ls mnxz likV yxkuk
05080 mi;ZqDr] visf{kr dks.k ij
mnxz yxkuk
05081 bZV dh vfojy fdukjs canh esa
bZV dh pkSMk+ bZ ds cjkcj pkSMk+ bZ
esa ch miJs.kh dh iwjh bZV lw[kh
mnxz likV yxkuk
05082 mi;qZDr] fdUrq visf{kr dks.k
ij mnxz yxkuk
05083 bZV dh vfojy fdukjs canh esa bZV
dh yEckbZ ds cjkcj pkSMk+ bZ esa iwjh
bZV dks likV [kM+h yxkuk
05084 mi;qZDr] fdUrq visf{kr dks.k
ij [kM+h yxkuk

BRICKWORK IN BURNT CLAY SEWER BRICKS


nX/k fpduh eh lhoj bZVksas ls bZV fpukbZ
(a) Bricks shall be burnt clay sewer bricks conforming to
IS-4885.
(b) The rates for work curved or polygonal on plan include for
all extra cutting and extra waste in the body of the work. It
shall be measured as mean length of wall.
(c) Centering to arches, etc. shall be measured under Section
7Woodwork (Carpenters work).
(d) Average compressive strength of sewer bricks shall be not
less than 175 ( Kgf/cm2 ) and individual compressive
strength of any sewer brick shall be not less than 160
(Kgf/cm2 ).
(e) The average value of water absorption shall not exceed
10% of average dry weight of brick and water absorption
for any individual brick shall not exceed 12%.
(f) The rating of efflorescence shall not be more than slight.

d bZVksa Hkk ek&4885 ds vuqlkj lhoj ds fy, nX/k fpduh feh


ls cuh gksxhA
[k o ;k cgqHkqth vk;kstu dk;Z dh njksa esa lHkh vfrfjDr dVkbZ
o vfrfjDr Nhtu kkfey gSA ;g nhokj dh e/; yEckbZ tSls
ekik tk;sxkA
x esgjkoksas MkV vkfn dh <wykcanh [kaM 7& ydM+h ds dk;Z c<+bZ
dk dke ds vUrxZr ekih tk;sxhA
?k lhoj bZVksa dh vkSlr ncko es kkfDr 175 fdxzk@lseh 2 ls
de ugha gksxh vkSj vdsyh nokc es kfDr fdlh Hkh bZV dh 160
fdxzk@lseh 2 ls de ugha gksxhA
M ikuh lks[kus dh vkSlr {kerk bZVksa ds vkSlr lw[ks otu ds 10
ls T;knk ugha gksxh vkSj fdlh Hkh ,d bZV ds fy, ikuh lks[kus
dh {kerk 12 ls T;knk ugha gksxhA
p Qwyus dh nj lw{e ls T;knk ugh gksxhA

74

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
BRICKWORK IN BURNT CLAY SEWER BRICKS Contd...
nX/k fpduh eh lhoj bZVksas ls bZV fpukbZ& tkjh--PER CUBIC METRE
05085 Brickwork with sewer
bricks straight or curved
on plan exc 6 m mean
radius for man-holes/
septictank/ soakwell etc.

in sewer works
05086 Ditto, in curved work on
plan with mean radius n.

exc. 6 m

In cement mortar 1:4

In cement mortar 1:3

lhesaV elkyk 1%4 esa

lhesaV elkyk 1%3 esa

M&L

Except
bricks

M&L

Except
Bricks

lkexzh o
Je

lkexzh o Je

bZV jfgr

Rs.

Rs.

Rs.

Rs.

2943.50

1321.20

3004.20

1417.90

3031.50

1345.60

3140.00

1454.00

bZV jfgr

izfr ?ku ehVj


05085 lhoj bZVksa ls lek;kstu ij 6
eh ls vf/kd vkSlr f=T;k dh
lh/kh ;k o fpukbZ lhoj dke
esa esugksy lsfIVd Vsd
a lksdosy
vkfn gsrq
05086 mi;qDZ r] o dk;Z esa lek;kstu
ij 6 eh ls vuf/kd vkSlr f=T;k
dh

MATERIALS (Supplied only)


lkexzh dsoy vkiwfrZ
PER 1000 NOS.

izfr 1000 ua-

Old size bricks Modular bricks

iqjkus uki dh bZV


05087 Bricks; common burnt clay
building bricks, sub-class A

designation 75
05088 Ditto sub-class B Designation

75
05089 Brick tiles; common burnt clay
building bricks sub-class A

Desig- nation 75

05090 Ditto sub-class B Designation 75

ekMqyj bZV

Rs.

Rs.

2702.50

2526.20

2526.20

2350.00

2526.20

2350.00

2350.00

2232.50

05091 Purpose moulded bricks such as


bullnosed, splayed, weathered

and throated, etc.


05092 Burnt clay fly ash building bricks

designation 75(Kg/cm2)

2673.10

2790.60

2702.50

2526.20

05093 Ditto bricks tiles ditto

2538.00

2352.30

PER 100 NOS.

05087 bZVsa] fpduh feh dh idh gqbZ vke


bekjrh bZVksa] miJs.kh *,* inuke
75
05088 mi;ZqDr] miJs.kh *ch* inuke 75
05089 bZV Vkbys(a fpduh feh dh idh gqbZ vke
bekjrh bZV miJs.kh *,* inuke 75
05090 mi;ZqDr] miJs.kh *ch* inuke 75
05091 iz;kstu x<+h bZVsa tSls] dqCck] piVh]
rqlg] o daBh vkfn
05092 nX/k fpduh feh mMu jk[k ls cuh
bekjrh bZ V s inuke 75
fdxzk@?keh2
05093 mi;qZDr bZV Vkbys mi;qZDr
izfr 100 u-

Rs..
2232.50

05094 vfXulg bZV vkdkj 230 x 113 x 75 feeh

2467.50

05095 mi;qZDr] iz;kstu x<+h

05096 Facing bricks,class II, old size bricks

235.00

3525.00

05096 eksgjk bZVsa oxZ II iqjkus vkdkj dh bZVsa


05097 mi;qZDr] ekMqyj bZVsa
05098 vEy jks/kh bZVsa vkdkj 230 x 14 x 64 fe eh Js.khA

397.60

05099 lhoj bZVsa

05094 Fire bricks, size 230 x113 x 75 mm


05095 Ditto purpose moulded
05097 Ditto modular bricks

05098 Acid resisting bricks, size 230 x 114 x

64 mm, class I
05099 Sewer bricks

75

SECTION 5

SECTION 5BRICK WORK


[k.M 5 bZV dk dk;Z
MATERIALS (Supplied only) Contd...
lkexzh dsoy vkiwfrZ & tkjh--Rs.

PER KILOGRAM

izfr fdyksxzke
05100 jk[k elkyk
05101 jklk;fud jks/kh elkyk] jsflu fdLe dk

05100 Fire clay mortar

05101 Chemical resistant mortar, resin

type

05102 Ditto sulphur type

47.00
41.10

05102 mi;ZqDr] lYQj fdLe dk

05103 Glass, broken to 63 mm gauge

11.70

05103 VwVk dkp 63 feeh izekih dk

7.00

izfr ?ku ehVj

PER CUBIC METRE


05104 Sand for masonry mortars

558.10

05104 ckyw fpukbZ elkys ds fy;s

76

SECTION 6

SECTION 6 STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
SPECIAL CONDITIONS
fo'ks"k krsZ
6.1

Measurements

6.1.1 Stone Walling:


(a) Battered, tapered and curved walls shall be
measured net.
(b) No deductions or additions shall be made on
any account for:
(1) Ends of dissimilar materials (i.e. joists,
beams, lintels, posts, girders, rafters,
purlins, trusses, corbels, steps, etc.), upto
0.1 sq. m in section.
(2) Opening upto 0.1 sq. m in area.
(3) Wall and bed plates, bearing of slabs,
chajjas and the like, where the thickness
does not exceed 10cm and the bearing does
not extend over the full thickness of the wall.
(4) Cement concrete blocks for holdfasts,
holding down bolts and the like.
(5) Iron fixtures such as wall ties, pipes upto
300 mm dia and holdfasts of doors,
windows, etc.
(6) Chases of section not exceeding 50 cm in girth.

6-1 eki
6-1-1 iRFkj dh nhokj cukuk
d <+yoka] kq.Mkdkj rFkk o nhokjsa fokq) ekih tk;saxhA
[k fuEu ij fdlh Hkh dkj.k ls u dVkSrh gksxh vkSj u gh
vfrfjDr fn;k tk;sxkA
1 vleku phtksa tSls] dfM+;ksa] /kjuksa] fyaVy] [kaHks]
kgrhj] vk/kkj dM+h] iyhZu] dSfa p;ks]a VksMks]a lhf<+;ka
vkfn ds 0-1 oxZ eh rd dkV ds NksjA
2 0-1 oxZ eh Js= ds fooj [kkyh LFkkuA
3 nhokj o vk/kkj jn~nk] ifV;k /kkjd] NTts rFkk ,sls
gh vU; ftudh eksVkbZ 10 lseh ls vf/kd ugha gS
rFkk /kkj.k] nhokj dh iwjh eksVkbZ ls vf/kd ugha gSA
4 idM+ iV~Vh] dkoys rFkk ,sls vU; ds fy;s lhesaV
dahV ds <+kpsA
5 yksgs ds lkt lkeku tSls nhokj [kwafV;k 300 feeh
rd ds uy o njokts f[kM+fd;ksa dh idM+ ihA
6 dkV ds [kkaPks ftudk ?ksjk 50 lseh ls vf/kd u gksA

Note In calculating area of an opening, any separate


lintel or cill shall be included with the size of
opening but not the extra width of rebated
reveals, if any, and end portion of the lintels.

uks V % fdlh fooj ds {ks=Qy dk fglkc yxkrs le; fdlh vyx


fyaVy ;k fly ds vkdkj dks fooj ds lkFk feyk fn;k
tk;sxk fdUrq iSuke ;k ik[kksa dh vfrfjDr pkSMk+ bZ ;fn dksbZ
gks o fyaVy ds Nksj ds Hkkx dks ugha tksMa k+ tk;sxkA
(c) Deductions for opening exceeding 0.1 sq. m shall
x 0-1 oeh ds fooj dh dVkSrh djus ds fy;s fooj ds
be measured to the minimum size of the opening.
U;wure vkdkj dks ekik tk;sxkA

(d) Stone walling (excluding fire brickwork) in


chimney breasts, and chimney stacks with
smoke or air flues n exc 0.20sq m sectional area
shall be measured as solid and no extra
payment shall be made for pargetting and coring
such flues. Where the flues exceed 0.2 sqm
sectional area, deduction for the same shall be
made from stone walling and pargetting and
coring measured under Section 14 Plastering
and Pointing. Apertures for fire places shall
not be deducted and extra labour shall not be
measured for splaying of jambs and throating.
6.1.2 Dressed Stone:
(a) In measuring cubic contents of dressed stone
work the contents of the smallest rectangular
dressed block from which the finished dressed
stone can be worked shall be taken. Only
specified dimensions shall be allowed.

?k fpeuh ds vxzHkkx o ?ksjs esa iRFkj dh nhokj vfXulg


bVksa dks NksMd
+ j dh eki 0-20 oeh ls vuf/kd dkV {ks=
ds /kq;as ;k gok ds fNnz lfgr Bksl yh tk;sxh rFkk ,sls
LFkkuksa ds iyLrj o fyikbZ ds fy;s vfrfjDr Hkqxrku
ugha fd;k tk;sxkA tgka ;g /kqvkadk 0-2 o eh dkV {ks=
ls vf/kd gksa ogk budh dVkSrh nhokj esa ls dh tk;sxh
rFkk iyLrj o fyikbZ dh eki [kaM 14& iyLrj o Vhi
dk;Z ds vUrxZr dh tk;sxh vaxhBh ds vkdkj lqjk[k
dh dVkSrh ugha gksxh rFkk mlds ik[ks o ijh Hkkx dks
cukus ds fy;s vfrfjDr Je dh eki ughas gksxhA
6-1-2 rjkkk gqvk iRFkj
d rjkks gq, iRFkj dk ?ku ifjek.k ekius ds fy;s ml U;wure
vk;rkdkj ifV;k dk ifjek.k fy;k tk;sxk ftlesa ls og
iRFkj rjkkk tk ldrk gSA dsoy fufpr ifjeki gh ekU;
gksxkA

77

SECTION 6

SECTION 6 STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
SPECIAL CONDITIONS Contd..
fo'ks"k krsZ& tkjh
tkjh..
(b) In measuring labour only on stone, all work
[k **iRFkj dk;Z ij dsoy Je** dh eki djus ds fy;s lHkh 10
exceeding 10cm in width (or girth) shall be paid
lseh pkSMk+ bZ ;k eksVkbZ ls vf/kd ds dk;ksZ dks oxZ eh- esa
for in sq. m and work n exc 10cm in width (or
ekik tk;sxk rFkk 10 lseh vuf/kd pkSMk+ bZ ;k eksVkbZ ds
girth) in running metres. Internal and external
dk;ksZ dks ehVj essa vUnj ckgj ds dksfu;k dks.k] rFkk x<+r]
mitred angles and stops to mouldings,
i[k vkfn ds tksM+ ds fy, izR;sd dk HkqxRkku gksxkk ;fn
chamfers, etc., shall each be paid for, if the work
is measured superficially, as one-third of a
eki lrgh yh xbZ rks ,d ehVj ds ,d frgkbZ dks x<+r
running metre multiplied by the girth of the
dh eksVkbZ ls xq.kk djds rFkk ;fn dk;Z dks ijEijkxr <ax
moulding, etc., and as one-third of a running
ls ekik x;k gS rks ,d ehVj dk frgkbZ ns; gksxkA

metre, if the work is measured lineally.


(c) In measuring labour on stone, plain work, sunk
work, moulded work, etc., as seen on the finished
faces, shall be measured without any allowance
for preliminary labour of any description.
(d) The following descriptions apply to the terms
used in connection with dressed stone and
labour thereon:Straight work- All stones worked and bedded
to a true straight line, whether moulded on face
or not.
Circular workAll Stones dressed and
bedded circular on plan or elevation.
Circular circular workStone dressed and
bedded both circular on plan and circular in
height or depth as in domes, etc.
6.2 Rates
6.2.1 The rates for stone walling include for :
(a) All scaffolding, ladders, plant and templets
required in the execution of work;
(b) Extra labour in beam filling (measured solid
without deduction for rafters, etc.);
(c) Rough cutting and waste for forming gables,
cores of arches, splays at eaves and the like
and all rough cutting in the body of the walling;
(d) Raking out joints for plastering or for pointing
or finishing the joints flush as the work
proceeds, where specified;
(e) Bedding and pointing wall plates, lintels, cills,
roof tiles and corrugated sheets etc., in or on
walls solidly in mortar as for adjacent work
and making good;
(f) Building in or cutting and pinning ends of
joists, beams, etc., in mortar as for adjacent work
and making good;
(g) Making or leaving holes for fixing, pipes, bolts,
etc. and weep-holes. and making good;
(h) Forming chases (or cutting instead at the option
of the contractor where approved by the EIC) in
new work for edges of concrete floors;

x **iRFkj dk;Z ij Je** ekius ds fy;s] lknk dk;Z] ikuh esa dk;Z]
x<+kbZ dk;Z vkfn tSls iwfjr lrg ij fn[kkbZ nsrs gS] fcuk
izkjfEHkd dk;Z ds Je dk vfrfjDr yxk;s] ekik tk;sxkA
?k rjkks x;s iRFkj rFkk mlds Je ds lacU/k esa iz;qDr
kCnksa dk fuEu fooj.k ykxw gksxk%&

**lh/kk dk;Z** iRFkj dh lHkh okLrfod lh/kh fpukbZ rFkk


fcNkbZ dk;Z pkgs vkxs ls x<+k gks ;k u gksA
**xksydkj dk;Z** iRFkj rjkkuk rFkk la;kstu ;k mPp
dks.k ij xksykdkj fcBkukA
**xksy pkdkj dk;Z** iRFkj rjkkuk rFkk la;kstu rFkk apkbZ
;k xgjkbZ nksuksa izdkj ls xqEen vkfn dh rjg fcBkukA
6-2 njsa
6-2-1 iRFkj fpukbZ esa fuEu dk;Z kkfey gS%&
d dk;Z fu"iknu esa vko;d] ikM cka/kus dk lkeku lhf<+;ka]
la;a= o vk/kkjA
[k /kju che HkjkbZ ds fy;s vfrfjDr Jfed dM+h vkfn
dh dVkSrh ds fcuk Bksl eki gksxhA
x uksd i[k esgjkoksa ds Hkhrjh Hkkx vksyrh ds <ky cukus
rFkk vU; ,sls dk;ksZ ds fy;s lknh dVkbZ o Nhtu rFkk
dk;Z dh jpuk esa lHkh lknh dVkbZA
?k iyLrj ;k Vhi dk;Z ds fy;s tksM+ksa dks [kqjpuk ;k
tSl&
s tSls dk;Z vkxs c<+rk gS] tgka fufnZV gks tksMk+ as dks
ikuh ls lkQ djukA
M nhokj if;ksa] fyaVy] fly] Nr Vkbyksa o iukjhnkj
pn~njksa vkfn dks nhokj esa ;k ij lkFk ds dk;Z leku
elkys ls yxkuk o ifjr djukA
p dM+h o /kju ds Nksj cukuk ;k dkVuk o lkFk okys dk;Z
ds elkys ls tksM+uk o ifjr djukA
N uy] dkoys vkfn rFkk fjlkoh Nsn cukuk ;k NksM+ nsuk
rFkk ifjr djukA
t u;s dk;Z esa dahV QkkZas ds fdukjksa ds fy;s [kkaps cukuk
;k Bsdns kj ds foosd ij izHkkjh vfHk;ark dh Lohfr ls
cukus ds LFkku ij dkVuk

78

SECTION 6

SECTION 6 STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
SPECIAL CONDITIONS Contd.
foks"k krsZ& tkjh
tkjh..
(j) Forming or leaving chases (or cutting instead
at the option of the contractor where approved
by the EIC) for concealed water tubing and
concealed conduit wiring;
(k) Building in holdfast, air bricks, fixing bricks,
grates, soot doors, cast iron boxes, etc., and
making good;
(l) Pargetting and coring with cowdung and lime
mortar, flues upto 0.20 sq.m. sectional area;
(m) Forest copings (superior copings) to be paid
under the items for dressed stone work;
(n) Preparing tops of existing walls and the like
for raising;
(o) Levelling up and preparing tops of walls for
damp proof courses, band courses and the like
and levelling rivetted tops of girders, etc.;
(p) Forming openings and flues for which no
deduction is to be made;
(q) Plumbing to angles;
(r) Forming reveals to jambs where fair cutting on
exposed faces is not involved;
(s) Building in vertical seismic reinforcement at
the jambs of openings, corners of walls, etc.,
including grouting in cement mortar 1:4.
(t) Keeping stone masonry well wetted during the
curing period.
6.2.2 The rates for stone walling apply to the following :-

> ncs ikuh uy o fctyh ds rkj dh ukfy;ksa ds fy;s Nsn


cukuk ;k NksM+uk ;k Bsdsnkj ds foosd ij izHkkjh
vfHk;ark dh Lohfr ls cukus ds LFkku ij dkVuk
+= idM+ ih] fNfnzr bZV] eksgjk bZV] tkyh] dTty njokts]
<ys yksgs ds cDls vkfn esa Nsn cukuk rFkk ifjr djukA
V 0-20 o eh rd ds dkV {ks= ds /kqv
a k ekxZ ij pwuk elkys
o xkscj ls iyLrj o fyikbZ djukA
B cu eqaMsjs cf<+;k eaMsjs dk Hkqxrku rjkks x;s iRFkj ds
dk;Z dh njksa esa gksxkA
M fo|eku nhokjksa o vU; lkeku dksp
+a k djus ds fy;s 'kh"kZ
rS;kj djukA
< lhyu jks/kh jn~nk] vk/kkj Lrj rFkk leku ds fy;s nhokj
ds khkZ dks lery djds rS;kj djuk rFkk xkMZj vkfn
dh QVh ijh lrg dks le djukA
.k fooj o fpeuh Nsn cukuk ftldh dksbZ dVkSrh ugha
gksuh gSA
r NM+ksa dh dVkbZ
Fk ik[ks ds ckgjh Hkkx cukuk tgka lEeq[k lrg ij eghu
dVkbZ kkfey ugha gSaA
n foojksa ds ik[kksa nhokj ds dksuksa vkfn esa 1%4 ds lhesaV
elkys dh HkjkbZ lfgr [kM+h HkwdEih izoyu cukukA

/k iDdh gksus rd ds le; lalk/ku dky esa iRFkj dh


fpukbZ dks vPNh rjg rj j[kukA
6-2-2 iRFkj fpukbZ dh njsa fuEufyf[kr ij ykxw gksrh gS%&
(a) Walls built either perpendicular, battered or tad iz;kstu ij 6 eh ls vf/kd dh pkgs yfEcr] <yoka ;k
pered, straight or curved on plan to a mean
kqMkdkj] lh/kh ;k o cuh nhokjsa ry vk/kkj] vkSyrh o
radius exc 6m including footings, eaves and
/kju dh HkjkbZ o iyLrj dk;Z lfgrA
beam filling and pillasters.

(b) Pillars, buttresses, etc., square or rectangular


on plan.
NoteRectangular pillar/columns shall mean a
detached masonry portion such that its
breadth does not exceed 3 times its thickness
and thickness itself does not exceed 60cm.
(c) Chimney breasts and chimney stacks, smoke
and air flues; single flues or group of flues
carried above roof (and not independent
chimney shafts as for factories). Fire brick work
will be measured separately.
(d) Bridges, culverts, cesspools, etc.
6.2.3 Type of Stones:- Rates for stone masonry and labour
thereon have been given broadly for two categories
of stones; granite and trap (harder stones) and lime
stone and sand stone (ordinary varieties). Other
types of stones where specified to be used, unless
specifically referred to, shall be categorised into
harder or ordinary varieties and indicated.

[k [kaHks] iqrs vkfn la;kstu ij pkSdksj ;k vk;rkdkjA


uksV% vk;rkdkj LrEHkks@
a [kaEHkksa dk vFkZ gksxk vlaxr fpukbZ
[kaM ftldh pkSMk+ bZ bldh eksVkbZ ds rhu xq.ks ls
vf/kd u gks rFkk Lo;a eksVkbZ 60 lseh ls vf/kd u gksA
x fpeuh dk e/; o ij dk Hkkx ?kqa;s ;k ok;q fNnz Nr
ds ij rd ys tk;s x;s ,dy ;k lewg fNnz oSls
fpeuh kSV ugha tSls dkj[kkuksa ds fy;s gksrs gS vfXu
lg bZV dk;Z izFkd ekik tk;sxkA
?k iqy] iqfy;k] eydwi vkfnA
6-2-3 iRFkjksa ds izdkj% iRFkjksa dh fpukbZ o Je dh bu njksa esa
eksVs rkSj ij nks izdkj ds iRFkj fn;s x;s gSa( xzsukbV o VSi
pV~Vkuh o l[r iRFkj rFkk pwuk iRFkj] Ckyqvk iRFkj
lkEkkU; fdLe tgkW vU; Ikzdkj ds IkRFkj iz;ksx esa ykus dk
fufnZV gks tc rd fd foksk:i ls lnfeZr u gks rks dBksj ;k
lkekU; dk oxZHksn gksxk o nkkZ;k tk;sxkA

79

SECTION 6

SECTION 6 STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
SPECIAL CONDITIONS Contd..
foks"k krsZ& tkjh
tkjh..
6.2.3.1 Where the type of stone is not mentioned, the rates
are applicable for any kind of stone.
6.2.4
Laterite Stone:- When locally found laterite stone
is ordered. 33 1/3% or 33.33% deduction shall be
made from the rates for walling. Facing shall be
paid at the rates for lime stone/sand stone.
6.2.5

6.2.6

6.2.7

For the work carried out at YOL, the rates for


materials and labour against SSR items 06001,
06002 and 06004 are for work using best local
stone, (excluding best local slate stone). For work
carried out with best local slate stone the rates for
materials and labour against SSR items 06001,
06002 and 06004 shall be decreased by 5 per cent
of the difference between materials and labour
rates and corresponding except stone rates.
Facing shall be paid at the rates for lime stone/
sand stone.
Except Stone:- The rates for except stone, in
addition to labour for setting and cost of
subsidiary materials, include all labour for
dressing the stones to the required size and shape.
Bond Stones:- If PCC bond stones are indicated in
lieu of stone bond stones, adjustment shall be
made as under:
(a) The volume occupied by PCC bond stone
shall be measured and deduction made for
this quantity priced at thrice the difference
between the materials and labour rates for
walling and except stone rates.
(b) Payment for PCC bond stones shall be made
under appropriate item of SSR.

6-2-3-1 tgka iRFkj dh fdLe ugha crkbZ xbZ gS rks njsa fdlh Hkh
fdLe ds iRFkj ij ykxw gksaxhA
6-2-4 ysVfjV iRFkj% tc mlh LFkku ij ik;s tkus okys ysVfjV
iRFkj dk vknsk gksrk gS rks nhokj dk;Z esa ls 331/3% dh
dVkSrh dh tk;sxh iz"B QSflax dk Hkqxrku pwuk
iRFkj@cyqvk iRFkj dh njksa ij gksxkA
6-2-5 ;ksy esa fd;s x;s dk;Z ds fy, lkexzh o Je dh ,l ,l
vkj dh en 06001] 06002 o 06004 dh njsa LFkkuh; mke
iRFkj mke LysV iRFkj dks NksMd
+ j ds iz;ksx ds fy;s gSAa
LFkkuh; LysV iRFkj ds fy;s en 06001] 06002 o 06004
esa ls] **lkexzh o Je** rFkk lekukUrj **iRFkj jfgr** dh
njksa ds chp ds vUrj dk] 5% ?kVk fn;k tk;sxkA izB dk
Hkqxrku pwuk iRFkj@cyqvk iRFkj dh njksa ij gksxkA
6-2-6

iRFkj jfgr% **iRFkj jfgr** dh njksa esa] LFkkiu ds Je o


lgk;d lkexzh ds ewY; ds vykok] iRFkjksa dks visf{kr uki
o vkdkj esa rjkkus dk lHkh Je kkfey gSA

6-2-7

;fn iRFkj dks iRFkj ls tksM+us ds ctk; ih lh lh esa


iRFkj tksM+uk nkkZ;k tkrk gS rks mldk lek;kstu bl
izdkj gksxk%
ih lh lh esa ca/ks iRFkj dk;Z dk ifjeki ekik t;sxk rFkk
**lkexzh o Je** rFkk **iRFkj jfgr** dh njksa ds vUrj dk
frxquk ml dke dh nj essa ls ?kVk;k tk;sxkA

[k

ih lh lh esa ca/ks iRFkjksa dk Hkqxrku ,l ,l vkj dh


mi;qZDr njksa ds vUrxZr fd;k tk;sxkA

80

SECTION 6

SECTION 6 STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
STONE WALLING
iRFkjksa ls nhokj cukuk
(a) The rates for items 06001 to 06033 do not apply to stone
walling, Jodhpur type.
(b) Rates for items 06002 to 06005 shall also be applicable to
squared rubble masonry, regular coursed Secunderabad
and Bangalore types and to slate stone masonry at YOL.

d en 06001 ls 06033 dh njs]a tks/kiqjh IkRFkj dh nhokj ij ykxw ugha gksrh gSA

06001Walling of random rubble,


uncoursed, well bonded, laid dry
in retaining walls, abutments and

similar work

lkezzxh o Je

iRFkj jfgr

Rs.

Rs.

927.80

327.80

[k en 06002 ls 06005 dh njsa] pkSdksj vux<+ iRFkjksa dh fpukbZ]


fu;fer rjkks fldUnjkoknh o caxykSjh fdLe ds iRFkjksa rFkk
;ksy esa LysVh iRFkjksa dh fpukbZ ij Hkh ykxw gksaxhA
(c) Facework shall be measured separately and paid under items x izB ckgjh dk;Z izFkd ekik tk;sxk rFkk mldk Hkqxrku en
06025 to 06033.
06025 ls 06033 ds vUrxZr gksxkA
(d) External angles in facing shall be measured under items ?k izB Hkkx ds ckgjh dks.k en 06042 ls 06048 ds vUrxZr ekis
06042 to 06048.
tk;saxsA
PER CUBIC METRE
izfr ?ku ehVj
M&L
Except stone
06001 /kkjd nhokjks]a vR;k/kkjksa o leku dk;ksZ es]a
vleku] vux<+ iRFkjksa dks vuLrjh; pky
esa iw.kZr% vko djrs gq;s lw[kk yxkuk
izfr ?ku ehVj

PER CUBIC METRE


Mud mortar

Lime mortar

feh elkyk

pwuk elkyk

06002Walling of random rubble,


uncoursed, well bonded, bedded

and solidly hearted, built in


06003Ditto, but except stone

06004Walling
of
random rubble,
uncoursed as
in item 06002,

built in
06005Ditto, but except

stone

06006Walling of polygonal rubble,


uncoursed well
bonded, bedded
solidly hearted,

built in
06007Ditto but except

stone

1:4
Rs.

1:3
Rs.

1:2
Rs.

06002 vuLrjh; pky es]sa vleku] vux<+


iRFkjksa dks] iw.kZr% vko) djrs gq;s bl

elkys dh Bksl HkjkbZ ls fcBkuk


1669.30 1645.87 1733.40
969.70 1000.80 1031.90 06003 mi;qZDr] fdUrq iRFkj jfgr

Rs.

Cement lime mortar

Cement mortar

lhesaV pwuk elkyk

lhaesV elkyk

1:2:9

1:1:8

1:1:6

1:8

1:6

1:4

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

1564.60

1530.40

1564.60

1797.20

1898.90

2106.70

863.10

828.90

862.30

1097.70

1197.50

1405.20

Mud mortar

Lime mortar

feh elkyk
Rs.

pwuk elkyk
1:4

1:3

1:2

Rs.

Rs.

Rs.

1706.90

1738.00

1769.10

1005.40

1036.50

1067.60

06004 vleku] vux<+


dh vuLrjh;
pky esa en 06002
tS l h nhokj]
bl elkys esa
06005 mi;q Z D r] fdUrq
iRFkj jfgr
06006 cgqdks.kh;] vux<+
iRFkjksa dh vuLrjh;
pky esa iw.kZr% vkc)
djrs gq;s fcBkuk
rFkk bl elkys esa
Bksl HkjkbZ djuk
06007 mi;q Z D r] fdUrq
iRFkj jfgr

81

SECTION 6

SECTION 6STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
STONE WALLING Contd..
iRFkjksa ls nhokj cukuk tkjh
tkjh..

izfr ?ku ehVj

PER CUBIC METRE


Cement lime mortar
06008 Walling
of lhesaV pwuk elkyk
polygonal rubble,
1:2:9
1:1:8
1:1:6
uncoursed as in
Rs.
Rs.
Rs.
item 06006, built 1596.59 1562.40
1596.60

in
06009 Ditto, but except 895.10
859.70
895.10

stone

06010Add to items 06002 to 06009


for random or polygonal
rubble walling curved on plan
to a mean radius n exc 6 m

Cement mortar

lhaesV elkyk
1:8
Rs.
1820.60

1:6
Rs.
1920.40

1:4
Rs.
218.10

1119.20

1218.90

1426.60

M&L

Except stone

lkezzxh o Je

iRFkj jfgr

R.s.

Rs.

137.50

52.90

55.50

55.50

06011Extra over items 06001 to 06009


for random or polygonal rubble

walling, brought up to course

06008 cgqdks.kh;] vux<+


iRFkjks a
dh
vuLrjh; pky esa
en 06006 tSlh
nhokj cukuk
06009 mi;qZDr] fdUrq
iRFkj jfgr

06010 vleku ;k cgqdks.kh; vux<+ iRFkjksa


dh iz;kstu ij vkSlru 6 eh vuf/kd
dh o nhokj ds fy, en 06002 ls
06009 esa tksM+as
060
11 vleku ;k vux<+ cgqdks.kh; iRFkj
06011
dh nhokj dks Lrj rd ykus ds y;s
fen 06001 ls 06009 ij vfrfjDr

Lime mortar

pwuk elkyk
06012Walling of squared
rubble, uncoursed, well
bonded, bedded and

solidly hearted, built in

1:4
Rs.

1:3
Rs.

1:2
Rs.

1639.80

1781.20

1812.30

06013Ditto, but except stone

1098.60

1129.70

1160.80

06014Walling of squared
rubble, uncoursed
as in item 06012,

built in

06015Ditto, but except

stone

Cement lime mortar

06014 pkSdksj vux<+ iRFkjksa


dh vuLrfjr pky
1:6
1:4
esa en 06012 tSlh
Rs.
Rs.
bl elkys esa nhokj
1976.40 2184.20
cukuk
06015
mi;qZDr] fdUrq
1324.90 1532.70
iRFkj jfgr

Cement mortar

lhesaV pwuk elkyk

lhaesV elkyk

1:2:9
Rs.
1639.80

1:1:8
Rs.
1605.70

1:1:6
Rs.
1639.80

1:8
Rs.
1876.70

988.30

954.10

988.30

1225.20

06016Extra over items 06012 to


06015 for squared rubble
walling brought up to courses

06012 pkSdksj vux<+ iRFkjksa dks vuLrjh;


pky esa iw.kZr% vko) djrs gq;s bl
elkys ls Bksl HkjkbZ djds fcBkrs
gq;s nhokj cukuk
06013 mi;qZDr] fdUrq iRFkj jfgr

M&L

Except stone

lkezzxh o Je

iRFkj jfgr

R.s.

Rs.

90.80

55.50

06016 pkSdksj vux<+ iRFkjksa dh nhokjksa dks


Lrj rd ykus ds fy;s en 06012
ls 06015 ij vfrfjDr

82

SECTION 6

SECTION 6STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
STONE WALLING Contd..
iRFkjksa ls nhokj cukuk tkjh
tkjh..
izfr ?ku ehVj

PER CUBIC METRE


06017Walling
of Lime mortar
squared rubble, pwuk elkyk
regular coursed,
1:3
1:2
well bonded,
Rs.
Rs.
bedded
and
solidly hearted,
1900.80 1931.90
built in
06018Ditto, but except
1296.70 1225.40
stone

Cement lime Mortor

Cement mortar

lhaesV pwuk elkyk

lhaeVs elkyk

1:1:8
Rs.

1:1:6
Rs.

1:6
Rs.

1:4
Rs.

1725.20

1759.40

2071.00

2278.80

1018.80

1052.90

1364.50

1572.30

2075.10

1868.40

1902.60

2221.10

2428.80

1420.00

1213.30

1247.50

1566.00

1773.80

06021Ashlar masonry,
plain,
well
bonded, built in 2571.60

2602.60

2396.00

2430.20

2748.60

2955.80

06022Ditto, but except


1811.90
stone

1843.00

1636.30

1670.50

1988.50

2196.20

06019Block-in-course
masonry well
2044.00
bonded, built in
06020Ditto, but except
1388.90
stone

06017 pkS d ks j vux<+


fu;fer Lrj ij
iRFkjksa dks iw.kZr% vkc
djrs gq;s bl elkys
ls fcBkuk o Bksl
HkjkbZ djuk
06018 mi;q Z D r] fdUrq
iRFkj jfgr
06019 iw . kZ r % vkc bl
elkys esa nko jn~nk
fpukbZ djuk
06020 mi;q Z D r] fdUrq
iRFkj jfgr
06021 iw.kZr% vkc lrg
ij bl elkys esa
fvLyj pukbZ
06022 mi;q Z D r] fdUrq
iRFkj jfgr
izfr ?ku ehVj

PER CUBIC METRE


06023Add to items 06012 to 06015 and
06017, 06018 for squared rubble
walling, uncoursed, brought to
courses or regular coursed;
curved on plan to a mean radius

not exceeding 6 m

M&L

Except stone

lkezzxh o Je

iRFkj jfgr

Rs.

Rs.

131.30

60.80

06024 Add to items 06019 to 06022. for


block- in-course and ashlar
masonry curved on plan to a mean
radius not exceeding 6 m

06023 pkSdksj vux<+ fpukbZ] vuLrfjr] dks


Lrj rd ;k fu;fer Lrj rd ykus]
vk;kstu ij vkSlru 6 eh ls vuf/kd o
nhokj ds fy;s en 06012 ls 06015 o
06017] 06018 esa tksMs+a
06024 nko jn~nk rFkk vLyj fpukbZ vk;kstu
ij vkSlru 6 eh vuf/kd o ds fy;s en
06019 ls 06022 esa tksMas+

FACING TO STONE WALLING


iRFkj dh nhokj dk eksgjk Qsflax cukuk
(a) Each finished face shall be measured.
(b) 50 per cent extra shall be allowed for facework to walls built to
curve n. exc. 6m mean radius. This allowance includes for all
cutting and waste, templates etc.
(c) 25 per cent extra shall be allowed for facework to battered
or tapered walls.
(d) If at places, finish superior to general facework is indicated,
the difference in rate between the two finishes shall be
allowed for such portions

d izR;sd laiwfjr eksgjk ekik tk;sxkA


[k eksgjs dh vkSlru 6 eh vuf/kd ij o cuh nhokj ij 50
izfrkr vfrfjDr Lohd`r fd;k tk;sxkA ;g Hkkk lHkh izdkj dh
dVkbZ o Nhtu] [kkaps vkfn kkfey djrk gSA
x vkUrfjd <yoka ;k kq.Mkdkj nhokjksa ij eksgjk dk;Z ds fy, 25
izfrkr vfrfjDr fn;k tk;sxkA
?k ;fn eksgjs Hkkx ij lkekU; izB dk;Z ds LFkku ij cf<+;k
ifjd`fr djus dks dgk tkrk gS rks nksuksa ifjd`fr;ksa ds chp ds
vUrj dk Hkqxrku gksxkA

83

SECTION 6

SECTION 6 STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
FACING TO STONE WALLING Contd..
iRFkj dh nhokj dk eksgjk Qsflax cukuk& tkjh
tkjh..
PER SQUARE METRE

Hammer dressing with maximum depression on


face from straight edge held against the dressed
surface n exc.

06025Extra over stone walling


for hammer dressing to izB ij vf/kdre ncko ls ?kqjeqV ls dqVkbZ izlkf/kr lrg
face stones and dressing
ls blls vuf/kd j[kuk
of face beds and joints, Lime or sand stone
Granite or Trap stone
as specified, of random pwuk ;k cyqvk iRFkj
xzsukbV ;k ca/kqvk iRFkj
rubble
walling, 40mm
20mm
40mm
20mm
uncoursed or brought
Rs.
Rs.
Rs.
Rs.

upto courses
58.20
89.90
116.30
169.20
06026Ditto, of polygonal
rubble
walling,
uncoursed or brought

upto courses
63.40
97.80
126.90
195.60
06027Ditto, of squared
rubble walling, regular
coursed, Secunderabad
and Bangalore types
142.80
285.50
06028Ditto, of squared
rubble
walling,
uncoursed
and

brought upto courses


06029Ditto, of squared
rubble masonry, regular

coursed
06030Ditto,
of block-in
course masonry
06031Ditto, of ashlar masonry

243.20

272.30

486.40

544.60

290.80

581.60

594.80
555.20

1189.70
1110.40

izfr oxZ ehVj


06025 vfrfjDr vleku] vux<+ iRFkjksa
dh vuLrjh ;k Lrj pky rd
vkbZ nhokj ds iRFkjksa dh ?kqjeqV
ls dqVkbZ djus rFkk fufnZVkuqlkj
eksgjs ds vk/kkj o tksMk+ as dks
izlkf/kr djus ij
06026 mi;qDZ r] fdUrq cgqdks.kh;] vux<+
iRFkjksa dh vuvLrfjr ;k Lrj
pky rd ykbZ xbZ nhokj
06027 mi;qDZ r] fdUrq pkSdksj vux<+
fldUnjkoknh ;k caxykSjh fdLe
ds iRFkjksa dh fu;fer Lrjh;
pky dh nhokj
06028 mi;qDZ r] fdUrq pkSdksj vux<+
iRFkjksa dh vuvLrfjr pky rFkk
Lrj rd ykbZ xbZ nhokj
06029 mi;qDZ r] pkSdksj vux<+] iRFkjksa
dh fu;fer Lrjh; fpukbZ
06030 mi;qDZ r] Lrj esa [kaMd dh fpukbZ
06031 mi;qZDr] vLyj dh fpukbZ

For facework finished as under

bl izdkj ds ifjd`r izB dk;Z ds fy;s

PER SQUARE METRE

Lime or sand stone


06032Extra over hammer
dressed facings,
with maximum
depression on face
from straight edge
held against the
dressed surface n.
exc 20 mm; to
block-in-course
masonry

izfr oxZ ehVj

Granite or Trap stone

06032 vfrfjDr] Lrj esa


[kaMd dh fpukbZ
Rock Punched Close Fine
Rock
PunClose Fine
faced dressed picked tooled faced
ched picked tooled
ij eksgjs ls 20
face
dressed dressed
dressed dressed dressed
feeh vuf/kd
face
face
face
face
face
fdukjs j[krs gq,
pouh Vkafpr xgu
cf<+;k
pouh
Vkafpr xgu
cf<+;k
lrg
ij
eksgjk ifjd`r dqVk
vkStkjh eksgjk
ifjd`r dqVk
vkStkjh
eksgjk
izlkf/kd izlkf/kd
eksgjk izlkf/kd izlkf/kd
vf/kdre ncko ds
eksgjk eksgjk
eksgjk eksgjk
lkFk dqVkbZ djds
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
eksgjk izlkf/kr
264.40 317.20 356.90 396.60 528.70 634.50 713.80 793.10
djus ij

pwuk ;k cyqvk iRFkj

06033Ditto, to ashlar
211.50 264.40
masonry

290.80 343.70

xzsukbV ;k ca/kqvk iRFkj

423.00

528.70 581.60 687.40

06033 mi;qDZ r] vLyj


fpukbZ ij

84

SECTION 6

SECTION 6STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
STONE WALLING, JODHPUR TYPE
tks/kiqj fdLe ds iRFkj dh nhokj cukuk
(a) Facework shall be measured separately under items 06040
and 06041.
(b) External angles in facings shall be measured separately
under items 06042 to 06048.
PER CUBIC METRE
06034Squared rubble walling, Jodhpur
type, laid dry, brought to course

and well bonded

M&L

[k eksgjs ds ckgjh dks.k dks izFkd en 06042 ls 06048 ds vUrxZr


ekik tk;sxkA
izfr ?ku ehVj
Except stone

lkexzh o Je

iRFkj jfgr

R.s.

Rs.

845.90

365.30

Lime mortar

06035 Squared
rubble
walling, Jodhpur
type brought upto
courses, well bonded,
bedded and solidly
hearted, built in
06036 Ditto, but except stone
06037 Squared
rubble
walling Jodhpur type,
regular coursed, well
bonded, bedded and
solidly hearted, built

in
06038 Ditto, but except stone

d eksgjk dk;Z izFkd ls en 06040 o 06041 ds vUrxZr ekik tk;sxkA

06034 pkSdksj vux<+ tks/kiqj fdLe ds iRFkjksa dks


lw[kk iw.kZr% vkc fcNkdj Lrj rd nhokj
cukuk

Cement lime Cement mortar


mortar lhaeV
s lhaesV elkyk

pwuk elkyk

pwuk elkyk
1:3
Rs.

1:2
Rs.

1:1:8
Rs.

1:6
Rs.

1:4
Rs.

1386.40

1414.10

1252.20

1524.70

1711.70

905.90

933.80

771.60

1044.10

1320.40

1434.00

1462.00

1299.80

1572.30

1759.30

953.40

981.40

819.20

1091.70

1278.20

06039Add to items 06035 to 06038 for


squared rubble walling, Jodhpur
type, brought to courses and regular
coursed, curved on plan to a mean

radius n exc 6m

M&L

Except stone

lkezzxh o Je

iRFkj jfgr

Rs.

Rs.

108.40

60.80

06035 tks/kiqjh fdLe ds pkSdksj


vux<+ iRFkjksa dks iw.kZr%
vko djds bl elkys
esa Bksl fcNkdj Lrj rd
nhokj cukuk
06036 mi;qDZ r] fdUrq iRFkj jfgr
06037 tks/kiqjh fdLe ds pkSdksj
vux<+ iRFkjksa dks iw.kZr%
vko djds bl elkys
ls Bksl Lrj rd dh
nhokj cukuk
06038 mi;ZqDr] fdUrq iRFkj
jfgr

06039 tksM+ a s en 06035 ls 06038 es]a pkSdksj vux<+


tks/kiqj fdLe ds iRFkj dh Lrj rd ykih
xbZ rFkk fu;fer Lrfjr( vk;kstu ij
vkSlru 6 eh vuf/kd] ds fy;s

FACING TO STONE WALLING JODHPUR TYPE


tks/kiqj fdLe ds iRFkj dh nhokj dk eksgjk cukuk
(a) Each finished face shall be measured.
d izR;sd ifjd`r eksgjk ekik tk;sxkA
(b) 50 per cent extra shall be allowed for facework to walls [k vk;kstu ij 6 eh ls vuf/kd o ij cuh nhokjksa ds eksgjk dk;Z
built to a curve n. exc 6m mean radius. This allowance
ds fy;s 50 izfrkr vfrfjDr Lohdkj fd;k tk;sxkA
includes for all cutting and waste, templates etc.
(c) 25 per cent shall be allowed for facework to battered
or tapered wall.
PER SQUARE METRE
06040Extra over items 06035 and 06036 for hammer
dressing to face stones with maximum
depression on face from a straight edge not
exc 20mm and dressing face beds and joints
as specified to squared rubble walling,
Jodhpur type, brought upto courses
06041Extra over items 06037 and 06038 for ditto
to squared rubble walling, regular coursed,

Jodhpur type

x 25 izfrkr vUrjh; ?kqekoh o kq.Mkdkj nhokjksa ds eksgjk dk;Z


ds fy;s Lohdkj fd;k tk;sxkA
izfr oxZ ehVj
06040 en 06035 o 06036 ij vfrfjDr vf/kdre ncko
Rs.
ls eksgjk iRFkjksa dks /kqjeqV ls fdukjs ls 20 feeh ls
vuf/kd ij dqVkbZ djuk rFkk pkSdksj tks/kiqj fdLe
ds iRFkj dh Lrj rd ykbZ nhokj ds eksgjs vk/kkj

o tksMksa dk fufnZVkuqlkj ifjd`r djuk


79.30
06041 vfrfjDr] en 06037 o 06038 ij mi;qZDr ds fy;s
119.00
fdUrq u;fer Lrfjr

85

SECTION 6

SECTION 6STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
EXTERNAL ANGLES (QUOINS AND JAMBS)
ckgjh dks.k dksfu;ka o ik[ks
(a) Exposed finished faces of quoins and jambs shall be d dksfu;ka o ik[kksa ds [kqys ifjLd`r Hkkxksa dks *eksgjk* dk;Z ds lkFk
measured along with 'facings'.
ekik tk;sxkA
(b) The rates do not include for chisel drafted margins at the [k njksa esa] dksfu;ka o ik[kksa ds dksuksa ds gkfk;ksa mikUr dh Nsuh
corner of quoins and jamb stones.
NVkbZ kkfey ugha gSA
(c) 50 per cent extra on items 06042 to 06048 shall be allowed x vle dks.kksa o foLQkfjr dks.k ds fy;s en 06042 ls 06048 ij
for squints and birdsmouths.
50 izfrkr vfrfjDr Lohdkj gksxkA
izfr ehVj dks.k dk

PER RUNNING METRE (OF ANGLE)


06042 External angles (for quoins and jambs) in
facings for walling of random rubble or
polygonal rubble, uncoursed or brought upto
courses and squared rubble masonry, regular

coursed, Secunderabad and Bangalore types


06043 Ditto for walling of squared rubble,

uncoursed or brought upto courses


06044 Ditto for walling of squared rubble, regular

coursed

06045 Ditto for block-in-course walling

06046 Ditto for ashlar walling

Rs.

60.80
76.70

06042 vleku] vux<+ iRFkjksa dh ;k cgqHkqth vux<+ iRFkjksa


dh vuLrfjr ;k Lrj rd rFkk pkSdksj vux<+
fldUnjkoknh o caxykSjh iRFkj dh fpukbZ ds eksgjksa esa
ckgjh dks.k dksfu;k o ik[ks
06043 mi;qZDr] pkSdksj vux<+] vuLrfjr ;k Lrj rd vkbZ
nhokj ds fy;s
06044 mi;ZqDr] pkSdksj vux<+ fu;fer Lrfjr nhokj

84.60

06045 mi;ZqDr] Lrfjr esa [kaMd fu;fer nhokj ds fy;s


06046 mi;qZDr] vLyj nhokj ds fy;s
06047 mi;qDZ r] pkSdksj vux<+ tks/kiqj fdLe] Lrj rd ykbZ
06047 Ditto for squared rubble walling Jodhpur
52.90

type, brought upto courses


xbZ nhokj ds fy;s
58.20 06048 mi;qZDr] fu;fer Lrfjr

06048 Ditto, regular coursed


ARCHES MkVsa esgjkc] pki
Exposed finished faces shall be included in the dimensions for [kqys ifjd`r Hkkxksa dks **eksgjksa** ds ifjeki esa feyk;k tk;sxkA
166.60
224.70

facings.

195.60
523.50

izfr oxZ ehVj


06049 vfrfjDr] vleku ;k cgqHkqth vux<+ iRFkjksa dh
MkVksa ds fy;s vleku vux<+ tSls eksgjk dk;Z ds
fy;s fdUrq fufnZVkuqlkj MkVksa ds vUnj ;k ckgj
fdlh Hkh izdkj dh eksVh dVkbZ lfgr laf/k fofdj.k
djus ds dk;Z ij
06050 vfrfjDr] MkVksa ds pkSdksj vux<+ iRFkjksa ds eksgjksa dh
vk/kkj o laf/k;ksa dh fufnZVr le:i ifjd`fr djus ds
fy;s fokerkvksa o MkV ds vUnj o ckgj dh lqUnj
dVkbZ izFkd ekih tk;sxh
06051 vfrfjDr] Lrj esa [kaMd eksgjs ij mi;ZqDr

489.10

06052 vfrfjDr] vLyj fpukbZ ds eksgjs ij mi;ZqDr

PER SQUARE METRE


06049 Extra over random or polygonal rubble
facings for arches with facework as on
random rubble, but joints radiating,
dressed as specified including any rough
cutting over and under arches
06050 Extra over squared rubble facings for
arches finished to match the facings with
beds and joints as specified (Fair cutting
for skews and over and under arches to

be measured separately)
06051 Extra over block-in-course facing ditto (Ditto)

06052 Extra over ashlar facings ditto (Ditto)

Rs.

97.80

PER RUNNING METRE


06053 Fair cuttings (straight or circular) to
facings of squared stone of any description
except ashlar, 7.5cm in depth as for skew

backs or over and under arches, etc.

44.60

06054 Ditto (ditto) to ashlar facings (any finish


to face) 7.5cm in depth as for skew backs

or over and under arches, etc.

50.20

iz f r ehVj
06053 fdlh Hkh izdkj dh vLyj dks NksM+dj iRFkjksa ds
eksgjksa dh] MkVksa ds vUnj o ij ;k foke izBksa
tSlh 7-5 lseh xgjh] eghu lh/k ;k xksy dVkbZ
djuk
06054 mi;ZDq r] mi;ZDq r vLyj eksgjksa ij dksbZ ifjd`fr 7-5
lseh xgjh MkVkss a ds foke izBksa ;k vUnj o ij tSlh

86

SECTION 6

SECTION 6STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
BOULDER WORK
xksyk iRFkj dk;Z
;fn xksyk iRFkj ds LFkku ij Lohd`r [kuu iRFkj dks fcuk rjk'ks
eksVs rkSj ij fufnZ"V xksyk iRFkj ds uki dk cukdj iz;ksx fd;k
tkrk gSA rks ;g njsa ml ij Hkh ykxw gksaxhA

The rates in this table shall also apply if approved undressed


quarried stones roughly conforming to specified size of boulders
are used in lieu.
PER CUBIC METRE
06055 Boulder filling dry, handpacked
tightly, as in wire crate apron bunds

(Wire crate measured separately)


06056 Ditto in vertical bunds with

sloping face
06057 Boulder pitching, laid dry, hand

packed tightly
06058 Add to Item 06057 if pitching is
grouted with cement and sand

mortar 1:6

M&L

Except boulders

lkexzh o Je

xksyk jfgr

Rs.

Rs.

593.80

162.00

729.30

266.70

767.40

304.70
Rs.

izfr ?ku ehVj


06055 gkFk ls ladfq yr djrs gq;]s rkj daMh vkoj.k
ca/kksa tSlh] xksy iRFkj dh mlkBl lw[kh HkjkbZ
djuk rkjdaMh izFkd ekih tk;sxh
06056 mi;qDZ r] <kyw iz"B okys [kM+s oU/kksa
es a
06057 gkFk ls ladqfpr djrs gq;s xksyk iRFkj
dks lw[kk fcNkuk fcBkuk
06058 tksM+sa en 06057 esa ;fn iRFkjksa dk
fcBkus dk dk;Z 1%6 lhesaV ckyq ds
elkys dh HkjkbZ ls gqvk gS

361.00

CUTTING OPENING FOR DOORS, WINDOWS, ETC. AND MAKING GOOD


f[kM+dh njoktksa vkfn ds fy, focj [kqyk LFkku dh dVkbZ djuk vkSj Bhd djuk
(a) The amount of cutting-through measured shall be the net d okLrfod dkVh xbZ nhokj ds ctk;] dkV ds ifj"d`r focj dh
size of the finished opening irrespective of the amount of
'kq) eki gh ifjeki gksxkA flyksa] MkVksa] /kkjd dfM+;ksa] fyaVyksa
walling actually cut out. The net cubic contents of cills,
vkfn ds ?kuRo dks tksM+k tk;sxkA nhokj dh eksVkbZ] iyLrj]
arches, bressummers, lintels, etc., shall be allowed in
fyikbZ] eksVh x<+kbZ vkfn dks NksM+dj yh tk;sxhA
addition. The thickness of wall shall be measured exclusive
of plastering, rendering, rough cast etc.
(b) If existing openings are enlarged, the net contents of the
original opening shall be deducted from the net contents of
the new opening.
(c) The area payable for forming jambs shall be the net area
(excluding the thickness of plaster) of the inner vertical
sides of the opening. The rates for forming jambs include
cutting, toothing and bonding the new to the old.
(d) For measuring making good to heads and cills, the length
plus depth at each end, shall be multiplied by the thickness
of wall. The rates for making good include for cutting and
pinning in cills, heads, lintels, bressummers, etc.
(e) The following in making good shall be measured separately:
(i) New arches.
(ii) New cills, heads, lintels, girders, etc. and hoisting and
setting same (but not cutting and pinning).
(iii) The cost at supplied only rates of new stone required
for making good. The old stones cut out are, however,
to be re-used, as far as practicable.
(iv) All dressings worked on existing or new stone.
(v) Making good plastering, rendering, etc. around the
finished opening.
Note: For cutting holes n exc. 0.10 sq. m in area in stone
walls, see Section 5Brickwork.

[k ;fn ekStwnk focjksa dks c<+kuk gS rks u;s fooj ds dqy ;ksx esa
ls iqjkus fooj ds dqy ;ksx dks ?kVk;k tk;sxkA
x i[[ks cukus dk ns; {ks=Qy] fooj ds vUnj dh Hkqtkvksa dk
fo'kq) {ks=Qy iyLrj dh eksVkbZ NksM+dj gksxkA i[[kksa dh
cukbZ dh njksa es]a dVkbZ] nkars fudkyuk rFkk iqjkus dk;Z esa uohu
dk;Z dks feykuk 'kkfey gSA
?k 'kh"kZ o flyksa ds ifj"d`fr ds dk;Z dks ekius ds fy;s] yEckbZ tek
izR;sd Nksj dh xgjkbZ xq.kk nhokj dh eksVkbZ gksxhA ifj"d`fr ds
dk;Z dh njksa es]a dVkbZ] rFkk flyksa 'kh"kks]Z fyaVyks]a vk/kkj dfM+;ksa
vkfn esa jsrh HkjkbZ 'kkfey gSA
M+ ifj"d`fr esa fuEufyf[kr izFkd ekis tk;saxs%&
1 uohu MkVsa egjkosa
2 uohu flysa] 'kh"kZ] fyaVyksa] xkMZj vkfn rFkk mudks mBkuk
o yxkuk fdUrq dVkbZ o jsrh HkjkbZ ugha
3 ifj"d`fr ds fy;s visf{kr uohu iRFkj dh dsoy vkiwfrZ
njksa ij ykxr
4 iqjkus ;k u;s iRFkj dh leryhdj.k ds lHkh dk;Z
5 laifw jr fooj dh ifj"d`fr ds fy;s iyLrj ;k fyikbZ dk;Z
uks V %

iRFkj dh nhokj ds 0-10 oxZ eh vuf/kd dh Nsn


dVkbZ ds fy;s [kaM 5& bZV dk;Z ns[ksaA

87

SECTION 6

SECTION 6STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
CUTTING OPENINGS FOR DOORS, WINDOWS, ETC. AND MAKING GOODContd...
f[kM+dh njoktksa vkfn ds fy, focj [kqyk LFkku dh dVkbZ djuk vkSj Bhd djuk tkjh
PER CUBIC METRE
06059Cutting openings through walls
for door, window and other
openings or enlarging existing
openings, etc., or cutting out
defective masonry for underpinning including providing,
fixing and removing, shoring,
cleaning and stacking stone
and removing surplus to store

and rubbish off the premises

PER SQUARE METRE


06060Forming jambs, etc., to openings (to foregoing item), with
stone supplied by MES
including cutting, toothings and
properly bonding into old work,
including facing and pointing
(if necessary) to match existing

work, complete
06061Making good under cills (or
over arches, lintels and
bressummers) including all

pinning as necessary

izfr ?ku ehVj


iqjkuh fpukbZ var%fufeZr
06059
06059njoktksa] f[kM+fd;ksa o vU; fooj ds
Mud
Lime
Cement
fy;s nhokjksa esa fooj dVkbZ ;k ekStwnk
mortar
mortar
mortar
fooj dks c<+kuk vkfn ;k HkjkbZ ds fy;s
[kjkc fpukbZ dks dkV fudkyuk] Vsdcanh
feh xkjk
pwuk elkyk
lhesaV elkyk
dh O;oLFkk] yxkuk o gVkuk lfgr]
Rs.
Rs.
Rs.
lQkbZ djuk o iRFkjksa dk tek djuk
rFkk Qkyrw iRFkjksa dks Hk.Mkj igqp
a kuk

o eyos dks ifjlj ls ckgj Qsaduk


262.20
381.30
493.70
Old masonry walls built in

510.30

izfr oXkZ ehVj


06060
06060fooj esa i[[ks vkfn esa ij dh en
ds ,e bZ ,l }kjk iwfjr iRFkjksa ls]
dVkbZ nkars fudkyus o iqjkus dk;Z ls
vPNh rjg feykus o eksgjs cukbZ o Vhi
dk;Z ;fn vko';d gks lfgr i[[ks
vkfn cukuk iqjkus dk;Z dk feyku djrs
gq;s laifw rZ

379.20

06061
06061flyksa ds uhps dh ifj"d`rh djuk ;k
MkVksa] fyaVyksa o vk/kkj dfM+;ksa ij
vko';drkuqlkj lHkh jsrh HkjkbZ lfgr

New work built in


uohu dk;Z var%fufeZr
Lime
Cement
Cement
mortar mortar 1:6
mortar 1%4
pwuk elkyk lhesaV elkyk
lhesaV elkyk
1%3
1%6
1%4
Rs.
Rs.
Rs.
369.90

285.10

453.50

331.40

CUTTING CHASES, REBATES ETC. IN EXISTING WALLS


orZeku nhokjksa esa [kkaps] f>jh dh dVkbZ djuk
(a) See Section 5Brickwork, Items shall be as per brick work
Section.
(b) Dressing (facework) of chases, rebates, etc. as required shall
be measured separately.

d [kaM 5 bZV dk;Z dh en nsa[ksaA

(a) To be measured on the vertical face in contact with new


wall only.
(b) New stone or brick work built into the toothings shall be
measured alongwith the new wall taking an average
dimension for the depth of new materials.
(c) Atleast one stone to be cut for every 0.2 sq.m in case of
rubble and regular coursed walling and stones in alternate
courses for block in course and ashlar walling.

d dsoy ubZ nhokj ds laidZ esa [kM+h lrg dks ekik tk;sxkA

[k [kkapks]a f>fj;ksa vkfn dk visf{kr izlk/ku dk;Z eksgjk dk;Z izFkd


ekik tk;sxkA
CUTTING AND FORMING TOOTHING TO STONE WALLS
iRFkj dh nhokjksa esa [kkaps] f>jh dh dVkbZ djuk o nkars fudyuk

[k nkarks ds vUnj cus u;s iRFkj ;k bZV dk;Z] ubZ lkexzh ds vkSlr
ifjeki dh nhokj ds lkFk ekis tk;saxsA
x vux<+ o fu;fer Lrfjr nhokj dk;Z rFkk Lrj esa [kaMd o
vLyj nhokjksa ds fy;s ifjorZd Lrj esa iRFkj ds ekeys esa de
ls de ,d iRFkj dh 0-2 oxZ ehVj dh dVkbZA

88

SECTION 6

SECTION 6STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
CUTTING AND FORMING TOOTHING TO STONE WALLSContd...
iRFkj dh nhokjksa esa dVkbZ djuk o nkars fudkyuk &tkjh
PER SQUARE METRE

Old masonry walls built in

izfr oxZ ehVj

iqjkuh fpukbZ var%fufeZr

06062Cutting into old masonry to form


toothings for and bonding in new
brick or stone work including
making good in mud mortar
06063Ditto, but making good in lime
or cement mortar of the same

mix as for new walling.

Mud

Lime

Cement

mortar

mortar

mortar

feh xkjk

pwuk elkyk

lhesaV elkyk

Rs.

Rs.

Rs.

87.20

148.00

190.80

130.70

153.50

185.30

06062 nkars cukus ds fy;s iqjkuh fpukbZ esa


dVkbZ djuk rFkk feh xkjs esa ifj"d`r
djus lfgr] u;s bZV dk;Z ;k iRFkj
dk;Z ls feykuk
06063 mi;qDZ r] fdUrq uohu dk;Z leku pwuk
;k lhesVa elkys ls

PREPARING UNCOURSED STONE WALLS FOR CONCRETE BAND COURSES, BRICK


COURSES, BOND COURSES OF MASONRY IN RICHER MIX, ETC.
vuLrfjr nhokjksa dks dhV can Lrjksa] bZV Lrjksa] izpqj feJ.k dh fpukbZ ds ca/k Lrj vkfn rS;kj djuk
Payment under these items shall not be admissible for bringing
uncoursed work to level finish at the lop of plinths, cill and lintel
of opening and at top, which is included in the rates for walling.

vuvLrfjr dk;Z dks dqlhZ ds 'kh"kZ ij ls laifw jr ry ij ykus] focj


ds fly o fyaVy rFkk 'kh"kZ ds dk;ksZ dh Lohd`fr bu njksa ds vUrxZr
ugha gksxh] ;g dk;Z nhokj fpukbZ esa 'kkfey gSA

PER SQUARE METRE

izfr oxZ ehVj

06064Levelling and preparing uncoursed


random or polygonal rubble walls to
receive concrete band courses, brick

courses, bonding courses, etc.


06065Ditto uncoursed squared rubble walls ditto

Rs.

45.60
35.70

06064 dahV iV~V Lrj] bZV Lrj] c/kad Lrj vkfn yxkus
ds fy;s fcuk rjk'ks vleku ;k cgqdks.kh; iRFkjksa
dh nhokj dks lery djuk o rS;kj djuk
06065 mi;qZDr] fcuk rjk'ks pkSdksj vux<+ nhokjsa]
mi;qZDr

DRESSED STONE WORK


izlkf/kr iRFkj dk;Z
(a) The rates in the following table include for all labour, waste, d fuEu lkj.kh dh njksa esa lHkh izdkj dk Je] Nhtu] mPpkyu] tekuk]
hoisting, setting, jointing with struck joints and cleaning
lajpuk tksMk+ as ls tksMu+ k lQkbZ vkfn djds lai.w kZ djuk 'kkfey gSA]
down complete.
[k
eki
djus ds rjhds ds fy;s 6-1-2 ns[ksaA
(b) For method of measurement see special conditions here- in
before 6.1.2.
(c) The rates against items 06066 to 06070 are for stone in
block work, each stone not exceeding 1m in length or 60
cubic decimetres (dm3) in volume.
(d) The rates in the table below are for punched dressed
finish to faces, and rough tooled finish to beds and joints,
and include all preliminary labour and such other extra
labour that may be required to comply in every respect
with the description of the different items.
(e) The rates also include for slate or stone dowels, cement
joggle joints and cutting grooves for metal cramps, tongues
etc. and setting the same in neat cement. Metal cramps,
tongues, etc., shall be measured separately and paid for at
supplied only rates.

x en 06066ls 06070 dh njs]a [kaMd dk;Z esa iRFkj tks yEckbZ esa 1 ehls vuf/kd ;k ifjeki esa 60 ?ku MslhehVj Mh,e gks] ds fy;s gSA
?k uhpsa dh lkj.kh dh njsa eksgjksa dh Vkafpr izlkf/kr ifj"d`fr rFkk
vk/kkj o tksMk+ as dh eksVh e'khuh ifj"d`fr ds fy;s gSa rFkk lHkh
izkjfEHkd Je o ,sls vU; Je ftldh fofHkUu enksa esa of.kZr dk;ksZ
dks iwjk djus ds fy;s vko';drk gks ldrh gS] 'kkfey gSAa
M- bu njksa esa iRFkj ;k Mkcsy iRFkj] lheaVs xq>h tksM+ rFkk /kkrq ds
f'kdatks]a fpeVksa vkfn ds fy, [kkapksa dh dVkbZ o mUgsa 'kq) lhesVa
ls fcBkuk Hkh 'kkfey gSA /kkrq ds f'kdats fpeVs vkfn izFkd ekis
tk;sxas rFkk mudk Hkqxrku ^^dsoy liwfa rZ nj** ij gksxkA

89

SECTION 6

SECTION 6STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
DRESSED STONE WORKContd...
izlkf/kr iRFkj dk;Z &tkjh
PER CUBIC METRE
Stone in block, set in lime mortar
1:3 or cement mortar 1:6 (as
directed) in :-

06066Bands, string and plinth


courses, blocking courses,

plain pillasters, etc.


06067Ditto but moulded; also
moulded and weathered
cornices, and window cills
(sunk, weathered, throated,
grooved for tongue, including stopped ends, stools

and returned fair ends)


06068Quoins, jamb stones, door
or window heads, plain
corbels, door cills, plain
steps, parallel copings

with throated edges, etc.


06069Kneelers, arch stones, key
blocks, etc, with or without
chamfered markings and
feather edge or saddle-back copings (with throated edges)
06070Shafts of circular columns
(swelled or diminished) including moulded caps and
base to columns
06071Add to the foregoing for
lengths exc 1m and n exc
2m or exc 60 and n exc 180

dm3 in volume in a block


06072Add to items 06066 to
06070 if face stones are close

picked dressed
06073Add to items 06066 to
06070 if face stones are fine

tooled
06074Setting only dressed masonry, any description and
in any position (exclusive
of dressed stones but
including mortar)

Granite or trap
stone

Lime or sand stone

pwuk ;k cyqvk iRFkj

xzsukbV ;k Vi
iRFkj
Straight
work

Circular
work

Straight
work

Circular
work

lh/kk dk;Z xksy dk;Z

lh/kk dk;Z

xksy dk;Z

Rs.
8497.20

Rs.
5410.00

Rs.
7366.40

Rs.
12409.90

12337.30 18880.50

7366.40

10538.90

9607.60

14934.70

6150.30

8441.50

11008.70 16428.40

6613.00

9415.30

14842.10 21478.00

8119.90

11953.30

470.00

704.70

232.00

352.40

488.50

749.70

277.00

440.40

1919.40

2336.40

1429.70

1628.30

izfr ?ku ehVj


izLrj [kaM 1%3 ds pwuk elkys ;k 1%6 ds
lhesVa elkys funsfZ 'kr bl dk;Z es%a &

06066
06066caSM] ekyk o dqlhZ pkyks] ca/ku
pkyksa] lknk iyLrj vkfn
06067
06067mi;qZDr] fdUrq lkafpr( lkafpr o
Nkfnr dkfuZl o f[kM+dh flysa
fueju] lkafpr] mijks/kh] fpeVksa
ds [kkaps] ca/kd fdukjs LVwy o
eqM+s eghu fdukjs

06068
06068dksfu;k i[[ks iRFkj njokts ;k
f[kM+fd;ksa ds 'kh"kZ] lkns] VksMs]
njokts dh fly] lkns in] dkaBs]
lekukUrj eqaMsj fdukjs vkfn
06069
06069jksd iRFkj] MkV iRFkj] dqt
a h iVy
vkfn] i[knkj ;k i[k jfgr rFkk]
ruqikr ;k dkBh iz"B eqM
a js s dnBh
fdukjs
06070
06070xksy LrEHkksa ds 'kSV mHkjh ;k
?kVkoh lkfpr 'kh"kZ o LrEHk ds
vk/kkj lfgr
06071
06071tksM+sa ij dh en esa 1 eh ls
vf/kd o nks eh ls vuf/kd yEckbZ
;k ,d [kaM dk ifjeki esa 60 ls
vf/kd o 180 Mh ,e3 vuf/kd
06072
06072tksMas+ en 06066 ls 06070 esa ;fn
eskgjs ds iRFkj BlkBl izlkf/kr
gSaA
06073
06073tksM+sa en 06066 ls 06070 esa
;fn eskgjs ds iRFkjksa dh e'khu ls
ckjhd fNykbZ dh gS
06074
06074fdlh Hkh izdkj dh rFkk fdlh Hkh
fLFkfr es a fpukbZ dk ds o y
lek;kstu rjk'ks iRFkj jfgr fdUrq
elkys lfgr

90

SECTION 6

SECTION 6STONE MASONRY


[k.M 6& iRFkj dh fpukbZ
DRESSED STONE SLABS IN COPINGS, WINDOW CILLS, ETC.
eqaMsjksa] f[kM+dh flyksa esa rjk'kh iRFkj if;ka
PER SQUARE METRE
06075Stone slab 25 mm to 35 mm
thick dressed true and
square, in one length not
less than 60cm and n. exc
120cm in copings, window
cills, chajjas, sunshades,
etc., punched dressed on
exposed faces and self faced
on
the
embedded
unexposed beds and joints;
exposed edges rounded or
chamfered as directed, set,
jointed and pointed in

mortar

M&L

Except stone slabs

lk o Je

iRFkj ifV;k jfgr

Lime
mortar

Cement
mortar

Lime
mortar

Cement
mortar

pwuk elkyk

pwuk elkyk

1%2

lhesVa
elkyk
1%4

1%2

lhesVa
elkyk
1%4

Rs.

Rs.

Rs.

Rs.

305.00

323.20

85.20

103.50

izfr oxZ ehVj


06075
0607525 feeh ls 35 feeh eksVh vPNh
rjg rjk'kh gqbZ o pkSdksj yEckbZ esa
60 lseh ls de ugha o 120 lseh ls
vuf/kd iRFkj dh ifV;k eqM
a js ks]a
f[kM+dh flyks]a NTtks]a Nrjh vkfn esa
ij eksgjs ij fNfnzr rjk'kh rFkk
var% fufeZr Nqis vk/kkj o tksMk+ sa esa
Lor% iz"Bh] ckgjh fdukjs xksys fd;s
gq;s ;k tSlk funs'Z k gks uksdnkj] iRFkj
dh ifV;ksa dks fcBkuk] tksMu+ k rFkk
Vhi djuk] bl elkys es-a ------

DRESSED STONE SLABS IN SHELVES, CHAJJAS, ETC.


dxkjksa] NTtksa vkfn esa rjk'kh iRFkj ifV;ka
In the case of continuous sun-shades, chajjas and shelves, etc.
edges of stone slabs at joints of projecting portion shall be rough
tooled dressed.
PER SQUARE METRE
06076Sand stone slabs in
sun-shades,
chajjas,
shelves, cills, landings,
cover stones, templates, etc.
n exc. 2m in length,
punched dressed on face
and along exposed edges,
self faced on other side and
set and pointed in lime
mortar 1:2 or cement
mortar 1:4. complete
06077Lime stone slabs in ditto, set
and pointed in lime mortar
1:2 or cement mortar 1:4,

complete

lrr /kwiNkou] NTts o dxkjksa vkfn ds ekeys esa tksMk+ as ds lek;kstu


fcUnq ij iRFkj dh ifV;k ds fdukjksa ij eksVk e'khuh izlk/ku gksxkA

Thickness of slabs

Except
stone
Slabs

ifV;ksa dh eksVkbZ

ifV;k
jfgr
3cm
Rs.

5cm
Rs.

7.5cm
Rs.

10cm
Rs.

Rs.

271.50 314.20

347.80

110.50

274.10

izfr oxZ ehVj


06076
06076/kwi Nknuks]a NTtks]a dxkjks]a flyks]a
pkSfd;ks]a vkoj.k iRFkjksa vk/kkj iV
vkfn tks 2 eh ls vuf/kd yEckbZ
esa cyqvk iRFkj ifV;k dk;Z tks
,d vksj o ckgjh fdukjs lkafpr
izlkf/kr rFkk nwljh vksj ls Lor
xf<r rFkk mudks 1%2 ds pwuk
elkys ;k 1%4 ds lhesVa elkys esa
yxkuk o Vhi djds iw.kZ djuk
06077
06077pwuk iRFkj ifV;k mi;qDZ r es]a 1%2
ds pwuk elkys ;k 1%4 ds lhesVa
elkys esa Vhi djds iw.kZ djuk

91

SECTION 6

SECTION 6 STONE MASONRY

[k.M 6& iRFkj dh fpukbZ


JODHPUR STONE LINTELS AND BEAMS

tks/kiqjh iRFkj ds ljny fyaVy rFkk /kju 'kgrhj


Where two stones are used to make the width, the rates for
lintels and beams include grouting between the two stones in
cement mortar 1:3.
PER CUBIC METRE
06078 Roughly squared stone lintels
hammer dressed on face and soffits,
hoisted, set and pointed in lime
mortar 1:3 or cement mortar 1:6
complete, n exc 3m in length

tgka pkSMk+ bZ esa nks iRFkj iz;ksx fd;s tkrs gS]a ogka njksa esa ljny o /kju
esa nks iRFkjksa ds chp 1%3 ds lhesVa elkys dh HkjkbZ 'kkfey gSA

M&L

Except stone

lk o Je

iRFkj jfgr

Rs.

Rs.

1601.00

1072.30

izfr ?ku ehVj


06078 eksVs rkSj ij pkSdksj fd;s iRFkj ry o eksgjs
ij gFkksMs+ ls rjk'ks] yEckbZ esa 3 eh ls vuf/kd
ds ljnyksa esa 1%3 ds pwuk elkys ;k 1%6 ds
a elkys ls fcBkuk o Vhi djds iw.kZ djuk
lhesV

STONE CHOWKATS FOR DOORS, WINDOWS, ETC.

njokts f[kM+fd;ksa vkfn dh iRFkj dh pkS[kVsa


The rates include for making holes and recesses for fixing
of hinges, bolts etc. The rates also include for fixing of
horns. The length shall be measured out to out and length
of horns and portion embedded in floor shall be added in
addition.
PER RUNNING METRE

M&L

06079 100x75mm, rebated, karoli stone


chowkats with exposed faces close
picked dressed, including 4 bolt
holes per upright, erected in
position and bedded and pointed
in lime mortar 1:3 or cement mortar
1:6 (Bolts measured separately)

lk o Je

06080 All as above but 125mm x 75mm in

section (ditto)
06081 Add to items 06079 and 06080 for

additional rebate

Rs.

bu njksa esa dCts] dkoys vkfn yxkus ds fy, Nsn o f>fj;ka


fudkyuk 'kkfey gSA njksa esa Jzx
` h yxkuk Hkh 'kkfey gSA yEckbZ ckgj
ls ckgj ekih tk;sxh rFkk Ja`xh dh yEckbZ o Q'kZ esa yxs Hkkx dks
blesa tksMk+ tk;sxkA

iz f r ehVj
06079 100 75 feeh dh irkeh] djkSyh iRFkj dh
iRFkj pkS[kV jfgr
pkS[kVsa lkeus ls l?ku Blh x<+kbZ lfgr ij
Rs.
tkrs LFkkiu esa cus 4 dkoys ds Nsn rFkk 1%3
ds pwuk elkys ;k 1%6 ds lhesV elkys esa
yxkuk o Vhi djuk dkoys izFkd ekis tk;sxa s
Except stone
chowkats

224.20

20.20

225.20

23.80

100.00

25.20

06080 lc ij ds leku fdUrq 125 75 feeh


[kaM es]a mi;qDZ r
06081 en 06079 o 06080 esa vfrfjDr irke ds
fy;s tksMsa+

JODHPUR STONE SLAB ROOFING

tks/kiqjh iRFkj ifV;k dh Nr Mkyuk


`

PER SQUARE METRE


06082 Jodhpur stone roof slabs, self faced
7.5cm to 10cm thick, 25cm to 35cm
wide, hoisted and set, jointed and
grouted in lime mortar 1:3 or

cement mortar 1:6 complete


06083 Ditto and set in cement mortar 1:3,

complete

M&L

lk o Je
Rs.
619.00
636.10

izfr oxZ ehVj


06082 7-5 lseh ls 10 lseh eksVs 25 ls 30 lseh
pkSM+h tks/kiqj iRFkj dh Lo;a xfBr ifV;ksa
iRFkj ifV;k jfgr
dks mBkdj] 1%3 ds pwuk elkys ;k 1%6 ds
Rs.
lhesaV elkys es LFkkfir djuk] tksM+uk o
187.20
Vhi djds iw.kZ djuk
06083 mi;qDZ r] rFkk 1%3 lhesVa elkys esa LFkkfir
204.30
djds iw.kZ djuk
Except stone
slabs

92

SECTION 6

SECTION 6 STONE MASONRY

[k.M 6& iRFkj dh fpukbZ


JODHPUR STONE SLAB ROOFING & Contd..

tks/kiqjh iRFkj ifV;k dh Nr Mkyuk & tkjh


PER SQUARE METRE

M&L

izfr oxZ ehVj

Except stone
slabs

lk o Je

iRFkj ifV;k jfgr


06084 Ditto as in item 06082 but exc 10cm

and up to l2.5cm thick

Rs.

Rs.

656.00

187.20

06085 Ditto as in item 06083 but exc. 10

cm and upto 12.5 cm thick

673.10

204.30

06086 Jodhpur stone slab patties self


faced, 7.5cm thick laid dry in single
width in trenches as covering to

cables etc.

06084 mi;qZDr] tSlh en 06082 esa gS fdUrq 10


lseh ls vf/kd o 12-5 lseh rd ehVh
06085 mi;qZDr tSlk en 06083 esa gS fdUrq 10
lseh ls vf/kd o 12-5 lseh rd eksVh
06086 7-5 lseh eksVh tks/kiqj iRFkj dh Lo;a xfBr
ifV;k dks bdgjh pkSMk+ bZ esa dsoy vkfn dks
<dus ds fy, [kkb;ksa esa lw[kk fcNkuk

MORTICES

eksjfVl pwy lqjk[k


The rates apply to work on dressed stone either already
built in or on the banker.
PER 100 CUBIC CENTIMETRES

;g njsa ;k rks igys ls gh var% fufeZr ;k cadj ij rjk'ks gq;s iRFkj


ij ykxw gksrh gSaA
izfr 100 ?ku lsaVh ehVj

Materials and Labour

lkexzh o Je
Granite or
trap stone

Lime or sand
stone

06087 Mortices, rectangular or dovetailed, xzSukbV ;k


etc., for balusters, dowels, lewis- c/kaqvk iRFkj
bolts, newels, etc. exc. 50 but n exc
Rs.
150 cubic centimetres and run with
47.40

neat cement

pwuk ;k cyqvk
iRFkj
Rs.
24.20

EACH
06088 Ditto n exc 50 cubic centimetres

31.90

14.40

06087 taxys dh NM+k]s fxV`Vdks]a ySfcl dkoys] lh<+h ik;s]


vkfn esa 50 ls vf/kd fdUrq 150 ?ku lseh- vuf/kd
ds] vk;rkdkj ;k diksr iqPNh vkfn ds fy, 'kq)
lhesV
a dh pky ds lkFk lqjk[k cukuk
izR;sd
06088 mi;qZDr] 50 ?ku lseh ls vf/kd ugha

LABOURS ON DRESSED STONE

rjk'ks gq;s iRFkj ij Je ewY;


(a) The rates in the following table are for straight work.
Circular work shall be paid for at twice and circular,
circular work at four times the rates for straight work.

d fuEufyf[kr lkj.kh dh njsa lh/ks dk;Z ds fy;s gSaA xksykdkj


dk;Z dh nqxuh nj nh tk;sxh rFkk xksykdkj] xksykdkj dk;Z
ij lh/ks dk;Z dh njksa dk pkjxquk fn;k tk;sxkA
(b) The rates apply to work on the banker. If necessarily [k ;g njsa cadj ds dk;Z ij ykxw gksrh gSaA ;fn vfuok;Z :i ls
executed on stone already built in, 50 percent extra
fu"iknu igys ls var%fufeZr iRFkj ls gksrk gS rks 50 izfr'kr
shall be allowed. No extra allowance shall, however,
vfrfjDr fn;k tk,sxkA cjesa ds Nsn ds fy,s fQj Hkh] dqN Hkh
be made to the items of drillholes.
vfrfjDr ugha fn;k tk;sxkA
(c) The following rates are extra to quarry scabbled stone x fuEu njsa iiM+hnkj [kuu iRFkj dh vfrfjDr njs gSa rFkk vU;
and apply to labours not included in other items.
enksa esa 'kkfey ugha fd;s x;s Je ij ykxw gksrh gSaA
(d) The rates do not apply to stone walling.
?k ;g njsa iRFkj ds nhokj dk;Z ij ykxw ugha gksrhA

93

SECTION 6

SECTION 6 STONE MASONRY

[k.M 6& iRFkj dh fpukbZ


LABOURS ON DRESSED STONE & Contd..

rjk'k gq;s iRFkj ij Je ewY; & tkjh


PER SQUARE METRE

Granite or
trap stone

Lime stone or
sand stone

xzSukbV ;k

pwuk ;k cyqvk
iRFkj

06089 Hammer dressing with maximum ca/kqvk iRFkj


depression from a straight edge
Rs.
held against the surface not
79.30

exceeding 40mm dressing

06090 Ditto 20mm


119.00

06091 Ditto 6mm


227.40

Rs.
39.70
60.80
113.70

06092 Rough tooled dressing

264.40

132.20

06093 Punched dressing

06094 Close picked dressing

343.70
766.70

171.80
383.30

06095 Fine tooled dressing

793.10

396.60

PER RUNNING METRE


06096 Drafted margin, punched dressed,

25mm wide

76.70

39.70

194.30

97.30

129.50

64.80

64.80

32.20

06100 All as in item 06099, exc. 15mm but

n. exc 50mm wide

156.00

77.70

06101 Ditto, exc 50mm but n. exc.

100mm

259.10

131.90

06102 Drilling holes for bolts, pipes, etc.

n. exc 25mm dia

37.00

18.50

06103 Ditto.exc 25mm but n. exc 60mm

dia

47.60

23.80

06104 Ditto exc 60mm but n. exc 100mm

dia

58.20

29.10

(N exc 100mm in width or girth and close


picked dressed)
06097 Grooves (square, hollowed or

dovetailed), rebate in face work


06098 Grooves for joints, tongues of cills,
etc., throat (or small weather
groove) as for cills, drip courses,

etc. and rebates as for joints


06099 Chamfer, splays or arris in

facework n. exc 15mm wide

EACH (PER 10 CM IN DEPTH)

izfr oxZ ehVj


06089 lh/ks fdukjs ls ysdj lrg ds lkFk 40 feeh
vuf/kd esa Hkkjh ncko ds lkFk /kqjeqV ls
lery izlk/ku
06090 mi;qZDr] 20 feeh
06091 mi;qZDr] 6 feeh
06092 eksVs e'khuh izlk/ku
06093 ikafpr izlk/ku
06094 l?ku BlkBl izlk/ku
06095 eghu e'khuh izlk/ku
izfr ehVj
06096 vk:fir gkf'k;k dh 25 feeh pkSM+h lkafpr
izlk/ku bl ij
100 eheh vuf/kd pkSM+kbZ ;k eksVkbZ rFkk
l?ku BlkBl izlk/ku
06097 [kkaps pkSdksj ;k diksr iqPNh eksgjs dk;Z esa
irke
06098 tksMk+ ]as fly dh thHkksa vkfn daB ;k NksVs ia[kh
tSls fly ds fu;kr jn~ns vkfn rFkk tksMk+ as ds
leku fjfDr;ksa ds fy;s [kkaps fNnz
06099 i[k] frjNs Qyd ;k eksgjs dk;Z esa 15 feeh
vuf/kd pkSM+s mrdks.kZ
06100 lc en 06099 tSlk 15 feeh ls vf/kd
fdUrq 50 feeh ls vuf/kd pkSM+kbZ
06101 mi;qDZ r 50 feeh ls vf/kd fdUrq 100 feeh
vuf/kd
izR;sd eksVkbZ esa izfr 10 lseh
06102 dkoys] uyksa vkfn ds 25 feeh vuf/kd
O;kl ds ojes ls Nsn djuk
06103 mi;qZDr] 25 feeh ls vf/kd 60 feeh
vuf/kd O;kl
06104 mi;qZDr] 60 feeh ls vf/kd 100 feeh
vuf/kd O;kl

94

SECTION 6

SECTION 6 STONE MASONRY

[k.M 6& iRFkj dh fpukbZ


MESCELLANEOUS LABOURS

fofHkUu Je
EACH
06105 Refastening and securing ends of
balusters, newels, rag bolts, etc., let into
stone and grouted in cement mortar
including recutting the mortices and

regrouting in cement mortar

iz R ;s d
06105 taxyksa dh NM+ksa lh/kh pkgs nkarsnkj dkoyksa ds fdukjksa
dks nqckjk dluk cka/kuk iRFkj ds vUnj Mkyuk rFkk
lhesVa elkys dh HkjkbZ djuk f>fj;ksa dh nqckjk dVkbZ
o lhesaV elkys dh HkjkbZ lfgr

Rs.

53.70

STONE KERBS

fdukjs mikar dk iRFkj


d izR;sd iRFkj yEckbZ esa 45 lseh ls de ugha gksxk flok; tgka
ca/kd ds :i esa ;k o esa vko';d gksA
(b) Not more than half the depth of each stone shall be burried [k izR;sd iRFkj dk vk/ks ls vf/kd Hkkx tehu esa ugha nck;k
in ground.
tk,sxkA
(c) Kerb stones of sizes other than those specified below shall x uhps fn;s x;s fufnZ"V ls fHkUu fdukjs ds iRFkj dh ykxr
be priced prorata.
;Fkkuqikr vkadh tk;sxhA
(a) Each stone shall not be less than 45 cm in length except
where required as closer or on curve.

PER RUNNING METRE

06106 Stone kerb of roughly squared


stones of size 20cm x 30cm,
dressed so that the maximum
depression from a straight
edge held against the dressed
surface shall not exceed 6mm
for top and exposed surfaces
of sides and 20mm for the rest
of surfaces jointed in cement

mortar 1:6 and struck flush

Granite or trap
stone
xSzukbV ;k ca/kqvk
iRFkj

Lime or sand
stone
pwuk ;k cyqvk
iRFkj

M&L
lkexazh
o Je

Except
dressed
stone
Rkjkks iRFkj
jfgr

M&L
lkexazh
o Je

Except
dressed
stone
rjkks
iRFkj
jfgr

Rs.

Rs.

Rs.

Rs.

441.70

97.10

288.90

97.10

06107Ditto but of size 15cmx30cm

375.40

58.40

231.70

58.40

06108 Stone kerb of roughly squared


stones of size 20cm x 30cm, all
surfaces hammer dressed so
that the maximum depression
from a straight edge held
against the dressed surface
shall not exceed 20mm jointed
in cement mortar 1:6 and

struck flush

325.30

81.80

225.50

81.20

256.40

134.80

173.60

134.80

06109Ditto, but of size 15cm x

30cm

iz f r ehVj

06106 eksVs rkSj ij pkSdksj fd;s 20 30


lseh ds mikar dcZ iRFkjksa dks ,sls
laokjk x;k gks tks laokjh xbZ lrg
ds fdukjksa ds lkFk ncko lrg ds
ij o fn[kus okys fdukjksa esa 6
feeh rFkk 'ks"k lrg esa 20 lseh ls
vf/kd u gksa mUgsa 1%6 ds lhesaV
elkys ls tksMd
+ j likV lajpuk
mi;qDZ r] fdUrq 15 30 lseh- uki ds
06108 eksVs rkSj ij pkSdksj fd;s x;s 20
30 lseh ds mikar iRFkjksa dh iwjh
lrg gFkksM+s ls ,slh laokjh xbZ gks
fd laojh lrg ds fdukjs ds lkFk
ncko 20 feeh ls vf/kd u gks rFkk
mUgsa 1%6 ds lheaVs elkys ls tksMd
+ j
likV lajpuk
06107

06109 mi;qZDr] fdUrq 15 30 lseh uki

95

SECTION 6

SECTION 6 STONE MASONRY

[k.M 6& iRFkj dh fpukbZ


VENEERING TO WALLS, FIREPLACES, PILLARS, STEPS ETC.

nhokjksa] vaxhfB;ksa] [kEHkksa] lhf<+;ksa vkfn ij ijr vkoj.k yxkuk


(a) Screed shall be measured separately under Section
14 Plastering and Pointing.

d ioZ] ijr izFkd :i ls [kaM 14& iyLrj o Vhi dk;Z ds


vUrxZr ekih tk;sxhA

(b) In case of radially dressed or circular slabs, the dimensions


of the circumscribing rectangle of the dressed slabs used in
the work shall be measured.

[k f=T;kRed rjk'ks x;s ;k xksykdkj ifV;ksa ds ekeys esa dk;Z esa


iz;qDr rjk'ks iRFkj ds ifjlheu vk;r ds ifjeki dks ekik
tk;sxkA
x [kijs Vkby izFkd ekis tk;saxsA

(c)

Tiles shall be measured separately.

izfr oxZ ehVj

PER SQUARE METRE


06110 Dholpur stone with hammer
dressed facework (with maximum
depression from a straight edge
held against the dressed surface
not exc 20mm), about 40mm high,
75mm deep in straight courses, laid
and jointed in cement and stone
dust mortar 1:3, recess pointed
(10mm x 20mm) with an admixture
of white cement and Dholpur stone

dust 1:1
06111 40mm thick sand stone slabs,
dressed close picked on exposed
faces, set and jointed in cement and
stone dust mortar 1:3 and pointed
in cement mixed with approved

pigment to match
06112 40mm thick sand stone slabs
polished, set and jointed in cement
and stone dust mortar 1:3 and
pointed in cement mixed with

approved pigment to match


06113 40mm thick lime stone slabs/ tiles,

polished ditto

M&L

Except stone

lkexzh o Je

iRFkj jfgr

Rs.

Rs.

978.20

772.10

723.90

1062.30

1014.40

581.80

920.20

920.20

06110 gFkksM+s ls rjk'ks /kksyiqjh iRFkj dks eksgjs


dk;Z esa lh/ks fdukjs ls likV lrg esa
vf/kdre ncko 20 feeh ls vf/kd u gks
rdjhou 40 feeh apk] 75 feeh xgjkbZ
esa lh/kh pky esa 1%3 ds lhesV o izLrj
pwjk es yxkuk o tksM+uk] rFkk 1%1 ds
lQsn lhesaV o /kksyiqjh iRFkj pwjs ds
feykos ls f>fj;ksa 10 20 feeh esa Vhi
djuk
06111 ckgjh rjQ 40 feeh eksVs cyqvk iRFkjksa
dks rjk'kdj Bksl lVkrs gq, 1%3 ds lhesVa
o izLrj pwjs esa yxkuk o tksM+uk rFkk
feyrs gq;s lhesaV feys jaxhu nzO; ls Vhi
djuk
06112 40 feeh eksVs ikfyl fd;s cyqvk iRFkjksa
dks 1%3 ds lhesaV o izLrj pwjs ds elkys
ls yxkuk o tksMu+ k rFkk feyrs gq;s lhesVa
feys jaxhu nzO; ls Vhi djuk
06113 40 feeh eksVs pwuk iRFkj ifV;k@[kiMs]
ikfyl fd;s gq,] mi;qZDr

96

SECTION 6

SECTION 6 STONE MASONRY

[k.M 6& iRFkj dh fpukbZ


DHOLPUR STONE CLADDING
S&F
06114 Dholpur
stone
cladding gang saw cut 16 to 18mm
25 to 30mm
Rs.
Rs.
with machine cut
edges, uniform colour
of each stone size
exceeding 0.5 sqm
area fixed with and
including one number
SS clamps (grade 202) of flat-30mm X
2mm, 150mm long
made to shape in each
slab, making V groove
at top and bottom of
stone and drilling
hole for hold fastener,
polishing, rubbing &
including silicon
1295.00
treatment.
1661.50

06115 Dholpur
stone
cladding gang saw
cut with machine cut
edges,
uniform
colour of each stone
size exceeding 0.25
sqm area and not
exceeding 0.5 sqm
fixed with and
including
one
number SS clamps
(grade -202) of flat
30mm
X
2mm,
150mm long made to
shape in each slab,
making V groove at
top and bottom of
stone and drilling
hole for hold fastener,
polishing, rubbing &
including silicon
1183.20
treatment

1420.60

Except Stone
16 to 18mm
Rs.

25 to 30mm
Rs.

692.80

831.70

764.30

880.10

97

SECTION 6

SECTION 6 STONE MASONRY

[k.M 6& iRFkj dh fpukbZ


DHOLPUR STONE CLADDING
06116 Dholpur
stone
S&F
cladding gang saw 16 to 18mm
25 to 30mm
cut with machine cut
Rs.
Rs.
edges,
uniform
colour of each stone
size not exceeding
0.25 sqm fixed with
and
including,
making V groove at
top and bottom of
stone and drilling
hole for hold fastener,
polishing, rubbing &
including silicon
treatment.
834.40
994.60

Except Stone
16 to 18mm

25 to 30mm

Rs.

Rs.

530.40

623.00

MARBLE WORK

laxejej ds dk;Z
(a) Screed shall be measured separately under Section
14Plastering and Pointing.
(b) In case of radially dressed or circular slabs, the dimensions
of the circumscribing rectangle of the dressed slabs used in
the work shall be measured.
(c) Tiles shall be measured separately.

d ijr ih izFkd [kaM 14& iyLrj o Vhi dk;Z esa ekih tk;sxhA
[k ekuqlkj rjk'kh o xksykdkj ifV;ksa ds dk;Z esa iz;Dq r ifjlheu
vk;r ds ifjeki dks ekik tk;sxkA
x Vkbysa izFkd ekih tk;saxhA

PER SQUARE METRE

M&L

Except stone

06117 Marble work 18 to 20mm thick


(table rubbed and polished) in
steps, jambs, pillars, windowcills,
cooking platforms and like in
cement mortar (1:4) including
pointing in white cement (1:2) using
marble dust with admixture of
pigment to match with marble
shade of following types

lkexzh o Je

iRFkj jfgr

Rs.

Rs.

(a) Makrana white

2739.60

974.90

(b) Abu plain

1820.90

931.70

(c) Makrana doogri

1804.70

931.70

(d) Makrana Adanga

2044.30

931.70

izfr oxZ ehVj


06117 18 ls 20 feeh eksVkbZ esa laxejej dk;Z
fpduh f?klkbZ o ikfyl dh gqbZ lhf<+;ks]a
dfM+;ksa] [kaHkksa] f[kM+dh] flyksa ij 1%4
lhesaV elkys esa 1%2 lQsn lhesaV esa
laxejej dh Nkuu dks laxejej jaxr
ls feykrs gq;s jatd nzO; feykos ls Vhi
dk;Z lfgr
d lQsn edjkuk
[k lknk vkcw
x edjkuk Mwxjh
?k edjkuk vMaxk

98

SECTION 6

SECTION 6 STONE MASONRY

[k.M 6& iRFkj dh fpukbZ


MARBLE WORK Contd...

laxejej ds dk;Z& tkjh


PER SQUARE METRE

M&L

Except stone

06118 Ditto, as item 06117 but black


marble of following types

(a) Bhaislana Zebra

(b) Chitter black

(c) Abu Zebra

lkexzh o Je

iRFkj jfgr

Rs.

Rs.

2298.10

931.70

1777.70

931.70

1770.70

931.70

2183.40

931.70

06119 Ditto, as item 06117 but marble of


any shade other than white and

black
06120 Marble work (table rubbed and
polished) for wall lining
(veneering to wall) 25mm thick in
cement mortar (1:3) and pointing
with white cement (1:2) using
marble dust with admixture of
pigment to match with shade of
following types

(a) Makrana White

izfr oxZ ehVj


06118 mi;qZDr] en 06117 tSlk fdUrq fuEu
izdkj dh dkyh laxejej
d /kkjhnkj HkSl
a ykuk
[k fpRrhnkj dkyh
x /kkjhnkj vkcw
06119 mi;qDZ r] en 06117 tSlk fdUrq laxejej
dkyh o lQsn ls fHkUu jaxr esa
06120 laxejej dk;Z fpduh f?klkbZ o ikfyl
dh gqbZ 25 feeh eksVkbZ esa nhokj fdukjh
ds fy;s nhokj iz"B vkoj.k lhesVa 1%3
esa rFkk fuEu jaxr ls feyrs jaxhu ?kksy
esa lQsn lhesaV 1%2 o laxejej Nkul
feykdj Vhi djus lfgr

2748.00

944.10

(b) Abu white


(c) Abu Pantha

1786.10

931.70

1786.10

940.10

(d) Makrana chak Doogri


(e) Makrana Adanga

1786.10

940.10

2052.70

940.10

d
[k
x
?k
M

lQsn edjkuk
lQsn vkcw
fpRrhnkj vkcw
edjkuk pd Mwxjh
edjkuk vM+aXkk

GRANITE WORK

xzsukbV ds dk;Z
(a) Screed shall be measured separately under Section
14Plastering and Pointing.
(b) In case of radially dressed or circular slabs, the dimensions
of the circumscribing rectangle of the dressed slabs used in
the work shall be measured.
(c) Tiles shall be measured separately.

d ijr ih izFkd [kaM 14 iyLrj o Vhi dk;Z esa ekih tk;sxhA


[k ekuqlkj rjk'kh o xksykdkj ifV;ksa ds dk;Z esa iz;Dq r ifjlheu
vk;r ds ifjeki dks ekik tk;sxkA
x Vkbysa izFkd ekih tk;saxhA

PER SQUARE METRE


06121Granite (of any type) work
(table rubbed and polished)
in steps, jambs, pillars, window-cills, cooking platforms and like in cement
mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match

with shade of granite.

izfr oxZ ehVj


M&L

lk o Je

Except stone

iRFkj jfgr

20mm
thick

25mm
thick

Rs.

Rs.

Rs.

2870.40

3258.20

931.70

20 fe eh 25 fe eh
eksVkbZ
eksVkbZ

06121 xzsukbV fdlh Hkh izdkj dk dk;Z


fpduh f?klkbZ o ikfyl dh gqbZ
lhf<+;ks]a dfM+;ks]a [kaHkks]a f[kM+dh] flyks]a
idkus ds IysVQkeZ vkSj mlh tSls
1%4 lhesaV elkys esa 1%2 lQsn
lhesaV esa laxejej dh Nkuu dks
xzsukbV jaxr ls feykrs gq;s jatd
nzO; feykos ls Vhi dk;Z lfgr

99

SECTION 6

SECTION 6 STONE MASONRY

[k.M 6& iRFkj dh fpukbZ


GRANITE WORK Contd...

xzsukbV ds dk;Z&tkjh
PER SQUARE METRE
06122 Granite (of any type) work
(table
rubbed
and
polished) for wall lining
(veneering to wall) 12mm
thick in cement mortar
(1:3) and pointing with
white cement (1:2) using
marble dust
with
admixture of pigment to
match with shade of

granite.

izfr oxZ ehVj


M&L

lk o Je

20mm
thick

25mm
thick

Rs.

Rs.

06122 xszukbV fdlh Hkh izdkj dk dk;Z


fpduh f?klkbZ o ikfyl dh gqbZ 12
feeh eksVkbZ esa nhokj fdukjh ds fy,
nhokj iz"B vkoj.k lhesaV 1%3 esa
rFkk xzsukbV jaxr ls feyrs jaxhu
?kksy esa lQsn lhesVa 1%2 o laxejej
Nkul feykdj Vhi djus lfgr

Except stone

iRFkj jfgr

20 fe eh 25 fe eh
eksVkbZ
eksVkbZ
Rs.

940.10

2608.90

MATERIALS (Supplied Only)

lkexzh dsoy vkiwfrZ


BUILDING STONE, ETC.

fuekZ.k ds iRFkj vkfn


The rates include for stacking in regular heaps for measurement.

bu njksa esa lkexzh dks eki ds fy;s pV`Vksa esa yxkuk kfey gSA
izfr ?ku ehVj

PER CUBIC METRE


Rs.

vuqeksfnr [knkuksa dk vux<+ iRFkj%&

587.50

06124 For random and polygonal rubble


walling, excluding bond/through

stones
06125 For bond/through stones as

specified

599.20

06123 gkFk HkjkbZ ds fy;s


06124 vleku o cgqeq[kh vux<+ nhokjxhjh ds
fy;s] pky@vkjikj iRFkj jfgr

RUBBLE STONE FROM APPROVED


QUARRIES:06123 For hand packing

06126 Roughly squared rubble stone


including bond/through stones

06125 pky@vkjikj iRFkj tSlk fufnZ"V gks


705.00
705.00

06126 eksVs rkSj ij pkSdksj fd;k vux<+ iRFkj]


pky@vkjikj iRFkj lfgr

BOULDERS (Quarried or river bed)

fkyk[ka M [knkuh ;k unhryh;


PER CUBIC METRE
06127 Boulders 7cm to 15cm dia

06128 Boulders exceeding 15cm and upto

30cm dia

Rs.
470.00
411.20

izfr ?ku ehVj


06127 f'kyk[kaM 5 lseh ls 15 lseh O;kl ds
06128 f'kyk[ka M 15 ls e h ls vf/kd o 30 ls e h
O;kl rd ds

100

SECTION 6

SECTION 6 STONE MASONRY

[k.M 6& iRFkj dh fpukbZ


STONE FOR DRESSED STONE WORK

izlkf/kr iRFkj ds dk;Z ds fy;s iRFkj


Granite or Lime or sand
trap stone stone

PER CUBIC METRE


STONE IN BLOCK, ROUGHLY
SQUARED, FOR DRESSED STONE
WORK
06129 Of the dimension ordered, quarry
scabbled, n exc l m in length or60

dm3 in volume per block


06130 Ditto exc. lm but n exc 2m in length or
exc 60 dm3 but n exc 180 dm3 ditto

xzSukbV ;k pwuk ;k
ca/kd iRFkj cyqvk iRFkj
Rs.

Rs.

705.00

646.20

728.50

587.50

izfr ?ku ehVj


eksVs rkSj ij pkSdksj] izlkf/kr dk;Z
dh iRFkj ifV;ka
06129 funsfZ 'kr ifjeki dh [knku ls fudyh
yEckbZ esa 1 eh vuf/kd ;k ?ksjs esa 60
Ms eh3 izfr ifV;k
06130 mi;qZDr 1 eh ls vf/kd fdUrq 2 eh
vuf/kd yEcs ;k 60 ls vf/kd fdUrq
180 Ms eh3 vuf/kd] mi;qZDr
izfr oxZ ehVj

PER SQUARE METRE


Rs.

06131 Jodhpur stone for lintels, beams and


roofs, self faced, 7.5 to 10cm thick

411.20

06132 Ditto 10 to 12.5cm thick

470.00

06131 fyaVy] /kju o Nkksa ds fy;s Lo;a jfpr


tks/kiqjh iRFkj] 7-5 ls 10 lseh eksVs
06132 mi;qZDr] 10 ls 12-5 lseh eksVs

101

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7& ydM+h dk;Z c<+bZxhjh
SPECIAL CONDITIONS
foksk krsZ
7.1 Measurements
(a) The following method of measurement shall be
followed:
(1) Lengths shall be measured to the nearest
centimetre.
(2) Width of surface formed by two or more boards
shall be measured to the nearest centimetre.
(3) Width of single or detached boards and thickness of
all boarding shall be measured to the nearest 2 mm.

7-1 eki
d eki ds fy;s uhps fn;k x;k rjhdk viuk;k tk;sxk%
1 yEckb;ka fudVre lsUVhehVj rd ekih tk;saxhA
2 nks ;k nks ls vf/kd Qyd ls cuh lrg dh pkSM+kbZ
fudVre lsaVhehVj rd ekih tk;sxhA
3 ,dy ;k vyx yxs Qydksa dh pkSMk+ bZ rFkk reke r[rscna h
dh eksVkbZ fudVre 2 feeh rd ekih tk;sxhA
4 QfV~V;ks]a okks]a ifV~V;ksa rFkk leku phtksa dks vuqiLz Fk dkV
ifjeki esa fudVre 2 feeh rd ekik tk;sxkA

(4) Scantlings, battens, fillets and the like shall be


measured to the nearest 2mm in cross sectional
dimensions.
(5) Sections of scantlings, battens, fillets, etc. shall
be measured as the least rectangle or triangle from
which the section can be obtained.
(6) In the case of scantlings, battens, fillets etc. with
a varying section, the largest section, shall be
measured.
(7) Mitred pieces shall be measured along their
longest length.
(8) In measuring framed timber, the length of tenons
and scarfs shall be added to the sight length of
the framed member. Extra length where required
to be embedded in walls and floors shall be added
to the sight length.
(b) Small items such as purlin cleat/bracket to support
truss/wall plate/part of truss member in case of nail
trusses/wooden gusset plate and like item shall be
paid under appropriate item such as scantling/
boarding/fillet/batten as the case may be, such items
shall not be paid under Section 8 (Joiner work).

8 Qjesnkj ydM+h dh eki es]a pwy o dafB;ksa dks <kapns kj vax


dh n'kZ yEckbZ esa tksM+k tk;sxkA nhokjksa Q'kksZ esa tgka
vfrfjDr yEckbZ var% LFkkfir visf{kr gks rks og n'kZ
yEckbZ esa ekih tk;sxhA
[k NksVh phts]a tSls dSp
a h MV~V@
s nhokj IysV@dSp
a h [kaM ds vax dSp
a h
/kju dh dhyksa dSp
a h voyach cSfz dV@dSp
a h@ydM+h dh laxe
iV~Vh rFkk leku phtksa dk Hkxqrku mi;qDr enksa ds varxZr gksxk
tSls QfV~V;ka@r[rscna h@ckks@
a ifV~V;k tSlk Hkh ekeyk gks ,slk
phtksa dk Hkqxrku [kaM 8 la;kstu dk;Z ds varxZr ugha gksxkA

7.2 Rates
(a) Unless specifically mentioned to the contrary, the
S.S.R. rates for carpenters work (materials and labour
or laying or fixing only) include for nails, spikes, bording for and fixing of bolts, etc. Bolts, nuts and
washers shall be paid for as Supplied only without
any deduction for the value of the nails displaced.
(b) The rates for wrought scantling, boarding, battens,
fillets, etc. include for taking off small arise not exc
3mm wide, when required.
(c) The rates for shoring timbers include for every description of shoring, except to excavations. Cutting
into walls for needle shores, etc. shall be paid for extra.

7-2 njs a
d tc rd fd fo'ks"k:i ls foijhr u dgk x;k gks c<+bx
Z hjh ds fy;s
,l ,l vkj dh njksa lkexzh o Je ;k fcNkuk ;k LFkkiu dsoy
esa dhyks]a dkaVks]a dkoyks]a vkfn ds fy;s Nsn djuk o yxkuk vkfn
kkfey gSA dkoyks]a f<ofj;ksa o ok'kjksa dk Hkqxrku] fcuk fudkyh xbZ
dhyksa dh ykxr dh dVkSrh ds] ^dsoy vkiwfkZ* esa fd;k tk;sxkA
[k cuh cukbZ QfV~V;ka] r[rs canh] ifV~V;ka] oks vkfn dh njksa esas
3 feeh vuf/kd pkSM+s NksVs mHkkj] tc visf{kr gksa] fudkyuk
'kkfey gSaA
x ydM+h dh rVcanh dh njksa es]a [kqnkbZ ds vkykok lHkh izdkj dh
rVcanh 'kkfey gSA lwfpdk rV ds fy;s nhokjksa esa dVkbZ vkfn
ds fy;s vfrfjDr Hkqxrku gksxkA

5 QfV~V;ksa] okksa] ifV~V;ksa vkfn dh dkV dh eki ml lcls


NksVs vk;rkdkj ;k f=Hkqth esa gksxh ftleas ls dkV izkIr dh
tk ldrh gSA
6 ifjorhZ dkV dh QfV~V;ks]a ifV~V;ks]a okkssa vkfn ds ekeys esa
lcls yEch dkV dks ekik tk;sxkA
7 dks.kh; [kaM] mudh lcls yEch yEckbZ rd ekis tk;saxsA

102

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7 ydM+h dk;Z c<+bZxhjh
SPECIAL CONDITIONS -Contd....
foksk krsZa - tkjh
(d) The rates for laying only or fixing only include for the
labour required to fit and fix the prepared material in
the work and are exclusive of timber and fabrication
but include jointing materials such as nails, glue, pins,
etc. The rates for except timber, and labour only
include in addition for all fabrication and preparation
of the materials, etc. except the supply of clean sawn
timber in required sections.
(e) Where no specific provision for extra payment for
curved or circular work is made, the following method
shall be adopted:
In superficial work circular on plan or elevation (e.g. in
shutters, partitions, framing, etc.) the circular portions
shall be measured square separately from the straight
portions and priced at twice the rates for straight work.
(f) The rates against items in repairs include for removing old and decayed timber, carrying it to store where
directed and preparing the adjacent work to receive
the new work.

?k ^^dsoy fcNkuk** ;k ^^dsoy LFkkiuk** dh njksa esa] cukbZ gqbZ


lkexzh dks dk;Z esa fcBkus o yxkus dk Je rFkk ydM+h o jpuk
dks NksM+ dj tksM+us dh lkexzh tSls dhysa] ljsl] es[ksa vkfn
'kkfey gSA ydM+h jfgr o dsoy Je dh njksa esa flok;
visf{kr dkV dh ydM+h dh vkiwfrZ ds vkSj lHkh dk;ksZa ds lkFk
lkexzh vkfn dh lajpuk o lTtk Hkh kkfey gSA
M+ tgka o ;k xksykdkj dk;Z ds fy;s vfrfjDr Hkqxrku dk fo'ks"k
izko/kku ugha fd;k x;k gS ogka fuEu rjhdk viuk;k tk;sxk%&

7.3 Adjustment of rates

7-3 njksa dk lkeatL;


7-3-1 bl [kaM esa njsa] f}rh; Js.kh dh uje ydM+h o dBksj ydM+h
ds fy;ss nh xbZ gSaA
7-3-2 tc dk;Z fHkUu Js.kh dh ydM+h ls fu"ikfnr gks] rks ,slh ydM+h
ds fy;s njsa fuEu rkfydk esa nh xbZ fof/k vuqlkj fu/kkZfjr dh
tk;sxhA fopkjk/khu dk;Z ds fy;s fdlh Hkh vU; fof/k ls izkIr
njksa ij ;g fof/k ojh;rk ysxh%&

7.3.1 Rates in this Section are given for second class softwood and hardwood.
7.3.2 When work is executed in a different class of timber,
the rates for such timber shall be derived as given in
the following table. This method shall take precedence over any other method of deriving rates for
the work in question.
For work M&L (or
in
S&F)
rates

Except timber Material supor fixing only plied only


or Laying
rates
only rates

1
2
1st class Add 65%
softwood to M&L
or S&F
rates of
2nd class
softwood

3
Rates of 2nd
class soft wood
shall apply
with out any
addition

4
Add 70% to
supplied only
rates of 2nd
class softwood

1st class Add 75% to


hardM&L or
wood
S&F rates
of 2nd class
hardwood

Rates of 2nd
class hard
wood
shall apply
without any
addition

Add 80% to
supplied only
rates of 2nd
class hardwood

7.3.3 Rates for ballies are for any class of soft or hard wood
and the above adjustment is not applicable to these.

vk;kstu ij lrgh ;k mRFkkiu dk;Z esa tSlk 'kVjks]a foHkktuksa


Qjescna h vkfn esa xksykdkj Hkkxksa dks lh/ks Hkkxksa ls vyx oxhZdr`
ekik tk;sxk ,oa mldk Hkqxrku lh/ks dk;Z ls nqxuh njksa ij gksxkA
p ^^ejEer es*a * dh njksa ds v/khu] iqjkuh o {kh.k ydM+h gVkuk] tgka
dgk tk; ogka ys tkdj tek djuk rFkk lkFk dzs dk;Z dks u;k
dk;Z xzg.k djus ds fy;s laokjuk 'kkfey gSA

var%dk;Z gsrq

izFke Js.kh
uje ydM+h

**lkexzh o Je**
;k vkiwfrZ o
LFkkiu njsa
2

**ydM+h jfgr** ;k lkexzh ^^dsoy


^^dsoy LFkkiu** vkiwfrZ** njsa
;k ^^dsoy
fcNkuk** njsa
3

tksM+sa 65%
f}rh; Js.kh dh
uje ydM+h dh
^lkexzh o Je*
;k ^vkiwfrZ o
LFkkiu*

f}rh; Js.kh dh
uje ydM+h dh
njsa fcuk dqN Hkh
tek fd;s ykxw
gkasxh

tksM+sa 70%
f}rh; Js.kh
dh uje
ydM+h dh
^dsoy vkiwfrZ*
njksa esa

izFke Js.kh
tksM+sa 75%
dBksj ydM+h f}rh; Js.kh dh
dBksj ydM+h dh
^lkexzh o Je*
;k ^vkiwfrZ o
LFkkiu* njksa esa

f}rh; Js.kh dh
dBksj ydM+h dh
njsa fcuk dqN Hkh
tek fd;s ykxw
gkasxh

tksM+sa 80%
f}rh; Js.kh
dh dBksj
ydM+h dh
^^vkiwfrZ dsoy**
njksa esa

7-3-3 cfYy;ksa dh njs]a uje ;k dBksj fdlh Hkh Js.kh ds fy;s gSa rFkk
mij dk lkeatL; cfYy;ksa ij ykxw ugha gksxkA

103

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7 ydM+h dk;Z c<+bZxhjh
SPECIAL CONDITIONS -Contd....
foksk krsZ -tkjh
7.3.4 Rates for shoring and strutting, centering and formwork are for any type of timber, softwood or hardwood and of any class and the above adjustment is
not applicable to these.

7-3-4 rVcanh o Vsdcanh] <wyk canh o Qjekcanh dh njsa fdlh Hkh


izdkj dh uje ;k dBksj rFkk fdlh Hkh Js.kh dh ydM+h ds fy;s
gSa] rFkk bu ij ij dk lkeatL; ykxw ugha gksxkA

SHORING AND STRUTTING


rVcanh ,oa Vsdcanh

rVcanh ,oa Vsdcanh dh njksa esa ydM+h dk iz;ks x o Nhtu 'kkfey gS(
lkFk j[kuk] fuekZ.k djuk] <wyk mrkjuk o lHkh vko';d dkoyksa ds
lkFk gVkuk muds Nsn djuk lfgr dqkk idM+ ifk;ka] dkaV]as dhy]
QUuh vkfn lfgr laiw.kZ djuk rFkk tc rd t:jr u gks rc rd
LFkkiu esa yxk;s j[kuk 'kkfey gSA
izfr ?ku ehVj
Rs.
07001 ydfM+;kss dh rVcanh o Vsdcanh

The items for shoring and strutting include use and waste of
timber; putting together, erecting, striking and removing
together with all necessary bolts (including boring holes for
same), dogs clamps, spikes, nails, wedges, etc. complete and
maintaining in position until no longer required.
PER CUBIC METRE

07001 Shoring and strutting timbers

3145.50

CENTERING TO ARCHES
egjkoksa MkVksa dh <wykcanh
(a)

(b)

(c)

The items for centering include use and waste of


timber, putting together, erecting, striking and
removing, together with all necessary bolts
(including boring holes for same), dog clamps,
spikes, nails, wedges, etc. complete and maintaining
in position until no longer required.
The items also include for all supports, struts,
wedges, braces, bolts, etc. necessary for the proper
strength and rigidity of the centering and form work.
The measurement of centering shall be the actual
area of soffit supported.
PER SQUARE METRE

d <wykcanh dh njksa esa ydM+h dk iz;ksx o Nhtu] LkkFk j[kuk] [kM+k


djuk] mrkjuk o lHkh t:jh dkoys buesa Nsn djus lfgr
gVkuk RkFkk] dqkk ikh] dkaV]s dhy] QUuh vkfn lfgr iwjk djuk
rFkk LFkkiu esas rc rd j[kuk tc rd fd t:jr u jgsA
[k bu njksa esa lHkh lgkjs] Vsd]a s QfUU;ka] cjek] dkoys vkfn tks <wyk o
Qjekcanh dh vPNh etcwrh o dM+kbZ ds fy;s vko';d gS]a 'kkfey gSAa
x <wykcanh dh eki] v/k%Lry vk/kkj dk okLrfod {ks= gksxhA
izfr oxZ ehVj

Rs.

07002 Centering to brick, stone or concrete block arches

of any shape, not exceeding 6 metres span

725.70

07003 Ditto exceeding 6m but not exc 12m span

725.90

07002 6 ehVj vuf/kd ?ksjs dh fdlh vkd`fr dh bZVa ] iRFkj


;k dahV dh esgjkoksa dh <wykcanh
07003 mi;qZDr] 6 eh ls vf/kd fdUrq 12 eh vuf/kd ikV

FORMWORK TO CONCRETE ETC.


dahV vkfn esa Qjekcanh
(a) The measurement of formwork shall be the actual d Qjekcanh esa eki ml okLrfod lrg dh gksxh] tks dahV]
surface in contact with concrete, reinforced brickwork,
izofyr bZaV dk;Z vkfn ftlds fy;s Qjekcanh visf{kr gS] ds
etc. requiring formwork.
lkFk layXu gSA
(b) The rates for formwork include :
[k Qjekcanh dh njksa esa 'kkfey gS%&
(1) Use and waste of timber, putting together,
1 ydM+h dk iz;skx o Nhtu] lkFk j[kuk] [kM+k djuk]
erecting, striking and removal and maintaining
mrkjuk o gVkuk rFkk tc t:jr u gks rc rd LFkkiu
in position until no longer required;
es j[kukA

104

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7 ydM+h dk;Z c<+bZxhjh
FORMWORK TO CONCRETE ETC.-Contd....
dahV vkfn esa Qjekcanh - tkjh
(2) Splayed edges, notchings, allowance for overlaps
and passings at angles, battens, strutting, bolting,
nailing, wedging, easing etc.;
(3) All supports, struts, braces, wedges as well as
mud cills, Piles or other suitable arrangements to
support the formwork;
(4) Bolts, wire ties, clamps, spreaders, etc. to hold the
sheathing together;
(5) Working scaffolds, ladders, gangways etc.;
(6) Filleting to form stop-chamfered edges or internal
or external splayed rounded angles or grooves
for forming throating not exceeding 25mm wide;
(7) Temporary openings, if required, in the forms for
pouring concrete, inserting vibrators, and
cleaning holes for removing rubbish from the
interior of the sheathing before pouring concrete;
(8) Dressing with oil, white-wash, soft soap or other
approved substance to prevent adhesion;
(9) Raking or circular cutting;

2 frjNs fdukjs] [kkaps cukuk] lfj;ksa ij vfrNknu o vfrfjDr


Nknu dk cV~Vk] ofYy;ka] Vsd
a ] lgkjs] dkoys yxkuk] dhy
yxkuk] QUuh yxkuk] <hyk djuk vkfnA
3 ca/kkbZ dks Fkkes j[kus ds fy;s dkoys] rkj xqPNh] ifk;ka]
izlkjdA
4
5 dk;Zjr epku] lhf<+;ka lewgiFk vkfnA
6 i[knkj fdukjs ca/kkbZ ds Qhrs ;k vUnj ;k ckgj ca/kkbZ ds
<yoka@xksy lfj;s ;k mijks/ku ds fy;s 25 feeh vuf/kd
pkSM+kbZ ds [kkapsA
7 ;fn vko';d gkss rks Qjesa eas dahV Hkjus] dafir Mkyus
ds fy;s] vLFkkbZ fooj fudkyuk RkFkk dahV Hkjus ls igys
c/kkabZ esa ls dwM+k fudkyus ds fy;s Nsnksa dks lkQ djuk

8 fpifpikgV jksdus ds fy;s] rsy] lQsnh] uje lkcqu vU;


Lohd`r nzO; ls laokjukA
9 [kqjpuk ;k xksy dVkbZA
(c) No deduction shall be made for openings upto 0.4 x 0-4 oeh rd ds fooj ds fy;s dksbZ dVkSrh ugha gksxhA
square metre.
(d) Formwork to different parts of a structure shall be
measured under items as applicable.
(e) Formwork to secondary beam shall be measured upto
the sides of main beams but no deduction shall be
made from the formwork of the main beam where the
secondary beam intersects it. No deduction shall be
made from the formwork to stanchion or column
casings at intersections of beam.
(f) Rates for formwork are for timber formwork.
Alternatively the contractor may provide formwork of
plywood, timber with steel sheet lining or steel plate
stiffened with steel angles, steel pipe scaffolding
(telescopic or otherwise), without any price adjustment.
(g) Rough finished surface of concrete shall be the surface
which is not finished fair inside the forms and is
indicated to be plastered or otherwise finished.

?k fuekZ.k ds fHkUu Hkkxksa dh Qjekcanh] ml ij ykxw lacaf/kr en


ds vUrxZr ekih tk;sxhA
M+ lgk;d /kju dh Qjekcanh dks eq[;/kju dh Hkqtk rd ekih
tk;sxh fdUrq tgka lgk;d /kju dkVrk gS ogka eq[; /kju dh
Qjekcanh esa ls dVkSrh ugha gksxhA /kju ds izfrNsnu ij Fkwu dh
Qjescanh ;k dkye dh ca/kkbZ esa ls dVkSrh ugha gskxhA
p Qjekcanh dh ;g njsa ydM+h dh Qjekcanh ds fy;s gSAa fodYi ds
:i es]a fcuk fdlh ewY; lek;kstu ds] Bsdns kj IykbZ dh Qjekcanh]
yksgs dh pknj dh fdukjh ds lkFk ydM+h dh ;k yksgs dh lfj;ksa
ls n`<+ dh xbZ yksgs dh IysV dh Qjekcanh dj ldrk gSA

N dahV dh :{k lrg og gksxh ftls Qjes ds vUnj ifj"d`r ugha


fd;k x;k gS rFkk iyLrj djus ;k vU;Fkk ifj"d`r djus dh
vksj bafxr djrh gSA
(h) Fair finished surface of concrete shall be the surface t dahV dh ifjd`r lrg og gksxh ftls Qjekcanh esa gh ifjd`r
which is finished fair in the formwork.
fd;k x;k gSA

105

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7 ydM+h dk;Z c<+bZxhjh
FORMWORK TO CONCRETE ETC.-Contd....
dahV vkfn esa Qjekcanh - tkjh
PER SQUARE METRE
07004 Formwork to sides of concrete
foundations, footings, bases of
columns, raft and raft beams,
sides and soffits (if any) of
foundation and plinth beams;
and similar work; vertical or to

batter

Rough finished
surfaces of
concrete

dahV dh :{k
lrg
Flat

Curved

LikV

Rs.

Rs.

134.20

177.10

07005 Formwork to faces of walls,


retaining walls, abutments,
parapets and staircase railings
and similar work including
attached pillasters, buttresses,
200
etc.; vertical or to batter
07006 Formwork to soffits of suspended
slabs such as roof slabs, floor
slabs, landings and similar work;
not exceeding 200mm thick
211.50
(Horizontal or sloping)

tksMa+s ifjd`r
07004 Qjekcanh uhoks]a inks]a dkye ds vk/kkjks]a jSV
lrg gsrq
o jSV /kjfu;ks]a dahV dh cxyks]a uhoa o
dqlhZ cxyks o /kjfu;ksa ;fn dksbZ rFkk
leku dk;Z [kM+s ;k <yoka rFkk ry /kjfu;ksa
Rs.
esa
25.00

213.40

25.00

252.50

25.00

259.20

25.00

07007 Ditto, exceeding 200mm thick


246.20

07008 Formwork to edges of concrete


flats, breaks in floors, openings
in concrete walls, floors and roofs
and sides of RCC/PCC bands in
walls, horizontal or sloping, and
similar work all exceeding 20cm
wide. (Where RCC/PCC band in
walls, spanning and opening, the
formwork soffit only shall be
paid for under item 07010)
07009 Formwork to chullah hoods, chajjas, troughs and similar items in
cluding edges
07010 Formwork to sides and soffits of
floor or roof beams, beam haunchings, girders, bressummers,
lintels, cantilevers, shelves
including sup- ports, overhangs,
etc. also splays between floors and

beams, etc.
07011 Formwork to staircases with
sloping or stepped soffits
including risers and stringers

(excluding landing)
07012 Formwork to sides and soffits

of arches
07013 Formwork to fins, louvers, fascia

199.70

215.50

izfr oxZ ehVj

Add for fair


finished
surfaces

25.00

256.00

284.50

25.00

203.70

230.90

25.00

224.00

245.80

25.00

330.20

392.10

25.00

258.60

290.20

25.00

07005 Qjekcanh nhokjksa ds eksgjksa /kkjd nhokjksa]


lhek vk/kkjksa] eqaMsjksa o lhf<;ksa dh jsfyaxksa
rFkk leku dk;Z tSls layXu nhokj LrEHkks]a
nhokj iq"rksa vkfn esa [kM+h ;k <yoka dahV

ij
07006 Qjekcanh fuyafcr ifV;ksa ds v/kLryksa tSls
NrifV;ksa] Q'kZ ifV;ksa] lksikuksa rFkk 200
feeh vuf/kd eksVkbZ ds leku dk;ksZa likV

;k <yoka ds fy;s
07007 mi;qDZ r] 200 feeh ls vf/kd eksVkbZ mi;qDZ r
07008 Qjekcanh dk;Z dahV d{kksa ds fdukjksa]
Q'kkZs ds Hkatd] dahV nhokjks]a Q'kksZ o Nrksa
ds fooj] nhokjksa esa vkj lh lh@ih lh lh
ds if;ksa likV ;k <yoka rFkk 20 lseh ls
vf/kd pkSM+s leku dk;ksZ esa dahV ds fy;s
tgka vkj lh lh@ih lh lh nhokj eksM+]
QSyko o fooj gksa ogka dsoy vk/kkj LraHk
dk en 07010 ds vUrxZr Hkqxrku gksxk

07009 Qjekcanh dk;Z pwYgk Vksiksa] NTtksa] /kwi


Nf=;ks]a VksMs+ dkcsy
Z tyfudkl rFkk fdukjksa

lfgr leku dk;ksZ esa


07010 Qjekcanh dk;Z Q'kZ ;k Nr dh ?kjfu;ks]a /
kjuh ds da/ks] xMZj] ikV dM+h fyaVy] izkl]
VkaM]+ izyoa u vkfn o Q'kZ rFkk /kjfu;ksa ds
chp ds [kakps vkfn

07011 Qjekcanh dk;Z <yoka ;k lh<+hnkj v/k%Lry


okyh lhf<+;ksa esa mBkoksa o yfM+;ks lfgr

iknjfgr
07012 Qjekcanh dk;Z esgjkoksa MkVksa ds cktqvksa o uhps
07013 Qjekcanh fQuks fpefu;ksa] ifV~V;ksa o /kwi
vojks/kdksa ds fy;s

106

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7 ydM+h dk;Z c<+bZxhjh
FORMWORK TO CONCRETE ETC.Contd....
dahV vkfn esa Qjekcanh& tkjh
PER SQUARE METRE

Rough finished
surfaces of
concrete

Add for fair


finished
surfaces

:{k dahV
lrg

tksMa+s ifjd`r
lrg gsrq

izfr oxZ ehVj

Square,
Circular
rectangular on plan
or polyg- vk;kstu
onal
ij

pkSdksj] vk;r xksykdkj


;k cgqHkqth

07014 Formwork to sides of pillars,


Rs.
posts, struts, piers, columns
241.10
and stanchions
07015 Formwork to spiral staircase
with sloping or stepped soffits,
including risers and stringers
273.30
(excluding landing)
07016 Formwork to sides of chimneys
and shafts, vertical or to batter 193.70
07017 Formwork to well steining and
199.80
well curbs

Rs.

Rs.

316.70

25.00

292.10

25.00

215.50

25.00

230.20

25.00

Rough finished
surfaces of
concrete

Add for fair


finished
surfaces

:{k dahV lrg

tksMa+s ifjd`r
lrg gsrq

07014 Qjekcanh dk;Z LrEHkksa] [kaHkksa jksd LrEHkksa]


ik;s LrEHk] dkyeksa] LFkk.kqdksa ds cxy esa

07015 Qjekcanh dk;Z lfiZy lhf<;ka] <yoka ;k


mBkoh iknry mHkkj o iV~Vhnkj ikn
lfgr esa

07016 Qjekcanh dk;Z lh/kh ;k lykeh fpeuh ;k

'kSV dh cktqvksa esa


07017 Qjekcanh dk;Z dq;sa dh nhokjksa o xksy esa

Curved in Curved in
one plane two planes

07018 Formwork to sides and soffits


of domes, vaults, shell roofs

and arch ribs

07019 Formwork to folded plates

,dy o nksgjh o
Rs.
277.70

Rs.
348.00

Rs.
25.00

Rough finished
surfaces of
concrete

Add for fair


finished
surfaces

dahV dh :{k lrg

tksMa+s ifjd`r
lrg gsrq

Rs.

Rs.

183.20

25.00

07018 Qjekcanh dk;Z xqEenks]a rg[kkuks]a nhokj


'khZ"k o esgjkoksa ds fljksa dh cxyksa o ry esa

07019 Qjekcanh oy; IysVksa esa

07020 Formwork to cornices and


mouldings of any shape in
cross section and of any girth

279.00

25.00

07020 Qjekcanh dk;Z dkjfu'kksa o fdlh Hkh vkdkj


o fdlh ?ksjs dh dkjfu'kksa o xksykb;ksa dh

[kM+h dkV esa

107

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7& ydM+h dk;Z c<+bZxhjh
PER RUNNING METRE

Rough finished
surfaces of
concrete

07021 Formwork to edges of concrete


dahV dh :{k lrg
flats, treads, breaks in floors,
window cills, concrete railRs.
ings, openings in concrete
walls, floor and roofs n exc 20
cm wide and sides of RCC/
PCC bands in walls, horizontal or sloping and similar
work exc 10cm but n exc 20cm
40.80

wide
07022 Ditto, exc 5cm but not exc.
19.50

10cm wide
07023 Ditto, not exc 5cm wide
16.10

Add for fair


finished
surfaces

tksMa+s ifjd`r
lrg gsrq
Rs.

3.20
2.90
2.00

iz f r ehVj
07021 Qjekcanh dk;Z dahV d{kks]a ik;nkuksa ds
fdukjks]a Q'kks]Z f[kM+dh dh flys]sa dahV dh
jsfyax] dahV dh nhokjks]a Q'kksZ o Nr ds
Hkatd 20 lseh vuf/kd pkSMs+ focj rFkk
nhokjkssa ds [kM+h ;k <yoka vkj lh lh@ih
lh lh eksM+ rFkk 10 lseh ls vf/kd fdUrq 20
lseh vuf/kd pkSMs+ leku dk;ksZ ds oxy esa

07022 mi;qDZ r] fdUrq 5 lsea h ls vf/kd fdUrq 10

lseh vuf/kd pkSM+s


07023 mi;qZDr] fdUrq 5 lseh vuf/kd pkSM+s

EACH

iz R ;s d

07024 Formwork to small surfaces


such as cantiliver ends, brackets, ends of steps, caps and
bases of pilasters and the col
umns and the like

07024 Qjekcanh dk;Z NksVh lrgsa tSls /kksfM+;ksa


ds Nksj] nhokjfxjh] iknksZ ds Nksj] LrEHk o
[kaHkksa ds 'kh"kZ o vk/kkj rFkk leku dk;ksZ
esa

PER RUNNING METRE


07025 Extra on formwork for filleting to
produce rebates to door frames
etc. including any stops, mitres

etc.
07026 Extra on formwork for filleting to
produce external or internal
splayed, chamfered or bullnosed
angle, exceeding 25 mm width

24.30

2.90

Rs.

iz f r ehVj

22.50

07025 vfrfjDr] [kwaVh] fdjksV vkfn lfgr


njoktksa dh PkkS[kVksa vkfn esa iSrke cukus
ds fy, iV~Vh Cka/kkbZ dh Qjekcanh ij

24.40

07026 vfrfjDr] 25 feeh ls vf/kd pkSMk+ bZ ds


ckgjh ;k vUn:uh] frjNs ;k xksy Qyd
fudkyus ds fy;s Qhrk ca/kkbZ ds fy;s

Qjekcanh dk;Z ij

TIMBER IN SCANTLINGS
ydM+h dh dfM+;ka
(a) The rates for timber fixed apply to scantlings fixed as
girders, lintels, wallplates, joists (except trimmer and
trimming joists, purlins, rafters and carpenters work
generally, which is not framed by means of mortice and
tenon, tusk and tenon or dovetail joints. The rate include
for lapping, halving, tabling, scarfing, notching, birds
mouth cutting, splayed or bevelled ends, boring for and
fixing of bolts, waste, etc. and hoisting and fixing in
position and also for small labours like splaying,
chamfering, rounding angles and nosings not exceeding
3mm width or girth.

d ydM+h ds ^^LFkkfir** dk;Z dh njsa mu dfM+;ksa ij ykxw gksrh gS


tks xkMZj] fyVay nhokj IysV] /kju dkVdM+h o dVku dM+h dks
NksM+dj dSpha /kju oRrk /kkjd rFkk c<+bZ ds og dke tks
vkerkSj ij Nsnksa o pwyks] usl ;k pwy ;k diksr iqaNh tksM+ks ds
}kjk ugha curhaA bu njksa esa 'kkfey gSa p<oka tksM+] v/kZ tksM+]
pkch yxkuk] eYy cukuk] [kkaps cukuk] pkSap] dVkbZ djuk]
frjNs ;k i[knkj Nksj cukuk] dkoys vkfn ds fy;s Nsn djuk
o yxkuk o Nhtu rFkk mUgsa mBkdj LFkkiu esa yxkuk ,ao NksVs
eksVs Je dk;Z tSls frjNs] <yoka xksy o ukd tSlh 3 feeh
vuf/kd PkkSM+h ;k xksykbZ ds Nsn cukuk Hkh 'kkfey gSA

108

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7 ydM+h dk;Z c<+bZxhjh
TIMBER IN SCANTLINGSContd...
ydM+h dh dfM+;ka& tkjh
(b) The rates for timber fixed also apply to fencing or similar
posts and shall be deemed to include for transporting and
distributing the posts at required intervals and holding
the same in the position in post holes while ramming around
or concreting.
(c) The rates for timber framed and fixed apply to
scantlings framed together with mortice and tenon, tusk
and tenon or dovetailed joints, as in trimmer and trimming
joists, roof trusses, etc. The rates include for coating framed
joints with glue before being put together. The rate also
include for the labours mentioned in (a) and (b) above
describing timber fixed.
(d) King and queen posts of roof trusses or any timber member
which is diminished, shall be measured their full
dimensions, before diminishing.
(e) Timber, either fixed or framed and fixed, shall be
measured as wrought, if not less than two surfaces are
planed. If portions only are planed, payment shall be made
as clean sawn and planing measured extra under
workmanship. In no case, shall the rate of clean sawn
timber planed in parts exceed the rate for wrought timber.
(f) The extra for using old timber includes for carefully taking
out old nails, screws, etc. cutting out defective portions if
any, and returning same to store, and all other labours
incidental to fabrication of old timber.
(g) For timber in framing, etc. cut from the solid to a curve
with parallel sides, 100 per cent shall be added in the rates
of the table below, the net dimension being measured.

PER CUBIC METRE

Timber fixed

Clean sawn

M&L

lkexzh
o Je

Except M&L
timber lkexzh

ydM+h o Je
jfgr

?k Nr dSafp;ksa dh jktk&jkuh cfYYk;ka ;k dksbZ vU; gkloku


ydM+h dk vax] gkl gksus ls igys muds iwjs ifjeki esa ekis
tk;sx
a As
M+ ydM+h ds dk;Z pkgs ^^LFkkfir** gksa ;k ^^cus gq, ;k LFkkfir** ds
gks ;fn nks ls de ijr ds vk;ksftr ugha gSs rks cus gq;s ekis
tk;sx
a As ;fn dsoy Hkkx vk;ksftr gSa rks ^^lkQ dVk** ds leku
Hkqxrku gksxk rFkk vk;kstu ^^dkjhxjh** ds vUrxZr vfrfjDr
ekik tk;sxkA [kaM essa vk;ksftr lkQ dkV dh ydM+h dh njsa
fdlh Hkh n'kk esa cus gq;s ydM+h ds dk;Z ls vf/kd ugha gksaxhA
p iqjkuh ydM+h ds iz;ksx ij vfrfjDr esa iqjkuh dhysa isp vkfn
/;ku ls fudkyuk ;fn gks rks nks"kiw.kZ Hkkx dks dkV fudkyuk
rFkk mls Hk.Mkj esa okfil djuk rFkk iqjkuh ydM+h dh lajpuk
esa vkus okyk izklkafxd Je 'kkfey gSA
N Bksl ydM+h esa ls pkS[kV vkfn ds o ;k lekukUrj dk;Z ij
fuEu rkfydk dh njksa esa 100 izfr'kr tksM+k tk;sxk] ifjeki
fo'kq} ekik tk;sxkA
izfr ?ku ehVj

ydM+h xfBr o LFkkfir

Wrought

xfBr

x ^^xfBr o LFkkfir** ydM+h dh njsa mu dfM+;ksa ij ykxw gksrh gSa tks


Nsn o /kqjh] usl o pwyksa ;k diksr iqN
a h tksMk+ s ds lkFk cukbZ xbZ
gSa tSlh drjuh o dkV dM+h Nr dVh vkfn es]a njksa essa tksM+ yxkus
ls igys ljsl dh ijr p<+kuk Hkh 'kkfey gSA njksa es]a ij d
o [k esa of.kZr ^LFkkfir* esa vkus okys Je Hkh 'kkfey gSA

Timber framed and fixed

ydM+h LFkkfir
lkQ fpjh

[k ydM+h ds ^^LFkkfir** dk;Z dh njsa bu ij Hkh ykxw gksrh gS% ckM+


yxkus ;k leku dk;Z ds [kaHkksa dh <qykbZ djuk] visf{kr nwjh ij
j[kuk] xM~<ksa esa yxkuk] HkjkbZ djuk ;k pkjksa vksj dahV HkjukA

Clean sawn

lkQ fpjh

Except M&L
timber lkexzh

ydM+h o Je
jfgr

Wrought

xfBr

Except M&L
timber lkexzh

ydM+h o Je
jfgr

Except
timber

ydM+h
jfgr

07027Second
class
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
soft-wood
in
28292.50 1150.00 29435.10 2292.60 29466.80 2324.30 30549.70 3407.20
scantlings
07028Second
class
hard-wood in
41228.70 1748.70 42850.50 3370.50 42882.30 3402.30 44504.10 5024.10
scantlings

07027 nwljh Js.kh dh


uje ydM+ h
dfM+;ks esa
07028 nwljh Js.kh dh
dBks j ydM+ h
dfM+;ks esa

109

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7& ydM+h dk;Z c<+bZxhjh
TIMBER IN SCANTLINGSContd...
ydM+h dh dfM+;ka& tkjh
izfr ?ku ehVj

PER CUBIC METRE


Rs.
07029Add if in repairs, to replace old and
decayed timber (including piecing,
scarfing, etc., of old and new timbers
if required) and removing defective

portions to store
07030Add to except timber rates if old
timber supplied by MES is used

07029 tksM+sa ;fn ejEer dk dk;Z gSa tSls iqjkuh o {kh.k


ydM+h dks cnyuk iqjkuh o ubZ ydM+h esa ;fn
visf{kr gks rks Nsn dkVuk] iV~Vh vkfn yxkuk
lfgr rFkk nks"kiw.kZ Hkkxksa dks Hk.Mkj igqpkauk
07030 tksM+sa **ydM+h jfgr** dh njksa esa ;fn ,e bZ ,l
}kjk nh xbZ ydM+h iz;ksx dh xbZ gSaA

1359.30
607.30

FILLET WORK
xksV fQysV yxkus dk dk;Z
PER RUNNING
METRE

2nd class softwood

iz f r ehVj

2nd class hardwood

f}rh; Js.kh uje ydM+h

Sectional area
Not exc Exc 3 & Exc 6 & Exc 13
07031 Plain fillets. 3 sq.cm n. exc n exc 13 & n. exc
6 sq.cm sq.cm
25 sq.cm
square,
rectangular or vuf/kd vf/k 3 vf/k 6 o vf/k 13
13 olseh o 25
triangular in 3 o lseh o 6
ols
e
h
vuf/kd olseh
section, clean
vuf/kd
vuf/kd
sawn, se-cured
Rs.
Rs.
Rs.
Rs.
with nails or
brads.M&L
14.70 19.40 31.60
47.30
07032 Ditto, but bullnosed, splayed,
chamfered or
rounded on one
edge or face,

M&L
17.70 23.40 37.50
54.20
07033 Except battens.
any of the fore2.30
4.50
6.70
10.00

going
2nd class softwood

f}rh; Js.kh dBksj ydM+h


dkV {ks=
Not exc Exc 3 & Exc 6 & Exc13
3 sq.cm n. exc n exc 13 & n. exc
6 sq.cm sq.cm 25 sq.cm

3 olseh vf/k 3 vf/k 6 o vf/k 13


vuf/kd o 6
13 olseh o 25
olseh vuf/kd olseh
vuf/kd
vuf/kd
Rs.

Rs.

Rs.

Rs.

31.40

27.60

45.40

68.30

25.40

34.00

54.20

82.50

3.30

6.50

10.10

15.40

07031 lknh xksV dkV esa


oxkZdkj] vk;rkdkj]
;k f=Hkqth] lkQ f?kjh
gqbZ dks dhy ;k pkscksa
ls yxkbZ gqbZ lkexzh
o Je

07032 mi;qDZ r] fdUrq vUnj


ls xksykbZ esa frjNh]
i[knkj ;k ,d Nksj
;k ij ls xksy dh
gqb]Z lkexzh o Je

07033 +ij dh fdlh


tSlh fdUrq o+rk

jfgr

2nd class hardwood

f}rh; Js.kh uje ydM+h

f}rh; Js.kh dBksj ydM+h


dkV {ks=

Sectional area
n. exc 6 Exc 6 & n Exc 13 & N exc 6 sq. Exc 6 & n. Exc 13 & n.
sq. cm exc 13
n. exc 25 cm
exc 13 sq. exc 25 sq.
sq.cm
sq.cm
cm
cm
07034 Add to Items
631 to 633, if
fixed
with
screws
07035 Ditto.if
wrought
07036 Ditto, if in
repairs or if
refixed in old

position

vu 6 oxZ vf/k 6 o 13 vf/kd 13 vu 6 oxZ


lseh
oxZ lseh vu o 25 oxZ lseh
lseh vu
Rs.
2.80
2.90

Rs.
2.80
3.90

Rs.
3.30
4.90

Rs.
2.80
2.90

1.50

2.00

3.40

1.50

vf/k 6 o vf/kd 13
13 oxZ lseh o 25 oxZ lseh 07034 tksM+sa en 631 ls
vuf/kd
vuf/kd
633 esa ;fn ispksa
Rs.
Rs.
ls LFkkfir

2.80
3.30
07035 mi;q Z D r] ;fn
3.90
4.90
xfBr gks
07036 mi;q Z D r ;fn
ejEer esa ;k ;fn

2.00
3.40
iqjkus LFkkiu esa nksckjk
yxk;s x;s gksa

110

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7 ydM+h dk;Z c<+bZxhjh
BATTENS FOR TILES, ETC.
Vkby vkfn ds o+ks QV~Vh
(a) Measurements shall be taken overall including both battens
and spaces. Deductions shall be made only for openings
exceeding 0.4 sqm each.
(b) The rates include for all straight and/or raking cutting
and waste; also for a larger section batten at eaves, if
required.
(c) Battens of sizes other than those given in the table or fixed
at other spacings shall be paid for pro-rata.

PER SQUARE
METRE

d eki oks o vUrjky nksuksa dks feykdj iw.kZr% dh tk;sxhA dVkSrh


dsoy 0-4 o eh ls vf/kd dh izR;sd fooj dh gh gksxhA
[k bu njksa esa lHkh lh/kh ,oa@;k dVkbZ o Nhtu rFkk vkSyrh ij
;fn visf{kr gks vf/kd cM+h dkV ds Ok+ks Hkh 'kkfey gSaA
x rkfydk esa nh xbZ eki ls fHkUu uki ds oks o fHkUu vUrjky ij
yxkus dk Hkqxrku lekuqikfrd gksxkA

Material & Labour


Softwood 2nd class

Hardwood 2nd class

f}rh; Js.kh uje ydM+h f}rh; Js.kh dBksj ydM+h


Sectional area

dsoy fLFkj.k] dkV


{ks=

Sectional area

dkV {ks=

dkV {ks=

Exc 5 &
n.exc 15
sq.cm

Exc 15 &
n.exc 25
sq.cm

Exc 5 &
n.exc 15
sq.cm

Exc 15 &
n.exc 25
sq.cm

vf/k 5 o
15 olseh
07037 Clean sawn vu

vf/k 15 o
25 olseh
vu

vf/k 5 o
15 olseh
vu

vu 15 o
25 lseh vu

bat- tens at 15
Rs.
cm centres 186.80
07038 Ditto at 20cm
134.40
centres
07039 Ditto at 25cm

centres
107.40
07040 Ditto at 30cm

centres
81.10

Rs.
337.50

Rs.
281.70

Rs.
494.60

Rs.
13.20

Rs.
17.80

259.50

207.50

384.50

10.10

13.90

208.10

169.70

311.90

8.20

11.40

156.60

132.10

238.70

6.70

8.90

07041 Ditto at 35cm

centres

156.40

131.40

288.50

6.40

8.60

80.40

izfr oxZ ehVj

Fixing only, any


sectional area

lkexzh o Je

Soft
wood

Hard
wood

uje
ydM+h

dBksj
ydM+h
07037 lkQ fpjs gq;s ydM+h
ds o+ks 15 lseh ek/; ij

07038 mi;q Z D r] 20 ls e h

ek/;ij
07039 mi;q Z D r] 25 ls e h

ek/;ij
07040 mi;qZDr] 30 lseh ek/

;ij
07041 mi;q Z D r] 35 ls e h

ek/;ij

TRELLIS WORK (JAFRI)


tkyhnkj dk;Z tkQjh
The following items exclude any posts, rails, or other supports,
which shall be measured separately. Doors and windows formed
in trellis work shall also be measured and paid for under these
rates but extra timber in surrounds, rails, stiles, braces, etc. as
also builders hardware shall be measured separately.

uhps dh njsa fdlh Hkh izdkj ds LRkEHk] iVfj;ks]a ;k nwljs lgkjs NksMd
+ j
gSa tks izFkd ekis tk;saxsA tkyh dk;Z esa cuk;s x;s f[kM+dh njoktksa
dks Hkh bu njksa ds vUrxrZ ekik tk;sxk fdUrq iVfj;ka] lhf<+;ka]
ca/ku ifV~;ka vkfn pkjksa vksj dh vfrfjDr ydM+h rFkk fuekZ.k
miknku izFkd ekis tk;saxsA

111

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7& ydM+h dk;Z c<+bZxhjh
TRELLIS WORK (JAFRI)-Contd....
tkyhnkj dk;Z tkQjh tkjh
PER SQUARE METRE
07042 35mm x 10mm laths
(fixed straight or diagonally) in two way trellis
work with 50mm spaces
in the clear, including
75mm x 50 mm fillet
(notched to take ends of
laths) all round and

fixed complete
07043 As in item 645, but 40
mm x l2mm laths with
75mm spaces in the

clear, ditto
07044 Ditto but with 100mm
spaces in the clear,

ditto

izfr oxZ ehVj


lkexzh ,ao Je
07042 35 feeh 10 feeh dh
Softwood 2nd class
Hardwood 2nd class
QfV~V;ka lh/kh ;k fod.kZr
f}rh; Js.kh uje ydM+h
f}rh; Js.kh dBksj ydM+h
yxh gqbZ f}ekxhZ tkyh dk;Z
Clean sawn Wrought
Clean sawn Wrought
esa 50 feeh Li"V Qklys ij
lkQ fpjh gqbZ cuh gqbZ
lkQ fpjh gqbZ cuh gqbZ
75 50 feeh ds oks QfVV~;ksa
Rs.
Rs.
Rs.
Rs.
dks yxkus ds [kkaps cuk;s gq;s

pkjksa vksj yxkdj lai.w kZ


661.80
684.90
1017.40
1040.60
07043 en 645 tSlk fdUrq 40
12 feeh dh QfVV~;ksa ds
lkFk 75 feeh dh Li"V
712.50
735.70
1127.90
1151.10

nwjh mi;qZDr
Material & Labour

610.10

633.20

942.20

965.40

07044 mi;qZDr] fdUrq 100 feeh


dh LiV nwjh mi;qZDr

BOARDING IN ROOFS, CEILINGS, PARTITIONS, FASCIA, BARGE, SOFFIT, ETC. (EXCEPT FLOORING AND SKIRTING)
Nrksa] Hkhrjh Nrksa] foHkktuksa] eq[kvksyrh] ctjk] v/k%Lry vkfn
esa r[rkcanh Q'kZ o vapy fdukjh NksM+dj
(a) The rates include for all waste and straight or raking
cutting. Circular cutting shall be measured under items
07087 and 07088.
(b) All boarding shall be measured net when fixed, without
any allowance for laps.
(c) Boarding wrought on one or both sides shall be fixed with
bevelled heading joints, if so directed, without extra charge.
(d) The rates for fixing boarding to curved surfaces include
for shooting the joints to proper splay. Such boarding shall
not exceed 10cm in width.
(e) Where boards are fixed with open joints, the net area of
boards (excluding gaps) shall be measured.
(f) Edges of all boarding wrought on one or both sides shall be
planed square.
(g) If old boarding (any description) is supplied by M.E.S., an
addition of 20 per cent shall be made to the rates for fixing
only. This extra includes for taking out carefully old nails,
screws, etc. cutting out defective portions, if any, and
returning to Store and also for all other labours incidental
to fixing of old boarding.
(h) Boarding of thickness other than those shown below shall be
paid for pro-rata.

d bu njksa esa lHkh izdkj dh Nhtu rFkk lh/kh ;k frjNh dVkbZ


'kkfey gSA xksykdkj dVkbZ en 07087 o 07088 esa ekih tk;sxhA
[k iw.kZ r[rsacnh yx tkus ij] ySi ds fy;s vfrfjDr tksM+s fcuk
fo'kq) ekih tk;sxhA
x xfBr r[rkcanh dks ,d vksj ;k nksuksa vksj tSlk funsZf'kr gks]
i[knkj 'kh"kZ tksM+ ds lkFk fcuk vfrfjDr Hkqxrku ds LFkkfir
fd;k tk;sxkA
?k o lrg dh r[rscanh LFkkiu dh njksa esa] tksM+ksa dks i[kksa ls
Bhd ls feykuk 'kkfey gSA ,slh r[rscanh 10 lseh ls vf/kd
pkSMh+ ugha gksxhA
M tgka r[rs [kqys tksM+ksa ds gksa rks r[rs dks fjfDr;kaa NksM+dj
fo'kq) {ks= ekik tk;sxkA
p ,d vksj ;k nksuksa vksj dh r[rscanh dh cukoV ds fdukjksa ij
jUnk djds mUgsa le fd;k tk;sxkA
N ;fn iqjkuh r[rscanh fdlh Hkh izdkj dh ,e bZ ,l }kjk nh
tkrh gS rks **dsoy fLFkj.k** dh njsa 20 izfr'kr c<+ksrjh djds
nh tk;saxhA ;g vfrfjDr iqjkuh dhyksa o ispksa vkfn dks
/;kuiwod
Z fudkyus nks"kiw.kZ Hkkx ;fn dksbZ gks dks fudkydj o
Hk.Mkj esa okfil djus rFkk iqjkuh r[rscanh dks yxkus esa vk;s
LokHkkfod vfrfjDr Je ds fy;s gSaA
t uhps nh xbZ eksVkbZ ls vyx eksVkbZ dh r[rkcanh dk Hkqxrku
lekuqikfrd gksxkA

112

SECTION 7

SECTION 7WOODWORK (CARPENTERS WORK)


[k.M 7& ydM+h dk;Z c<+bZxhjh
BOARDING IN ROOFS, CEILINGS, PARTITIONS, FASCIA, BARGE, SOFFIT, ETC. (EXCEPT FLORRING AND SKIRTING) Contd...
Nrksa] Hkhrjh Nrksa] foHkktuksa] eq[kvksyrh] ctjk] v/k%Lry vkfn
esa r[rkcanh Q'kZ o vapy fdukjh NksM+dj& tkjh
PER SQUARE METRE

Softwood 2nd class

f}rh; Js.kh uje ydM+h


Boarding, supplied &
fixed with nails in any
situation (except flooring
and skirting)
07045 Clean sawn
with butt joints

07046 Planed one side


with butt joints

07047 Add to last if


planed both
sides
07048 Planed one side
and edges
tongued and
grooved or
rebated
07049 Add to last if
planed both

sides
07050 Fixing only
clean
sawn
boarding
07051 Fixing only
boarding
wrought on one
or both sides

izfr oxZ ehVj

Hardwood 2nd class

f}rh; Js.kh dBksj ydM+h

Thickness in mm

Thickness in mm

eksVkbZ feeh esa

eksVkbZ feeh esa

15

20

25

30

40

15

20

25

30

40

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

405

537

673

807

1076

615

814

1020

1221

1528

433

563

26.50 26.50

486

616

26.50 26.50

701

834

26.50 26.50

753

887

26.50 26.50

1102

26.50

1140

26.50

655

854

39.70 39.70

734

933

39.70 39.70

1058

1261

1567

39.70

39.70

39.70

1137

1339

1644

39.70

39.70

39.70

18.00 18.90

26.20 30.10

39.30

23.00 24.40

32.50

37.00

47.30

18.00 18.90

26.20 30.10

39.30

23.00 24.40

32.50

37.00

47.30

r[krscanh dh vkiwfk djuk


dhyksa ls fdlh Hkh voLFkk esa
yxkuk Q'kksaZ o vapy fdukjh
dks NksMd
+ j
07045 lkQ fpjs gq ; s
Vddj tksM+ lfgr

07046 ,d vksj jUns ls le


esa Vddj] tksM+

lfgr
07047 tksM]as+ fiNyh en es]a
;fn nksuksa vksj jUns

ls le fd;k gS
07048 ,d vksj lery
rFkk Nksjksa dks thHkh]
fNfnzr ;k f>jhnkj
fd;k x;k

07049 tksMs+a fiNyh en esa


;fn nksuksa vksj jUns
ls le fd;k gS

07050 lkQ fpjh gq b Z


r[rscanh dks dsoy

LFkkiu djuk
07051 ,d vksj ;k nksuksa
ls xfBr r[rsacnh
dk dsoy LFkkiu

113

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)


[k.M 7 & ydM+h dk;Z c<+bZxhjh
BOARDING IN ROOFS, CEILINGS, PARTITIONS, FASCIA, BARGE, SOFFIT, ETC.
(EXCEPT FLOORING AND SKIRTING) -Contd...
Nrksa] Hkhrjh Nkksa] foHkktuksa] eq[kvksyrh] ctjk] v/k%Lry vkfn
esa r[rkcanh Q'kZ o vapy fdukjh NksM+dj - tkjh
PER SQUARE METRE

Softwood 2nd class

izfr oxZ ehVj

Hardwood 2nd class

f}rh; Js.kh uje ydM+h

f}rh; Js.kh dBksj ydM+h

Thickness in mm

Thickness in mm

eksVkbZ feeh esa

eksVkbZ feeh esa

0 7 0 5 2 tksM+sa en 07046 esa ;fn


r[rscanh ,d vksj ls
[kkapsnkj i[knkj rFkk
Rs. Rs. Rs.
Rs.
Rs. Rs.
Rs.
Rs. Rs.
Rs.
r[rscanh lqesy dh
39.70 43.40 47.10 50.80 58.20 59.50 65.10 70.80 76.46 84.90
xbZ gS
07052A Ditto both sides and
0 7 0 5 2 , mi;qDZ r] nksuksa vksj rFkk

ditto
mi;qZDr
57.40 61.10 64.80 68.50 75.90 80.90 86.50 92.20 97.80 106.30
07052

Add to Item 07046 if


joints are chamfered
one side and the
boarding is matched

15

20

25

30

40

15

20

25

30

40

Extra over boarding if :

07053

Fixed with screws

07054

Fixed in ceilings

07055
07056
07057

07058

11.30 11.30 13.60 13.60 13.60 11.30 11.30 11.30

3.20 3.40 4.20


Framed or dovetailed 35.70 37.30 39.10
Fixed on curved sur5.30 7.10 7.90

face
Fixed in shelves; Partitions and shelves of
built-in cupboards,
almirahs, book cases,
toilet boxes, racks,
pelmets and similar
1.90 2.10 2.60
work
In repairs to replace
old and or decayed
boarding in patches
including cutting out
old, piecing, heading
joints, etc.
7.10 8.20 9.50

4.50

5.30 5.00

5.30 6.30

13.60 13.60
6.90 8.20

r[rs c a n h ij vfrfjDr ;fn%


0 7 0 5 3 ispksa ls LFkkfir

40.20 42.60 53.40 56.80 58.70

60.50 64.00

0 7 0 5 4 v/k% Nr esa LFkkfir


0 7 0 5 5 Qjesnkj ;k diksr iqPNh

8.70

13.20 15.90

0 7 0 5 6 o lrg ij LFkkfir

3.40

0 7 0 5 7 rkdks] foHkktuksa vYekfj;ksa


ds rkdks]a iqLrd etwa kkvks]a
iz l k/ku cDlk] jS d ks a ]
iSYesV rFkk leku dk;Z
esa LFkkfir

2.90

9.80

10.60 7.90

3.20 2.60

10.60 9.00

10.60 11.90

2.90 3.20

3.70

0 7 0 5 8 ejEer esa iqjkus ,oa ;k


{kh.k r[rscna h dks VqdM+ksa
esa isou cnyuk] iqjkus
dh dVkbZ] dkVdj iqjkus
10.60 14.30 16.10 16.70
VqdM+s +ij ds tksM+
vkfn fudkyus lfgr

WEATHER BOARDING
[kq y h r[rs c a n h
(a) Measurements shall be taken net as fixed, without any
allowance for laps.
(b) The rates include for all straight or raking cutting and
waste, any circular cutting shall be measured under items
07087 and 07088 as applicable.

d fcuk p<+koh cV~Vs ds LFkkiu fo'kq) ekik tk;sxkA


[k bu njksa esa lai.w kZ lh/kh ;k frjNh dVkbZ o Nhtu 'kkfey gS]a dksbZ
Hkh xksykdkj dVkbZ en 07087 o 07088 esas tSlh Hkh ykxw gks ekih
tk;sxa hA

114

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)


[k.M 7 & ydM+h dk;Z c<+bZxhjh
WEATHER BOARDING -Contd...
[kqyh r[rscanh -tkjh
PER SQUARE METRE

07059 Weather boarding,


clean sawn, plain,
20mm thick or feather
edged 15 mm to 20mm
thick and fixed with
30mm laps

Softwood 2nd class

Hardwood 2nd class

f}rh; Js.kh uje ydM+h

f}rh; Js.kh dBksj ydM+h

Material &
labour

Fixing
only

Material & Fixing


labour
only

lkexzh ,oa
Je

dsoy LFkkiu

lkexzh ,oa
Je

dsoy LFkkiu

Rs.

Rs.

Rs.

Rs.

672.50

30.90

1021.10

43.50

07060 Weather boarding, clean


sawn, thickness 20mm
to 25 mm and rebated
on thick edge to give
20mm laps and fixed

781.80

30.90

1187.50

43.50

07061 Add to last, if wrought


both sides and edges
shot and chamfered
(on exposed edges)

66.10

66.10

99.00

99.00

783.20

30.60

1211.90

43.10

07062 Weather boarding, 25


mm thick, wrought
both sides, V-jointed to
give 20mm laps and
fixed
07063 All as above but
rebated and hollow
jointed
07064 Add to the foregoing, if
in repairs to replace
old
or
decayed
boarding in patches,
including cutting out
old, piecing, heading
joints
etc.,
and
removing dismantled
boarding to store

824.40

30.60

1251.60

43.10

Rs.

26.50

izfr oxZ ehVj

07059 [kqyh r[rscna h lkQ fpjh gqbZ


ydM+h dh lknk 20 feeh eksVh
;k 15 feeh ls 20 feeh eksVs
ruqikar o 30 feeh p<+ko lfgr
LFkkfir
07060 [kqyh r[rscna h lkQ fpjh
ydM+h dh 20 feeh ls 25
feeh eksVh rFkk 20 feeh p<+ko
nsus ds fy;s LFkwy fdukjs
ij iSrkeh ,oa fLFkj.k
07061 vafre en esa tksM]as+ ;fn nksuksa
oxysa o fdukjksa dks cuk;k
rFkk i[knkj fd;k gS ckgjh
fdukjksa ij
07062 [kqyh r[rscna h 25 feeh eksVh
nksukas vksj xfBr 20 feeh
Pk<+ko nsus ds fy;s V
tqM+kbZ ,oa LFkkfir
07063 lc ij TkSlk fdUrq [kqyh
o [kks[kyh tqM+h gqbZ
07064 iwox
Z keh esa tksMas+ ;fn ejEer
esa iqjkuh ;k {kh.k r[rscUnh
dks cnyus ds fy;s iSpksa dks
dkV dj iqjkus VqdM+k]as ijh
tksMk+ as vkfn dks fudkyuk ,oa
m[kkM+h xbZ r[rscna h dks
Hk.Mkj esa igqWpkus lfgr
dk;Z gS

BOARDED FLOORS AND SKIRTINGS


r[rsnkj Q'kZ vkSj vapy fdukfj;ka
(a) The rates for flooring include for cramping or wedging up
(or laying folding), and also for punching nails or letting
in screw heads including stopping and cleaning off to a
smooth and even surface after floors are laid.

d Q'kZcUnh dh njksa esa f'kdats ;k Quuh yxkbZ ;k cfyr fcNkbZ


'kkfey gS] rFkk dhy ;k ispksa ds fljksa dks vUnj nckuk] Hkjr
o Q'kZ fcN tkus ds ckn lrg dh lQkbZ djrs gq;s le o
fpduk cukuk Hkh 'kkfey gSA

(b) The rates also include for all straight or raking cutting,
notching and waste; circular cutting shall be measured
under items 07087 and 07088.

[k njksa esa lc lh/kh ;k frjNh dVkbZ [kkapns kjh o Nhtu Hkh 'kkfey
gS( xksykdkj dVkbZ en 07087 o 07088 ds vUrxZr ekih tk;sxhA

115

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)


[k.M 7 & ydM+h dk;Z c<+bZxhjh
BOARDED FLOORS AND SKIRTINGS -Contd...
r[rsnkj Q'kZ vkSj vapy fdukfj;ka -tkjh
(c) If rebated and filleted floors with loose fillets are to be laid,
payment shall be made as for tongued and grooved flooring.

x ;fn irkeh ;k iV~Vhnkj] <hyh ifV~V;ksa ds lkFk Q'kZ Mkyus gSa


rks Hkqxrku thHkh o [kkapsnkj Q'kZ yxkbZ ds leku gksxkA

(d) The rates include for provision of heading joints.

?k bu njksa esa 'kh"kZd tksM+ksa dk izko/kku Hkh 'kkfey gSA


M 20%**dsoy fcNkbZ** dh njksa esa tksM+k tk;sxk ;fn iqjkuh
r[rscna h ,e bZ ,l }kjk nh tkrh gSA ;g vfrfjDr iqjkus dhy]
isp vkfn dks /;ku iwoZd fudkyuk] nks"kiw.kZ Hkkx] ;fn dksbZ gks]
mUgsa fudkyuk o mUgsa Hk.Mkj esa okfil djuk rFkk vU; iqjkuh
r[rscanh dks yxkus esa laHkkfor Je 'kkfey gSaA

(e) 20 per cent shall be added to the laying only rates if old
boarding is supplied by M.E.S. This extra includes for
carefully taking out old nails, screws, etc. cutting out
defective portion, if any, and returning same to store and
all other labour incidental to laying floor with old
boarding.
PER SQUARE METRE
Boarding in
Skirting

Softwood 2nd class

Hardwood 2nd class

f}rh; Js.kh uje ydM+h

f}rh; Js.kh dBksj ydM+h

Thickness in mm

Thickness in mm

eksVkbZ feeh esa

eksVkbZ feeh esa

Floors and

07065 Planed one side, with


butt joints and fixed
with nails supplied and

fixed

25

30

Rs.

Rs.

683

816.60

25

30

825.50 984.70

07068 All as in item 07067


but secret nailed

837.30 1003.20 1309.50 1272.10 1516

07069 Laying only, ditto

32.10

41.40

54.10

38.70

50.50

07070 Add to Items 07065


to 07067,
if
fixed

with screws

15.60

15.60

15.60

15.60

15.60

07071 Add to Items 07065 to


07069 for repairs to
existing floors in
patches, including
cutting out, piecing,
heading joints etc.

27.70

Q'kks Z a o va p y fdukfj;ks a es s a
r[rs c a n h

0 7 0 6 5 Vddj] tksM+ ds lkFk] ,d


vksj jans ls le o dhyksa ls
Rs.
Rs.
Rs.
Rs.
LFkkfir] vkiwfrZ ,oa LFkkfir
1079.10 1032.80 1235.20 1632.80

0 7 0 6 6 ,d vksj ls le rFkk fdukjs


ftHkh] o [kkapns kj ;k irkeh]
mi;qZDr
40

07066 Planed one side &


edges tongued and
grooved or rebated,

and ditto
07067 Laying only any of the

foregoing

20.10

izfr oxZ ehVj

40

1294.70 1250.70 1490.40 1960.80


36.00

Rs.

32.00

26.00

34.70

0 7 0 6 7 +ij ds fdlh esa dsoy


LFkkiu

0 7 0 6 8 lc en 07067 tSlk] fdUrq


1981.30
dhyksa dh xqIr tqM+kbZ
65.80 0 7 0 6 9 dsoy fcNkbZ] mi;qZDr
43.70

15.60

0 7 0 7 0 tksM+sa en 07065 ls 07067


esa ;fn ispksa ls LFkkfir

07071 tksMas+ en 07065 ls 07069


es]a dkV dj fudkyus] fLFkj
djus] tksM+ cukus lfgr
fo|eku Q'kksaZ dh VqdM+kas
es a ejEer ds fy;s

116

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)


[k.M 7 & ydM+h dk;Z c<+bZxhjh
PILING
ikby cukuk [kw a V s
(a) The contractor shall be paid for the lengths of piles ordered.
Cut-off portions shall be returned to Store.
(b) The rates for driving include either vertical or battered
work.
(c) The rates for piling are comprehensive rates; extra allowance as mentioned in 1.14.1 of Section 1 General Rules
shall not be allowed in addition.

d Bsdsnkj dks ikby dh vknsf'kr yEckbZ dk gh Hkqxrku gksxkA


[k xkM+us dh njksa esa ;k rks [kM+k <yoka dk;Z 'kkfey gSA
x ikby xkM+us dh njsa lekos'kh njsa gSaA [kaM 1 ds lkekU; fu;e
1-14-1 esa fufgr vfrfjDr blesa Lohd`r ugha gksxkA

[kw V s

PILES
PER RUNNING METRE
07072 Bally piles, hardwood, any class,
15cm mean dia, cut to lengths
required (n exc 9m) and planted
in position ready for driving

07073 Ditto but of 20cm mean dia

M&L

Except timber

lkexzh o Je

ydM+h jfgr

Rs.

Rs.

73.40
93.90

9.40
12.40

HEADING AND POINTING


PILES

iz f r ehVj
07072 cYyh ikby] visf{kr yEckbZ esa dVs] 9 eh
vuf/kd 15 lseh ek/; O;kl okys fdlh Hkh
Js.kh dh ydM+h ds LFkkiu esa pkyu dks izLrqr
07073 mi;qZDr] fdUrq ek/; O;kl 20 lseh

ikby ds khkZ cukuk o Vhi djuk

PER PILE

Other than in
tide work

07074 Heading and pointing Bally


piles 15cm mean dia, including
fixing only rings, providing
and fixing pile shoes, cutting
of heads after driving and
taking off rings, removing cut
off portions to Store
07075 Heading and pointing Bally
piles 20cm mean dia, including
fixing only rings, providing
and fixing pile shoes, cutting
of heads after driving and
taking off rings, removing cutoff

portions to Store
07076 Deduct from foregoing items if
pile shoes are not provided

Tokj ds vykok
dk;Z esa

In tide work

iz f r ikby

Tokj dk;Z esa

Rs.

Rs.

339.90

339.90

403.60

403.60

07074 15 lseh ek/; O;kl ds cYyh ikbyksa esa


NYys yxkuk uky dk izko?kku djuk o
yxkuk ikbyksa ds yxkus ds ckn 'kh"kZ dh
dVkbZ djuk] NYys fudkyuk o dVs Hkkxksa
dks Hk.Mkj igqapkuk 'kh"kZ cukuk o Vkafdr
djuk
07075 20 lseh ek/; O;kl ds cYyh ikbyksa esa
NYys yxkuk uky dk izko?kku djuk o
yxkuk] yxkus ds ckn 'kh"kZ dkVdj NYys
fudkyuk] dVs Hkkx dks HkaMkj igqapkuk o
'kh"kZ cukuk o Vkafdr djuk

73.40

07076 fiNyh enksa esa ls ?kVk;sa] ;fn ikby dh


ukyksa dh O;oLFkk ugha dh xbZ gS

73.40

117

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)


[k.M 7 & ydM+h dk;Z c<+bZxhjh
PILE DRIVING
ikby xkM+ u k
Other than in
tide work

PER RUNNING METRE

07077 Driving Bally piles 15cm


mean dia (portion in ground
only to be measured), n exc 6m

in depth
07078 Ditto. 20cm mean dia (ditto),

ditto
07079 Add to item 07077 for every additional one metre depth upto

a total depth of 8m
07080 Add to item 07078 ditto

In tide work

Tokj ds vykok
dk;Z esa

iz f r ehVj

Tokj dk;Z esa

Rs.

Rs.

29.80

29.80

40.40

40.40

22.60

22.60

33.20

33.20

07077 15 lseh ek/; O;kl ds dsoy tehu ds


vUnj ds Hkkx dks ekik tk;sxk cYyh ikbyksa
dk 6 eh vuf/kd xgjkbZ esa LFkkiu
07078 mi;qZDr] 20 lseh ek/; O;kl mi;qZDRk
mi;ZqDr
07079 tksM+as en 07077 esa izfr ehVj vfrfjDr xgjkbZ
ds fy;s] dqy xgjkbZ 8 ehVj rd
07080 tksM+sa en 07078 esa mi;qZDr

PLUGGING TO WALLS, ETC.


nhokjksa vkfn esa MkVsa yxkuk

d nhokjksa esa miLdjksa dh etcwrh] rFkk ifV~V;ksa dh vlEc) NksVh


yEckbZ;ksa dh etcwrh vkfn ds fy;s MkVksa dh 1 eh vuf/kd
fxurh dh tk;sxhA
(b) The rates in the table below shall apply only to cases, where [k uhps dh rkfydk dh njsa dsoy ,sls ekeyksa esa ykxw gksaxha tgka
fixing by means of plugs is not included in the rates for
MkVksa lfgr fLFkj djus ds dk;Z dks ydM+h dk;Z ds fLFkj djus
fixing woodwork
dh njksa esa 'kkfey ugh fd;k x;k gSA
(a) Plugs for securing fittings to walls, and for securing short
detached length of fillets etc. (n. exc 1 m long) shall be
enumerated.

PER RUNNING METRE


(EACH ROW)
07081 Plugging to walls complete,
for wood fillets, grounds,
moulding, boarding, etc.,
at distances n exc 1 m

Brick Cement concrete or Add if in


wall
stone walls
repairs

bZV
nhokj

lhesaV dahV ;k
iRFkj nhokj

Rs.

Rs.

19.90

23.80

tksM+sa ;fn
ejEer esa 07081 ydM+h dh ifV~V;ks]a /kjkryks]a lkapks]a r[rscna h
Rs.
vkfn ds fy, ,d ehVj vuf/kd ds
4.80
vUrjky esa nhokjksa esa lai.w kZ MkV yxkuk
iz R ;s d

EACH
07082 Ditto for fittings, etc., or in

detached work

izfr ehVj izR;sd iafDr

13.70

16.00

3.40

07082 mi;qDZ r] miLdjksa vkfn ds fy;s ;k vlEc+)


dk;Z esa

118

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)


[k.M 7 & ydM+h dk;Z c<+bZxhjh
REPAIR TO TIMBER ROOF TRUSSES ETC.
ydM++h dh Nr dSafp;ksa vkfn dh ejEer
EACH

Clear span

iz R ;s d

lkQ ikV
Upto 4 Above 4 metres Above 8 metres
metres & upto 8 metres & upto 12 metres
07083 Taking down roof
trusses, coupled rafters

or trussed beams
07084 Ditto but including taking
down trusses etc., for renewal of any defective
members (timber renewed
to be measured separately)
and reassembling
07085 Housing and fixing
trusses etc. after repairs
including tightening
up wedges, cotters bolts

etc.

4 eh
rd

4 ls vf/kd o 8
eh rd

8 ls vf/kd o 12
eh rd

Rs.
57.60

Rs.
89.30

Rs.
176.70

173.30

312.90

443.10

88.70

142.30

223.00

07083 Nr dh dSfa p;ksa nksgjh dfM;ksa dSp


a hnkj
/kjuksa dks mrkjuk
07084 mi;qDZ r] fdUrq dSfa p;ksa vkfn ds nks"kiw.kZ
vaxksa ds uohuhdj.k ds fy;s ys tkuk
uohuhdj.k dh ydM+h izFkd ekih tk;sxh
rFkk nksckjk tksMu
+ s ds dk;Z lfgr
07085 QfUu;ksa] iPpM+ksa] dkcyksa dks dlus
lfgr ejEer ds ckn dSfp;ksa vkfn
dks O;ofLFkr djuk o fLFkj
djuk

WORKMANSHIP LABOUR ONLY


dkjhxjh ds fy;s dsoy Je
(a) The rates include for all mitres and stops.
(b) The rates for planning include smoothening sawn timber
and sand papering, if required, and also include for taking
off small arrises n exc 3 mm wide.
(c) For labour on hardwood, the rates shall be increased by 50%.
(d) For work carried out across grain (except scribing, notching,
circular culling, splaying ends or corners or pointed ends),
the rates shall be increased by 50%.
(e) For circular work, the rates for straight work shall be
increased by 100%.
(f) The rates for workmanship apply to labours not included in
other items and pertain to work both on bench and in
position.

d bu njksa esa lHkh izdkj dh dksfu;ksa o MV~Vs 'kkfey gSaA


[k leryhdj.k dh njksa esa fpjh gqbZ ydM+h dks fpduk djuk
o ;fn vko';d gks jsxeky djuk 'kkfey gS rFkk 3 feeh
vuf/kd mHkkjksa dks nwj djuk Hkh 'kkfey gSA
x dBksj ydM+h ds Je ds fy, njksa esa 50 izfr'kr dh o`f) dh tk;sxhA
?k ldy rUrqjpuk dk;Z ds fy;s flok;] [kqjpus] [kkaps cukuk]
xksy dVkbZ] frjNs Nksj ;k fdukjs ;k Vkafdr Nksjksa ds njksa dks
50 izfr'kr c<+k;k tk;sxkA
M xksy dk;Z ds fy;s lh/ks dk;Z esa 100 izfr'kr dh o`f) dh
tk;sxhA
p dkjhxjh dh njsa mu Jfedksa ij ykxw gksaxh tks vU; enksa esa
'kkfey ugha gS rFkk dk;ZiVy o LFky ij dk;Z nksuksa ls
lacaf/kr gSaA

119

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)

[k.M 7 & ydM+h dk;Z c<+bZxhjh


WORKMANSHIP LABOUR ONLY Contd...
dkjhxjh ds fy;s dsoy Je tkjh
PLANNING SURFACES

lrgksa dk vk;kstu lery


izfr oxZ ehVj

PER SQUARE METRE


Rs.
07086 Planning surfaces of softwood

07086 uje ydM+h dh lrgksa dk leryhdj.k

26.50

[kqjpuk] [kkapsnkjh] xksy dVkbZ vkfn

Scribing, Notching, Circular Cutting, etc.


PER RUNNING METRE

07087Labour only on softwood n. exc

25mm thick
07088Ditto exc 25 mm but n. exc 50mm

thick

Scribing Notching etc Circular


15 cm girth cutting

[kqjpuk

15 lseh ?ksjs ls xksy dVkbZ


vf/kd dh
[kkapns kjh

Rs.
12.90

Rs.
17.40

Rs
21.70

19.60

30.40

34.90

iz f r ehVj

07087 dsoy Je 25 feeh vuf/kd eksVh uje


ydM+h ij

07088 mi;qZDr] 25 feeh ls vf/kd fdUrq 50


feeh vuf/kd eksVh

PER SQUARE METRE


07089Ditto, exc 50mm thick

izfr oxZ ehVj


317.50

341.30

568.40

07089 mi;qZDr] 50 feeh ls vf/kd eksVh

BEADS, GROOVES, CHAMFERS, MOULDINGS ETC.

fdukfj;ka xksV] [kkaps] frjNs fdukjs i[k [kakps vkfn cukuk


PER RUNNING METRE PER CM
WIDTH OR GIRTH
07090 Chamfers, splays, grooves, rebates,
rounded angles, rounded nosings,
tongued and grooved edges (each
tongue and each groove measured)
etc., exc 3mm but n. exc 75mm girth

on softwood
07091 Beads, staff beads, flutes, reeds, ditto

07092 Mouldings n. exc 75mm girth, ditto

izfr ehVj izfr ls-eh- pkSM+kbZ ;k


ifjf?k
Rs.

2.60
3.40
4.20

07090

frjNs] <yoka] [kkap]s iSrke] xksy fd;s


dks.k] xksy fd;s x;s ftgh o [kkapns kj
fdukjs izR;sd thHk o [kkapk eisxk
vkfn dks 3 feeh ls vf/kd o 75 feeh
ls vuf/kd ?ksjs dh uje ydM+h ij

07091 fdukfj;ka] xt fdukfj;ka xksy f>jh]

xksy ufy;ka vkfn] mi;ZqDr


07092 lkaps] xksykbZ esa 75 feeh vuf/kd]

mi;qZDr

120

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)

[k.M 7 & ydM+h dk;Z c<+bZxhjh


BEADS, GROOVES, CHAMFERS, MOULDINGS, ETC. Contd...
fdukfj;ka xksV] [kkaps] frjNs fdukjs i[k [kakps vkfn cukuk tkjh

Rs.

PER SQUARE METRE


07093 All as per Item 07090 but exc 75mm

width or girth
07094 All as per Item 07091 exc 75mm but

n. exc 200mm width or girth


07095 Mouldings exc 75mm but not exc

200mm girth on softwood

izfr oxZ ehVj


07093 lc en 07090 tSlk fdUrq pkSM+kbZ ;k xksykbZ esa
75 feeh ls vf/kd
07094 lc en 07091 tSlk fdUrq pkSM+kbZ ;k xksykbZ esa
75 ls vf/kd fdUrq 200 feeh ls vuf/kd
07095 lkaps vkfn 75 feeh ls vf/kd fdUrq xksykbZ esa
200 feeh ls vuf/kd ds uje ydM+h ij

35.40
43.10
55.00

izfr 100 u-

PER 100 NOS


07096 Headings, cut (pointed or rounded)
and wrought to pales or palisades
of fencing of softwood exc 25mm
07097 Ditto, to posts including mitred
intersections where necessary exc

25mm
07098 Notches n. exc 15cm girth (n exc

25mm thick), cut in softwood


07099 Notches not exc 15cm girth (exc
25mm and not exc 50 mm thick) cut
in softwood

07096 f'k[kj] 25 feeh ls vf/kd uje ydM+h ds lhekacna h


ds dVs gq;s uksdnkj ;k xksy fd;s gq;s rFkk ?ksjs
;k dV ?ksjnkj x<+s gq;s
07097 mi;qDZ r] 25 feeh ls vf/kd [kEHkksa ds] tgka t:jh
gks izfrNsnu dkV ds

594.80
1189.70

07098 [kkaps 15 lseh vuf/kd xksykbZ ds 25 feeh


vuf/kd eksVs uje ydM+h esa dVs gq;s
07099 [kkaps 15 lseh vuf/kd xksykbZ ds eksVkbZ 25 feeh
ls vf/kd fdUrq 50 feeh ls vuf/kd uje ydM+h
esa dVs gq;s

528.70

1057.50

DRILLING HOLES

ojesa ls Nsn djuk


Holes up to 2 cm deep to be
paid for as 2 cm deep

Diameter or side

PER 100 NOS. (PER CM


OF DEPTH)

N exc. Exc. 15 mm & Exc. 30 mm &


15 mm n. exc. 30 mm n. exc. 50 mm

07100 Holes round, drilled or cut

in soft wood
07101 Holes square or rectangular

drilled or cut in softwood

C;kl ;k Hkqtk
vuf/kd 15 feeh ls vf/kd 30 feeh ls vf/kd
15 feeh 30 feeh vuf/kd 50 feeh vuf/kd
Rs.
132.20

Rs.
264.40

Rs.
528.70

176.30

330.50

660.90

2 lseh rd ds Nsnksa dk Hkqxrku


2 lseh ln`'; gksxk
izfr 100 u- xgjkbZ dk
izfr ls-eh-
07100 uje ydM+ h es a ojes ls ;k dkVs
gq ; s xks y Ns n
07101 uje ydM+h esa ojes ls ;k dkVs gq;s
pkSdksj ;k vk;rkdkj Nsn

121

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)

[k.M 7 & ydM+h dk;Z c<+bZxhjh


BALLIES

cfYy;a k
(a) The term fixed shall have the same meaning as for
timber fixed.
(b) The mean diameter of a bally shall be taken as average of
the diameters at the two ends.
PER RUNNING
METRE

Type 3 Ballies

uewuk 3 cfYy;ak
S&F

07102 Ballies, softwood, any


class & fixed

07103 Ditto, hardwood any

class & fixed


07104 Add to Items 07102
and 07103, if in
repairs to replace old
and decayed ballies,
including piecing and
scarfing etc., old and
new
ballies
(if
required),
and
removing old ballies

to Store

vk
o
LFkkiuk

Except
ballies

d **LFkkiuk** 'kCn dk ogh vFkZ gksxk tks **ydM+h LFkkiuk** ds


fy;s gSA
[k cYyh dk Ekk/; O;kl cYyh ds nksuksa Nksjksa ds O;kl dk vkSlr
fy;k tk;sxkA

Type 2 Ballies

uewuk 2 cfYy;ak
S&F

Except
ballies

uewuk 1 cfYy;ak
S&F

Except

cYyh
jfgr

vk
o
LFkkiuk

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

45.20

4.10

66.40

12.30

85.30

24.20

65.30

6.60

84.90

20.30

117.70

35.50

5.30

2.60

7.90

5.50

17.20

10.80

cYyh
jfgr

izfr EkhVj

Type 1 Ballies

vk
ballies
o
cYyh
LFkkiuk jfgr

07102 fdlh Hkh Js.kh dh uje


ydM+h dh cfYy;ksa dh
vkiwfrZ o LFkkiu

07103 mi;qZDr] fdlh Js.kh dh

dBksj ydM+h rFkk LFkkiu


07104 tksMs+ en 07102 o 07103
esa] ;fn ejEer esa iqjkuh
o {kh.k cfYy;ksa dks cnyk
x;k gS] rFkk ubZ o iqjkuh
cfYy;ksa esa Nsn djuk o
tksMu+ k ;fn t:jh gks ,oa
iqjkuh cfYy;ksa dks Hk.Mkj

igqp
a kuk lfgr

MATERIALS (Supplied only)

lkexzh dsoy vkiwfrZ


izfr ?ku ehVj

PER CUBIC METRE


07105

Rs.

Timber, clean sawn in


scantlings, boardings, etc.,
suitable for strutting, shoring,
centering, formwork and for
other temporary purposes

07106 Timber in
scantlings

clean

sawn

07107 Timber in clean sawn battens

or fillets

07105

18800.00

Vsdcanh] rVcanh] <wYkkcanh] Qjekcanh


rFkk vU; vLFkkbZ ms'; ds fy;s
mi;qZDr] QfV~V;ks]a r[rksa esa fpjh
gqbZ lkQ ydM+h

2nd class softwood

2nd class hardwood

f}rh; Js.kh uje


ydM+hydM+h

f}rh; Js.kh dBksj

R.s.
25850.00

Rs.
37600.00

07106 lkQ fpjh gqbZ ydM+h dh dfM+;ka

24898.20

35275.90

07107 lkQ fpjh gqbZ ydM+h dh QfV~V;ksa


;k o+ks

122

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)

[k.M 7 & ydM+h dk;Z c<+bZxhjh


MATERIALS (Supplied only) Contd.

lkexzh dsoy vkiwfrZ & tkjh


BOARDS OR PLANKS

Qyd ;k r[rs
uhps nh xbZ eksVkbZ ls vf/kd eksVkbZ dh njsa lekuqikfrd fudkyh
tk;sxhA

Rate for thickness other than those shown below shall be


worked out pro-rata.
PER SQUARE METRE

izfr oxZ ehVj

Thickness of board in mm

Qyd dh eksVkbZ feeh eaas

07108 2nd class softwood clean


sawn boards or planks,

width n exc. 25 cm
07109 2nd class hardwood,
ditto, width n exc. 20cm

15

20

25

30

40

Rs.

Rs.

Rs.

Rs.

Rs.

370.10

493.50

564.00

752.00

0710
071088 f}rh; Js.kh ds fpjs gq;s lkQ uje
ydM+h ds 25 lseh vuf/kd fdlh
616.90 740.20 987.00
Hkh pkSMk+ bZ ds Qyd ;k r[rs
0710
071099 f}rh; Js.kh dBksj ydM+h ds] mi;qDZ r
940.00 1128.00 1504.00
20 lseh vuf/kd fdlh Hkh pkSMk+ bZ ds

NAILS, TACKS AND SCREWS

dhysa] esa[ksa o isp


Length

yEckbZ

PER KILOGRAM
07110

07111

07112

07113

07114

Plain head, lost head,


lath, mild steel wire nails,
bright finished

Panel pins n. exc 25mm


long, 1.00 mm to 1.60 mm
dia
Clout, slate or felt and
extra large felt nail, exc 25

mm in length
Cut-lath nails (cut-tacks),
15 mm to 25 mm long and
1.8 to 2.00 mm in dia
Ditto, but exc 25 mm & n.
exc 40 mm length and
2.00 to 2.40 mm in dia

Upto 50 mm

Exc 50 mm
but n. exc
80 mm

Exc 80 mm
but n. exc
150 mm

50 feeh rd

50 ls vf/kd
80 feeh
vuf/kd

80 ls vf/kd
150 feeh ls
vuf/kd

Rs.

Rs.

Rs.

56.40

52.90

52.90

Rs.
61.10

52.90

52.90

52.90

izfr fdyksxzke
07110 lkns flj] flj jfgr] /kkrq] uje
yksgs dh rkjh dhysa] pedhyh
jpuk okyh
07111 fnYys dhy] 25 feeh vuf/kd yEch
1-00 feeh ls 1-60 feeh O;kl dh
07112 crklk] LysV ;k xn~nh o cM+h
xnnhnkj dhys] 25 feeh ls
vf/kd yEch
07113 dkV /kkrq dhysa pknj&Vkadk 15
feeh ls 25 feeh yEch o 1-8 ls 2
feeh O;kl dh
07114 mi;qDZ r] fdUrq 25 feeh ls vf/kd
o 40 feeh vuf/kd yEch o 2-0 ls
2-40 feeh O;kl dh

123

SECTION 7

SECTION 7 WOODWORK (CARPENTERS WORK)

[k.M 7 & ydM+h dk;Z c<+bZxhjh


MATERIALS (Supplied only) Contd.

lkexzh dsoy vkiwfrZ & tkjh


WOOD SCREWS

ydM+h esa yxkus okys isp


PER 100 NOS.

izfr 100 u]

Rs.

07115 Mild steel wood screws, bright


finished, with slotted countersunk
head, designation 4 to 10 (2.74 to 4.88
mm nominal shank dia) n. exc 50 mm

long
07116 Ditto, designation 12 to 14 (5.59 to
6.30 mm, ditto), exc 50 mm but n. exc

100 mm long

58.70

0711
071155

uje yksgs ds dk"B isp] pedhyh


lrg] [kkafpr 'kad[q kkr 'kh"kZ] inuke 4
ls 10 2-74 ls 4-88 feeh ukHkh; ek/
; O;kl 50 feeh vuf/kd yEcs

0711
071166

mi;qDZ r] inuke 12 ls 14 5-59 ls 630 feeh] mi;ZDq r 50 feeh ls vf/kd


fdUrq 100 feeh ls vuf/kd yEcs

70.50

fofo/k oLrq,sa

MISCELLANEOUS
Rs.

PER KILOGRAM
07117 Glue

izfr fdyksxzke

94.00

07117 ljsl

15 to 25mm long, 30 to 50mm long,


1.60mm to 1.80mm 1.80mm to 2.50mm
in dia
in dia

PER KILOGRAM

07118 Staple
(Steel
pointed, bright

wire),

07119 Ditto, galvanised

15 ls 25 feeh yEcs
1-60 ls 1-80 feeh
O;kl O;kl

30 ls 50 feeh yEcs
1-80 ls 2-50 feeh

R.s.

Rs.

47.00

44.60

52.90

50.50

izfr fdyksxzke

07118 dqykck bLikr rkj uqdhyk]


pednkj
07119 mi;qZDr] tLre<+s

SPIKES
Rs.

dka V s
izfr fdyksxzke

47.00

071
20 uje yksgs ds dkaVs dVksjh flj ;k
07120
dqkk dkaVs 10 ls 20 lseh yEcs

PER KILOGRAM
07120 Mild steel spikes, rose
headed or dog spikes, 10 to

20 cm long

CkfYY;ka

BALLIES
PER RUNNING METER

iz f r ehVj
Softwood ballies

Hardwood ballies

cYyh uje ydM+h

cYyh dBksj ydM+h

Type 3 Type 2 Type 1 Type 3 Type 2 Type 1

uewuk 3 uewuk 2 uewuk 1 uewuk 3 uewuk 2 uewuk 1


Rs.
07121 Ballies in lengths from
3 to 9 m

Rs.

41.10 54.00

Rs.

Rs.

61.10

58.70

Rs.

Rs.

64.60 82.30

07121 3 ls 9 eh yEckbZ dh cfYy;ka

124

SECTION 8

SECTION 8JOINERY
[k.M 8 & c<+bZfxjh
SPECIAL CONDITIONS
foksk krsZ
8.1 Measurements

8-1 eki

The following method of measurement shall be


followed:

ekius dh fuEu fof/k viukbZ tk;sxh%&

1 yEckbZ;ka fudVre lsaVhehVj rd ekih tk;asxhA


(2) Width of surfaces formed by two or more boards shall 2 nks ;k nks ls vf/kd r[rksa ls cuh lrgksa dh pkSMk+ bZ dks fudVre
be measured to the nearest centimetre.
lsaVhehVj rd ekik tk;sxkA
(3) Width of single or detached boards and thickness of 3 ,dy ;k vlEc) r[rksa dh pkSM+kbZ ,oa leLr r[rscanh dh
all boarding shall be measured to nearest 2mm.
eksVkbZ] fudVre nks feeh rd ekih tk;sxhA
(4) Door and window frames and the like shall be 4 njokts o f[kM+fd;ksa ds se o leku dk;Z vuqizLFk dkV
measured to the nearest 2mm in cross sectional
vk;ru esa fudVre 2 feeh rd ekis tk;saxsA
(1) Lengths shall be measured to the nearest centimetre.

dimensions.
(5) Sections of members other than rectangular shall be
measured as the least rectangle or from which the
section can be obtained.
(6) In the case of member with a varying section, the
largest section shall be measured.

5 vk;r dks NksM+dj] vU; vaxksa ds [k.Mksa dh eki] U;wure


vk;rkdkj ;k ftlls og [k.M cuk;k tk ldrk gS] dh tk;sxhA

6 ifjorhZ vuqizLFk dkV ds ekeys esa lcls cM+s vuqizLFk dkV dks
ekik tk;sxkA
(7) Mitred pieces shall be measured along their longest length. 7 dyeh VqdM+s mudh lcls yEch yEckbZ ds lkFk ekis tk;saxsA
(8) In measuring framed timber, the length of tenons and 8 Qjesnkj ydM+h ekius esa /kqjh o [kkapksa dks Qjesnkj vax dh nkZ
scarfs shall be added to the sight length of the framed
yEckbZ esa tksM+k tk;sxkA
member.

8.2 Rates
(a) The rates for wooden joinery work shall include for
all surfaces to be wrought except the surfaces in
contact with the masonry, which may be left clean
sawn.
(b) Unless specifically mentioned to the contrary, the SSR
rates for joinery work (materials and labour or laying
or fixing only) include for nails, spikes, screws,
boring for and fixing of bolts etc. Bolts, nuts and
washers shall be paid for as Supplied only, without
any deduction for the value of nails displaced.
(c) The rates include taking off small arises n exc 3 mm
wide, when directed.
(d) The rates for fixing only include for the labour
required to fit and fix the prepared material in the
work and are exclusive of timber and fabrication but
include for jointing materials, such as nails, screws,
glue, pins, etc.
(e) The rates for except timber include in addition all
fabrication and preparation of the materials etc., except
the supply of clean sawn timber in required sections.
(f) Where no specific provision for extra payment for
curved or circular work in wooden joinery work is
made, the following rates shall be allowed :

8-2 njs a
d ydMh ds c<+bZ ds dke dh njksa esa] og lHkh lrgsa kkfey gSa
ftUgsa x<+k tkuk gS] flck; mu lrgksa ds tks fpukbZ ds lEidZ
esa gSa] ftUgsa fcuk x<+r ds NksM+k tk ldrk gSaA
[k tc rd fd foijhr u dgk x;k gks] ,l ,l vkj dh c<+bZ ds
dke dh njksa esa dsoy] Je] ;k fcNkuk ;k LFkkiu] dhys]a dkaV]s
isp] dkoys vkfn ds fy;s Nsn djuk o yxkuk vkfn kkfey
gSAa dkoys] f<ofj;ka] cklZy vkfn dk Hkqxrku] fudkyh xbZ dhyksa
dh ewY; dVkSrh ds fcuk **dsoy laifw k dh njksa esa fd;k tk;sxkA
x bu njksa esa] ;fn funsZk gks rks 3 feeh rd ds NksVs mHkkjksa dks
gVkuk Hkh kkfey gSA
?k **dsoy LFkkiu** dh njksa esas] cuh gqbZ lkexzh dks yxkus o fLFkj
djus ds fy;s visf{kr Je kkfey gS rFkk ydM+h o lajpuk dks
NksM+dj] tksM+us dh lkexzh tSls dhysa] isp] ljsl] es[ksa vkfn
kkfey gSaA
M **ydM+h jfgr** dh njksa esa lkexzh dh blds vfrfjDr la- jpuk]
o mie vkfn kkfey gSSa flok; visf{kr dkVksa dh fpjh gqbZ
ydM+h dh vkiwfrZ dsA
p tgka o ;k xksykdkj dk;kZs ds fy;s dksbZ foksk izko/kku ugha
fd;k x;k gS]a ogka fuEufyf[kr njksa dks Lohdkj fd;k tk;sxk%&

125

SECTION 8

SECTION 8JOINERY
[k.M 8 & c<+bZfxjh
SPECIAL CONDITIONS Contd...
foksk krsZ tkjh
In superficial work, circular on plan or elevation (e.g. in
shutters, partitions, framing, etc.) the circular portions
shall be measured square separately from the straight
portions and priced at twice the rates for straight work.

vuqfo{ksi ;k mn~fo{ksi ij lrgh dk;Z esa tSls dikVksa foHkktuksa]


Qjek canh vkfn esa xksykdkj dk;Z dks likV dk;Z ls vyx ekik
tk;sxk ,oa likV dk;Z dh njksa ls mldk ewY;kdau nqxquk gksxkA

8.3 Adjustment of Rates


8.3.1 Rates for wooden joinery work are given generally
for first class softwood and first class hardwood
unless otherwise indicated.

8-3 njksa dk lkeatLO;


8-3-1 ydMh ds c<+bZ ds dke dh njsa] tc rd fd vU;Fkk nfkZr
u gks] lkekU;r% izFke Js.kh uje o izFke Js.kh dBksj ydM+h
ds fy;s nh xbZ gSaA
8-3-2 tc dk;Z fHkUu Js.kh dh ydM+h ls fuLikfnr gksrk gS rks ,sls
dk;ksZ ds fy;s njsa fuEu rkfydk ds vuqlkj fu/kkZfjr dh
tk;sxhA fopkjk/khu dk;Z ds nj fu/kkZj.k esa ;g fof/k vU;
fof/k;ksa ij ojh;rk izkIr djsxhA

8.3.2 When work is executed in a different class of timber.


the rates for such timber shall be derived as shown
in the following table. This method shall take
precedence over any other method of deriving rates
for the work in question.
For work
in

var%dk;Z
gsrq

lk o J
vk o LFkk
njsa

ydM+h jfgr
;k dsoy LFkk
;k **dsoy
fcNkbZ**
njsa

lkexzh
**dsoy
vkaifw kZ**
njsa

Except timber
Deduct
or fixing only
55%
rates of 1st class from susoftwood shall
pplied
apply without only rates
any deduction.
of first
class softwood.

f}rh; Js.kh
uje ydM+h

izFke Js.kh
dh njksa eas ls
50 %?kVk;sa

fcuk dVkSrh
izFke Js.kh
dh njsa ykxw
gkax
s h

izFke Js.kh
dh njksa esa ls
55 %?kVk;sa

Except timber
or Fixing only
rates of 1st class
hardwood shall
apply without
any deduction

f}rh; Js.kh
dBksj ydM+h

izFke Js.kh
dh njksa esa ls
50 %?kVk;sa

fcuk dVkSrh
izFke Js.kh
dh njsa ykxw
gkax
s h

izFke Js.kh
dh njksa esa ls
55 %?kVk;sa

M&L (or S&F) Except timber Material


rates
or fixing
supplied
only rates or onlyrates
Laying only
rates

2nd class
softwood

Deduct 50%
from M&L or
S&F rates of
1st class
softwood

2nd class
hardwood

Deduct 50%
from M&L or
S&F rates of 1st
class hardwood.

Deduct
55% from
supplied
only rates
of 1st
class hard
wood.

SUB-SECTION A: WOODEN JOINERY


DOOR AND WINDOW CHOWKATS AND OTHER FRAMES
njokts] f[kM+fd;kas] dh pkS[kVsa o vU; <kaps
(a) The rates include for hardwood or bamboo pins and rebated
holes for hold fasts, bolts or screws including pelletting to
heads.
(b) Backs or portions of chowkats in contact with masonry etc.
may be left clean sawn.

d bu njksa esa] dBksj ;k ckal dh es[ksa o idM+ ifk;ksa-] dkoyksa ;k


ispksa ds fy;s irkeh Nsn] khkZ ij xV~Vd yxkuk kkfey gSA
[k bZaV dk;Z vkfn ds lEidZ ds pkS[kV ds fiNys Hkkxksa dks fcuk
x<+r ds NksM+k tk ldrk gSA

126

SECTION 8

SECTION 8JOINERY
[k.M 8 & c<+bZfxjh
SUB-SECTION A:WOODEN JOINERY
DOOR AND WINDOW CHOWKATS AND OTHER FRAMES Contd...
njokts] f[kM+fd;ksa] dh pkS[kVsa o vU; <kaps tkjh...
izfr ?ku ehVj
08001 lknk] Bksl] likV] x<h gqbZ pkS[kV o se]
izFke Js.kh uje izFke Js.kh dBksj
Bksl lrg ij xksykdkj ;k i[knkj irkes
ydM+h
ydM+h
okyh( tksMk+ as ij ljsl yxkdj] dhy Bksddj
Rs.
Rs.

tqM+h gqbZ( dh laiwfrZ o LFkkiuk


47066.10
77587.20
08002 mi;qZDr] fdUrq Bksl ydM+h ls cuh [kaMh;
08002 Ditto, but segmental, worked
67937.30
111888.80
PER CUBIC METRE

08001 Plain, solid, straight chowkats


and frames, wrought, framed rebated
on the solid, rounded or chamfered,
put together with glue pinned at

joints, supplied and fixed


from the solid

1st class softwood

1st class
hardwood

08003 Ditto, but semi-circular, worked


from the solid in two or more
sectors, dowelled and keyed with
double-headed hardwood keys
08004 Transomes or mullions, straight,
for solid frames of any description,
wrought, framed, double rebated
on the solid, rounded or chamfered
(including weathering to transome,
if required put together with glue,
pinned at joints), supplied and

fixed
08005 Extra over items 08001 to 08003 for
additional rebate for fixing second

shutter
08006 Extra over item 08004 for additional
rebate for fixing second shutter

90583.10

149185.00

08003 mi;qDZ r] fdUrq v/kZ xksykdkj] nks ;k vf/kd Hkkxksa


esa cuh dBksj ydM+h dh nksgjs fljksa dh pkfc;ka
yxkdj pkch;qDr rFkk xqTtk;qDr cukuk
08004 fdlh Hkh izdkj ds seksa ds fy;s] vkM+h]
frjNh ;k lh/kh cukoV] xksykdj ;k i[knkj
nksgjs irkes ;fn visf{kr gks rks vkM+h lrg
ij +_rq lg ( ljsl o dhy yxs tksM+
vkiwfrZ o LFkkiuk djuk

49516.00

80976.30

&

&

&

&

08005 vfrfjDr] en 08001 ls 08003 ij] nwljk


dikV yxkus ds fy;s vfrfjDr irke cukus
ds fy;s
08006 vfrfjDr] en 08004 ij] nwljk dikV yxkus
ds fy;s vfrfjDr irke cukus ds fy;s

SHUTTERS
dikV
(a) The term shutter covers all types of leaves and sashes in
woodwork whether fixed, hung or sliding, such as for doors,
windows, clerestorey windows, ventilators, fanlights,
skylights, lantern & northlights louvered or venetianed
shutters, cup-board fronts, framed and pannelled linings
or dados and similar work.
(b) The term glazed shutter means shutter or part of shutter
with panels divided into squares or rectangles with plain,
chamfered, rounded or moulded sash bars and glazed with
glass as indicated.
(c) Circular shutters shall be measured as square and
priced at twice the rate for straight work. Shutters
with semi-circular or segmental head shall be

d **dikV** kCn dh O;k[;k] lHkh izdkj ls ydM+h ds iYyksa o


pkS[kVksa pkgs og fLFkfjr gksa] yVdsa gksa] ljdoka gksa tSls fd
njoktks]a f[kM+fd;ks]a ijh f[kM+fd;ksa jkskunkuksa }kj eks[kks]a Nr
eks[kksa] yEcs nhokj eks[kksa] mkjh eks[kksa] f>yfeys vYekjh }kj
Qjesnkj] fnYysnkj fdukfj;ka ;k ifV~V;ka rFkk leku dk;kaZs dks
lekfgr djrh gSaA
[k **khksnkj dikV** dk vFkZ gS ,slk dikV ;k dikV dk Hkkx
ftlds iYys pkSdksj ;k vk;rkdkj :i esa foHkkftr gksa ftlesa]
likV] i[knkj] xksy ;k lacfa /kr la/kkj iV~Vh yxh gks o lkFk esa
fufnZVkuqlkj khks yxs gkssaA
x xksydkj dikV] oxZ tSls ekis tk;saxs ,oa budk ewY;kadu
lh/ks dk;Z dh njksa ls nqxquk gksxkA v/kZxksydkj ;k [kaM+h; khkZ
okys dikV nks Hkkxksa es ekis tk;saxs vk;rkdkj Hkkx rFkk ijh

127

SECTION 8

SECTION 8JOINERY
[k.M 8 & c<+bZfxjh
SHUTTERS Contd...
dikV tkjh...
oHkkx] ckn okyk Hkkx oxZ esa ekik tk;sxk iwjh pkSMk+ bZ xq.kk dsUnz
measured in two parts, the rectangular portion and
the upper curved portion, the latter being measured
ij WpkbZ rFkk ewY;kadu lh/ks dk;Z dh njksa dk nqxuq k gksxkA
as square (overall width by height at centre) and
priced at twice the rate for straight work.
(d) No extra width or labour shall be measured for rebated
and or splayed meeting stiles of door and window
shutters.
(e) Shutters with combination of two types (e.g. glazed
or venetianed upper portion and pannelled lower portion)
shall be measured in two portions. The dividing line for
measurements shall be the centre of the rail separating the
different portions.
(f) All shutters shall be framed except / ledged and battened
type and ledged, braced and battened type.
(g) Wood work in built-in wardrobes, cupboards etc. shall be
measured in detail under the appropriate items.
(h) The rates for shutters of doors and windows etc. are based
on the dimensions of various components or parts as
indicated in 8.24 of S.S.R. Part I. Any variation therefrom,
if ordered, shall be adjusted.
(j) The rates include for :
(1) Nails, screws, wedges and keys as required.
(2) Hardwood or bamboo pins to framed joints.
(3) Coating framed joints with glue before being put
together.
(4) Punching and clenching nails.
(5) Planing on all sides unless described as clean
sawn.
(6) Providing shutters in one leaf or more leaves, as
directed.
(7) All extra work due to diminished stiles, if directed.
(8) Sand papering to an even and smooth texture.
(9) Fitting of shutters to chowkats (and fixing in the case
of fixed shutters) and preparing for hanging, sliding,
etc. All builders hardware including hinges, pivots,
etc. shall be measured in addition, as supplied and
fixed.
(k) Shutters of thickness other than mentioned in the following
tables shall be paid for at prorata

?k njoktksa o f[kM+fd;ksa ds dikVksa esa irkes cukus vFkok ;k <yoak


[kM+h ifV~V;ka yxkus ds fy;s] pkSM+kbZ ;k Je esa dksbZ vfrfjDr
eki ugha gksxhA
M nks izdkj ds feys tqys dikVksa ;Fkk ijh Hkkx khksnkj ;k
vLrj.k rFkk uhps dk Hkkx fnYysnkj dks nks Hkkxksa esa ekik
tk;sxkA ekius ds fy;s] nksuksa Hkkxksa dks vyx djus okyh iVjh
ds dsUnz dks foHkktd js[kk ekuk tk;sxkA
p iqrokuh o ihnkj vkSj iqokuh] ca/kuh o ihnkj fdLe ds
dikVksa dks NksM+dj] lHkh dikV Qjesnkj gksaxsA
N fuekZ.k esa cus gq;s ckMZjkso] dioksMZ vkfn dsa ydM+h dk;Z dks
mi;qDr enksa ds vUrxZr foLrkj ls ekik tk;sxkA
t njoktksa f[kM+fd;ksa vkfn ds dikVksa dh njsa ,l ,l vkj Hkkx&1
mifof/k 8-24 ds fufnZVkuqlkj fofHkUu vaxksa ;k Hkkxksa ds ifjeki
ij vk/kkfjr gSAa fdlh Hkh vlaxfr dk ;fn vknsk gS rks mldk
lek;kstu fd;k tk;sxkA
> njksa esa fuEu kkfey gSa%&
1 visf{kr] dhysa] isp] iPpM+sa o pkfc;kaA
2 pkS[kVs ds tksM+ksa esa yxkus ds fy;s dBksj ydMha ;k ckal
dh kyk[kk;sAa
3 pkS[kVs ds tksMk+ as dks ,d lkFk yXkkus ls igys ljsl dh ijr
yxkukA
4 Nsn djuk o dhy yxkukA
5 tc rd lkQ fpjh gqbZ u dgk x;k gks ydM+h dks pkjksa vksj
ls jans ls lery djukA
6 funsZkkuqlkj dikVksa dh ,d iYys ;k nks iYyksa esa O;oLFkk
djukA
7 ?kVkoh ifV~V;ksa ds dkj.k] ;fn funsfZ kr gks]a rks lHkh vfrfjDr
dk;ZA
8 lrg dks le o likV cukus ds fy;s jsxeky ls f?klkbZ
djuk
9 dikVksa dks pkS[kVksa esa yxkuk tM+s gq;s dikVksa dks fLFkj
djuk rFkk yVdkus] ljdkus dh O;oLFkk djuk vkfnA
dCts] /kqfj;ka lfgr lHkh bekjrh miLdjksa dks blds vfrfjDr
*vkiwfrZ o LFkkfir* esa ekik tk;sxkA
= fuEu lkfj.kh esa nh xbZ fHkUu eksVkbZ ds dikVksa dk Hkqxrku
vkuqikfrd gksxkA

128

SECTION 8

SECTION 8JOINERY
[k.M 8 & c<+bZfxjh
SHUTTERS Contd...
dikV tkjh...
GLAZED AND SKELETON SHUTTERS

khksnkj rFkk <kapsnkj dikV


iYyksa la/kkj oxkZs ds khks ;k tkfy;ka izFkd ekih tk;sxhA

Glass or wire cloth, etc. in panels or sash squares shall be


measured separately.
PER SQUARE
METRE
08007 Glazed and skeleton
shutters,
open
rebated and prepared
to receive glass,
gauze, etc. (without
sash bars), edges of
framing
plain,
chamfered
or
rounded. fitted with
cut and mitred beads
for securing glass,
etc.; sizes of me-mbers
of
shutters
as
specified in SSR Part
I, Section 8, clause
8.24 (a); supplied and
fitted to chowkats

izfr oxZ ehVj

1st class softwood

1st class hard wood

izFke Js.kh uje ydM+h

izFke Js.kh dBksj ydM+h

Thickness of shutter in mm

Thickness of shutter in mm

dikV dh eksVkbZ feeh esa

dikV dh eksVkbZ feeh esa

25

30

35

Except 2 5
timber
any
thickness

30

35

fdlh Hkh
eksVkbZ dh
ydM+h
jfgr
Rs.

Except
timber
any
thickness

fdlh Hkh
eksVkbZ dh
ydM+h
jfgr

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

864.00

971.90

1086.10 281.30

1373.30 1550.90 1735.00 404.10

1019.10 1127.00 1228.00 354.80

1601.00 1778.70 1956.30 514.40

1042.60 1150.50 1252.00 378.30

1629.20 1806.90 1984.50 542.60

112.10

179.10

08008 Ditto, but divided into


squares, with plain,
chamfered or rounded, mitred and
rebated sash bars,

any numbers
08009 All as per item
08008 but with edges
of sash bars and
framing moulded
08010 Deduct from items
08007 to 08009 above
if
windows,
ventilators, etc. are
provided with stiles
and rails as specified
in SSR Part I, Section
8 clause 8.24(b)
08011 Add to items 08007
to 08009 if prepared
to slide horizontally
on beads including
supplying
and

fixing beads

132.10

150.90

14.60

14.60

212.00

244.90

18.10

08007 khksnkj o <kapns kj


dikV] tkyh vkfn
yxkus ds fy;s cuk;s
x;s [kqyh irkeh okys
dkafpr o <kafpr fcuk
la/kkj NM+ dikV(
fdukjs likV] i[knkj
;k xksykdkj] khks vkfn
dks idMus ds fy;s dVh
gqbZ dyeh xksVu( dikV
ds vaxksa dh eki ,l
,l vkj Hkkx&1 [kaM 8
ds mica/k 8-24 d ds
vuqlkj] vkiwfkZ rFkk mUgsa
pkS[kVksa esa cSBkuk
08008 mi;qDZ r] fdUrq oxksZ esa
foHkkftr] likV]
i[knkj ;k xks y ]
dyeh o irkeh fdlh
Hkh la [ ;k dh
la/kkj if;ka lfgr
08009 lc en 08008 tSlk
fdUrq x<s+ gq;s fdukjksa
okyh vk/kkj ifV~V;ksa
o pkS[kVs [kkapns kj
08010 ?kVk;sa en 08007 ls
08009 esa ls] ;fn
f[kM+fd;ksa jkskunkuksa
vkfn es]a ,l ,l vkj
Hkkx&1 [kaM mica/k 824[k ds vuqlkj [kM+h
ifV~V;ksa o iVfj;ksa dh
O;oLFkk dh xbZ gS
08011 tksM+as en 08007 ls
08009 esa ;fn xksVu
dh vkiwfkZ lfgr xksVu
ij lekukUrj <ky
cuk;k x;k gks

129

SECTION 8

SECTION 8JOINERY
[k.M 8 & c<+bZ fxjh
GLAZED AND SKELETON SHUTTERS Contd...
khksnkj rFkk <kpsnkj dikV tkjh...
PER SQUARE METRE

1st class hardwood

izFke Js.kh dBksj ydM+h

Supplied
and fixed

Supplied
and fixed

Rs.

Rs.

Rs.

92.10

31.90

134.70

52.40

144.60

87.40

213.40

131.10

2nd class softwood

2nd class hardwood

f}rh; Js.kh uje ydM+h

f}rh; Js.kh dBksj ydM+h

dikV dh eksVkbZ
feeh esa
Framed, ledged
braced
and
40
45
battened shutters,
Rs.
Rs.
supplied and
fitted to chowkats 1025.80 1124.10

Except
timber
any thickness

Thickness of
shutter in mm

dikV dh eksVkbZ
feeh esa

fdlh Hkh eksVkbZ


dh ydM+h jfgr
Rs.

40
Rs.

210.30

1911.80

izfr oxZ ehVj

Except
timber

Rs.

Thickness of
shutter in mm

08014

Except
timber

vkiwfrZ o ydM+h jfgr vkiwfrZ o ydM+h jfgr


LFkkiu
LFkkiu

08012 Deduct from item 08007 if


cut and mitred beads are
not supplied and fitted for

securing glass, etc.


08013 Deduct from items 08008

and 08009 ditto

PER SQUARE METRE

1st class softwood

izFke Js.kh uje ydM+h

08012 ?kVk;s]a en 08007 esa ls ;fn khks vkfn


dks Fkkeus ds fy;s dVh gqbZ dyeh xksVu
dh O;oLFkk o fLFkj.k ugha fd;k gS
08013
08013?kVk;sa] en 08008 o 08009 esas ls
mi;q Z D r
izfr oxZ ehVj

Except
timber
any thickness

fdlh Hkh eksVkbZ 08014 Qjesnkj] daxwjh] ca/kuh o


dh ydM+h jfgr
iV~Vhnkj dikVksa dh vkiwfk
45
djuk rFkk mUgsa pkS[kVksa esa
Rs.
Rs.
yxkuk
2150.30
308.30

PANELLED SHUTTERS
fnYys n kj dikV
1st class softwood
izFke Js.kh uje ydM+h

PER SQUARE METRE


08015 Plain, framed,
panelled shutters
(any number of
panels),
with
panels of timber
flat on both sides
(feather edged), or
of veneered particle
board medium
density, wood
particle board with
commercial face
veneers: supplied
and fitted to
chowkats
08016 Add to Item 08015
if framing is
moulded on solid
(for each side)

1st class hardwood


izFke Js.kh dBksj ydM+h

Thickness of shutter Except Thickness of shutter


in mm
timber
in mm
dikV dh eksVkbZ
any
dikV dh eksVkbZ
feeh esa
thickfeeh esa
ness

ydM+h
jfgr
25

30

40

Rs.

Rs.

Rs.

1085.20

49

1195 1414.80

49

49

Rs.

25

30

40

Rs.

Rs.

Rs.

241.40 1765.80 1946.80 2308.70

49

73.40

73.40

73.40

izfr oxZ ehVj

08015 l i k V ] Q j e s n k j ]
fnYysnkj dikV fdlh
la[;k esa fnYys ftlesa
ydMh+ ds nksuksa vksj
likV iq[kh fdukjs
ydM+h
fnYys ;k vLrj.k
jfgr
ikVhZ d y cks M Z ;k
vk;ksftr Qyd dgs
Rs.
vuqlkj nksuksa ijh
O;kolkf;d vLrj.k(
vkiwfkZ djuk o pkS[kVksa
es yxkuk
468.20
08016 tksM+as en 08015 esa ;fn
Qjesnkjh dks Bksl ij
lkafpr fd;k x;k gS
73.40
izR;sd vksj ds fy;s

Except
timber
any
thickness

130

SECTION 8

SECTION 8JOINERY
[k.M 8 & c<+bZ fxjh
PANELLED SHUTTERS Contd...
fnYysnkj dikV tkjh...
Rs.

PER SQUARE METRE

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

izfr oxZ ehVj

Rs.

08017 Ditto, if moulded


bead is provided
and planted round
the panels (for each

side)
08018 Ditto, if rebated
bolection moul
ded bead is pro
vided and planted
round the panels
(for each side)

169.10

169.10 169.10

46.80

246.20

246.20

246.20

70.10

218.60

218.60 218.60

96.30

322.00

322.00

322.00

145.80

08019 Ditto, if timber


panels are raised
and have bevelled
or
chamfered
margins (for each
side)

08017 mi;ZqDr] ;fn lkafpr


xksVu dh O;oLFkk dh gS
o mls iYys ds pkjksa
vksj yxk;k x;k gS
izR;sd vksj ds fy;s
08018 mi;qDZ r] ;fn irkeh mHkjh
lkafpr xksVu dh O;oLFkk
gS rFkk mls fnYys ds pkjksa
vksj yxk;k x;k gS izR;sd
vksj ds fy;s
08019 mi;qDZ r] ;fn ydM+h ds
fnYys mHkkjs gS rFkk
dVkoh o i[knkj Nksj
ifV~V;ka yxkbZ gSa

FACTORY MADE SHUTTERS


dkj[kkus ds cus dikV
PER SQUARE METRE

2nd class HW rail and style


f}rh; Js.kh dy iVjh o iV~Vh
Thickness of
Fixing only
shutters
any thickness
dikV dh eksVkbZ
dsoy LFkkiu fdlh
Hkh eksVkbZ ds
35mm
40mm
Rs.
Rs.
Rs.

08020 Plain framed, panelled


shutter (two panel) with
lock rail and panel of 9 mm
B.W.P. commercial ply or 12
mm veneered particle board
with commercial veneering
on both faces. The size of
rail and stile as per IS : 1003
(Part I), kiln seasoned and
chemically pressure treated 1583.00
08021 Ditto, without interlocking
rail and with one panel
1436.10
only ditto

1874.40

122.50

08020

08021
1728.70

122.50

izfr oxZ ehVj


likV Qjesnkj iYysnkj dikV
nks iYys ca/ku iVjh o iYys 9
feeh BWP O;kolkfgd IykbZ
;k 12 feeh ds nksuksa vksj ls
O;olkfgd vLrj.k ds vLrfjr
ikVhZdy cksMZ ls cus] iVjh o
ifV~V;ksa dk vkdkj IS &1003
Hkkx 1 ds vuqlkj] HkV~Vk idh
o jklk;fud nko mpkfjr
mi;qZDr] fcuk vrca/kZu iVjh o
dsoy ,d iYys okys] mi;qZDr

FLUSH SHUTTERS
likV
The rates for flush shutters include for the provision of suitable
blocks for taking mortice locks, latches, or other fittings.

likV dikVksa dh njksa esa] Hkhrjh rkys] vxZys ;k miLdj yxkus ds


fy;s mi;qZDr fi.Mksa dh O;oLFkk djuk] kkfey gSA

131

SECTION 8

SECTION 8JOINERY
[k.M 8 & c<+bZfxjh
FULSH SHUTTERSContd...
likV dikV tkjh...
S&F

Fixing only,

vk- o LFkkThickness in mm
eksVkbZ feeh esa
25
30
40

any thickness
dsoy LFkkiu]
fdlh Hkh eksVkbZ ds
ydM+h jfgr

PER SQUARE METRE

08022Flush shutters, solid core


construction, with block
board core and plywood
face panels, commercial

type on both sides


08023Ditto, but with particle

board core
08024 Add to items 08022 and 08023
if one face is covered with deco
rative face veneer with
lipping/frame to match
08025Ditto, if both faces, ditto

Rs.

Rs.

Rs.

Rs.

945.00 1027.20 1133.00

122.50

974.40 1056.60 1170.50

122.50

379.30

379.30

379.30

758.60

758.60

758.60

Rs.

EACH
08026Extra over flush shutters, any thickness,
for vision panels or peepholes, square
or rectangular including lipping
(supplying and fixing of glass measured

separately)

izfr oxZ ehVj


08022 likV dikV Bksl dksM cukoV
la;ksftr iVy dksM o nksuksa vksj
O;olkfgd fdLe dh ydM+h dh
ijr ds lkFk
08023 mi;qDZ r] fdUrq ikVhZdy cksMZ dksM
lfgr
08024 tksMa s + en 08022 o 08023 es]a ;fn ,d
vksj ltkoVh Qjes ls feyku dh fdukjh
lfgr vLrju ijr yxh gks
08025 mi;ZqDr] ;fn nksuksa vksj mi;qZDr

iz R ;s d
08026 vfrfjDr] fdlh Hkh eksVkbZ ds likV dikVksa ij]
oxkZdkj ;k vk;rkdkj ikjnkhZ ;k >kad fNnz fdukjh
lfgr khkksa dh vkiwfk o yxkbZ izFkd ekih tk;sxh
izfr oxZ ehVj

PER SQUARE METRE

08027 vfrfjDr likV dikVksa ij] ;fn oxkZdkj ;k vk;rkdkj


f>yfeys eks[kksa ds fy;s eks[kksa dk {ks=Qy ekik tk;sxk

08027Extra over flush shutters for venetion


openings, square or rectangular (Area

of opening measured)
08028Aluminium sheet, 0.5 mm thick, fixed

with aluminium alloy screws

08028 0-5 feeh eksVh vY;qfefu;e pknj vYeqfu;e


fefJr /kkrq ds cus ispksa ls LFkkfir

LOUVRED SHUTTERS
f>yfeyh dikV
PER SQUARE METRE
08029Framed louvred
shutters with stiles
and rails 100 to 120
mm wide and
panels filled with
fixed louvres from
10 to 15 mm thick,
supplied and fitted
to frames

1st class softwood

1st class hardwood

izFke Js.kh uje ydM+h

izFke Js.kh dBksj ydM+h

izfr oxZ ehVj

08029 Qjes n kj f>yfeyh


dikV] 100 ls 120 feeh
eksVkbZ
eksVkbZ
pkSM+h iVjh ;k iV~Vh
feeh esa
feeh esa
ds lkFk o iYys 10 ls
ydM+h jfgr
ydM+h jfgr
15 feeh eksVh LFkkfir
30
40
30
40
f>yfeyksa ls Hkjs( vkiwfkZ
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
djuk o pkS [ kVks a es a
yxkuk
1420.60 1680.40 325.50 2330.20 2771.10
490.80
Thickness
in mm

Fixing
only
any
thickness

Thickness
in mm

Fixing
only
any
thickness

132

SECTION 8

SECTION 8JOINERY
[k.M 8 & c<+bZfxjh
LOUVRED FRAMES
f>yfeys pkS [ kVs a

f>efeyh Qydksa ds vax o <ky funsZ kkuqlkj gksxkA Qykdksa ds ckgjh


fdukjs] pkS[kVs ds eksgjs ds lkFk likV gksaxsA

The number and slope of louvred blades shall be as directed.


The outer edges of blades shall he flush with the face of the
frame.
1st class softwood
izFke Js.kh uje ydM+h

1st class hardwood


izFke Js.kh dBksj ydM+h

izfr oxZ ehVj

Thickness of frames in mm

Thickness of frames in mm

pkS[kVs dh eksVkbZ feeh esa

pkS[kVs dh eksVkbZ feeh esa

0 8 0 3 0 f>yfey pkS[kVs 80 ls
100 feeh pkSM+s ftuesa
15 ls 20 feeh yxs gksa(
tksMksa ij ljsl dhysa
yxh( vkiwfkZ o LFkkfir

PER SQUARE
METRE
08030 Louvred frames 80
to 100 mm wide
with fixed louvres
of 15 mm to 20 mm
thick, frame put
together with glue,
pinned at joints,
supplied and fixed

50

75

100

50

75

100

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

2318.10

3028.00

3737.80

3858.70

5056.60

6254.40

MOULDING
la p du <ky

bu njksa esa dhyksa dk yxkuk mlds flj eksMUkk] nhokjksa esa fxV~Vd yxkuk]
likV djuk] fuosk djuk] fcBkuk o muesa ljsl yxkuk kkfey gSA

The rates include for planting and clenching heads of nails, plugging
to walls, tonguing, housing, bedding and gluing in.
PER RUNNING
METRE

iz f r ehVj

1st class softwood


izFke Js.kh uje ydM+h

1st class hardwood


izFke Js.kh dBksj ydM+h

Sectional area in sq. cm

Sectional area in sq. cm

dkV {ks= lseh esa


N exc.
6

Exc. 6 & Exc. 13 &


n exc. 13 n exc. 25

dkV {ks= lseh esa


N exc.
6

Exc. 6 Exc. 13&


&n
n ex.25
exc. 13

Exc 25&
N exc.
50

6 ls
6 ls
13 ls
6 ls 6 ls
13 ls
25 ls
vuf/kd vf/kd 13 vf/kd o vuf/kd vf/kd vf/kd o 25 vf/kd o
ls
25 ls
o 13 ls ls vuf/kd 50 ls
vuf/kd vuf/kd
vuf/kd
vuf/kd
08031 Moulding as in
cornices, picture
rails and the like
08032 Add to last if fixed
with screws

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

108.30

150.20

237.90

174.10

245.70

392.80

562.70

6.50

8.40

14.90

6.50

8.40

14.90

21.30

08031 lapdu tSlh dkjful]


fpf=r iVjh o leku
08032 vafre en esa tksaMsa+ ;fn
ispksa ls LFkkfir

TURNERS WORK
[kjknh dk dk;Z
(In bars for plate racks, poles for curtains, balustrade etc.)
(a) Square fillets or Scantlings of minimum cross section out
of which turned work can be produced shall be measured
as timber clean sawn and fixed or framed and fixed
according to the type of work.
(b) In work turned to varying diameters, the greatest diameter
shall be taken as the basic for measurements.

jSd IySV dh NM+ksa] ijnksa ds iksys MaMksa taxyksa vkfn esa


d pkSdksj iVjh ;k QfV~V;ksa fuEure vkM+h dkV] ftlesa ls [kjknh dke
dk mRiknu fd;k tk ldrk gS] dks *lkQ fpjh ydM+h o LFkkfir*
;k lkafpr o LFkkfir* esa dk;Z dh fdLe ds vuqlkj ekik tk;sxkA
[k fofHkUu vk;ruksa ds dk;Z dh eki esa lcls cM+s vk;ru dks
ewyvk/kkj fy;k tk;sxkA

[{
133

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
TURNERS WORKContd...
[kjknh dk dk;Z tkjh...
PER RUNNING METRE
Extra over timber supplied and
fixed, for turners work)

Hard wood

uje ydM+h

dBksj ydM+h

Rs.

Rs.

[kjknh ds dk;Z ds fy;s ydM+h dh vkiwfrZ


o LFkkiu ds fy;s vfrfjDr
08033 15 feeh O;kl ls vuf/kd
08034 15 feeh ls vf/kd o 25 feeh ls vuf/kd O;kl
08035 25 feeh ls vf/kd o 50 feeh O;kl ls vuf/kd

08033 N. exc 15 mm dia


08034 Exc 15 mm and n exc 25 mm dia

5.50

8.30

11.90

17.50

08035 Exc 25mm and n exc 50 mm dia

51.30

78.70

izfr oxZ ehVj


?ksjs ;k [kjknh dk;Z dh lrg dk

PER SQUARE METRE


(Extra over timber S&F for turners
work of girth or surface of turned work)

08036 Exc. 50 mm dia

iz f r ehVj

Soft wood

186.50

291.40

08036 50 feeh O;kl ls vf/kd

STAIR CASES

lks i ku lhf<+ ; ka

(a) The rates include for ploughing and cross tonguing, for
cross grooving and tonguing or rebating cross grain to
angle joints of strings; and for tenoning of strings into
newels and to trimmers of landings; and for housing floors
to receive tenons on feet of strings.
(b) The rates for bullnosed or semicircular ends to bottom
step include for building up the curved portion or riser
from solid blocks, dowelling, cross tonguing, etc. complete.
(c) In measuring the superficial area of treads and risers, the
actual length of tread shall be multiplied by the exposed
width of tread plus the rise from step to step.

d bu njksa esa vkMsa [kkaps cukus ds fy;s fuosk o vkM+sa c<kos cukus] lh<h
ds dks.kh; tksM+kas ds ?kVrs ;k c<+rs vkjikj Nsn djus] vk/kkj dh
dkaVNkaV rFkk lh<+h dks vk/kkj LrEHkksa ls tksM+uk rFkk uhps ds
vk/kkj dks QkZ esa yxkus ds fy;s LFkku cukuk kkfey gSsaA
[k ikoZ xksfyr ;k v/kZ xksykdkj /kjkry fdukjksa dh njksa es]a Bksl
Oykd essa ls o Hkkx ;k mHkkj cukus] fxV~Vd yxkus] vkM+h
dVkbZ vkfn ls iw.kZ kkfey gSaA

(d) The following shall be measured under Section


7 Woodwork (Carpenters work) :
(1) Open stairways (without risers) consisting of strings
and treads (housed into strings) shall be measured as
timber S&F or fixed only.
(2) Landings and bearers (half and quarter space) shall be
measured as flooring and scantlings
framed and fixed respectively.
(3) Carriages shall be measured as timber in scantling.

x iknksa o c<+koksa dh eki ds fy;s iknksa dh okLrfod yEckbZ dks


iknksa dh ckgjh pkSM+kbZ ls xq.kk djds mlesa in ls nwljs in ds
c<k+os dks tek dj nsaxsA
?k fuEufyf[kr [kaM 7& ydM+h dk;Z c<+bZ dk dke ds vUrxZr
ekik tk;sxh%&
1 [kqys lh<+h iFk mBkos jfgr izca/ku o ikn lfgr izoa/ku
esa yxs *vkiwfkZ o LFkkfir* ;k *dsoy LFkkfir* ds vUrxZr
ekis tk;sxsA
2 /kkj.kksa o /kkjdksa vk/kk o pkSFkkbZ vUrjky dks ^QkZ cukuk*
rFkk *Qf;ka yxh o LFkkfir* ekuqlkj ekik tk;sxkA
3 <kapksa dks *QfV~V;ksa esa ydM+h* ds leku ekik tk;sxkA

134

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
TREADS AND RISERS
lh<+h ds ik;nku o mBkos
PER SQUARE METRE

1st class
softwood

izFke Js.kh dh
08037 35 mm wrought treads with uje ydM+h
rounded
nosings, with 20 mm
wrought risers on tongued both
edges, glued, wedged and blocked

complete
08038 40 mm, ditto, with 25 mm wrought
risers, ditto

08039 Add to either of the foregoing, if in


winders (measured net but both

treads and risers included)

PER RUNNING METRE

Rs.

1746.30

1st class
hardwood

izFke Js.kh dh
dBksj ydM+h 08037 35 feeh ds xksy fdukjs okys x<+s gq;s ik;nku]
Rs.

2885.70

2148.00

3528.30

420.30

696.90

1st class
softwood

1st class
hardwood

08040 Nosings (rounded) 75 mm wide izFke Js.kh


and 35 or 40 mm thick, fixed to uje ydM+h
edges of landings to match stair
Rs.
treads, rebated to suit thickness of
flooring or as required, tongued and
grooved to same, including returned

ends
179.30

08042 Projecting semicircular end (ditto)

nksauksa fljkas ij likV 20 feeh x<+s gq;s mBkoksa


ds lkFk ljsl o es[ksa yxkdj cUn djds
laifw r
08038 40 feeh] mi;ZqDr] 25 feeh x<sa+ gq;s mBkos]
lfgr mi;qZDr
08039 ij dh fdlh en esa tksMsa+ ;fn p lh<+h esa
fokq): fdUrq ik;nkuksa o mBkoksa nksuksa lfgr
eisaxs

iz f r ehVj

izFke Js.kh 08040 lksikukxz xksykdkj 75 feeh pkSM+s o 35 ;k


dBksj ydM+h
40feeh eksVs lh<+h ds inksa ls feyku djds pkSdh
Rs.

ds fdukjksa es(a QkZ dh eksVkbZ ds vuqlkj ;k tSlk


pkfg;s irkeh] thHkh o [kkapns kj izR;kxkeh fdukjksa
lfgr] LFkkfir

290.40

iz R ;s d

EACH
08041 Bullnosed or quadrant end to
bottom step. (The tread and riser to
be measured net without the
bullnosed or quadrant end)

izfr oxZ ehVj

08041 ryikn ij CkSy ukldh; ;k prqFkkZak Nksj


ik;nkuksa o mBkoksa dks fcuk xksfyr ;k prqFkZka k
o Nksj dks fokq) ekik tk;sxk
164.90

222.70

227.30

363.50

08042 iz{ksih v/kZxksydkj Nksj mi;ZqDr

135

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
HOUSED STRINGS
fuos kh vkoa / kd
Ramped or circular portions shall be paid for at twice the
rates in this table and wreathed portions at three times the
rates.
PER RUNNING METRE

1st class softwood


izFke Js.kh uje ydM+h

<kyw ;k xksykdkj Hkkxksa dk bl rkfydk dh njksa ls nqxuk o yM+hnkj


Hkkxkssa dk frxquk Hkqxrku gksxkA
1st class hardwood
izFke Js.kh dBksj ydM+h

08043 Wall strings 20 cm wide


in straight lengths.
Thickness in mm
Thickness in mm
wrought one side, edges
eksVkbZ feeh esa
eksVkbZZ feeh esa
shot, housed for treads
40
50
60
40
50
60
and risers, and fixed
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
complete, including
401.30 498.40 597.60 660.90 810.00 982.00
plugging to walls
08044 Outer strings 20 cm
wide in straight lengths,
wrought both sides,
edges shot, housed for
treads and risers,
tenoned at ends to fit
newel posts or notched
to landings, etc., and
380.90
fixed complete
08045 Add to items 08043 and
08044 for additional
42.00
25mm in width

iz f r ehVj
08043 nhokj vkoa/kd] lh/kh yEckbZ esa
20 lseh pkSM]+s ,d vksj ls x<+s
gq;s feys fdukjs o ik;nkuksa o
mBkoksa dh fuosk O;oLFkk o
nhokj esa xV~Vs lfgr lai.w kZ
LFkkiu
08044 ckgjh vko/ku( lh/kh yEckbZ esa
20 lseh pkSMs+ okys nksuksa vksj ls
x<s+ gq;s fdukjksa ls feys gq;]s
ik;nkuksa o mBkoksa ds fy;s fuoskh
lksiku LrEHkksa esa fLFkj djus ds
fy;s pwynkj fdukjs ds lkFk
lai.w kZ LFkkiuk

481.00 578.10 640.60 803.60 967.50

52.20

59.60

65.20

82.40

98.20

08045 tksM]as+ en 08043 o 08044 es]a


vfrfjDr 25 feeh pkSMk+ bZ ds
fy;s

gFk iVfj;k
HANDRAILS
(a) Handrails shall be framed level or raking as required and
their length measured along top centre line.
(b) The rates include for cutting straight (or splay) tenons
on handrails, fixing to newel and for joining
continuous handrails with one double nut handrail
screw and two dowels to each joint.
(c) Handrails of sections other than those mentioned shall
be paid for pro-rata.
(d) Ramped or circular portion of handrails shall be paid
for at twice the rates for straight, and wreathed portion
of handrails shall be paid for at three times the rates
for straight lengths.

d gFkiVfj;ka vis{kkuqlkj lery ;k >qdkoh <kyh tk;sxh rFkk


mudh yEckbZ khkZ dsUnz js[kk ds lekukUrj ekih tk;sxhA
[k bu njksa esa gFkiVjh ij lh/ks <yoka tksMk+ as dh dVkbZ] lksikuksa LrEHkksa
esa yxkuk] rFkk vuojr gFkiVfj;ksa dks ,d nksgjs dkoys nqega s isp
ls tksMu+ k rFkk iR;sd tksM+ ij nks Mksoy
s xqt
a h kkfey gSAa
x ;gka nh xbZ ls fHkUu dkVksa dh gFkiVfj;ksa dk Hkqxrku vkuqikfrd
gksxkA
?k <kyw ;k xksykdkj gFkiVjh Hkkxksa dk nqxquk rFkk yM+hnkj Hkkxksa
dk lh/ks dk;Z ls frxquk Hkqxrku gksxkA

136

SECTION 8

SECTION 8 JOINERY
[k.M 8& c<+bZfxjh
HANDRAILSContd....
gFkiVfj;k& tkjh....
PER RUNNING METRE

1st class softwood

1st class hardwood

izFke Js.kh uje ydM+h

izFke Js.kh dBksj ydM+h

08046 Handrails rounded or


shaped with splayed
faces in straight
lengths and fixed

7560 mm

10075mm

Rs.

Rs.

Rs.

Rs.

232.00

373.00

381.30

613.70

08047 Ditto, but moulded

301.20

468.00

527.70

744.40

23.30

23.30

35.00

35.00

08048 Add to foregoing


items if sunk to receive
iron core

7560mm 10075mm

iz f r ehVj
08046 gFkiVfj;ka] lh/kh yEckbZ esa
eksgjs ij xksykdkj ;k
<yoka LFkkfir
08047 mi;qZDr] fdUrq lkafpr
08048 ij dh enksa esa tksM]as+ ;fn
ykSg dksj yxkus ds fy;s
f<yoka d;k gS

Handrail Caps and Scrolls

gFkiVjh Vksfi;ka rFkk


dq a M fy;ka

EACH

iz R ;s d

08049 Caps (turned to match


section of handrail
and mitred in)
including handrail
screws and dowels
(dia of cap twice the
width of handrail)
08050 Scrolls to suit handrail
rounded or shaped
with splayed faces
and fixed (dia of scroll
three times width of

handrail)
08051 Ditto, to suit moulded
handrail and fixed

(ditto)

08049 Vksfi;ka gFkiVjh o mlesa ds


fdjhVksa ds feyku ds fy;s
[kjknh gqbZ rFkk nks eqga s isp
o Mkosy( Vksih dk O;kl gFk
iVjh dh pkSMk+ bZ ls nqxu
q k
08050 dqMa fy;ka Vksih ds feyku dh
xksydkj ;k <yoka vkdkj dh
cuh rFkk LFkkfir dqMa yh dk
O;kl gFkiVjh dh pkSMk+ bZ ls
frxquk
08051 mi;qZDr] lkafpr gFkiVjh
ds feyku dh rFkk LFkkfir
djuk

146.20

252.20

226.00

398.20

292.40

504.30

452.00

796.50

324.20

612.70

533.60

967.10

NEWEL POSTS, BALUSTERS, ETC.


lksiku LrEHk pkSdh rFkk vkyacu vkfn
(a) Joints between newels and strings shall be double pinned
and between newels and handrails single pinned, with
hardwood pins (glued).
(b) If turned caps with dowelled joints are fixed to newels,
the length of newel is to be measured exclusive of the
caps.

d LrEHkksa o vkoa/kuksa ds tksM+ nksgjs dhfyr rFkk LrEHkksa o gFk


iVfj;ka ,dy dhyfr gksaxs ljsl yxkdjA
[k ;fn [kjknh gqbZ Mksoy
s tksMk+ as okyh mYVh Vksfi;ka LrEHkksa esa yxkbZ
tkrh gSa rks LRkEHk dh yEckbZ Vksfi;ksa dks NksMd
+ j ekih tk;sxhA

137

SECTION 8

SECTION 8 JOINERY
[k.M 8& c<+bZfxjh
NEWEL POSTS, BALUSTERS, ETC.-Contd.....
lksiku LrEHk pkSdh rFkk vkyacu vkfn& tkjh.....
PER CUBIC METRE
08052 Newel posts, wrought, with
square, rounded, chamfered
or
stop, chamfered edges,
mortices for strings and
handrails, sectional area exc. 100

mm x 100 mm and fixed


08053 Ditto, but sectional area n exc
100 mm x 100 mm and ditto

1st class
softwood

1st class
hardwood

izFke Js.kh
uje ydM+h

izFke Js.kh
dBksj ydM+h

Rs.

Rs.

41183.00

69096.70

43412.30

72396.50

izfr ?ku ehVj


08052 xf<+r lksiku LrEHk] oxkZdkj] xksykdkj] i[knkj
;k can i[k fljks ds lkFk] vkoa/kuksa o gFk
iVfj;ksa esa 100 100 feeh ls vf/kd ifjPNsnh
{ks=Qy dh /kqfj;k rFkk LFkkfir
08053 mi;qDZ r fdUrq ifjPNsnh {ks=Qy 100 100
feeh ls vuf/kd] mi;qZDr

NEWEL ENDS & CAPS ETC.

lksiku LRkEHk fljs o Vksih vkfn

EACH

iz R ;s d

08054 Rounded and mitred ends to

tops of newels
08055 Weathered and mitred caps
(with bed moulding under) to
tops of newels and fixed
08056 Turned caps (or pendants) with
ball ornament and fixed to tops
or bottoms of newels (upto 100
mm x 100mm in section) with
glued and dowelled joint
08057 Ditto to newels exc. 100 mm x
100 mm, but n. exc 150 mm x

150 mm in section

72.90

110.70

217.20

342.90

216.70

338.30

360.50

676.70

08054 LRkEHkksa ds 'kh"kZ ds xksy ;k dyeh fljs


08055 LRkEHkksa ds 'kh"kZ ij _rq lg o dyeh Vksih
vUnj lkafpr ijr rFkk LFkkfir djuk
08056 myVh] Vksfi;k ;k izyEch ltkoVh xksys
lfgr LRkEHk ds 'kh"kZ ;k iSanh esa 100 100
feeh rd dh dkV esa ljsl o nks eqga s isp ls
tksM+ yxh lfgr LFkkfir
08057 mi;qZDr] fdUrq dkV esa 100 100 feeh ls
vf/kd fdUrq 150 150 feeh ls vuf/kd
rFkk] mi;qZDr

BALUSTERS
vkya E cu
PER RUNNING METRE

08058 Balusters, square


wrought and fixed,
with ends housed
(square or splay) to
handrails and treads

or strings

1st class softwood

1st class hardwood

izFke Js.kh uje ydM+h

izFke Js.kh dBksj ydM+h

Section n.exc

Section n.exc

dkV vuf/kd

dkV vuf/kd

2525
mm

4040
mm

5050
mm

2525
mm

Rs.

Rs.

Rs.

Rs.

89.40

99.20

178.80

138.30

4040 5050
mm
mm
Rs.

Rs.

157.90 281.50

iz f r ehVj
08058 oxkZdkj x<+s vkyEcu rFkk
fljs pS d ks j ;k <kyw
gFkiVjh rFkk inksa ;k
vkoa/kuksa esa LFkkfir

138

SECTION 8

SECTION 8 JOINERY
[k.M 8& c<+bZfxjh
MISCELLANEOUS
fofo/k & dk;Z
(a) All work shall be wrought unless otherwise described.
(b) The rates allow for fixing (or placing) in position complete, including all cutting of holes and making good,
plugging, etc.
(c) Brackets or other supports shall be measured separately.

PER SQUARE METRE


08059 Draining board of 1 st class
hardwood, 25 mm thick, as
described in SSR Part I
Section 8 Clause 8.30 (area of
top of board only to be

measured)
08060 Aluminium sheet covering to
draining board lmm thick
fixed with aluminum alloy

screws

x cSzfdV ;k vU; lgkjs izFkd ekis tk;saxsA

S&F

Fixing
only

Add if in
repairs

Resecuring
only

izfr oxZ ehVj

vk- o
LFkk-

LFkkiu
dsoy

tksM+s ;fn
ejEer esa

iqu%LFkkiu
dsoy

Rs.
119.50

Rs.
88.60

08059 fu"dklu cksM]Z izFke Js.kh ydM+h


ds] 25 feeh eksV]s TkSl]s ,l ,l
vkj Hkkx&1 [kaM 8 /kkjk 8-30 esa
of.kZr gS( dsoy cksMZ ds 'kh"kZ dk
{ks= ekik tk;sxk
08060 fu"dklu cksMZ ds vkPNknu] 1 feeh
vY;wefq u;e pknj ds vYeqfu;e
feJ /kkrq ds ispksa ls LFkkfir

Rs.
Rs.
2572.40 262.70

EACH

S&F

vk- o LFkk08061 Small fittings such as


brackets of any type, latch
and hinge blocks, shaped
door and window stops
and the like, including all
necessary' labours; articles
n exc 200 cu. cm each

d lHkh dk;Z tc rd fd vU;Fkk of.kZr u gks x<+s gq;s gksaxsA


[k ;g njs]a lHkh Nsnksa dh dVkbZ o ifj"d`fr] ca/kkbZ lfgr LoLFkku]
LFkkiuk ;k fcNkbZ laiw.kZ dh vuqefr nsrh gSA

Fixing Add if Resecuring


only softin
only
wood or repairs
dsoy
hardwood tksMsa+
iqu%

dsoy
;fn
LFkkiu
ejEer
izFke Js.kh izFke Js.kh
uje o
esa
uje ydM+h dBksj ydM+h dBksj ydM+h
1st class 1st class
softwood hardwood

LFkkiu

Rs.

Rs.

Rs.

Rs.

Rs.

22.60

34.90

8.20

1.50

2.90

32.40

52.90

14.00

2.90

5.80

4.70

6.40

1.20

0.60

0.90

08062 Ditto but exc 200 cu. cm


and n exc 500 cu. cm

08063 Ditto exc 500 cu. cm and n

exc 1000 cu cm

08064 Ditto exc 1000 cu. cm and

n exc 5000 cu cm
08065 Wood turn-buckles 50 mm
x 25 mm x 15 mm thick, cut
to shape, fixed with
screws

iz R ;s d

08061 NksVs miLdkj tSls] fdlh


Hkh izdkj ds cSfz dV] daM
q ho
dCtk [kaM] lqx<+ njokts
o f[kM+fd;ksa ds LVki rFkk
leku lHkh vko';d Je
lfgr( lHkh oLrq;sa 200
?kuls e h izR;s d ls
vuf/kd dh
08062 mi;qDZ r] fdUrq 200 ?klseh
ls vf/kd] fdUrq 500 ?klseh
ls vuf/kd
08063 mi;qDZ r] fdUrq 500 ?klseh
ls vf/kd] fdUrq 1000 ?klSeh
ls vuf/kd
08064 mi;qDZ r] fdUrq 1000 ?klSeh
ls vf/kd] fdUrq 5000 ?klSeh
ls vuf/kd
08065 50 25 15 feeh eksVh
ydM+h dkV dj cuh isp
yxh mHk;d"khZ f<ofj;ka

139

SECTION 8

SECTION 8 JOINERY
[k.M 8& c<+bZfxjh
MISCELLANEOUS-Contd...
fofo/k dk;Z tkjh...
S&F

vk- o LFkk08066 Boxes for toilet paper,


size 200 mm x 75 mm
x 120 mm (inside), out
of 15 mm thick
dovetailed boarding
with rounded edges
on top, raised back
with 15mm dia hole

and fixed

Fixing Add if Resecuring


only softin
only
wood or repairs
dsoy
hardwood tksMsa+
iqu%

dsoy
;fn
LFkkiu
ejEer
izFke Js.kh izFke Js.kh
uje o
uje ydM+h dBksj ydM+h dBksj ydM+h
1st class 1st class
softwood hardwood

LFkkiu

Rs.

Rs.

Rs.

Rs.

Rs.

84.80

133.50

11.70

2.90

2.90

iz f r ehVj
08067 ljslh tksM+] vkMs thHkh]
x<+kbZ 50 feeh vuf/kd ds
tc vU;Fkk O;oLFkk u gks

PER RUNNING METRE


08067 Cross
tonguing
including ploughing
and gluing joints, n
exc 50 mm thick
(when not otherwise

provided for)

08066 izlk/ku dkxt j[kus dk


fMCck] 200 feeh 75 feeh
120 feeh vUnj ls esa]
15 feeh eksVs diksy iqaNh
r[rs ls cus ftlds +ij
ds fdukjs xksy fd;s gq;s gksa
ihB ls mBk gqvk rFkk 15
feeh O;kl ds fNnz lfgr
rFkk LFkkfir

23.30

35.00

11.70

JOBBING WORK GENERALLY


lkekU;r% Qq V dj dk;Z
(a) The rates below (unless otherwise stated) include for labour
in fixing or taking down and refixing, together with all
accessory materials such as nails, screws, wedges, plugs,
glue, putty, etc. and also for plugging up old screw holes,
etc., and for painting one coat on edges of shutters of doors,
windows, etc. eased or refitted.

d uhps dh njksa esa Je lefgr gSa tSls tc rd vU;Fkk dfFkr u


gks fLFkj djus] ;k m[kkM+dj fQj lHkh lkexzh lfgr tSls dhysa
isp] es[ks]a MkVs]a ljsl] ih rFkk iqjkus ispksa vkfn ds fNnzkas dks Hkjuk
Hkh rFkk] lgt fd;s ;k nksckjk yxk;s x;s njokts f[kM+fd;ksa ds
dikVksa ds fdukjksa ij jksxu dh ,d ijr yxkus gsrAq

(b) Any cutting and pinning, making good to walls, and


finishings (except where mentioned and included in the
item) shall be measured under the appropriate items in the
respective sections, but opening joints of brickwork or
masonry for the reception of plugs is included in the jobbing
work rates.

[k dVkbZ o fiu ca/ku] nhokjksa dh ifj"d`fr;ksa dks Bhd djus ds


dk;Z dks flok; tgka dfFkr gksa vkSj en esa 'kkfey gks ds dk;ksZ
dks lacfU/kr [kaM esa mi;qDZ Rk enksa ds vUrxZr ekik tk;sxk] fdUrq
MkVsa yxkus ds fy;s nhokjksa ;k fpukbZ esa tksM+ [kksyuk] QqVdj
dk;Z dh njksa esa 'kkfey gSA
x *iqu%jf{kr* dh vfHkO;fDr esa] miLdj vkfn dks dluk tks dqN
<hys gks x;s gksa vkSj fudkys fcuk idM+ iV~Vh ;k MkVksa ls ftUgsa
Bhd fd;k tk ldrk gks] dk izko/kku gSaA

(c) The term Resecure provides for securing fittings, etc.


which have become partly loosened but which can be secured
with holdfasts, plugs, etc. without taking down.
(d) The expression ease and adjust applies to hinged or
sliding shutters of windows, doors, skylights, etc.
(e) The rates for Taking down include for clearing out nails,
etc. and removal from one room to another in the same
building but does not include removal of the items of builders
hardware.

?k *m[kkM+uk* dh njksa es dhy vkfn fudkyuk o mlh Hkou esa ,d


dejs ls nwljs dejs esa ys tkuk 'kkfey gS fdUrq ekhuh
mRiknu miknku ys tkuk 'kkfey ugha gSA

140

SECTION 8

SECTION 8 JOINERY
[k.M 8& c<+bZfxjh
JOBBING WORK GENERALLY-Contd....
QqVdj dk;Z lkekU;r% tkjh....
(f) The rates for Refixing in other openings include for cutting
to size and fitting.
(g) The rates for Removing to Store shall be applicable also to
removing for reuse in another building in the same camp or
Cantonment.
(h) Unless otherwise stated, the rates shall apply to shutters and
chowkats of any species of wood.
(j) In the case of chowkhats or frames, the measurements shall be
taken overall flat on one side.

p *vU; fcojksa esa iqu% LFkkiu* dh njs]a esa dkVuk o LFkkiu djuk
'kkfey gSA
N *Hk.Mkj esa igqapkuk dh njsa] nksckjk iz;ksx djus ds fy;s mlh
dSai ;k Nkouh esa nwljs Hkou esa igqapkus ij Hkh ykxw gksrh gSaA
t tc rd fd vU;Fkk dfFkr u gks ;g njsa fdlh Hkh izdkj dh
ydM+h ds dikV o pkS[kVksa ij ykxw gksaxhA
> pkS[kVksa vkSj Qzseksa ds ekeys esa eki laiw.kZ likV Ykh tk;sxhA

REPAIRS TO CHOWKHATS OR FRAMES


pkS[kVksa o seksa dh ejEer
EACH

08068 Chowkhats
or
frames not exc. 1.5

sq. m each
08069 Ditto but with
shutters (without
taking off shutters
from the frames)
08070 Add to items 08068
&
08069
for
architraves, soffits,
linings, window

boards, etc.
08071 Chowkhats
or
frames exc 1.5 sq. m
but n exc 4 sq. m

each
08072 Ditto but with
shutters (without
taking off shutters
from the frame)
08073 Add items 08071 &
08072
for
architraves, soffits,
linings, window

boards, etc.

Resecuring
without
taking
down

Refixing in

iqu% LFkkiu

Taking Removing
down to or from
fudkyuk Store

Same
opening

Other
opening

fcuk fudkys
dluk

ogh focj

vU; focj

Rs.

Rs.

Rs.

Rs.

Rs.

36.00

94.50

161.80

58.80

17.90

56.40

124.30

210.80

HkaMkj esa
;k ls mBkuk

93.10

23.80

17.80

47.60

77.10

29.40

11.90

44.80

119.70

205.00

73.50

23.80

71.30

29.90

154.00

60.70

263.40

98.90

iz R ;s s d

117.60

39.20

08068 pkS[kV ;k se izR;sd 1-5


oeh ls vuf/kd
08069 mi;q Z D r] fdUrq dikV
lfgr dikVksa dks se esa
ls fcuk fudkys
08070 tksMsa] 08068 vkSj 08069
enksa es]a izLrjikn] v/k%Lry]
vLrj] f[kM+dh r[rs vkfn
ds fy;s
08071 pkS[kV ;k se izR;sd 1-5
oeh ls vf/kd fdUrq 4 oeh ls
vuf/kd

29.80

08072 mi;qDZ r] fdUrq dikV lfgr


dikVks a dks s e es a
l fcuk fudkys

15.90

08073 tksM+sa] 08071 vkSj 08072


enks a es a ] iz L Rkj ikn]
v/kLry] vLrj] f[kM+dh
r[rs vkfn ds fy;s

141

SECTION 8

SECTION 8 JOINERY
[k.M 8& c<+bZfxjh
REPAIRS TO SHUTTERS
dikVksa dh ejEer
*iqu LFkkiu* dh njksa esa mrkjuk] lgt o lek;kstu djuk rFkk
vuqi;ksxh ispksa dks cnyus lfgr vko';drkuqlkj bekjrh e'khuh
miknuksa dks iqu% yxkuk 'kkfey gSA ;fn fo'ks"k:i ls vkns'k fn;k
x;k gS rks e'khuh miknku dh oLrqvksa dk Hkqxrku **dsoy vkiwfk dh
njksa ij gksxkA

The item for 'refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including
renewal of unserviceable screws, etc. Renewal of builder's hardware articles, if specially ordered, shall be paid for at 'supplied
only' rates

PER LEAF

08074 Shutters of any


description n exc 1

sq. m each
08075 Ditto but exc 1 sq. m
and n exc 2 sq. m

each
08076 Ditto but exc 2 sq. m

each

Resecuring
or easing &
adjusting
without
taking down

Refixing in

esa iqu% LFkkiu


Same
opening

Other
opening

Taking Removing
down to or from
fudyuk
Store

iz f r iYyk

HkaMkj esa ;k
ls gVkuk

ogh focj vU; focj

iqu% fLFkj] lgt


;kstuk] fcuk
mrkjs
Rs.

Rs.

Rs.

Rs.

Rs.

17.50

46.90

79.20

14.70

23.80

35.00

67.30

151.90

29.40

37.70

46.60

96.70

186.20

50.00

50.00

08074 fdlh Hkh fdLe ds dikV


izR;sd 1 oeh ls vuf/kd
08075 mi;qDZ r] fdUrq 1 oeh ls vf/kd
o 2 oeh ls vuf/kd
08076 mi;qDZ r] fdUrq izR;sd 2 oeh
ls vf/kd
izfr oxZ ehVj

PER SQUARE METRE


08077 Wall
panelling

and similar work

19.60

08077 nhokj fnYyscna h rFkk leku


dk;Z

11.90

MISCELLANEOUS REPAIRS
feyhtq y h ejEers a
EACH
08078 Pieces, small let in for making
good where hinges, etc. have
been removed from chowkhals
or frames, joinery, etc.
including painting or oiling to

match, if required

12.00

iz R ;s d
08078 ydM+h ds VqdM+]s NksVs fNUnzkas esa yxkus ds
izFke Js.kh dBksj
fy;s tks pkS[kVksa ;k seks] tksM+ dk;Z
ydM+h
vkfn ls dCts vkfn fudkyus ls gks tkrs
Rs.
gS- feyku ds fy;s ;fn vko';d gks rks
jksxu ;k nzO; dh ijr yxkus lfgr
16.70

14.50

iz f r ehVj
08079 'kh'ksnkj ;k tkyhnkj c<+bx
Z hjh uohuhdj.k
dk;ksZa ds fy;s ehVjSl lfgr lh/kh fdlh
eki dh xksV Qf;ka rFkk iqjkuh QfV~V;ksa
dks Hk.Mkj esa igaqpkuk

1st class softwood

izFke Js.kh uje


ydM+h
Rs.

1st class hardwood

PER RUNNING METRE


08079 Beads, straight (any size) for
glazed or gauzed joinery,
renewed, including mitres etc..
and removing old beads to

Store

22.10

142

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
SUB-SECTION 8B
SOLID PVC JOINERY
mi&[kaM 8Ckh Bksl ih oh lh c<+bZfxjh
8B.1
DEFINITIONS
8B.1.1 PVC SHEET/ PLAIN COLOUR PVC SHEET
PVC sheet means FREE FOAM RIGID PVC SHEETS made out of PVC Resin (suspension grade) blended with
suitable chemicals and additives. The sheets shall be made by extrusion process and foamed using organic
blowing agents. The sheets will be self coloured in plain shades by blending suitable pigments with PVC
resin. The sheets will have silky matt surface finish free from any blistering, colour blots, creasing, pin holes
etc.. The density & thickness of the sheets shall be as under:THICKNESS
in mm

TOLERANCE
in mm

DENSITY
Kg/m3

1 mm

0.85-1.15mm

Min. 780

1.5mm

1.35-1.65mm

Min. 750

2mm

1.80-2.20mm

Min. 700

3 mm

2.75-3.25mm

Min. 700

5 mm

4.65-5.35mm

Min. 600

8B.1.2

Printed PVC Sheets


PVC Sheets, as defined in 8B.1.1, screen printed with suitable designs using Glossy PVC Ink.

8B.1.3

Prelam PVC Sheets


PVC Sheets, as defined in 8B. 1.1, laminated under pressure and temperature with hotstamping foil of
various aesthetic veneer-like appearance. The thickness of hot stamping foil shall be 30 micron with tolerance
limit + 10%. Hot stamping lamination shall be on one side or both sides in PVC sheets as indicated. When
lamination is done on one side, the other side will have either white or Ivory colour.

8B.1.4

Embossed PVC Sheets


Prelam PVC Sheets, as defined in 8B.1.3, with designs i.e. intricate lattice work combined with scroll work
and geometrical patterns, embossed to depth ranging from 4mm to 6mm by vacuum thermoforming process.

8B.1.5

Moulded PVC Sheets


PVC sheet as defined in 8B.1.1 or 8B.1.3, vacuum thermoformed to give raised panel i.e. two panel, four
panel or six panel look with moulding depth ranging from 12mm to 16mm.

8B.1.5.1 3-D Wood Grain Moulded PVC Sheets


PVC sheet as defined in 8B 1.1 with additional 3-D wood like effect suitably painted using Polyurethane
paint, vacuum thermoformed to give raised panel i.e. two panel, four panel or six panel look with moulding
depth ranging from 12mm to 16mm.
8B.1.1.6 Solvent Cement
A composite organic chemical comprising of Cyclohexanone, Tetrahydro flurance (THF), Methyl Ethyl
Ketone (MEK) etc. in transparent liquid state, generally used for joining PVC Pipes. The solvent cement
when applied on PVC sheets dissolves its surface, bonding it to the other PVC sheet permanently. The date
of manufacture of solvent cement shall not be more than 6 month.
8B.1.7

PVC Sandwich Panel


PVC Sandwich Panel shall consist of Expanded Poly Styrene (EPS) conforming to IS 4671, of density 32 Kg/
mtr3 (tolerance limit+15%) flame retardant (TF) grade of desired thickness (mm) sandwiched between two
PVC sheets of 1mm, 1.5mm, 2mm or 4mm thickness using thermosetting adhesive.

143

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
8B.1.8 PVC Insulation Panel
PVC Insulation Panel shall consist of Expanded Poly Styrene (EPS) conforming to IS 4671 of minimum
density 15kg/m3 flame retardant (TF) grade of desired thickness (mm) stuck to PVC sheet of 1mm, 1.5mm,
2mm or 5mm thickness using thermosetting adhesive on one side.
8B.1.9 PVC Sheet Fillet for Wall Panelling
5mm thick & 35mm width PVC sheets with U shape grooved of 2mm depth in the center. The purpose of the
groove is that the head of the screw used to fix the fillet to the wall sinks into it so as to make the surface of the
fillet in plain.
8B.1.10 M.S. Square Tube
M.S. Square tube of size 19mm x 19mm & 15mm x 15mm of 19 gauge of required length with coat of steel
primer.
8B.1.11 M.S. Angle
M.S. Angle of size 35mm x 35mm x 5mm of required length with coat of steel primer.
8B.1.12 EPDM Rubber Gasket
EPDM Rubber gasket with bulb-type profile used to make Doors & Windows air tight.
8B.1.13 Decorative PVC Beading
L type (900) Decorative PVC Beading of size 10mm x 10mm with wood moulding design.
8B.2

FACTORY MADE SOLID PVC DOOR SHUTTERS

8B.2.1 FACTORY MADE SOLID PANEL PVC DOOR SHUTTER


30 mm thick Factory Made Solid Panel PVC Door Shutter consisting of frame made out of M.S. tubes of 19mm
x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall be covered with 5mm thick heat
moulded PVC sheet C channel having a 5mm thick PVC sheet strip of 20mm width stuck inside with solvent
cement, forming stiles, and 5mm thick PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm
(5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick
PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with PVC sheet beading, and joined
together with solvent cement adhesive etc. complete as per direction of Engineer-in-charge, manufacturers
instructions and drawing. The width of stiles & rails will be in proportion to the width of the door shutter as
detailed below :
Door width
(in feet)

Stiles Size

Rails Size

Remark

Feet

mm

mm

1.5' up to 2'

50mm

50mm

More than 2up to 2.5

50mm

75mm

More than 2.5 up to 3

75mm

100mm

Gap insert of 15mm to be provided

More than 3'

100mm

125mm

between stiles and rails & panel.

For doors of sizes larger than 17.5sq.ft. an additional 15mm x 15mm, 19gauge M.S. square tube shall be welded
to the M.S. frame below the top rail square tube keeping a gap of 50mm between the two M.S. square tubes. In the
case of double leaved shutters the meeting stiles shall be rebated 20mm as shown on drawing. The rebating
shall be square, as directed.

144

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
Factory Made Solid Panel PVC Door Shutters shall conform to the below mentioned permissible limit as per
testing methods provided in IS 4020.
S.No.

Test

Permissible Limit

01

Dimensions and squareness

Width 3 mm
Height + 3 mm
Difference in Diagonals : Not more than 3 mm

02

General flatness test

No twisting cupping or warping shall be observed

03

Local Planeness test

Depression on all 10 points at the panel areas shall


be less than 0.5mm

04

Impact indentation test (Steel ball impact test)

Indentations shall be less than 0.3mm

05

Edge loading test

Initial max. deflection shall not be more than 5mm


Residual deflection shall not be more than 0.5mm

06

Shock resistance test

No visible damage shall be observed

07

Buckling test

Initial deflection shall not be greater than 90mm.


Residual deformation after 15 minutes of
unloading shall not be greater than 5mm.

08

Slamming test

No visible damages shall be observed to any part


of the door.

09

Misuse test

No permanent deformation of the fixing or any


other part of the door shutter in hindering its normal
working shall be observed

10

Screw withdrawal resistance test.

Face : 1400N, Edge: 1500N.

8B.2.2 Printed Solid Panel PVC Door Shutters


Solid Panel PVC Door as in 8B.2.1 but made using Printed PVC sheet and panel to be fitted in the M.S. frame
welded / sealed to the stiles & rails with 5mm thick x 15mm wide PVC sheet beading on inner side of panel and
decorative PVC beading of 10mm x 10mm (900) is used on outer side of panel.
8B.2.3 Single Side Prelam Solid Panel PVC Door Shutter
Solid Panel PVC Door as in 8B.2.1 but made using Prelam PVC sheet and Single Side Prelam Panel to be fitted in
the M.S. frame & sealed directly without beading to the front (prelam side) stiles and rails (which shall have a 5mm 450
bent portion) and sealed to the back (Plain colour) stiles and rails (which shall have a 10mm 900 bent portion) using
2 nos. 15mm wide x 5mm thick PVC sheet beading inside the 900 bent beading.
8B.2.4 Both Side Prelam Solid Panel PVC Door Shutter
Solid Panel PVC Door as in 8B.2.1 but made using Prelam PVC sheet and stiles & rails shall be extended by 20mm
which shall be tapered in 450 angle on either side. 5mm+2mm thick x 15mm wide PVC sheet beading on inner side,
and joined together with solvent cement adhesive etc.
8B.2.5 Fully Glazed Solid PVC Door Shutter
Solid Panel PVC Door as in 8B.2.1 but with glass panel instead of 5mm PVC sheet panel. Glass pane will be fitted
externally in the clear space available between the stiles & rails and fixed with PVC sheet beading on one side and
Decorative PVC beading on the other side will be nailed on the rails and stiles so that the decorative beading can be
removed when required for replacement of broken glass pane.

145

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
8B.2.6 Partly Glazed Solid Panel PVC Door Shutter
Solid Panel PVC Door as in 8B.2.1 but the upper panel will be glazed fitted externally in the clear space available
between the stiles & rails fixed with PVC sheet / decorative beading & lower panel will be PVC Panel.
8B.2.7 Wire Gauzed Solid PVC Door Shutters
Solid Panel PVC Door as in 8B.2.1 but panel will be of G.I. wire gauze. The wire gauze shall be wrapped on an
additional 8 mm square M.S. Solid tube and this tube shall be welded to 19mm x 19mm M.S. tubes. The G.I. wire gauge
shall be stretched to tighten firmly.
8B.2.8 Fully Louvred Solid PVC Doors Shutters
Solid Panel PVC Door as in 8B.2.1 but with louvred panel instead of 5mm PVC sheet panel. Louvred panel shall
consist of 25mm thick heat bent PVC sheet C channel with a 5mm thick PVC sheet of 10mm width stuck inside, on all
four sides. Slanted slots shall be cut at 450 angle in both the vertical C Channels at an interval of 100mm. 5mm thick
PVC sheet of width 25mm of suitable length shall be inserted in the slant cut slots and fixed with solvent cement.
If the width of Solid PVC louvre door shutter is more then 2 feet (610mm) an additional vertical PVC memeber of
width 25mm and 15mm thickness with slots cut at 45 angle shall be fixed with solvent cement in the center of the
louvred panel for support & rigidity.
8B.3 FACTORY MADE SOLID PVC DOOR FRAMES
8B.3.1 Solid Single PVC Door Frame
Solid PVC Door Frame of the size 50 x 47mm made out of 5mm PVC sheet. The door profiles are to be reinforced
with 19xl9mm M.S. Square tube. EPDM rubber gasket weather seal to be provided through out the frame. The profile
shall be mitre cut at two corners and joined by inserting 2nos. of 150mm long brackets of 15x15mm M.S. square tube
inside the 19mm x 19mm M.S. square tube and suitably screwed.
8B.3.2 Solid PVC Double Door Frame
Solid PVC Double door frame of size 50mm x 95mm made by joining 3 nos. heat bent PVC Sheet C Channel of
5mm thickness of sizes 35mm x 30mm x 25mm & 40mm x 35mm x 40mm & 25mm x 30mm x 35mm using solvent
cement. The two side C Channel shall be reinforced with M.S. tube of size 19mm x 19mm. All the three C channel
Shall be fixed to flat base of 5mm PVC sheet with solvent cement. The profile shall be mitre cut at two corners and
joined by inserting 4nos. 150mm long brackets of 15x15mm M.S. square tube inside the 19mm x 19mm square tubes &
remaining each of them with four screws as indicated in the drawing.
8B.4 FACTORY MADE SOLID PVC MOULDED DOOR SHUTTERS
8B.4.1 Particle Board Core Solid PVC Moulded Door Shutter
28 to 30mm thick factory made Solid PVC Moulded Door shutter with 2, 4, or 6 raised panel design with solid core
of particle board of 24mm thick (12mm x 2). The particle board shall be lipped with 25mm thick baton made from PVC
sheets on the stile where hinges are to be fitted. On the three other sides the lipping shall be of 15mm thick PVC baton.
2mm thick Moulded PVC sheet shall be stuck on the front face of the particle board suitable prepared to accept the
moulded design and 2mm PVC sheet shall be stuck on the back face of the particle board with thermosetting adhesive.
The 2mm thick PVC sheets shall be stuck with lipping by using solvent cement.
8B.4.2 EPS Core Solid PVC Moulded PVC Door Shutter
28 to 30mm thick factory made EPS Core Solid PVC Moulded Door Shutter consisting of frame made out of M.S.
Tube. The core panel shall consist of 25mm thick High Density EPS conforming to IS 4671, routed with design,
sandwiched in between 2mm thick Moulded PVC sheet on one face and 2mm PVC sheet on the other side. The door on
all the edges to be sealed with lipping of 10mm (5mm x2) thick x 25mm wide PVC sheet for three sides & 60mm wide
PVC sheet for lock side. The lipping shall be bonded to the 2mm Moulded / Plain PVC sheet with solvent cement.

146

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
8.B.5 PVC Sheet Cladding
PVC sheet shall be stuck using rubber based adhesive for cladding. PVC sheet may be heat bent i.e. lipping to
cover the edges of plywood / flush door shutter.
8.B.6 Solid PVC Wall Lining
Solid PVC Wall Lining shall consist of PVC sheet stuck with solvent cement on PVC sheet panelling fillets as per
direction of Engineer-in-Charge, manufacturers instruction & drawing. Rectangular or circular pillars or other insets
in the wall shall be covered using heat bent PVC sheet to ensure heat bending of the PVC sheet at the required angle,
suitable groove shall be cuts in the PVC sheet if required.Two PVC lining sheets shall be stuck adjacent to each other
after leaving a gap of 2mm. If so desired strips of 5mm thick PVC sheet of width 75mm feathered at the edges can be
stuck at the places where two PVC sheets are joined, using solvent cement.
8.B.7 Insulated PVC Wall Lining
Insulated PVC wall linings shall consist of PVC Insulated panels having wall thickness of 2mm PVC sheet and
the desired thickness of EPS (dependent on the insulation required) screwed into the wall using screws of adequate
length.The screws shall be placed at a distance of 150mm and shall be 25mm from the edge of the insulated panel on
all from sides of the panel. Strips of 5mm thick PVC sheet of width 75mm feathered at the edges shall be stuck at the
places where two panels are joined, so as to cover the screws of both the panels, using solvent cement. 900 heat bent
strips of 5mm thick PVC sheets of width 75mm x 75mm feathered at the edges shall be stuck at wall joints/pillars etc.
8.B.8 Solid PVC Partitions
Solid PVC Partitions consist of PVC sandwich panel of suitable thickness placed in M.S. angle frame work and
fixed inside C Channel and feathered strips made from 5mm thick PVC sheets, as indicated in detailed drawings.M.S.
angle between the floor & ceiling height with anchor bolts at an interval of 1220mm or as mentioned in the drawing
horizontal angles. In between two M.S. angles PVC sheet heat bent C channel of size 100mm x 50mm with feathered
edges shall be fixed with screw on the floor.In between two M.S. angles PVC sheet heat bent C channel of size 75mm
x 50mm with feathered edges shall be fixed with screw in the ceiling.The first & last M.S. angle should be erected such
that it is inside a PVC sheet heat bent C channel of size 75mm x 50mm which has been screwed on to the walls.PVC
sandwich Panels shall be inserted in the PVC sheet C channel fixed at ground floor & ceiling and shall be stuck by
using solvent cement. In between adjoining EPS Sandwiched PVC Partitions panel 5mm thick x 75mm width PVC
sheet feathered at edges shall be stuck on front & back face using solvent cement as indicated in the detailed drawing.
8.B.9 Solid PVC Insulation Panel For False Ceiling
Solid PVC insulation panels having wall thickness of 1mm PVC sheet and EPS of desired thickness depending
on insulation required shall be placed in false ceiling grid made of Aluminium/G.I./M.S. as indicated in detailed
drawing.
8.B.10 Solid PVC Joinery items shall be of approved makes.

147

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
FACTORY MADE SOLID PVC PANEL, GLAZED, WIRE GAUGED, LOUVRE DOOR
SHUTTERS
Hinges, Glass or wire cloth in panels shall be measured
separately.
PER SQUARE METRE
08080 Factory made solid panel PVC door shutter
30 mm thick (style) consisting of frame
made out of M.S. tubes for top & bottom
rails. M.S. frame shall be covered with heat
moulded plain colour PVC C channel
having a PVC sheet strip of 20mm width
stuck inside with solvent cement for stiles
and plain colour PVC sheets for top rail,
lock rail & bottom rail on either side & as
gap insert for top rail & bottom rail;
Panelling of plain colour PVC sheet to be
fitted in the M.S. frame welded / sealed to
the stiles & rails with suitable PVC sheet
beading, and joined together with solvent
cement, suppling & fixing in the frame at
site as per specification & drawing.

08081 All as per item no. 08080 but wood grain


printed PVC sheet used instead of Plain
colour PVC sheet & 5mm thick x15mm
wide PVC sheet beading used inside
stiles and rails and decorative PVC
beading of 10mm x 10mm (900 ) used
instead of exposed portion of PVC sheet

beading.
08082 All as per item no.08080 but Single Side
Prelam PVC sheet used instead of Plain
colour PVC sheet and stile & rails
having one side feathered edge and on

other side 10mm 900 bent edge.

dCts] fgYyks esa 'kh'kk ;k rkjh diMk vyx ls ekik tkxkA

S&F
Rs.

2026.70

2232.70

08082

2440.60

08083

2531.40

08085 All as per item no. 08081 but fully glazed


i.e. glass panes used instead of 5mm wood

grain printed PVC sheet panels.

08081

08083 All as per item no.08080 but both side


Prelam PVC sheet used instead of Plain
colour PVC sheet. Stile and rails

feathered at edges
08084 All as per item no. 08080 but fully
glazed i.e. glass panes used instead of

5mm PVC sheet panels.

08080

08084
1916.30

08085
2003.50

izfr oxZ ehVj


dkj[kkus ds cus Bksl iYys ds ih0oh0lh0 njokts ds
dikV 30 feeh0 eksVs LVkby ds] uje yksgs dh
uyh ls cuh mij o uhps dh iVVh okys se ls cuk
gqvk gksukA uje yksgs ds se dh LVkby dks vkap
ls <yh likV jax dh ih0lh0lh0 pSuy ls <dk
tk,xk vkSj 20 eh0eh0 pkSMh ih0oh0lh0 dh pknj
dh iVVh dks vUnj dh rjQ lksyoSUV lhesUV ls
tksMk tk,A likV jax dh ih0oh0lh0 pknj mij dh
iVVh] rkys dh iVVh vkSj uhps dh iVVh ds gj
rjQ o mij iVVh vkSj uhps dh iVVh d
s s [kkyh
txg es yxkb tk,A likV jax dh ih0 ih0 lh0
pknj dh fnYys uje yksgs ds se esa iVjh vkSj ih
ls ih0 ih0 lh0 chfMx ds lkFk cSYM@lhy djuk
gS vkSj lksYoSUV lhesUV ds lkFk tqMk gks fufnZf"Vdj.k
o Mkbax ds vuwlkj vkiwfrZ o lFkiu
lc en 08080 tSlk fdUrq likV jax dh pknj
dh ctk; ydM+h ds d.kksa ls fizV dh xbZ ih oh
lh pknj iz;ksx esa ykuk] iVjh vkSj iVVh esa 15
fe eh pkSM+h ih oh lh pknj dh vUnj ls chfMxa
yxkuk] ih oh lh pknj ds [kqys fgLls dh ctk;
10 fe eh 10 fe eh 90 dh ih oh lh dh
ltkoVh chfMax iz;ksx esa ykukA
lc en 08080 tSlk fduq likV jax dh pknj
dh ctk; vdsyh rjQh izhySe ih oh lh pknj
iz;ksx djuk vkSj iVjh vkSj iVVh ds ,d rjQ
iajo tSlh fdukjs okyh vkSj nwljh rjQ 10 feeh
dk 90 ij eqMk fdukjkA
lc en 08080 tSlk fdUrq nksuks rjQ likV jax
pknj dh ctk; izhySe ih oh lh pknj iz;ksx
djuk iVjh vkSj iVaVh ds fdukjksa dks ijao tSlk
cukukA
lc en 08080 tSlk fdUrq 5 feeh ih oh lh
pknj ds fnYyksa dh ctk; iw.kZ 'kh'ksnkj ;kfu
'kh'ks ds Qyd iz;ksx esa ykukA
lc en 08081 TkSlk fdUrq 5 feeh ydM+h ds d.k
ls fizVa dh xbZ ih oh lh pknj ds fnYyksa dh ctk;
iw.kZ 'kh'ksnkj ;kfu 'kh'ks ds Qyd yxukA

148

SECTION 8

SECTION 8JOINERY
[k.M 8 c<+bZfxjh
izfr oxZ ehVj

PER SQUARE METRE


08086 All as per item no.08082 but fully glazed
i.e. glass panes used instead of 5mm
Single Side Prelam PVC sheet panels
08087 All as per item no.08080 but partly
glazed i.e. upper panel will be glass pane
fitted externally in the clear space & lower
panel will be plain colour PVC sheet
08088 All as per item no. 08081 but partly
glazed i.e. upper panel will be glass
panes fitted externally in the clear space
& lower panel will wood grain printed

PVC sheet panel


08089 All as per item no.08082 but partly
glazed i.e. upper panel will be glass
panes fitted externally in the clear
space & lower panel will be Single Side

Prelam PVC sheets


08090 All as per item no.08083 but partly
glazed i.e. upper panel will be glass
panes fitted externally in the clear
space & lower panel will be Both Side

Prelam PVC sheet


08091 All as per item no. 08080 but wire gauzed
i.e. panel will be of wire gauze in lieu of
PVC sheet panel. The wire gauze shall
be wrapped on an additional square
8mm M.S. Solid tube and this tube shall
be welded to M.S. tubes. The wire gauge
shall be stretched to tighten firmly
08092 All as per item no.08081 but wire gauzed
i.e. panel will be of wire gauze in lieu of
wood grain printed PVC sheet panel. The
wire gauze shall be wrapped on an
additional square 8mm M.S. Solid tube
and this tube shall be welded to M.S.
tubes. The wire gauge shall be stretched

to tighten firmly
08093 All as per item no.08082 but wire gauzed
i.e. panel will be of wire gauze in lieu of
single side prelam PVC sheet panel. The
wire gauze shall be wrapped on an
additional square 8mm M.S. Solid tube
and this tube shall be welded to M.S.
tubes. The wire gauge shall be stretched

to tighten firmly
08094 All as per item no.08080 but Fullv Louvred
i.e. PVC sheet panel shall be louvred.

S&F
Rs.
2118.10

2134.00

2265.30

2373.40

2418.60

1628.40

1691.10

1775.30
2104.00

08086 lc en 08082 tSlk fdUrq 5 fe fe0 ,d rjQh


izhySe ih oh lh pknj ds iYys dh ctk; iwjk
'kh'ksnkj ;kfu 'kh'ks ds Qyd yxkuk
08087 lc en 08080 tSlk fdUrq v'kar 'kh'ksnkj ;kfu
mij okyk fnYYkk Li"V LFkku esa ckgj dh vksj
'kh'ks ds Qyd lsa yxk gksxk vkSj uhps okyk fnYYkk
likV jax dh ih oh lh pknj ls yxk gksxk
08088 lc en 08081 tSlk fdUrq v'kar 'kh'ksnkj ;kfu
mij okyk fnYYkk Li"V :Fkku esa ckgj dh
rjQ 'kh'ks ds Qyd ls yxk gksxk vkSj uhps
okyk fnYYkk ydM+h ds d.k lh fizV dh xbZ ih
oh lh pknj dk Qyd gksxk
08089 lc en 08083 tSlk fdUrq v'kar 'kh'ksnkj ;kfu
mij okyk fnYYkk Li"V LFkku esa ckgj dh rjQ
'kh'ks ds Qyd dk yxk gksxk vkSj uhps okyk
fnYYkk ,d rjQk izhySe ih oh lh pknj dk
gksxkA
08090 lc en 08083 tSlk fdUrq vkar khksnkj ;kfu
mij okyk fnYYkk LiB LFkku es ckgj dh rjQ
khks ds Qyd dk gksxk vkSj uhps okyk fnYYkk
nksuksa rjQ ls izhySe ih oh lh pknj dk gksxkA
08091 lc en 08080 tSlk fdUrq rkjh tkyhnkj ;kfu
fnYYkk ih oh lh pknj dh ctk; rkjh tkyh ds
gksxAs rkjh tkyh dks ,d vfrfjDr 8 feeh oxZ
ueZ yksgs dh Bksl uyh ij cka/kk tk,xk vkSj bl
uyh dks ueZ yksgs dh ufy;ks ls cSYM fd;k
tk,xkA rkjh tkyh dks [khpka tk,xk fLFkj
dlus ds fy,A
08092 lc en 08081 tSlk fdUrq rkjh tkyhnkj ;kfu
fnYYkk ydMh ds d.kksa ls fizV dh gqbZ ih oh lh
pknj dh ctk; rkjh tkyh dk gksxkA rkj tkyh
dks ,d vfrfjDr 8 eh eh oxZ ueZ yksgs dh Bksl
uyh ij cka/kk tk,xk vkSj bl uyh dks ueZ yksgs
dh ufy;ksa ls osYM fd;k tk;XkkA rkjh tkyh dks
fLFkj dlus ds fy, [khpka tk,xkA
08093 lc en 08082 tSlk fdUrq rkjh tkyh ;kfu
fnYYkk ,d rjQ izhySe ih oh lh pknj dh
ctk; rkjh tkyh dk gksxkA rkj tkyh dks ,d
vfrfjDr 8 eh eh oxZ ueZ yksgs dh Bksl uyh
ij ck/kka tk,xk vkSj bl uyh dks uje yksgs dh
ufy;ksa esa oSYM fd;k tk,xkA rkjh tkyh dks
fLFkj dlus ds fy, [khpk tk,xkA
08094 lc en 08080 tSlk fdUrq iw.kZ f>yfeyh ;kfu
ih oh lh pknj dk fiYyk f>yfeyh gksxk

149

SECTION 8

SECTION 8JOINERY
[k.M 8 c<+bZfxjh
FACTORY MADE PVC SOLID PVC DOOR FRAME (CHOWKHAT)

dkj[kkus ds cus ih oh lh Bksl ih oh lh njokts ds se pkS[kV


PER RUNNING METRE

iz f r ehVj

S&F
Rs.

08095 Solid PVC Door Frame of size 50mm x


47mm made out of 5mm plain colour
PVC sheet reinforced with M.S. Square
tube, suppling & fixing in opening as per

specification & drawing


08096 All as per item no.08095 but wood grain
printed PVC sheet used instead of Plain
colour PVC sheet & edges will be painted

to match with printed sheet


08097 All as per item no.08095 but single side
prelam PVC sheet used instead of Plain
colour PVC sheet & edges will be painted

to match with prelam sheet


08098 Solid PVC Double door frame of size
50mm x 95mm made out of 5mm Plain
colour PVC sheet reinforced with M.S.
tube, suppling & fixing in opening as per

specification & drawing


08099 All as per item no.08098 but wood grain
printed PVC sheet used instead of Plain

colour PVC sheet


08100 All as per item no.08098 but single side
prelam PVC sheet used instead of Plain

colour PVC sheet

08095 njoktksa ds Bksl ih oh lh se 50 fe eh 47


fe eh vkdkj ds] 5 eh eh ih oh lh pknj ls
cuk uje yksgs dh oxkZdkj uyh ls izcyu]
eks/kksa esa fufnZ"Vdj.k ,oa Mkabx ds vuqlkj
vkiwfkZ ,oa LFkkiu
08096 lc en 08095 tSlk fdUrq likV jax dh ckgj dh
ctk; ydMh ds d.kksa lh fizV dh gqbZ ih oh lh
pknj iz;ksx esa ykuk vkSj fizVa dh gqbZ pknj ls esy
feykus ds fy, fdukjksa dks jksxu fd;k tk,xk
08097 lc en 08095 tSlk fdUrq likV jax dh
pknj ,d rjQh izhySe pknj iz;ksx esa ykuk
vkSj izhySe pknj ls esy feykus ds fy,
fdukjksa dks jksxu fd;k tk,xk
08098 njoktksa ds Bksl ih oh lh nksgjs se 50 fe eh
95 eh eh vkdkj ds] 5 feeh ih oh lh pknj
ls cuk uje yksgs dh oxkZdkj uyh ls izcyu]
eks?kksa esa fufnZ"Vdj.k ,d Mkbax ds vuqlkj
vkiwfrZ ,oa LFkkiu
08099 lc en 08098 tSlk fdUrq likV jax dh
pknj dh ctk; ydMh ds d.kksa lh fizaV dh
gqbZ ih oh lh pknj iz;ksx es ykuk
08100 lc en 08098 tSlk fdUrq likV jax dh pknj dh
ctk; ,d rjQh izhySe ih oh lh pknj iz;ksx esa ykuk

335.30

347.30

366.70

400.40

458.20

496.80

FACTORY MADE SOLID PVC MOULDED DOOR SHUTTERS

dkj[kkus ds cus ih oh lh lfpar njokts ds dikV


izfr oXkZ ehVj

PER SQUARE METRE


08101

08102

08103

Factory Made Solid PVC Moulded


Door Shutter, 28 to 30mm thick
(stiles), with 2, 4, or 6 raised panel
design with 2mm thick Moulded
PVC Sheet on the front face &
2mm plain colour PVC sheet on
back face, supplying & fixing in
frame at site as per specification

& drawing
All as per item no. 08101 but
2mm thick Moulded Prelam
PVC Sheet on the front face &
2mm Plain colour PVC Sheet

on back face
All as per item no. 08101 but
2mm thick Moulded Prelam
PVC Sheet on the front face &
2mm prelam PVC Sheet on

back face

S&F
With Particle
Board Core

With Wood
free EPS

Rs.

Rs.

2421.30

2250.30

2529.60

2371.00

2702.40

2556.10

08101 dkj[kkus ds cus Bksl ih oh lh lkfpar


njoktksa s ds dikV] 28 ls 30 fe eh eksVkbZ
iVVh 2]4 ;k 6 ds mHkjs gq, fnYyksa tks fd
2 fe eh eksVh lkafpr ih oh lh pknj ls vkxs
dk fMtkbu o 2 fe eh eksVh likV jax dh
ih oh lh pknj ls ihNs dk fMtkbu vkiwfRkZ
o lhiu se ds vUnj dk;Z LFkku ij o

fufnZf"Vdj.k o Mkbax ds vuqlkj


0 8 1 0 2 lc en 08101 tSlk fdUrq vkxs dh
rjQ 2 fe eh lkafpr izhySe ih oh lh
pknj vkSj ihNs dh rjQ 2 fe eh ih
oh lh pknj

0 8 1 0 3 lc en 08101 tSlk fdUrq 2feeh lkafpr


ih oh lh izhySe pknj vkXks dh rjQ
vkSj 2 feeh izhySe pknj ihNs dh rjQ

150

SECTION 8

SECTION 8JOINERY
[k.M 8 c<+bZfxjh
FACTORY MADE PVC MOULDED DOOR SHUTTER

dkj[kkus ds cus ih oh lh esa <ys njokts ds dikV


S&F

PER SQUARE METRE


08104 All as per item no. 08101 but 2mm
thick 3D wood grain Moulded
PVC Sheet Polyurethane painted
on the front face & 2mm Plain
colour PVC Sheet on back face

With Particle
Board Core

With Wood
free EPS

Rs.

Rs.

2527.90

2403.60

2700.60

2556.10

08105 All as per item no. 08101 but 2mm


thick 3D wood grain Moulded
PVC Sheet Polyurethane painted
on the front face & 2mm prelam

PVC Sheet on back face

izfr oXkZ ehVj


08104 lc en 08101 tSlk fdUrq vkxs
dh rjQ 2 fe eh 3 Mh ydMh
ds d.kksa lh lkfpar ih oh lh
pknj tks fd iksY;wFksuZ jksxu dh
gqbZ gks] 2 feeh ih oh lh pknj
ihNs dh rjQ
08105 lc en 08101 tSlk fdUrq vkxs dh
rjQ 2 fe eh 3 Mh ydMh ds d.kksa
dh lkfpar ih oh lh pknj tks fd
iksYiqFksuZ jksxu dh gqbZ gks] 2 fe eh
izhYkSe ih oh lh pknj ihNs dh rjQ

PVC SHEET CLADDING MATERIAL


PER SQUARE METRE
08106 Plain colour PVC sheet fixed
or laid on to flush doors by
using rubber based adhesive,
supplying & fixing at site as

per specification
08107 All as per item no. 08106, but
wood grain printed PVC
sheet used instead of Plain

colour PVC sheet


08108 All as per item no. 08106, but
single side prelam PVC sheet
used instead of Plain colour

PVC sheet
08109 All as per item no. 08106, but
single side prelam embossed
by thermoforming PVC sheet
used instead of Plain colour

PVC sheet
08110 Add to items 08106 to 08109
if fixed in repairs to existing

doors
08111 All as per item 08106 to 08109
but without the relevant PVC

sheet
08112 Extra for PVC sheet in lipping
in case of PVC sheet is heat
bent as lipping on the edges

of doors

ih oh lh pknj DySfMax lkexzh


S&F
Thickness of sheet in mm

pknj dh eksVkbZ feeh- esa


1mm
Rs.
294.90

1.5mm
Rs.
347.90

2mm
Rs.
454.10

374.50

440.90

520.50

653.30

izfr oXkZ ehVj


08106 likV jax dh ih oh lh pknj]
likV njoktksa ij LFkkiu ;k fcNkuk
jcM vk/kkfjr fpidkus okys nzO;
ds }kjk] fufnZf"Vdj.k ds vuqlkj
dk;ZLFky ij vkiwfrZ o LFkkiu
08107 lc en 08106 tSlk fdUrq likV
jax dh pknj dh ctk; ydMh
ds d.kksa lh fizV dh xbZ ih oh lh
pknj yxk dj
08108 lc en 08106 tSlk fdUrq likV
jax dh pknj dh ctk; ,d rjQh
izhySe ih oh lh pknj yxk dj
08109 lc en 08106 tSlk fdUrq likV
jax dh pknj dh ctk; ,d rjQh
izhySe ih oh lh pknj dks
FkekZQksjfeax }kjk mHkkj dj yxkuk

772.80

49.00

49.00

49.00

109.00

109.00

109.00

58.80

58.80

58.80

08110 tksMs en 08106 ls 08109 lh es]a


;fn LFkkiu eqjEer esa ekStnw k njoktksa
ds lkFk gS
08111 lc en 08106 ls 08109 lh tSlk
fdUrq lac} ih oh lh pknj ds cxSj
08112 vfrfjDr fyfiax esa ih oh lh pknj
ds fy;s ;fn ih oh lh pknj ds
fy;s ;fn ih oh lh pknj dks xeZ
djds eksM dj] njoktksa ds fdukjksa
ij fyfiax fd;k tkuk gSA

151

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
SOLID PVC WALL LINING

Bksl ih oh lh nhokj ykbfuax


ih- oh- lh- xksVsa vkSj ih- oh lh ikh vyx ls ekis tk;saxs

PVC fillets & PVC strips shall be measured


separately
PER SQUARE METRE

izfr oxZ ehVj

S&F
Rs.

08113 Solid PVC Wall Lining consisting of


5mm thick Plain colour PVC sheet
inclusive of solvent cement and fixing at
site on PVC frame as per specifications

and drawing
08114 All as per item No.08113 but wood grain
printed PVC sheet used instead of plain

colour sheet

08113 Bksl ih oh lh nhokj ykbfuax 5 feeh eksVh ih


oh lh pknj dh] lksYoSUV lhesUV lesr]
fufnZf"Vdj.k o Mkbax ds vuqlkj ih oh lh se
ds mij dk;Z LFky ij LFkfir

1145.60

08114 lc en 08113 tSlk fdUrq likV jax pknj dh


ctk; ydMh ds d.kksa lh fizV dh xbZ ih oh lh
pknj yxkuk
08115 lc en 08113 tSlk fdUrq likV jax pknj dh
ctk; ,d rjQ izhySe ih oh lh pknj yxkuk

900.00

08115 All as per item No.08113 but single side


prelam PVC sheet used instead of plain

colour sheet
08116 All as per item No. 08113 to 08115 but

without the relevant PVC Sheet


PVC FILLET
PER RUNNING METRE
08117 5mm thick PVC sheet fillet of width
35mm for wall paneling inclusive of
fixing on to wall to make PVC Frame as

per specification and drawing.


08117A Ditto but without PVC sheet fillets

966.30

08116 lc en 08113 ls 08115 tSlk fdUrq lac) ih oh


lh ds cxSj
iz f r ehVj
08117 5 fe eh eksVh ih oh lh [knj dh xksV] 35 feeh
pkSMh nhokj ij LFkkiu lfgr ih oh lh se dks
fufnZ"Vdj.k vkSj Mkbx ds vuqlkj cukuk

103.40

93.20

08117 A mi;qDZ Rk fdUrq ih oh lh pknj dh xksVksa ds fcuk

73.50

INSULATED PVC WALL LINING


ihPVC strips shall be measured separately
PER SQUARE METRE

08118 lnsulated PVC Wall Lining


consisting of PVC Insulated Panels
having expanded polystyrene (EPS)
stuck to 2mm thick plain colour PVC
sheet duly fitted into the wall as per

specifications and drawing


08119 All as per item no. 08118 but PVC
Insulated Panel with wood grain
printed PVC sheet used instead of

plain colour sheet.


08120 All as per Item no. 08118 but PVC
Insulated Panel with Single Side
Prelam PVC sheet used in-stead of

plain colour sheet


08121 All as per item 08118 to 08120 but
without relevant PVC Insulated

Panels

oh- lh- ikh vyx ls ekis tk;saxs


izfr oxZ ehVj

S&F
Thickness
of insulated
PVC wall
lining
25mm

Thickness
insulated
PVC wall
lining
40mm

Rs.

Rs.

947.60

1000.70

947.60

1000.70

1160.00

1213.10

98.00

86.70

08118 vojks/kh ih oh lh ds nhokj vLRkj


vojks/kh ih oh lh fnYys ls cuk ftles
,DlisaMsM iksfyLVjhu bih,l 2 fe eh
ih oh lh pknj ls lVk gqvk fufnZf"Vdj.k
o Mkabx ds vuqlkj nhokj esa yxkuk
08119 lc en 08118 tSlk fdUrq ih oh lh
vojks/kh fnYys es likV jax pknj dh
ctk, ydM+h ds d.kksa lh fizUV dh xbZ
ih oh lh pknj yxkb tk,
08120 lc en 08118 tSlk fdUrq ih oh lh
vojks/kh fnYys es likV jax pknj dh ctk,
,d rjQh izhySe ih oh lh pknj yxkb tk,

08121 lc en 08118 ls 08120 ch tSlk fdUrq


lca} ih oh lh vojks/kh fnYys ds cxSjA

152

SECTION 8

SECTION 8JOINERY
[k.M 8& c<+bZfxjh
SOLID PVC SANDWICH PANEL FOR PARTITIONS

Bksl ih oh lh lSUMfop fnYyk] vyxkus okyh nhokj ds fy,


M.S. angle frame, PVC channel & strips shall be
measured separately.
PER SQUARE METRE
08122 40mm thick Solid PVC Sandwich Panel
with lmm Plain PVC Sheet on both sides
suitably fixed in M.S. angle frame work

as per specification & drawing


08123 All as per item 08122 but both side 1mm
Printed PVC sheet in lieu of plain PVC

sheet
08124 All as per item 08122 but both side 2mm
Plain PVC sheet in lieu of 1 mm plain

PVC sheets
08125 All as per item 08122 but both side 2mm
Printed PVC sheet in lieu of 1 mm plain

PVC sheet
08126 All as per item 08122 but both side 2mm
single side prelam PVC sheet in lieu of

1 mm plain PVC shcet


08127 All as per item08122 to 08126 but without
relevant solid PVC sandwich panel

,e- ,l yksgs se ih- oh- lh- pSuy vkSj iV~Vh vyx ls ekis tk,xsAa
S&F
Rs.

759.10

1040.50

1199.80

1000.70

1557.90
98.00

izfr oxZ ehVj


08122 40 feeh eksVkbZ ds Bksl ih oh lh lS.Mfop fnYys
ftlds nksuks rjQ nksukas rjQ 1 fe eh likV ih
oh lh pknj gS mfpr :i ls fufnZf"Vdj.k o
Mkbax ds vuqlkj uje yksgs ds se esa LFkkfir
08123 lc en 08122 tSlk fdUrq nksuks rjQ 1
feeh likV ih oh lh pknj dh ctk; 1
feeh fizUV dh gqbZ ih oh lh pknj
08124 lc en 08122 tSlk fdUrq nksuks rjQ 1
feeh likV ih oh lh pknj dh ctk; 2 fe
eh ih oh likV pknj
08125 lc en 08122 tSlk fdUrq nksuks rjQ 1
feeh ih oh lh pknj dh ctk;] 2 feeh fizUV
dh xbZ ih oh lh pknj
08126 lc en 08122 tSlk fdUrq nksuks rjQ 1
feeh likV ih oh lh pknj dh ctk; 2
feeh ,d rjQh izhySe ih oh lh pknj
08127 lc en 08122 ls 08126 tSlk fdUrq lac}
Bksl ih oh lh lS.Mfop fnYys ds cxSjA

FEATHERED EDGES PVC SHEET IN STRIPS & CHANNEL FOR SOLID PVC WALL
LINING, SOLID PVC PARTITIONS
PER SQUARE METRE
08128 5mm thick plain colour PVC sheet in
strips & channel feathered at the edges
for fixing on Solid PVC Wall Lining,
Insulated PVC Wall Lining, and Solid
PVC Partitions inclusive of Solvent

Cement and fixing at site.


08129 All as per item no 08128 but 5mm
Printed PVC sheet used instead of

plain colour PVC shect


08130 All as per item no 08128 but 5mm
Prelam PVC sheet used instead of

plain colour PVC sheet


08131 All as per item 08128 to 08130 but
without the relevant PVC sheet

S&F

izfr oxZ ehVj

Rs.

08128 5 feeh eksVh likV ih oh lh nhokj iVVh o pSuy


es]a fdukjksa ij ia[k tSlh ih oh lh nhokj vLrj
ij] vojks/kh ih oh lh nhokj vLRkj ij o Bksl ih
oh lh vyxkus okyh nhokj ij LFkkiu ds fy,
lkSYoSUV lhesUV o dk;Z LFky ij LFkkiu lesr

978.70

1019.80

1071.50
431.20

08129 lc en 08128 tSlk fdUrq likV jax dh


ih oh lh pknj dh ctk; 5 feeh fizUV dh
xbZ ih oh lh pknj yxkbZ tk,
08130 lc en 08128 tSlk fdUrq likV jax dh ih
oh lh pknj dh ctk; izhySe 5 fe eh ih oh
lh pknj yxkbZ tk,
08131 lc en 08128 ls 08130 ch tSlk fdUrq
lECkfU/kr ih oh lh ds cxSjA

153

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
SOLID PVC INSULATION PANEL FOR FALSE CEILING
Aluminium/GI/M.S. Grid shall be measured separately.
PER SQUARE METRE

08132 PVC insulation panels with EPS


stuck to 1mm plain PVC sheet
suitably placed in false ceiling grid
made of Aluminium/G.I./M.S. as
per specification and drawing
08133 All as per item no 08132 but 1mm
printed PVC sheet used in lieu of

plain PVC sheet


08134 All as per item no 08132 and 08133
but without relevant PVC insulation

panel.

S&F
ThickThick ness
ness of
of PVC
PVC
insulation
insulation panel
panel
40mm
10mm
Rs.

Rs.

737.70

915.20

776.50

971.60

112.70

112.70

PVC PARTITION
PER SQUARE METRE

S&F

Fixing only

08135 52mm thick PVC Partition consisting


of 12mm thick plain solid PVC ply
sheet reinforced with frame work
made from 40mm x 20mm MS tubes.
In between two MS tubes, 5mm thick
Plain heat moulded 'C channel of
size 75mmx50mm with feathered
edges shall be fixed on the floor, wall
and ceiling. Plastic ply opanel shall
be inserted in the PVC 'C channel.
The first & last MS tube should be
errected such that it is inside a PVC
'C channel, in between adjoining
plastic panel, 5mm thick x75mm
width plain PVC sheet feathered at
edges shall be stick on the front &
back face using solvent cement

complete.

Rs.

Rs.

1220.00

42.00

izfr oxZ ehVj

08132 ih oh lh vojks/kh fnYys 1 feeh likV ih oh


lh pknj bih,l LVd fpidk gqvk] cukoVh
Nr dh tkyh ,Y;qehfu;e@tLrk p<k
yksgk@uje gksgk dh cuh fufnZf"Vdj.k o
Mkbax ds vuqlkj mfpr #i ls yxk;k x;k
08133 lc en 08132 tSlk fdUrq likV ih oh
lh pknj dh ctk; 1 fe eh fizUV dh gqbZ
ih oh lh pknj yxkbZ tk,
08134 lc en 08132 o 08133 tSlk fdUrq lac}
ih oh lh vojks/kh fnYyh ds cxSjA

154

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
PER SQUARE METRE
08136 All as per Item No 08135 above but
12mm thick both side printed solid
PVC plastic ply sheet and 5mm thick

printed heat moulded 'C channel


08137 All as per Item No 08135 above but
12mm thick both side prelam PVC
plastic ply sheet and 5mm thick
prelam heat moulded 'C channel

S&F

Fixing only

Rs.

Rs.

1367.00

42.00

1474.00

42.00

SOLID PVC FRAME


RUNNING METRE

S&F
Rs.

08138 Solid PVC frame (Single Rebated) of


size 60mm x 30mm made out of solid
PVC foam with homogenous fine
cellular structure having smooth
outer integral skin with suitable metal
stiffner and fixed with 100 x 8 sheet
metal CSK screws complete all as
specified and as shown on drawing
(Note :- Door frame shall be water
proof, termite proof, elegant and
should have excellent screws holding
strength to fix hinges and hold doors

properly for a long life)

529.90

SQUARE METRE

S&F

08139 Factory made soild PVC profiled


panel door shutter 28mm thick with
integral skin as frame & 3mm thick
high pressure compact laminate on
both side of approved colour as infill,
with 'C type Gl or 40 x 20 x19 of MS
pipe as stiffner & supplying & fixing
in frame at site as per specifications

& drawing.

Rs.

08140 Supply and fix 30mm thick single


piece,
coloured
ABC
(ACRYLONITRILE BRUTADINE
STYRENE) coated, PUF filled door
shutters with PUF (Poly Urethane

2055.70

155

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
SQUARE METRE

S&F

Foam) insulation of minimum density


40 Kg/Cum filled in between two ABS
sheets of thickness 1.2mm (min), border
covered with insitu pasted ABS strips
of width equal to thickness of door
shutters, 1.2mm thickness, reinforced
with two number 10mm CTD bars, preembedded with wooden blocks of
suitable sizes for receiving hinges,
tower / sliding bolts, towel rails,
handles etc, with/without embossed

pattern.

Rs.

1811.80

08141 Supply and fix 30mm thick single piece,


coloured ABC (ACRYLONITRILE
BRUTADINE STYRENE) coated, PUF
filled door shutters with PUF (Poly
Urethane Foam) insulation of minimum
density 40 Kg/Cum filled in between
two ABS sheets of thickness 1.2mm
(min), border covered with insitu
pasted ABS strips of width equal to
thickness of door shutters, 1.2mm
thickness, reinforced with two number
10mm CTD bars, pre-embedded with
wooden blocks of suitable sizes for
receiving hinges, tower / sliding bolts,
towel rails, handles etc, with/without

embossed pattern.

1817.80

156

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
PRODUCT DRAWINGS
DIAGRAM SHOWING DIFFERENT SECTIONS OF FACTORY MADE SOLID PANEL PVC DOOR SHUTTERS
(ITEM - 08080)
Top View
Gap Insert Top
15mm Square Tube
Top Rail

Top Rail

Beading for Top Rail


C-Channel
Panel
Beading for C-Channel
Lock Rail (Upper)
Lock Rail

Hings 3 nos.
Lock Rail (Lower)
19mm Square Tube

Beading for Bottom Rail


Bottom Rail
Bottom Rail
15mm Square Tube
Gap Insert Bottom

Diagrammatic Representation of 6.5x2.5 Door


(Scale - 1 : 25)

Hinge

PVC
Strips

Gap
Insert
below C
Channel

Gap Insert for top

Side View

Lock Rail
(Upper)

15mm M.S. Square Tube


Panel

Panel
Gap Insert below Top Rail
Top Rail
Beading for Top Rail

19mm M.S.
Square Tube

C Channel

Beading for
C Channel

Sectional View (aa) Stile


Sectional View (dd) is mirror image of (aa)

Lock Rail
(Lower)

Panel

Sectional View (cc) Lock


Sectional View (bb) Top Rail
Rail
Sectional View (ee) is mirror image
of (bb)

(Scale -1 : 3)
(Note: All Dimenstions are in mm)

157

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
FACTORY MADE PRINTED SOLID PANEL PVC DOOR SHUTTERS (ITEM - 08081)

Decorative PVC Beading


Gap Insert
19mm M.S. PVC below C Dccorative
Square Tube Strips Reading
PVC Beading

5mm Printed
5mm
5mm Printed
PVCC Channel PVC
PVC Panel
Beading

Sectional View (Stile)


(Scale - 1 : 3)

Gap Insert for Top


Lock Rail (Upper)
15mm M.S. Square Tube
Top Rail

5mm Printed PVC Panel

Gap insert below Top


Rail
PVC Beading

Lock Rail (Lower)

Decorative PVC Beading


5mm Printed Panel

Sectional View (Rail)


(Scale - 1 : 3)

Decorative PVC
Beading

Sectional View (Lock Rail)


(Scale - 1 : 3)

FACTORY MADE SINGLE SIDE PANEL PVC DOOR SHUTTERS (ITEM - 08082)
19mm M.S.
PVC Square
5mm PVC 5mm PVC
Strips Tube
C Channel Panel

Gap insert for Top


15mm M.S. Square Tube
Top Rail
Gap insert below
Top Rail
PVC Beading

Hings Gap insert PVC


below C Beading
Channel

Lock Rail
(Upper)
Panel
Lock Rail
(Lower)

5mm PVC Panel

FACTORY MADE BOTH SIDE PRELAM SOLID PANEL PVC DOOR SHUTTERS (ITEM - 08083)

19mm
M.S.
Square
Hings Tube

Gap
Insert
below C
Channel

7mm
Beadingt
for C
Channel

Gap Insert for Top

Taper Lock Rail


(Upper)

15mm M.S. Square


Tube

Panel

Gap Insert below Top Rail


Top Rail
5mm PVC
Strips

5mm
Taper C
Channel

Sectional View Stile


(Scale - 1 : 3)

Lock Rail (Lower)

Beading for Top Rail


5mm Panel
Panel

Sectional View Top Rail


(Scale - 1 : 3)

Sectional View Lock Rail


(Scale - 1 : 3)

158

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
FACTORY MADE FULLY GLAZED SOLID PANEL PVC DOOR SHUTTERS (ITEM - 08084 to 08086)

19mm
M.S.
Square PVC
Tabe
Strips

Gap Insert for Top

Gap Insert
below C Decorative
PVC Beading
Channel

5mm PVC
C Channel

5mm
PVC
Beading

15mm M.S. Square Tube


5mm PVC Panel

Top Rail
Gap insert below Top
Rail
PVC Beading

5mm thick
Glass

Sectional View (Stile)


(Scale - 1 : 3)

5mm thick Glass


Decorative PVC
Beading
Lock Rail (Upper)

Lock Rail (Lower)

Decorative PVC Beading

Decorative PVC
Beading

5mm Thick Glass

5mm thick Glass

Sectional View (Rail)


(Scale - 1 : 3)

Sectional View (Lock Rail)


(Scale - 1 : 3)

FACTORY MADE PARTLY GLAZED SOLID PANEL PVC DOOR SHUTTERS (ITEMS-08087 to 08090 C)
Gap Insert Top
15mm Square Tube
Top Rail
Beading for Top Rail
C - Channel
5mm Glass Pane
Beading for C - Channel

19mm
M.S.
Square PVC
Tube Strips

Gap Insert
below C
Channel

Decorative
PVC
Beading

Lock Rail (Upper)


Hinge 3 nos.
Lock Rail (Lower)
19mm Square Tube
5mm PVC Sheet Panel
Beading for Bottom Rail
Bottom Rail

5mm PVC
C Channel

5mm PVC
Beading

Sectional View (Stile)


(Scale - 1 : 3)

15mm Square Tube


Gap Insert Bottom

Diagrammatic Representation of 6.5x 2.5 Door


(Scale - 1 : 25)
5mm thick Glass
Decorative PVC Beading
Gap insert for Top
Lock Rail (Upper)
15mm M.S. Square Tube
Top Rail
Gap insert below Top Rail

5mm PVC Panel


Lock Rail (Lower)

PVC Beading
Decorative PVC Beading

Decorative PVC Beading

5mm thick glass

5mm PVC Panel

Sectional View (Rail)


(Scale - 1 : 3)

5mm thick
Glass

Sectional View (Lock Rail)


(Scale - 1 : 3)

159

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
FACTORY MADE WIRE GAUZED SOLID PANEL PVC DOOR SHUTTERS (ITEM - 08091 to 08093)
Gap Insert Top
15mm Square Tube
Top Rail

PVC Solid
Hinge Strips M.S. Rod

G.I. Wire
Gauze

Beading for Top Rail


C Channel
G.I. Wiremesh
Beading for C Channel
Lock Rail (Upper)

5mm PVC
Beading

19mm M.S. 5mm PVC


C Channel
Square
Tube

Sectional View as (Stile)


(Scale - 1 : 3)

Hinge
Lock Rail (Lower)
19mm Square Tube
G.I. Wiremesh
Beading for Bottom Rail
Beading Rail
15mm Square Tube
Gap insert Bottom

Diagrammatic Representation of 6.5 x 2.5 door


(Scale - 1 : 25)

Sectional View bb
(Rail)
(Scale - 1 : 3)

Sectional View cc
(Lock Rail)
(Scale - 1 : 3)

FACTORY MADE FULLY LOUVERED SOLID PANEL PVC DOOR SHUTTERS (ITEM - 08094)
Gap Insert Top
15mm Square Tube
Top Rail

PVC
Hinge Strips

Gap insert
below C
Channel

5mm PVC
Louver strip

Beading for Top Rail


C Channel
Louvers

19mm M.S. 5mm PVC


Square Tube C Channel

5mm PVC
C Channel

Sectional View aa (Stile)


(Scale - 1 : 3)
Hinge
Lock Rail (Lower)
19mm Square Tube

Gap insert for top


15mm MS square tube

Louvers
Gap insert below top rail
Beading for Top Rail
Bottom Rail
15mm Square Tube
Gap insert Bottom

Diagrammatic Representation of 6.5 x 2.5 door


(Scale - 1 : 25)

Top rail
PVC Beading

Sectional View bb (Rail)


(Scale - 1 : 3)

160

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
FACTORY MADE SOLID PVC DOOR FRAMES (ITEMS - 08095 to 08097)
150mm Long L shape
Bracket 15mm x15mm sq.
Tube 19 Guage inserted
into 19x19mm M.S. Square
Tube of 19 Guage

75mm Long
M.S. Screws

Gap Insert for Top


Hinge

19mm M.S. Square


Tube of 19 Gauge
Gap Insert below Top Rail
Top Rail

75mm Long M.S. Screws


fixed with PVC Fasteners
for Fixing Frame to Wall

Beading for Top Rail


PVC Panel

DETAIL AT (C)
(Scale - 1 : 3)

ELEVATION

FACTORY MADE PARTLY GLAZED SOLID PANEL PVC DOOR SHUTTERS (ITEMS-08087 to 08090)
Rubber Gasket
75x30x5mm PVC C
Channel

5mm PVC Beading


5mm PVC Panel

75mm Long
Aldrop Bolt
M.S. Screw with
19mm Square Tube
PVC Fastner
of 19 Gauge

SECTIONAL VIEW
(Scale - 1 : 3)

19mm M.S. Square


Tube of 19 Gauge

Hinge

19mm M.S. Square


Tube of 19 Gauge

SECTIONAL VIEW
(Scale - 1 : 3)

FACTORY MADE SOLID PVC DOOR DOUBLE FRAMES (ITEMS - 08098 to 08100)

SECTIONAL VIEW
(Scale - 1 : 3)

161

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
FACTORY MADE SOLID PVC MOULDED DOOR SHUTTER (ITEM - 08101 to 08105)

2mm
Moulded
PVC Sheet

Mortise
Lock

Mortise
Lock

Hinge

Hinge

2mm
Moulded
PVC Sheet

2mm
Moulded
PVC Sheet

2mm
Moulded
PVC Sheet

Mortise
Lock

Mortise
Lock

Hinge

Hinge

Diagrammatic Representation of 6.5 x 2.5 Door

FACTORY MADE PARTICLE BOARD CORE SOLID PVC MOULDED DOOR SHUTTER

Steel
Screw

2mm Moulded
PVC Sheet

5mm PVC
Sheet Lipping

12mm x 2Nos.
Particle Board

Wooden
Putti

2mm PVC
Sheet

2mm PVC
Sheet

2mm Moulded
PVC Sheet

12mm x 2Nos.
Particle Board

Steel
Screw

5mm PVC
Sheet Lipping

Sectional View (bb)


(Scale - 1:3)

Sectional View (aa)


(Scale - 1:3)

FACTORY MADE EPS CORE SOLID PVC MOULDED DOOR SHUTTER


2mm PVC
Sheet Lipping

5mm PVC
Sheet Lipping

2mm PVC
Sheet Lipping

2mm Moulded
PVC Sheet

19mm M.S.
Tube

Sectional View (aa)


(Scale - 1:3)

36mm EPS

36mm EPS

19mm M.S.
Tube

2mm Moulded
PVC Sheet

2mm PVC 5mm PVC


Sheet Lipping
Sheet

Sectional View (bb)


(Scale - 1:3)

162

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
SOLID PVC WALL LINING (ITEM - 08113 to 08115)

1 wide
5mm PVC
Fillet Frame

Adjacent
Wall

Screw fixed
inside the
wall

Without Panelling Sheet

Without Panelling Sheet


Screw

5mm PVC
Sheet

5mm PVC
Fillet

Solvent
Adhesive

5mm PVC
Sheet

Sectional View (bb)


(Scale - 1:3)

Screws fixed in wall


5mm PVC
Fillet

Sectional View (aa)

View (cc)
Steel
Screw

SOLID PVC INSULATED WALL LINING (ITEM - 890 to 890B)

EPS

Steel
Screw
PVC Strips
Insulated PVC Panel
Insulated PVC Panel

Sectional View (AA)

EPS

EPS

Steel
Screw

EPS

Solid PVC Insulated Wall Lining


Sectional View (bb)

163

SECTION 8

SECTION 8JOINERY
[k.M 8& c<bZfxjh
SOLID PVC PARTITIONS (ITEM - 08122 to 08126)

5mm PVC Fillet

PVC Sandwich Panel

Insulated PVC Panel

40mm thick EPS


Sandwich Panel

40mm thick EPS


35mmx35mmx5mm Sandwich Panel
M.S. Angle

40mm thick EPS


Sandwich Panel

35mmx35mmx5mm
M.S. Angle

100m x 50mm
Toper C Channel
Steel Screw

Steel
Screw

75mm Toper Ship

75mmx50mm
Toper C Channel

Sectional View (AA)

Sectional View (BB)

Sectional View (CC)

SOLID PVC INSULATION PANEL FOR FALSE CEILING (ITEMS -08132 to 08134)
1mm PVC Sheet

1mm PVC Sheet

EPS Sheet

EPS Sheet

10mm Insulation Panel for


False Ceiling

40mm Insulation Panel for


False Ceiling

For Further Drawings, please refer page No. XIII to XV

164

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds ekhuh miknku
SPECIAL CONDITIONS
foksk krsZa
9.1 MeasurementsThe sizes by which the various 9-1 eki
& og ifjek.k ftlds }kjk ekhuh miknkuksa dh fofHkUu oLrqvksa
eki&
articles of builders hardware are designated are given in
dks euksuhr fd;k x;k gS] mls uhps dh rkfydk esa fn;k x;k gSA
the table below. In respect of articles which are specified
,slh oLrq,a ftUgsa lacfU/kr Hkkjrh; ekud fofufnZVksa ds lerqY;
to conform to relevant Indian Standard Specifications, the
fufnZVr gSa mudk ifjek.k lacfU/kr ekud ds dFkukuqlkj gSA
sizes are as described in the relevant Standard.
SI.No. Name of article

How measured

1.

Length of barrel

3.
4.

Bolt tower and


barrel, of nonferrous metal
Bolt tower, semibarrel of nonferrous metal
Bolt tower of ferrous metal
Locking bolt
Bolt sliding

5.

Bolt skeleton tower

6.
7.
8.

Bolt flush
Butt hinges
Parliament hinges

9.

Tee hinges

10.

Spring hinge double acting

11.
12.

Spring rat tail


Spring patent helical
Handles
Cupboard locks

1A
2.

13.
14.
15.
16.
17.
18.
19.
20.

20A
21.

Rim latches
Mortice lock
Mortice night
latches
Drawer locks
Mortice latch
(vertical type)
Fanlight pivot

Fanlight catch
Fastners, cockspur

Length of bolt

Length of bolt

Length of face plate


Length of joint or knuckle
Width between flanges and
height of parliament hinges
Length of the leaf from joint
to points
Length of spring cylinder for
regulating spring of butt
hinges
The distance from the
centre of the spindle to the
centre of the roller
Grip length
Vertical length of face
across the body excluding
the striking plate
Overall length of the
body measured from outside face of the
frame to the rear end
The flat overall size in
elevation of the plate with
spring catch excluding the
striking plate
Dia of the bolt
The length of handle from
the centre of pivot or hinged
joint

-la - oLrq dk uke


1- dkoyk pV[kuh o
xksy vykSg /kkrq dh
pVduh
1d dkoyk&pVduh
v/kZukyh vykSg
2- dkoyk pVduh
ykSg/kkrq dh
3- ikku&dkoyk
4- dkoyk&vxZyk
5- dkoyk&<kapk
pVduh
6- dkoyk&likV
7- VDdjh&dCts
8- eqMoka dCtk
9- Vh dCts
10- nks rjQh fdz;k dekuh dCts

111213141516171819-

dekuh likV
dekuh daMqyh
gRFks
dioksMZ rkys

jhe pVduh
[kkapk rkys
[kkapk lqj{kk pVduh
njkt rkys
[kkapk pVduh [kM+h
fdLe
20}kj jkskunku dhyd
vxz
20d jkskunku idM+
21c/kad dkSd lij

dSls eki gksxkh


uky xksys dh yEckbZ
dkoys dh yEckbZ

dkoys dh yEckbZ

vxzIysV dh yEckbZ
tksM+ ;k ikjpk dh yEckbZ
dksjksa ds chp dh pkSM+kbZ
tksM+ ls fcUnq rd iYys dh
yEckbZ
VDdjh dCts dh dekuh dks
pykus okys dekuh osyu dh
yEckbZ
rdyh ds dsUnz ls jksyj ds
dsUnz rd dk Qklyk
idM+ yEckbZ
tqM+ok IysV dks NksM+dj dk;k
[kM+h yEckbZ
laiw.kZ fiaM yEckbZ se ds
ckgjh eksgjs ls fiNys Nksj rd

tksM+ IysV NksM+dj IysV o


dekuh dSap dh likV yEckbZ
CkksYV dk O;kl
uki dekuh ;k tksM+ IysV ls ewB
dh yEckbZ

165

SECTION 9

SECTIONBUILDERS HARDWARE
[k.M 9 & fuekZrk ds ekhuh miknku
SPECIAL CONDITIONS-Contd...
foksk krsZ tkjh...
-la 22-

oLrq dk uke
c/kad o Vsd Qjek

dSls eki gksxh


izB IysV lfgr laiw.kZ yEckbZ

23-

dhyd o lkfdV
jkskunku dhyd

izR;sd IysV dk ifjeki

24252627-

njkt iqy
njkt gSaMy
Vksih [kwaVh
Vksih o dksV gqd

28-

vyekjh gqd

Straight length excluding


screwed end

29-

isp gqd] izlk/ku ;k


di uewuk

uksdnkj fdukjk NksM+dj lh/kh


yEckbZ

Straight length between the


centre of eyes when fixed

30-

dsfou ;k Qjek gqd


IysV Nsnh

LFkkiu ds ckn Nsn ds dsUnz ls


lh/kh yEckbZ

Overall length of the hook


excluding the screwed eye
Maximum diameter of the
knob
Overall length of hasp
including the hinged plate
Length measured from the
centre of the hinge to the end
of hasp excluding the hinged
plate

31-

rkj gqd uqdhys Nsn


ds lkFk
?kqafM;ka

Nsn dks NksM+dkj gqd dh iwjh


yEckbZ
?kqaMh dk vf/kd O;kl

Overall length of the


screwed eye & diameter of
wire shall be stated
The weight and width of the
door to which it is intended
to be fitted

34-

pwMhnkj us=d

35-

}kj ca/kd gkbMkfs yd

ftl njokts esa yxkuk gS mldk


otu o pkSMkbZ

36-

lrr fi;kuksa dCts

iYyksa tc [kqys gks fd iwjh


pkSMkbZ

SI.No. Name of article

How measured

22.

Extreme length including


thickness of back plate
The flat overall size in
elevation of the plate with
spring catch excluding the
striking plate

23.

Fastners and stays


(casement)
Pivots and sockets
(Fanlight pivots)

24.
25.

Drawer pulls
Drawer handles

26.
27.

Hat pegs
Hat and coat
hooks
Ward robe
hooks
Screw hooks,
dresser or cup
pattern

28.
29.

30.

31.
32.
33.

Cabin or casement
hooks with eyes
on plate
Wire hooks with
screwed eyes
Knobs
Hasp and staple:
(a) Wire type
(b) Plate type
(safety type)

Grip length
Extreme length including
thickness of plate measured
diagonally from extreme top
of fixing plate to the extreme
top of knob

34.

Screwed eyes

35.

Door closer (Hydraulically


regulated)

36.

Continuous (piano) Overall width of flaps


hinges
(when open)

9.2 Rates
(a) The rates for Fixing only include the supply of
screws (or bolts, nuts and washers where
specified) including boring for bolts, also necessary labours in sinkings, key holes, mortices
etc. to soft wood or hard wood.
(b) Where the rates for Fixing only are common to
steel, iron, brass and aluminium article the rates
shall be deemed to include for fixing brass articles

3233-

Nids o dqaMs
d rkj fdLe
[k IysV fdLe
jf{kr izdkj dk

idM yEckbZ
fLFkj IysV khkZ ls ukSo ds khkZ
rd iwjh yEckbZ ekih tk;sxh

dCtk IysV lfgr Nids dh iwjh


yEckbZ
dCtk IysV NksM+dj dCts ds
dsUnz ls Nids ds var rd
ekik tk;sxk
iwjh yEckbZ] pwMhnkj us=d

9-2 njs a
d *dsoy LFkkiu* dh njksa esa dCtksa ds fy;s Nsn djus lfgr
ispksa ;k tgka fufnZ"V gks dCts] dkoys o oklZy dh vkiwfrZ
djuk fu{ksi pkoh Nsnks]a Hkhrjh Nsnksa ds Je vkfn Hkh 'kkfey
gSA
[k tgka *dsoy LFkkiu* dh njsa] bLikr] yksgk] ihry rFkk
vY;qfefu;e oLrqvksa ds fy;s leku gSa rks le>k tk;sxk
fd bu njksa esa ihry dh oLrqvksa dks ihry ds ispksa ls o

166

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds ekhuh miknku
SPECIAL CONDITIONS-Contd...
foksk krasZ tkjh...
with brass screws and steel/iron and aluminium
articles with mild steel wood screws or as
indicated.
(c) The rates for Supplied and Fixed include the
supply of screws (or bolts, nuts and washers
where specified) to match the article.

(d) In case the builders hardware is ordered to have


chromium or nickle plated finish, the rates for
supplied and fixed shall be enhanced 60
percent for mild steel fittings and 20 percent for
brass fittings except where an article is described
in the item to have chromium/nickle plated finish.

?k

(e) The rates in this section are for machine-made


and factory fabricated articles. Hinges, bolts, etc.,
where ordered to be forged by hand shall be paid
for under Section 10Steel and Iron work.

(f) The rates for add if fixed in repairs include for


taking off the old articles and removing to store;
also for plugging up old key holes, spindle holes,
screw holes, etc., where necessary, and painting
one coat on new wood to match existing. The
rates for taking off and refixing also include for
adjustment, plugging up key holes, etc. as
required.
(g) If brackets or other fittings are secured to plugs
instead of to ordinary woodwork, the plugs shall
be measured extra; cementing hinges, hooks etc.,
into stone or concrete mortices shall be measured
separately under the appropriate items unless
otherwise described.
(h) The rates include for easing and leaving in good
working condition.

>

bLikr@yksgs o vY;qfefu;e dh oLrqvksa dks uje bLikr


ds ydM+h esa yxus okys ispksa ls dlk x;k gS ;k tSlk
lwfpr gksA
*vkiwfkZ o LFkkfir* dh njksa esa oLrq ds feyku ds ispksa ;k
dkoysa] f<ofj;ka o oklZy] tgka fufnZ"V gks dh vkiwfkZ
djuk Hkh 'kkfey gSA
;fn ksfe;e ;k fudy eqyEek;qDr ifj"d`r fuekZrk ds
e'khuh miknkuksa dk vkns'k gS rks *vkiwfkZ o LFkkfir* dh njsa
uje bLikr miLdj ds fy;s 60 izfr'kr rFkk ihry ds
miLdjksa ds fy;s 20 izfr'kr c<+kbZ tk;saxh flok; ml
oLrq dks NksM+dj ftldk ksfe;e@fudy eqyEek;qDr
gksus dk en esa mYys[k gksA
bl [kaM dh njsa e'khu ls cuh ,oa dkj[kkus esa fojfpr
oLrqvksa ds fy;s gSAa tgak gkFk ls cus dCts dkoys vkfn dk
vkns'k fn;k x;k gS rks og [kaM 10& bLikr o yksgk dk;Z
ds vUrxZr ns; gksaxsA
*tksMsa+ ;fn ejEer esa* dh njksa eas] iqjkuh oLrqvksa dks
fudkyus o Hk.Mkj esa igqapkus ds lkFk] iqjkus pkoh fNnzksa]
rdyh fNnzk]as isp fNnzkas vkfn cUn djuk] rFkk tgka t:jh
gks] fo|eku ls feyku ds jksxu dh ,d ijr djuk Hkh
'kkfey gSA fudkyus ,oa nqckjk yxkus dh njksa esa
vko';drkuqlkj O;ofLFkr djuk pkoh Nsnksa vkfn dks cUn
djuk Hkh] 'kkfey gSA
;fn czSfdV ;k vU; miLdjksa dks lkekU; ydM+h dk;Z ds
LFkku ij MkVksa ls yxk;k gS rks MkVksa dks vfrfjDr ekik
tk;sxkA dCtks]a gqdksa vkfn dks iRFkj ;k dahV ds Nsnksa esa
lhesaV ls fcBkus ds dk;Z dks tc rd vU;Fkk mYys[k u
gks] mi;qDr en ds vUrxZr izFkd ekik tk;sxkA
bu njksa esa dk;Z dks LkkekU; o lf; n'kk esa laifw jr djuk
'kkfey gSA

BOLTS
pVdfu;ka

If sockets (thimbles) for letting into stone cills, etc., are used in
lieu of staples on plates or plain plates, the same shall be paid
under item 0925 but deduction shall be made under item 0926.

;fn lkdsVksa NYyk dks IysV ij yxs dqUMs ;k lknk IysV ds LFkku
ij iRFkj dh flyksa esa Mkyk tkrk gS] rks mldk Hkqxrku en 0925
ds varxZr gksxk fdUrq dVkSrh en 0926 ds vUrxZr gksxhA

167

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds ekhuh miknku
BOLTS-Contd...
pVdfu;ka& tkjh...
Barrel, semi-barrel and
skeleton tower bolts and
flush bolts
EACH
09001 Mild steel barrel tower
bolts, stove enamelled
black, with bright bolt

and fixed
09002 Brass barrel tower
bolts, with cast or sheet
barrel and rolled or
cast bolts and fixed
09003 Ditto, but with barrel of
extruded section
09004 Aluminium anodised,
barrel tower bolts of ex
truded section and fixed
09005 Mild steel, semi-barrel
tower bolt, open cover,
with sheet pressed barrel,
stove enamelledblackwith
bright bolt and fixed
09006 Mild steel semi barrel
tower bolt, riveted or
spot welded type with
back plates, with bright
bolt and open staple,

and fixed

Length of bolt in mm

pVduh dh yEckbZ feeh esa


75
Rs.

24.20

27.00

39.00

56.00

67.30

42.10

56.80

70.40

22.90

27.70

34.00

15.60

18.30

14.60

16.80

150
Rs.

200
Rs.

300
Rs.

iz R ;s d

09001 pVdfu;ka] uje bLikr dh xksy


dBksj dkyh /kkrq p<+h pednkj

dkoys okyh rFkk LFkkfir


32.90 37.60
42.20
09002 pVdfu;ka eqYkEek;qDr] ;k
<ys dkoys] lfgr] <yh gqbZ
;k pknjh uky dh ihry dh
78.70 108.10 132.60
xksy] rFkk LFkkfir
09003 mi;qDZ r] fdUrq xksy fu"dklu
87.10 113.90 137.40
dkV
09004 fu"dklu dkV dh vY;qfefu;e
,uksMhd`r xksy] rFkk LFkkfir
37.60

52.80

54.00

21.80

27.10

32.40

37.90

18.30

20.40

24.80

27.40

80.10

09008 Aluminium flush bolt,


type 2, anodised and

fixed flush

09010 Add to any of the fore


going items if fixed in

repairs

125
Rs.

18.70

09007 Brass flush bolt, type 2

and fixed flush

09009 Fixing only of any of


the foregoing items

100
Rs.

xksykdj] v/kZ xksykdkj o


<kapk pVdfu;ka rFkk likV
pVdfu;ka

50.50

56.00

11.50

13.60

15.80

16.60

17.10

17.90

3.70

3.70

3.70

4.23

4.23

4.23

09005 uje bLikr dh v/kZ xksy


pVdfu;ka] pednkj dkoys] LVkso
eqyEek;qDr dkyh] lEihfM+r
pknj uky ds lkFk [kqys
vkoj.k okyh] rFkk LFkkfir
09006 uje yksgs dh v/kZ xksykdkj]
pednkj dkoys o [kqys dqUMs
ds lkFk] i[knkj ;k fcUnq ij
>yh gqbZ fdLe dh iz"B IysV
yxh] rFkk LFkkfir
09007 izrhd 2 dh ihry dh likV
pVduh rFkk likV LFkkfir
09008 izrhd 2 dk /kkrq eqyEek;qDr]
vY;qfefu;e dh likV pVduh
rFkk mls likV yxkuk
09009 ij dh enksa dh fdlh oLrq
dk dsoy LFkkiu
09010 tksM+as ij dh enksa es]a ejEer
esa yxh oLrq ds fy;s

168

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds ekhuh miknku
BOLTS-Contd...
pVdfu;ka tkjh...
EACH

Length of bolt in mm

pVduh dh yEckbZ feeh esa

09011 Mild steel skeleton tower bolts with


375
steel sheet pressed plate and
Rs.
staple stove enamelled black, and
mild steel bright bolt and fixed
50.30
09012 Brass skeleton tower bolts with
cast brass plate and staples and rolled
or drawn brass bolt and fixed 398.80

450
Rs.
55.20

600
Rs.
70.10

542.40

839.10

09013 Ditto of extruded section and rolled


or drawn brass bolt and fixed

436.40

601.50

915.80

09014 Aluminium anodised, skeleton


tower bolts with plate, staples and
111.00
bolt of extruded section and fixed
17.00

09015 Fixing only, items 09011 to 09014

123.90
17.00

149.20
17.00

3.70

3.70

09016 Add to items 09011 to 09015 if

fixed in repairs

3.70

iz R ;s d
09011 uje yksgs dh <kapk pVduh] bLikr dh laihfMr
pknj dh o dkyh /kkrq p<+h dkyh ,oa uje
yksgs ds pednkj dkoys lfgr LFkkfir
09012 ihry dh <yh IysV o dqUMs okyh ihry
<kapk pVdfu;ka o csyuuqek ;k vxZyh ihry
ds dkoys rFkk LFkkfir
09013 mi;ZqDr] fu"dklu dkV okys rFkk csyuuqek
;k vxZyh ihry ds dkoys rFkk mUgsa yxkuk
09014 vY;qfefu;e ,UkksM;qDr <kapk pVdfu;ka o
fu"dklu dkV ds dkoys] IysV dqaMs ds lkFk
rFkk LFkkfir
09015 dsoy LFkkiu] ensa 09011 ls 09014
09016 tksMsa+ en 09011 ls 09015 esa ;fn LFkkiuk
ejEer esa dh gS

SLIDING DOOR BOLT WITH HASP AND STAPLE, SUITABLE FOR USE WITH PADLOCK
xn~nh rkys ds lkFk iz;ksx ds fy, mi;qDr Nids dqaMs lfgr] ljdoka }kj fpVdfu;ka
09017 LVkso ,sues y;qDr dkyh] IysVuqek] uje
yksgs dh ljdoka }kj fpVdfu;ka] ftlesa
de ls de 6 pednkj dkoys ftudk
O;kl 12 feeh ls de u gks] pkj dokys
o f<ofj;ka fpVduh dh IysV ij nks
dqaMs dh IysV ij rFkk LFkkfir
09018 ihry dh ljdoka }kj pVduh] Ckkyw
;k <Iik <ykbZ ds ihry ds Nids daqMs
dkoysuqek lfgr rFkk yxkus ds fy;s
csyuuqek ;k vxZyh] ihry ds dkoys
rFkk LFkkfir
09019 Nids daMq s dkoysueq k ds lkFk vY;qfefu;e
feJ/kkrq ,uksM;qDr ljdoka }kj fpVdfu;ka]
o yxkus ds fy;s] <yh gqbZ ;k fu"dklu
dkVksa ;k vY;qfefu;e feJ/kkrq dh fDyi
rFkk LFkkiu dkoys o fu"dklu dkV
;k ,Y;wehfu;e feJ /kkrq <yh ljdoka
fpVdfu;ka o LFkkfir
09020 Fixing only, items 09017 to
36.70 36.70 36.70 36.70 43.10 09020 dsoy LFkkiu] ensa 09017 ls 09019
09019
09021 tksM+sa] en 09017 ls 09020 esa] ;fn
09021 Add to items 09017 to 09020, if
4.20 4.20 4.20 4.20
5.50

fixed in repairs
ejEer esa LFkkfir
Length of bolt in mm
09017 Mild steel sliding door bolts,
pVduh dh yEckbZ feeh esa
plate type, stove enamelled
black, with bright bolt not less 150 200
250
300
375
than 12mm dia with and
Rs. Rs.
Rs.
Rs.
Rs.
including a minimum of 6 bolts
and nuts, four on bolt plate and
two on staple plate and fixed 89.60 101.30 113.10 177.70 198.80
09018 Brass, sliding door bolt with
sand or die-cast brass hasp,
staple (bolt type) and fixing bolt
with rolled or drawn brass bolts
365.70 389.20 412.70 483.20 524.90
and fixed
09019 Aluminium alloy, anodised,
sliding door bolt with hasp,
staple (bolt type) and fixing
clips of sheet, cast or extruded
sections and fixing bolts and
sliding bolts of extruded
sections or cast-aluminium
113.10 124.80 142.50 166.00 190.00
alloy and fixed

169

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9 fuekZrk ds ekhuh miknku
BOLTS-Contd...
pVdfu;ka& tkjh
LOCKING BOLTS
EACH

09022

09023

S&F

vk- o
LFkk-

tksM+s ;fn
ejEer esa
LFkkfir

Steel locking bolts with mild


steel electrogalvanised plate
and bright bolt not less than
Rs.
10mm dia 100mm size
62.50
Aluminium locking bolts,
anodised, with bolt not less
66.00
than 10mm dia, 100 mm size

Rs.
21.40

16.70

97.50

21.40

16.70

09024A Aluminium locking bolt 250


103.60
mm size

21.40

16.70

Steel locking Bolts 250 mm size

ACCESSORIES
EACH

iz R ;s d
09022

bLikr dh ik'ku pVdfu;ka] fo|qr


tLrsnkj bLikrh IYksV] rFkk pedhys
100 feeh ds dkoys ftudk O;kl 10
feeh ls de u gks lfgr

09023

,uksM;qDr] vYeksfu;e ik'ku dkoys


100 feeh eki ds dkoys ftudk O;kl
10 feeh ls de u gks ds lfgr

Rs.
16.70

21.40

09024

ik'ku ykS f da x pVdfu;ka

Fixing only Add if fixed


dsoy LFkkiu in repairs

S&F

09024
09024,

Fixing Add if
only fixed in
dsoy repairs

vk- o LFkk-

milk/ku
iz R ;s d

LFkkiu tksMsa+ ;fn


ejEer esa 09025 dkoys lkfdV ;k NYys] iRFkj]
LFkkfir
bZV dk;Z ;k dahV esa fcBkus ds
Rs.
fy;s xksy ;k oxZ fcBkoksa ds
;ksX; ;k NYys] dVko djus
o lhesV
a ls Hkjus lfgr] laifw kZ

09025 Bolt-sockets (or thimbles) Mild steel Brass Aluminium


for letting into stone, uje yksgk
ihry vYeksfu;e
brickwork or concrete
Rs.
Rs.
Rs.
Rs.
(to suit round or square
shoots) including cutting
mortices and cementing
20.20
27.20
23.10
16.70

in, complete
09026 Bolt staples for round or
square bolts (plates for

flush or other bolts)


13.60
36.00
26.60
5.40

5.50

1.60

HINGES
dCts

BUTT HINGES
EACH

09026 dkoys daqMs xksy ;k oxkZdkj


dkoyksa esa fcBkus ds fy;s likV
;k vU; dkoyksa ds fy;s IysVas
VDdjh dCts
iz R ;s d

Size of hinges in mm

dCtksa dh eki feeh esa


25
09027 Butt hinges, heavy
weight, cold rolled mild Rs.
15.60
steel, and fixed
09028 Ditto, medium weight,
14.20
ditto
11.30
09029 Ditto, light weight, ditto
09030 Butt hinges, cast brass,
with mild steel hinge
pin, bright polished and

fixed, typeB-11

40
Rs.

50
Rs.

65
Rs.

75
Rs.

100
Rs.

125
Rs.

16.00 19.10 22.10 25.40 35.50 42.60


15.40 16.10 20.30 23.70 32.00 37.90
14.20 16.00 17.80 22.50 29.70 33.20

80.10 93.00

09027
09027vrIr osfYyr uje bLikr ds Hkkjh
ctuh VDdjh dCts rFkk LFkkfir
09028
09028mi;qDZ r] e/;e ctu ds] mi;qDZ r
09029
09029mi;qZDr] gYds ctu ds] mi;qZDr
0 9030
9030<ys ihry ds VDdj dCts uje
yksgs ds dCtk fiu lfgr pdenkj
ikfyl fd;s gq;s ch&11 uewus ds
rFkk LFkkfir

170

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds ekhuh miknku
HINGES-Contd...
dCts tkjh
VDdjh dCts tkjh
iz R ;s d

BUTT HINGES-Contd...
Size of hinges in mm

EACH

dCtksa dh eki feeh esa


50

09031
09032
09033
09034
09035
09036
09037
09038
09039
09040

Ditto, but type B-12

Ditto, but type C-11

Ditto, but type C-12

Ditto, but type C-21

Ditto, but type C-22

Ditto, but type C-2 3

Ditto, but type D-l l

Ditto, but type E-l 1

Ditto, but type E-12


Butt hinges, extruded brass, with
mild steel hinge pin, bright polished and fixed, type B-11

09041
09042
09043
09044
09045

Ditto, but type B-12


Ditto, but type C-11
Ditto, but type C-12
Ditto, but type C-21
Ditto, but type C-22

09046
09047
09048
09049

Ditto, but type C-23


Ditto, but type D-l 1
Ditto, but type E-l 1
Ditto, but type E-12

09050 Butt hinges, extruded aluminium alloy with galvanised


mild steel hinge pin, anodised

and fixed, type B-21

09051 Ditto, but type B-22

09052 Ditto, but type C-21

09053 Ditto, but type C-22

09054 Ditto, but type D-22

09055 Ditto, but type E-22

09056 Fixing only butt hinges

09057 Add if hinges are fixed in repairs

65

75

Rs.
84.80

Rs.
90.70

Rs.
95.40

69.60

78.90

83.60

88.30
94.20

70.71

94.21

74.40

70.70
94.20
89.30

38.40

66.30

34.10

53.70

86.00

122.40

69.60

80.11

113.00

74.23

83.60

118.90

80.10

113.00
97.70

100

125

Rs.
Rs.
101.60 109.50
94.20
102.40
98.90
94.20

82.40
94.20
70.70

42.00
35.80

63.70
48.40

53.40

39.07
37.31

86.20

80.10

10.30
7.90

70.71

94.21

21.40
16.70

21.40
16.70

42.79
16.70
13.20

16.70
13.20

09051
09052
09053
09054
09055Z
09056
09057
09058

09058 Add to foregoing items if brass/


bronze hinge pin is provided in
lieu of mild steel hinge pin

09041
09042
09043
09044
09045
09046
09047
09048
09049
09050

121.20

45.70
28.50

09031
09032
09033
09034
09035
09036
09037
09038
09039
09040

2.90

4.70

5.90

7.00

8.20

mi;qZDr] fdUrq uewuk ch&12


mi;qZDr] fdUrq uewuk lh&11
mi;qZDr] fdUrq uewuk lh&12
mi;qZDr] fdUrq uewuk lh&21
mi;qZDr] fdUrq uewuk lh&22
mi;qZDr] fdUrq uewuk lh&23
mi;qZDr] fdUrq uewuk Mh&11
mi;qZDr] fdUrq uewuk bZ&11
mi;qZDr] fdUrq uewuk bZ&12
fuLdklu ihry ds VDdj dCts]
ch&11 uewus ds pednkj ikfyl o
uje yksgs dh dCtk fiu lfgr] rFkk
LFkkfir
mi;qZDr] fdUrq uewuk ch&12
mi;qZDr] fdUrq uewuk lh&11
mi;qZDr] fdUrq uewuk lh&12
mi;qZDr] fdUrq uewuk lh&21
mi;qZDr] fdUrq uewuk lh&22
mi;qZDr] fdUrq uewuk lh&23
mi;qZDr] fdUrq uewuk Mh&11
mi;qZDr] fdUrq uewuk bZ&11
mi;qZDr] fdUrq uewuk bZ&12
tLrsnkj uje bLikr dh dCtk fiu
VDdj dCts lfgr] vuksM;qDr
vY;qfefu;e feJ/kkrq ds fu"dklu
ch&21 uewus ds rFkk LFkkfir
mi;qZDr] fdUrq uewuk ch&22
mi;qZDr] fdUrq uewuk lh&21
mi;qZDr] fdUrq uewuk lh&22
mi;qZDr] fdUrq uewuk Mh&22
mi;qZDr] fdUrq uewuk bZ&22
VDdj dCts dk dsoy LFkkiu
tksMsa+ ;fn dCts ejEer esa LFkkfir
fd;s gSa
tksMsa+ ij dh enksa esa ;fn uje
bLikr dCts fiu ds LFkku ij
ihry@rkacs ds dCtk fiu yxk;s
x;s gSa

171

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds ekhuh miknku
HINGES-Contd...
dCts tkjh...
PARLIAMENT HINGES
EACH

ikfyZ ; keS a V dCts


iz R ;s d

Width of recess between flanges


(when open) in mm

dksjksa ds chp dh nwjh tc [kqys gksa feeh esa


65
Rs.
54.10

75
100
Rs.
Rs.
59.00 69.00

125
Rs.
77.80

150
Rs.
102.50

09059

dCts vrIr uje bLikr ds


laiwfkZ rFkk LFkkiu
09060 mi;qDZ r] fdUrq <yh ihry] pedhyh
138.00 147.20 182.40 188.78 205.90
ikfy'k fd;s gq, rFkk LFkkfir
09061 Ditto, but aluminium alloy
09061 mi;ZDq r] fdUrq vY;qfefu;e feJ/kkrq
69.00 77.80 101.00 157.10 175.60
anodised and fixed
,uksM;qDr rFkk LFkkfir
09062 Fixing only, items 09059 to
17.90 17.90 17.90 17.90 17.90 09062 dsoy LFkkiu] ensa 09059 ls 09061
09061
09063 tksMsa+ en 09059 ls 09061 esa ;fn
09063 Add to items 09059 to 09061
4.20
if fixed in repairs
ejEer esa LFkkfir
4.20 4.20
4.20
4.20
09059 S&F Parliament hinges, mild

steel cold rolled


09060 Ditto, but cast brass, bright

polished and fixed

CONTINUOUS (PIANO) HINGES


PER RUNNING METRE

09064 S & F Continuous (piano) hinges,


mild steel, bright finish or elec
trogalvanised

09065 Ditto, but of brass

09066 Fixing only items 09064 and 09065


09067 Add to items 09064 to 09066, if fixed

in repairs

iz f r ehVj

iYyksa dh pkSM+kbZ tc [kqys


gksa feeh esa
30
Rs.

40
Rs.

102.80
171.00
41.70

123.90
206.20
41.70

8.70

8.70

Length in mm

EACH

yEckbZ feeh esa

09070 Fixing only, items 09068 and 09069


09071 Add to items 09068 to 09070 if fixed in

repairs

lrr fi;kuks dCts

Width of flaps (when


open) in mm

TEE HINGES

09068 S&F Mild steel tee hinges, stove


enamelled black, medium type, and

fixed

09069 Ditto, but heavy type, ditto

csyuuqek

150
200
Rs.
Rs.
43.40 52.60
55.20 70.20
17.30 17.30

300
Rs.
63.40
89.00
18.50

4.50

4.50

4.50

09064 lrr fi;kuks dCts uje bLikr]


pedhyh lrg ;k fo|qr tLrsnkj
laiwfkZ rFkk LFkkiu
09065 mi;qZDr] fdUrq ihry ds
09066 dsoy LFkkiu ensa 09064 o 09065
09067 tksMs+a] en 09064 ls 09066 esa ;fn
ejEer esa Fkkfir

Vh dCts
09068

09069
09070
09071

iz R ;s d
uje yks g s ds Vh dCts rIr
,usey;qDr e/;e fdLe ds laiwfrZ
rFkk LFkkiu
mi;qDZ Rk] fdUrq Hkkjh fdLe] mi;qDZ r
dsoy LFkkiu ensa 09068 o 09069
tksMsa+] en 09068 ls 09070 esa ;fn
ejEer esa LFkkfir

172

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds ekhuh miknku
HINGES-Contd...
dCts tkjh...
mHk; f;k dekuh dCts

DOUBLE ACTING SPRING HINGES


EACH

S&F

vk- o LFkkSize of spring hinge in mm

dCts dh uki feeh esa


09072 Double action spring
hinges, mild steel with
steel wire spring, stove

enamelled, black
09073 Ditto, but brass, with
phosphor bronze wire

spring, bright polished


09074 Blank hinge, mild steel
stove enamelled, black,
for use alongwith mild
steel double action

spring hinges

100
Rs.

125
Rs.

150
Rs.

152.90

188.40

206.80

373.90

420.90

491.40

129.50

156.50

183.50

503.10

579.50

09075 Blank hinge, brass, bright


polished,
for
use
alongwith brass double
action spring hinges 426.70

Fixing Add if
only fixed in
dsoy repairs

iz R ;s d

LFkkiu tksMsa+ ;fn


ejEer esa
LFkkfir 09072 uje yksgs ds mHk; f;k dekuh
dCts] r`Ir ,usey;qDr] dkyh
Rs.
Rs.

bLikr rkj dekuh lfgr


21.40
5.50
09073 mi;qDZ r] ihry ds] QkLQj rkacs
dh rkj dekuh] pedhyh
21.40
5.50
ikfyk ds lkFk
09074 vHkklh /kqjh] uje yksgs ds r`Ir
,usey;qDr dkys uje yksgs
ds mHk; f;k dekuh dCts ds
lkFk ;ksx ds fy;s
21.40
6.40
09075 ihry ds nksgjh f;k dekuh
dCts ds lkFk ;ksx ds fy;s
ihry ds pedhyh ikfyk
21.40
6.40
fd;s vkHkklh /kq j h

SPRING FOR DOORS


njoktksa ds fy;s dekuh
EACH

S&F

Fixing
only

vk- o LFkk-

dsoy
LFkkiu
09076 300mm, ordinary rat tail
rod pattern springs
including roller and
roller plate complete

09077 375mm, ditto


09078 Add to items above if
fixed to stone/ concrete
chowkats with flat
iron 40x3 mm size 75 cm
long with necessary
bolts, etc. complete

Add if
fixed in
repairs

tksMsa+ ;fn
ejEer esa
LFkkfir

Mild steel

Brass

uje bLikr

ihry

Rs.

Rs.

Rs.

Rs.

95.40

165.90

19.00

5.50

118.90

195.30

19.00

5.50

75.30

iz R ;s d

09076 dekfu;ka jksyj o jksyj IysV


lfgr 300 feeh ds lk/kkj.k
likV NM+ rjhds dh lai.w kZ
09077 mi;qZDr] 375 feeh
09078 tksM]+as en 956 o 957 esa ;fn
vko;d dkoys vkfn lfgr]
40 3 feeh eki 75 lseh
yEch likV yksgs ds lkFk]
iRFkj@da hV pkS [ kVks a es a
LFkkfir djds laiwfrZ

SECTION 9

173

SECTION 9 BUILDERS HARDWARE


[k.M 9& fuekZrk ds e'khuh miknku
HANDLES
ew B s a gS U My
ewBsa Lohd`r izfr:i@ifj:i dh gksxhA

Handles shall be of pattern/design as approved.


EACH

iz R ;s d

S&F
vk- o- LFkkSize of handle in mm

ewB dk vkdkj feeh esa


75
09079 Cast iron or malleable cast iron
handles, cast type, stove Rs.
27.90
enamelled black
09080 Mild steel pressed handles, oval

type, stove enamelled black


20.80
09081 Brass handles, cast type,
46.70
polished bright
09082 Extruded brass handles,
fabricated type polished 64.30
09083 Aluminium handles, cast type,
26.70
anodised
09084 Extruded aluminium alloy
handles, fabricated type,
27.90
anodised
09085 Fixing only items 09079 to
7.90

09084
09086 Add to items 09079 to 09084 if
1.80
fixed in repairs

100

125

Rs.

Rs.

31.40

33.70

22.00

23.20

60.80

70.20

72.50

84.30

29.00

33.70

40.80

42.00

7.90

7.90

1.80

1.80

150

09079 ewB <yoka yksgs ;k fiVoka yksgs ds


<yoka uewuk] LVkso ,usey ;qDr

dkys
43.10
09080 eawB uje yksgs ds laihfMr vaMkdkj
uewuk o LVkso ,usey;qDr dkys
25.50
09081 ea w B ihry ds <yoka fdLe ds
pednkj ikfyk;qDr
84.30
09082 eaBw ihry fudklu ihry ds] x<kbZ
fdLe ds ikfyk;qDr
96.00
09083 eawB vY;qfefu;e ds <yoka fdLe o
,uksM;qDr
37.30
Rs.

09084 eaBw fu"dklu vY;qfefu;e feJ /kkrq


ds x<kbZ fdLe o ikfyk;qDr
49.00
09085 dsoy LFkkiu ensa 09079 ls 09084
7.90
1.80

09086 tksMsa+] enksa 09079 ls 09084 esa] ;fn


ejEer esa LFkkfir

LATCHES
vxZ y s
EACH

iz R ;s d

Size of latch in mm

vXkZys dh eki feeh esa


09087 Rim latch with two levers, of
75
mild steel body. stove enamelled
Rs.
finish; with brass knob or lever
140.20
handle and fixed
09088 Ditto, but of brass body,
208.10
polished bright
09089 Ditto but of aluminium alloy
120.70
body, anodised
09090 Fixing only, items 09087 to
29.10
09089
09091 Add to items 09087 to 09090 if
7.90
fixed in repairs

100

125

150

Rs.

Rs.

Rs.

112.10

133.00

135.20

232.80

269.80

294.80

137.80

156.30

183.20

29.10

29.10

29.10

7.90

7.90

7.90

09087 jhe vxZys nks yhoj] uje yksgs dh


dk;k] LVkso ,usey;qDr ifjd`fr
o ihry eaBw ;k yhoj gSM
a y lfgr]
rFkk LFkkfir
09088 mi;q Z D r] fdUrq ihry dk;k]
pednkj ikfyk
09089 mi;ZDq r] fdUrq vY;qfefu;e feJ/kkrq
dk;k ,uksM;qDr
09090 ds o y LFkkiu] ens a 09087 ls
09089
09091 tksMsa+] en 09087 ls 09090 esa ;fn
ejEer esa LFkkfir

174

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds e'khuh miknku
LATCHES Contd...
vxZys tkjh
R;s d

Length of latch in mm

EACH

yEckbZ feeh esa


65

75

100

Rs.

Rs.

Rs.

166.60

187.00

221.20

238.80

290.00

353.10

196.50

223.00

246.00

09095 Fixing only items 09092 to 09094

29.10

29.10

29.10

09096 Add to items 09092 to 09095 if

fixed in repairs

7.90

7.90

7.90

09092 Mortice latch with two levers


(vertical type), mild steel body and

fixed

09093 Ditto but of brass body


09094 Ditto but of aluminium, anodised

body

09092 nks yhoj ds vxZyh yEc uewuk uje


yksgs dh dk;k] ,oa LFkkfir
09093 mi;ZqDr] fdUrq ihry dk;k
09094 mi;ZDq r] fdUrq vY;qfefu;e] ,uksM;qDr
dk;k
09095 dsoy LFkkiu] ensa 09092 ls 09094
09096 tksMs+a] en 09092 ls 09095 esa ;fn
ejEer esa LFkkfir

LOCKS
rkys
Qyd IysVsa o nks pkfc;ka njksa esa kkfey gSaA

The rates include for escutcheon plates and two keys


S & F vk-

EACH

o LFkk-

Mild steel

Brass

Fixing Add if
only fixed in
Aluminium
repairs

uje yksgk

ihry

vy;qfefu;e LFkkiu

2 Lev- 4 Lev- 2 Lev- 4 Levers


ers
ers
ers

2 yhoj 4 yhoj 2 yhoj 4 yhoj 2 yhoj 4 yhoj


09097 Mortice lock,
vertical type, size

100 mm
09098 Ditto, size 65mm
09099 Ditto, size 75 mm
09100 Rebated mortice
lock, vertical type,

size 65 mm

09101 Ditto, size 75mm


09101ADitto, size 100mm
09102 Mortice night latch,

size 65 mm
09103 Ditto, size 75min
09103ADitto, size 100mm
09104 Locks, cupboard,
grade I, size 50

mm
09105 Ditto, size 65mm

09106 Ditto, size 75mm

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

217.70 298.70 379.80 542.00


182.20 223.30 289.20 315.70
197.00 229.90 319.20 369.10

270.50

93.50 101.80 144.80 162.70


147.70 169.30 206.30 211.90
161.00 177.30 223.10 271.00

95.80 106.50
107.80 115.70
114.80

215.00

tksM+as
;fn
ejEer
esa
LFkkfir

2 Lev- 4 Levers
ers

Rs.

R;s d

Rs.

50.20
55.50

16.70
16.70

55.50

16.70

12.90
12.90

3.40
3.40

12.90

3.40

10.60
10.60
10.60

15.90
15.90
15.90

09097 Hkhrjh rkys] eki 100


feeh] o yEc fdLe ds

09098 mi;qDZ r] izeki 65 feeh


09099 mi;ZDq r] izeki 75 feeh
09100 i[knkj Hkhrjh rkys] yEc
fdLe ds 65 feeh izekih
09101 mi;ZDq r] izeki 75 feeh
0 9101, mi;qDZ r] izeki 100 feeh
09102 Hkhrjh lqj{kk rkys izeki
65 feeh
09103 mi;ZDq r] izeki 75 feeh
09103, mi;qDZ r] izeki 100 feeh
09104 vYekjh rkys] Js.kh
1] izeki 50 feeh
09105 mi;qDZ r] izeki 65 feeh
09106 mi;ZDq r] izeki 75 feeh

SECTION 9

175

SECTION 9 BUILDERS HARDWARE


[k.M 9& fuekZrk ds e'khuh miknku
LOCKS Contd...
rkys tkjh
S & F vk-

EACH

o LFkk-

Mild steel

Brass

Fixing Add if
only fixed in
Aluminium
repairs

uje yksgk

ihry

vy;qfefu;e LFkkiu

2 Lev- 4 Lev- 2 Lev- 4 Levers


ers
ers
ers

Rs.

Rs.

Rs.

Rs.

88.80
91.80
96.80

Rs.

Rs.

98.20
131.40
102.80

tksM+as
;fn
ejEer
esa
LFkkfir

2 Lev- 4 Levers
ers

2 yhoj 4 yhoj 2 yhoj 4 yhoj 2 yhoj 4 yhoj


09107 Locks, drawer,
grade I, size 50

mm

09108 Ditto, size 65mm

09109 Ditto, size 75mm

R;s d

Rs.
12.90
10.60
10.60

Rs.
3.40
12.90
15.90

09107 njkt ds rkys] Js.kh 1]


izeki 50 feeh
09108 mi;qDZ r] izeki] 65 feeh
09109 mi;qDZ r] izeki] 75 feeh

FASTENERS AND STAYS


ca/kd rFkk rkusa
EACH

S&F

vk- o LFkkCast
iron
(malleable)
or mild
steel
09110 Casement stays, size
300mm, with hinged
joint and two plates,
with studs complete
09111 250mm ditto

09112 Add to items 09110


and 09111, if fixed to
steel sashes, including
drilling necessary
holes or welding
09113 Screw eye 10 to 12 mm

internal dia and fixe

Cast
brass

Aluminium

vy;qfefu;e

<yoka
ihry

dsoy tksM+sa ;fn


LFkkiu ejEer esa
LFkkfir

<yoka@fiVcka
;k uje yksgk
Rs.

Rs.

Rs.

Rs.

22.40

10.30

2.60

21.30

10.30

2.60

Rs.

09110 Qjes dh rkus]a dCtsnkj


iYyksa ds 300 feeh izeki]
dCtsnkj tksM]+ nks IysV
o es [ k lfgr la i w . kZ
rFkk LFkkfir
09111 250 feeh mi;qZDr
09112 tksM]+as en 09110 o 09111
esa ;fn yksgs ds iYys esa]
vko;d ojeh Nsn ;k
Vkdh lfgr LFkkfir gks

23.80
3.10

iz R ;s d

Fixing Add if
only fixed in
repairs

09113 is p vkf{k Hkhrjh O;kl


7.80

7.10

0.80

0.30

10 ls 12 feeh rFkk LFkkiuk

176

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds e'khuh miknku
FASTENERS AND STAYS Contd...
ca/kd rFkk rkusa tkjh
FANLIGHT PIVOTS AND
CATCHES

S&F

vk- o LFkkCast
iron
(malleable)
or mild
steel

PER SET

09114 Fanlight pivot with


plate size 25mmx 65
mm and suitable for
shutter of 30mm

thickness and fixed


09115 Ditto, but suitable for
shutter of 35 mm

thickness
09116 Ditto, but size 20mm
x50mm and suitable
for shutter of 25mm

thickness
09117 Fanlight catch with
14mm catch and

fixed

Cast
brass

Aluminium

vy;qfefu;e

<yoka
ihry

dsoy tksM+sa ;fn


LFkkiu ejEer esa
LFkkfir

<yoka@fiVoka
;k uje yksgk
Rs.
29.40

Rs.
87.50

Rs.
33.50

Rs.
19.40

Rs.
5.30

30.10

89.90

34.70

19.40

5.30

26.80

74.70

}kj jks kunku dhyd


rFkk [kVds

Fixing Add if
only fixed in
repairs

31.70

14.70

3.70

iz f r lew g

0 9 1 1 4 }kj jkskunku dhyd]


vkdkj 25x65 feeh rFkk
30 feeh eksVs dikVksa ds
fy;s mi;q D r] rFkk
LFkkiuk
0 9 1 1 5 mi;ZqDr] fdUrq 35 feeh
eksVs dikVksa ds mi;qDr

0 9 1 1 6 mi;ZqDr] vkdkj 20 X
50 feeh rFkk 25 fe eh
eksVs dikVksa ds fy;s mi;qDr

0 9 1 1 7 }kj jkskunku ds [kVds]


14 feeh xzkgh rFkk LFkkiuk
10.80

18.90

13.30

1.10

0.30

DRAWER PULLS AND HANDLES


njkt nLrk rFkk gSaMy
S&F

EACH

vk- o LFkkCast
iron or
mild steel
09118 Drawer pulls, 3 screw
plate with fixed dished
pull; 80 mm to 100mm

long
09119 Ditto, 4 screw plate ditto
09120 Drawer handles, projection
drop (50mm to 65mm) on

screwed plate
09121 Ditto, but projection ring
drop (40mm x 50mm),
ring on 4 screw plate
09122 Ditto, but flush drop (65
to 75mm grip) on 4 screw
plate, including letting

in

Brass

ihry

Fixing
only

Add if
fixed in
repairs

dsoy
LFkkiu

tksM+sa ;fn
ejEer esa
LFkkfir

<yoka yksgk ;k
uje yksgk

R;s d

0 9 1 1 8 njkt nLrs] jdkoh nLrs esa 80

Rs.

Rs.

Rs.

Rs.

27.00
33.40

42.30
49.90

7.00
7.60

1.80
1.80

31.10

48.80

7.60

1.80

37.00

61.70

7.60

1.80

42.9 0

54.60

7.60

1.80

ls 100 feeh yEcs jdkoh IysV


esa 3 isp ls LFkkiu

0 9 1 1 9 mi;qZDr] 4 isp IysV mi;ZqDr


09120 njkt gSM
a y isp yxh IysV ij

ur {ksid 50 ls 65 feeh

0 9 1 2 1 mi;qDZ r] fdUrq iz{ksi NYyk ur

40 X 50 feeh NYyk 4 isph


IysV ij
0 9 1 2 2 mi;qDZ r] fdUrq likV ur] 65
ls 75 feeh idM+ vUnj fcBkus
lfgr] pkj isph IysV ij

SECTION 9

177

SECTION 9 BUILDERS HARDWARE


[k.M 9& fuekZrk ds e'khuh miknku
HAT PEGS AND HOOKS
Vksih [kwaVh rFkk gqd
EACH

S&F

Fixing Add if
only fixed in
repairs

vk- o LFkkCast iron


Brass
or mild steel ihry

Aluminium

vy;qfefu;e

<yaok ;k uje
yksgk

R;s d

dsoy tksM+sa ;fn


LFkkiu ejEer esa
LFkkfir

09123 Hat pegs, solid body,


125mm to 175 mm

Rs.

Rs.

Rs.

Rs.

Rs.

19.50

28.90

23.00

5.40

4.20

09124 Hat and coat hooks,


solid body, 175mm to

250 mm

21.30

30.20

26.30

5.40

4.20

09125 Wardrobe
hooks
(single) 50mm to

60mm

14.80

26.60

27.10

5.40

4.20

0912
091233 Vksih Vkaxus dh [kwfa V;ka 125
ls 175 feeh dh Bksl dk;k
0912
091244 Vksih o dksV Vkaxus ds
gqd Bksl dk;k ds 175
ls 250 feeh ds
0912
091255 vYekjh ds gqd ,dy
50 ls 60 feeh ds

GATE AND SHUTTER, HOOKS AND EYES


QkVd o njokts] gqd] xok{k
EACH

S&F

Fixing Add if
only fixed in
repairs

vk- o LFkkMild steel, Brass


wire, type wire, type
I
I

uje bLikr ihry rkj]


rkj] uewuk 1 uewuk 1
09126 Gate and shutter, hooks

and eyes 75mm

Aluminium
plate type II

vy;qfefu;e]
IysV uewuk 2

R;s d

dsoy tksM+sa ;fn


LFkkiu ejEer esa
LFkkfir

Rs.

Rs.

Rs.

Rs.

Rs.

10.30

34.40

23.60

5.00

0.80

09127 Ditto, 100mm size


09128 Ditto, 125mm size

11.70

42.70

30.70

5.00

0.80

12.90

47.00

29.20

5.00

0.80

09129 Ditto, 150mm size


09130 Ditto, 200mm size

13.20

48.50

36.30

5.00

0.80

15.20

52.00

40.70

5.00

0.80

0912
091266 75 feeh QkVd o njokts
ds gqd o xok{k
0912
091277 mi;ZDq r] 100 feeh vkdkj
0912
091288 mi;qDZ r] 125 feeh vkdkj
0912
091299 mi;qDZ r] 150 feeh vkdkj
091
30 mi;qDZ r] 200 feeh vkdkj
09130

178

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds e'khuh miknku
KNOBS
nLrk
S&F

EACH

09131 40mm dia, cupboard knobs


fixed with nut, screw and
washer of mild steel, bright

finished
09132 Ditto,
but
of brass,

polished
09133 Ditto, but of aluminium,

anodised
09134 50mm dia, polished, hard
wood knobs fixed with

screws

R;s d

Fixing
only

Add if fixed in
repairs

dsoy
LFkkiu

tksM+sa ;fn ejEer


esa LFkkfir

Rs.

Rs.

Rs.

16.70

2.60

0.80

09131 40 feeh O;kl ds] pedhyh


ifjd`fr vYekjh esa nLrs ds
lkFk uV o ispksa ls LFkkfir

37.90

2.60

0.80

09132 mi;ZqDr] ihry ds] ikfyk;qDr

0.80

09133 mi;qDZ r] vY;qfefu;e] ,uksM;qDr


09134 50 feeh O;kl ds ikfyk;qDr]
nLrs dBksj ydM+h ispksa ls
LFkkfir

vk- o LFkk-

43.80

2.60

HASPS AND STAPLES


Nids vkSj daqMs
EACH

Size of hasp and staple in mm

R;s d

Nids vkSj dqaMks dk vkdkj feeh esa


09135 Hasp and staple, mild
steel, wire type, stove enamelled
black, including bolt to hinge
plate and fixed with screws
09136 Ditto, but safety type

09137 Hasp and staple, safety type,


brass with mild steel hinge pin
including bolt to hinge plate

and fixed with screws


09138 Ditto, but of aluminium

anodised

75

100

125

150

Rs.

Rs.

Rs.

Rs

27.40

30.70

32.70

36.20

23.20

24.60

25.90

30.50

34.00

36.40

39.30

48.10

28.10

30.50

32.60

36.40

12.90

12.90

12.90

12.90

2.60

2.60

2.60

2.60

09139 Fixing only of above items

09140 Add to items 09135 to 09139, if

fixed in repairs

09135 uje yksgs ds rkjh fdLe ds LVkso


,usey;qDr dkys dCtk IysV esa
dkoys lfgr Nids o dqaMs ispksa ls
LFkkfir
09136 mi;qZDr] fdUrq lqj{kk fdLe ds
09137 uje yksgs dh fiu] dkoys dlh dCth
IysV lfgr] ihry ds lqj{kk fdLe ds
Nids dqM
a s ispksa ls LFkkfir
09138 mi;q Z D r] fdUrq vY;q f efu;e
,uksM;qDr
09139 09135 ls 09138 esa dsoy LFkkiuk
09140 tksM+sa] en 09135 ls 09139 esa ;fn
ejEer esa LFkkfir

SECTION 9

179

SECTION 9 BUILDERS HARDWARE


[k.M 9& fuekZrk ds e'khuh miknku
HASPS AND STAPLES Contd...
Nids vkSj daqMs tkjh
EACH

S&F

Fixing
only

Add if fixed in
repairs

dsoy
LFkkiu

tksM+sa ;fn ejEer


esa LFkkfir

Rs.

Rs.

Rs.

25.30

5.30

1.80

vk- o LFkk-

09141 Brass knobs 35-40mm dia

R;s d

09141 ihry dk nLrk O;kl 35&40 feeh

CURTAIN RAILS
ijnksa dh iVfj;ka
PER RUNNING METRE

S&F

vk- o LFkk09142 Harrison rails, mild


steel, chromium plated
with fixing brackets,

stops, rollers etc.


09143 Ditto, but of anodised

aluminium alloy

fr ehVj

Fixing
only

Add if fixed in
repairs

dsoy
LFkkiu

tksM+sa ;fn ejEer


09142 gSjhku iVfj;ka] LFkkiu czSfdV]
esa LFkkfir
Rs.
cU/kd] jksyj vkfn lfgr] uje
yksgs dh ksfe;e eqyEek;qDr

Rs.

Rs.

78.40

18.50

100.00

18.50

1.80

09143 mi;q Z D r] fdUrq ,uks M ;q D r


vY;qfefu;e feJ /kkrq dh

1.80

FINGER PLATES
vaxqyh IysVsa
EACH

S&F

vk- o LFkkTransparent Aluminium


plastic sheet, anodised,
1mm thick
1mm thick

ikjn'kZd
09144 Finger plates 200 to IYkkfLVd pknj
300mm long and 80 to 1 feeh eksVh
100mm wide fixed with
brass chromium plated

screws

Fixing
only

Add if
fixed in
repairs

dsoy
LFkkiu

tksM+sa ;fn
ejEer esa
LFkkfir

vY;qfefu;e
,uksM;qDr
1feeh eksVh

Rs.

Rs.

Rs.

Rs.

44.20

61.80

8.90

1.80

R;s d

09144 vxay
q h IysVas 200 ls 300 feeh
yEch o 80 ls 100feeh pkSMh+ ihry
ksfe;e eqyEek;qDr ispksa ls dlh
gqbZ

180

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9& fuekZrk ds e'khuh miknku
FINGER PLATES Contd...
vaxqyh IysVsa tkjh...
KICKING PLATES
Bksdj IysVs tkjh...
PER SQUARE METRE

S&F

vk- o LFkk09145 Kicking plates, any size,


of galvanised iron sheet
lmm thick, fixed with

galvanised screws

fr oxZ ehVj

Fixing
only

Add if fixed in
repairs

dsoy
LFkkiu

tksM+sa ;fn ejEer 09145 Bksdj IysV] fdlh vkdkj dh 1


esa LFkkfir
feeh eksVh tLrh yksgs dh tLrh
Rs.
ispksa ls LFkkfir

Rs.

Rs.

422.40

144.20

39.70

TOWEL RAILS

rkSfy;k Vkaxus dh iVfj;ka


PER RUNNING
METRE

09146 Tubular towel rail 20mm

dia

S&F

vk- o LFkkBrass
chromium
plated

Aluminium
anodised,

ksfe;e
p<+h ihry

,uksM;qDr
vY;qfefu;e

Rs.

Rs.

235.40

119.80

Fixing
only

Add if
fixed in
repairs

dsoy
LFkkiu

tksM+sa ;fn
ejEer esa
LFkkfir

Rs.

Rs.

4.20

0.50

iz f r ehVj

09146 rkSfy;k iVfj;ka 20 feeh O;kl


dh xksykdkj

EACH

iz R ;s d

09147 Tubular towel rail, 20mm


dia, D type, 60cm long

between flanges

09147 rkSfy;k Vkaxus dh iVfj;ka iYyksa


ds chp 60 lseh yEch Mh Vkbi
20 feeh O;kl

268.60

180.40

4.20

0.50

iz f r tks M + k

PER PAIR

09148 Brackets for item 09146

185.60

74.00

9.40

1.60

09148 en 09146 ds fy;s czSfdV

181

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9 fuekZrk ds ekhuh miknku
FLOOR DOOR STOPPERS AND DOOR CATCHES
Q'kZ }kj jks/ku rFkk }kj [kVds

d }kj jks/kd dh njksa esa jcj VqdM+ksa dk oydfur kkfey gSA

(a) The rates for floor door stoppers include for vulcanised
rubber piece.
(b) The rates do not include for sinkings in floor for fixing
stoppers.
EACH

[k jks/ku dks fLFkj djus ds fy;s QkZ dh /kalkbZ kkfey ugha gSA

Overall length of cover plate

<kaih IysV dh iw.kZ yEckbZ

iz R ;s d

140 mm
Rs.
37.90

150mm
Rs.
42.60

09149 vY;qeqfu;e feJ /kkrq dh dk;k o thHk


,uksM;qDr }kj QkZ jks/ku ds dBksj cuh
yksgs dh dekuh lfgr] QkZ esa LFkkfir

09150 Ditto, but of brass body and tongue


with hard drawn steel spring

49.60

63.70

09150 mi;qDZ r] fdUrq ihry dh dk;k o thHk] dBksj


cuh yksgs dh dekuh lfgr

09151 Fixing only of items 09149 and

09151

16.70

16.70

09152 Add to items 09149, 09150 and

09151, if fixed in repairs

2.60

2.60

09149 Floor door stopper of aluminium


alloy body and tongue, anodised,
with hard drawn steel spring,

fixed in floor

09153 Ball catches with 8mm dia steel


ball, and brass body and striking
plate including letting in and

fixed

09151 en 09149 o 09151 esa dsoy LFkkiuk


09152 tksM]as+ en 09149] 09150 o 09151 ;fn ejEer
esa LFkkfir
09153 xksykdkj [kVds] lkFk esa 8 feeh O;kl bLikr
xksyk rFkk ihry dk;k o Bksdj IysV( vUnj

fcBkus lfgr rFkk LFkkfir

Rs.
34.10

DOOR CLOSER
}kj ca/kd
S&F

EACH

iz R ;s d

Fixing Add if
only fixed in
dsoy repairs

vk- o LFkk-

LFkkiu tksMsa+ ;fn


Cast iron Alumin- Aluminium
ejEer esa
body
ium (Die (extruded
LFkkfir
<ys yksgk cast) body section)
09154
dh dk;k vY;qfefu;e body
<yok dk;k vY;qfefu;e
,DlVwMsm
dk;k

09154 Door closer hydraulically


regulated,
designation No. 3,
universal type, suitable
for door shutters of 851
to 1000 mm in width
and of weight between Rs.
61 to 80 kg and fixed 454.10
09155 Door closer hydraulically
regulated,
designation No. 2,
universal type, suitable
for door shutters of 701
to 850 mm in width and
of weight between 36
to 60 kg and fixed
395.40

Rs.

Rs.

Rs.

Rs.

724.40

841.90

19.40

15.90

}kj ca / kd vuq e ks n u ua - 3]
lkoZtfud izdkj ds 851 ls 1000
feeh pksMs o 61 ls 80 fdyksxzke
chp ds otu ds }kj dikVksa ds
fy;s mi;qDr ty O;oLFkk }kjk
fu;af=r rFkk LFkkfir

09155 }kj ca/kd vueksnu ua- 2] 701 ls


850 feeh pksMs o otu 36 ls 60
fdyksxzke] lkoZtfud fdLe }kj
dikVksa ds fy;s mi;qDr ty
O;oLFkk }kjk fu;af=r rFkk LFkkfir
606.90

724.40

19.40

15.90

182

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9 fuekZrk ds ekhuh miknku
DOOR CLOSER-Contd....
}kj ca/kd tkjh
S&F

EACH

iz R ;s d

Fixing Add if
only fixed in
dsoy repairs

vk- o LFkk-

LFkkiu tksMsa+ ;fn


Cast iron Alumin- Aluminium
ejEer esa
body
ium (Die (extruded
LFkkfir
<ys yksgk cast) body section)
dh dk;k vY;qfefu;e body
09156 }kj ca/kd vuqeksnu ua- 1] lkoZtfud
<yok dk;k vY;qfefu;e
izdkj ds 700 feeh pkSM+kbZ o 35
,DlVwMsm
fdyksxkz e ctu rd ds }kj dikVksa
dk;k
ds fy;s mi;qDr ty O;oLFkk
Rs.
Rs.
Rs.
Rs.
Rs.
}kjk fu;af=r rFkk LFkkfir

09156 Door closer hydraulically regulated,


designation No. 1
universal
type,
suitable for door
shutters up to 700 mm
in width and of
weight
not more 348.40

than 35 kg and fixed

489.39

606.90

15.90 19.40

WIRE CLOTH AND WIRE NETTING


rkjh diM+k rFkk rkjtkyh
When fixed in panels of joinery the rates include for fixing
with beads supplied with joinery.
WIRE CLOTH
PER SQUARE METRE

S&F

vk- o
09157 Galvanised mild steel wire LFkkcloth, 0.63mm nominal dia of
wire and average width of
aperture 1.40mm and fixed with
Rs.
tinned tacks, or galvanised wire
235.10
staples
09158 Ditto, but 0.56mm nominal dia
of wire and average width of
215.40
aperture 1.18mm
09159 Ditto, but 0.56mm nominal dia
of wire and average width of
240.00
aperture 1.00mm

tc la;ksftr iYyksa esa LFkkfir gks rks njksa esa la;kstu esa vkbZ QfV~V;ksa
lfgr LFkkiu kkfey gSA
rkjh diM+k

Fixing only Add if fixed


dsoy LFkkiu in repairs

tksM+s ;fn
ejEer esa
LFkkfir
Rs.

Rs.

36.50

9.80

36.50

36.50

9.80

9.80

izfr oxZ ehVj


09157 tLrh uje yksgs s dk rkjh diM+k] rkj dk
ukHkh; O;kl 0-63 feeh rFkk fNnz dh
vkSlr pkSM+kbZ 1-40 feeh rFkk dVkbZnkj
Vkads ;k tLrh rkjh dqaMksa ls LFkkfir

09158 mi;ZqDr] fdUrq 0-56 ukHkh; rkj O;kl o


fNnz dh vkSlr pkSMk+bZ 1-18 feeh
09159 mi;qDZ r] fdUrq] 0-56 ukHkh; rkj O;kl o
fNnz dh vkSlr pkSM+kbZ 1-00 feeh

183

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9 fuekZrk ds ekhuh miknku
WIRE NETTING
rkj tkyh
PER SQUARE METRE

S&F

Fixing Add if
only fixed in
dsoy repairs

vk- o LFkkSize of mesh in mm

tkyh dk vkdkj feeh esa

fr oxZ ehVj

09160 Wire netting of galvanised


steel wire 1.40mm dia
fixed with tinned tacks of

wire staples
09161 Ditto, but 1.23mm dia
09162 Ditto, but 0.91 mm dia

12
Rs.

20
Rs.

25
Rs.

202.00

186.50

173.60

LFkkiu tksMsa+ ;fn


ejEer esa
LFkkfir 09160 tLrh rkj tkyh] 1-40 feeh
Rs.
Rs.
O;kl dybZnkj Vkads ;k tLrh
rkjh dqaM+ksa ls LFkkfir

28.80
7.10

191.60
155.50

176.20
145.10

165.80
129.60

28.80
28.80

7.10
7.10

09163 Ditto, but 0.71mm dia

141.30

127.50

114.10

28.80

7.10

09161 mi;qDZ r] fdUrq 1-23 feeh O;kl


09162 mi;qDZ r] fdUrq 0-91 feeh O;kl
09163 mi;qDZ r] fdUrq 0-71 feeh O;kl

STAINLESS STEEL WIRE NETTING


PER SQUARE METRE

S&F

Fixing Add if
only fixed in
dsoy repairs

vk- o LFkkSize of mesh in mm

tkyh dk vkdkj feeh esa


09164 Wire netting of stainless
steel wire 1.4mm dia
fixed with tinned tacks of
stainless steel wire

staples
09165 Ditto, but 1.23mm dia
09166 Ditto, but 0.91 mm dia
09167 Ditto, but 0.71mm dia

12
Rs.

20
Rs.

25
Rs.

248.50

235.60

235.60
222.70
209.80

LFkkiu tksMsa+ ;fn


ejEer esa
LFkkfir
Rs.

Rs.

222.70

28.80

7.10

222.70
209.80

209.80
196.80

28.80
28.80

7.10
7.10

189.20

183.90

28.80

7.10

ALUMINIUM ALLOY/STAINLESS STEEL WIRE CLOTH


vY;qfefu;e feJ/kkrq@taxjks/kh bLikr rkjh diM+k
When fixed in panels of joinery the rates include for fixing tc la;ksftr iYyksa esa LFkkfir gks rks njksa esa la;kstu esa vkbZ QfV~V;ksa
with beads supplied with joinery.
lfgr LFkkiu kkfey gSA
WIRE CLOTH
PER SQUARE METRE

S&F

vk- o
LFkk-

09168 Aluminium alloy wire cloth,


0.45mm nominal dia of wire
and average width of aperture
Rs.
1.40mm and fixed with
633.90
aluminium wire staples
09169 Stainless steel wire cloth.
0.36mm nominal dia of wire
and average width of aperture
1.40mm and fixed with
stainless steel wire staples 434.70

Fixing only Add if fixed


dsoy LFkkiu in repairs

tksMa+s ;fn
ejEer esa
LFkkfir
Rs.

Rs.

36.50

9.80

36.50

9.80

rkjh diM+k
izfr oxZ ehVj
09168 vY;qfefu;e feJ/kkrq dk rkjh diM+k]
rkj dk ukHkh; O;kl 0-45 feeh rFkk fNnz
dh vkSlr pkSMk+ bZ 1-40 feeh vY;qfefu;e
rkjh dqaMksa ls LFkkfir
09169 taxjks/kh bLikr dk rkjh diM+k] rkj dk
ukHkh; O;kl 0-36 feeh rFkk fNnz dh
vkSlr pkSMk+ bZ 1-40 feeh taxjks/kh bLikr
rkjh dqaMksa ls LFkkfir

184

SECTION 9

SECTION 9BUILDERS HARDWARE


[k.M 9 fuekZrk ds ekhuh miknku
FLOOR SPRING
Q'kZ fLizax
lk o Je

M&L

EACH

Rs.
09170 Double action floor spring
hydraulically regulated made
up of minimum 1.25 mm thick
aluminium alloy sheet
foundation box, main body
with stainless steel cover,
governing pivot made of brass,
other parts made of mild steel

heavy duty and fixed

iz R ;s d
09170 rjy O;oLFkk }kjk O;ofLFkr mHk; f;k
QZ k dekuh] 1-25 feeh eks V h
vY;qfefu;e feJ /kkrq dh pknj dk
uhao ckDl] eq[; dk;k LVsuysl LVhy
doj dh] xojfuax fioV czkl dh cuh]
nwljs fgLls uje yksgs ds cus] Hkkjh dk;Z
ds fy, cus ,ao LFkkiuA

1903.10

MATERIALS (Supplied only)


lkexzh dsoy vkiwfrZ
WIRE CLOTH
rkjh diM+k
PER SQUARE METRE

izfr oxZ ehVj

Rs.

09171 Galvanised steel wire cloth. 0.63


mm nominal dia of wire and
average width of aperture 1.40mm

09172 Ditto, but 0.56 mm nominal dia


of wire and average width of

aperture 1.18mm
09173 Ditto, but 0.56 mm nominal dia
of wire and average width of

aperture 1.00 mm

09171 tLrh yksgs dk rkjh diM+k ukHkh; O;kl


0-63 feeh o fNnz dh vkSlr pkSMk+ bZ 1-40
feeh
09172 mi;ZDq r] fdUrq rkj dk ukHkh; O;kl 0-56
feeh o fNnz dh vkSlr pkSMk+ bZ 1-18 feeh

189.20

170.40

09173 mi;ZDq r] fdUrq rkj dk ukHkh; O;kl 0-56


feeh o fNnz dh vkSlr pkSMk+ bZ 1-00 feeh

193.90

WIRE NETTING
rkj tkyh
PER SQUARE METRE

izfr oxZ ehVj

Size of mesh in mm

tkyh dk vkdkj feeh esa


12
Rs.

09174 Wire netting of galva nised


157.40
steel wire, 1.40mm dia
148.00
09175 Ditto, but 1.23mm dia
115.10
09176 Ditto, but 0.91mm dia
102.20
09177 Ditto, but 0.71mm dia

20
Rs.

25
Rs.

143.30

131.60

133.90
105.70

124.50
91.60

94.00

77.50

09174 tLrh yksgs ds rkj dh 1-40 feeh O;kl


dh rkj tkyh
09175 mi;qZDr] fdUrq 1-23 feeh O;kl
09176 mi;qZDr] fdUrq 0-91 feeh O;kl
09177 mi;qZDr] fdUrq 0-71 feeh O;kl

185

SECTION 10

STEEL, ALUMINIUM
AND
SECTION
10 IRON WORK
[k.M
10
bLikr]
yks
g
k
rFkk
vY;qIRON
fefu;eWORK
dk;Z
STEEL, ALUMINIUM AND
[k.M 10 bLikr] yksgk rFkk vY;qfefu;e dk;Z
SPECIAL CONDITIONS
fo'ks"k 'krsZa
10.1 Measurements

10-1 eki

10.1.1 Cast Iron Work : Before fixing cast iron articles in


position, the Contractor shall produce vouchers
showing weights of the articles for the signature of the
E.I.C. in token of his acceptance of the weights. These
signed vouchers shall be produced again at the time of
recording and check of the measurements of the work.
Where, however, the E.I.C. elects to check the weights
shown in the vouchers the Contractor shall without extra
charge, arrange for the necessary weighing instruments
etc. and weigh the articles, in the presence of the E.I.C.

10-1 <yoka bLikr dk;Z% <yoka bLikr dh oLrqvksa dks LFkkiu esa
LFkkfir djus ls igys] Bsdns kj mu okmpjksa dks ftuesa oLrqvksa dk
ot+u fn;k gqvk gks] otu dh Lohd`fr ds izek.k gsr]q izHkkjh vfHk;Urk
ds gLrk{kj gsrq izLrqr djsxkA ;g gLrk{kfjr okmpj eki dks ntZ
djrs le; o tkap djrs le; nksckjk izLrqr fd;s tk;sx
a As
fQj Hkh tgka izHkkjh vfHk;ark okmpjksa esa fn[kk;s x;s otu dh tkap djuk
pkgs] rks Bsdns kj rkSyus ds lk/kuksa vkfn dk fcuk vfrfjDr [kpZ ds
izcU/k djsxk rFkk izHkkjh vfHk;Urk dh ekStnw xh esa oLrqvksa dks rkSyx
s kA

10.1.2 Steel Work


1. The weights of steel sections, plates, bars, wire fabrics
etc shall be calculated from the tables given in the
relevant Indian Standards, some of which are
reproduced in Appendix A to this SSR. Where the
weight of any section, etc. is not given in the Indian
Standards, it shall be calculated on the basis of 7850 kg/
cu.m. No tolerance on account of rolling margin shall
be allowed on the nominal weights of steel sections, etc.
2. The weight of cleats, brackets, packing pieces, distance
pieces, bolts, nuts, washers, separators diaphragm,
gussets and fish plates, taking overall rectangular
dimension: etc. shall be added to the weight of
respective item.
3. In riveted work the weight of rivet (including heads)
shall be added to the weight of item.
4. No deduction shall be made for rivet/bolt holes.
Deduction shall be made if the area of a hole exceeds
0.02 sq.m and for notch if its area exceeds 0.05 sq.m.

10-1-2 yksgs ds dk;Z%


1 yksgs ds [k.Mks]a pknjks]a NM+k]as rkj <akpksa ds otu dh x.kuk lacfU/kr
Hkkjrh; ekud esa nh xbZ lacfU/kr rkfydk] ftlesa ls dqN dks bl
,l ,l vkj ds ifjfkV esa fn;k x;k gS] ds vuqlkj dh tk;sxhA
tgka fdlh [kaM vkfn dk otu Hkkjrh; ekud esa ugha fn;k x;k
gS mldh x.kuk 7850 fdxzke@?kueh ds vk/kkj ij gksxhA bLikr
[kaMk+ as ds ukeh; otu ij jksfyax dh dksbZ NwV ugha nh tk;sxhA
2 QUuh] cSzfdV] HkjkbZ [kaM] vUrj ifV~Vdk] dkoys] f<ofj;ka
oklZy fo;kstd] e/;iV] izdks.kh rFkk lai.w kZ vk;rkdkj ifjeki
dh tksM+ ifV~V;ka] lacfU/kr oLrq ds otu esa tksM+s tk;sxsA

3 dhyd dk;Z esa dhyd dk otu 'kh"kZ lfgr lacfU/kr oLrq ds


otu esa tksM+k tk;sxkA
4 dhyd@dkoys ds Nsnksa dh dksbZ dVkSrh ugh gksxhA dVkSrh rc
gksxh tc Nsn dk {ks=Qy 0-02 oxZehVj ls vf/kd gks] rFkk [kkaps
ds fy, ;fn mldk {ks=Qy 0-05 oeh ls vf/kd gSA
5. In welded work, the weight of weld metal shall not be 5 VadkbZ dk;Z esa Vkafdr /kkrq dk otu lacfU/kr oLrq ds otu esa
added to the respective items.
ugh tksMk+ tk;sxkA
6. For other type of opening like holes for service pipe 6 vU; izdkj ds fyojksa tSls lsok uyksa vkfn ds Nsnksa ds fy;s
etc.. deduction shall be made if its area exceeds 0.1
dVkSrh dh tk;sxh] ;fn mldk {ks=Qy 0-1 oeh ls vf/kd gSA
sq.m.

7.

Weights shall be worked out to nearest kg.

10.1.3 Steel reinforcement shall be measured as fixed to


nearest 0.5 cm. Authorised overlaps, cranks, chairs and
separators shall be measured and hooks girthed in
calculating the total weight. The weight of tying wire and
weight of welds (where reinforcement is welded), shall
not be measured. The nominal size of a deformed steel bar
(i.e. bar diameter) is equivalent to diameter of a plain
round bar of corresponding size.

7 ot+u] fudVre fdxzk rd fudkyk tk;sxkA


10-1-3 bLikr izoyu Lohd`r dh eki tSlk LFkkfir gS ds fudVre
0-5 lseh rd yh tk;sxhA ijh p<+kos] eksM]+ dqflZ;ka rFkk foHkktdksa
dks ekik tk;sxk rFkk dls gq;s gqd dqy ot+u esa tqMsaxsA rkjca/ku o
Vkads tgka izoyu dks Vkadk yxk gS dk ot+u ugha tqMx
+s kA vxf<+r
bLikr lyk[k dk ukHkh; eki vFkkZr lyk[k dk O;kl leku eki
dh lknk xksy lyk[k ds O;kl ds cjkcj gksxkA

186

SECTION 10

STEEL, ALUMINIUM AND IRON WORK


[k.M 10 bLikr] yksgk rFkk vY;qfefu;e dk;Z
SPECIAL CONDITIONSContd..
fo'ks"k 'krsZ tkjh
10.1.4 Expanded metal and hard drawn steel wire fabric 10-1-4 foLrkfjr cjQh /kkrq o dBksj dlh rkj tkyh ,oa Vkafdr
and welded steel wire fabric shall be measured net in bLikr rkj tkyh oxZ ehVj esa fo'kq+) ekih tk;saxh rFkk otu dh
square metres and weight calculated. Authorised laps x.kuk gksxhA vuqeksfnr m<+ko ekis tk;saxsA 0-2 oxZ eh ls cM+s [kqys
shall be measured. Openings exc 0.2 sq.m. shall be LFkku ?kVk;s tk;sx
a sA
deducted.

10.1.5 Steel Rolling Shutters : Height shall be measured


from the bottom of the lintel to the finished floor cill level.
Width shall be measured inclusive of the width of the
side guides.

0-1-5 bLikr ds yisVoka 'kVj


'kVj% pkbZ] fyaVy ry ls laiwfjr
10-1-5
Q'kZ / fly ry rd ekih tk;sxhA pkSMk+ bZ ik'oZ fu;a=dksa dh pkSMk+ bZ
lfgr ekih tk;sxhA

10.1.6 Collapsible Steel Gates : Height shall be measured


from the finished floor level to the top of the gate. Width
shall be measured from outside to outside of the end fixed
channels in open position of the gate.

10-1-6 fuikrh fleVok bLikr QkVd% pkbZ laiwfjr Q'kZ


ry ls QkVd 'kh"kZ rd ekih tk;sxhA pkSM+kbZ] [kqys QkVd esa var
esa yxh pSuyksa ds ckgj ls ckgj ls cgkj rd ekih tk;sxhA

10.1.7 Steel Doors, Windows and Ventilators : The width


and the height shall be measured overall from out to out
of frame to the nearest 0.5cm. Composite units shall be
measured as under :(a) Side hung, bottom or top hung and centre hung
portions : measured out to out of the casement frame;

10-1-7 bLikr ds njokts] f[kM+fd;ka o jks'kunku% pkSM+kbZ o


pkbZ se ds ckgj ls ckgj rd laiw.kZ 0-5 lseh rd ekih tk;sXkh
A la;kstd vaXkks dh eki bl izdkj gksxh%&

d ik'koZ yVdu] ry ;k 'kh"kZ yVdu rFkk dsUnz yVdu Hkkxksa dks


vk/kkj pkS[kVs ds ckgj ls ckgj rd ekik tk;sxkA
(b) Fixed type portions : the overall measurement of the [k LFkkfir fdLe ds Hkkx% la;kstu vaxksa dh lai.w kZ eki ?kVk ik'koZ
composite unit less the area of side hung, bottom or
yVdu] ry ;k 'kh"kZ yVdu o dsUnz yVdu Hkkx
top hung and centre hung portions.

10.1.8 Anodised aluminium doors, windows and


ventilators:
(a) The width and height shall be measured from out to
out of frame of shutter to the nearest 0.5 cm.

10-1-8 ,uksMhd`r] vY;qefq u;e njokts] f[kM+fd;ka o jks'kunku%

10.2 Rates

10-2 njsa

10.2.1 The rates include for:

10-2-1 njksa esa fuEu 'kkfey gSa%&


d fojfpr lkeku dks dk;Z LFky ij mrkjuk] vUnj j[kuk] mBkuk
o LFkkiu djukA
[k dkVihV dj visf{kr eki] vkd`fr] o :i esa ykuk] ojes ls Nsn
djuk] dluk] fNnz fudkyuk] ispksa dks yxkuk] HkjkbZ vkfn rFkk
fdlh Hkh izdkj dh dk;Zd'q kyrk] ftldh lajpuk laifw k cukoV
o bLikr o yksgs ds dk;Z dks lgh] okLrfod o cf<+;k rjhds ls
LFkkfir djus esa vko';drk gks ldrh gSA

d pkSM+kbZ o apkbZ] dikV ds pkS[kVs ds ckgj ls ckgj rd ekih


tk;sxhA
(b) Aluminium section, anodisation, testing of [k vY;qfefu;e [kaM] ,uksMhd`r ,uksMhdj.k dh tkap vkfn( dikVksa
anodisation etc., fixing of shutters shall be all as
dk LFkkiu lHkh( ,l ,l vkj Hkkx&I dh mi/kkjk 10-37 iz"B 10described in clause 215 on page 10.19 of SSR part
19
fofunsZ'ku ds vuqlkj gksaxsA
I Specification.

(a) Unloading fabricated work at site, getting in, hoisting


and fixing.
(b) All forgings reducing to required size, shape and
figure; drilling, tapping, punching, countersinking
for screws, filling, etc. and every description of
workmanship that may be necessary to fabricate,
finish, erect and fix in position steel and iron work in
a good, substantial and perfect manner.

187

SECTION 10

STEEL, ALUMINIUM AND IRON WORK


[k.M 10 bLikr] yksgk rFkk vY;qfefu;e dk;Z
SPECIAL CONDITIONSContd..
fo'ks"k 'krsZ tkjh

uksV% Nsn dVkbZ] [kkaps fudkyuk vkfn iqjkus dahV bZV ;k


iRFkj lajpukvksa esa f>jh fudkyuk] bLikr@yksgs ds dk;Z dh
LFkkiuk ds ckn mUgsa Bhd djus ds dk;ksaZ dks mi;qDr [kaMksa ds
vUrxZr izFkd ekik tk;sxk flok; en 10063 ls 10083 rd
ftuesa iqjkus o u;s nksuksa esa LFkkiu 'kkfey gSA ifj"d`fr elkys
;k dahV ds feykos ls gksxh tks 1%2 ds lhesVa elkys ;k ih lh
lh 1%2%4 B1 ds feykos ls de dk ugha gksxk rFkk izHkkjh vfHk;ark
dh larqf"V ds vuqlkj gksxhA
(c) Spikes, nails and screws required (weight shall not x dkaVs] dhysa o visf{kr isp ctu ugha tqMs+xk
NoteCutting holes, mortices, etc. chases in old
concrete, brick or stone structures and making good
after steel/iron work is fixed, shall be measured
separately under the appropriate Sections except for
items 10063 to 10083 which include fixing to both
new or old work. The making good shall be done with
a mix of mortar or concrete not leaner than cement
mortar 1:2 or PCC 1:2:4 type B1 and to the satisfaction
of E.I.C.
be added).
(d) Neatly cut and filed notches and true square ends,
including planing to sheared ends of plates, angles,
etc. (where a butting against each other), for
transmission of stresses.
(e) All necessary templates, patterns, moulds, etc.

?k lQkbZ ls dVs o Hkjs [kkapksa o lkns oxhZ; Nksj] IysVks]a lfj;ksa vkfn
ds Nksjksa ds la;kstu lfgr tgka ,d nwljs ls VDdj izfroy
lapj.k ds fy;sA

10.2.2 Holding down bolts and anchor bolts including


nuts and washers shall be measured separately by
weight.

10-2-2 LFkkid dkoys] fLFkjd dkoys( f<ofj;ka oklZy lfgr] dk


ctu vyx ls fy;k tk;sxkA

10.2.3 Supplied and fixed rates for black sheets (plain


and corrugated) shall be increased by 10 percent of the
difference between 'Supplied and fixed and Fixing
only rates where galvanised sheets Grade of Coating
450 are provided.

10-2-3 ^vkiwfrZ o LFkkfir* dh njsa] dkyh pknjksa lknk ;k ygfj;k


dh njksa dks ^vkiqfrZ o LFkkfir*] vkSj ^dsoy LFkkiu* ds vUrj dk 10%
c<+kbZ tk;sx
a h] tgka Js.kh 450 dksfVax dh tLrh pknjsa yxkbZ xbZ gSAa

10.2.4 Lamp Posts, Fencing Posts and the like : The


rates include for transporting and distributing posts at
required intervals and placing and holding in true
position, etc., while ramming around or concreting in
foundation (excavation in post holes, return fill and
ram and concreting, if any, shall be measured
separately).
Steel fittings to cast iron articles are to be measured separately.

10-2-4 fctyh [kaHks] lhek [kaHks rFkk leku dk;Z% njksa esa
[kaMksa dh <qykbZ] vkisf{kr nwfj;ksa ij j[kuk] [kM+k djuk] lh/kh voLFkk
esa Fkkeuk vkfn pkjksa vksj dh HkjkbZ ;k uhoksa esa dahV fcNkuk 'kkfey
gS] xM~<s [kksnuk] HkjkbZ BqdkbZ o dahV HkjkbZ ;fn gks rks izFkd ekih
tk;sxhA

p lHkh vko';d] vk/kkj iV~V] vkd`fr;ka] lkaps vkfnA

188

SECTION 10

STEEL, ALUMINIUM AND IRON WORK


[k.M 10 bLikr] yksgk rFkk vY;qfefu;e dk;Z
CAST IRON WORK
<ys yksgs ds dk;Z

<ys yksgs ds oLrqvksa eas bLikr ds miLdjksa dks izFkd ekik tk;sxkA
PER KILOGRAM

Articles n exc 5 kg
each

10001 Cast iron work grade FG


150, unmachined, in
brackets,
gully traps,
gratings, railing, frames,
manhole covers, fire and
soot doors, dampers, stop
valve boxes, gate stops,
parts of ranges, balusters

and similar articles


10002 Cast iron work grade FG
150, machined, in pulleys

and similar articles

oLrq izR;sd 5 fdls vuf/kd


S&F

vk o LFkk

10001 ,Q th 150 Js.kh ds fcuk e'khu


cus <ys yksgs ds dk;Z] cSfz dVks]a ^xqyh ViS ]
tkfy;ka] iVfj;ka] pkS[kVs esugksy <Ddu]
S&F
Supplied
only
>qdkoh o <ykoka njokts] voeand] jksd
vk o LFkk dsoy vkiwfkZ okYo cDls] QkVd jks/kd] oxhZd`r Hkkx
taxys ds lfj;k rFkk leku oLrqvksa esa
oLrq izR;sd 5 fdls vf/kd

Supplied
only

dsoy
vkiwfkZ

Rs.

Rs.

70.70

70.40

iz f r fdyks x z k e

Articles exc 5 kg
each

Rs.

Rs.

54.60

68.30

54.60

56.00

67.90

54.70

10002 e'khuh ,Q th 150 Js.kh ds


xjkjh o leku oLrqvksa esa <ys yksgs ds
dk;Z

MILD STEEL WORKS (MISCELLANEOUS)


uje bLikr dk;Z fefJr
(a) The rates include for riveting and/or welding as directed
and fixing with screws, bolts, etc. complete

d bu njksa es [kkafpr ,oa@;k Vkafdr] vkns'kkuqlkj rFkk ispksa]


dkoys vkfn yxkdj laiw.kZ djuk 'kkfey gSA

(b) Rates for provision of window guard bars under item


10003 do not include for drilling holes in timber.

[k en 1155 ds vUrxZr f[kM+dh jf{kr lfj;ksa ds izko/kku esa ydM+h


esa ojeh Nsn 'kkfey ugha gSA

PER KILOGRAM

S&F

vk- o LFkk10003 Chimney bars (straight or


camber); bearing bars; tongues
or water bars for window frames;
window guard bars, plain, let in
and fixed independently in
wooden frames, L or T section
supports for shelves etc. and
similar articles conforming to

Fe-290 Gde E-165


10004 Hand rails, half round or other
stock section or core for wooden
hand-rail straight portion,
drilled and countersunk for
balusters running bars, for
doors, balusters, nosing to steps
including embeding in concrete
and screwing etc. wind ties for
roof including securing bolts;

iz f r fdyks x z k e

Fabrication Fixing
only
only

Rs.

Rs.

dsoy 10003 fpeuh lfj;s lh/ks ;k mHkkjh /kkjd lfj;s]


f[kM+dh seksa ds thHkh ;k ty lfj;s]
LFkkiu
ydM+h ds pkS[kVksa esa vdsys LFkkfir lknk
Rs.
f[kM+dh jf{kr lfj;s] 'ksYQksa vkfn ds ,y
;k Vh ifjPNsnh lgkjs vkfn rFkk leku
oLrq;sa] Fe-290 Gde E-165 ds vuq:i

69.70

5.40

3.00

dsoy
lajpuk

10004 v/kZ xksy ;k vU; Lda/k dkV dh gLFk


iVfj;ka] ;k ydM+h dh gLFk iVfj;ksa ds
lh/ks Hkkxksa ds fy;s ksM] NksVs vk/kkjksa ds
fy;s ojfer o izfr?kalh lfj;s] njoktksa]
f[kM+fd;ksa] lhf<+;ksa ds vxzHkkx ds fy;s]
dahV esa yxkus o isp vkfn dhy dlkbZ
ckM+ yxkus esa vkns'kkuqlkj vkd`fr ds

189

SECTION 10

STEEL, ALUMINIUM AND IRON WORK


[k.M 10 bLikr] yksgk rFkk vY;qfefu;e dk;Z
MILD STEEL WORKS (MISCELLANEOUS)Contd...
uje bLikr dk;Z fefJr tkjh
izfr fdyksxzke

PER KILOGRAM
posts and struts in fencing
including cutting tops to shape
as directed, drilling holes,
notching for wire, etc.; flat iron
fillets (for securing wire mesh
etc.) including all necessary
drilling, bolting or riveting, etc.,
and similar work conforming to
Fe-290 Gde E-165
10005 Blank
10006 Extra only on Item 10004 for
curved or ramped portions of
hand rails to required shape or
figure (curved, ramped or scroll
portions only measured)
10007 Framed work such as grills,
gratings, etc.. with ends of bars
shouldered and/or riveted,
or forged into spikes; framed
guard bars; barred iron doors;
ladders; framed balusters; walk
ways; railings; framework of
water tanks and similar work
con- forming to Fe.290.Gde-E-165

10008 Extra only over Item 10007 for


portions framed and hung as
gates, including pintle hinges, stops,
hand-made sliding bolts, etc.
10009 Add to item 10007 for ornamental

and intricate design


10010 Framed brackets of angles or tees
with web and flanges cut to
shape, drilled and countersunk
for screw, including bending and
welding angles, as necessary,
gusset plates, riveting, etc.. n exc
10 kg each brackets, conforming
to Fe.290.Gde-E-165 (Brackets
over 10 kg each to be measured

under 'Structural Steel')

dsoy
lajpuk

dsoy
LFkkiu

Rs.

Rs.

Rs.

fy;s 'kh"kZ dVkbZ] ojeh dk;Z] dkoys dlkbZ


;k fjosVu vkfn lfgr Vkafpr tkyh
vkfn dh idM+ ds fy;s likV yksgs dh
ifV~V;ka rFkk leku dk;Z tks Fe-290
Gde E-165 ds vuq:i gksa

70.30

5.70

5.37

S&F

vk- o LFkk-

8.60

Fabrication Fixing
only
only

10005 [kkyh
10006 vfrfjDr dsoy en 10004 esa o ;k
dqM
a yh Hkkxksa dks visf{kr vkdkj o vkd`fr
nsus ds fy;s o] daM
q fyr] ;k <ykoh
Hkkxksa dks dsoy ekik tk;sxk

8.60

87.10

19.20

9.30

9.30

12.60

12.60

66.10

15.8

8.70

6.60

10007 Qjesnkj dk;Z tSls fxzysa] tkfy;ka vkfn


ftuds lfj;ksa ds Nksj >ys gq;s vFkok@;k
fjosfVr ;k dkaVksa esa Qalk;s gq;s] lkafpr
jf{kr lfj;s( lfj;snkj yksgs ds njokts]
lhf<+;ks]a Qjesnkj NksVs [kaHks] ikjiFk] jsfyxs]a
tyVafd;ksa ds Qjes dk;Z rFkk leku
dk;Z tks Fe.290.Gde-E-165 ds
vuq:i gksa
10008 vfrfjDr dsoy en 10007 esa] Qjesnkj]
<yoka Hkkxksa ds fy;s tSls jksdksa lfgr
QkVd gLr cuh pV[kfu;ka] dhfyd dCts]
jks/kd vkfn
10009 tksM+sa en 10007 esa] ltkoVh o tfVy
vfHkdYi ds fy;s
10010 lfj;s ;k Vhiksa dh Qjesnkj czSfdV rFkk
isp ds fy;s vkd`fr esa dVs LQkjh] ojehr
o izfr vory t:jr ds vuqlkj eqMsa+
gq;s Vkafpr dks.k laxe iVjh fjosfVr
vkfn] cSzfdV 10 fdxzke ls vf/kd ugha
Fe.290.Gde-E-165 ds vuq:i izR;sd
10 fdxzke ls vf/kd dh cSzfdV] lajpuk
bLikr ds vUrxZr ekih tk;sxh

190

SECTION 10

STEEL, ALUMINIUM AND IRON WORK


[k.M 10 bLikr] yksgk rFkk vY;qfefu;e dk;Z
MILD STEEL WORKS (MISCELLANEOUS)Contd...
uje bLikr dk;Z fefJr tkjh
PER KILOGRAM
10011 Tie bars with screwed ends,
nuts, washers and mild steel
plates for walls, chimneys, roofs,
arches, etc. king rods and
straining bolts confomiing to Fe
290 Gde-E-165
10012 Bands, straps, supports or stays
for rainwater, ventilating pipes,
including bolts, if required:
hooks (stay), heavy, for large
gates; hook and pintle hinges:
large hasps and staples; chains;
hand made sliding bolts; clamps;
hold fasts; wall ties; hooks for
hanging fans; plain angle cleats
for securing purlins to wood
trusses or rafters; knee piece
inserts; two way and three way
straps, plate washers and similar
small articles conforming to

Fe-290 Gde-E-165
10013 Extra over item 10012, where
straps, etc. have screwed, ends
including keys, cotters, wedges,
etc. for timber trusses and
similar work conforming to Fe
290 Gde-E-165
10014 Purpose made butt hinges
conforming to Fe-290 Gde-E-165
suitable for fixing to stone/
concrete door and window
frames (Fixing only shall be

measured separately)

S&F

vk- o LFkk-

Fabrication Fixing
only
only

dsoy
x<+kbZ
Rs.

Rs.

56.20

8.00

101.30

24.00

8.90

7.50

91.80

24.40

izfr fdyksxzke

dsoy 10011 pwM+hnkj Nksj f<ofj;ka] cklZyksa ds lkFk


LFkkiu
ca/kd lfj;s rFkk uje bLikr dh nhokjks]a
Rs.
fpefu;ksa] Nrksa] esgjkoksa vkfn dh IysVksa
e/; NM+sa o f[kapkoh dkoys] Fe-290
3.60
Gde-E-165 ds vuq:i
10012 ijukyksa] laokrh uyksa ds] ;fn vko';d
gks dkoys lfgr] ifV~V;ka] Qhrs] lgkjs
;k LFkki( cM+s QkVd ds Hkkjh gqd LFkki(
gqd o dhyd dCts( yEcs Nids o dqaMs(
tathjs] gkFk dh cuh pV[kfu;ka] f'kdat]s
gksYMQkLV] [kawfV;ka] ia[ks Vkaxus ds gqd]
dkSafp;ksa] dfM+;ksa ds okksa dh etcwrh ds
fy;s likV lfj;s QfUu;ka( fuos'kh tkuq[kaM]
f}iFkh o f=iFkh Qhrk IysV ds cklZy
rFkk leku NksVh oLrq;sa] Fe-290 GdeE-165 ds vuq:i

8.30

10013 vfrfjDr en 10012 ij tgka ydM+h dh


dSafp;ksa rFkk leku dk;Z ds fy;s iV~Vs
vkfn] pkfc;k] Qkuh] QfUu;ka lfgr
pqM+hnkj fdukjsa ds gksa( Fe-290 Gde-E165 ds vuq:i
10014 iRFkj@dahV ds njoktksa f[kM+fd;ksa esa
LFkkiu ds ms'; ls gh cus VDdj dCts
Fe-290 Gde-E-165 ds vuq:i dsoy
LFkkiu izFkd ekik tk;sxk

SECTION 10

191

SECTION 10 STEEL, ALUMINIUM AND IRON WORK


[k.M 10& bLikr] yksgk rFkk vY;qfefu;e dk;Z
SCREW BOLTS AND NUTS ETC.
ispnkj pwM+hnkj dkoysa rFkk f<ofj;ka vkfn
Length of ordinary bolts shall be measured from the underside of
the head to the end of shank; length of double ended bolts and
lewis bolts shall be measured overall.
PER KILOGRAM
10015 Mild steel screw bolts
(machine made) with
hexagonal or square
heads at one end and
screwed the other, or
screwed both ends, each
screwed end to be fitted
with washers and one
hexagonal or square
nut, n exc 5cm long
10016 Ditto, but length of bolt
exc 5cm but n exc 10cm

long
10017 Ditto, but length of bolt
exc 10cm and n exc

15cm long
10018 Ditto, but length of bolt
exc 15cm and n exc

22.5cm long
10019 Ditto, but length of bolt
exc 22.5cm and n exc

30cm long

PER KILOGRAM

lkekU; dkcyksa dh eki] muds 'kh"kZ ds uhps dh vksj ls /kM+ ds fljs


rd dh tk;sxhA nksgjs fljs okys ;k uksdnkj dkoyksa dks lai.w kZ yEckbZ
esa ekik tk;sxkA

Supplied and fixed

vkiwfrZ o LFkkiuk
Diameter of neck in mm

/kM+ dk O;kl feeh esa


5 to 10
Rs.

11 to 15 16 to 20
Rs.
Rs.

93.00

89.00

77.00

17.00

4.70

89.50

80.70

75.90

12.70

4.70

87.20

79.00

73.00

17.00

5.50

80.00

77.80

70.30

8.50

4.20

81.10

76.70

66.00

8.50

2.60

Supplied and fixed

vkiwfrZ o LFkkiuk
10020 Mild steel rag or lewis
bolts, screwed one end,
with hexagonal or square
nuts and washers, the
other end enlarged and
jagged or lewised, n

exc 15cm long


10021 Ditto, but length of bolt
exc 15cm and n exc

30cm long
10022 Ditto, but length of bolt

exc 30 cm long

iz f r fdyks x z k e
10015 uje bLikr ds 5 lseh vuf/kd
yEckbZ ds ispnkj dCts e'khuh
LFkkiu tksMsa+ ;fn
,d fljk N% ;k pkj dkS.kh;
ejEer esa
rFkk nwljk pwMh+ nkj ;k nksuksa fljs
LFkkfir
pwM+hnkj( nksuksa fljksa ds fy;s N%
Rs.
Rs.
;k pkj dks.kh; f<ofj;ka o oklZy

Fixing Add if
only fixed in
dsoy repairs

Diameter of neck in mm

xzhok dk O;kl feeh esa


12
Rs.

20
Rs.

25
Rs.

76.80

72.30

76.80
74.50

Fixing Add if
only fixed in
dsoy repairs

LFkkiu tksMsa+ ;fn


ejEer esa
LFkkfir
Rs.

Rs.

67.80

13.50

4.50

72.30

67.80

13.50

4.50

72.30

65.10

10.40

3.60

10016 mi;qZDr] fdUrq yEckbZ 5 lseh


ls vf/kd fdUrq 10 lseh ls
vuf/kd
10017 mi;qZDr] fdUrq yEckbZ 10 lseh
ls vf/kd fdUrq 15 lseh ls
vuf/kd
10018 mi;qZDr] fdUrq yEckbZ 15 lseh
ls vf/kd fdUrq 22-5 lseh ls
vuf/kd
10019 mi;qZDr] fdUrq yEckbZ 22-5
lseh ls vf/kd fdUrq 30 lseh
ls vuf/kd
iz f r fdyks x z k e
10020
10020uje bLikr ds nkarsnkj ;k
uksdnkj 15 lseh vuf/kd yECkkbZ
ds dkoys( N% ;k pkj dks.kh;
f<ofj;ka o cklZyksa lfgr ,d
fljk nkarns kj o nwljk fljk yEcku
o nkarsnkj ;k uksdnkj
10021 mi;qZDr] dkoys dh yEckbZ 15
lseh ls vf/kd fdUrq 30 lseh ls
vuf/kd
10022 mi;qZDr] dkoys dh yEckbZ 30
lseh ls vf/kd

192

SECTION 10

SECTION 10 STEEL, ALUMINIUM AND IRON WORK


[k.M 10& bLikr] yksgk rFkk vY;qfefu;e dk;Z
SCREW BOLTS AND NUTS ETC. Contd...
ispnkj pwM+hnkj dkoysa rFkk f<ofj;ka vkfn tkjh
Hand made plate washers, if indicated, will be measured under
item 10012.

PER KILOGRAM

;fn gkFk dh cuh IysV ck'kj crkbZ xbZ gS rks og en 10012 ds


vUrxZr ekih tk;saxhA

S&F

Fabrication only

vk- o LFkk-

dsoy lajpuk

10023 Mild steel bolts.


Diameter of neck in mm
purpose made.
xzhok dk O;kl feeh esa
with hexagonal or
n. exc Exc
Exc n. exc Exc
square head one
12 12 n. 20 n.
12
12 n.
end and screwed
12
ls
exc
exc
12
ls
exc
the other, or
25 vuf/kd 20
screwed both ends; vuf/kd 20
12 ls 20 ls
12 ls
each screwed end
vf/kd vf/kd
vf/kd
to be fitted with
washers and one
20 ls 25 ls
20 ls
hexagonal
or
vuf/kd vuf/kd
vuf/kd
square nut. exc Rs.
Rs.
Rs.
Rs.
Rs.
91.80 85.00 73.20 23.30 21.20
30cm long

Fixing Add
only if in
dsoy repairs

LFkkiu
Exc
20 n.
exc
25

20 ls
vf/kd
25 ls
vuf/kd
Rs.
14.00

tksMas+
;fn
ejEer
esa
LFkkiuk

iz f r fdyks x z k e
10023 iz;kstu fufeZr 30 lseh ls vf/
kd ds uje yksgs ds dkoys] ,d
fljk N% ;k pkj dks.kh; 'kh"kZ o
nwljk pwMh+ nkj ;k nksuksa fljs
pwMh+ nkj gj pwMh+ nkj fljk ,d
N% ;k pkj dks.kh; f<ojh o
oklZy ls dlk gqvk

Rs.
Rs.
13.10 2.20

STEEL SHEET FLUE PIPES


bLikr pknj ds fpeuh uy

d fpeuh uyksa dh eki] milk/kuksa ds chp dh NksVh yEckbZ;ksa


lfgr laiw.kZ dh tk;sxhA
[k if;ksa vkfn dh yEckbZ] uy dh yEckbZ esa ugha tqM+sxh fdUrq
izFkd ekih tk;sxhA
(c) Rates include for all cutting and waste and short lengths; x njksa esa lHkh izdkj dh dVkbZ o Nhtu rFkk NksVh yEckbZ;ka
but supports, clamps, stays, etc. for securing pipes to wall
'kkfey gSa fdUrq lgkjs] f'kdats] jksd vkfn uyksa dks nhokj esa
shall be measured separately.
lqjf{kr djus ds fy;s( dks izFkd ekik tk;sxkA
(d) Thickness of steel sheeting for making pipes shall be as ?k uy cukus ds fy;s bLikr dh pknj dh eksVkbZ ogh gksxh tks
specified in SSR Part I.
,l ,l vkj Hkkx&1 esa nh xbZ gSA
(a) Flue pipes shall be measured overall including all short
lengths between accessories.
(b) The length of bends, etc. shall not be included in length of
piping, but shall be measured separately.

SECTION 10

193

SECTION 10 STEEL, ALUMINIUM AND IRON WORK


[k.M 10& bLikr] yksgk rFkk vY;qfefu;e dk;Z
STEEL SHEET FLUE PIPES-Contd....
bLikr pknj ds fpeuh uy tkjh
PER RUNNING METRE

S&F

iz f r ehVj

Fixing Add if
only fixed in
dsoy repairs

vk- o LFkkDiameter of pipe in mm

uy dk O;kl feeh esa

LFkkiu tksMsa+ ;fn


ejEer esa
10024 Flue pipes of mild steel
100
150
200
250
LFkkfir 10024 uje yksgs dh dkyh pknj ds uy(
sheet, black, in suitable
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
izHkkjh vfHk;ark }kjk Lohd`r mi;qDr
lengths as approved by
yEckbZ ds rFkk nhokjksa esa LFkkfir
209.60 348.30 448.90 669.00 14.70
5.10
the E.I.C. fixed to walls
EACH
10025 Bends or elbows (square
or raking) with sliding
soot door complete of
mild steel sheet, black 94.00 152.80 211.50 270.30
10026 Cowls (with 3 stays),
riveted to and including
15 cm length of flue
70.50 99.90 129.25 164.50
pipes, of ditto
10027 Elbows canister with
soot door, of flue pipes
117.50 188.00 235.00 340.70
of ditto

S&F

PER KILOGRAM

vk- o
LFkk10028 Roof plates with sleeve
pieces riveted or welded
thereto, and similar
roof and ceiling

connections

6.80

2.80

3.60

1.30

iz R ;s d
10025 eksM+ o dksgfu;ka pkSdksj ;k frjNs
uje yksgs dh dkyh pknj ds ljdoka
dkys }kj lfgr laiw.kZ
10026 Vksih] 3 jksd ds lkFk fjosfVr o
15 lseh yEckbZ ds fpeuh uy ds
lfgr mi;qZDr
10027 dksguh dsfuLrj] fpeuh uy ds
dkys eq[k lfgr fpeuh uy mi;qDZ r

9.10

3.00

izfr fdyksxzke

Fabric- Fixing Add if fixed


ation only only in repairs

dsoy
lajpuk

dsoy
LFkkiu

tksM+s ;fn
ejEer esa
LFkkfir

Rs.

Rs.

Rs.

Rs.

76.60

18.50

9.80

2.80

10028
10028fjosfVr ;k Vkafdr cktw [kaM ds lkFk Nr
IysV leku Nr vkSj lhfyax la;kstu

MILD STEEL SHEETING, PLAIN & CORRUGATED

uje yksgs dh pknj dk;Z] lery rFkk iukjhnkj ygfj;k


(a) The net area covered after deducting all openings exceeding
0.2 sq.m. shall be measured, without any extra allowance
for laps, etc.
(b) Irregular pieces fixed in repairs shall be measured as
smallest rectangles from which the pieces can be cut.

d <dk gqvk {ks= 0-2 oeh ls cM+h focjksa dks ?kVkdj] mHkkj vkfn
dk vfrfjDr yxk;s fcuk fo'kq ekik tk;sxkA

[k lq/kkj dk;Z esa yxs vleku VqdM+kas dks ml lcls NksVs vk;rkdkj
VqdM+s ls ekik tk;sxk ftlesa ls og VqdM+k cu ldrk gSA
(c) The rates given are for the black sheets.
x nh xbZ njsa dkyh pknj ds fy;s gSaA
(d) The rates include for all cutting and waste. Supports, clamps, ?k njksa esa lc izdkj dh dVkbZ o Nhtu 'kkfey gSA vkyEc]
stays, etc. for securing shall be measured separately.
f'kdats] jksd vkfn lqj{kk lk/ku] izFkd ekis tk;saxsA

194

SECTION 10

SECTION 10 STEEL, ALUMINIUM AND IRON WORK


[k.M 10& bLikr] yksgk rFkk vY;qfefu;e dk;Z
MILD STEEL SHEETING, PLAIN & CORRUGATED-Contd...

uje yksgs dh pknj dk;Z] lery rFkk iukjhnkj ygfj;k tkjh

PER SQUARE METRE


10029 Mild steel, plain, black
sheet in wall cladding,
steel gates and similar
work, cut to size, holes
punched; including
round headed screws,
clout nails or rivets
and fixed to wood or
steel framing with
plain 40 mm lap joints
with riveted or welded
seams, including bending
or turning up, mitred

angles, etc. as required


10030 Ditto, but in hearths;
covering to door shut
ters; covering to door
chowkats
(frames);
chullah hoods; water
tanks; water troughs;
ducts; urinal troughs
and funnels, etc. cut to
size edges beaded if
directed, holes punched;
including round headed
screws, clout nails or
rivets and fixed to wood
or steel members, etc.,
with plain 40 mm lap
joints or welded/
riveted seams including
bending, turning up,
mitred angles, stopped
ends, outlets, etc. as

required
10031 Add to items 10029 and
10030 if corrugated

steel sheets are used

S&F

vk- o LFkkThickness of sheet in mm

pknj eksVkbZ feeh esa


0.63

0.80

1.00

1.25

Rs.

Rs.

Rs.

Rs.

1002
100299 uje yksgs dh lery dkyh
pknj ds nhokjh vkoj.k] bLikrh
tksMsa+ ;fn pknj
QkVd rFkk leku dk;ksZ esa
ejEer esa jfgr
vkdkj esa dVh Nsn fudkyuk]
1.60
LFkkfir
xksy fljksa okys ispks]a crklh
Rs.
Rs.
dhyksa ;k fjfiVksa rFkk lhi Vkads
ds p<+koh tksMk+ as lfgr ydM+h
;k bLikr ds pkS[kVksa esa LFkkfir
o vko';drkuqlkj eqMh+ ;k
?kqek;s x;s feVj dkV vkfn

321.50 368.50

462.50 556.50 697.50

10.70

40.20

389.00 436.00

530.00 624.00 765.00

33.00

117.00

3.60

10.30

46.90

10031A Add to items 10029


and 10030 if sheeting
is welded to frame

53.00

65.30

76.60

izfr oxZ ehVj

Add if Except
fixed in sheetrepairs ing

95.80

100
30 mi;qZDr] HkV~Vh ryksa] }kjksa ds
10030
dikVksa }kj pkS[kVksa se ds
vkoj.k( pwYgs dh Vksih] ty
Vafd;ka] ty fudklksa] ukfy;ksa
ew= fudklksa] fpefu;ksa vkfn
es]a funZ'kkuqlkj vkdkj esa dVs]
fdukjs xksV yxs] Nsn fudys
xksy fljksa okys ispksa orklh
dhyksa ;k fjfiVksa ;k lhe Vkads
ds p<+koh tksM+ksa lfgr ydM+h
;k bLikr ds vaxksa esa LFkkfir(
yxkuk] eksM+uk] ?kqekuk] feVj
dkV caf/kr fdukjs] fudkl eksjh
vkfn tSlh vko';drk gks

31 tksM+sa ] en 10029 o 1190 esa


100
10031
;fn ygfj;k pknjksa dk iz;ksx

fd;k x;k gSA


31, tksM]+as en 10029 o 1190 esa
100
10031,
;fn pknjh dk;Z se esa Vkafdr

gS

195

SECTION 10

SECTION 10 STEEL, ALUMINIUM AND IRON WORK


[k.M 10 bLikr] yksgk rFkk vY;qfefu;e dk;Z
RAKING CUTTING, ETC. ON STEEL SHEET WORK
voueu jsfdax dVkbZ vkfn bLikr pknj dk;Z ij
iz f r ehVj

PER RUNNING METRE


10032 Raking or circular cutting; cutting holes for
pipes, notchings. etc. including waste on plain

sheeting (any thickness)


10033 Ditto, but on corrugated sheeting (any

thickness)

Rs.
31.80

1 0032 voueu ;k xksykdkj dVkbZ] uyksa esa Nsn dVkbZ] [kkapd


s kjh
vkfn lery pknj ij Nhtu lfgr dksbZ eksVkbZ

1 0033 mi;qZDr] fdUrq iukjhnkj pknj dk;Z ij dksbZ eksVkbZ

35.70

STEEL REINFORCEMENT FOR CONCRETE


dahV ds fy;s bLikr izoyu
The rates include for fixing and for bracing, supporting or bu njksa esa LFkkiu o vkoU/ku] voLFkku esa lgkjs ;k vU;Fkk etcwr
otherwise holding firmly in position so that the placing and idM+ ftlls dahV dh HkjkbZ o tHkko vius LFkku ls gV u tk;s
ramming of concrete will not displace it. Rates also include for
'kkfey gSA tgka dahV xB~Vks@
a fi.Mksa esa nh xbZ gS mls Bhd fcBkuk
straightening where reinforcement is supplied in rolls/coils.
Hkh njksa esa 'kkfey gSA
iz f r fdyks x z k e

PER KILOGRAM
10034 Mild steel bars 10mm
dia and over, cut to
length, bent to shape
required, including
cranking, bending
spirally for hooping
for columns, hooking
ends and binding
with and including
mild steel wire
(annealed) not less
than 0.9mm dia or
securing with clips

Round bars

xksy lfj;s

Gd.I, IS- Fe-410-W


432 (Part I) (Gde.E-250)
Part- I
quality-A or
Fe 290 (Gde E-165)

Deformed TMT
or twisted bars
bars
Vh,eVh

Rs

Rs

Rs

47.90

47.90

47.90

10035 Ditto, but 6mm to

8mm dia.

48.50

48.50

48.50

10036 Ditto, but 5mm dia


and over upto and
including 10mm dia
in stirrups, spacers

and binders

49.10

49.10

49.10

Except
steel bars

1 0034 10 feeh ;k vf/kd O;kl


ds uje yksgs ds lfj;s
bLikr lfj;k
yEckbZ esa dVs visf{kr]
lfj;k jfgr
vkdkj esa eqM]+s dt fudkys]
dkyeksa ds fy, liZ.k ;k
fdukjksa ij vadqlh yxh
Rs
Rs
rFkk de ls de 0-9 feeh
O;kl ds bLikrh rkj ls
cka/ks ;k fpefV;ka yxkdj
lqjf{kr fd;s gq,] dksfV var%
vuq:i
48.60
5.40
1 0035 mi;qZDr] fdUrq 6 feeh ls
8 feeh O;kl] dksfV vr%
49.10
5.90
vuq:i
1 0036 mi;qZDr] fdUrq 5 feeh ;k
vf/kd 10 feeh rd lfgr
jdkoks a ] vUrjkyks a o
49.70
6.50
ifV~V;ksa esa

HARD DRAWN STEEL WIRE FABRIC IN REINFORCEMENT


izoyu esa dBksj xfBr bLikr rkjhiV
The rates include for straightening, raking or circular njksa esa lh/kk djuk] eksMu
+ k ;k xksykdkj dVkbZ djuk o Nhtu 'kkfey gSA

cutting and waste.


Weight per square metre
iz f r fdyks x z k e
PER KILOGRAM
N exc 4kg Exc 4 kg
1
0037
dBks
j
df"kZ
r
rkj iV( yEckbZ esa dVs] visf{kr
10037 Hard drawn steel wire fabric cut to vuf/kd 4
4 fdxzk0
lengths, bent to shape required and fdxzk0
vkdkj esa eqMas+ rFkk de ls de 0-9 feeh O;kl
ls vf/kd
tying with and including mild steel wire
Rs.
Rs.
ds uje yksgs ds rkjksa ris gq;s ls ca/ks dh vkiwfrZ
(annealed) not less than 0.9mm in dia
djuk o izoyu esa LFkkfir djuk

64.00
65.70
supplied and fixed in reinforcemnt
8.50
11.50 1 0038 mi;qZDr] fdUrq dsoy LFkkiu

10038 Ditto, but fixing only

196

SECTION 10

SECTION 10 STEEL, ALUMINIUM AND IRON WORK


[k.M 10& bLikr] yksgk rFkk vY;qfefu;e dk;Z
STRUCTURAL STEEL WORK
la j pukRed bLikr dk;Z
(a) All rolled steel section (Beams, channels, angles, tees, etc.)
shall be of dimensions and weights as indicated and of one
length within the usual rolling limits.

(b) The rates given below (except 10039) allow for cutting to
dead length where required, notching, drilling, fitting,
riveting and/or welding or connecting with bolts and nuts
(including rivets or bolts and nuts), providing and fitting
angle cleats, fish plates, gusset plates etc., also for wedging,
plumbing, truing up and fixing complete.

[k

(c) The rates also include for drilling the members for site
connections; but site drilling to existing steel work shall be
measured separately.
(d) Any cast iron work in connection with structural steel work
shall be measured separately.

x
?k

S&F

PER KILOGRAM
Rolled mild steel in:
10039Joist, channel, angle, or tee sections,
fixed independently, without
connecting plates, etc. (cut to
ordinary lengths
i.e. within
20mm of the length indicated)
10040Rolled sections as in main and
cross beams, hip and jack rafters;
purlins where connected
to
common rafters and running rails
and guides for sliding doors;
fixed with angle cleats or other

connecting plates
10041Plate girder or single stanchions,
built up of one beam or channel
section with flange plates, caps,
bases. splices, angle brackets,
cleats and other connections
10042Compound
girders
and
stanchions, lattice girders, aerial
masts, staging for water tanks and
the like including caps, bases,
splices etc. built up from two or more
beam or channel sections or angles
with plates, including all lattice bars,

stiffeners, gusset plates, etc.


10043Plates (plain or chequered)
channels, square cut or notched
(ordinary and counter sunk)
forming holes, without any

attachment

vkiwfrZ o LFkkiuk
Fe 410 Fe-290 Fe-410(Gde E- W(Gde-W
E-250)
(Gde- 165)
qualityE- 250)
B
qualityA-

Rs.
Rs.
49.50 48.20

Rs.
50.70

56.20 55.00

57.40

56.10 54.80

57.30

62.00 60.80

63.30

56.10 57.10

57.50

lHkh jksYM csfyr bLikr [kaM /kju] pSuy] dks.k] Vh vkfn


bafxr ifjeki o otu ds gksx
a s rFkk ,d yEckbZ lkekU; jksfyr
lhek esa gksxhA
uhps dh rkfydk dh njsa 10039 dk NksMd
+ j tgka vko';d
gks fuf"; yEckbZ esa dVkbZ] [kkapk cukbZ ojekbZ] tqM+kbZ]
fjosVu ,oa@;k Vkadu ;k dkoys f<ofj;ksa ls tqM+kbZ fjfiV
;k dkoys f<ofj;ksa lfgr dks.kh; xqVds fQlIysV] lxae
IysV vkfn dh vkiwfrZ vkSj QUuh yxkbZ] uy dk;Z lkafpr o
LFkkiu laiwfrZ dh Hkh vuqefr nsrh gSaA
vaxksa ds LFkku la;kstu esa ojeh dk;Z 'kkfey gS fdUrq fo|eku
bLrki dk;Z esa ojeh dk;Z dks izFkd ekik tk;sxkA
lajpuk bLikr dk;ksZ esa fdlh Hkh <ys yksgs ds dk;Z dks izFkd
ekik tk;sxkA
Fabri Ereccation tion
only fixing
only

izfr fdyksxzke

fyiVoka uje bLikr%


sdsoy dsoy 10039
10039dM+h] iz.kky dks.k ;k T [kaM fcuk la;kstu
lajpuk jpuk o
IysV vkfn ds Lora= :i ls LFkkfir
LFkkiuk
lkekU; yEckbZ esa dVh ;kfu bafxr
Rs.
Rs.
1.00
3.40 yEckbZ ds 20 feeh ds vUnj
1 0040
0040eq[; o dSaph 'kgrhjksa ds tSls yisVoka
[ka M ] iq V ~ B s o tS d /kkjd( lkekU;
/kkjdksa ls tqM+s rFkk ljdoka njoktksa
dh likV iVfj;ks a o xkbM ,a x y
xq V dks a ;k vU; la ; ks t u Iys V ks a ds
3.40
7.30 lkFk LFkkfir
1 0041
0041IysV xMZj ;k ,dy /kjfu;ka ,d'kgrhj
;k pSuy esa yxk;s gq;s] dksjnkj IysVksa]
Vksfi;ksa] vk/kkjksa] xqaFks gq;s lfj;s] fozdsV

lfj;s] xqVds rFkk vU; la;kstu


3.40
5.60
1 0042
0042la;Dq r xMZj o /kjfu;ka] >a>jh xkMZj]
,fj;y ekLV] tyVa f d;ks a ds
vk/kkj] rFkk Vksih] vk/kkj] tksM+ vkfn
lfgr leku dk;Z nks ;k vf/kd
'kgrhj ;k iz.kky [kaMksa ;k IysV lfgr
lfj;s] o lHkh >a>jh NM+ksa] laxe
11.10 4.20 ifV~ V ;ks a ] :{k lfj;ks a vkfn lfgr
1 0043
0043Iys V s a lknk ;k [kka p s n kj ufydk;s a
pkS d ks j dVh ;k lka f pr lk/kkj.k o
fcuk fdlh 'ka d q [ kkr fcuk fdlh

4.40
3.70
milk/ku ds Ns n cus gq ; s

197

SECTION 10

SECTION 10 STEEL, ALUMINIUM AND IRON WORK


[k.M 10& bLikr] yksgk rFkk vY;qfefu;e dk;Z
STRUCTURAL STEEL WORK Contd...
lajpukRed bLikr dk;Z tkjh
Table Contd..
PER KILOGRAM
Rolled mild steel in :
10044 Ditto, with riveted, bolted or

welded attachment
10045 Rolled sections as in framing
for cladding, glazing and the
like fixed with angle cleats and

connecting plates, etc.


10046 Roof trusses (framed), trussed,
purlins, crane gantries, rails and
fastenings and heavy bracket
framing (Beam, tee, angle, channel
or flat sections) including
distance pieces, cleats etc.
10047 Stairs (framed) including
stringers, treades, landing,
balusters, hand rails etc. including cleats, brackets, etc.

complete
10048 Framed work as in doors or
gates of angle or other section
with gusset plates, rails,
braces, etc., complete, drilled for
fixing of steel sheeting or other
covering. Doors, etc. to be
prepared for hanging or sliding
with and including either hooks
and hinges or steel hanging
door fittings (exclusive of steel
sheeting or other covering,
running rails and guides) and
hanging; also fastening and

fixing complete

Rs.

Rs.

Rs.

Rs.

71.30

70.00

72.40

13.30 7.20

55.80

54.50

57.00

7.00

62.70

61.50

64.00

10.70 7.90

66.80

65.60

68.00

14.90 6.60

59.20

58.00

60.50

7.70

S&F
10049 Steel work in tubular trusses vk0 o
including special shaped LFkk
washer etc. complete using
ERW or induction butt welded
tubes conforming to I. S.1161- Rs.
81.40
1979 grade St.-240
10050 Add to any of the foregoing
items if structural steel is M & L
painted one shop coat of zinc lkexzh ,oa
chromate primer paint Rs.
(including preparation of
surface) at Contractors 0.60
workshop before fabrication

iz f r fdyks x z k e

Rs.

6.10

5.10

fyiVoka uje bLikr%


10044 mi;qDZ r] fdUrq fjosfVr] dkoys yxs
;k Vkafpr midj.k
10045 Qjescna h] 'kh'kkxhjh o leku dk;ksZ
tSls yisVok [kaM] yksgs ds xqVdksa
o la;kstu IysV vkfn ls LFkkfir
10046 Nr dSfa p;ka pkS[kVsnkj dSpa hnkj ifyZu]a s
su xSf<j;ka] iVfj;ka o ca/kuksa rFkk
Hkkjh czfS dV Qjekcanh 'kgrhj] Vh]
dks.k] pSuy ;k likV [kaM vUrj
ifV~Vdk] xqVds vkfn lfgr
10047 lh<h Qjes n kj( lh<+ h iknks a ]
yfM+ ; ks a ] pkS f d;ks a] ta x yks a ] gLr
iVfj;ksa lfgr rFkk xqVds] czSfdVksa
vkfn lfgr la i w . kZ
10048 Qjesnkj dk;Z tSls lfj;s ;k vU;
dkVksa ds njokts ;k QkVd laxe
IysV] iVfj;ksa xksVksa vkfn ds lkFk
laiw.kZ( bLikr pknj ;k vU;
vkoj.kksa dks yxkus ds fy;s ojHkkbZ
dk;Z lfgr@njoktksa vkfn dks
yVdkus ;k ljdkus dk izcU/k ;k
rks gqd o dCts ;k bLikr ds
yVdu }kj miLdjksa bLikr
pknjhdj.k ;k vU; vkoj.k] likV
iVfj;ka o xkbM NksM+dj ds lkFk
yVdkuk Hkh rFkk dluk o laiq.kZ
LFkkiu

Fabrication Erection and


only
fixing only

10049 bLikr dk;Z] ukfynkj dSafp;ksa esa


dsoy lajpuk dsoy jpuk o
fo'ks"k vkdkj dh ok'kj vkfn lfgr]
LFkkiu
ERW ;k izjd
s dqM
a s Vkafdr ufy;ka
tks
Hkkjrh;
ekud
1161&1979 Js.kh
Rs.
Rs.
St- 240 ls izekf.kr
10.70
7.70

Except Paint

Je

jksxu jfgr
Rs.
0.10

10050 ij dh fdlh Hkh en esa tksM+sa]


;fn bekjrh bLikr ij Bsdnkj ds
dkj[kkus esa lajpuk ls igys tLrh
dkseVs vLrjh isUV dh is'ksoj ijr
yxkbZ xbZ gks lrg lTtk lfgr

198

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
EXPANDED METAL AND WELDED STEEL WIRE FABRIC IN PARTITIONS, ETC.
foHkktuksa esa cjQh foLrkfjr tkyh rFkk >yh gqbZ Vkafdr rkj iV
(a) The rates include for straightening rolls of sheets, and
raking or circular cutting and waste.
(b) When expanded metal or fabric is fixed with flat iron, wood
fillets or beads, these shall be measured separately.;

EXPANDED METAL
PER KILOGRAM
10051 Expanded metal, cut to length,
bent to shape required and
tying with and including
annealed mild steel wire not
less than 0.9mm dia or fixing
with galvanised steel staples
supplied and fixed complete
to wood or steel members

10052 Ditto, fixing only


STEEL WIRE FABRIC
10053 Welded steel wire fabric
supplied and fixed complete
to wood or steel members
10054 Ditto, fixing only

d
[k

bu njksa es]a xVBksa ;k pknjksa dks lh/kk djuk rFkk frjNh ;k


xksy dVkbZ djuk Nhtu 'kkfey gSA
tc foLrkfjr /kkrq ;k iV] likV yksg]s ydM+h dh fxfV~V;ksa
;k xV~Vksa ds lkFk yxkbZ tkrs gSa] rks mUgsa izFkd ekik
tk;sxkA

Weight per square metre

foLrkfjr /kkrq

Hkkj izfr oxZ ehVj

iz f r fdyks x z k e

N exc 4 kg

Exc 4 kg

93.50
20.10

95.10
23.00

100.10

110.50

43.40

55.00

vuf/kd 4 fdxzk- vf/kd 4 fdxzk- 10051 foLrkfjr /kkrq ; visf{kr yEckbZ esa dVh o
vkdkj esa eqMh+ rFkk /kkrq ikuh p<+s uje /kkrq
Rs.
Rs.
ds rkjksa ;k tLrh bLikr ds 0-9 feeh ls de
ugha] dqaMkssa ls ca/kh tkyh dh vkiwfrZ djuk
rFkk ydMh ;k bLikr ds vaxksa es]a lai.w kZr;k
LFkkfir djuk

10052 mi;qZDr] dsoy LFkkiu


bLikrh rkj
10053 >yh gqbZ bLikrh rkj dh iV dh vkiwfkZ
djuk rFkk ydM+h ;k bLikr vaxksa ds lkFk
laiw.kZ LFkkiuk
10054 mi;qZDr] dsoy LFkkiuk

WIRE MATTRESSES AND SHAPED NETS

rkjh fcNkou tkyh rFkk xfBr tkfy;ka


(a)

(b)

The rates include for placing in position, binding and


joining edges, etc. with 4mm steel wire to form complete
mattresses but do not include stone, boulder or other
filling. The mattresses shall be formed by looping the
wires at each intersection.
Authorised laps shall be measured.
PER SQUARE METRE

10055 4mm dia galvanised steel wire,


150x100mm mesh, made up
into mattresses or cages, lapped,
wired and laid in position,

including closing after filling


10056 Ditto but of size 225mm x

150mm mesh ditto

Supplied &
fixed

njksa esa fLFkfr esa j[kuk] fcNkou dks iw.kZ cukus ds fy;s 4 feeh
ds bLikr rkj ls cka/kuk o fdukjksa dks tksMu+ k 'kkfey gS fdUrq
iRFkj] f'kyk[kaM ;k vU; HkjkbZ 'kkfey ugha gSA foNkou dks
mlds gj ,d dVko ij QUnk yxkdj cuk;k tk;sxkA

[k

vf/kd`r QUns ekis tk;saxsA

Except steel
wire mesh

izfr oxZ ehVj


vkiwfrZ o LFkkfir bLikr tkyh jfgr 10055 4feeh O;kl dh tLrh bLikr rkjksa dh 150
x 100 feeh tkyh dk fcNkou ;k dV?kjk
Rs.
Rs.
cukdj QUns] rk[kanh djds LFkku ij HkjkbZ
lfgr LFkkiuk
191.40
37.20
170.50

28.60

10056 mi;qZDr] fdUrq tkyh dk vkdkj 225 x 150


feeh] mi;qZDr

199

SECTION 10

SECTION 10 STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
CHAIN LINK FENCING

Ja[kyk dM+h taxys


The rate against item 10057 is for fixing only of chain link
fencing. Chain link fencing and line wire shall be paid at
'Supplied only' rates.

en 10057 dh nj dsoy Ja[` kyk dM+h Lkeku taxys dks LFkkfir djus
ds fy;s gSA Ja[kyk dM+h taxys rFkk dMh rkjksa dk **dsoy vkiwfkZ * dh
njksa ij Hkqxrku gksxkA

PER SQUARE METRE


10057 Fixing only chain link fencing including line
wires, any mesh, size and type to any type
of standards, rails, straining bolts, etc.
including provission of binding wire

Rs.

4.20

izfr oxZ ehVj


10057
10057dsoy LFkkiu] J`[a kyk dM+h taxys fdlh Hkh vkdkj o
uewus ds dM+h rkj lfgr fdlh Hkh ekud] iVjh]
dlkoh dkoys vkfn dk ca/ku rkj ds izko/kku lfgr

WIRE FENCING, ETC.

rkjksa dh ckM+ vkfn


(a) Posts and struts (of wood, concrete, steel, etc.) and straining
bolts shall be measured separately.

(b) The rates for 'add if fixed in repairs' include for dismantled wire to be neatly coiled on rough drums, (to be
supplied by M.D.) before fixing.

[k

PER 100 RUNNING


METRE
10058 Plain mild steel wire,
galvanised class 3,
in fencing including
straining and fixing
to wood, concrete or
steel posts and/or to
straining bolts,
including securing
with and provision
of galvanised iron
tying wire, galvanised
iron staples or steel
pins, etc. as directed
(each line of wire to
be measured)
10059 Ditto in detached
work such as for
mosquito nets and
fixing to straining
bolts, hooks, eyes,

etc.

Dia of wire in mm

rkj O;kl feeh esa

Except Add if Restraining


wire fixed in and resecurrkj repairs ing including
jfgr tksM+as ;fn making good
ejEer esa staples etc.

LFkkfir dqaMksa dks Bhd


djds nqckjk
yxkuk

S&F

vkiwfrZ o LFkkiuk
2.50
Rs.

343.80

3.15
Rs.

4.00
Rs.

[kaHks o LrEHk ydM+h] dahV] bLikr vkfn ds rFkk dlkoh


dCts izFkd ekis tk;saxsA
**tksM+as ;fn ejEer es*a * dh njksa esa m[kkMs+ x;s rkjksa dks yxkus
ls igys lknk Me ,e Mh }kjk fn;k tk;sxk ij lQkbZ ls
yisVuk 'kkfey gSA
izfr 100 ehVj

Rs.

493.30 739.90 94.70

Rs.

Rs.

48.40

57.60

10058 likV uje yksgs ds Js.kh 3


ds tLrh rkjksa dks lh/kk djds
funs'kkuqlkj tLrh yksgs ds
ca/ku rkj] tLrh yksgs ds dqM
a s
;k bLikrh fiuksa ls ydM+h
dahV ;k bLikr ds [kaHkksa ,oa
;k /kkjd dkoyksa ls LFkkiu
rkj dh izR;sd drkj ekih
tk;sxh

10059 mi;qZDr] vlEca/k dk;Z esa


tSl]s ePNjnkuh ds fy;s rFkk
/kkjd dkoyks]a gqdks]a vf{k vkfn
ds lkFk LFkkiu
343.80

493.30 739.90 94.70

48.40

57.60

200

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
WIRE FENCING, ETC.-Contd....

rkjksa dh ckM+ vkfn tkjh


10060 Galvanised. 2 strand, steel S&F Fixing Add if fixed Restraining
barbed wire 2.24mm dia vk- o only in repairs resecuring
barbed with 2mm dia barbs at
LFkk- dsoy tksM+s ;fn
including
75mm spacings and straining
LFkkiu
ejEer
es
a
making
good
and fixing to any type of
standard rails strain- ing
LFkkiu
staples etc.
bolts, including, securing or
dqaMksa dks Bhd
tying at crossings with and
djds nqckjk
provision of galvanised mild
yxkuk
steel wire, staples or steel
Rs.
Rs.
Rs.
Rs.
pins, etc. as directed (each
line wire to be measured) 810.00 150.00
77.10
82.90
10061 Ditto, but in wire entanglements aprons, barriers, gates,

etc.

852.30 192.20

S&F

PER KILOGRAM

vk- o
LFkk-

10062 Fixing wire entanglements and


aprons with loose, two strand,
galvanised steel barbed wire, 2.24mm
Rs.
dia barbed with 2mm dia barbs at
70.10
75mm spacings

92.60

98.20

Fixing Add if fixed


only in repairs

dsoy
LFkkiu

tksM+s ;fn
ejEer esa
LFkkfir

Rs.
7.90

Rs.
31.90

10060 tLrsnkj 2 yM+h okys bLikr ds


dkaVns kj 75 feeh vUrj ij 2-24 fe
eh O;kl ds dkaVns kj rkj rFkk mUgsa
lh/kk djds] rFkk fdlh Hkh izdkj dh
iVfj;ksa] /kkjd dkoyksa ls LFkkfir
djds lqjf{kr djuk ;k laikj.k
cka/kuk rFkk vkns'kkuqlkj tLrh uje
bLikr ds rkj] dqM
a s o bLikrh fiuksa
vkfn dk izko/kku djus lfgr laifw kZ
rkj dh izR;sd drkj ekih tk;sxh
1006
100611 mi;qDZ r] fdUrq rkjh ck/kkvksa vkoj.kks]a
jks/kdksa] QkVdksa vkfn esa

izfr fdxzk
100622 rkjca/kkbZ o vkoj.k 2-24 feeh O;kl ij 2
1006
feeh O;kl ds dkaVs lfgr dkaVns kj rkjksa dks
75 feeh vUrj ls nks yfM+;ksa esa LFkkfir
djds laiwfkZ

COLLAPSIBLE STEEL GATES

fleVokn bLikr }kj


izfr oxZ ehVj

PER SQUARE METRE


10063 Collapsible steel gates, top hung,
consisting of channel pickets, pivoted
flat bars, top and bottom runners, brass
handles etc., as specified, erected in
position and securing runners with
holdfasts and brackets, complete

S&F

Fixing only

vkiwfrZ o
LFkkiu

dsoy LFkkiu

Rs.

Rs.

2414.90

264.70

1006
100633 'kh"kZ ij fyiVs fleVokn bLikr }kj
ftlesa pSuy ?ksjs /kqjhnkj likV NMsa+ 'kh"kZ
o ry esa pdjh;ka] ihry ds gSaMy vkfn
gksa fufnZ"Vkuqlkj LFkku ij [kM+k djuk
rFkk pdfj;ksa dks gksYMQkLr o czfS dVksa ds
lkFk yxkdj laiwfk

STEEL ROLLING SHUTTERS

bLikr ds jksfyax 'kVj


The rates shall not apply if the Govt. supplies steel sheeting,
etc. to the Contractor at 'Supplied only' rates in this Schedule.

;fn ljdkj bLikrh pknjksa vkfn dh vkiwfkZ bl vuqlp


w h dh *dsoy
vkiwfkZ dh njksa ij djrh gS] rks ;g njsa ykxw ugha gksaxhA

201

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10& bLikr] yksgk rFkk vY;qfefu;e dk;Z
STEEL ROLLING SHUTTERS-Contd...
bLikr ds jksfyax 'kVj tkjh...
PER SQUARE METRE
Supplied and fixed
Fixing only any
10064 Steel rolling shutters, with out
vkiwfrZ o LFkkfir
thickness
ball bearing, as specified Thickness of laths in mm
dsoy LFkkiu
including top cover, andksbZ eksVkbZ
choring rod, hasp and staple ifV;ksa dh eksVkbZ feeh esas
1.00
1.25
and one shop coat of primer;
Rs.
Rs.
Rs.
erected in position as indicated, complete: push pull or

manual type
2212.50
2377.00
215.00
10065 Ditto, but gear operated type
with bevel gear box and crank

handle
2353.50
2682.50
215.00
10066 Ditto, but gear operated type
with chain wheel and hand

chain
2905.80
3258.30
215.00

PER SQUARE METRE


10069 Extra for wicket door
including a 4 lever mild steel
safety lock, lockable from
both inside and outside (area
of wicket door to be only

measured)

10065 mi;qZDr] fdUrq fx;j pfyu lkFk


esa Cksosy fx;M cDlk o sad gSaMy

10066 mi;qDZ r] fdUrq fx;j pkfyr fdLe


ds] lkFk esa psu ifg;k rFkk gkFk psu

iz R ;s d
10067 jksfyax 'kVj ds 4 yhoj okys uje
bLikr ds lqj{kk yhoj rkys
10068 jksfyax 'kVj ds cky fo;fjax

EACH
10067 Safety lever locks mild steel
with 4 levers for rolling

shutters
10068 Ball bearing for rolling

shutters

izfr oxZ ehVj


10064 bLikr ds jksfyax 'kVj fcuk
ckyfc;fjax ds iqy] iq'k ;k gLr
pkfyr fdLe ds fufnZ"Vkuqlkj]
'kh"kZ=k.k] fLFkj.k NM+] Nidk dqaMk
rFkk ,d is'ksoj vLrjh; ijr crk;s
vuqlkj LFkku ij LFkkfir

Rs.
463.60
414.80

izfr oxZ ehVj


10069 vfrfjDr] vUnj ckgj nksuksa vksj o
ckgj] ls cUn djus ;ksX; uje yksgs
ds 4 yhoj okys lqj{kk rkys lfgr
lqj{kk}kj dk {ks=Qy dsoy ekik
tk;sxk

1967.80

STEEL DOORS, WINDOWS AND VENTILATORS

bLikr ds njokts] f[kM++fd;ka o jks'kunku


(a) Glass or other filling in panels shall be measured
separately.
(b) The rates include for painting with one shop coat of zinc
chromate primer.
(c) The rates also apply if friction hinges are provided in lieu
of projecting hinges and peg stay.
(d) The rates for double leaf doors include for concealed bolts.
(e) The rates shall not apply if steel sections are supplied by
the Govt. to the contractor at the 'Supplied only' rates in
this schedule.

iYyksa ds 'kh'ks o vU; HkjkbZ izFkd ekih tk;sxhA

[k

,d is'ksoj tLrs ksfe;e vLrj dh ijr yxkuk njksa esa


'kkfey gSA
;fn iz{ksih dCts o [kawVh jksd ds LFkku ij ?k"kZ.k dCts
ykx;s tkrs gSa rks muij Hkh ;g njsa ykxw gksaxhA
nksgjs iYyksa ds njoktksa dh njksa esas Nqik dkoys 'kkfey gSaA

x
?k
M

;g njsa ykxw ugha gksxh ;fn bLikr [kaM ljdkj us Bsdns kj


dks **dsoy vkiwfkZ dh bl vuqlwph dh njksa ij fn;s gSaA

202

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10& bLikr] yksgk rFkk vY;qfefu;e dk;Z
STEEL DOORS, WINDOWS AND VENTILATORS-Contd...

bLikr ds njokts] f[kM++fd;ka o jks'kunku tkjh


PER SQUARE METRE

10070 Steel windows or ventilators, fixed

type, with glazing bars


10071 Steel windows with side hung
shutters including projecting type
hinges with steel handle, and steel
peg stay, complete with glazing bars,

dovetailed or welded
10072 Ditto, but without glazing bars
10073 Steel door including projecting
type hinges, steel handle, complete,
with glazing bars, dovetailed or

welded
10074 Steel ventilators with centre hung
shutter including two pairs of brass
cup pivots, catch spring and pulley

wheel, complete
10075 Steel ventilator with top hung
shutter including hinges, steel peg

stay, complete
10076 Steel windows for industrial
buildings, fixed type, with glazing

bars
10077 Steel windows for industrial
buildings with centre hung shutters
including brass pivots, catch spring

and pulley wheel complete


10078 Steel windows for industrial
buildings with bottom hung or top
hung shutters, including hinges, steel
side arms or peg stays complete
10079 Extra over steel doors, windows and
ventilators if brass handles are
provided in lieu of steel handles
10080 Ditto, if aluminium handles are
provided in lieu of steel handles
10081 Ditto, if chromium plate steel handles are provided in lieu of steel

handles

Supplied & fixed Fixing only

vkiwfrZ o LFkkiu

dsoy LFkkiu

Rs.

Rs.

1335.80

66.80

1689.40

67.90

1466.20

67.90

1884.10

86.40

1519.90

86.40

1484.60

86.40

1308.40

86.40

1437.60

86.40

1484.60

86.40
Rs.

70.50
23.50

23.50

izfr oxZ ehVj


10070 bLikr dh LFkkfir fdLe dh f[kM+fd;k]
jks'kunku] 'kh'kkxhjh dh NM+kas ds lkFk
10071 bLikr dh }kj ds lkFk yxkus okyh
f[kM+fd;ka] iz{ksih dCts o bLikr ds
gSMa y o lVhy ds [kwVa hjksd rFkk diksriqN
a h
;k >kyh gqbZ 'kh'kk yxkus dh NM+ka s lfgr
10072 mi;qZDr] fdUrq 'kh'ks dh NM+ksa jfgr
10073 bLikr ds njokts] iz{ksih fdLe ds dCts]
bLikr ds gSM
a y ds lkFk rFkk diksriwN
a h
;k >kydj 'kh'ks yxkus ds fy;s NM+sa
yxkdj laiwfk gks
10074 bLikr ds jks'kunku] chp esa yxus okys
dikV] nks tksMs+ ihry ds di/kqjh] idM+
dekuh rFkk pj[kh yxkdj laiwfkZ
10075 bLikr ds jks'kunku] 'kh"kZ ls Vaxs dikV]
dCts] bLikr ds [kwV
a hjksd yxkdj lai.w kZ
10076 bLikr dh vks|ksfxd Hkouksa ds fy, fLFkj
fdLe dh] 'kh'ks ykxus dh NM+ksa lfgr
f[kM+fd;ka
10077 bLikr dh vkS|ksfxd Hkouksa ds fy;s
f[kM+fd;ka ftuesa ihry dh /kqfj;ka idM+
dekuh o pj[kh yxkdj chp esa dikV
yxkdj laiwfk
10078 bLikr dh vkS|ksfxd Hkouksa ds fy;s 'kh"kZ
;k ry ij yxus okys dikV dh
f[kM+fd;ksa dh] dCts ik'koZ cktw ;k [kwVa h
jksd yxkdj laiwfkZ
10079 vfrfjDr] ;fn bLikrh njoktks]a f[kM+fd;ksa
o jks'kunkuksa esa bLikr ds gSaMyksa ds
LFkku ij ihry ds gSaMy yxs gksa
10080 mi;ZqDr] ;fn bLikrh gSaMyksa ds LFkku
ij vY;qfefu;e ds gSMy yxk;s gksa
10081 mi;qZDr] ;fn bLIkkrh gSaMyksa ds LFkku
ij ksfe;e ijr p<s bLikrh ds gSMy
yxk;s gksa

203

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
PRESSED STEEL DOOR FRAMES
njoktksa ds laihfM+r bLikr se
(a) The rates include for one shop coat of priming.
(b) Mild steel angle threshold shall be measured under item
10003.

d
[k

(c) The rales will not apply if the Govt. supplies steel sheeting
to the Contractor at Supplied only rates in this schedule.

(d) The sizes/dimensions and type (profile) of frames shall be


as shown in I.S.

?k

(e) Filling hollow of frame with plain cement concrete and/or


with cement mortar shall be measured and paid separately.

PER RUNNING METRE

10083 Ditto, but fixing only

seksa ds vkdkj@ifjeki vkSj uewus ik'oZ fp= tSls fd Hkkek- esa n'kkZ;s x;s gSaA
seksa dks lkns lhesaV dahV vkSj@;k lhesaV xkjs ds lkFk
fu%lkj HkjkbZ i`Fkd ekih ,oa ns; gksxhA

iz f r ehVj
105 x 60mm 125 x 60mm 165 x 60mm 10082 njoktksa ds fy;s laihfMr bLikr
105 x 60 feeh 125 x 60 feeh 165 x 60 feeh
ds ,d ;k vf/kd i[kksa okys se]
fufnZ"Vkuqlkj vko';d fLFkj
Rs.
Rs.
Rs.
idM+] dCts] rkys dh IysV vkfn

yxs lfgr dh vkiwfkZ o LFkkiuk


250.30
285.60
326.70
21.20
21.20
21.20
10083 mi;qZDr] fdUrq dsoy LFkkiu
Size of frame

10082 Pressed steel frames for doors


with one or more rebates
including necessary fixing
lugs, hinges, lock strike plate,
etc., complete, as specified,

supplied and fixed

njksa ,d is'ksoj vLrjh; ijr 'kkfey gSA


uje bLIkkr ds nksgjh lfj;s en 10003 ds vUrxZr ekis
tk;sx
a As
;g njsa ykxw ugha gksaxh ;fn ljdkj us Bsdsnkj dks] bl
vuqlwph dh **dsoy vkiwfkZ** nj ij bLikr pknj nh gSaA

se dk vkdkj

WELDING IN REPAIRS
ejEerksa esa >ky Vkadk yxkus ds dk;Z
(a) The rates include for cleaning and preparing the surfaces
to be welded together, holding the members in true position
while welding and bevelling of edges, as required, in the
case of metal exc 3mm thick.
(b) Taking down the article and refixing in position after
welding shall be measured separately.

[k oLrqvksa dks fudkyuk rFkk Vkadk yxkus ds ckn muds LFkku ij


yxkus ds dk;Z dks izFkd ekik tk;sxkA
izfr 10 lsaVhehVj

Thickness of metal to be welded

PER 10 RUNNING
CENTIMETRES

Vkadk yxk;s tkus okys /kkrq dh eksVkbZ


N exc 6mm

vuf/kd 6 feeh

10084 Running welding

in repairs

d bu njksa esa ftl LFkku ij Vkadk yxkuk gS mls lkQ djuk o


laokjuk] Vkadk yxkrs le; vaxksa dks fLFkj idM+uk] 3 feeh ls
vf/kd eksVkbZ dh /kkrq ds ekeys esa visf{kr i[k cukukA

Exc 6 mm but Exc 9 mm but Exc 20mm but


n exc 9mm
n exc 20mm n exc 25mm

vf/kd 6 feeh
ijarq o 9 feeh
ls vuf/kd

vf/kd 9 feeh
ijUrq 20 feeh
ls vuf/kd

vf/kd 20 feeh
ijUrq 25 feeh
ls vuf/kd

Rs.

Rs.

Rs.

Rs.

14.40

25.20

49.50

62.20

10084 ejEer esa Hkhrjh >ykbZ

204

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
WELDING IN REPARIS Contd...
ejEerksa >ky Vkadk yxkus ds dk;Z tkjh
Thickness of Metal to be welded

Vkadk yxk;s tkus okys /kkrqdh eksVkbZ


EACH

N.exc.
6mm

Exc. 6mm but Exc. 9mm but Exc. 20mm but


n.exc 9mm
n.exc 20mm
n.exc 25mm

vuf/kd 6 vf/kd 6 feeh


feeh
ijUrq 9 feeh
ls vuf/kd

vf/kd 9 feeh
ijUrq 20 feeh
ls vuf/kd

vf/kd 20 feeh
ijUrq 25 feeh
ls vuf/kd

10085 Welding in repairs


n. exc 2.5cm in

length

Rs.

Rs.

Rs.

Rs.

2.90

3.00

8.30

13.40

10086 Ditto, exc 2.5cm


but n exc 5cm in

length

3.80

6.60

11.00

15.40

iz R ;s d

10085 ejEerksa esa 2-5 lseh


yEckbZ ls vuf/kd dh
>ykbZ
10086 mi;qZDr] yEckbZ 2-5
lseh ls vf/kd fdUrq 5
lseh ls vuf/kd

ANODISED ALUMINIUM FRAMES FOR DOORS, WINDOWS AND VENTILATORS


njoktksa] f[kM+fd;ksa rFkk jks'kunkuksa ds ,uksMhd`r vY;qfefu;e pkS[kVs

d ihchlh jf{kr pknjhdj.k O;oLFkk rFkk pkS[kVk LFkkfir djus ds


ckn mls gVkuk 'kkfey gSA
(b) Weight of joining cleat shall be added to main frame.
[k tqM+kbZ xV~Vksa ds Hkkj dks eq[; pkS[kVs esa tksM+k tk;sxkA
(c) Hinges, shutters and lugs shall be measured and paid for x dCts] dikV o idM+ksa dks izFkd ekik o Hkqxrku gksxkA
(a) The rates include for provision of PVC protected sheeting
and its removal after fixing the frame work.

separately.
PER KILOGRAM
10087Anodised aluminium frame for doors,
windows, ventilators with one or more
rebates including joining cleat for
fixing etc. complete all as specified
10088Add Extra for Powder Coating to Item
No. 10087 above to (minimum
thickness of powder coating 50

micron)

S&F

Fixing only

vk- o LFkk-

dsoy LFkkiuk

Rs.

Rs.

233.50

51.40

16.00

iz f r fdyks x z k e
10087 ,uksfMd`r vY;qfefu;e pkS[kVs] njoktksa f[kM+fd;ksa
o jks'kunkuksa ds fy;s] ,d ;k nks iSrkHkh tqMk+ bZ
xV~Vksa vkfn lfgr fufnZ"Vkuqlkj laifw kZ

ANODISED ALUMINIUM SHUTTERS FOR DOORS, WINDOWS AND VENTILATORS


njoktksa] f[kM+dh ds fy;s] ,uksMhd`r vY;qfefu;e dikV
(a) Glass and other filling material in panels shall be measured d iYyksa esa 'kh'ks o vU; HkjkbZ izFkd ekih o HkqxrkbZ tk;sxhA
and paid for separately.
(b) Area of opening shall be measured to the nearest 0.5 sq.cm.
(c) The rates does not include for anodised aluminium hard
wares as indicated, glazing clips, rubber packing, anodised
aluminium snap on beading for fixing glass panes in
frames.

[k [kqys LFkkuksa dks fudVre 0-5 olseh rd ekih tk;sxhA

x njksa esa crk;s vuqlkj ,uksMhd`r vY;qfefu;e ds e'khuh miknku]


'kkh'ksnkjh dh fpefV;ka] jcM+ dh HkjkbZ] ,uksMhd`r vY;qfefu;e ds
'kh'ks Qyd se esa yxh xksVu ij yxkus ds fy;s 'kkfey ugh gSAa
(d) Fixing of shutters with fittings shall be as per ?k dikVksa dk miLdjksa ds lkFk LFkkiu fuekZrk ds funsZ'kkuqlkj
manufacturers instructions.
fd;k tk;sxkA

205

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
ANODISED ALUMINIUM SHUTTERS FOR DOORS, WINDOWS AND VENTILATORS-Contd...
njoktksa] f[kM+dh ds fy;s] ,uksMhd`r vY;qfefu;e dikV tkjh
PER SQUARE METRE
10089 Anodised aluminium door shutters,
aluminium section weighing 0.55 kg/
m including necessary joining cleats,
glazing clips, ruber neoprene packing,
handles 2 Nos in each door, hinges,
anodised aluminum snap beading

screws etc. complete all as specified.


10090 Anodised aluminium window and
ventilator shutters, fixed type
without sash bar, aluminium section
weighing 0.55 kg/m including
necessary joining cleats, glazing
clips, rubber packing, anodised
aluminium snap beading, screws

etc. complete all as specified


10091 Anodised aluminium window and
ventilator shutters, side hung type
without sash bars, aluminium sections
weighing 0.55 kg/m including
necessary joining cleats, glazing clips,
rubber packing, anodised aluminium
snap beading, screws, anodised
aluminium fittings such as peg stays
150mm long (1 no.). hinges type B-21
100mm long (2 no.) suitable handle (1

no.) complete all as specified


10092 Add to item No 10089 to 10091 for
powder coating of any colour
(Thickness or powder coating not

less than 50 micron).

S&F

Fixing only

vk- o LFkk-

dsoy LFkkiu

Rs.

Rs.

izfr oxZ ehVj


10089

629.80

95.90

617.20

110.40

649.50

110.40

30.80

10090 ,uksMhd`r vY;qfefu;e ds LFkkfir fdLe ds


f[kM+dh] jks'kunku ds dikV] la/kkj iV~Vh
jfgr] 0-55 fd-xzk-@eh Hkkfjr vY;qfefu;e
lfj;s] vko';d tqM+kbZ xV~Vs] 'kh'ksnkjh dh
fpefV;ka] jcM+ HkjkbZ] ,uksMhd`r vY;qfefu;e
LuSi xksVu] isp vkfn fufnZ"Vkuqlkj laiw.kZ

10091 ,uksMhd`r vY;qfefu;e ds ik'oZ yfEcr fdLe


ds la/kkj iV~Vh jfgr] 0-55 fdxzk@eh Hkkfjr
vY;qfefu;e lfj;s vko';d tqM+kbZ xV~Vs
'kh'ksnkjh dh fpefV;ka] jcM+ HkjkbZ] ,uksMhd`r
vY;qfefu;e LuSi xksVu isp] ,uksMhd`r
vY;qfefu;e miLdj tSls 150 feeh yEcs
1 ua- vkMh [kaVw h ch&21 fdLEk ds 100 feeh
yEcs dCts 2 ua- mi;qDr ewB 1 ua- lc
fufnZ"Vkuqlkj lai.w kZ
10092

ANODISED ALUMINIUM FRAME WORK (SANP GRID) FOR FALSE CEILING


cukoVh v/k% gsrq ,uksMhd`r vY;qfefu;e Qjescanh LuSi tky
(a) The rates include for provision of PVC protected sheeting
and its removal after fabrication.

(b) The work shall be measured and paid for net finished work
of grid frame.

[k

(c) The rates shall also include for necessary notching and
prepared holes.
(d) The rates do not include for supporting hanger comprising
of mild steel rod, J bolt with necessary washers, bolts and
nuts, for securing frame work to ceiling and to the snap grid.

(e) The supporting hanger comprising of mild steel rod, bolts


with necessary bolts, nuts and washers shall be measured
and paid for separately.

?k

njksa esa ihchlh j{k.k pknjhdj.k O;oLFkk djuk rFkk lajpuk


ds ckn mls gVkuk 'kkfey gSA
dk;Z dh eki o Hkqxrku >a>jh se ds laifw kZ dk;Z dh fo'kq)
gksxhA
njksa esa vko';d [kkapsnkjh rFkk Nsn lajpuk 'kkfey gSA
njksa esa lgk;d vkyEcu] ftlesa uje yksgs ds lfj;s]
vko';d ok'kj lfgr ts dkoys] Qjesnkjh o LuSi tky dks
Nr esa lqjf{kr djus ds fy;s dkoys o f<ofj;ka 'kkfey gSaA
lgk;d vkyEcu ftles]a uje yksgs ds vko';d dkoys o
f<ofj;ka o ok'kj ds lkFk ts dkoys] izFkd ekis tk;sxa s o ns; gksxa As

206

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
ANODISED ALUMINIUM FRAME WORK (SANP GRID) FOR FALSE CEILING Contd...
cukoVh v/k% gsrq ,uksMhd`r vY;qfefu;e Qjescanh LuSi tky tkjh
PER SQUARE METRE

10093

10094

10095

Anodised aluminium snap grid


frame work for false ceiling all

as specified
Gl frame work for seamless
ceiling comprising of Gl
perimeter channnel 0.55 mm
thick with two unequal flanges
of 20 and 30 mm and web of
27 mm fixed to surrounding
wall using nylon sleeves and
screws at 450 mm centre to
centre/intermediate channel
0.9 mm thick having two equal
flanges of 15 mm each and web
of 45 mm suspended from
soffit at approx 900 mm centre
to centre with Gl cleat and
steel expansion fasteners with
and including ceiling section
(not exc 1.2 m length) of 0.55
mm thickness having kurled
web of 50 mm and flange of
26 mm each with lips of 10.5
mm fixed to the intermediate
channel with connecting clips
across the intermediate
channel at 457 mm centre to

centre.
Hangers 6 mm dia. G.I. (upto
1200mm length) adjusting level
fixed to roof slabs by means of
ceilling cleats made out of G.I.
flat 40 x 3 mm size 60mm long
and expansion hold fasteners
12.5mm dia. 40mm long

complete all as specified

Size of grid 605 x 605mm


tky vkdkj 605 x 605 feeh
S&F

Fixing only

vk- o LFkk-

dsoy LFkkiu

Rs.

Rs.

261.90

53.30

237.30

71.70

izfr oxZ ehVj

10093 ,uksMhd`r vY;qfefu;e dk cukoVh Nr esa


lc fufnZ"Vkuqlkj tky Qjescanh

207

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
ANODISED ALUMINIUM FRAME WORK (SANP GRID) FOR FALSE CEILING Contd...
cukoVh v/k% gsrq ,uksMhd`r vY;qfefu;e Qjescanh LuSi tky tkjh
LABOUR ONLY ON IRON AND STEEL WORK
bLikr rFkk yksgs dk;Z ij dsoy Je

(b) Any rolled sections on which drilling or notching is allowed


under the following items, shall be measured under the
items for plain sections and not under the items for builtup work.
(c) The rates below shall be doubled when the work is required
to be done in position.

d en 10096 ls 10105 dh njsa rHkh ykxw gksxh tc ekfir dk;Z


dh njksa esa 'kkfey ugha gksxk rFkk igys ls gh izFkd dk;Z ds :i
esa fo'ks"k :Ik vknsf'kr gksxkA
[k fdlh izdkj ds jksYM csfYyr [kaMksa ij tgka ojesa dk dk;Z ;k
[kkapsnkjh bu njksa esa ykxw gS og likV [kaMksa ds varxZr ekis
tk;saxs uk fd fufeZr dk;Z dh njksa ds varxrZA
zx uhps dh njksa dks nqxquk dj fn;k tk;sxk ;fn dk;Z dk laiknu
LoLFkku esa visf{kr gSA

DRILLING AND TAPPING

HkjkbZ Nsn o pwM+h dVkbZ

(a) The rates for items 10096 to 10105 shall apply only when
not included in the items for measured work and are
specially ordered before-hand as a separate job.

PER 10 NOS.

Depth of hole in mm

izfr 10 ux

fNnz xgjkbZ feeh esa


Exc 3 but n Exc 12 but n
exc 12
exc 25
10096 Holes drilled up to 12mm dia
(and countersunk, if

required)

vf/kd 3 o
vuf/kd 12

vf/kd 12 o
vuf/kd 25

Rs.

Rs.

40.30

92.60

10097 Ditto, but dia of holes


drilled exc 12mm and n exc.

25mm (ditto)

64.80

150.50

10098 Ditto, but dia of holes


drilled exc. 25mm and n exc.

40mm dia (ditto)

106.50

231.50

10099 Add to items10096 to 10098


if tapped in addition (with
standard or gas thread, as

directed)

100%

100%

Exc 25 but n
exc 40

vf/kd 25 o
vuf/kd 40 10096 ojes ls fd;s x;s 12 feeh O;kl
rd ds Nsn rFkk ;fn t:jr gks
Rs.
rks izR;kjksi.k
138.90
10097 mi;ZDq r] fdUrq Nsn 12 feeh O;kl
231.50
ls vf/kd rFkk 25 feeh O;kl ls
vuf/kd mi;ZqDr
10098 mi;ZDq r] fdUrq fNnz O;kl 25 feeh
370.40
ls vf/kd o 40 feeh O;kl ls
vuf/kd mi;ZDq r
10099 tksM]+as en 10096 ls 10098 esa ;fn
100%
vfrfjDr pwMh+ gksa ekud ;k xSl
pwMh+ ds lkFk] tSlk funsfZ 'kr

208

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
LABOUR ONLY ON IRON AND STEEL WORK-Contd...
bLikr rFkk yksgs dk;Z ij dsoy Je tkjh
PUNCHING SMALL HOLES
NksVs Nsn fudkyuk
izfr 10 la[;k
10100 yksgs ;k uje bLikr esa gkFk ls] dhyksa ;k ispksa
ds fy;s Nsn fudkyuk 0-63 ls 1-60 feeh
eksVkbZ
10101 mi;qZDr] fjfiV ;k dkoyksa ds fy;s yksgs ;k
uje bLikr esa 6 feeh vuf/kd eksVs Nsn
fudkyuk
10102 tksMsa+ vafre esa ;fn Nsnksa dks c<+kuk gS

PER 10 NOS.
Rs.

10100 Holes for nails or screws, hand


punched through iron or mild steel

(0.63 to 1.60mm thickness)

4.50

10101 Ditto for rivets or bolts through iron


or mild steel not exceeding 6mm

thick

28.40

10102 Add to last if holes are reamered

9.00

CUTTING OR NOTCHING ON IRON AND STEEL WORK


yksgs ,oa bLikr ij dVkbZ ;k [kkpsnkjh dk;Z
The rates include rough filing. In measuring cuts on rolled
steel joists, the web shall be measured separately and the
average thickness of the flanges shall be taken.
PER RUNNING METRE (OF CUT)

njksa esa eksVh HkjkbZ 'kkfey gSA yisVoka dfM+;ksa dh dkVksa dh eki esa
f>Yyh izFkd ekih tk;sxh rFkk fdukjksa dh vkSlr eksVkbZ yh tk;sxhA
izfr ehVj dkV dk

Width of cut

dkV dh pkSM+kbZ
Upto 10

mm
10 feeh rd
10103Straight, raking or circular cutting
on iron or steel, as in straight or
splay cuts, notches, rounded angles,
etc. (length or girth of cutting ex
ceeding 75mm)

Exc 10 mm but
n exc 20mm

10ls vf/kd o
20feeh ls
vuf/kd

Rs.

Rs.

139.90

275.20

10103 yksgs ;k bLikr ij lh/kh] [kkapns kj] ;k xksykdkj


dVkbZ tSlh lh/kh ;k frjNh dVkbZ [kkapns kj ;k
xksykdkj lfj;ksa vkfn esa gksrh gSA
iz R ;s d

EACH
10104All as per item 10103, but length or
girth of cutting n exc 75mm

13.50

27.10

10104 lc en 10103 tSlk] fdUrq dVkbZ dh yEckbZ


;k ?ksjk 75 feeh ls vf/kd ugha

REPAIRS TO GRATES, RANGES, ETC.


>a>jh o pwYgksa dh ejEer
PER 10 NOS.
10105 Fitting in repairs, any of the following parts of
grates, ranges, etc. supplied by M.D. including
drilling out old bolts or set screws, as required,
set of front bars; bottom grating; pairs of iron
fire cheeks; outer door; furnace door; sets of
bulls eyes with seatings; damper rods; soot
doors; smoke boxes; register plates; falling
doors; and any other standard component of
grates or ranges used for cooking

Rs.

636.30

izfr 10 la[;k
10105 >a>jh o pwYgksa dh ejEer esa ,e Mh }kjk fn;s x;s fdlh
Hkh fUkEu vax dk iqjkus dkoys ;k yxs gq;s isp ckgj
fudkyus lfgr LFkkiu@iz"B lfj;k lewg] ry tkyh]
YkkSg vaxhBh Qyd tksMk+ ] ckgjh }kj] fcBkos lfgr
xok{k lewg] voeand NM+]as dTty }kj] /kqvk isVh
ljdu IysV] ikrh }kj rFkk vU; dksbZ ekud va'k
tks [kkuk cukus es]a >a>jh ;k pwYgs esa dke vkrs gSa

209

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
MATERIALS (SUPPLIED ONLY)
lkexzh dsoy vkiwfrZ
PER KILOGRAM

izfr fdyksxzke
10106 <yk yksgk] Js.kh ,Q th 150 <ykbZ dk;Z ds
mi;qDr

Rs.

10106 Cast iron, grade FG 150 suitable for casting


49.60

Fe-290
(Gde E165)

Fe 410-W
(Gde-E250) quality-A

PER KILOGRAM

Fe-410W(Gde- E250) qualityB

10107 Mild steel in flat, round or square


bars, in available lengths

Rs.

Rs.

Rs.

42.30

41.10

42.30

10108 Structural steel, rolled section such


as joist, beam, channel, angle, tee,

in available lengths

42.30

41.10

43.40

10109 Mild steel plates, plain or


chequered, 5mm thick or over in

thickness in available sizes

48.20

49.30

49.30

PER KILOGRAM

Mild steel round bars

izfr fdyksxzke
10107 uje bLikr dh xksy piVh lfj;k]
miyC/k yEckbZ dh
10108 bekjrh bLikr] fyiVoka [kaM tSls fd
dM+h] /kju] iz.kky] dks.k Vh] miyC/k
yEckbZ esa
10109 uje bLikr dh IysV]as lery ;k [kkapns kj]
5 feeh eksVh ;k vf/kd miyC/k vkdkj esa

Deformed or
twisted steel
bars

uje bLikr xksy lfj;k

TMT
bars

izfr fdyksxzke

vxf<+r ;k fo:i.k
bLikr lfj;k
Fe 410-W Fe-290
(Gde-E(Gde E250) qua- 165)
lity-A

10110 Bars for reinforcement, in Rs.

available lengths
40.50

Rs.
40.50

1S-432
Gde I
Rs.
40.50

Rs.
40.50

Rs.
41.10

10110 izcyu ds fy;s] miyC/k


yEckbZ ds lfj;s

izfr fdyksxzke

PER KILOGRAM

Rs.

10111 Plain or corrugated steel sheets, any


thickness in available sizes, black

47.00

10112 Ditto but galvanised class 3

50.50

10113 Ditto but galvanised with grade of Zink


coating 350.

54.00

10111 lery ;k iukjhnkj bLikrh pknjsa] miyC/k


vkdkj esa fdlh Hkh eksVkbZ dh] dkyh
10112 mi;qZDr] fdUrq tLRknkj Js.kh 3
10113

PER KILOGRAM

Diameter in mm

izfr fdyksxzke

O;kl feeh esa


10114 Mild steel soft drawn binding or tying wire,
annealed

0.90

1.00

Rs.

Rs.

56.40

56.40

10114 uje bLikr ds cus cka/kus ;k dlus ds rkj


rkfir

210

SECTION 10

SECTION 10STEEL, ALUMINIUM AND IRON WORK


[k.M 10&bLikr] yksgk rFkk vY;qfefu;e dk;Z
MATERIALS (SUPPLIED ONLY) Contd....
lkexzh dsoy vkiwfrZ tkjh....
PER KILOGRAM

izfr fdyksxzke

Diameter in mm

O;kl feeh esa


0.90

1.25

1.60

2.00

2.50

3.15

4.00

Rs.
Rs.
Rs.
10115 Galvanised mild steel
63.40 62.30 61.10
plain wire

Rs.

Rs.

Rs.

Rs.

Weight per square metre

PER KILOGRAM

10115 tLrh uje bLikr ds lkns rkj

60.10 62.30 62.30 62.30

izfr fdyksxzke

Hkkj izfr oxZ ehVj


Not exc

Exc 4 kg

4 kg
4 fdxzk- ls
vuf/kd
Rs.
10116 Expanded metal in available size

4 fdxzk- ls
vf/kd
Rs.

52.90

51.70

10117 Hard drawn steel wire fabric in

available size

52.90

51.70

10118 Welded steel wire fabric

54.00

52.90

10116 foLrfjr /kkrq miyC/k vkdkj esa


10117 dBksj xfBr bLikr rkj ifj/kku miyC/k vkdkj esa
10118 Vkafdr bLikr rkj ifj/kku

Rs.
10119 Chain link MS galvanisd fencing, any

size or type

67.00

10120 Barbed wire, galvanised, 2 strand,

2.00mm dia barbed at 75mm spacing

64.60

10121 ERW or Induction butt weld M.S. tube


black conforming to IS 1161-1979

grade Yst 240

63.50

10119 yM+h dM+h uje bLIkkr tLrhnkj ?ksjkcanh fdlh


vkdkj ;k vkd`fr esa
10120 dkaVsnkj rkj tLrh] 2 dkaVs 2-00 fefe O;kl 75
feeh vUrj ij
10121 ERW ;k varjh; VDdj Vkafdr uje yksgs dh
uyh dkyh Hkkek 1161 1979 Js.kh Yst 240 ds
vuq:Ik

211

SECTION 11

SECTION 11ROOF COVERING


[k.M 11&Nr vkPNknu
SPECIAL CONDITIONS
foksk krsZ
11-1 eki
11-1-1 lHkh dk;Z tSls fLFkj gSa fcuk mHkkj vkfn ds fo'kq) ekis
tk;saxs flok; buds%&
(a) Openings upto 0.4 sq.m. shall not be deducted.
d 0-4 oeh rd ds foCkjksa dh dVkSrh ugha gksxhA
(b) Portions of roof covering overlapped by ridge or
[k Nr vkPNknu ds] ihB ;k iqVBksa ds dkj.k vk;s mHkkjksa
hip coverings shall be included in the
dks Nr vkPNknu dh eki esa tksM+k tk;sxkA

11.1 Measurements
11.1.1 All work shall be measured net as fixed without any
allowance for laps, etc., except that :

measurements of roof covering.


11.1.2 Openings or recesses involving cutting (straight,
raking or circular) not exceeding 1 metre girth shall
be classified as holes or notches and shall be
measured separately.
11.1.3 Openings exceeding 0.4 sq.m. shall be deducted,
nothing extra shall be paid for making such openings when a square cut extends the full length or
width of a sheet.
11.2 Rates
11.2.1 Galvanised Steel Sheets, Plain or Corrugated
(a) The 'except sheeting', 'fixing', 'add in repairs', etc.,
rates for black sheetings, shall equally apply to
galvanised sheeting of any class.
(b) Where it is not feasible to ascertain the class of
galvanised sheets such as in the case of old sheets,
payment shall be allowed as for class 3 galvanised
sheets.
11.2.2 Work in Patches
(a) The term 'large patches' shall be applicable when
repairs to a roof in one or more patches (total area
of all patches taken together) in one side of the roof
is more than 25 percent of the total area of that side
of the roof.
(b) The term "small patches' shall be applicable when
repairs to a roof in one or more patches (total area
of all patches taken together) in one side of the roof
is 25 (or less) percent of the total area of that side of
the roof.
(c) The expression 'one side of the roof' means an area
extending from one gable wall to another, from a
gable wall to a hip or valley, between two hips or
two valleys, or between a hip and a valley in length
and from eaves to ridges in breadth. Such 'side of
roof' includes any subsidiary roof features such
as roofs to dormers, turrets, etc., which may be
contained within any areas as defined above.

11-1-2 fcoj ;k f>fj;ka dVkbZ ls lacfU/kr lh/kh] [kkapsnkj ;k


xksykdkj 1 ehVj ls vuf/kd ?ksjs okyh dks Nsn ;k [kkaps ds
:Ik esa oxhZd`r fd;k tk;sxk rFkk izFkd ekis tk;saxsA
11-1-3 0-4 oeh ls vf/kd ds fcoj ?kVk;s tk;saxs] ,sls fcoj cukus
ds fy;s dqN Hkh vfrfjDr ns; ugha gksxk tc ,d pkSdksj
dkV pknj dh iwjh yEckbZ ;k pkSM+kbZ rd gksA
11-2 njs a
11-2-1 tLrh yksgs dh pknjsa] lknh ;k iukjhnkj
d **pknj jfgr** **LFkkiu** tksM+as ;fn ejEer es*a * vkfn
dh dkyh pknjhdj.k dh njsa leku:i ls fdlh Hkh
Js.kh dh tLrsnkj pknjhdj.k ij ykxw gksaxhA
[k tgka tkyh pknjksa dh Js.kh dk vuqeku yxkuk laHko
ugha gS tSls iqjkuh pknjksa vkfn ds ekeyksa esa ogka
Hkqxrku Js.kh 3 dh tLrh pknjksa leku Lohd`r gksxkA
11-2-2 isouksa esa dk;Z
d *cM+s isou* dh vfHkO;fDr ogka ykxw gksx
a h tgka ,d Nr
dh ejEer] ,d ;k vf/kd isouksa esa lHkh isouksa dk
dqy {ks=Qy fy;k tk;sxk Nr dh ,d rjQ dk
{ks=Qy ml rjQ dh Nr ds dqy {ks=Qy ds
25 izfr'kr ls vf/kd gSA
[k *NksVs isou* dh vfHkO;fDr ogka ykxw gksxh tc ,d Nr
dh ejEer esa ,d ;k vf/kd isouksa lHkh isouksa dk
dqy {ks=Qy fy;k tk;sxk dk Nr ds ,d vksj ml
vksj dh Nr ds dqy {ks=Qy dk 25 izfr'kr ;k de
gSA
x *Nr ds ,d vksj* 'kCnka'k dk vFkZ gS Nr nhokj ds ,d
ik[ks ls nwljs ik[ks rd] ,d nhokj ik[ks ls iqVBs ;k
/kkjh rd] nks iqVBs ;k nks /kkfj;ksa ds chp ;k ,d iqVBs
o /kkjh ds chp dh yEckbZ rFkk vksyh ls pksVh rd
pkSMk+ bZ esa ,slh *Nr ik'oZ* esa lgk;d Nr vkdkj tSls
fd <ykuksa daxjw ksa vkfn dh Nrsa tks fd fdlh Hkh +ij
ds of.kZr {ks= esa vkrs gSa] 'kkfey gSaA

212

SECTION 11

SECTION 11ROOF COVERING


[k.M 11&Nr vkPNknu
SPECIAL CONDITIONS-Contd...
foksk krsZ tkjh
(d) Work in patches 'large' or 'small' shall be paid for
at the appropriate rates for new work in this
Section and for taking down under Section 21Demolition and Dismantling with the following
additions. These shall cover all additional labour
etc., in repairing patches including bonding to
existing work.
(i) For large patches.
10 percent on 'dismantling' and 'fixing only' or
'except principal materials' rates, i.e. 'except sheets',
etc., rates.
(ii) For small patches.
25 percent on ditto.
(iii) Principal materials required to make good
deficiencies (if to be supplied by the Contractor)
shall be paid for at 'supplied only' rates.

?k *cM+s* ;k *NksVs* isou dk;ksZ dk bl [kaM ds u;s dk;Z


dh njksa ds vUrxZr Hkqxrku gksxk rFkk m[kkM+us dk
[kaM 21 rksM+ fxjkuk o m[kkM+uk esa bu la;kstuksa
lfgrA blesa lHkh vfrfjDr Je isou dh ejEer]
ekStwnk dk;Z ds feyku lfgr 'kkfey djrh gS%&

cMs+ isouksa fd fy;sA


*m[kkM+uk* o *dsoy LFkkiuk* ;k *eq[; lkexzh
jfgr* dh njksa ij 10 izfr'kr vFkkZr *pknj
jfgr^ vkfn njsaA
(ii) NksVs isouksa ds fy;sA
mi;qZDr ij 25 izfr'krA
(iii) dfe;ksa dks Bhd djus ds fy;s visf{kr izeq[k
lkexzh ;fn vkiwfk Bsdsnkj }kjk dk Hkqxrku
*dsoy vkiwfk* dh njksa ij gksxkA
(i)

PLAIN OR CORRUGATED STEEL OR ASBESTOS CEMENT SHEETING IN ROOFS, CHAJJAS, SUNSHADES,


CLOAKING TO WALLS AND PARTITIONS, COVERING TO DOORS, ETC.

lery ;k iukjhnkj bLikr ;k ,LoSLVl lhesaV pknjhdj.k] Nrksa NTtksa] /kwiNknuksa] nhokj vkoj.kksa rFkk foHkktuksa]
}kj vkoj.kksa esa
(a) The net area of sheeting, as fixed, shall be measured on the
flat (not girthed to corrugations) without any extra allowance
for laps which are included in the rates.
(b) Ridges and hips shall be measured along the centre line.
(c) The rates include for fixing, etc., complete; for all straight
cutting (and waste) extending the full width or length of a
sheet and mitring at corners.
(d) The rates for 'except sheeting' and 'Labour only' apply to
both new and old sheets.
(e) No adjustment to the rates shall be made if no side or end
laps are required due to the fixing of a single sheet or fixing
of a number of sheets sidewise or endwise.
(f) No deduction shall be made for holes cut for roof extractors.

d yxh gqbZ pknjksa dk {ks=Qy likV iukjhnkj ?ksj ugha fcuk


mHkkjksa dks tksM+s tks fd njksa esa 'kkfey gS] fo'kq) ekik tk;sxkA
[k p<+kos@mBko rFkk iqVBs dsfUnz; js[kk ds lkFk ekis tk;saxsA
x njksa esa LFkkiu lfgr laiwfkZ] lHkh lh/kh dVkbZ rFkk Nhtu
pknj dh iwjh yEckbZ ;k pkSMk+ bZ rd rFkk fdukjksa ij uksd lfgr
'kkfey gSA
?k ^pknj jfgr* o *dsoy Je* dh njsa ubZ vksj iqjkuh nksuksa izdkj
dh pknjh dk;Z ij ykxw gksrh gSaA
M njksa ij dksbZ lek;kstu ugha gksxk ;fn bdgjh pknj ;k vusd
pknjksa dks frjNk ;k lh/kk yxkus ds fy;s] cxyh ;k fdukjh
mHkkjksa dh t:jr ugha gSA
p Nr fu"d"kZu gsrq dkVs x;s Nsnksa dh dksbZ dVkSrh ugha gksxhA

213

SECTION 11

SECTION 11ROOF COVERING


[k.M 11&Nr vkPNknu
CORRUGATED STEEL SHEETING
bLikr dh iukjhnkj pknj yxkbZ
PER SQUARE METRE

S&F

Except
Labour
vkiwfrZ o LFkkiuk sheeting only (any
Thickness in mm (any thick- thickness)
eksVkbZ feeh esa
ness)
dsoy Je

11001 Black, corrugated mild steel


sheeting with two corrugations
0.63
0.80
side lap, fixed with coach
Rs.
Rs.
screws and washers, in roofs,
341.00 414.50
walls etc.
11002 Galvanised, corrugated
mild steel sheeting with two
corrugations
side lap,
fixed with coach screws
and washers, in roofs, walls
etc. with grade of zinc
392.20 457.90
coating 275.
11003 Add to items 11001 & 11002 if
fixed with L-type or J-type or
cranked hook bolts in lieu of

screws
11004 Add to items 11001 & 11002
if bent to a curve (of any

radius)

izfr oxZ ehVj

pknj jfgr dksbZ eksVkbZ 11001 uje yksgs dh dkyh ygfj;k pknj
nks oxyh p<+ko ygj ds lkFk]
dksbZ eksVkbZ
dksp ispksa o ok'kjksa ls Nrks]a nhokjksa
Rs.
Rs.
vkfn esa LFkkfir
37.40
34.40
11002 tLrsnkj uje yksgs dh ygfj;k
pknj nks cxyh p<+ko ygj ds
lkFk] dksp ispksa o ok'kjksa ls LFkkfir
Nrksa] nhokjksa vkfn esa fuEu Js.kh
dh
37.40

34.40

11003 tksM+sa en 11001 vkSj 11002 esa


;fn ispksa ds LFkku ij gqd] ;k
vjky dkoyksa ls LFkkfir gksa
13.20

33.60

PER RUNNING METRE

11005 Add to mild steel sheeting, any thickness, if the side laps are riveted or

bolted at 20cm centre to centre


11006 Ditto, if the end laps are riveted or

bolted at each corrugation

13.20

36.10

13.20

8.50

34.90

M&L

Labour only

lkexzh ,oa
Je

dsoy Je

Rs.

Rs.

15.80

12.70

42.70

38.20

11004 tksM]+as en 11001 vkSj 11002 esa


;fn o ij eqMh+ gksa dksbZ f=T;k

iz f r ehVj

11005 tksMas+ fdlh Hkh eksVkbZ dh bLikr pknjksa


ds dk;Z ij ;fn cxyh p<+kos dyeh
gSa ;k dkoys 20 lseh ds vUrj yxh gks
11006 mi;qDZ r] ;fn vk[kjh p<+kos dyeh gSa
;k gj ygj ij dkoys yxs gSa

214

SECTION 11

SECTION 11ROOF COVERING


[k.M 11&Nr vkPNknu
CORRUGATED ALUMINIUM SHEETING
ygfj;k vY;q f efu;e pknjh dk;Z
PER SQUARE METRE

izfr oxZ ehVj

S&F

Except
Labour
vkiwfrZ o LFkkiuk sheeting only (any
(any thick- thickness)
Thickness in mm
ness)
dsoy Je

11007 Aluminium corrugated


sheeting Alloy 31000 H4,
STUCCO Embossed finish
with two corrugations side
eksVkbZ feeh esa
lap fixed with coach
0.71
screw and Aluminium 0.56
washer in roof and wall Rs.
Rs.
etc. with end laps stitched
with 25x6mm G.I. bolts at 357.60
441.60

20cm apart
11008 Add to item 11007 if fixed
with L-type or J-type or
cranked hook bolts in lieu
13.20
13.20
of screw

11007 mHkjh uDdk'khnkj feJ/kkrq 31000


,p&4] STUCCO vY;feqfu;e
ifj"d`fr ygfj;k pknjsa nks cxyh
p<+ko ygj ds lkFk] dksp ispksa o
pknj jfgr dksbZ eksVkbZ
vY;qfefu;e ok'kjksa ls Nr ;k nhokj
dksbZ eksVkbZ
vkfn esa( vkf[kjh p<+kos 25 x 6
Rs.
Rs.
feeh tLrh yksgs ds dkoyksa dks 20
40.90
32.50
lseh dh nwjh ij yxkdj LFkkfir
11008 tksM+sa en 11007 esa ;fn ispksa ds
LFkku ij ,y gqd ;k vjky dCts
yxs gksa
13.20

8.50

CORRUGATED TRANSLUCENT SHEETING


ygfj;k IkkjHkklh pknjh dk;Z
PER SQUARE METRE

S&F

vkiwfrZ o LFkkiuk
Thickness in mm
11009 Fibre glass reinforced
translucent corrugated
sheeting
with
two
corrugations side lap fixed
with coach screw and

washer in roof, wall etc.


11010 Add to item 11009, if fixed
with L-type or J-type or
cranked hook bolts in lieu

of screw

eksVkbZ feeh esa


2mm
Rs.

izfr oxZ ehVj

Except
Labour
sheeting
only (any
(any thick- thickness)
ness)
dsoy Je

pknj jfgr dksbZ eksVkbZ 11009 rarqdkap izofyr ikjHkklh ygfj;k


dksbZ eksVkbZ
pknjsa nks cxyh p<+ko ygj ds
Rs.
Rs.
lkFk( dksp ispksa o ok'kjksa ls Nr]
nhokj vkfn esa LFkkfir

851.30

17.90

75.80

17.90

68.70

8.50

11010 tksMs+a en 11009 esa ;fn ispks ds


LFkku ij ,y gqd ;k ts gqd ;k
vjky dCts yxs gksa

PLAIN STEEL SHEETING


lknk bLikr pknjh dk;Z
The rates for flashing include for cost of embedding mortar
alongwith other labour and materials required to complete the
work.

tyjks/kh f>fYy;ksa dh njksa esa] elkyk yxkus lkFk gh dk;Z dks iw.kZ
djus ds fy;s vko';d vU; Je o lkexzh 'kkfey gSA

215

SECTION 11

SECTION 11ROOF COVERING


[k.M 11&Nr vkPNknu
PLAIN STEEL SHEETING-Contd...
lknk bLikr pknjh dk;Z tkjh
PER SQUARE METRE

S&F

vkiwfrZ o LFkkiuk
Thickness in mm

11011 Plain, black, mild steel


eksVkbZ feeh- esa
sheeting, in ridges,
hips, valley gutters,
1.00 1.25
drip and straight 0.63 0.80
Rs.
Rs.
Rs.
Rs.
flashings (length and

girth as fixed)
300.80 371.40 451.40 550.10
11012 Plain, galvanised, mild
steel sheeting, in ridges,
hips, valley gutters, drip
and straight flashings
(length and girth as
fixed) with grade of

zinc coating 275


346.70 413.80 496.10
11013 Plain, black mild steel
sheeting in stepped
flashings (measured as
the minimum rectangle
from which the pieces

can be cut)
335.10 405.80 489.10 587.80
11014 Plain, galvanised, mild
steel sheeting in stepped
flashings (measured as
the minimum rectangle
from which the pieces

can be cut)
372.20 448.20 530.40
11015 Add to items 11011,
11012, 11013 and
11014 if welded or
soldered joints are
53.80
provided

66.50

77.30 93.70

Except Labour
sheeting only (any
(any
thickness
thicknes) dsoy Je

pknj jfgr dksbZ


dksbZ eksVkbZ eksVkbZ
Rs.

Rs.

53.20

36.00

53.20

36.00

89.80

72.60

89.80

72.60

22.90

22.90

izfr oxZ ehVj


11011 lknk] dkyh] uje yksgs dh
pknjksa dk dk;Z dVdks]a dkfB;ks]a
?kkVh xVjksa o lh/kh o fu;krh
f>fYy;ksa esa LFkkfir yEckbZ o
pkSMk+ bZ
11012 lknk] tLrsnkj] uje yksgs dh
pknjksa dk dk;Z dVdks]a dkfB;ksa
?kkVh xVjksa o lh/kh o fu;krh
f>fYy;ksa esa LFkkfir yEckbZ o
pkSM+kbZ fuEu Js.kh dh

11013 lknk] dkyh uje bLikr dh


pknjks a dk dk;Z lh<+ h nkj
f>fYy;ksa esa ml lcls NksVs
vk;rkdkj [kaM dks ekik tk;sxk
ftlesa ls og cuh gks
11014 lknk] tLrsnkj] uje bLikr
dh pknjksa dk dk;Z lh<+hnkj
f>fYy;ksa esa ml lcls NksVs
vk;rkdkj [kaM dks ekik tk;sxk
ftlesa ls og cuh gks fuEu
Js.kh dh
11015 tksMsa+ ensa 11011] 11012] 11013
vkSj 11014 esa ;fn tksM+ksa esa
>ky ;k Vkadk yxk;k gks

216

SECTION 11

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
PLAIN, ALUMINIUM SHEETING
lknk vY;qfefu;e pknjh dk;Z
S&F
vkiwfk o LFkkiu
Thickness in mm
11015A Plain,
Aluminium eksVkbZ feeh esa
sheeting, Alloy 31000 H4
0.56
0.71
in ridges, hips, valley
Rs.
Rs.
gutter, drip and straight
flashing (length and
322.29 404.54
girth as fixed)
11016 Plain
Aluminium
sheeting Alloy 31000
H4 in stepped flashing
(meas u r e d a s t h e
m i n i m u m rectangle
from which the pieces

can be cut)
356.65 438.90
PER SQUARE METRE

GALVANIZED SHEETING

Except sheet
-ing (any
thickness)
pknj jfgr

Labour only
(any thickness)
dsoy Je

dksbZ eksVkbZ

dsoy eksVkbZ

Rs.

Rs.

53.74

36.58

89.79

68.24

S&F
Rs.

Except sheeting
(any thickness)

Labour only
(any
thickness)

646.00

57.90

34.40

510.20

57.90

34.40

PER SQUARE METRE


11017 Pre- painted galvatume
aluminum zinc coating GI
based corrugated steel
sheet 0.50mm thick of an
colour having tensile
strength of 550 Mpa as in
roof covering/cladding to
wall, fixed with self
tapping
screws
as

specified
11018 Pre-painted galvalume
aluminum zinc coating GI
based Plain steel sheet
0.50mm thick of any
colour having tensile
strength of 550 Mpa as in
roof covering/cladding to
wall, fixed with self
tapping
screws
as

specified

izfr oxZ ehVj


11015, lknk vY;qfefu;e feJ/kkrq
31000 ,p&4 dk pknjh dk;Z
dVdksa] dkfB;ksa] ?kkVh xVjksa]
fu;krh o lh/kh f>fYy;ksa esa]
LFkkfir yEckbZ o pkSMk+ bZ
11016 lknk vY;qfefu;e] feJ/kkrq
31000 ,p&4 dk pknjh dk;Z
lh<+hnkj f>fYy;ksa esa ml lcls
NksVs vk;r dks ekik tk;sxk
ftlls og [kaM cu ldrk
gS

SECTION 11

217

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
ASBESTOS CEMENT SHEETING-GREY

,sLosLVl lhesaV pknjh dk;Z Hkwjh

PER SQUARE METRE

Fixed with coach


screws
dksp ispksa ls LFkkfir

Fixed with L-type or


J-type or cranked
hook bolts
L gqd ;k J gqd vjky dCts LFkkfir

M&L Except Labour M&L Except Labour


lkexzh sheets only
lkexzh sheets only
o Je pknj
dsoy Je o Je pknj
dsoy Je
11019 6mm thick asbestos
jfgr
jfgr
cement, corrugated or
Rs.
Rs.
Rs.
Rs.
Rs.
semi-corrugated sheets in Rs.

roofs, walls etc.


234.90 40.80 38.40
239.00 45.10
41.30

izfr oxZ ehVj

11019 6 feeh eksVh ,LosLVl lhesaV


dh ygfj;k ;k v/kygfj;k pknjsa
Nrksa] nhokjksa vkfn esa

R.M.P. SHEETING

vkj ,e ih pknjh dk;Z


PER SQUARE METRE
11020 RMP sheeting 1.5 mm
thick with 1.5 corrugation
side lap fixed with coach
screw and PVC washer

in roof, wall etc.


11021 Ditto, if fixed with L-type
or J-type or cranked hook
bolts in lieu of screw

S&F
vkiwfrZ o
LFkkiu

Rs.

Except
sheeting (any
thickness)
pknj jfgr
dksbZ eksVkbZ

Labour
only (any
thickness)
dsoy Je
dksbZ eksVkbZ

Rs.

Rs.

398.90

75.80

68.70

373.80

50.60

42.40

izfr oxZ ehVj


11020 vkj ,e ih pknjh dk;Z( Ms<
feeh ik'oZ ygfj;k p<+ko ds lkFk]
1-5 feeh eksVh] dksp isp vkSj
ihohlh ok'kj ls Nr nhokj vkfn
esa LFkkfir
11021 mi;qZDr] ;fn isp ds LFkku ij
,y gqd ;k ts gqd ;k vjky
dCts LFkkfir

218

SECTION 11

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
ASBESTOS CEMENT ACCESSORIES-GREY

,sLcsLVl lhesaV pknjh dk;Z & Hkwjh

nks [kaMh; lek;kstd esMk+ as dwVa ksa dsk ,d gh yEckbZ esa ekik tk;sxk
iz f r ehVj
Fixed with L-type or J-

Two-piece adjustable ridges shall be measured as one length.


PER RUNNING
METRE

Fixed with coach screws

type or cranked hook


bolts
dksp ispksa ls LFkkfir
,y gqd ;k ts gqd ;k vjky dCts
LFkkfir
M&L Except
Labour M&L Except
Labour
lkexzh accessory only
lkexzh sheet only only
,oa Je pknj jfgr dsoy Je ,oa Je pkjn jfgr dsoy Je

11022 Asbestos cement oneRs.


Rs.
piece plain angular
162.50 25.50
ridge 6mm thick

24.40

165.20 27.50

26.50

11023 Asbestos cement twopiece adjustable plain


227.50 25.50
wing ridge 6mm thick

24.40

228.30 27.50

26.50

11024 Ditto unserrated ridge


230.10 26.00
for hips

24.40 231.70 28.10

26.50

11025 Ditto serrated ridge for


corrugated or semi
corrugated sheets 224.20 26.00

24.40 226.20 28.10

26.50

11026 Ditto close fitting


238.30 26.00
corrugated sheets only

24.40 240.30 28.10

26.50

11027 Asbestos cement apron


piece 6mm thickness to
suit corrugated or semi
corrugated sheets 230.10 59.70
11028 Asbestos cement barge
boards and corner
pieces for corrugated or
semi-corrugated sheets.
fixed with seam bolts

and nuts
EACH
11029 Asbestos cement cowl
type ventilator fixed to
corrugated or semicorrugated sheets with
seam bolts and nuts

Rs.

Rs.

Rs.

Rs.

11022 ,sLcsLVl lhesaV ,d [kaMh;


lknk dks.kh; dwV 6 feeh
eksVh
11023 ,s L cs L Vl lhes a V f}[a k Mh
lek;kstu ;ksX; lknk ia[kh
dwV 6 feeh eksVh
11024 mi;qZDr] p<+koksa ds fy;s fcuk
nkars dh dwV
11025 mi;qZDr] ygfj;k ;k v/kZ
ygfj;k pknjksa ds fy;s nkarns kj
dwV
11026 mi;qDZ r] dsoy ygjf;k pknjksa
ds fy;s LFkkiu miLdj
11027 ygfj;k ;k v/kZ ygfj;k pknjksa
ds fy;s ,LosLVl lhesaV ds
vkoj.k [kaM 6 feeh eksVh

50.00 234.10 63.70

60.60

Materials
Except
& Labour ventilator
lkexzh ,oa
jkskunku
Je
jfgr

Labour
only
dsoy Je

Rs.

Rs.

Rs.

249.00

72.70

63.50

54.00

55.10

11028 ygfj;k ;k v/kZ ygfj;k pknjksa


ds fy;s] lhou dkoys f<ofj;ksa
ls tqMs+ ,LosLVl lhesVa frdksus
Qyd
iz R ;s d
11029 ygfj;k ;k v/kZ ygfj;k pknjksa
esa lhou dkoyksa o f<ofj;ksa ls
yxs ,Los L Vl lhes a V ds
Vksihnkj jks'kunku

219

SECTION 11

SECTION 11 ROOF COVERING


[k.M 11& Nr vkPNknu
ASBESTOS CEMENT ACCESSORIESGREYContd...
,sLcsLVl lhesaV iwjd lkexzh dk;Z&Hkwjh tkjh
Fixed with L-type or J-type or
cranked hook bolts

PER RUNNING METRE

iz f r ehVj

,y gqd ;k ts gqd ;k vjky dCts }kjk LFkkfir


11030 Asbestos cement north light
curves to suit asbestos cement
sheets, fixed with seam bolts
and nuts in
11031 Asbestos cement eaves filler
pieces to suit corrugated or
semi-corrugated sheets in

EACH
11032 Asbestos cement ridge finials
fixed with 6mm G.I. bolts (two
pieces for semi-corrugated sheets

measured as one)
11033 Asbestos cement curved barge
board for North light curves
fixed with seam bolts and
nuts

M&L

Except accessory

lkexzh ,oa Je

iwjd lkexzh jfgr

Rs.

Rs.

194.10

35.50

130.20

25.50

M&L

lkexzh ,ao
Je
Rs.
148.30

Except
accessory

11030 ,sLcsLVl lhesaV pknjksa ls mi;qDr]


lhou o gqd ;k vjky dkoyksa ls yxs
,sLcsLVl lhesaV mkjh izdk'k eksM+
11031 ygfj;k ;k v/kZ] ygfj;k pknjksa ds
mi;qZDr ,sLcsLVl lhesaV ds vksyrh
iwjd [kaV

iz R ;s d

iwjd lkexzh jfgr 11032 6 feeh th vkbZ dkoyksa ls dls ,sLcsLVl


lhesVa ds fjt dy'k v/kZ ygfj;k pknjksa
Rs.
ds nks [kaM ,d ds leku ekis tk;sx
a s
30.80

11033 ,sLcsLVl lhesVa ds] mkjh izdk'k eksM+ ds


fy;s] o cktZ cksMZ
189.40

35.50

EXTRA TO CORRUGATED MILDSTEEL SHEETING, ALUMINIUM CORRUGATED


SHEETING AND ASBESTOS CEMENT CORRUGATED OR SEMI-CORRUGATED
SHEETING (ANY DESCRIPTION OR THICKNESS)
vfrfjDr] ygfj;k uje bLikr pknj] vYewfu;e ygfj;k pknj] o ,LcsLVl lhesaV pknj ;k v/kZ ygfj;k
pknj dk;Z fdlh Hkh o.kZu ;k eksVkbZ ij
(a) Linear dimensions for notching, raking cutting, etc., shall
be measured on the flat and not girthed to corrugation.
No addition shall be made for any laps cut through. The
work shall be executed in position, if necessary, without
extra charge.
(b) If cutting is made on sheets issued for fixing only by M.D.
rates under column 'Labour only' as applicable shall be
allowed.

d [kkapsnkjh] voueu] dVkbZ vkfn dh ijeikfjd ifjeki likV


ij fy;k tk;sxk u fd ygjksa esa f?kjk gqvkA vkjikj dVs p<+koksa
ds fy;s dqN ugha tksM+k tk;sxk ;fn vko';d gks rks fcuk
vfrfjDr [kpZ ds dk;Z LFkku esa fuLikfnr gksxkA
[k ;fn ,e Mh }kjk dsoy LFkkiu ds fy;s nh xbZ pknjksa esa dVkbZ
dh tkrh gS rks *dsoy Je* ds dkye esa nh xbZ njsa ns; gksaxhA

220

SECTION 11

SECTION 11 ROOF COVERING


[k.M 11& Nr vkPNknu
EXTRA TO CORRUGATED MILDSTEEL SHEETING, ALUMINIUM CORRUGATED
SHEETING AND ASBESTOS CEMENT CORRUGATED OR SEMI-CORRUGATED
SHEETING (ANY DESCRIPTION OR THICKNESS) Cont...
vfrfjDr] ygfj;k uje bLikr pknj] vYewfu;e ygfj;k pknj] o ,LcsLVl lhesaV pknj ;k v/kZ ygfj;k
pknj dk;Z fdlh Hkh o.kZu ;k eksVkbZ ij& tkjh--PER RUNNING METRE
11034 Raking cutting and
waste; or straight
cutting and waste
to square abutments,
door and window
openings, sky lights,
chimney stacks etc.
exc 0.4 sq. m each (not
allowed when
a
square cut extends
the full length or
width of a sheet)
11035 Circular cutting and
waste exc 0.4 sq.m

each
PER 100 NOS.

11036 Cutting (straight,


raking or circular)
notches or holes of area
not exc 100 sq. cm
11037 Ditto area exc 100 sq.
cm but not exc 400 sq.

cm
11038 Ditto area exc 400 sq.
cm

Corrugated steel
sheeting

Asbestos cement corrugated


or semi-corrugated sheeting

ygfj;k bLikr pknj


dk;Z

,LosLVl lhesaV ygfj;ka v/kZ


ygfj;k pknj dk;Z

M&L

Labour only

M&L

lkexzh
,oa Je

dsoy Je

lkexzh ,oa
Je

Rs.

Rs.

Rs.

65.70

14.50

63.00

98.80

22.30

Corrugated
steel sheeting

ygfj;k bLikr
pknj dk;Z

iz f r ehVj

11034 oxkZdkj vk/kkjks]a njokts o


f[kM+fd;ksa ds chcjks]a Nr
eks[kks]a fpeuh xfjZ;k vkfn
Labour only
ds 0-4 oeh ls vf/kd dh
dsoy Je
frjNh dVkbZ o Nhtu lh/
kh dVkbZ o Nhtu tc
Rs.
oxhZ dkV pknj dh iwjh
yEckbZ ;k pkSM+kbZ rd
tk, rks Lohd`r ugha gksxk
22.80

94.20

38.30

Asbestos cement
corrugated or semi
corrugated sheeting

,sLosVl lhesaV dh ygfj;k]


v/kZ ygfj;k pknj dk;Z

Rs.

Rs.

566.30

909.80

850.40

1364.70

1420.90

2279.80

11035 izR;sd 0-4 oeh ls vf/kd


dh xksykdkj dVkbZ o Nhtu
fr 100 la[;k

11036 100 olseh vuf/kd {ks=Qy


ds voueu ;k Nsn dVkbZ
lh/kh] frjNh ;k xksykdkj

1 1037 mi;ZqDr] 100 o lseh ls


vf/kd fdUrq 400 o lseh
ls vuf/kd {ks=Qy
11038 mi;qZDr] 400 o lseh ls
vf/kd {ks=Qy

221

SECTION 11

SECTION 11 ROOF COVERING


[k.M 11& Nr vkPNknu
EXTRA LABOUR ON STEEL, ALUMINIUM AND ASBESTOS CEMENT SHEETING
bLikr] vY;qfefu;e o ,sLosLVl pknjh dk;Z ij vfrfjDr Je
PER RUNNING METRE

Rs.

11039Levering up edges of old plain or corrugated


sheets (end or side) fixed to wood or steel
framing, inserting end or side edge of new
(sheet supplied by the M.D. for fixing only)
and nailing, screwing, bolting or riveting
including making good the joint between old
and new sheets. (Not to be allowed for work

measured as in patches)

12.70

PER 100 NOS.

Rs.

11040Closing bolt holes etc. in old corrugated steel


sheets or Aluminium sheeting by sealing
with one bitumen and one curved GI washer
on either side and 6mm G.I. bolts and nuts,
all set in stiff white lead, bolt n exc 25mm in

length
518.80
11041Closing bolt holes or other similar holes in
old Asbestos cement sheets by sealing with
one bitumen and one plain G.I. washer on
either side and 8mm dia bolt and nut, bolt
not exceeding 25mm in length (Ditto)
11042Drilling holes upto 12mm dia in plain or
corrugated sheets supplied by the Ministry

of Defence for fixing only

455.80

106.00

11043Bitumastic gola, with 80/25 bitumen and


coarse sand mixture. 1:3 by weight, 8cmx8cm

at the junction of roofing to vertical surfaces

fr 100 la[;k
11040 iqjkuh ygfj;k bLikr pknjksa ;k vYeksfu;e pknjksa ds
dk;Z esa dkoys ds Nsnksa dks nksuksa vksj ,d foVqfeu o
,d o tLrh yksgs ds ok'kj ls can djuk rFkk 6 feeh
ds tLrh yksgs ds dkoys o f<ofj;ka lHkh dks lQsns ls
vPNh rjg l[r djuk] dkoys 25 feeh ls vf/kd ugh
mi;qZDr
11041 iqjkuh ,sLosLVl lhesaV pknjksa dks] nksuksa vksj ,d
foVqfeu o ,d lknk tLrh yksgs dh ok'kj rFkk 8 feeh
O;kl ds dkoys o f<ofj;k yxkdj cUn djuk] dkoys
25 feeh yEckbZ ls vf/kd ds u gksa mi;qZDr
11042 j{kk ea=ky; }kjk dsoy LFkkiu ds fy;s nh xbZ lknk
;k ygfj;k pknjksa esa 12 feeh O;kl rd ds ojHkkbZ
Nsn djuk] mi;qZDr
fcVqeSfLVd xksyk rkjdksyh xksyk

BITUMASTIC GOLA
PER RUNNING METRE

fr ehVj
11039 iqjkuh lknk ;k ygfj;k pknjksa ds fdukjksa Nksj ;k
ik'oZ dks ij mBkuk ydM+h ;k bLikr ds pkS[kVksa esa
yxkuk] ubZ pknj dsoy LFkkiu ds fy;s ,e Mh }kjk
nh xbZ Nksjksa ;k ik'oZ fdukjksa dks vUnj Mkyuk rFkk
iqjkuh o ubZ pknj ds chp ds tksM+ dks ifj"d`r djus
lfgr] dhy] isp dkoys ;k fjfiV yxkuk isouksa esa
ekis x;s dk;Z es btktr ugha gksxh

Rs.

123.60

izfr oxZ ehVj


11043 fopqfeuh xksyk 80@25 rkjdksy o eksVh ckyq ds
feykos 1%3 ctu dk] Nr ds laxejej lekUrj lrgksa
esa 8 X 8 lseh

ROOFING TILESMANGALORE PATTERN


Nr ds [kijs eaxykSjh vkd`fr
(a) The rates do not include for:
(i) Tile battens, boarding or other supports for tiling,
(ii) Concrete or mortar fillets along parapets, chimney
stacks, etc.
(b) The rates include for a tile and half tile at verges and cutting
holes through tiling for pipes, including making good.

d njksa esa ;g 'kkfey ugha gS%&


i cfYy;ka] r[rscanh ;k [kijs dk;Z ds vU; lgkjsA
ii eaqMsjksa] fpefu;ksa ds lkFk dh dhV ;k elkys dh HkjkbZ
[k njksa es]a fdukjksa dh Ms< [kijh] uyksa ds fy;s [kijh esa Nsn djuk
o mls Bhd djuk 'kkfey gSA

(c) If tiles are required to be wired with 1.6mm galvanised


wire in lieu of screwing, half the rate of item 1386 shall be
paid.

x isp dlkbZ ds LFkku ij ;fn [kijksa dh rkj ca/kkbZ djuh gS 1-6


feeh tLrh rkjksa ls rks en 1386 dh vk/kh njksa ij Hkqxrku gksxkA

222

SECTION 11

SECTION 11 ROOF COVERING


[k.M 11& Nr vkPNknu
ROOFING TILESMANGALORE PATTERNContd...
Nr ds [kijs eaxykSjh vkdkj tkjh
PER SQUARE METRE

M&L

Except tiles

lkexzh ,ao
Je

[kijs jfgr

11044Roof tiles, Mangalore pattern,

interlocking at side joints, laid dry

Rs.

Rs.

193.10

36.80

11045Ceiling tiles for Mangalore pattern

tile roofing, laid dry

217.70

36.80

PER RUNNING METRE

M&L

Except tiles

11046Ridge or hip tiles to suit Mangalore


pattern of roofing tiles, bedded and
jointed in lime mortar 1:3 or cement

mortar 1:6

lkexzh ,ao Je

[kijs jfgr

Rs.

Rs.

95.10

25.20

14.00

10.80

11048Raking cutting and waste to hips,

valleys, etc.

22.10

16.20

PER 100 NOS.


11050Screwing eaves tiles (each tile
screwed) to eaves battens with galvanised iron screws, GI and
bitumen washers including drilling

holes in tiles

11044 eaxykSjh fdLe dh Nr [kifj;ksa dh van:uh


ik'oZ tksM+ lfgr lw[kh fcNkbZ
11045 eaxykSjh fdLe dh [kifj;ksa dh Nr ds
fy;s lhfyax [kijksa dh lw[kh fcNkbZ
iz f r ehVj
11046 eaxykSj fdLe [kijSy ds mi;qDr fjt ;k
fgi [kijksa dks fcNkdj 1%3 ds pwuk elkys
;k 1%6 ds lhesaV elkys ls tksM+kbZ
11047 lh/kh dVkbZ o Nhtu oxkZdkj vk/kkj LrEHkks]a
fpefu;ksa mikarksa vkfn esa

11047Straight cutting and waste to


square abutments, chimney stacks,

verges, etc.

11049Extra over tiling for eaves tiles or


verges, bedded in lime mortar 1:3 or
cement mortar 1:6 to old brick-work

or masonry

izfr oxZ ehVj

11.10

11048 frjNh dVkbZ o Nhtu] iqVBksa] ?kkfV;ksa


vkfn esa
11049 vfrfjDr vkSfYr;ksa ;k mikarksa ds [kijksa ds
fy;s] 1%3 ds pwuk elkys ;k 1%6 ds lhesaV
elkys ls iqjkus bZVa dk;Z ;k iRFkj fpukb;ksa
esa fcNkbZ ij

689.70

izfr 100 la[;k


11050 tLrh bLikr ds ispksa ls tLrh yksgs ds
foVqfeu ok'kjksa ds lkFk [kijksa es ojes ls
Nsn djds vksyrh ds [kijksa esa isp yxkuk
gj [kijs esa isp dlkbZ

Rs.

MUD PHUSKA

xkjs dk Qqldk
izfr oxZ ehVj

PER SQUARE METRE


Rs.
1105180mm thick average consolidated
thickness, mud phuska on flat roofs
including 25mm thick mud plaster
and 3 mm thick leeping plaster

48.40

11052Add to or deduct from last for every


10mm thickness of mud phuska over

or under 80mm average thickness

6.50

11051 80 feeh vkSlr eksVk lekfgr eksVkbZ dk


likV Nrksa ij xkjk Qqldk mlds ij
25 feeh eksVk xkjk iyLrj o 3 feeh
eksVh fyikbZ
11052 tksM+sa ;k ?kVk;sa] vafre en esa ls] xkjk
Qqlds dh 80 feeh eksVkbZ ls 10 feeh de
;k vf/kd eksVkbZ ds fy;s

223

SECTION 11

SECTION 11 ROOF COVERING


[k.M 11& Nr vkPNknu
MUD PHUSKA

xkjs dk Qqldk
Rs.

11053Deduct from item 11051 if leeping

plaster is not provided

7.40

11054Cutting or uprooting grass on old


mud phuska, removing rubbish
off the premises, cleaning surface
and preparing to receive new mud

plaster

3.40

1 1053 ?kVk;s] en 11051 esa ls ;fn fyikbZ iyLrj


ugha fd;k x;k gSA
11054 iqjkus xkjs Qqlds ij ls ?kkl m[kkM+uk]
ifjlj ls eyok gVkuk] lrg lkQ djuk
rFkk mls u;k xkjk iyLrj yxkus ds fy;s
laokjuk

BRICK TILE TERRACING

ckjts cukbZ esa bZV Vkby


The rates for brick tiling include for all straight, raking and
circular cutting and waste.
PER SQUARE METRE

M&L

1105540mm thick brick tiles laid on mud


mortar and joints grouted flush in
cement mortar (1:3) mixed with 5%
of crude oil by weight of cement on

mud phuska

lkexzh ,ao
Je

11056Add to item 11055 if tiles are bedded


in cement mortar (1:6) or lime mortar

(1:3), 15mm thick

bZV Vkby dh njksa esa LkHkh lh/kh] frjNh o xksy dVkbZ o Nhtu 'kkfey
gSA
izfr oxZ ehVj
Except tiles
Vkby jfgr 11055 40 feeh eksVh bZV Vkbysa feV~Vh xkjs ij

Rs.

Rs.

224.50

96.40

124.40

124.40

BITUMEN TACK COAT

Rs.

11057Applying evenly a tack coat of in


dustrial bitumen 85/25 at the rate of
1.2 kg per sq.m including cleaning

surfaces

54.60

PER CUBIC METRE

11058Lime concrete terracing as specified in


roof (excluding bitumen tack coat)

M&L

fcNh rFkk tksM+ 1%3 ds lhesVa ds ctu dk


5% dPps feJ.k ls Hkjs gq;s

11056 tksMsa+ en 11055 esa ;fn Vkbyksa dks 1%6


lhesaV elkys ;k pwuk elkys 1%3 esa 15
feeh eksVkbZ es fcNk;k x;k gS
rkjdksy dk fpidk ijr
1 1057 lrg dh lQkbZ lfgr O;olkf;d rkjdksy
dk 85@25] 1-2 fd0xkze izfr oxZ ehVj dh
nj ls ,d fpidk Lrj yxkuk

Except
aggregate

lkexzh ,ao
Je

feykos jfgr

Rs.

Rs.

2790.40

2165.80

izfr ?ku ehVj

11058 pwuk dhV] Nr tSlh fufnZf"Vr okjtksa esa(


dksyrkj dh fpidk ijr NksM+dj

PER SQUARE METRE

Rs.

izfr oxZ ehVj

11059 Extra over lime concrete terracing for


top surface trowelled smooth

10.60

11059 vfrfjDr] okjtksa dh ijh lrg dh dwV


dj le cukus ds fy;s

224

SECTION 11

SECTION 11 ROOF COVERING


[k.M 11& Nr vkPNknu
STONE SLAB ROOFING

iRFkj ifV;k Nr vkPNknu


(a) The rates for stone slab roofing includes for all straight,
raking and circular cutting and waste.
(b) Thickness between 30mm and 50mm shall be paid
prorata.
Jointed in

PER SQUARE METRE

d iRFkj dh ifV;ksa ds Nr vkPNknu dk;Z esa lHkh lh/kh] frjNh o


xksykdkj dVkbZ 'kkfey gSaA
[k 30 feeh ls 50 feeh ds chp dh eksVkbZ dk Hkqxrku vkuqikfrd
gksxkA
var% tqM+kbZ

izfr oxZ ehVj

Lime mortar 1:3

Cement mortar 1:4

pwuk elkyk 1%3

lhesaV elkyk 1%4

M&L

Except slab

M&L

Except slab

ifV;k jfgr

lk ,oaa
Je

ifV;k jfgr

11060 30mm thick sand stone


slabs; set and jointed over
joists, etc., complete

lk ,oaa
Je
Rs.
209.90

Rs.
104.10

Rs.
211.40

Rs.
105.70

11061 Ditto but 50mm thick

321.70

145.40

324.10

147.80

11060 30 feeh eksVh ckyq iRFkj ifV;k


dfM+;ksa vkfn ij fLFkj o tqMh+ gqbZ
laiw.kZ
11061 mi;qZDr] fdUrq 50 feeh eksVh

REPAIRS AND WATERPROOFING TREATMENT TO TERRACED ROOFS


[kqyh Nrksa dh ejEer o tyjks/kh mipkj
REPAIRING OF CRACKS
PER RUNNING METRE
11062 Cutting out cracks to V-section in
existing roofs or terracing, cleaning
out, wetting, grouting with cement
and sand slurry 1:3

11063 Cutting out cracks to V-section in


existing roofs or terracing, cleaning
out and filling solidly with a hot
mixture of bitumen and clean dry

sand 1:1 (by weight)

M&L

Labour
only

lkexzh ,ao
Je

Je dsoy

Rs.

Rs.

31.30

29.60

48.90

31.40

lrg jksxu dk;Z

SURFACE PAINTING
PER SQUARE METRE

M&L

11064 Wire brushing and cleaning top lkexzh ,ao


Je
surface of tiles, lime terracing or cement
concrete, including flashings and
junction of parapets, etc., and surface
painting, with a layer of blown grade
bitumen of any penetration applied
hot @ 1.7 kg per sq. m, blinded with
grit or pea size gravel @ 0.006 cu.m per
sq.m, and lightly tampered (area of
flashings, etc., shall be added to the

roof area)

njkjksa dh ejEer
iz f r ehVj
11062 fo|eku Nrksa ;k okjtksa esa V dkV dh
njkj dkVuk] mudh lQkbZ djuk] xhyk
djuk] 1%3 ds lhesaV o ckyq ds irys
?kksy ls lysjh djuk
11063 fo|eku Nrksa ;k okjtksa esa V dkV dh
njkj dkVuk] mUgsa lkQ djuk rFkk 1%1
ds rkjdksy o lkQ ckyq Hkkfjr ds xeZ
feJ.k ls Bksl HkjkbZ djuk

Rs.

76.70

Except
bitumen

izfr oxZ ehVj


11064 f>fYy;ksa o eaM
q js ksa ds tksMk+ as lfgr] Vkbyksa
rkjdksy jfgr
dh
ijh
lrg]
pwuk ;k lheaV dahV
Rs.
okjtksa] dh rkjh czq'k ls lQkbZ djuk]
fdlh Hkh izHkko ds Qwd
a s xeZ rkjdksy dks
1.7 fdxzke izfr oeh iRFkjh drju 0.006
?keh izfr oeh ds fglkc ds feykos dks
FkksM+k xeZ djds HkjkbZ djuk f>fYy;ksa
vkfn dk {ks= Nr ds {ks= esa tksM+k
9.80
tk;sxk

225

SECTION 11

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
BITUMEN FELT WATERPROOFING TREATMENT
uenk rkjdks y h tyjks / kd mipkj
(a) Measurements shall be for the surface of roof and vertical,
curved or battered faces of parapet walls, abutments,
chimney stacks, breasts, drain mouths, gutters, flashings,
etc., covered with the waterproofing treatment. Turn ups
and turn downs at eaves, verges, abutments, flashings,
aprons, gutters, hips ridges, valleys, etc., shall be measured
alongwith waterproofing treatment.

tyjks/kd mipkj ds varxZr vkus okys Hkkx] Nr dh lrg


o lekukUrj o ;k frjNh] daxjw h fnokjks]a /kkjdks]a fpefu;ksa
ds /kM+ iz"B] ukfy;ksa ds eq[k] xVj] njkjsa vkfn dh eki yh
tk;sxhA vksfYr;ksa ds mrkj p<+ko] fdukjs vk/kkj] njkjsa
vkoj.k] xVj] mBkoh p<+kos] ?kkfV;ka vkfn dh eki tyjks/kd
mipkj ds lkFk gksxhA

(b) Rates include for end and side laps, forming of openings,
tucking in, wedging and pointing edges, tucked in
brickwork or concrete fillet, all cutting and waste, and work
in any position and any shape.

[k

(c) Cutting grooves or chases in brick-work and shaping


grooves for tucking in edges of felt, etc. shall be measured
separately.
(d) Concrete fillets at junctions between roof and parapet walls,
around obstacles, chimney slacks, etc., shall be measured
separately.

njksa esa Nksj o ik'oZ mHkkj] lajpuk] VadkbZ] fdukjksa dh HkjkbZ


o VhiVki] bZV dk;Z ;k dahV ifV~V;ksa esa Vadkb lHkh
dVkbZ o Nhtu rFkk fdlh voLFkk ;k fdlh vkdkj esa dk;Z
'kkfey gSA
bZV dk;Z esa Nsn ;k f>jh fudkyuk rFkk VadkbZ ds fy;s Nsnksa
dks vkdkj nsuk i`Fkd ekis tk;saxsA

(e) Plastering to surfaces for preparing, and filling up


cracks shall be measured separately only when performed
over old/existing roofs.
PER SQUARE METRE

M&L

M-

laifw rZ ds fy;s lrgksa ij iyLrj djuk rFkk njkjksa dh HkjkbZ


izFkd rHkh ekih tk;sxh tc iqjkuh@fo|eku Nrksa ij dk;Z
fd;k x;k gksA

uenk jfgr

Rs.

Rs.

233.00

144.90

411.50

235.30

PER RUNNING METRE


11067 Cutting grooves in brick wall, 75mm wide and
65mm deep and shaping horizontal face of

groove with cement mortar 1:3


PER SQUARE METRE
11068

Nr o nhokj eqaMsjksa laxeksa vojks/kksa fpeuh vkfn ij dahV


ifV~V;ksa dks i`Fkd ekik tk;sxkA

Except felt

11065 Priming surfaces and applying lk ,oa Je


normal treatment (for moderate
conditions) using glass fibre base

bitumen felt, grade 2


11066 Priming surfaces and applying
heavy treatment (for severe

conditions), ditto

?k

APP based polymeric membrane minimum


weighing 3kg/sqm and minimum 3mm thick
reinforced with polyster non wove fabric (wt. not
less than 150 gms/sqm) land on primed surface
by forced application complete all as specified.

Rs.

25.20
Rs.

171.80

izfr oxZ ehVj


11065 vLrjh; vLrj rFkk dkap js'kk vk/kkj uenk
Js.kh 2 dk iz;ksx djds lkekU; mipkj
lkekU; voLFkk esa
11066 vLrjh; vLrj Hkkjh mipkj iz ; ks x
vlkekU; voLFkkvksa esa mi;qZDr

iz f r ehVj
11067 75 feeh pkSMs+ o 65 feeh xgjs Nsn bZV dk;Z esa
dkVuk rFkk lhesaV elkys 1%3 ls Nsnksa dks likV
vkdkj nsuk

226

SECTION 11

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
SHINGLE ROOFING
Nknu iV~ V h
The rates include for double course at eaves and for special
shingles to verges and also for all cutting and waste.
PER SQUARE METRE

bu njksa esa vksyfr;ksa esa nksgjh ioZ dk;Z rFkk fdukjksa dh fo'ks"k Nknu
iV~Vh ,oa lHkh dVkbZ o Nhtu 'kkfey gSA

Material & labour

Except shingles,
any timber

lkexzh o Je
Soft wood

Hard wood

uje ydM+h

dBksj ydM+h

11069Roofing
with
2nd class
wooden shingles
f} Js.kh
nailed to battens
(Battens measured
Rs.

separately)

izfr oxZ ehVj

iV~Vs] ydM+h jfgr

3rd class

2nd class

f= Js.kh

f} Js.kh

Rs.

Rs.

Rs.

78.90

11069 ydM+ h dh Nknu


ifV~V;ksa dks dhyksa ls
ckks a es a yxkdj
vkPNknu djuk okksa
dh eki izFkd gksxh

MATTING, THATCH, BAMBOO WORK, ETC.


twV pVkbZ Qwal] ckal vkfn ds dk;Z
MATTING
pVkbZ
The rates include allowance for laps and all cutting and njksa esa xkaBksa dh NwV vkSj lHkh dVkbZ o Nhtu kkfey gSA
waste.

izfr oxZ ehVj

PER SQUARE METRE


Material & Labour, Matting of

Except
matting
any type

pVkbZ] lkexzh ,oa Je

11070Matting, single
layer, and fixing to
frames or supports
with munj or other
approved string
11071Ditto, double layer,

ditto

fdlh pkVbZ
jfgr

Split bamboo
or reed

Bamboo strip or flat


leaf (chattai, etc.)

Whole
reeds

ckal [kiPph
;k ljdaMs

ckal ioZ ;k ikh Nrjh


vkfn

iwjs
ljdaMs

Rs.
50.80

Rs.

Rs.

Rs.
3.80

101.50

7.50

11070 bdgjh ijr dk pVkbZ


dk;Z] seksa ;k lgkjksa ls
eawt ;k vU; Lohd`r
jLlh ls ca/kkbZ
11071 nksgjh ijr] mi;qZDr

227

SECTION 11

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
MATTING Contd...
pVkbZ tkjh
PER SQUARE METRE

Rs.

11072Add to M & L rates of items 11070 and 11071, if


single or double layer matting is secured to frames
or supports with and including split bamboo or

laths and cross braced with the same

18.40

11073Ditto, if single or double layer matting is wired


to supports with 1.25 to 1.60mm dia G.I wire at

45 to 60cm centres

0.50

izfr oxZ ehVj


11072 tksMsa+ en 11070 o 11071 lk- o Je dh njksa esa(
;fn bdgjh ;k nksgjh ijr pVkbZ dks seksa ;k
lgkjksa ls ckal [kifPp;ksa ;k ifk;ksa esa lqn`<+ djus
lfgr rFkk mlh ls vkjikj ca/kkbZ
11073 mi;ZqDr] ;fn bdgjh ;k nksgjh ijr pVkbZ dks
lgkjksa ls 1-25 ls 1-60 feeh O;kl tLrh rkj ls 45
ls 60 lseh dsUnzksa ij dlk xk;k gks

THATCHING
NIij Nkuk
The rates include for fillets and string (tarred) required for
fixing but do not include for the supporting bamboo
framings etc.
PER SQUARE METRE

bu njksa esa cka/kus ds fy;s Qhrs o jfLl;ka rkjdksyh 'kkfey gSa fdUrq
lgk;d ckal Qjescanh 'kkfey ugha gSA
izfr oxZ ehVj

Finished thickness

laiwfjr eksVkbZ
75mm
Rs.
11074 Thatching in roofs

11075 Ditto except thatch

PER RUNNING METRE

11076 Thatched cappings to ridges and

hips

150mm 225mm
Rs.
Rs.

84.60

96.80

109.10

54.10

66.30

78.60

11074 Qwal dk NIij fcNkuk

11075 dsoy Qwal fcNkuk

M&L

Laying only

lkexzh ,ao Je

dsoy fcNkbZ

Rs.

Rs.

48.20

20.00

iz f r ehVj
11076 igkfM+;ksa p<+kb;ksa esa Qwal ds Nr vkoj.k

228

SECTION 11

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
BAMBOO WORK (STRAIGHT OR DIAGONAL, IN ANY POSITION)
igkfM+;ksa o p<+kb;ksa esa ckal dk;Z lh/kk ;k frjNk fdlh voLFkk esa
Split bamboos (not less than 20mml0mm) laid two ways shall
be paid at twice the rates when laid one way.

ckal [kifPp;ksa 20 feeh x 10 eheh ls de ughaa nks rjQk yxh


gqbZ dk nqxuk Hkqxrku gksxk tc ,dy iFk esa yxh gksaA
izfr oxZ ehVj

Spacing, centre to centre

PER SQUARE METRE

nwjh] dsUnz ls dsUnz


11077 Whole bamboos, 90mm to
125mm mean girth, laid one
way in framing and tied se- 150mm 225mm
curely with munj or other apRs.
Rs.
183.70
proved string
131.80
11078 Ditto but except bamboos 23.00
20.10
11079 Add to items 11077 and 11078
for crude oiling bamboos
(Treated all over but measured

on the flat, one side)


13.10
10.50
11080 Split bamboos (not less than
20mm x 10 mm) laid one way
in framings and tied securely
with munj or other approved
47.90
string
36.40
31.40
11081 Ditto, but except split bamboo
11082 Add to items 11080 and 11081
for crude oiling bamboos as in
10.50
item 11079
11083 Extra for nailing or wiring
split bamboos, laid two ways,

at each intersection

PER SQUARE METRE


11084 Small whole bamboos (not
less than 50mm mean girth)
closely laid to touch adjacent
bamboos on both sides
including tying securely
with munj string
11085 Crude oiling to ditto (oiled all
over but measured on the flat,

one side only)

10.20

25.30

300mm

450mm

Rs.

Rs.

105.00

79.40

15.70

12.40

8.40

6.30

26.90

17.70

17.50

10.70

8.40

6.30

4.20

4.90

2.60

1.20

M&L

lkexzh ,oa Je

Except bamboos
or oil
(as applicable)

ckal ;k rsy
jfgr
(tSlk ykxw gks)

Rs.

Rs.

496.40

26.40

30.50

6.80

11077 90 feeh ls 125 feeh ek/; ?ksjs ds


lkcqr ckal Qjesnkjh bdgjs yxk dj
ewt
a ;k vU; Lohd`r jLlh ls etcwrh
ls ca/ks gq;s
11078 mi;ZqDr] fdUrq ckal jfgr
11079 tksM]as+ en 11077 o 11078 esa ckalksa
ij dPpk rsy yxkus ds fy;s iwjs
ckal ij yxk;k tk;sxk fdUrq ,d
rjQ ls likV ekik tk;sxk
11080 ckal [kiPph 20 X 10 feeh ls NksVh
ugha Qjesnkjh esa bdgjh yxh gqbZ
rFkk ewt
a ;k vU; Lohd`r jLlh ls
etcwrh ls ca/kh gqbZ
11081 mi;qZDr] fdUrq [kiPph jfgr
11082 tksM]+as en 11082 o 11081 es]a ckalksa esa
en 11079 dh rjg dPpk rsy yxkus
ds fy;s
11083 vfrfjDr] nksgjh yxh [kifPp;ksa dks
dhy ;k rkj ls izR;sd xkaB ij cka/kus
gsrq

izfr oxZ ehVj


1108
110844 NksVs iwjs ckal ek/; ?ksjk 50 feeh ls
de ugha nksuksa vksj ls lkFk okys ckalksa
dks Nwr gq;]s yxk;s] x;s rFkk ewt
a dh
jLlh ls etcwrh ls cka/ks gq;s
11085 dPps rsy dh iqrkbZ mi;qZDr rsy
pkjksa vksj yxsxk fdUrq ,d vksj ls
likV ekik tk;sxk

229

SECTION 11

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
HP BURNT CLAY TILE TERRACING

ckjts cukus esa nzO; O;oLFkk ls nfor nqX?k fpduh feh Vkbysa
M&L
Rs.

PER SQUARE METRE


11086 Hydraulically pressed burnt clay tile
plain of size 200x200x19/20mm
machine made laid over & including
cement mortar screed 15mm thick in
CM 1:6 mixed with water proofing
compound and jointed pointed in
CM 1:3 mixed with 5% crude oil by
weight of cement.

Except tiles
Rs.

325.40

222.60

RAINWATER GOODS

cjlkrh oLrq , a
EAVES GUTTERS AND RAINWATER PIPES GENERALLY

vksyrh xVj rFkk cjlkrh uy vkerkSj ls


(a) The lengths of gutters and pipes shall be measured net as
fixed between the fittings including short lengths; without
any allowance for cutting and waste or for portions of
gutters or pipes entering the sockets of the adjacent pipe or
fitting. Angles, nozzle pieces, swan necks and other fittings
shall be enumerated and measured separately. The rates
include for all necessary extra joints, cutting and waste.

xVjksa o uyksa dh yEckbZ;ka tSlh miLdkjksa esa yxh gksa NksVh


yEckbZ;ksa lfgr( fcuk dVkbZ o Nhtu ;k xVj o uy ds lkFk
okys uyksa esa vUnj x;s Hkkxksa gsrq NwV fn;s fo'kq ekih tk;sxhA
dks.k] uksty [kaM] gal xzhok rFkk vU; miLdkjksa dks ckn esa
fxuk tk;sxk rFkk i`Fkd ekik tk;sxkA njksa esa lHkh vko';d
vfrfjDr tksM+] dVkbZ o Nhtu 'kkfey gSA

(b) Eaves and valley gutters shall be measured along the


centre line.
(c) Union sockets (loose sockets) shall not be measured
separately.
(d) The rates of 'Fixing only' eaves gutters, rainwater pipes
etc., include for the supply of bolts, gutter bolts, screws,
washers, pipe nails, distance pieces, plugs, holder-bats (for
pipes without ears), and all jointing materials, and also for
all necessary cutting of gutters and pipes, drilling for
bolts and jointing and fixing in position. The rates for
'Supplied and fixed' include subsidiary materials
mentioned above as well as gutters, pipes and accessories,
fittings and waste in cutting gutters and pipes.

[k

vksyrh ;k ?kkVh xVjksa dks dsUnz js[kk ds lkFk&lkFk ekik tk;sxkA

;qXex lkdsV <hyh lkdsV i`Fkd ugha ekih tk;sxhA

?k

vksyrh xVj] cjlkrh uyksa vkfn dh *dsoy LFkkiu* dh njksa


esa dkoyksa] xVj dkoyksa] ispksa] ok'kjksa] uydhyksa vUrjh;
[kaM] MkVsa] ifjxzkgh vkd.kZ uyksa gsrq rFkk lHkh la;kstu
lkexzh] rFkk lHkh vko';d xVjksa o uyksa dh dVkbZ] oksYVksa
ds fy;s ojHkkbZ Nsn rFkk tqM+kbZ o LFkku esa LFkkiuk 'kkfey
gSA *vkiwfrZ o LFkkfir* dh njksa esa mi;qZDr milkexzh rFkk
xVj] uy o lgk;d miLdj o xVj o uyksa dh dVkbZ dk
Nhtu 'kkfey gSA
bLikr pknj ukstysa v/kksur fljksa o can fljksa dks xVj ds
lkFk >kyk tk;sxk] dks.kksa ds tksM+ Hkh >kys tk;sxsaA

(e) Nozzles, stop ends and drop ends of steel sheet gutters
shall be soldered to gutters, joints of angles shall also be
soldered.
(f) The rates also apply to where a complete run of gutter or
pipe is renewed. In minor repairs, in which a length of
gutter or rainwater pipe is necessarily cut to length, an
allowance shall be made for each cut as follows :
1
2.

M
p

When gutters or pipes are supplied by the Contractor


half metre run (supplied and fixed).
When supplied by M.D. Labour cutting only.

(g) The rates for gutters do not include for brackets.

;g njsa ogka Hkh ykxw gksxh tgka xVj ;k uy ds iwjs iFk dks
uohu fd;k x;k gSA NksVh ejEerksa esa ftuesa xVj ;k uy dh
yEckbZ dks vko';drkuqlkj yEckbZ esa dkVk xk;k gS rks izR;sd
dkV ds fy;s fuEu:i ls NwV nh tk;sxh%&
1 tc xVj ;k uyksa dh vkiwfrZ Bsdsnkj us dh gS% vk/kk
ehVj iFk vkiwfrZ o LFkkfir]
2 tc vkiwfk ,e Mh }kjk dsoy dVkbZ Je
xVj dh njksa esa czSfdV 'kkfey ugha gSaA

230

SECTION 11

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
EAVES GUTTERSSTEEL SHEET

vksyrh xVj bLIkkr pknj


PER RUNNING METRE

iz f r ehVj

Supplied & fixed

vkiwfkZ rFkk LFkkfir


Thickness of
sheet 1 mm

Thickness of
sheet 1.25 mm

Fixing only
(any dia/size)

pknj dh eksVkbZ
1 feeh

pknj dh eksVkbZ
1-25 feeh

dsoy LFkkiu
dksbZ O;kl@
vkdkj

dia
mm

dia
mm

dia
mm

dia
mm

dia
mm

dia
mm

O;kl O;kl
feeh feeh
100 125

O;kl
feeh
150

O;kl
feeh
100

O;kl
feeh
125

O;kl
feeh
150

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

11087 Mild steel sheet eaves


gutters, galvanised
class 3, half round
with rounded edges
111.00 130.20 149.10 127.80 152.10 174.30 27.20

EACH
11088 Angles (internal or
external) or nozzle
70.40 74.00 78.70
pieces (Out lets)
11089 Drop ends (for spigot
or socket ends) or
83.60 86.00 89.50

nozzles
11090 Stop
ends
(for
spigot or socket 46.70 50.20 53.70
ends)

73.40

86.00
55.70

78.70

89.50
57.20

85.70 55.00

93.00 55.00
59.50 23.20

11087
11087vksyrh xVj uje bLikr
dh pknj dh tLrh] Js.kh
3] xksy fdukjksa dh vk/kh
xksy
iz R ;s d
11088 ifV~V;ka van:uh ;k ckgjh
;k uksty [kaM fudkl

11089 v|ksur fljs dksVj ;k


lkfdV fljksa gsrq ;k uksty

11090 can fljs dksVj ;k lkdsV


gsrq

231

SECTION 11

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
RAIN WATER PIPESCAST IRON

cjlkrh ikuh uy&<yk yks g k


PER RUNNING METRE

Supplied and fixed

Fixing only
(any size)

vkiwfkZ o LFkkfir

11091 Cast iron rainwater


sock- eted pipes with
cement joints, without

ears

11092 Ditto, but with ears

dia mm

dia mm

dia mm

O;kl feeh
75

O;kl feeh
100

O;kl feeh
150

Rs.

Rs.

Rs.

dsoy LFkkiu
dksbZ izeki
Rs.

575.60

647.10

720.70

72.10

587.40

658.80

732.50

72.10

EACH
The following rates apply to
accessories with or without
ears.
11093 Offsets, projection

upto 150mm
11094 Offsets, projection exc.

150mm & up to 305mm

568.10

679.00

54.00

515.00

596.30

699.00

54.00

216.60

286.10

394.70

54.00

11097 Branch, double

356.00

493.00

587.50

85.30

490.70

630.30

712.10

93.50

11098 Heads, square type,

flat

177.40

200.90

324.30

37.60

11099 Heads, hopper type,


flat or corner

216.60

286.10

359.40

51.10

11100 Shoes

11101 Diminishing piece

240.10

315.50

394.70

51.10

11102 Wire
balloon,
galvanised steel
11103Add to items 11093 to
11096 if provided with

access (inspection) door

27.00

27.00

27.00

11104Add to items 11091 to


11101 for providing lead
joints in lieu of cement
joints for pipes embedded in masonry or con
crete

223.00

228.20

428.40

11096 Branch, single

11091 <ys yksgs ds] fcuk d.kZ lhesVa


tksM+ksa lfgr lkdsV yxs
cjlkrh ikuh ds uy
11092 mi;qZDr] fdUrq d.kZ lfgr
iz R ;s d
fuEu njsa d.kZ lfgr ;k jfgr lgk;d
oLrqvksa ij ykxw gksrh gSa
11093 [klds] mHkkj 150 feeh rd

392.00

11095 Bends or elbows,

square, or obtuse

iz f r ehVj

11094 [klds] mHkkj 150 feeh ls


vf/kd vkSj 305 feeh rd
11095 eksM+ ;k dksfu;ka] pkSdksj ;k
vf/kd dks.kh
11096 'kk[kk;sa] ,dy
11097 'kk[kk;sa] ;qxy
11098 'kh"kZ] oxZ fdLe] likV
11099 'kh"kZ] Vkaij uewuk] likV ;k
dksuh
11100 'kwt
11101 U;qud [kaM
11102 rkjh xqCcjs] tLrh bLikr
11103 tksMsa+] en 11093 ls 11096
esa ;fn igqp
a fujh{k.k }kj
dh O;oLFkk gS
11104 tksMa+s en 11091 ls 11101
es]a ;fn fpukbZ ;k dahV esa
yxs uyksa esa lhesVa tksMk+ as ds
LFkku ij dkafpr tksM+ yxs
gSa

232

SECTION 11

SECTION 11ROOF COVERING


[k.M 11& Nr vkPNknu
GUTTERSASBESTOS CEMENT
,sLcsLVl lhesaV ds xVj
Supplied and fixed

PER RUNNING METRE

iz f r ehVj

Fixing only
(any size
or type)

vkiwfkZ o LFkkiu

dsoy LFkkiu
vksth xVj
v/kZxksy xVj
dksbZ vkdkj
size mm size mm dia mm dia mm
;k uewuk
vkdkj
vkdkj O;kl feeh O;kl feeh
11105 Asbestos cement eaves
11105 vksyrh xVj ,sLoSLVl lhesVa
gutters with union feeh 125 feeh 200
152-4
228-6
ds] ;qXed ldksVj vkSj Lohd`r
sockets and joints set
tqMkoh feykos ls tksM+ tqMs
Rs.
Rs.
Rs.
Rs.
Rs.
Ogee gutters

in approved jointing

compound

Half round gutters

108.90

278.80

80.00

EACH
11106 Angles (internal or

external) or nozzle
11107 Drop ends (with spigot

or socket ends)
11108 Stop ends (for spigot

or socket ends)

185.90

266.50

100.10

199.80

242.80

127.10

124.90

159.60

71.50

Materials and labour

lkexzh o Je

Fixing only
(any size)

125mm
dia

Rs.
eted rain water pipes
156.00
with cement joints

Rs.
190.50

Rs.
238.20

Rs.
98.60

65.70

80.60

95.40

33.50

79.40

100.90

124.80

29.60

69.10
11113 Junctions, double (ditto) 102.10
11114 Add to items 1510 to
1512 if provided with
access (inspection) door 17.60

11115 Rainwater heads, pentagonal or hexagonal 199.30


45.40
11116 Shoes

101.10
145.80

127.90
183.20

43.40
64.00

23.50

27.00`

239.60

267.90

81.00

76.30

98.80

23.50

O;kl 150
feeh

EACH
11110 Bends

11111 Bends plinth, 50mm upto

150mm, offset
11112 Junctions, single (straight
or inverted, equal or

unequal)

iz f r ehVj

dsoy LFkkiu
dksbZ eki

100mm
dia

O;kl 100 O;kl 125


feeh
11109 Asbestos cement sock- feeh

150mm
dia

iz R ;s d
11106 [kaM vUn:uh ;k ckgjh
;k uksty
11107 v/k fljk nkarns kj ;k uqdhysa
fljs okys
11108 vkoa/kd fljs nkarsnkj ;k
uqdhysa fljs

cjlkrh uy ,sLosLVl lhesaV

RAINWATER PIPESASBESTOS CEMENT


PER RUNNING METRE

11109 cjlkrh ikuh ds uy ,sLosLVl lhesVa


ds lhes a V tks M + lfgr ldks V j
yxs
iz R ;s d
11110 eksM+
11111 dqlhZ eksM+ 50 feeh ls 150 feeh]
[klds
11112 laxe] ,dy lh/ks ;k eqM]s+ leku ;k
vleku
11113 laxe] ;qxy mi;qZDr
1 1114 tksM]+ a s en 1510 ls 1512 esa ;fn vfHkxeu
}kj fufj{k.k O;oLFkk lfgr gS
1 1115 ikap ;k N% Hkqth ijukyksa ds 'kh"kZ vkoj.k
f'kjL=k.k
11116 uky 'kwt

233

SECTION 11

SECTION 11 ROOF COVERING


[k.M 11 Nr vkPNknu
cjlkrh uy ,sLcsLVl lhesaV tkjh
RAINWATER PIPES-ASBESTOS CEMENT
11117 Swan-necks upto 150 mm

offset
11118 Ditto, 225mm upto 300mm,

offset

Rs.

Rs.

Rs.

Rs.

72.30

89.20

101.30

29.00

79.40

95.00

107.10

29.10

85.20
45.40
51.20

100.90
70.50
76.30

113.00
87.00
92.90

29.00
29.00
29.00

11119 Ditto, 375mm upto 600 mm,

offset
11120 Slotted vent cowl
11121 Cone cap cowl

11117 mi;qDZ r] 150 feeh rd ds galxzhok


[klds
11118 mi;qZDr] 225 feeh 300 feeh rd
ds [klds
11119 mi;qZDr] 375 feeh 600 feeh rd
ds [klds
11120 [kkafpr fuxZe dkmy vkoj.k
11121 dksuh Vksih dkmy

CUTTING PIPES AND GUTTERS


uyksa o xVjksa dh dVkbZ
These rates apply only to fixing or refixing of pipes and gutters
supplied by M.D.

;g njsa j{kk ea=ky; }kjk fn;s x;s uyksa o xVjksa ds dsoy LFkkiu
o iqu% LFkkiu ij ykxw gksrh gSA

EACH CUT
Rs.

11122 Cutting cast iron or AC pipes (any section) from 75mm to 150mm dia

27.80

11123 Dittoexc 150mm n. exc 225 mm


dia

46.30

11124 Cutting half round or ogee, sheet


iron or AC gutters 225mm to 250mm
wide (any thickness), including
drilling for gutter bolts

11122
11123
11124

17.60

izR;sd dkV
75 ls 150 feeh O;kl ds ,lh ;k <ys yksgs
ds uyksa esa dVkbZ
150 feeh ls vf/kd ysfdu 225 feeh O;kl
ls vuf/kd] mi;ZqDr
225 feeh ls 250 fdeh rd pkSMs+ yksgs dh
pknj ;k ,slh xVjksa dh xVj dkoyksa ds
ojHkkbZ Nsnksa lfgr v/kZxksy ;k vksxh dVkbZ

TAKING DOWN, EAVES GUTTERS AND RAINWATER PIPES


vksyrh xVjks rFkk ijukyksa dks m[kkM+uk
PER RUNNING METRE

Rs.

11125 Taking down eaves gutters and


rainwater pipes (any size or
pattern), including all fittings,
heads, shoes, bends, swan-necks,
etc., including cleaning or refixing
or removal to Store (measured
overall as fixed along the centre line
over fittings and accessories)

15.30

iz f r ehVj
111125 lHkh miLdjksa] vkoj.kksa] ukyksa] eksM+ksa]
galxzhokvks]a vkfn lfgr] vksyrh xVjksa rFkk
ijukyksa fdlh Hkh vkdkj ;k uewuk dks
m[kkM+uk] iqu% LFkkiu ;k HkaMkj esa igqpkus
ds fy;s lkQ djuk tSls LFkkfir gSa dsUnz
js[kk ij miLdjksa o milk/kuksa ds ij ls
lai.w kZ eki gksxh

MATERIALS (Supplied only)


lkexzh dsoy vkiwfrZ
ASBESTOS CEMENT ROOFING SHEETS AND ACCESSORIES
,sLosLVl lhesaV vkPNknu pknjsa o milk/ku
izfr oxZ ehVj
Rs.
PER SQUARE METRE
11126 6mm thick asbestos cement (AC)
corrugated or semi-corrugated

sheets, grey

173.90

11126 6 feeh eksVh] ,sLcsLVl lhesVa ,lh ygfj;k


;k v/kZygfj;k Hkwjh pknjsa

234

SECTION 11

SECTION 11 ROOF COVERING


[k.M 11 Nr vkPNknu
ASBESTOS CEMENT ROOFING SHEETS AND ACCESSORIES-Contd...
,sLcsLVl lhesaV vkPNknu pknjsa o iwjd lkexzh tkjh
EACH PIECE

Rs.

11127 AC one piece plain angular ridge

6mm thick

88.10

PER PAIR
11128 AC two-piece, adjustable, plain

wing ridge 6 mm thick

135.10

11129 Ditto, unserrated ridge for hips

146.90

11130 Ditto, serrated ridge to suit corrugated

or semi-corrugated sheets
11131 Ditto, close fitting ridge for

corrugated sheets only

141.00
158.60

EACH
11132 AC 'S' type louvre

11133 AC north light curve to suit corrugated

or semi-corrugated sheets
11134 AC apron pieces to suit corrugated

or semi-corrugated sheets
11135 AC eaves filler pieces to suit corrugated

or semi-corrugated sheets
11136 AC cowl type ventilator

11137 AC ridge finial


11138 AC curved barge board for North

light curves
PER 100 NOS.

123.40
158.60
123.40
105.70
176.20
117.50
146.90
Rs.

11139 8mm dia 100mm to 125mm long


galvanised, coach or drive screws

(without washers)

323.10

11140 8mm dia 50mm to 100mm long

ditto (ditto)

293.70

11141 8mm dia 125mm to 200mm long

hook bolts (ditto)


11142 G.I., round flat washers for 8mm

bolts or screws

411.20
70.50

11143 Embossed curved G.I. washers for

8mm bolts or screws

82.20

11144 Bitumen impregnated asbestos felt


under-washers for 8mm bolts or

screws

58.70

izR;sd [kaM
11127 ,lh ,dy [kaMh; dks.kh; dwV 6 feeh eksVh
izfr tksM+k
11128 ,lh nks [kaMh;] lek;kstud] lknk Hkqth
dwV 6 feeh eksVh
11129 mi;qDZ r] iqVB~ ksa ds fy;s fcuk nkarksa okyh dwV
11130 mi;qDZ r] ygfj;k ;k v/kZ ygfj;k pknjksa ds
mi;qZDr nkarsnkj dwV
11131 mi;qZDr] dsoy ygfj;k pknjksa ds fy;s
dM+h ca/kd dwV
iz R ;s d
11132 ,lh *S* uewusdh f>yfeysa
11133 ygfj;k ;k v/kZ ygfj;k pknjksa ds mi;qDr]
,lh mkjh izdk'k o ?kqeko
11134 ygfj;k ;k v/kZ ygfj;k pknjksa ds mi;qDr
,lh vkoj.k [kaM
11135 mi;qZDr] ,lh vksyrh iwjd [kaM
11136 ,lh dkmy fdLe ds jks'kunku
11137 ,lh dwV dy'k
11138 mkjh izdk'k oksa ds fy,] ,lh o+ ctjk
Qyd
izfr 100 la[;k
11139 8 feeh O;kl] 100 ls 125 feeh ds tLrh dksp
;k ckyu isp dkoys o ok'kj ds lkFk
11140 8 feeh O;kl] 50 ls 100 feeh mi;qZDr
mi;qZDr
11141 8 feeh O;kl] 125 ls 200 feeh ds gqd
dkoys mi;qZDr
11142 8 feeh dkoys o ispksa ds fy;s th vkbZ xksy
ok'kj
11143 8 feeh dkoys o ispksa ds fy;s th vkbZ
mRdh.kZ o ?kqekoh ok'kj
11144 8 feeh O;kl dkoys ;k ispksa ds fy;s]
rkjdksyh lalsfpr ,sLcsLVl uenk

235

SECTION 11

SECTION 11 ROOF COVERING


[k.M 11 Nr vkPNknu
MATERIALS (Supplied only)-Contd....
lkexzh dsoy vkiwfrZ tkjh ....
ROOFING TILES
vkPNknu [kijs
Rs.

PER 100 NOS.


11145 Mangalore pattern roofing tiles

11146 Ditto, ceiling tiles

1116.20
1292.50
2350.00

11147 Ditto, ridge tiles

PER 1000 NOS.


2561.50

11148 Brick tiles 40mm thick size 23cm x


11cm

izfr 100 la[;k


11145 eaxywj uewus ds vkPNknu [kijs
11146 mi;qZDr] v/k% Nr [kijs
11147 mi;qZDr] mBko [kijs

izfr 1000 la[;k


11148 bZVa Vkby 40 feeh eksVh vkdkj 23 lseh X
11 lseh

ROOFING SLABS
vkPNknu ifV;k
PER SQUARE METRE

30mm thick

izfr oxZ ehVj

50mm

30 feeh eksVh 50 feeh eksVh


11149 Sand stone roofing slabs, self-faced

Rs.
129.20

Rs
164.50

11149 Lo% :fir ckyw iRFkj dh vkPNknu ifV;k

BITUMASTIC PRODUCTS
rkjdks y h mRiknu
PER KILOGRAM

Rs.

izfr fdyksxzke

11150 Bitumen for waterproof and damp


proof treatments any grade

37.60

11150 tylg vkSj lhyu jks/ku mipkj ds fy;s]


fdlh Js.kh dk rkjdksy

PER LITRE

iz f r yhVj

11151 Bitumen primer for use in


waterproofing and damp-proofing

treatments

11151 tylg vkSj lhyu jks/ku mipkj ds iz;ksx


ds fy;s rkjdksyh vLrj
47.00

PER KILOGRAM

izfr oxZ ehVj

11152 Self-finished bitumen felt for water

proofing, glass fibre base grade 2

11152 tylg ds fy;s dkap js[kk vk/kkj Js.kh 2


dk Lor% Lkaiw.kZ rkjdksy

88.10

236

SECTION 12

SECTION 12CEILING AND LININGS


[k.M 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
SPECIAL CONDITIONS
fo'ks"k 'krsZ

12-1 eki
12.1.1 All work, unless otherwise described, shall be 12-1-1 lHkh dk;Z tc rd vU;Fkk u of.kZr gksa fo'kq) likV:i esa
measured net as flat. Work formed in circular
ekis tk;saxsA xksykdkj dh xbZ lrg i`Fkd ekih tk;saxhA
12.1

Measurements

surfaces shall be measured separately.

12.1.2 Circular cutting and waste shall be measured


separately.

12-1-2 xksykdkj dVkbZ o Nhtu i`Fkd ekis tk;saxsA

12.1.3 Supporting members like timber frame-work, etc.


and cover fillets/beading shall be measured
separately.

12-1-3 lgk;d vax tSls ydM+h ds Qjesnkj dk;Z vkfn rFkk ijh
if;ka@ xksVsa i`Fkd ekih tk;saxhA

12.1.4 No deduction shall be made for opening n exc 0.4


sq. m.

12-1-4 0-4 oxZ ehVj ls vuf/kd foojksa ds fy;s dksbZ dVkSrh ugha
gksxhA
12.2 Rates
12-2 njs a
12.2.1 The rates include for:
12-2-1 ;g njsa bUgsa 'kkfey djrh gS%&
(a) Work in ceilings, linings, panelling and/or
d v/k% Nrxhjh vLrj] fnYyscna h rFkk@;k vU; voLFkk;sa
any other location and in sizes required.
rFkk visf{kr vkdkj esaA
(b) All straight raking cutting and waste.
[k lHkh lh/kh o frjNh dVkbZ o NhtuA
(c) Fixing boards etc. as specified or as per
x visf{kr LFkkiu iV~V vkfn ;k fuekZrk dh O;oLFkkvksa
makers instructions or fixing in grooved
ds vuqlkj ;k [kkapsnkj ;k i[knkj ifjos'k esaA
rebated surroundings.

(d) Chamfering or rounding the edges of


boards etc. where directed.

?k iV~Vksa vkfn esa tgka funsZ'k gksa] frjNs ;k xksy fdukjs


fudkyukA
p iV~V vkfn dk yxkuk] fdlh fo'ks"k rjhds esa rFkk]
fdlh fo'ks"k jax ;k :i dh izkfIr ds fy;s d.k dk
lqesy ;k vuesyA
N ldjh pkSMk+ bZ;ksa esa dk;Z tc rd vU;Fkk of.kZr u gksA

(e) Fixing boards etc. to any specific pattern and


also matching or mismatching of grains to
obtain a particular design or figure.
(f) Work in narrow widths, unless otherwise
described.
(g) Mitring at junctions.

t tksMk+ sa ij HkjkbZA

12.2.2 Repair Work The rates for "Add if fixed in repairs"


will be admissible where the area of patches to be
repaired does not exceeding 3 sq.m each.
Note: New work in small quantities shall not be treated as
work in patches in repair.

12-2-2 ejEer lq/kkj dk;Z% "tksMa+s lq/kkj esa " dh njsa ogka ykxw gksx
as h
tgka lq/kkj fd;s tkus okys Hkkx 3 oeh ls vf/kd u gksaA

12.2.3 Add if fixed in ceiling rates shall be payable only


when ceiling boards, etc., are fixed from below.

12-2-3 tksMa+s *;fn v/k% Nr es*a dh njsa dsoy rHkh ns; gksx
a h tc Nr
p vkfn uhps ls yxkk;s gksaA

uksV%

NksVs ifjeki ds dk;Z *lq/kkj dk;Z isou* ugha ekus tk;saxsA

SECTION 12

237

SECTION 12CEILING AND LININGS


[k.M 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
ASBESTOS CEMENT BUILDING BOARDS
,sLcsLVl lhesaV bekjrh iV~V
PER SQUARE METRE

12001 Asbestos cement plain


building boards, fixed to
timber framework with

screws

izfr oxZ ehVj

M&L

Except
Add if fixed Add if
lkexzh ,oa Je board (any in ceiling, fixed in
thickness)
flat or
repairs
4mm 6mm iV~Vs jfgr
sloping
tksM+s ;fn
thick thick dksbZ eksVkbZ
tksM+s ;fn ejEer esa

4 feeh 6 feeh
eksVs
eksVs
Rs.

likV@<yoka
LFkkfir

Rs.

183.10 236.00

PER RUNNING METRE


12002 Asbestos cement
building board cover
strips, 50mm x 5mm,
with bevelled edges
over joints including
all mitres, etc., and

fixed with screws

Rs.

Rs.

Rs.

59.80

13.70

14.70

Materials
& labour

Except cover Add if fixed


strips
in repairs

lkexzh ,oa
Je

vkoj.k iV~Vh
jfgr

tksM+sa ;fn
ejEer esa

Rs.

Rs.

Rs.

18.00

6.30

1.20

12001
12001,sLoSLVl lhesaV ds lery
bekjrh iV~Vs ispksa ls ydM+h dh
Qjekcanh esa LFkkfir

iz f r ehVj
12002 ,sLoSLVl lhesaV ds 50 feeh x 5
feeh dh bekjrh iV~V vkoj.k
ifV~V;ka] lHkh dyeksa vkfn lfgr
tksMk+ as ds ij dVkuh fdukjksa lfgr
ispksa ls LFkkfir

INSULATION BOARDS
jks / ku Qyd

PER SQUARE METRE

M&L

lkexzh ,oa Je

Thickness in mm
12003 Fibre
insulation
boards,
ordinary
type,. and fixed to
timber frame work

with nails
12004 Ditto, flame retardant
type, treated on one
face only, ditto

dksbZ eksVkbZ

eksVkbZ feeh esa


12
Rs.

18
Rs.

izfr oxZ ehVj

Except Add if fixed Add if


board any in ceiling, fixed in
thickness
flat or
repairs
Qyd jfgr sloping tksM+s ;fn

Rs.

tksM+s ;fn ejEer esa


12003 js'ks ds jks/ku iV~V] lk/kkj.k fdLe
likV@<yoka
ds] ydM+h dh Qjekcanh esa dhyksa
LFkkfir
ls LFkkfir
Rs.
Rs.

225.10 278.20

25.40

24.50

248.60 319.30

25.40

24.50

13.20

12004 mi;ZqDr] vfXu vojks/ku fdLe


ds dsoy ,d vksj mipkfjr
13.20
Qyd mi;ZqDr

238

SECTION 12

SECTION 12CEILING AND LININGS


[k.M 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
INSULATION BOARDS Contd...
jks/ku Qyd tkjh
PER SQUARE METRE

M&L

lkexzh ,oa Je
Thickness in mm

eksVkbZ feeh esa


12005 Particle board for
i n s u l a t i o n
12
16 18/19
purposes, fixed
Rs.
Rs.
Rs.
with nails to timber
296.80 365.50 447.70

framework
12006 Ditto but except

particle board
38.80 48.70 48.70
12007 Perforated particleboard/
tiles for insula-tion and
accoustic purposes,
60x60 cm in size, fixed
with nails to timber
frameworkorwithstaples
307.60 377.20 459.50

on snap grid
12008 Ditto but except per
forated board/tiles
37.40 48.70 48.70
12009 Add if fixed with
2.30
3.10 3.10

screws
12010 Add if fixed in ceiling,

flat or sloping
26.10 34.40 34.40

25
Rs.

40
Rs.

535.90 758.00
48.70

53.50

13.70

48.70

53.50

13.70

3.10

3.60

1.30

34.40

36.40

12013 Add to item 12011, if


fixed with blown
type bitumen of grade
85/25, applied hot at
the rate of 2.25 kg/
sqm in lieu of fixing

with nails

40
Rs.

dsoy
LFkkiu
50
Rs.

75
Rs.

236.50 298.80 318.80 360.60 465.10


34.40

34.40 34.40

13.70

Fixing
only

eksVkbZ feeh esa


25
Rs.

13.70

553.50 781.60

lkexzh ,oa Je

20
Rs.

13.70

12007 fNfnzr nkusnkj] jks?ku o /ofu iz;kstu


ds 60 x 60 lseh ds] Qyd Vkby]
ydM+h dh Qjecnh ls dhyksa ls ;k
[kVdk tkyh ij dqaMksa ls LFkkfir

Thickness in mm
12011 Wood wool building
slabs, light weight,
type 1, fixed with nails

to timber framework
12012 Add if fixed in ceiling,

flat or sloping

tksMsa+ ;fn
ejEer esa 12005 jks/ku iz;kstu ds fy;s nkusnkj
LFkkfir
Qyd] ydM+h dh Qjekcanh esa
Rs.
dhyksa ls LFkkfir
12006 mi;ZDq r] fdUrq nkusnkj Qyd jfgr

M&L

PER SQUARE METRE

izfr oxZ ehVj

Add if
fixed in
repairs

34.40

Rs.

85.50

34.40

Rs.
29.60
34.40

12008 mi;qZDr] fdUrq /ofu Qyd@


Vkby jfgr
12009 tksMsa+] ;fn ispksa ls LFkkfir

12010 tksM+sa] ;fn v/k% Nr esa likV ;k


<yoka yxs gksa

izfr oxZ ehVj

12011 bekjrh ydM+h ds uewuk 1 ds


gYds Hkkj ds Nhyu Qyd] ydM+h
dh Qjescn
a h esa dhyksa ls LFkkfir
12012 tksMs+a] ;fn v/k% Nr esa likV ;k
<yoka LFkkfir gksa
12013 tksMsa+] en 12011 esa ;fn nX/k
fdLe ds 85@25 Js.kh okys
rkjdksy dk 2-2 fdxzk- izfr oeh
ds fglkc ls] dhyksa ls LFkkiu ds
LFkku ij iz;ksx fd;k gS

239

SECTION 12

SECTION 12CEILING AND LININGS


[kaM 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
MEDIUM DENSITY FIBRE BOARD
e?;e ?kuRo js ks ; q D r Qyd
(a) The rates for cover fillets include for mitres and fair end,
chamfering/rounding edges of fillets if indicated, shall be
measured separately under item 12072.

(b) The rates include for fixing cover fillets flat or curved
surface.

[k

PER SQUARE METRE

M&L

Except

lkexzh ,ao board, any


Je
thickness
Thicknes Qyd jfgr
in mm
dksbZ eksVkbZ
eksVkbZ
feeh esa
12014Medium density fibre
board, exterior grade,
fixed
to
timber
framework
with
screws

12mm

tksM+sa ;fn
cafdr ;k
o lrg

tksM+sa ;fn
ejEer esa
LFkkfir

Rs.

Rs.

Rs.

368.00

66.70

13.70

14.70

14.70

M&L
Thickness in mm

eksVkbZ feeh es

Except cover
fillets, any
thickness

vkoj.k iV~Vh
jfgr] dksbZ
eksVkbZ

4.5

Rs.

Rs.

Rs.

Rs.

13.80

8.60

11.10 12.70

izfr oxZ ehVj

Add if
fixed in
repairs

Rs.

lkexzh ,oa Je

12017 Cover fillets of


tempered
hard
board, 40mm wide
and fixing with

screws
12018 Add to each 10mm

more width

tksM+sa ;fn
likV@
<yoka
LFkkfir

Add if
bent of
curved
surfaces

Rs.

PER RUNNING METRE

12015 Cover fillets of


standard
hard
board, 40mm wide,
and fixing with

screws
12016 Add for each 10mm

more width

Add if
fixed in
ceiling,
flat or
sloping

vkoj.k if;ksa dh njksa esa dyeh ;k lkQ Nksj 'kkfey gS(


i[knkj@xksy fdukjs cukus dk fufnZ"V gS rks og en 12072
ds vUrxZr i`Fkd ekis tk;saxsA
bu njksa esa vkoj.k ifV~V;ksa dks likV ;k o lrgksa ij LFkkfir
djuk 'kkfey gSA

12014
12014e/;e ?kuRo js'ks;Dq r Qyd]
ckgjh Js.kh ispksa ls ydM+h
dh Qjekcanh esa LFkkfir

iz f r ehVj

Add if fixed
in ceiling
flat or
sloping

TkksM+sa ;fn
v/k% Nr ;k 12015 vkoj.k ifV~V;ka] ekud dBksj
Qyd dh 40 feeh pkSMh+ rFkk
<yoka LFkkfir
ispksa ls LFkkiu
Rs.

1.20

1.10

12016 tksMsa+] izR;sd 10 feeh vf/kd


pkSM+kbZ ds fy;s

12.30 13.10

14.20

12017 vkoj.k ifV~V;ka ifu;k dBksj


Qyd dh 40 feeh pkSMh+ rFkk
ispksa ls LFkkiu

0.90

1.40

0.70

0.90

1.10

8.60

1.20

12018 tksMsa+] izR;sd 10 feeh vf/kd


pkSM+kbZ ds fy;s

240

SECTION 12

SECTION 12CEILING AND LININGS


[kaM 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
HIGH PRESSURE STEAM CURED (HPSC) NON-ASBESTOS FIBRE CEMENT
REINFORCED MULTIPURPOSE BOARD
The board shall be as per IS-14862 and shall be manufactured from homogeneous mixture of cement, quartz and
cellulose and shall be cured with high pressure steam using auto claving process.
M&L

PER SQUARE METRE

Add if
fixed in
repairs

lkexzh ,oa Je
12019Non asbestos fibre
cement building
boards
fixed or
laid/ inserted to
timber/GI/Aluminium framework

with screws

Thickness in mm

4
Rs.

eksVkbZ feeh- esa


6
8
10
Rs.

Rs.

Rs.

12

16

tksM+sa ;fn
ejEer esa
LFkkfir

Rs.

Rs.

Rs.

189.40 248.10 306.90 342.10 377.40 471.40


12020Ditto except non
asbestos building
boards

60.10
12021Add if fixed in
ceiling flat or
sloping
37.20
12022Deduct if fixed with
nails
7.90
12023Add if fixed in
jointless finish
with
jointing
compound
and
jointing tape as per
manufacturer

instructions
29.40

14.70

60.10

60.10

60.10

60.10

60.10

14.70

37.20

37.20

37.20

37.20

37.20

14.70

7.90

7.90

7.90

7.90

7.90

29.40

29.40

29.40

29.40

29.40

7.90

izfr oxZ ehVj


12019
12019,LoSLVl dh txg vU;
js'ks;Dq r lhesUV bekjrh
iVVs] ispksa ls ydMh
dh@tLrh
yks g s
dh@vY;qfefu;e dh
QjekcUnh esa LFkkfir ;k
fcNk;k x;k@ tksMk x;kA
12020
12020mi;ZqDr] ,LoSLVl dh
txg vU; js'ks ;qDr
bekjrh is jfgr
12021
12021tksMs] ;fn v/k% Nr esa
likV ;k <yoka yxs gks

12022
12022?kVk;s] ;fn dhyksa es
LFkkfir gSAa
12023
12023tksMs ;fn tqMkoh feyko
vkSj tqMkoh Vsi ls fuekZrk
ds funs'Z kks ij tksM jfgr
LFkkfir gSA

PER RUNNING METRE

iz f r ehVj

12024Extra for Non asbestos fibre cement


board for external
teak wood lipping

12024 en 1612 ij vfrfjDr]


6 feeh0 eks V h Vhd
ydMh dh ckgjh fdukjh
dhyksa es LFkkfir

3.40

3.40

3.40

3.40

3.40

3.40

241

SECTION 12

SECTION 12CEILING AND LININGS


[kaM 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
DECORATIVE LAMINATES

ltkoVh iVy
The rates include for fixing laminates on flat or curved surfaces,
in any size or width.

PER SQUARE METRE

M&L

lkexzh o Je

bu njksa esa fdlh Hkh vkdkj ;k pkSM+kbZ esa iVyksa dks likV ;k
o lrgksa ij LFkkiu 'kkfey gSA
izfr oxZ ehVj

Except, Lamirate any


thickness

Thickness in mm

eksVkbZ feeh esa


12025 Decorative laminate type 1
of surface finish, colour and
pattern as approved, fixed
with approved adhesive as
per
manufacturer's

instructions

fdlh Hkh eksVkbZ


ds iVy jfgr

0.9

1.5

Rs.

Rs.

Rs.

686.80

287.30

598.70

12025
12025ifj"d`r lrg Js.kh 1 ds ltkoVh
iVy] jax o uewuk Lohd`fr vuqlkj]
Lohd`r fpifpis inkFkZ ls fuekZrk ds
fofunsZ'kksa ds vuqlkj LFkkfir

BONDED MINERAL WOOL SLABS/BLANKET

ca/kd [kfut js'ks dh ifV~V;ka@vkoj.k


PER SQUARE METRE

S&F

lkexzh o Je
12026 Bonded mineral wool
blanket slab made from
glass density 24 kg/cum
and
fixed
as
per
manufacturers instructions,

25mm thick

12027 Ditto40 mm thick

izfr oxZ ehVj

Fixing only,
any thickness

dsoy LFkkiu]
dksbZ eksVkbZ

12026
12026ca/kd [kfut js'ks ds vkoj.k dkfpar
24 fdxzk@izfr ?keh ?kuRo] rFkk fuekZrk
fofufnZ"Vksa ds vuqlkj 25 feeh eksVkbZ
esa LFkkfir

Rs.

Rs.

148.40

31.40

207.10

31.40

12027
12027mi;qZDr 40 feeh eksVk
12028
12028ca/kd [kfut js'ks dh vkoj.k if;ka
48 fdxzk@izfr ?keh iks"k.k vif'k"V
dh cuh] 25 feeh eksVkbZ esa fuekZrk ds
fofufnZ"Vksa ds vuqlkj LFkkfir

12028 Bonded mineral wool


blankets slab made from
rock, density 48 kg/cum and
fixed as per manufacturers

instructions: 25mm thick

142.50

31.40

12029 Ditto 40mm thick

201.20

31.40

12030 Add, if one side of blanket/


slab (of any thickness) is
covered with polythene

based jute hessian cloth

28.80

14.80

12031 Add, if one side of blanket/


slab (of any thickness) is
covered with 25Gx20mm

mesh G.I., wire netting

67.60

14.80

12029 mi;qZDr 40 feeh eksVk


12030tksM]+ a s ;fn vkoj.k@iV~Vh fdlh Hkh eksVkbZ
12030
dh dks ,d vksj ls iksyhFkhu vk/kkfjr
twV ds gSlu diM+s ls <dk x;k gks
12031
12031tksMs+a ;fn vkoj.k@iV~Vh fdlh Hkh
eksVkbZ dh dh ,d vksj dks 25th X
25 feeh tLrh yksgs dh rkj tkyh ls
<dk x;k gks

242

SECTION 12

SECTION 12CEILING AND LININGS


[kaM 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
PLYWOOD ijrh ydM+h IykbZ
M&L

PER SQUARE METRE

lkexzh ,oa Je
Thickness in mm

eksVkbZ feeh esa


6
9
12
No. of ply
ijr la[;k
4
12032 Plywood, grade BWR,
type BB, fixed with
screws to timber frame
work
12033 Plywood, grade BWP,
type BB fixed with
screws to timber frame

work
12034 Veneered decorative
plywood, grade 1
(with BWR resin) with
decorative face veneers
on both faces; fixed
with screws to timber

frame work
12035 Deduct from item 12034
if only one face has
decorative veneer

Rs.

Rs.

Rs.

Rs.

270.70 371.10 429.80 488.60

izfr oxZ ehVj

Except
Plywood
any thickness

ijrh jfgr
dksbZ eksVkbZ

12032
12032ijrh ydM+h] BWR Js.kh] BB uewuk]
ydM+h dh Qjescna h esa ispksa ls LFkkfir

Rs.

38.50

12033
12033ijrh ydM+h] BWP Js.kh] BB uewuk]
ydM+h dh Qjescna h esa ispksa ls LFkkfir
305.30 404.00 468.60 533.20

38.50

12034
12034ijrnkj ltkoVh ijrh ydMh] Js.kh
1 ch MC;q vkj jky ls nksuksa vksj
ltkoVh ijr ;qDr] ydM+h dh
Qjescanh esa ispksa ls LFkkfir
408.40

514.20 578.80 643.40

70.50

70.50

70.50

PER SQUARE METRE

38.90

70.50

izfr oxZ ehVj

Rs.

12036 Deduct if fixed with nails


12037 Add if fixed with brass screws and cups

8.90
27.50

12038 Add if fixed in ceiling, flat or sloping

28.00

12039 Add if 4mm or 6mm plywood is bent to


circular surfaces

9.80

12040 Add if fixed in repairs

13.70
PARTICLE BOARDS

12036
12037
12038
12039

?kVk;sa] ;fn dhyksa ls LFkkfir


tksM+sa] ;fn ihry ds ispksa o Vksfi;ksa lsa LFkkfir
tksM+sa] ;fn v/k% Nr esa likV ;k <yoka LFkkfir
tksMsa+] ;fn 4 feeh ;k 6 feeh ijrh ydM+h
xksykdkj lrgksa ij >qdkbZ xbZ gksa
12040 tksMsa+] ;fn lq/kkj esa LFkkiuk
nkusnkj Qyd

M&L lkexzh ,oa Je


12041 Particle board, medium
Thickness in mm
density, flat pressed,
eksVkbZ feeh esa
single layer type or three
9
12
16 18/19
25
layer type with BWR
type adhesive, fixed Rs.
Rs.
Rs.
Rs.
Rs.
with screws to timber
261.40 296.50 365.60 395.00 497.20

frame work
12042 Add if fixed in ceiling,

flat or sloping
31.60

12035
12035?kVk;sa] en 12034 esa ls ;fn dsoy
,d vkSj ltkoVh ijr gS

31.60

36.50

36.50

41.50

Add if
fixed in
repairs
Rs.
13.70

13.70

12041
12041nkusnkj Qyd( e/;e ?kuRo
likV laihfMr] ,dy ijr
fdLe ds ;k BWR /kkrq nzO; ds
lkFk rhu ijr fdLe ds( ydM+h
dh Qjekcanh esa LFkkfir

12042
12042tksM]+as ;fn v?k% Nr esa likV ;k
<yoka LFkkfir gksa

243

SECTION 12

SECTION 12CEILING AND LININGS


[kaM 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
PARTICLE BOARDS Contd...

nkusnkj Qyd tkjh


lkexzh ,oa Je

M&L

Add if
fixed in
repairs

Thickness in mm
12043 Add if fixed in pelmet
boxes or in narrow
widths n. exc l5cm each,
rebated or flat edged

eksVkbZ feeh esa

tksM+s ;fn
12043tksMsa+] ;fn isyesV cDlksa ;k 15
ejEer esa 12043
LFkkfir
lseh izR;sd ls vuf/kd rax
pkSMkbZ;ksa esa i[knkj ;k likV
Rs.
fdukjs esa LFkkfir
13.70
12044
12044dsoy nkusnkj Qyd LFkkiu

12

16

18/19

25

Rs.
29.10

Rs.
29.10

Rs.
37.90

Rs.
37.90

Rs.
43.70

12044 Fixing only particle


39.10
boards
12045 Deduct if fixed with
9.40
nails

39.10

39.10

49.40

49.40

13.70

9.40

9.40

9.40

9.40

13.70

PER SQUARE METRE

12045
12045?kVk;sa ;fn dhyksa ls LFkkfir

PRELAMINATED PARTICLE BOARDS

iw o Z i jrd` r nkus n kj Qyd


M&L lkexzh ,oa Je
Thickness in mm

izfr oxZ ehVj

Add if fixed
in repairs

12046 Prelaminated particle


board, interior grade,
prelaminated one
side with decorative
9
choice lamination &
other side balancing Rs.
white lamination,
fixed with screws to
402.30
timber frame work
12047 Ditto but prelaminated
both sides with
decorative choice
449.30
laminations

12046 iwoiZ jrd`r nkusnkj Qyd


vkUrfjd Js.kh] ,d vksj
eksVkbZ feeh esa
tksaM+s ;fn ejEer
ltkoVh ilUn dh
12
18/19
25
esa LFkkfir
iwoiZ jrd`r ijr cUnh o
Rs.
Rs.
Rs.
Rs.
nwljh vksj lQsn lUrqfyr
ijr cUnh ydM+h dh Qjek
cUnh esa ispksa ls LFkkfir
443.40
530.10 659.30
13.70
12047 mi;qDZ r fdUrq nksuksa vksj
iw o Z i jrd` r ] ltkoVh
ilUn dh ijrcUnhA

12048 Prelaminated particle


board, exterior grade,
prelaminated one
side with decorative
choice lamination &
other side balancing
white lamination,
fixed with screws to
449.30
timber frame work
12049 Ditto
but
prelaminated both
sides with decorative
choice laminations 496.20
12050 Add if fixed in ceiling,

flat or sloping
32.00

13.70

12048 iwoZ ijr nkusnkj Qyd


vkUrfjd Js.kh] ,d vksj
ltkoVh ilUn dh
iwoZijrd`r ijrcUnh o
nwljh vksj lQsn lUrqfyr
ijrcUnh ydMh dh Qjek
cUnh esa ispksa ls LFkkfir

13.70

12049 mi;qZDr fdUrq nksuks vksj


iw o Z i jrd` r ltkoVh
ilUn dh ijr cUnh

13.70

12050 tksMs] ;fn v/k% Nrksa esa


likV ;k <yoka LFkkfir

496.20

566.70

602.00

32.00

588.80 718.10

588.80 753.30

682.80 823.80

32.00

41.90

13.70

244

SECTION 12

SECTION 12CEILING AND LININGS


[kaM 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
PRELAMINATED PARTICLE BOARDS Contd...

iwoZijrd`r nkusnkj Qyd tkjh


12051 Add if fixed in
pelmet boxes or in
narrow widths n exc
15cm each, rebated or

flat edged
12052 Fixing
only
prelaminated

particle boards
12053 Deduct if fixed with

nails

12051

Table contd...
Rs.

Rs.

Rs.

Rs.

Rs.

29.10

37.90

37.90

37.90

13.70

39.10

39.10

49.40

49.40

9.80

9.80

9.80

9.80

tksM]s ;fn isyesV cDlksa


;k 15 lseh izR;sd
vuf/kd rax pkSMkb;ksa
esa i[knkj ;k likV
fdukjksa esa LFkkfir
12052 dsoy LFkkiu] iwoZ ijr
d`r nkusnkj Qyd

12053

/kVk;sa] ;fn dhyksa ls


LFkkfir

BLOCK BOARDS AND VENEERED PARTICLE BOARDS

[kaMd Qyd rFkk iuhjs nkusnkj Qyd


M&L lkexzh ,oa Je
Thickness in mm

izfr oxZ ehVj


12054Block boards, grade 2
12054
12054[kaMd Qyd] {kerk Js.kh
eksVkbZ feeh esa
tksaM+s ;fn ejEer
quality, i n t e r i o r
2] vkUrfjd Js . kh
grade,
commercial
12
18/19
25
30
35
esa LFkkfir
O;olkf;d fdLe ds
type,
fixed with
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
ydM+h dh Qjekcanh es
screws to timber
480.20
702.60
808.30
920.50
985.20
13.70
ispksa ls LFkkfir

frame-work
12055Block boards, grade 2
12055
12055[kaMd Qyd {kerk Js.kh
quality, i n t e r i o r
2] vkUrfjd Js.kh ,d rjQ
grade, decorative type
ls ltkoVh ijr ltkoVh
with decorative face
fdLe ds] mi;qZDr
veneer on one face,
PER SQUARE METRE

562.50
Ditto
12056Ditto with decorative
face veneer on both

faces, Ditto
644.70
12057Block boards, grade 1
quality, e x t e r i o r
grade,
commercial
type,
fixed
with
screws to timber
521.30

frame-work
12058Block boards, grade 1
quality,
exterior
grade, decorative type
with decorative face
veneer on one face,
774.00

Ditto
12059 All as item 12058, but
with decorative face
veneer on both faces,
897.30
Ditto

784.80 890.60 1002.80 1067.40

Add if fixed
in repairs

13.70

867.10 972.80 1085.00 1149.70

13.70

745.00 862.50 999.30 1061.50

13.70

862.50 988.20 1126.20 1188.40

13.70

998.70 1125.60 1251.50 1315.30

13.70

12056
12056mi;qZDr] nksuksa vksj ls
ltkoVh ijr okys ]
mi;qZDr
12057
12057[kaMd Qyd] {kerk Js.kh
1] ckj Js.kh O;kolkf;d
fdLe ds ] ydM+ h dh
Qjescna h esa ispksa ls LFkkfir

12058
12058[kaMd Qyd] {kerk Js.kh
1] ck Js.kh] ,d vksj
ltkoVh eq[k ijr okys
ltkoVh fdLe ds ]
mi;qZDr
12059
12059lHkh en 12058 tSlk
fdUrq nksuksa vksj ltkoVh
eq[k ijr

245

SECTION 12

SECTION 12CEILING AND LININGS


[kaM 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
BLOCK BOARDS AND VENEERED PARTICLE BOARDS Contd...

[kaMd Qyd rFkk iuhjs nkusnkj Qyd tkjh


PER SQUARE METRE

Table contd...
Rs.

Rs.

Rs.

Rs.

Rs.

12060 Veneered
particle
boards interior grade,
solid core, general
purposes type, with
face veneers of type
'BB',
fixed with
screws to timber
392.10 479.30 608.60 709.00 797.20
frame work
12061 All as in item 12060
462.60 561.00 702.00 814.30 925.90
but exterior grade
12062 Fixing only veneered
particle board or

block board
12063 Add to items 12060 if
faced with decorative

veneer on one face


12064 Add to items 12060 if
faced with decorative

veneer on one face


12065 Add to items 12060 if
faced with decorative

veneer on both faces


12066 Add to items 12060 if
faced with decorative

veneer on both faces


12067 Add if fixed in
pelmet boxes or in
narrow width n exc
15cm each, rebated or
flat edged
12068 Deduct if fixed with
nails
12069 Add if fixed in ceiling

flat or sloping

40.10

70.50

41.10

70.50

50.50

70.50

41.10

70.50

50.50

70.50

41.10

70.50

51.00

70.50

41.10

70.50

51.00

70.50

41.10

70.50

Rs.

13.70

13.70

12061
12061lHkh en 12060 tSlk fdUrq
ok Js.kh

13.70

12062
12062dsoy LFkkiu] iuhjh nkusnkj
Qyd ;k c) Qyd

12063
12063tksMs+a] en 12060 esa ;fn
,d eq[k ltkoVh iuhjh gks

70.50

70.50

70.50

70.50

70.50

37.90

37.90

37.90

8.20

8.20

8.20

37.70

37.70

37.70

37.70

37.70

5.90

8.20

10.60

PER RUNNING METRE


12070 Extra over rates of
block board or
veneered particle
board for external
teak wood lipping,
6mm thick fixed with

nails

izfr oxZ ehVj


12060
12060iuhjh nkus n kj Qyd]
vkUrfjd Js.kh Bksl lkekU;
iz;kstuh;] *ch ch* fdLe dh
ijr lfgr] ydM+h dh
Qjekcanh esa ispksa ls LFkkfir

12064 tksMs+a] en 12060 esa ;fn


,d vksj ls iuhjh ijr gks
12065
12065tksMs+a] en 12060 esa ;fn
nksuksa vksj ls iuhjh ijr gks
12066 tksMsa+] en 12060 esa ;fn
nksuksa vksj ls iuhjh ijr
yxh gks
12067
12067tksM]as+ ;fn isyesVa cDlksa ;k
15 lseh izR;sd vuf/kd rax
pkSMkbZ;ksa esa i[knkj ;k likV
fdukjksa esa LFkkfir
12068
12068?kVk;s]a ;fn dhyksa ls LFkkfir
12069 tksM+sa] ;fn v/k% Nrksa esa
likV ;k <yoka LFkkfir
iz f r ehVj
12070
12070vfrfjDr] o Qyd ;k
iukjh nkusnkj Qyd ij 6
feeh eksVh lkxkSu dh ydM+h
dk vLrj dhyksa ls yxkus
gsrq

246

SECTION 12

SECTION 12CEILING AND LININGS


[kaM 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
CIRCULAR CUTTING TO BOARDS, ETC.

Qydksa vkfn fd xksykdkj dVkbZ


The rates apply to all kinds of insulation boards, particle boards,
block boards, asbestos cement boards hard boards and plywood
except where otherwise stated.
PER RUNNING METRE

;g njs]a tc rd vU;Fkk u dgk x;k gks] lHkh izdkj ds jks/ku Qyd]


nkusnkj Qyd] c) Qyd] ,sLosLVl lhesaV Qyd] dBksj Qyd
rFkk ijrh ydM+h Qydksa ij ykxw gksrh gSaA
iz f r ehVj

Thickness of board

Qydksa dh eksVkbZ
N exc. 5 Exc. 5
Exc. 15
mm mm but n mm but n
5 feeh
exc.
exc.
vuf/kd 15mm
30mm

Exc. 30mm Exc. 50


but n exc. mm but n
50mm
exc.
30 feeh ls 75mm

5 feeh ls 15 feeh ls
vf/kd o
vf/kd o
15 feeh
30 feeh
ls vuf/kd ls vuf/kd

vf/kd o 50 feeh ls
50 feeh
vf/kd o
ls vuf/kd 75 feeh
ls vuf/kd

12071Circular cutting to

boards and waste

Rs.

Rs.

Rs.

Rs.

Rs.

8.80

13.30

17.30

21.70

25.20

PER RUNNING METRE

12072Chamfering or rounding

edges of boards

Hard board and


Asbestos cement
boards

Insulation boards
and Particle
boards

dBksj cksMZ o ,sLcsLVl


lhesaV Qyd

jks/ku o nkusnkj
Qyd

Rs.

Rs.

3.50

2.90

12071
12071Qydksa dh xksy dVkbZ rFkk
Nhtu

iz f r ehVj

12072
12072Qydksa ds fdukjs dh i[knkj ;k
xksykdkj dVkbZ

CUTTING HOLES

Nsn dVkbZ
(a) Nothing extra shall be paid for square holes, each exc 0.1
sqm but for circular holes each exc. 0.1 sq m circular cutting
and waste shall be measured separately under item 12071.

(b) The rates apply to all kinds of boards, insulation, particle,


block and asbestos cement and plywood except where
otherwise stated.

[k

izR;sd 0-1 oeh ls vf/kd ds pkSdksj Nsnksa ij dqN Hkh vfrfjDr


ns; ugha gksxk fdUrq 0-1 oeh ls cMs+ izR;sd xksykdkj Nsnksa dh
xksy dVkbZ o Nhtu dks i`Fkd] en 12071 ds vUrxZr ekik
tk;sxkA
;g njs]a flok; tgka foijhr dgk x;k gks] lHkh izdkj ds] jks/ku]
nkusnkj c) o ,SLosLVl lhesaV ,oa ijrh ydM+h ds Qydksa
ij ykxw gksrh gSaA

247

SECTION 12

SECTION 12CEILING AND LININGS


[kaM 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
CUTTING HOLES Contd...

Nsn dVkbZ tkjh


PER 100 NOS.

izfr 100 la[;k

Area of holes, etc..., (measured net) in sq. cm

Nsn vkfn dk {ks=Qy fokq eki olseh esa


N exc.
100

Exc. 100
but in
exc. 225

Exc. 225
but n
exc. 400

100 ls vf/kd
o 225 ls
vuf/kd

225 ls vf/kd
o 400 ls
vuf/kd

Rs.

Rs.

Rs.

23.30

29.10

35.00

100 ls
vuf/kd
12073Cutting holes, square
or circular n exc. 0.1 sq.
m in any of the
foregoing boards,

sheets or tiles

Exc. 400
but n exc.
1000

400 ls vf/kd
o 1000 ls 1273 0-1 oeh vuf/kd dh Nsn
vuf/kd
dVkbZ] pkSdksj ;k xksy ij
Rs.
dgs x;s fdlh Hkh Qyd]

pknj ;k Vkby esa


46.60
12074

TEXTILE SURFACES

12074

eksVs diM+s dh lrgsa


Except cloth
Dungree or
hession

Add if
fixed in
repairs

diM+k jfgr
Max
w jh diMk Hkwjk gSlu diM+k Mawxjh ;k gSlu
12075Textile ceilings or
diMk

tksaM+sa ;fn
ejEer esa

PER SQUARE METRE

Material and Labour

lkexzh ,oa Je
Dungree
cloth, grey

linings, fixed to timber frame work with

nails
12076Ditto, but fixed to
separate
frames
frames fixed in position with screws
(frames
measured

separately)

Hessian
cloth

Rs.

Rs.

Rs.

Rs.

75.70

46.20

29.10

14.00

izfr oxZ ehVj

12075
12075diMas+ dk Hkhrjh vkPNknku
;k vLrj] ydM+ h dh
a h eas dhyksa ls LFkkfir
Qjescn
12076
12076mi;qZDr] fdUrq i`Fkd Qjeksa
;k LFkkiu esa yxs Qjeksa esa
ispksa ls LFkkfir Qjes i`Fkd
ekis tk;sxsa

91.70

60.90

42.70

14.00

REED WALLING

ljda M h nhokjxhjh
(a) Reed walling shall be measured net i.e. portion housed into
grooves of timber framing shall not be measured.

(b) Plastering and timber frame work shall be measured


separately.

[k

ljdaMh nhokj fo'kq) ekih tk;sxh vFkkZr~ ydM+h dh Qjescna h


ds [kkapksa esa x;k gqvk Hkkx ugha ekik tk;sxkA
iyLrj rFkk ydM+h dh Qjekcanh i`Fkd ekih tk;sxhA

248

SECTION 12

SECTION 12CEILING AND LININGS


[kaM 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
REED WALLING Contd...

ljdaMh nhokjxhjh tkjh


PER SQUARE METRE
12077Single reed walling, stiffened by means
of doubled bamboo slips 25 mm wide
and not less than 6mm thick (one slip
on each side of reed walling) at right
angles and not more than 40 cm apart,
tied together with cane slips and by
tying with 0.90mm, black wire at 45 cm

to 50 cm centres

Materials and
Labour

Lkkexzh o Je

Rs

24.00

12078Double reed walling each wall lining


stiffened by means of double bamboo
slips and tied together as described in

item 12077

48.00

izfr oxZ ehVj


12077
12077bdgjh ljdaMh nhokjxhjh] ftls 25 feeh
pkSM+h o de ls de 6 feeh eksVh ckl dh
[kifPp;ksa ls ledks.k ij dlk x;k ljdaMh
nhokj izR;sd vksj ,d [kiPph rFkk 40 lseh
ls vuf/kd Qklys ij cSar dh ifV~V;ksa ls
cka/kk x;k gks ,oa 45 ls 50 lseh ds Qklys ij
0-90 feeh ds dkys rkj ls nksuksa dks lkFk
cka/kk x;k gks
12078
12078nksgjh ljdaMh nhokjxhjh] izR;sd nhokj vLrj.k
nksgjh ckal [kifPp;ksa ls dlk x;k rFkk nksuksa
dks en 12077 esa of.kZr <ax ls ck/kk x;k

PLASTER OF PARIS CEILING

iS f jl iYkLrj xp vkPNknu
PER SQUARE METRE

Material and
labour
12079 Providing and fixing 10mm thick

12080
12081
12082

12083
12084

12085

plaster of paris ceiling (Gypsum


anhydrous) to flat surface over 2nd
class soft wood fillets, or metal frame
work and reinforced with G.I. wire
mesh (Fillets, metal frame work and
G.I. wire mesh paid separately)

Ditto-but to curved surface


Extra over item 12079 & 12080 for
any sunk or raised moulding
Providing and fixing Gypsum
Board 12mm thick in ceiling fixed
with screw as per manufacturers

instructions

Ditto, but in walling


Seamless calcium silicate ceiling made
out of 1800 x 1200 mm size board of
siliceous and calcareous material
reinforced with cellulose fibre fixed to
the ceiling section with 25 mm long
self drilling and tapping screws
having phillips head with under head
cutter at 200 mm centre to centre,
including finshing the joint of face
board with specially formulated
jointing compound and 48 mm wide
fibre tape to provide seam less finish
(Frame work for ceiling shall be
measured and paid separately)
Exposed metal frame ceiling with
calcium silicate board of siliceous
and calcareous material reinforced
with cellulose fibre for fixing in 600
mm x 600mm grid (Frame work for
ceiling shall be measured and paid

separately)

lkexzh ,oa Je

Except
Material

izfr oxZ ehVj

2079
lkexzh jfgr 1 910 feeh eksVs iSfjl iyLrj dh O;oLFkk

Rs.

Rs.

266.70
322.80

145.90
202.10

121.20

90.70

223.50
210.80

64.90
52.20
M&L

8 mm

12 mm

312.20
6 mm

370.90
8 mm

215.70

262.70

djuk rFkk mls f}rh; Js.kh dh uje ydM+h


dh ifV~V;ksa rFkk tLrh yksgs dh rkjtkyh ls
fojfpr likV lrg ij LFkkiu djuk
if;ka o rkjtkyh i`Fkd ns; gksaxh
1 2 0 8 00mi;qZDr] fdUrq o lrg ij
1 2 0 8 11vfrfjDr] en 12079 o 12080 ij /kals gq;s
;k mHkjs <kapksa gsrq
1 2 0 8 2212 feeh eksVs ftIle Qyd dh O;oLFkk rFkk
fuekZrk ds fofufnZ"Vksa ds vuqlkj ispksa ls v/k%
Nr esa LFkkfir
12083 mi;qZDr] fdUrq nhokjxhjh esa

249

SECTION 12

SECTION 12CEILING AND LININGS


[k.M 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
MATERIALS (Supplied only)
lkexzh dsoy vkiwfrZ
PER SQUARE METRE

izfr oxZ ehVj

Thickness in mm

eksVkbZ feeh esa


12086 Asbestos cement building boards,

plain

4
Rs.

6
Rs.

123.40

176.30

12086 ,sLoSLVl lhesaV bekjrh Qyd] likV


iz f r ehVj
12087 50 feeh x 5 feeh ds izo.ku dksjnkj
fdukjksa okyh ,sLoSLVl lhesaV dh vkoj.k
if;ka

Rs.

PER RUNNING METRE


12087 50mm x 5mm asbestos cement cover

strips with bevelled edges

11.70

izfr oxZ ehVj

Thickness in mm
PER SQUARE METRE

eksVkbZ feeh esa

12088 Fibre insulation boards, ordinary

type
12089 Ditto, Flame retardant type, treated

on one face only

12
Rs.
200.00

18
Rs.
252.60

229.10

293.70

PER SQUARE METRE

12088 js'ksnkj jks/ku Qyd lkekU; fdLe ds


12089 mi;qZDr] vfXu vojks/kd fdLe ds] dsoy
,d vksj mipkfjr

izfr oxZ ehVj

Thickness in mm

eksVkbZ feeh esa


12
12090 Particle boards for insulation

purposes
12091 Perforated particle boards or
tiles for insulation and
accoustic purposes, 60cm x

60cm in size

16

18/19

25

Rs.
258.50

Rs.
Rs.
Rs.
317.30 399.50 487.60

270.30

329.00 411.30 505.30

12090 nkusnkj Qyd] jks/ku iz;kstu gsrq


12091 eqyEek;qDr fNfnzr nkusnkj Qyd
;k Vkbys]a jks/ku o /ofu iz;kstukFkZ
vkdkj 60lseh x 60lseh

Thickness in mm

eksVkbZ feeh esa


20
12092 Wood-wool building slabs.

light weight, type I

25

40

50

75

Rs.
Rs.
Rs.
Rs.
Rs. 12092
208.00 270.30 290.20 323.10 428.90

gYds Hkkj ds Nhyu Qyd uewuk&1

250

SECTION 12

SECTION 12CEILING AND LININGS


[k.M 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
MATERIALS (Supplied only)-Contd...
lkexzh dsoy vkiwfrZ tkjh
PER SQUARE METRE

izfr oxZ ehVj

Thickness in mm

eksVkbZ feeh esa


0.9
Rs.
311.40

12093 Decorative laminates type I, or surface


finish, colour and pattern as approved

1.5
Rs.
399.50

12093 ltkoVh Qyd uewuk 1] ;k ifj"d`r lrg jax


o :i Lohd`fr vuqlkj

PLYWOOD
ijrh ydM+ h
PER SQUARE METRE

Thickness in mm

izfr oxZ ehVj

eksVkbZ feeh esa


4

6
No. of ply

3
Rs.
12094 Plywood grade BWR, type BB
12095 Plywood grade CWR, type BB
12096 Veneered decorative ply wood,
grade I (with BWR resin)
decorative veneers on both faces

12097 Ditto.on one face only

5
Rs.

12

ijr la[;k
5
Rs.

7
Rs.

263.20 361.90 426.50 491.10


235.00 329.00 387.70 446.50

364.30 470.00 534.60 599.30


293.70 399.50 464.10 528.70

12094 ijrh IykbZ ydM+h] Js.kh BWR, uewuk ch ch


12095 ijrh ydM+h] Js.kh CWR, uewuk ch ch
12096 ijrnkj ltkoVh ijrh ydM+h] Js.kh 1 BWR
jsftu lfgr nksuksa vksj ltkoVh ijr
12097 mi;qZDr] dsoy ,d eq[k ij

PARTICLE BOARDS
nkus n kj Qyd

Thickness in mm

PER SQUARE METRE


12098 Particle board, medium
density, flat pressed, single
layer type or three layer type,
BWR grade

izfr oxZ ehVj

eksVkbZ feeh esa


9

12

16

18/19

25

Rs.

Rs.

Rs.

Rs.

Rs.

12098 nkusnkj Qyd] e/;e ?kuRo] likV


laihfMr bdgjh ijr fdLe ;k rhu
223.30 258.50 317.30 346.60 448.90
ijrnkj] BWR Js.kh

251

SECTION 12

SECTION 12CEILING AND LININGS


[k.M 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
MATERIALS (Supplied only)-Contd...
lkexzh dsoy vkiwfrZ tkjh
BLOCK BOARDS AND VENEERED PARTICLE BOARDS
[kaMd Qyd rFkk iuhjh nkusnkj Qyd
PER SQUARE METRE

izfr oxZ ehVj


Thickness in mm

eksVkbZ feeh esa


12099 Block board, grade 2 quality,
interior grade, commercial

type

12
Rs.

18/19
Rs.

25
Rs.

30
Rs.

40
Rs.

12099 [kaMd Qyd] Js.kh 2 {kerk]


vkUrfjd Js.kh O;kolkf;d fdLe

440.60 652.10 757.90 869.50 934.10

12100 Ditto, decorative type, one 552.90 734.40 840.10 951.70 1016.40

face
12101 Ditto, decorative type, both
605.10 816.60 922.40 1034.00 1098.60
faces
12102 Block board, grade 1 quality,
exterior grade, commercial
481.70 705.00 822.50 948.20 1010.50
type

12100 mi;qZDr] ,d vksj ls ltkoVh


fdLe ds
12101 mi;qZDr] nksuksa vksj ls ltkoVh
fdLe ds
12102 [kaMd Qyd Js.kh 1 {kerk] ok
Js.kh O;kolkf;d fdLe ds

12103 Ditto, decorative type, one


734.40 822.50 948.20 1075.10 1137.40
face
12104 Ditto, decorative type, both
857.70 948.20 1075.10 1200.90 1264.30
faces

12103

12105 Veneered particle board,


interior grade, solid core,
medium density general
purposes type with commercial

face veneers type 'BB'

12106 Ditto, exterior grade


12107 Veneered particle board, solid
core, interior grade, with
decorative face veneers one face

12108 Ditto, with decorative face

veneers both faces

12105

352.50 428.90 558.10 658.00 746.10


423.00 511.10 652.10 763.70 875.40

387.70 464.10 593.40 693.30 781.40

12104

12106
12107

12108

423.00 499.40 628.60 728.50 816.60

12109 Veneered particle board, solid


core, exterior grade, with
decorative face veneers one face
464.10 552.30 693.30 804.90 916.50

12110 Ditto,with decorative face


499.40 587.50 728.50 840.10 951.70
veneers both faces
12111 Medium density fibre board
305.50
exterior grade
12112 Gypsum board for ceiling/
158.60
walling

12109

mi;qZDr] ,d vksj ls ltkoVh


fdLe ds
mi;qZDr] nksuksa vksj ls ltkoVh
fdLe ds
iuhjh nkusnkj Qyd] vkUrfjd
Js.kh] Bksl ksM] e/;e ?kuRo lkekU;
iz;kstuh;] O;kolkf;d *ch ch* fdLe
ds iuhjh psgjs lfgr
mi;qZDr] ok Js.kh
iuhjh nkusnkj Qyd] Bksl ksM]
vkUrfjd Js.kh] ,d vksj psgjs ls
iuhjh ltkoV
mi;qZDr] nksuksa vksj psgjs ls iuhjh
ltkoV
iuhjs nkusnkj Qyd Bksl ksM ok
Js.kh ,d vksj psgjs ls iuhjh ltkoV

12110 mi;qZDr] nksuksa vksj psgjs ls iuhjh


ltkoV
12111 e/;e Js.kh ds js'ksnkj] Qyd ok
Js.kh ds
12112 ftIle Qyd] v/k% Nr] nhokjksa ds
fy;s

252

SECTION 12

SECTION 12CEILING AND LININGS


[k.M 12&Hkhrjh Nr vkPNknu rFkk vLrj.k
MATERIALS (Supplied only)-Contd...
lkexzh dsoy vkiwfrZ tkjh
BONDED MINERAL WOOL BLANKET/SLAB
ca / kd [kfut js ' ks n kj vkoj.k@ih
PER SQUARE METRE
12113 Bonded mineral wool blanket/
slab made from glass, density 24 kg/

cu m
12114 Bonded mineral wool blanket/slab
made from rock slag density 48 kg/

cu m

25mm thick

40mm thick

25 feeh eksVk

40 feeh eksVk

Rs.
117.50

Rs.
176.30

111.60

170.40

izfr oxZ ehVj


12113
12113ca/kd [kfut js'ksnkj vkoj.k@if;ka
dkafpr] ?kuRo 24 fdxzk@izfr ?keh
12114 ca/kd [kfut js'ksnkj vkoj.k@if;ka] iks"kk.k
vif'k"V ls cuh ?kuRo 48 fdxzk@?keh

TEXTILES
cqus eksVs diM+sa
PER SQUARE METRE

izfr oxZ ehVj

Rs.

12115 Dungree cloth, grey, 330 g/ sq. m

12116 Hessian No I, 11 porter. 12 shot (coloured)

47.00
17.60

12115 Hkwjk Mwx


a jh diM+k] 330 xzke@izfr oxZ ehVj
12116 gSlu ua- 1] 11 iYys 12 /kkjh jaxfojaxk
izfr fdyksxzke

PER KILOGRAM
38.20

12117 Blown bitumen of any grade

12117 Qqadk fdlh Js.kh dk rkjdksy

PRELAMINATED BOARDS
PER SQUARE METRE
9mm
12118 Pre laminated interior grade

one side laminated


12119 Pre laminated interior grade

both sides laminated


12120 Pre laminated exterior grade

one side laminated board


12121 Pre laminated exterior grade
both side laminated board

12mm 19/20mm 25mm

364.20

405.40

481.70

611.00

411.30

458.30

540.50

669.70

411.30

528.70

564.00

705.00

458.30

564.00

634.50

775.50

253

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
SECTION 13
FLOOR FINISHES AND PAVINGS
[k.M 13 Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
SPECIAL CONDITIONS
fo'ks"k 'krsZ
13.1 Measurements
(a) No deduction shall be made for voids not
exceeding 0.2 sq.m each.
(b) Deduction for ends of dissimilar materials or
other articles embedded shall not be made for
areas not exceeding 0.1 sq.m each.

13-1 eki
d izR;sd 0-2 o eh- ls vuf/kd f>fj;ksa dh dVkSrh ugha dh tk;sxh

[k fo"ke lkexzh ds fdukjksa ;k vU; fcNkbZ xbZ cLrqvksa dh dVkSrh


ugha dh tk;sxh] ftudk izR;sd dk {ks= 0-1 o-eh- ls vf/kd ugha
gSA
(c) The area of flooring shall be measured excluding x Q'kZ dk {ks=Qy] izlkj tksM VwVs [kaM+ks dks NksM+dj ekik
expansion joints and crumple sections.
tk;sxkA
13-2 njsa
d Q'kZ dh njksa esa fuEu lfEefyr gSa%
1 vfuR; Hkjko] fdukjksa dh cukbZ] dVko] eksM]+ lh/ks fdukjksa
vkfn esa f?klkbZ vkSj NhtuA
(2) Preparation of the sub-grade, sub-base, base
2 v/kLrj] v/k vk/kkj] vk/kkj] v/k Q'kZ fuEu }kjk fufeZr%&

13.2 Rates

(a) The rates for flooring include for:


(l) Use and waste of all temporary fillets, side
forms, templets, moulds, straight edges etc.
or sub-floor by:(i) Removing slight undulations of the
ground or made up base by trimming or
filling up with approved materials.
(ii) Cleaning and watering (if directed) the
surface immediately before laying the
sub-base, base, sub-floor or floor finish.

i Hkwfe dh vlekurk nwj djuk ;k dkaV&NkaV }kjk


vk/kkj cukuk ;k Lohd`r lkexzh }kjk HkjkoA

(3) Cutting and filling floors around columns,


stanchions, tubes, pipes, sanitary appliances
and fitting etc.
(4) Laying floors horizontally or to such falls as
directed.

(5) Laying floors in narrow widths or in any


position, unless otherwise provided for.
(6) Protecting floors and their cleaning on
completion.
(b) The rates in this section shall apply to floors and
pavings whether inside or outside the buildings
(including sheds and hangers), roads, aprons,
airfield and similar works other than flexural
concrete which is covered under section 20-B.
(c) When concrete in sub floor, paving, floor, runway
etc. is more than 25cm in thickness, these shall
be measured as concrete in foundation, use and
waste of side forms if required, shall be measured
separately except flexural concrete which shall
be covered under section 20-B.

ii v/k vk/kkj] vk/kkj] v/kQ'kZ ;k iw.kZ Q'kZ fcNkus ls


rqjUr igys Hkwfe dks lkQ djuk ;k ikuh nsuk ;fn
funsZf'kr gkss
LrEHkks]a [kEHkks]a ufy;ks]a uyks]a lQkbZ midj.kksa o miLdjksa
vkfn ds pkjksa vksj Q'kZ dh dVkbZ vkSj HkjkbZ
lekukUrj ;k vU; crk;s x;s rjhds ds vuqlkj Q'kZ
fcNkuk
ladh.kZ pkSM+kbZ esa ;k fdlh vU; n'kk esa tc rd dh
vU;Fkk ,slk iwoZ fu/kkfjr u gks] Q'kZ fcNkuk
Q'kZ ds iw.kZ gksus ij mldh lqj{kk vkSj lQkbZA

[k bl Hkkx dh njsa] Q'kksZ vkSj [kaMts fcNkus ij ykxw gksaxh pkgs


og Hkou ds vUnj gks ;k ckgj vkSlkjs o gSaXkj lfgr lM+dsa]
ijh fcNkou] gokbZ ih vkSj lerqY; flok; yphyh dahV
ds tksfd Hkkx 20 [k ds vUrZxr vkrh gSA
x tc v/kvk/kkj] [kaMtk fcNkus] Q'kZ] gokbZ ih vkfn esa dahV
25 lsa-eh- ls vf/kd gksa rks ;g uho esa dahV ds leku ekih
tk;sxh] fdukjksa dh mi;ksx o Nhtu ;fn ckaNuh; gks rks vyx
ls ekih tk;sxh flok; yphyh dahV ds tksfd Hkkx 20 [k ds
vUrxZr vkrh gSA

254

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
SPECIAL CONDITIONS & Contd..
fo'ks"k 'krsZ & tkjh
(d) The rates for concrete flooring when applied to
concrete roads, airfields, aprons, hangar floors
and similar work in large areas, shall be deemed
to include for the requirements of the
supplementary specifications given in Section
20Roadwork.

?k dahV Q'kZ fuekZ.k dh njsa tc dahV dh lM+dksa gokbZ if;ks]a


ijh lrgks]a foeku 'kkykvksa ds Q'kksaZ vkSj bl tSls leku dk;Z
tks fo'kky {ks=ksa esa fd, x;s gksa dks [kaM 20& *lM+d fuekZ.k*
esa fufgr funsZ'ku ifjf'k"V ds vUrxZr ekU; gskxkA

13.3 Work in Patches, in Repairs


Payment for flooring in patches in repairs, shall be made
as under:The rates include for cleaning and preparing the base
and sides of patches.
(NOTE: New work in small quantities shall not be treated
as work in patches).

13-3 ejEer esa isou dk;Z


Q'kZ esa isou ds dk;ksZ dk Hkqxrku fuEu izdkj ls gksxk%&

(1)

Patches exceeding
3 sq.m each

At the rate for new


work plus dismantling
or demolition, if any.

1 3 o-eh- ls vf/kd ds izR;sd isou uohu dk;Z nj tek rksM


QksM] ;fn gksA

(2)

Patches not exceeding


3 sq.m each

At the rate for new


work plus 10 percent
extra, plus dismantling
or demolition, if any.

2 3 o-eh- ls vuf/kd ds izR;sd isou uohu dk;Z nj tek 10


izfr'kr tek rksM+ QksM] ;fn
gksA

bu njksa esa lQkbZ vkSj vk/kkj vkSj isou fdukjksa dks cukuk 'kkfey gSA
uksV% FkksM+h ek=k ds uohu dk;Z isou dk;Z ugha ekus tk;saxs
uks

STONE SLAB FLOORS


iRFkj ifV;k Q'kZ
(a)

(b)

(c)

d iRFkj if;ka dh njksa esa Q'kZ vkSj [kM+h lrgs tSlh dh xksVu@MSMks
esa] nhokj dh fupyh lrgs bR;kfn vkSj dkV NkV Nhtu nkrs
cukuk ;k [kqjpuk] lfUufgr gSA
Where the use of stone slabs other than rectangular or [k tgka vk;rkdkj ;k pkSjl ds vfrfjDr ifV;k dk lek;kstu
square in plan is involved, such slabs shall be measured
iz;ksx gks rks ,slh ifV;k ds fy, ml NksVs ls NksVs vk;rkdkj
as the least rectangle from which the slab can be cut.
iRFkj dks ekik tk;sxk ftlls ml ifV;k dks cuk;k tk ldrk
gksAa
The rates include for making fair, rounded, chamfered, x bu njksa esa lkQ] xksy] i[knkj] <kyw ;k csoy fdukjs cukuk
splayed or bevelled edges, where directed.
'kkfey gSA
The rates for stone slabs in floors and in vertical surfaces
such as in skirtings, dados, etc. include for all cuttings
and wastes, for notching and scrubbing.

255

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
STONE SLAB FLOORS - Contd...
iRFkj ifV;k Q'kZ - tkjh
cyqvk iRFkj dh ifV;k Q'khZ dk;Z

SAND STONE SLAB FLOORING


M&L

Except Stone

lkexzh ,oa Je

fcuk iRFkj

Thickness in mm

Thickness in mm

eksVkbZ feeh esa

eksVkbZ feeh esa

PER SQUARE METRE

13001Rough dressed sand stone


slab flooring, laid dry but
jointed and pointed in

cement mortar 1:3


13002Ditto, but bedded and
jointed in lime mortar 1:3
and pointed in cement

mortar 1:3
13003Ditto, but bedded and
jointed in cement mortar 1:6
and pointed in cement

mortar 1:3
13004Ditto, but bedded, jointed
and pointed in cement
mortar 1:3 in vertical

surfaces

25

30

40

25

Rs.
Rs.
Rs.
Rs.
180.80 192.50 235.60 86.90

13001 cyqvk iRFkj dh eksVh x<h ifV;k


Q'kZ esa lw[kh fcNh ijUrq 1%3 ds lhesVa
Rs.
elkys ls tqMh+ o Vhi dh gqbZ tqMh

40

Rs.
86.80 106.40

13002
13002mi;qZDr] ijUrq vkSj 1%3 ds pwuk
elkys esa fcNh o tqM+h vkSj 1%3 ds
217.10 238.50 283.70 123.20 132.80 155.30 lhesaV elkys ls Vhi dh gqbZ
13003
13003mi;qZDr] fdUrq o 1%6 ds lhesaV
elkys esa fcNh] tqM+h o 1%3 ds

lhesaV elkys ls Vhi dh gqbZ


232.10 240.00 285.70 130.00 138.20 161.00
13004
13004mi;qZDr] fdUrq [kMh Lrj ij 1%3
ds lheasV elkys esa fcNh] tqMh o
Vhi dh gqbZ
255.40 267.10 314.40 161.80 161.80 185.70

LIME STONE SLAB


FLOORING
13005Rough dressed lime stone
slab flooring, laid dry,
jointed and pointed in

cement mortar 1:3


13006Ditto, but bedded and
jointed in lime mortar 1:3
and pointed in cement

mortar 1:3
13007All as in item 13005 but
bedded and jointed in cement
mortar 1:6 and pointed in

cement mortar 1:3


13008Ditto but bedded, jointed
and pointed in cement
mortar 1:3 in vertical

surfaces

30

izfr oxZ ehVj

pwuk iRFkj ifV;ksa ds Q'kZ


13005
13005pwuk iRFkj dh eksVh x<+h ifV;k
Q'kZ esa lw[kh yxkdj ijUrq 1%3 ds

lhesVa elkys ls tqMh+ o Vhi dh gqbZ


192.50 204.30 270.90 86.80 86.80 106.40
13006
13006mi;qZDr fdUrq 1%3 ds pwuk elkys
esa fcNh] tqM+h o 1%3 ds lhesaV
238.50 250.20 319.40 132.70 132.70 154.90
elkys ls Vhi dh gqbZ
13007
13007lc en 13005 tSlk] fdUrq lhesaV
elkyk 1%6 esa fcNh o tqMh+ vkSj 1%3
246.10 279.30 370.00 138.60 160.60 205.50 ds lhesaV elkys esa Vhi dh gqbZ
13008
13008mi;qDZ r] fdUrq 1%3 ds lhesVa elkys
esa [kM+h lrg ij fcNh] tqMh o Vhi
267.10 302.60 396.70 161.40 185.10 232.20
dh gqbZ

13009Extra over stone slab flooring, if stone slabs


are laid as in risers and treads of stairs

Rs.
32.20

13010Deduct if joints in rough dressed stone slab


flooring are struck flush as the work proceeds

43.50

13009 vfrfjDr iRFkj dh ifV;k ds lhf<+;ksa ds iknksa o


mBkoksa gsrq
13010 ?kVkb,] ;fn eksVh x<+h iRFkj dh ifV;k Q'kZ dk;Z
ds nkSjku njkj [kk tk;

256

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk

(a)
(b)

STONE SETT FLOORING


iRFkj pkS d s ls Q'kZ la i w f rZ
Unless otherwise indicated, stone setts used in any one d tc rd fd vU;Fkk
area shall be of uniform size.
iz;qDr ,d Lo:i
Channels formed in the stone sett floor shall be girthed
and included in the floor area.
PER SQUARE METRE

13011Stone sett flooring with stone


setts of size 200 to 250mm long,
150 to 200mm wide and 150mm
deep and sides dressed; bedded
in cement mortar 1:3, joints
20mm thick; grouted in cement
mortar 1:2 with an admixture of
metallic floor hardner 5% by
weight of cement and struck

flush
13012Edge stones to flooring with
stone setts of size 250 to 300mm
long x l50 to 200mm wide, and

450mm deep and ditto

M&L

Except stone setts

lkexzh ,oa Je

fcuk iRFkj pkSds

Rs.

Rs.

461.30

277.90

lwfpr u gks iRFkj pkSds fdlh ,d {ks= esa


okys gksxsaA

izfr oxZ ehVj


13011 iRFkj pkSdksa ds Q'kZ ftlesa pkSds 200 ls
250 fe-eh- yEcs] 150 ls 200 fe-eh- pkSMs+
vkSj 150 fe-eh- eksVs pkjksa vksj ls rjk'ks gq,
1%3 ds lhesVa elkys esa fcNk;s gks] 20 feeh- ?kuRo okys tksMk+ as dks 1%2 ds xhys lhesVa
elkys ftlesa lhesVa ds otu ds 5%
/kkrq fefJr Q'kZ nqoks/Z ; ls Hkjk x;k gksA

13012 Q'kZ esa fdukjksa ds iRFkj tks 250 ls 300


fe-fe- yEcs 150 ls 200 fe-eh- pkSM+sa]
vkSj 450 fe-eh- xgjs vkSj mi;qZDr
797.70

478.70

KOTA STONE FLOORING


dksVk iRFkj ls Q'kZ fuekZ.k
(a)

(b)

The rates of kota stone flooring includes for all cutting


and waste including machine cutting to make it square or
rectangular.
The rate includes for cutting and polishing by machine.

d dksVk iRFkj ds Q'kZ dh njksa esa lHkh dVkbZ] Nhtu] e'khuh


dVkbZ }kjk iRFkj dks vk;rkdkj ;k pkSdksj cukuk 'kkfey gSA
[k bu njksa esa e'khu }kjk dVkbZ vkSj ikfy'k djuk 'kkfey gSA

x ;fn ekse ls ikfy'k dk funs'Z k gksrk gS] rks og bl vuqlp


w h dh
en 13059 ds vUrxZr ns; gksxhA
(d) The rates do not include for under layer and dividing ?k bu njksa esa fupyh rg vkSj foHkktd ifV;k 'kkfey ugha gSA
(c)

Wax polish to kota floor if ordered shall be paid under


Schedule Item 13059.
strips.
PER SQUARE METRE

13013 Machine cut kota stone slab


flooring 20-25mm thick over
cement screed base laid and
jointed with grey cement slurry
mixed with pigment to match the
shade of the slab including rubbing

and polishing complete

13014 Ditto, but 40-50mm thick


13015 Kota stone slab 20-25mm thick
in riser of steps, skirting, dado
and pillar laid over cement
screed and jointed with ditto as

per item 13014

M&L

Except stone

lkexzh ,oa Je

fcuk iRFkj ds

Rs.

Rs.

538.50

222.40

693.60

572.70

241.20

253.50

izfr oxZ ehVj


13013 e'khu ls dVh dksVk iRFkj ifV;k 20&25
fe-eh- eksVh vkSj lhesaV fc[kjs vk/kkj
ij Hkwjs lhesVa esa iRFkj ds jax ls feyrh
gqbZ lkexzh feykdj fcNkou vkSj tksM+
dj] jXkM+ dj vkSj ikfyl djds laifw rZ

13014 mi;qZDr] ijUrq eksVkbZ 40&50 fe-eh

13015 dksVk iRFkj dh ifV;k 20&25 fe-eheksVh] lhf<+;ksa ds p<+kouksa xksVu nhokj
MkMksa o [kEHkksa esa lhesaV fcNkou ij
fcBkuk] vU; en 13014 tSlk

257

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
DRY STONE FLOORS
iRFkj ds Q'kZ
PER SQUARE METRE

M&L

lkexzh ,oa Je
150 mm
thick

150 feeheksVk

13016 Approved quarried stone


laid dry, in pavings, face
hammer dressed, sides
fitted fairly, hollows
wedged in with stone chips
and interstices filled with

approved earth
13017 Add, if joints are grouted flush
with cement mortar 1:6

izfr oxZ ehVj

Except stone

fcuk iRFkj ds

Add or 150mm Add or


deduct
thick
deduct
for each 150 feeh- for each
25 mm
eksVk
25 mm
over or
over or
under
under
150mm
150mm

150 feehls de ;k
T;knk ij
izR;sd 25
feeh- ds
fy;s tksM+sa
;k ?kVk;sa

150 feehls de ;k
T;knk ds
fy;s izfr 13016 Lohd`r [kuu iRFkj] [kaMtksa esa lw[kk
fcNk] gFkkSM+s ls lery fd;k] Nksjksa
25 feehdks Bhd izdkj fcBkdj fNnzksa dks
ij tksM+sa
iRFkj ds NskVs VqdM+ksa ls Hkjdj o
;k ?kVk;sa
njkjsa Lohd`r feh ls Hkjh gqbZ
Rs.

Rs.

Rs.

Rs.

139.80

20.90

44.90

6.40

48.00

9.40

48.00

9.40

13017 tksM+sa] ;fn tksM+ksa dks 1%6 ds lhesaV


elkys ls tksM+k x;k gksA

MARBLE SLAB TILE FLOORING


laxejej if;ka Q'kZ fuekZ.k

d bu njksa esa ijr fcNkus ;k QSykus dk dk;Z lfEefyr ugha gS]


ijUrq Vkbyska dks lhesVa ds ?kksy ;k lysjh ls fcNkuk ;k tksMu+ k
lfUufgr gSA
(b) The rates include for all straight cutting and waste. Raking [k njksa esa lc izdkj dh dkV vkSj Nhtu lfUufgr gS] frjNh ;k
or circular cutting and waste shall be measured separately.
o`rkdkj dkV vkSj Nhtu vyx ls ekis tk;sxsaA
(a) The rates are exclusive of bedding layer or screed but
include for setting and jointing the tiles in cement paste or
slurry.

x bu njksa esa dVkbZ vkSj ikfy'k djuk lfUufgr gSA


(d) Wax polishing to marble tile floor, etc. shall be paid, under ?k laxejejh Vkbyksa ds Q'kZ ij ekse ikfy'k vkfn en 13059 ds
item 13059
vUrxZr ns; gksxhA
(c) Rates include for cutting and polishing.

258

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
MARBLE TILE FLOORING-Contd...
laxejej if;ka Q'kZ fuekZ.k -tkjh
PER SQUARE METRE

M&L

Except tiles

13018 Marble tiles 30cmx20cm x


20mm thick machine cut, bedded
jointed and pointed with grey
cement slurry including
cutting and polishing types
White Marble

(a) Makrana white

(b) Abu white

(c) Makrana Doogri Adanga

(d) Makrana Chak Dongri

lkexzh ,oa Je

fcuk VkbZy ds

Rs.

Rs.

1268.60

328.60

1092.40

328.60

1151.10

328.60

Black Marble
(a) Black Zebra Bhainsalana
(b) Black Zebra Kishangarh
(c) Abu Zebra Black

izfr oxZ ehVj


13018
13018e'khu ls dkVh gqbZ 30 ls-eh- 20
feeh- eksVh ?kuRo okyh laxejej dh
Vkbysa Hkwjs lhesaV ?kksy esa fcNh] tqM+h o
Vhi dh gqbZ dVkbZ o ikfyl lfgr

lQsn laxejej
d edjkuk lQsn
[k vkcw lQsn
x edjkuk Mwxjh vMaxk
?k edjkuk pkd Mwxjh

dkyh laxejej

13019 Extra if white cement slurry is used


instead of grey cement slurry (in
joints of marble tiles)

2.60

2.60

312.40

13020 20mm thick marble tiles


machine cut in skirting/dado
laid over cement screed and
jointed with grey cement slurry
including cutting and polishing
of type
White Marble
(a) Makrana white
(b) Abu white
(c) Makrana Doogri Adanga

1294.60
1118.30

354.60

Black Marble
(a) Black Zebra Bhainsalana

1177.10

354.60

13021 Extra if white cement slurry is


used instead of grey cement slurry

(in joints of marble tiles)


2.60

d dkyk tScjk HkSlk ykuk


[k dkyk tScjk fd'kux<+
x vkcw tScjk dkyk

13019 vfrfjDr] ;fn Hkwjs lhesaV dh Lyjh ls


LFkku ij lQsn lhesaV dk iz;ksx
fd;k x;k gksA
13020 20feeh eksVkbZ dh laxejejh e'khu ls
dVh VkbZyksa MkMksa dks Hkwjs lhesaV ds
?kksy ls nhokjksa dh xksVu lrg ij
lheasV dh rg ij dVkbZ o ikfyl
lfgr] Hkwjh lhesaV Lyjh ls tqM+h gqbZ

lQsn laxejej
d edjkuk lQsn
[k vkcw lQsn
x edjkuk Mwxjh vMaxk
dkyh laxejej
d dkyk tScjk HkSlk ykuk
13021 vfrfjDr ;fn Hkwjs lhesaV ds ?kksy ds
LFkku ij lQsn lhesVa dk ?kksy laxejej
dh Vkbyksa dks tksM+us esa iz;ksx fd;k
x;k gks

259

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
GRANITE TILE FLOORING
xzsukbV ifV;k Q'kZ fuekZ.k
(a)The rates are exclusive of bedding layer or screed but include d bu njksa esa ijr fcNkus ;k QSykus dk dk;Z lfEefyr ugha gS]
for setting and jointing the tiles in cement paste or slurry.
ijUrq Vkbyksa dks lhesVa ds ?kksy ;k lysjh ls fcNkuk ;k tksMu+ k
lfUufgr gSA
(b) The rates include for all straight cutting and waste. Raking [k njksa esa lc izdkj dh dkV vkSj Nhtu lfUufgr gS] frjNh ;k
or circular cutting and waste shall be measured separately.
o`rkdkj vkSj Nhtu vyx ls ekis tk;sxsaA

x bu njksa esa f?klkbZ vkSj ikfy'k djuk lfUufgr gSA

(c) Rates include for grinding and polishing


PER SQUARE METRE

M&L

13022 Granite (of any type) tiles 20mm


thick machine cut, bedded and
jointed with grey cement slurry
and pointed with white cement
with admixture of pigment to
match the shade of granite stone
including grinding and polishing

complete
13023 20mm thick Granite (of any type)
tiles machine cut, in skirting/
dado laid over cement screed
and jointed with grey cement
slurry, and pointed with white
cement with admixture of
pigment to match the shade of
granite stone including grinding

and polishing complete

lkexzh ,oa Je

izfr oxZ ehVj


fcuk VkbZy ds 13022 e'khu ls dkVh gqbZ 20feeh- eksVh xzus kbV
Rs.
fdlh Hkh izdkj dk dh Vkbysa Hkwjs lhesVa
?kksy esa fcNh] tqM+h o lQsns lhesaV eas
iRFkj ds jax ls feyrh gqbZ lkexzh feykdj
Vhi dh gqbZ f?klkbZ o ikfyl lfgr
Except tile

Rs.

2096.40

333.90

2135.90

373.40

13023 20feeh- eksVh xzsukbV fdlh Hkh izdkj


dk dh e'khu ls dVh VkbZyksa MkMksa dks
Hkwjs lhesaV ds ?kksy ls nhokjksa dh xksVu
lrg ij lhesaV dh rg ij dVkbZ o
ikfyl lfgr] Hkwjh lhesVa lysjh ls tqMh+
gqbZ lQsns lhesaV esa iRFkj ds jax ls
feyrh gqbZ lkexzh feykdj Vhi dh gqbZ
f?klkbZ o ikfyl lfgr

CUDAPPAH STONE SLAB OVER COOKING PLATFORM


idkus okys IysVQkeZ ij dqMIik iRFkj
(a) The rates of cudappah stone slab includes for all cutting d dqMIik iRFkj ds Q'kZ dh njksa esa lHkh dVkbZ] Nhtu] e'khuh
and waste including machine cutting.
dVkbZ 'kkfey gSA
(b) The rate includes for cutting and polishing by machine.
[k bu njksa essa e'khu }kjk dVkbZ vkSj ikfy'k djuk 'kkfey gSA
(c) The rates do not include for under layer and dividing strips.

x bu njksas esa fupyh rg vkSj foHkktd ifV;k 'kkfey ugha gSA


izfr oxZ ehVj
13024 e'khu ls dVh dqMIik iRFkj ifV;k
Except stone
20&25 fe-eh- eksVh vkSj lhesVa fc[kjs
fcuk iRFkj ds
vk/kkj ij Hkwjs lhesaV esa iRFkj ds jax
ls feyrh gqbZ lkexzh feykdj fcNkou
Rs.
vkSj tksM+ dj] jxM+ dj vkSj ikfyl

djds laiwfrZ
77.40

PER SQUARE METRE


13024 Machine cut cudappah stone
slab 20-25mm thick over cement
screed base, laid and jointed
with grey cement slurry mixed
with pigment to match the shade
of the slab including rubbing
and polishing complete

M&L

lkexzh ,oa Je
Rs.
429.90

RUNNING METRE
13025 Rounding to edges of stone
slabs one edge, such as in steps,
cooking platform, and other

similar situations

Rs.
20.60

260

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
PRECAST CONCRETE SLAB FLOORS
iwoZfufeZr dahV ifV;k Q'kZ dk fuekZ.k
The rates for precast concrete slab flooring include for:
iwoZfufeZr dahV ifV;k ls fufeZr Q'kZ dh njsa fuEu dks lfUufgr
djrh gSa%
(i) Finishing exposed surfaces of slabs even and smooth, (i) fcuk lhesV
a iz;ksx ds ifV;ksa dh ijh mHkjh lrg dks le vkSj
without using extra cement.
fpduk cukukA
(ii) Making fair, rounded, chamfered, splayed or bevelled (ii) tgka funsfZ 'kr gks frjNs ,d vksj c<+s gq, ;k vleku fdukjksa dks]
edges, where directed.
lkQ] xksy djukA
(iii) Forming any grooves for laying in skirtings, risers, treads, (iii) xksVu mBkoks]a ik;ksa esa lh/ks [kM+s ;k >qds LFkkuksa esa yxkus ds fy,
straight or winding.
[kkpsnkj cukukA
(iv) Any cutting and waste; and notching and scrubbing.
(iv) dksbZ dVkbZ o Nhtu vkSj nkars fudkyuk vkSj [kqjpukA
(v) Laying slabs in vertical scrubbing.
(v) [kMh lrg ij ifV;k fcNkukA
PER SQUARE METRE
13026Precast cement concrete
type B-1, 1:2:4 (20mm
graded stone aggregate)
slab flooring, bedded,
and jointed in cement
mortar 1:6 and pointed in

cement mortar 1:3


13027Ditto, but with cement
concrete type C-1, 1:3:6
slabs flooring and ditto

M&L

lkexzh ,oa Je

dahV ifV;k jfgr 13026 iwoZ fufeZr dahVch&1 izdkj 1%2%4


Thickness in mm
20fe-eh- oxhZd`r iRFkj feykok]
eksVkbZ feeh esa
ifV;k Q'kZ 1%6 lhesaV elkys esa
40
50
fcNh o tqM+h vkSj 1%3 ds lhesaV
Rs.
Rs.
elkys esa Vhi dh gqbZ

Thickness in mm

eksVkbZ feeh esa


40

50

Rs.

Rs.

284.80

333.30

273.30

308.40

172.60

185.30

172.60

13027 mi;qDZ r] ijUrq lhesVa dahV lh&1


izdkj dh 1%3%6] ifV;k Q'kZ vkSj
184.90
mi;qZDr

Rs.

13028 Add to item 13026 and


13027 if slabs are
finished even and smooth
using extra cement

izfr oxZ ehVj

Except concrete slabs

13028 en 13026 vkSj 13027 esa tksMas+ ;fn


ifV;k le vkSj pednkj cukus esa
vfrfjDr lhesV
a dk iz;ksx fd;k gks

18.10

LIME CONCRETE SUB-FLOORS OR BASES


pwuk dahV v/kQ'kZ ;k vk/kkj
The rates include for finishing surfaces of lime concrete even bu njksa esa pwuk dahV dh lrg dks ijh rg fcNkus o Qjescanh
and rough to receive the topping layer and also use and waste ;ksX; le ;k [kqjnjk cukus ds dk;Z esa mi;ksx o Nhtu 'kkfey gSA
of form work.

PER SQUARE METRE

75mm

Add or deduct for each 25mm

izfr oxZ ehVj


75 feeh over or under 75 mm thickness
75 feeh ls de ;k vf/kd
ij izfr 25 feeh- eksVkbZ gsrq
ds fy;s tksM+sa ;k ?kVk;sa
13029
13029v/kQ'kZ esa pwuk dahV pwus elkys 1%2
13029 Lime concrete with lime mortar 1:2
mix and 40mm graded stone coarse

aggregate in sub-floors
13030 Ditto, but with lime mortar 1:3 mix
13031 Lime concrete with lime mortar
1:2 mix and 40 mm graded brick
coarse aggregate in sub-floors

13032 Ditto, but with lime mortar 1:3 mix

Rs.
211.80
201.40

Rs.
48.40
44.90

207.70
197.40

47.00
43.60

ds feJ.k vkSj 40 fe-eh- iRFkj jksMh


feJ.k lewg lfgr
13030 mi;qDZ r] ijUrq pwuk elkyk 1%3 feJ.k lfgr
13031
13031pwuk dahV] pwuk elkyk 1%2 feJ.k
vkSj 40 fe-eh- dksfV dh bZV jksMh lewg
lfgr v/k% Q'kZ esa
13032 mi;qDZ r] ijUrq pwuk elkyk 1%3 feJ.k lfgr

261

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
CEMENT CONCRETE IN SUB-FLOORS, SUB-BASES, FLOORS AND PAVINGS, ETC.
lhesaV dahV ls v/kQ'kZ] v/k vk/kkj] Q'kksZa rFkk [kaM+tksa vkfn dk fuekZ.k
(a) The rates of cement concrete in flooring include for:
(i) Use and waste of form work/screed strips and to
divide the area in panels. Where dividing strips
are used, these shall be measured separately,
without any price adjustment.
(ii) Finishing surfaces of concrete topping even and
fair (without using extra cement), and finishing
surfaces of concrete in sub-floors, sub-bases, etc.
even and rough to receive the topping layer.

d lhesaV dahV ds Q'kZ dh bu njksa esa fUkEu lfUufgr gS%


(i) Qjescn
a h@yach ifV~V;ksa o {ks= dks [kaMksa esa foHkkftr djus
esa mi;ksx o NhtuA tgka foHkktd ifVV;ka iz;ksx dh xbZ
gSa] fcuk fdlh ewY; O;oLFkk ds izFkd ekih tk;saxhA

(iii) Finishing exposed edges fair or rounding or


chamfering of exposed edges, where directed.
(iv) Laying concrete in narrow widths, risers,
treads, landings and the like.
(b) Different layers of cement concrete floors shall be
measured separately, unless laid monolithically.

[k

(c) For joints in large paving, see Section 20A


Roadwork. These joints shall be measured separately.

(d) Forming channels shall be measured and paid for under


items 04079 and 04080. Deductions and/ or additions
of concrete shall be adjusted under item 04026.

?k

(e) For work in flexural concrete Airfield pavement and


hard standing, refer section 20-B.

100mm
thick

PER SQUARE METRE

100 feeh eksVh

dahV dh ijh lrg dks lery] LoPN vkSj lqUnj


cukuk fcuk vfrfjDr lhesaV iz;ksx fd,] vkSj v/kQ'kZ]
v/kvk/kkj vkfn dh lrg lery o fpduh djuk ftlls
ml ij ijh rg fcNkbZ tk ldsA
(iii) ckgj fudys fdukjksa dks Bhd ;k xksy djuk vkSj tgka
funsZf'kr gks ijh fdukjksa esa f>fj;k cukukA
(iv) lah.kZ pkSMk+ bZ mBkuks]a ik;nkuks]a vorj.kksa vkSj blh izdkj
ds dke esa dahV fcNkukA
lhesVa dahVdh fHkUu rgsa vyx&vyx ekih tk;sx
a h] tc rd
fd v[kaM u Mkyh xbZ gksA
cM+s [kM+t
a ksa esa tksMk+ as ds fy, Hkkx&20 d ns[a ks-a lM+d dk;ZA ;g
tksM+ vyx ls ekis tk;saxsA
iz.kky cukbZ en 04079 vkSj 04080 esa ekih o ns; gksxhA
dVksfr;ka vkSj@;k vf/kd dahVdh en 04026 ds vUrxZr
O;oLFkk gksxhA
foeku LFkyksa ds [kaMtksa esa izokgu dahVHkjkbZ vkSj Bksl LFkkbZ
dahVds fy, Hkkx&20 [k ls lanHkZ ysaA
(ii)

Add or deduct for


each 25mm over or
under 100mm thickness

izfr oxZ ehVj

100 feeh- ls vf/kd ;k de


ij izfr 25 feeh- eksVkbZ
gsrq tksM+s ;k ?kVk;sa
13033Cement concrete type B- 2,
1:2:4 (40mm graded
aggregate)
13034Ditto type C-2, 1:3:6 (ditto)

Rs.

Rs.

305.80

72.60

256.90

60.40

13035Ditto type D-2, 1:4:8 (ditto)

230.10

53.70

13033
13033lhesaV dahV oxZ ch&2] 1%2%4
40 fe-eh- Js.kh feykok
13034
13034mi;q Z D r oxZ lh&2] 1%%3%6
mi;qZDr
13035
13035mi;q Z D r oxZ Mh&2] 1%4%8
mi;qZDr

262

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
CEMENT CONCRETE IN SUB-FLOORS, SUB-BASES, FLOORS AND
PAVINGS, ETC. & Contd...
lhesaV dahVls v/kQ'kZ] v/k vk/kkj] Q'kksZa rFkk [kaM+tksa vkfn dk fuekZ.k & tkjh
PER SQUARE METRE

13036Cement concrete type B-1,


1:2:4 (20mm graded

aggregate)
13037Ditto type B-0, 1:2:4
(12.5mm graded aggregate)

13038Add to foregoing, if
reinforced (Reinforcement
measured separately)

PER SQUARE METRE

25mm thick

izfr oxZ ehVj

Add for each extra 15mm

25 feeh eksVh

izR;sd 15 feeh vfrfjDr


gsrq tksMsa+

Rs.

Rs.

91.90

46.60

120.30

47.00

13036
13036lhesaV dahV oxZ ch&1] 1%2%4
20 fe-eh- Js.kh feykok

13037
13037mi;qZDr] oxZ ch&0] 1%2%4 12-5
fe-eh- Js.kh feykok
13038
13038fiNyh enksa esa tksM]+as ;fn izofyr
izoyu vyx ls ekik tk;sxk

2.20

Finished thickness of coloured topping

iwjh HkjkbZ dh jaxhu liawfjr eksVkbZ


3 mm

izfr oxZ ehVj

Add for additional


3 mm

3 feeh

3 feeh vfrfjDr gsrq tksMsa


13039Add to concrete floors for
coloured cement mortar 1:2
finish including polishing

13040Finishing cement concrete


surface even and smooth

Rs.

Rs.

147.90

27.00

Using extra
cement

Without using
extra cement

vfrfjDr lhesaV iz;ksx

fcuk vfrfjDr lhesaV


iz;ksXk

Rs.

Rs.

18.10

10.60

13041Spike rolling to surfaces or making


impressions of expanded metal, whilst the
concrete is green

Rs.
3.40

13039
13039tksM+sa] jaxhu lheasV elkyk 1%2
ls dahVQ'kZ laifw kZ ikfy'k lfgr

13040
13040lhesaV dahV dh lrg lery
vkSj fpduh laiwfjr

13041
13041lrg ij fyiVok dhyd ;k /kkrq dh tkyh ls rc rd
fpfUgr djuk tc rd dahV gjh gksA

263

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
CEMENT CONCRETE IN SUB-FLOORS, SUB-BASES, FLOORS AND
PAVINGS, ETC. & Contd...
lhesaV dahVls v/kQ'kZ] v/k vk/kkj] Q'kksZa rFkk [kaMtksa vkfn dk fuekZ.k & tkjh
lkexzh ,ao
Je

Except
aggregate

xzsukbV nkusnkj dahV Q'kZ

feJ.k jfgr

Rs.

Rs.

91.60

84.59

16.00

12.68

13042
13042xzsukbV nkuksa dh 30 fe-eh- eksVh 1%1%2
dahV ds v/kQ'kZ vkfn esa fcNh rFkk lrg
dks lery vksj fpduk djds laiwfkZ
13043vafre en esa tksMsa ;k esa ls ?kVk;sa 30
13043
fe-eh- ls vf/kd ;k de esa izR;sd 5 fe eh- ds fy,
13044
13044en 13042 ds fy, vfrfjDr lh<+h iknksa
p<koks]a xksVuksa vkfn esa tks pkSMk+ bZ ;k mWpkbZ
esa 30 lsa-eh- ls vf/kd u gks

M&L

GRANOLITHIC
CONCRETE FLOORS
13042Granolithic concrete 1:1:2 floor
topping 30mm thick; laid over cement
concrete subfloors etc. and finished

to an even and fair surface


13043Add to (or deduct from) last item for
each 5mm thickness over (or under)

30mm
13044Extra over item 13042 for laying
granolithic topping in treads, risers,
skirtings, etc. n exc 30cm in width
or height
13045Ditto, in dados exc 30cm in height

13046Dusting surfaces of granolithic


concrete with carborundum powder

47.30

13045
13045mi;qZDr] 30 lsa-eh- ls vf/kd mWpkbZ nhokj
dh ryh ds ltkoVh fdukjksa esa
13046
13046dkjoksjsUMe ls xzsukbV nkus dh lrg dh
jxMkbZ lkQ djuk

52.00
14.30

WEARPROOF TOPPING
ttZ j rk 'kks " kd
Metallic hardner shall be measured separately and paid at 'Supplied only' rates.
/kkrq dk nqoksZ/; vyx ls ekik tk;sxk vkSj **dsoy vkiwfkZ** dh njksa ij ns; gksxkA
M&L

Except materials

lkexzh ,oa Je

lkexzh jfgr

PER SQUARE METRE


13047 Wearproof topping as
specified (incorporating
an approved metallic
floor hardner), laid on
concrete floors and
pavings, and finished
even and smooth (except

metallic hardner)

Thickness of topping in mm

mij dh eksVkbZ feeh esa


15

20

15

20

Rs.

Rs.

Rs.

Rs.

117.10

160.90

56.50

70.80

izfr oxZ ehVj


13047
13047ttZjrk 'kks/kd lrg tSlk fd
fufnZ"V fd;k gks ,d Lohd`r
/kkrq ds nqcksZ/; dks feykdj
dahVds Q'kZ vkSj [kaMtksa esa
fcNkuk vkSj lery vkSj
pedhyk cukuk /kkrq ds
nqckZs/; dks NksM+dj

264

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
WEARPROOF TOPPING & Contd...
ttZjrk 'kks"kd & tkjh
Rs.

PER SQUARE METRE


13048 Treating cement concrete or granolithic
concrete surfaces with three dressings

of sodium silicate solution

12.00

13049Roughening surfaces of old concrete


floor by picking, sweeping clean and
washing down with water to remove

dust, etc.
13050 Brushing neat cement slurry with 3.0kg

of cement per sq. metre

10.70

izfr oxZ ehVj


13048 lhesVa dahV ;k xzus kbV nkuk dahVdh lrgksa ij
lksfM;e vkSj lQsn lhesaV ds ?kksy dh rhu ijrsa
yxkuk
13049 iqjkus lhesaV dahV ds Q'kZ dh [kqjnjh lrg dks
jxM+dj] >kMw yxkdj vkSj ikuh ls /kksdj /kwy vkfn
lkQ djuk

13050 3-0 fd-xzk- lhesaV izfr oxZ ehVj dh lysjh djuk

18.90

TERRAZZO CAST IN - SITU


VSjstks <ykbZ lhVw esa
The rates for terrazzo topping do not include for underlayer and dividing strips.
rjStks dh njksa esa ryh; vLrj vkSj foHkktd if;kW 'kkfey ugha gSA
PER SQUARE METRE

13051 6mm thick terrazzo


topping with 2 to 4mm
size marble aggregate
including grinding and
polishing in floors
13052 Add or deduct from last
item for each mm
thickness over or under

6mm

With grey
cement
and no
pigment

With grey
cement
and
pigments

Hkwjk lhesaV
jax jfgr

Hkwjk lhesaV
jax lfgr

Rs.

Rs.

392.00

417.90

28.90

31.40

With mixture of grey


and white
cement in
equal proportions

With
white
cement
and
pigments

32.30

36.10

izfr oxZ ehVj

lQsn lhesaV
Hkwjs o lQsn jax lfgr
lhesaV ds le
feJ.k esa
130516 feeh eksVh VSjstks dh ijr] 2
13051
jaxghu
ls 4 feeh eki rd laxejej
Rs.
Rs.
nkuk feykos ds lkFk Q'kZ jxM+kbZ
413.20
439.60
vkSj ikfy'k lfgr
13052
13052tksMsa+ ;k ?kVk;sa fiNyh en eas 6
feeh ?kUkRo ls vf/kd ;k de]
izfr feeh gsrq

265

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
TERRAZZO CAST IN-SITUContd...
VSjstks <ykbZ lhVw esatkjh

PER SQUARE METRE

With grey With grey


cement
cement
and no
and
pigment pigment

Hkwjs lhesaV Hkwjs lhesaV


esa jax
esa jax
jfgr
lfgr
13053 10mm thick terrazzo
topping with 4 to 7 mm
size marble aggregate
including grinding and

polishing in floors
13054 Add or deduct from last
item for each mm thickness
over or under 10mm

Rs.
497.50

13055 15mm thick terrazzo


topping with 7 to 10mm
size marble aggregate
including grinding and

polishing in floors
13056 Add or deduct from last
item for each mm thickness
over or under 15 mm

655.10

13057 Add to items 13051, 13053


and 13054 for work on
vertical surfaces as in
dados, etc. exc 30cm in

height
13058 Add to items 13051,
13052 and 13055 for work
on vertical surfaces as in
skirtings, risers and treads
of steps and on narrow
widths n. exc 30cm in

height or width
13059 Add for treating the surface
with beeswax polish

29.10

29.80

izfr oxZ ehVj

With mixture With


of grey and
white
white cement cement
in equal proand
portions and pigments
no pigment
lQsn

Hkwjs o lQsn lhesaV esa


lhesaV ds le jaxhu jax
s ks dh ijr] 4 ls 7
feJ.k esa
lfgr 13053 10feeh VSjt
feeh
eki
dh laxejej nkus
jaxghu
feykos ds lkFk] jxMkbZ vkSj ikfy'k
Rs.
Rs.
Rs
lfgr
521.00
534.20
574.60
13054 fiNyh en esa 10 feeh ls vf/kd
;k de ds fy, izR;sd ,d feeh
eksVkbZ gqrs tksM+s ;k ?kVk;sa
31.90
32.50
36.30
13055 15 feeh- VSjstkss dh ijr 7 ls
10 feeh- eki dh laxejej nkus
feykos ds lkFk Q'kZ dh jxMkbZ
vkSj ikfy'k lfgr
690.40
708.80
771.30
13056 fiNyh en esa 15 feeh ls vf/kd
;k de ds fy;s izR;sd ,d feeh
32.10
34.70
37.90
eksVkbZ gsrq tksM+sa ;k ?kVk;sa
13057 en 13051] 13053vkSj 13054 esa
Rs.
tksaM+sa] [kM+h lrg ds fy, tSls
fd MkMksa vkfn esa WpkbZ 30 lseh
ls vf/kd
57.30
13058 en 13051] 13052 vkSj 13055 esa
tksMas+ [kMh lrg ds fy, tSls fd
xksVuksa ;k lh<h ds in ds mBkoksa
o ladh.kZ pkSMk+ bZ ij 30 lsea h- ls
vf/kd apkbZ ;k pkSMk+ bZ esa
52.40
9.80

13059 tksM+sa] e/kqeD[kh ekse ls ikfy'k


gsrq

266

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
CEMENT CONCRETE IN SUB-FLOORS, SUB-BASES, FLOORS, PAVINGS ETC.Contd.
v/k Q'kZ] v/k vk/kkj] Q'kksaZ] [kaMtksa vkfn esa lhesaV dahVtkjh

foHkktd if;kW

DIVIDING STRIPS
Width of strip

PER RUNNING METRE

iz f r ehVj

ih dh pkSM+kbZ

13060 Aluminium
dividing
strips, 1.5mm thick,
inserted in position,

conform to design
13061 Plastic dividing strips,
1.5mm thick and ditto

22mm

28mm

38mm

Rs.

Rs.

Rs.

29.90

35.80

47.50

18.10

21.70

28.70

9.90

11.80

15.60

13062 Glass dividing strips, 3 mm

thick and ditto

13060 vyeksfu;e dh foHkktd if;kWa 1-5


feeh- eksVh fn;s gq;a s vkd`fr vuqlkj
cukus ds fy, LFkkfir djuk
13061 IykfLVd dh foHkktd
if;k 1%5 feeh- eksVh o 'ks"k
mi;qZDr
13062 dkap dh 3 feeh- eksVh foHkktd
if;k o 'ks"k mi;qZDr

BRICK FLOORS

bZV ds Q'kZ
(a) The rates of brick flooring include for ordinary cutting
and waste in closers, etc., in rectangular areas. If paving is
laid herring-bone pattern or diagonally, in rectangular
areas, raking, cutting and waste shall be allowed to the
edges of such areas.

d bZV ds Q'kZ fuekZ.k dh njksa esa vk;rkdkj {ks= ds vgkrksa vkfn esa
lkekU; dVkbZ o Nhtu 'kkfey gSA ;fn bZVas [kM+h ;k d.kZ
js[kkor] vk;rkdkj {ks= esa fcNkbZ xbZ gS]a rks bl izdkj ds
vk;rkdkj {ks= ds fdukjksa ds fy;s dVkbZ o Nhtu Lohdk;Z gksxkA

(b) The rates for floors laid dry include for laying on and
including 25mm thick layer of sand and filling the joints
with same. The rates for floors laid dry but pointed in
mortar also include for laying on and including 25mm
thick layer of sand and filling of joints with same.

[k lq[kh fcNkbZ xbZ bZVkas ds Q'kZ dh njksa esa 'kkfey gS] 25 feeh
eksVh okyw dh rg fcNkuk vkSj mlh ls tksMk+ sa dks HkjukA lw[kh
fcNh bZVksa ds Q'kZ ij ;fn elkys ls Vhi Hkh dh xbZ gks rks blesa
fcNkou vkSj 25 feeh okyw dh rg vkSj mlls tksMk+ sa dk Hkjko
Hkh 'kkfey gksxkA

267

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
BRICK FLOORS - Contd...
bZV ds Q'kZ - tkjh
PER SQUARE METRE

Laid
dry

Laid dry Bedded and


and
jointed in
pointed lime mortar
in cement
1:3 and
mortar
pointed in
1:3
cement
lw[kh fcNkbZ mortar 1:3

lw[kh
fcNkbZ

o Vhi lhesaV pwuk elkyk


elkyk 1%3 1%3 esa fcNkbZ
o TkksM+uk
rFkk lhesaV
1%3 esa Vhi
13063Bricks, sub class B,
Rs.
laid flat, in floors, old

size bricks
147.50
13064All as in item 1845,
38.90
but except bricks
13065Bricks, sub class B,
laid on edge in floors;
208.00

old size bricks


13066Ditto, but modular

bricks
53.90
13067Ditto, except bricks

Bedded and
jointed in
Cement
mortar 1:6
and pointed
in cement
mortar
lhesVa elkyk 1:6

tksMs
;fn
esa fcNkuk vkSj bZV
tksMu+ k rFkk
mi
lhesaV elkyk Js.kh ,
esa Vhi djuk
gS
1:6

1:3

Rs.

Rs.

Rs.

Rs.

183.00

200.00

197.70 216.50

74.40

91.30

89.00 111.80

273.30

307.40

316.20 331.70 21.50

119.20

153.30

162.10 177.60

13068Add to items for bricks flooring laid to


herring-bone pattern or diagonally (Raking
or circular cutting, and waste measured

separately)

7.10

Except bricks

lkexzh ,oa Je
Bricks laid bZVfcNh

bZVksa jfgr
Bricks laid bZVfcNh

Flat

On edge

Falt

On edge

likV

[kMh

likV

[kMh

Rs.

Rs.

Rs.

21.20

6.70

11.20

13069 Raking or circular cutting


and waste on brick Rs.

flooring
14.20

Rs.
6.30

13063
13063iqjkus uki dh miJs.kh ch
dh bZVas Q'kZ esa likV fcNkuk

13064
13064lc en 1845 ls leku ijUrq
bZVksa ds vykok
1 3065
3065iqjkus uki dh miJs.kh ch dh
bZVksa ds Q'kZ ij [kM+h yxkuk
13066
13066mi;qZDr] ijUrq ekMwyj bZVksa
lfgr
13067
13067mi;qZDr] fdUrq bZV jfgr

13068
13068tksMsa bZVksa ds Q'kZ dh enksa esa lh/kh [kM+h ;k likV
fcNkdj Q'kZ fuekZ.k esa lh/kh ;k xksy dVkbZ o Nhtu
izFkd eisxh

Rs.

M&L

PER RUNNING METRE

izfr oxZ ehVj

Add if,
sub
classA
bricks
are
used

iz f r ehVj

13069
13069frjNh ;k xksy dVkbZ o Nhtu bZV
ds Q'kZ fuekZ.k ij

268

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
FLOOR AND WALL TILING

Q'kZ vkSj nhokj ij Vkby yxkuk


(a) The rates are exclusive of bedding layer or screeded surface
but include for setting and jointing the tiles in cement
paste or slurry.
(b) The rates include for all straight cutting and waste. Raking
or circular cutting and waste shall be measured separately.

;g njsa ijr ;k iVV~h fcNh lrgksa ds jfgr gSa fdUrq Vkbyksa


dks fcBkuk o lhesaV ?kksy ;k lysjh ls tksMuk 'kkfey gSA

[k

bu njksa esa lh/kh dVkbZ o Nhtu 'kkfey gSA frjNh ;k xksy


dVkbZ izFkd ekih tk;sxhA

(c) The rates for glazed tiles and terrazzo tiles include for
laying to any pattern with one or more colours as directed.

dkafpr o VSjStks Vkbyksa dh njksa esa] funsZf'kr ,d ;k vf/kd


jax o fdlh Hkh rjhds esa fcNkuk 'kkfey gSA

(d) The rates for cement concrete and terrazzo tile include for
cutting and polishing.

?k

(e) Wax polishing to terrazzo tile floors, etc. shall be paid


under item 13058

M-

lhesaV dahV o VSjStks Vkbyksa dh njksa esa dVkbZ o ikfy'k


djuk 'kkfey gSA
VSjStks Vkby Q'kZ vkfn ij ekse ikfy'k dk Hkqxrku en
13058 ds varxZr gksxkA

(f) If tiles of different sizes are used then no price adjustment


shall be done.

GLAZED TILES
PER SQUARE METRE
13070 Glazed earthenware tiles
149mmx 149mm (or
152.4mm x 152.4 mm) x
6mm thick, in floors, etc,
set and jointed in neat
cement slurry and
pointed in white or
coloured cement to

match
13071 Add to above for work on
vertical surfaces such as
skirtings, dados and

risers to steps etc.


13072 Ditto as per item 13070 but
size of tile 108mm x
108mm x 4-5mm thick.
13073 Add to above for work on
vertical surface such as
skirtings, dado, and

risers to steps etc.

White tiles

Coloured tiles

Except tiles

lQsn Vkby

jaxhu Vkby

Vkby jfgr

Rs.

Rs.

Rs.

470.50

574.30

272.50

dka f pr Vkbys a
izfr oxZ ehVj
13070 feh dkafpr Vkbysa 149X149
feeh- ;k 152-4X152-4 feeh- X
6 feeh- eksVh Q'kZ vkfn esa] 'kq)
lhesaV ds ?kksy ls fcNh o tqM+h
o lQsn ;k feyrs jax ds lhesVa
ls Vhi dh gqbZ

13071 mi;qZDr esa tksMs+a] [kM+h lrg


dk;Z tSls xksVu MkMksa o lhf<+;ksa
ds ik;nkuksa vkfn

44.20

44.20

44.20

546.30

657.10

272.50

13072 mi;qDZ r en 13070 leku ysfdu


VkbYk eki 108X108 feeh- X
4&5 feeh- eksVh

44.20

13073 tksMsa+ mi;qZDr [kMh lrgksa tSls


xksVu] MkMksa o lhf<+;ksa ds ik;nku
vkfn

44.20

44.20

269

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
FLOOR AND WALL TILING - Contd...

Q'kZ vkSj nhokj ij Vkby yxkuk - tkjh


GLAZED TILES
PER SQUARE METRE
13074 Glazed ceramic tiles
(200x200mm) x 7mm
thick, in floors etc. set and
jointed in neat cement
slurry and pointed in
white or coloured

cement to match
13075 Add to above for work on
vertical surfaces such
as skirting, dados and

risers to steps etc.


13076 Ditto as per item 13074
but
size
of
tile
200x100x7mm thick
13077 Add to above for work on
vertical surfaces such
as skirtings, dados and

risers to steps etc.


13078 Glazed earthenware
tiles 200mmx 100mm x
6mm thick, in floors, etc,
set and jointed in neat
cement slurry and
pointed in white or
coloured cement to match

13079 Add to above for work on


vertical surfaces such as
skirtings, dados and

risers to steps etc.


13080 Glazed ceramic tiles in
vertical surface 300x
200x 7 mm thick set and
jointed in neat cement
slurry and pointed in
white or colour cement to

match

White tiles

Coloured tiles

Except tiles

lQsn Vkby

jaxhu Vkby

Vkby jfgr

Rs.

Rs.

Rs.

dka f pr Vkbys a
izfr oxZ ehVj
1 3074

434.10

520.40

272.50

13075

44.20

44.20

44.20

465.60

569.50

272.50

13076

13077

44.20

44.20

44.20

13078

505.00

607.20

270.00

13079
44.20

44.20

44.20

491.50

592.30

315.50

dkafpr feh Vkbysa 200X200


feeh- X 7 feeh- eksVh Q'kkZsa
vkfn esa yXkh o 'kq} lhesaV
lysjh o feyku ds lQsn
lhesaV ls Vhi dh gqbZ

tksMsa mij dh en esa [kM+h


lrgksa tSls xksVu] MkMksa o
lh<h iknksa ds mBkoksa vkfn
ds dk;Z ij
mi;qZDr 13074 Mh tSlk
fdUrq 200X 100X 7 feeh eksVs
vkdkj dh Vkby
tksMsa+ ij dh en eas] [kMh
lrgksa tSls xksVu] MkMksa o
lh<+h iknksa ds mBkoksa ds dk;Z
gsrq vkfn
feh dkafpr Vkbysa 200X100
feeh- X 6 feeh- eksVh Q'kZ
vkfn es]a 'kq) lhesVa ds ?kksy
ls fcNh o tqMh+ o lQsn ;k
feyrs jax ds lhesaV ls Vhi
dh gqbZ
mi;qZDr esa tksM]+as [kM+h lrg
dk;Z tSls xksVu MkMksa o
lhf<+;ksa ds ik;nkuksa vkfn

270

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
FLOOR AND WALL TILING - Contd...

Q'kZ vkSj nhokj ij Vkby yxkuk - tkjh


GLAZED TILES IN VERTICAL
SURFACE
PER SQUARE METRE
13081 Glazed ceramic tiles in
vertical surface 350x 250x 7
mm/ 450X 350X 7mm thick
set and jointed in neat
cement slurry and pointed
in white or colour cement to

match

White tiles

Coloured tiles

Except tiles

lQsn Vkby

jaxhu Vkby

Vkby jfgr

Rs.

Rs.

Rs.

514.30

615.90

315.50

506.90

605.30

272.50

531.60

636.10

272.50

562.70

661.00

270.50

24.70

24.70

24.70

NON - SKID TILES


13082 Non - skid Ceramic tiles 7 to
8 mm thick (square/
rectangular) area of each tile
exceeding 0.06 sqm but not
exceeding 0.11 sqm, in
floors etc. set and jointed in
neat cement slurry and
pointed in white or coloured

cement to match
13083 Non - skid Ceramic tiles 7 to
8 mm thick (square/
rectangular) area of each tile
exceeding 0.11 sqm but not
exceeding 0.18 sqm, in
floors etc. set and jointed in
neat cement slurry and
pointed in white or coloured

cement to match
13084 Non - skid Ceramic tiles 7 to
8 mm thick area of each tile
exceeding 0.18 sqm but not
exceeding 0.38 sqm, in
floors etc. set and jointed in
neat cement slurry and
pointed in white or coloured

cement to match
13085 Add to rates for item no
13080 to 13084 for joint free
non skid tiles.

271

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
FLOOR AND WALL TILING - Contd...
Q'kZ vkSj nhokj ij Vkby yxkuk - tkjh
VITRIFIED TILES

13086 Virified Ceramic tiles 10 mm


thick (square/ rectangular)
polished, area of each tiles
not exceeding 0.36 sqm, in
floors etc. set and jointed in
neat cement slurry and
pointed in white or coloured

cement to match
13087 Virified Ceramic tiles 10 mm
thick (square/ rectangular)
polished, area of each tiles
not exceeding 0.36 sqm but
not exceeding 0.42 sqm, in
floors etc. set and jointed in
neat cement slurry and
pointed in white or coloured
cement to match

13088 Virified Ceramic tiles light


shade 10 mm thick (square/
rectangular) polished, area of
each tiles not exceeding 0.42
sqm but not exceeding 1.00
sqm, in floors etc. set and
jointed in neat cement slurry
and pointed in white or
coloured cement to match
PER RUNNING METRE
13089 Raking, cutting and waste on

glazed tiles
13090 Circular cutting or notching
and waste on glazed tiles

Light
Shade
Rs.

Dark
Shade
Rs.

Except
tiles
Rs.

817.10

1086.40

272.50

Light
Shade

Dark
Shade/Do uble
charged/
ultracharged

Except

Rs.

Rs.

Rs.

821.70

1203.90

272.50

1265.60

1574.00

272.50

M&L

Except tiles

lkexzh ,ao Je

Vkby jfgr

Rs.

Rs.

71.00

55.50

143.60

108.40

Rs.

EACH
13091 Boring holes through glazed
tile lining for pipes, etc n exc
50mm dia and making good

4.80

iz f r ehVj
13089
13089dafpr Vkbyksa ij drjkbZ] dVkbZ
o Nhtu
13090
13090dafpr Vkbyksa dh xksy dVkbZ ;k
drjkbZ o Nhtu

iz R ;s d
13091
13091ikbi vkfn ds fy, dkafpr Vkbyksa
dh iafDr;ksa esa vuf/kd O;kl ds
Nsn fudkyuk o mUgsa Bhd djuk
vkfn

272

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
FLOOR AND WALL TILING-Contd...
Q'kZ vkSj nhokj ij Vkby yxkuk tkjh
CEMENT CONCRETE AND TERRAZZO TILES
lhesaV dahV vkSj rjStks Vkbysa
PER SQUARE METRE With grey With grey With mixture With white
cement
cement of white & grey cement &
and no
and pigcement in
pigment
13092Cement concrete pigment
ments
equal prolQsn lheasV
tiles 20cm x 20cm
Hkwjs lheasV Hkwjs lheasV portions & no
ds lkFk
x 20mm thick,
vkS
j
ja
x
ghu
ds
lkFk
pigments
vkS
j jaxhu
m a c h i n e
vkSj jaxhu lQsn vkSj Hkwjs
pressed;
set
jointed
and
lhesaV ds cjkcj ds
pointed in neat
feykc esa jaxghu
cement slurry in
Rs.
Rs.
Rs.
Rs.
floors, and cut
503.60
518.60
592.80
667.50

and polished
13093Ditto. tiles, 25cm
x 25cm x 22mm
thick, ditto
431.10
440.60
509.30
597.50
13094Terrazzo tiles
20cm x 20 cm x
20mm thick, with
size of chips upto
6 mm; set jointed
and pointed in
neat cement slurry
in floors, and cut

and polished
608.10
629.00
765.90
846.60
13095Ditto, tiles 25cm
x 25cm x 22mm
535.20
550.30
651.20
728.10

thick. Ditto
13096Terrazzo tiles
20cm x 20cm x
20mm thick, with
size of chips upto
12mm;
set,
jointed
and
pointed in neat
cement slurry in
floors, and cut
and polished
13097Ditto,
tiles
25cm x 25cm x
22 mm thick,

ditto

646.90

667.80

801.70

882.40

561.70

601.40

660.70

737.50

Except
tiles

Vkby
jfgr

izfr oxZ ehVj

13092
13092lhesaV dahVdh 20 lss-eh- X
20 lsa-eh- X 20 feeh- eksVh
e'khu laihfMr 'kq} lhesVa ds
?kksy esa Q'kZ esa fcBkuk] tksMu+ k
vkSj dVkbZ iksfy'k djuk

Rs.
279.80

13093
13093mi;qZDr] Vkby 25 lsa-eh- X
25 lsaeh- o 22 feeh- eksVh]
279.80
mi;qZDr
13094
13094VSjStksa Vkbysa 20 las-eh- X 20
lsa-eh- X 20 feeh- eksVh] 6
feeh- ds nkus lfgr Q'kZ esa
'kq} lhesaV esa fcBkuk o
tksM+uk] rFkk dVkbZ vkSj
ikfyl djuk

279.80

13095
13095mi;qZDr] Vkby 25 lsaeh X
25 ls a e h o 22 feeh]
279.80
mi;qZDr
13096
13096VSjStks VkbZy 20 lsaeh X 20
lsaeh o 20 feeh eksVh] 12
feeh vkdkj rd ds nkus
lfgr] 'kq} lhesVa ds ?kksy esa
Q'kZ fcNkuk vkSj tksMu+ k rFkk
dVkbZ vkSj ikfy'k djuk
279.80

13097
13097mi;qZDr] Vkbysa 25 lsaeh X
25 lsaeh o 22 feeh eksVh]

mi;qZDr
279.80

273

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
FLOOR AND WALL TILING-Contd...
Q'kZ vkSj nhokj ij Vkby yxkuk tkjh
CEMENT CONCRETE AND TERRAZZO TILES-Contd...
lhesaV dahV vkSj VSjstks Vkbysa tkjh
PER SQUARE METRE
13098 Machine pressed precast
conctete interlocking paver
block any shape and size
confirming to IS 15658-2006
of 60 mm thickness, M-35

Grade
13099 Machine pressed precast
conctete interlocking paver
block any shape and size
confirming to IS 15658-2006
of 80 mm thickness M-40

Grade
13100 Machine pressed precast
conctete interlocking paver
block any shape and size
confirming to IS 15658-2006
of 100 mm thickness M-50

Grade

With Grey
Cement
and no
pigment

With Grey
Cement
and
pigment

Except
tiles

498.40

516.60

74.80

553.90

578.10

94.00

622.30

652.50

107.90

Rs.
13101 Terrazzo tiles with bullnosed
edge 32 cm x 20 cm x 40 mm
thick, set, jointed and pointed
in neat cement slurry as in
treads, and cut polished 742.50
13102 Chequered cement concrete
tiles 20cm x 20cm x 25mm thick,
set, jointed and pointed in neat
513.00
cement slurry in floors
13103 Ditto, but bullnosed 32cm x
19.85cm x 30mm thick as in
514.10
treads
13104 Add to items 13092 to 13097
for work on vertical surfaces
as in skirtings, dados and
56.20
risers of steps

Rs.

Rs.

izfr oxZ ehVj

Rs.

Rs.

762.70

852.30 881.80

285.90

527.90

602.10 691.80

281.70

534.30

603.70 683.80

281.70

56.20

56.20

56.20

56.20

13101
13101cM+sa uqdhys fdukjs okyh VSjStks
Vkbysa 32lsea h X 32lsea h X 40feeh
eksVh 'kq} lhesaV ?kksy ls iknksa esa
fcBkuk vkSj tksM+uk rFkk dVkbZ
vkSj ikfyl djuk
13102
13102lhesVa dahVdh pkj[kkus dh jaxfojaxh
Vkbys]a 20 lsea h- X 20 lsea h- o 25
feeh eksVh 'kq} lhesVa ?kksy esa Q'kZ esa
fcBkuk tksMu
+ k vkSj Vhi djuk
13103
13103mi;qZDr] ysfdu mHkkjh 32 X 1985 ls-eh- o 30 feeh- eksVh] iknksa
es a
13104
13104tksM]as+ en 13092ls 13097 es]a [kM+h
lrg tSl]s uhps ds fdukjs nhokj
ds fupys Hkkx vkSj lh<+h ds inksa
ds mBko gsrq

ACID RESISTANT TILES


vEy izfrjks/kh Vkbysa
PER SQUARE METRE

M&L

13105Acid resistant tiles 15mm thick


vitreous ceramic, unglazed, set,
jointed and pointed in chemical
resistant mortar, resin type, in

floors

lkexzh ,ao
Je
Rs.
1250.50

Except
tiles

Rs.
762.60

izfr oxZ ehVj


13105

vEy izfrjks/kh dkapk; jaxghu Vkbys]a


jky leku] jklk;fud izfrjks/kh
elkys esa Q'kZ esa esa cBkuk] tksM+uk
vkSj Vhi djuk

274

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
FLOOR AND WALL TILING-Contd...
Q'kZ vkSj nhokj ij Vkby yxkuk tkjh

PER RUNNING METRE

13106 Raking, cutting and


waste
on
any
thickness and size of

tiles
13107 Circular cutting or
notching and waste
on any thickness and

size of tiles

Cement concrete tiles

Terrazzo
tiles

lhesVa
dahV Vkbysa

rjStks Vkbysa

Rs.

Rs.

Rs.

Rs.

82.80

96.90

128.70

47.60

144.80

Acid
resistant
tiles

Vkby jfgr

vEy jks/kd
Vkbysa

173.00

236.40

iz f r ehVj

Except tiles

74.30

13106 fdlh Hkh eksVkbZ ;k eki dh


Vkbyksa ij [kqjpuk] dkVuk o
Nhtu
13107 xksy o nkarns kj dVkbZ o Nhtu
fdlh Hkh ?kuRo vkSj eki dh
Vkbyksa ij

REPAIRS TO FLOOR AND WALL TILING


Q'kZ vkSj nhokj dh Vkbyksa dh ejEer
(a) The rates include for cutting out broken tiles, removing
and cleaning loose tiles, preparing bed removing rubbish,
removing and replacing old with new tiles to match,
complete with all cuttings, etc. that may be required. New
tiles required to supplement old ones shall be paid for at
supplied only rates.

d bu njksa esa VwVh Vkbyksa dks dkV fudkyuk] <hyh Vkbyksa dks
fudkyuk vkSj lkQ djuk] dpjk gVkdj lrg cukuk] iqjkuh
dks leku ubZ ls cnyuk] lHkh dVkbZ vkfn tSlk fu#ifr gks
}kjk iw.kZ djuk lfUufgr gSA iqjkuh Vkbyksa dk LFkku ysus ds
fy, ftruh ubZ Vkbysa yxsaxh mudk Hkqxrku dsoy vkiwfrZ dh
njksa ij gksxkA

(b) Repairs to floor hearth, or wall tiling exceeding 5sq.m in


each patch shall be paid for at the rates for new work
(portions in which old tiles are used shall be paid at except
tiles rate).

[k Q'kZ ry ;k nhokj esa Vkbyksa ds dk;Z esa 5 oxZ eh- ls cM+as izR;sd
VqdM+s dk Hkqxrku uohu dk;Z ekudj gksxkA og Hkkx tgka
iqjkuh Vkbysa iz;ksx dh xbZ gS mldk *Vkby jfgr* dh nj ij
Hkqxrku gksxkA
x ;fn ,d nwljs ds vfr ikl okys isouksa dk ewY; ml iwjs {ks=
ftlesa ,sls VqdM+s vkrs gSa vkSj muds chp dk LFkku feykdj]
vf/kd vkrk gks rks ,sls leLr {ks= dks gh u;k fd;k tk;sxk rFkk
mi;qZDr enksa ds vUrxZr ns; gksxk( lkcqr Vkbyksa dks nqckjk
yxk;k tk;sxk vkSj og {ks= tgka ,slh Vkbysa iz;Dq r gqbZ gaS ekik
tk;sxk vkSj *Vkby jfgr* dh nj ij Hkqxrku gksxkA

(c) If payment for patches close to each other exceed the


payment for renewing the whole area consisting of such
patches and sound portions in between them, then the whole
of such area shall be renewed and paid for under the
appropriate items; the sound tiles being reused and area
using such tiles measured and paid for at except tile rate.

275

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
REPAIRS TO FLOOR AND WALL TILING-Contd...
Q'kZ vkSj nhokj dh Vkbyksa dh ejEer
ejEer-tkjh
PER SQUARE METRE
13108 Renewing tiles in patches, area
n exc 5 sq.m. including
removing and cleaning old
tiles, preparing beds and laying
or setting, jointing and pointing
new or old tiles complete

Glazed tiles Cement condkafpr Vkbysa crete tiles

lhesaV dahVdh
Vkbysa
Rs.

Rs.

409.00

321.70

13108 5 o-eh- vuf/kd ds VqdM+ksa esa Vkby


nksckjk yxkus esa iqjkuh Vkbyksa dks gVkuk
vkSj lkQ djuk] /kjkry rS;kj djuk]
Rs.
vkSj iqjkuh ;k ubZ Vkbyksa dks fcNkuk ;k
321.70
fcBkuk] tksMu
+ k vkSj Vhi djds iw.kZ djuk
rjStks
Vkbysa

Rs.

13109 Dismantling floor, hearth or


wall tiling including cement
mortar bedding (but not
backing), removing serviceable
tiles to store and rubbish off the

premises

izfr oxZ ehVj

Terrazzo
tiles

13109 Q'kZ] dqUM ;k nhokj ls Vkbysa fcNs gq;s


lhesaV elkys lfgr m[kkM+uk mi;ksxh
Vkbyksa dks Hk.Mkj esa tek djuk vkSj
ml ifjlj ls eyck gVkuk

29.20

DAMP PROOF COURSES


lhyu fujks / kd mik;
The rates for polythene film include for laps, and work in all positions and in narrow widths.

ikfyfFku f>Yyh dh njksa esa mHkkjksa o lHkh vkLFkkuksa o ladjh pkSM+kbZ;ksa esa dk;Z lfUufgr gSA
PER SQUARE METRE
13110 Bitumen blown any grade, applied hot,
two coats, to concrete surfaces at the rate

of 1.5kg. per sq. m per coat


13111 Polythene film, black, 50micron laid in

floors

Rs.

132.30
14.20

izfr oxZ ehVj


13110 Qqd
a k rkjdksy dksbZ Js.kh dks xeZ djds dahVdh rg
ij nks ijrksa esa 1-5 fdxzk izfr oxZeh izfr ijr fcNkuk
13111 ikyhFkhu f>yh] dkyh] 50 ekbks u Q'kZ ij
fcNkuk

276

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
LINOLEUM COVERING TO FLOORS ETC.
Q'kZ vkfn ij fyuksfye pknj fcNkuk
Rates include for all cutting and waste and work in all positions and in narrow widths.

njksa esa dVkbZ vkSj fu'ks"k rFkk lHkh voLFkkvksa esa vkSj ladh.kZ pkSM+kbZ esa dk;Z 'kkfey gSA
izfr oxZ ehVj

PER SQUARE METRE


Thickness in mm

eksVkbZ feeh esa


13112Linoleum, plain coloured, laid
dry in floors including
stretching, cutting and fitting

13113Ditto, but except linoleum


13114Add to last two items if linoleum
is sealed down with an approved

adhesive

2.00

3.20/3.30

4.50

Rs.
389.90
37.40

Rs.
453.10
41.80

Rs.
574.90
46.20

13112 fyuksfy;e] lk/kk jaxhu /kjkry ij lw[kk


fcNkuk] QSykuk] drjuk o cSBkuk
13113 mi;qZDr] ysfdu fcuk fyuksfy;e

67.10

67.10

13114 vafre nks enksa esa tksMsa ;fn fyuksfy;e


fdlh Lohd`r yslnkj inkFkksZ esa fHkxksdj
67.10
fpidk;k gks

RUBBER SHEET AND TILE FLOORING


jcM+ pknj vkSj Vkby dk Q'kZ fcNkuk
Rates include for all cutting and waste and work in all positions as well in narrow widths.

njksa esa dVkbZ vkSj fu'ks"k rFkk lHkh voLFkkvksa esa vkSj ladh.kZ pkSM+kbZ esa dk;Z 'kkfey gSA
PER SQUARE METRE

M&L

Except rubber
tiles/sheet

lkexzh ,oa Je

izfr oxZ ehVj

joM+ VkbZy@
pknj jfgr
13115 Rubber sheet with fabric
backing or insert and plain
coloured or marbled
topping, matt or glossy, laid
in floors with approved

adhesive

Thickness in mm

eksVkbZ feeh esa


2.5

3.5

5.0

Rs.

Rs.

Rs.

Rs.

747.50

806.30

829.84

101.30

13116 Ditto, but with ribbed or

fluted topping

782.80

853.30

876.80

101.30

13117 Rubber tiles with fabric


backing or insert, plain
coloured or marbled
topping, matt or glossy, laid
in floors with approved

adhesive

640.80

699.50

746.50

112.00

13115
13115jcM+ dh 'khV] diMk iz"B ;k
funsZf'kr vkSj lkns jaxokyh ;k
laxejejh 'kh"kZ okyh] fprdcjh
;k pedhyh] Lohd`r ysl lfgr
Q'kZ esa fcNh gqbZ
13116
13116mi;qDZ r] fdUrq /kkjhnkj ;k uyhnkj
'kh"kZ okyh
13117
13117jcM+ VkbZyas diM+k iz"B ;k fuosf'kr
lkns jaxokyh ;k laxejejh 'kh"kZ
okyh] fprdcjh ;k pedhyh
Lohd`r ysl lfgr Q'kZ esa yxkuk

277

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
RUBBER SHEET AND TILE FLOORING-Contd...
jcM+ pknj vkSj Vkby ds Q'kZ fcNkuk
fcNkuk-tkjh
PER SQUARE METRE

Rs.

Rs.

Rs.

Rs.

izfr oxZ ehVj

13118Ditto, with ribbed or fluted

topping

676.00

737.80

793.50

112.00

13118 mi;qZDr] fdUrq /kkjhnkj ;k


uyhnkj 'kh"kZokyh

PVC SHEET AND TILE FLOORING


ih oh lh lhV vkSj Vkby ds Q'kZ fcNkuk
Rates include for all cutting and waste and work in all positions
as well as in narrow widths.

bu njksa esa lHkh izdkj dh dVkbZ rFkk Nhtu rFkk Nhtu vkSj lHkh
voLFkkvksa ;gka rd fd ladh.kZ pkSM+kbZ esa dk;Z 'kkfey gSA

PER SQUARE METRE


Thickness in mm

Except
PVC
sheets
or tiles

eksVkbZ feeh esa

13119PVC tiles/ sheets,


laminated
plain
coloured,
marbled
mosaic
or mottled 1.50
finish, laid with apRs.
proved
rubber based
684.60
adhesive in floors
13120PVC tilesditto but

homogeneous
691.80
13121PVC asbestos tiles, plain
coloured or mottled
finish;
laid
with
approved bituminous
604.40
adhesive in floors
13122Ditto,
laid
with
approved
synthetic
adhesive in vertical
651.40
surfaces

2.00

2.50

3.00

Rs.

Rs.

Rs.

661.10 743.30

802.10

izfr oxZ ehVj

ihohlh
13119ihohlh Vkbys@
a pknjsa ijr
pknj ;k 13119
p<+ h ] lknk ja x okyh
Vkby jfgr
laxejejh eqtkfed ;k
4.00
fprdojh] jcM+ ds Lohd`r
Rs.
Rs.
ysl lfgr Q'kZ esa fcNh
860.80

97.10

750.60 780.00

809.30

868.10 104.30

627.90 674.90

733.70

792.40

87.40

627.90 674.90

733.70

792.40

87.40

13120
13120ihohlh Vkbysa mi;qZDr
fdUrq le:ih
13121
13121ihohlh vng Vkbysa] lkns
jaxokyh ;k fprdcjh]
Lohd`r jky ls rj djds
Q'kZ esa fcNh
13122
13122mi;qZDr]
Lohd`r
jklk;fud ?kksy esa [kM+h
lrg ij fcNh

278

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaM+ts yxkuk
MATERIALS (SUPPLIED ONLY)
lkexzh dsoy vkiwfkZ
PER SQUARE METRE

izfr oxZ ehVj

Thickness in mm

eksVkbZ feeh esa


25

30

40

Rs.

Rs.

Rs.
13123 Rough dressed sand stone slabs 94.00

105.70 129.20

105.70
13124 Rough dressed lime stone slabs

117.50 164.50

PER CUBIC METRE

Rs.

13125 Quarried stone for dry paving (measured in


tightly packed stacks)

499.40

13123
13123eksVs rkSj ij x<+h] ckyqbZ iRFkj dh if;k

13124eksVs rkSj ij x<+h] iRFkj dh if;k


13124

izfr ?ku ehVj


13125
13125[kku ds iRFkj lw[ks fcNkus ds fy, lVs pV~Vksa esa ekis
tk;sx
a s
izfr 50 fdxzk cksjh

PER 50 KG. BAG


13126White portland cement in jute bags or other
packing
PER KILOGRAM

13127 Pigments for use with cement

705.00

13126
13126lQsn leqnzh lhesaV twV ds cksjs ;k vU; xBjh esa

Red oxide of
iron, carbon
black

Green
chromium
oxide, yellow
oxide of iron

/kkrq dkcZu ;qDr


yky tkj.k
rRo

tLrh gjk tkj.k


rRo

Rs.

Rs.

58.70

64.60

izfr fdyks xzke

13127
13127jax nzO; lhesV esa iz;ksx ds fy,

13128 Carborundom powder, 80 grit

29.40

izfr fdyks xzke


13128
13128dkcZu pw.kZ 80 va'k

13129 Oxalic acid

82.20

13129
13129xeZ /kkrq

293.70

13130
13130ekse Q'kZ ij ikfyl ds fy,

PER KILOGRAM

Rs.

13130 Wax for floor polish

iz f r fDoa V y

PER QUINTAL

13131 Marble chips 2 to 15mm (any size and colour)

728.50

13131
13131laxejejh nkus 2 ls 15 feeh fdlh vkdkj ;k jax esa

279

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaMts yxkuk
MATERIALS (SUPPLIED ONLY)Contd...
lkexzh dsoy vkiwfkZ tkjh

35.20

iz f r yhVj
13132
13132lksMh;e vkSj vfXu izLrj dk feJ.k ?kuRo 84 ifjek.k
fn[kkch fof'k"V eki 1-42 vkisf{kr ?kUkRo

411.20

izfr /ku ehVj


13133
13133eksVk feykok vleku Q'kZ ds fy, 12-5 feeh ls
4-75 feeh rd

Rs.

PER LITRE
13132 Sodium silicate, density 84 degress
twaddell (specific gravity 1.42)

PER CUBIC METRE


13133 Coarse aggregate for granolithic floors

graded from 12.5mm to 4.75mm

PER KILOGRAM

13134 Bitumen, blown type, 85/25 grade


13135 Bituminous compound for water-proofing

and caulking purposes

38.20
47.00
20.00

13136 Polythene sheet, black. 50 micron

PER SQUARE METRE

izfr fdyks xzke


13134 jky Qqadh fdLEk dh 85@25 Js.kh
13135 jky dk ?kksy] ty fujks/k vkSj njkj HkjkbZ ds fy,

13136 ikyhFkhu 'khV] dkyh 50 ekbksu

izfr oxZ ehVj

Thickness in mm

eksVkbZ feeh esa


2.0

3.2/3.3

4.5

13137 Linoleum, plain coloured type

Rs.

Rs.

Rs.

352.50

411.20

528.70

13138 Linoleum, moire type

376.00

470.00

611.00

13139 Linoleum, jaspe type

387.70

470.00

587.50

13140 Linoleum, marble type

411.20

493.50

611.00

13138
13138fyuksfy;e] ek;j fdLe dh
13139
13139fyuksfy;e] tLih fdLe dh
13140
13140fyuksfy;e] laxejej fdLe dh

PER LITRE

Rs.

13141Approved adhesive for setting linoleum

141.00

PER SQUARE METRE

13137
13137fyuksfy;e] lkns fdLe dh

iz f r yhVj
13141
13141Lohd`r rjy] fyuksfy;e fcBkus ds fy,
izfr oxZ ehVj

Thickness in mm

eksVkbZ feeh esa


2.5

3.5

5.0

Rs.

Rs.

Rs.

13142Rubber tiles with fabric backing or


insert, plain coloured or with marbled
finish

13143Ditto, with ribbed or fluted topping

528.70 587.50 634.50

13144Rubber sheet with fabric backing or


insert, plain coloured or with marbled

finish
13145Ditto, with ribbed or fluted topping

646.20 705.00 728.50

564.00 622.70 681.50

681.50 752.00 775.50

13142
13142jcM+ Vkby diM+k i`"B ;k fuosf'kr] lkns
jaxokyh ;k laxejejh iwfkZ lfgr

13143
13143mi;qDZ r] fdUrq /kkjhnkj ;k uyhnkj 'kh"kZokyh
13144
13144jcM+ 'khV] diM+k i`"B ;k fuosf'kr] lkns
jaxokyh ;k laxejejh iwfrZ lfgr

13145
13145mi;qDZ r] fdUrq /kkjhnkj ;k uyhnkj 'kh"kZokyh

280

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaMts yxkuk
MATERIALS (SUPPLIED ONLY)Contd...
lkexzh dsoy vkiwfkZtkjh
PER LITRE

Rs.

13146 Approved adhesive for setting rubber

tiles or sheeting

152.70

PER 100 NOS.


13147 Stone setts 200 to 250 mm long, 150 to

200mm wide and 150mm deep


13148 Edge stones 250 to 300mm long, 150 to

200mm wide and 450mm deep

881.20
1762.50

PER KILOGRAM
13149 Metallic floor hardener

PER 100 NOS.


13150 Glazed earthenware tiles 149 x
149 mm (or 152.4 x 152.4 mm) and

6 mm thick
13151 Glazed earthen ware tiles l08x

108mm x 4-5mm thick


13152 Glazed ceramic tiles 200 x 200mm

x 7mm thick
13153 Glazed ceramic tiles 200x100

x7mm thick
13154 Glazed earthenware tiles 200 x

100 mm x 6 mm thick
13155 Non Skid Ceramic tile 300x300

x 7 mm thick

17.60

iz f r yhVj
13146
13146Lohd`r rjy jcM+ Vkby ;k 'khV fcBkus ds fy,

izfr 100 la[;k


13147
13147iRFkj ds pkSds 200 ls 250 feeh yEcs 150 ls 200
feeh pkSM+s vkSj 150 feeh xgjs
13148
13148fdukjh iRFkj 250 ls 300 feeh yEcs 150 ls 200
feeh pkSM+s vkSj 450 feeh xgjs
izfr fdyksxzke
13149/kkrqbZ Q'kZ nqcs/;
13149

White

Coloured

lQsn

jaxhu

Rs.

Rs.

440.60

517.20

317.20

340.70

646.20

705.00

317.10

406.50

470.20

493.50

2115.20

2350.00

izfr 100 la[;k


13150
13150dkafpr feh ls cuh Vkbysa 149X149 feeh
;k 152-4 X 152-4 feeh vkSj 6 feeh eksVh

13151
13151dkafpr feh Vkbysa 108 X 108 X 4 -5 feeh
eksVh
13152
13152dkafpr vkMEcjh Vkbysa 200 X 200 X 7
feeh eksVh
13153
13153dkafpr vkMEcjh Vkbysa 200 X 100 X 7
feeh eksVh
13154
13154dkafpr feh ls cuh Vkbysa 200X 100 feeh
vkSj 6 feeh eksVh
13155
13155fQlyu jfgr vkMEcjh Vkbysa 300 X 300
X 7 feeh eksVh

281

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaMts yxkuk
MATERIALS (SUPPLIED ONLY)Contd...
lkexzh dsoy vkiwfkZ tkjh
PER 100 Nos.

13156 Cement concrete tiles 20cm


x 20cm x 20mm thick
13157 Ditto, 25 cm x 25 cm x 22

mm thick
13158 Chequered cement concrete tiles 20cm x 20cm x

25mm thick
13159 Ditto, bullnosed, 32cm x
20cm x 30mm thick

Hkwjs o lQsn
lhesaV ds
cjkcj ds
feyko esa
jaxghu

lhesaV esa
jaxhu

Rs.

Rs.

Rs.

Rs

881.20

940.00

998.70

1057.50

940.00

998.70

1057.50

1175.00

910.60

969.40

1028.10

1145.60

1351.20

1468.70

1527.50

1645.00

1292.50
1445.20

1374.70
1527.50

1680.20
1821.20

1762.50
1903.50

13159
13159mi;qZDr] fdukjksa okyh 32lseh- X
20lseh- X 30 feeh- eksVh
13160
13160VSjt
s ks Vkby 20lseh- X 20lseh- X
20 feeh- eksVh 6 feeh drju
lfgr
13161
13161mi;qZDr] 12 feeh drju lfgr

13160 Terrazzo tiles 20cm x


20cm x 20mm thick with

chips upto 6mm


13161 Ditto, with chips upto 12

mm
13162 Terrazzo tiles 25cm x 25cm
x 22mm thick with chips

upto 6mm
13163 Ditto, with chips upto
12mm

13164 Terrazzo tiles with


bullnosed edge, 32cm
x 20cm x 40mm thick

izfr 100 la[;k

With grey With grey With mixture With


cement
cement of white &
white
and no
and
grey cement cement
pigment pigment in equal pro&
Hkwjs lhesaV Hkwjs lhesaV portions & pigments
esa jaxghu esa jaxhu no pigment
lQsn

13156
13156lhesVa dahVdh Vkbysa 20 lseh X 20lseh- X 20 feeh- eksVh
13157
13157mi;qZDr] 25lseh- X 25lseh- X 22
feeh- eksVh
13158
13158psdMZ lhesaV dahV dh Vkbysa
20lseh- X 20lseh- X 25 feeh- eksVh

1586.20

1680.20

1938.70

2044.50

13162
13162VSjt
s ks Vkby 25lseh- X 25lseh- X
22feeh eksVh] 6 feeh drju
lfgr

1750.70

1997.50

2044.50

2103.20

13163
13163iwoksZDr 12 feeh rd drju
lfgr

2526.20

13164
13164VSjstks Vkbysa frjNs fdukjs 32X
20lseh X 40 feeh- eksVh

2056.20

2173.70

2350.00

282

SECTION 13

SECTION 13FLOOR FINISHES AND PAVINGS


[k.M 13&Q'kZ ifj"d`fr rFkk [kaMts yxkuk
MATERIALS (SUPPLIED ONLY)Contd...
lkexzh dsoy vkiwfkZ tkjh
PER SQUARE METRE

izfr oxZ ehVj

Thickness in mm

eksVkbZ feeh esa


13165 PVC tiles/sheet, laminated,
plain coloured, marbled,
mosaic or mottled finish
13166 PVC tiles, ditto, but

homogeneous
13167 PVC asbestos tiles, plain

coloured or mottled finish

1.50
Rs.
587.50

587.50
517.00

2.00

2.50

3.00

4.00

Rs.

Rs.

Rs.

Rs.

13165 ihohlh Vkby@'khV ijr p<+]as


lkns ja x okys ] la x ejejh
564.00 646.20 705.00 763.70
eqtkfed ;k /kCcsnkj iwfkZ
13166 ihohlh Vkby] mi;qZDr] fdUrq
le:i
646.20 675.60 705.00 763.70
13167 ihohlh vng Vkby] lknk jaxhu
540.50 587.50 646.20 705.00
;k /kwfey if;k
Rs.

PER LITRE
13168 Rubber based adhesive for PVC or PVC
asbestos sheets and tiles

PER RUNNING METRE

141.00

iz f r YkhVj
13168 jcM+ vk/kkfjr rjy inkFkZ] ihohlh ;k ihohlh vng
'khV vkSj Vkbyksa gsrq

Width of strip in mm

iz f r ehVj

if;ksa dh pkSM+kbZ feeh esa


22

28

38

Rs.
13169 Aluminium dividing strips, 1.5mm
29.40
thick
9.40
13170 Glass dividing strips, 3 mm thick

Rs.

Rs.

35.20

47.00

17.60
13171 Plastic dividing strips, 1.5 mm thick

21.10

11.30

PER LITRE

Rs.

13172 Approved bituminous adhesive for PVC

asbestos tiles
13173 Approved synthetic adhesive for PVC

asbestos tiles

94.00
99.90

13169 vYeksfu;e dh foHkktd if;kW 1-5 feeh


eksVh
15.00 13170 'kh'ks dh foHkktd if;ka 3 feeh eksVh
28.20 13171 IykfLVd dh foHkktd if;ka 1-5 feeh eksVh

iz f r yhVj
13172 vuqeksfnr rkjdksyh ?kksy ih oh lh vng Vkbyks ds fy;s
13173 vuqeksfnr l'ys"k.k ?kksy ih oh lh@ vng Vkbyksa ds
fy;s

283

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
SECTION 14
PLASTERING AND POINTING
[k.M 14 iyLrj vkSj Vhi dk;Z
SPECIAL CONDITIONS
fo'ks"k 'krsZ
14.1 MeasurementsPlastering

14-1

14.1.1 Adjustments

14-1-1 O;oLFkk;s a
d dfM+;ksa /kjuksa o vk/kkjksa vkfn ds fdukjksa vkSj ,sls eks[ks tks
izR;sd 0-5 o-eh- ls vf/kd ugha gSa ds fy, dVkSrh ugha dh
tk;sxh vkSj uk gh dfM+;ksa] /kjuksa] [kEHks vkfn ds fdukjksa ij
iyLrj djus vkSj uk gh eks[kksa ds i[[ks] egjko] if;ksa]
nsgfy;ksa vkfn ds fy, vfrfjDr fn;k tk;sxkA
[k dVkSrh 0-5 o-eh- ls vf/kd o 3 o-eh- ls vuf/kd eks[kksa ds fy,
fuEu izdkj gksxh rFkk i[[kksa] esgjkoksa] if;ksa] nsgfy;ksa vkfn
ds fy, vfrfjDr ns; ugha gksxkA
i tc nhokj ds nksuksa rjQ ,d gh izdkj dk iyLrj fd;k
gks rks dVkSrh dsoy ,d rjQ esa ls gh dh tk;sxhA

(a) No deduction shall be made for ends of joists, beams,


etc.. and openings n exc 0.5 sq. m each and no addition
shall be made for finishing the plaster around ends
of joists, beams, posts, etc. not for the reveals, jambs,
soffits, cills, etc., of the openings.
(b) Deduction for openings exceeding 0.5 sq.m but not
exceeding 3 sq. m shall be made as follows and no
addition shall be made for reveals, jambs, soffits, cills,
etc. of these openings.
(i) When both faces of the wall are plastered with
the same plaster, deduction shall be made for one
face only.
(ii) When two faces of wall are plastered with
different types of plaster or if one face is plastered
and the other pointed, deduction shall be made
from the plaster or pointing on the side of frame
for door, window etc. on which width of reveals
is less than that on the other side but no deduction
shall be made on the other side. Where width of
reveals on both faces of wall are equal, deduction
of 50% of areas of opening on each face shall be
made for areas of plaster and/or pointing as the
case may be.
(iii) When only one face is plastered and the other
face is not having any treatment, full deduction
shall be made from the plaster if the width of
reveals on the plastered side is less than that on
the unplastered side; but if the width of reveals
on both sides are equal or width of reveal on the
plastered side is more, no deduction will be made.
(iv) When width of frame is equal to the thickness of
wall or is projecting beyond the thickness of wall,
full deduction for opening shall be made from
each plastered face of wall.
(c) For openings of area exc 3 sq.m each, deductions shall
be made for the openings and plastering of jambs,
and cills be measured.
Note: In calculating areas of openings, the extra width of
rebated reveals, if any, shall be excluded.

eki iyLrj dk;Z

ii tc nhokj ds nksuksa rjQ fHkUu&fHkUu Js.kh dk iyLrj


gks ;k ,d rjQ iyLrj o nwljh rjQ Vhi] rks nhokj
ds ftl rjQ njoktks f[kM+fd;ksa vkfn dh pkS[kVsa yxh
gksa ftl ij i[[kksadh pkSMkbZ nwljh rjQ dh pkSM+kbZ ls
de gks ml rjQ ds iyLrj vkSj Vhi lsa dVkSrh dh
tk;xh ysfdu nwljh rjQ ls dVkSrh cM+h gksXkhA tgka
nhokj ds nksuks rjQ i[[kks dh pkSM+kbZ leku gks rks
eks[kksa dk {ks=Qy nhokj ds nksuksa rjQ ds {ks=Qy esa ls
gj rjQ 50% dh dVkSrh gksxhA
iii tc ,d rjQ iyLrj fd;k gks vkSj nwljh rjQ dksbZ
mipkj u gks rks ;fn iyLrj okyh rjQ i[[kksa dh
pkSMk+ bZ nwljh rjQ ls de gS rks iyLrj esa ls iwjh dVkSrh
dh tk;sxh] ysfdu ;fn nksuksa rjQ ds i[[kksa dh pkSMk+ bZ
leku gS ;k iyLrj dh rjQ dh pkSMk+ bZ vf/kd gS rks
dVkSrh ugha gksxhA
iv tc pkS[kV dh pkSMk+ bZ] nhokj dh eksVkbZ ds cjkoj gks ;k
nhokj dh eksVkbZ ls ckgj vk jgh gks rks eks[ks dh iwjh
dVkSrh gj rjQ ds iyLrj ls dh tk;sxhA
x ,sls eks[ks ftudk {ks=Qy 3- o- eh- ls vf/kd gks mu eks[kksa dh
dVkSrh dh tk;sxh vkSj /kjfu;ksa vkSj nsgfy;ksa ds iyLrj dks
ekik tk;sxkA
uksV% eks[kksa ds {ks=Qy dh x.kuk esa] c<+s gq, i[[kksa dh vfrfjDr
pkSM+kbZ ;fn dksbZ gS] rks mls NksM+ fn;k tk;sxkA

284

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
SPECIAL CONDITIONS Contd...
fo'ks"k 'krsZ tkjh
14-1-2 iyLrj dh eksVkbZ
d iyLrj dh eksVkbZ] tksMk+ as esa Hkjs elkys dh xgjkbZ dks NksMd
+ j
gksxh] vFkkZr bZV vkSj iRFkj dh fpukbZ esa xM<s vkSj [kqyh lfU/k;ka
vkfn ;k jn~nksa ds chp dk vUrjA
(b) Thickness of plaster shall mean minimum thickness [k iyLrj dh eksVkbZ dk vFkZ gS] lrg ds fdlh Hkh fcUnq ij de ls
at any point on the surface. This does not include
de eksVkbZA blesa lrg dh iksrkbZ dh eksVkbZ 'kkfey ugha gSA
14.1.2 Thickness of Plaster
(a) Thickness of plaster shall be exclusive of the depth of
mortar key in joints, i.e. grooves and open joints in
brickwork, stonework, etc., or space between laths.

thickness of dubbing out.


(c) In the case of dubbing out on old walls, out of plumb;
the thickness shall mean the average thickness
excluding the depth of mortar key in joints.

x lkgqy ls ckgj] iqjkuh nhokjksa dh iksrkbZ dk vFkZ gksxk] [kjy


ds tksM+ksa dh xgjkbZ dks NksM+dj vkuqikfrd eksVkbZA

14.1.3 Plastering on Ceilings


(a) Ceiling shall be measured between the walls or
partitions and the dimensions before plastering shall
be taken, width covered by cornice or cove, if any,
shall be deducted.
(b) Ceiling with projected beams shall be measured over
beams and the plastered side of beam measured and
added.
(c) Soffits of stairs shall be measured as plastering on
ceiling.
(d) Ribs and mouldings on ceilings shall be measured as
for cornices.

14-1-3 Nr ij iyLrj djuk


d Nr dks nhokjksa ;k foHkktdksa ds chp esa ukik tk;sxk rFkk
ifjeki iyLrj ls iwoZ fy;k tk;sxkA pkSM+kbZ esa vkus okyh
dkjfu'k ;k lTtk ;fn gks] dks ?kVk fn;k tk;sxkA
[k ckgj fudys /kjuksa okyh Nr dks /kju ds ij ls ukik tk;sxk
vkSj /kju dk iyLrj okyk Hkkx ekik vkSj tksM+k tk;sxkA

14.1.4 Plastering on Walls


(a) The measurements of wall plastering shall be taken
between the walls or partitions for the length and
from the top of floor or skirting/dado to the ceiling for
the height, dimensions before plastering shall be
taken. Depth of cornices or coves, if any, shall be
deducted.
(b) Sides of pilasters, projections, etc. shall be added to
the plaster on walls.

14-1-4 nhokjks a ij iyLrj djuk


d nhokj ds iyLrj dh eki esa yEckbZ] nhokj ;k foHkktdksa ds chp
dh uki vkSj pkSMk+ bZ] Q'kZ ds ij ls ;k nhokj dh fdukjh ls
Nr rd gksxhA ifjeki iyLrj djus ls igys fy;k tk;sxkA
dkjfu'k ;k ?kqeko dh xgjkbZ ;fn dksbZ gks rks ?kVk nh tk;sxhA

(c) Mouldings, architraves, ceiling ribs, cornices and the


like, on pilasters and around openings etc. shall be
measured as for cornices.
14.1.5

In the case of cornices, etc. the length shall be


measured at the centre of the girth. Flat weather
tops to external cornices, etc. if over 30cm wide
shall be measured as ordinary plaster and not
included in the girth of cornice or moulding. Girth
of cornices etc. shall be measured along the curve
of moulding.

x lhf<;ksa ds ik;s dk iyLrj Nr ds leku ekik tk;sxkA


?k Nr ds eksM+ vkSj ?kqeko dkjfu'k ds leku ekis tk;saxsA

[k fdukjs] c<+s gq, Hkkxksa vkfn ds iyLrj dks nhokj ds iyLrj


esa tksM+k tk;sxkA
x ?kqekoksa f'kYidkjh] Nr dh /kkfj;ks]a dkjfu'ksa rFkk bu tSls dk;Z
iyLrj ij o eks[kksa ds pkjksa vksj vkfn dks dkjfu'k leku
ekik tk;sxkA
14-1-5 dkjfu'k vkfn ds ekeys esa yEckbZ xksykbZ ds dsUnz ls ekih
tk;sxhA ok dkjfu'k vkfn ds likV ok;q f'k[kj ;fn 30
lsea h- ls vf/kd pkSMa+s gks rks lkekU; iyLrj tSls ekis tk;sx
a s
vkSj dkjfu'k ;k ?kqeko dh xksykbZ esa ]'kkfey ugha gksxsa A
dkjfo'k vkfn dh XkksykbZ [kkaps ds o ds lkFk ekih tk;sxhA

285

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
SPECIAL CONDITIONS Contd...
fo'ks"k 'krZs tkjh
14.1.6

Circular work n exc 6 metres mean radius shall


be measured separately from the flat work and
20% addition shall be made to the rates except on
the rates for taking down plastering, raking out
joints, hacking for key, dubbing out, removing
lime wash, etc. and pointing.

14-1-6 pdkj dk;Z ftudh vkSlr f=T;k 6 ehVj ls vf/kd u gks


dks likV dk;Z ls izFkd ekik tk;sxk vkSj njksa esa 20% tqMx
+s k
flok; mu njksa ds tks iyLrj m[kkM+us lfU/k;ka [kksyus]
pkHkh dh dVkbZ] xM<ksa dh [kqykbZ] pwuk lQsnh gVkus vkfn
;k Vhi djus ds dk;Z ij ykxw gksrh gSaA

14.2

MeasurementsPointing
The method of measurements and adjustment
shall be same as described for Plastering".

14-2

14.3

Rates

14.3.1

The rates include for work in small quantities.

14-3 njs a
14-3-1 bu njksa esa NksVh ek=k ds dk;Z 'kkfey gSaA
14-3-2 bu iyLrj dk;Z dh njksa esa 'kkfey gSa%
d lrgksa dks laokjukA
[k tksM+ksa vkfn dh pkHkh esa iyLrj dh eksVkbZ
x mBkoksa fdlh Hkh pkSM+kbZ ds dejs] Hkhrjh xksy dksus] 80 feehrd pkSM+s ;k xksy [kqykbZ lfgr] ckgjh xksy dksus 80 feeh rd
pkSMs+ ;k xksy flok; xkjs ds iyLrj vkSj fyikbZ ds tgka dksus
vkfn fdlh xksykbZ ds 'kkfey gksrs gSaA
?k tyjks/kh inkFkksZ dk mRiknd dh fu/kkZfjr f;k vkSj fu/kkZfjr
ek=k esa feJ.k cukus ds fy, vko';d Jfed vkSj lk/kuA bu
njksa esa tyjks/kh feJ.k dh vkiwfk 'kkfey ugha gS ;fn vkiwfk
Bsdsnkj us dh gS rks mls izFkd ekik tk;sxk rFkk **dsoy
vkiwfk** dh njksa esa ns; gksxkA

14.3.2 The rates for plastering include for:


(a) Preparing the surfaces.
(b) Thickness of plaster key in joints, etc.
(c) Arrises, chamfers of any width, internal rounded
angles upto 80mm in width or girth external rounded
angles upto 80mm in width or girth, except in the
case of mud plaster and leeping where angles etc. of
any girth are included.
(d) All labour and equipment necessary for incorporating
integral waterproofing compound in the manner
specified by the manufacturer and in the proportions
indicated. The rates do not include for supply of
integral waterproofing compound, which if supplied
by the Contractor, shall be measured separately and
paid for at Supplied only" rates.
(e) Scoring surface of plastering for key, where the surface
is not required to be finished fair.

eki&Vhi dk;Z
eki vkSj O;oLFkkvksa dh fof/k ogh gS tSlh fd *iyLrj* dk;Z
ds fy, fu:fir gSaA

M pkHkh ds fy, njkjh iyLrj lrg tgk lrg dks pednkj


ugha cukuk gksA
(f) Curing of plastered surface.
p iyLrjh lrg dk mipkj djukA
(g) Cleaning stains and dripping mortar from floors and N NhaVs vkSj fxjs gq, iyLrj dks Q'kZ vkSj nhokjksa vkfn ij ls
walls, etc.
lkQ djukA
Dubbing out shall not be paid for in the case of
new work nor for rough surfaces of old brickwork
or masonry where the face is in plumb as the rates
for plastering include for the necessary" dubbing
to such surfaces.

14-3-3 xM<+kas dh HkjkbZ uohu dk;Z esa ns; ugha gS vkSj u gh iqjkuh bZV
ds dk;Z ;k fpukbZ ij tgka vkoj.k yEc gks D;ksfa d iyLrj
dh njksa esa bl izdkj dh lrgksa dh vko';d HkjkbZ 'kkfey gSA

14.3.4 Plastering in Patches in Repairs:(a) Plastering in patches (in repairs), exc 3 sq.m each
patch, shall be paid for at the appropriate rate for
new work in addition to the payment for preparing
old walls to receive plastering. Nothing extra shall
be admissible for matching with existing work etc.

14-3-4 ejEerksa esa isou esa iyLrj djukA


d isou esa iyLrj ejEer esa] 3 oeh ls vf/kd dk Hkqxrku u;s
dk;Z dh njksa ds vUrxZr gksxk] **iyLrj djus ds fy, iqjkuh
nhokjksa dks laokjuk** ds varZxr gksus okys Hkqxrku ds vykokA
fo|eku dk;Z ls feyku ds fy, dqN Hkh vfrfjDr nsuk xzk
ugha gksxkA

14.3.3

286

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
SPECIAL CONDITIONS Contd...
fo'ks"k 'krsZ tkjh
(b) Plastering in patches, n exc 3 sq. m each patch, shall
be paid for as in (a) above but with an addition of 10%
over the rates.
(c) Any individual patch (other than nail hole, plug hole,
etc.) n exc one-tenth of a sq. m shall be measured as
one tenth sq. m. Repairs to nail holes, etc., are included
in the re-decoration rates vide Section 15 White
washing, colour washing and Distempering.

14.3.5 The rates for pointing include for:


(a) Preparing the surfaces.
(b) Curing of pointed surface.
(c) Cleaning stains and dripping mortars from floors and
walls, etc.
14.3.6

Pointing in Patches in Repairs:-

(a) Pointing in patches (in repairs), exc 3 sq. m each patch,


shall be paid for at the appropriate rates for new work
in addition to the payment for Raking out joints or
pointing in old walls. Nothing extra shall be
admissible for matching with existing work etc.

(b) Pointing in patches, n exc 3 sq. m each patch shall be


paid for as in (a) above but with an addition of 10%
over the rates.
(c) Any individual patch (other than nail hole, plug hole,
etc.) n exc one-tenth of a sq. m shall be measured as
one tenth sq. m. Repairs to nail holes etc. are included
in the re-decoration rates vide Section 15 White
washing, colour washing and Distempering.

[k 3 o-eh- ls vuf/kd izR;sd isou ds iyLrj dk


Hkqxrku d ds vuqlkj gksxk fdUrq njksa esa 10 %
vf/kd tqM+sxkA
x ,d o-eh- ds n'kesa Hkkx ls vuf/kd] dksbZ ,d isou dhy
ds Nsn Bsih Nsn vkfn ds vykok dks ,d oeh ds n'kesa
Hkkx ds :i esa ukik tk;sxkA ejEer esa dhy ds Nsn vkfn
[kaM 15 dh iqu% lTtk dh njksa esa 'kkfey gSAa lQsnhdjuk]
jax iksruk vkSj fMLVsaEij djukA
14-3-5 Vhi dh njksa esa 'kkfey gSa%
d lrg rS;kj djukA
[k Vhi dh gqbZ lrg dk mipkj djukA
x Q'kZ vkSj nhokjksa ij ls NhaVs vkSj fxjkgqvk elkyk lkQ
djukA
14-3-6 ejEer esa isou yxkdj djukA
d isou yxkdj Vhi ejEer esa izR;sd 3 oeh- ls vf/kd
dk Hkqxrku u;s dk;Z ds vrxZr mi;qDr njksa esa fd;k
tk;sxkA ml Hkqxrku ds vfrfjDr tks **tksM+ [kksyuk ;k
iqjkuh nhokjksa esa Vhi djuk** ds fy, gksxkA fo|eku
dk;Z ds lkFk feyku ds fy, dqN Hkh vfrfjDr ugha
fn;k tk;sxkA
[k isou yxkdj Vhi] 3 oxZ ehVj ls vuf/kd gj id isou
[k.M d ij ds rjg ns; gksxk fdUrq njksa esa 10
vf/kd tqM+sxkA
x dksbZ ,d isou dhy ds Nsn Bsih ds Nsn vkfn ds vykok
,d oxZeh- ds n'kes Hkkx ls vuf/kd dks ,d oxZeh ds
n'kes Hkkx ds :i esa ekik tk;sxkA dhy ds Nsn vkfn
Hkkx 15 ds varxZr iqu% lTtk dh njksa esa 'kkfey gSA
lQsnh djuk] jax iksruk vkSj fMLVsaEij djukA

287

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
SUB-SECTION APLASTERING
miHkkx&d iyLrj djuk
CEMENT, CEMENT LIME AND LIME PLASTER WORK
lhesaV] lhesaV pwuk vkSj pwus ls iyLrj dk;Z
Floating/setting coat of plaster shall be paid under items 14004
and 14006, The rates under items 14001 to 14003 include for
finishing the surface fair and even.

PER SQUARE METRE


14001 Rendering 10mm thick
on fair faces of brick
work or concrete sur
faces
14002 Ditto on stone masonry
surfaces or surface other
than fair face of
brick-work or on one

side of lathing
14003 Rendering 10mm thick
on the other side of

lathing

pyk;eku@LFkkfir rg ds iyLrj dk Hkqxrku] en 14004 o 14006


ds varxZr gksxkA en 14001 ls 14003 rd dh njksa esa lrg dks
lery vkSj pedhyk cukuk 'kkfey gSaA

Lime plaster

Cement lime plaster

pwuk iyLrj

lhesaV pwuk iyLrj

1%2

1%3

1%1%6

1%1%8

1%2%9

Cement plaster Add if in


lhesaV iyLrj
ceilings

1%3

1%4

1%6

Rs.

Rs.

Rs.

tksMsa+ ;fn
Nr esa gSa

Rs.

Rs.

Rs.

Rs.

Rs.

76.40

71.00

88.50

79.50

83.80

91.90

85.90

107.70

96.50

57.20

55.20

63.90

59.40

61.60

71.20

65.20 58.30

20.10

18.80

23.20

20.90

22.00

26.80

23.80 20.40

12.50

12.50

12.50

12.50

12.50

12.50

12.50 12.50

3.60

20.60

20.60

20.60

20.60

20.60

20.60

20.60 20.60

3.60

14007 All as in item 14001

but 12mm thick

84.80

78.60

97.70

87.80

92.60

113.80 100.70 85.40

7.30

14008 All as in item 14002

but 12mm thick

100.00

92.80

116.30

104.10

14004 Add or deduct to/from


the rates for rendering
for each 5 mm
thickness over or

under 10mm
14005 Add to items 14001 to
14003 if rendering is to
be finished even and
smooth (without using
extra lime or cement)
14006 Extra over item 14004 if
the additional thickness is provided as
floating/setting coat

14009 Screed bed or bedding


layer of mortar 15 mm
thick for laying floor

finishes
14010 Add or deduct from
item 14009 for each
5mm thickness over or

under 15mm

Rs.

103.10 91.10 77.30

7.30

101.90 126.00 111.00 93.70

7.30

110.00 136.00 119.90 101.20

7.30

izfr oxZ ehVj


14001
14001bZV ;k dahV dh LoPN
lrg ij 10 feeh- eksVs
iyLrj dk izfriknu djuk
14002
14002mi;ZqDr fdUrq iRFkj dh
fpukbZ ;k bZV dh LoPN
lrg ds vykok ;k ydM+h
ds r[rksa ds ,d rjQ
14003
14003ydM+h ds r[rs ds nwljh
rjQ 10 feeh iyLrj dk
izfriknu djuk
14004 10 feeh ls vf/kd ;k de
eksVs iyLrj ds ij izfr
5 feeh ds fy, njksa esa tksMas+
;k ?kVk;s
14005
14005en 14001 ls 14003 esa tksM+ s
;fn lrg le o fpduh
cukuh gS fcuk vfrfjDr
pwuk ;k lhesV
a iz;ksx fd;s
14006
14006en 14004 ij vfrfjDr
;fn vfrfjDr eks V kbZ
pyk;eku@ LFkkfir rg
ds :i esa yxkbZ xbZ
14007
14007lc en 14001 tSlk fdUrq
12 feeh eksVk
14008
14008lc en 14002 tSlk fdUrq
12 feeh eksVk
14009
14009Q'kZ laiwfrZ ds fy, 15
feeh eksVh elkys dh rh[kh
rg ;k fcNkou yxkuk

110.60 98.10 83.50

24.00

21.60 18.80

14010
14010en 14009 es tksM+sa ;k
?kVk;sa] 15 feeh ls vf/kd
;k de eksVh rg ij

izfr 5 feeh ds fy;s

288

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
CEMENT, CEMENT LIME AND LIME PLASTER WORK Contd...
lhesaV] lhesaV pwuk vkSj pwus ls iyLrj dk;Z tkjh...
PER SQUARE METRE

14011Setting coat 3mm thick,


trowelled to even and

smooth finish
14012Ditto but 5 mm thick

Lime plaster
pwuk iyLrj
1:1
Rs.
39.00
56.00

Cement
plaster
lhesaV iyLrj
1%2
Rs.
44.40
65.10

Add if in
ceiling
tksM+s ;fn Nr
esa gS
Rs.
8.70
14.50

14013 Neeru finish to plastering as specified

14014 Pargetting flues exceeding 0.20sq. m


in sectional areas, with 20mm thick
lime mortar (1 lime:2 sand:l cowdung)

and coring
14015 Provn of sagol finish on plastered

surface of internal wall and ceiling


14016 3mm thick wall care putty on wall
14017 3mm thick wall care putty on ceiling

46.64

74.10

14011 3feeh eksVk vfUre vLrj.k dUuh ls


pkSjl vkSj fpduh laiwfrZ
14012 mi;qZDr] fdUrq 5 feeh eksVh

izfr oxZ ehVj

Rs.

PER SQUARE METRE

izfr oxZ ehVj

14013 funsZ'kkuqlkj iyLrj ds ij lw[ks lhesaV ls ?kqVkbZ


djuk
14014 fpeuh ds 0-20 oxZ ehVj ls vf/kd ds ?ksjs esa 20 feeh
eksVs pwus ds elkys pwuk&1% ckyw&2% xkscj &1 ls
iyLrj djuk vkSj fdukjs cukuk

9.80
24.40
26.90

SPECIAL FINISHES
fo'ks"k laifrZ;ka
The rates for special finishes do not include for rendering coat.
PER SQUARE METRE
14018 Sand-faced plaster as specified

14019 Dry dashing on rendering coat as

specified

14020 Rough cast plaster as specified


14021 Washed stone grit plaster on exterior
walls in two layers, under layer 12mm
cement plaster 1:4 (1 cement: 4 coarse
sand ) furrowing the under layer with
scratching tool, applying cement slurry
on the under layer @ 3 Kg of cement per
square metre, top layer 15mm cement
plaster 1:1/2:2 (1 cement: 1/2 coarse sand
: 2 stone chipping 10mm nominal size)
in panels with groove all around as per
approved pattern including scrubbing
and washing, the top layer with brushes
and water to expose the stone chippings
.complete all as specified (Paymentfor
providing grooves shall be made

separately).

Rs.
80.30

80.90

305.50

fo'ks"klaifkZ dh bu njksa esa rg izfriknu 'kkfey ugha gSA


izfr oxZ ehVj
14018 ckyqbZ iyLrj fufnZ"Vkuqlkj
14019 izfrikfnr ijr ij fufnZ"Vkuqlkj lw[ks lhesaV
dh ?kqVkbZ djuk
14020 fufnZ"Vkuqlkj eksVs iyLrj dh ijr yxkuk

289

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
SPECIAL FINISHES Contd...
fo'ks " k la i frZ ; ka & tkjh--PER SQUARE METRE
14022 Extra for washed stone grit plaster on
circular work not exceeding 6m in radius

(in two coats).


14023 Extra for using white cement in place of
ordinary cement in the top layer of the

item of washed stone grit plaster.

izfr oxZ ehVj

Rs.

20.80

46.10

PER RUNNING METRE


14024 Forming groove of uniform size 15mm
wide and 15mm deep in the top layer of
washed stone grit plaster as per
approved pattern using wooden battens,
nailed to the under layer including
removal of wooden battens, repair to the
edges of panels and finishing the groove
complete as per specifications and
direction of the Engineer-in-charge :

15.80
MISCELLANEOUS

fefJr
PER RUNNING METRE
14025 Extra over rendering or plastering for
work in isolated widths or in widths
not forming part of general plastering
such as in bands, sunk panels,
cornices, skirtings, drip moulds and
similar work exc 15 cm but n exc 30
cm in width or girth; including cutting
to edges, all mi- tres and stopped ends,

etc.
14026 Ditto but n exc 15 cm in width or girth

14027 Extra over rendering/plastering for


rak- ing as in strings to stairs, railing
and similar work (each edge

measured)

iz f r ehVj

Rs.

14025

vfrfjDr] izfriknu ;k iyLrj ds dk;Z tks vdsyh


pkSMk+ bZ okys ;k ,slh pkSMk+ bZ okys tks dke vke
iyLrj ds dk;Z dk Hkkx ugha gS]as tSls eksM] Vadh ds
fdukjs dkjfu'ksa fdukfj;k] jlko ds <kaps rFkk leku
dk;Z 15 lseh- ls vf/kd vkSj 30 lseh- ls vuf/kd]
rFkk fdukjs] lHkh Nksj vkSj vfUre fdukjs vkfn
cukuk lfgr

22.00

14026
14027
6.30

mi;qDZ r] fdUrq eksVkbZ ;k xksykbZ 15 lseh- ls vf/kd


ugha

17.20

vfrfjDr] izfriknu@iyLrj dk;Z ij cukoV


dk;Z ds fy, tSls fd lh<+h ds iknksa] jsfyx vkSj
leku dk;ksZ esa izR;sd fdukjk ekik tk;sxkk

290

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
MISCELLANEOUS Contd...

fefJr tkjh
PER RUNNING METRE

Rs.

14028 Extra for forming external or internal


rounded angles, exc 80mm but n exc
200mm girth (over 200mm girth to be

measured as circular work)


14029 Forming V grooves in plaster n exc 10mm

deep and n exc 10mm on face


14030 Forming square grooves in plaster n exc

12mm deep and n exc 15mm on face

8.50
1.30
1.80

iz f r ehVj
14028 vfrfjDr] ckgjh vkSj Hkhrjh dks.k 80 fe-eh- ls vf/kd
vkSj 200 fe-eh- ls vuf/kd dks laokjus ds fy,
ifjf/k pkdkj dk;Z leku eisxhA
14029 iyLrj esa 10 fe-eh- ls vuf/kd xgjh vkSj lkeus ls
10 fe-eh- ls vuf/kd dh V vkd`fr;k cukuk
14030 iyLrj esa 12 fe-eh- ls vuf/kd xgjh vkSj lkeus ls 15
fe-eh- ls vuf/kd dh cxkZdkj vkd`fr;k cukuk

FORMING LETTERS, ETC.

'kCn vkfn cukuk


(a) A part of a cm (of height) shall be paid as one cm.

(b) Commas, hyphens, brackets, full stops and similar small


cutting shall each count as a half letter of 2 cm height;
arrows as two letters and index hands as four letters of 2
cm height.

[k

Rs.

EACH
14031Forming letters, figures etc. by cutting 'V
grooves in new lime, cement-lime or cement

plaster (per cm of height)

1.80

,d lseh- ds Hkkx pkbZ esa dk Hkqxrku ,d lseh ekudj


gksxkA
v/kZfojke ;kstd] dks"Bd iw.kZ fojke vkSj leku izR;sd NksVh
dVkbZ dh 2 lseh- pk vk/kk 'kCn] rhj ds nks 'kCn rFkk gkFk
ds fpUg dks pkj 'kCn ds leku ekuk tk;sxkA
iz R ;s d
14031
14031pwuk] lhesVa pwuk ;k lhesVa ds u;s iylrj esa V vkd`fr
esa dVkbZ }kjk 'kCn ;k vkd`fr;ka vkfn cukuk izfr lseh
pkbZ esa

MUD PLASTERING AND LEEPING

feh xkjk iyLrj vkSj fyikbZ

;g njsa ?kqekonkj vkSj xksykdkj dk;Z ij Hkh ykxw gSaA

The rates also apply to curved or circular work.


PER SQUARE METRE

14032 Mud plastering 25mm


thick on rigid surfaces
except rubble masonry

(in one coat)


14033 Mud plastering 25mm thick
on wood laths, reed walling,
wire netting, etc. (one side
only) and on rubble
masonry (in one coat)
14034 Mud plastering 25mm thick
on the other side of wood
laths, reed walling, wire
netting etc. (in one coat)

On walls, partitions On horizontal suretc.


face

nhokjks]a foHkktuksa vkfn


ij

lekukUrj lrg ij

Rs.

Rs.

36.80

30.30

41.50

36.30

36.80

izfr oxZ ehVj


14032
14032:{k lrgksa ds ij iRFkjh fpukbZ ds
vfrfjDr 25 feeh eksVk xkjs dk
iyLrj djuk ,d rg
14033
14033ydM+h ds r[rks]a ckl dh nhokjks]a rkj
dh tkyh vkfn ij dsoy ,d rjQ
vkSj iRFkjh fpukbZ ij ,d rg 25
feeh eksVk xkjs dk iyLrj djuk
14034
14034ydM+h ds r[rks]a ckal dh nhokjks]a rkj
dh tkyh vkfn ij nwljh vksj 25 lseh eksVk ,d rg xkjs dk iyLrj djuk

291

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
MUD PLASTERING AND LEEPING Contd...
feh xkjk vkSj fyikbZ tkjh
PER SQUARE METRE
14035 Add to or deduct from items
14032, 14033 and 14034 for
each 5 mm thickness over or
under 25 mm thickness
14036 Mud leeping

On walls,
partitions etc.

On horizontal
surface

nhokjksa foHkktuksa
vkfn ij

lkekukUrj lrg ij

Rs.
10.20
7.10

Rs.
9.10
5.50

izfr oxZ ehVj


14035
1403525 lseh- ls vf/kd ;k de eksVkbZ ds fy,]
izR;sd 5 lseh- eksVkbZ ij en 14032]
14033 rFkk 14034 es]a tksM+s ;k ?kVk;sAa
14036
14036xkjs dh fyikbZ

TAKING DOWN PLASTERING ON LATHING


ydM+h ds r[rksa dh nhokj ij ls iyLrj m[kkM+uk
(a)

The rates in this table relate to walls, partitions, ceilings,


etc, and include for all necessary lowering, etc., removal
of rubbish off the premises, removal and depositing
serviceable materials where directed and leaving the work
clear of any plastering.

(b)

The rates for taking down plastering are for any


thickness.

[k

PER SQUARE METRE


14037 Taking down plastering on lathing
(other than wire-netting), without
removing lathing, in lime mortar (one
side only measured in cases where both

sides are plastered)


14038 Ditto, but in cement lime or cement
mortar (ditto)

Rs.

6.00
8.70

bl lwph dh njsa nhokjksa] foHkktuksa] Hkhrjh Nr vkfn ls


lEcfU/kr gS(a rFkk lHkh vko';d vourksa vkfn lfgr gSa dk;Z
LFky ls eyok gVkuk] mi;ksxh lkexzh dks gVkuk vkSj
funsZf'kr LFkku ij tek djkuk] vkSj lrg dks fdlh Hkh
iyLrj ls lkQ djuk 'kkfey gSA
iyLrj mrkjus dh ;g njsa fdlh Hkh eksVkbZ ds fy;s gSaA
izfr oxZ ehVj
14037
14037ydM+h ds r[rksa dh nhokj ij ls pwuk iyLrj
rkj tkyh ds vfrfjDr fcuk r[rs gVk;s] mrkjuk
tgka nhokj ds nksuksa rjQ iyLrj gks ogka dsoy
,d rjQ dk ekik tk;sxkA
14038
14038mi;qZDr] fdUrq lhesaV pwuk ;k lhesaV ds elkys esa
mi;qZDr

PREPARING OLD WALLS (To receive plaster, etc.)


iqjkuh nhokjkas dks laokjuk djuk iyLrj xzg.k djus ds fy,
izfr oxZ ehVj
PER SQUARE METRE
14039 Taking down mud plaster on brick or
stone walls, etc. including raking out
joints, hacking for key, scrubbing down

with water, etc.


14040 Ditto, but lime plaster, any description

14041 Ditto but cement or cement lime plaster,


any description

14042 Removing old lime wash (if any), hacking


for key, raking out joints of old brick work
or stone work built in lime or mud mortar;
not previously plastered; and scrubbing
down with water etc. to receive plaster
14043 Add to item 2114 if walls are built in
cement or cement lime mortar

Rs.

10.30
19.10
28.80

11.90
6.90

14039
14039bZaV ;k iRFkj dh nhokjksa vkfn ij ls xkjs dk
iyLrj mrkjuk( tksM+ fudkyuk pkHkh ds fy,
dVkbZ djuk] ikuh ls jxM+dj lkQ djuk lfgr

14040
14040mi;qDZ r] ysfdu fdlh Hkh izdkj dk pwus dk iyLrj

14041
14041mi;qDZ r] ysfdu fdlh Hkh izdkj dk lhesVa ;k pwuk
lhesaV dk iyLrj
14042
14042bZV ;k iRFkj dh pwus ;k xkjs ls fpuh iqjkuh nhokjsa
ftu ij igys iyLrj ugha gqvk gS ij ls pwus dh
iqrkbZ mrkjuk ;fn gks pkHkh dh dVkbZ djuk]
tksM+ fudkyuk rFkk ikuh vkfn ls jxM+dj /kksdj
iyLrj xzg.k djus ;ksX; cukuk
14043
14043en 2114 esa tksMas+ ;fn nhokjsa lhesVa ;k lhesVa pwus
ds elkys esa cuh gksa

SECTION 14

292

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
DUBBING ON OLD WALLS
iqjkuh nhokjksa dks laokjuk
Plastering after dubbing out, shall be paid under item 14004
& 14006.
PER SQUARE METRE
14044 Dubbing out average
10mm thick on irregular
face of walls (when
specifically ordered in

writing)
14045 Add or deduct for each 5
mm thickness over or
under 10mm thickness

(ditto)

Lime
plaster

laokjus ds ckn iyLrj dk;Z dk Hkqxrku en 14004 vkSj 14006 ds


vUrxZr gksxkA

Cement lime
plaster

Cement plaster

pwuk IyLrj lhesaV pwuk


iyLrj

lhesaV iyLrj

1:3
Rs.
60.20

1:1:8
Rs.
68.60

1:4
Rs.
80.30

1:6
Rs.
66.40

18.80

20.90

23.80

20.40

izfr oxZ ehVj


14044
14044nhokj dh vfu;fer lrg ij
10feeh eksVh fpdukbZ fcNkuk tc
fo'ks"k :i ls fyf[kr :i esa vkns'k
gks
14045
1404510 feeh ls vf/kd ;k de eksVkbZ
ij izR;sd 5 fe-eh- ds fy, tksMas ;k
?kVk;sa tc fo'ks"k :i ls fyf[kr esa
vkns'k gks

METAL LATHING
/kkrq dh iRRkh yxkuk
izfr oxZ ehVj

PER SQUARE METRE


14046 GI wire netting 0.90mm dia and
12mm mesh lathing to wood or metal
studding, joists, etc. in walls, ceilings,
stanchions, beams, etc. including all

laps, cutting and waste


14047 Add to last, if in repairs in patches n
exc 5 sq. m each, including taking
down old and jointing new to old
as required (patches exc 5 sq.m each
to be measured as new work)

Rs.

307.60

15.60

14046
14046nhokjks]a Nrks]a [kEHkks]a lgrhjksa vkfn ij <ys gq,
rkj dh 0-9 feeh- O;kl vkSj 12 feeh dh
tkyhnkj ifk;k ydM+h ;k /kkrq dh [kwaVh
/kj.k vkfn ij yxkuk] eqM+kbZ] dVkbZ fu'ks"k
lfgr
14047
14047vfUre esa tksfM+;s] ;fn ejEer esa isou 5
oxZeh- ls vf/kd ugha gS] iqjkus dks fudkyus
rFkk u;s dks iqjkus ls vko';drkuqlkj tksMu+ k
5 oxZeh ls vf/kd ds isou u;s dk;Z :i esa
ukis tk;saxs

SUB SECTION B- POINTING


mi[kaM [k Vhi djuk
POINTING GENERALLY
vkerkSj dh Vhi djuk
(a)

(b)

;g njsa iqjkus dk;Z esa lfU/k;ka fudkyuk rFkk nksuksa izdkj dh


lh/kh lekukUrj] [kM+h ;k <yqvk vkSj xksy lrgksa ij tksMk+ as
dh fdlh Hkh pkSM+kbZ ds fy;s gSaA
Arches, mouldings, cornices, necking, chajjas, etc., shall [k esgjkos] lkafp;k] dkjfu'ksa] d.<ys] NTts vkfn nhokj
be measured alongwith walling, if they are pointed in
xhfj ds lkFk ukis tk;saxs ;fn ;s mlh rjg ls Vhi fd;s
the same manner.
x;s gSaA

The rates for raking out joints in old work and pointing
apply to both plain (horizontal, vertical or inclined) and
circular surfaces, in any width of joint.

293

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
RAKING OUT JOINTS (IN OLD WORK)
lfU/k;ka [kksyuk iqjkus dk;Z esa
The rates include for raking or cutting out joints and decayed
mortar etc, not less than 12mm deep, washing the joints,
removing rubbish off the premises, and keeping the surface to
be pointed wet for 2 days prior to re-pointing.

bu njksa esa lfU/k;k vkSj xys elkys vkfn dks mrkjuk ;k dkVuk]
lfU/k;ka dks /kksuk] dk;ZLFky ls eyok gVkuk vkSj lrg ftl ij Vhi
gksuh gS mls nks fnu rd xhyk j[kuk 'kkfey gSaA

Work built in

PER 10 SQUARE METERS

14048 Raking out joints/ pointing to


brick work in walls or to
bricks on edge in floors,

surface channels, roofs, etc.


14049 Ditto to brick work or brick
tiles, laid flat, in floors, surface

channels, roofs, etc.


14050 Ditto, to brick tiles 30cm by
15cm laid flat as in floors,
roofs, ceilings, chajjas, etc.
14051 Ditto, to brick-tile work in
facing, with brick tiles laid flat

in stretcher courses
14052 Ditto, to block in course masonry,
or concrete block walling
14053 Ditto, to squared rubble
masonry, coursed or uncoursed
14054 Ditto, to random rubble or
polygonal rubble uncoursed
or brought up to courses
14055 Ditto, to stone slab or precast
concrete slab floor, any

description, laid flat


14056 Ditto, to stone sett paving, any

description

Mud
mortar

dk;Z var% fufeZr


Lime
Cement or
mortar
cement lime
mortar

xkjk elkyk pwuk elkyk lhesVa ;k lhesVa


pwuk elkyk
Rs.

Rs.

Rs.

83.00

136.60

176.30

55.10

90.90

110.80

43.20

70.00

83.90

112.70

165.90

215.90

48.20

67.20

81.10

51.80

85.30

101.40

57.70

93.90

111.30

27.80

45.10

55.00

56.30

90.90

110.80

PER 10 RUNNING METRES


14057 Raking out joints/ pointing
to masonry or brick-work in
single detached joints for

flashing, etc.

izfr 10 oxZ ehVj

14048
14048bZaV dh nhokj ;k [kM+h bZaV ds Q'kZ]
lrgh ukfy;ksa Nrksa vkfn ds tksM+
[kksyuk vkSj Vhi djuk
14049
14049mi;qZDr] Q'kksZ lrgh ukfy;ksa] Nrksa
vkfn esa likV fcNh bZV ;k Vkby
ij
14050
14050mi;qZDr] 30 lseh- x 15 lseh- dh bZV
Vkbys]a Q'kks]Z Nkks]a Hkhrjh Nkks]a NTtksa
vkfn esa likV fcNh ij
14051
14051mi;qZDr] lkeus dh vksj bZV Vkby
dk;Z] MksyhdkVksa esa bZV Vkbyksa ds

likV fcNkou lfgr


14052
14052mi;qZDr] eksVh fpukbZ ds Hkkxksa ;k
dahV dh nhokj ds Hkkxksa esa
14053
14053mi;qZDr] pkSjl iRFkj] x<+s ;k vux<+
dh fpukbZ ij
14054
14054mi;qDZ r] vleku] iRFkj ;k cgqdkS.kh;]
x<+s gq;q s ;k vux<+ iRFkj dh dkV rd
ykbZ xbZ fpukbZ ij
14055
14055mi;qZDr] iRFkj dh if;ksa ;k iwoZ
fojfpr dahV dh fdlh Hkh izdkj dh
if;ksa Q'kZ esa likV fcNh gqbZ ij
14056
14056mi;qZr] iRFkj dh fdlh Hkh izdkj dh
fcNh iVjh canh

izfr 10 ehVj

10.10

15.90

19.70

14057
14057tksM+ fudkyuk@fpukbZ ;k baZV ds
dk;Z esa ,dy vlaxr tksM+ksa dks
tyjks/ku vkfn ds fy, Vhi djuk

SECTION 14

294

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z

(a)
(b)

POINTING
Vhi dk;Z
The rales apply to pointing on new or old work.
d ;g njsa u;s vkSj iqjkus dk;Z esa Vhi dk;Z ij ykxw gksrh gSaA
For old work the rates do not incude for raking out [k iqjkus dk;Z esa fo|eku lfU/k;ksa dks fudkyuk 'kkfey ugha gSA

existing joints.
(Note: Raking out joints in new work is included in the
rates for new work)
(c)
Where joints are indicated to be struck flush in the same
mortar as work proceeds, no payments shall he made
under pointing.
PER 10 SQUARE METER M & L
Lime mortar
BRICK WORK IN WALLS pwuk elkyk

uksks V % u;s dk;Z esa lfU/k;ka fudkyuk u;s dk;Z dh njksa esa
'kkfey gS A
x tgka lfU/k;ka dk;Z ds e/; mlh elkys ls Hkjh tkuh gS ogka
Vhi ds vUrxZr Hkqxrku ugha gksxkA
lkexzh ,ao Je

izfr 10 oxZ ehVj

Cement mortar

1:3
Rs.
459.20

1:3
Rs.
507.20

1:4
Rs.
489.30

690.70

762.80

735.90

14060 Keyed pointing to brick 432.80

walls
14061 Ditto, to brick-tile fecing,
with tiles laid flat in
649.20

stretcher course
14062 Flush pointing to brick
358.80
walls

424.80

472.80

454.90

637.20

709.30

682.60

350.80

398.80

380.90

14058
14058bZaV dh nhokj esa i[knkj ;k
<yoka Vhi djuk
14059 mi;qDZ r] bZV dh Vkbyksa ds vxzHkkx
ij] Qsyh dkV ij likV yxh
Vkbyksa lfgr
14060 bZVa dh nhokj ij f>jhnkj xksy Vhi
14061
14061mi;qZDr fcNh dkV esa likV
yxh Vkby lfgr bZVa Vkby ds
vxzHkkx ij
14062
14062bZV dh nhokj ij Hkjoka Vhi
bZV dk;Z vkfn Q'kZ] Nrksa
vkoj.kksa vkfn esa

BRICKWORK, ETC. IN
FLOORS,
ROOFS,
APRONS, ETC.
14063 Flush pointing to brick on

edge pavings

272.70
14064 Ditto, to bricks laid flat or
brick tiles in pavings
14065 Flush pointing to 30cm by 181.50
15cm brick tiles, laid flat

in pavings
108.60
MASONRY
14066 Struck pointing to block in
course or ashlar masonry
or concrete block walling
14067 Ditto, to squared rubble,
coursed or uncoursed
14068 Deduct from items 14066 &
14067 for keyed pointing
14069 Add to item 14067 for

raised pointing

nhokjksa esa bZaV dk;Z

lhesaV elkyk

1:2
14058 Struck
or
recessed
Rs.
pointing, to brick walls
467.20
14059 Ditto, to brick-tile facing,
with tiles laid flat in
702.80
stretcher course

266.50

303.40

289.60

177.40

201.50

192.50

109.00

120.60

115.30

311.20

303.10

351.20

333.30

432.80

424.80

472.90

454.90

18.50

18.50

18.50

18.50

154.10

178.20

169.20

158.20
14070 Keyed pointing to random or
polygonal rubble, uncoursed
or brought upto course 450.70

442.70

490.70

472.80

14063
14063[kM+atksa esa [kM+h yxh bZaV ij
Hkjok nhi
14064[kM+atksa esa likV yxh bZaVksa ;k
14064
bZaV Vkbyksa ij
14065
14065[kMa+tksa esa yxh 30 lseh x 15
lseh- dh likV fcNh bZVa Vkbyksa
ij Hkjoka Vhi

fpukbZ
14066
14066eksVh ;k jaxhu fpukbZ ;k dahV
ds [kkapksa dh nhokj ij Hkjoka
Vhi
14067
14067mi;qDZ r] x<+s ;k vux<+] iRFkj
ds pkSdksj VqdM+kas dh fpukbZ ij
14068
14068?kVk;s en 14066 o 14067 esa ls
>hjhnkj xksy Vhi ds fy,
14069
14069tksM+ a s en 14067 esa mHkjh Vhi ds fy,

14070
14070vleku] ;k cgqe[q kh] x<+s gq, ;k
dkV rd yk;s x;s iRFkj ds
VqdM+ksa ij f>jhnkj xksy Vhi

295

SECTION 14

SECTION 14PLASTERING AND POINTING


[k.M 14&iyLrj vkSj Vhi dk;Z
POINTING Contd...
Vhi dk;Z tkjh...

Masonry Contd...
PER 10 SQUARE METRES
14071 Raised pointing to random
or polygonal rubble, uncoursed or brought upto

courses
14072 Flush pointing to block in
course or ashlar masonry or
concrete block walling
14073 Ditto, to squared rubble
masonry, coursed or

uncoursed
14074 Ditto, to random rubble
masonry, uncoursed or
brought upto courses
14075 Ditto, to self faced/ rough
dressed stone slab or precast
concrete slab floors, any

description, laid flat


14076 Ditto, to stone sett paving

any description

fpukbZ tkjh

lkexzh ,ao Je

M&L
Lime mortar

izfr 10 oxZ ehVj

Cement mortar

pwuk elkyk

lhesaV elkyk

1:2
Rs.
809.90

1:3
Rs.
797.90

1:3
Rs.
870.00

1:4
Rs.
843.00

225.50

217.90

265.90

248.00

310.60

302.50

350.60

332.70

348.90

340.90

388.90

371.00

91.70

89.50

102.30

97.60

248.40

242.00

280.50

266.10

izfr 10 ehVj

PER 10 RUNNING METRES

bZaV dk;Z ;k fpukbZ fpfUgr dk;Z]


fpkkdf'kZ r vkfn

(Single Joints in Brickwork or


Masonry in detached work,
flashings, etc.)
14077 Flush pointing

14078 Struck, keyed, raised or

recessed pointing

14071
14071vleku] ;k cgqeq[kh vux<+
;k dkV rd yk;s x;s iRFkj
ds VqdM+ksa ij mHkjh Vhi
djuk
14072
14072eksVh ;k jaxhu fpukbz ;k
dahV ds <akpksa dh nhokj esa
Hkjoka Nhi djuk
14073
14073mi;qZDr] oxkZdkj] x<+s ;k
vux<+ iRFkj ds VqdM+kas dh
fpukbZ ij
14074
14074mi;qDZ r] vleku] x<+s ;k vux<+
iRFkj ds VqdMksa dh fpukbZ ij
14075
14075mi;qDZ r] Lo;a vkd`fr izkIr@cs<xa ]s
iRFkj dh ifV;k ;k iwoZ fojfpr
dahV dh ifV;k ds fdlh izdkj
ds] likV fcNs Q'kZ ij
14076
14076mi;qZDr] fdlh Hkh izdkj dh
iRFkj dh LFkkfir [kaMts ij

61.30

59.10

71.90

67.20

117.80

115.70

128.50

123.70

14077
14077Hkjoka HkjkbZ
14078
14078i[knkj f>jhnkj xksy mHkjh
gqbZ ;k pkSdksj f>jh Vhi

MATERIALS (Supplied only)


lkexzh dsoy vkiwfrZ
PER CUBIC METRE
14079 Sand for plastering or

pointing

14080 Cow dung

Rs.
705.00
705.00

14079
14079iyLrj ;k Vhi dk;Z ds fy,
ckyw
14080
14080xk; dk xkscj
iz f r fda o Vy

PER QUINTAL
14081Chopped straw (Bhoosa)

izfr ?ku ehVj

352.50

14081
14081dVs fruds Hkwlk

296

SECTION 15

SECTION 15WHITE WASHING, COLOUR WASHING AND DISTEMPERING


[k.M 15&lQsnh] jax vkSj fMLVSEij ls iqrkbZ dk;Z
SPECIAL CONDITION
fo'ks"k 'krsZ
15.1 Measurements:
15-1 eki%
15.1.1 Deductions for openings, ends of joists, beams, etc., 15-1-1 eks[kksa] tksM+ksa ds fdukjksa /kjfu;ksa vkfn ds fy, dVkSrh vkSj
and additions for reveals, jambs, sofitts etc., shall
pkS[kVksa] i[[kksa vkSj egjkc vkfn ds fupys Hkkxksa ds fy,
be made as under:
ifjo/kZu fuEu izdkj ls fd;k tk;sxk%
(a)
No deduction shall be made for ends of joists, beams, d eks[kks]a tksMk+ sa ds fdukjks]a /kfjfu;ka] [kEHksa vkfn rFkk 0-5 oxZeh
posts, etc. and openings, n exc 0.5 sq. m each; and
ls vuf/kd fjfDr;ksa ds fy, dVkSrh ugha dh tk;sxh( vkSj
no additions shall be made for reveals, jambs, soffits,
pkS[kVksa] i[[kksa] fupys Hkkxksa ifV;ksa vkfn ds eks[kksa ds fy,
sills, etc. of these openings, nor for finish around
rFkk ukgh] tksMk+ as ds fdukjksa /kjfu;ks]a ifV;ksa vkfn ds pkjksa vksj
ends of joists, beams, posts, etc.
dh iwfrZ ds fy;s] ifjo/kZu fn;k tk;sxkA
(b)
Deductions for openings exc 0.5 sq. m but n exc 3 [k izR;sd eks[kk tks 0-5 o-eh- ls vf/kd vkSj 3 o-eh- ls vuf/kd
gS] ds fy, dVkSrh fuEu izdkj ls gksxh vkSj bu eks[kksa dh
sqm each, shall be made as follows and no addition
pkS[kVksa] i[[kksa] fupys Hkkxksa ifV;ksa vkfn] ds fy, ifjo/kZu
shall be made for reveals, jambs, soffits, sills, etc.. of
these openings.
ugha fd;k tk;sxk%&
(i)
When both faces of wall are treated with the same i
tc nhokj ds gj rjQ ,d gh lkexzh dk mipkj gks rks
finish, deduction shall be made for one face only.
dVkSrh ,d rjQ ls gh dh tk;sxhA
(ii)
When each face of wall is provided with a different ii tc nhokj ds gj rjQ vyx&vyx lkexzh dk iz;ksx gks rks
finish, deduction shall be made for that side on
dVkSrh dsoy ml rjQ dh iqrkbZ ls dh tk;sxh ftl vksj
which width of reveals is less than that of other
eks[ks dh pkSM+kbZ nwljh rjQ ls de gksxh ysfdu tgka eks[ks
side but no deduction shall be made on the other
dh pkSM+kbZ nksuksa rjQ leku gksxh ogka nhokj ds nksuksa rjQ
side where the width of reveals on both faces of
dh iqrkbZ esa ls Ekks[ks dk 50% {ks= ?kVk;k tk;sxkA
walls are equal, deduction of 50% of area of opening
on each face shall be made from the area of finish.
When only one face of wall is treated and the other
face is not treated, full deduction shall be made, if the
width of the reveal on the treated side, is less than that
on the untreated side but if the width of the reveals is
equal or more than that of untreated side, then neither
deductions for the openings nor any additions be
made for reveals, jambs, soffits, sills, etc.
(iv) When width of door frame is equal to thickness of
wall, or is projecting beyond the thickness of wall,
full deduction for opening shall be made from each
face of wall.
(c)
In case of openings of area above 3 sq.m each,
deductions for the opening shall be made from each
face of the wall but jambs, soffits, and sills shall be
measured.
15.1.2 No addition or deduction shall be made for
attachments to surfaces such as casings, conduit
pipes, timbers, electric wiring etc.
15.1.3 Cornices and other wall features, shall be girthed
and included in the general areas.
15.1.4 Corrugated surfaces shall be measured flat as fixed
and not girthed. The quantities so measured shall
be increased by the following percentages and the
resultant included with the general area:
(a) Corrugated steel sheets
14 percent
(iii)

iii tc nhokj ds dsoy ,d rjQ mipkj gks vkSn nwljh rjQ


u gks rks mipkj okyh rjQ ls iwjh dVkSrh gksxh ;fn ml vksj
eks[ks dh pkSM+kbZ ls de gS( ysfdu ;fn nksuksa rjQ pkSM+kbZ
leku gks ;k mipkj u dh xbZ rjQ vf/kd gks rks uk gh dksbZ
dVkSrh gksxh vkSj uk gh eks[kksa dh pkS[kVksa i[[kksa esgjko vkfn
ds fupys Hkkxksa ifV;k vkfn ds fy, ifjo/kZu fd;k tk;sxkA
iv tc njokts dh pkS[kV dh eksVkbZ nhokj dh eksVkbZ ds cjkcj
gks ;k nhokj dh eksVkbZ ls ckgj fudy jgh gks rks nhokj ds
nksuksa rjQ dh iqrkbZ esa ls iwjh dVkSrh gksxhA
x

,sls eks[ks tks 3 o-eh- ls gSa rks nhokj ds gj rjQ esa ls dVkSrh
gksxh ysfdu i[[ks esgjkc vkfn ds fupys Hkkx vkSj ifV;ka
ukih tk;sx
a hA

15-1-2 lrg esa yxh gqbZ oLrq;as tSls Bddu ikuh dh ufydk;sa ikbi
ydM+h ds dk;Z fctyh ds rkj vkfn ds fy, u ifjo/kZu gksxk
vkSj uk gh dVkSrhA
15-1-3 dkjfu'ksZ rFkk vU; nhokj vkd`fr;ka bdh lkekU; {ks= esa
'kkfey djyh tk;saxhA
15-1-4 iukjhnkj lrgksa dks fLFkj leku likV ukik tk;sxk vkSj bDk
ugha( bl izdkj ukis x;s ifjek.k dks fuEufyf[kr izfr'kr ls
o`f) djds izfrQy dks lkekU; {ks= esa ekuk tk;sxk%
d

iukjhnkj yksgs dh pknjsa

14 izfr'kr

297

SECTION 15

(b)

SECTION 15WHITE WASHING, COLOUR WASHING AND DISTEMPERING


[k.M 15&lQsnh] jax vkSj fMLVSEij ls iqrkbZ dk;Z
SPECIAL CONDITION
fo'ks"k 'krsZ
Corrugated asbestos cement
[k iukjhnkj vng lhesaV pknjsa
20 izfr'kr

sheets
20 percent
Semi-corrugated asbestos
cement sheets
10 percent
(d) Nainital pattern roof, plain
sheeting with rolls
10 percent
(e)
Ditto but with corrugated
sheets
25 percent
15.2 Rates
15.2.1 The rates include for:
(1)
Use of all scaffolding, trestles, ladders, cradles, etc.
necessary for execution of work and protective
measures.
(2)
Removing of nails, making good holes, cracks, etc.
(3)
Work in patches, and in narrow \widths. bands,
cornices, pilasters, etc. and cutting in edges to line,
where necessary.
(4)
Spreading and removing coverings to doors,
windows, floors, fittings, etc., to protect them from
splashes.
(5)
Removing and replacing furniture, movable
cupboard, chicks, blinds, etc.
(c)

(6)

Washing floors, cleaning glass, joinery, electric


fittings, wiring, etc. of drops and splashes and
leaving premise, clean and tidy.

15.2.2 First coat of colour wash on newly white washed


surfaces shall be treated as subsequent coat.
15.2.3 First coat of white wash on plastered surfaces,
wherein the previous decoration has been
completely removed, shall be treated as on undecorated surfaces.

x
?k
M-

v/kZ iukjhnkj vng lhesaV pknjsa


uSuhrky uewus dh Nr]
osfYyr lknk pknj
mi;qZDr ysfdu iukjhnkj pknj lfgr

10 izfr'kr
10 izfr'kr
25 izfr'kr

15-2 njs a
15-2-1 bu njksa esa ;g 'kkfey gSa%
1 epku cka/kuk] xMkjh est] lhf<+;ka] >wys] vkfn dk;Z ds
fuiVku esa vko';d] bu lcdk iz;ksx vkSj lqj{kk izcU/kA
2
3
4

dhys fudkyuk] rFkk Nsnksa] njkjksa dks Hkjuk


isou] vkSj ladh.k pkSMk+ bZ] ?kqekoks]a dkjfu'ks]a iyLrj vkfn dk
dk;Z vkSj tgka vko';d gks fdukjksa dks ykbu esa dkVukA
njokts] f[kM+fd;ks]a Q'kks]Z fQfVax vkfn dks NhVks ls cpkus ds
fy, mu ij <Iiu Mkyuk vkSj gVkuk

QuhZpj] pyk;eku vyekfj;ka] fpdsa] insZ vkfn gVkuk rFkk


iqu% LFkkfir djukA
6 Q'kZ dks /kksuk] 'kh'ks tqMk+ phts]a fctyh dh fQfVax rkj xhjh
vkfn ij ls NhaVs vkSj xanxh lkQ djuk rkfd dk;Z LFky
lkQ vkSj LoPN gks tk;aA
15-2-2 ubZ lQsnh dh gqbZ lrg ij jax dh igyh ijr dks nwljh ijr
ekuk tk;sxkA
15-2-3 iyLrj dh gqbZ lrg ij lQsnh dh igyh ijr dks] tgka ij
fd iwoZ lTTkk dks iwjh rjg ls gVk fn;k x;k gS] mls lTtk
ghu lrg ekuk tk;sxkA

PREPARATORY WORK
izkjfEHkd dk;Z
Preparation of old surface shall include brooming down or steel iqjkuh lrg ds rS;kjh dk;Z esa] >kMw ls lQkbZ ;k yksgs ds rkjksa ckys
wire brushing; scrapping down smoke soot, moulds, moss and czq'k ls jxM+kbZ }kjk /kw;sa dh dkfy[k [kqjpuk] dkbZ rFkk vEy ijrsa
efflorescent salts and trading oil and greasy spots.
vksj rsy dh fpdukgV vkSj xzhl ds /kCcs lkQ djuk 'kkfey gSA
PER SQUARE METRE

Preparing surfaces plastered


or unplastered

Washing, rubbing
down and stopping of
distempered and
painted surfaces

Complete removal
of existing
treatment

izfr oxZ ehVj

iyLrj fcuk
iyLrj dh lrgksa /kks u k] jxM+ u k] Nq M + k uk fo?keku mipkj dks
fMLVSEij o jaxhu lrgksa dks iwjh rjg gVkuk
dh rS;kjh
New sur- Old surfaces
faces

ubZ lrgsa iqjkuh


lrgsa

15001 On Walls
15002 On ceiling

Rs.
0.60
0.90

Rs.
1.00
1.40

Rs.
1.60
2.00

Rs.
2.70
3.50

15001
15001nhokjksa ij
15002
15002Hkhrjh Nr ij

298

SECTION 15

SECTION 15WHITE WASHING, COLOUR WASHING AND DISTEMPERING


[k.M 15&lQsnh] jax vkSj fMLVSEij ls iqrkbZ dk;Z
PRIMING SURFACES
vLrj.k lrgs a
PER SQUARE METRE

On walls

15003 Clearcolle on plastered


and other surfaces,
preparatory
to

distempering
15004 Chalk whiting, on
plastered surfaces,
prepara-tory
to

distempering
15005 Priming plastered and
other surfaces with alkaliresistant priming paint

izfr oxZ ehVj

On ceiling

nhokjksa ij

Hkhrjh Nr ij

M&L

Except
primer

M&L

Except

lk o J

fcuk vLrj

lk o J

fcuk vLrj

Rs.

Rs.

Rs.

Rs.

1.90

1.10

2.00

1.30

5.50

3.50

6.40

4.40

17.20

6.90

18.70

8.50

primer

15003
15003fMLVSEij iksrus dh rS;kjh ds
:i esa] iyLrj ;k vU; lrgksa
ij 'kks/ku djuk
15004
15004fMLVSEij iksrus dh rS;kjh ds
:i esa] iyLrj dh lrg ij
[kfM;k lQsnh iksruk
15005
15005iyLrj dh vkSj vU; lrgksa
ij] {kkj fujks/kd vLrj.k jax
ls vLrj yxkuk

WHITE WASHING & COLOUR WASHING


lQsnh rFkk jax iksrkbZ
izfr oxZ ehVj

PER SQUARE
METRE
White washing

Colour washing

lQsnh iksruk

igyh ijr

1st coat

Unde
corated
surface

jax iksruk

Subsequent
coat

igyh ijr

1st coat

Unde
corated
surface

Old de
corateed
surface

lTTkkghu lfTTkr
rnuUrj
lrg
iqjkuh lrg ijr

lTTkkghu
lrg

lfTTkr
rnuUrj
iqjkuh lrg ijr

Rs.

Rs.

Rs.

Rs.

Rs.

Rs

3.90

3.50

3.30

4.10

4.20

3.90

15007 On ceilings

4.40

3.90

3.70

4.60

4.50

4.40

15006 On walls

Old de
corateed
surface

Subsequent
coat

15006
15006nhokjksa ij
15007
15007var% Nr ij

299

SECTION 15

SECTION 15WHITE WASHING, COLOUR WASHING AND DISTEMPERING


[k.M 15&lQsnh] jax vkSj fMLVSEij ls iqrkbZ dk;Z
DISTEMPERING, CEMENT PAINTING, ETC.
fMLVSEij] lhesaV jaxkbZ vkfn
PER SQUARE METRE
15008 Distempering walls with
distemper dry, white or

tinted
15009 Ditto with distemper oil
emulsion, ditto
15010 Ditto with cement paint,

ditto
15011 Add to items 15008 to

15010 for work in ceiliing

1st coat

Subsequent coat

igyh ijr

rnuUj ijr

Rs.

Rs.

9.50

7.20

17.10

10.90

18.90

12.20

2.30

1.30

15012 Add to items 15008 to


15010 in finish to dry
dash or rough cast
.

izfr oxZ ehVj


15008 nhokjksa ij lw[ks] lQsn ;k jaxhu
fMLVSEij ls fMLVSEij djuk
15009 mi;qZDr] vEy ik;l lfgr
mi;qZDr
15010 mi;qZDr] lhesaV jksxu ds
lkFk] mi;qZDr
15011 tksfM+;s Hkhrjh Nr ds dk;Z ds
fy, en 15008 ls 15010 esa
15012 tksMas+ fNrjs gq, ;k [kqjnjs
iyLrj dks fpduk djus ds
fy, en 15008 ls 15010 esa

20%

MISCELLANEOUS
fefJr
The rates for items 2204 to 2206 are for all locations

PER SQUARE METRE


15013 Chalk Whiting on cloth or

hessian
15014 Cement wash with Portland
cement slurry to a smooth
bodied opaque finish

en 2204 ls 2206 dh njsa lHkh LFkkuksa ds fy, gSaA

1st coat

Subsequent coat

igyh ijr

rnuUj ijr

Rs.

Rs.

4.90

4.20

4.70

3.30

izfr oxZ ehVj


15013
15013diM+s ;k twV ij [kfM;k lQsnh
djuk
15014
15014ijry lhes a V ?kks y ls pedhyh
ikjn'kZ d iw f rZ ds fy, iq r kbZ
djuk

MATERIALS (Supplied only)


lkexzh dsoy iwfrZ
PER KILOGRAM
15015 Mineral colour, any
description, dry, fine ground

for colour washing


15016 Distemper, dry, any tint any

shade

15017 Distemper, oil-emulsion, ditto

15018 Cement paint, ditto

15019 Chalk whiting

Rs.

52.90
56.40
70.50
49.40
12.90

izfr fdyksxzke
15015 jaax iqrkbZ ds fy,] [kfut jax] fdlh Hkh
fooj.k ds lw[ks] LoPN vk/kkj okys
15016 fMLVSEij] lw[ks] fdlh Hkh jax] fdlh Hkh
vkHkk ds
15017 fMLVSEij] vEy ik;l] mi;qZDr
15018 lhesaV jksxu] mi;qZDr
15019 [kfM;k lQsnh

300

SECTION 16

SECTION 16GLAZING
[k.M 16&'kh'ks yxkuk
SECTION 16
GLAZING
[k.M 16&'kh'ks yxkuk
SPECIAL CONDITIONS
fo'ks"k 'krsZa
16.1 Measurements:
(a) Each pane of glass shall be measured to the
nearest 0.5cm both in width and height.
(b) Irregular shaped or circular panes shall be
measured as the smallest rectangular area from
which the irregular or circular pane can be cut.
Circular cutting shall be allowed in addition
for all edges cut to curve.
(c) If ground (obscured) glass is ordered, an
allowance in thickness shall be made for loss
due to grinding.
16.2 Rates

16-1 eki%
d 'kh'ks dk izR;sd Qyd] pkSM+kbZ rFkk pkbZ fudVLFk
0-5 lseh rd ekik tk;sxkA
[k vle vkd`fr ;k pkdkj Qyd lcls NksVs vk;rkdkj
tSls ekis tk;saxs ftlls og vle ;k pkdkj Qyd
dkVk tk ldrk gSA pkdkj dkVsa lHkh fdukjksa dh o
dkV] ds vfrfjDr ekU; gksxhA
x ;fn Hkwnoq ks/Z k 'kh'kk ekxka x;k gS] rks f?klkbZ es gqbZ {kfr dh
iwfrZ eksVkbZ c<+kdj dh tk;sxhA
16-2 njs a

16-2-1 'kh'ksnkjh dh bu njksa esa 'kkfey gS%


(a) Oiling/painting of rebates and grooves as
d njkjksa rFkk fNnzksa esa fufnZ"Vkuqlkj rsy@jksxu HkjukA

16.2.1 The rates for glazing include:-

specified.
(b) Fixing of glass in rebates and grooves.

[k njkjksa rFkk fNnzksa esa 'kh'kk yxkkukA


x vkKk@vko';drkuqlkj 'kh'ks dh lh/kh o frjNh dVkbZ
rFkk bl izf;k esa gqbZ {kfr rFkk VwVQwV( pkdkj dVkbZ
vyx ls ekih tk;sxhA

(c) Straight and raking cutting of glass to exact


sizes ordered/required and for the wastage
and breakage involved in the process; circular
cutting shall be measured separately.
(d) Leaving the panes clean on completion.

?k laiwfrZ ij Qyd lkQ djds tkukA

16.2.2 All measurements of cutting shall, unless otherwise


stated, include the consequent waste and breakages
involved.

16-2-2 tc rd fd vU;Fkk dgk u x;k gks] layXu {k; rFkk


VwVQwV dVkbZ dh eki esa 'kkfey gksxhA

16.3 Old Glass


Before any old glass is taken out from its surrounds
for refixing or removal to an other position or to
store, the existing breakages or cracks shall be noted.
Any breakages occuring during taking out and
removal shall be made good by the Contractor at
his own expense.

16-3

The rates for glazing vide items 2221 to 2233 are


applicable for glazing with putty in wooden, metal, stone,
concrete, bricks or other similar surrounds.

iqjkus 'kh'ks
blls igys fd iqjkus 'kh'ks vius LFkku ls] nqckjk yxkus ;k
nwljh fLFkfr nsus ;k tek djkus ds fy, fudkys tk;sa rks
fo|eku VwVu ;k pVdu uksV dh tk;sA 'kh'ks fudkyus ;k
gVkus ds e/; gqbZ VwVQwV dh HkjikbZ Bsdns kj vius [kpsZ ij
djsxkA
en 2221 ls 2233 rd dh 'kh'kk dk;Z dh njs]a ih ydM+h]
/kkrq] iRFkj] dahV] bZV ;k leku izfros'k ij ykxw gSaA

301

SECTION 16

SECTION 16GLAZING
[k.M 16&'kh'ks yxkuk
SHEET GLASS
pknjh 'kh'kk
PER SQUARE
METRE

Thickness in mm

Except
sheet glass
any thickness

eksVkbZ feeh esa

izfr oxZ ehVj

16003 Sheet glass,


selected quality
and glazing
with oil putty in
squares n exc
0.5 sq. m in each

pane

16001
16001lk/kkj.k eku ds
0-5 oeh vuf/kd
'kh'ks ds pkSdksj
Qyd dks rsy
fefJr ih lfgr
yxkuk
16002
16002mi;qZDr] ysfdu
iz R ;s d Qyd
0-5 oeh ls vf/kd
16003
16003pqfuank dksfV ds
'kh'ks ds 0-5 oeh
ls vuf/kd] 'kh'ks
ds pkSdksj Qyd
rs y ih es a
yxkkuk

16004 Ditto, but exc 0.5


sq.m in each

pane

16004
16004mi;qZDr] fdUrq
iz R ;s d Qyd
0-5 oeh ls vf/kd

16001 Sheet glass,


ordinary quality
and glazing
with oil putty in
square n exc 0.5
sq. m in each

pane
16002 Ditto, but exc 0.5
sq. m in each

pane

fdlh Hkh eksVkbZ


ds 'kh'ks ds fcuk
2-0

2-5

3-0

4-0

4-8

5-5

6-3

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

376.50 411.70 458.70 517.50 588.00 682.00 746.60

71.00

504.40 531.40 577.30 633.00 710.00 798.10 862.80

181.30

16005 Extra over sheet glass, ordinary quality,


if sheet glass is ground or obscured or

frosted, on one side

16005 vfrfjDr lk/kkj.k dksfV ds 'kh'ks ds Qyd ij


vfrfjDr] ;fn Qyd [kjkn }kjk ,d vksj ls f?klk
;k jxM+k x;k gks

Rs.
12.30

FIGURED GLASS
fpf=r 'kh'ks
PER SQUARE METRE

Thickness in mm

Except glass
(any thickness)

eksVkbZ feeh esa


16006 Figured glass, pin head
type and glazing with
oil putty in squares n
exc 0.5 sq. m in each

pane
16007 Ditto, but exc 0.5 sq. m

in each pane

fdlh eksVkbZ ds
'kh'ks jfgr
3.0

4.0

5.0

6.0

Rs.

Rs.

Rs.

Rs.

417.60

470.50

533.80

590.20

Rs.
71.00
181.30

izfr oxZ ehVj

16006 fiu 'kh"kZ fdLe ds 0-5 oeh


ls vuf/kd fpf=r 'kh'kksa dks
rsy ih lfgr pkS[kVs esa
yxkuk
16007 mi;qZDr] ysfdu izfr Qyd
0-5 oeh ls vf/kd

302

SECTION 16

SECTION 16GLAZING
[k.M 16&'kh'ks yxkuk
WIRED CLASS AND WIRED FIGURED GLASS
rkjh 'kh'kk rFkk rkjh fpf=r 'kh'kk
PER SQUARE METRE

n exc 0.5
sq.m

Exc 0.5
Exc 0.75
Exc 1.00
but n exc but not exc but n exc
0.75 sq m
1.0 sq m
1.5 sq.m

0-5 oeh
ls vuf/kd 0-5 oeh ls 0-75 oeh ls 1-0 oeh ls
vf/kd o
vf/kd o
vf/kd o
0-75 oeh ls 1-0 oeh ls 1-5 oeh ls
16008 Rough cast wired
vuf/kd
vuf/kd
vuf/kd
glass, 6.4mm thick
and glazing with oil
putty in square

1-5 oeh
ls
vf/kd

Rs.

Rs.

Rs.

Rs.

Rs.

954.20

961.30

1003.00

1056.80

1133.90

16009 Ditto, except wired

glass

149.30

144.70

139.30

140.33

16010 Rough cast, wired


figured glass, 6.4mm
thick and glazing with

oil putty in squares

830.80

837.90

881.20

921.70

16011 Ditto, except wired

figured glass

149.30

144.70

139.30

140.30

izfr oxZ ehVj

Exc 1.5
sqm

16008
16008:{k x<kbZ ds rkjh 6-4
feeh- eksVs 'kh'kksa dks ih
lfgr pkS[kVs esa yxkuk

16009
16009mi;qDZ r ysfdu rkjh 'kh'kksa
jfgr
138.90
16010
16010:{k x<+s gq, rkjh fpf=r
6-4 feeh eksVkbZ ds 'kh'ks
rsy ih ls pkS[kVs esa

981.20
yxkuk
16011
16011mi;qDZ r] rkjh fpf=r 'kh'kk
138.90
jfgr

HEAT ABSORBING GLASS & REFLECTIVE SOLAR CONTROL FILM


rki 'kks"kd 'kh'kk vkSj ijkcrhZ lkSj fuxzg f>Yyh
Exc 1.5 sqm

PER SQUARE METRE


16012 Heat absorbing glass, 3mm thick and
glazing complete with beads fixed

with brass screws


16013 Ditto, 5mm thick ditto
16014 Ditto, 6mm thick, ditto

1-5 oeh ls vf/kd


Rs.

16013 mi;qZDr] 5 feeh eksVk] mi;qZDr


16014 mi;qZDr] 6 feeh eksVk] mi;ZqDr

16015 Solar control film 25 micron reflective


type sticked to glass panes as per

instructions of manufacturers

292.00

16016 Ditto but 50 micron thick ditto

550.50

izfr oxZ ehVj


16012 rki 'kks"kd 3 feeh eksVs 'kh'ks dks ihry ds ispksa
ls chM yxkdj iw.kZ djuk

16015 25 ekbksu dh lkSj fuxzg ijkcrhZ f>Yyh] fuekZrk


ds fcfunsZ'kksa ds vuqlkj 'kh'ks Qydksa ls yxkuk

16016 mi;qZDr 50 ekbksu eksVh mi;ZqDr

303

SECTION 16

SECTION 16GLAZING
[k.M 16&'kh'ks yxkuk
MISCELLANEOUS
fefJr
izfr oxZ ehVj
Add to items 16001 to 16011 for:
1-5 oeh ls vf/kd tksM+sa en 16001 ls 16011 esa bl gsrq%
16017 Glazing with beads fixed with metal
16017 /kkrq ds isuy fiuksa ls chM+ lfgr 'kh'kk yxkuk
Rs.
panel pins (beads to be measured
chM dks **dsoy vkiwfkZ** ds vUrxZr vyx ls ekik

separately as 'supplied only')

tk;sxk
PER SQUARE METRE

Exc 1.5 sqm

16018 Ditto, fixed with brass screws (ditto)

16018 mi;qZDr] ihry ds ispksa ls yxkuk] mi;qZDr

16019 Oil putty glazing with spring clips in

metal surrounds

16019 /kkrq ds izfros'k esa dekuh fDyi dSph lfgr rsy

ih ls 'kh'ks yxkuk

GLAZING IN REPAIRS
ejEerksa esa 'kh'ks yxkuk
(a) The rates for 'glazing in repairs' include for hacking
out old broken glass, cleaning rebates in preparation
for reglazing carefully, taking out beads, removing
any serviceable glass to store and rubbish off the
premises; and also painting/oiling new putty to
match existing painting/oiling.
(b) Reglazing shall be measured as new work.
PER SQUARE METRE
16020 Hacking out old broken glass (any
thickness, size, quality or description)
from wooden frames or stone, concrete
or brick surrounds, glazed with putty

or fixed with beads


16021 Ditto from metal frame including
punching or drilling out old glazing
pins/spring clips and providing and

fixing new ones


16022 Deduct from item 2250 if glass is re
moved from patent glazing bars

d **ejEerksa esa 'kh'ks** dh njksa esa] iqjkus VwVs 'kh'kksa dks fudkyuk]
fjDr gq, LFkkuksa dks lko/kkuh iwoZd lkQ djuk nksokjk 'kh'ks]
yxkus gsrq] chMksa dks fudkyuk] mi;ksxh 'kh'kksa dks Hk.Mkj esa
tek djuk] rFkk eyos dks dk;Z LFky ls gVkuk( vkSj fo|eku
jax jksxu@rsy ds feyku ds fy, ubZ ih esa jax@rsy feykuk
'kkfey gSA
[k nksckjk 'kh'ks yxkus ds dk;ksZ dks u;s leku ekik tk;sxkA

izfr oxZ ehVj


1-5 oeh ls vf/kd 16020 ydM+h ds pkS[kVksa ;k iRFkj dahV ;k bZV ds
Rs.
pkS[kVksas ls iqjkus VwVs 'kh'ks fdlh Hkh eksVkbZ] eki]
ekud] ;k fooj.k ds fudkyuk rFkk ih ls ;k

chM yxkdj 'kh'ks yxkuk


55.50
16021 mi;qZDr] fdUrq /kkrq ds pkS[kVs esa ls] fiu@dekuh
dks Nsn djds ;k cjes ls dkVdj fudkyuk rFkk

u;s 'kh'kksa dh O;oLFkk djuk vkSj yxkuk


78.10
Exc 1.5 sqm

16023 Taking out old serviceable glass of any


description, from old wooden or metal
frames, or stone, concrete or brick surrounds, any thickness or size; hacking
out old putty or removing beads etc,
including making good breakages
in taking out and handling removing

to store or stacking for reuse

78.80

16022 en 2050 esa ls ?kVk;sa ;fn 'kh'kk /kkrqbZ 'kh'ks dh

ikh ls fudkyk gksA


16023 fdlh Hkh fooj.k ds iqjkus mi;ksxh 'kh'kksa dks] iqjkus
ydM+h ;k /kkrq ds pkS[kVks]a ;k iRFkj] dahV ;k bZVksa
ds fdlh Hkh eksVkbZ ;k eki ds ?ksjksa ls fudkyuk]
iqjkuh ih dks [kqjpuk ;k chM vkfn dks gVkuk]
fudkyus vkSj laHkkyus ds e/; gqbZ VwVu dks Bhd
djus lfgr] Hk.Mkj esa igqpkuk ;k nqckjk iz;ksx ds

fy, tek djuk

16024 Deduct from item 2253 if glass is


removed from patent glazing bars

26.20

16024 en 2253 esa ls ?kVk;sa ;fn 'kh'kk /kkrqbZ 'kh'ks dh

iRrh ls fudkyk gks

28.50

304

SECTION 16

SECTION 16GLAZING
[k.M 16&'kh'ks yxkuk
GLAZING IN REPAIRS - Contd...
ejEerksa esa 'kh'ks yxkuk tkjh
PER RUNNING METRE

M&L

16025 Securing glass of any description lkexzh ,oa Je


in existing wooden frames glazed
with putty/ beads including
removing loose or decayed putty/
beads, painting/oiling one coat on
rebates, grooves, reputtying and
painting/oiling puttied surface to
match existing work (New length
of frame reputtied shall be

measured)
16026 Ditto, but securing glass in metal

frames

Fixing only

dsoy LFkkiu

Rs.

Rs.

13.20

6.80

10.60

6.80

iz f r ehVj
16025 fo|eku ydM+h ds pkS[kVksa esa ih@chM
esa yxs 'kh'kksa dks lqjf{kr j[krs gq, <hyh
;k xyh gqbZ ih@chM gVkuk] jksxu@rsy
dh ,d ijr njkjksa] Nsnksa esa Hkjuk rFkk
fo|eku dk;Z ls esy djrs jax@rsy
dh ih yxkuk nqckjk ih yxs pkS[kVs

dh ubZ yEckbZ dks ekik tk;sxk


16026 mi;qDZ r] ysfdu /kkrq ds pkS[kVs ls 'kh'ks

izkIr djuk

LABOURS ON GLASS
'kh'ks dk Je

bu njksa esa VwVu dk tksf[ke c {kfr 'kkfey


gSA

The rates are inclusive of risk of breakage


and also wastage.
PER RUNNING METRE

16027 Grinding, polishing and


rounding off edges of glass, any

type

16028 Circular cutting on glass n exc

4 mm thick

N exc 4mm
thick

Exc 4 but n exc


8mm thick

eksVkbZ 4 feeh eksVkbZ 4 feeh ls


ls vf/kd ugha vf/kd ysfdu 8 feeh
ls vf/kd ugha
Rs.

Rs.

13.90

18.50

Sheet or
figured glass

Wired or wired
figured glass

pknj ;k fpf=r
'kh'kk

rkjh ;k rkjh
fpf=r 'kh'ks

Rs.

Rs.

27.90

39.10

iz f r ehVj

16027 f?klkbZ djuk] ikfy'k djuk vkSj


fdlh Hkh izdkj ds 'kh'ks ds fdukjksa

dks xksy cukuk

16028 4 feeh ls vuf/kd 'kh'ks dh pkdkj

dVkbZ djuk

305

SECTION 16

SECTION 16GLAZING
[k.M 16&'kh'ks yxkuk
LABOURS ON GLASS - Contd...
'kh'ks dk Je tkjh
EACH

N exc 4mm
thick

iz R ;s d

Exc 4 but n exc


8mm thick

eksVkbZ 4 feeh eksVkbZ 4 feeh ls


ls vf/kd ugha vf/kd ysfdu 8 feeh
ls vf/kd ugha
16029 Drilling hole in glass, any type,
dia of hole n exc 12mm

Rs.

Rs.

3.40

5.70

16029 fdlh izdkj ds 'kh'ks esa cjes ls 12

feeh rd ds O;kl ds Nsn djuk

MATERIALS (Supplied only)


lkexzh dsoy vkiwfkZ
PER SQUARE METRE

izfr oxZ ehVj

Thickness in mm

eksVkbZ feeh esa


3-0
4-0
4-8

16030 Sheet glass, ordinary


2-0
2-5
5-5
6-3 16030
quality, in squares n
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
exc 0.5 sq. m each

305.50 340.70 387.70 446.50 517.00 611.00 675.60


pane
16031
16031 Ditto, exc 0.5 sq. m
323.10 350.10 396.00 452.40 528.70 616.90 681.50
each pane

lk/kkj.k dksVh ds pkSdksj


'kh'ks ftldk izR;sd Qyd
0-5 oeh- ls vf/kd gks
mi;qZDr] izR;sd Qyd 05 oeh- ls vf/kd

16032 pquh gqbZ ekudh ds pgjh


pkSdksj 'kh'ks ftldk izR;sd
Qyd 0-5 o-eh- ls vf/kd

376.00 423.00 484.10 559.30 616.90 752.00 840.10


u gks
16033 mi;qZDr] izR;sd Qyd 016033 Ditto, exc 0.5 sq m each
5 oeh ls vf/kd

401.90 434.70 493.50 558.10 757.90 761.40 846.00


pane

16032 Sheet glass, selected


quality, in squares n
exc. 0.5 sq. m each

pane

Thickness in mm

eksVkbZ feeh esa


3.0
16034 Figured glass, pinhead
Rs.
type in squares n exc 0.5 sq.
346.60
m each pane
16035 Ditto exc 0.5 sq. m each pane

352.50
16036 Heat absorbing glass, any
840.10
size

4.0

5.0

6.0

Rs.

Rs.

Rs.

399.50

499.40

628.60

408.90

546.40

652.10

945.90

1010.50

1274.90

16034 fpf=r] fiu'kh"k fdLe ds pkSdksj


'kh'ks ftldk izR;sd Qyd 0-5

oxZehVj ls vf/kd u gksA


16035 mi;qDZ r] izR;sd Qyd 0-5 oxZeh- ls

vf/kd
16036 rki 'kks"kd 'kh'ks fdlh Hkh uki esa

306

SECTION 16

SECTION 16GLAZING
[k.M 16&'kh'ks yxkuk
MATERIALS (Supplied only) - Contd...
lkexzh dsoy vkiwfkZ tkjh
In Squares

oxkZdkj :i esa

PER SQUARE METRE


N exc 0.5 Exc 0.5
sq.m
but n exc
0-5 oeh 0.75 sq m

Exc 0.75
but n exc
1.0 sq m

izfr oxZ ehVj


Exc 1.00
but n exc
1.5sq. m

ls vuf/kd 0-5 oeh ls 0-75 oeh ls 1-0 oeh ls


vf/kd ij vf/kd ij vf/kd ij
0-75 oeh ls 1-0 oeh lss 1-5 oeh ls
vuf/kd
vuf/kd
vuf/kd
16037 Rough cast wired
glass, 6.4 mm thick
16038 Rough cast wired
figured glass, 6.4

mm thick

1-5 oeh
ls
vf/kd

Rs.

Rs.

Rs.

Rs.

Rs.

804.90

816.60

863.60

916.50

957.60

16037 vle x<+s rkjh 'kh'ks 6-4

feeh eksVs

804.90

16038 vle x<s+ rkjh fpf=r

'kh'ks] 6-4 feeh eksVs

681.50

693.20

PER K G
16039 Oil Putty

Exc 1.5
sqm

740.20

781.40

izfr fdyks xzke

Rs.

29.40

PER SQUARE METRE

Rs.

16040 Solar control film 25 micron reflective


type (gareware sun control or equiva
lent)

16041 Ditto 50micron thick ditto

282.00
540.50

16039 rsy ih

izfr oxZ ehVj


16040 lkSj fuxzg ijkcrhZ fdLe dh f>Yyh 25 ekbksu
/kwijks/kd ;k led{k

16041 mi;qZDr 50 ekbksu

307

SECTION 17

SECTION 17PAINTING
[k.M 17&jks x u djuk
SPECIAL CONDITION
fo'ks"k 'krsZ
17.1 Measurements
17.1.1 No deductions shall be made for openings n exc 0.5
sq. m each, and no addition shall be made for
painting to beading, moulding, edges, jambs, soffits,
cills. etc. of such openings.
17.1.2 Area of uneven surfaces shall be converted into
equivalent plain area in accordance with the
following table:

17-1 eki
17-1-1 dVkSrh ugha gksxh ,sls eks[kksa ds fy;s tks 0-5 oeh- ls vf/kd
u gksa] vkSj uk gh bu eks[kksa dh xksVu] >qdkoksa] fdukjksa]
esgjko] nsgyh vkfn dh jaxkbZ tksM+h tk;sxhA
17-1-2 vlery {ks= mlds cjkcj ds lery {ks= esa fuEufyf[kr
lkj.kh ds vuqlkj ifjofrZr dj fn;k tk;sxk%

EQUIVALENT PLAIN AREAS OF UNEVEN SURFACES

vlery lrgksa dk leku lery {ks=

No. Description of
work

How measured

Multiplying
factor

Panelled or
framed and
braced or ledged and battened or ledged, battened
and braced
joinery.

Measured flat (not 1.30 (for each


girthed) including side).
chowkat or frame.
Edges, chocks,
cleats, beads,
etc, shall not
be measured
separately.

Flush Joinery.

Ditto

la1
1

dk;Z dk fooj.k
2
fnYys ;k pkS[kVs
vkSj cU/ku ;k]
iq'rk vkSj iV~Vhnkj
iq'rk ih vkSj
caf/kr tqMk+ bZA

1.20 (for
each side).

Hkjoka tqMk+ bZA

Fully gauzed or Ditto


glazed joinery

0.80 (for each


side).

mi;qZDr

Partly panelled Ditto


and partly glazed or gauzed
joinery.

1.00 (for each


side).

Fully venetia- Ditto


ned or louvred
joinery.

1.80 (for each


side).

iw.kZ tkyhnkj ;k
'kh'ks dh tqM+kbZ
vkaf'kd fnYys vkSj
vkaf'kd 'kh'ks ;k
tkyh dh tqM+kbZA
iw.kZ vja/kd ;k
ja/kjh tqMk+ bZA

Weather
Boarding.

Measured flat
(not girthed) supporting Frame
work shall not
be measured
separately.

1.20 (for each


side).

_rq QjescanhA

likV eisxk ?ksjs 1-80 gj ,d


esa ugha pkS[kVs rjQA
vyx ls ugha
eisxsa

Wood shingle
roofing.

Measured flat (not 1.10 (for each


girthed).
side).

Boarding with Measured flat


cover fillets and (not girthed).
match boarding.

likV eisxh
?ksjs esa ugha
mi;qZDr

Tile and slate


battening.

ydM+h ds r[rk
NknuA
if;ksa ds lkFk
Qjescanh vkSj
feyku r[krsA
Vkby vkSj LysaV
ihnkjA

1.05 (for each


side).

Measured flat over 0.80 (for


all, no deduction
painting all
shall be made for over).
open spaces.

8-

dSls eisxk
3
likV uisxk
?ksjs esa ugha
pkS[kV ;k
pkS[kV lfgr@
fdukjs vksj]
xksVu vkfn
vyx ls ugha
eisxAas
mi;qZDr

xq.ku HkkT;
4
1-30 gj ,d
rjQA

1-20 gj ,d
rjQA
0-80 gj rjQ

mi;qZDr

1-00 gj ,d
rjQA

mi;qZDr

1-80 gj ,d
rjQ

1-10 gj ,d
rjQA
1-05 gj ,d
rjQA

laiw.kZ likV
0-80 iwjs LFky
eisxh] [kqy
jksxu ds fy,A
LFkkuksa dh dVkSrh
ugha gksxh

308

SECTION 17

SECTION 17PAINTING
[k.M 17&jks x u djuk

10 Trellis (or
jaffri) work one
way or two way

SPECIAL CONDITION
fo'ks"k 'krsZ
1
2
3
4
Measured flat
2 (for
10
tkyh ;k tkQjh
overall; no
painting all
dh ,d vksj ;k
deduction shall be over).
nksuksa vksj dk;ZA
made for open
spaces; supporting
members shall not
be measured
separately

11 Guard bars.
balustrades.
gratings, grills,
expanded metal
and railings.

Ditto

1 (for
painting all
over).

11

12 Gates and open


palisade fencing
including
standards.
braces, rails.
stays, etc.

Measured flat
overall; no
deduction shall be
made for open
spaces; supporting
members shall not
be measured
separately (See note
below)
Measured flat

1 (for
painting
all over).

12

2 (for each
side).

13

14 Steel rolling
shutters.

Measured flat (size 1.10 (for


of opening) jamb
each side).
guides, bottom rail
and locking
arrangement, etc.
shall not be
measured separately.
(Top cover be
measured
separately).

14

15 Plain sheet steel


doors and
windows.

Measured flat (not


girthed) including
frame, edges etc.

1.10 (for
each side).

15

16 Fully glazed or
gauzed steel
doors and
windows.

Ditto

0.50 (for
each side).

16

17 Partly panelled
and partly
glazed or
gauzed steel
doors.

Ditto

0.80 (for
each side).

17

18 Collapsible
gate.

Measured flat (size 1.50 (for


of opening)
each side).

18

13 Carved or
enriched work.

3
laiw.kZ likV
eisaxh( [kqys LFkkuksa
dh dVkSrh ugha
gksxh lgk;d
lkexzh vyx ls
ugha eisaxsa
mi;qZDr

4
2-00 laiw.kZ
jksxu ds fy,

lqj{kk lyk[ksa]
ckjts] tkfy;ka
lfj;k tkyh]
izlkj/kkrq vkSj
vxZfu;kaA
QkVd vkSj [kqys mi;qZDr] uhps uksV
dV?kjs] ck<+ lh/ks ns[ksa
M.Ms iVs] yksgs dh
vkMsa] lgkjs vkfn
lfgrA

1-00 laiw.kZ
jksxu ds fy,

uDdkjhnkj ;k
lq'kksfHkr dkeA
yksgs ds jksfyax
'kVjA

2 gj ,d
rjQ
1-10 gj
,d rjQ

le yksgs dh
pknjds njokts
vkSj f[kM+fd;kaA
iw.kZ 'kh'ksnkj ;k
tkyhnkj njokts
vkSj f[kM+fd;kaA
vkf'kd fnYys o
vkaf'kd 'kh'ks ;k
tkyhnkj yksgs ds
njoktsA
fleVoka QkVdA

likV eisaxsa

1-00 iwjh jaxkbZ


ij

likV eisaxs eks[ks


dh eki ik[ks
ekxZn'kZd ry dh
jsy] rkyk yxkus
ds izcU/k vkfn
vyx ls ugh
eisaxsa mij dk
<Ddu vyx ls
eisxk
likV eisaxs ?ksjs
1-10 gj
esa ugha pkS[kV
,d rjQ
fdukjs vkfn lfgr
mi;ZqDr
0-50 gj ,d
rjQ
mi;ZqDr

0-80 gj
,d rjQ

likV eisxsa eks[ks


dh eki

1-50 gj
,d rjQ

SECTION 17

309

SECTION 17PAINTING
[k.M 17&jks x u djuk
SPECIAL CONDITION
fo'ks"k 'krsZ
Note 1The height shall be taken from the bottom of the uksV 1 ry dh lcls uhps okyh iVjh ls pkbZ ekih tk;sxh ;fn
lowest rail, if the palisades do not go below it or from the dV?kjs blls uhps ugha x;s ;k dV?kjs ds fupys Nksj ls] ;fn og
lower end of palisades, if they project below the lowest
rail and upto the top of palisades, but not up to the top of lcls uhph iVjh ls uhps yxs gksa vkSj dV?kjs ds 'kh"kZ rd] fdUrq
MUMs ds 'kh"kZ rd ugha ;fn tks og dV?kjs ps gSaA
the standards, if they are higher than the palisades.
Note 2Where doors, windows, etc. are of composite uksV 2 tgka njokts] f[kM+fd;ksa vkfn tks bl lkj.kh esa fn;s x;s ds
types other than those included in this table different vfrfjDr lef"V rjg ds gSa] fHkUu&fHkUu Hkkx vyx&vyx muds
portions shall be measured separately with their
appropriate coefficients, centre line of common rail being lg lkexzh ds ekis tk;saxsA lk>s dh e/; js[kk dks nks Hkkxksa dks
foHkkftr djus okyh js[kk ekuk tk;sxkA
taken as the dividing line between the two portions.
Note 3Measurements of painting steel doors, windows, uksV 3 yksgs ds njokts] f[kM+fd;ka] fleVoka QkVd] jksfyax 'kVj
collapsible gates, rolling shutters, etc. as given in this table
vkfn ds jksxu dh eki bl rkfydk ds vuqlkj ;fn vko';d gqvk
shall be deemed to include painting, if required, of all
rks lHkh fQfVax dk leku dk jksxu Hkh mlh esa gqvk ekuk tk;sxkA
iron fittings in the same shade.
Note 4When two faces of a door, window; etc.. are to be uksV 4 tc njokts f[kM+dh ds iYys nksuksa vksj ls fHkUu&fHkUu jax
treated with different finishes, measureable under separate ls jksxu fd;s x;s gksa tks vyx&vyx enksa esa ekis tkus ;ksX; gSa rks
items, edges of frames and shutter shall be treated with
pkS[kVs ds fdukjs vkSj iYys dk mipkj funsfZ 'kr iwfrZ leku gksxk vkSj
the type of finish as directed and measurement thereof
shall be deemed to be included in the measurement of the mldh eki ml rjQ ds jax ds leku ekuh tk;sxhA
face treated with that finish.
Note 5In case where shutters are fixed on both faces of
a frame, measurement for the door frame and shutter on
one face shall be taken in the manner already described,
while the additional shutter on the other face shall be
measured exclusive of the frame.
Note 6Where shutter is provided with clearance
exceeding 15cm at top and/or at bottom, such openings
shall be deducted from the overall measurement and
relevant coefficients applied.
17.1.3 Corrugated steel or asbestos cement sheet surfaces shall
be measured flat (not girthed) and the areas obtained
shall be increased by the percentages given below:
(a) Corrugated asbestos cement sheets
20%
(b) Semi-corrugated asbestos cement sheets 10%
(c) Nainital pattern roof plain sheeting with
rolls
10%
(d) Ditto but with corrugated sheets
25%
(c) Corrugated steel sheets
, 14%
17.1.4 Painting upto 10cm in width or girth and not in
conjunction with similar painted work shall be
measured in running metres and shall include cutting
to line where so required; except that painting to
components of trusses, compound girders, stanchions,
lattices and similar work shall be measured in sq. m
irrespective of the size of girth of members.

uksV 5 ,slh voLFkk esa tgka iYys pkS[kVs dh nksuksa rjQ yxk;s x;s
gSa rks njokts ds pkS[kVs vkSj iYys ds ,d rjQ dh eki igys gh
fn, x;s fooj.kkuqlkj gksxh tcfd nwljh rjQ ds iYys dh eki
pkS[kVs dks NksM+rs gq;s gksaxhA
uksV 6 tc iYyk ij ls vfrfjDr 15 lseh- ls vf/kd LFkku NksMd
+ j
yxk;k x;k gks rks vkSj ;k uhps dh vksj ls ,sls eks[ks] lai.w kZ vkSj lacfa /kr lg
lkexzh ds eki esa ls ?kVk;sa tk;saxsA
17-1-3 iukjhnkj yksgs ;k vng lhesaV pknj dh lrg dks likV
ekik tk;sxkA ?ksjs esa ugh vkSj tks {ks=Qy vk;sxk mls
uhps fn;s x;s izfr'kr }kjk c<+k;k tk;sxkA
d iukjhnkj vng lhesaV pknjsa
20 izfr'kr
[k v/kZ iukjhnkj vng lhesaV pknjsa
10 izfr'kr
x uSuhrky rjhds dh lery pknj xksys lfgr 10 izfr'kr
?k mi;qZDr fdUrq iukjhnkj pknj lfgr
25 izfr'kr
M iukjhnkj yksgs dh pknjsa
14 izfr'kr
17-1-4 10 lseh- pkSMk+ bZ xksykbZ rd dk jksxu vkSj leku jksxu fd,
{ks= ds lkFk tqM+k ugha rks] ehVj esa ekik tk;sxk vkSj js[kk
rd dh dVkbZ 'kkfey gksxh] tgka vko';d gks flok; ih
ds Hkkx] lfEefyr xMZj] vk/kkj [kEHks rFkk leku dk;Z oeh
esa ekis tk;sx
a s fcuk mudh xksykbZ dh eki dk fopkj fd;sA

17-1-5 NksVh oLrqvksa vkSj ,slh lrgsa tks 0-1 oeh {ks=Qy ls vf/kd
u gksa vkSj leku dk;Z esa la;qDr ugha gksa rks mudh jksxu dk;Z
esa x.kuk gksxhA
17-2 njksa
17-2-1 njksa esa fuEu 'kkfey gSa%&
17.2.1 The rates include for:
(a) Use of all scaffoldings and cradles including hoisting d lHkh izdkj ds epku vkSj >yks] mij dks mBkus vksj fupkbZ ds
and lowering.
lk/kuksa dk iz;ksx 'kkfey gSA
17.1.5 Painting to small articles and to surfaces n exc 0.1
sq m in area, where not in conjunction with similar
painted work shall be enumerated.
17.2 Rates

310

SECTION 17

SECTION 17PAINTING
[k.M 17&jks x u djuk
SPECIAL CONDITION
fo'ks"k 'krsZ
(b) Taking down, cleaning as directed and refixing blinds [k funs'Z kkuqlkj insZ vkSj tqMu
+ kjks]a rLohjksa ds MUMs] dkjfu'k ds Nksj
and fittings, picture rods, cornice poles and small
vkSj Hkou fuekZ.k dh NksVh oLrqvksa tSls njoktksa dh xkaB]as iryh
items of builders hardware such as door knobs, finger
IysVsa ikfjokfjd fpUg] dkVs vkfn ftu ij jksxu ugha djuk gS
plates, escutcheons, hooks etc. which are not required
dks mrkjuk o nksokjk yxkukA
to be painted.
+ kjks]a QuhZpj vkfn dks pknj ;k vU; vkoj.kksa
(c) Use of dust sheets and other coverings for the x lkt leku] tqMu
protection of fixtures, fittings, furniture, etc.
ls <aduk
(d) Shifting of movable cupboards and furniture as ?k pyk;eku vyekfj;ksa vkSj QuhZpj dks tSlh vko';drk gks
gVkuk vkSj ;FkkLFkku j[kukA
required and replacing in position.
(e) Work in patches (over one square metre each) M isou ds dk;Z esa izR;sd ,d oeh fo|eku dk;Z ls feyku vkSj
including matching with existing work and marrying
fdukjs feykuk 'kkfey gSA
in at the edges.
(f) Removing all splashes, drops, dirt, etc. and leaving p lHkh NhaVs] cwUn] /kwy vkfn lkQ djuk vkSj dk;ZLFky dks lkQ
premises in a clean state.
lqFkjk cukdj NksMu+ k
17.2.2 Preparation of SurfacesRates for preparation of 17-2-2
17-2-2lrg rS;kj djuk lrg rS;kj djus esa ml izdkj ds dk;Z esa
surfaces include for all necessary preparatory work
vko';d lHkh rS;kjh 'kkfey gS vkSj ydM+h dh lrg dh njksa
required for the respective type of surfaces and in
ds fo"k; esa jksxu dks NqMk+ us es]a jxM+kbZ] f?klkbZ] tykbZ 'kkfey
case of wood surfaces the rates include for knotting
gS rFkk tLrh lrg ij jslk;fud ?kksy p<+kus dk dk;Z vyx
and stopping. Burning off or removing paint and
ls ekik tk;sxkA
applying mordant solution to galvanised surfaces,
where indicated, shall, be measured separately.
17.2.2.1 For new or previously untreated surfaces of fibre
building boards, plywood, block boards, particle
boards and the like, no preparation except dusting
and cleaning is necessary. Payment under
preparation of surfaces will not, therefore, be made
for such boards.
17.2.3 Painting in Repair Work in Patches upto one
square metre each
(a)
Each patch shall be measured under the followiing
categories and paid for at the appropriate rates for
new work, with an addition of 50 per cent to cover
cost of matching with existing work and marrying
in at the edges, etc.
(1) Patch n exc 0.1 sq. m. shall be measured as 0.1sq.m.
(2) Patch exc 0.1 sq. m. and n exc 0.5 sq. m shall be
measured as 0.5 sq. m.

17-2-2-1 uohu ;k igys jksxu jfgr bekjrh js'ks ds r[rks]a IykbZ]


l[r r[rs] ,d Hkkxh; r[rs rFkk blh izdkj ds dk;Z ds fy,
flok; /kwy mM+kuk vkSj lQkbZ ds vkSj rS;kjh dh vko';drk
ugha gSA vr% ,sls r[rksa ij rS;kjh ds vUrxZr fdlh Hkqxrku dh
vko';drk ugha gSA
17-2-3 ejEer ds dk;Z esa izR;sd ,d oeh ds isou ij jksxu djuk

d izR;sd isou dks fuEu Js.kh;ksa ds vUrxZr ekik tk;sxk rFkk u;s
dk;Z dh mi;qDZ r njksa ds vUrxZr Hkqxrku 50 izfr'kr vfrfjDr
lfgr gksxk tks fo|eku ds lkFk feyku djus vkSj fdukjksa dks
jaxus esa vkus O;; dh HkjikbZ ds fy, gksxk%&
1 0-1 oeh ls vuf/kd isou dks 0-1 oeh ekik tk;sxkA
2 0-1 oeh ls vf/kd vkSj 0-5 oeh ls vuf/kd isou dks 0-1
oeh ekik tk;sxkA
(3) Patch exc 0.5 sq. m and n exc 1 sq. m shall be
3 0-5 oeh ls vf/kd vkSj 1-0 oeh ls vuf/kd isou dks 0-1
measured as 1 sq. m.
oeh ekik tk;sxkA
(4) Area exceeding 1 square metre shall be
4 ,d oeh ls vf/kd {ks=Qy okys isou dks u;s dk;Z esa ekik tk;sxkA
measured as new work.
(b) New work in small quantities on isolated [k NksVh ek=k ds ,dy lrg ij u;s dk;Z isou dk;Z ugh gksaxsA

surfaces shall not be treated as work in patches.


17.2.4 Painting on Bolt Heads, Nuts and Washers,
Hinges, etc.Shall only be allowed if these articles
are picked out in a different tint to the adjacent work.
When so painted, the last coat only on these articles
shall be paid for.
17.2.5 Cutting to Line;In painted work, cutting to line will
be allowed if two portions of plain surface are painted
in different tints. Cutting to line will not be allowed
for edges of architraves finishing against distempered
or lime washed walls nor on doors sashes, etc. painted
one side only or in different tints inside and outside.
Cutting to line shall not be allowed also where the
same is included in the rates such as in the case of
items for work not exceeding 10 cm width or girth.

17-2-4 oksYV 'kh"kZ] uV vkSj cklj] dCts vkfn bu dk jksxu


rHkh fu;fer gksxk ;fn ;g oLrq;sa lkFk ds dk;Z esa fHkUu jax
ds gksaA tc bu ij jksxu gksrk gS rks vafre ijr ds fy, gh
Hkqxrku gksxkA
17-2-5 js[kk dVkbZ rHkh Lohd`r gksxh tc js[kk] ds nksuksa vksj fHkUu
jax dk jksxu gks] js[kk dh dVkbZ Hkkxksa dsas fdukjksa fMLVSEij dh
iwfrZ ;k pwus dh /kqyh nhokjksa ds fy;s Lohd`r ugha gS vkSj uk
gh njoktksa pkS[kVksa vkfn ,d rjg ds jksxu ;k vUnj ;k okgj
fHkUu&fHkUu jax ds jksxu ij Lohd`r gSA js[kk dh dVkbZ ogka
Hkh Lohd`r ugha gS tgka og mu njksa esa 'kkfey gSa tSls ,sls dk;Z
tks 10 lseh de pksMs ;k xksy gSaA

311

SECTION 17

SECTION 17PAINTING
[k.M 17&jks x u djuk
PAINTING WOOD AND WOOD BASED SURFACES
ydMh vkSj ydMh vk/kkfjr lrgksa dh jaxkkbZ
17.2.6 Flag staffs, etc.The rates for painting do not 17-2-6 /ot [kEHks vkfn /ot [kEHkksa dh jksfLlgksa >a>jh ugha yksgs
apply to flag staffs pole aerials (not latticed),
dh fpefu;ka] nwf/k;k jks'kuh dh tkfy;ka] aph jks'kfu;ksa ds
steel chimneys, flood light towers, overhead
iYyw] ehukjksa vkSj leku dk;Z tks igys gh yxs gS] vkSj jksxu
electric masts, spires and similar work, already
ds dk;Z mUgsa uhpk ugha fd;k tk ldrk] muij jksxu dh njsa
fixed and cannot be lowered for painting.
ykxw ugha gksaxhA
Preparation of

PER SQUARE METRE

Priming coat

Synthetic
enamel
(ordinary
New or Old
Aluminium Pink Zinc
previo- painted primer
primer Chrome tint)
usly un- surfaces
primer (each
coat)
treated
flUFkh
surfaces

RkS;kjh

vLrj rg dh

ubZ ;k
iqjkuh
igys jax jaxhu
lrgsa
any u gh
not gqbZ lrgsa

17001 Surfaces
of
description,
otherwise descri-bed,
Rs.
over 10cm width or
6.00
girth
17002 Ditto, but except
6.00
paint

vY;wfefu;e xqykch ftad


vLrj
vLrj kse
vLrj

Rs.

Rs.

Rs.

Rs.

8.10

13.40

12.70

8.10

7.90

7.90

,usey
lk/kkj.k
jax izR;sd
rg
17001 fdlh Hkh izdkj dh lrgsa
;fn vU;Fkk fu:ifr ugh
Rs.
gS vkSj 10 lseh- ls vf/kd
19.60
pkSM+h ;k eksVh gSaA
17002 mi;ZDq r] ysfdu jax jfgr
9.80

izfr 10 ehVj

PER 10 RUNNING METRES


17003 Surfaces
of any
description n exc
10cm width or girth
when unconnected
with other painting or
when painted in
3.50
different tint
17004 Ditto but
except
3.50
paint

3.50

10.20

9.70

13.90

3.50

6.10

6.10

7.90

17003 fdlh Hkh izdkj dh lrgsa


10 lseh- ls vf/kd pkSMh+
;k eksVh tc vU; jaxkkbZ
ls vlEca/k gksa ;k tc
vU; jax esa jaxh gks
17004 mi;ZDq r] ysfdu jax jfgr

izfr 100 vad

PER 100 NOS.


17005 Small articles such as
rafter feet, brackets or
cantilevers n exc 30 cm
projection and blocks,
labels, etc. n exc 0.1 sq.
57.90
m each
17006 Ditto, but except
57.90
paint

87.00

156.90

149.50

87.00

99.10

99.10

17005 NksVh oLrq;sa tSls cYrs


dk ikn] ?ksjs ;k ?kksfM+;ka
30 lseh- ls vuf/kd foLrkj
okys vkSj 0-1 oeh ls vf/kd
226.90
f?kjfu;ka o fpfIi;ka
17006 mi;qDZ r] ysfdu jax jfgr
132.20

izfr oxZ ehVj

PER SQUARE METRE


17007 Filler coat with grey
filler or liquid wood
filler, transparent, and
bringing forward
surfaces to smooth

even finish

izfr oxZ ehVj

M&L

Except filler

lkexzh ,ao Je

Hkjko jfgr

Rs.

Rs.

19.80

8.00

17007 Hkjkoh rg] Hkwjh Hkjkoh ;k


ydM+ h rjy Hkjko]
ikjn'kZd lfgr vkSj
lrgksa dks fpduh ,dlkj
vkHkk iw.kZ cukuk

312

SECTION 17

SECTION 17PAINTING
[k.M 17&jks x u djuk
CRESOTING, OILING, ETC.
jaxghu yksgoku] rsy iqrkbZ vkfn

Hkqxrku izR;sd rnuUrj rg ds fy, en 17008 vkSj 17009 dh njksa


dk 2@3 dh nj ls gksxkA

Payment for each subsequent coat shall be made at two-thirds


the rates given against items 17008and 17009.
PER SQUARE METRE
17008 Preparing surfaces of wood
and wood based materials,
new or old, of any description
and girth, not otherwise

described and treated with


17009 Tiles or slate battens, any size
and spacing, prepared and
treated all over (measured
overall on one side only,

spaces not deducted) with

17010 Preparing surfaces of wood


and wood based materials,
steel and iron work, new or old,
of any description and girth,
not otherwise described, and
treated with tar or coal tar

black paint

Creosote

Raw
Except oil
linseed oil

jaxhu

dPpk
vylh rsy

rsy jfgr

Rs.

Rs.

Rs.

8.60

10.30

4.50

1700
170088

17009

12.00

9.40

5.60

M&L

Except
Preservative

lkexzh ,ao Je

j{kd inkFkZ jfgr

Rs.

Rs.

9.10

5.60

17010 ydM+h vkSj ydM+h ij vk/kkfjr lkexzh]


bLikr vkSj yksgk uohu ;k iqjkuk]
fdlh Hkh izdkj ;k eksVkbZ vU;Fkk
fu:fir ugha( lrgsa rS;kj djuk vkSj
rkjdksy ;k dkys jax ls mipkfjr

PER 100 NOS.


17011 Ditto, treating ends of posts,
backs of chowkats, etc., area
tarred exc 0.1 sq. m but n exc

0.5 sq. m each ditto


17012 Ditto, treating small articles
such as stop, covers, gully
gratings, holdfasts, ends of
posts, backs of chowkats, etc.,
area n exc 0.1 sq. m each, ditto

17011

506.90

225.60

183.70

112.80

17012

izfr 100 vad


mi;qZDr] [kEHkksa ds Nksj pkS[kV vkfn
ds fiNys Hkkxkas dk mipkj ij izR;sd
mipkfjr {ks=Qy 0-1 oeh ls vf/kd
ysfdu 0-5 oeh ls vf/kd ugha] mi;qDZ r
mi;qZDr] NksVh oLrqvksa ij mipkj
tSls fojke] Bddu] ukyhnkj tkfy;ka]
dkfV;ka] [kEHkksa ds Nksj] pkS[kV ds
fiNys Hkkx vkfn izR;sd dk {ks=Qy
0-1 oeh ls vf/kd ugha] mi;qDr
izfr oxZ ehVj

PER SQUARE METRE


17013 Preparing surfaces of timber
piles and diping in a hot
mixture of tar and creosote in
the proportion of 20 kg coal tar
pitch to 25 litres of creosote

oil, for 4 mins.

izfr oxZ ehVj


ydM+h vkSj ydM+h ij vk/kkfjr lkexzh]
uohu ;k iqjkuh] fdlh Hkh izdkj vkSj
eksVkbZ fd] tc rd vU;Fkk fu:fir u
gks lrgksa dh rS;kjh vkSj blds lfgr
mipkfjr
Vk;ysa ;k LysV ifV~V;ka fdlh Hkh uki
o vUrjky dh gj izdkj ls rS;kj vkSj
mipkfjr dsoy ,d vksj ls ekih
tk;sxh] vUrjky ugha ?kVsaxs

26.60

17014 Sanding newly tarred or painted surfaces

with clean sharp sand

5.00
Rs.
66.10

17013 ydM+h dh LFkw.kksa okyh lrgksa dks


rS;kj djus ds fy,] rkjdksy rFkk
yksgoku ds] 20 fdxzke rkjdksy rFkk
25 fyVj yksgou ds xeZ ?kksy esa
Mqcksuk

17014 rkjdksy jksxu ls iqrh ubZ lrg ij lkQ rst ckyw


fcNkuk

313

SECTION 17

SECTION 17PAINTING
[kaM 17&jksxu djuk
CLEAR FINISHES TO WOOD AND WOOD BASED SURFACE

ydM+h o ydM+h vk/kkfjr lrgksa dh LoPN ifj"d`fr

d LoPN ifj"d`fr esa rFkk fufnZf"Vr ,slh gh fufnZ"Vr rS;kjh]


lQkbZ] HkjkbZ] jxM+kbZ] HkjkbZ izR;sd rg ds ckn 'kkfey gSA

(a) The rates for clear finishes include such preparation,


cleaning, stopping and rubbing down after each coat,
stopping as specified.
(b) Small articles not exceeding 0.05 sq.m shall be measured
as 0.05 sq.m each.

[k NksVh oLrq,sa tks 0-05 oeh ls vf/kd ugha gS] 0-05 oeh
izR;sd ekih tk;sxhA

STAINING AND VARNISHING

vfHkjatu rFkk okfuZ'k dk;Z


PER SQUARE
METRE

Preparation of Sizing Filler coat

Staining

Varnishing

rS;kjh djuk

vfHkjatd

okfuZ'k

New or
previously
untreated surfaces

ljsl Hkjkoh rg
yxkuk

Old
treated
surfaces

Wood
filler
liquid
transparent

iqjkuh
ubZ ;k mipkjh
iwoZ
lrg
vuqipkjh
lrg

17015 Surfaces of any


description, over
10cm in width or

girth

17016 Ditto but except


size, wood filler,

stain or varnish

Thin Oil
varnish rsy
or lacquer or
she llac
varnish

ikjn'khZ
dk.B iryh
?kksy ySdj
;k piM+k

Rs.

Rs.

Rs.

Rs.

Rs.

7.70

8.60

8.00

16.90

10.10 9.30

8.90

9.80

3.40

5.30

8.00

Rs.

5.30

PER 10 RUNNING
METRES
17017 Surfaces of any
description, not
exc 10 cm in width
or girth when
unconnected
with other work
or pai-nted in
different tint
17018 Ditto but except
size, wood filler

stain or varnish

izfr oxZ ehVj

Spirit Under FinisfLifjV coating hing


vLrj coat
with
synthetic
varnish

Rs.

Rs.

vafre
rg
lay"s k.k
okfuZ'k 17015
fdlh Hkh fdLe dh
lfgr
lrg 10 lseh pkSMh+ ;k
Rs.
?ksjs esa

12.90 12.10

7.10

17016 mi;qDZ r fdUrq ljsl


jfgr] dk.B Hkjkok@
6.60
vfHkjatd ;k okfuZ'k
izfr 10 ehVj
17017 fdlh Hkh fdLe dh 10
lseh pkSMh+ ;k ?kuRo dh
lrg tc vU; dk;Z ls
vlac) ;k fHkUu jax ls
iqrh gqbZ

4.80

4.80

5.90

5.90

9.60

4.50

35.40

28.90

16.80 11.90

16.30 14.70

13.30 7.90

17018 mi;qZDr fdUrq ljsl


jfgr] dk.B Hkjkok
10.60 9.20
vfHkjatd ;k okjfu'k

314

SECTION 17

SECTION 17PAINTING
[kaM 17&jksxu djuk
POLISHING
ikfy'k djuk
PER SQUARE METRE
17019 Bees-wax polishing on
surfaces of any description,
width or girth including
cleaning and preparing the

surface
17020 All as item 17019 but on
surfaces, previously

polished
17021 French polishing on
surfaces of any description,
width or girth including
cleaning and preparing the
surface including a coat of
wood filler on new works
with two or more coats
17022 Ditto, but one or more coats

on old work

M&L

Except Polish

lkexzh ,oa Je

fcuk ikfy'k ds

Rs.

Rs.

38.50

21.40

19.90

10.60

izfr oxZ ehVj


17019 fdlh O;k[;k] pkSM+kbZ ;k eksVkbZ
dh lrg ij eD[kh ekse ls ikfy'k
djuk] lrg dh lQkbZ vkSj rS;kjh
lfgr
17020 lc en 17019 tSlk fdUrq iwoZ
ikfy'k dh gqbZ lrg ij
17021 fdlh O;k[;k] pkSMk+ bZ ;k eksVkbZ dh
lQkbZ vkSj rS;kjh lfgr rFkk dk.B
Hkjko dh ,d rg lfgr nks ;k vf/kd
ijr dh sUp ikfy'k djuk

45.30

40.90

35.80

31.50

17022 mi;qZDr] fdUrq iqjkus dk;Z ij


,d ;k vf/kd ijr

PAINTING BRICK, STONE, CONCRETE, ASBESTOS CEMENT OR PLASTER SURFACES

jksxu dk;Z] bZV] iRFkj] dahV] ,LoSLVl lhesaV ;k iyLrj dh lrg ij


PER SQUARE METRE

Preparation of
New or
Old
previPainted
ously
surfaces
Untreated iqjkuh
surfaces
jaxhu

Priming Synthetic
paints
enamel
plaster (ordinary
coat
tint)
vLrjh
(each
jksxu
coat)

iyLrj
rg

falFa kSfVd
,susey
lk/kkj.k
jax izfr
rg

Plastic
emulsion
(each
coat)

izfr oxZ ehVj

IykfLVd
,eY'ku
izfr rg

ubZ ;k iwoZ
vuqipkjh
lrg

lrg

17023 Surfaces of any


description over 10cm
girth or width, not

otherwise described

Rs

Rs.

Rs.

Rs.

Rs.

2.60

5.60

14.70

20.80

23.60

17023 fdlh O;k[kk dh 10 lseheksVh ;k pkSM+h lrg


vU;Fkk fufnZ"V u gks

17024 Ditto but except

paint

2.60

5.10

7.90

10.60

10.60

17024 mi;qZDr] fdUrq jksxu


jfgr

315

SECTION 17

SECTION 17PAINTING
[kaM 17&jksxu djuk
PAINTING BRICK, STONE, CONCRETE, ASBESTOS CEM PLASTER SURFACESContd...

jksxu dk;Z] bZV] iRFkj] dahV] ,LoSLVl lhesaV ;k iyLrj dh lrg ij tkjh
PER 10 RUNNING
METRES

Preparation of
New or
Old
previPainted
ously
surfaces
Untreated iqjkuh
surfaces
jaxhu

17025 Surfaces plain or


moulded, n exc 10cm
width or girth when
unconnected with
other painting or
when painted in a

different tint
17026 Ditto, but except

paint

Priming Synthetic
paints
enamel
plaster (ordinary
coat
tint)
vLrjh
(each
jksxu
coat)

iyLrj
rg

falFa kSfVd
,susey
lk/kkj.k
jax izfr
rg

Plastic
emulsion
(each
coat)

izfr 10 ehVj

IykfLVd
,eY'ku
izfr rg

ubZ ;k iwoZ
vuqipkjh
lrg

lrg

Rs

Rs.

Rs.

Rs.

Rs.

4.70

16.20

22.50

26.10

32.90

17025 lery ;k fpduh lrg]


tks pkSM+kbZ ;k eksVkbZ esa
10lseh- ls vf/kd u gks]
tc feyh u gks ;k fHkUu
jax dk jksxu fd;k gks

5.70

16.20

11.90

15.90

19.80

17026 mi;ZDq r] fdUrq jksxu jfgr

PER 100 NOS

izfr 100 vad

17027 Labels, etc, n exc 0.1


sq. m each, including
cutting in edges

29.10

61.80

17028 Ditto, but except


paint

28.60

61.80

17027 fpfIi;k vkfn izR;sd 0-1


o-eh- ls vuf/kd fdukjksa
dh dVkbZ lfgr
17028 mi;qDZ r] fdUrq jksxu jfgr

186.70

226.20

268.60

124.30

138.80

316

SECTION 17

SECTION 17PAINTING
[kaM 17&jksxu djuk
PAINTING STEEL AND IRON SURFACES

bLikr rFkk yksgs dh lrgksa ij jksxu dk;Z

vksyrh ?kkVh xVjksa o gkWij 'kh"kZ dh jaxkbZ dh njksa esa fudkydj lkQ
djuk o fLFkj djuk 'kkfey gSA

Rates for painting eaves or valley gutters and hopper heads


include for cleaning out same and strengthening joints of gutters
with red lead putty before painting.
PER SQUARE METRE

Preparation of

Synthetic
enamel
(ordinary
tint)

Black AlumiJapan nium


(each paint
coat) (each
coat)

New or Old Red Red Alumi- (each coat)


previo- painted lead oxide, nium flaFkSfVd
usly un- surfaces flanjw
zinc
red
,susey
treated iqjkuh
chrome oxide lk/kkj.k
surfaces jaxhu
yky vYeqfu& jax izfr

dkyk vYeqfu&
tkiku ;e
izfr jksxu
ijr izfr
ijr

ubZ ;k

Priming with

lrg

vkDftad

17029 Surfaces of any vmi&


description, over pkjh iwoZ
10cm in width or
girth,not otherwise Rs.
5.00
described

Rs.

Rs.

7.90

14.90 14.00

17030 Ditto, but except


5.00
paint

7.90

8.00

Rs.

8.00

;e
yky
vkDlkbM

ijr

Rs.

Rs.

16.70

19.60

14.10 15.20

170
29 fdlh Hkh o.kZu dh 10
17029
lseh pkSMh+ ;k eksVh
xksykbZ vU;Fkk of.kZr
ugha

11.90

10.60

17030 mi;qDr] jaxfgr

Rs.

Rs.

8.70

izfr 10 ehVj

PER 10 RUNNING
METRES
17031 Eaves gutter and
pipes any description, n. exc 60 cm
girth including
holderbats, distance
pieces, etc. (length
measured over
bends, branches
23.80
etc.)
17032 Ditto but except
23.80
paint
17033 Surfaces of any
description, n.exc
10cm in width or
girth when unconnected with other
painting or when
painted in a
different tint 6.00

izfr oxZ ehVj

17031 60 lseh vuf/kd ?ksjs


ds ikbi o vksyrh xVj
vUrjh idM+ [kaM vkfn
lfgr yEckbZ oSM]
'kk[kkvksa vkfn ds ij
ls ekih tk;sxh

36.70 60.50 57.30

83.90

64.30 68.70

36.70 37.50 37.50

50.50

50.20 42.50

17032 mi;qZDr jax jfgr

15.70 19.20

17033 fdlh o.kZu dh 10


lseh ls vuf/kd pkSMh+
;k eksVh lrg tc
vU; jksxu ls vlaca/k
;k vU; jax esa jaxh
gks

10.20 15.40 17.00

19.60

317

SECTION 17

SECTION 17PAINTING
[kaM 17&jksxu djuk
PAINTING STEEL AND IRON SURFACESContd...

bLikr rFkk yksgs dh lrgksa ij jksxu dk;Z tkjh


PER SQUARE

Preparation of

Synthetic
rS;kj djuk
vLrj ls
enamel
(ordinary
tint)
(each
New or Old Red Red Alumi- coat)
previous painted lead oxide, nium flaFkSfVd
untre- surfaces flanjw
zinc
red
,susey
ated
iqjkuh
chrome oxide lk/kkj.k
surfaces jaxhu
yky vYeqfu& jax izfr

ubZ ;k
vmi&
pkjh iwoZ
Rs.

17034 All as item 17033


but except paint 6.00

Priming with

lrg

vkDftad

;e
yky
vkDlkbM

Black AlumiJapan nium


(each paint
coat) (each
coat)

izfr oxZ ehVj

dkyk vYeqfu&
tkiku ;e
izfr jksxu
ijr izfr
ijr

ijr

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

10.20

9.60

12.00

10.80

12.20

12.70

17034 lc en 17033 tSlk


fdUrq jax jfgr

PER 100 NOS


17035 Small articles such as
metal switch blocks,
metal ceiling roses,
articles of builder's
hardware such as
door springs, hooks,
knobs, fasteners,
stays, locks, latches,
etc., straps to roof
trusses, gates and
similar arti-cles,
when unconne-cted
with other pain-ting
or when painted in a
23.80
different tint
17036 Ditto but except
23.80
paint
17037 Brackets or cantilevers
n. exc 30cm projection,
pintle hinges, gratings,
frames and similar
articles when unconnected with other
painting or when
painted in a different
84.60
tint
17038 Ditto but except
84.60
paint

izfr 100 vad

38.50

51.60

49.90

70.90

59.90

60.70

38.50

39.90

39.90

52.90

52.90

47.60

118.50 177.70 169.60

248.90

193.90 197.80

118.50 120.10 120.10

158.60

158.60 132.20

17035 NksVh phtsa tSls /kkrq


Lohp Cykd] /kkrq Nr
dVksjh bekjrh /kkrq
miLdj tSls }kj
dekfu;ka] gqd] ewB]
ca/kd] jksd] rkys]
tathj vkfn Nr dM+h
QkVd ds iV~Vs rFkk
vuq:i phtsa tgka
vU; ja x kbZ ls
vlac) ;k tgka fHkUu
jax esa jaxs gksa
17036 mi;qDZ r] fdUrq jax
jfgr
17037 30 lseh izlkj czfS dV
;k iz k Ir] dhyh
dCts] tkfy;ka] se
o vuq:i phtsa tgka
vU; ja x kbZ ls
vlac) ;k fHkUu jax
esa jaxs gksa
17038 mi;qDZ r] fdUrq jax
jfgr

318

SECTION 17

SECTION 17PAINTING
[k.M 17&jksxu dk;Z
SPECIAL PAINTING
fo'ks"k jksxu dk;Z

bu njksa esa rS;kjh dk;Z vkSj lrg dk vLrj.k 'kkfey ugha gS] tks fd
vyx ls ekik tk;sxkA

The rates do not include for preparation and priming of


surfaces, which shall be measured separately.

izfr oxZ ehVj

PER SQUARE METRE


Black
Heat
Fire
Acid
Except
bitumin- resisting resisting
resistant paint
ous paint
paint
paint
paint
(each
(each coat)
(each coat) (each coat) coat)
17039 Surfaces of any
description wood,
steel, iron, concrete,
brick, stone, etc.,
exceeding 10cm in

width or girth

dkyk
rksjdksyh
jksxu
izfr rg

rki
fua;=d
jksxu
izfr rg

vfXu
fu;a=d
jksxu
izfr rg

vEy
fu;a=dj
jksxu
izfr rg

Rs.

Rs.

Rs.

Rs.

15.20

21.60

PER 10 RUNNING
METRE
17040 Surfaces of any
description wood, steel,
iron, concrete, brick,
stone, etc. n exc 10cm

in width or girth

jksxu
jfgr 17039 fdlh Hkh O;k[;k dh ydM+h]
yksgs] bLikr] dahV] bZaV]
izfr
iRFkj vkfn dh 10 lseh- ls
rg
vf/kd pkSMh+ ;k eksVh lrg
Rs.
ij
11.90
izfr 10 ehVj

15.20

23.70

PER SQUARE METRE


Treating surfaces of wood, any
description, width or girth, with ready
mixed paint, matt black; each coat
Treating surfaces of steel and iron work,
any description, width or girth, with ready
mixed paint, dead black; each coat
Painting floors with ready mixed paint,

for use on floors; each coat


Painting hessian with ready mixed

paint, red oxide; each coat

Rs.

17040 fdlh Hkh O;k[;k dh]ydM+h]


bLikr] yksgs] dahV] bZaV]
iRFkj vkfn dh 10 lseh ls
vuf/kd eksVh ;k pkSMh+ lrg
12.70
izfr oxZ ehVj
ydM+h dh fdlh O;k[;k] pkSM+kbZ ;k eksVkbZ dh
lrg ij iwoZ fefJr gyds dkys jax dk mipkj]
izfr rg
bLikr rFkk yksgs ds dk;Z dh fdlh Hkh O;k[;k]
eksVkbZ ;k yEckbZ dh lrg ij iwoZ fefJr xgjs
dkys jax dk mipkj] izfr rg
Q'kZ ij iz;ksx okys iwoZ fefJr jax ls Q'kZ ij jax
djuk] izfr rg
yky vkDlkbM iwoZ fefJr jksxu ls eksVs diMs+ ij
jksxu djuk] izfr rgA

319

SECTION 17

SECTION 17PAINTING
[k.M 17&jksxu dk;Z
WRITING
fy[kkbZ
(a) Letters under 2cm height shall be measured as 2cm.
(b) Letters etc., shall be painted with thick paint, so that they
stand out boldly and solidly without showing signs of
brush marks, if necessary, they shall be repainted until the
desired result is obtained.
(c) Rewriting or repainting of existing writing shall be paid
for at half the rates.
(d) Add to rates in items 17041, to17043, 50 per cent, if painted
with fluorecent paints.

PER 10 Nos. (PER CM of height)


17041 Writing letters or figures (Block.
Roman, Italic or Indian) n exc. 30 cm

high

d 2 lseh- pkbZ ls de ds 'kCn 2 lseh- ekus tk;saxsA


[k 'kCn vkfn] xgjs jax ls iksrs tk;sxs rkfd og czq'k ds fpUg
jfgr xgjs vkSj l/ku fn[ks] ;fn vko';d gks rks mu ij rc
rd jksxu fd;k tk; tc rd fd ifj.kke izkIr u gks tk;A

x
?k

Rs.

17.20

fo|eku fy[kkbZ ij nqckjk fy[kkbZ ;k nqckjk jksxu djkbZ] dk


Hkqxrku vk/kh njksa ij gksxkA
ena 17041 ls 17043 dh njksa esa 50 izfr'kr tksM+sa ;fn
pednkj jxksa ls jaxkbZ dh x;h gksA
izfr 10 vad izfr lseh- mapkbZ
17041 'kCn ;k la[;k fy[kkbZ cM+]s jkseu] frjNs] Hkkjrh;
30lseh- ls vf/kd aps ugha

PER 10 NOS.

izfr 10 vad

17042 Index hands (natural size) or arrows

(upto 40cm long) as directed

17042 gkFk ds fpUg LoHkkfod vkdkj ;k rhj 40 lseh rd yEcs funsZ'kkuqlkj


17043 iw.kZ fojke] v/kZfojke] vYi js[kk;sa] izHksn] ;kstd]
dks"Vd vkfn

17043 Stops, commas, short lines, dashes,

hyphens, brackets, etc.

51.30
8.50

PER JOB

iz f r dk;Z

17044 Obliterating old writing of any


description, n exc 0.1 sq. m, with paint

to match existing work

17044 fdlh Hkh O;k[;k 0-1 oeh- ls vuf/kd dh iqjkuh


fy[kkbZ dks fo|eku jax ls feyrk gqvk jax djds
feVkuk

12.70

320

SECTION 17

SECTION 17PAINTING
[k.M 17&jksxu dk;Z
MISCELLANEOUS WORK
fefJr dk;Z
PER SQUARE METRE
17045 Removing old paint by paint removers
or burning off by blow lamps and
cleaning with scrapers, any number of

coats, any width or girth


17046 Preparing new zinc (or galvanised)
surfaces to receive painting, by coating
with mordant solution including

washing and cleaning, etc.


17047 Obscuring glass with one coat of oil

paint to imitate ground glass


17048 Sealing surfaces previously treated with
tar, bituminous composition, etc., with
one coat of knotting in preparation for

painting

izfr oxZ ehVj

Rs.

34.10

17045 fdruh Hkh ijr rFkk fdlh pkSM+kbZ ;k eksVkbZ ds


iqjkus jksxu dks jksxu gVk inkFkZ ;k ySEi ls
tykdj mrkjuk rFkk [kqjpuh ls lkQ djuk
17046 ubZ tLrh ;k jaxhu lrg dk jksxu djus ;ksX;
cukus ds fy, /kqykbZ o lQkbZ vkfn lfgr LFkkiu
ysi dh ,d rg yxkdj RkS;kj djuk

12.70
28.20

17047 rsyh; jksxu dh ,d rg yxkdj 'kh'ks dh i`"B


Hkwfe ij yxkdj 'kh'ks dks /kqa/kyk cukuk
17048 iwoZ esa ykj o dksyrkj feJ.k vkfn }kjk iksrh xbZ
jaxhu lrg ij jksxu dh rS;kjh ds fy, ,d rg
xk<s+ jksxu dh fcNkuk

12.30

PER 10 RUNNING METRES

izfr 10 ehVj

17049 Scaling external surfaces of soil pipes


etc. previously treated with tar or
bituminous composition with one coat

of knotting in preparation for painting


17050 Cutting in edges to line, to paint work of
different tints (last coat only), where not

otherwise provided for

17049 ey ufydk;ksa vkfn dh ckgjh jaxhu lrg] tks iwoZ


esa ykj o dksyrkj ds feJ.k ls iqrh ij jksxu dh
rS;kjh ds fy, ,d ijr xk<+s jksxu dh yxkukA
17050 fdukjksa dh lh/kh dVkbZ ds] fHkUu jax ds jksxu ij
vafre ijr dsoy jksxu djuk] tgka vU;Fkk fufnZ"V
u gksA

17.10

29.10

LINE PAINTING ON ROADS, ETC.


lM+d vkfn ij jksxu ls js[kk;sa [khpuk
(a) The rates include for provision of red signals to keep off
traffic from wet paint, cleaning road surface and working
during odd hours when traffic is light.
(b) For letters, etc. the linear measurements shall be taken
along the centre line of the painted width.
(c) 'The line painting shall stand out boldly and solidly
without showing signs of brush marks or surface
underneath. If necessary, the surface shall be repainted until
the desired result is obtained.
(d) The rates do not include for any priming coat, but include
for preparation of new or previously treated surfaces to
receive the painting.

d bu njksa esa xhys jksxu dks ;krk;kr ls cpkus ds fy;s yky


ladrs ksa dh O;oLFkk djuk] lM+d dh lrg dks lkQ djuk rFkk
,sls le; ij dke djuk tc ;krk;kr de gks] 'kkfey gSA
[k 'kCn vkfn ds fy, ijEijkxr eki jaxkbZ dh pkSM+kbZ esa e/;
js[kk ds lkFk&lkFk yh tk;sxhA
x js[kkvksa dh jaxkbZ xgjh vkSj l?ku gks ftlesa cz'q k ds fpUg rFkk
uhps dh lrg fn[kkbZ u nsA ;fn vko';d gks rks lrg ij
rc rd jksxu fd;k tk; tc rd fd bfPNr ifj.kke izkIr
u gks tk;sA
?k bu njksa esa dksbZ vLrjh ijr 'kkfey ugha gS fdUrq ubZ ;k iwoZ
mipkfjr lrg dks jax djus ;ksX; cukus dh rS;kjh 'kkfey
gSA

321

SECTION 17

SECTION 17PAINTING
[k.M 17&jksxu dk;Z
LINE PAINTING ON ROADS, ETC.Contd.

lM+d vkfn ij jksxu ls js[kk;sa [khapuk tkjh


PER SQUARE METRE
17051 Painting lines, dashes, arrows, letters, etc.
on roads, pavements and the like exc 10cm
wide with road marking paint, white or

golden yellow

Rs.

izfr oxZ ehVj

37.10

1705
170511 lM+d] iVjh o leku ij] lQsn ;k lqugjh ihys
lM+d Nki jax ls 10lseh- ls vf/kd dh js[kk;sa]
izHksn] rhj] 'kCn vkfn fy[kuk

PER 10 RUNNING METRES

izfr 10 ehVj

17052 Painting lines, dashes, arrows, letters, etc.


on roads pavements and the like n exc 10cm
wide with road marking paint, white or

golden yellow

1705
170522 lM+d] iVjh o leku ij] lQsn ;k lqugjh ihys
lM+d Nki jax ls 10 lseh- ls vuf/kd dh js[kk;sa]
izHksn] rhj] 'kCn vkfn fy[kuk

19.60

MATERIALS (SUPPLIED ONLY)

lkexzh dsoy vkiwfk


The paint and allied materials shall be supplied ready mixed in jax rFkk lEc) lkexzh iwoZ fefJr :i esa] mRiknd ds Meksa@ihiksa
makers drum/ kegs etc.
vkfn esa vkiwfkZ gksxhA
iz f r yhVj

Rs.

PER LITRE
17053 Creosote oil

42.30

1705
170533 yksgoku dk rsy

17054 Coaltar, crude for general purposes

28.10

1705
170544 dksyrkj dPpk] vke t:jrksa ds fy,

17055 Coaltar, black paint

28.10

1705
170555 dksyrkj dkyk] jax

PER LITRE

17056 Primers for wood and wood

based materials

Pink Zinc chrome Aluminium


primer
primer
primer

xqykch
vLrjh

ftad kse
vLrjh

vYeqfu;e
vLrjh

Rs.

Rs.

Rs.

79.90

103.40

91.70

iz f r yhVj

1705
170566 vLrjh jax] ydM+h rFkk ydM+h
vk/kkfjr lkexzh ds fy,

Aluminium Red oxide


Red
red oxide zinc chrome lead
primer
primer
primer

vYeqfu;e yky vklatd flanjq


yky vklatd ftad kse
vLrjh
vLrjh
vLrjh
17057 Primer for steel and iron

work

Rs.

Rs.

Rs.

71.70

86.90

83.40

1705
170577 vLrjh jax] bLikr rFkk yksgs ds
fy;s

322

SECTION 17

SECTION 17PAINTING
[k.M 17&jksxu dk;Z
MATERIALS (SUPPLIED ONLY)

lkexzh dsoy vkiwfk tkjh


Rs.

iz f r fyVj

17058 Priming paint, for brick, stone, concrete,


asbestos cement or plastered surfaces

87.60

17059 Red oxide paint for hessian

85.60

17058 vLrjh jax] bZaV iRFkj] dahV] ,LoSLVl lhesaV ;k


iyLrjh lrgksa ds fy,
17059 yky vkDlkbM] eksVs diM+s ds fy,

17060 Synthetic enamel paint (Ordinary tint)

17061 Plastic emulsion paint

150.40
191.50

17062 Aluminium paint (in dual containers)

144.50

17063 Black bituminous paint

17064 Synthetic enamel paint (Superior tint)

76.40

PER LITRE

108.10

17076 Varnish finishing, interior or exterior

114.00

17077 Lacquer, cellulose, clear or pigmented


17078 Mordant for use on zinc or galvanised

surfaces

17079 Stain oil, any tint

17080 Stain spirit, any tint

17081 Methylated spirit


17082 Paint remover, flammable or inflammable

470.00

17060
17061
17062
17063
17064
17065
17066
17067
17068
17069
17070
17071
17072
17073
17074
17075
17076
17077

86.90
63.40
55.20
25.80

17078
17079
17080
17081

82.20

17082 jksxu gVk izTofyr vnkgh ;k Toyu'khy nkgh]

169.20

17065 Exterior emulsion paint

17066 Thick white paint for lettering

17067 Acid resistant paint


17068 Fire resisting silicate paint

185.60

17069 Heat resisting paint

183.30

17070 Black Japan, any type

58.75

17071 Ready mixed paint for use on floors

130.40

17072 Knotting (Shellac varnish)

114.00

17073 Liquid filler, transparent, for wood

58.70

17074 Linseed oil, raw and refined

64.60

17075 French polish

169.20
168.03
185.60

flUFkSfVd ,usey jax


ik;l ,ey'ku jax
vYewfu;e jax nksgjs Mccs esa
dkyh jky fefJr jax
flUFkkSfVd ,usey jax
,DlVhfj;j ,ey'ku jax
xk<+k lQsn jax] 'kCnksa ds fy,
vEy vojks/kd jax
vfXu fu;a=d] vfZXu izLrj fefJr jax
rki fu;a=d jax

piV] tLrk ;k tLrh] lrg ij iz;ksx ds fy,


vfHkjatd rsy] fdlh Hkh jax esa
vfHkjatd fLifjV] fdlh Hkh jax esa
ouLifr fefJr ifjLd`r fLifjV

dkyk tkiku] fdlh fdLe dk


iwoZ fefJr jax] Q'kZ ds fy,
xk<+h piMs dh okjfu'k
rjy iwjd] ikjn'kZd] ydM+h ds fy,
vylh dk rsy] dPpk vkSj 'kq) fd;k gqvk
QSUp ikfy'k
okjfu'k ped Hkhrjh ;k ckgjh
lqugjh] dks'ke;] LoPN ;k jaxhu

iz f r fdyks x z k e

PER KILOGRAM
17083 Beeswax

152.70

17084 Grey filler for wood or steel/iron

37.60

17083 eD[kh ekse


17084 Hkwjk iwjd] ydM+h ;k bLikr@yksgs ds fy,

323

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
SECTION 18
WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES
[k.M 18&ty iwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
SPECIAL CONDITIONS
fo'ks"k 'krsZa
18-1 eki
d uy vkSj miLdkjksa dk O;kl] Hkhrjh fNnz dk ukHkh;
O;kl gksxk] tc rd fd vU;Fkk lacfa /kr Hkkjrh; ekud
esa vuqlwfpr u gksA
[k miLdkjksa ds vlaxr fNnz gksus dh n'kk esa] lcls cM+k
fNnz ukik tk;sxkA
(c) Pipes and fittings shall be measured net as
x uy vkSj miLdj] ml fufnZ"V ds vuqlkj ugha uisaxs]
specified for the respective type of the pipes.
tks fdlh fo'ks"k izdkj ds uy ds lac/a k esa fn;k x;k gksA

18.1 Measurements
(a) The diameter of pipes and fittings shall be the
nominal diameter of internal bore, unless
otherwise designated in the relevant Indian
Standard.
(b) In case fittings of unequal bore, the largest bore
shall be measured.

18.2 Rates
Rates for laying or fixing pipes and fittings etc.
include for:
(a) Distributing the pipes along the route of the
laying
(b) Any tackles or equipment required for lowering
the pipes, etc. in the trenches or for raising the
pipes, etc. to the required height.
(c) Testing of the system/installation (pipes,
fittings, manholes, etc.) as specified.
(d) For turning water off or on as necessary and
taking off and refixing covers, access doors etc.
18.3 Manholes:
All items of work in manholes shall be measured
under respective sections.

18-2 njs a
uyksa ;k miLdkjksa dks fcNkus ;k yxkus vkfn dh njksa esa fuEu
'kkfey gSA
d uy Mkyus ds jkLrs ij lkFk&lkFk uyksa dk forj.k
djukA
[k uyksa vkfn dks [kkb;ksa esa uhps mrkjus ds fy, ;k
bfPNr pkbZ rd mBkus ds fy;s] vko';d ;a= ;k
lk/ku tqVkukA
x i)fr@LFkkiuk uyksa] miLdkjksa] esugksyksa vkfn dh
visf{kr tkp djkukA
?k vko';drkuqlkj ikuh [kksyuk o can djus ds fy;s rFkk
<Ddu] igqp }kj vkfn dks gVkuk o iqu% yxkukA
18-3 es u gks y %
esugksy ds dk;Z dks lacaf/kr Hkkx dh njksa ds vUrxZr ekik
tk;sxkA

SUB-SECTION 'A' WATER SUPPLY


mi[k.M *,* ty vkiwfkZ
CAST IRON WATER MAINS
<ys yksgs ds ty iz.kky
(a) The measurement of pipes shall be net as fixed between the
fittings including short lengths, without any allowance
for cutting and waste, and in case of spigot and socketed
pipes for the portions entering the sockets of the pipes and
fittings. Fittings shall be measured separately. Excavation
and earthwork shall be measured separately.

d uyksa dh eki] NksVh yEckbZ;ksa lfgr] dVkbZ o Nhtu MkV o


dksVj yxs uyksa ds ml Hkkx ds tks bu miLdkjksa ds vUnj gS]a
dks NksMd
+ j LFkkfir :i esa fo'kq) yh tk;sx
a hA miLdj izFkd
ekis tk;saxsA Hkwfe [kqnkbZ o feh dk;Z izFkd eisaxsA

(b) The rates for laying pipes and fittings do not include for
jointing and jointing materials.

[k uyksa o miLdkjksa dks fcNkus dh njksa esa] la;kstu o la;kstu


lkexzh 'kkfey ugha gSA

324

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
CAST IRON WATER MAINS Contd...
<ys yksgs ds ty iz.kkyh tkjh
(c) The rates for laying cast iron water mains, etc. include
for laying level or to falls, in trenches, on the ground
or on supports above ground level.
(d) The rates in this table also apply to cast iron rising
mains in a sewerage system or similar work. The rates
do not include for clamps and other fixing accessories,
which shall be measured separately under Section
10Steel and Iron Work at 'Supplied and fixed' rates.
(e) No allowance shall be made for cuts on pipes in new
work or in repairs except when the pipes are supplied
by M.D. for 'laying only' in which case 'labour cutting
only' shall be allowed for each cut ordered and made.
(f) The rates for flanged pipes and fittings include cost
of C.I. screwed and drilled flanges and screwing tight
and flush with ends at right angle to the axis of pipe
including proper facing of flanges, where monolithic
cast flanged pipes are not manufactured.
PER RUNNING
METRE
SPIGOT AND
SOCKET
PIPES
18001 Cast iron pipes
with spigot and
socket ends
centrifugally
cast. Class LA,
in any length,
laid in trenches

18002 Ditto, class A,

ditto

x <ys yksgs ds ty iz.kky vkfn dh yxkus dh njksa esa uyksa dks


ry] xgjkbZ] [kkbZ;ksa esa] tehu ij ;k tehu ry ij lgkjksa
ij yxkuk 'kkfey gSA
?k bl rkfydk dh njsa] lhoj ;k vuq:i dk;Z esa mHkkjh iz.kkyksa
ij Hkh ykxw gksrh gSaA njksa esa f'kadtsa o vU; tqM+kbZ miLkk/ku
'kkfey ugha gS]a mUgsa [k.M 10& bLikr yksgk dk;Z ds **vkiwfkZ
o LFkkfir** dh njksa ds vUrxZr ekik tk;sxkA
M u;s dk;Z ;k lq/kkjksa esa uyksa dh dkV dh dksbZ NwV ugha nh
tk;sxh flok; tcfd uy ,e Mh us **dsoy fcNkbZ** gsrq fn;s
gksa] ml n'kk esa vknsf'kr o dkVs x;s izR;sd dkV ij **dsoy
dVkbZ Je** ekU; gksxk A
p dksjnkj uyksa ;k miLdkjksa dh njksa esa] <ys yksgs ds pwM+hnkj o
ojeh dksjksa okys rFkk tgka dksj;qDr uyksa dk fuekZ.k ugha gksrk
ogka dksjksa dh lgh x<r lfgr le dks.k ij ispksa ls dls
fdukjksa dh lgh x<+r okys uy 'kkfey gSaA

Materials and labour


lkexzh o Je
Bore in mm
fNnz feeh esa

iz f r ehVj

Except pipes
uy ds jfgr
Bore in mm
fNnz feeh esa

MkV o dksVj uy

80

100

150

200

250

300

80

100

150

200

250

300

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

18001 MkV o dksVj ;qDr


fdukjs <ys yksgs ds
uyds( dsUnz izlkfjr
<ys LA Js.kh ds
fdlh Hkh yEckbZ esa
[kkb;ksa esa Mkys x;s
902.30 1214.20 1748.30 2625.10 3443.40 4266.40 9.30 15.70 21.00 28.30 35.90 36.40

996.30 1331.80 1936.30 2848.30 3795.90 4712.90 9.30 15.70 21.00 28.30 35.90 36.40

18003 Ditto, class B,

ditto

1090.30 1508.00 2136.00 3130.30 4124.90 5088.90 9.30 15.70 21.00 28.30 35.90 36.40

18004 Cast iron pipes


with spigot and
socket ends,
vertically cast,
class A, in any
length, laid in

trenches

1125.50 1449.20 2077.30 3106.80 4089.60 4936.10 9.30 15.70 21.10 28.30 35.90 36.40

18002 lc en 18001 tSlk]


fdUrq A Js.kh
18003 lc en 18001 tSlk]
fdUrq Js.kh B
18004 MkV o dksVj fdukjs
okys uyds [kaMs <ys
*,* Js.kh ds fdlh Hkh
yEckbZ esa [kkb;ksa esa
fcNk;sa x;s

325

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
CAST IRON WATER MAINS Contd...
<ys yksgs ds ty iz.kkyh tkjh
PER RUNNING
METRE
SPIGOT AND
SOCKET PIPES
18005 Ditto, but class

B, ditto

Materials and labour


lkexzh o Je
Bore in mm
fNnz feeh esa

iz f r ehVj

Except pipes
uy ds jfgr
Bore in mm
fNnz feeh esa

80

100

150

200

250

300

80

100 150

200

250

300

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

1207.80 1578.50 2288.80 3247.80 4301.10 5241.60 9.30 15.7021.00 28.30 35.90 36.40

MkV o dksVj uyds


18005 lc en 2453 tSlk
fdUrq ch Js.kh

FLANGED PIPES

dks j ;q D r uyds

18006Cast iron pipes


with flanged
ends, centrifugally cast, class
A,
in any
length laid in
trenches
18007Ditto, but class

B, ditto

18006 dksj;qDr <ys yksgs


ds uyds dsUnzk;r
<ys] , Js.kh fdlh
Hkh yEckbZ es]a [kkb;ksa
esa fcNk;s x;s
1078.50 1508.00 2136.00 3294.80 4136.60 5206.40 9.30 15.7021.00 28.30 35.90 36.40

1219.50 1637.20 2476.80 3717.80 4876.90 5388.50 9.30 15.7021.00 28.30 35.90 36.40

18008Cast iron pipes


with flanged
ends/ verticaliy
cast, Class A, in
any length, laid

in trenches
18009All as in item
18008, but class
B, ditto

1160.80 1637.20 2335.80 3506.30 4301.10 5406.10 9.30 15.7021.00 28.30 35.90 36.40

1337.00 1801.70 2559.00 3823.60 5205.90 5782.10 9.30 15.7021.00 28.30 35.90 36.40

18007 lc en 2454 tSlk


fdUrq ch Js.kh
18008 <ys yksgs ds dksj;qDr
uyds [kM+h <ykbZ
, Js.kh fdlh Hkh
yEckbZ esa [kkb;ksa esa
fcNk;s x;s
18009 lHkh en 18008 tSlk
fdUrq ch Js.kh

CAST IRON FITTINGS FOR PRESSURE PIPE FOR WATER, GAS AND SEWAGE
yksgs dh <yh gqbZ miLdj nkolg uy ty xSl o ey ty ds fy,
uks V %
d bu njksa esa miLdkjksa dh <qykbZ] laHkky] rFkk e ls izLrkfor
dk;ZLFky ij j[kuk rFkk funs'Z kkuqlkj uyksa dh fcNkbZ ds lkFk
O;ofLFkr djuk 'kkfey gSA
(b) The rates also include for cutting of pipe for insertion of [k bu njksa esa miLdkjksa esa Mkyus ds fy,] tgka u;s dk;Z esa
fittings where necessitated in new works.
vko';drk gks] uy dh dVkbZ Hkh 'kkfey gSA
(c) The weight of fittings for the purpose of payment shall be x Hkqxrku ds fy,] miLdkjksa dk okLrfod Hkkj fy;k tk;sxk ;k
actual weight of fitting or weight as indicated for each
og Hkkj rks Hkk-ek- esa dksM Hkk-ek- 1538&1976 Hkkx 1 ls XXV
fitting in IS code IS-1538- 1976 (Part I to XXV).
esa fn;k x;k gSA
Notes:
(a) The rates include transportation, handling and placing in
position the fittings in proposed location and alignment
to the laying of pipes as ordered.

326

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
CAST IRON FITTINGS FOR PRESSURE PIPE FOR WATER, GAS AND SEWAGE Contd...
yksgs dh <yh gqbZ miLdj nkolg uy ty xSl o ey ty ds fy, tkjh
PER KILOGRAM

M&L

lkexzh ,oa Je
FITTINGS FOR SPIGOT
SOCKETED PIPES

18010Bends (any type, radius and


angle) tapers any type,
(straight, bend, increasing,
decreasing or double socket etc.)
Tee pieces single branch. "Y"
junction, double branch, cross
(all sockets or socket and spigot)

collars, caps and plugs

Labour only
except fittings

izfr fdyksxzke

dsoy Je
tqMu+ kj

MkVnkj dksVj ;qDr uy ds miLdj

Up to 150 200 to
Upto
200 to
bore in 300 mm 150 mm 300 mm
mm
bore
bore
bore

18010
18010eksM fdlh uewus] O;kl o dks.k
Qans fdlh uewus ds lh/ks] ewM]s+ c<ko
150 rd 200 ls 150feeh 200 ls
okys] ?kVko okys ;k nksgjs dksVj
feeh esa 300 feeh rd Nsn 300 feeh
okys] vkfn ,d 'kk[kk okyh Vh *Y*
Nsn
Nsn
Nsn
nksgjs 'kk[kk okys Y tksM+] pkSeqgkuh
Rs.
Rs.
Rs.
Rs.
lHkh dksVj ;k dksVj ;k MkV dkyj
Vksfi;ka rFkk Iyx
43.00

61.60

0.70

0.50

FITTINGS FOR FLANGED PIPES

MkVnkj dksVj ;qDr uy ds miLdj

18011Bends. Tapers. Tee pieces


(single & double branch) any
type and angle/radius and
straight connecting pieces but

all ends flanged


18012Connecting pieces one end
flanged and other socket or
spigot and bell mouth pieces
one end flanged other end

tapering as bell mouth

18011
18011eksM] Qans] Vh;ka ,dy ;k nksgjh
'kk[kk fdlh uewus vkSj dks.k@O;kl
rFkk lh/ks tksM+ okys [kaM fdUrq lHkh
ds fljs dksjnkj
18012
18012la;kstu [kaM ,d vksj dksjnkj nwljh
vksj dksVj ;k MkVnkj rFkk ,d vksj
dksjnkj nwljh vksj ladjs ?kaVh uqek
eqg okys

42.80

61.60

0.50

0.40

43.00

61.90

0.70

0.80

JOINTS FOR WATER MAINS


ty iz.kkyh tksM+
The rates for jointing flanged pipes and fittings include for
provision of bolts, nuts, washers and white lead or mineral oil.

dksjnkj uydksa o miLdkjksa dks tksM+us dh njksa esa] dkcyksa] f<ofj;ksa]


ok'kjksa o lQsnk ;k [kfut rsy dh O;oLFkk djuk 'kkfey gSA

327

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
JOINTS FOR WATER MAINS Contd...
ty iz.kkyh tksM+ tkjh
Materials and labour
lkexzh o Je
Bore in mm
fNnz feeh esa

EACH

iz R ;s d

Except pipes
uy ds jfgr
Bore in mm
fNnz feeh esa

SPIGOT AND
SOCKET PIPES
AND FITTINGS

80

100

150

200

250

300

80

100

150

200

250

300

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

18013 Cement joint

40.10

51.10

63.00

82.20

52.90

70.00

129.90 223.30 264.60 386.10 32.10 43.60 74.00 131.50 146.10 218.10

18014 Rubber gasket


joint
18015 Lead wool joint
18016 Run lead joint

105.80 135.30 30.10 34.70 44.00 55.50 74.10 92.60

135.70 174.70 275.80 365.30 500.70 613.60 52.50 79.30 107.10 148.10 186.40 238.00
265.80 342.80 510.30 740.90 908.50 1302.30 52.50 79.30 107.10 148.10 186.40 238.00

MkV o dksVj;qDr
uyds rFkk miLdj
18013 lhesaV tksM+
18014 jcM+ xkLdsV tksM+

18015 dkafpr ydM+h tksM+


18016 rjy lhlk tksM+k

FLANGED PIPES
AND FITTINGS

dksj;qDr uyds rFkk


miLdj

18017 Joint
with
rubber or fibre

board gasket

18017 jcM+ ;k js'ks Qyd


xkLdsV ls tksM+

46.70

67.30

102.90 152.30 196.40 283.80 32.10 43.60 74.00 131.50 146.10 218.10

CUTTING, TAKING UP, ETC. OF WATER MAINS


eq[; uy dh dVkbZ rFkk m[kkM+uk vkfn

d fuEufyf[kr rkfydk dh njksa esa lQkbZ djuk rFkk 200 eh- ls


vuf/kd LFkku ij j[kuk o visf{kr ty fuLdklu o fdukl
O;oLFkkA
(b) The length shall be measured net over all pipes and fittings, [k yEckbZ dh eki] uy o miLdkjksa dh dsUnz js[kk ds lkFk&lkFk
along the centre line of pipes and fittings.
ls uy o miLdjksa ds ij ls 'kq) dh tk;sxhA
(a) The rates in the following table include for cleaning and
removing n. exc 200 m and stacking, and also for turning
off water and draining the system as required.

328

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
CUTTING, TAKING UP, ETC. OF WATER MAINS Contd...
eq[; uy dh dVkbZ rFkk m[kkM+uk vkfn tkjh
PER RUNNING METRE

Bore of pipes in mm

18018Taking up cast iron water


mains (including all fittings), 80
with spigot and socket ends Rs.
and lead joints including
burning out joints and
20.90

recovering lead
18019Ditto, with flanged ends
including disconnecting

pipes and fittings complete


4.20

18020Ditto, asbestos cement


pressure pipes, any class,
(including all fittings),
including disconnecting
3.70
pipes and fittings complete
18021Deduct from item 18018, if
joints are of cement or

rubber gasket
12.50

uyksa esa fNnz feeh esa


100
Rs.

150
Rs.

41.80

57.10

200
Rs.

250
Rs.

300
Rs.

69.90 83.70 104.60

8.30

11.60

14.30 16.70 18.50

5.60

9.30

11.60 14.30 16.70

18023Ditto,
in position for
insertion of new tees,

branches, etc.
18024All as in item 18023 but
asbestos cement pressure
pipes in position ditto
18025Burning out lead joint in
position, including removing

old lead to store, etc.


18026Dismantling joints of flanged
pipes in position, including
removing old rubber or
fibre board gaskets, bolts,
nuts. etc. to store
18027Ditto, cast iron detachable
joints or asbestos cement
couplings
of
asbestos
cement pressure pipes in

position, including, ditto


18028Dismantling cement or
rubber gasket joints of
spigot and socket pipes
including removal of any
useful materials to store

24.40

33.20

40.60 48.90 61.10

68.10 103.20 115.70 138.90 185.20

55.50

69.40 111.10 138.90 166.70 222.20

27.80

37.00

40.50

18019 mi;qZDr] fdUrq dksjnkj fdukjs okys]


fcPNsnd uyksa o lHkh miLdkjksa lfgr]
liw.kZ
18020 mi;qZDr vng lhesaV ds nko lg
fdlh Js.kh ds uy] lHkh miLdjksa
lfgr] foPNsnd uy rFkk iw.kZ
miLdkjksa lfgr

18021 ?kVk;sa en 18018 ls ;fn tksM+ lhesVa ;k


jcM+ ds /kkxs ls yxs gksa

EACH
18022Cutting cast iron pipes and
reducing to required length
before laying (pipes supplied

by M.D. for laying only)


53.70

iz f r ehVj
18018 <ys yksgs ds MkV o dksVj fdukjs
okys] lhlk yxss ty iz.kkyksa dks lHkh
miLdkjksa lfgr tksM+ksa dks tykdj
lhlk fudkyus lfgr] fudkyuk

65.40

55.50

69.40 83.30 111.10

88.80 130.40 149.70 169.50

32.10

43.60

74.00 116.70 146.10 174.50

23.14

32.10

53.50

87.30 116.70 145.10

17.40

23.30

43.60

58.80 88.20 116.70

iz R ;s d
18022 yksgs ds nys] uyksa dks Mkyus ls igys
dkV dj misf{kr yEckbZ rd ?kVkuk
uy dh j{kk ea=ky; }kjk iwfrZ dsoy
fcNkus ds fy,
18023 mi;qZDr] ubZ Vh;ksa rFkk 'kk[kkvksa dks
yxkus dh fLFkfr esa ykuk

18024 lc en 18023 tSlk] ysfdu vng


lhesVa nkolg uy fLFkfr es]a mi;qDZ r

18025 fLFkr esa yxs tksM+ksa dks tykdj lhls


dks Hk.Mkj esa igqpkuk vkfn lfgrA

18026 yxs gq, dksjnkj uyksa ds tksM+ksa dks


[kksyuk] iqjkuh jcM+ ;k js'ks ds /kkxs]
dkoys o f<ofj;ka vkfn fudky dj
Hk.Mkj igqpkuk lfgr
18027 mi;qZDr] yksgs ds <ys fo;ksT; tksM+
;k vng lhessaV dh f<ofj;ka lfgr]
mi;qZDr

18028 MkV rFkk lkfdV okys uyksa ds lhesVa


;k jcM+ ds /kkxs ds tksM+ [kksyuk]
mi;ksxh lkexzh dks Hk.Mkj igqpkuk
lfgr

329

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
SLUICE VALVES, HYDRANTS, ETC. (SUPPLIED BY M.D.)
lywl okYo] cEcs vkfn j{kk ea=ky; }kjk iwfrZ
(a) The rates include for all jointing materials except rubber
or fibre board gaskets and bolts and nuts which shall be
supplied by M.D.
(b) The rates 'add if fixed in repairs' include for taking off
connecting pieces, bolts, nuts, jointing rings, etc, also
burning out run lead joints and removing retrieved articles
to store.
(c) Rates include for turning water off or on and draining the
system as required.
(d) Lead and cast iron detachable joints, connecting pieces,
adopters etc., where required, shall be measured separately.

SLUICE VALVES

d ;g njsa tksM+ yxkus dh lHkh lkexzh gSa flok; jcM+ ;k js'ks ds


/kkxs vkSj dkoys rFkk f<ofj;ksa ds ftudh iwfrZ j{kk ea=kky;
}kjk gksxhA
[k **tksM+as ;fn ejEer esa yxh gks** dh njksa esa tksM+ lkexzh dkcys
f<ofj;ka] tksM+ ufy;ka vkfn rFkk tykdj lhls ds tksM+ fudkyuk
vkSj iqjkuh phtksa dks Hk.Mkj esa igqp
a kuk Hkh 'kkfey gSA
x bu njksa esa ikuh myhpuk ;k ckgj fudkyuk rFkk misf{kr ikuh
fudklh dh O;oLFkk djuk 'kkfey gSA
?k yksgs ds <ys fo;ksT; rFkk lhlk tksM] la;kstd [kaM] xzkgh vkfn
tgka vko';d gks] vyx ls ukih tk;sxhA
lywl okYo

Bore of pipes in mm

uyksa esa fNnz feeh esa


EACH

80
Rs.

18029 Fixing only sluice valve with


33.70
flanged ends, any pattern
18030 Add if fixed in repairs 46.30

100
Rs.

150
Rs.

200
Rs.

250
Rs.

300
Rs.

55.50

92.60

96.60 102.50 138.90

18031 Repacking stuffing box of


sluice valve spindle
including taking apart and 60.20 92.60 115.70 157.40 199.10 231.50

reassembling
18032 Taking out sluice valves
refacing, regrinding and 231.50 347.20 462.96 601.80 740.70 787.00

refixing
FIRE HYDRANTS

18029

85.30 129.60 193.10 261.80 286.30

Fixing only

yxkuk dsoy
18033 Fire hydrants 65mm dia with
single flanged end, "pit" pattern,
including labour for jointing

only one flanged joint

59.80

18034 Pillar pattern fire hydrant, ditto

237.30

Rs.

18030
18031

18032 lywl okYoksa dks fudkydj iqu%


laokjuk] iqu% yxkukA
vfXu cEcs

Add if fixed in
repairs

tksM+sa] ;fn ejEer


18033 xM<suqek] 65 feeh O;kl ds ,d rjQ
esa yxs gksa
Rs.
ls dksjnkj fdukjs okys vfXu cEcs] ,d
29.80
dksjnkj fdukjs dks tksMu
+ s dk dsoy Je
18034 [kEHksuqek vfXu cEcs] mi;qZDr
138.90

SURFACE BOXES ETC.


18035 Stop valve (or sluice valve)
covers, cast iron, including
bedding in cement mortar 1:3.
complete
18036 Surface boxes, cast iron, for

fire hydrant, including ditto

iz R ;s d
fdlh Hkh rjhds ds dksjnkj fdukjs
okys lywl cYo dsoy yxkuk
tksMsa+] ;fn ejEer esa yxk;k gks
lywl okYo ds laos"Vd cDls dh
uko fudkydj [kksyuk] vyx djuk
rFkk iqu% tksM+us lfgr

18035
27.80

13.90

60.80

27.80

18036

lrgh cDls vkfn


yksgs ds <ys jksd ckYo ;k lywl ckYo
<Ddu] 1%3 lhesVas elkys esa yxkbZ lfgr
lai.w kZ
vfXu cEcs ds fy;s yksgs ds <ys lrgh
cDls mi;qZDr lfgr

330

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
WATER METERS (SUPPLIED BY M.D.)
ty ehVj j{kk ea=ky; }kjk iwfrZ
(a) The rates include for all jointing materials except rubber
or fibre board gaskets, bolts and nuts, which will be supplied
by M.D.
(b) New water meters for tubing upto 50mm diameter will be
supplied complete with union joints, new water meters for
tubing 80 to 150mm diameter will be supplied with flanged
ends, rubber or fibre board gaskets and bolts and nuts, also
with spigot and socket connecting pieces.
(c) Rates include for turning water off and on and draining
the system, as required.

[k uydksa ds fy, 50 feeh rd O;kl ds u;s ehVj ;qXey tksM+


lfgr]] 80 ls 150 feeh O;kl rd ds dksjnkj fdukjs lfgr
iwfjr fd;s tk;sx
a (s jcM+ ;k js'ks ds /kkxs rFkk dkoys o f<ofj;ka]
MkV o lkfdV rFkk tksMu+ s dh lkexzh dh Hkh iwfrZ dh tk;sxhA
x njsa] ikuh myhpus vkSj ckgj fudkyus rFkk funsZ'kkuqlkj ikuh
fudklh dh O;oLFkk djus lfgr gSA
ty ehVj fdlh uewus ds

Bore of pipes in mm

WATER METERS, ANY


PATTERN
EACH

d bu njksa esa tksM+ yxkus dh lkexzh 'kkfey gS flok; jcM+] js'ks ds


/kkxs vkSj dkoys o f<ofj;ka] ftldh iwfrZ j{kk ea=ky; }kjk gksxhA

cs/ku uy dk feeh esa


15
Rs.

28.80
18037Fixing only to steel tubing
18038Removing meter for testing,
etc., by unscrewing unions,
fitting unions with screw
plugs, or inserting short length
or tubing screwed both ends
so as to maintain supply 28.80
18039Replacing meter (old or new),
taking out plugs or temporary
connections and reconnecting
28.80

meter and unions


18040Removing meter (including
unions) screwed to steel

tubing
23.10

20
Rs.

25
Rs.

32
Rs.

40
Rs.

50
Rs.

28.80

28.80

28.80

29.90 58.70

28.80

34.90

40.50

46.50 58.70

28.80

34.90

40.50

46.60 58.70

iz R ;s d
18037
18037yksgs dh ufy;ksa dh dsoy LFkkiuk
18038
18038;qXeyksa ds isp fudky dj ehVj dks
tkap vkfn ds fy, fudkyuk] ;qXe dks
isp xV~Vksa ls yxkuk ;k vYi yEckbZ dh
uyh dks nksuksa vksj isp yxkdj cSBkuk
ftlls iwfrZ dk;e jgsA
18039
18039xV~Vs ;k vLFkkbZ lEca/k dks gVkdj
ehVj iqjkuk ;k u;k nqckjk yxkuk
rFkk ehVj ;qXeyksa dks iqu% tksM+uk
18040
18040yksgs dh uyh esa ispksa ls dls ehVj
;qXey lfgr gVkuk

23.10

23.10

23.10

23.10 46.30

Bore of pipes in mm

cs/ku uy dk feeh esa


80
100
18041Fixing only, including labour only for two
Rs.
Rs.
bolted flange joints; (run lead joints, if any,
shall be measured under item 18016) 156.70 205.60
18042Replacing meter with flanged joints;
including removal of flanged
connecting piece, or blank flange (if
required) or taking out meter for testing,
etc., and fixing (but not supplying) a
length of flanged connecting pipe (or
two blank flanges) and labour only

for two flanged joints


138.20 185.00

18043Taking out meter with spigot and


socket connecting pieces, including

burning out to lead joints

80.70

132.70

150
Rs.
333.20

296.20

177.60

18041
18041dsoy Je lfgr dsoy yxkuk] nks dkoys ds
dksjnkj tksMk+ as dks tksMu+ s ds fy, iryk lhlk tksM+
;fn dksbZ gks rks og en 18016 es ekih tk;sxh
18042
18042dksjnkj tksM+ ds lkFk ehVj ls iqu% yxkuk]
dksjnkj la;kstd [kaMksa ;k likV dksj dks
fudkyuk ;fn vko';d gks ;k ehVj dks tkap
vkfn ds fy, fudkyuk rFkk ,d yEckbZ ds
dksjnkj la;kstd uy ;k nks likV dksjnkj
yxkuk fdUrq iwfrZ ugha rFkk nks dksjnkj tksM+ksa
ds fy, dsoy Je
18043
18043MkV rFkk lkfdV la;kstd [kaMksa ds lkFk nksgjs
lhlk tksMksa lfgr ehVj fudkyuk

331

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
DRILLING AND TAPPING WATER MAINS
ty iz.kkyksa esa cjes }kjk Nsn djuk rFkk pwM+h dkVuk
(a) The rates include for turning water off and on and
draining and refilling the system as required.
(b) If water mains are to be drilled and tapped under pressure
(i.e. without turning off water flowing through them),
twice the following rates shall be paid.
EACH
18044 Drilling and tapping cast iron water mains
(in position) for branch connections of the

internal dia
18045 Ditto A.C. water mains (in position)
ditto including saddle piece and nuts and

bolts

d bu njksa esa ikuh dk tc rc cnyuk rFkk fudklh vkSj


vko';drkuqlkj iqu% ikuh Hkjus dh O;oLFkk djuk 'kkfey gSA
[k ;fn ty iz.kkyksa esa ikuh ds ncko ds le; Nsn djuk gS ;k pwM+h
dkVuh gS vFkkZr muesa pyrs ikuh dks fudkys fcuk rks fuEu njksa
ds nqxus ds cjkcj fn;k tk;sxkA

15 mm

20 mm

15 feeh

20 feeh

Rs.

Rs.

125.00

162.00

iz R ;s d
1 8 0 4 4 yksgs ds <ys iz.kkyksa esa Hkhrjh Nsn djuk rFkk pwMh+
dkVuk yxs gq, O;kl ds 'kk[kk feyku ds fy,
1 8 0 4 5 mi;qDZ r] mng lhesVa ty iz.kky fLFkfr esa mi;qDZ r
dkBh vkoj.kksa f<ofj;ksa vkSj dkoyksa lfgr

37.00

60.20

STEEL WATER TUBING


(a) The rates in the following table include for galvanised steel (Gl)
tubing with screwed socket joints, together with all tube fillings
(such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixing
complete with clips, wall hooks, wooden plugs, or laying in
trenches, etc., also for cutting, screwing and waste and for making
forged bends on piping as required. Connectors shall be inserted,
where required or directed. The rates also include cutting through
walls, floors, etc. and their making good.

(b) All measurements, whether 'laid complete', fixed complete' 'laying


only' or fixing only' shall be net. The rates for 'laying only', or
fixing only' include for labour, tools and plant and all tube fittings
and materials other than tubes & tube fittings.
(c) Isolated length of pipes under 1 m length (of all diameters) shall
be paid for as in 'Short lengths', 'Isolated' means not attached to
pipes of the same substance. A 15mm branch (under lm) of a
20mm steel tubing would not be 'isolated'.

[k

(d) Length of service or waste pipes where in connection with ranges


of lavatory basins, sinks, flushing cisterns, laboratory work
and the like requiring an exceptional number of fittings shall be
paid for as in 'Short lengths' and total enhanced by 20 percent.
The GE's decision regarding the portion of piping system to be
classed as in 'Short lengths or otherwise' shall be final and binding.

?k

(e) The rates do not include for cutting chases in walls, floors, etc.
and their making good in the case of concealed pipe work and
earth work in the case of pipes laid in trenches.
(f) If old tubes and tube fittings are supplied by M.D. and fixed by
the Contractor, an addition of 20 per cent shall be made to the
rate for 'laying only' or 'fixing only' to cover the cost of cleaning
or returning the old screw threads as required.

yks g s dh ty ufydk
fuEufyf[kr lwph dh njsa tLrh yksgs ds uyds] ispksa ls dls dksVj
tksM+ lHkh miLdkjksa tSls cSM
a ] dksgfu;ksa Vh;s]a NksVs mikax] la;kstd]
mYVs dkoys] U;qud mikax Vksfi;k o MkaV]s ;qXey vkfn lfgr gSa
rFkk] fpefV;ksa nhokj gqd] ydM+h dh MkVksa ls iw.kZr% fLFkj djuk
;k [kkbZ;ksa esa fcNkuk vkfn] dVkbZ] isp dlkbZ og Nhtu rFkk
visf{kr dksjnkj eksM+ uyksa esa cukuk HkhA tgka visf{kr gks ;k
funsfZ 'kr gks la;kstdksa dks ?kqlk;k tk;sxkA njksa esa nhokjksa Q'kksaZ vkfn
esa dVkbZ djuk rFkk mUgsa ifj"d`r djuk 'kkfey gSA
lHkh dk;Z pkgs og lai.w kZ fcNkbZ *lai.w kZ yxkbZ* o *dsoy fcNkbZ]
;k *dsoy yxkbZ*] ds gks 'kq) ekis tk;sx
a As bu esa Je] vkStkj] ;a=
rFkk lHkh uy miLdj o lkexzh vfrfjDr uy ds 'kkfey gSAa
,d ehVj ls de ds vdsys uy lHkh O;klksa ds dk Hkqxrku
*vYi yEckbZ* ds dk;Z leku gksxkA *vdsys* dk vFkZ gS fd og
leku fLFkfr ds uy ls tqM+s ugh gSaA 20 feeh yksgs ds uy dh
15 feeh dh ,d 'kk[kk 1 eh- ls de *vdsys* ugh gksxhA
lsok ;k ey uy dh yEckbZ tgka ;g /kko.k ik=] gkSfn;ksa] Lopky
Vadh] LoPNrk Vafd;ka rFkk leku] ls tqM+s gSaA vlkekU; la[;k
esa miLdj t:jh gks rks Hkqxrku *vYi yEckbZ* leku gksxk vkSj
;ksx esa 20 izfr'kr dh o`f) gksxhA uy ds fdl Hkkx dks *vYi
yEckbZ* vFkok vU;Fkk ekuk tk;s blds fy, nqxZ vfHk;Urk dk
fu.kZ; vafre ,oa ekU; gksxkA
nhokjksa] Q'kksZ vkfn esa f>jh fudkyuk ,oa HkjkbZ rFkk [kkb;ksa esa
nok;s x;s uy dk feh dk;Z 'kkfey ugh gSA

p ;fn iqjkus uy o miLdj ,e Mh us fn;s gSa vkSj Bsdsnkj us yxk;s


gSa rks *fcNkbZ dsoy* ;k *dsoy* yxkbZ dh njksa dk 20 izfr'kr
vf/kd Hkqxrku gksxk rkfd lQkbZ ;k iqjkus ispksa dh nqckjk Vwfuax
dh ykxr dh HkjikbZ gks ldsA

332

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
STEEL WATER TUBING Contd...
yksgs dh ty ufydk tkjh
PER RUNNING
METRE

uy dk Nsn feeh esa

18046 Tubes, 'light


15
20
25
32
grad',
Rs.
Rs.
Rs.
Rs.
galvanised,
with all fitting;
laid in trenches
103.90 133.50 203.10 265.30
18047 Tubes, 'medium
grade', ditto
108.60 142.90 214.90 285.30

18048 Laying only


tubes,
any
grade,
in
24.70 26.60
trenches
18049 Tubes, 'light
grade'
galvanised, with
all fitting and
fixed complete
to walls and
ceilings or laid

in floors
18050 Ditto, 'medium
grade', ditto
18051 Fixing
only
tubes,
any
grade, to walls
and
ceilings
or laying in

floors
18052 Add to the fore
going items, if
in
'short

lengths'

iz f r ehVj

Bore of tube in mm
40

50

80

100

150

Rs.

Rs.

Rs.

Rs.

Rs.

304.60

390.00 536.50 733.80

981.80

330.40

415.90 601.10 798.50 1046.50

18046 gYdh Js . kh ds
tLrk p<+s uyksa dks
lHkh miLdjks
lfgr [kkb;ksa esa
nckuk
18047 e/;e Js.kh ds uy]
mi;qZDr

18048 fdlh Hkh Js.kh ds


uyksa dks [kkb;ksa esa
dsoy nckuk

30.40

36.20

40.30

49.30

54.80

70.00

86.50

18049 gYdh Js . kh ds
tLrk p<+s uyksa dks
lHkh miLdkjks a
lfgr nhokjksa vkSj
Nrksa ;k Q'kkZas esa
yxkuk
111.90 144.40 215.80 279.20

322.30

411.60 566.10 763.50 1009.80

116.60 153.80 227.50 299.10

348.20

437.50 630.70 828.10 1074.40

33.20 37.50

39.20

50.00

57.90

70.90

84.40

99.60

114.90

25.50 25.50

36.60

36.60

48.60

69.40

85.60

99.50

120.40

18050 e/;e
mi;qZDr

Js . kh]

18051 fdlh Hkh Js.kh ds


uyksa dks] nhokjksa]
Nrksa ;k Q'kksaZ esa
dsoy yxkuk
18052 tksfM+;ksa ij dh
enksa esa ;fn *vYi
yEckbZ* esa gSa

333

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
STEEL WATER TUBING Contd...
yksgs dh ty ufydk tkjh
Pipe size in mm

PER RUNNING METRE


1216

1620

2025

2532

3240

(outside
(outside
(outside
(outside
18053 Supplying & laying in (outside
trencies Polyethylene dia-16mm) dia-20mm) dia-25mm) dia-32mm) dia-40mm)
(PE-AL-PE) compositc
Rs
Rs
Rs
Rs
Rs
pressure pipes includin
all Crimp type internal
sealing Plastic-Metal
Composite fittings (such
as elbows, tees, reducers,

etc.) complete
111.30
137.60
169.00
18054 Ditto but including
Compression
type
fittings in lied of crimp

type fittings.
245.70
308.10
18055 Laying only pipes in

trenches
12.00
14.80
16.90
17.10
20.80
18056 Supplying & fixing to
walls/chases/ceilings or
laying
in
floors
PolyethyleneAluminium Ployethylene
(PE-AL-PE) composite
pressure pipes including
all Crimp type internal
sealing Plansticmetal
Composite fittings (such
as elbows, tees, reducers,
couplers, short pieces,
connectors, etc.) and
hooks (in case of
concealed pipe work)/
clamps (in case of
exposed pipe work)
139.90
168.10
201.10

complete.
18057 - Ditto- but including
Compression fittings in
284.50
348.80
lieu of type fittings.
18058 Fixing only pipes to
walls/chases/ceilings

or laying in floors
19.50
21.80
25.50
30.10
35.70

REPAIRS, ALTERATIONS, ETC., TO WATER PIPES AND CONNECTIONS


ikuh ds uyksa vkSj l;kstuksa esa lq/kkj rFkk ifjorZu vkfn

d ;g njsa] lq/kkjksa rFkk ifjorZuksa esa] tehu ds ij ;k uhps yxs


uyksa ij ykxw gSa A
(b) 'The rates for taking down piping, etc., and removing to [k ;g njs]a uyksa vkfn dks fudkyus vkSj tgka t:jh gks miLdjksa
store include disconnection of fittings from tubing,
dks vyx djds] Hk.Mkj esa igqpkus lfgr gSA
(a) The rales apply to pipes above or below ground only in
repairs and alterations.

where required.
(c) The rates for 're-fixing only' include for cleaning or
rerunning the old screw threads as required.

x **nksckjk yxkuk dsoy** dh ;g njs]a lQkbZ djuk ;k vko';d


iqjkus isp narqvksa dks fudkyus lfgr gaSA

334

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
REPAIRS, ALTERATIONS, ETC., TO WATER PIPES AND CONNECTIONSContd...
ikuh ds uyksa vkSj la;kstuksa esa lq/kkj Rkk ifjorZu vkfn tkjh
Bore of pipes in mm

PER RUNNING METRE


18059 Taking up or down steel
tubing and connections,
including cleaning for refixing or removal to store
18060 Refixing old steel tubing and
connections in new or old
position (Walls, ceiling,

floors, etc.)

iz f r ehVj

uy dk Nsn feeh esa


15

20

25 or 32

40 or 50

Rs.

Rs.

Rs.

Rs.

8.80

10.60

14.30

19.00

38.30

44.00

54.00

73.90

CUTTING AND
SCREWING PIPES

18059 yksgs ds uyksa vksj la;kstuksa dks


fudkyuk ;k m[kkM+uk rFkk nksckjk
yxkus ds fy, lkQ djuk ;k Hk.Mkj
esa igqapkuk lfgr
18060 iqjkus yksgs ds uyksa vkSj la;kstuksa
dks ubZ ;k iqjkuh fLFkfr esa yxkuk
nhokjksa] Nrksa o Q'kkaZs vkfn
dVkbZ djuk rFkk isp dluk

Bore of pipes in mm

uy dk Nsn feeh esa

EACH
18061 Cutting existing steel
tubing for alterations or
additions
(Each
cut

measured)
18062 Screwing existing steel
tubing for alterations or
additions (or lengthening
screw on pipe to form
connector)
18063 Add to items 18061 & 18062
if necessarily done in position
without taking down

iz R ;s d

15

20

25 or 32

40 or 50

Rs.

Rs.

Rs.

Rs.

7.70

11.00

14.20

28.10

11.90

12.10

23.70

47.30

29.10

29.10

29.10

29.10

18061 fo|eku yksgs ds uyksa dks ifjorZu


;k ifjo/kZu ds fy, dkVuk izfr
dkV eisxh
18062 fo|eku yksgs ds uy ds isp dks
ifjorZu ;k ifjo/kZu ds fy, <hyk
djuk ;k uy ij la;kstd cukus
ds fy, isp c<+kuk
18063 en 18061 o 18062 esa tksfM+;s ;fn
fcuk fxjk;s fLFkfr esa ykusds fy;s
vko';d dk;Z fd;k x;k gksA

POLYETHYLENE AND UNPLASTICISED PVC PIPES

ikyhfFku rFkk vuIykfLVd`r ihohlh uyds


(a)

(b)

(c)

The rates in the following table include for pipes including


short lengths, with all pipe fittings such as ends, elbows,
unions, tees, reducing tees, adoptors, sockets, plugs, hose
clips etc. and fixing to walls etc, complete with saddles
(snap clips), wall clips, hooks, protective mild steel tube
sleeves and cutting through walls, floors and their making
good or laying in trenches and also cutting, screwing and
waste.
All measurements whether laid complete, fixed
complete, laying only or fixing only shall be net. The
rates for laying only or fixing only include for labour,
tools and plants and all tube fittings and materials other
than tubes.
The rates do not include for cutting chases in walls, etc.
and their making good in the case of concealed pipe work
and earthwork in the case of pipes laid in trenches.

d fuEu rkfydk dh njksa esa vYi yEcu lfgr uyksa miLdjksa


tSls dksjksa] dksfu;ka] ;qXeysa] Vh;k] U;wud Vh;ka] xzkfg;ka]
ldksVjsa] MkVsa] uyhnkj i+fr;ka vkfn vkSj nhokj vkfn esa
yxkuk] lai.w kZ dkBh lfgr dkVnkj ifk] nhokj [kwVh] dkaVs]
ueZ yksgs ds jf{kr nk;js rFkk nhokjksa Q'kksZa esa dVkbZ rFkk HkjkbZ
;k [kkb;ksa esa nckuk vkSj isp dlkbZ vkSj vof'k"V 'kkfey gSAa
[k lHkh ekis]a pkgs ^lai.w kZ fcNkbZ* ^lai.w kZ nckuk* ;k ^dsoy LFkkiu*
dh gksa fo'kq} gksx
a h] ^dsoy foNkuk* ;k ^dsoy LFkkiu* dh njksa
esa] Je] vkStkj o ;a= rFkk uyksa ds lHkh miLdj o lkexzh]
uy jfgr 'kkfey gSaA
x

nhokj vkfn esa f>jh fudkyuk o mudh HkjkbZ djuk ,oa


[kkbZ;ksa esa uyksa dks nckus ds ekeys esa ;g njsa ykxw ugha gksx
a hA

335

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
POLYETHYLENE AND UNPLASTICISED PVC PIPES Contd...
ikyhfFku rFkk vuIykfLVd`r ihohlh uyds tkjh
Bore of pipes in mm

PER RUNNING METRE

iz f r ehVj

uy dk Nsn feeh esa


18064 Low density poly
ethylene
pipes
(LDPE) of pressure
rating 6 kg/ cm2 laid

in trenches
18065 High density polyethylene
pipes
(HDPE) of pressure
rating 6 kgf/cm2 laid

in trenches
18066 Unplasticiscd PVC
pipes of pressure
rating 10 kgf/cm 2
laid in trenches
18067 Laying only pipes
any type and grade

in trenches
18068 Low density polyethylene pipes (LDPE)
of pressure rating 6
kgf/cm2
fixed
complete to walls,
ceilings or in floors

etc.
18069 High density polyethylene
pipes
(HDPE) of pressure
rating 6 kgf/cm 2
fixed complete to
walls, ceilings or in

floors etc.
18070 Unplasticised PVC
pipes of pressure
rating 10 kgf/cm 2
fixed complete to
walls, ceilings or in
floors etc., any type

of pipe
18071 Fixing only to walls,
ceilings or in floors
etc. any type of pipe

15

20

25

32

40

50

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

39.70

52.00

62.30

79.50

92.80

120.90

53.80

62.50

77.60

87.70

122.20

144.40

46.70

56.70

77.60

91.20

104.50

150.30

23.20

24.90

28.20

33.70

37.60

45.70

48.10

53.40

79.40

80.90

94.60

122.80

18064 fuEu ?kuRo ds ikyhfFku


uy fu/kiku nkc fu/kkZj.k
ds 6 fdxzkQ@lsa eh-2
[kkb;ksa esa nckuk
18065 mPp /kuRo okys ikyhfFku
uy m/kiku nkc fu/kkj.k
6 fdxzkQ@lsa- eh-2 dks
[kkb;ksa esa Mkyuk
18066 vuIykflVd`r ihohlh uy
nkc fu/kkZj.k 10 fdxzkQ@
ls-eh-2 [kkb;ksa esa Mkyuk
18067 fdlh uewus o fdlh Js.kh
ds uy [kkb;ksa esa dsoy
nckuk
18068 fuEu ?kuRo okys ikyhFkhu
uy fu/kiku nkc fu/kkZj.k
ij 6 fdxzkQ@lsea h-2 nhokjks]a
Nrksa ;k Q'kksZ vkfn esa yxkuk]
lai.w kZ
18069 mPp ?kuRo okys ikyhFkhu
m|iku ncko nj 6
fdxzkQ@ls-a eh-2 nhokjks]a Nrksa
;k Q'kksZa vkfn esa yxkuk
lai.w kZ

55.20

63.90

79.40

89.10

124.00

146.30

18070 vuikyhFkhu ihohlh uy


nkc fu/kkZj.k 10 fdxzkQ@lseh-2 fdlh Hkh uewus ds] nhokjksa
Nrksa ;k Q'kksZ vkfn esa yxkuk
lai.w kZ
57.20

24.60

58.10

26.30

79.40

30.10

92.60

35.00

106.40

39.40

152.10

47.60

18071 fdlh Hkh uewus ds uy


dsoy yxkuk] nhokjks]a Nrksa
;k Q'kks vkfn esa

336

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
POLYETHYLENE AND UNPLASTICISED PVC PIPES Contd...
ikyhfFku rFkk vuIykfLVd`r ihohlh uyds tkjh
Bore of pipes in mm

RUNNING METRE
15

18072 3-layer
PP-R Rs.
Polypropylene
random copolymer)
pipes SDR 7.4 &
SDR
11
UV
stablised
and
antimicrobial
welded
having
thermal stability for
hot & cold water
supply including
all PP-R plain &
brass
threaded
polypropylene
random fittings
fixed complete to
walls, ceilings or in
92.00
floors etc.

20

25

32

40

50

Rs.

Rs.

Rs.

Rs.

Rs.

1114.40

131.60

198.10

278.00

407.60

Bore of dia pipes in mm

RUNNING METRE

18073 3- layer PP-R


Polypropylene
random copolymer) pipes
SDR 7.4 & SDR
11 UV stablised
and
antimicrobial fusion
welded having
thermal stability
for hot & cold
water supply all
PP-R plain &
brass threaded
polypropylene
random fittings
laid in trenches.

16

20

25

32

40

50

63

75

90

110

160

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

81.20 101.50 133.50 186.90 263.80 480.80 815.00 1129.10 1816.10 1917.40 3992.90

337

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
POLYETHYLENE AND UNPLASTICISED PVC PIPES Contd...
ikyhfFku rFkk vuIykfLVd`r ihohlh uyds tkjh
EACH

Bore of pipes in mm

18074 Making connection of PP-R


distribution branch with PP-R main
of following sizes by providing and
fixing tee including cutting and

making fusion joint etc.

16 to 40

50 to 75

Rs.

Rs.

329.00

433.00

Bore of pipes in mm

EACH
20

25

32

40

50

63

75

18075 Fixing only water


Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
meter,
metal
stopcock gunmetal
gate valve, brass ball
valve, gunmetal
non-returning valve
in PP-R pipe line
(cost of male sockets
154.00 225.00 464.00 840.00 1716.00 2539.00 3232.00

included).
Bore of pipes in mm

EACH
20

18076 PP-R Gate valves


(brass insert) as per Rs.
requirement of the
390.00
site

25

32

40

50

63

Rs.

Rs.

Rs.

Rs.

Rs.

420.00

466.00

572.00

EACH
18077 PP-R Ball valves (brass
insert) as per requirement of

the site

862.00 1235.00

Bore of pipes in mm
20

25

32

40

Rs.

Rs.

Rs.

Rs.

710.00

762.00

1178.00

1239.00

338

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
WATER TANKS (SUPPLIED BY M.D.)

ikuh dh Vafd;k ,e Mh }kjk laiwfrZ

The rates for Hoisting and Fixing tanks include for removal
from store, hoisting into position either inside or outside
building, connecting up pipes, securing access covers etc., but
do not include for the provision of fixing of supports which
shall be measured separately.

Vafd;ksa dks ^mBkus vkSj yxkus* dh njksa esa Hk.Mkj ls ykus Hkou ds
vUnj ;k ckgj] mBkdj ;FkkLFkku yxkuk] uyksa dks tksMu+ k] vfHkxe
vkoj.k cukuk vkfn 'kkfey gS(a fdUrq lgkjs cukuk ugha tksfd izFkd
ekis tk;saxsA

Capacity in litres

EACH

iz R ;s d

lkeF;Z fyVj esa


N exc 250
Exc 250 Exc 500 Exc 1000
250 rd
& n exc 500 & n exc & n exc
250 ls
1000
2000
500 rd
500 ls
1000 ls
1000 rd 2000 rd

18078 Water tanks, open or closed,


hoisted and fixed in position

Rs.

Rs.

Rs.

Rs.

221.40

280.30

415.50

570.90

18079 Disconnecting existing


tanks, setting aside (or
lowering if required) for
repairs, cleaning, etc. and
hoisting
if
required
reconnecting and re-fixing in
position.
(Cleaning
repairing, etc. measured

separately)

22140

280.30

415.50

570.90

18080 Dismantling water tanks and

removing to store

178.40

225.70

329.50

428.70

18081 Cleaning and removing all


scale and dirt, etc, from tanks
and from mouths of

circulating pipes, etc.

115.70

173.60

232.00

287.00

18078 ikuh dh Vadh] [kqyh ;k cUn]


mBkdj ;FkkLFkku yxkuk
18079 fo|eku Vafd;ksa dks uyksa ls izFkd
djds] ,d vksj j[kuk ;k ;fn
vko';d gks rks uhps mrkjuk
ejEer lQkbZ vkfn ds fy,]
vkSj ;fn vko';d gks rks mBkuk
nksckjk uyksa dks tksM+uk vkSj
;FkkLFkku yxkuk] lQkbZ] ejEer
vkfn izFkd ekih tk;saxh
18080 ikuh dh Vafd;ksa dks m[kkM+uk
vkSj Hk.Mkj esa igqapkuk
18081 lHkh iiM+h] /kwy vkfn Vadh rFkk
izlkj.k uyksa ds eqgkuksa vkfn ls
lkQ djuk vkfn

339

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
PVC WATER TANKS

ihohlh ikuh Vafd;ka


The rates for Hoisting and Fixing tanks include for hoisting
into position either inside or outside of building, connecting up
pipes, securing access covers etc., but do not include for the
provision of fixing of supports which shall be measured
separately.

Vafd;ksa dks ^mBkus vkSj yxkus* dh njksa esa Hkou ds vUnj ;k ckgj]
mBkdj ;FkkLFkku yxkuk] uyksa dks tksM+uk vfHkxe vkoj.k cukuk
vkfn 'kkfey gSa( fdUrq lgkjs cukuk ugha tksfd izFkd ekis tk;saxsA

Capacity in litres

EACH

iz R ;s d

lkeF;Z fyVj esa


250

500

750

1000

2000

Rs.

Rs.

Rs.

Rs.

Rs.

18082 Rotational moulded polyethylene water storage


tanks (cylindrical vertical
with closed top) hoisted
and fixed in position all as

specified in SSR Part I

1113.40 2149.50

3144.60 4401.90 8454.30

18083 Ditto, except water tank

114.70

158.60 158.60

117.30

218.70

18082 vkorZd xfBr ikyhFkhuh Vafd;ka


xksykdkj [kM+h] can 'kh"kZ ,l
,l vkj I es fufnZ"Vkuqlkj
mBkdj LoLFkku esa LFkkfir

18083 mi;qZDr] ikuh Vadh jfgr

LAGGING AND WRAPPING ON PIPES WITH BONDED MINERAL WOOL


PRE-FORMED PIPE SECTIONS

iwoZ cus uy [kaMksa dks [kfut +u ls yisVuk o <duk


(a)

(b)
(c)

(d)

The rates for Materials and Labour include for all


insulating material, reinforcement, binding, wrapping,
etc. necessary for the proper execution of the work.
The rates for lagging and wrapping pipes include for
lagging or wrapping all bends etc.

d lkexzh ,oa Je dh njsa] dk;Z ds leqfpr lHkh fuoZgu esa


vko';d HkjkbZ lkexzh] izoyu ca/kkbZ] <dkbZ vkfn] lfgr gSAa

[k yisVus o <dus dh njksa esa lHkh eksM+ vkfn dh fyiVkbZ <dkbZ


'kkfey gSaA
No deduction shall be made for opening to which lagging x ftu eks[kksa dh <dkbZ ugha gqbZ gS mudh dkVkSrh ugha gksxh vkSj
is not applied and no extra shall be allowed for finishing,
uk gh vfrfjDr Lohdkj gksxk bu eks[kksa ds pkjksa vkSj dh
lagging around such openings.
ifj"d`fr ijA
?k
;g njsa vUnj dh vksj iz;qDr uyksa ij ykxw gSa [kqys uyksa ij
These rates are applicable for pipes used internally not
exposed to weather.
ughaA

340

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty vkiwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
LAGGING AND WRAPPING ON PIPES WITH BONDED MINERAL WOOL
PRE-FORMED PIPE SECTIONSContd...

iwoZ cus uy [kaMksa dks [kfut +u ls yisVuk o <duk tkjh izfr ehVj
On pipe of internal dia (in mm)

PER RUNNING METRE

iz f r ehVj

Hkhrjh O;kl ds uy ij feeh esa

18084 Lagging to pipes used in


internal water supply or
plumbing all round with,
25min thick bonded mineral
wool preformed SNAP ON
pipe sections of density 144
Kg/cum conforming to IS

9842

61.80

68.90 73.60 75.90

18085 dobut with 40mm thick

sections anddo

88.80

95.10 103.50 109.80 116.00 124.00

15

20

25

32

40

50

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

80.60

88.80

18086 dobut with 50 mm thick

sections
18087 Extra over serial Items 18084
to 2600 if provided with
chicken mesh wire netting 25

gauge, 20mm mesh


18088 Ditto, with 0.01mm

aluminium foil

12.40

13.40 14.50 15.90

16.90

53.40

55.00 56.80 60.00

60.80

18084 Hkhrjh ty iwfrZ esa iz;qDr ;k


pkjksa vksj ls 25 feeh eksVs [kfut
iwoZ cus u ds xqPNksa ls ^Lusiu*
144 fdxzk-@?ku eh- ?kuRo okys
Hkk-ek- 9842 vuqlkj] uyksa dks
yisVuk
18085 +ij tSlk fdUrq 40 feeh eksVs
vkSj ij tSlk

18086 +ij tSlk fdUrq 50 feeh eksVs


Hkkx vkSj +ij tSlk
18087 vfrfjDr] en 2598 ls 2600
;fn iwfrZ 25 feeh >hyh rkj]
20 feeh tkyh ds lkFk gks
18.90
18088 mi;qZDr 0-01 feeh vYeqfu;e
64.10
odZ ds lkFk

SUB-SECTION BPLUMBING

miHkkx ch&uy yxkus dk dk;Z


PLUMBING GENERALLY

uy dk;Z lkekU;r;k
(a)

The rates for articles described as 'fixed' include for


making all necessary joints. The rates for add if fixed in
repairs include for taking off the old fittings (including
sweating off soldered joints where required), closing
the opening with plug or preparing for new as required,
and removing old fittings to store.

(b)

If stop valves are to be fitted with strong square- ended


spindles to suit turn-cocks key, the same rates as for crutch
handles shall be allowed. If full way valves are fitted
with unions to lead pipes, the corresponding extra rates
for stop valves so fitted and fixed shall be allowed

d ^yxh gqbZ* dgs tkus okyh oLrqvksa dh njsa lHkh vko';d tksM+
cukus lfgr gSAa ^tksfM;s ;fn ejEer esa LFkkfir njksa esa 'kkfey
gS]a iqjkus miLdjksa dks fudkyuk Vkadh yxs tksMk+ as dks [kksyuk
tgka vko';d gks lfgr MkV ls [kqys LFkku dks can djuk ;k
vko';drkuqlkj u;s ds fy, rS;kj djuk vkSj iqjkus miLdjksa
dks Hk.Mkj esa igaqpkukA
[k ;fn jksd okYo dks] fQjdh VkSaVh pkHkh ds mi;qDr cukus ds
fy;s] nz< pkSdksj fdukjs okyh /kqjh ds lkFk yxkuk gS rks ?kqekoh
ewBksa dh njs]a Lohd`r gksx
a hA ;fn iw.kZiFk okYo yxk;s gSa ;qXey
ds lkFk lhls ds uy esa] rks caUn okYo fcBkuk vkSj yxkus dh
lekukUrj njsa Lohd`r dh tk;saxhA

341

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
PLUMBING GENERALLYContd...
uy dk;Z lkekU;r;% tkjh
TAPS, VALVES, ETC.
EACH

Bore dia of pipe in mm


uy dk fNnz O;kl feeh esa

Fixing
Add if
only any fixed in
bore dia repairs

dsoy
LFkkiu
dksbZ
O;kl

TAPS

18089 Plug type bib taps,


15
20
25
cast iron, screwed
Rs.
Rs.
Rs.
for iron pipe and
50.10 56.20 62.10
fixed
18090 Self closing taps of
cast
iron
or
malleable cast iron,
galvanised, screwed
for iron pipe and
61.80 76.10 96.10
fixed
18091 Concussive push
button taps of cast
copper
alloy,
screwed for iron
pipe and fixed 120.60 203.00 235.40
18092 Ditto, but of cast iron 50.10 80.90 103.30
18093 Bib taps, cast
copper alloy with
crutch or butterfly
handle, screwed
down, screwed for
iron pipe or for
brass ferrule and
103.00 150.20 173.70
fixed
18094 Ditto, but fancy type
162.70 221.60 256.90
18095 Add to item 18093 if
chromium plated
23.20 23.50 31.20
18096 Add to item 18094 if
17.60 25.80 35.20
chromium plated

VksafV;ka] okYc vkfn


iz R ;s d

tksM+sa ;fn
ejEer
esa

32

40

Rs.

Rs.

Rs.

Rs.

64.50

68.10

15.00

7.40

Vks a f V;ka

18089 <ys yksgs ds Iyx fdLe


ds eqM+h VksaVh dks isapksa ls
yksgs ds uyksa esa yxkuk

18090 Lo;a can gksus okys <ys


yksgs ds ;k <yoka yksgs ds]
tLrh isp yxkdj LFkkfir

104.50 116.30

15.00

7.40

263.10 320.80

15.00

7.40

109.20 121.00

15.00

7.40

193.80 220.90

15.00

7.40

298.10 345.20
64.60

70.50

52.90

64.60

16.00

8.80

18091 rkaos fefJr /kkrq ds <ys]


>Vdsnkj nkc cVu Vksfa V;ka
yksgs ds uyksa esa ispksa ls
LFkkfir
18092 mi;qDZ r] fdUrq <ys yksgs ds
18093 rkEcs /kkrq fefJr pdjh
;k frryh ew<+ okys mrkj
isp yksgs ds uy ;k ihry
dh lkeh esa isp dl dj
vkSj fLFkj djuk

18094 mi;qZDr] fdUrq vuks[ks


uewus ds
18095 tksM+sa en 18093 esa ;fn
ksfe;e ijrnkj
18096 tksM+sa en 18094 esa ;fn
ksfe;e ijrnkj

342

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
PLUMBING GENERALLYContd...
uy dk;Z lkekU;r;% tkjh
TAPS, VALVES, ETC.
EACH

Bore dia of pipe in mm


uy dk fNnz O;kl feeh esa

TAPS
18097 Pillar taps, cast
copper alloy, with
capstan
heads,
chromium plated,
15
20
25
32
40
screwed down high
Rs.
Rs.
Rs.
Rs.
Rs.
pressure, with or
without lettered
'Hot' or 'Cold' with
long
screwed
shanks and fly-nuts,
screwed for iron
pipe and fixed 214.40 238.00 290.90 308.60 320.30

Fixing
Add if
only any fixed in
bore dia repairs

dsoy
LFkkiu
dksbZ
O;kl
Rs.

14.70

13.90

15.70

14.80

15.00

7.40

23.10

iz R ;s d

tksM+sa ;fn
Vks a f V;ka
ejEer
18097 [kEHks dh Vksfa V;ka] rkaos fefJr
esa
/kkrq ds <ys pj[kh 'kh"kZ
ksfe;e ijr p<+s mPp
nkc mrkj isp] ^xeZ* ;k
Rs.
^BaMk* 'kCn fy[ks gq;s ;k
fcuk fy[ks pwM+hnkj MaMh
rFkk p+d f<ojh] yksgs ds
uy esa isapksa ls LFkkfir

18098 Ditto, but fancy type


279.90 321.20 338.80 350.60 356.60
18099 Self-closing taps,
cast copper alloy,
chro-mium plated,
screwed for iron
pipe and fixed 197.00 214.80 238.20 267.80 285.50
18100 Brass CP mixer for
mixing hot & cold
water
screwed
down for iron pipe
963.10
and fixed

VksafV;ka] okYc vkfn

18.50

18098 mi;qZDr] fdUrq vuks[ks


uewus ds
18099 Lo;a can gksus okyh Vksfa V;ksa
rkaos fefJr /kkrq ds <ys]
ksfe;e ijr p<s+( yksgs
ds uyksa esa ispksa ls LFkkfir
18100 ksfe;e ijr p<k ihry
dk feDlj B.Mk o xeZ
ikuh feykus ds fy, yksgs
ds uyks es ispksa ls LFkkfir

343

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
PLUMBING GENERALLYContd...
uy dk;Z lkekU;r;% tkjh
TAPS, VALVES, ETC.Contd...
EACH
STOP/GATE
VALVES
18101 Stop valves, cast
copper
alloy,
screwed down,
high
pressure,
with crutch or
butterfly handle,
screwed both
ends for iron
pipe or
for
unions and fixed

18102 Ditto but fancy


type, chromium

plated

Supplied and fixed


vkiwfkZ rFkk LFkkfir

Fixing only
dsoy LFkkiu

Add if fixed in
repairs

Bore dia of pipe in mm


uy dk fNnz O;kl feeh esa

Bore dia of
pipe in mm
uy dk fNnz
O;kl feeh esa

Bore dia of
pipe in mm
uy dk fNnz O;kl
O;kl feeh esa

15

20

25

32

40

50

15&
20

25&
32

40&
50

15& 25& 40&


20
32
50

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

150.30 215.00 301.00 383.20 412.20 476.80

Rs.

Rs.

26.40 30.70 36.20 13.40 15.40 18.10

iz R ;s d
jks d @dikV okYo
1 8 1 0 1 jksd okYo] rkack feJ
/kkrq ds] mrjh] mPp
nkc o pdjh ;k
frryh ewB okys] yksgs
ds uyksa ;k mEedksa esa
nksuksa vksj ls ispksa ls
LFkkfir

1 8 1 0 2 mi;Z D r]
fdUrq
ksfe;e] ijr] vuks[ks
uewus ds
169.00 241.80 334.90 396.00 507.20 595.30

18103 Ditto, but fancy


type, chromium
plated with long
shank and cup
(concealed type)

18104 Gun-metal, globe


or gate valves,
with iron wheel
head, screwed
both ends for iron
pipe and fixed

VksafV;ka] okYc vkfn tkjh

28.00 31.40 37.20 14.30 16.30 19.00

1 8 1 0 3 mi;qDZ r] fdUrq vuks[ks


fdLe] ksfe;e ijr]
yEch MaMh o p"kd
xqIr iz:ih
271.00 344.50 416.60 517.50 585.00 718.90

206.10 252.20 413.80 471.40 568.50 893.10

29.00 32.80 38.30 15.30 17.20 20.00

27.00 30.70 36.20 13.40 15.40 17.80

1 8 1 0 4 yksgs ds ph+ 'kh"kZ okys


izdkaL;] xksyd ;k
dikV okYo] yksgs ds
uy esa nksuksa vksj ispksa
lsa LFkkfir

BALL VALVES

xks y okYo
iz R ;s d

EACH
18105 Ball brass valves,
high pressure,
with polythene
float and flynut
complete,
screwed for iron
pipe or brass
ferrule and fixed

1 8 1 0 5 Hkkjh nkc] xksy okYo]


ikyhFkhu Iyc o p
f<cjh ds lkFk] yksgs
ds uy ;k ihry dh
lkeh esa isp dl dj
LFkkfir
167.20 293.70 320.30 469.00 763.30 1245.30

24.70 29.90 31.40 11.60 13.90 18.50

344

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
PLUMBING GENERALLYContd...
uy dk;Z lkekU;r;% tkjh
VksafV;ka] okYc vkfn tkjh

TAPS, VALVES, ETC.Contd...


FERRULES

Bore Diameter of pipe in mm

EACH

uy dk fNnz O;kl feeh esa

18106 Straight
plain
brass
ferrules (or connecting
screws) screwed both

ends and fixed


18107 Elbows; brass both ends

screwed and fixed

15
Rs.

20
Rs.

25
Rs.

32
Rs.

40
Rs.

50
Rs.

308.70 449.90 554.50 777.30 1166.60 1733.80

137.00 186.20 239.90 293.20 385.90 531.30

UNIONS
18108 Unions. brass to connect
iron to polyethylene and

fixed

101.90 146.90 188.40 241.80 305.10 385.50

18109 Add to items 18100 to18108


if fixed in repairs where the

taking off includes


18110 One end screwed to iron

pipe, etc.
18111 Both ends screwed to iron
pipes, or one flange end
bedded in red lead cement,
and other end screwed to

iron pipe, etc.

11.60

11.60

13.90

13.90

23.00

34.70

12.80

13.40

16.00

16.00

25.10

34.40

PERFORATED CAPS

Bore diameter of pipe in mm

uy dk fNnz O;kl feeh esa


18112 PVC perforated caps screwed to
ends of puff or vent pipes

15

20

25

32

Rs.

Rs.

Rs.

Rs.

13.90

14.50

20.50

21.30

QS:y tksM+ pwM+h&lkeh


iz R ;s d
18106 lh/ks lkns ihry ds QS:y ;k
la;kstu isp nksukas vksj ls ispksa ls
dls o LFkkfir
18107 nksuksa vksj ls ihry dh dekfu;k]
ispksa ls dlh o LFkkfir
;q X ed
18108 ihry dh ;qXed] yksgs ds uy
dks ikyhFkhu uy ls tqMh+ o LFkkfir

18109 tksM+sa en 18100 ls 18108 esa]


;fn ejEer esa tgka m[kkM+uk Hkh
'kkfey gS] LFkkfir
18110 ,d fdukjk yksgs ds uy vkfn esa
ispksa ls dlk
18111 nksuksa fdukjs ispksa ls dls ;k ,d
fdukjk lhlk lhesaV ls nck rFkk
nwljk fdukjk ispksa ls yksgs ds uy
ls tqM+k
fNfnzr Vksfi;ka

18112 ihohlh fNfnzr Vksfi;ka lkbQu ;k


lackrh uy ds fdukjksa ls isp ls
dlh

345

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
PLUMBING GENERALLYContd...
uy dk;Z lkekU;r;% tkjh
TAPS, VALVES, ETC.Contd...
PLUGS (WASTE) WITH
RINGS

Materials & labour

Fixing
only

lkexzh ,oa Je

dsoy

EACH

18113 Rubber or vulcanite plugs


(waste) with rings and

fitting and fixing


18114 Ditto, but including chromium
plated brass or bronze
chain and stay (chain n exc

50 cm in length)
18115 Waste fittings, brass,
chromium plated for glazed
ware sinks, basins, etc.
with long screwed shanks
and fly-nuts, flange end
bedded in red lead cement

and other end fixed

VksafV;ka] okYc vkfn tkjh


xs vif'k"V tathj ds lkFk

Add if
fixed in
repairs

LFkkiu

tksM+s ;fn
ejEer esa

32mm 40mm 50mm


Rs.

Rs.

Rs.

Rs.

Rs.

23.50

32.60

40.40

9.30

4.60

41.20

52.80

63.20

13.90

6.90

60.10

76.60

84.40

14.00

6.90

iz R ;s d
18113 jcM+ ;k xU/kd ;qDr jcM+ ds xs
vif'k"V tathj o miLdj rFkk
LFkkfir
18114 mi;qDZ r] fdUrq ksfe;e ihry ;k
rkacs dh tathj o Vsd Tathj yECkkbZ
esa 50 lseh vuf/kd lfgr
18115 vif'k"V miLdj] ihry ksfe;e
;qDr ihry ds vif'k"V miLdj
dkafpr gkSnh] /kou ik= vkfn gsrq
yEcs pqMhnkj MaMh o pO; f<ojh
ds lkFk] dksjnkj fdukjk yky lhlk
ls nck o nwljk fLFkj

POLYTETRA METHYLENE TEREPHTHALATE


(PTMT) ENGINEERING THERMOPLASTIC BATH FITTING
PIMT fittings shall be of approved makes
EACH
18116 Push tap any colour
high pressure of PTMT
screwed for iron pipe
and fixed, (Minimum
weight 15mm-47gms/

20mm- 75gms)
18117 Ditto but with nipple.
.(Minimum weight

20mm- 110gms)
18118 All as per 18116 but
suitable for urinals,
(Minimum weight

15mm-50gms)
18119 Bib tap standard of
PTMT any colour high
pressure screwed for
iron pipe and fixed.
(Minimum weight
15mm-90gms/20mm
125gms).

S & F vkiwfrZ rFkk LFkkfir


Bore dia of pipe in mm
uy dk fNnz O;kl fe-eh- esa

Fixing
only
dsoy

Add if
fixed in
repairs

15mm 20mm 25mm 40mm

LFkkiu

Rs.
76.20

Rs.
13.90

tksMsa+ ;fn
ejEer esa
Rs.
7.40

Rs.
91.80

Rs.

Rs.

18116

18117
113.20

13.90

7.40

18118
91.80

13.90

7.40

101.20 154.10

13.90

7.40

18119

iz R ;s d
nckus okyh Vksfa V;ksa fdlh Hkh
jax dh mPp nkc ihVh ,e
Vh] yksgs ds uy es ispksa ls
lhfir U;wure otu 15 feeh47 xzke@20 feeh- 75 xzke
mi;qDZ r fdUrq fuIiy ds lkFk
U;wure otu 20 feeh- 110
xzke
lc en 18116 tSlk fdUrq
ew=ik= ds fy, mi;qDr]
U;wure otu 15feeh- 50xzke
mrkj isp VksVa h;ks fdlh Hkh
jax dh mPp nkc ihVh ,e
Vh] yksgs ds uy es ispksa ls
LFkkfir* U;w u re otu
15feeh- 90xzke@20feeh125xzke

346

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
Table (Contd)....
EACH
18120

18121

18122

All as per item 18119 but


fancy type, (Minimum

weight 15mm-105gms)
All as per item 18119 but
with long body.
(Minimum weight

15mm-120gms)
All as per item 18119 but
with nozzle, (Minimum
weight 15mm-95gms)

iz R ;s d

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

122.90

13.90

7.40

143.70

13.90

7.40

18120 lc en 18119 tSlk fdUrq


vuks[ks uewus ds U;wure otu
15 feeh- 105 xzke
18121 lc en 18119 tSlk fdUrq
yEch ckMh dh U;wure otu
15feeh- 120xzke

112.60

13.90

7.40

144.60

14.80

7.40

181.00

14.80

7.40

110.40 124.90

23.10 11.60

172.30 181.30

25.50 13.00

18123

Pillar taps of PTMT any


colour high pressure
screwed for iron pipe
and fixed.(Minimum

weight 15mm-110gms)
18124 Ditto but fancy type.
(Minimum weight

15mm-120gms)
18125 Stop valve of PTMT
any colour high
pressure screwed for
iron pipe and fixed.
(Minimum weight
15mm-90gms/ 20mm92gms)
18126 Ditto but with long
shank and
cup
(concealed
type),
(Minimum weight
15mm-110gms/20mm112 gms)
18127 Angle stop valve of
PTMT any colour
high pressure screwed
for iron pipe and fixed,
(Minimum weight

15mm-90gms)

132.20

18122 lc en 18119 tSlk fdUrq


uksty ds lkFk U;wure otu
15feeh- 95xzke
18123 [kEHks dh VksVh;ks]a ihVh ,e Vh]
fdlh jax dh] mPp nkc] yksgs
ds uyks es ispks esa LFkkfir
U;wure otu 15feeh- 110xzke
18124 mi;qZDr fdUrq vuks[ks uewus
ds U;wure otu 15feeh 120 xzke
18125 jksd okYo] ihVh,eVh] fdlh
jax dh] mPp nkc yksgs ds
uyks es ispks ls LFkkfir
U;w u re otu 15feeh 90xzke@20feeh- 92xzke
18126 mi;qDZ r yEcs lSud vksj di
ds lkFk] xqIr izdkj U;wure
otu
15feeh110xzke@20feeh- 112xzke

18127 dks.kh; jksd okYo ihVh] ,e


Vh fdlh jax dh mPp nkc
yksgs ds uyksa esa ispksa ls LFkkfir
U;wure otu 15 feeh- 90
xzke

23.10 11.60

347

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
Table (Contd)....
BALL VALVES

18128 Ball valves high


pressure of PTMT with
epoxy
coated
Aluminium rod &
highdensity plastic ball
screwed for iron pipe
and fixed. (Minimum
weight 15mm-142gms/
20mm-210gms./
25mm-455gms/ 40mm

- 690 gms)

Rs.

Rs.

Rs.

Rs.

126.00 168.60 339.40 660.00

xksy ckYo 1
Rs.
Rs. 18128 xks y okYo] mPp nkc
ihVh,eVh] mPp ?kuRo dh
,iks{kh yis p<h ,Y;qehfu;e
NM ds lkFk yksgs ds uyks esa
ispksa ls LFkkfir fuIiy@dksj
U;w u re otu 15feeh142xzke@20feeh- 210xzke@
25feeh- 455xzke@40feeh 690xzke
23.10 11.60
5

NLPPLES/FLANGE
18129 Nipple suitable for
HDPE water tank.
(Minimum weight 15
mm-38gms/20mm45gms /25mm- 65gms)

18130 PTMT extension Nipple.


(Minimum weight

15mm-18 gms)
18131 PTMT flange, (Minimum
weight 15mm-5gms)

EACH
WASTE COUPLINGS

18132 Waste coupling of PTMT


(half or full threaded) .
(Minimum weight 32mm
45gms/40mm-60 gms)
18133 Ditto but suitable for
urinals, (Minimum weight

32mm-45gms

29.60

35.80

67.00

4.60

2.30

30.00

9.30

4.60

11.90

4.60

2.30

S&F
Bore dia of
discharge pipe (mm)

Fixing
only

Add if
fixed in
repairs

NksM+us okyh uyh


ds Nsn dk O;kl fe-eh

dsoy
LFkkiu

tksMs+ ;fn
ejEer esa

32

40

Rs.

Rs.

Rs.

Rs.

60.50

80.30

23.10

11.60

79.20

23.10

412.70

443.20

23.10

18131 ihVh,eVh dksjnkj U;wure


otu 15feeh- 5xzke
iz R ;s d
vif'k"V ;q X es a

18132 vif'k"V ;qXe] ihVh,eVh dk cuk]


vk/kk ij iwjk pwMhnkj U;wure otu
32 feeh- 45xzke@40feeh- 60xzke

11.60

18133 mi;qZDr fdUrq ew=ikrks ds fy,


;Fkk;ksX; U;wure otu 32 feeh 45xzke

11.60

cksry Qans
18134 ihVh,eVh dh cuh cksry Qan
vojks/kh 25 feeh ikuh dh lhy
U;wure otu 32feeh- 260xzke@
40feeh- 270xzke

BOTTLE TRAP
18134 Bottle trap of PTMT
having minimum water
seal of 25mm .(Minimum
weight 32mm-260gms/

40mm-270 gms)

fuIiy@dks j nkj
18129 ihVh ,e Vh fuIiy ,p Mh
ih bZ ikuh ds Vsad ds fy,
U;w u re otu 15feeh38xzke@20feeh- 45xzke@
25feeh- 65xzke
18130 ihVh,eVh foLrkj fuIiy
U;wure otu 15feeh- 18xzke

348

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
EACH
GRATINGS
18135 Grating doom 100mm dia of PTMT

(Minimum weight 25gms)


18136 Grating doom 125 mm dia with waste hole

of PTMT. (Minimum weight 40gms)


18137 Grating round 140 mm size of PTMT.

(Minimum weight 50gms)


18138 Grating square 150 mm size of PTMT

(Minimum weight 100gms)

S&F
Rs.

18135
38.70

18136
42.20

18137
53.90

18138
109.20

18139 Ditto but with waste hole of PTMT.

(Minimum weight 100gms)

18139

18140 Grating square fitting of size 150mm made


in two parts for smell and mosquito
proofing with minimum 25 mm water seal

of PTMT. (Minimum weight 85gms)

18140

18141

18141 Grating square (SLIT) 150mm of PTMT.

(Minimum weight 100 gms)

SHOWERS
18142 Swivel shower of PTMT any colour for
fixing with 15mm pipe. (Minimum weight

40gms)
18143 Shower arm 15 mm size, 195mm long with
bend of 45degree with flange of PTMT any

colour.(Minimum weight 40gms

104.50

84.50

QOokjs
18142 ?kweus okyk QOokjk ihVh,eVh dk cuk fdlh Hkh jax
dk 15feeh U;wure otu 40xzkeA

18143 QOokjs dh Hkqtk] 15feeh 195 feeh yEck 45 fMxzh


eksM dksj;qDr] ihVh,eVh dh cuh] fdlh Hkh jax dh
U;wure otu 40xzke

SHELF

18144

18144 Shelf of PTMT fixed with and including


Chromium plated brass screws and
wooden/plastic cleats (Minimum weight

300gms)
227.70
LIQUID SOAP CONTAINER
18145 Liquid soap container of PTMT fixed with
and including Chromium plated brass
screws and wooden/plastic cleats.

(Minimum weight 105gms)

126.60

TOWEL RING/RAIL
18146 Towel Ring of PTMT fixed with and
including Chromium plated brass screws
and wooden/plastic cleats (Minimum

weight 90gms)

133.70

iz R ;s d
tkfy;ka
100 fe-eh O;kl dk tkyhnkj Mwe ihVh,eVh dk
cuk U;wure otu 25 xzke
125 feeh- O;kl dk tkyhnkj Mwe] vif'k"V Nsns
lfgr] ihVh,eVh ds cusA U;wure otu 40xzke
140 feeh vkdkj dh xksy tkyh] ihVh,eVh dh
cuh U;wure otu 50xzkeA
oxkZdkj tkyh] 150 feeh] vif'k"V Nsn lfgr]
ihVh,eVh dh ceh U;wure otu 100xzkeA
mi;wZDr] fdUrq ihVh,eVh ds vif'k"V Nsn lfgr
U;wure otu 100xzke
oxkZdkj miLdj tkyh 150 feeh vkdkj dh] nks
Hkkxks es cuh] xU/k vkSj ePNj vojks/kh 25 feeh ikuh
dh lhy ds lkFk tks fd ihVh,eVh dh cuh gks
U;wure otu 85xzkeA
oxkZdkj tkyh ,l ,y vkbZ Vh 150 feeh] ihVh,eVh
dh cuhA U;wure otu 100xzke

'kS Y Q
ihVh,eVh dh 'kSYQ] ksfe;e ijr p<s ihry ds
ispksa vkSj ydMh@ IykfLVd ds DyhV ls LFkkfir]
vkSj lfgr U;wure otu 300 xzkeA

rjy lkcq u nkuh


18145 rjy lkcqunkuh] ihVh,eVh dh cuh] ksfe;e ijr
p<s ihry ds ispksa vksj ydMh@ IykfLVd ds
DyhV ls LFkkfir vkSj lfgr] u;wure otu 105
xzkeA
rkSfy;k Vkxus dk ?ksjk@iVfj;k
18146 ihVh,eVh dk cuk rkSfy;k Vkxus ds ?ksjk] ksfe;e
ijr p<s ihry ds ispksa vksj ydMh@IykfLVd ds
DyhV ls LFkkfir vkSj lfgr] U;wure otu 90xzke

349

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
EACH

S&F

18147 Towel Rail 450mm long of PTMT fixed with


and including Chromium plated brass
screws and wooden/plastic cleats

(Minimum weight 170gms)

18147

Rs.

235.90

18148

18148 Towel Rail 600mm long of PTMT fixed with


and including Chromium plated brass
screws and wooden/plastic cleats.

(Minimum weight 190gms)


259.40

iz R ;s d
ihVh,eVh dk cuk rkSyh;k Vkaxus dk iVfj;k 450feeh
yEck] ksfe;e ijr p<s ihry ds ispksa vksj
ydM+h@IykfLVd ds DyhV ls LFkkfir vkSj lfgr]
U;wure otu 170xzke
ihVh,eVh dk cuk rkSyh;k Vkxus dh iVfj;k 600feeh
yEck] ks f e;e ijr p<s ihry is p ks a vks j
ydM+h@IykfLVd ds DyhV ls LFkkfir vkSj lfgr]
U;wure otu 190 xzke

URINAL SPREADER
18149 Urinal spreader of PTMT any colour for
fixing with 15 mm dia pipe. (Minimum

weight 60gms)

118.40

18149 ew= ik= LizM


S j ih Vh ,e Vh dk ew=ik= LizM
S j] fdlh
Hkh jax dk] 15 feeh- C;kl uy ds lkFk LFkkfir
U;wure otu 60 xzke

PVC CONNECTIONS
18150 PVC connections 15mm size with PTMT

nuts of length 300mm

56.30

18151 Ditto but length 375mm

58.60

18152 Ditto but length 450mm

73.90

18153 Ditto but length 600mm

79.80

18154 Ditto but length 750mm

85.60

18155 Ditto but length 900mm

91.50

18151
18152
18153
18154
18155

18150

ih oh lh duSD'ku
ihohlh duSD'ku] 15 feeh vkdkj ds 300 feeh
yEckbZ dh ihVh,eVh dh f<cfj;ksa lfgrA
mi;qZDr fdUrq 375 feeh yEckbZ dhA
mi;qZDr fdUrq 450 feeh yEckbZ dhA
mi;qZDr fdUrq 600 feeh yEckbZ dh
mi;qZDr fdUrq 750 feeh yEckbZ dh
mi;qZDr fdUrq 900 feeh yEckbZ dh

SOIL, WASTE AND VENT PIPES


iqjh"k] voty rFkk laokrh uy
(a)

The measurement of pipes shall be net as fixed between


the fittings including short lengths, without any
allowance for cutting and waste or for the portions of
pipes entering the sockets of the adjacent pipe or fitting.
Fittings and accessories such as bends, branches, sockets
etc.; shall be enumerated afterwards and measured
separately. Rates include for all necessary extra joints,
cutting and waste.

d miLdjksa ds chp ls yxs uyksa dh uki vYi yEcku uyksa lfgr


dksjh yh tk;sxh] dVkbZ o {k;] ;k uy ds og Hkkx tks lkfdV
ds vUnj gksdj lkFk ds uy ;k miLdjksa esa yxs gSa ds fy;s
fcuk vfrfDr fn;sA miLdj ,oa iwjd tSls eksM+ 'kk[kk;sa
lkfdV vkfn ckn esa fxuh tk;sx
a h rFkk izFkd ekih tk;sx
a hA njsa
lHkh vko';d vfrfjDr] tksM+] dVkbZ o Nhtu lfgr gSaA

(b)

The rates for 'except pipes' or 'except fitting' include for


supply of pipe nails, distance pieces, plugs, holder bats
etc., and all jointing materials and also for all necessary
cutting of pipes and jointing and fixing in position. The
rates for 'supplied and fixed' include subsidiary
materials, mentioned above and pipes, fittings and
accessories and also waste arising from cutting of pipes.

[k ^uy jfgr* ;k ^miLdj jfgr* dh njksa esa uy dhysa] varj.k


mikax] Iyx idM+ ioZ vkfn dh vkiwfrZ vkSj reke tqM+ko
lkexzh rFkk lHkh vko';d uy dVkbZ o tqM+kbZ o ;FkkLFkku
fLFkj djuk Hkh 'kkfey gSA vkiwfrZ o LFkkiu dh njsa mi;qZDr
iwjd lkexzh rFkk uy] miLdj ,oa lgk;d mikax rFkk uy
dVkbZ esa gqbZ laHkkfor {kfr lfgr gSaA

(c)

The rates in the following tables for cast iron soil, waste
and vent pipes and the fittings are for jointing with
cement mortar. In case the pipes and fittings are to have
lead joints, shall be enumerated and measured extra over
cement joints vide item 18207.

fuEu lwph dh njsa] yksgs ds <ys ey] vif'k"V o laokrh uyksa


,oa miLdj dks lhesaV elkys esa tksM+us ds fy, gSaA tgka uy
o miLdj lhlk esa tqM+h gksa mudh fxurh o eki en 18207
esa lhesaV tksM+ ds vfrfjDr gksxhA

350

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
SOIL, WASTE AND VENT PIPES Contd...
iqjh"k] voty rFkk laokrh uy tkjh
(d)

In minor repairs, where plpes are necessarily to be


cut to lengths, an allowance shall be made for each
cut as follows:
1. When pipe is supplied by the contractor50cm
run (supplied and fixed).
2. When pipe supplied by M.D. for fixing only
cutting only.

?k

vYi ejEer esa tgka uy vko';d :i ls yEckbZ esa dkVus gSa


ogka izR;sd dkV ds fy, vfrfjDr Hkqxrku bl izdkj gksxk%&

tgka uy dh vkiwfrZ Bsdns kj }kjk gks& 50 lseh ju vkiwfrZ o


fLFkj.k
tgka uy dh vkiwfrZ ,e Mh }kjk dsoy LFkkiu ds fy;s gks &
dVkbZ dsoy

CAST IRON SOIL, WASTE AND VENT PIPES


<ys yksgs ds iqjh"k] voty rFkk laokrh uy
Supplied and fixed

PER RUNNING
METRE

Except pipe,
any type

vkiwfkZ ,oa LFkkiu

fcuk uy] fdlh


vkdkj ds
uy dk O;kl feeh esa 18156 <ys yksgs ds iqjh"k]
voty o laokrh uy
100
50
75
100
fdlh yEckbZ esa [kqys
Rs.
Rs.
Rs. Rs.
;k cUn lhesaV tksM+
ds lkFk [kkb;ksa ;k Q'kks
580.60 10.00 10.50 11.00
esa ncs gq;s
18157 mi;qDZ r] fdUrq nhokjksa
641.60 68.00 70.00 72.00
esa LFkkfir

Spun pipes

Sand cast pipes

dkrs gq, uy

ckyq jfpr uy

Bore of pipe in mm
18156 Cast iron soil, waste
75
100
50
75
and vent pipes in any 50
Rs.
Rs.
Rs.
Rs.
length with or without Rs.
ears, with cement
joints, laid in trenches
538.74 595.00 691.20 482.00 493.50
or in floors
18157 Ditto, but fixed to walls
596.80 654.50 752.20 540.00 553.00

iz f r ehVj

FITTINGS FOR CAST IRON PIPES


<ys yksgs ds uy gsrq miLdj
EACH

18158 Bends (any radius),


diminishing pieces or
tapers (larger bore

measured)
18159 Bends (any radius)
with duck's foot or

heel rest
18160 Branch pieces, single
(equal or unequal),
ordinary or inverted
(spigot or socket type)
or with parallel

branches

Supplied and fixed

Except fittings any type

vkiwfrZ ,oa LFkkiu

miLdj jfgr fdlh vkdkj ds

Bore of pipe in mm

uy dk O;kl feeh esa

50

75

100

50

75

100

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

256.60

337.10

414.00

68.60

70.60

72.00

340.00

396.30

537.80

68.60

70.60

72.00

221.30

258.60

295.30

68.60

70.60

72.00

iz R ;s d

18158 eksM+] dksbZ O;kl U;wud


[kaM ;k Qans cM+k Nsn
ekik tk;sxk
18159 eksM+ dksbZ O;kl frnkjh
;k piVs ikn ds lkFk
18160 'kk[kk mikax ,dy le
;k vle lk/kkj.k ;k
myVs MkVnkj ;k ldksVj
;k lekukUrj 'kk[kk ds
lkFk

351

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
SOIL, WASTE AND VENT PIPESContd.

iqjh"k] voty rFkk laokrh uy tkjh


<ys yksgs ds uy gsrq
miLdj tkjh

FITTINGS FOR
CI PIPESContd.

EACH

18161 Ditto, but double

Supplied and fixed

Except fittings any type

vkiwfrZ ,oa LFkkiu

miLdj jfgr fdlh vkdkj ds

Bore of pipe in mm

uy dk O;kl feeh esa

50

75

100

50

750

100

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

751.10

77.80

79.90

81.30

371.60 547.20

18162Sockets (double) collars


222.90 230.20

iz R ;s d

18161 mi;qZDr] fdUrq ;qxy

18162 lkdsV ;qxy dkyj


280.80

68.60

70.60

72.00

18163 yEcs xzhok ;k [klds


152 feeh rd iz{ksi

18163Swan necks (or off- sets)


upto 152 mm projection

221.30 290.00
18164Ditto exc 152 mm but n
281.30 337.10
exc 305 mm projection

431.40

68.60

70.60

72.00

524.40

68.60

70.60

72.00

18164 mi;qDZ r 152 feeh ls vf/kd


fdUrq 305 feeh iz{ksi

ACCESSORIES FOR
CAST IRON PIPES

18165 vfrfjDr dsoy en 18158


ls 18164 ij pfn v.Mkdkj
igqp }kj ds lkFk LFkkfir
gks
<ys yksgs ds uyks gsrq
iwjd lkexzh

EACH

iz R ;s d

18165Extra only on items18158


to 18164 if fitted with oval

access doors

18166Traps P or S

18167Ditto with vent horn


18168Cast iron cowls

29.40

32.90

44.60

283.70 404.00

496.10

31.50

34.30

37.70

207.70 328.00

544.00

31.50

34.30

37.70

174.00 221.00

272.00

16.50

19.40

21.70

Supplied and fixed

vkiwfrZ ,oa LFkkiu


18169Stack clamps out of 50
Bore of pipe in mm
mm by 5 mm flat iron
uy fNnz feeh esa
and 16mm dia round
iron stays, including
50
75
100
bolts and nuts and
Rs.
Rs.
Rs.
securing ends of stays to
112.20 114.50 116.90

wall or roof

Fixing only
any dia

18166 Qans ih ;k ,l
18167 mi;qZDr] fudkl rqjgh ds
lkFk
18168 <ys yksgs dh Vksfi;ka

Add if Fixed

dsoy LFkkiu tksMsa ;fn ejEer 18169 lh/ks f'kdats 50x5 feeh
dksbZ O;kl
esa fLFkj
ds likV yksgs ls cus ,oa
16 feeh O;kl ds xksy Vsd
okys] dkoys f<ofj;ksa lfgr
Rs.
Rs.
vkSj Vsadksa ds fdukjksa dk
22.90
10.00
nhokj ;k Nr esa nckuk

352

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
AC SOIL, WASTE AND VENT PIPES
,sLosLVl lhesaV ds iqjh"k] voty o laokrh uy rFkk miLdj
PER RUNNING METRE

Supplied and fixed

Except pipes of fittings

vkiwfrZ ,oa LFkkiu

uy ;k miLdj jfgr
Nsn feeh esa

Bore in mm
18170Asbestos cement pipes
in any length with
cement joints; fixed to

walls

50

80

iz f r ehVj

100

50

80

100

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

109.30

149.50

170.90

48.90

61.50

72.60

18170 ,sLosLVl lhesaV uy fdlh


yEckbZ esa lhesaV tksM+
lfgr nhokjksa esa LFkkfir
,sLoslVl lhesaV uyksa ds
miLdj

FITTINGS TO AC PIPES

iz R ;s d

EACH
18171Bends plain
radius)

(any

18172Junction, single, equal


or unequal, ordinary
or inverted with spigot
or socket branch
18173Junction, double ditto

18171 eksM+ lkns dksbZ O;kl


37.40

49.50

69.10

12.60

20.60

35.00

62.80

80.40

103.10

17.40

28.80

42.30

70.50

112.00

150.00

25.90

41.90

62.10

7.60

10.00

12.30

18175Loose socket

24.80

28.60

34.80

12.50

13.70

14.20

49.80

54.70

60.30

12.60

13.70

14.20

53.90

59.10

66.70

12.60

13.70

14.20

70.40

75.60

80.30

12.60

13.70

14.20

18176Swan necks upto 15cm

projection
18177Ditto exc 15cm but n.
exc 30cm projection

18172 laf/k] ,dy] le ;k vle]


lkekU; ;k myVs] MkV ;k
ldksVj 'kk[kk
18173 laf/k f}'kk[kk] mi;qDZ r

18174 tksM+ a s en 18171 ls 18173 esa


;fn igqp
a }kj O;ofLFkr gS

18174Add to items 18171 to


18173 if provided with

access door

18175 <hys ldksVj


18176 yEcku xzhok 15 ls-eh- mHkkj

ACCESSORIES FOR
AC PIPES

18177 mi;qDZ r 15 ls-eh- ls vf/kd


fdUrq 30 ls-eh- ls vuf/kd
mHkkj
18178 mi;qDZ r 30 ls-eh- ls vf/kd
fdUrq 60 ls-eh- ls vuf/kd
mHkkj
,LosLVl lhesaV uyksa gsrq
iwjd lkexzh

EACH

iz R ;s d

18178Ditto exc 30cm but n.

exc 60cm projection

18179Slotted vent cowl

26.30

39.80

48.20

9.90

10.90

11.40

18179 [kkapns kj fljs okys laokrh


<akih Vksih
18180 uksdnkj Vksih <akih

46.40

52.20

56.90

9.90

10.90

11.40

18180Cone cap cowl

353

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
PVC SOIL, WASTE AND RAINWATER (SWR) DRAINAGE PIPES

ihohlh iqjh"k] voty o ojlkrh ikuh lhoj fudkl uy


S&F

Except pipes

vkiwfrZ ,oa LFkkiu

uy jfgr
Nsn feeh esa

PER RUNNING METRE

Bore im mm
18181 PVC (SWR) pipes single
socketed, in any length
with rubber ring joints, laid
in trenches or in floors

75

110

75

110

Rs.

Rs.

Rs.

Rs.

132.20

232.20

16.30

20.40

iz f r ehVj

18181 ihohlh lhoj ,dy dksVj ds


ldksVjh uy] fdlh yEckbZ esa
jcM+ NYys ds tksM ds lkFk
[kkbZ;ksa ;k Q'kkZs esa fcNk;s x;s

18182 Ditto but double socketed

18182 mi;qZDr] fdUrq nksgjs dksVj


149.70

259.40

20.40

24.30

18183 PVC (SWR) pipes single


socketed in any length
with rubber ring joints

fixed to walls

151.00

251.80

40.30

42.20

18184 Ditto but double socketed

168.70

291.00

53.50

55.60

18183 ihohlh lhoj ,dy dksVj ;qDr


uy jcM+ ds lkFk fdlh yECkkbZ esa
fjax tksM+ ds lkFk nhokj esa yxs
18184 mi;qZDr] fdUrq nksgjs dksVj

FITTINGS FOR PVC (SWR) PIPES

ihohlh lhoj uyksa ds miLdj


S&F

Except fittings

vkiwfrZ ,oa LFkkiu

miLdj jfgr
Nsn feeh esa

EACH

Bore im mm
18185 PVC (SWR) bends any

radius
18186 PVC (SWR) branch piece,
single (single Y) equal or

unequal
18187 PVC (SWR) branch piece,
double (double Y) equal or

unequal
18188 PVC (SWR) junction single,
(Single T) equal or unequal
18189 PVC (SWR) junction double,
(double T), equal or unequal
18190 Add to items 18185 to 18189 if

provided with access door


18191 PVC (SWR) couplers

18192 PVC (SWR) reducers

75
Rs.
75.74

110
Rs.
128.84

75
Rs.
21.69

110
Rs.
36.60

18185 ihohlh lhoj cSM


a fdlh O;kl ds

18186 ihohlh lhoj 'kk[kk [kaM ,dy


,dy Y le ;k vle
133.20

224.90

29.80

43.90

191.30

282.60

43.30

64.00

112.10

193.10

29.80

43.90

187.80

279.10

43.30

43.90

13.50

18.20

63.90

85.90

16.70

17.60

18187 ihohlh lhoj 'kk[kk [kaM nksgjs nksgjs


Y le ;k vle
18188 ihohlh lhoj laxe ,dy
,dy T le ;k vle
1818
181899 ihohlh lhoj laxe nksgjs nksgjs
T le ;k vle
18190 tksMa+s en 18185 ls 18189 esa ;fn
igaqp }kj dh O;oLFkk gS
18191 ihohlh lhoj ;kstd

18192 ihohlh lhoj U;qud

78.90

16.70

17.60

77.20

13.80

14.90

18193 PVC (SWR) vent cowl

iz R ;s d

65.30

18193 ihohlh lhoj laokrh Vksih

354

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
FITTINGS FOR PVC (SWR) PIPESContd...

ihohlh lhoj uyksa ds fy;s miLdj tkjh


EACH

S&F

Except fittings

vkiwfrZ ,oa LFkkiu

miLdj jfgr
Nsn feeh esa

Bore im mm
125/110

110/110

125/110

110/110

Rs.

Rs.

Rs.

Rs.

18194 PVC (SWR) 'P trap

18195 PVC (SWR)Q trap

353.30

315.50

36.10

35.90

447.30

400.10

36.10

35.90

18196 PVC (SWR) 'S' trap

467.30

418.90

36.10

35.90

iz R ;s d

18194 ihohlh lhoj ^P* Qans


18195 ihohlh lhoj ^Q* Qans
18196 ihohlh lhoj ^S* Qans

CONNECTORS

la ; ks t d
EACH

S&F

Except
fittings

vkiwfrZ ,oa
LFkkiu

miLdj
jfgr

18197100mm cast iron sanitary connection

socket to fit WC out-let

Rs.

Rs.

125.30

11.40

18198100mm cast-iron sanitary connection


bend (92 0 ), with arms 380 to

450mm, excluding joint

332.50

58.20

18199100mm cast iron sanitary connection


S branch, with branch 370 to

450mm long excluding joint

440.90

58.20

396.60

58.20

468.30
543.80

12.40
15.80

320.40

11.40

18200Ditto, P branch, with branch 375 to

450 mm long, ditto


18201100mm cast iron bossed pipe basin
and bath connector, single (for one

pipe system)

18202Ditto, double (ditto)


18203100mm cast iron sanitary
connectionsshort connections pipe

of length upto 300 mm


18204 100mm, asbestos cement sanitary
bend, with 300 to 450 mm long

socketed branch, excluding joint

167.20

10.90

18205 110mm PVC (SWR) WC connector

with lip ring

195.20

21.30

18206 110mm PVC (SWR) WC connector

bent type

207.00

21.30

iz R ;s d

18197 100 feeh <ys yksgs ds LoPNrk la;kstu


ldksVj tyeyk/kkj fudkl ds mi;qDr
18198 100 feeh <ys yksgs ds LoPNrk la;a kstu eksM+
(920) 'kk[kk] 380 ls 450 feeh yEcs] tksM+
jfgr
18199 100 feeh <ys yksgs ds LpPNrk la;kstu
^,l* 'kk[kk] 370 ls 450 feeh yEcs] tksM]
jfgr
18200 mi;qDZ r] ^ih* 'kk[kk] 375 ls 450 feeh yEch
'kk[kk] mi;qZDr
18201 100 feeh <ys yksgs ds mHkM+s uy csflu rFkk
Luku la;kstd] ,dy 'kk[kk ,d uy i}fr
18202 mi;qDZ r] fn'kk[kk mi;qZDr
18203 100 feeh ds <ys yksgs ds LoPNrk la;kstu
vYi la;kstu uy] 300 feeh rd yEcs

18204 100 feeh ds ,slcsLVl lhesaV ds LpPNrk


eksM]+ 300 ls 450 feeh- dksVj 'kk[kk lfgr]
tksM jfgr
18205 110 feeh ds] ihohlh lhoj ds pkSapnkj
NYys lfgr tyeyk/kkj la;kstd
18206 110 feeh ihohlh lhoj ds >qdkoh fdLe
ds] tykeyk/kkj la;kstd

355

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
JOINTS

la ; ks t d
The rates for jointing in repairs include for hacking out cement
joints or burning out lead joints and collecting useful materials
and removing them to stores.
EACH

ejEerksa esa tksM+us dh bu njksa esa] lhesaV tksM+ m[kkM+uk ;k lhlk


Vkadh tksM+ksa dks tykdj fudkyuk vkSj mi;ksxh lkexzh dks ,d=
djds Hk.Mkj esa igqpkuk 'kkfey gSA
iz R ;s d

Materials and labour

lkexzh ,oa Je
Bore of pipe in mm
18207Extra over cast iron pipes
and fittings if lead joint is
provided in lieu of cement
joint

18208Jointing only cast iron pipes


and fittings or AC pipes and
fittings, in repairs, with
cement joints

50

uy dk O;kl feeh esa


75
100

Rs.

Rs.

Rs.

178.20

283.10

353.30

31.50

36.90

42.30

18207 vfrfjDr] <ys yksgs ds uy o miLdjksa


ij ;fn lhesVa tksMk+ s ds LFkku ij
lhls dh Vkadh ls tksM+ dh O;oLFkk
gS
18208 dsoy la;kstu] <ys yksgs ds uyksa o miLdjksa
;k ,slcsLVl lhesVa uyksa o miLdjksa ds
ejEer esa lhesVa tksM+ ds lkFk

TRAPS FOR BASINS AND SINKS

/kkou ik= o gkSnh gsrq Qans


iz R ;s d

EACH
Bore of trap in mm
18209 Brass chromium plated trap P or
S pattern for wash basins and sinks
with inlet and outlet, screwed for pipe
or connections, and with one cleaning

cap and fixed

Qans dk Nsn feeh esa


32

40

Rs.

Rs.

170.90

193.10

18210Brass chromium plated bottle traps


for wash basins with inlet and outlet
screwed for pipe or connections
including necessary packing, union

and cap and fixed

479.20

561.40

18211Add if fixed in repairs, including

removing old trap to store

19.60

22.90

18209 /kkou ik= vkSj gkSnh esa ,d fudkl Vksih


okys ihry ds ksfe;e ih ;k ,l uewus
ds Qans( ,d fudkl Vksih ds lkFk
la;kstuksa ;k uy ds fy,
18210 /kkou ik= ds fy;s ihry ksfe;e ds fy;s
pwM+h dVs] cksry Qans uy ;k la;kstu ds
fy, pwM+h dVs] izos'k o fudkl }kj okys]
vko';d ca/kkbZ] ;qXey rFkk Vksih lfgr
18211 tksfM;s] ;fn ejEerksa esa yxs gSa] rFkk
iqjkus Qanksa dks Hk.Mkj esa igqpkus lfgr

356

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
FLOOR AND NAHANI TRAPS

Q'kZ rFkk ukgk.kh Qans


EACH

iz R ;s d

M&L

Except traps

lkexzh ,oa Je

Qans jfgr
fudklh O;kl feeh esa

Diameter of outlet in mm

18212Cast iron floor trap, with


50
75
100
50
75
100
grating including jointing
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
to waste pipe fixed in
cement concrete type B-1
411.20 481.70 647.40 118.70 123.80 134.30
(1:2:4)

18212 <ys yksgs ds tkyh ds lkFk Q'kZ


Qans vouy esa lhesVa dahV ch1
1%2%4 Hkjdj tksM+ lfgr

18213Cast iron Nahani trap ditto

18213 <ys yksgs ds ukgk.kh Qan]s mi;qDZ r

434.60 502.80 715.20 129.10 135.60 139.40


EACH

Except traps

lkexzh ,oa Je

Qans jfgr
fudklh O;kl feeh esa

Diameter of outlet in mm
18214 PVC (SWR) floor trap, plain
with grating including
jointing with solvent

cement

iz R ;s d

M&L

50

63

75

50

63

75

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

18215 PVC (SWR) multi floor trap


with grating including
jointing with solvent

cement

129.20 176.20

37.70 42.30 46.90

18214 ihohlh lhoj ds lknk Qans]


lkFk esa tkyh] foyk;d lhesaV
tksM lfgr
18215 ihohlh lhoj ds tkyh lkFk
cgqQ'khZ Qan]s foyk;d tksM+ lfgr

383.10 387.70

37.70 42.30 46.90

GULLY TRAPS

dqafMdk Qans
EACH
18216PVC (SWR) gully trap 125/110 mm,
setting and jointing with solvent

cement

M&L

Except traps

lkexzh ,oa Je

Qans jfgr

Rs.

Rs.

382.50

40.00

iz R ;s d
18216
18216ihohlh ds 125@110 feeh LFkj.k ds dqfa Mdk
Qans rFkk foyk;d lhesaV ls tqM+s

SUB-SECTION C DRAINS

miHkkx lh ukfy;ka
CONCRETE FOUNDATION BEDS, ETC. TO DRAIN PIPES
(a)

(b)

dahV ds uho vk/kkj vkfn fudklh uyksa ds fy,


The rates for concrete beds to drain pipes cater for the d fudklh uyksa ds dahV vk/kkj dh bu njksa esa fuEu pkSMk+ bZ rFkk
following widths and thickness.
eksVkbZ dk izko/kku gS%
(i) Thickness of bed below the barrel of pipes: 10cm for
(i) uy ds ry ds uhps vk/kkj dh eksVkbZ% 100 rFkk 150
pipes 100 mm and 150mm dia and 15cm for pipes
feeh O;kl ds uy ds fy, 10 lseh rFkk 200 feeh ;k
200mm dia and over.
vf/kd O;klokys uyksa ds fy, 15 lseh
(ii) Width of bed: Outer diameter of drain pipes (not of
(ii) vk/kkj dh pkSM+kbZ% fudklh uy ldksVj@dkyj dk
sockets/collars) plus 30 cm.
ugha dk okgjh O;kl tek 30 lseh
If thicker beds or surrounds are ordered, the thickness of [k ;fn vk/kkj ;k ?ksjs dh vf/kd eksVkbZ dh vkKk nh tkrh gS] rks
concrete shall be measured as concrete in foundations.
dahV dh eksVkbZ dh uki] uhoa esa dahV* ds leku gksxhA

357

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
CONCRETE FOUNDATION BEDS, ETC. TO DRAIN PIPESContd...
dahV ds uhoa vk/kkj vkfn fudklh uyksa ds fy, tkjh
(c)
(d)

x bu njksa esa vko';d r[rk cUnh rFkk vcyEou vFkok ;k >ky


ij vk/kkj fcNkuk 'kkfey gSA
Excavation, refilling, etc., of trenches shall be measured ?k [kkb;ksa dh [kqnkbZ] HkjkbZ vkfn izFkd ekih tk;saxhA
The rates include for any necessary shuttering and
supports to concrete and for laying beds to falls.
separately.

PER RUNNING
METRE

18217Concrete bed
to drain pipes
including
forming cradles;

in
18218Concrete bed
to drain pipes
including
packing under,
and haunching
against
the
sides of pipes
after they are
laid and tested;

in
18219Concrete bed
to drain pipes
including
packing under
and completely
surrounding
pipes with
concrete after
they are laid and

tested; in

Cement concrete
1:3:6 type C-2

Cement concrete
1:4:8 type D-2

lhesVa dahV
Vkbi&lh&2 1%3%6

lhesVa dahV
Vkbi&Mh&2 1%4%8

Lime concrete with


lime mortar 1:2 (lime
sand/surkhi) and
using brick coarse
aggregate

pwuk dahV pwuk elkyk


1%2 1 pwuk%2 ckyq@lq[khZ
rFkk bZV dh jksM+h dk
iz;ksx djds
Bore of pipe in mm

uy dk O;kl feeh esa


100

150

200

300

100

150

200

300

100

150

200

300

116.00 138.90 201.40 234.40 106.60 126.50 181.00 210.10 114.80 135.80 197.40 230.00

162.40 194.40 281.90 328.20 149.20 177.20 253.40 294.20 162.30 190.20 276.40 322.00

208.80 250.00 362.40 421.90 191.80 227.80 325.80 378.20 206.60 244.50 355.30 414.00

iz f r ehVj

18217
18217fudkl uy ds
fy, voya c u
xBu lfgr dahV
vk/kkj
18218
18218fudkl uy dk
dahV vk/kkj uhps
dh dqVkbZ vkSj tc
uy fcNk fn;s
tk;sa rFkk tkap
fy, tk;sa rc uy
ds cxyksa dh HkjkbZ
lfgr
18219
18219fudkl uy dk
dahV vk/kkj rFkk
uhps dh dqVkbZ
vkSj tc uy fcNk
fn;s tk;sa rFkk
tkap fy;s tk;sa
rc uy ds pkjksa
vksj dahV HkjkbZ
lfgr

358

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
SALT-GLAZED STONEWARE DRAIN PIPES
'kksjs ;qDr iRFkj ds fudkl uy
(a)

(b)

(c)

The rates include for laying pipes level or to falls in


trenches, on concrete bed or directly on hard
grounds as indicated and making joints and testing
as specified. Excavation and earthwork shall be
measured separately.
The measurements shall be net as fixed between the
fittings without any allowances for cutting and
waste. Fittings such as bends, junctions, etc. shall be
enumerated afterwards and measured separately. Rates
include all necessary extra joints, waste and cutting.
The rates given in the following table are for pipes
and fittings of grade 'A'. If grade 'AA' pipes and
fittings are ordered, 'Materials and labour' rates shall
be increased by 3 percent and 'Supply only' rates
shall be increased by 5 percent.

PER RUNNING METRE

d bu njksa esa uyksa dks lery ;k [kkb;ksa es]a dahV ds vk/kkj ;k


lh/ks dBksj Hkwfe ij] tSlk funsZ'k gks] fcNkuk vkSj tksM+ Hkjuk
o izko/kku ds vuqlkj tkap djuk 'kkfey gSA [kqnkbZ rFkk feh
dk dk;Z izFkd ekis tk;saxsA
[k eki miLdjksa ds chp ls dVkbZ ;k {kfr dk fcuk dksbZ ykHk fn;s
'kq) dh tk;sxhA miLdj tSls] eksM+] laxe vkfn ckn esa fxus
tk;sx
a s rFkk izFkd ekis tk;sx
a As bu njksa esa lHkh vko';d brj
tksM+] {k; o dkV 'kkfey gSaA
x uhps rkfydk dh njsa] *,* Js.kh ds uyksa vkSj miLdjksa ds fy,
gSa] ;fn *,,* Js.kh ds uyksa o miLdjksa dh vkKk nh tkrh gS
rks **lkexzh o Je dh njksa esa 3 izfr'kr vkSj **dsoy vkiwfrZ**
dh njksa esa 5 izfr'kr dh o`f} dh tk;sxhA

M&L

Except pipes, etc.

lkexzh ,oa Je

uy vkfn jfgr

iz f r ehVj

Internal diameter of pipe in mm


18220Sail-glazed stoneware
drain pipes laid in
trenches and jointed as

specified

uy dk Hkhrjh O;kl feeh esa


100

150

200

300

100

150

200

300

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

165.60 209.00 260.40 326.10 53.50 78.60 109.00 184.00

18220 'kksjs ;qDr iRFkj ds fudkl


uy [kkb;ksa esa fcNkuk rFkk
izko/kku vuqlkj tksMu+ k

FITTINGS FOR SALT


GLAZED STONEWARE
DRAIN PIPES

'kksjs eqyEek;qDr iRFkj


ds fudkl uy ds
miLdj

EACH

iz f r ehVj

18221 Bends and taper bends,

any radius

18221 eksM]+ Vsij eksM]+ fdlh O;kl


okys
18222 ,dy Y tksM+
18223 nksgjs Y tksM

18222 Single 'Y' junctions


18223 Double 'Y' junctions

100.10 133.90 174.90 283.30 29.60 39.90 45.60 63.60


139.70 157.70 243.60 301.10 51.20 68.80 79.00 101.40
199.10 243.50 305.40 377.40 67.90 90.70 105.70 142.40

359

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
REINFORCED CONCRETE DRAIN PIPES
izofyr dahV ds fudklh uy
(a)

The rates include for laying pipes level or to falls in


trenches, etc. on concrete bed or directly on hard ground
as indicated and making joints and testing as specified.

d bu njksa esa uyksa dks lrg ij ;k [kkb;ksa vkfn esa dahV ds


vk/kkj ;k lh/kk dBksj Hkwfe ij tSlk funsZ'k gks Mkyuk vkSj
izko/kku vuqlkj tksM+ yxkuk o tkap djuk 'kkfey gSA

(b)

The pipes shall be measured net as fixed between the


fittings and specials, if any, without any allowance for
cutting and waste.
Fittings and specials shall be measured separately. The
rates include for all necessary extra joints, waste, and
cutting etc. Excavation and earthwork shall be measured
separately.

[k uyksa dh eki miLdjksa o fo'ks"kkaxksa ds chp esa 'kq+) gksxh fcuk


fdlh dkV NkaV dk ykHk fn;sA

(c)

PER RUNNING METRE

x miLdj o fo'ks"kkax izFkd ekis tk;sx


a As njsa vko';d vfrfjDr
tksM+] {k; rFkk dVkbZ lfgr gSa [kqnkbZ o feh dk dk;Z izFkd
ekik tk;sxkA

Bore of pipe in mm

iz f r ehVj

uy dk fNnz feeh esa

18224Reinforced concrete
600
pipes, class NP2, laid 80 100 150 200 250 300 450
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
and jointed complete Rs.

with collars
186.70 230.60 283.30 345.90 420.70 552.70 870.00 1204.80
18225Ditto but class NP3
241.00 271.30 324.50 495.40 568.70 820.30 1402.20 1974.80
18226Ditto except pipe and
44.50 50.30 58.60 76.30 100.40 144.70 251.00 352.00
collar, any class

18224 izofyr dahV ,uih2 Js.kh


ds uyksa dks fcNkuk rFkk
+ j lai.w kZZ
dkyj lfgr tksMd
18225 mi;qZDr] fdUrq ,uih 3
Js.kh
18226 mi;qDZ r] fdlh Js.kh ds uy
o dkyj jfgr

CAST IRON PIPE


CONNECTIONS

<ys yksgs ds uy la;kstd

EACH

iz R ;s d

18227Bends, laid and jointed,


147.80 168.10 238.70 327.30 360.50 460.00 585.70 831.00
complete
18228All as in item 18227

except bends
38.00 43.00

51.00

57.00 60.90

74.60 109.80 179.10

18229Single 'Y' junctions laid


245.20 289.90 338.50 427.10 530.80 612.20 820.70 1019.20
and jointed, complete
18230Ditto except single 'Y'

junction

38.00 43.00

51.00

57.00 60.90

74.60 109.80 179.10

18227 eksM+] fcNs o tqMs+] laiw.kZ


18228 lo en 18227 tSlk] fdUrq
eksM+ jfgr
18229 ,dy Y tksM+ yxs o tqMs+]
lai.q kZ
18230 mi;qZDr] ,dy Y tksM+
jfgr

360

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
SALT-GLAZED STONEWARE GULLY TRAPS
'kksjs ;qDr iRFkj ds ukyhnkj Qans
The rates include far setting and jointing to drains with cement
mortar 1:1. All excavation and earthwork, concrete in beds,
surrounds, kerbs, etc. and cast iron grating, shall be measured
separately.
EACH

njksa esa fcBkuk vkSj 1%1 lhesaV elkys esa tksM+uk 'kkfey gSA [kqnkbZ
RkFkk feh dks dk;Z] dahV ds vk/kkj oxy rFkk ?kqeko vkfn cukuk
vkSj <ys yksgs dh tkyh] izFkd ekih tk;sxhA
iz R ;s d

Materials and labour

lkexzh ,oa Je
Size of gully traps in mm

tkyh Qans dk vkdkj feeh esa


100x
18231 Salt-glazed stoneware gully 100
traps, square or round Rs.

mouthed, tvpe 'P'


18232 Ditto, Type 'Q'
18233 Ditto, type 'S'

125x
100

150x
100

180x
100

150x
150

180x
150

Rs.

Rs.

Rs.

Rs.

Rs.

282.10 300.00 318.50 395.50 442.50 503.40


276.20 293.90 357.20 386.10 427.20 475.40
290.30 309.10 334.90 407.30 457.80 524.50

18231 'kksjs ;qDr iRFkj ds pkSdksj ;k xksy


eqg ds *P* vkdkj ukyhnkj Qans

18232 mi;qZDr] *Q* vkdkj


18233 mi;qZDr] *S* vkdkj

INTERCEPTING TRAPS
var%jks/kh Qans
EACH

Internal dia in mm

Hkhrjh O;kl feeh esa

iz R ;s d

18234 'kksjs ;qDr iRFkj ds pkSdksj okys var%jks/kh Qan]s


uy eks[kksa esa fudkl cukus ds fy;s 'kk[kk ds
Rs.
var%jks/kh o 1%1 ds lhesaV elkys esa fcBkuk]
leku O;kl ds uy ds leku pkSMk+ bZ o eksVkbZ
esa dahV Hkjuk lfgr rFkk Hkjus ds ckn dqVkbZ
djukA lhlk p<+s jksd dks yxkus ds fy,
'kk[kk dks lkQ djuk] tLrh p<s+ yksgs ds
fdjp tqMs+ ;k vU; Lohr uewus ds vkSj
tLrh yksgs dh <sdyh ;k ?kksM+h tLrh yksgs
dh tathj] dkaVk o NYys lfgr
913.50

18234Intercepting traps of salt-glazed


100
stoneware, with square ends to inspection
Rs.
arms for building flush into manholes and
setting in cement mortar 1:1 complete,
including concrete foundation of width
and thickness as for pipes of same dia
and haunching after setting. Cleaning
arm to include a glazed ware stopper,
galvanised iron bayonet joint (or other
approved pattern) and galvanised iron
lever (or trigger), galvanised iron chain,
661.60
hook and ring

150

TESTING DRAINS, ETC.


ukfy;ksa vkfn dh tkap
(a)

The rates for testing do not apply to new work which


includes for all testing, etc.

(b)

The rates include for removing and replacing gratings,


manhole covers, etc. and for providing all plant and
appliances necessary for obtaining access to the work to
be tested and carrying out the test. They also include for
provision of water in case of water testing, and
temporarily plugging of drains.

[k

tkap dh njsa uohu dk;ksZ ij ykxw ugha gksrh D;ksafd lHkh


izdkj dh tkap mlesa 'kkfey gSA
bu njksa essa esa tkfy;ksa esugksy ds <Ddu vkfn dks gVkuk]
nksckjk yxkuk rFkk ml LFky dk tk;tk ysus o tkap djus
ds dk;Z esa vko';d ;a= o vkStkj dh O;oLFkk djuk 'kkfey
gSA blesa] ikuh tkap ds ekeys esa ikuh dh O;oLFkk djuk
rFkk dqN le; ds fy, ukfy;ksa dks cUn djuk fufgr gSA

361

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
TESTING DRAINS, ETC. Contd...
ukfy;ksa vkfn dh tkap tkjh
WATER TESTING

ikuh dh tkap

Internal dia of drains in mm

ukyh dk Hkhrjh O;kl feeh esa


PER RUNNING METRE

18235Testing drains as specified by


fitting the pipes with water to a
head of 1.5m at the highest point
including temporarily fixing of

bends, etc. as required

N exc
1500

Exc 150 but


n exc 300

Exc 300 but


n exc 600

iz f r ehVj

vuf/kd 150 ls vf/kdo 300ls vf/kdo


18235 ukfy;ksa dh fufVZ"Vkuqlkj] tkap ds
150 feeh 300 ls vuf/kd 600 ls vuf/kd
fy;s uyksa esa 1-5 eh pkbZ rd
Rs.
Rs.
Rs.
vko';drkuqlkj vLFkkbZ eksM+ vkfn
yxkdj ikuh Hkjuk
8.40

12.10

EACH

Rs.

18236Testing manholes as specified by filling with

water

53.40

SMOKE TESTING
PER RUNNING METRE

Rs.

18237Testing soil, waste or ventilating pipes above


ground level, any height or diameter

8.40

16.70

iz R ;s d
18236 fufnZ"Vkuqlkj ikuh Hkj ds eugksyksa dh tkap djuk
/kawvk tkap
iz f r ehVj
18237 Hkwfe ry ij fdlh Hkh apkbZ ;k O;kl ij yxs iqjh"k]
voty ;k laokrh uyksa dh tkap djuk

ALTERATIONS, ADDITIONS, ETC. TO EXISTING DRAINAGE


fo|eku ty fudkl esa ifjorZu] ifjo/kZu vkfn
The rates in this table are exclusive of any excavation and bl rkfydk dh njsa fdlh Hkh izdkj dh [kqnkbZ o HkjkbZ jfgr gSa fdUrq
refilling but include for removing and replacing manhole covers esugksy ds vkoj.kksa dk gVkuk o cnyuk] o vLFkkbZ :i esa fudkl
and temporarily plugging drains as required and also risk in
can djuk rFkk dVkbZ dk tksf[ke 'kkfey gSA
cutting.
DRAINS

Internal dia of pipe in mm

EACH

uy dk Hkhrjh O;kl feeh esa

150
200
300
18238Cutting salt-glazed stoneware drain 100
pipe in position, including jointing socket Rs.
Rs.
Rs.
Rs.
end of new pipe to same with packed

spun yarn and cement mortar l:l


124.40 152.00 202.70 259.80
18239Ditto, including supplying, fixing and
jointing double socket to old pipe, and
jointing spigot end of new pipe to same
205.90 270.70 365.60 436.70

with ditto
18240Ditto, in two places, including supply of
and fixing single 'Y' junction to pipe with
loose collar to spigot end; and jointing

with spun yarn and cement mortar 1:1

417.70 576.20 875.80 1049.90

18241Cutting pipe in position and


blocking up end with cement concrete
1:2:4. type B-l for a depth of at least
58.30
30cm from the cut made

92.80 136.60 209.80

ukfy;ka
iz R ;s d
18238 igys ls yxs gq, 'kksjs ;qDr iRFkj ds ukyh
uy dks dkVuk vkSj u;s uy ds ldksVj
okys fdukjs ls mls cVs lu o 1%1 ds
lhesaV elkys ls tksM+uk
18239 mi;qDZ r] vkiwfrZ o LFkkiu rFkk f}'kk[kk ldksVj
uy esa tksMu+ s lfgr u;s uy ds xsOnkj
fdukjs dh vksj ls mls tksMu
+ k] mi;qDZ r
18240 mi;qDZ r] nks LFkkuksa esa ,d 'kk[kk okys *Y*
uy tksM]+ Ms okys fdukjs ds fy;s <hys
dkyj lfgr dh vkiwfrZ djuk o yxkuk vkSj
1%1 lhesV
a elkys o cVs lu ls tksM+ yxkuk
18241 yxs gq, uy dks dkVuk vkSj Nksj dks de
ls de 30 ls-eh- xgjkbZ rd ch&1 dh
1%2%4 dh lhesaV dahV ls can djuk

362

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
ALTERATIONS, ADDITIONS, ETC. TO EXISTING DRAINAGE Contd...
fo|eku ty fudkl esa ifjorZu] ifjo/kZu vkfn tkjh
Internal dia of pipe in mm

MANHOLES

uy dk Hkhrjh O;kl feeh esa

EACH PIPE
18242 Cutting into existing manholes for
connecting new drains, making good
to pipe and rendering, cutting out
existing benching for and forming
branch channel (1/2 round or 3/4
section) in cement concrete 1:2:4 type
B-l smooth finished, and reforming

benching as required
18243Ditto, for removing existing branch
drain, making good to walling and
rendering, cutting out branch channel,

and making good benchings

100

150

225

Rs.

Rs.

Rs.

404.20 640.50 806.00

234.60 453.20 619.00

es u gks y
iz R ;s d
18242 fo|eku esugksyksa esa ubZ ukyh tksMu+ s dVkbZ
djuk o Bhd djuk( mlds fy, fo|eku
Bh;s dh dVkbZ djuk vkSj ubZ 'kk[kk iz.kkyh
1@2 xksy ;k 3@4 nkarsnkj ch&1 Js.kh
1%2%4 dh lhesVa dahV ls 'kk[kk iz.kkyh dh
ifj"d`r laifw rZ djuk rFkk vko';drkuqlkj
Bh;s dks iqu% cukuk
18243 mi;qDZ r] fo|eku 'kk[kk ukyh dks gVkuk nhokj
dks Bhd djuk] dkVs x;s 'kk[kk iz.kkyh
Bhd djus rFkk Bh;ksa dks Bhd djus ds fy,

SETTING ONLY CAST IRON MANHOLE COVERS AND FRAMES (SUPPLIED BY M.D)
<ys yksgs ds esugksy ds vkoj.k rFkk <kaps fcBkuk vkiwfrZ ,e-Mh- }kjk
(a)

This table does not apply to covers where man holes are
measured by volume.

(b)

The rates include for preparing top of new/old brickwork,


etc., to receive covers, any digging, etc. required, and
making good surfaces disturbed.

[k

EACH

Fixing etc.

LFkkiu vkfn

18244Setting in cement mortar 1:3


and flaunching with cement
concrete 1:2:4 type B-l cast iron
manhole covers and frames,

light duty, any type and size

Taking up
or down
old covers
and frames

;g rkfydk mu vkoj.kksa ij ykxw ugha gksxh tgka esugksy


?kuRo esa ekis tkrs gSaA
bu njksa esa vkoj.k fcBkus ds fy;s u;s@iqjkus fpukbZ vkfn
dk;Z ds 'kh"kZ rS;kj djuk] fdlh izdkj dh [kqnkbZ vkfn rFkk
fopfyr lrg dks laokjuk 'kkfey gSA
Removing to
or from store

Hk.Mkj ls@esa
ykuk ys tkuk

iqjkus vkoj.k
mBkuk o yxkuk
Rs.

Rs.

Rs.

118.90

50.50

24.90

18245Ditto, medium duty ditto

142.00

55.10

31.00

18246Ditto, heavy duty ditto

165.20

55.10

41.30

iz R ;s d

18244
18244gYds deZ Hkkj o uewus o eki ds
<ys yksgs ds esugksy vkoj.kksa rFkk
<kapksa dks 1%3 ds lhesaV elkys esa
fcBkuk rFkk ch&1 Vkbi 1%2%4 dh
lhesaV dadhV ls HkjkbZ
18245
18245mi;qDZ r] e/;e deZ Hkkj] mi;qDZ r
18246
18246mi;qZDr] Hkkjh deZ Hkkj] mi;qZDr

SUB-SECTION DSANITARY APPLIANCES GENERALLY


miHkkx Mh&LoPNrk midj.k lekU;r%
(a) The rates in this sub-section are generally for fixing only, etc. of d bl miHkkx dh njsa lkekU;r;k] LoPNrk midj.k o miLdjksa
dks yxkkus ds fy, gSaA ;g njsa midj.k rFkk miLdjksa dh
sanitary appliances and fittings. These rates do not include for
vkiwfrZ ij ykxw ugha gS tks ;fn Bsdsnkj }kjk vkiwfrZ dh xbZ
supply of appliances and fittings, which if indicated to be
fn[kkbZ xbZ gS rks og Lohd`r ekud dh gksuh pkfg;sa rFkk mudk
supplied by the Contractor, shall be of approved pattern and
make and shall be paid for in addition at 'Supplied only' rates.
Hkqxrku blds vfrfjDr *dsoy vkiwfrZ* njksa ij gksxkA

363

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
SUB-SECTION DSANITARY APPLIANCES GENERALLY Contd...
miHkkx Mh LoPNrk midj.k lekU;r% tkjh
(b) Except where otherwise stated, the rates for 'fixing only'
generally include for:
(1) Removal of M.D. appliances and fittings from Store,
the care and custody of the appliances and fittings,
and the return of empties to Store (Where fittings are
supplied by M.D.).
(2) Fixing to any surface.
(3) Forming or leaving all necessary holes, cutting chases
and making good plastering, pointing, white and
colour washing. Making good of other decorations
shall be measured separately.
(4) Supplying and fixing of all subsidiary materials
required for the proper fixing of the appliances and
fittings e.g. red lead cement, cement mortar, screws,
nails, plugs, etc., but excluding brackets.
(5) Cutting out for and/or building in ends of brackets,
etc. as required.
(6) All setting, bedding, pinning in, making good,
pointing, etc, where required shall be carried out in
cement mortar 1:2 unless otherwise indicated. The joints
between stoneware and stoneware fittings, or between
cast iron and stoneware fittings shall, however, be made
in cement mortar 1:1 as described.

[k

tgka vU;Fkk fuosfnr ugha gS] *dsoy LFkkiu* dh njksa esa


lkekU;r; fuEufyf[kr 'kkfey gS%
1 ,e Mh ds Hk.Mkj ls midj.k rFkk miLdjksa dks ykuk
mudh ns[kHkky o laj{kk vkSj fjfDr;ksa dks Hk.Mkj esa
okfil djuk tgka miLdjksa dh ,e Mh }kjk vkiwfrZ gksA
2 fdlh Hkh lrg ij LFkkiuA
3 vko';d fNnzksa] dks cukuk ;k foltZu] f>fj;ksa dh
dVkbZ] vkSj iyLrj] Vhi] lQsnh] jaxkbZ dks Bhd djukA
vU; ltkoVksa dks Bhd djuk izFkd ekik tk;sxkA
4 midj.kksa o miLdjksa dks yxkus es vko';d lgk;d
lkexzh tSls yky Vkadh]] lhesaV elkyk] isp] dhysa MkVsa
vkfn fdUrq nhokjxhj ugha( dh vkiwfrZ djuk rFkk LFkkiuA
5 vko';drkuqlkj nhokjxhj vkfn rFkk@;k ds fdukjksa esa
jpuk ds fy;s dVkbZ djukA
6 lHkh fcBkbZ] fcNkbZ] yxkbZ esa Nfr dh HkjkbZ] Vhi vkfn
tgka vko';d gks 1%2 ds lhesaV elkys esa fd;k tk;sxk
tc rd fd vU;Fkk fufnZ"V u gksA iRFkj lkeku rFkk
iRFkj lkeku ds miLdj ds chp ;k <ysa yksgs o iRFkj
miLdj ds chp ds tksMk+ sa dks lhesVa ds 1%1 ds elkys ls
Hkjk tk;sxk] tSlk fd of.kZr gSA

(c) The rates 'add if fixed in repairs' include for taking down
of appliances and fittings and carriage to store or for safe
custody.

*tksM+s ;fn ejEer esa yxs gS^ dh njksa esa midj.kksa miLdjksa dks
fudkyuk vkSj Hk.Mkj esa igqp
a kuk ;k ifjj{kk esa j[kuk 'kkfey gSA

WATER CLOSETS
tyeyk/kkj
(a) The rates for 'fixing only' water closets, include for fixing
the following component parts, viz: pedestal pan (wash
down water closet) with 'P' or 'S' trap, or squatt pattern
pan with loose cast iron or Vitreous China earthenware,
'P' or 'S' trap; seat and cover for pedestal pan, foot rests for
squatt pattern; flushing cistern (high level or low level),
brackets; chain and pull or lever handle, flushing pipe of
steel tube or polyethylene including jointing to socket of
flushing rim (with and including India rubber cone joint,
if flushing rim connection is nozzle pattern) and connecting
pipe to union of flushing cistern, in let and overflow pipes
connecting only to flushing cistern, anti-syphonage pipe
joint to socket or stop per, if anti-syphonage pipe is not
required.

tyeyk/kkj dh *dsoy LFkkiu* dh njksa esa fuEu lk/kd va'kksa dks


yxkuk 'kkfey gS tSls ihfBdk ik= cgkch tyeyk/kkj *ih* ;k
*,l Qans ds lkFk ;k xksy ik= <ys yksgs ds <hys x<+s ;k dkap
phuh feh ds *ih* ;k *,l* Qan]s ihfBdk ik= dh lhV o <Ddu]
fdLe ds ik;nku /kkou Vadh mPp ry ;k fuEu ry ds
czfS dV] tathj o d"kZ.k ;k yhoj ewB( yksgs dh uyh ds ;k
ikyhFkhu /kkou uy ds dksVj ls tksMu+ k lfgr Hkkjrh; jcM+
tksM+ ds lkFk ;k jfgr A ;fn /kkou fje la;kstd uksty fdLe
dk gS rFkk /kkou Vadh dh ;qXey dks tksMu+ s okyk uy izo's k rFkk
fudkl uy dsoy /kkou ty ls tqM]s+ dksVj dks tksMu+ s okyh
jks/kd eqMh+ gqbZ uyh ;k jks/kd ;fn jks/kd uyh vko';d u gksA

(b) The rate for fixing only squatt pattern closet also includes
setting the trap and pan in lime concrete (1 lime, 2 sand or
surkhi and 5 aggretate), min. 150mm thick all round and
finished just below level of rim of pan to receive the floor
finishing (thickness as indicated).

[k

ihfBdk tyeyk/kkj ik= **dsoy yxkus dh njksa esa Qans o ik=


dks pwuk dahV 1 pwuk 2 ckyw ;k lqj[kh rFkk 5 jksMh de
ls de 150 feeh eksVkbZ esa ik= ds ry ds tjk lk uhps pkjksa
vksj yxkdj fcBkuk rkfd Q'kZ dh iwfrZ izkIr dh tk lds
dFkukuqlkj eksVkbZA

364

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
WATER CLOSETS Contd...
tyeyk/kkj tkjh
PER SEAT

18247Wash down water closet (Pedestal

pattern), complete
18248Water closet (Squatt pattern) com plete
including provision of lime concrete

bedding

Fixing
only

Add if fixed in
repairs

dsoy
yxkbZ

tksM+sa ;fn ejEer


esa yxh gks

Rs.

Rs.

475.60

285.20

715.30

332.50

18247
18247/kkscuh tyeyk/kkj ihfBdk fdLe ds lai.w kZ
18248
18248tyeyk/kkj fcBko fdLe ds laiw.kZ] pwuk
dahV vk/kkj ds izko/kku lfgr

'kkSp dkxt /kkjd


iz R ;s d
18249
18249dkap phuh feh ds 'kkSp dkxt /kkjd]
ksfe;e ;qDr ihry ds ispksa ls nhokj esa
LFkkfir
18250
18250mi;qDZ r] fdUrq ihry ;k ksfe;e eqyEek;qDr

TOILET PAPER HOLDER


EACH
18249Toilet paper holder of vitreous china
fixed to walls with chromium plated

(CP) brass screws

18250Ditto but of brass, chromium plated

15.00

8.00

10.30

6.60

Fixing only
in repairs

PARTS OF WATER CLOSETS


EACH
18251Pedestal pan and trap, including
connection to drain (or outgoing pipe) and
to flushing pipe, antisyphonage pipe, etc..

complete
18252Squatting pan including connection to trap,
and to flushing pipe, anti-syphonage pipe,

etc. complete including making good to floor


18253Ditto but including trap set in and including

con crete
18254Seat and cover for pedestal pan

dsoy yxkbZ
ejEer esa
Rs
355.70

527.00
673.00
39.10

18255High or low level fluslhing cistern (exclusive


of brackets), and connections to pipes and
fixing of chain and pull, or lever, if any
80.50
18256Foot rests of squatt pattern water closet
18257Flush pipes to pedestal pan, including all joints
18258Ditto, to squatt pattern closet including all

joints and making good to the floor

18259Cones, India rubber (nozzles of W.C. pans)


18260Joint between fluslhing pipe and socket of

W.C. pan; pre-made

79.70
75.80
83.70
35.00
34.50

izfr lhV

tyeyk/kkj ds Hkkx
iz R ;s d
18251
18251ihfBdk ik= rFkk Qans] ukyh esa la;kstu lfgr ;k
ckgj tkrs uy vkSj ckgo uy] jks/kd uy vkfn esa
lai.w kZ
18252
18252foBko ik= Qans ;k cgko uy ds la;kstu lfgr
eqM+h jks/kd uy Q'kZ dh ejEer lfgr laiw.kZ

18253
18253mi;qZDr] fdUrq dahV esa o dahV lfgr Qans
yxkuk
18254
18254ihfBdk ik= gsrq lhV o vkoj.k
18255
18255mPp ;k fuEu ry cgko okyh /kksouh Vafd;ka cSfdV
jfgr rFkk uy ls la;kstu rFkk lkady o idM+ ;k
yhoj] ;fn gks] ds lkFk LFkkfir
18256
18256fcBko tyeyk/kkj ds ik;nku
18257
18257ihfBdk ik= ds fdLe ds lHkh tksMk+ as lfgr cgko uy
18258
18258mi;qDZ r] fcBko tyeyk/kkj ds lHkh tksMk+ as ,oa Q'kZ
dh ejEer lfgr
18259
18259'kadw] ns'kh jcM+ tyeyk/kkj ik= ds uksty
18260
18260tyeyk/kkj ds cgko uy dksVj ds iwoZ fufeZr tksM+

365

SECTION 18

SECTION 18WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[k.M 18&ty viwfkZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
URINALS
ew = ik=
EACH

Fixing only in
new work or
18261 Vitreous China urinals, bowl refixing in old
type (back or corner wall type),
work
complete including providing
u;s dk;Z esa ;k
and fixing plugs, bedding urinal
against wall in cement mortar iqjkus dk;Z esa
iqu% LFkkiu
1:2, securing urinal to plugs with
and including 60mm long brass
Rs.
screws, pointing around urinal
back in cement; fixing automatic
flushing cistern with brackets,
flush pipe, grating and Union for
discharge pipe. (Exclusive of
fixing supply pipe to flushing
cistern, trap and waste pipe)
347.50

Add if fixed
in reparis

ejEer esa
LFkkiu

Rs.

190.50

PER STALL
18262 Ditto but half stall urinal

421.90

255.30

18263 Add for each additional half stall


EACH
18264 Vitreous China squatting plate

urinal

167.30

63.40
Rs.

ONLY IN REPAIRS
EACH
18265 Urinal, bowl type or half stall pattern, basin
only including connections to flushing pipe

and outgoing pipes fixed in repairs


18266 Flushing cistern and flushing pipe
(exclusive of brackets), fixed in repairs

iz R ;s d
18261 dkafpr phuh feh ds dVksjk uewuk ihB
;k nhokj dksuk uewuk ew=ik= dh O;oLFkk
djuk rFkk MkV ds lkFk 1%2 ds lhesaV
elkys esa nhokj esa 60 feeh yEcs ihry
ds isp lfgr ew=ik= ds ihNs pkjksa vksj
Vhi djds yxkuk] Lopkfyr cgko Vadh
dks czSfdV ds lkFk cgko uy] tkyh o
;qXey lfgr fudkl uy esa tksM+uk
iwfrZ uy dks /kksou Vadh Qans o vouy
ls tqM+kbZ jfgr

iz f r LVky
18262 mi;qZDr] fdUrq v/kZ [kM+h ew=/kkuh
18263 tksM+ a s izR;sd vfrfjDr v/kZ [kM+h ew=ik= gsrq
iz R ;s d
18264 dkapkf;r phuh feh ds fcBko ifdk
dh ew=/kkuh
dsoy ejEer esa

iz R ;s d
18265
18265dVksjk uewus ;k v/kZ [kM+s fdLe ds dsoy ew=/kkuh] ik=]
dks cgko uy ,oa fudkl uy ds la;kstu lfgr ejEer

esa LFkkiu
308.20
18266
18266/kksou Vadh rFkk ogko uy czSfdV jfgr ejEer esa
LFkkfir
107.10

18267 Urinal partitions slabs terminating about


40cm above floor line, fixed in repairs

18267
18267Q'kZ ry ls 40 ls-eh- ls mij rd ew=/kkuh foHkktd
ifV;k ejEer esa LFkkfir
156.60

18268 Gratings, fixed in repairs

25.30

18268
18268ejEer esa tkfy;ka LFkkfir

366

SECTION 18

SECTION 18 WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[kaM 18&ty iwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
WASH BASINS

/kks o u ik= fpyeph


(a) The rates for 'fixing only or 'fixing in repairs include
for fixing taps, waste fittings and union, plugs and chains
and connecting up to supply pipes, wastes or traps; screws,
plugs, cement mortar, red lead cement and other subsidiary
materials required for fixing.

(b) If a wash basin is fixed or re-fixed on existing brackets or


stand, half the rates of column I in this table shall be allowed.

[k

EACH
18269Wash basins, Vitreous China
(flat back or angle back type)
any size, including cutting for
and pinning in ends of
brackets or erecting stand but
exclusive of fixing of supply

and waste pipe

^dsoy LFkkiu* ;k ^ejEer esa LFkkiu* dh njksa esa uyds


yxkuk] fudkl miLdj o ;qXey] MkV o tathj vkSj iwfkZ
uy] fudkl uy ;k Qans ls la;kstu djuk] isp] MkV] lhesVa
elkyk] yky lhlk lhesaV rFkk LFkkiu esa visf{kr vU;
vko';d iwjd lkexzh] 'kkfey gSA
;fn /kksou ik= fo|eku dks"Bd ;k Vsd esa yxkuk ;k iqu%
yxkuk gS rks lwph ds izFke [kkus dh nj dk vk/kk ekU; gksxkA

Add if fixed in
repairs

dsoy
LFkkiu

tksMsa+ ;fn ejEer


esa yxh gks

Rs.

Rs.

193.60

97.90

18269
18269dkpkf;r phuh feh ds fdlh vkdkj
ds /kksou ik= likV ihB ;k dksfu;k
ihB uewus ds dVkbZ o cSzfdV ds
Nksjksa ls tksMu+ k ;k vk/kkj cukus lfgr
dks"Bd fdUrq fcuk iwfrZ o fudkl
uy

lkcqunkuh] dkap 'kSYQ


18270
18270dk p kf;r phuh feh dh cuh
lkcqunkuh nhokj esa LFkkfir

SOAP DISH, GLASS SHELF ETC.


18270Vitreous China soap tray

embedded in the wall

48.40

4.70

18271Glass shelf assembly

74.70

11.40

19.60

8.00

18272Soap dish, any type, fixed to


plugs with chromium plated

brass screws

iz R ;s d

Fixing
only

18271
18271dkap dh 'kSYQ lTtk
18272
18272fdlh uewus dh lkcqunkuh MkV esa
ksfe;e eqyE;k;qDr ihry ds isp
ls LFkkfir

SHOWER BATH FITTINGS

Luku QOokjs ds miLdj


(a) The rates for fixing mixing valves include for fixing to
walls by means of plugs and round headed brass screws.
The rate for fixing shower rose includes screwing end of
supply pipe and fixing rose thereto with red lead cement
joint or fixing to iron union.
(b) All pipe work shall be measured separately.

[k
(c) The rate 'fixing in repairs shower bath fitting in- cludes x
for disconnecting and re-fixing pipes to the extent required.

fefJr ckYo ds yxkus dh bu njksa esa nhokjksa esa xksy eqV~Bh


okys ihry ds ispksa ls MkV esa yxkuk 'kkfey gSA QCokjs dks
yxkus dh njsa mls ispksa ls iwfrZ uyksa ds fdukjksa ls tksMu+ k rFkk
uyh dks yky Vkadh ;k ;qXey }kjk tksM+uk] lfgr gSaA
reke uy dk;Z izFkd ekik tk;sxk
Luku QOokjs ds miLdjksa dks ejEer esa LFkkiu dh njksa esa
uyksa dks vyx djuk rFkk vko';d lhek rd iqu% yxkuk
'kkfey gSA

367

SECTION 18

SECTION 18 WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[kaM 18&ty iwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
SHOWER BATH FITTINGS Contd...

Luku QOokjs ds miLdj tkjh


fefJr ckYo

MIXING VALVES
EACH

Fixing only

Add if fixed
in repairs

dsoy LFkkiu

tksMsa+ ;fn ejEer


esa yxh gks

Rs.

Rs.

124.20

31.00

iz R ;s d

SHOWER ROSES

18273
18273yksgs ds uy ;k ;qXey ds rhu tksM+
lfgr nhokj ess MkV o isp yxkdj
LFkkfir

QOokjs dVks j h

EACH

iz R ;s d

18274Chromium plated shower roses


with or without swivel joints, any
size, including fixing to steel pipe

or union

18274
18274fdlh vkdkj ds ksfe;e eqyEek;qDr
Luku QOokjs] dVksfj;ka fQjdh tksM+ lfgr
;k jfgr yksgs ds uy ;k ;qXey esa
tqMk+ bZ

18273 Mixing valve including three


joints to steel pipes or unions and
plugging and screwing to walls

28.80

9.70

SINKS

gkS f n;ka

EACH

iz R ;s d
18275
18275MkV] ok'kj o fudklh ds lkFk jlksbZ ;k
iz;ksx'kkyk dh gkSfn;ka NksVh pkbZ ij
nhokjksa esa lhesaV elkys ls LFkkiu ;k
izkl cSdsV LFkkiu rFkk izR;sd 0-5 oeh
rd fudkl uy dks ;qXed ls la;kstu

18276
18276mi;qZDr] fdUrq iz R ;s d 0-5 o-eh- ls
vf/kd
18277
18277jlksbZ ;k iz;ksx'kkyk ds 1 eh eksVh
taxjks/kh bLikr dh gkSfn;ka dh MkV ok'kj
o fudkl uyksa lfgr( rFkk] NksVh apkbZ
ij nhokj esa yxkuk ;k izkl cSzfdV esa
yxkuk rFkk ;qXed dks uy ls tksM+uk]
laiw.kZ vkdkj 495 feeh x 420 feeh]]
dVksjh dk vkdkj] 410 feeh x 330 feeh
x 160 feeh dh vkiwfrZ o LFkkiu
18278
18278jlksbZ ;k iz;ksx'kkyk ds taxjks/kh bLikr
ds 1 feeh eksV]s fudkl cksMZ lfgr gkSfn;ksa
dh rFkk lkFk esa MkV ok'kj o fu"'ks"k]
nhokj esa NksVh pkbZ ij lhesaV elkys
ls fcBkbZ] ;k izkl cSzfdV o ;qXed uy
tqM+kbZ laiw.kZ vkdkj 915 feeh x 460
feeh] dVksjh dk vkdkj 410 x 330 feeh
x 160 feeh dh vkiwfrZ o LFkkiuk

18275Sinks kitchen or laboratory with


plugs, washers and wastes;
including beding in cement mortar
on to dwarf walls, or including
fixing cantilever brackets and
connecting union to waste pipe;

upto 0.5 sqm each

240.00

61.30

18276Ditto,
each

280.90

126.40

but exceeding 0.5sq. m

18277S&F sinks made of stainless steel


lmm thick kitchen or laboratory
with plugs, washers and wastes;
including bedding in cement
mortar on to dwarf wall or
including fixing cantilever brackets
and connecting union to pipe,
overall size 495mm x 420mm bowl

size 410mm x 330mm x 160mm

1886.10

18278S&F sinks with drainage board


made of stainless steel lmm thick
kitchen or laboratory with plugs,
washers and wastes; including
bedding in cement mortar to dwarf
wall or including fixing cantilever
brackets and connecting union to
pipe overall size 915mm x 460mm
bowl size 410mm x 330mm x

160mm

2414.00

Rs.

368

SECTION 18

SECTION 18 WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[kaM 18&ty iwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
MAKING GOOD DECORATIONS

ltkoVksa dks lq/kkjuk


PER FITTING

izR;sd ux

Rs.

18279Making good wall or floor tiling to match


existing (tiles supplied by M.D. or paid at

supplied only rates)

97.90

18280Ditto, terrazzo floor, dado or skirting to

match existing

124.20

18281Ditto, painted or distempered finish to

match existing

33.10

18279
18279nhokjksa ;k Vk;yksa ds Q'kZ dks fo|eku ls feyku esa
Bhd djuk Vk;ysa dh ,e Mh }kjk vkiwfrZ ;k dsoy
vkiwfrZ njksa ij Hkqxrku
18280
18280mi;qDZ r] rSjktks]a Q'kZ] MkMks ;k xksVu dk fo|eku ls
feyku
18281
18281mi;qDZ r] jaxh gqbZ ;k fMLVSEij dh gqbZ laifw kZ fo|eku
ls feyku

MATERIALS (Supplied only)

lkexzh dsoy vkiwfrZ


EACH
18282 Rubber or fibre board
gaskets for flanged

joints

Bore of pipe in mm

iz R ;s d

uy fNnz feeh esa

80
Rs.

100
Rs.

150
Rs.

200
Rs.

250
Rs.

300
Rs.

14.10

23.50

28.20

34.10

49.30

64.60

18282
18282dksVnkj tksMk+ as ds fy, jcM+
;k js'ks xkaB xqPNs

GALVANISED STEEL WATER TUBING

tLrh yksgs dh ty ufy;ka


d uyh dh ;g njsa izR;sd yEcu uy esa yxh ,d dksVj
lfgr gSaA
[k uyh dh eki uyh ds ,d fdukjs ls nwljs fdukjs ij dlh
dksVj ds dksus rd yh tk;sxhA

(a) The rates for tube include for one plain socket to each
length.
(b) The length of each tube shall be measured from end of
tube to end of socket which shall be fully screwed on.

PER RUNNING
Bore of pipe in mm
uy fNnz
METRE
15
20
25
32
40
18283 Galvanised steel Rs. Rs. Rs.
Rs.
Rs.
tubes, light grade
78.70 106.90 172.70 229.10 264.40
18284Ditto, medium
83.40 116.30 184.50 249.10 290.20
grade

feeh esa

iz f r ehVj

50
Rs.

80
Rs.

100
Rs.

340.70

481.70

663.90 895.30

366.60

546.40

728.50 960.00

POLYETHYLENE
Bore of pipe in mm uy fNnz feeh esa
AND
15
20
25
32
40
50
UNPLASTICISED PVC PIPES
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
18285Low density polyethylene
(LDPE) pipes of pressure rating
25.80 30.50 39.90 45.80 84.60 96.30
6 kgf/sq. cm
18286 High density polyethylene
(HDPE) pipes of pressure

rating 6 kgf/sq. cm
30.50 37.60 49.30 54.00 84.60 98.70
18287Unplasticized PVC pipes of
pressure rating 10 kgf/sq. cm
28.20 31.73 49.30 57.60 67.00 104.60

150
Rs.

18283
18283tLrh yksgs dh fuEu
nko dh ufy;ka
18284iwoksZDr] e/; nko
18284

iksyhFkhyhu o vlq?kV; ihohlh uy


18285
18285fuEu ?kuRo iks y hFkhyhu uy
,yMhihbZ o nko nj 6 fdxzke
QkslZ@oxZ lseh
18286 mPp ?kuRo iks y hFkhyhu uy
,pihMhbZ i nkc 6 fdxzkQ@oxZ
lseh
18287
18287vlq?kV; ihohlh nko nj ij 10 fd
xzkQ@oxZ lseh ds uy

369

SECTION 18

SECTION 18 WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[kaM 18&ty iwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
MATERIALS (Supplied only) Contd.

lkexzh dsoy vkiwfrZ tkjh


izofyr dahV uy

REINFORCED
CONCRETE PIPES
PER RUNNING
METRE

uy fNnz feeh esa

Bore of pipe in mm
80
Rs.

100
Rs.

150
Rs.

200
Rs.

250
Rs.

300
Rs.

450
Rs.

iz f r ehVj
600
Rs.

18288 Reinforced concrete


pipes, class NP 2 with
one collar per length
123.40 158.60 199.70 240.90 295.50 373.60 499.40 952.00
of pipe
18289Ditto, class NP 3
183.30 196.23 239.70 399.50 446.50 642.73 1096.28 1525.15

18288
18288izofyr dahV uy ,d
dkyj izfr yEcu lfgr
,uih&2 Js.kh ds
18289
18289mi;qZDr( ,uih&3 Js.kh

MISCELLANEOUS

fefJr
PER KILOGRAM

izfr fdyksxzke

Rs.

18290 Pig lead

115.10

18290 nzO; Vkadh

18291 Lead wool

96.30

18291 u Vkadh

18292 Red or white lead cement

105.70

18292 yky ;k lQsn lhesaV Vkadh

18293 Spun yarn

61.10

18293 cVk gqvk lu

WASHERS

cklZ y

For valves of sizes

ckYo ds uki ds fy;s

PER 10 NOS.

izfr 10 u-

20mm and Exc 20mm but n Exc 32mm but


under
exc 32mm
n exc 50mm

20 feeh vkSj 20 eheh ls vf/kd


32 feeh ls
de
ijUrq 32 feeh
vf/kd ijUrq 50
ls vuf/kd
feeh ls vuf/kd
18294India rubber washers for

pillar taps etc.

Rs.
2.50

Rs.
3.50

Rs.
8.70

18295Fibre washers for hot water

taps

2.90

5.20

10.90

18294 [kEHks uy vkfn ds fy, ns'kh jcM+


cklZy
18295 xeZ ikuh ds uyksa ds fy;s js'ks ds
cklZy

370

SECTION 18

SECTION 18 WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[kaM 18&ty iwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
MATERIALS (Supplied only)Contd.

lkexzh dsoy vkiwfrZ tkjh


EACH

Rs.

18296Cones for W.Cs., India rubber with

canvas backing

14.80

iz R ;s d
18296
18296eyk/kkj ds ns'kh jcM+ dsuokl ds 'kadw

'kksjs ;qDr iRFkj ds fudkl uy

SALT-GLAZED, STONEWARE
DRAIN PIPES

18297 Salt glazed stoneware drain

pipes, grade A

iz f r ehVj

Internal dia in min

PER RUNNING
METRE

var% O;k; feeh esa

80
Rs.
99.90

100
Rs.
108.10

150
Rs.
193.90

200
Rs.
232.60

18297
18297, Js.kh ds 'kksjs ;qDr iRFkj ds
fudkl uy

DRAIN PIPE FITTINGS

fudkl uy ds miLdj

EACH

iz R ;s d

18298Salt glazed stoneware bends


and taper bends, any radius

18298
18298'kksjk ;qDr iRFkj ds fdlh O;kl ds
eksM+ o eksM+ iV~Vh

18299
18299mi;qZDr] ,d 'kk[kk okys Y laxe]
mi;qZDr
18300
18300mi;qZDr] f} 'kk[kk okys Y laxe]
mi;qZDr

52.90

18299Ditto, single Y junctions,

ditto
119.80
18300Ditto, double Y junctions,
125.70

ditto

79.90

105.70

141.00

135.10

172.70

232.60

132.80

164.50

211.50

CHANNEL CONNECTIONS

uyh la;kstd
iz R ;s d
18301
18301Qan]s vojks/kh] ifjn'kZu Hkqtk;sa lknk
fdLe ds jks/kd o tkap Hkqtk tLrh
yksgs ds izkl tksM+ esa] LFkkfir ;k
vU; Lohd`r uewuk lkFk esa tLrh
yksgs ds yhoj] tathj o gqd

EACH
18301Traps, intercepting, the
inspection arms fitted with
plain pattern stopper and
inspection arm fitted with
galvanised iron bayonet joint
(or other approved pattern)
with galvanised iron lever,
galvanised iron chain, ring
152.70

and hook

198.60

LoPNrk miLdj

SANITARY FITTINGS
EACH

Rs.

18302Vitreous China wash down


water closet pan (pedestal
pattern), white (excluding
fixing bolts, flushing cistern

and flush pipe)


18303Vitreous China, semi-pedestal
pattern (Anglo-Indian Type)

(ditto)

662.70
1645.00

iz R ;s d
18302
18302dkapkf;r phuh feh ds cgkoh
tyeyk/kkj ihfBdk uewuk lQsn
LFkkiu dkoys] cgko Vadh] o cgko
uy jfgr
18303
18303dkapkf;r phuh feh ds v/kZihfBdk
uewus ds vakxy&Hkkjrh; fdLe
mi;qZDr

371

SECTION 18

SECTION 18 WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[kaM 18&ty iwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
MATERIALS (Supplied only)Contd.

lkexzh dsoy vkiwfrZ tkjh


SANITARY FITTINGSContd.

LoPNrk miLdj tkjh


EACH

Rs.

18304Vitreous China squatting pan of pattern


long pan, size 580 mm white with P or
S trap, front or back inlet and foot rests,
any pattern (excluding flushing cistern

and flush pipe)

499.40

18305Ditto but size 630mm

18306vitreous China squatting pan, Orissa


pattern, size 580 x 440 mm white, with
integral foot rests (excluding flushing

cistern and flush pipe)

546.40

18307Ditto but size of 630 x 450 mm

1081.00

18308Ditto but size of 680 x 470 mm

1204.40

18309Vitreous China Urinal, Half stall type,


white (excluding flushing cistern, flush

pipe and waste pipe)


18310Vitreous China bowl urinal flat back, size
of 465 x 355 x 265 mm white (minimum),
with grating and union for discharge pipe
(excluding flushing cistern, flush pipe and

waste pipe)
18311Ditto but angle back of size 430 x 370 x

340 mm (minimum)
1831210 litres, cast iron, valveless. syphonic
action type, flushing cistern, high level,
with inlet, ball valve, float, chain and pull,

and brackets
1831312.5 litres, ditto

18314Vitreous China valveless,


syphonic action type, 10 litres
flushing cistern, low level, 10 yhVj
Rs.
white, with inlet, ball valve,
float and handle including
brackets

1496.90
18315Ditto but flushing cistern of
pressed steel, enamelled

white
18316 PVC valveless, syphonic
action type, flushing cistern,
low level, white, with inlet,
ball valve, float and handle
including brackets

983.50

1045.70

440.60
467.60

1028.10
1089.20

iz R ;s d
18304
18304dkapkf;r phuh feh ds fcBko ik= yEcs ik=
580 feeh vkdkj ds lQsn ^ih* ;k ^,l* Qans
lkeus ihNs izos'k rFkk ik;nku] dksbZ uewuk lfgr
cgko Vadh o cgko uy jfgr
18305
18305mi;qZDr] fdUrq vkdkj 630 feeh
18306
18306dkapkf;r phuh feh ds fcBko ik= *mM+hlk* uewus
o vkdkj 580 x 440 feeh lQsn] vUn:uh ik;nku
lfgr cgko Vadh o cgko uy jfgr
18307
18307mi;qZDr] fdUrq vkdkj 630 x 450 feeh
18308
18308mi;qZDr] fdUrq] vkdkj 680 x 470 feeh
18309dkapkf;r phuh feh eq=ikr v/kZ LVko lQsn
18309
ogko Vadh] cgkoh uy o fudkl uy jfgr
18310
18310dkapkf;r phuh feh ds] likV ihB ew=ik=] 465
x 355 x 265 feeh ds lQsn U;wure fudkl ds
fy, tkyh o ldksVj lfgr cgko Vadh] cgko
uy o fudkl uy jfgr
18311
18311mi;qZDr] fdUrq dksfu;k ihB ds 430 x 370 x 340
feeh U;wure
18312
18312<ys yksgs ds 10 yhVj ds okYo jfgr eqM+h }kj o
cgko uyh Vkbi dh cgko Vadh ps vk/kkj izo's k
cky ckYo] pyk;eku tathj o idM+ rFkk nhokjxhj
lfgr
18313
18313mi;qZDr] 12-5 yhVj

12.5 litres

15 litres

Rs.

Rs.

1645.00

1880.00

1407.60

1480.50

1645.00

734.40

12-5 yhVj

15 yhVj

18314
18314dkapkf;r phuh feh dh ckYo
jfgr eqM+h cgko uyh Vkbi dh
cgko Vadh uhps vk/kkj dh lQsn
rFkk izos'k }kj xksyk ckYo]
pyk;eku] gRFkk vkSj
nhokjxhj lfgr
18315
18315mi;qZDr] fdUrq laihfMr yksgs dh
lQsn jksxu dh gqbZ cgko Vadh
18316

372

SECTION 18

SECTION 18 WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[kaM 18&ty iwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
MATERIALS (Supplied only)Contd.

lkexzh dsoy vkiwfrZ tkjh


EACH
18317 5 litres cast iron automatic flushing cistern,

including brackets

364.20

1831810 litres, ditto

411.20

1831915 litres, ditto

481.70

18320Mild steel tube flush pipe, 32mm dia, for high

level cistern

252.60

18321Brass chromium plated shower rose

125mm size

205.60

18322Flush pipe of polyethylene of low or high


density or PVC. 32 mm dia, for low level

cistern
18323Flush pipe of chromium plated brass tube,

32mm dia, for low level cisterns

18324 Toilet paper holder, vitreous China,

box type

iz R ;s d
18317
18317<ys yksgs dh 5 yhVj dh dks"Bd lfgr Lopy
cgko Vadh
18318
18318mi;qZDr] 10 yhVj
18319
18319mi;qZDr] 15 yhVj
18320
18320uje yksgs ds cgko uy 32 feeh O;kl dh vk/kkj
okyh Vadh ds fy,
18321
18321125 feeh vkdkj ksfe;e ;qDr ihry ds QCokjk
dVksjh
18322
18322fuEu vk/kkj dh Vadh gsrq 32 feeh O;kl ds fuEu ;k
mPp ?kuRo ds ikyhFkhu cgko uy

Rs.

64.60

18323
18323fuEu vk/kkj dh Vadh gsrq 32 feeh O;kl ds ksfe;e
eqyEek;qDr ihry ds cgko uy

381.90

White

Coloured

lQsn

jaxhu

Rs.

Rs.

205.60

317.20

18324
18324dkapkf;r phuh ds cDlsuqek eq=/kkuh dkxt
MCcs

Rs.
18325Vitreous China Urinal, full stall type, white
(excluding flushing cistern, flush pipe and
2820.00
waste pipe)
18326Plastic water closet seat, black, closed pattern with
flat bottom, and cover and mild steel chromium
481.70
plated or aluminised hinging device

18325
18325dkapkf;r phuh feh ds iw.kZ <kih fdLe ds ew=ik=
cgko Vadh] cgko uy o fudkl uy jfgr
18326tyeyk/kkj ds fy,] dkyh canuqek ij likV ry dh
18326
lhV rFkk vkoj.k vkSj uje yksgs dk ksfe;e
eqyEek;qDr ;k vYeksfu;e ds tqM+k lk/ku
18327
18327mi;q
ZDr] fdUrq vUrjh; ry
490.00
18327Ditto but with recessed bottom
18328White glazed fine clay sink size
18328
18328gkSnh lQsn tLrh mre feh dh 600 x 450 x 200
2350.00
600x450x200mm
feeh vkdkj okyh
3172.5 18329
18329Ditto size 750x450x250mm
18329mi;qZDr] 750 x 450 x 250 feeh
18330
18330/kksou ik= dkapkf;r phuh feh ds lQsn likV ihB
18330Vitreous Cliina wash basin, wliile, flat back, size
580x450irun (for Hospilal use) excluding taps,
okys 580 x 450feeh vkdkj gLirky iz;ksx gsrq uy]
waste, chain and plug and porcelain stopper
tathj o jksd rFkk phuh feh dh jksd jfgr fdUrq
763.70
but including brackets
dks"Bd lfgr
18331
18331Vitreous China wash basin, white, flat back, size
18331/kkou ik= dkapkf;r phuh feh ds lQsn] likV ihB
630x450mm excluding ditto but including
okys] 630 x 450 feeh uki okys jfgr mi;qZDr
brackets
18332Ditto but size 550x400mm

18333Ditto but size 450x300mm


18334Vitreous Cliina wash basin, angle back, size
600x480mm white, excluding taps, waste,
chain and plug and porcelain stopper but

including brackets

834.20
740.10
820.10

963.50

18332
18332mi;qZDr] fdUrq 550 x 400 feeh vkdkj
18333
18333mi;qZDr] fdUrq 450 x 300 feeh vkdkj
18334
18334/kksou ik= dkapkf;r phuh feh ds] dksfu;k ihB okys(
vkdkj 600 x 480 feeh lQsn] Vksfa V;k] fudkl] tathj
o MVs vkSj phuh feh ds jksd jfgr fdUrq dks"Bd
lfgr

373

SECTION 18

SECTION 18 WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[kaM 18&ty iwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
MATERIALS (Supplied only)Contd.

lkexzh dsoy vkiwfrZ tkjh


Rs.

EACH
18335 Dilto, size 400 x 400mm

18336 Add to items 2977 to 2981 for supply of

pedestal
18337 600mmx450mm bevelled edge mirror of
selected quality glass, mounted on 6mm
thick AC building board or commercial
plywood and fixed to wooden plugs with
chromium plated brass screws and cup

washers
18338 Soap dish, vitreous China white, approximate size 160x 160x90mm
18339 Sheet glass shelf assembly consisting of
5.5mm thick sheet glass shelf 12cm wide
with chromium plated bracket guard and

railing 60cm long


18340 Ditto with aluminium alloy brackets and

guard rail

810.70
834.20

593.40
115.10

223.20
158.60

18341 White vitreous china laboratory sink size

450x300x150
1116.20

18342 Ditto-but size 600x450x200mm


18343 Stainless steel sink, 1.00mm thick for
kitchen or laboratory, with plug, waste
pipe, washers, including cantilever cast
iron brackets, connecting union etc.,
overall size 495mm x 420mm with bowl

size 410mm x 330mm x 160mm


18344 Stainless steel sink with draining board,
made out of 1.00mm thick sheet for kitchen
or laboratory with plug, washers waste
pipe, cast iron cantilever brackets,
connecting union overall size
915mmx460mm with bowl size 410mm x

330mm x 160mm
18345 Vitreous china squatting plate urinal,
white (excluding flushing cistern, flush

pipe and waste pipe)


18346 Vitreous china urinal partition white of

size 310x700 mm.

2350.00

1645.00

3055.00

399.50
481.70

iz R ;s d
18335 mi;qZDr] 400 x 400 feeh vkdkj
18336 tksM+sa en 2977 ls 2981 esa ihfBdk vkiwfrZ gsrq
18337 niZ.k vuqeksfnr dksfV ds dkap ds <kyw fdukjs okys
600 x 450 feeh 6 fee eksVh ,sLosLVl pknj ds
r[rs ;k O;olkf;d vkLrj.k esa ksfe;e eqyEek;qDr
ihry ds isp o ok'kj ls ydM+h ds xqVdksa ij
LFkkfir
18338 lkcqunkuh dkapkf;r phuh feh dh] 160 x 160 x
90 feeh laHkkfor vkdkj
18339 'kSYQ dkap dh 5-5 feeh eksVh pknj ls 12 lsehpkSMh+] ksfe;e eqyEek;qDr dks"Bd o 60 lseh yEch jksd NM+ lfgr
18340 mi;qZDr] ,yeksfu;e /kkrq dksfu;k dks"Bd o jksd
NM+ lfgr
18341 iz;ksx'kkyk o jlksbZ dh gkSfn;ka dkapkf;r phuh feh
dh lQsn] 450 x 300 x 150 vkdkj
18342 mi;qZDr fdUrq 600 x 450 x 200 feeh vkdkj
18343 LVsuySl LVhy gkSnh] 1 feeh eksVh jlksbZ ;k iz;ksx'kkyk
ds fy,] MkV fudkl uy ok'kj] izkl yhoj] <ys
yksgs ds cSzfdV] la;kstd ;qXed vkfn laiw.kZ vkdkj
495 x 420 feeh] p"kd vkdkj 410 x 330 x 160
feeh
18344 LVsuySl LVhy dh gkSnh lkFk esa fudk'k cksMZ tks
1-00 feeh eksVh LVhy ls cus jlksbZ ;k iz;ksx'kkyk
ds fy;s] MkV] ok'kj] fudkl uy] <ys yksgs ds izkl
cSd
z Vs la;kstd ;qXed lai.w kZ vkdkj 915 feeh x 410
feeh] p"kd vkdkj 410 x 330 x 160 feeh

18345 dkpkaf;r phuh feh dh mBkoh IysV ew=ikr] lQsn


ogkch uy o fudkl uy jfgr
18346 dkpkaf;r phuh dh lQsn ew=ikr nhokj vkdkj 310 x
700 fe eh

374

SECTION 18

SECTION 18 WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES


[kaM 18&ty iwfrZ] uy tqM+kbZ] ty fudklh rFkk LoPNrk midj.k
MATERIALS (Supplied only)Contd.

lkexzh dsoy vkiwfrZ tkjh


Capacity in Litres

{kerk fyVj esa


18347Plastic
water
approved quality

200

500

750

1000

2000

Rs.

Rs.

Rs.

Rs.

Rs.

tank,
1294.80 2590.90

PER RUNNING METRE


18348PVC (SWR) pipes, single socketed, in any

length, with rubber rings 75mm dia


18349PVC (SWR) pipes, single socketed, in any

length , with rubber rings 110mm dia


18350PVC (SWR) pipes, double socketed, in any

length, with rubber rings 75mm dia


18351PVC (SWR) pipes, double socketed, in any

length, with rubber rings 110mm dia

3886.10

5757.50 11515.00

iz f r ehVj

Rs.
115.90
211.80
176.20
225.60

18347
18347IykfLVd uy Vadh Lohd`r dksfV

18348
18348ihohlh lhoj uy] ,dy ldksfVr] fdlh yEckbZ esa
75 feeh O;kl ds NYys lfgr
18349
18349ihohlh lhoj uy] ,dy ldksfVr fdlh yEckbZ esa]
lkFk 110 feeh O;kl jcM+ NYyk
18350
18350ihohlh lhoj uy] nksgjs ldksfVr] fdlh yEckbZ esa
75 feeh jcM+ NYys ds lkFk
18351
18351ihohlh lhoj uy] nksgjs ldksfVr] fdlh yEckbZ esa
110 feeh jcM+ NYys ds lkFk
iz f r fyVj

PER LITRE

18352 Rubber lubricant for PVC (SWR) pipes


18352A Solvent cement for PVC (SWR) pipes

176.20
139.80

18352 jcM+ rsfyr] ihohlh lhoj uy ds fy,


18352, foyk;d lhesaV] ihohlh lhoj uyksa ds fy;s

STEEL WATER TUBING Contd...


yksgs dh ty ufydk tkjh
ITEM NO 18353 TO ITEM NO 18371 : ALTERNATE TO STEEL WATER TUBING SECTION 18 PAGE 331 TO 337
" CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPES & FITTINGS FOR HOT & COLD WATER SUPPLY"
REFER DESCRIPTION BELOW & ITEMS NOS 18353 TO ITEM NO 18371 ON PAGE NO XVI OF THIS BOOK.
CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPES & FITTINGS FOR HOT & COLD WATER SUPPLY :
(A)
(B)
(C)
(D)
(E)

(F)

(G)
(H)
(J)

CPVC pipes as per IS:15778 are produced in two different Standard Dimensional ratios SDR 11 & SDR 13.5.
Pressure bearing capacity of SDR 11pipes @23C is 28.12kg/cm & at @82C 7.03kg/cm and SDR 13.5 @23C
is 22.5kg/cm & at @82C 5.60 kg/cm. CPVC fittings up to 50 mm are all SDR 11.
CPVC pipes above 50mm are as per ASTM F 441 in Schedule 80 & Schedule 40. CPVC fittings above 50mm are
Schedule 80 only.
All pipes & fittings of CPVC are UV Stable, leak proof, tough, rigid and suitable for internal and external water
supply applications.
One step CPVC yellow solvent cement to be used for pipe & fittings up to 50 mm and 2 step CPVC Solvent cement
comprising of 1st step CPVC Primer and 2nd step CPVC solvent cement to be used on pipes & fittings above 50mm.
Plain CPVC fittings mean fittings which do not have any metal component and is jointed with CPVC solvent
cement only (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc). Special fittings
include CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass
adaptor etc), Unions, Ball valves, Flange and tank adaptor.
The rate below includes all plain CPVC fittings and pipe cutting fixing with CPVC solvent cement and testing.
The rate do not includes for special fittings [CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass
adaptor, Female threaded brass adaptor etc), Unions, Ball valves, Flange and tank adaptor]. These special
fittings shall be paid extra under relevant item of this schedule.
CPVC pipes and fitting shall be FlowGuard / approved makes only.
The dimensions mentioned are as per industry nomenclature and for exact dimensions of the pipe Outer
Diameter, Inner Diameter and wall thickness consult the relevant above stated codes.
The rates do not include for cutting chases in wall, floors etc and their making good in case of concealed pipe
work and earth work in case of pipes laid in trenches.

Matter Continued on Page. XVI

375

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
SECTION 19
ELECTRICAL WORK
[k.M 19 fo|qr dk;Z
SUB-SECTION & A EXTERNAL WORK
mi[k.M&d ckgjh dk;Z
ELECTRICAL POLES AND STRUTS
fctyh ds [kEHks rFkk LrEHk
(a) The rates include staying the poles in a truly vertical
position till the foundations are properly set.

(b) Excavation, foundation concrete, presenative treatment, etc.


will be measured separately under the appropriate sections.
Painting to steel tubular poles (inside and outside) is
however included in the rates of steel tubular poles.

[k

(c) The rates for poles shall also apply to struts when poles of
the same size are used as struts.
(d) Rates for steel tubular poles also include provision of finial
and cast iron base plate fixed to poles.

(e) The rates also include drilling of holes in steel tubular


poles and provision of precast holes in PCC poles for fixing
'D' iron, clamps and hooks for continuous G.I. earth wire
etc. to the required size and number.

?k

bu njksa esa [kaHks dks lgh lh/kh fLFkfr esa Fkkesa j[kuk lekfgr
gS tc rd fd uhao iw.kZ:i ls iDdh ugha gks tkrhA
Hkwfe dh [kqnkbZ] uhao dahV cpko mipkj vkfn] mi;qDr
[kaMksa ds vUrxZr] izFkd ekis tk;sx
a As bLikr ukyhnkj [kaHkksa ij
vUnj o ckgj jaxkbZ dk;Z rFkkfi yksgs ds uyhnkj [kaHkksa ds
dk;Z dh njksa esa gh lfUufgr gSaA
[kaHks dh njsa LrEHkksa ij Hkh ykxw gksx
a h tc leku eki ds [kaHkksa
dk iz;ksx lLrEHkksa ds leku gksA
yksgs ds uyhnkj [kaHkks dh njksa esa ij ds dy'k rFkk yksgs
dh <yh ry if;ksa dh O;oLFkk djuk ,oa mUgsa [kaHks esa
yxkuk Hkh fufgr gSA
yksgs ds uyhnkj [kaHks esa ojes ls Nsn djuk vkSj tLrh yksgs
ds Hkwfe xr rkj dh fujUrjrk cuk;s j[kus ds fy, izofyr
lhesaV dahVds [kaHks esa ^Mh* bLikr f'kdts o gqd yxkus ds
fy, izofyr Nsn dh O;oLFkk djuk Hkh 'kkfey gSA

WOOD POLES
ydM+h ds [kEHks
EACH
19001Wood pole, normal height 8 metres,
ground line position from butt end
1.5 metres and minimum
circumference at ground line
position from 66cm to 78cm.
19002Wood pole, normal height 9 metres,
ground line position from butt end
1.5 metres and minimum
circumference at ground line
position from 70cm to 82cm.
19003Wood pole, normal height 10 metres,
ground line position from butt end
1.8 metres and minimum
circumference at ground line
position from 73cm to 84cm.
19004Wood pole, normal height 12 metres,
ground line position from butt end
1.8 metres and minimum
circumference at ground line
position from 78cm to 92cm.

M&L

Fixing only

lkexzh ,ao Je

dsoy LFkkiu

Rs.

Rs.
115.00

165.00

195.00

231.00

iz R ;s d
19001
19001ydM+h ds [kaHks] ftudh lkekU; pkbZ 8
ehVj gks vksj daqMs ds Nksj ls Hkwfe js[kk
fLFkfr 1-5 ehVj rFkk Hkwfe js[kk fLFkfr ij
U;wure ?ksjk 66 ls- fe- ls 78 ls- fe19002
19002ydM+h ds [akHks] lkekU; pkbZ 9 eh- gks
vkSj dqM
a s ds Nksj ls Hkwfe js[kk fLFkfr 1%5 eh]
rFkk Hkwfe js[kk fLFkfr ij U;wure ?ksjk 70
lseh ls 82 lseh
19003
19003ydM+h ds [kaHks] lkekU; pkbZ 10 eh vkSj
dqM
a s ds Nksj ls Hkwfe js[kk fLFkfr 1-8 eh rFkk
Hkwfe js[kk fLFkfr ij U;wure ?ksjk 73 lseh
ls 84 lseh
19004
19004ydM+h ds [kaHks] lkekU; pkbZ 12 eh vkSj
dqM
a as ds Nksj ls Hkwfe js[kk fLFkfr 1-8 eh rFkk
Hkwfe js[kk fLFkfr ij U;wure ?ksjk 78 lseh
ls 92 lseh

376

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
PRE-STRESSED CONCRETE POLES
iwoZ izfrcfyr dahV[kaHks
M&L

EACH

Rs.

Rs.

5437.00

213.00

iz R ;s d
19005
19005iwoZ izfrcfyr dahV[kaHks] Js.kh 9 ds
11-0 eh yEcs] f'k[kj ij 152152 feeh
rFkk iSanh ij 152260 feeh

183.00

19006
19006iwoZ izfrcfyr dahV[kaHks] Js.kh 10 ds 9-0
eh yEcs] f'k[kj ij 102172 feeh rFkk
iSanh ij 102279 feeh

207.00

19007
19007iwoZ izfrcfyr dahV[kaHks] Js.kh 10 ds 9-0
eh yEcs] f'k[kj ij 102152 feeh rFkk
iSanh ij 102289 feeh

179.00

19008
19008iwoZ izfrcfyr dahV[kaHks] Js.kh 11 ds 7-5
eh yEcs] f'k[kj ij 102152 feeh rFkk
iSanh ij 102281 feeh

160.00

19009
19009iwoZ izfrcfyr dahV[kaHks] Js.kh 11 ds 7-5
eh yEcs] f'k[kj ij 102120 feeh rFkk
iSanh ij 102229 feeh

19005Prestressed concrete pole, 11.0 lkexzh ,ao Je


metres long. 152mm x 152mm at top
and 152mm x 260mm at bottom,

class 9
19006Prestressed concrete pole, 9.0 metres
long, 102mm x 172mm at top
and l2mm x 279mm at bottom,

class 10
19007Prestressed concrete pole, 9.0 metres
long, 102mm x 152mm at top
and 102mm x 289mm at bottom,

class 10
19008Prestressed concrete pole, 7.5 metres
long, 102mm x 152mm at top and
102mm x 281mm at bottom,

class 11
19009Prestressed concrete pole, 7.5 metres
long, 102mm x 120mm at top
and 102mm x 229mm at bottom,

class 11

Fixing only

3912.00

3707.00

2699.00

2541.00

dsoy LFkkiu

STEEL TUBULAR POLES


yksgs ds uyhnkj [kaHks
EACH
19010Steel tubular swaged poles complete
with cast iron base plate, finial taper
plug, bolts, nuts & screws as
specified type 410 SP-22 (8.5

metres long)
19011Ditto, type 410 SP-31 (9.00 metres

long)
19012Ditto, type 410 SP-37 (9.5 metres

long)
19013Ditto type 410 SP-44 (10.0 metres

long)
19014Ditto, type 410 SP-55 (11.0 metres

long)
19015Ditto, type 410 SP-64 (12.0 metres

long)

M&L

Fixing only

lkexzh ,ao Je

dsoy LFkkiu

Rs.

Rs.

5091.74

121.50

5318.99

137.24

5559.51

166.26

5893.33

168.73

7652.78

184.48

9788.22

200.22

iz R ;s d
19010
19010bLikr ds uyhnkj <.ok [kaHks 8-5 eh yEcs
fufnZ"V 410 ,lih&22 uewuk <ys yksgs dh
vk/kkj iV~Vh] fufnZf"Vr f'k[kj ca/kd xs]
dkoys] fnCckjh o isp lfgr
19011
19011mi;qDZ r] uewuk 410 ,lih&31 9-0 eh yEcs
19012
19012mi;qDZ r] uewuk 410 ,lih&37 9-5 eh yEcs
19013
19013mi;qDZ r] uewuk 410 ,lih&44 10-0 eh yEcs
19014
19014mi;qDZ r] uewuk 410 ,lih&55 11-0 eh yEcs
19015
19015mi;qDZ r] uewuk 410 ,lih&64 12-0 eh yEcs

377

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
CROSS ARMS
dSaph Hkwtk
PER QUINTAL

M&L

19016Cross arms, bracings, supports, lkexzh ,ao Je


clamps and back plates fabricated
from structural steel sections
including nuts, bolts, washers,
welding, bending cold or hot,
drilling holes for bolts, in any shape
or size as indicated or directed and
inclusive of one primer coat, one
under coat and one finishing coat of

paint

Fixing only

dsoy LFkkiu

Rs.

Rs.

8584.00

932

iz f r fDoa V y
19016
19016dSp
a h Hkqtk] if;ka ca/ku] vkyac] f'kdats o
bekjrh bLikr [kaM ls fojfpr jksd IysV]
dkoys] fnofj;ka fdlh :i ;k vkdkj dh]
tSlk Hkh lwfpr ;k funsZf'kr gks vkSj jksxu
dh ,d vLrj.k rg ij ,d vLrjh o ,d
iwfrZ ijr yxkus lfgr

INSULATORS
fo|q r jks / kd
EACH
19017Pin type, porcelain, vitreous, white,
brown or green insulator including
one galvanised mild steel spindle,
two galvanised iron washers and
one galvanised iron nut, 50mm
height, 65mm dia for 550 volts

grade
19018Ditto, 100mm height, 65mm dia for

1100 volts grade


19019Ditto, 100mm height, 100mm dia for

3300 volts grade


19020Ditto, 150mm height, 135mm dia for

6600 volts grade


19021Ditto, 150mm height, 150mm dia for

11000 volts grade

M&L

Fixing only

lkexzh ,ao Je

dsoy LFkkiu

Rs.

Rs.

65.00

14.00

73.00

14.00

97.00

14.00

116.00

14.00

190.00

14.00

Shackle Type, Porcelain, vitreous, white, brown or green


insulator including galvanised mild steel straps, washers,
insulator bolts, washers and nuts, as under:

iz R ;s d
19017
19017fiu leku dkapf;r phuh feh ds bLikr
fo|qrjks/kd] lQsn] Hkwjs ;k gjs] ,d uje
bLikr dh tLrh rdyh] nks tLrh bLikr
ok'kj o ,d tLrh bLikr f<cjh] 50 feehapkbZ] 550 oksYV oxZ ds fy;s 65 feeh
O;kl lfgr
19018
19018mi;qZDr] 1100 oksYV oxZ ds fy,] 65 feeh
O;kl] 100 feeh] ps
19019
19019mi;qZDr] 3300 oksYV oxZ ds fy,] 100
feeh O;kl] 100 feeh ps
19020
19020mi;qZDr] 6600 oksYV oxZ ds fy,] 135
feeh O;kl] 150 feeh ps
19021
19021mi;qZDr] 11000 oksYV oxZ ds fy,] 150
feeh O;kl] 150 feeh ps

dqaMk leku] dkapkf;r phuh feh ds lQsn Hkwjs ;k gjs fo|qr


jks/kd] tLrh uje bLikr ih] ok'kj jks/kd dkoyk o f<cjh
fuEukuqlkj%%&

378

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
INSULATORS Cont...
fo|qrjks/kd tkjh

Working
pressure
in volts

Size

Galvanised steel fittings

M&L

vkdkj

tLRkh bLikr miLdj

lkexzh ,oa
Je

Height in Max. dia in


mm
mm

lf+; ncko mapkbZ feeh vf/kdre


oksYV esa
esa
O;kl feeh esa
19022
19023
19024
19025
19026
19027

Fixing
only

dsoy
LFkkiu

Section of
straps in mm

Dia of bolts
in mm

[kaM dk O;kl
feeh esa

oksYV dk
O;kl feeh esa

Rs.

Rs.

550
1100
1100
3300
6600

50
75
100
133
150

65
90
115
125
125

25x1.59
31x3
31x5
38x5
38x5

9
12
14
20
20

62.00
79.00
84.00
199.00
276.00

14
14
14
14
14

11000

150

150

38x5

20

309.00

14

M&L
Rs.

EACH
19028 MCCB 3 Pole, 415 V, fixed type, 25 to 100
Amps with breaking capacity 16 KA

3,710

19029 Ditto, but 125 Amps

3,930

19030 MCCB 3 Pole, 415 V, Adjustable type, 160


Amps with breaking capacity 36 KA

7,600

19031 Ditto, but 200 Amps

8,900

19032 Ditto, but 250 Amps

13,900

19033 Ditto, but 350 Amps

17,000

19034 Ditto, but 400 Amps

18,700

19035 Ditto, but 500 Amps

20,900

19036 Ditto, but 630 Amps, 50 KA

24,500
M&L
Rs.

EACH
19037 MCCB 4 Pole, 415 V, Adjustable type, 160
Amps with breaking capacity 36 KA

11,100

19038 Ditto, but 200 Amps

12,900

19039 Ditto, but 250 Amps

16,600

19040 Ditto, but 350 Amps

21,300

19041 Ditto, but 400 Amps

23,200

19042 Ditto, but 500 Amps

24,800

19043 Ditto, but 630 Amps, 50 KA

29,800

19022
19023
19024
19025
19026
19027

379

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z

M&L
Rs.

EACH
19044 MCCB 3 Pole, 415 V, with Microprocessor
release 160 Amps with breaking capacity

36 KA

8,316

19045 Ditto, but 250 Amps

14,970

19046 Ditto, but 400 Amps

19,800

19047 Ditto, but 630 Amps, 50 KA

31,010

19048 Ditto, but 4 Pole, 160Amps, 36 KA

25,760

19049 Ditto, but 4 Pole, 250 Amps, 36 KA

25,830

19050 Ditto, but 4 Pole, 400 Amps, 36 KA

26,950

19051 Ditto, but 4 Pole, 630 Amps, 50 KA

42,420

AIR CIRCUIT BREAKER (ACB)


M&L
Rs.

EACH
19052 ACB 4 Pole, 415 V, with Thermal Magnetic
Release (Manual Fixed type) of capacity

630 Amps

34,340

19053 Ditto, but 800 Amps

35,875

19054 Ditto, but 1000 Amps

39,465

19055 Ditto, but 1250 Amps

56,890

19056 Ditto, but 1600 Amps

60,990

19057 Ditto, but 2000 Amps

70,215

19058 Ditto, but 2500 Amps

85,590

19059 Ditto, but 3200 Amps

129,665

19060 Ditto, but 4000 Amps

198,340
M&L
Rs.

19061 ACB 4 Pole, 415 V, with Thermal Magnetic


Release (Manual Drawout type) of

capacity 630 Amps

67,650

19062 Ditto, but 800 Amps

68,780

19063 Ditto, but 1000 Amps

72,470

19064 Ditto, but 1250 Amps

92,250

19065 Ditto, but 1600 Amps

99,940

19066 Ditto, but 2000 Amps

122,490

19067 Ditto, but 2500 Amps

148,685

19068 Ditto, but 3200 Amps

198,245

19069 Ditto, but 4000 Amps

239,630

380

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
AIR CIRCUIT BREAKER (ACB)
M&L
Rs.
19070 ACB 4 Pole, 415 V, Manual Drawout type
with microprocessor release of capacity

630 Amps

108,395

19071 Ditto, but 800 Amps

109,420

19072 Ditto, but 1000 Amps

114,445

19073 Ditto, but 1250 Amps

139,810

19074 Ditto, but 1600 Amps

149,600

19075 Ditto, but 2000 Amps

178,145

19076 Ditto, but 2500 Amps

211,470

19077 Ditto, but 3200 Amps

266,195

19078 Ditto, but 4000 Amps

307,580

AUTOMATIC POWER FACTOR CORRECTION (APFC) PANEL


M&L
Rs.

EACH
19079 Automatic Power Factor Correction
(APFC) Panel for 3 Phase, 415 V & 50 Hz
system of capacity 20 KVAR without

incoming MCCBs

91,070

19080 Ditto, but capacity 30 KVAR

96,722

19081 Ditto, but capacity 40 KVAR

106,308

19082 Ditto, but capacity 50 KVAR

118,398

19083 Ditto, but capacity 60 KVAR

122,619

19084 Ditto, but capacity 70 KVAR

129,845

19085 Ditto, but capacity 80 KVAR

138,215

19086 Ditto, but capacity 90 KVAR

146,371

19087 Ditto, but capacity 100 KVAR

158,675

19088 Ditto, but capacity 120 KVAR

174,843

19089 Ditto, but capacity 150 KVAR

202,887

19090 Ditto, but capacity 180 KVAR

228,498

19091 Ditto, but capacity 200 KVAR

253,537

19092 Ditto, but capacity 240 KVAR

290,309

19093 Ditto, but capacity 300 KVAR

346,253

381

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
AUTOMATIC VOLTAGE STABILIZER (SERVO CONTROLLED)
M&L
Rs.

EACH
19094 Voltage stabilizer for automatic operation,
three phase naturally oil cooled indoor
type & designed for input variation
between 340 V to 460 V with output
voltage stabilized at 415 with accuracy
2.5% and speed of correction 8 Volts per

second and of capacity 5 KVA


19095 Ditto, but capacity 10 KVA

76,548
79,266

19096 Ditto, but capacity 15 KVA

81,555

19097 Ditto, but capacity 25 KVA

90,283

19098 Ditto, but capacity 50 KVA

124,479

19099 Ditto, but capacity 75 KVA

143,795

19100 Ditto, but capacity 100 KVA

183,857

19101 Ditto, but capacity 200 KVA

372,007

19102 Ditto, but capacity 300 KVA

437,109

19103 Ditto, but capacity 400 KVA

585,482

19104 Ditto, but capacity 500 KVA

639,566

VACUUM CIRCUIT BREAKER (VCB)


M&L
Rs.

EACH
19105 HT 11 KV, 3 phase 50 Hz, indoor type,
totally enclosed metal clad switchgear
complete with Vacuum Circuit Breaker
having rupturing capacity 250 MVA,
overload and earth fault protection,
ammeter, voltmeter and of rating upto 400

Amp.

541,750

19106 Ditto, but rupturing capacity 350 MVA of

rating upto 630 Amp.

571,750

19107 HT 11 KV. 3 phase 50 Hz, indoor type,


totally enclosed metal clad switchgear
complete with Vacuum Circuit Breaker
having rupturing capacity 350 MVA,
overload and earth fault protection,
ammeter, voltmeter and of rating upto 800

Amp.

679,550

19108 Ditto, of rating upto 1200 Amp.

798,390

382

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
VACUUM CIRCUIT BREAKER (VCB)
M&L
Rs.

EACH

954,450

19110 HT 11 KV. 3 phase 50 cycles, outdoor type,


totally enclosed metal clad switchgear
complete with Vacuum circuit breaker
having rupturing capacity upto 250 MVA,
overload and earth fault protection,
ammeter, voltmeter and of rating upto 400

Amp.

608,650

19111 Ditto, but rupturing capacity 350 MVA of

rating upto 630 Amp.

665,430

19109 Ditto, of rating upto 1600 Amp.

SF6 CIRCUIT BREAKER

EACH

M&L
Rs.

19112 HT 11 KV, 3 phase, 50 cycles totally


enclosed metal clad SF6 switchgear
having rupturing capacity upto 250 MVA,
overload and earth fault protection,
ammeter, voltmeter and of rating upto 400

Amp.

558,210

19113 Ditto, but rupturing capacity 350 MVA of

rating upto 630 Amp.

587,850

19114 HT 33 KV, 3 phase, 50 cycles totally


enclosed metal clad SF6 switchgear
having rupturing capacity upto 250 MVA,
overload and earth fault protection,
ammeter, voltmeter and of rating upto 400

Amp.

1,063,530

19115 Ditto, but rupturing capacity 350 MVA of

rating upto 630 Amp.

1,094,550

OUTDOOR
19116 HT 11 KV, 3 phase, 50 cycles totally
enclosed metal clad SF6 Switchgear
having Rupturing capacity upto 250 MVA,
overload and earth fault protection,
ammeter, voltmeter and of rating upto 400

Amp.

619,730

383

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
SF6 CIRCUIT BREAKER

EACH

M&L
Rs.

19117 Ditto, but rupturing capacity 350 MVA of

rating upto 630 Amp.

640,580

19118 HT 33 KV, 3 phase, 50 cycles totally


enclosed metal clad SF6 Switchgear
having Rupturing capacity upto 750 MVA,
overload and earth fault protection,
ammeter, voltmeter and of rating upto 400

Amp.

1,253,060

19119 Ditto, but rupturing capacity 350 MVA of

ratinejipto 630 Amp.

1,250,350

EACH

M&L

Fixing only

Disc type insulator, porcelain, vitreous


145mm high and 255mm dia ball and
socket type, white, brown or green:

lkexzh ,ao Je

dsoy LFkkiu

Rs.

Rs.

19120'Two-in-series' assembly for tension


with tension clamps for conductors,
working pressure 11000 volts
19121Single disc assembly for ditto
19122Reel type insulator, 40mm dia x

20mm high x 12mm hole

877.00
552.00

103.00
74.00

23.00

14.00

19123Ditto 65mm dia x 31mm high x

20mm hole

35.00

14.00

EACH

M&L

Fixing only

Loop type insulator, vitreous porcelain, lkexzh ,ao Je

dsoy LFkkiu

white, brown or green:


19124Small size, with overall dimensions
65 x 90mm, clearance of hole 16mm

Rs.

Rs.

38.00

14.00

19125Large size, with overall dimensions


140mm, clearance of hole 25.5mm

45.00

14.00

PER QUINTAL
19126Galvanised stay strand, 7/4mm

5914.00

520.00

19127Ditto 7/3.15mm, ditto

5941.00

547.00

19128Ditto 7/2.50mm. ditto

6008.00

613.00

19129Ditto 7/2.24mm. ditto

6054.00

660.00

iz R ;s d
p leku dkapkf;r phuh feh ds fo|qr
vojks/kd] 145 feeh ps o 255 feeh O;kl cky
o dksVj tSls] lQsn] Hkwjs ;k gjs%
19120
19120f}Ja[kyk lek;kstu] ruko ls ruko f'kdats
lapkyd gsrq lf; ncko 11000 oksYV
19121
19121,dy plek;kstu gsrq mi;qZDr
19122
19122pj[kh uqek fo|qrjks/kd 40 feeh O;kl
20 feeh apk
19123
19123mi;qDZ r pj[kh uqek] O;kl 65 feeh 31
feeh apk 20 feeh fNnz
iz R ;s d
QUnk uqek dkapf;r phuh feh ds lQsn] Hkwjs ;k
gjs fo|qrjks/kd
19124
19124NksVs vkdkj ds 65 90 feeh dqy ifjeki]
16 feeh O;kl fudkl fNnz ds NksVh fdLe ds
19125
19125cMs vkdkj ds 90 140 feeh dqy ifjeki]
25-5 feeh O;kl fudkl fNnz

iz f r fda o Vy
19126
19126tLrh 7@4 feeh rku yM+ vkdkj
19127
19127tLrh 7@3-15 feeh rku yM+ vkdkj] mi;qDZ r
19128
19128tLrh 7@2-5 feeh rku yM+ vkdkj] mi;qDZ r
19129
19129tLrh 7@2-24 feeh rku yM+ vkdkj] mi;qDZ r

384

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
STAY ASSEMBLY
rku lek;ks t u
M&L
Fixing only
Diameter of
(excluding)
stay rod in mm fabrication

PER SET

lkexzh ,ao Je
rku NM+- dk
O;kl feeh esa

19130Stay assembly complete with


accessories as shown in electrical
plate No. 1 (loop type insulator, stay 20mm 16mm
Rs.
Rs.
clamps, excavation and concrete
834.00 605.00
measured separately)

dsoy LFkkiu
lsjpuk jfgr
Rs.
233.00

izfr lSV

19130
19130rku lewg] fo|qr lwph ekad 1 esa iznf'kZr
vuqlkj] milk/ku lfgr laiw.kZ Qankuqek
fo|qrjks/kd rku f'kdats] [kqnkbZ] o dahV
izFkd ekis tk;saxs

OVERHEAD CONDUCTORS
'kh"kZ L Fk la p kyd
(a) The 'M & L' and 'fixing only' rates include supply and
fixing of copper binding wire or aluminium tapes which
shall not be included in the weight of conductors.

(b) Weight of ACSR or all aluminium conductors drawn for


overhead lines is to be determined by measuring taut
horizontal distance between centres of two adjacent
poles and compounding the weight of conductors of
that size and length and 3% extra added for sag, jointing,
jumpers, etc.
(c) Weight of conductors shall be calculated from the tables
given in the relevant I.S. Where the weight of any conductor
is not given in the I.S. it shall be calculated using standard
tables of the electrical conductors supplied by the makers.

[k

PER QUINTAL
19131Aluminium conductor, steel

reinforced

19132All aluminium conductor


19133Galvanised steel wire 3.15 or 4mm

dia

19134Ditto, stranded 7/1.6min


19135Ditto, stranded 7/2.24mm

lk o Je rFkk dsoy LFkkiu dh njksa esa rkaos ds ca/ku rkj


o vY;qeqfu;e ifk;ksa ftudk Hkkj lapkyd ds lkFk ugha
tksM+k tk;sxk] dh vkiwfrZ o LFkkiu 'kkfey gSA
'kh"kZLFk rkjksa ds fy;s ,slh ,l vkj ;k iw.kZ vYeqfu;e
lapkyd dk Hkkj nks [kaHkksa ds chp lekukUrj Qklys eki dj
vkadk tk;sxk rFkk mlh vkdkj ds lapkydksa ds Hkkj esa feyk
fn;k tk;sxk rFkk <ky] tqM+koksa] >aidks vkfn ds fy, 3%
vfrfjDr tksMk+ tk;sxkA
lapkydksa dk Hkkj lacfU/kr ekud lwph esa fn;s x;s lw= ds
vuqlkj vkadk tk;sxkA tgak fdlh lapkyd dk Hkkj ekud
lwph esa ugha fn;k gks rks mldk Hkkj fuekZrk }kjk iz;qDr
ekud lwph vuqlkj vkadk tk;sxkA

M&L

Fixing only

lkexzh ,ao Je

dsoy LFkkiu

Rs.

Rs.

19168.00
18062.00

736.00
736.00

6130.00

736.00

6130.00

736.00

6130.00

736.00

iz f r fdoa V y
19131
19131vYeqfu;e lapkyd] izofyr bLikr
19132
19132iw.kZr;k vYeqfu;e
19133
19133tLrh bLikr ds rkj 3-15 ;k 4 feeh O;kl
19134
19134dybZnkj cVnkj rkj yM+h 7@1-6 feeh
19135
19135mi;qZDr] yM+hnkj rkj 7@2-24 feeh

385

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
LINE CONNECTORS
ykbu la ; ks t d
Material & labour
suitable for conductor
size

EACH

19136Vice
type
connectors
consisting of two brass plates,
and two steel bolts and nuts
for 2 conductors of equal or
unequal sizes, for non-tension
connections
'including
treatment of connector and
ACSR conductor with

conducting jelly

laokgd vkdkjuqlkj
lkexzh ,oa Je
4 to 7mm
dia

10 to 13mm
dia

4 ls 7 feeh
O;kl

10 ls 13 feeh
O;kl

Rs.

Rs.

54.00

61.00

iz R ;s d

Fixing only
any size

dsoy LFkkiu
dksbZ vkdkj 19136
19136f'kdatkuqek la;kstd nks ihry dh
IysV vkSj le ;k vle nks laokgdkas
gsrq nks yksgs ds dkuys o f<fj;kn]
vkrfr jfgr la;kstu gsrq la;kstd
vkSj ,lh,lvkj lapkyd dk
pkyd tSyh ls mipkj
Rs.

23.00

LINE TAPS
ykbu VS I l
EACH

Materials & Labour

Fixing only

lkexzh ,oa Je

dsoy LFkkiu

iz R ;s d

Dia of thicker wire in mm

eksVs rkj dk O;kl feeh esa


19137Vice
type
taps, 3 to 10mm Above 10 and 3 to 10mm Above 10 and
consisting of two brass
upto 14mm
upto 14mm
plates and one bolt and 3 ls 10 feeh 10 ls 14 feeh 3 ls 10 feeh 10 ls 14 feeh
nut for connecting 2
rd
rd
rd
equal or unequal size
Rs.
Rs.
Rs.
Rs.
conductors for service

wire
54.00
61.00
23.00
23.00

19137
19137f'kdatkuqek VSi ftlesa nks
lsok rkj gsrq nks le ;k
vle lapkydksa dk la;kstu
djus ds fy;s nks ihry dh
IysV o ,d dkoyk o ,d
f<ojh
iz R ;s d

M&L

EACH

lkexzh ,oa Je
Overall dia of conductor

dqy O;kl
19138Compression/crimping
type sleeve joints for
jointing conductors/
jumper connections
including treatment with

conducting jelly

Upto 10mm dia of


conductor wire overall

Above 10mm dia of


conductor wire overall

rkj dk dqy 10 feeh O;kl rkj dk dqy O;kl 10 feeh


ls ij
Rs.

Rs.

153.00

197.00

19138
19138laihMu@laMklh uqek Lyho
tksM+ lapkydks@
a >aij la;kstuksa
dks tksM+us ds fy, laokgd
tSyh ds mipkj lfgr

386

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
GUARDING
la j {k.k
PER QUINTAL
19139 Cradles, hexagonal/rectangular,
fabricated with galvanised steel

wire 3.15 or 4mm dia


19140 Anti climbing devices; comprising
2.24mm dia galvanised steel
2-strand barbed wire with
2.00mm dia barbs wrapped
spirally round poles, to a length of
0.5 to 1.0 metre clamped and
properly secured or as ordered
(clamps measured separately)
19141 Anti-climbing device; spikes type
fabricated out of M.S. bars (round,
square and flat) including nuts,
bolts, washers and welding in two
halves made to shape to suit the

cross section of the pole

M&L

Fixing only

lkexzh ,ao Je

dsoy LFkkiu

Rs.

Rs.

6866.00

1471.00

6866.00

1471.00

6398.00

2101.00

iz f r fDoa V y
19139 >wys dSMy] "kVdks.k@vk;rkdkj] 3-15
;k 4 feeh O;kl] tLrh bLikr rkjksa ls
fojfpr
19140 vkjksg.k jks/kh] lk/ku ftuesa 2-24 feeh
O;kl tLrh bLikr 2&yM+h rkj tkyh
lkFk esa 2-24 O;kl ds dkaVs lfgr [kaHks ds
pkjksa vksj lfiZy yisVs gq;s 0-5 ls 1-0 eh
yEcs] dlds ifk;ka yxh funZs'kkuqlkj
iw.kZ lqjf{kr ifk;k dh eki izFkd gksxh
19141 vkjksg.k jks/kh lk/ku] uje bLikr ds
lfj;k ls fojfpr xksy] pkSdksj o likV
dkoys] f<jh ok'kj lfgr rFkk nks v/kZ
Hkkxksa esa Vkadh yxkrs gq, ,slh vkd`fr tks
[kaHks ds ledks.kh; dkV esa yxkus ds
mi;qDr gks

DANGER BOARDS
[krjs dh rf[r;k
EACH

M&L

Fixing only
any size

iz R ;s d

19142 Danger notice plate of 1.6mm thick


mild steel sheet, vitreous enamelled
white, with letters, figures and
conventional skull and bones in
signal red colour and fixed with
M.S. clamps, bolts and nuts of
approved size, for LT, 20x15cm

size

lkexzh ,ao Je

dsoy LFkkiu
fdlh lkbTk

Rs.

Rs.

89.00

14.00

108.00

14.00

19142 [krjk lwpuk] 1-6 feeh eksVh uje bLikr


dh pknj ls cuh dkapkf;r 2015 lseh
vkadkj ds fuEu ruko gsrq eksVh lQsn
ijr ij 'kCn] vad rFkk ijEijkxr
[kksiM+h o gf;ka lkadsfrd yky jax ls
cus Lohd`r vkdkj ds uje bLikr dh
if;ka dkoyksa o f<fj;ksa ls yxh
19143 mi;qDZ r vkdkj 2520 lseh mPp ruko
gsrq

19143 Ditto for HT, 25x20cm size

387

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
AERIAL FUSES
fo|qrxzkgh ,fj;y I;wt ofrZ;kn
EACH

Maximum current in amps

iz R ;s d

Fixing only any size


amperage & any dia
of line wire

,Eil esa vf/kdre /kkjk


Materials and Labour

lkexzh ,oa Je
Maximum dia of line wire in mm

dsoy LFkkfir izokg rkj


dksbZ ,Ei o O;kl

rkj iz.kkyh O;kl vf/kdre


15 amp
19144Porcelain aerial
fuses suitable for line 3 mm
wire, with brass
Rs.
contact bolts and
27.00
nuts

30 amp
3 mm

60 amp
3 mm

Rs.

Rs.

Rs.

41.00

50.00

14.00

19144
19144dka p kf;r fo|q r xz k g
ofrZ;k] izokg rkj ds
mi;qDr ihry ds laidZ
dkoys o f<fj;ksa ds lkFk

EXPULSION FUSES
fu"dklu ;w t
EACH

iz R ;s d

6600 volts
11000 volts
6600 oksYV
11000 oksYV
Upto 25 Above Above upto 25 Above Above
amp
25 &
50&
amp
25 &
50&
upto 50 upto 100
upto 50
upto
amp
amp
amp 100 amp

25 ,Ei
rd
19145Expulsion fuse single

pole

25 ls
50 ls
mij 50 mij 100
,Ei rd ,Ei rd

25 ,Ei
rd

Rs.

Rs.

Rs.

Rs.

605.00

624.00

717.00

809.00

25 ls
50 ls
mij 50 mij 100
,Ei rd ,Ei rd
19145
19145,dy [kaHks ds fu"dklu
;wt
877.00 1009.00
Rs.

Rs.

SWITCHES AIR BREAK, GANG OPERATED


ok;q pkfyrjks/kd cVu] lewg lapkfyr
M&L

EACH

lkexzh ,ao Je
19146Triple pole, mechanically operated,
mounted on insulator and steel
frame, with operating mechanism
worked from ground level, for

current rating upto 200 amps


19147Ditto, but for current rating
upto 400 amps

600 volts
600 oksYV
Rs.

11000 volts
11000 oksYV
Rs.

4561.00

6648.00

6744.00

9257.00

iz R ;s d
19146
19146rhu 'kk[kk [ka H kk] ;ka f =d pkfyr]
fo|qrjks/kd o bLikr se ij vkjksfir]
200 ,Ei rd fu/kkZfjr /kkjk ds fy;s Hkqfery
ls ;kaf=d lapkyu lfgr
19147
19147mi;qZDr] fdUrq 400 ,Ei rd la;kstu
fu/kkZj.k gsrq

388

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
AIR-BREAK (SWITCH) ISOLATORS
ok;q vojks/kd cVu fo;kstd
M&L

Fixing only

lkexzh ,oa Je

dsoy LFkkiu

EACH
Single pole, for indoor use

iz R ;s d
,d [kEHkk] ?kjsyw iz;ksx gsrq

Suitable for current rating of

/kkjk fu/kkZj.k gsrq mi;qZDr

19148Air break (switch)


insulator for 6600 volts

200 amp

400 to 800
amp

200 amp

400 to 800
amp

200 ekid

400 ls 800
ekid rd

200 ekid

400 ls 800
ekid rd

Rs.

Rs.

Rs.

Rs.

3648.00

4214.00

736.00

736.00

4987.00

5266.00

1005.00

1005.00

19149Ditto, for 11000 volts

19148
19148ok;q jks/kd cVu 6600 oksYV
fo|qr jks/kd
19149
19149mi;qZDr] 11000 oksYV ds
fy,
,d [kaHkk] ckgjh iz;ksx gsrq

Single pole, for out door use


19150Air break (switch)
insulator for 6600 volts 10309.00
19151Ditto, for 11000 volts
11178.00

11613.00

1005.00

1005.00

13801.00

1005.00

1005.00

19150
19150ok;q jks/kd cVu fo|qr
jks/kd 6600 oksYV ds fy;s
19151
19151mi;qDZ r] 11000 oksYV ds fy,

ARRESTERS LIGHTNING LOW TENSION


izdk'k fuxzg fuEu ruko
PER SET
19152L.T. lightning arresters for outdoor
use, non-liner resistor type, horn gap
and choking coil, maximum working

pressure 1100 volts


19153Lightning arresters expulsion type
complete with all fittings, 30 kilo amp
discharge capacity, distribution

class

M&L

Fixing only

lkexzh ,ao Je

dsoy LFkkiu

Rs.

Rs.

1868.00

233.00

3130.00

233.00

izfr lSV
19152
19152fuEu ruko izdk'k fuxzg] ckgjh iz;ksx ds
fy, vladqfpr vkojks/kduqek] NksVs Nsn
rFkk jksd xSMjq h] vf/kdre dk;Zdkjh ncko
1100 oksYV
19153
19153izdk'k fuxzg fu"dklu Vkbi] 30 fdyks
izokg fudkl {kerk o fooj.k Js.kh ds lHkh
miLdjksa lfgr] laiw.kZ

389

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
ARRESTERS LIGHTNING HIGH TENSION
izdk'k fuxzg mPp ruko
PER SET
19154Lightning arresters
expulsion
type
complete with all
fittings, transmission
class,
discharge
capacity 65 kilo amp

M&L

Fixing only

lkexzh ,oa Je

dsoy LFkkiu

izfr lSV

19154
19154izdk'k fuxzg fu"dklu
mi;qDr oksYV ds fy,
Vkbi] 65 fdyks izokg
fudkl {kerk o
3300
6600 11000 33000 3300 6600 11000 33000
izfo"Vd Js.kh ds fy,
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
miLdjksa lfgr] laiw.kZ
2737.00 3805.00 4613.00 9865.00 233.00 233.00 350.00 466.00
Suitable for volts

TRANSFORMERS
V k la Q kjej ifj.kkfe=
(a) The rates include for supplying transformers with standard
fittings and installing complete including all jointing
materials, connecting with electrical system, earthing,
testing and commissioning but exclude connecting cables,
steel mounting fabrications, earthing & P.CC if any, which
shall be measured separately.
(b) The transformer will have its initial oil filling to
appropriate level (cost of oil including testing with desired
dielectric strength included in supplied and installed rates).
EACH

19155Transformer step-down, 11/0.433


KVA complete, outdoor/indoor,
aluminium wound, capacity 25

KVA

[k

bu njksa esa] ValQkjejksa dh ekud la;kstuksa lfgr liwfrZ


djuk rFkk lHkh la;kstu lkexzh lfgr fo|qr iz.kkyh ls
tksMuk Hkwfe LFkj tkap o pkyw djuk lfgr laiw.kZ djuk
'kkfey gS] yfdu dsoy tksM+uk] yksgs dh jpuk] HkwfeLFkj.k
o ihohlh dk;Z ;fn gks rks og izFkd ekik tk;sxkA
VaklQkjej esa mi;qDr ek=k esa rsy Hkjk gksxk rsy dk ewY;
o okafNr vfo|qr 'kfDr dh tkap dks laifw rZ o LFkkiu njksa esa
'kkfey fd;k x;k gSA

Supplied &
installed

Installation
only

laiwfkZ o LFkkiuk

dsoy LFkkiuk

Rs.

Rs.

67391

806

19156Ditto, but 63 KVA

120902

941

19157Ditto, but 100 KVA

161394

1008

19158Ditto, but 160 KVA

242091

1176

19159Ditto, but 200 KVA

310769

1243

19160Ditto, but 250 KVA

353836

1411

19161Ditto, but 315 KVA

468014

1595

19162
19163Transformer, step-down, 11/0.433
KVA complete, outdoor/indoor,
copper wound capacity 25 KVA

83150

806

19164 Ditto, but 63 KVA

148710

941

19165 Ditto, but 100 KVA

202601

1008

19166 Ditto, but 160 KVA

293743

1176

19167 Ditto, but 200 KVA

369146

1243

iz R ;s d
19155
19155mipk;h VkalQkjej 11@0 433 ds oh ,
laiw.kZ vY;qfefu;e ckmUM] ckgjh@Hkhrjh
{kerk 25 ds oh ,

19156
19156mi;qZDr]
19157
19157mi;qZDr]
19158
19158mi;qZDr]
19159
19159mi;qZDr]
19160
19160mi;qZDr]
19161
19161mi;qZDr]

fdUrq
fdUrq
fdUrq
fdUrq
fdUrq
fdUrq

63 ds oh ,
100 ds oh ,
160 ds oh ,
200 ds oh ,
250 ds oh ,
315 ds oh ,

19162
19163
19163mipk;h Vkl
a Qkjej 11@0-433 ds oh , lai.w kZ
dkij ckmUM Hkhrjh@ckgjh {kerk 25 ds oh ,
19164
19164mi;qZDr] fdUrq 63 ds oh ,
19165
19165mi;qZDr] fdUrq 100 ds oh ,
19166
19166mi;qZDr] fdUrq 160 ds oh ,
19167
19167mi;qZDr] fdUrq 200 ds oh ,

390

SECTION 19

SECTION 19ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
TRANSFORMERS
V k la Q kjej ifj.kkfe=
EACH

Supplied &
installed

Installation
only

laiwfkZ o LFkkiuk

dsoy LFkkiuk
Rs.
1411

19168Ditto, but 250 KVA

Rs.
423516

19169Ditto, but 315 KVA

488904

1595

19170Ditto, but 400 KVA

559013

1802

19171Ditto, but 500 KVA

671616

2036

19172Ditto, but 630 KVA

769769

2301

19173Ditto, but 750 KVA

1045484

2600

19174Ditto, but 1000 KVA

1122890

2938

19175Ditto, but 1250 KVA

1325920

3320

19176Ditto, but 1500 KVA

1362405

3752

19177Ditto, but 2000 KVA

1646133

4239

iz R ;s d

19168
19168mi;qZDr]
19169
19169mi;qZDr]
19170
19170mi;qZDr]
19171
19171mi;qZDr]
19172
19172mi;qZDr]
19173
19173mi;qZDr]
19174
19174mi;qZDr]
19175
19175mi;qZDr]
19176
19176mi;qZDr]
19177
19177mi;qZDr]

fdUrq
fdUrq
fdUrq
fdUrq
fdUrq
fdUrq
fdUrq
fdUrq
fdUrq
fdUrq

250 ds oh ,
315 ds oh ,
400 ds oh ,
500 ds oh ,
630 ds oh ,
750 ds oh ,
1000 ds oh ,
1250 ds oh ,
1500 ds oh ,
2000 ds oh ,

391

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
HOUSE SERVICE BRACKETS
xzg lsok dks"Bd
(a) The rates include cutting holes in walls etc. of any
description, grouting rag bolts or rag angle iron service
bracket, and making good with cement mortar 1:3 including
making good finishing to match the existing work and
removing rubbish off MOD premises.
(b) Where the length of G.I. pipe or angle iron service brackets,
etc. is ordered to be different than the length specified,
adjustment in prices shall be effected at supply only rates
of the material under appropriate sections.

[k

(c) G.I. pipe house service bracket hook type shall be fabricated
with 3.0 m long screwed G.I. pipe of medium quality and
will comprise of two No. 90 bends (pipe dia) screwed tight
to the top ends of the service vertical limb, the two ends of
the service shall be provided with two Nos. of turned spit
tight fit, well seasoned teakwood bushings and the bracket
shall be fixed plumb vertical against the wall with twv Nos.
flat iron clamps (fabricated out of 50x6 mm flat iron with 4
No. 16 mm dia ragged bolts of appropriate size with screwed
ends, tightened with 16 mm dia nuts with 6 mm thick washer
against the clamp tightening collars). The rate includes cost
of 30 x 5 mm MS flat hook, bolts & nuts & stranded
galvanised, wire stay (guy).

+ x

(d) Angle iron service bracket shall have one end ragged and
grouted into the wall and other end drilled with 16mm or
20mm dia hole for fixing service shackle insulator
supporting bolt.

?k

(e) To take in service shackle fixing height of the service bracket


should be such as to have horizontal run of the service from
the take off service bracket pole.

EACH

M& L

lk ,oa
Je
19178 House service bracket (hook type
Rs.
complete with 3.0m long G.I. pipe 40mm
0
dia Med. grade, two nos90 bends. M.S.
783.00
hook and stay or guy
1137.00
19179 Ditto, but with 50mm dia G.I. pipe and ditto

Fixing
only

dsoy
LFkkiu
Rs.
70.00
93.00

bu njksa eas nhokj vkfn esa fdlh Hkh izdkj ds Nsn dkVuk :{k
dkoys ;k :{k yksgs ds lsok dks"Bd 1%3 ds lhesVa elkys ls
fo|eku lrg ls feykrs gq;s yxkrs gq, lai.w kZ djuk rFkk eyos
dks izfrj{kk foHkkx dh lhek ls ckgj ys tkuk 'kkfey gSA
tgkn yksgs ds <ys uy ;k yksgs dh NM+ ds dks"Bd Lohd`r
yEckbZ ls fHkUu yEckbZ ds yxkus dks dgk tk; rks ewY; ds
vUrj dk mi;qDr [kaM ds vUrZxr dsoy vkiwfrZ dh njsa
izHkkfor gksx
a hA
yksgs ds <ys dkaVs tSls xzg lsok dks"Bd dks 3-0 eh yEcs e/;e
dksfV ds <ys yksgs ds nkarns kj uy ls fojfpr fd;k tk;sxk rFkk
mlesa nks 90 dks.k ds eksM+ uy O;kl ls lsok vo;o ds ij
fdukjs ls ispksa ls dluk] nks eqMs+ gq, lhdapksa ls nksuksa fdukjksa
dks tdM+ dj lkxkSu dh ydM+h xYdksa ls nhokj es]a nks likV
yksgs dh iRrh ls yxkukA 506 feeh likV yksgs ls cuh
ifk;ksa dks 4 ua- ds 16 feeh O;kl ds :{k mi;qDr uki f<ofj;ka
ls nkarns kj fdukjksa dks 16 feeh O;kl ds dkoys dks dlus okys
dkyj dh iRrh ds lkFk 6 feeh ds ok'kj yxkdj dls gq;s bl
ewY; esa 305 feeh uje yksgs ds dkaVs f<ofj;ka o dkoys rFkk
x<+s rFkk ca/ks rkj ds xqPNs xos dk ewY; 'kkfey gSA
yksgs dh lfj;k ds lsok dks"Bd dk ,d :{k fdukjk nhokj
esa xk<+k tk;sxk ,oa nwljs fdukjs esa 16 feeh ;k 20 feeh dk
cjes ls Nsn fd;k tk;sxk ftlesa tqM+s fo|qrjks/kd dks lgkjs
nsus okyh f<ojh yxsxhA
lsok dks"Bd dh pkbZ[kaHks dh lsok dks"Bd ds lekukUrj
gksuh pkfg;s rkfd lsok lkekukUrj cgko esa nkSM+sA
iz R ;s d

19178
19178xzg lsok dks"Bd gqd uqek] 3-0 eh yEcs tLrh
yksgs ds uy] 40 feeh O;kl] e/;e Js.kh nks] 90
eksM+] uje yksgs ds gqd o MkV ;k xqPNh lfgr
lai.w kZ
19179
19179mi;qDZ r] fdUrq 50 feeh O;kl x<s uy vkSj mi;qDZ r

392

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
HOUSE SERVICE BRACKETS-Contd...
xzg lsok dks"Bd tkjh
EACH

M& L

lkexzh ,oa Je
40406mm angle 50506mm angle
40406 feeh ,axy 50506 feeh ,axy
Rs.
Rs.
19180 Angle iron service

bracket
310.00
427.00

Fixing only
any size

iz R ;s d

dsoy LFkkiu
dksbZ vkdkj
Rs.
93.00

19180
19180yksgs ds ,axy okys] lsok dks"Bd

SERVICE CONNECTIONS
lsok la;kstu
(a) The rates cater for a single twin core or a set of two single
core run weather proof cables with aluminium conductors
fixed between service pole and service bracket and include
all jointing materials, labour, catenary, (curved) G.I. wire,
hangers, spacing porcelain insulators, service shackle
insulator both on service pole and service bracket with
iron fixing accessories/parts/ materials, like hook eye bolls
with nuts and washers, spacer sleeves for spacing service
shackle insulator apart, G.I. or painted flat iron shackle
holding tension M.S. strips, pole clamp for holding service
shackles at poles, etc.

d ;g njsa vY;qfu;e lapkyd ds lkFk ,d ,dy f}varHZ kkxh; ;k


nks ,dy varZHkkxh; lewg dh Jrq lg dscy dk izcU/k djrh
gSa tks lsok dks"Bd ,oa lsok [kaHks ds chp yxh gSa rFkk lHkh
la;kstu lkexzh] Je] izcU/ku frjNs yksgs ds tLrh rkj]
vxZuh] dkapk;qDr varj.k fo|qr jks/kd] fux< fo|qr jks/kd] lsok
[kaHks vkSj dks"Bd nksuksa ij] lkFk esa yksgs dh LFkkiu
lgk;d@vo;o@lkexzh tSls dkaVs] f<ofj;ka dkoys o ok'kj
lfgr] lsok fux< fo|qr jks/kd vyx j[kus ds fy, varjh;
vkoj.k yksgs ds <ys ;k jksxu fd;s likV yksgs ds ruko /kkjd
nks eqagh dkaMh csMh] uje yksgs dh ifk;ka] [kaHks dh if;ka] [kaHks
tks eqagh dMh dks [kaHks ij lk/ks jgrh gSa vkfnA
(b) The length shall be measured as the taut horizontal distance [k yEckbZ] lsok [kaHks vkSj lsok dks"Bd ds chp lh/kh ekih tk;sxhA
between service pole and service brackets.
(c) The weather proof cable run from the service bracket to the
distribution board or mains controlling switch will be laid
partly through the pipe of the service bracket and partly
laid through service pipe and on well seasoned teak wood
battens, neatly clipped. 20mm G.I. pipe where so ordered
on these runs will be measured separately under appropriate
items.
(d) The weather proof service cable from angle iron service
bracket will be laid either through G.I. pipe of appropriate
diameter as directed by the Engineer-in-Charge or on well
seasoned teak wood battens, as ordered, from the angle iron
service bracket to the control isolating switch or main switch
board, and cable lengths will be measured separately.
(e) Earth work, sand cushioning, PCC cable cover, provision
of G.I. pipe for protection against mechanical damage under
roads, floor, on wall or along the poles etc. shall be
measured separately for heavy duty armoured cable.

x tyok;q lg dsoy fLop tks lsok dks"Bd vkSj forj.k cksMZ ;k


eq[;/kkjk fu;a=d in fLop vkaf'kd :i esa lsok dks"Bd ds uyksa
esa ls vkSj vkaf'kd :i esa lsok uyksa esa ls rFkk etcwr lkxkSu dh
ofYy;ksa ij vPNh rjg ifk;ka yxkdj Mkyh tk,sxhA 20 feeh
ds yksgs ds tLrh uy tgka ,slh /kkjk yxkus dk ,slk vkns'k gks
rks og mi;qDr enksa ds vUrxZr izFkd ekik tk;sxkA
?k tyok;q lg lsok dsoy] yksgs ds ,axy dh lsok dks"Bd ls] izHkkjh
vfHk;ark ds funsZ'kkuqlkj ;k rks mi;qDr O;kl ds yksgs ds tLrh
uy esa ;k yksgs ds ,axy okyh lsok dks"Bd ls fu;a=d izFkd
cVu ;k eq[;/kkjk fu;a=d in ls etcwr lkxkSu dh ofYy;ksa ls
Mkyh tk;sxh rFkk dsoy dh yEckbZ izFkd ekih tk;sxhA
M feh dk;Z] jsr HkjkbZ] izofyr lhesaV dahVds vkoj.k] rFkk
lM+dks]a Q'kks]Z ;k nhokjksa ;k [kaHkksa ds lkFk] ;kaf=
+ dh gkfu ls cpko
ds fy, yksgs ds tLrh uy dh O;oLFkk vkfn dks Hkkjh dk;Z
fu;kstd dsoy gsrq izFkd ekik tk;sxkA
(f) The rates however for connecting cable with cable p gkykafd dsoy dks dsoy vUrd Nksj lkdsV ls varLFk esa cVu
termination end sockets into terminal switches is included
esa tksMu+ s dk dk;Z bu njksa esa 'kkfey gS ysfdu [kaHkksa ;k forj.k
but terminal joints on poles or distribution pillars shall be
LrEHkksa ij vURe la;kstu izFkd ekik tk;sxkA
measured separately.

393

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
SERVICE CONNECTIONS-Contd...
lsok la;kstu tkjh
PER RUNNING METRE

Size of aluminium conductor in mm2 (sq mm)

vYeqfu;e lapkyd vkdkj esa feeh oxZ feeh


19181 Supplying and fixing 1100
volts grade heavy duty cable
Solid conductor
Stranded conductor
PVC insulated aluminium
Bksl lapkyd
ekud lapkyd
conductor, served with inner
4
6
10
16
4
6
10
16
sheathing of PVC tape and
overall PVC sheathed in
service connections suspended by insulating hangers not
more than 1 metre apart
including4mm suspension
wire, one twin core cable flat
29.00 33.00 38.00 46.00 30.00 34.00 41.00 59.00

or circular
19182 Ditto, but with two single

core cables
38.00 42.00 46.00 55.00 39.00 44.00 50.00 59.00
19183 Add to item 19182 for
each additional single

core cable
14.00 16.00 18.00 22.00 15.00 17.00 20.00 23.00

izzfr ehVj
19181
191811100 oksYV Js.kh ds xq: dk;Z
ihohlh /kkjkjks/kd vYeksfu;e ds
lapkyd vUnj ls ihohlh ih o
pkjksa vksj ihohlh ls e<s+ gq;s lsok
la;kstuksa esa /kkjkjks/kd [kwaVh ls
1eh ls vuf/kd Qklys ij yVds]
4 feeh ypdnkj rkj ,d
vUrHkkZxh; likV ;k xksy dsoy
lfgr

19182
19182mi;qDZ r] ijUrq nks ,dy vUrHkkZxh;
likV ;k xksy dsoy lfgr
19183
19183izR;sd vfrfjDr ,dy varHkkZx
ds fy, en 19182 esa tksMa+s

iz f r ehVj
19184
191841100 oksYV oxZ xq: dk;Z dsoy( lkFk
Stranded conductor
esa ihohlh fo|qr jksf/kr vYeqfu;e
ekud lapkyd
lapkyd tks ihohlh iV~Vs dk Hkhrjh
2 core 3 core 4core
vkoj.k ls tLrh bLikr rkj ;k iV~Vs
ls x<s gq;s rFkk lai.w kZ ihohlh dksf"kr]
lsok la;kstuksa esa 4 ofeeh ukHkh; vuqiLz Fk
dkV( dh vkiwfrZ] rFkk fcNkbZ ;k LFkkiu
;k uyksa esa ls fudkyuk

PER RUNNING METRE

Materials & Labour

lkexzh ,oa Je

19184Supply and laying or


Solid conductor
fixing or passing through
pipe, 1100 volts grade heavy
Bksl lapkyd
duty cable with PVC 2 core 3 core 4 core
insulated
aluminium
conductor served with an
inner sheathing of PVC tape
armoured with galvanised
steel wire or tape and overall
PVC sheathed 4 sq. mm
nominal cross section in

service connections
60.00 66.00 77.00 62.00 71.00 81.00
19185 Ditto, but 6 sq. mm
19186 Ditto but 10 sq. mm
19187 Ditto but 16 sq. mm

72.00

79.00

96.00

85.00

94.00 102.00

76.00 83.00

99.00

89.00 98.00 104.00


98.00 111.00 138.00

19185
19185mi;qZDr] ijUrq 6 oxZ feeh
19186
19186mi;qZDr] ijUrq 10 oxZ feeh
19187
19187mi;qZDr] ijUrq 16 oxZ feeh

394

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
CABLE TERMINATION 11 KV HT (COLD SHRINKABLE)
M&L
Rs.

EACH
19188 Cable jointing kit for 11 KV (Earthed) grade
cable for indoor termination cold shrink
type joint complete with jointing material
and accessories suitable for 3 core XLPE
armoured aluminium conductor cable of

size 16 sqmm to 35 sqmm

9183

19189 Ditto, but 50 sqmm to 95 sqmm

10469

19190 Ditto, but 120 sqmm to 185 sqmm

12396

19191 Ditto, but 240 sqmm to 300 sqmm

12971

19192 Ditto, but 400 sqmm

14037

19193 Cable jointing kit for 11 KV (Earthed) grade


cable for outdoor termination cold shrink
type joint complete with jointing material
and accessories suitable for 3 core XLPE
armoured aluminium conductor cable of

size 16 sqmm to 35 sqmm

14868

19194 Ditto, but 50 sqmm to 95 sqmm

16731

19195 Ditto, but 120 sqmm to 185 sqmm

18396

19196 Ditto, but 240 sqmm to 300 sqmm

20198

19197 Ditto, but 400 sqmm

21240

19198 Cable jointing kit for 11 KV (Earthed) grade


cable for straight through cold shrink type
joint complete with jointing material and
accessories suitable for 3 core XLPE
armoured aluminium conductor cable of

size 16 sqmm to 35 sqmm.

19107

19199 Ditto, but 50 sqmm to 95 sqmm

21387

19200 Ditto, but 120 sqmm to 185 sqmm

27207

19201 Ditto, but 240 sqmm to 400 sqmm

29747

395

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
CABLE TERMINATION 11 KV HT (HEAT SHRINKABLE)
M&L
Rs.

EACH
19202 Cable jointing kit for 11 KV (Earthed) grade
cable for indoor termination heat shrink
type joint complete with jointing material
and accessories suitable for 3 core XLPE
armoured aluminium conductor cable of

size 16 sqmm to 35 sqmm

6122

19203 Ditto, but 50 sqmm to 95 sqmm

6979

19204 Ditto, but 120 sqmm to 185 sqmm

8264

19205 Ditto, but 240 sqmm to 300 sqmm

8647

19206 Ditto, but 400 sqmm

9358

19207 Cable jointing kit for 11 KV (Earthed) grade


cable for outdoor termination heat shrink
type joint complete with jointing material
and accessories suitable for 3 core XLPE
armoured aluminium conductor cable of

size 16 sqmm to 35 sqmm

9912

19208 Ditto, but 50 sqmm to 95 sqmm

11154

19209 Ditto, but 120 sqmm to 185 sqmm

12264

19210 Ditto, but 240 sqmm to 300 sqmm

13465

19211 Ditto, but 400 sqmm

14160

19212 Cable jointing kit for 11 KV (Earthed) grade


cable for straight through heat shrink type
joint complete with jointing material and
accessories suitable for 3 core XLPE
armoured aluminium conductor cable of

size 16 sqmm to 35 sqmm.

12738

19213 Ditto, but 50 sqmm to 95 sqmm

14258

19214 Ditto, but 120 sqmm to 185 sqmm

18138

19215 Ditto, but 240 sqmm to 400 sqmm

19831

396

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
PRECAST CONCRETE CABLE COVERS
iwoZ fufeZr dahV dsoy vkoj.k
EACH

19216Supplying and laying reinforced precast


concrete cable cover, class EHV, type 1

with peak, size 450mm x 230mm x 50mm

M&L
lkexzh
,oa Je
Rs.

51.00
19217Ditto but class EHV type 2 with peak, size
62.00
600mm x 230mm x 50mm
19218Supplying and laying un-reinforced precast
concrete cable cover, class HVP, type 1 with

peak, size 300mm x 180mm x 40mm

38.00
19219Ditto, but type 2 with peak, size 450mm x
45.00
180mm x 40mm
19220Ditto, but class HV, Type 1, flat, size
38.00
300mmx l80mm x 40mm
19221Ditto, but Type 2, flat, size 450mm 180mm

x 40mm
43.00
19222Ditto, but Class LV, Type I, flat, size 250
33.00
mm x 150mm x 40mm

Laying
only
dsoy
fcNkuk
Rs.
7.00
14.00

7.00
14.00
7.00

14.00
7.00

19223Ditto, but Type 2, flat, size 300mm x 180mm


42.00
x 40mm

10.00

19224Ditto, but Type 3, flat, size 450mm x


48.00
l80mmx40mm

17.00

iz R ;s d

19216
19216vkiwfrZ o fcNkou] izofyr iwoZ fojfpr dahV dsoy
vkoj.k] Js.kh EHV uewuk 1 f'k[kj ds lkFk vkdkj
45023050 feeh
19217
19217mi;qZDr] Js.kh EHV uewuk 2 f'k[kj ds lkFk]
vkdkj 60023050 feeh
19218
19218dsoy vizcfyr dh vkiwfrZ rFkk yxkuk vkdkj
30018040 feeh ds ,p oh ih uewuk&1 ds 'kh"kZ
vizofyr iwoZ fufeZr dahV
19219
19219mi;qDZ r] fdUrq vkdkj 45018040 feeh uewuk&2
f'k[kj okys
19220
19220mi;ZqDr] fdUrq vkdkj 30018040 feeh ,p oh
Js.kh o uewuk&1] likV
19221
19221mi;qDZ r] fdUrq vkdkj 45018040 feeh uewuk&2
ds likV
19222
19222mi;qZDr] fdUrq 25015040 feeh] ,y oh Js.kh
uewuk&1] likV
19223
19223mi;qDZ r] fdUrq vkdkj 30018040 feeh uewuk&2
likV
19224
19224mi;qDZ r] fdUrq vkdkj 45018040 feeh uewuk&3
likV

397

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
PVC UNDERGROUND CABLE
ihohlh ds Hkwfexr dsoy
PER RUNNING METRE
19225PVC insulated, armoured,
heavy duty electric cable with
aluminium conductor, 1100
volts grade, cross-sectional area

25 sq. mm
19226Ditto, but sec. area 35 sq. mm
19227Ditto, but sec. area 50 sq. mm

Materials & labour


lkexzh ,oa Je
2 core 3 core 3 core 4 core
Rs.
Rs.
Rs.
Rs.

119
147
192

19228Ditto, but sec. area 70 sq. mm


19229Ditto, but sec. area 95 sq. mm
19230 Ditto, but sec. area 120 sq. mm
19231 Ditto, but sec. area 150 sq. mm
19232 Ditto, but sec. area 185 sq. mm
19233 Ditto, but sec. area 240 sq. mm
19234 Dillo, but sec. area 300 sq. mm
19235 Ditto, but sec. area 400 sq. mm
19236 Ditto, but sec. area 500 sq. mm
19237Ditto, but sec. area 625/630

sq. mm
PER RUNNING METRE
19238XLPE insulated, armoured
heavy duty electric cable with
aluminium conductor, 1100
volts grade, cross-sectional area

4 sq. mm
19239Ditto, but sec. area 6 sq. mm

19240Ditto, but sec. area 10 sq. mm

19241Ditto, but sec. area 16 sq. mm

19242Ditto, but sec. area 25 sq. mm

19243Ditto, but sec. area 35 sq. mm

19244Ditto, but sec. area 50 sq. mm

19245Ditto, but sec. area 70 sq. mm

19246Ditto, but sec. area 95 sq. mm

19247 Dillo, but sec. area 120 sq. mm

19248Ditto, but sec. area 150 sq. mm

19249Ditto, but sec. area 185 sq. mm

19250 Ditto, but sec. area 240 sq. mm

19251 Ditto, but sec. area 300 sq. mm

19252 Ditto, but sec. area 400 sq. mm

19253 Ditto, but sec. area 500 sq. mm


19254Ditto, but sec. area 625/630

sq. mm
19255 - 19267

150
172
226
271
331
399
460
523
675
802
992
1382

157
194
245
295
371
444
499
592
751
946
1208
1574

1731

1979

181
211
270

Materials & labour


lkexzh ,oa Je
2 core 3 core 3 core 4 core
Rs.
Rs.
Rs.
Rs.

68
97
104
113
125
152
195

86
111
122
135
166
211
265
346
427
518
628
765
989
1212
1523
1922

197
231
305
401
494
632
721
893
1143
1400
1761
2219

2503

2840

105
124
128
160
207
257
337

iz f r ehVj
19225
19225fo|qr jks/kd ih oh lh ls vkjf{kr Hkkjh
lsok ds fo|qr dsoy lkFk esa vYeksfu;e
lapkyd] dksfV 1100 oksYV ifjPNsnh dkV
{ks= 25 ofeeh
19226
19226mi;qZDr] fdUrq dkV {ks= 35 ofeeh
19227
19227mi;qZDr] fdUrq dkV {ks= 50 ofeeh
19228
19228mi;qZDr] fdUrq dkV {ks= 70 ofeeh
19229
19229mi;qZDr] fdUrq dkV {ks= 95 ofeeh
19230
19230mi;qZDr] fdUrq dkV {ks= 120 ofeeh
19231
19231mi;qZDr] fdUrq dkV {ks= 150 ofeeh
19232
19232mi;qZDr] fdUrq dkV {ks= 185 ofeeh
19233
19233mi;qZDr] fdUrq dkV {ks= 240 ofeeh
1 9234
9234mi;qZDr] fdUrq dkV {ks= 300 ofeeh
19235
19235mi;qZDr] fdUrq dkV {ks= 400 ofeeh
19236
19236mi;qZDr] fdUrq dkV {ks= 500 ofeeh
19237
19237mi;qDZ r] fdUrq dkV {ks= 625@630 ofeeh

398

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
PVC UNDERGROUND CABLE
ihohlh ds Hkwfexr dsoy tkjh
iz f r ehVj

PER RUNNING METRE

Materials &
labour
lkexz
h ,oa Je
19268XLPE insulated, screened, PVC bedded,
3core
3 dksj
galvanised steel strip or wire armoured,
Rs.
electric power cables (heavyduty) with
aluminium conductor, 11000 volts, grade

cross sectional area 25 sq. mm


497.00
19269Ditto, but sec area 35 sq. mm
19270Ditto, but sec. area 50 sq. mm
19271Ditto, but sec. area 70 sq. mm
19272Ditto, but sec. area 95 sq. mm
19273Ditto, but sec. area 120 sq. mm
19274Ditto, but sec area 150 sq. mm
19275Ditto, but sec. area 185 sq. mm
19276Ditto, but sec. area 240 sq. mm
19277Ditto, but sec area 300 sq. mm
19278Ditto, but sec area 400 sq. mm

572.00
647.00
773.00
917.00
1045.00
1185.00
1374.00
1689.00
1996.00
2352.00

19268
19268,Dl ,y ih bZ fo|qr jks/kd ls fyiVs ihohlh fcNk;s
tLrh yksgs dh ifk;kssa ;k rkj ls etcwrh ls cka/kh
lajf{kr fo|qr 'kfDr dsoy xq: dk;Z lkFk esa
vYeksfu;e lapkyd dksfV 11000 oksYV] ksfed ifjPNsnh
dkV {ks= 25 ofeeh
19269
19269mi;qZDr] fdUrq dkV {ks= 35 ofeeh
19270
19270mi;qZDr] fdUrq dkV {ks= 50 ofeeh
19271
19271mi;qZDr] fdUrq dkV {ks= 70 ofeeh
19272
19272mi;qZDr] fdUrq dkV {ks= 95 ofeeh
19273
19273mi;qZDr] fdUrq dkV {ks= 120 ofeeh
19274
19274mi;qZDr] fdUrq dkV {ks= 150 ofeeh
19275
19275mi;qZDr] fdUrq dkV {ks= 185 ofeeh
19276
19276mi;qZDr] fdUrq dkV {ks= 240 ofeeh
19277
19277mi;qZDr] fdUrq dkV {ks= 300 ofeeh
19278
19278mi;qZDr] fdUrq dkV {ks= 400 ofeeh

STREET LIGHT FITTINGS


ekxZ izdk'k O;oLFkk miLdj
(a) The rales for item 19279 to 19283 include the cost of
assembling of the complete fitting and its testing before
and after mounting or erection etc. for proper functioning,

(b) The rules however do not include the cost of G.I. pipe bracket,
bracket mounting clamp, bolts and nuts, line connector or
terminal/junction boxes and wiring from the fitting to the
overhead line or junction box as the case may be and shall be
measured and paid separately under appropriate section or
item unless otherwise indicated and cost thereof added to the
items.

[k

EACH
19279Fixing only street light fitting, for 70/80 watt
vapour or sodium vapour lamp, complete
with ballast and capacitor comprising of cast
aluminium housing, a pair of aluminium
reflectors, a highly transparent clear acrylic
cover hinged to the canopy at one end and
fixed by means of single spring action at the
other, suitable for mounting on 40mm or
50mm dia. G.I. mast or bracket arms with

pole fixing attachments and fixing of lamp


19280Ditto, but suitable for 125/150 walt and ditto

Rs.

82.00
98.00

19279 ls 19283 rd dh enksa esa lewps vo;oksa dk leqfpr


la;kstu djus dh ykxr rFkk leqfpr dk;Z'khyrk gsrq yxkus
ls igys o yxkus ds ckn mudh tkap djuk 'kkfey gSA
rksHkh] tLrh yksgs ds uy] dks"Bd] dks"Bd ij yxkus dh
ifj;k dkoys o f<ofj;ka ykbu la;kstd ;k lhekar@laxe
isfV;k rFkk vklatu ls ijh ykbu ;k laxe isfV;ksa rd
tSlh Hkh fLFkfr gks] dh rkj dh ykxr njksa esa 'kkfey ugha gSA
rFkk lacfa /kr [kaM ;k nj ds vaUrxZr izFkd eki rFkk Hkqxrku
gksxk tc rd dh vU;Fkk lwfpr u gks o budh ykxr enksa
esa tksM+ u yh xbZ gksA
iz R ;s d
19279
19279dsoy LFkkiu ekxZ izdk'k vklatu gsr]q 70@80 okV
edZjh ok"i ;k lksfM;e ok"i ofk;ka] 'kfDr o lkeF;Z
iw.kZ] <ys vYeqfu;e vkoj.k] ,d tksMk+ vYeqfu;e
ijkorZd ,d 'kfDr'kkyh ikjn'khZ Li"V vp+h;
vkoj.k ,d vksj ls Nrjh ls yVdh rFkk nwljh vksj
,dy dekuh ls tqMh+ ] tLrh yksgs ds 40 feeh ;k 50
feeh O;kl ds eLrwy ;k czfS dV Hkqtk ij yxkus ;ksX;]
[kaHks LFkkiu la;kstu o oRrh yxkus lfgr

19280
19280mi;qDZ r] fdUrq 125@150 okV ds mi;ZDq r rFkk mi;ZDq r

399

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
STREET LIGHT FITTING
ekxZ izdk'k O;oLFkk miLdj tkjh
iz R ;s d

Rs.

EACH
19281 Fixing only street light fitting suitable for 2
Nos. 40 watts fluorescent tubes, complete with
two ballasts and capacitor comprising of
aluminium, (stove enamelled, grey) canopy
aluminium gear tray (carrying ballasts,
capacitor, lamp holders, starters and starter
holder) plastic cover of highly transparent,
clear acrylic material fixed to canopy by
spring loaded hooks complete with G.I. pipe

mounting bracket & fixing with tubes


19282 Ditto but suitable For 2 Nos. 20 watts tube

lights and ditto


19283 Fixing only, post top lantern type external
light fitting complete including wiring from
junction box to the fitting (earthwork. G.I.
pipe post, P.C.C. and junction box with cut
out/fuse to be measured separately)

19281
19281dsoy LFkkiu] ekxZ izdk'k vklatu] ds mi;qDr gsrq
40 okV dh 2 QyksjhlsV V;wc] 2 'kfDr o lkeF;Z
vYeksfu;e xSl eqyEekf;r Hkwjh vkoj.k vYeksfu;e
midj.k/kkjh cYkkLV lkeF;Z ySai/kkjd izLFkud o
izLFkkud /kkjd ds lkFk] vR;f/kd ikjn'kZd IykfLVd
vkoj.k la;Dq r yVdrs dkaVs ls tqMh+ rFkk tLrh yksgs
ds uy ij yxh dks"Bd o V;wc ls tksM+us lfgr
65.00
65.00

65.00

19282
19282mi;qZDr] fdUrq 20 okV 2 V;wc okh ds fy, mi;qZDr
rFkk mi;qZDr
19283
19283dsoy LFkkiu [kaHks dh ijh ykyVsu fdLe ls ckgjh
izdk'k la;kstu yxkuk ftlesa laxe cDlsls la;kstu
feh dk;Z] tLrh yksgs ds uyh; [kaHks] izofyr lhesVa
dahVo laxe cDls lfgr rksMd
+ @Q;wt lfgr yxkuk
tks izFkd ekis tk;saxsA

SYNTHETIC INSULATING MAT

EACH

M&L
Rs.

19284 Ditto, but of size 2m x lm x 10 mm

2,000

19285 Ditto, but of size 2m x lm x 12 mm

2,500

19286 Ditto, but of size 2m x lm x 19 mm

4,000

19287 Ditto, but of size 2m x lm x 25 mm

5,000

400

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
HIGH MAST LIGHT

Materials & labour


lkexzh ,oa Je

EACH
19288 High galvanized mast light
suitable for 6 to 9 lantern
symmetrically fitted along
with their control gear and
having two point suspension
system with stainless steel
wire rope of 6 mm dia 97/19
guage and double drum
winch with luminaire
mounting
arm,
pully
assembly, aviation obstruction
light, lightning arrester spike
including RCC foundation as

per height.

15 Meter

20 Meter

30 Meter

Rs.

Rs.

Rs.

270500

360500

540500

DISMANTLING
m[kkM+ u k
POLES AND STRUTS
EACH

19289 Dismantling wood poles/

struts, any size

Dismantling and Transporting


setting aside for re- to store and
use within 50 metres
stacking
m[kkM+uk o fQj yxkus
Hk.Mkj ys
gsrq 50 eh- ds vUnj
tkus o ps
ps yxkuk
lfgr
Rs.
Rs.
39.00

130.00

19290 Dismantling concrete


poles/ struts, any size

310.00

391.00

19291 Dismantling steel poles/

struts, any size

209.00

310.00

19292

[kaHks vkSj LrEHk


iz R ;s d

19289
19289ydM+h ds fdlh Hkh vkdkj ds [kaHkks@
a LrEHkksa
dks m[kkM+uk
19290
19290dahV ds fdlh Hkh vkdkj ds [kaHkks@
a LrEHkksa
dks m[kkM+uk
19291
19291yksgs ds fdlh Hkh vkdkj ds [kaHkks@
a LrEHkksa
dks m[kkM+uk
19292

401

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
DISMANTLING Contd...
m[kkM+uk tkjh
CROSS ARMS

Rs.

dS a f ppk

PER QUINTAL

iz f r fDoa V y

19293 Dismantling cross-arms of M.S. channel or


angle sections etc. complete and setting aside

for re-use with in 50m

19293
19293uje yksgs dh uyh ;k lyk[k vkfn dh dSafp;ksa dks
iw.kZr% m[kkM+uk rFkk iqu% iz;ksx gsrq 50 eh ds vUnj ,d
vksj pk yxkuk

31.00

INSULATORS

fo|q r vojks / kd

EACH

iz R ;s d

19294Dismantling insulators any type, any size

19294
19294fdlh Hkh uewus o fdlh vkdkj ds fo|qr vojks/kdksa dks
m[kkM+uk rFkk mi;qZDr djuk

16.00

LFkki la ; ks t u
izfr lewg

STAY ASSEMBLY
PER SET
19295 Dismantling stay assembly complete.
(demolition of concrete, etc. and excavation

measured separately)

65.00

19295
19295laiw.kZ LFkki la;kstu dks vyx djuk rFkk mi;qZDr
djuk dahV vkfn dh rqM+kbZ vkSj [kqnkbZ izFkd ekih
tk;sxh

CONDUCTORS

la p kyd

PER QUINTAL

iz f r fDoa V y

19296Dismantling earth wire or copper conductor,

service feeder or distributor span

65.00

19297Dismantling of ACSR or AAC conductors

82.00

19296
19296Hkw;kstu rkj ;k rkacs ds lapkyd] lsok iks"kd ;k forjd
foLrkj dks fudkyuk
19297
19297, lh ,l vkj ;k , , lh lapkydksa dks fudkyuk rFkk
mi;qZDr

BRACKETS

dks " Bd

EACH

iz R ;s d

19298Dismantling house service brackets, any type

19299Add to item 19298 for making good


disturbed work, if brackets are not to be re
fixed at the same place
19300Dismantling air break gang operated switches
vertical/horizontal mounted including
insulators and operating mechanism for
repair/ replacement of broken/worn out
components and insulators etc. or carrying to
MES store (spare/components for replacement

to be provided free by department)


19301Dismantling and taking down fluorescent
tube light single/double of any wattage or
size street light fittings for repair or
replacement of burnt/worn out accessories
or carrying to MES store (Accessories or
components to be provided free for

replacement by department)

33.00

13.00

185.00

67.00

19298
19298fdlh uewus dh xzg lsok dks"Bdksa dks m[kkM+uk rFkk
mi;qZDr djuk
19299
19299en 19298 esa tksM]as ;fn dks"Bdksa dks mlh LFkku ij fQj
ls ugha yxkuk gS rks fcxM+s LFkku dks Bhd djus ds fy;s
19300
19300ok;qjks/ku lewg lapkfyr lh/ks@lekukUrj yxs fctyh
ds cVuksa dks /kkjk vojks/kd o lapkyu ;kaf=dh lfgr(
VwVs gq,@ csdkj vaxksa o fo|qr vojks/kd dh ejEer
djus iqu% LFkkfir djus ds fy, ;k Hk.Mkj esa ys tkus
ds fy, fudkyuk iqu% LFkkiu ds fy, vo;oksa@vaxksa
dh O;oLFkk foHkkx }kjk fu%'kqYd dh tk;sxh
19301
19301fdlh Hkh fo|qr 'kfDr ; vkdkj dh lM+d jks'kuh ds
la;kstu dh ltkoVh ,dy ;k nksgjh ltkoVh fctyh
dh V~;wc uyh dks] tys gq,@csdkj gks x;s lgk;d
vo;oksa dh ejEer djus ;k Hk.Mkj esa ys tkus ds fy,
fudkyuk iqu% LFkkiu ds fy, lgk;d vo;oksa ;k vaxksa
dh O;oLFkk foHkkx }kjk fu%'kqYd dh tk;sxh

402

SECTION 19

SECTION 19ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
SUB SECTION B-INTERNAL WORK
mi[kaM o vUrjhZ; dk;Z
POINT WIRING

fcUnq rkj iz c U/k

(I) The rates for point wiring include:


(a) Supplying and fixing/drawing of cables for carrying
out wiring of a circuit of any length from the
distribution board or iron clad switch unto ceiling
rose or connector, socket outlet, lamp holder, switch
or fan regulator including additional length from
connector to lamp holder (in case of stiff pendant
points and water tight bracket points) and back plate
to lamp holder (in case of plain bracket points).
(b) Supplying and fixing in case of conduit casing &
caping wiring all conduits/casings & capings
(separate conduits/caring & capings for individual
conduit casing caping circuits) or conduit casingd
caping fittings and accessories, joint boxes, terminal
boxes for mounting or housing switches, socket
outlets, fan regulators, etc. and continuous earthing
and earthing connections, all as specified.
(c) Supplying and fixing wood battens, bends, corners,
filters, tee-pieces, etc. required for wiring on battens.
(d) Supplying and fixing all accessories such as screws,
clips, plugs, clamps, etc. as specified for securing
cables, battens, conduits etc. to walls, steel joists etc.

1 fcUnq rkj izcU/k dh njksa esa 'kkfey gSa%


d forj.k cksMZ ;k yksgs <dh cVu ls Nr dh pkbZ;k la;kstd dks"Bd
fudkl] ySai gksYMj] ;k ia[ks ds fu;ked rd ,d eaMyh; {kkjk izokg
ls fdlh Hkh yEckbZ rd rkj ys tkus ds fy,] la;kstuksa ls ySi
gksYMj rd dh vfrfjDr yECkkbZ lfgr dscyksa dh vkiwfrZ djuk rFkk
yxkuk dBksj yEcku fcUnq ;k ty dBksjhd`r czSfdV fcUnq ds ekeys
esa rFkk ySEi gksYMj dh iz"B IysV lknk cSzfdV fcUnq ds ekeys esa

(e) Supplying and fixing PVC or steel conduits for


mechanical protection of cables as specified.
(f) Supplying and fixing bushed conduits or porcelain
tuning, as specified, for wiring to pass through walls,
floors etc.
(g) Supplying and fixing all wood blocks and boards,
sunk or surface type, including those required for
mounting fan regulators.
(h) Supplying and fixing joint or junction-boxes and
connecting the same as ordered in case of batten wiring.
(j) Supplying and fixing earth wire and earthing
connections, as specified, including all accessories
required for the same.
(k) Supplying and fixing/drawing separate neutral wire
for each individual circuit from the distribution
board (or iron clad in lieu).
(I) Cutting holes in or through walls, taking up and refixing floor boards, notching or drilling holes
through joints and making good all disturbed work
to match the existing.
(m) Shellac varnishing as specified, to wood battens,
wood blocks and other wood fittings and fixtures.
(n) Painting of battens and cables or surface conduits
alongwith the painting of walls.
(o) Testing, as specified.
(p) Providing coloured tapes on cable/wire ends in
terminal boards/boxes for colour coding purpose
in case of single insulation colour of cable/wire for
batten wiring on surface.
(q) Any difference of cost of cables of different insulation
colour for colour coding in case of conduit wiring.

[k uyh;@dsflax o dsfiax rkj O;oLFkk ds fo"k; esa lHkh ufy;ka@dsflax


o dsfiax izR;sd O;fDrxr /kkjk ds fy, vyx&vyx ufy;ka@dsflax
o dsfiax ;k {kkjk izokg ds la;kstd o vo;o] la;kstd isfV;ka
vUrh; cDls] yxkus ds fy, ;k xzg cVu] dks"Bd fudklksa] ia[kksa ds
fuxeksa vkfn rFkk vuojr Hkw;kstu o Hkw;kstu la;kstuksa lHkh funs'kkuqlkj
dh viwfrZ djuk rFkk yxkukA
x ydM+h dh ofY;ks]a eksM] fdufj;ka] iwjdks]a Vh [kaM vkfn] ftudh cfYy;ksa
ij rkj O;oLFkk esa vko';drk gksrh gS]a dh vkiwfrZ djuk rFkk yxkukA
?k lHkh la;kstu lkexzh tSls] isp] if;ka vkfn dscyksa] cfYy;ksa /kkjk
izokgd iFkksa dh lqj{kk ds fy;s tSlk fufnZ"V gS vkfn ls yksgs ds
nhokj rd la;kstd vkfn dh vkiwfrZ djuk rFkk yxkukA
M ihohlh ;k yksgs dh ufy;ksa dh ;kf=d lqj{kk gsrq tSlk fufnZ"V gks
dh vkiwfrZ djuk rFkk yxkukA
p ?kqekonkj uyh ;k phuh feh dh uyh] fufnZ"Vkuqlkj nhokjksa
Q'kksZ vkfn esa ls rkj ys tkus ds fy;s] dh vkiwfrZ djuk rFkk
yxkukA
N ydM+h ds lHkh [kkaps o rf[r;ka] <yoka ;k lrgh fdLe dh rFkk
ftudh ia[ks ds fu;kedksa dks yxkus esa vko';drk gksrh gS lfgr dh
vkiwfrZ djuk rFkk yxkukA
t cfYy;ksa ij rkj O;oLFkk ds fy, funsZ'kkuqlkj la;kstd ;k laxe
isfV;ka rFkk mu ds la;kstu dh vkiwfrZ djuk rFkk yxkukA
> Hkw;kstu rkj o Hkw;kstu fufnZ"Vkuqlkj rFkk mlds fy;s lHkh vko';d
lgk;d lkexzh dh vkiwfrZ djuk rFkk yxkukA
_ forj.k r[rs ls izR;sd O;fDrxr /kkjk izokgrkj ,d izFkd rVLFk
rkj dh vkiwfrZ djuk rFkk yxkuk@Mkyuk ;k mlds LFkku ij
vkojd fLopA
V nhokjksa esa ;k nhokj esa ls Nsn dkVuk] mBkuk rFkk iqu% Q'khZ r[rh
yxkuk] la;kstdkas nkrs ;k ojesa ls Nsn cukuk rFkk orZeku dk;Z ls
feykrs gq, fo?kVu dks Bhd djukA
B ydM+h dh cfYy;ksa ydM+h dh isfV;ksa rFkk vU; ydM+h la;kstu o
lkt leku ij fufnZ"Vkuqlkj piM+s dh okfuZ'k djukA
M cfYy;ksa rFkk dscyksas ;k lrgh ufy;ksa] lkFk dh nhokj ij jksxu
djukA
< fufnZ"Vkuqlkj tkap djukA
.k cfYy;ksa dh lrgh rkj O;oLFkk ds fy,] dscy@rkj ;k ,dy jax
O;oLFkk ds eNyh rsy ds feyku ds fy, varh; rf[r;ksa@isfV;ksa esa
dscy@rkj ds fdukjksa ij jaxhu isaV dh O;k[;k djukA
; uyh }kjk rkj O;oLFkk ds fo"k; esa eNyh ds rsy dh iqrkbZ o fHkUu
jax ds dscy dh jaxkbZ esa vkus okyh ewY; fHkUurkA

403

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
POINT WIRINGContd...
fcUnq rkj izcU/k tkjh
(2) The rates for point wiring do not include:

(a) Supplying and fixing wood blocks and boards


required for mounting distribution boards and ironclad switches.
(b) Supplying and fixing electric fittings and accessories
such as ceiling roses, lamp holders, pendants, socket
outlets, brackets, switches, shades, lamps, call bells
and buzzers etc.
(c) Cutting chases for conduits and sinking's for boxes
and making good to walls, floors etc. in case of recessed
or concealed conduit wiring.
(d) Supplying and fixing terminal boxes for power plugs,
fan regulators, switches, socket outlets, etc. fixed flush
to the wall as specified for surface wiring on wood
battens.
(e) Supplying and fixing submain earthing from main
switch control board to a distribution board.
(3) In case of surface wiring on wood battens, payment for
recessed terminal boxes for housing power plugs, fan
regulators, switches, socket outlets, etc. 'where ordered,
shall be made at the difference heiween the rates of the
terminal boxes and wood blocks.
PER POINT

Rs.

fcUnq rkj O;oLFkk dh njksa esa 'kkfey ugha gSa%


d ydM+h ds [kkaps o rf[r;ka ftudh yksgs dh e<h cVuksa
o forj.k rf[r;k yxkus esa vko';drk gksxh mudh
vkiwfrZ djuk rFkk yxkukA
[k fctyh dh la;kstd o lgk;d lkexzh tSls Nr ds
dVksjh] ckh gksYMj] yEcu] dksVj fudkl] dks"Bd]
fctyh ds cVu] fpeuh ySai] ?kaVh o ctj vkfn dh
vkiwfrZ djuk rFkk yxkukA
x ufy;ksa esa [kkaps o isfV;ksa esa fudkl dkVus rFkk tgka
rkj ufy;k nhokjksa] Q'kksZ esa vUnj Mkyh xbZ gksa ;k
yxkbZ xbZ gksa rFkk mudk Bhd djukA
?k 'kfDr MkVsa ia[kksa ds fu;ked] cVu] dksVj fudkl ds
vUrh; isfV;ka fufnZ"Vkuqlkj ydM+h dh cfYy;kas ij yxh
lrgh ckj O;oLFkk ds fy, iqu% nhokjksa esa yxkbZ xbZ gks
mudh vkiwfrZ djuk rFkk yxkukA
M- eq[;/kkjk izca/kd r[rh ls forj.k r[rh rd mieq[;
Hkwfe;kstu dh vkiwfrZ djuk rFkk yxkukA
ydM+h dh cfYy;ksa ij lrgh rkj O;oLFkk ds ekeys es]a 'kfDr
MkVsa ia[ks ds fu;ked] cVu dksVj fudkl vkfn ds fy, vkyksa
esa yxs varh; cDls tgka dgk x;k gks rks budk Hkqxrku varh;
cDls o ydM+h ds cDls ds ewY; ds vUrj dk gksxkA
izfr fcUnq

19302Taking down carefully copper/aluminium point


wiring (light, fan, socket or power) complete,
(fittings such as switches, ceiling roses,
pendants, regulators sockets etc. to be measured
separately), removing materials to store for keeping
in safe custody for reuse at site and making good

disturbed surfaces of walls, floors, etc.

19302
19302rkac@
s vYeqfu;e fcUnq rkj O;oLFkk cfk;ka ia[ks] dksVj
;k ikoj dks iw.kZr;k /;kuiwoZd fudkyuk] miLdj
tSls cVusa Nr dVksjh yEcku] fu;ked] dksVj vkfn
izFkd ekih tk;sxh iqu% iz;ksx ds fy, lqjf{kr j[kus
ds fy, lkexzh dks Hk.Mkj rd igqapkuk rFkk nhokj

Q'kksZ ds fo?kfVr LFkku dks laokjuk


70.50

19303Taking down copper/aluminium point wiring


(light, fan, socket or power) complete, including
fixture and fittings such as switches, ceiling
roses, pendants, regulators, sockets, light fitting etc.
removing materials to store for keeping in safe custody
or for taking credit (credit for above items should be
made as per conditions separately) and making
good disturbed surfaces of walls, floors, etc.

47.00

19304Taking down carefully by unscrewing from boards/


outlet boxes, fittings and fixtures such as switches,
sockets, ceiling roses, lamp holders, brackets, ceiling
fittings, bulk head fittings, tube light fittings and
regulators, etc. for reuse at site or carrying to the
store (To be measured only when found serviceable

in all respects complete for reuse)

7.30

19304 cksMksZ@fudklh cDlksa] vklatuksa o lTtkvksa esa ls /


;ku iwoZd fudkyuk] tSls cVusa] dksVj] lhfyx jkst]
ySEi gksYMj] 'kh"kZ miLdj] fo|qr ufy;ksa ds miLdj
rFkk fu;ked vkfn dks LFkku ij iqu% iz;ksx ;k Hk.Mkj
ys tkuk rHkh ekih tk;sx
a h tc mUgsa iqu% iz;ksx djus
;ksX; ik;k tk;sxk

404

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
POINT WIRINGContd...
fcUnq rkj izcU/k tkjh
EACH

19305

19306

19307

19308

Wiring with copper


conductor cables
In stove ena- In PVC
melled Steel Conduit
Conduit

PVC Labour PVC


single only single
core,
core,
shea
shea
thed
thed
cable
cable
One light M & L
M&L
point or one
fan point
controlled
by
one
switch with
cables 1.5 sq. Rs.
Rs.
Rs.
mm size 650.00 264.60 509.10
Ditto, with
cables 2.5 sq.
mm size 722.30 264.60 580.20
Add to item
3318 for each
additional
light point
on the same
switchcircuit
322.80 158.70 242.10
Add to item
3318A for
ditto
362.00 158.70 281.30

vYeqfu;e dsoy lapkyd rkj O;oLFkk


In stove enamelled
steel conduit

bYkkfLVd e<+h
e<+h
dscy
dscy lk lk o
o Je
Je

241.50

In PVC conduit

ihohlh uyh esa

eqyEoh bLikr uyh esa

Labour Elasto- PVC Labour


only
mer
shea- only
shea- thed dsoy
thed
cable Je
cable M & L
M & L ihohlh

Rs.
241.50

izfr fcUnq

Wiring with Aluminium conductor cables

Rs.
429.90

450.80

Elasto- PVC Labour


mer
shea- only
shea- thed dsoy
thed cable
Je
cable M & L
M & L ihohlh

bykfLVd e<+h
e<+h
dscy
dscy lk lk o
o Je
Je

Rs.
Rs.
422.30 170.10

442.00 174.50

Rs.
320.10

339.90

Rs.
Rs.
312.60 174.50

331.10 174.50

19305 ,d ckh fcUnq


;k ,d ia[kk
fcUnq cVu ls
fu;af=r LkkFk esa
1-5 ofeeh
vkdkj dh rkj

19306 mi;qZDr] 2-5


ofeeh rkj
19307 tksMas+ en 3318
eas mlh ldZV
ij vfrfjDr
fcUnq ds fy;s

132.30

223.80

220.00

96.10

168.90

165.10

96.10

132.30

234.20

229.80

96.10

178.80

174.40

96.10

19309 One light


point controlled by two
2 - w a y
switches,
with cables
1.5 sq. mm
939.50 291.00 716.90 267.90
size

597.30

561.70 197.70

432.10

420.90 197.70

19308 tksMas+ en 3318


esa mi;qZDr ds
fy;s
19309 ,d okh fcUnq
nks f}/kkjk fLop
ls fu;af=r] 1-5
ofeeh vkdkj
dh rkj

405

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
POINT WIRINGContd...
fcUnq rkj izcU/k tkjh
PER POINT
Table Contd...
19310 Ditto,
with
Rs.
Rs.
Rs.
cables 2.5 sq.
mm size
1070.30 291.00 847.70
19311 One 3 pin
socket outlet 5
amps on the
same board
with
other
switches, with
cables 1.5 sq.
mm size
84.00
69.40 84.00
19312 Ditto,
with
cables 2.5 sq.
mm size 91.80 69.40 91.80
19313 One 3 pin
socket outlet, 5
amps, independent, with
cables 1.5 sq.
mm size
650.00 264.60 509.10
19314 Ditto,
with
cables 2.5 sq.
722.20 264.60 580.20
mm size
19315 One 3 pin 5
amps socket
outlet independent but below
the switch board
of light points in
the same vertical
plane,
with
cables. 1.5 sq.
mm size
260.70 125.70 208.90
19316 Dilto,
with
cables 2.5 sq
286.80 125.70 235.00
mm size
19317 One
bell/
buzzer p o i n t
controlled by
one
push
button on the
same board with
other switches
or independent
with cables
1.5 sq.mm size 650.00 264.60 509.10
19318 Ditto.
with
cables 2.5 sq.
722.20 264.60 580.20
mm size
19319 One 3 pin socket
outlet. 15 amps,
independent,
with cables 4 sq.
mm size
1203.60 317.50 990.00

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

267.90 162.50 665.00 615.60 197.80 461.00 448.30 197.80

izfr fcUnq
19310
19310mi;qZDr fdUrq 2-5
ofeeh dk rkj

19311
19311,d 3 fiu lkdsV
5 ,Ei dh nwljh
fLopksa ds lkFk mlh
cksMZ ij] 1-5 ofeeh
dh rkj ds lkFk
69.40 29.10

89.40

88.10

43.70

70.10

68.40

43.70

69.40 29.10

93.10

91.60

43.70

73.30

71.70

43.70

19312
19312mi;qDZ r] fdUrq 2-5
ofeeh dh rkj

19313
19313,d 3 fiu lkdsV
fudkl 5 ,Ei]
vdsyh] 1-5 ofeeh
rkj ds lkFk
241.50 116.30 429.90 422.30 174.50 320.10 312.50 174.50

241.50 116.30 450.80 442.00 174.50 340.10 331.10 174.50

19314
19314mi;qZDr fdUrq 2-5
ofeeh rkj ds lkFk

19315 ,d 3 fiu lkdsV


fudkl 5 ,Ei
vdsyh] fdUrq ckh
ds cksMZ ds uhps
lekukUrj] 1-5
ofeeh vkdkj ds
rkj ds lkFk
99.20 43.70 148.40 145.90

65.40 112.00 109.60

65.40

99.20 43.70 153.80 151.00

65.40 118.30 115.50

65.40

241.50 116.30 429.90 422.30 174.50 320.10 312.50 174.50

241.50 116.30 450.80 442.00 174.50 339.90 331.10 174.50

281.10 174.50 679.00 666.00 209.40 507.80 494.80 209.40

19316
19316mi;qZDr] fdUrq 25 ofeeh ds rkj ds
lkFk
19317
19317,d ?kaVh@ctj fcanq
,d iq'k cVu ls
fu;a f =r nw l jh
cVuksa ds lkFk mlh
cksMZ ij ;k vdsyk]
1-5 ofeeh dh rkj
ds lkFk

19318
19318mi;qDZ r] fdUrq 2-5
ofeeh dh rkj ds
lkFk
19319
19319,d 3 fiu lkdsV
15 ,Ei fudkl
vdsyh 4 ofeeh
vkdkj rkj ds lkFk

406

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19&fo|qr dk;Z
POINT WIRINGContd...
fcUnq rkj izcU/k tkjh
PER POINT

PVC sheathed cable


M&L
19320 One light point or one fan
point
controlled by one
switch with
cables 1.5 sq.
mm size

19321 Ditto, with cables 2.5 sq. mum


size

19322 Add to item 3324A for each


additional light point on the
same switch circuit
19323 Add to item 3324B for ditto
19324 One light point controlled by
two 2-way switches, with
cables 1.5 sq. mm size
19325 Ditto,with cables 2.5sq. mm
size

19326 One 3 pin socket outlet, 5


Amps on the same board with
other switches, with cables 1.5
sq. mm size

19327 Ditto, with cables 2.5 sq. mm


size

19328 One 3 pin socket outlet, 5


Amps, independent, with
cables 1.5 sq. mm size
19329 Ditto, with cables 2.5 sq. mm
size

19330 One 3 pin 5 Amps socket


outlet independent but below
the switch board of light points
in the same vertical plane, with
cables, 1.5 sq. mm size
19331 Ditto, with cables 2.5 sq mm

size
19332 One bell/ buzzer point
controlled by one push button
on the same board with other
switches or independent with

cables1.5 sq.mm. size


19333 Ditto, with cables 2.5 sq. mm

size
19334 One 3 pin socket outlet, 15
Amps, independent, with

cables 4 sq. mm size

izfr fcUnq

Wiring with Copper conductor


cables in PVC casing & caping
Labour
only

ihohlh
e<+h dosy

dscy
Je

Rs.

Rs.

369.90

122.40

19320

19321
122.40

223.50

112.40

262.70

112.40

19323
19324

565.00

158.70

699.30

158.70

19322

19325

19326
69.40

91.80

69.40

19327

19328
369.90

122.40

448.30

122.40

19329

19330

185.10

89.30

211.20

89.30

19331

19332
369.90

122.40

448.30

122.40

19333

19334
896.80

201.70

mi;qZDr] 2-5 ofeeh rkj

448.30

84.00

,d ckh fcUnq ;k ,d ia[kk fcUnq


cVu ls fu;af=r lkFk esa 1-5 ofeeh
vkdkj dh rkj

tksM+sa en 3324, esa mlh ldZV


ij vfrfjDr fcUnq ds fy;s
tksM+sa en 3324ch esa mi;qZDr ds
,d ckh fcUnq nks f}/kkjk fLop ls
fu;af=r] 1-5 ofeeh vkdkj dh
rkj
mi;qZDr] fdUrq 2-5 ofeeh dk
rkj
,d 3 fiu lkdsV 5 ,Ei dh
nwljh fLopksa ds lkFk mlh cksMZ
ij] 1-5 ofeeh dh rkj ds lkFk
mi;qZDr] fdUrq 2-5 ofeeh dh
rkj
,d 3 fiu lkdsV fudkl 5 ,Ei]
vdsyh] 1-5 ofeeh rkj ds lkFk
mi;qZDr] fdUrq 2-5 ofeeh rkj ds
lkFk
,d 3 fiu lkdsV fudkl 5 ,Ei
vdsyh] fdUrq ckh ds cksMZ ds
uhps lekukUrj] 1-5 ofeeh vkdkj
ds rkj ds lkFk
mi;qZDr] fdUrq 2-5 ofeeh ds rkj
ds lkFk
,d ?kaVh@ctj fcanq ,d iq'k cVu
ls fu;af=r nwljh cVuksa ds lkFk
mlh cksMZ ij ;k vdsyk] 1-5 ofeeh
dh rkj ds lkFk
mi;qZDr] fdUrq 2-5 ofeeh dh
rkj ds lkFk
,d 3 fiu lkdsV 15 ,Ei fudkl
vdsyh 4 ofeeh vkdkj ds rkj ds
lkFk

407

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
POINT WIRING-Contd...
fcUnq rkj izcU/k tkjh
PER POINT

izfr fcUnq

Wiring with stranded copper


conductor cables in PVC conduit
PVC
sheathed
cable
M&L

Labour
only

dsoy
Je

ihohlh
e<+h dscy
lk o Je
19335 One light point or one fan point
controlled by one switch with

cables 1.5 sq. mm. size


19336 Ditto, with cables 2.5 sq. mm.

size
19337Add to item 3324P for each
addition light point on the same

switch circuit
19338 Add to item 3324Q for ditto
19339 One light point controlled by two
2-way switches, with cables 1.5

sq. mm. size

19340Ditto, with cables 2.5 sq. mm size


19341 One 3 pin socket outlet 5 Amps
on the same board with other
switches, with cables 1.5 sq. mm

size
19342 Ditto, with cables 2.5 sq. mm

size
19343 One 3 pin socket outlet, 5 Amps,
independent. with cables 1.5 sq.

mm size
19344 Ditto, with cables 2.5 sq. mm

size
19345 One 3 pin 5 Amps socket outlet
independent but below the switch
board of light points in the same
vertical plane, with cables, 1.5 sq.

mm size
19346 Ditto, with cables 2.5 sq mm

size
19347 One bell/ buzzer point controlled
by one push button on the same
board with other switches or
independent with cables

1.5sq.mm size

Rs.

Rs.

224.00

105.80

300.00

105.80

146.00

92.60

185.00

92.60

323.00

119.00

451.00

119.00

116.00

82.70

19335 ,d ckh cUnq ;k ,d ia[kk fcUnq cVu


ls fu;af=r lkFk esa 1-5 ofeeh vkdkj
dh rkj
19336 mi;qZDr] 2-5 ofeeh rkj
19337 tksMsa+ en 3324ih esa mlh ldZV ij
vfrfjDr fcUnq ds fy;s
19338 tksMs+ en 3324d;w esa mi;qZDr ds
19339 ,d ckh fcUnq nks f}/kkjk fLop ls fu;af=r]
1-5 ofeeh vkdkj dh rkj
19340 mi;qZdr] fdUrq 2-5 ofeeh dk rkj
19341 ,d 3 fiu lkdsV 5 ,Ei dh nwljh
fLopksa ds lkFk cksMZ ij] 1-5 ofeeh dh
rkj ds lkFk
19342 mi;qZDr] fdUrq 2-5 ofeeh dh rkj

142.00

224.00

82.70

105.80

19343 ,d 3 fiu lkdsV fudkl 5 ,Ei]


vdsyh] 1-5 ofeeh rkj ds lkFk
19344 mi;qZDr fdUrq 2-5 ofeeh rkj ds lkFk

300.00

105.80

208.90

102.20

235.00

224.00

102.20

105.80

19345 ,d 3 fiu lkds V fudkl 5 ,Ei


vds y h] fdUrq okh ds cks M Z ds uhps
lekukUrj] 1-5 ofeeh vkdkj ds rkj ds
lkFk
19346 mi;qZDr] fdUrq 2-5 ofeeh ds rkj ds
lkFk
19347 ,d ?kaVh@ctj fcanq ,d iq'k cVu ls
fu;af=r nwljh cVuksa ds lkFk mlh cksMZ
ij ;k vdsyk] 1-5 ofeeh dh rkj ds lkFk

408

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
POINT WIRING-Contd...
fcUnq rkj izcU/k tkjh
PER POINT
19348 Ditto, with cables 2.5 sq. mm

size

Rs.

Rs.

300.00

105.80

19349 One 3 pin socket outlet, 15 Amps,


independent. with cables 4 sq. mm

size

672.00

142.20

izfr fcUnq
19348 mi;qZDr] fdUrq 2-5 ofeeh dh rkj ds
lkFk
19349 ,d 3 fiu lkdsV 15 ,Ei fudkl
vdsyh 4 ofeeh vkdkj rkj ds lkFk

CAST IRON/PRESSED STEEL TERMINAL BOXES

<ys yksgs@laihfMr bLikr varLFk cDls


EACH
19350 Cast Iron/
pressed steel
terminal
boxes 60 mm
deep
for
mounting,
switches,
sockets, fan
regulator, etc.
with 3mm
thick plastic
laminated
sheet cover

M&L
75mm x

100mm x

75mm

100mm

square
square
or 75mm or 100mm
dia
dia

150mm x 150mm x 175mm x

200mm x 200mm x 200mm x

75mm

150mm

100mm

150mm

250mm

300mm

rectangular

rectangular

rectangular

rectangular

rectangular

rectangular

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

68.70

90.80

104.80

137.30

22.10

165.20

209.70

246.60

iz R ;s d
19350 fctyh ds cVu]
dksVj ia[ksa ds
250mm x
fu;ked vkfn
300mm
rectands fy;s <ys
gular
yksgs@laihfMr
Rs.
bLikr ds varLFk
cDls] 3 feeh
eksVs IykfLVd ls
e<+h pknj ds
297.70
<Ddu lfgr

PENDANTS

iz y Ecu
19351Pendant ordinary, comprising ceiling
rose, brass with insulated body lamp
holder, cord grip pattern, and 0.5 sq.mm
copper flexible twisted twin cord up to

1.5m length as ordered


19352Double stiff pendants, comprising of
galvanised steel or chromium plated
brass bell mouth connectors 2 Nos.
with back plate and 21.50 metre long
parallel 20mm dia galvanised or stove
enamelled screwed steel conduit with
two check nuts for fixing tube light
fitting and upto 1.5 metre long twin
core 0.5 sq. mm copper conductor

flexible wire/cable
PER RUNNING METRE
19353Extra over ordinary pendants for
additional length of cable ordered

beyond 1.5m length


19354 Add or deduct to item 19352 for
adjustment of extra or less length of
conduit and flexible wire as ordered

M&L

Fixing only

lk- o Je

dsoy LFkkiu

Rs.

Rs.

68.60

18.50

283.90

43.80

19351
19351lk/kkj.k izyEcu ftlds lkFk Nr dh dVksjh
ihry dh uyhnkj ySEi gksYMj] idM+ fdLe
dh tathj rFkk 0-5 oxZ feeh dh rkacs dh
yphyh mPNhnkj nqgjh 1-5 eh rd dh yEch
vkKkuqlkj tathj yxh gks
19352
19352;qxy Bksl izycu ftlesa /kkrq p<+h bLikr
;k vY;qeksfu;e eqyEek;qDr ihry dh ?kaVh
eaqg la;kstd 2 ua- dkyh ih lfgr rFkk
21-50 eh yEch- lekukUrj 20 feeh O;kl
/kkrq p<+h ;k V;wc jks'kuh ds vo;oksa dks
yxkus gsrq vkSj 1-5 eh rd yEcs nksgjs fdukjs
0-5 ofeeh rka c s ds la p kyd yphyh
rkj@dsoy] yxh gks
iz f r ehVj

8.80

124.40

4.60

11.50

19353 vfrfjDr] vkKkuqlkj 1-5 eh- ls vf/kd yEch


dscy yxkus ds fy;s lk/kkj.k izyEcu ij
19354 en 19352 esa ls ?kVk;sa ;k tksMs+ vkKkuqlkj
de ;k vf/kd yEch uyh o yphys rkj ds
lek;kstu ds fy,

409

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
POINT WIRING-Contd...
fcUnq rkj izcU/k tkjh
FLUORESCENT TUBLE LIGHT FITTINGS/CFL FITTINGS/ FLAME PROOF FITTING

ltkoVh izdk'k ufydk ds lktks lkeku


(a) The rates cater for complete fluorescent tube light fittings
direct to walls or roof as ordered and connecting
electrically with the electrical system and all materials
required for the same. The rates also include cutting holes
in walls/roofs for wooden plugs/ gutties/rawl plugs and
making good the same to match with the existing surface.
The rate, however, does not include for supplying and
fixing of ceiling rose and copper flexible twisted twin
cord and also for the chain and hooks or conduits and the
like.
(b) Where fluorescent tube light fittings are fixed stiff with
conduit; conduit and its accessories; and additional
conduit and cable beyond 1.5m length shall be measured
separately under items 3327 and 3330-A (Fixing included).
EACH

d bu njksa esa ltkoVh izdk'k ufydk ds lai.w kZ la;kst


a dksa dks
fufnZ"Vkuqlkj nhokjksa ;k Nr esa lh/ks dscy yxkus rFkk fo|qr
iz.kkyh ls bldk la;kstu djus rFkk blds fy, lHkh lkexzh dk
izcU/k djus dk izko/kku gSA bu njksa esa nhokjks@
a Nrksa es]a ydM+h
dh MkVs@
a xqfO;ka@dPph MkVsa yxkus ds fy, Nsn dkVuk o ml
LFkku dks fo|eku lrg ls feykrs gq, Bhd djuk Hkh 'kkfey gSA
rks Hkh bu njksa es]a Nr ds dVksjh o rkacs dh yphyh ejksMh+ gqbZ
nqgjh Mksjh rFkk tathj] dkaVs Nyys ;k ufy;kn o ,slh gh
oLrqvksa dh vkiwfrZ djuk rFkk yxkuk 'kkfey ugha gSA
[k tgka ltkoVh izdk'k ufydk ds la;kstd likV uyh ds lFk
yxh gS] ogka uyh o bldh lgk;d lkexzh rFkk vfrfjDr uyh
vkSj 1-5 eh- yEch rkj dks en 3327 o 3330, ds varxZr izFkd
ls ekik tk;sxk LFkkiu lfgr!

Rs.
S&F

Rs.
Fixing
only

426

51.60

19356 Fluorescent tube light fitting. ,1x28


w,230v Energy efficient T5, Box type,
epoxy powder coated CRCA sheet
housing with reflector cover channel,
with electronic ballasts, bipin holders,
connector block, etc. complete with all
accessories internally pre-wired and
including connecting up with twin
core twisted flexible copper conductor

cable with suitable size.

893

51.60

19357 Fluorescent tube light fitting. ,1x28


w,T5 EEF 230v .industrial batten type,
powder coated top cover, with
electronic ballasts, bipin holders,
connector block, etc. complete with all
accessories internally pre-wired and
including connecting up with twin
core twisted flexible copper conductor

cable with suitable size.

986

51.60

19355 Fluorescent tube light fitting.


decorative strip type (patty type)1x28
wT5, 230v, , with electronic ballasts,
bipin holder, connector block, etc.
complete with all accessories
internally pre-wired and including
connecting up with twin core twisted
flexible copper conductor cable with

suitable size.

410

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
FLUORESCENT TUBLE LIGHT FITTINGS/CFL FITTINGS/ FLAME PROOF FITTING

ltkoVh izdk'k ufydk ds lktks lkeku


EACH

S&F

Fixing
only

Rs.

Rs.

1413

59.50

19359 Fluorescent tube light fitting. Single


tube,1x28 w, 230v Energy efficient
T5,Surface mounted DECORATIVE
MIRROR OPTIC TYPE, with electronic
ballasts, bipin holders, connector
block, etc. complete with all
accessories internally pre-wired and
including connecting up with twin
core twisted flexible copper conductor

cable with suitable size.

2853

51.60

19360 Ditto, but Single tube,2x28 w ,230v

ditto.

3325

59.50

2332

85.90

398

51.60

19358 Fluorescent tube light fitting, 2x28


w,T5 EEF 230v .industrial batten type,
powder coated top cover, with
electronic ballasts, bipin holders,
connector block, etc. complete with all
accessories internally pre-wired and
including connecting up with twin
core twisted flexible copper conductor

cable with suitable size.

19361 Ditto, but Single tube,2x28 w , 230v


Energy efficient T5, Recessed

mounting ditto.
19362 Fluorescent tube light fitting.
Decorative strip type (patty type)1x36
w, 230v, with electronic ballasts,
bipin holder, connector block, etc.
complete with all accessories
internally pre-wired and including
connecting up with twin core twisted
flexible copper conductor cable with
suitable size.

411

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
FLUORESCENT TUBLE LIGHT FITTINGS/CFL FITTINGS/ FLAME PROOF FITTING

ltkoVh izdk'k ufydk ds lktks lkeku

EACH

19363 Fluorescent tube light fitting, 1x36


w,230v , Box type, epoxy powder
coated CRCA sheet housing with
reflector cover channel, with electronic
ballasts, bipin holders, connector
block, etc. complete with all
accessories internally pre-wired and
including connecting up with twin
core twisted flexible copper conductor

cable with suitable size.


19364 Ditto, but Fluorescent tube light fitting,

2x36 w,230v , Box type, ditto.


19365 Fluorescent tube light fitting, 1x36 w,
230v .industrial batten type, powder
coated top cover, with electronic
ballasts, bipin holders, connector
block, etc. complete with all
accessories internally pre-wired and
including connecting up with twin
core twisted flexible copper conductor

cable with suitable size.


19366 Ditto, but Fluorescent tube light fitting,
2x36 w, 230v .industrial batten type,

ditto.

S&F

Fixing
only

Rs.

Rs.

725

51.60

1110

59.50

893

51.60

1282

59.50

1640

51.60

2300

59.50

19367 Fluorescent tube light fitting. Single


tube, 1x36 w, 230v,Surface mounted
DECORATIVE MIRROR OPTIC TYPE
, with electronic ballasts, bipin holders,
connector block, etc. complete with all
accessories internally pre-wired and
including connecting up with twin
core twisted flexible copper conductor

cable with suitable size.


19368 Ditto, but Single tube, 2x36W, 230V,

ditto.

412

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
FLUORESCENT TUBLE LIGHT FITTINGS/CFL FITTINGS/ FLAME PROOF FITTING

ltkoVh izdk'k ufydk ds lktks lkeku

S&F

Fixing
only

Rs.

Rs.

19369 Fluorescent tube light fitting. Single


tube, 1x36 w, 230v, Recessed mounting
DECORATIVE MIRROR OPTIC TYPE,
with electronic ballasts, bipin holders,
connector block, etc. complete with all
accessories internally pre-wired and
including connecting up with twin
core twisted flexible copper conductor

cable with suitable size.

1966

72.70

19370 Ditto, but Single tube, 2x36 w, 230v

Recessed mounting ditto.

2650

85.90

393

49.60

260

49.60

531

49.60

EACH

19371 CFL light fitting, 1x9 w bulk head


luminaries, with lamp holders, etc.
complete with all accessories and
including connecting up with twin
core twisted flexible copper
conductor cable with suitable size of

230V, 50 HZ
19372 CFL light fitting, 1x11 w, 230v
attractive wall mounted any type,
without shade, with ballasts, lamp
holders, connector block, etc. complete
with all accessories pre-wired and
including connecting up with twin
core twisted flexible copper conductor

cable with suitable size.


19373 CFL light fitting, 1x11 w attractive
wall/ceiling mounted type with
metallic channel and white reflector,
suitable for mirror fittings with
ballasts, lamp holders, connector
block, etc. complete with all
accessories pre-wired and including
connecting up with twin core twisted
flexible copper conductor cable with

suitable size.

413

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
FLUORESCENT TUBLE LIGHT FITTINGS/CFL FITTINGS/ FLAME PROOF FITTING

ltkoVh izdk'k ufydk ds lktks lkeku


EACH

S&F

Fixing
only

Rs.

Rs.

19374 CFL light fitting, 2x11 w, 230V Ceiling


surface mounted mirror optics
decorative type, with ballasts; lamp
holders, connector block, etc. complete
with all accessories internally prewired and including connecting up
with twin core twisted flexible copper
conductor cable with suitable size.

1437

49.60

19375 CFL light fitting, 1x11/15/18 w, 230v


decorative wall mounting type with
multicolour ABS housing with poly
carbonate rings, and glass shade with
lamp holders, connector block, etc.
complete with all accessories prewired and including connecting up
with twin core twisted flexible copper
conductor cable with suitable size.

243

49.60

787

66.80

1933

66.80

19376 CFL light fitting, 1x18 w ,230v Indoor


recess mounting down light circular
type with reflector and detachable
ballast tray, with lamp holders,
ballast, connector block, etc. complete
with all accessories pre-wired and
including connecting up with twin
core twisted flexible copper conductor

cable with suitable size.


19377 CFL/FPL light fitting, 2x18 w, 230v
recessed
mounting
mirror
opticluminare with P5 paralite louvers
with lamp holders, ballast, connector
block, etc. complete with all
accessories pre-wired and including
connecting up with twin core twisted
flexible copper conductor cable with

suitable size.

414

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
FLUORESCENT TUBLE LIGHT FITTINGS/CFL FITTINGS/ FLAME PROOF FITTING

ltkoVh izdk'k ufydk ds lktks lkeku


EACH

19377 CFL light fitting, 1x25 w decorative


ceiling mounting circular type with
metallic channel and white reflector,
with lamp holders, connector block,
etc. complete with all accessories prewired and including connecting up
with twin core twisted flexible copper
conductor cable with suitable size.
19378 FPL light fitting, 3x36 w, 230v recessed
mounting mirror optic Iuminare with
P5 paralite louvers complete for POP
ceiling, with lamp holders, ballast,
connector block, etc. complete with all
accessories pre-wired and including
connecting up with twin core twisted
flexible copper conductor cable with

suitable size.
19378 BULK HEAD CFL light fitting.
flameproof type FLP-WP of 1x 26 w
built in control gear box made of
aluminium alloy LM6 , with all
accessories, ballast, lamp holders, etc.

internally prewired

S&F

Fixing
only

Rs.

Rs.

904

49.60

4020

76.00

6665

72.70

19379 Fluorescent tube light fitting.


flameproof type FLP-WP of T5 1x28 w
including integral reflector made of
alluminium alloy LM6 , with
electronic ballast, bipin holders,
.connector block, etc., and all
accessories pre-wired and including
connecting up with twin core twisted
flexible copper conductor with suitable

size.

8626

72.70

19380 Fluorescent tube light fitting.


flameproof type FLP-WP of T5 2x28W
including integral reflector made of
alluminium alloy LM6 , with
electronic ballast, bipin holders,
connector block, etc., and all
accessories pre-wired and including
connecting up with twin core twisted
flexible copper conductor with suitable

size.

16946

82.70

415

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
FLUORESCENT TUBLE LIGHT FITTINGS/CFL FITTINGS/ FLAME PROOF FITTING

ltkoVh izdk'k ufydk ds lktks lkeku


EACH

19381 Fluorescent tube light fitting. 1 x36W


flameproof type FLP-WP made of
aluminium alloy LM6, with electronic
ballast, bipin holders, connector block,
etc. complete with all accessories
prewired and including connecting up
with twin core twisted flexible copper
conductor cable with suitable size.

S&F

Fixing
only

Rs.

Rs.

19382 Ditto, but 2x36W flameproof type FLPWP made of aluminium alloy LM6,

ditto.

7517

72.70

14274

82.70

19383 Supply &Fixing BULK HEAD, metal


halide light fitting 2x36 W flameproof
type FLP - WP of 1x70 W built in
control gear box made of alluminum
alloy LM6 with all accessories, ballast,
lamp holders, etc and internally pre

wired.

7557

72.70

LIGHT FITTINGS
LAMP HOLDERS

M&L

EACH

lkexzh ,oa
Je

19384 Lamp holder, PVC/Polycarbonate


type with cord grip cap suitable for

pendant fittings
19385 Lamp holder, PVC/Polycarbonate
type with back plate suitable for

batten fittings

Fixing Fixing in
only
repairs

Rs.

Rs.

40.00

18.50

ejEer esa
fLFkj.k 19384 ySai gksYMj] ih oh lh@iksfydkcksZusV dh
Rs.
dk;k Mksjh dlh Vksih okys] yVdus okys
20.40
miLdjksa ds fy, mi;qDr

18.50

19385 ySai gksYMj] ih oh lh@iksfydkcksZusV dh


dk;k] iz"B IysV okys dk.B iVjh ds fy,
mi;qDr

40.00

dsoy
fLFkj.k

ySai gksYMj
iz R ;s d

20.40

416

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
LIGHT FITTINGS-Contd...

izdk'k la;kstd lkexzh tkjh


Table Contd...
EACH

S&F

Fixing
only

Fixing
only in
repairs

SHADES
Rs.

Rs.

Rs.

19386 Switch piano, flush type single

pole, one way 5 Amp

34.30

15.50

17.00

19387 Ditto, but 15 Amp

86.50

21.10

23.30

19388 Ditto, but 15 Amp 2 way

39.00

15.90

17.40

19389 Modular switch 1 way 6A, 1

module

130.10

15.80

17.40

19390 Modular switch 1 way 10A, 1

module

166.80

15.80

17.40

19391 Modular switch 1 way 16A, 1

module

194.90

18.00

19.80

19392 Modular switch 2 way 6A, 1

module

147.40

15.80

17.40

19393 Modular switch 2 way 10A 1

module

190.50

15.80

17.40

19394 Bell push, flush type, 5 amp

39.00

15.90

17.40

19395 Modular Bell push 6A 1 module

162.50

15.80

17.40

iz R ;s d
N=
19386 fctyh cVu] I;kuks likV fdLe] ,d /kqoz h]
,d rjQk] 5 ,Ei
19387 mi;qZDr] fdUrq 15 ,Ei

MODULAR SWITHES

19394 ?kaVh iq'k] likV vkdkj 5 ,Ei /kkfjr


ctj vkSj ?kafV;ksa

BUZZERS AND BELLS


19396 Buzzer, Ding Dong AC. 230 volts,

single pole

82.30

26.40

29.10

19397 Bell, AC, 230 volts, single pole

126.50

26.40

29.10

19398 Bell Multi Music type

279.70

26.40

29.10

19399 Socket, 6A - 2/3 pin combined 2

module,

203.60

18.00

19.80

19400 Socket 6A/16A - 2/3 pin combined

2 module,

279.10

18.00

19.80

637.10

15.80

17.40

MODULAR SOCKETS

MODULAR FAN REGULATOR


19401 Fan step regulator, 120W - 2 module

19396 ctj] , lh 230 oksYV ,d /kzqoh

19397 ?kaVh , lh 230 oksYV ,d /kqzoh

417

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19& fo|qr dk;Z
LIGHT FITTINGS-Contd...

izdk'k la;kstd lkexzh tkjh


Table Contd...
MODULAR WHITE COVER
PLATE WITH FRAME

Rs.

Rs.

Rs.

19402 White cover plate with frame,

1 module

99.80

13.50

14.90

19403 -Ditto- but 2 module

106.30

13.50

14.90

19404 -Ditto- but 3 module

112.80

13.50

14.90

19405 -Ditto- but 4 module

121.00

15.30

16.90

19406 -Ditto- but 6 module

207.30

15.30

16.90

19407 -Ditto- but 8 module

226.80

15.30

16.90

19408 Metal flush box 1/2 module

76.60

24.80

27.30

19409 -Ditto- but 3 module

76.60

24.80

27.30

19410 -Ditto- but 4 module

96.00

24.80

27.30

19411 -Ditto- but 5 module

141.40

27.10

29.80

19412 -Ditto- but 6 module

156.50

27.10

29.80

19413 Socket outlet 3 pin, 15 Amp, flush

type

91.70

26.40

29.10

19414 Socket outlet 2 in 1, 3 pin, 5 and 15

amp flush type

95.20

26.40

29.10

19415 Socket outlet 2 in 1, 3 pin, 5A

51.50

23.80

26.20

19416 Socket outlet 3 pin, 5A, flush type

50.30

23.80

26.70

MODULAR METAL
FLUSH BOX

SOCKET OUTLETS AND


SWITCH SOCKET OUTLETS

418

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19& fo|qr dk;Z
SWITCHES
fctyh ds cVu tkjh
M&L
EACH

Fixing
only

Fixing in
repairs

lkexzh ,oa
Je

dsoy
LFkkiu

ejEer esa
LFkkiu

19417 Switch socket combination 2


in 1, 3 pin, 5 and 15 Amp

flush type universal

Rs.
99.60

Rs.
40.80

Rs.
47.60

19418 -Ditto- but 3 pin 5A

95.20

39.70

43.60

19419 Switch socket combination 2

in 1, 5 A flush type

109.30

39.70

43.60

19420 Switch socket combination 3

pin 16A, flush type

151.10

47.60

52.30

19421 -Ditto- but 5A/16A, 5 in 1

159.30

47.60

52.30

19422 -Ditto- but 5A/16A, 5 in 1


flush type with fuse & neon

incator

199.30

47.60

52.30

19423 Switch socket Combination

16A, 6 pin, 3 module

674.10

22.60

24.80

19424 Switch socket outlet 3 pin 5

amp' flush type

65.60

32.30

34.00

19425 Switch socket outlet 3 pin, 15

amp, flush type

97.20

40.80

42.50

19426 Switch socket outlet multipurpose 3 pin, 15 amp and


one pin, 5 amp controlled by

one switch

99.60

40.80

42.50

iz R ;s d
19417
19417cVu dksVj la;kstu ,d esa nks] 3
fiu 5 vkSj 15 ,Ei] likV vkdkj
lkekU;

MODULAR SWITCH
SOCKET COMBINATION

19427

19424 cVu dksVj fuxZe] 3 fiu] 5 ,Ei]

likV vkdkj
19425
19425cVu dksVj fuxZe] 3 fiu] 15 ,Ei]
likV vkdkj
19426
19426cVu dksVj fuxZe] vusd iz;kstuh;]
3 fiu] 15 ,Ei vkSj 1 fiu 5 ,Ei]
,d cVu ls fu;af=r

19427

FLAME PROOF SWITCHES & SWITCH SOCKET COMBINATIONs


iz R ;s d

EACH
S&F

Fixing Fixing only


only
in repair
Rs.
Rs.

19428Switch flame proof rotary


type with termination box in
LM6, 16A, single pole 250V

2003.40

39.70

43.63

19429-Ditto- but double pole

2083.40

39.70

43.63

19430-Ditto- but 25A, double pole

2237.20

39.70

43.63

19431Flame proof switch socket &


plug combined in LM6 cable
termination box in LM6, 16A,

250V, 2P+earth

5390.90

66.10

72.70

19432-Ditto- but 25A

5998.40

66.10

72.70

Rs.

419

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19& fo|qr dk;Z
MINIATURE CIRCUIT BREAKER (M.C.C.Bs.)
lw{eh; eaMyh; vojks/kd ,e lh lh ch,l

EACH

MCCBs 415V, 16 KA, 4 Pole


16A

19433 MCCBs 415V,


16KA, 4 Pole

25A

40A

5329.60 5210.40

63A

100A

125A

4924.50 4872.50 4693.90 5029.40

Labour

Labour

only

only

upto

100A

63A

& 125A

52.20

59.90

RCCBs FOR EARTH LEAKAGE PROTECTION


EACH

25A

40A

63A

Fixing only
upto 63A

19434

Double pole, 30mA

1867.10

2188.30

2563.90

23.50

19435

Double pole, 100mA

1940.50

2276.00

2664.00

23.50

19436

Double pole, 300mA

1958.60

2296.00

2688.80

23.50

19437

Four pole, 30mA

2485.90

2519.30

2905.30

29.40

19438

Four pole, 100mA

2584.10

2614.60

3022.60

29.40

19438A Four pole, 300mA

2608.90

2639.40

3051.20

29.40

RCBOs FOR EARTH LEAKAGE, OVERLOAD & SHORT- CIRCUIT PROTECTION


6A

10A

16A

25A

32A

40A

63A

Fixing
only up
to 63A

2160.70 2140.70

2110.20 2110.20 2322.80 2695.50

3138.70

23.50

Double pole, 100mA

2626.80 2602.10

2564.90 2564.90 2564.90 2874.70

3346.50

23.50

19441

Double pole, 300mA

2589.70 2589.70 2589.70 2901.40

3346.50

23.50

19442

Four pole, 30mA

2853.70 2963.30 2963.30 3008.10

3573.40

23.50

19443

Four pole, 100mA

3188.30 3128.30 3128.30 3193.10

3669.70

23.50

19444

Four pole, 300mA

3250.30 3158.80 3158.80 3223.60

3704.10

23.50

19439

Double pole, 30mA

19440

ISOLATORS

Supplied & fixed


240V

19445
19446
19447
19448
19449
19450

Isolator SP
Isolator SPN
Isolator DP
Isolator TP
Isolator TPN
Isolator Four

pole

415V

32A

40A

63A

100A

32A

40A

63A

80A

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

100A
Rs.

140.50

152.50

152.50

228.80

288.70

368.20

288.70

368.60

307.40

331.30

435.20

389.90

429.90

529.70

507.30

555.90

642.70

666.50

529.80

786.10

581.20

720.30

830

489.80

509.80

569.70

509.80

569.70

420

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19& fo|qr dk;Z
SHEET METAL ENCLOSURES WITH SOCKET PLUG TOP AND MCBs
uan 'kh"kZ dksVj vkSj ,e lh ch ds lkFk /kkrq pknj ds ?ksjs
iz R ;s d

EACH
19451 Single pole and
neutral enclosure with
a two pin and earth
plug and socket
complete with one
single pole MCB

19452 Single pole

19453 Double pole


19454 Triple pole and earth
encolsure with a three
pin and earth plug with
socket complete with
one triple pole MCB

vkiwfRRZk o fLFkj.k

Supplied & fixed


240 V

415 V

10amp

20amp

20amp

32amp

Rs.

Rs.

Rs.

Rs.

866.20

828.10

1129.00

2726

1004.40 1692.70

19451

,dy iksy ,oa rVLFk


?ksjk] lkFk esa ,d nks
63amp
fiu o Hkw;kstu MkV o
Rs.
dksVj o ,d ,dy iksy
,e lh Ckh ds lkFk lai.w kZ
19452 ,dy iksy
19453 f} iksy
19454 f= iksyh o Hkw;kstu ?ksjk lkFk
esa rhu fiu o Hkwfe MkV o
dksVj rFkk ,d f= iksyh
6897.40
,e lh Ckh lfgr lai.w kZ

SHEET METAL ENCLOSURES FOR DB'S WHEN MCBs TO BE USED


Mh ch ds fy, /kkrq dh pknj ds ?ksjs tc ,e lh ch dk iz;ksx djuk gks
EACH

Single Door

Double Door

Supplied & fixed

Supplied & fixed

240 V

415 V

240V

415V

Rs.

Rs.

Rs.

Rs.

204.50

233.10

4 way with 200 amps rated bus

bar

630.40

1053.60

8 way Ditto

777.20

1232.90

12 way Ditto

922.40

1493.40

1139.90

1838.60

1648.60

2564.90

2035.80

3147.30

2414.40

3735.60

19455 Single pole & neutral


1 way without bus bar

2 way Ditto

16 way Ditto
19456 Triple pole and neutral

4 way Ditto
6 way Ditto

8 way Ditto

12 way Ditto

3572.00

5669.10

16 way Ditto

4283.40

6797.20

iz R ;s d

19455

,dy iksy rFkk rVLFk


1 ekxhZ fcuk cl ckj
2 ekxhZ fcuk cl ckj
4 ekxhZ 200 ,Ei fu/kkZj cl ckj

lfgr
8 ekxhZ mi;qZDr
12 ekxhZ mi;qZDr
16 ekxhZ mi;qZDr
19456 f= iksyh rFkk rVLFk
4 ekxhZ mi;qZDr
6 ekxhZ mi;qZDr
8 ekxhZ mi;qZDr
12 ekxhZ mi;qZDr
16 ekxhZ mi;qZDr

421

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19& fo|qr dk;Z
LIGHTING CONDUCTORS
fctyh ds lapkyd

fctyh ds lapkydksa dh njksa esa [kqnkbZ rFkk feh dk;Z 'kkfey ugha
gSA
M&L
Fixing only Fixing in repairs
iz R ;s d
lk- o Je dsoy LFkkiu ejEEr esa LFkkiu 19457 ok;q fuxZe] ,dy uksd vY;qfefu;e
Rs.
Rs.
Rs.
dh 12 feeh O;kl o 300 feeh
136.80
41.00
45.10

yEch NM+
19458 ok;q fuxZe] ,dy uksd rkacs dh 12
243.80
46.30
50.90
feeh O;kl o 300 feeh yEch NM+

19459 ijh{k.k fcUnq lhekar lewg fef+Jr


/kkrq ;k QklQksjl rkacs ls cuk
rFkk 757525 feeh uki ftlesa
ojesa ls Nsn djds 3 feeh O;kl 25
feeh yEcs 3 'kh"kZ isp yxs gksa lfgr
582.60
35.70
39.30

The rates for lightning conductors do not include for excavation


and earthwork.
EACH
19457 Air termination, single
pointed aluminium rod 12mm
dia and 300mm long
19458 Air termination, single
pointed, copper rod 12mm dia

and 300mm long


19459 Test point terminal block made
of gun metal or phosphorus
bronze size 75x75x25mm
drilled and screwed including
3 nos. 8mm dia 25mm long
hex. head screw

iz f r ehVj

PER RUNNING METRE


19460 Aluminium strip 25 x 3.15mm
with saddles and fixing
screws etc. for roof conductors
and down conductors above

ground
19461 Copper strip 20 x 3.15mm with
saddles and fixing screws etc.
for roof conductors and down
conductors above ground
19462 Copper strip 32 x 6mm buried
in ground

19463 Galvanised iron strip 32 x


6mm buried in ground

55.00

7.90

8.70

298.50

9.30

10.20

896.60

12.90

14.20

132.10

12.90

14.20

19460 Nr ds ij rFkk uhps tehu ls ij ds


lapkydkas ds fy, 253-15 feeh dh
vY;qfefu;e dh ikh dh dkBh

ispksa vkfn ls dlh gqbZ


19461 Nr ds mij rFkk uhps tehu ls
mij ds lapkydksa ds fy, 203-15
feeh dh rkacs dh ikh dh dkBh]
ispksa vkfn ls dlh gqbZ
19462 rkacs dh 326 feeh dh ikh tehu
esa nch gqbZ
19463 tLrh yksgs dh 326 feeh dh
ikh tehu esa nch gqbZ

422

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19& fo|qr dk;Z
PVC / POLYCARBONATE

ih oh lh@iksfydkcksZusV
PVC RECTANGULAR BLOCK
EACH
19464 PVC rectangular block for
mounting, switches, sockets,
fan regulator etc. with 3 mm
thick plastic laminated sheet
cover of size 100 mm x 100 mm

and 50 mm deep
19465 Ditto,
deep
19466 Ditto,
deep
19467 Ditto,
deep
19468 Ditto,
deep

but 175 x 100 x 50 mm

but 200 x 150 x 50 mm

but 250 x 200 x 50 mm

but 350 x 300 x 50 mm

M&L
Rs.

Rs.

Fixed in
repairs
Rs.

44.90

9.30

10.20

58.90

11.90

13.10

83.30

16.50

18.20

125.20

21.16

23.30

211.00

26.10

28.60

Fixing only

MISCELLANEOUS

fefJr lkexz h
EACH

19469 Ceiling rose, 3 phase/PVC/


polycarbonate, isolated body

19470 Boxes junctions, plastic, round,

four terminals

M&L Fixing only Fixed in


lkexzh ,oa dsoy LFkkiu
repairs
Je
ejEer esa LFkkiu
Rs.
Rs.
Rs.

22.80

7.90

8.70

iz R ;s d

19469 lhfyax dVksjh] 3 Qst] ih oh


Z Vs ] vkblksyfs VM cksMh
lh@iksfydkcksu
19470 IykfLVd ds xksy pkj fljs okys
cDls

EARTHING

HkwlaidZu tkjh
1. The rates for earthing under items 19471 to 19473 7.
includes the cost of:
(a) Earth electrode.
(b) Main earthing lead from earth electrode to test point
upto 7.5 metre.
(c) Material and labour for connecting earth electrode
and earthing lead as specified.
(d) Adequate quantity of charcoal dust and common salt.
(e) All labour involved including testing of earth net work.
2.

The rates however do not include the following which shall


be measured and paid separately under appropriate items/
sections.

1- en 19471 ls 19473 dh njksa es fuEu dk ewY; 'kkfey gS%


d Hkwfe bySDVksMA
[k Hkwfe laidZu ls fujh{k.k fcUnq rd 7-5 eh esu Hkwlia dZu rkj
x funs'kkuqlkj HkwlaidZu o laidZu rkj dks tksM+us esa iz;qDr
lkexzh o JeA
?k i;kZIr ek=k esa dks;ys dh jk[k rFkk lkekU; uedA
p lHkh izdkj dk] Hkw;kstu O;oLFkk dh tkap dk;Z ls lacfa /kr
JeA
2- fQj Hkh] bu njksa esa fuEu 'kkfey ugha gS ftUgsa lacfU/kr [kaMks@
a njksa
ds vUrxZr izFkd ekik tk;sxk] rFkk Hkqxrku gksxkA

423

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19& fo|qr dk;Z
EARTHINGContd...
HkwlaidZu tkjh

d [kqnkbZ o feh dk;Z ;k bySDVksM ds fy, ojes ls Nsn


djukA
(b) P.C.C. pit and C.I. cover.
[k izofyr lhesVa dahV dk xM~<k vkSj yksgs ds <ys vkoj.kA
x tyuyh lfgr dhi] rkj tkyh rFkk rkacs ds iky vkfn
(c) Funnel with watering pipe, wire mesh and copper lugs
etc. as specified.
tSlk fd funsZ'k gksA
(d) G.I. protection pipe of size ordered specified for
?k Hkw;kstu rkj dh ;kaf=dh gkfu ;k ik;u ls Hkw;kstu rkj
protection of earthing lead from mechanical injury
dh lqj{kk gsrq fufnZ"V@funs'Z kkuqlkj tLrh yksgs ds lqj{kk
or tempering.
uyA
(e) Test point and extra length of main earthing lead
M- tkap fcUnq vkSj 7-5 ehVj ls vf/kd yEckbZ ds eq[;
beyond 7.5 metres.
laidZu rkjA
(f) Connecting lead from test point to main switch or
p tkap fcUnq ls eq[; /kkjk cVu ;k cksMZ rd dh la;kstu
switch board or equipment to be earthed.
rkj ;k lkeku tks Hkwfexr djuk gSA
3. On testing after completion if the desired earth resistance 3- laifw k ds ckn ;fn ik;k tk;s fd visf{kr Hkwifz rjks/k izkIr ugha gqvk
is not obtained the earthing will be redone at no extra cost.
gS rks Hkwlia dZu fcuk vfrfjDr Hkqxrku ds nksckjk iwjk djuk gksxkA
(a) Excavation and earth work or drilling hole for
electrode.

EACH SET

M&L

Fixing only

lkexzh ,ao Je

dsoy LFkkiu

19471 Earthing complete with galvanised


steel earth plate electrode
60 60cm. 6mm thick, buried
directly in ground (earth pit not less
than 2.25 metres deep below ground
level) with top edge of the plate not
less'than 1.5 metres below normal
ground level, connected to
galvanised earth lead wire 4.0mm
dia by means of bolts, nuts, check
nuts and washers of galvanised iron
or steel all as shown in electrical
plate No. 5 connected to earthing test
point all as specified or indicated
including testing on completion

Rs.

Rs.

2536.80

347.20

19472 Ditto, but using galvanised iron


strip 254mm as earthing lead

2899.90

347.20

19473 Ditto, but using galvanised iron


strip 326mm as earthing lead

3277.50

347.20

izR;sd laxzg
19471 lai.w kZ Hkq;kstu dk;Z] ftlesa 60606 feeh
eksVh tLrh yksgs dh bySDVkM
s okyh IysV
lh/kh Hkwfe esa lekfgr Hkwfe ds xM~<s dh
xgjkbZ 2-25 eh ls de u gks IysV ds ijh
fdukjs dh xgjkbZ Hkwfe dh lkekU; lrg ls
1-5 eh ls de u gks] rFkk 4-0 feeh O;kl
dh tLrh Hkw;kstu rkj ls dkcys o f<ofj;ks]a
ij[k dkoys ;k tLrh yksgs ;k bLikr ds
oklZy ls tqM]s+ lc oSlk gh tSlk fctyh
dh 5 uEoj dh IysV esa n'kkZ;k x;k gS Hkwfe
ijh{k.k fcUnq ls tqMk gks( o lc mlh izdkj
tSlk fufnZ"V gks ;k funs'Z k gks rFkk lai.w kZ
gksus ij ijh{k.kA
19472 mi;qZDr] fdUrq 254 feeh dh tLrh
yksgs dh if;ksa dk Hkwlia dZu rkj ds :i
ls iz;ksx djrs gq,A
19473 mi;qZDr] fdUrq 326 feeh dh tLrh
yksgs dh if;ksa dk Hkwlia dZu rkj ds :i
esa iz;ksx djrs gq,A

424

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19& fo|qr dk;Z
EARTHINGContd...
HkwlaidZu tkjh
EACH SET

M&L

19474Dilto, but using copper plate


6060cm 3.15mm thick electrode
and 20 3mm copper strip as

earthing lead
19475Earthing complete with galvanised
steel pipe electrode, 40mm bore,
medium grade, 2.5 metres length,
buried directly and preferably
vertically in ground with top edge
not less than 1.25 metres below
ground level connected with
earthing lead of 4mm dia galvanised
iron or steel wire all as shown in
Plate No. 4 to the earthing test point
all as specified and indicated
including testing on completion

lkexzh ,ao Je
Rs.

7642.40

2121.50

Fixing only

izR;sd laxzg

dsoy LFkkiu 19474 mi;qZDr] fdUrq 60603-15 lseh eksVh


Rs.
rkacs dh bySDVksM IysV rFkk 203 feeh
rkacs dh if;ksa dk Hkwlia dZu rkj ds :i esa

iz;ksx djrs gq,


347.20
19475 lai.w kZ Hkw;kstu dk;Z] ftlesa 40 feeh Nsn ds
e/;e Js.kh] 2-5 eh- yEcs tLrh yksgs ds
bySDVkM
s fdukjksa ds uy tks Hkwfe esa lh/ks ;k
mfpr gksxk lekukUrj ,sls lekfgr fd;s
tk;sa ftlls mlds ijh Nksj dh xgjkbZ
Hkwfe dh lkekU; lrg ls 1-5 eh- ls de u
gks rFkk 4 feeh ds tLrh yksgs ;k bLikr ds
rkjksa ls tqM+sa gks lc mlh izdkj tSlk fd
fctyh dh ua- 5 IysV esa n'kkZ;k x;k gS ds
vuqlkj lw;ksftr tkap fcUnq ls tksMu+ k tSls
fd fufnZ"V gks rFkk funsZ'k gks rFkk laiw.kZ

gksus ij ijh{k.k vkfn


347.20

EACH

izR;sd laxzg

19476Ditto, but by using galvanised iron


25x4mm strip as earthing lead

19476 mi;qZDr] fdUrq 254 feeh dh tLrh yksgs


dh if;ksa dk Hkwlia dZu rkj ds ;i esa iz;ksx
djrs gq,
19477 mi;qZDr] fdUrq 326 feeh dh tLrh yksgs
dh if;ksa dk HkwlaidZu rkj ds :i easa
iz;ksx djrs gq,A

19477Ditto, but by using galvanised iron


326mm strip as eartlung lead

19478 Chemical earthing with copper earth


plate 90x60cmx5mm & copper earth
strip 50x6mm

19479Ditto, but copper earth strip 32x6mm

2484.50

347.20

2862.10

347.20

56042.00

393.50

49949.60

393.50

PER RUNNING METRE

iz f r ehVj

19480Earth continuity conductor or main


earthing lead fixed to wall on batten
or recess or chases or buried in
ground or drawn in conduit/pipe or
fixed to poles or any other indicated
situation for loop earthing etc. as
required 2mm dia galvanised iron or

steel wire

19480 Hkwferkj fujarjrk lapkyd ;k eq[; Hkwlia dZu


rkj] nhokj ;k cfYy;ksa ;k njkjksa ;k f>fj;ksa
ls yxh ;k Hkwfe esa nckuk ;k uyh@uydksa
esa ls ys tkbZ xbZ ;k Nsnksa ;k fdlh vU;
crkbZ xbZ fof/k Qans okyh HkwlaidiZu ds
fy, visf{kr 2 feeh O;kl ds tLrh yksgs
;k bLikr ds rkj }kjk
19481 mi;qDZ r] fdUrq 4 feeh O;kl ds tLrh yksgs
;k bLikr ds rkj

19481Ditto, but 4mm dia galvanised iron

or steel wire

15.30

11.60

18.30

14.00

425

SECTION 19

SECTION 19 ELECTRICAL WORK


[k.M 19& fo|qr dk;Z
EARTHINGContd...
HkwlaidZu tkjh
EACH SET
19482 Ditto, but 6mm dia galvanised iron

or steel wire
19483 Ditto, but 8mm dia galvanised iron

or steel wire
19484 Ditto, but 25x4mm galvanised iron

strip
19485 Ditto, but 32x6mm galvanised iron

strip
19486 Ditto, but copper strip

19487 Ditto, but 25x3mm aluminium

strip

M&L

Fixing only

lkexzh ,ao Je

dsoy LFkkiu

Rs.
22.10

Rs.
16.30

25.20

18.60

68.50

10.60

132.10

12.90

896.60

12.90

52.90

7.90

19488 Ditto, but 20x3mm copper strip

285.10

9.30

19489 Ditto, 4sq mm area aluminium wire

4.10

2.30

19490 Ditto, but 6 sq mm area aluminium

wire

5.00

2.30

19491 Ditto, but 7/1.60mm stranded

galva-nised steel wire

9.70

4.60

19492 2.00 mm dia GI wire

7.30

5.50

19493 4.00 mm dia GI wire

12.60

6.00

19494 8.00 mm dia GI wire

20.20

6.50

19495 8.00 mm dia GI wire

26.00

6.90

19496 Ditto, but 7/2.24mm Ditto

12.30

4.60

izR;sd laxzg
19482 mi;qZDr] fdUrq 6 feeh O;kl ds tLrh
yksgs ;k bLikr ds rkj
19483 mi;qZDr] fdUrq 8 feeh O;kl ds tLrh
yksgs ;k bLikr ds rkj
19484 mi;qZDr] fdUrq 254 feeh tLrh yksgs dh
ih
19485 mi;qZDr] fdUrq 326 feeh tLrh yksgs dh
ih
19486
19487 mi;qZDr] fdUrq 253 feeh tLrh yksgs dh
ih
19488 mi;qZDr] fdUrq 203 feeh rkacs dh ih]
19489 mi;qDZ r] fdUrq 4 oxZ feeh {ks= vY;qfefu;e
rkj
19490 mi;qDZ r] fdUrq 6 oxZ feeh {ks= vY;qfefu;e
rkj
19491 mi;qDZ r] fdUrq 7@1-60 feeh ekud tLrh
yksgs dh rkj
19492 2-00 feeh tLrh yksgs dh rkj
19493 4-00 feeh tLrh yksgs dh rkj
19494 6-00 feeh tLrh yksgs dh rkj
19495 8-00 feeh tLrh yksgs dh rkj
19496 mi;qDZ r] fdUrq 7@2-24 feeh ekud tLrh
yksgs dh rkj

ELECTRIC METERS (SUPPLIED BY M.D.)


fctyh ds ehVj vkiwfkZ ,e Mh }kjk
Rs.

iz R ;s d

19497 Fixing only and connecting electric meters

upto 25 amps

41.90

19498 Ditto, above 25 amps

69.80

19497 dsoy LFkkiu rFkk 25 ,Ei rd ds fctyh ds ehVj


dk la;kstu djuk
19498 mi;qZDr] fdUrq 25 ,Ei ls ij

EACH

426

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
FAN WORK
ia[ks dk dk;Z
The rates do not include for clamps, hooks, holdfasts etc. for
hanging fans.
EACH

19499 Hanging only ceiling fan (M.D.


supply) and connecting up
including provision of cable from

ceiling rose or connector to fan


19500 Fixing only exhaust fan (M.D.
supply) and connecting up
including provision of cable from
ceiling rose/connector to fan
19501 Fixing only fan regulator (M.D.

supply) and connecting

bu njksa esa ia[ks Vkaxus ds fy;s ifV~V;ka gqd idM ifV~V;ka vkfn
'kkfey ugha gSaA

Fixing or
Add if
hanging only fixed in
dsoy LFkkiu
tksMsa+ ;fn
;k yVdkuk
ejEer esa
LFkkfir
Rs.
Rs.
47.80

23.10

64.60

32.40

16.20

19.40

19502 Painting of ceiling fans complete, in situ


with synthetic enamel paint by spraying
including filling cavities with filler, one
coat after cleaning all dust etc. (M & L)
19503 Taking down fan, sealing cable end,
dismantling blades and removing fan and
blades to store

19504 Taking down regulator, sealing cable ends

and removing regulator to store

Rs.

67.10

50.90
11.60

iz R ;s d

19499 Nr ds ia[ks dks dsoy yVdkuk rFkk la;kstu


rFkk Nr ds dqM
a s ;k la;kstd ls ia[ks rd dh
rkj dh O;oLFkk lfgr
19500 ok;q fudkl ia[ks dk dscy LFkkiu ,eMh vkiwfkZ
rFkk mldk la;kstu] vkSj Nr ds dqMa @
s la;kstd
ls ia[ks rd dh rkj dh O;oLFkk lfgr
19501 ia[ks ds fu;ked <e Mh vkiwfkZ dk dsoy LFkkiu
o la;kstu
19502 Nr ds ia[ks ij lai.w kZr;k lhrw es]a iwoZ fufeZr
jaxhu jksxu ls ;a= }kjk fNM+ddj] Hkjkoh elkys
ls fjfDr;ksa dh HkjkbZ lfgr lQkbZ djus ds ckn
jax dk ,d vLrj djuk lkexzh ,oa Je
19503 ia[ks dks fudkyuk] rkj dks vyx djuk]
ia[kfM;ksa dks [kksyuk rFkk ia[ks o ia[kfM;ksa dks
HkaMkj ys tkuk
19504 fu;ked fudkyuk] rkj dks vyx djuk rFkk
fu;ked dks HkaMkj esa ys tkuk

FAN REGULATOR AND DIMMER


EACH

S&F

Fixing Fixing only


only
in repair
Rs.
Rs.

19505 S & F stepped type electronic fan


regulator flush type on the existing
phenolic laminated sheet etc. as reqd.

219.80

18.50

20.40

19506 S & F electronic dimmers, 450W, 250V


flush type on the exiting phenolic

laminated sheet etc. as reqd.

186.80

18.50

20.40

Rs.

WIRING
rkj O;oLFkk
1 rkj O;oLFkk dh njksa esa fuEu 'kkfey gSa%
(1) The rates for wiring include for:
(a) Supplying and fixing/drawing of cables
d rkjksa dh vkiwfkZ] la;kstu@QSykbZ] la;kstuksa lfgrA
including connections.
[k ydM+h dh cfYy;ksa] eksM+ksa fdukfj;ksa] Hkjko elkys] Vh
(b) Supplying and fixing wood battens, bends, cornvo;o vkfn ftudh cfYy;ksa] ij rkj fcNkus ds fy,
ers, fillers, tee-pieces etc. required for wiring on
vko';drk gksrh gS dh vkiwfkZ rFkk LFkkiuA
battens.
x lHkh lgk;d lkexzh tSls isp] ifr;ka] MkVsa] f'kdats vkfn
(c) Supplying and fixing all accessories such as
screws, clips, plugs, clamps etc. as specified for
dh vkiwfkZ djuk rFkk yxkuk] tSlk fd fufnZ"V gS] ftudh
securing cables, battens, conduits etc. to walls,
dscy] cfYy;ksa ufy;ksa vkfn dh nhokjksa] yksgs dh dfM+;ksa
steel joists etc.
ij yxkus ds fy, vko';drk gksrh gSA

427

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
WIRINGContd...
rkj O;oLFkk &tkjh--(d) Supplying and fixing of bushed conduit or
?k ?kuh ufy;ksa ;k phuh feh dh ufy;ksa ftuesa gksdj rkj
porcelain tubing for wiring to pass through walls,
nhokjksa Q'kksZa vkfn ls tkrh gS mudh vkiwfkZ rFkk LFkkiuA
floors, etc.
(e) Supplying and fixing of joint and junction boxes.
(f) Cutting holes in or through walls, taking up and refixing floor boards, notching or drilling holes through
joists and making good all disturbed work to match
the existing.
(g) Shellac varnishing as specified to wood battens, wood
blocks and other wood fittings and fixtures.
(h) Painting of battens and cables or surface conduits along
with painting of walls.
(i) Testing as specified.

M la;kstd rFkk laxe cDlksa dh vkiwfkZ rFkk LFkkiuA


p nhokjksa esa ;k vkjikj Nsn dkVuk] mBkuk rFkk Q'kksZa cksMZ dks
yxkuk ;k la;ktdksa esa nkars cukuk ;k cjes ls Nsn djuk rFkk
lHkh fo?kfBr dke dks fo|eku ls feykrs gq, Bhd djukA

N fufnZ"Vkuqlkj piM+k okjfu'k ydM+h dh cfYy;ks]a ydM+h ds


lkapksa rFkk ydM+h ds nwljs la;kstu o lktks lkeku ij iksrukA
t cfYy;ksa rFkk dscyksa ;k lkFk dh lrgh ufy;ksa ij nhokjksa
ds lkFk jksxu djukA
> fufnZ"Vkuqlkj ijh{k.kA
2 rkj O;oLFkk dh njksa esa fuEu 'kkfey ugha gSa%
(2) The rates for wiring do not include for:d ufy;ksa esa f>jh fudkyuk o cDlksa esa Mkyus ds fy, o
(a) Cutting chases for conduits and sinking's for boxes
nhokjksa Q'kksaZ vkfn dh ejEer djuk ml n'kk esa tgka rkjksa
and making good to walls, floors etc. in case of recessed
dks ufy;ksa }kjk nokuk gks ;k fudkyuk gksA
or concealed conduit wiring.
(b) Supplying and fixing terminal boxes for power plugs,
[k 'kfDr Iyx ds fy, lhekar cDls] ia[ks ds fu;kedks]a fctyh
fan regulators, switches, socket outlet etc., fixed flush
ds CkVuksa dksVj fudkvks vkfn dh vkiwfkZ rFkk LFkkiu
to the walls, as specified for surface wiring on wood
'kkfey ugha gS ftudks ydM+h dh cfYy;ksa ij lrgh rkjksa
battens.
dks nhokj esa ls yxk;k tkrk gSA
PER RUNNING
METRE

In Steel
conduit

Wiring for circuit/submain


wiring alongwith earth
wire with the following
sizes of FR PVC insulated
copper conductor, single S&F
core cable in surface/
recessed as required

In PVC
conduit

In PVC
casing
caping

In existing
surface/
recessed
steel/PVC
conduct

Labour
only

S&F

Labo- S&F
ur
only

Labo- S&F
ur
only

Labour
only

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

138.00 31.70

90.00

26.50

83.00

19.80

54.00

11.20

164.00 31.70

116.00 26.50

109.00 19.80

80.00

11.20

19509 2x4.0 sq. mm +


1x2.5 sq. mm
earth wire

205.00 31.70

157.00 26.50

149.00 19.80

121.00 11.20

19510 2x6.0 sq. mm +


1x4.0 sq. mm
earth wire

261.00 31.70

213.00 26.50

206.00 19.80

177.00 11.20

373.00 31.70

319.00 26.50

301.00 19.80

276.00 15.90

19507 2x1.5 sq. mm +


1x1.0 sq. mm
earth wire
19508 2x2.5 sq. mm +
1x1.5 sq. mm
earth wire

19511 2x10.0 sq. mm


+ 1x6.0 sq. mm
earth wire

Rs.

428

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
WIRINGContd...
rkj O;oLFkk &tkjh--In Steel
conduit

In PVC
conduit

PER RUNNING
METRE

19512 2x16.0 sq. mm


+ 1x10.0 sq.
mm earth wire

In PVC
casing
caping

In existing
surface/
recessed
steel/PVC
conduct

S&F

Labour
only

S&F

Labo- S&F
ur
only

Labo- S&F
ur
only

Labour
only

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

533.00 31.70 495.00

26.50

19.80

436.00 15.90

827.00 31.70 756.00

26.50

19.80

697.00 15.90

19514 4x2.5 sq. mm +


2x1.5 sq. mm
earth wire

249.00 31.70 197.00

26.50 183.00 19.80

150.00 11.20

19515 4x4.0 sq. mm +


2x2.5 sq. mm
earth wire

332.00 31.70 278.00

26.50 269.00 22.50

236.00 15.90

489.00 31.70 408.00

26.50 388.00 26.50

349.00 15.90

679.00 31.70 598.00

26.50 577.00 26.50

538.00 15.90

1075.00 36.40 937.00

31.10

31.10

861.00 18.50

1660.00 36.40 1492.00 31.10

31.10

1368.00 18.50

19513 2x25.0 sq. mm


+ 1x16.0 sq.
mm earth wire

19516 4x6.0 sq. mm +


2x4.0 sq. mm
earth wire
19517 4x10.0 sq. mm
+ 2x6.0 sq. mm
earth wire
19518 4x16.0 sq. mm
+ 2x10.0 sq.
mm earth wire

19519 4x25.0 sq. mm


+ 2x16.0 sq.
mm earth wire

429

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
RIGID NON-METALLIC PVC CONDUITS
dBksj /kkrq jfgr ih oh lh ufy;ka
PER
RUNNING
METRE

Supplied & fixed

Fixing only

vkiwfRRkZ ,ao LFkkiu

dsoy LFkkiu

19520Rigid non-metallic
PVC conduit exclusive
External dia
of boxes (junction/
terminal) but inclusive
Dia in mm
of all tees, bends,
elbows, reducers, bell
mouth tube ends and 20
25
32
fixing accessories
Rs.
Rs.
such as couplers, lock Rs.
nuts, saddles, pipe
35.00 46.00 66.00
hooks etc.

Ckkgjh O;kl
O;kl feeh esa
40

20&25 32&40

Rs.

Rs.

86.00 13.20

Rs.
17.90

iz f r ehVj

Fixed in
repairs

WEkjEer esa 19520 dBksj /kkrq ihohlh uyh fcuk


LFkkiu
cDls laxe@lhekar fdUrq
lHkh vU; la;kstuksa lfgr
tSls Vh;sa] eksM] dksfu;ka]
U;wudks]a ?kaVh eqga h uyh Nksj
rFkk LFkkiu lkexzh tsls
dekfu;k] rkys dkoys]
Rs.
dkfB;ka uy gqd vkfn
19.90

iz R ;s d

EACH
19521Junction boxes (1 to 4
21.00 23.70 37.00

way)

39.30 13.90

18.50

20.00

19521 laxe cDls 1 ls 4 ekxhZ

MOULDED CASE CIRCUIT BREAKER (MCCB)


EACH

M&L
Rs.

19522 MCCB 3 Pole .415 V. fixed type,


25 to 100 Amps with
breaking capacity 16 KA

3,710

19523 Ditto, but 125 Amps

3,930

19524 MCCB 3 Pole , 415 V, Adjustable type,


160 Amps with breaking

capacity 36 KA

7,600

19525 Ditto, but 200 Amps

8,900

19526 Ditto, but 250 Amps

13,900

19527 Ditto, but 350 Amps

17,000

19528 Ditto, but 400 Amps

18,700

19529 Ditto, but 500 Amps

20,900

19530 Ditto, but 630 Amps, 50 KA

24,500

430

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
MATERIALS (SUPPLIED ONLY)
lkexzh dsoy vkiwfRrZ
POLE/STRUTS

[ka H ks @ LrEHk

Rs.

EACH

iz R ;s d

19531 Steel tubular swaged poles complete


with cast iron base plate, finial taper
plug, bolts, nuts and screws as
specified type 410 SP-22 (8.5 metres

long)
19532 Ditto, type 410 SP-31 (9.00 metres

long)
19533 Ditto, type 410 SP-37 (9.50 metres

long)
19534 Ditto, type 410 SP-44 ( 10.00

metres long)
19535 Ditto, type 410 SP-55 (11.00 metres

long)
19536 Ditto, type 410 SP-64 (12.00

metres long)

19531 yksgs ds uyhnkj mUur [kaHks laiw.kZ ftuesa yxs


gksxs <ys yksgs ds vk/kkj IysV] pwMh+ nkj ikfMkV]
dkoys o f<ofj;k rFkk isp fufnZ"Bkuqlkj uewuk
410 ,l ih&22 8-5 eh- yEcs

PRESTRESSED CONCRETE POLES

7356.00
7669.00
7982.00
8472.00
11053.00
14190.00

Rs.

19532 mi;qZDr]

yEck
19533 mi;qZDr]

yEck
19534 mi;qZDr]

yEck
19535 mi;qZDr]

yEck
19536 mi;qZDr]

yEck

uewuk 410 ,l ih&31 9-00 ehuewuk 410 ,l ih&37 9-50 ehuewuk 410 ,l ih&44 10-00 ehuewuk 410 ,l ih&55 11-00 ehuewuk 410 ,l ih&64 12-00 eh-

iwoZ izfrcfyr dhaV ds [kaHks

EACH

iz R ;s d

19537 Prestressed concrete pole 11.0 metres


long, 152x152mm at top and
152x260mm at bottom, class 9
19538 Prestressed concrete pole 9.0 metres
long, 102x172mm at top and
102x279mm at bottom, class 10
19539 Prestressed concrege pole 9.0 metres
long, 102x152mm at top and
102x289mm at bottom, class 10
19540 Prestressed concrete pole 7.5 metres
long, 102x152mm at top and
102x281mm at bottom, class 11
19541 Prestressed concrete pole 7.5 metres
long, 102x102mm at top and
102x229mm at bottom, class 11

19537 iwoZ izfrcfyr dhaV [kaHks] 11-0 eh- yEcs]


'kh"kZ ij 152152 feeh rFkk ryh ij
260 feeh- oxZ&9
152

19538 iwoZ izfrcfyr dhaV [kaHks] 9-0 eh- yEcs]


'kh"kZ ij 102172 feeh rFkk ryh ij

102279 feeh- oxZ&10


19539 iwoZ izfrcfyr dhaV [kaHks] 9-0 eh- yEcs]
'kh"kZ ij 102152 feeh rFkk ryh ij
102289 feeh- oxZ&10

19540 iwoZ izfrcfyr dhaV [kaHks] 7-5 eh- yEcs]


'kh"kZ ij 102152 feeh rFkk ryh ij

102281 feeh- oxZ&11


19541 iwoZ izfrcfyr dhaV [kaHks] 7-5 eh- yEcs]
'kh"kZ ij 102102 feeh rFkk ryh ij

102229 feeh- oxZ&11

5223.00

3728.00

3500.00
2522.00

2381.00

431

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
MATERIALS (SUPPLIED ONLY)
lkexzh dsoy vkiwfRrZ
rku rkj

STAY WIRE
PER QUINTAL

19542 Galvanised stay


strand (Grade
2), size ....

7/4.0mm
7/4.0feeh

7/3.15 mm 7/2.50 mm 7/2.24 mm


7/3.15 feeh 7/2.50 feeh 7/2.24 feeh

Rs.

Rs.

Rs.

Rs.

5394.00

5394.00

5394.00

5394.00

iz f r fda o Vy
19542 tLrh yksgs ds yM+hnkj

rkj Js.kh 2 vkdkj---

la p kyd

Rs.
CONDUCTORS
19543 Aluminium
conductor steel
reinforced, all

sizes
19544 All aluminium
conductor, all

sizes
19545

19543 vYeksfu;e lapkyd


izofyr bLikr lHkh

vkdkj ds

18432.00

19544 iw.kZ vYeksfu;e lapkyd


lHkh vkdkj ds

17328.00

19545
rkj
iz f r ehVj

CABLES
Size of cable with aluminium
conductor in sq. mm

PER RUNNING METRE

vYeksfu;e lapkyd lfgr rkj dk vkdkj feeh esa


19546 Elastomer insulated

single core cable


19547 Elastomer sheathed

single core cable


19548 Elastomer sheathed flat

twin core cable


19549 PVC unsheathed single

core cable
19550 PVC single core cable

sheathed
19551 PVC flat twin core

cable
19552 Weather proof single

core cable
19553 Weather proof flat twin

core cable
19554 Cable with copper

conductor

1.5

2.5

10

16

Rs.

Rs.

Rs.

Rs.

Rs.

3.00

4.00

5.00

7.00

8.00

4.00

5.00

8.00

12.00 14.00

19546 jcM+ p<+s /kkjkjks/kd ,dy 'kk[kk


rkj
11.00 16.00
19547 jcM+ e<s+ likV ,dy /kkjk rkj

9.00

11.00 12.00

14.00 17.00

2.00

3.00

4.00

6.00

3.00

5.00

9.00

10.00 13.00

17.00 22.00

7.00

9.00

12.00

15.00 22.00

33.00 45.00

Rs.

25
Rs.

17.00 22.00

19548 jcM+ e<+s likV f}'kk[kk rkj


19549 ihohlh vue<+s ,dy 'kk[kk rkj

8.00

10.00 20.00

19550 ihohlh e<s+ ,dy 'kk[kk rkj


19551 ihohlh likV f}'kk[kk rkj

19552 rq rkieku lg ,dy 'kk[kk


rkj
19553 rq rkieku lg likV f}'kk[kk
8.00 10.00 14.00 18.00 23.00 30.00 44.00
rkj
15.40 26.10 40.30 60.50 96.10 155.50 251.50 19554 rkcak lpakyd lfgr rkj
4.00

6.00

8.00

10.00 12.00

16.00 23.00

432

SECTION 19

SECTION 19 ELECTRICAL WORK


[kaM 19&fo|qr dk;Z
MATERIALS (SUPPLIED ONLY)-Contd.
lkexzh dsoy vkiwfrZ tkjh
PER RUNNING METRE

External diameter of conduit in mm

iz f r ehVj

uyh dk ckgjh O;kl feeh esas


Stove enamelled, blank

/kkrq;qDr rIr dkyk


19555 Rigid steel conduit, welded

20

25

32

40

Rs.

Rs.

Rs.

Rs.

49.80

61.70

98.50

166.10

19555 dBksj yksgs dh uyh] Vkads


yxh
iz R ;s d

EACH
19556 Junction box, with cover

and outlets

14.20

23.70

33.20

19556 la x e cDlk] vkoj.k o


fudkl lfgr

iz R ;s d
19557
19557tLrh p<+h bLikr HkwlaidZu IysV] vkdkj 60606-3
1410.00
feeh
19558
19558mi;qDZ r] fdUrq rkacs dk ikj] vkdkj 60603-15 feeh
Rs.

EACH
19557 Galvanised, steel earth plate, size of

60cmx60cmx6.30mm
19558 Ditto, but copper plate, size 60cmx60cmx3.15

mm
19559 Galvanised, steel rod 16mm diameter and 2.5

metres length
19560 Copper rod 12.5mm diameter and 2.5 metres

length
PER QUINTAL
19561 Common salt commercial
19562 Charcoal dust/Breeze
19563 Mild steel wires, galvanised

29.70

4648.90

19559+ tLRkh bLikr NM+ 16 feeh O;kl rFkk 2-5 ehVj yEckbZ
134.87

19560
19560rkacs dh NM+ 12-5 feeh O;kl rFkk 2-5 ehVj yEckbZ
482.90

352.50
705.00
5933.70

19561
19562
19563

iz f r fda o Vy
vke ued&O;olkf;d
dPps dks;ys dh jk[k@dsjh
uje bLIkkr rkj@tLr p<+sa

433

SECTION 20A

SECTION 20AROAD WORK


[k.M 20,&lM+d dk;Z
SPECIAL CONDITIONS
foksk krsZ
20. A. 1
20A.1.1

Measurements
Measurements shall be taken of the net finished
work, except where otherwise stated.
20.A.1.2 Measurements of materials like stones,
aggregates, screenings, sand, etc. shall be taken
in bottomless boxes or measuring boxes or in
closely packed stacks on level ground. While
no special compaction is necessary by rammings/hacking or hammering, no attempt at
loose stacking will be permitted.
20.A. 1.3 Measurements for finished work for which
Materials and Labour rates are to be paid, shall
be taken in two stages, viz. measurements of
road aggregates etc., in stacks as stated in
20A.1.2 above, and measurements of the
completed work. The former is necessary to
ensure that the required quantities of road
aggregates have actually been collected and are
of the sizes, etc., indicated. Stack measurements
shall not, however, absolve the contractor from
the responsibility of conforming to the required
specification and dimensions, etc., and
provision of more materials, if necessary, to
make up the thickness, etc., indicated without
any extra charge to Government.
20.A.2
Rates
20.A2.1 Consolidation by hand rammingHand
ramming carried out in angles, edges, etc. where
a roller cannot be worked, is included in the
rates.

20,-1 eki
20,-1-1 iwfjr dk;Z dh eki fo'kq} yh tk;sxh] tc rd fd
dgha vU;Fkk u dgk x;k gksA
20,-1-2 lkexzh tSls iRFkj] feykos] Nkul] ckyw vkfn dh eki]
ryh jfgr cDlksa ;k ekih cDlksa ;k lery Hkwfe ij
lVkdj yxk;s x;s pV~Vksa ls yh tk;sxhA gkaykfd fo'ks"k
?kuRo cukus ds fy,] njslh djus@dwVus ;k gFkkSMk+ pykus
dh vko';drk ugha gS] fQj Hkh <hys pV~Vs yxkus dh
vuqefr ugh nh tk;sxhA
20,-1-3 iwfjr dk;Z ftldk Hkwxrku **lkexzh o Je** dh njksa esa
gksuk gS] mldh eki nks pj.kksa esa gksxh] vFkkZr~ lM+d feykos
vkfn dh] eki ij 20,-1-2 ds vuqlkj pVVksa esa] ekiuk
rFkk iwfjr dk;Z dh ekiA iwoZ pj.k ;g lqfuf'pr djus
dsa fy, vko';d gS fd visf{kr lkexzh okLRkfod :i ls
laxgz hr dh xbZ gs RkFkk lgh vkdkj dh gS] tSlk fd crk;k
x;k gSA pV~Vs vkfn dh eki ek= ls Bsdns kj vius vki dks
bl mkjnkf;Ro ls foeq[k ugha j[k ldrk fd lkexzh dh
vkiwfrZ fn;s x;s funs'kksZ o visf{kr ifjeki ds vuqlkj gS
rFkk ;fn /kUkRo vkfn dh izkfIr ds fy,] vfrfjDr lkexzh
dh vko';drk eglwl gksrh gS] rks mldh O;oLFkk] ljdkj
ij fcuk vfrfjDr Hkkj Mkys Bsdsnkj dks djuh gksxhA
20,-2 njs a
20,-2-1 gkFk }kj njslh%& bu njksa esa] dks.kksa ;k fdukjksa vkfn esa
tgka jksyj dke ugha dj ldrk] gkFk ls njslh djuk
'kkfey gSA

FORMATION, SUB-GRADE, BERMS, ETC.


fupyh Lrg] iVjh vkfn dh CkukoV
(a) Earthwork shall be measured under Section 3 Earthwork.
(b) Rolling of formation shall be measured under item
20027.

d fehs dk;Z dks [kaM&3 ds vUrxZr **fehs dk;Z** esa ekik tk;sxkA
[k jksyj dk dk;Z en 20027 esa ekik tk;sxkA

434

SECTION 20A

SECTION 20AROAD WORK


[k.M 20,&lM+d dk;Z
FORMATION, SUB-GRADE, BERMS,ETC
fupyh Lrg] iVjh vkfn dh cukoV
(a) Earthwork shall be measured under Section 3 - Earthwork.
(b) Rolling of formation shall be measured under item 3707.

d feh dk;Z dks [kM&3 ds vUrxZr ^^feh dk;Z^^ esa ekik tk;sxkA
[k jksyj dk dk;Z en 3707 esa ekik tk;sxkA

SOLING (SUB-BASE)
ry vk/kkj Ckukuk
When the work is done in two layers, each layer shall be
measured separately.
PER 10 SQUARE
METRES
20001 Soling (or sub base) with
broker boulders or
quarried stone, inter stices
filled, surface formed and
rolled and consolidated to
required gradient and

camber
20002 Ditto but 'except material'

PER 10 SQUARE
METRES

20003 Soling (or sub base) of well


burnt soling bricks
including filling of
interstices and rolling
20004 Ditto but except material

tc dk;Z nks ijrh gks rks izR;sd ijr izFkd ekih tk;sxhA

izfr 10 oxZ ehVj

Spread thickness in mm

QSyko ?kuRo feeh essa


100

150

200

Rs.

Rs.

Rs.

827.50

1203.60

1675.70

185.70

263.00

392.00

Old size
Old size
bricks, one
bricks, one
layer laid flat layer, laid
on edge

Modular
bricks, one
layer, laid
flat

iqjkus ukih;
bZV dh ,d
likV ijr

iqjkus ukih;
bZV dh ,d
[kM+h ijr

NksVh bZVksa
dh ,d
likV ijr

Rs.

Rs.

Rs.

1200.10

1726.40

126.40

185.40

20001 rYyk cukbZ ;k ry vk/kkj


VwVs iRFkj ;k [knkuh iRFkjksa
ls njkjksa esa HkjkbZ djds cuh
lrg ij jks y j pykdj

visf{kr <ky o mHkkj ij njslh


20002 mi;qZDr] fdUrq lkexzh jfgr

izfr 10 oxZ ehVj

20003 rYys cukbZ v/k% vk/kkj ds


fy, iw.kZ nX/k bZVksa dh njkj

HkjkbZ o dqVkbZ lfgr HkjkbZ


20004 iwoksaDr] fdUrq lkexzh jfgr

GRANULAR SUB BASES & LIGHT WEARING SURFACES


nkusnkj ry vk/kkj vkSj de th.kZ lrgsa
The rates for granular sub base and light wearing surfaces are
with low grade aggregates.

nkusnkj ry vk/kkj o de th.kZ lrgksa dh ;g njsa] fuEu dksfV ds


feJ.k ds fy;s gSaA

435

SECTION 20A

SECTION 20AROAD WORK


[k.M 20,&lM+d dk;Z
GRANULAR SUB BASES & LIGHT WEARING SURFACES Contd...
nkusnkj ry vk/kkj vkSj de th.kZ lrgsa tkjh...
Spread thickness in mm

PER 10 SQUARE METRES

izfr 10 oxZ ehVj

QSyko ?kuRo feeh essa


75
Rs.

100
Rs.

320.30

465.80

612.00

335.00

488.00

641.40

20007 Moorum/Red bajri, ditto

20008 Sand, ditto

276.30

399.90

523.90

20009 All as per items 020005 to


020008-A but except

materials

41.30

47.40

53.90

20005 Kankar or laterite, spread,


rolled and consolidated to
gradient and camber
required
20006 Shingle or gravel ditto

50
Rs.

20005 dadj ;k thjk jksMh+ QSykdj jksyj


ls visf{kr <ky o mHkkj ij njslh
djuk
20006 ctfj;k thjk ;k NksVs iRFkj mi;qDZ r
20007 ewje@yky ctjh] mi;qZDr
20008 ckyw] mi;qZDr
20009 lc oSlk gh tSlk en 020005 ls
020008, esa fdUrq feJ.k jfgr

WATER BOUND MACADAM (WBM) SUB BASE & BASE COURSES


ty Ck) jksM+h tCkj v/k% vk/kkj rFkk vk/kkj Lrj
(a)
(b)
(c)

The thickness measured shall be the compacted finished


thickness.
The rates include forming clay puddle bunds (retaining
fillets) on both edges of spread aggregate.
When work is done in two layers, each layer shall be
measured separately.
PER 10
METRES

d
[k
x

ekih x;h eksVkbZ] laiwfjr <ksl eksVkbZ gksxhA


bu njksa esa feykos ds QSyko ds pkjksa vksj] feV~Vh xkjs ds
ca/k /kkjd ifV~V;kn cukuk] 'kkfey gSA
tc dk;Z nks ijrh gks rks izR;sd ijr izFkd ekih tk;sxhA

Type of aggregate

SQUARE

izfr 10 oxZ ehVj

feykCks ds izdkj
Limestone,
sand stone,
Flint or
Quartzite

Kankar Broken
or
brick
Laterite

l[r iRFkj pwuk iRFkj@


f'kyk ;k ckyw iRFkj
Hkwjh pou l[r ;k
[knkuh iRFkj

dadj ;k jksM+h bZV


thjk jksM
a h+

Rs.
822.50

Rs.
759.50

Rs.
685.50

153.20

148.40

112.50

573.20

526.70

469.10

20012 Ditto, except materials


20013 10cm thick (compacted
thickness) WBM with
coarse aggregates of
grading 1 (90 to 40mm
size), spread, rolled and
consolidated to gradient

and camber required

109.60

109.60

82.50

1094.40

1012.60

959.80

20014 Ditto except materials

190.10

190.10

149.60

20010 7.5cm thick (compacted


thickness) WBM, with
coarse aggregates of
grading 2 (63 to 40mm
size) or of grading 3 (50
to 20mm size), spread,
rolled and consolidated
to gradient and camber

required

20011 Ditto, except materials


20011A All as per item 20010

but 50mm thick

Granite,
trap or
Basalt

Rs.

20010 7-5 lseh eksVh l?ku eksVkbZ


tcj Js.kh 2 63 ls 40 feeh
vkdkj ;k Js.kh 3 50 ls 20
feeh vkdkj ds eksVs feykok
QSykuk] ij jksyj pykdj
visf{kr o mHkkj ij njslh
djds lekfgr
20011 mi;qZDr] feykos dks NksM+dj
20011A lHkh en 20010 tSlk fdUrq
50 feeh eksVk
20012 mi;qZDr] feykos dks NksM+dj
20013 10 lseh- eksVh ?kuh eksVkbZ
tcj] dksfV 1 vkdkj&90 ls
40 feeh eksVs feykcs lfgr
QSykuk] jksyj ls dqVkbZ djds
visf{kr <ky o mHkkj ij njslh
djds lekfgr
20014 mi;qZDr] feykos dks NksM+dj

436

SECTION 20A

SECTION 20AROAD WORK


[k.M 20,&lM+d dk;Z
PREPARATION OF SURFACES PRIOR TO APPLICATION OF PRIMER
ijr yxkus ls igys lrg dks lWokjuk
PER 10 SQUARE
METRE
20015 Preparing surfaces by
brushing with wire
brushes for removing
caked mud etc. sweeping with brooms and
finally fanning the
cleaned surface with
gunny bags to remove

all loose dirt etc.

izfr 10 oxZ ehVj

Unsurfaced water
bound macadam

Black top
surfaces

vle tyCk) jksM+h

dkyh ijh lrg

Rs.

Rs.

109.20

65.50

20015 teh gqbZ feh vkfn dks yksgs ds cz'q kksa


ls jxM+dj lkQ djuk] >kMw yxkuk
rFkk vUr esa lrg dks cksfj;ksa ls gok
djds lHkh <hyh xnZ vkfn dks gVkdj
lrg dks laokjuk

PRIMING SURFACES
ijrh lrg
Preparation of surface prior to application of primer etc. shall
be measured only once when priming coat is preceded by a
tack coat.
PER 10 SQUARE
METRE
20016 Applying evenly a
priming/tack coat with
bituminous primer at 10

kg per 10 sq metre
20017 Add/deduct from item
20016 for each extra/ less

kg of primer used

ijr vkfn fcNkus ls igys lrg laokjus dks dsoy ,d ckj ekik
tk;sxk] tc vLrjh ijr ls vklatd ijr }kjk vuqxkfer gksxhA
Except
bitumen

M & L using

lkexzh o Je iz;ksx

izfr 10 oxZ ehVj

Q'khZ rkjdksy

uenk rkjdksy

Rs.

Rs.

429-50

441-30

rkjdksy
jfgr 20016 le:i ls 10 fd xzke izfr 10
oxZehVj ds fglko ls rkjdksyh
Rs.
vklatd yxkuk
47-70

44-10

20017 en 20016 esa tksMsa@?kVk;sa] izfr


fd-xzke vf/kd@de vLRkj iz;ksx
ds fy;s

Paving bitumen Cutback bitumen

43-00

4-80

BITUMINOUS SURFACE DRESSING

rkjdksyh lrg dh njslh djuk


(a) Preparation of surface, priming coat, and filling in potholes
in repairs, if any, prior to spraying shall be measured
separately.
(b) Adjustment in quantities of binder and chippings shall be
made under items 20021 and 20022 respectively.

lrg dh lTtk] vLrjh ijr rFkk ejEer esa xM<+kas dh HkjkbZ]


;fn gks rks og fNM+dko ls igys izFkd ekis tk;saxsA

[k

ca/kkbZ o NaVkbZ dh ek=k esa lek;kstu e'k% en 20021 o


20022 esa fd;k tk;sxkA

SECTION 20A

437

SECTION 20A ROAD WORK


[kaM 20,&lM+d dk;Z
UNSURFACED SURFACES OF WBM
tcj dh vle lrgsa
PER 10 SQUARE METRE

M&L

Except
binder

20018 Surface dressing by spraying lk- o Je


evenly paving bitumen at 20
kg per 10 sq metres, blinding
with 12.5mm stone chippings
@ 0.14cu.m per 10 sq.m. and
Rs.
rolling to required gradient
969.00
and camber
20019 Surface dressing in two coats,
with the following materials
per 10 sq metres and rolling to
required gradient and camber

First
Second
coat
coat
Paving
20 kg
12 kg
bitumen
1579.40
Chippings 0.14 cu.m 0.10 cu.m.
Stone
(size 12.5 (size 10 mm)
mm)

jksMh+ jfgr
Rs.
205.20

360.20

RENEWAL COAT ON
BLACK TOP SURFACES
PER 10 SQUARE METRES
20020 Surface dressing, renewal coat,
by spraying evenly paving
bitumen at 12 kg per 10 sq
metres, blinding with 10 mm
stone chipping @ 0.10 cum per
10 sq metres and rolling to

required gradient and camber

PER 10 SQUARE METRES


20021 Add to or deduct from any of
the items for surface dressing
for variation in the quantity of

paving bitumen per kg


PER 10 SQUARE METRES
20022 Add to or deduct from any of
the items for surface dressing
for variation in the quantity of

chippings per 0.01 cum

izfr 10 oxZ ehVj

Except binder
and stone
chippings

20018 20 fdxzk- izfr 10 oxZeh ds fglkc ls


fpidk dksyrkj dk fNM+dko rFkk 12-50
feeh iRFkj dh dkjksa ls 0-14 ?keh
jksMh+ o dkjkas jfgr
izfr 10 oeh ds fglkc ls HkjkbZ djrs
Rs.
gq, jksyj pykdj visf{kr <ky o
132.50
mHkkj ykrs gq;s lrg laokjuk]
20019 nks ijr dh lrg lTtk] izfr 10 oeh
jksyj pykdj visf{kr <ky o mHkkj
ykus ds fy, fuEu lkexzh iz;ksx djds
igyh ijr
nwljh ijr
12 fdxzk
Q'khZ rkjdksy 20 fdxzk
0-14 ?keh
0-10 ?keh
drju
(12-5 feeh
(10 feeh
(iRFkj dh)

vkdkj
)
vkdkj)
271.50

dkyh ijh lrg ij uohuhdj.k ijr


izfr 10 oxZ ehVj
20020 lrg lTtk ij uohuhdj.k ijr 12
jksMh+ jfgr
fdxzk izfr 10 oxZ eh ds fglkc ls le
jksMh+ o dkj jfgr
Q'khZ rkjdksy dks 12 fd xzk izfr 10
oeh ds fglkc ls iRFkj dh dkj 0-10
Rs.
Rs.
?keh izfr 10 oeh jksyj ls visf{kr
<ky ls HkjkbZ o mHkkj ykrs gq;s fcNkuk
149.20
112.90

M&L

Except
binder

lk- o Je

Rs.
607.40

Except binder
and stone
chippings

M&L

Except binder

lk- o Je

iRFkj jfgr

Rs.

Rs.

41.60

3.40

izfr 10 oxZ ehVj


20021 tksMas+ ;k ?kVk;s]a fdlh Hkh lrg laokjh
dk;Z dh njksa esa izfr fdxzk Q'khZ
rkjdksy dh ek=k ds fopj.k ij
izfr 10 oxZ ehVj

Size of chipping

drju dk vkdkj
12.5mm
Rs.

10mm
Rs.

5.70

5.80

20022 tksM+sa ;k ?kVk;sa] lrg dks laokjus dh


njksa esa ;k izfr 0-01 ?keh ds fglkc ls
dkjksa esa vk;s fopj.k ij

438

SECTION 20A

SECTION 20A ROAD WORK


[kaM 20,&lM+d dk;Z
BITUMINOUS CARPET
rkjdks y h xyhpk
(a) Preparation of surface and priming/tack coat shall be
measured separately.

(b) Seal coat shall be measured separately.

[k
Binder

PER 10 SQUARE METRES

Except
binder

ysbZ
20023 Bituminous premixed carpet,
2cm consolidated thickness,
with 0.27 cu.m. of stone
chippings mixed with 14.6 kg of
binder, rolled and compacted to

required camber and gradient


20024 Add to item 20023 for each
additional kg of bitumen

lrg dh laokj rFkk vLrjh@vklatd ijr izFkd ls ekih


tk;sxa hA
Nkih ijr izFkd ekih tk;sxhA

ysbZ jfgr

Paving
bitumen

Cut back
bitumen

Q'khZ
rkjdksy

uenk
rkjdksy

Rs.
1041.00

Rs.
1058.60

Rs.
468.10

41.60

42.70

3.40

izfr 10 oxZ ehVj


20023 2 lseh Bksl eksVkbZ dh iwoZ fefJr
rkjdksyh xyhpk lkFk esa 0-27 ?keh
iRFkj dkj 14-6 fdxzk ca/kd feJ.k
esa QSykuk rFkk <ky o mHkkj Bhd
djrs gq, jksyj ls njslh djuk
20024 tksMsa+] en 20023 esa] izfr fdxzk
vfrfjDr rkjdksy gsrq

SEAL COAT
lhy ijr
PER 10 SQUARE METRES

izfr 10 oxZ ehVj

Binder

ysbZ

20025 Premixed sand seal coat with


0.06 cu.m. of sand mixed with 6.8 Paving bitumen Cut back bitumen
Q'khZ rkjdksy
uenk rkjdksy
kg of bitumen, applied and rolled
Rs.
Rs.
to a uniform smooth surface
330.70
425.70
20026 Liquid seal coat, applying
evenly binder @ 9.8 kg per 10
sqm blinding with 6.3mm size
stone chippings @ 0.09 cum per
l0 sqm and rolled to a uniform

smooth surface

20025 iwoZ fefJr ckyw lhy ijr] 0-06 ?keh


ckyw 6-8 fdxzk rkjdksy esa feykdj]
fcNkdj jksyj ls le o ,dlkj lrg
laifw rZ
20026 9-8 fdxzk izfr 10 oeh ?kksy o 6-3
feeh dh 0-09 ?keh iRFkj dh dkj izfr
10 oeh ds fglkc ls feys ?kksy dh
lhy ijr leku :i ls QSykdj jksyj
ls ,dlkj ,oa le lrg cukuk

ROLLING
dqVkbZ djuk jksyj dk;Z
(a) Payment under an item of this table shall be made only where
rolling is not otherwise included or provided for.

(b) The minimum area of power rolling, with one specified


weight of roller, which will be paid for under this table will
be 200 sq.m. This area shall comprise all areas rolled
irrespective of the schedule items under which they are
ordered, provided that the items are referred to in the Work
Order, and the rolling is within a radius of half km. In
such a case, adjustment shall be made for the allowance for
rolling, if any, included in other Schedule items. If an area
or an aggregate area is less than 200 sq metres, then pay
ment will be made for 200 sq metres.

[k

bl lwph dh nj esa dsoy rHkh Hkqxrku gksxk tc jksyj dk;Z


vU;= lekfgr ;k mldk izko/kku ugha gksxkA
,d fu/kkZfjr ctu okys 'kfDr }kjk pkfyr jksyj ftldk Hkqxrku
bl lwph ds vUrxZr gksxk mldk de ls de {ks= 200 oeh gksxkA
bl {ks= esa og lc {ks= lfUufgr gksx
a s tgka og pyk gS fcuk
vuqlp
w h dh ml en dh vis{kk ds ftlds fy, vkns'k gS] c'krsZ
fd og nj dk;kZn's k ls lanfHkZr gks rFkk jksyj dk;Z vk/kk fdeh
dh ifjf/k esa gksA bl izdkj ds ekeys esa ;fn dqVkbZ dksbZ gS rks
mldk lek;kstu Hkh dqVkbZ dss :i esa bl vuqlp
w h dh vU; njksa
esa fd;k tk;sxkA ;fn ,d {ks= ;k lekfgr {ks= 200 oeh ls de
gS] rks Hkqxrku 200 oxZ ehVj ds fy, gksxkA

SECTION 20A

439

SECTION 20A ROAD WORK


[kaM 20,&lM+d dk;Z
ROLLING Contd...
dqVkbZ djuk jksyj dk;Z tkjh
(c) The rates for rolling include for watering as necessary and
consolidating to the required level, gradient or camber,
keeping roller wheels wet, if required, filling in hollows
and depressions (any material being supplied by the M.E.S.,
or paid for as 'Supplied only') and the provision of water,
animals, drivers, crew, fuel, labour, tools, etc.

(d) Each course or layer rolled shall be measured.

?k

PER 10 SQUARE
METRES

Hand
roller 0.2
to 0.5
tonne

gkFk jksyj
0-2 ls 0-5
Vu rd

20027 Rolling and consolidating


formation
surfaces in cutting
20028 Soling
of
broken
boulders or quarried
stone, not exc 15cm

thickness
20029 Soling of bricks and light
wearing surfaces with
low grade aggregates
of sand, moorum or red
bajri, any thickness
20030 Water bound macadam
(except laterite, kankar
and broken brick
aggregates) exc 100mm
compacted thickness
20031 Ditto but of laterite,
kankar and broken

brick aggregates

^jksyj ls dqVkbZ ls *dqVkbZ dh njksa esa lekfgr gS] vko';drkuqlkj


ikuh nsuk rFkk visf{kr lrg] <yku] mHkkj dh njslh] jksyj
ds ifg;ksa dks xhyk j[kuk rFkk ;fn vko';d gks rks fjfDr;ksa
;k fupkbZ dh HkjkbZ djuk ,e bZ ,l }kjk dh xbZ vkiwfrZ
;k *dsoy vkiwfrZ* ds :i esa Hkqxrku dh xbZ dksbZ lkexzh
rFkk ikuh] i'kq] pkyd] deZpkjh] bZ/a ku] Jfed] vkStkj vkfn
dk izcU/k djukA
izR;sd vLrj ;k ijr] jksfyr dh eki dh tk;sxhA

Vu rd

2 ls 5
5 ls
8 ls
Vu rd vf/kd o vf/kd o
8 Vu ls 12 Vu
vuf/kd ls vuf/kd

Rs.

Rs.

Rs.

Rs.

Rs.

18.20

16.50

5.60

6.80

8.00

24.30

29.30

16.00

izfr 10 oxZ ehVj

Animal
Power roller
roller 0.8
'kfDr jksyj
to 1.50
Exc 2
Exc 5
Exc 8
tonne tonne & tonne & tonne &
i'kq jksyj n exc 5 n exc 8 n exc 12
0-8 ls 1-5 tonne tonne
tonne

15.20

4.00

38.00

69.50

20.50

55.10

20027 dkVksa esa jksyj ls njslh djds


lrg laokjuk

20028 VwVs iRFkjksa ;k [knku ds iRFkjksa


dh 15 lseh ls vuf/kd ?kuRo
esa HkjkbZ

20029 fuEu dksfV ckyw] eqje ;k


yky ctjh fdlh ?kuRo ds
feykos ls bZVksa vkSj gYdh
th.kZ lrgksa dh rYysnkjh djuk
20030 tyc) iRFkj dh jksMh+ thjk]
dadM+ o bZV feykos dks
NksM+dj 100 feeh vf/kd
dh Bksl eksVkbZ esa HkjkbZ djuk
20031 iwoksZDr] fdUrq] thjk] dadM+
o bZV jksM+h feykok

440

SECTION 20A

SECTION 20A ROAD WORK


[kaM 20,&lM+d dk;Z
ROLLING-Contd...
dqVkbZ djuk jksyj dk;Z tkjh
Table contd.
PER 10 SQUARE
METRES
20032 Bituminous macadam
surfaces, any thickness
20033 Thin bituminous carpet,

2cm thick
20034 Gritted or blinded surfaces
after spraying as in surface
dressing or seal coat

Rs.

Rs.

Rs.

Rs.

Rs.

21.30

35.20

30.80

6.70

12.20

20.90

13.80

4.30

7.30

14.10

izfr 10 oxZ ehVj


20032 fdlh eksVkbZ dh rkjdksyh
iDdh lrg
20033 2 lseh- eksVs irys rkjdksyh
xyhps ij
20034 fdjfd'k ;k ja/kh lrgksa ij] QSykcs
ds ckn tSlk fd lrgh laokj ;k
lhy ijr ij gksrk gS

SCREENING ROAD METAL, ETC.

vkoj.kh ctjh lM+d


izfr ?ku ehVj

Rs.

PER CUBIC METRE


20035 Screening road metal, Chippings, etc. on the
site of the work, when specially ordered,
including removing screened materials clear
of screen and stacking in separate heaps for
measuring (Materials from both sides of

screen measured)

69.50

20035 vkoj.kh ctjh lM+d] dkj vkfn dk;ZLFky ij tc


fo'ks"k:i ls dgk x;k gks rFkk vkojrh lkexzh dks
gVkdj vkoj.k lkQ djuk rFkk eki ds fy, izFkd
pV~Vksa esa yxkuk lfgr lkexzh vkoj.k ds nksuksa
vksj ls ekih tk;sxh

BREAKING STONE, BOULDER, ETC.

iRFkj] f'kyk[kaM vkfn dh rqM+kbZ


(a) The rates include removing the broken stone or boulders to a
distance not exc 50 metres from the crusher if a crusher is
used and stacking in regular heaps for measurement.
Measurements shall be taken of the stacked materials after
breaking.
(b) The crusher shall be installed at the place indicated by the
E.I.C. and the materials for breaking shall be delivered by
the MES within 50 metres of the crusher.

(c) The smaller stuff produced in breaking or crushing is not


to be screened out unless ordered. If ordered to be screened,
screening will be paid for under item 20035 in addition.

(d) The rates are not applicable if stone or boulders for breaking
is supplied by the contractor.

?k

[k

bu njksa esa wlj ;fn iz;ksx fd;k gS] ls 50 eh- ls vuf/kd


nwjh rd VwVs iRFkjksa ;k f'kyk[kaMksa dks gVkuk rFkk eki ds fy;s
fu;fer pV~Vksa esa yxkukA pV~Vksa esa yxkbZ lkexzh dh rksM+us
ds ckn eki yh tk;sxhA
wlj izHkkjh vfHk;ark }kjk fu/kkZfjr LFkku ij LFkkfir fd;k
tk;sxk rFkk rksMu+ s dh lkexzh dh vkiwfrZ 50 eh- dh ifjf/k ds
vUnj ,ebZ,l }kjk dh tk;sxhA
rqM+kbZ ;k dVkbZ esa fudys NksVs inkFkZ dks tc rd vkKk u
gks] vyx ugha fd;k tk;sxkA ;fn NaVkbZ dh vkKk nh tkrh
gS rks mldk vfrfjDr Hkqxrku en 20035 ds vUrxZr gksxkA
;g njsa ykxw ugha gksxh ;fn rksMu+ s ds fy, iRFkjksa ;k f'kykvksa
dh vkiwfrZ Bsdsnkj us dh gSA

441

SECTION 20A

SECTION 20A ROAD WORK


[kaM 20,&lM+d dk;Z
BREAKING STONE, BOULDER, ETC.Contd...

iRFkj] f'kyk[kaM vkfn dh rqM+kbZ tkjh


PER CUBIC METRE

Granite, Trap or Lime stone, sand


Basalt or mate- stone or Quartzite
rial of similar or material of similar
hardness
hardness

dBksj xzsukbV
cslkYV ;k ,slh gh
dBksj lkexzh
Rs.

Brick or Kankar, Latmaterial erite or mateof similar rial of similar


hardness
hardness

pwuk] ckyqbZ ;k
bZV ;k dadM+] thjk ;k
[knkuh ;k ,slh gh leku dBksj ,slh gh dBksj
dBksj lkexzh
lkexzh
lkexzh
Rs.

Rs.

20036 Breaking stone or


boulders to 63 mm

gauge
20037 Ditto, to 50mm

gauge

106.80

84.90

77.40

69.00

20038 Ditto, to 40mm

gauge

116.80

95.60

84.90

74.30

122.10

97.70

87.10

79.60

138.00

111.50

100.90

90.20

153.90

122.10

111.50

100.90

129.90

123.40

116.80

104.60

20039 Ditto, to 25mm

gauge
20040 Ditto, to 20mm

gauge
20041 Ditto, to 12.5 mm

gauge
20042 Ditto, to 6.3mm

gauge

izfr ?ku ehVj

20036 iRFkj ;k f'kyk dks 63


feeh xst rd rksMu
+k
20037 mi;qZDr] 50 feeh
xst rd
20038 mi;qZDr] 40 feeh xst
rd
20039 mi;qZDr] 25 feeh
xst rd
20040 mi;qZDr] 20 feeh
xst rd
20041 mi;qZDr] 12-5 feeh
xst rd
20042 mi;qZDr] 6-3 feeh
xst rd

REPAIRS TO SURFACES OF MACADAM ROAD

iDdh jksM+h dh lM+d dh lrg ejEer


d bu njksa esa ;kaf=d 'kfDr ;k gkFk ls [kqjpuk 'kkfey gSA
(b) The items for scarifying include raking over and grading [k [kqjpus dh enksa esa [kkaps cukuk VwVh lrg esa visf{kr mHkkj
the broken up surfaces to the proper camber etc. as required.
vkfn rd ykuk 'kkfey gSA
(c) The rates for potholes not exc 1 sq metre each apply to x 1 oeh ls vuf/kd ds xM~<ksa dh ejEer] iqu% fcNkbZ esa lfEEkfyr
repairs carried out in connection with respraying. Any
gSa A 0-1 oeh ls de ds xM~<ksa dks 0-1 oeh ekik tk;sxkA
(a) The rates include for scarifying by power or by hand picking.

pothole less than 0.1 sq. metre will be measured 0.1 sq metre.
(d) Repairs to potholes and patches exceeding 1 sq metre each
and aggregating 40 sq metres or more within a radius of
half km whether carried out in connection with respraying
or not will be paid for at the rates for new work. When the
area of such potholes and patches agregates to less than 40
sq metres and more than 20 sq m within a radius of half
km. 20 per cent will be added to the rates for new work.

?k

(e) The stone aggregates and chippings for filling potholes,


etc. shall be of the same material as in the existing surface.

M+

(f) Breaking through macadam surface for pipe trenches, etc.


shall be measured under Section 3Earthwork. Making
good such surfaces shall be paid for at the rates for new
work or for potholes and patch repairs according to the
area made good.

,d oeh ls cM+s xM~<ksa ;k isou rFkk feykdj 40 oeh ;k vf/kd


vk/kk fdeh ifjf/k ds vUnj ;k pkgs og iqu% fcNkbZ esa fy,
x, gksa ;k ugha] mudk Hkqxrku uohu dk;Z esa gksxkA tc ,sls
xM~<ksa ;k psfi;ksa dk {ks= lfEefyr :i ls 40 oeh ls de gks
rFkk vk/kk fdeh dh ifjf/k esa 20 oxh- ls vf/kd gks rks uohu
dk;Z njksa esa 20 izfr'kr tksM+k tk;sxkA
xM<ksa vkfn dh HkjkbZ ds fy, iRFkj dk feykok vkSj dkj
fo|eku lrg ds vuq:i lkexzh ds gksaxsA
uyksa o [kkb;ksa ds fy, iRFkjh lM+d dh [kqnkbZ dh eki
[kaM&3 Hkwfe dk;Z ds vUrxZr gksxhA ,slh lrgksa dks Bhd djus
ds dk;Z dk Hkqxrku uohu dk;Z dh njksa esa ;k Bhd fd;s dk;Z
ds {ks= ds vuqlkj xM~<ksa o isou ejEer dk;Z esa gksxkA

442

SECTION 20A

SECTION 20A ROAD WORK


[kaM 20,&lM+d dk;Z
REPAIRS TO SURFACES OF MACADAM ROADSContd...
iRFkj dh jksM+h dh lM+d dh lrg ejEer tkjh...
PER 10 SQUARE METRE

N exc 50
mm deep

Exc 50 mm and n
exc 100 mm deep

izfr 10 oxZ ehVj

xgjkbZ 50
xgjkbZ 50 feeh ls
feeh vuf/kd vf/kd o 100 feeh
20043 400 oeh ls vf/kd ds {ks= esa iRFkjh
ls vuf/kd
20043 Scarifying or picking gravelled,
lM+d ;k rkjdksyh iRFkjh lM+d dks
Rs.
Rs.
macadam or bituminous macadam

[kqjpuk ;k jksMh mBkuk


20.30
28.10

surfaces in area exc 400 sqm


20044 mi;qZDr] 400 oeh vuf/kd {ks= esa

20044 Ditto,in area not exc400 sqm


87.40
152.90
20045 tksMs+ 50 ehVj ls vuf/kd nwjh rd
20045 Add for removing n exc 50 metres

gVkus o pV~Vs yxkus ds fy,


and stacking

PER 10 SQUARE METRE


20046 Repair to potholes any depth, not exc 1
sq m each including sweeping free from
dust and mud, or water, scoring sunken
surfaces in roads, paths, etc. cutting around
edges to at least 25 mm in depth, making
good by filling in screened & graded road
metal, watering and well ramming
(including supply of road metal)
PER 10 SQUARE METRE
20047 All as in item 20046 but making
good by applying tack coat @ 5 kg
per 10 sq m, putting in premixed
bituminous macadam, well
rammed and sealed with binder
9.8 kg per 10 sq m, blinded with
0.09 cu m of stone chippings, 6.3
mm size and again well rammed
(including supply of premixed
macadam, binder and chippings).
depth of potholes exc 30 mm
20048 Ditto, but making good by
applying tack coat with
bituminous primer @ 5 kg per 10
sq m, putting in premix as
specified for thin bituminous
carpet (2 cm thick) well rammed
and sealed with premixed sand
seal coat (6.8 kg of binder with 0.06
cu m of sand), again well rammed
(including supply of premix
binder and sand) depth of

potholes n exc 30 mm

izfr 10 oxZ ehVj

Rs.

367.40

20046 fdlh Hkh xgjkbZ ds xM+<ksa dh ejEer] izR;sd 1 oeh


ls vuf/kd] ?kwy o feV~Vh dks >kMw ls lkQ djuk
;k ikuh ls lQkbZ] fupyh lrg ls eyok gVkuk
vkfn] 25feeh xgjkbZ ds fdukjksa dksa pkjksa vksj
dVkbZ djus rFkk mudh dkjksa o lM+d feykcs ls
HkjkbZ djus ikuh Mkydj eqx
a jh ls lM+d ;k jkLrksa
dh njslh djuk jksMh dh vkiwfrZ lfgr

Paving Using cutback Using


bitumen
emulsion

Q'khZ
rkjdksy
Rs.

1170.70

1046.20

uenk rkjdksy jaxhu /kkrqbZ


Rs.

Rs.

izfr 10 oxZ ehVj


20047 lc cSlk gh tSlk en 20046 esa gS]
fdUrq] iwoZ fefJr rkjdksyh jksMh+ esa 5
fdxzk izfr 10 oeh ds fglkc ls vklatd
ijr fcNkuk vPNh rjg njslh djuk
rFkk 9-8 fdxzk izfr 10 oeh ds fglkc ls
HkjkbZ 0-09 ?keh dh dkjksa ls 6-3 feeh
vkdkj esa Hkjrs gq, lhy ijr yxkuk
fQj vPNh rjg dqVkbZ djuk iwoZ fefJr
jksMh+] ?kksy o dkjksa dh iwfrZ lfgr
xM~<ksa dh xgjkbZ 30 feeh ls vf/kd
20048 mi;qDZ r] fdUrq vklatd ijr] 5 fdxkz
izfr 10 oeh iwoZ feJ.k esa feykdj
tSlk fufnZ"V gks iryk rkjdksyh xyhpk
2 lseh eksVk ijr Mkyuk vPNh njslh
djuk rFkk iwoZ fefJr ckyw dh lhy
ijr yxkuk 6-8 fdxkz ysbZ esa 0-06
?keh ckyw fQj njslh djuk iwoZ fefJr
ysbZ o ckyw dh iwfrZ lfgr] xM~<k+ as dh
xgjkbZ 30 feeh ls vuf/kd

443

SECTION 20A

SECTION 20A ROAD WORK


[kaM 20,&lM+d dk;Z
REPAIRS TO SURFACES OF MACADAM ROADS Contd...

iRFkj dh jksM+h dh lM+d dh lrg ejEer tkjh


PER 10 SQUARE METRE

izfr 10 oxZ ehVj

20049 Add to items 20046, 20047 & 20048 executed

not in connection with respraying.

33.33%

20049 tksM+sa] en 20046] 20047 o 20048 esa] iqu% fNM+dko


ds laca/k esa laiUu ugha

MATERIALS (Supplied only)

lkexzh dsoy vkiwfrZ


The rates for aggregates, etc., include stacking materials in
regular stacks for measurement

feykcs vkfn dh njksa esa ekius ds fy, lkexzh dks fu;fer pV~Vksa
esa j[kuk fufgr gSA
HkjkbZ ds fy;s iRFkj@bZV

BRICKS/STONE FOR SOLING


PER CUBIC METRE

Rs.

20050 Quarried rubble stone or broken nullah


boulders, in large pieces for soling/sub
base of road, etc.

558.10

PER 1000 NOS.


20051 Soling bricks, old size

2526.20

20052 Soling bricks, modular size

2467.50

izfr ?ku ehVj


20050 [knkuh iRFkj ds VqdM+sa ;k VwVs gq, uqYyk f'kyk cMs+
VqdM+ks esa fcNkus@lM+d dh fupyh lrg vkfn ds
fy,
izfr 1000 la[;k
20051 iqjkus vkdkj dh ryh; bZVsa
20052 NksVs cM+s vkdkj dh ryh; bZVsa

LOW GRADE AGGREGATES

fuEu dksfV dk feykok

PER CUBIC METRE

izfr ?ku ehVj


558.10

20053 Kankar
20054 Shingle or gravel

20055 Laterite

20056 Moorum/Red bajri

323.10
470.00

20057 Sand

558.10

352.50

20053
20054
20055
20056
20057

dadM+
thjk ;k iFkjh
jksMh+
ewje@yky ctjh
ckyw

444

SECTION 20A

SECTION 20A ROAD WORK


[kaM 20,&lM+d dk;Z
MATERIALS (Supplied only)

lkexzh dsoy vkiwfrZ


AGGREGATE FOR WBM

Granite, Limestone, Sand Kankar Broken


Trap or stone, Flint or
or
brick agBasalt
Quartzite
Laterite gregate

PER CUBIC METRE

20058 Coarse aggregates, grading l,


90 to 40 mm size or grading

2, 63 to 40mm size
20059 Ditto, grading 3, 50 to 20 mm

size

tcj dk feykok
izfr ?ku ehVj

dBksj
pwuk] ckyw iRFkj ;k dadj ;k bZV jksMh
VqdMs+ ;k
[knkuh
jksMh+
feJ.k
jksMh+
Rs.

Rs.

Rs.

587.50

540.50

505.20

587.50

540.50

505.20

20058 eksVk feykok] dksfV 1] vkdkj 90


ls 40 feeh ;k dksfV 2 vkdkj
352.50
63 ls 40 feeh
20059 iwoksZDr] dksfV 3] vkdkj 50 ls
352.50
20 feeh
Rs.

BROKEN STONES AND CHIPPING FOR BITUMEN WORK

rkjdksy ds dk;Z ds fy, VwVs iRFkj vkSj dkysa

20060 Coarse aggregates of


nominal size for

izfr ?ku ehVj

Bituminous Surface dressing and Liquid seal


macadam
premixed carpet
coat
rkjdksyh jksM+
lrg laokjuk o iwoZ
lhy ijr ?kksy
fefJr xyhpk

PER CUBIC METRE

25 mm

12.5mm

10 mm

6.3 mm

Rs.

Rs.

Rs.

Rs.

326.60

353.70

363.00

391.30

PER CUBIC METRE

Rs.

20061 Coarse sand suitable for use with bitumen

291.70

20062 Pea gravel 10mm size

293.70

20060 lkekU; vkdkj dk eksVk feykok

izfr ?ku ehVj


20061 rkjdksy esa feykus ;ksX; eksVh ckyw
20062 NksVh jksM+h vkdkj 10 feeh

BITUMEN

rkjdks y

PER TONNE OF MATERIALS

lkexzzh dk izfr Vu

20063 Paving bitumen, any penetration, in


cluding containers

20063 fdlh Hkh izos';rk dk Q'khZ rkjdksy MCcs lfgr

38187.50

20064 Cut-back bitumen, any type and grade, ditto

39362.50

20065 Bitumen emulsion, any type and grade

ditto

51700.00

20064 fdlh Hkh uewus o dksfVdk uenk rkjdksy] mi;qDZ r


20065 fdlh Hkh uewus o dksfV dk /kkrqbZ rkjdksy] mi;qDZ r

445

SECTION 20B

SECTION 20BROAD WORK


[k.M 20ch&lM+d dk;Z
HARD STANDING AND PAVEMENT
iDds [kaMts vkSj iVfj;ka
20.B.1
Measurements
20.B.1.1 Measurements shall be taken of the net finished
work, except where otherwise stated.
20.B.1.2 Measurements of materials like stone,
aggregates, screenings, sand etc. shall be taken
in bottomless boxes or measuring boxes or in
closely packed stacks on level ground. While
no special compaction is necessary by ramming/
shaking or hammering, no attempt at loose
stacking will be permitted.
20.B.1.3 Measurements for finished work for which
Materials and Labour rates are to be paid shall
be taken in two stages, viz. measurements of
road aggregates etc., in stacks as stated in 20.B.
1.2. above and measurements of the completed
work. The former is necessary to ensure that the
required quantities of road aggregates have
actually been collected and are of the sizes, etc.
indicated. Stack measurements shall not,
however, absolve the Contractor from the
responsibility of conforming to the required
specification and dimensions etc. and provision
of more materials, if necessary, to make up the
thickness, etc. indicated without any extra
charge to Government.

20ch-1
20ch1-1
20ch-1-2

20ch-1-3

eki
fo'kq} laiwfjr dk;Z dh eki yh tk;sxh] tc rd fd
dgha vU;Fkk u dgk x;k gksA
lkexzh tSls iRFkj] feykos] Nkul] ckyw vkfn dh eki]
ryh jfgr] cDlksa] ekih cDlksa ;k lery Hkwfe ij
lVkdj yxk;s pV~Vksa ls yh tk;sxhA gkaykafd fo'ks"k
?kuRo ds fy,] njslh djus@dwVus ;k gFkkSM+k pykus
dh vko';drk ugha gS] fQj Hkh <hys pV~Vs yxkus dh
vuqefr ugha nh tk;sxhA
iwfjr dk;Z ftldk Hkqxrku *lkexzh o Je* dh njksa esa
gksuk gS mldh eki nks pj.kksa esa gksxh vFkkZr~ lM+d
feykos vkfn pVV~ksa esa tSls dh ij 20ch-1-2 esa dgk
x;k gS rFkk iwfjr dk;Z dks ekiukA iwoZ pj.k ;g
lqfuf'pr djus ds fy, vko';d gS fd visf{kr
lkexzh okLRkfod :i ls laxzghr dh xbZ gS rFkk lgh
vkdkj dh gS tSlk fd crk;k x;k gSA pV~Vs vkfn dh
eki ek= ls Bsdns kj vius vki dks bl mkjnkf;Ro ls
foeq[k ugha j[k ldrk fd lkexzh dh vkiwfrZ fn;s x;s
funs'Z kksa o visf{kr ifjeki ds vuqlkj gS rFkk ;fn ?kUkRo
vkfn dh izkfIr ds fy,] vfrfjDr lkexzh dh vko';drk
eglwl gksrh gS rks mldh O;oLFkk] ljdkj ij fcuk
vfrfjDr Hkkj Mkys Bsdsnkj dks djuh gksxhA

BITUMINOUS MACADAM
Mkej dh iDdh lM+d
(a) Preparation of surface and priming/tack coat shall be
measured separately.
(b) Seal coat or wearing coat shall be measured separately.
(c) The rates are worked out on the basis of binder content of
4% by weight of total mix. Any addition or deduction in
binder content used, the rates shall be adjusted as per SI
item 20068.

+ d lrg dks laokjus ds dk;Z vkSj vLrj@vklatd ijr dh eki


izFkd gksxhA
[k lhy ijr ;k /kkjd ijr dh eki izFkd gksxhA
x bu njksa dh x.kuk dk vk/kkj ysih ds vo;o ds 4 izfr'kr dks
feJ.k ds dqy ;ksx Hkkj ls xq.kk djds fudkyk x;k gSA iz;Dq r
ysih feJ.k esa vkbZ fdlh izdkj dh c<+krs jh ;k dVkSrh dks bl
vuqlwph dh en la[;k 20068 ds vuqlkj njksa esa O;ofLFkr
fd;k tk;sxkA

446

SECTION 20B

SECTION 20BROAD WORK


[k.M 20ch&lM+d dk;Z
BITUMINOUS MACADAM
Mkej dh iDdh lM+d

PER CUBIC METRE

Binder content

Except
binder

ysih feJ.k

izfr ?ku ehVj

ysih feJ.k
20066 Premix bituminous,
macadam laid/rolled
and compacted to
required gradient and
camber (consolidated
thickness 75mm or

less)
20067 dobut
consolidated thickness more

than 75 mm

Paving bitumen
any penetration

Cut back
bitumen

psiw Mkej fdlh


izos'k dk

uenk Mkej

Rs.

Rs.

Rs.

4163.10

4245.30

1490.00

4361.70

4443.90

1688.50

20066 iwoZ fefJr Mkej ;qDr jksM+h


fcNkuk@jksyj ls dwVuk rFkk
visf{kr <ky o mHkkj Bhd
djrs gq, Bksl cukuk Bksl
eksVkbZ 75 feeh ;k de
20067 mi;qZDr] fdUrq Bksl eksVkbZ
75 feeh ls vf/kd
izfr fdyksxzke

PER KILOGRAM
20068 Add/Deduct over item
20066 and 20067 for
each extra/less Kg of

binder used

38.20

39.40

20068 tksM+sa ;k ?kVk;sa en 20066


o 20067 esa iz;qDr ysih ds
izR;sd fdxzk vf/kd@de ds
fy,

DENSE/SEMI DENSE ASPHALTIC CONCRETE


?kuh@v/kZ ?kuh vLQkYV dahV

d lrg laokjus dk dk;Z vkSj vLRkj@vklatd ijr dks izFkd


ekik tk;sxkA
(b) The rates are worked out on the basis of binder content of [k ;g njsa dqy Hkkj dk 6@5-5 izfr'kr ysih feykcs dks vk/kkj eku
6%/5.5% of the total mix by weight. Any addition/
dj cuk;h xbZ gSaA okLRko esa iz;qDr ysih feykos dh fdlh Hkh
deduction in the actual binder content used, the rates shall
?kV@ c<+ dk lek;kstu] vuqlwph dh en 20073 ds varxZr
be adjusted as per SI item 20073.
gksxkA
(a) Preparation of surface and primming/tack coat shall be
measured separately.

447

SECTION 20B

SECTION 20BROAD WORK


[k.M 20ch&lM+d dk;Z
DENSE/SEMI DENSE ASPHALTIC CONCRETE
?kuh@v/kZ ?kuh vLQkYV dhV
PER 10
METRES

SQUARE

20069 Bituminous premix


asphaltic dense concrete
40mm consolidated
thickness with 6%
binder content by weight
of total mix, rolled and
compacted to required
camber and gradient

complete
20070 Ditto,
but
25mm
consolidated thickness

Ditto
20071 Ditto, as per item 20069,
but with 5.5% binder
content as in semi-dense
asphaltic concrete
20072 Ditto, as per SI Item
20070 but with 5.5%
binder content as in
semi-dense asphaltic

concrete

Except
binder

Binder content

ysih feJ.k

izfr 10 oxZ ehVj

ysih feJ.k

Paving bitumen
any penetration

Cut back
bitumen

psiw Mkej fdlh


izos'k dk

uenk Mkej

Rs.

Rs.

2539.30

Rs.
706.30

1680.00

534.50

2361.40

681.50

1533.40

483.20

20069 iw o Z fefJr rkjdks y h l?ku


vLQkYVhd dahV] Bksl eksVkbZ
40 feeh lkFk esa dqy feJ.k otu
dk 6 izfr'kr ysih] jksyj pykdj
<ky] mHkkj Bhd djrs gq;s Bksl
njslh laiwfrZ

20070 mi;qZDr] fdUrq Bksl eksVkbZ 25


feeh mi;qZDr
20071 mi;qZDr] tSlk en 20069 esa gS]
fdUrq 5-5 izfr'kr ysih feJ.k ds
lkFk tSlk fd v/kZ l?ku vLQkYVhd
dahV esa gksrk gS
20072 mi;qZDr] tSlk en 20070 esa gS]
fdUrq 5-5 izfr'kr ysih feJ.k ds
lkFk TkSlk fd v/kZ l?ku vLQkYVhd
dahV esa gksrk gS

PER KILOGRAM

izfr fdyks xzke

20073 Add/Deduct to SI items


20069 to 20072 for each

extra kg of binder used

20073 tksM@
as+ ?kVk;sa en la[;k 20069 ls
20072 es ls izfr fdxzk- iz;qDr
ysih ds fy,

46.90

CONCRETE ROAD, RUNWAY AND HARD-STANDING (FLEXURAL CONCRETE ONLY)


dahV lM+dsa] gokbZ if;ka vkSj dBksj Q'kZ CkUnh dsoy ypdnkj dahV

d lrg laokjus ds dk;Z dks izFkd ekik tk;sxkA


(b) Finishes to concrete surface by belting or brooming shall [k dahV dh lrg dks ioscn
a h ;k dwph ls laokjus ds dk;Z dks en
be measured under Item No. 20086 or 20087
20086 ;k 20087 ds vUrxZr ekik tk;sxkA
(c) The rales are applicable for flexural concrete only.
x ;g njsa dsoy ypdnkj dahV ij ykxw gSaA
?k vU; izdkj dh dahV fcNkou ds fy,] [kaM&13 Q'kZ dk;Z ns[ksAa
(d) For other type of concrete pavements, refer to
(a) Surface preparation shall be measured separately.

Section13 Flooring.
(e) The rates include for
(i) Use and waste of side form for laying pavement
concrete/hard-standing in bays between joints &
Contraction expansion joint/or between the two
contraction joints for thickness of pavement upto and
including 25 cm.

M nu njksa esa budk lekos'k gS%


(i) bu njksa esa [kaM+ksa esa vkLRkj.k dahV@iDds [kaMts fcNkus
ds fy;s] tksM+ksa o ladqpu izlkj tksMksa ds chp@;k nks
ladqpu tksMksa ds chp vkLrj.k lfgr 25 lseh rd eksVkbZ
ykus ds fy;ss ik'oZ cukus ds dk;Z o co 'kkfey gSaA

448

SECTION 20B

SECTION 20BROAD WORK


[k.M 20ch&lM+d dk;Z
CONCRETE ROAD, RUNWAY AND HARD-STANDING (FLEXURAL CONCRETE ONLY)
dahV lM+dsa] gokbZ if;ksa vkSj dBksj Q'kZ CkUnh dsoy eqyk;e dahV
(ii) For slab of thickness more than 25 cm, use and
waste of side forms, shall be paid extra as per
Section 7.
(iii) Provision and stipulation as specified except
specified here-in-after to give specified flexural
strength.
(iv) Cost of test to be carried out as specified to
establish quality control.
(v) Pavement more than 25cm thickness shall be
laid in more than one layer. Each layer shall not
be more than 25cm.
(f) The rates do not include for
(i) The construction, dummy (contraction) and
expanion joints.
(ii) Bull nosing of joints if ordered shall be separately
paid.
(g) No deduction shall be made in computing concrete
quantity for construction and dummy joints
(Contraction joints). However deduction shall be
made for expansion joints.
PER CUBIC METRE
20074 Cement concrete work in pavement/
hard-standing of flexural strength 40
kg/per square centimetre in field using
400 kg of cement per cubic metre,

thickness of concrete 25 cm or less

20075 Dittobut thickness more than 25 cm

M&L

ii 25 lseh ls vf/kd eksVh iVV~h ds ik'oZ cukbZ ds dk;Z o


co dk [kaM 7 ds vuqlkj vfrfjDr Hkqxrku gksxkA
iii fufnZ"Vkuqlkj okLrfod yphyh 'kfDr nsus ds fy,] fufnZ"Vr
vxys vk/kkj ds vykok] O;oLFkk rFkk vuqcanA
iv fufnZ"V xq.ko+k xq.kDrk LFkkiu ds fy,] tkap djus esa vkbZ
ykxrA
v 25 lseh ls vf/kd dh eksVkbZ dh ijr ,d ls vf/kd ijrksa
esa fCkNkbZ tk;sxhA izR;sd ijr 25 lseh ls vf/kd dh ugha
gksxhA
p bu njksa esa budk lekos'k ugh gS%
(i) ladqpu vkd`fr ladqpu rFkk izlkj tksM+A
(ii) tksM+ksa ds ik'oZ xksy djus dh vkKk gks rks mldk izFkd
Hkqxrku gksxkA
N fuekZ.k o udyh tksM+ ladqpu dks feykus ds fy, dahV
{kerk ds fy, dVkSrh ugha gksxhA fQj Hkh izlkj tksMk+ as dh dVkSrh
dh tk;sxhA

Labour
only

lk- o Je dsoy Je
Rs.
2413.30

Rs.

izfr ?ku ehVj


20074 iVfj;ks@
a iDds LFkkbZ [kMatksa esa fcNkou] yphyh
'kfDr dh 40 fd xzk@izfr ?keh( LFky esa 400
fd xzk lhesVa izfr ?ku ehVj iz;ksx djrs gq;s
25 lSeh ;k de dahV lfgr
20075 mi;qZDr] fdUrq eksVkbZ 25 lseh ls vf/kd

PER KILOGRAM
20076 Add/Deduct to item 20074 & 20075
if Extra/less/kg of cement used for

cubic metre

11.40

izfr fdyksxzke
20076 tksM+sa@?kVk;sa] en 20074 o 20075 es a
;fn vf/kd@de fdxzk lhesaV izfr ?ku
ehVj ds fy;s iz;ksx fd;k x;k gS

JOINTS IN PAVEMENT AND HARD STANDING


foNkou vkSj dBksj fcNkou esa tksM+s
(a) The rates include for any extra form work if required to
form joints.
(b) No deduction shall be made from concrete, for contraction
(Dummy) and construction joints. Deduction, shall, however
be made for expansion joints.

d njksa esa tksM cukus esa ;fn vfrfjDr Qjescanh visf{kr gS] rks og
Hkh 'kkfey gSA
[k dahV esa ls ladqpu iqrys vkSj ladqpu tksM+ksa ds fy, dVkSrh
ugha gksxhA fQj Hkh izlkj tksM+ksa ds fy, dVkSrh gksxhA

449

SECTION 20B

SECTION 20BROAD WORK


[k.M 20ch&lM+d dk;Z
JOINTS IN PAVEMENT AND HARD STANDING
foNkou vkSj dBksj fcNkou esa tksM+s & tkjh
PER 10 RUNNING METRE

Thickness of concrete slab in mm

izfr 10 ehVj

dahV ifO;k dh eksVkbZ feeh esa


20077Forming 12mm thick
Expansion joints filled with
pre-formed bituminous filler
and top 30mm primed and
sealed with sealing com
pound, Grade A
20078Forming 20mm thick ex
pansion joints ditto
20079Forming 12 mm thick expansion joints filled with
pre-formed bituminous filler
and top 30mm primed and
sealed
with
sealing

compound, Grade B
20080Forming 20mm thick Ex
pansion joint ditto

100

150

200

250

Rs.

Rs.

Rs.

Rs.

663.70

928.00

1212.30

1476.70

828.00

1121.80

1415.50

1709.30

678.20

924.00

1226.60

1490.90

835.90

1129.70

1443.10

1736.10

20081 Add to items 20077 to 20080


if provided with 20 mm dia
mild steel dowel bars 50cm
long (25cm in each slab)
with ferrules, spaced at 300
mm centres, including boring
form work and preformed

filler for dowels

PER 10 RUNNING METRE


20082 Forming Contraction (Dummy)
joints 65mm deep x 10mm wide,

filled with sealing compound


20083 Add to or deduct from item
20082 for every 5 mm depth of joint

over or under
20084 Forming Construction joint
30mm deep x 10mm wide filled

with sealing compound


20085 Add to or deduct from item
20084 for every 3 mm depth of joint

over or under

175.80

z ^,* Js.kh
Rs.

20079 12 feeh eksVs izlkj tksMk+ as dks


iwoZ fefJr rkjdksyh iwjd vkSj
ij 30 feeh vLrj rFkk ch
Js.kh ds iw j d feJ.k ls
Qjescn
a h
20080 20 feeh eksVs izlkj tksM+
cukuk] mi;qZDr
20081
20081tksMsa+] en 20077 ls 20080 esa]
;fn uje yksgs dh 20 feeh
O;kl dh QUuh lfj;k 50 lseh
yEch 25 lseh izfr ifO;k tksM
pwM+h ds lkFk] 300 feeh vUrj
ij dsfUnzrq Qjescna h esa Nsn djus
rFkk dUuh ds lkFk

Rs.

Grade 'A'

20077 12 feeh eksVs izlkj tksM+ksa dh


iwoZ fefJr rkjdksyh iwjd vkSj
30 feeh ijh vLrj yxkdj
rFkk , Js.kh ds iwjd feJ.k ls
Qjescanh
20078 20 feeh eksVs izlkj tksM+ cukuk
mi;qZDr

Grade 'B'
^ch* Js.kh
Rs.

izfr 10 ehVj
20082 ladqpu iqrys tksMk+ as dk izk#i.k] 65
feeh xgjs x 10 feeh pkSM+s iwjd feJ.k
ls iwfjr
20083 en 20082 esa] tksMsa+ ;k esa ls ?kVk;s]
izR;sd tksM dh 5 feeh vf/kd ;k de
xgjkbZ ij

474.30

496.90

36.80

38.50

238.20

248.80

20084 fuekZ.k tksM dk izk#i.k] 30 feeh xgjs x


10 feeh pkSM+s iwjd feJ.k ls iwfjr

23.80

24.90

20085 en 20084 esa tksMas+ ;k esa ls ?kVk;s] tksM


dh izR;sd 3 feeh xgjkbZ ij

450

SECTION 20B

SECTION 20BROAD WORK


[k.M 20ch&lM+d dk;Z
FINISHES TO CONCRETE ROADS, PAVINGS, ETC.
dahV dh lM+d] fCkNkou vkfn dh laiwfrZ
Rs.

izfr 10 oxZ ehVj

20086 Finishing surface of concrete roads,

pavements, by belting

22.40

20087 Ditto, but by brooming

44.70

20086 isOnkjh }kj dhV dh lM+dks]a fcNkouksa dh lrg


dh laiwfkZ
20087 mi;qZDr] fdUrq cqgkjh }kjk

PER 10 SQUARE METRE

PER 10 RUNNING METRES

izfr 10 ehVj

20088 Rounding edges of concrete not


exceeding 10mm radius with an

edging tool

20088 dahV ds 10 feeh vuf/kd O;kl ds dahV ds


fdukjksa dh fdukjscn
a h midj.k ls xksy djuk

MATERIALS (Supply only)


lkexzh dsoy vkiwfRRkZ
PRE-FORMED FILLER
iwoZ fefJr iwjd
Rs.

izfr oxZ ehVj

20089 12mm thick pre-formed filler for

expansion joints

528.70

20089 izlkj tksM+ksa ds fy, 12 feeh eksVk


iwoZ fefJr iwjd

20090 18/20 mm thickditto

587.50

20091 25mm thickditto

646.20

PER SQUARE METRE

20090 mi;qZDr] fdUrq 18@20 feeh eksVk


20091 mi;qDr] fdUrq 25 feeh eksVk

PER KILOGRAM

iz f r fdyks x z k e

20092 Paving Bitumen any penetration in

cluding container
20093 Cut back bitumen any type and

grade

38.20
39.40

20092 fdlh Hkh izos'k dk vLrjh rkjdksy


Hkktu fMCcs lfgr
20093 fdlh fdLe rFkk Js.kh dk uiFkk
rkjdksy

JOINTS SEALING COMPOUND MATERIAL


tksM+ksa dks cUn djus okyh feJ.k lkexzh
PER KILOGRAM OF
MATERIAL
20094 Joint Sealing Compound Grade A

(Normal) in 25/30 Kg.


20095 dittoGrade B (Jet fuel resistant)

in 25/30 Kg.

lkexzh dk izfr fdyksxzke


Rs.

52.90
56.40

20094 oxZ , dk lkekU;] 25@30 fexzk esa


tksM+ksa dks can djus okyk ?kksy
20095 oxZ ch vfXujks/ku mi;qZDRk

451

SECTION 20B

SECTION 20BROAD WORK


[k.M 20ch&lM+d dk;Z
JOINTS SEALING COMPOUND MATERIAL
tksM+ksa dks cUn djus okyh feJ.k lkexzh
PER LITRE

Rs.

20096 Primer for Grade A sealing

compound
20097 dittofor Grade Bditto

61.10
64.60

iz f r yhVj
20096 , oxZ ca/ku ?kksy ds fy;s izkbej

20097 ch oxZ&ds fy;s mi;qZDRk

izfr 50 fdyksxzke

PER 50 KILOGRAM
20098 Portland/High grade (high strength)

cement

270.20

20098 iksVZySaM@mPp oxZ mPp 'kfDr


lhesaV

452

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
SPECIAL CONDITIONS
fo'ks"k 'krsZa
21.1 Measurements
(a)
Measurements of all work, except hidden work,
shall be taken before commencement of demolition
or dismantling. No allowance shall be made for
any increase in bulk.
(b)
In respect of deductions for voids, openings, etc.
the method of measurements shall be as described
for new work in relevant Sections.

21-1 eki
d lHkh dk;ksZ dh] eki flok; Nqis dk;kZsa ds] rksM+us ;k m[kkM+us
ds dk;Z ds izkjEHk gksus ls igys yh tk;sxhA cM+h ek=k esa gqbZ
fdlh Hkh c<+ksrjh ds fy, dksbZ NwV ugha nh tk;sxhA
[k f>fj;ksa o [kqys LFkkuksa vkfn ds fy, dVkSrh djus dh fof/k ogh
gksxh tks lacfU/kr [k.Mksa esa uohu dk;Z ds fy, of.kZr gSA

21.2 Rates
21.2.1 The rates for demolition and dismantling include:
(a)
Breaking up and taking up or down in case of
demolition, as defined.

21-2 njs a
21-2-1 rksM+us vkSj m[kkM+us dh njksa esa fuEu lekfgr gSa%
d rksM+us esa] rksM+uk] mBkuk ;k fxjkuk vkrk gS] tSlk fd
fufnZ"Vr gSA
[k m[kkM+us esa /;kuiwoZd mBkuk ;k fxjkuk rFkk fcuk gkfu
igqapk;s gVkuk] tSlk fd fufnZ"Vr gSA
x mi;ksxh lkexzh dks vuqi;ksxh lkexzh ls vyx djuk
eyos o dwM+s djdV dk izHkkjh vfHk;ark dh vkKkuqlkj
100 eh dh vuf/kd nwjh ij fuiVkjk djukA mi;ksxh
oLrqvksa dk 100 eh ds vUnj pk yxkuk dkSu&lh oLrq
mi;ksxh gS vkSj dkSu lh vuqi;ksxh] bl fo"k; esa izHkkjh
vfHk;ark dk fu.kZ; vfUre ,oa ck/; gksxkA
?k m[kkM+us ds dk;Z esa] dhyksa] dkaVksa o ispksa dks yDdM+ esa
ls fudkyukA
M- NksVh phtsa tSls [kwafV;k] f'kdats] yxkoh dkoys vkfn
izR;sd 3 fdxzk ls vuf/kd dks tks rksM+us@m[kkM+us essa
fudys gksa mudks mBkuk] lkQ djuk o NkaVuk vkfnA
p ftu Hkkxksa dks fxjkus dh vko';drk ugha gS ;k iM+kl
s dh
laifk dh lqj{kk dk vLFkkbZ izcU/k djuk rFkk izHkkjh
vfHk;Urk dh bPNkuqlkj vko';d vLFkkbZ ?ksjscanh ;k
foHkktuksa dh O;oLFkk djukA
N tu laifk dh iw.kZ lqj{kk ds fy, t:jh iwoZ mik; djuk
rFkk /kwy dh ijs'kkuh dk izcU/k djukA
t izHkkjh vfHk;ark ds funs'Z kkuqlkj fdlh lsok dk vLFkkbZ ;k
LFkkbZ foPNsnu djuk] fdlh pht dks Bhd djus ds dk;Z
dks izFkd ekik tk;sxkA
21-2-2 RkksMu+ s vkSj m[kkM+us ds dk;Z dh njksa esa dVkSrh ugha gksxh
;fn dqN ;k lkjh mi;qDr@vuqi;qDr lkexzh dks dk;ZLFky
;k dk;ZLFky ds ikl gh ps yxkus@QSykus rFkk lery
djus dh vkKk nh tkrh gSA
21-2-3 vfrfjDr nwjh ds fy, vfrfjDr Hkqxrku ugha gksxk tc
nqxZ vfHk;Urk dh vkKk ls Bsdsnkj vius iz;ksx ds fy,
vuqi;ksxh lkexzh ys tkrk gS vkSj u gh mldh fdlh
dher dh dVkSrh gksxhA

(b)

Carefully taking up or down and removing without


damage, in case of dismantling, as defined.

(c)

Separation of serviceable materials from the


unserviceable; stacking the serviceable materials
within 100m and disposal of unserviceable material,
debris and rubbish to a distance n exc 100m as
directed by the EIC. The decision of the EIC as to
which materials are serviceable or otherwise shall
be final and binding.
Removal of nails, spikes and screws from timber in
case of dismantling.

(d)
(e)

(f)

(g)

(h)

Picking, cleaning, sorting out etc. small articles


such as wall ties, clamps, holding down bolts etc.
not exceeding 3 kg each, which come out as a result
of demolition/ dismantling.
Temporary shoring for the safety of portions not
required to be pulled down, or of adjoining property,
and providing temporary enclosures or partitions,
where considered necessary by EIC.
Taking all necessary precautions for the protection
of the public property and to keep down dust
nuisance etc.
Any necessary disconnection of services, whether
temporary or permanent as directed by EIC; any
making good shall be measured separately.

21.2.2 No deduction in rates shall be made for demolition


and dismantling if some or all of the serviceable/
unserviceable materials are ordered to be stacked/
spread and levelled at or near the site of work.
21.2.3 No payments shall be made for any extra lead, when
with the approval of the G.E., the unserviceable
materials are removed by the Contractor for his own
use, nor will any deduction be made for any value,
they may have.

453

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
BRICKWORK AND MASONRY
bZV dk;Z vkSj iRFkj fpukbZ
(a)
(b)

d lHkh eqM
a js ]s a rk[ks]a dkjfu'ksa rFkk nwljs foLrkjksa dks nhokj dh eki
esa feyk fy;k tk;sxk
The rates include taking down walls, etc, with plaster [k njsa iyLrj lfgr nhokjksa vkfn dks fxjkus ds fy, gSa fdUrq eki
but the measurements will be exclusive of plaster
iyLrj dh eksVkbZ dks NksM+dj yh tk;sxhA foNkou o Q'kkasZ
thickness. In case of pavings and floors the rates include
ds ekeys esa bu njksa esa foNkou ijr dks m[kkM+uk 'kkfey gSA
for removal of bedding layer.
All copings, corbels, cornices and other projections shall
be included with the wall measurements.

(c)

Honeycomb brickwork and hollow concrete blocks


shall be measured solid.

x e/kqdks"kh; bZV dk;Z rFkk [kks[kyh dahV dks Bksl ekik tk;sxkA

(d)

Items 21001 to 21005 apply to brickwork and stone


masonry other than in roofs and pavings/floors.

?k en 21001 ls 21005] Nr o fcNkou@Q'kksaZ ds dk;Z ds


vykok] bZV dk;Z o iRFkj dh fpukbZ ij ykxw gksrh gSaA

PER CUBIC METRE

21001 Brickwork or stone/


boulder masonry, laid dry

21002 Ditto, but built in mud

mortar
21003 Brickwork or stone/
boulder masonry, built in
lime mortar
including
all quoins, arches, pillars,
etc, but excluding ashlar
facings,
dressed
stonework and precast

concrete articles
21004 All as above but built in
cement mortar or cement

lime mortar
21005 Add to items 21003 &
21004 for ashlar facings,
dressed
stonework,
precast concrete articles
and precast concrete

block walling

Demolition

Add for portions ordered


to be dismantled

rksMu+ k

m[kkM+us okys Hkkxksa ds fy, tksMas+

Rs.

Rs.

216.20

27.40

izfr ?ku ehVj

21001 bZV dk;Z ;k iRFkj@f'kyk[kaM


fpukbZ] lw[kk fcNkou
21002 mi;qDZ r] fdUrq feh xkjs esa fufeZr

251.80

27.40

302.00

37.10

417.80

31.80

21003 bZV dk;Z ;k iRFkj@f'kyk[kaM dh


fpukbZ lHkh QfUu;ks]a esgjkoks]a [kEHkksa
vkfn lfgr pwuk elkys esa fufeZr
fdUrq vlyjh eq[kkSVs laokjs gq,
iRFkj dk dk;Z ,oa iwoZ fojfpr
dahV dh oLrqvksa dks NksMd
+ j

76.20

21004 lc mij tSlk fdUrq] lhesVa elkys


;k lhes a V pw u k elkys es a
fufeZr

8.70

21005 tksM+sa en 21003 o 21004 esa]


vLyj] eq[kkSVs] laokjs gq, iRFkj
dk dk;Z] iwoZfojfpr dahV dh
oLrqvksa o dahV [kaMdksa dh
nhokjxhjh ds fy,

454

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
JACK ARCHES AND REINFORCED BRICKWORK
Hkkjh esgjkosa vkSj izofyr bZaV dk;Z
TABLE CONTD...
PER CUBIC METRE

Rs.

Rs.

izfr ?ku ehVj

21006 Brick jack arches in lime mortar

21007 Ditto in cement mortar or cement lime

mortar
21008 Reinforced brickwork in suspended
slabs, beams, lintels etc. in cement
mortar
or
cement
concrete
(reinforcement cut as required to

facilitate demolition)

378.50

75.90

494.20

113.80

441.80

187.60

21006 bZaVksa dh pwuk elkys esa cuh Hkkjh esgjkosa


21007 mi;qZDr fdUrq lhesaV elkys ;k lhesaV pwuk

elkys esa
21008 yafcr if;ks]a dfM+;ks]a MkVksa vkfn esa izofyr
bZVa dk;Z lhesaV elkys ;k lhesaV dahV esa
rksM+us esa lqfo/kk ds fy;s vko';drkuqlkj

izoyu dh dVkbZ djuk

STONE AND BRICK PAVINGS/FLOORS


iRFkj vkSj bZV fcNkou@Q'kZ canh
PER TEN SQUARE
METRE

Demolition

Dismantling

rksMu+ k

m[kkM+uk

Laid dry
or laid
dry and
pointed

lw[kh fcNh
;k lw[kh
fcNh o
Vhi dh
gqbZ
21009 Stone slabs and tiles of any
description or thickness in

floors, aprons etc.


21010 Stone sett paving of any

description or thickness
21011 Bricks (laid flat or on edge) or
brick tiles in floors, channels,
kerbs, aprons, etc. (each layer)

Rs.
138.60
366.20

304.20

izfr 10 oxZ ehVj

Laid,
Laid dry Laid,
bedded or laid bedded
and
dry and
and
pointed pointed pointed
in any
in any
mortar
mortar

likV]
fcNh o
fdlh
elkys
ls Vhi
dh gqbZ

lw[kh fcNh likV]


;k lw[kh
fcNh
fcNh o o fdlh
Vhi dh elkys ls
gqbZ
Vhi dh
gqbZ
21009 Q'kka]sZ vkoj.kksa vkfn esa yxh fdlh
Rs.
Rs.
Rs.
Hkh vkdkj ;k eksVkbZ dh iRFkj
dh if;ka o Vkbysa
186.70
157.50 210.70
21010 fdlh Hkh vkdkj ;k eksVkbZ ds
474.00
405.50 575.50
iRFkj ds pkSdksa dk fcNkou
21011 Q'kkZ]sa ukfy;ks]a iRFkj ds fdukjks]a
vkoj.kksa vkfn izR;sd ijr esa
yxh bZVa as likV ;k [kM+h ;k bZVa
343.50
322.70 380.70
dh Vkbysa

455

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
CLEANING BRICKS, STONES, ETC.
bZVksa iRFkjksa vkfn dks lkQ djuk
Items 21012 to 21014 shall be paid in addition to
demolition/dismantling where cleaning and stacking
bricks and stones are ordered.

izfr 1000 la[;k lkQ


bZV dh

Work built in

PER 1000 NOS OF


CLEANED BRICKS

21012 Removing mortar from and


cleaning bricks, stacking for
measurement including all
extra handling and removal
and disposing off rubbish

rksM+uk@m[kkM+us ds dk;Z esas tgka bZVksa vkSj iRFkjksa dks lkQ djus
o pos yxkus dh vkKk nh xbZ gks] ogka en 21012 ls 21014 esa
vfrfjDr Hkqxrku gksxkA

dk;Z vra% fufeZr


Mud
mortar

Lime
mortar

Cement or
cement lime
mortar

feos xkjk

pwuk elkyk

lhesaV ;k
lhesaV pwuk
elkyk

Rs.

Rs.

Rs.

305.80

516.30

774.40

137.40

226.80

331.00

396.60

21014 mi;qZDr] vlyj eq[kkSVs] laokjs


iRFkj ds dk;Z] fcNkou iRFkj ifO;k
rFkk iwoZ fojfpr dhV [kaM o oLrq;]as

mi;qZDr

PER CUBIC METRE OF


CLEANED STONE
21013 Removing mortar from and
cleaning stones, obtained
from masonry of any
description (except ashlar
facings and dressed stone
work) and stone setts from
pavings;
stacking
for
measurement including all
extra handling and removal
and disposing off rubbish
21014 Ditto, ashlar facings, dressed
stone work, stone slabs or tiles
from paving and precast
concrete blocks and articles,

ditto

161.20

266.50

21012 bVksa ij ls elkyk NwM+kuk] lkQ


djuk eki ds fy, pV~Vksa esa yxkuk
o lHkh vfrfjDr laHkky lfgr
rFkk eyos dks gVkuk o fuoVkjk

djuk
lkQ iRFkj vkfn dk izfr
?ku ehVj
21013 fdlh izdkj dh fpukbZ ls izkIr
iRFkj o fcNkou esa yxs iRFkjksa dks
vlyj eq[kksVs ,oa lokjs iRFkj ds
dk;Z dks NksMd
+ j gVkuk o lkQ
djukA eki ds fy, pV~Vksa esa yxkuk]
lHkh laHkky dk;Z lfgr rFkk eyos
dks gVkuk o fuoVkjk djuk

CONCRETE IN SITU
izfrLFkkiu esa dahV
(a) The thickness of terrazzo tiles of any description and
similar finish, shall be included in the measurement unless
removal of such finish is indicated as a separate operation.
In case of patch work in floors or paving (each patch n exc
0.5 sq.m. the rates under items 21015 and 21016 shall be
increased by 33.34 percent. This allowance shall also
include for trimming bottom and sides of cut surfaces.
(b) Items 21015 and 21016 apply to cutting through full
thick- ness of floors and pavings. Where a part thickness
only of a concrete floor is cut, payments shall be made
under surface excavation vide items 03001 and 03002.
(c) In the case of patches n exc 0.5 sq.m. each, rates for cutting
shall be increased by 33.34 percent. This allowance shall
also include for trimming bottom and sides of cut surfaces

d fdlh Hkh vkdkj o leku laifw rZ dh rjStks] Vkbyksa dh eksVkbZ dks


eki esa 'kkfey fd;k tk;sxk tc rd fd ,slh iwfrZ;ksa dks ,d
izFkd dk;Z ds :i esa u n'kkZ;k x;k gksA Q'kZ ;k fcNkou ds isou
dk;Z esa izfr isou 0-5 oeh ls vuf/kd en 21015 o 21016 dh
njksa dks 33-34% c<k+;k tk;sxkA ;g vfrfjDr ry fdukjh o
dVh lrgksa dh cxyksa dks Hkh lekfgr djsxkA
[k en 21015 o 21016 dh njsa Q'kksZa o fcNkouksa dks iwjh eksVkbZ esa dkVus
ij ykxw gksrh gSAa tgka Q'kZ dh dah+ V dk dsoy dqN Hkkx dkVk x;k
gks rks Hkqxrku lrg dh [kqnkbZ ds varxZr en 03001 o 03002esa gksxkA
x 0-5 oxZ ehVj vuf/kd ds isou dh dVkbZ ds fy, dVkbZ dh
njksa esa 33-34% dh c<+ksrjh dh tk;sxhA ;g vfrfjDr ry
fdukjh o dVh lrgksa dh cxyksa dks Hkh lekfgr djsxkA

456

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
CONCRETE IN SITUContd...
izfrLFkkiu esa dahV tkjh
Demolition

PER CUBIC METRE

izfr ?ku ehVj

rksMu+ k
Lime
concrete

Cement concrete
(unreinforced)

pwuk elkyk

lhesaV dhV
vizofyr

21015 Concrete in ground floors and


pavings n exc 15 cm thickness
(below or above ground level)

Rs.

Rs.

281.20

417.80

21016 Ditto exc 15 cm thickness but

above ground floors

318.30

648.90

261.30

494.00

21017 Concrete of any description and


in any position not otherwise

specifically provided for


21018 Roofs, floors (other than ground
floors), beams, staircases, landing,
chajjas and similar suspended

work

21019 Add to items 21015 to 21018 if cement


concrete is reinforced (reinforcement cut

as required to facilitate demolition)


21019A Add to items21017 and 21018 for portions

ordered to be dismantled

797.90
Rs.
76.40
-

21015 Q'kkasZ o fcNkouksa esa 15 lseh vuf/kd


eksVh dahV Hkwfery ls uhps ;k

ij
21016 mi;qZDr] eksVkbZ 15 lseh ls vf/kd

fdUrq Hkwfe ds ij
21017 fdlh Hkh rjg dh o fdlh Hkh voLFkk
dh dahV tc rd fo'ks"k :i ls

blds fy, izko/kku u gks


21018 Nrsa] rYys Hkwfe ry dks NksM+dj
dfM;k] lhf<+;ka] pcwrjs] NTts o
leku yafcr dk;Z

21019 en 21015 ls 21018 esa tksMas ;fn lhesVa dahV izofyr


gS izoyu dh rqMk+ bZ dh lqfo/kk ds fy, visf{kr dVkbZ

21019 A en 21017 o 21018 esa mu Hkkxksa ds fy, tksMs+a ftUgsa

m[kkM+us dh vkKk nh xbZ gS

WOOD WORK AND JOINERY


ydM+h dk;Z vkSj la;kstu
(a) For taking down complete roof trusses, see Section
7-Wood work (Carpenter's work).
(b) For taking down complete joinery, see Section 8- Joinery.
(c) The rates given below apply to dismantling of both soft
and hard wood work and joinery and also allow for
removal and stacking separately of all straps, bolts, nuts
etc, where fixed.

d Nr ds lai.w kZ vk/kkjksa dks fxjkus ds fy, ns[kas [k.M&7 ydM+h


ds dk;Z c<+bZ dk dkeA
[k laiw.kZ la;kstuksa dks fxjkus ds fy, ns[ksa [k.M&8 la;kstuA
x ;g njsa] uje o l[r nksuksa izdkj dh ydM+h ds dk;Z o
la;kstu ij ykxw gksrh gSa vkSj lHkh if;ka dkoys o f<cfj;ka
vkfn tgka yxs gSa] mUgsa fudkyus rFkk izFkd <sj yxkus dh
vuqefr Hkh nsrh gSaA

457

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
WOOD WORK AND JOINERYContd...

ydM+h dk;Z vkSj la;kstu tkjh


PER CUBIC METRE

21020 Dismantling timber scantlings 40


sq. cm and over in section, in any

position

Unframed
work

Framed work

pkS[kVs ds dk;Z

fcuk pkS[kVs ds
dk;Z
Rs.

Rs.

285.20

360.90

3.60

6.40

PER SQUARE METRE


21022 Dismantling boarding, any
description, fixed in any position

with nails

21023 Ditto, if fixed with screws


PER SQUARE METRE

21024 Battens for tiles, shingles etc, of

any size including tilting fillets

21025 Trellis work (Jafri), including


taking as under of battens in
trellis (posts and rails measured

separately)

21020 ydM+h dh 40 olseh o vf/kd dh dVkbZ


dh NksVh phtksa dks m[kkM+uk
iz f r ehVj

PER RUNNING METRE


21021 Ditto in fillets, rails, posts, rafters,
purlins, etc. under 40 sq. cm in

section

izfr ?ku ehVj]

21021 mi;qZDRk] ifk;ksa] taxyksa] [kaHkksa] /kjfu;ksa]


'kgrhjksa vkfn esa] 40 oxZ lseh dkV esa
izfr oxZ ehVj
21022 fdlh fdLe fdlh :i esa dhyksa ls yxh
r[rs canh dks m[kkM+uk

Rs.
15.90

21023 mi;qZDr] ;fn ispksa ls yxs gksa

18.90

vUrjh;

Spaced
Nexc 15 cm

Exc 15 cm

15 lseh ls
vuf/kd

15 lseh ls
vf/kd

Rs.
12.00

Rs.
5.20

One way

Two way

,d iaFkh

f}iaFkh

Rs.

Rs.

16.30

80.90

izfr oxZ ehVj

21024 fdlh vkdkj dh] rkf[;ka ;k r[rs yxkus


dh iVfj;ka] frjNh [kwafV;ksa lfgr

21025 tkyh dke tkQjh m[kkM+us lfgr tSlk


fd tkyh esa r[rs pkS[kVs o taxys izFkd
ekih tk;saxh

STEEL AND IRON WORK


(a)

(b)

(c)
(d)

bLikr vkSj yksgs dk dk;Z


The rates include unbolting, dismantling framed work into d bu njksa esa dkoys [kksyuk] pkS[kVs okys dke dks nks ;k vf/kd
two or more portable parts and marking members for re-erection
ys tkus ;ksX; Hkkxksa esa [kksyuk rFkk ;fn ladsr nksokjk yxkus
if so indicated. If framed work is indicated to be dismantled
dk gks rks Hkkxksa dks vafdr djukA ;fn pkS[kVksa ds dke dks
into primary members, payments shall be made in addition as
izkjfEHkd vo;o ds :i esa ykus dk vkns'k fn;k tkrk gS rks
provided here under.
bu njksa ds izko/kku ls vf/kd dk Hkqxrku gksxkA
In dismantling framed steel gates, doors, and the like, the [k pkS[kVs esa yksgs ds QkVd] njokts o leku oLrqvksa] dks
weight of any covering material or filling such as steel
m[kkM+us eas fdlh vkoj.k lkexzh Hkjko tSls yksgs dh pknj]
sheets, expanded metal, etc. shall be added to the weight of
foLr`r /kkrq vkfn ds Hkkj dks eq[; oLrq ds Hkkj esa tksM+ fn;k
the main article, if such covering is not taken out separately.
tk;sxk ;fn ,sls vkoj.kksa dks izFkd :i ls ugha fy;k tkrkA
The weight of structural steelwork shall be computed as x yksgs ds dke dh <akpkxr Hkkj [k.M 10&yksgs vkSj bLikr dk;Z
given in Section 10Steel and Iron Work.
ds vUrxZr x.kuk dh tk;sxhA
The rates shall be for the salvaged steel.
?k ;g njsa fuLrkj yksgs ds fy, gksaxhA

458

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
STEEL AND IRON WORKContd...

bLikr vkSj yksgs dk dk;Z tkjh


PER QUINTAL

Rs.

21026 Separating, scraping and cleaning of


reinforcement (Demolition of concrete

measured separately)
21027 Dismantling cast iron work of any de
scription

436.90

21028 Dismantling wrought iron or mild steel


work of any description not otherwise

provided for
21029 Dismantling structural steel work including doors, gates but excluding framed

truss etc.

172.70

155.40

168.70

Span
foLrkj
N exc Exc 10m but Exc 15m but
10 m
n exc 15m n exc 22.5m

EACH

iz f r fDoa V y
21026 izoyu dks vyx djuk] [kqjpuk vkSj lkQ djuk
dah+ V dh rqMk+ bZ dks izFkd ekik tk;sxk
21027 fdlh Hkh izdkj ds <ys yksgs ds dke dks
fm[kkM+uk
21028 dkEVh yksgs ;k uje yksgs ds fdlh fdLe ds dke
ftldh vU;Fkk O;oLFkk ugha gS] dks m[kkM+uk
21029 <akpsxr yksgs ds dke] njokts] QkVd fdUrq
pkS[kVsnkj phtksa dks NksMd
+ j] dks m[kkM+uk

iz R ;s d
Exc 22.5m but
n exc 30m

vuf/kd
10 eh ls 15 eh ls vf/kd 22-5 eh ls vf/kd
s 10 eh vf/kd] o 15 eh o 22-5 eh ls
o 30 eh ls
ls vuf/kd
vuf/kd
vuf/kd
Rs.
21030 Dismantling framed

trusses

362.70

Rs.
787.80

Rs.
1542.00

Rs.
2378.80

PER QUINTAL
21031 Extra only if all
members are required
to be taken as under by

cutting rivets

Rs.
166.80

21030 pkS [ kVs n kj dS f p;ks a dks


m[kkM+uk
iz f r fDoa V y
21031 vfrfjDr] ;fn lHkh vo;oksa
dks fjfiV dhy dkVdj
vyx djuk gks dsoy rHkh

ROOF AND WALL COVERINGS, CEILINGS AND LININGS

Nr o nhokj vkoj.k] Hkhrjh Nr vkSj Hkhrjh vkoj.k


(a) All work shall be measured flat overall and not girthed.
(b) Measurements of ridges, hips, valleys and flashings shall
be taken in sq. m and paid for at the same rates as for roof
covering of similar materials.

d eki ifjiw.kZ likV yh tk;sxh ?kuRo esa ughaA


[k mBkoh] mHkjh gqbZ ladqfpr o pedhyh oLrqvksa dh eki oeh esa
yh tk;sxh rFkk budk Hkqxrku leku lkexzh ds Nr vkoj.k dh
njksa ds vuqlkj gksxkA

459

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
ROOF AND WALL COVERINGS, CEILINGS AND LININGSContd...
Nr o nhokj vkoj.k] Hkhrjh Nr vkSj vkoj.k tkjh
PER SQUARE METRE
21032 Plain or corrugated steel sheeting,
any gauge, thickness, including
Nainital or similar pattern roof

coverings

Demolition Dismantling

rksM+uk
Rs.

10.90
16.00

21035 Mangalore pattern roofing tiles

with ceiling tiles or slate roofing


21036 Add to items 21034 and 21035 for
portions bedded in lime or cement

mortar
21037 Stone slabs in roofs, suspended
floors, chajjas, landings, etc., any

thickness, jointed in any mortar


21038 Brick tiles or terracing tiles, single

layer on roofs

21039 Ditto, double layer

21040 Roof shingles (wood)


21041 Textile coverings including
frames (if any) and cover fillets
(measured flat and not girthed)

21042 Wall and ceiling boards (fibre,


pulp, insulation, etc.) or
insulation
boards/slabs/
blankets, any thickness, including

cover fillets

Rs.

8.30

21033 Asbestos cement (corrugated,


semicorrugated, etc.) sheets in roof

coverings
21034 Single layer Mangalore pattern or

similar tiles in roofing

31.00

3.70

izfr oxZ ehVj

m[kkM+uk

7.30
24.30

20.20

26.80

32.90

42.60

13.60

18.80

8.00

12.20

8.00

12.70

21032 likV ;k ygfj;k fdlh vkeku] eksVkbZ o yksgs


dh pknj dk vkoj.k] uSuhrkyh ;k leku
rjhds dk Nr vkoj.k
21033 Nr vkoj.k esa ,LoSLVl lhesVa ygfj;k] vFkZ
ygfj;k vkfn dh pknjsa
21034 Nr dk;Z esa ,dy ijrh eaxykSjh rjhds ds ;k
leku [kijsa
21035 eaxykSjh rjhds dh Nr dh [kijs lkFk esa Hkhrjh
Nr [kijsa ;k LysV iRFkj dh Nr iVkbZ
21036 tksMas+ en 21034 o 21035 esa mu Hkkxksa ds fy,
ftUgsa pwuk ;k lhesVa elkys esa fcNk;k x;k gS
21037 iRFkj dh ifV;k fdlh Hkh eksVkbZ dh fdlh Hkh
elkys ls Nrks]a yafcr Q'kkaZs NTtksa vkfn esa
21038 bZV Vkby ;k Nr Vkbyksa dh ,d ijr Nr ds
ij
21039 iwoksZDr] nqgjh ijr
21040 Nr ds r[rs ydM+h
21041 pkS[kVs lfgr ;fn dksbZ cqus diMs+ ds vkoj.k
rFkk vkoj.k fdukfj;ka likV ekih tk;saxh]
?kuRo esa ugha
21042 nhokj rFkk fupyh Nr ds r[rs js'ks] clk]
fctyhjks / kd vkfn ;k /kkjkjks / kd
r[rs@ifV;k@vkoj.k fdlh eksVkbZ ds] vkoj.k
fdukjh lfgr

460

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
ROOF AND WALL COVERINGS, CEILINGS AND LININGS Contd...
Nr o nhokj vkoj.k] Hkhrjh Nr vkSj vkoj.k tkjh
PER SQUARE METER

Demolition

izfr oxZ ehVj

rksMu+ k
21043

7.80

21043 fdlh Hkh eksVkbZ ds NIij p<+koksa o mHkkjksa


esa ca/kkbZ lfgr

3.90

21044 ,dgjh ;k nksgjh fdlh Hkh izdkj dh pVkbZ]


ckal] pkS[kVs ;k ckal lgkjs] vkoj.k fdukjh
;fn dksbZ] lfgr

Rs.

Thatching any thickness including

capping to ridges and hips

21044 Matting, single or double any type


including, bamboo framing or bamboo

supports, cover fillets, if any

izfr ?ku ehVj

PER CUBIC METRE


21045 Mud in roofs, any thickness,
including plastering and leeping
(whether full thickness removed or

only a part thereof)

21045 Nr esa fdlh eksVkbZ dh feV~Vh] iyLrj o


fyikbZ lfgr pkgs iwjh eksVkbZ ;k mldk
;k dsoy ,d Hkkx gVk;k gks

300.40
MISCELLANEOUS

fefJr
PER SQUARE METRE
21046 Demolition of reed, lathing, single
or double, including battens and
plaster or chicken wire lathing

21046 iVjh] ydM+h dh iafDr;ka ,dgjh ;k nksgjh


iVjh o iyLrj ;k irys rkj dh ca/kkbZ
lfgr rksM+uk

11.90

21047 Ditto, bamboo framing any type in


roof or walls including attached
whole bamboos or bamboo trellis

work
21048 Dismantling fencing wire mesh,

any type

PER SQUARE METRE

izfr oxZ ehVj

Rs.

21047 mi;qZDr] Nr ;k nhokjksa esa fdlh fdLe dh


ckal ca/kkbZ] iwjs ckal ;k ckal dh [kifPp;ksa
ds dk;Z lfgr

5.00
3.30

21048 fdlh fdLe dh rkj tkyh dh ckM+ ?ksjs


canh dks m[kkM+uk

Weight per sq m

izfr oxZ ehVj

otu izfr oeh


N exc 4 kg
21049 Dismantling expanded metal, any
thickness or mesh, fixed with steel

or wood fillets, if any

Exc 4 kg

4 fdxzk ls 4 fdxzk ls
vuf/kd
vf/kd
Rs.

Rs.

7.90

11.10

21049 izlkfjr /kkrq fdlh eksVkbZ dh ;k yksgs ;k


ydM+h ds MUMksa esa yxh ;fn dksbZ gks rks] dks
m[kkM+uk

461

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
MISCELLANEOUS
fefJr tkjh
PER RUNNING METRE
21050 Dismantling ballies, hard or
soft wood, any position,
except in posts and struts;
including taking out iron
straps, bolts and nuts, etc.,
if any

Type 3

Type 2

Type 1

uewuk 3

uewuk 2

uewuk 1

Rs.

Rs.

Rs.

2.40

4.80

9.50

21050 l[r ;k uje ydM+h dh fdlh


LFkkiu esa yxh ofYy;ksa dks
m[kkMuk] vk/kkjksa o [kaHkksa dks
NksM+dj] rFkk yksgs dh if;ka

dkoys o f<ofj;k] ;fn dksbZ


gksa] dks fudkyus lfgr

Posts embedded in

PER RUNNING METRE


21051 Dismantling posts or struts
(wood, steel or R.C.C.) any
section, including taking out
embedded portion and
making good disturbed
ground

iz f r ehVj

iz f r ehVj

vk/kkj vr% fcNs

Rs.

Rs.

21051 m[kkM+uk] [kaHksa ;k LrEHk] ydM+h


;k vkjlhlh fdlh [kaM ds
xM+s gq;s Hkkx dks ckgj fudkyus
o fcxM+h tehu dks Bhd djus
lfgr

5.60

10.90

Natural
ground

Concrete, brick work,


masonry, etc.

LoHkkfod
tehu esa

dhV bZV dk;Z] iRFkj fpukbZ

Rs.
21052 Demolishing detached
whole bamboos, any dia

1.60

21052 fdlh Hkh O;kl ds vlaxr caklks


dks m[kkM+uk

DRAINS
ukfy;k
The measurements shall be taken along the centre line of pipe
and fittings. Excavation work shall be measured separately.

PER RUNNING METRE


21053 Demolition and breaking
up drain pipes (Salt
glazed ware, AC or
Reinforced concrete) set in

cement mortar
21054 Dismantling of cast iron or
reinforced concrete drain
pipes, jointed in cement
mortar and taking out of

trenches, if required

uyksa o la;kstuksa ds chp dh dsUnz js[kk ds lkFk&lkFk eki yh


tk;sxhA [kqnkbZ dk;Z izFkd ekis tk;saxsaA
iz f r ehVj

Internal dia of pipe in mm

uy dk Hkhrjh O;kl feeh esa


100

150

200

300

Rs.

Rs.

Rs.

Rs.

14.70

16.50

18.10

20.10

36.40

40.30

44.30

48.30

21053 ukyh uyksa dks m[kkM+uk o


rksMu+ k 'kksj;s Dq r ukyh] ,lh
;k izofyr dahV lhesaV

elkys esa yxs


21054 yksgs ds <ys ;k izofyr
dahV ds ukyh uy] lhesaV
elkys esa tqM+s gqvksa dks
m[kkM+uk rFkk ;fn vko';d

gks rks [kkb;ka [kksnuk

462

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
REMOVING BUILDING MATERIALS

Hkou lkexzh gVkuk


(a) Rates shall apply only where removing of materials, etc. is d ;g njsa dsoy ogka ykxw gksaxh tgka vU;Fkk O;oLFkk ugha dh
not otherwise provided for.
xbZ gSA
(b) One metric tonne shall mean one load. The following [k ,d ehfVd Vu dk eryo *,d Hkkj* gksxkA fuEu dks ,d Hkkj
shall be taken as one load :ekuk tk;sxk :(1)

Asbestos Cement Sheets

65 Sqm

(2)

Bricks

(3)

Brick dust (surkhi)

3 Loads for 1000 Nos.


1.0 cum

(4)

Stone

0.50 cum

(5)

Sand

0.68 cum

(6)
(7)

Timber-Softwood
Timber-Hardwood

1.42 cum
1.13 cum

(8)

Aggregate

0.62 cum

(9)

Tiles (roof) 300x150x50 mm

250 Nos.

(10) Tiles (roof) inter-locking, any pattern


(11) Tiles (roof) country pattern

250 Nos
500 Nos
11.50 sqm

(l2)

Stone slabs 40 mm

(13) Stone slabs 50 mm


(14) Water

(15) Softwood joinery


chowkats
(16) Hardwood joinery
chowkats

excluding

excluding

8.35 sqm
1000 Litres
1.70 cum
1.42 cum

1 ,loslVl lhesaV pknjsa


2 bZVsa
3 bZV dk pwjk lqj[kh
4 iRFkj
5 ckyw
6 yDdM+&uje ydM+h
7 yDdM+&l[r ydM+h
8 feykok
9 Vkbysa Nr 300x150x50 feeh
10 Vkbysa Nr vkoa/kd fdLe dh
11 Vkbysa Nr ns'kh fdLe dh
12 iRFkj ifV;k 40 feeh
13 iRFkj ifV;k 50 feeh
14 ikuh
15 uje ydM+h ds la;kstu] pkS[kV NksMd
+ j
16 l[r ydM+h ds la;kstu] pkS[kV NksMd
+ j

uksV% 15 o 16 [k ds la;kstu laiw.kZ le eksVkbZ leku ekis tk;saxs


fcuk iSuy dh de eksVkbZ] 'kh'kkxjh ;k rkj diMs+ vkfn dh
dVkSrh fd,
(c) An addition of 25 per cent shall be allowed over item x 2 fDoaVy ls ij ds izR;sd ds Hkkj ds fy, p<+kus mrkjus ds
21055 for extra labour in loading, unloading etc., of
vfrfjDr Je ds fy, en 21055 esa vfrfjDr 25% dh vuqefr
articles which weigh over 2 quintals each.
gksxhA
Note : Joinery under (b) 15 and 16 shall be measured overall
as though of uniform thickness without any deduction for
less thickness of panels, glazing or wire cloth etc.

(d) Removal is to be done by the shortest practicable route


and measurement shall be made accordingly,
irrespective of the route actually taken. No additional
price shall be allowed for roads in bad repairs,
gradients or removal over unconsolidated ground.

?k lkexzh ys tkus ds fy, NksVs ls NksVk ekxZ fy;k tk;sxk rFkk


mlh ds vuqlkj eki gksxh u fd okLro esa fy, x;s ekxZ ds]
O;ogkfjd lM+dksa dh cqjh gkyr] xM<+kas ;k vlery tehu ij
fxjkus ds fy, dqN Hkh vfrfjDr ekU; ugha gksxkA

(e) Removal exceeding a distance of 10 km shall either be


done by other agency or under a separate agreement
with the same Contractor.

M+ 10 fdeh ls vf/kd nwjh ij Qsadus dk dk;Z ;k rks fdlh nwljs


laLFkku }kjk fd;k tk;sxk ;k mlh Bsdsnkj ls ,d izFkd
le>kSrs ds rgr gksxkA

463

SECTION 21

SECTION 21DEMOLITION AND DISMANTLING


[kaM 21&rksM+uk vkSj m[kkM+uk
REMOVING BUILDING MATERIALSContd...

Hkou lkexzh gVkuk tkjh


PER LOAD
21055 Removing building materials etc. (other
than spoil payable under items 03028 to
03031 in Section-3Earthwork) to a
distance of 100m or under, beyond the
lead included in the rates, including
loading, unloading and stacking at the

destination
21056 Add for every additional 100 metres or

part thereof (upto 1.0 km total distance)


21057 Add for every additional 500 metres
or part thereof (exc 1.0 km total

distance)

Rs.

izfr *,d Hkkj*


21055 Hkou fuekZ.k lkexzh vkfn dks gVkuk eyos dks
NksM+dj ftldk Hkqxrku [k.M&3 feV~Vh dk;Z
ds varxZr en 03028 ls 03031 esa gksxk njksa
esa nh xbZ nwjh ls 100 eh ;k de ds Qklys ij
Qsaduk] HkjkbZ o fuf'pr LFkku ij fxjkuk

32.40

4.10
1.20

21056 tksMas+ izR;sd vfrfjDr 100 eh ;k mlds Hkkx ds


fy, dqy Qklyk 1-0 fdeh rd
21057 tksMa+s izR;sd vfrfjDr 500eh ;k mlds Hkkx ds
fy, 1-0 fdeh ds dqy Qklys ls vf/kd

464

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


AIR HANDLING UNIT
EACH

SIZE

22001 Supply , install , commissioning


and testing of Fan coil unit
constructed out of 20 G Pre - coated
GI, with 3 Rows Deep cooling coil
3/8" construction incl 12 mm thick
pre - filter, DIDW Centrifugal blower
with single phase direct driven
motor and drain tray made out of
sandwich type in 18G GI
constructions with 25 mm PUF/
Thermocole insulation and 24 G GI
covering complete of nominal

capacity as shown.
22002 Supply , install , commissioning
and testing of Fan coil unit
constructed out of 20 G Pre - coated
GI, with 4 Rows Deep cooling coil
3/8" construction incl 12 mm thick
pre - filter, DIDW Centrifugal blower
with single phase direct driven
motor and drain tray made out of
sandwich type in 18G GI
constructions with 25 mm PUF/
Thermocole insulation and 24 G GI
covering complete of nominal

capacity as shown.

1.0 TR

1.5 TR

2.0 TR

Rs.

Rs.

Rs.

22130.00

23210.00

26900.00

2.5 TR

3.0 TR

Rs.

Rs.

34090.00

33840.00

SIZE
22003 Supply, install,
commis-sioning
and testing of
Double Skin
Floor Mounted
Air Handling
Unit with 4
Rows Deep Coil
of
nominal
capacity
as

shown.

1000
CFM

1200
CFM

1600
CFM

2000
CFM

2500
CFM

3000
CFM

4000
CFM

5000
CFM

6000
CFM

8000
CFM

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

125000.00

140150.00

159080.00

179280.00

215990.00

231050.00

289130.00

20000
CFM

22000
CFM

24000
CFM

25000
CFM

92170.00 98480.00 112370.00

SIZE

10000
CFM

12000
CFM

13000
CFM

Rs.

Rs.

Rs.

352250.00 409270.00 441890.00

SIZE
30000 CFM

35000 CFM

Rs.

Rs.

973420.00

1071990.00

15000
CFM

16000
CFM

18000
CFM

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

498710.00

522190.00

576980.00

698190.00

736060.00

801720.00

829490.00

465

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


AIR HANDLING UNIT Contd...
22004 Supply , install ,
commissioning
and testing of
Double Skin
Floor Mounted
Air Handling
Unit with 6
Rows Deep Coil
of
nominal
capacity
as

shown.

SIZE
1000
CFM

1200
CFM

1600
CFM

2000
CFM

2500
CFM

3000
CFM

4000
CFM

5000
CFM

6000
CFM

8000
CFM

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

137620.00

154030.00

98480.00 106060.00 122470.00

175500.00 199480.00

241150.00

262610.00 330790.00

SIZE

10000
CFM

12000
CFM

13000
CFM

Rs.

Rs.

Rs.

405280.00 472190.00 511330.00

15000
CFM

16000
CFM

18000
CFM

20000
CFM

22000
CFM

24000
CFM

25000
CFM

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

576980.00

606020.00

671670.00

804240.00

852220.00

927970.00

962060.00

SIZE
30000 CFM

35000 CFM

Rs.

22005 Supply , install ,


commissioning
and testing of
Double Skin
Ceiling Suspended
Air
Handling Unit
with 6 Rows
Deep Coil of
n o m i n a l
capacity
as

shown.

Rs.

1131240.00

1256230.00

SIZE
1000
CFM

1200
CFM

1600
CFM

2000
CFM

2500
CFM

3000
CFM

4000
CFM

5000
CFM

6000
CFM

7000
CFM

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

117420.00

131310.00

84590.00 92170.00 103530.00

148980.00 178020.00

207060.00

249990.00 271450.00

SIZE

22006 Supply , install ,


commissioning
and testing of
Double Skin
Ceiling
Suspended
Air
Handling Unit
with 4 Rows
Deep Coil of
nominal capacity

as shown.

8000 CFM

9000 CFM

10000 CFM

Rs.

Rs.

Rs.

294180.00

337100.00

364880.00

SIZE
1000
CFM

1200
CFM

1600
CFM

2000
CFM

2500
CFM

3000
CFM

4000
CFM

5000
CFM

6000
CFM

7000
CFM

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

93430.00

107320.00

117420.00

78280.00 84590.00

132570.00 157820.00

181810.00

218420.00 234840.00

466

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


AIR HANDLING UNIT Contd...
SIZE
8000 CFM

9000 CFM

10000 CFM

Rs.

Rs.

Rs.

251450.00

290390.00

344850.00

AIR CURTAINS
EACH
22007 Supply, install,
commissioning
and testing of
commercial Air
curtain unit for
prevention of dust
and conditioned
air losses, single
phase, 220 V, 50
HZ, made out of
MS/CRCA sheet
of
minimum
thickness
18
gauge finished
with two coats of
red oxide primer
and final coat of
synthetic enamel
paint
(oven
baked) with MS CRC 18 gauge
square perforated
suction grills,
Aluminium alloy
fans and single
phase electric
motor, nozzles
etc, complete with
fittings
and
accessories so as
to produce 1 - 1.5
m/sec air velocity
at floor level for
door opening as

specified.

DOOR OPENING SIZE


28" x 78" 34" x 78"
Rs.

40" x 78"

46" x 78"

52" x 78"

58" x 78"

64" x 78"

70" x 78"

28" x 84"

34" x 84"

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

35351.00

37876.10

40401.20

42673.80

45451.30

49870.20

25250.70

35098.50

Rs.

22725.70 32573.50

DOOR OPENING SIZE


40" x 84"

46" x 84"

52" x 84"

58" x 84"

64" x 84"

Rs.

Rs.

Rs.

Rs.

Rs.

37876.10

40401.20

42926.30

45198.80

47976.40

467

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


AIR CURTAINS Contd...
EACH
22008 Supply, install,
commissioning
and testing of
commercial Air
curtain unit for
prevention of
dust
and
conditioned
air losses, three
phase 440 V,
50 Hz, made
out of MS/
CRCA sheet of
minimum
thickness 18
gauge finished
with two coats
of red oxide
primer and
final coat of
synthetic
enamel paint
(oven baked)
with MS - CRC
18
gauge
s q u a r e
perforated
suction grills,
Aluminium
alloy fans and
single phase
electric motor,
nozzles etc,
complete with
fittings and
accessories so
as to produce
1- 1.5 m/sec
air velocity at
floor level for
door opening
as specified.

DOOR OPENING SIZE


28" x 90" 34" x 90"
Rs.

40" x 90"

46" x 90"

52" x 90"

58" x 90"

64" x 90"

70" x 90"

28" x 96"

34" x 96"

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

42673.80

47976.40

58076.70

65651.90

73227.20

82696.20

46713.90

50501.50

Rs.

34088.50 37876.10

DOOR OPENING SIZE


40" x 96"

46" x 96"

52" x 96"

58" x 96"

64" x 90"

70" x 96"

Rs.

Rs.

Rs.

Rs.

Rs.

Rs

55299.10

60601.80

70702.10

78277.30

85852.50

95321.60

468

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


COOLING TOWERS
EACH

SIZE

22009 Supply, installation,


commissioning and
testing of induced draft
top
discharge
counterflow type FRP
Cooling
Tower
(Rectangular/Round
bottle shape) with FRP
body and base, water
spray headers, cooling
tower fills, fan with
motor, supporting base
frames,
as
per
manufacturer's standard

instructions.

7 TR

10 TR

15 TR

17.5 TR

20 TR

Rs.

Rs.

Rs.

Rs.

Rs.

51110.00

53270.00

60540.00

67360.00

67740.00

SIZE

25 TR

30 TR

35 TR

40 TR

50 TR

Rs.

Rs.

Rs.

Rs.

Rs.

86530.00

94830.00

110980.00

128170.00

80350.00

SIZE

60 TR

70 TR

80 TR

90 TR

100 TR

Rs.

Rs.

Rs.

Rs.

Rs.

155580.00

178940.00

188230.00

203640.00

147050.00

SIZE

110 TR

125 TR

150 TR

175 TR

200 TR

Rs.

Rs.

Rs.

Rs.

Rs.

237360.00

286300.00

306620.00

357490.00

234880.00

SIZE

225 TR

250 TR

275 TR

300 TR

325 TR

Rs.

Rs.

Rs.

Rs.

Rs.

386280.00

472470.00

517940.00

567350.00

603330.00

469

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


COOLING TOWERS Contd...
SIZE

350 TR

375 TR

400 TR

425 TR

450 TR

Rs.

Rs.

Rs.

Rs.

Rs.

631420.00

711190.00

736390.00

797750.00

779690.00

SIZE

500 TR

550 TR

600 TR

665 TR

700 TR

Rs.

Rs.

Rs.

Rs.

Rs.

914240.00

1011380.00

1245410.00

1188670.00

1397570.00

SIZE

750 TR

800 TR

900 TR

1000 TR

Rs.

Rs.

Rs.

Rs.

1336410.00

1745660.00

2018670.00

2540430.00

AIR COOLED RECIPROCATING CHILLERS


22010 Supply , install , commissioning and testing of Air
Cooled Reciprocating
Chillers with stepped
capacity
control,
comprising of Semi Hermetic/Open Type
Compressors,
DX
Evaporator, Shell and
Tube Condenser,suitable
expansion
device,
suitable for operation on
R - 22 /R - 407c/R - 410a
refrigerants and of
nominal capacity as

shown.

SIZE
30 TR

60 TR

90 TR

110 TR

Rs.

Rs.

Rs.

Rs.

856290.00

1603590.00

2241900.00

2747890.00

470

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


CHILLERS
AIR COOLED RECIPROCATING CHILLERS
EACH

SIZE

22011 Supply , install , commissioning and testing of


Water Cooled Reciprocating Chillers with
stepped
capacity
control, comprising of
Semi - Hermetic/Open
Type Compressors, DX
Evaporator, Shell and
Tube Condenser,suitable
expansion
device,
suitable for operation on
R - 22 /R - 407c/R - 410a
refrigerants and of
nominal capacity as

shown.

33TR

66 TR

99 TR

135 TR

Rs.

Rs.

Rs.

Rs.

825150.00

1424540.00

2023940.00

2724540.00

AIR COOLED SCREW CHILLERS


EACH

SIZE

22012 Supply , install , commissioning and testing of


Air Cooled Screw
Chillers with sliding
type capacity control,
comprising of one or
multiple
Semi
Hermetic/Hermetic
Compressors,
DX
Evaporator, Shell and
Tube Condenser, suitable
expansion
device,
suitable for operation on
R - 22 / R - 407c/R - 410a
R - 134a refrigerants and
of nominal capacity as

shown.

110 TR

140 TR

180 TR

220 TR

250 TR

Rs.

Rs.

Rs.

Rs.

Rs.

3375730.00

4058920.00

5407960.00

6076010.00

280 TR

300 TR

330 TR

390 TR

420 TR

Rs.

Rs.

Rs.

Rs.

Rs.

6551470.00

7205000.00

8098910.00

9077060.00

9534140.00

2753270.00

SIZE

471

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


AIR COOLED SCREW CHILLERS Contd...
EACH

SIZE

22013 Supply , install , commissioning and testing of Air


Cooled Screw Chillers
with sliding type capacity
control, comprising of
one or multiple Semi Hermetic/Hermetic
Compressors,
DX
Evaporator, Shell and
Tube Condenser, suitable
expansion
device,
suitable for operation on
R - 22/R - 407c/R - 410a/
R - 134a refrigerants and
of nominal capacity as

shown.

60 TR

75 TR

102 TR

145 TR

150 TR

Rs.

Rs.

Rs.

Rs.

Rs.

1460770.00

1833130.00

2357430.00

3146560.00

3254550.00

SIZE

177 TR

204 TR

206 TR

247 TR

290 TR

320 TR

366 TR

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

4353500.00

4279090.00

5071540.00

5917970.00

6457000.00

7163090.00

3813180.00

WATER COOLED SCREW CHILLERS


22014 Supply , install , commissioning and testing of
Water Cooled Screw
Chillers with sliding type
capacity
control ,
comprising of one or
multiple
Semi
Hermetic/Hermetic
Compressors,
DX
Evaporator, Shell and
Tube Condenser and
suitable
expansion
device. The Chiller shall
be suitable for operation
on R - 22 /R - 407c/R 410a refrigerants and of
nominal capacity as

shown.

SIZE
70 TR

85 TR

115 TR

135 TR

160 TR

Rs.

Rs.

Rs.

Rs.

Rs.

1412460.00

1555270.00

1845730.00

2152300.00

2504300.00

472

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


WATER COOLED SCREW CHILLERS
SIZE

22015 Supply , install , commissioning and testing of


Water Cooled Screw
Chillers with sliding type
capacity
control,
comprising of one or
multiple Semi - Hermetic/
Hermetic Compressors,
Flooded Evaporator, Shell
and Tube Condenser,
suitable
expansion
device, suitable for
operation on R - 134a
refrigerant and of
nominal capacity as

shown.

175 TR

225 TR

270 TR

315 TR

345 TR

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

2718590.00

3471510.00

4157910.00

4715560.00

5136690.00

5744030.00

SIZE
110 TR

134 TR

147 TR

150 TR

152 TR

Rs.

Rs.

Rs.

Rs.

Rs.

2824480.00

3641810.00

3740990.00

3405530.00

4092580.00

SIZE

163 TR

180 TR

200 TR

220 TR

250 TR

Rs.

Rs.

Rs.

Rs.

Rs.

4466620.00

3871510.00

3995720.00

5381980.00

5748130.00

SIZE

285 TR

299 TR

322 TR

329 TR

350 TR

Rs.

Rs.

Rs.

Rs.

Rs.

6835790.00

6860470.00

7182990.00

8070960.00

6856890.00

370 TR

375 TR

400 TR

410 TR

Rs.

Rs.

Rs.

Rs.

7910400.00

8835850.00

8068260.00

9221460.00

SIZE

400 TR

473

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


AIR COOLED SCROLL CHILLER
EACH

SIZE

22016 Supply , install , commissioning


and testing of Air Cooled Scroll
Chillers, with multi compressors,
and comprising of one or multiple
Semi - Hermetic/Hermetic/
Open Type Compressors, DX
Evaporator, Shell and Tube
Condenser,suitable expansion
device,suitable for operation on
R- 22/R - 407 c/R - 410a
refrigerants and of nominal

capacity as shown.

10 TR

24 TR

36 TR

48 TR

80 TR

Rs.

Rs.

Rs.

Rs.

Rs.

434130.00

807880.00

1130500.00

1410260.00

2130080.00

WATER COOLED SCROLL CHILLERS


EACH
22017 Supply , install , commissioning
and testing of Water Cooled
Scroll Chillers, with multi
compressors, comprising of
Semi - Hermetic/Hermetic/
Open Type Compress-ors, DX
Evaporator, Shell and Tube
Condenser,suitable expansion
device,suitable for operation on
R - 22 /R - 407 C/R 410a
refrigerants and of nominal

capacity as shown.

SIZE
11 TR

26 TR

39 TR

52 TR

85 TR

Rs.

Rs.

Rs.

Rs.

Rs.

428440.00

716940.00

991240.00

1350570.00

2022950.00

WATER COOLED CENTRIFUGAL CHILLER


EACH
22018 "Supply , install , commissioning
and testing of Water Cooled
Centrifugal Chillers, with
Variable Frequency Drive
(VFD),comprising of centrifugal
compressors, DX Evaporator,
Shell
and
Tube
Condenser,suitable expansion
device , suitable for operation on
R - 134a refrigerant and of
nominal capacity as shown.
Note: The above cost do not
include the cost of Variable
Frequency Drive (VFD).
However, VFDs are to be
provided with Centrifugal
Chillers
for
energy

conservation."

SIZE
300 TR

350 TR

400 TR

450 TR

500 TR

Rs.

Rs.

Rs.

Rs.

Rs.

7293430.00

7679030.00

8064640.00

8450250.00

8835850.00

474

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


WATER COOLED CENTRIFUGAL CHILLER Contd...
EACH
22019 "Supply , install , commissioning
and testing of Water Cooled
Centrifugal Chillers, with Variable
Frequency Drive (VFD),comprising
of centrifugal compressors, DX
Evaporator, Shell and Tube
Condenser,suitable expansion
device , suitable for operation on R 134a refrigerant and of nominal
capacity as shown.
Note: The above cost do not include
the cost of Variable Frequency Drive
(VFD). However, VFDs are to be
provided with Centrifugal Chillers

for energy conservation."

SIZE
550 TR

600 TR

650 TR

700 TR

750 TR

Rs.

Rs.

Rs.

Rs.

Rs.

9607070.00

9992670.00 10146920.00 10378280.00 10763890.00

DUCT INSULATION
Square Metre
22020 M&L for duct insulation with
resin bonded fibre glass wool roll
of density 24 kg/Cum, with
factory laminated aluminium
vapour barrier, thickness of
insulation as specified and

including the following:(a) M&L for cleaning the duct


surface (to be insulated ) by
scrapping carefully with wire
brush etc. to make the surface
completely free of millscale, dirt,
dust, grease and other foreign
materials, taking special care so
that all duct joints are sealed
against any leakage.
(b) M&L for applying rubber
based adhesive CPRX compound.
(c) M&L for sealing of all
longitudinal joints and circular
overlaps with and including
Aluminium foil tape 50 mm wide,
to make the insulation leakproof.
(d) M & L for securing the
insulation with and including
mechanically fastened nylon/
steel straps of size 12 mm/50 mm
at maximum intervals of 1.2 mtr.

SIZE
25 MM

40 MM

50 MM

RS.

RS.

RS.

260.00

350.00

390.00

475

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


DUCT INSULATION Contd.....
PGI SHEET DUCT
RS.

Square Metre

22021 Supply , assembly and erection of GI sheet with C


& SS rectangular/square duct made out of 'L'
shaped hollow profile, duly factory boxed, incl all
accessories such as Corner, Cleat, Carriage bolt,
Gasket and appropriate sealant on longitudinal
1220.00
joints etc complete of size 26 Gauge.
All as per above Item , but of size 24 Gauge.

1340.00

Supply , assembly and erection of GI sheet with


TDF flange rectangular/square duct made out of
'L' shaped hollow profile, duly factory boxed, incl
all accessories such as Corner, Cleat, Carriage bolt,
Gasket and appropriate sealant on longitudinal
1400.00
joints etc complete of size 26 Gauge.
All as per above Item , but of size 24 Gauge. 1510.00
All as per above Item , but of size 22 Gauge.

1640.00

All as per above Item , but of size 20 Gauge.

1830.00

All as per above Item , but of size 18 Gauge.

2080.00

PACKAGE UNIT

EACH
22022 Supply , install , commissioning
and testing of Air Cooled Packaged
Air Conditioners, comprising of
Hermetic/Semi - Hermetically
sealed
Reciprocating
or
Hermetically sealed Scroll
Compressors with microprocessor
based control, including copper
refirgerant piping, electrtical
interconnection between indoor
and outdoor units , suitable for
operation on R - 22/R - 407c/R 410a refrigerants and of nominal

capacity as shown.
22023 Supply , install , commissioning
and testing of Water Cooled
Packaged Air Conditioners,
comprising of Hermetic/Semi Hermetically sealed Reciprocating
or Hermetically sealed Scroll
Compressors with microprocessor
based control, including copper
refirgerant piping, electrtical
interconnection between indoor
and outdoor units, suitable for
operation on R - 22/R - 407c/R 410a refrigerants and of nominal

capacity as shown.

SIZE
5.5 TR

8.75 TR

11 TR

16.5 TR

22 TR

Rs.

Rs.

Rs.

Rs.

Rs.

214980.00

319990.00

369600.00

526700.00

654870.00

SIZE
5.5 TR

11 TR

16.5 TR

Rs.

Rs.

Rs.

210850.00

348110.00

493630.00

476

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


M S PIPES
PER RUNNING METRE

BORE OF PIPE

22024 Supply and lay M S Pipes heavy


grade with all fittings laid in
floors or fixed to walls and
ceilings etc of sizes as shown.

20 MM

25 MM

32 MM

40 MM

50 MM

Rs.

Rs.

Rs.

Rs.

Rs.

190.00

280.00

360.00

410.00

560.00

65 MM

80 MM

100 MM

125 MM

150 MM

Rs.

Rs.

Rs.

Rs.

Rs.

690.00

870.00

1220.00

1470.00

1750.00

BORE OF PIPE

PUF INSULATION FOR MS PIPE


PER RUNNING METRE
22025 M & L for Insulation of M S
Pipe with PUF slab 30 mm
thick with and including
applying
bituminuous
compound and GI cladding
with 26 gauge GI sheet
complete of sizes as shown.
22026 M & L for Insulation of M S
Pipe with PUF slab 40 mm
thick with and including
applying
bituminuous
compound and GI cladding
with 26 gauge GI sheet
complete of sizes as shown.

BORE OF PIPE
20 MM

25 MM

32 MM

40 MM

50 MM

65 MM

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

58.00

72.00

91.00

115.00

143.00

186.00

BORE OF PIPE
80 MM

100 MM

125 MM

150 MM

Rs.

Rs.

Rs.

Rs.

260.00

322.00

403.00

483.00

PRE INSULATED MS PIPES


PER RUNNING METRE
22027M & L for Pre - insulated
MS pipe , Class 'C' having
thickness
of
PUF
insulation 36 mm of
density 36 Kg/Cum and 26
gauge GI cladding
complete suitable for
above ground as per sizes

shown.

20 MM

25 MM

32 MM

40 MM

50 MM

Rs.

Rs.

Rs.

Rs.

Rs.

480.00

560.00

650.00

730.00

920.00

65 MM

80 MM

100 MM

125 MM

150 MM

Rs.

Rs.

Rs.

Rs.

Rs.

1110.00

1400.00

1860.00

2210.00

2580.00

477

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


UNDERDECK INSULATION
Square Metre

Rs.

22028 "M & L for underdeck insulation for RCC roof with
bonded fibre glass wool of density 48 Kg/Cum, 75
mm thick, suitably factory laminated with
aluminium foil having flange on one side, backed
up by scrim and kraft paper, comprising of the
following (insulating material shall conform to BS 476, Part 4,5, 6 & 7):-(a) S & F 50 x 50 mm or 75 x 75
mm slotted angles 50 mm wide, fixed to the ceiling
by means of rawl plug 600 mm centre to centre.(b)
Supply and draw GI tie wire 22 Gauge from vertical
slots, for holding the insulating material in position
with and including GI washer.(c) S & F aluminium
foil, adhesive tape 50 mm for sealing of aluminium
foil flanges.(d) Providing additional support to
the insulation with and including chicken wire
mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal
construction, stretched firmly over the insulation

and fixed."

1020.00

22029 "M & L for underdeck insulation for metal roof


with bonded fibre glass wool of density 24
Kg/Cum, 50 mm thick, suitably factory
laminated with aluminium foil backed up by
scrim and kraft paper (FSK), facing with 50
mm projection for overlap and butting
comprising of the following:- (insulating
material shall conform to BS - 476, Part 4,5, 6
& 7):-(a) Supply and fix 6 mm dia M S rods
between purlins suitably for supporting the
required thickness of insulation material
beneath the metal roof.(b) Supply and fix 22
SWG GI wires supports for insulation.(c)
Supply and fix chicken wire mesh 12.5 mm x
22 SWG of hexagonal construction below the

insulation for supporting the same."

480.00

22030All as per above Item No. 22029 but with


bonded fibreglass wool insulation of density

16 Kg/Cum, 50 mm thick.

390.00

22031 All as per above Item No. 22029 but with


bonded fibreglass wool insulation of density

16 Kg/Cum, 100 mm thick.

570.00

Square Metre
22032 M&L for under deck insulation with PUF slab
including application of cold bitumen on PUF
slab, steel wire of size 46 gauge fixed with
RCC roof by means of MS screws, washers etc
for fastening of PUF slab, suitable for the PUF

slab to be pasted on RCC roof slab.


22033 -ditto- but with MS tubular square pipe grid
framework 20X20 mm suitable for steel sheet

roof

60 mm thick
PUF Slab

90 mm thick
PUF Slab

Rs.

Rs.

1030.00

1370.00

1440.00

1780.00

478

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


VLT HVAC DRIVE
22034 Supply, installation, commis-sioning
and testing of Variable Frequency
Drives with IP 55 enclosures and mains
disconnect switch comprising of the
following:(a) Built in dual 5% impedance DC link
reactor (harmonic filters) on the positive
and negative rails of the DC bus of the
Variable Frequency Drive.
(b) Built in EMC filters (electro magnetic
compatibility filters) for restriction of
conducted emissions to comply with
IEC61800:3 (un restricted distribution)
:2004 Category C 1 (50 meter).
(c) Three feedback PID controller having
capability to simultaneously accept 3
feedback signals from temperature
sensors or pressure sensors for process
optimization and accordingly control
the speed of the AHUs or pumps.
(d) Integral graphical keypad.
Note: (i) Cost of temperature sensor and
control cables not included.
(ii) Separate Starter not required for

switching on motor and pump.


22035 Supply, installation, commis-sioning
and testing of Variable Frequency
Drives with IP 55 enclosures and mains
disconnect switch comprising of the
following:(a) Built in dual 5% impedance DC link
reactor (harmonic filters) on the positive
and negative rails of the DC bus of the
Variable Frequency Drive.
(b) Built in EMC filters (electro magnetic
compatibility filters) for restriction of
conducted emissions to comply with
IEC61800:3 (unrestricted distribution) :2004
Category C 1 (50 meter).
(c) Three feedback PID controller having
capability to simultaneously accept 3
feedback signals from temperature
sensors or pressure sensors for process
optimization and accordingly control
the speed of the AHUs or pumps.
(d) Integral graphical keypad.
Note: (i) Cost of temperature sensor and
control cables not included.
(ii) Separate Starter not required for

switching on motor and pump.

POWER
SIZE
1.1 KW

POWER
SIZE
1.5 KW

POWER
SIZE
2.2 KW

POWER
SIZE
3 KW

POWER
SIZE
4 KW

Rs.

Rs.

Rs.

Rs.

Rs.

65810.00

72270.00

82930.00

89970.00

94660.00

POWER
SIZE
5.5 KW

POWER
SIZE
7.5 KW

POWER
SIZE
11 KW

POWER
SIZE
15 KW

POWER
SIZE
18.5 KW

POWER
SIZE
22 KW

POWER
SIZE
30 KW

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

106100.00

116660.00

156550.00

174640.00

212880.00

245440.00

282100.00

479

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


WALK - IN COLD ROOM & MORTUARY CABINET
Rs.

EACH
22036 Supply, installation, testing and commissioning of
Walk - in cold room of two chambers for Medical
Storage of nominal size 5'x5'x8' consisting of wall
and ceiling panel made out of PGI sheet filled with
60 mm PUF insulation, anti skid GI flooring on 60 mm
PUF, door of suitable dimension, hydraulic door
closer, digital temperature indicator, Air cooled
medium temperature split unit of 2 HP rating with
Reciprocating/Scroll Compressors working on R 22/R - 410a refrigerants to maintain temperature of
4+/- 2 degree Centigrade at an ambient temperature

of 30 degree centigrade.

448470.00

22037 All as per above Item, but of size 12' x 10' x8' and

cooling machine of rating 3 HP.

656520.00

22038 Supply, installation, testing and commissioning of


Walk - in cold room of two chambers ,Freezer Room
of size 8'x8'x8' consisting of wall and ceiling panel
made out of PGI sheet filled with 120 mm PUF
insulation, and Ante Room of size 5'x5'x8' consisting
of wall and ceiling panel made out of PGI sheet filled
with 60 mm PUF insulation, for Blood Bank and
other low temperature application , anti skid GI
flooring on 60 mm PUF, door of suitable dimension,
hydraulic door closer, digital temperature indicator,
Air cooled low temperature split unit of 2 HP rating
with Reciprocating/Scroll Compressors working on
R - 22/R - 410a refrigerants to maintain temperature
of 4+/- 2 degree Centigrade at an ambient

temperature of 30 degree centigrade.

1171640.00

22039 All as per above Item, but Freezer Room of size 12'
x 10' x8' and cooling machine of rating 3 HP.

1489800.00

22040 Supply, install,commissioning and testing


Mortuary cabinet suitable for single phase, 230 V,
50 Hz, with 0.55 mm thick exterior & interior
finish pre painted GI sheet, 0.5 mm thick front
finish in stainless, including vapour proof
incandescent lamp, electric temperature indicator
cum controller, 3 phase carriage assembly, one
piece stainless steel tray, inbuilt power panel etc.
suitable for unitary type refrigeration system and
temperature range of 4-6C of capacity :(a) 02 Body

479320.00

(b) 04 Body

958630.00

(c) 06 Body

1438940.00

480

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


ICE MAKING MACHINE
EACH

Rs.

22041 Ice making Machine of capacity 60 Ltrs, self


standing, made out of stainless steel body, air
cooled with eco friendly refrigerant R- 404a
working on single phase power supply 29 Kg/24
hrs rated capacity and 9 Kg ice storage bin.

73700.00

22042 All as per above Item but of capacity 90 Ltrs


43 Kg/24 hrs rated capacity and 25 Kg ice

storage bin.

92400.00

22043 All as per above Item but of capacity 260 Ltrs


100 Kg/24 hrs rated capacity and 60 Kg ice

storage bin.

147400.00

22044 All as per above Item but of capacity 350 Ltrs


155 Kg/24 hrs rated capacity and 65 Kg ice

storage bin.

190300.00

APPLIANCES
METAL TOP DEEP FREEZER
22045 Supply, installation,
commis-sioning of Metal
Top Deep Freezer single
phase 240 volt, 50 Hz

90/100

120

150

200/205

300/320

405/425

500

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

14850.00

16450.00

16500.00

18810.00

23600.00

GLASS TOP DEEP FREEZER


22046 Supply,
installation,
commissioning of Glass
Top Deep Freezer single
phase 240 volt, 50 Hz

140

205/220

320

405/425

Rs.

Rs.

Rs.

Rs.

20900.00

24750.00

29420.00

33000.00

BOTTLE COOLER
22047 Supply, installation, commis-sioning
of Bottle Cooler single phase 240 volt,

50 Hz

300

400

500

Rs.

Rs.

Rs.

29700.00

36300.00

39600.00

WATER DISPENSER
22048 Supply only bottled water dispenser, having
option of dispensing hot and cold water with
cooling capacity 3 ltrs/hr and tank capacity of 3.4
ltrs, heating capacity 6 ltrs/hr and tank capacity

1.6 ltrs, working in R - 134a refrigerant.


22049 Supply only bottled water dispenser, having
option of dispensing hot and cold water with
cooling capacity 2 ltrs/hr and tank capacity of 1.5
ltrs, heating capacity 5 ltrs/hr and tank capacity

0.8 ltrs, working in R - 134a refrigerant.

Rs.

10450.00

9350.00

28210.00 32450.00

481

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


WATER COOLER
EACH
22050 Supply, installation,
commis-sioning of Water
cooler partially stainless
steel, electric driven
single phase having
approx storage and
nominal
cooling
capacity as shown.
22051 Supply, installation,
commis-sioning of Water
cooler fully stainless
steel, electric driven
single phase having
approx storage and
nominal
cooling
capacity as shown.

SIZES IN LTRS
20/20

20/40

40/40

40/80

60/120

150/150

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

18250.00

22760.00

27930.00

29910.00

37720.00

44210.00

20/20

20/40

40/40

40/80

60/120

150/150

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

20890.00

24740.00

29910.00

32440.00

41570.00

50040.00

SIZES IN LTRS

SPLIT AC UNIT
EACH
WALL MOUNTED NON - STAR RATED
22052 Supply and install hi wall split units
indoor/outdoor complete with
cordless remote control unit and with
in built air ioniser and Plasma filter
for better indoor air quality of

capacity as shown.

SIZES
1.0 TR

1.5 TR

2.0 TR

Rs.

Rs.

Rs.

28800.00

33330.00

42950.00

WALL MOUNTED STAR RATED


22053 Supply and install hi wall split units
indoor/outdoor complete with
cordless remote control unit and with
in built air ioniser and Plasma filter
for better indoor air quality with
minimum 3 star rating and EER 3.2

of capacity as shown.
22054 Supply and install hi wall split units
indoor/outdoor complete with
cordless remote control unit and with
in built air ioniser and Plasma filter
for better indoor air quality with
minimum 4 star rating and EER

3.2.of capacity as shown.

SIZES
1.0 TR

1.5 TR

2.0 TR

Rs.

Rs.

Rs.

31680.00

43100.00

52150.00

SIZES
2.0 TR
Rs.

70540.00

482

SECTION 22

SECTION 22 HEATING, VENTILATION AND AIR CONDITIONING


SPLIT AC UNIT Contd..
EACH
22055 Supply and install hi wall split units
indoor/outdoor complete with cordless
remote control unit and with in built air
ioniser and Plasma filter for better indoor
air quality with minimum 5 star rating and

EER 3.2.of capacity as shown.


WALL MOUNTED NON - STAR
RATED WITH COOLING &
HEATING FUNCTION
22056 Supply and install hi wall split units indoor/
outdoor complete with cordless remote
control unit and with cooling and heating

function of capacity as shown.

SIZES
1.0 TR

1.5 TR

Rs.

Rs.

47770.00

58040.00

SIZES
1.5 TR

2.0 TR

Rs.

Rs.

64940.00

75720.00

WALL MOUNTED NON - STAR


RATED WITH COOLING &
HEATING FUNCTION AND
DIGITAL INVERTER
22057 Supply and install hi wall split units indoor/
outdoor complete with cordless remote control
unit and with in built Heating and Cooling
arrangement and Digital Inverter twin rotary

of capacity as shown.

SIZES
1.5 TR

2.0 TR

Rs.

Rs.

84500.00

100450.00

CASSETTE AC NON - STAR RATED


22058 Supply and install Cassette type units
indoor/outdoor complete with cordless
remote control unit ,twin rotary
compressor, single phase units 220V 240V, 50 Hz of capacity as shown.

SIZES
1.5 TR

2.0 TR

3.0 TR

4.0 TR

Rs.

Rs.

Rs.

Rs.

64230.00

71050.00

1.5 TR

2.0 TR

3.0 TR

3.7 TR

Rs.

Rs.

Rs.

Rs.

99300.00

118200.00

102600.00 127250.00

CASSETTE TYPE NON - STAR RATED


WITH HEATING & COOLING
FUNCTION & DIGITAL INVERTER
22059 Supply and install Cassette type units
indoor/outdoor complete with cordless
remote control unit and with in built
Heating and Cooling arrangement and
Digital Inverter twin rotary compressor,
single phase units 220V - 240V, 50 Hz of

capacity as shown.

SIZES

VERTICAL PACK NON - STAR RATED


22060 Supply and install vertical pack type
units indoor/outdoor complete with
cordless remote control unit, twin rotary
compressor, single phase units 220V 240V, 50 Hz of capacity as shown.

178500.00 207250.00

SIZES
2.5 TR

3.5 TR

4.5 TR

Rs.

Rs.

Rs.

68250.00

83200.00

102750.00

SECTION 23

483

SECTION 23 LIFTS

EACH

Numbers of passengers

08
10
13
16
20
23001 Design supply, install
testing & commissioning
passengers lift, speed 1.5
metre/sec, lift with
single speed motor 415
volts, 3 phase, AC 50 Hz
supply conforming to IS14665, suitable to serve G
+ 04 upper floors with AC
Variable Voltage &
Variable Frequency drive
(VVVF drive) complete
with all standard
accessories, simplex
automatic & manual
dual
controlled
operation with/without
attendant, centre opening
doors with door drive
(electric motor driven
mechanism), sliding
stainless steel doors,
automatic rescue device
(ARD) system, 3D infra
red sensor in full height of
door & built in
announcing
system
without hand set (04 Nos,
one each in car, Machine
room & near Ground floor
landing door) complete
18,00,000 20,00,000 22,00,000 25,00,000 30,00,000
all as specified
23002 Extra for additional
90,000
floor
1,00,000 1,10,000
1,25,000 1,50,000
23003 Extra for increase in
40,000
44,000
50,000
60,000
speed by 0.5 m/sec 36,000

SECTION 23

484

SECTION 23 LIFTS
EACH
23004 Design, supply, install, testing
& commissioning goods lift ,
speed 0.5 metre/sec with single
speed motor, 415 volts, 3 phase
AC 50 Hz supply, conforming
to IS-14665 and as amended,
suitable to serve G+04 upper
floors with AC Variable
Voltage
&
Variable
Frequency Drive (VVVF drive)
complete with all standard
accessories, simplex automatic
& manual dual controlled
operation
with/without
attendant, centre opening doors
with door drive (electric motor
driven mechanism), sliding
stainless steel doors, automatic
rescue device (ARD) system, 3D
infra red sensor in full height
of door & built in announcing
system without hand set (03
Nos, one each in car, Machine
room & near Ground floor
landing door) complete all as

specified
23005 Extra for additional floor for

each lift
23006 Extra for increase in speed by

0.5 m/sec
23007 to 23008

Weight
500 Kg

1000 Kg

1500 Kg

2000 Kg

16,00,000

18,00,000

24,00,000

28,00,000

80,000

90,000

1,20,000

1,40,000

32,000

36,000

48,000

56,000

485

SECTION 26

SECTION 26SOLAR WATER SYSTEM


(a)

Rate of solar water system includes the


cost of backup stainless steel hot water
tank only insultated but does not include
the cost of cold water tank, cold water
piping and hot water piping.
EACH
M&L
Rs.

26001 Supply, Install, Testing and Commissioning


of 'Solar Hot Water System' (Flat Plate
Collector) based on indirect transfer of heat

of capacity 100 LPD.

26002 -do- but 200 LPD

26003 -do- but 300 LPD

26004 -do- but 400 LPD

26005 -do- but 500 LPD

26006 -do- but 600 LPD

26007 -do- but 700 LPD

26008 -do- but 900 LPD

26009 -do-but 1000 LPD

26010 -do-but 1500 LPD

26011 -do- but 2000 LPD

42000.00
78200.00
106200.00
138400.00
166800.00
205000.00
238100.00
300300.00
327200.00
491350.00
649600.00

26012 Supply,
Install,
Testing
and
Commissioning of SOLAR WATER
SYSTEM' (Evacuated Tube Collector)
based on direct transferring of heat of

capacity 100 LPD.

26013 -do-but 150 LPD

26014 -do- but 200 LPD

26015 -do- but 250 LPD

26016 -do-but 300 LPD

26017 -do- but 500 LPD

26018 -do- but 1000 LPD

26019 -do-but 1500 LPD

26020 -do- but 2000 LPD

26021 -do-but 2500 LPD

26022 -do- but 3000 LPD

26023 -do- but 4000 LPD

26024 -do- but 5000 LPD

22600.00
33000.00
35900.00
44200.00
52900.00
95000.00
155200.00
221300.00
303400.00
373900.00
437500.00
581800.00
727200.00

PER RUNNING METRE


26025 Hot water pipe duly insulated with glass
wool and aluminium cladding 15 mm

bore

510.00

26026
26027
26028
26029
26030
26031

600.00
680.00
860.00
915.00
1120.00
1300.00

-do- as in item 26025 but 20 mm bore

-do-but 25 mm bore

-do- but 32 mm bore

-do- but 40 mm bore

-do-but 50 mm bore

-do- but 80 mm bore

SECTION 27

486

SECTION 27 FIRE HYDRANT, FIRE DETECTION AND ALARM SYSTEM


FIRE HYDRANT AND SPRINKLER SYSTEM
PUMPS
M&L
Rs.

EACH SET
27001 Fire pump diesel engine driven horizontal
end suction, centrifugal type confirming
to IS- 12469 1988 with CI casing , bronze
impeller and stainless steel shaft mounted
on heavy duty bearings suitable for
continuous operation with 'range of
operation' 0 % to 150 % of rated capacity
for 440 V , 3 phase, 50 Hz AC supply 70 m

Head. 1620 LPM discharge

546310.00

27002 ditto but 2280 LPM discharge

605850.00

27003 ditto but 2640 LPM discharge

734590.00

27004 ditto but 2850 LPM discharge

803640.00

27005 ditto but 4560 LPM discharge

881250.00

27006 All as per item 27001 but 90m Head,


1620 LPM discharge

645290.00

27007 ditto but 2280 LPM discharge

748930.00

27008 ditto but 2640 LPM discharge

868940.00

27009 ditto but 2850 LPM discharge

901880.00

27010 ditto but 4560 LPM discharge

964450.00

27011 Fire pump electrically driven horizontal


end Suction, centrifugal type confirming
to IS- 12469 :1988 with CI Casing , bronze
impeller and Stainless steel shaft mounted
on heavy duty bearings Suitable for
continuous operation with 'range of
operation' 0 % to 150 % of rated capacity
for 440 V , 3 Phase. 50 Hz 70m Head, 1620

LPM discharge

300440.00

27012 ditto but 2280 LPM discharge

340750.00

27013 ditto but 2640 LPM discharge

501310.00

27014 ditto but 2850 LPM discharge

550210.00

27015 ditto but 4560 LPM discharge

622780.00

27016 All as per item 27011 but 90m Head,


1620 LPM discharge

322280.00

27017 ditto but 2280 LPM discharge

440260.00

27018 ditto but 2640 LPM discharge

576170.00

27019 ditto but 2850 LPM discharge

632060.00

27020 ditto but 4560 LPM discharge

703120.00

SECTION 27

487

SECTION 27 FIRE HYDRANT, FIRE DETECTION AND ALARM SYSTEM


FIRE HYDRANT AND SPRINKLER SYSTEM
EACH SET
27021 Jockey pump horizontal end suction
centrifugal type Confirming to IS- 12469:
1988 with CI casing , bronze impeller and
stainless steel shaft mounted on heavy
duty bearings suitable for automatic
operation with nonover loading power
characteristics for frequent start / stop
operations for 440 V , 3 phase, 50 Hz 70 m

head 180 LPM discharge


27022 All as per 27021 but 90m head 180 LPM

discharge

M&L
Rs.

150470.00
176760.00

27023 Booster pumps for 440 V, 3 Phase, 50 Hz


Confirming to IS- 12469 :1988 With CI
Casing bronze impeller and stainless steel
shaft mounted on heavy duty bearings
suitable for 440 volts, 3 phase, 50 Hz 30m

head, 450 LPM discharge

57000.00

27024 ditto but 900 LPM discharge

108805.00

27025 All as per 27023 but 36m head, 450 LPM

discharge

62910.00

27026 ditto but 900 LPM discharge

123655.00

27027 Motor control centre electrical driven


hydrant / Sprinkler common main &

Jockey Control Panel 60 HP

238890.00

27028 ditto but 90 HP

303420.00

27029 ditto but 110 HP

357200.00

27029 Electrial driven hydrant main, Sprinkler


Standby & Jockey pump control panel. 6 0

HP

268020.00

27030 ditto but 90 HP

378220.00

27031 ditto but 110 HP

437540.00

WATER PIPES
PERRUNNINGMETRE
Bore in mm

27032 MS ERW
PIPE

300

250

200

150

100

80

65

50

40

32

25

3462.90 3161.50 2785.70 1741.50 1204.60 820.00 631.80 518.80 368.30 330.60 255.30

SECTION 27

488

SECTION 27 FIRE HYDRANT, FIRE DETECTION AND ALARM SYSTEM


FIRE HYDRANT AND SPRINKLER SYSTEM
WATER PIPES
Dia in mm

PER RUNNING METRE


27033 GI pipes Heavy

Class

150

100

80

65

50

40

32

Dia in mm

EACH
200

150

100

80

65

50

27034 Sluice Valve Class PN 1.6 22029 14859 11601 9906 8342 5637
13231 10103 8294 5511 3617 2859
27035 Butterfly Valve
27036 Non Return Sluice Valve 21280 12872 7772

6322 5002

4181

13769 10552 8538


27037 Non Return butterfly Valve

5833 3976

3194

Dia in mm
27038 Gate valve

27039 Ball valve

50
6974
6485

25
2297
2046

Dia in mm
27040 Strainer for Suction

25

2052.50 1374.90 951.00 746.30 599.00 443.60 381.40 301.20

200
150
20564 12807

100
7564

M&L
Rs.

EACH SET
27041 Fire brigade inlet connection 2way

10037.50

27042 ditto but 4 way

17109.80

27043 Air Cushion tank with relief valve 200

mm

15888.10

27044 ditto but 300 mm

18805.40

27045 Hydrant valve single headed

9345.80

27046 ditto but double headed

18152.30

27047 C P hose 7.5 m

5524.00

27048 ditto but 15 m

7555.50

27049 RRL hose type - A 7.5 m

5905.10

27050 ditto but 15 m

8205.10

27051 Branch pipe gun metal 63mm


instantaneous inlet, made threaded

outlet, 15mm bore nozzle short

3666.30

27052 ditto but long

6126.90

SECTION 27

489

SECTION 27 FIRE HYDRANT, FIRE DETECTION AND ALARM SYSTEM


FIRE HYDRANT AND SPRINKLER SYSTEM
M&L
Rs.

EACH SET
27053 Hose reel drum 30m

7935.50

27054 ditto but 36m

10729.20

27055 Hose box made of 18 gauge MS Sheet


800mm X 600mm X 250mm with double
door with 4 mm thick glasses and door
frame made of 16 gauge MS sheet painted
fire red out side and brilliant white inside

yard

4986.20

27056 ditto but internal

7397.70

27057 ICV / Alarm gong (Intermittent hydraulic


alarm with alarm gong and water motor

Alarm) 100 mm

51724.60

27058 ditto but 150mm

65927.70

EACH
27059 Sprinkler glass bulb type (Standard
response) as per IS:15106/TAC
guidelines 68 degree temperature rating

pendent type

359.50

27060 ditto but Upright type

359.50

27061 ditto but Side wall

501.30

27062 ditto but Concealed type

1495.90

27063 Sprinkler glass bulb type (Standard


response) as Per IS:15105/TAC
guidelines 79 degree temperature rating

pendent type

384.40

27064 ditto but upright type

384.40

27065 ditto but side wall

581.90

27066 ditto but concealed type

1776.10

27067 Sprinkler quick / early response type as


per IS:15105/TAC guidelines 68 degree

temperature rating

970.50

27068 Ditto but Upright type

1017.30

27069 Sprinkler Quick / Early response type as


per IS 15105/TAC guidelines 79 degree

temperature rating pendant type

970.50

27070 ditto but upright type

1017.30

27071 Sprinkler rossette 25mm dia

162.50

27072 Sprinkler flexible type 1m

1762.20

27073 ditto but 1.5m

2222.50

27074 Puddle Flange 100mm dia

3456.60

27075 ditto but 150mm dia

5522.50

27076 ditto but 200mm dia

7406.60

SECTION 27

490

SECTION 27 FIRE HYDRANT, FIRE DETECTION AND ALARM SYSTEM


FIRE HYDRANT AND SPRINKLER SYSTEM
M&L
Rs.

EACH
27077 Pressure gauge 4"dial 0-14 kgs rating

1065.40

27078 ditto but 4"dial 0-21 kgs rating

1364 30

27079 ditto but 8"dial 0-14 kgs rating

1975.00

27080 ditto but 8"dial 0-21 kgs rating

2819.50

27081 Air vessel 250mm dia 1m height

21369.30

27082 ditto but 300mm dia 1m height

25331.30

27083 ditto but 250mm dia 2m height

23837.60

27084 ditto but 300mm dia 2 m height

28579.10

27085 Yard hydrant Post / Stand Post 80mm


Dia GI / MS both flanged type 1.5m

Height

4124.80

27086 ditto but 2 0 m height

5781.20

27087 Flanged stand post CI of 80mm dia 1.5m

height

7535.30

27088 ditto but 2.0 m height

10133.80

27089 Pressure switch Universal type

3377.90

27090 Flow switch 80mm dia

8496.30

27091 Ditto but 100mm dia

9029.00

27092 ditto but 150mm dia

9717.60

27093 Pipe Support for all types of pipes


including hangars / fastners / elbows/

supports / tees

149.40

FIRE DETECTION AND ALARM SYSTEM


EACH SET

M&L
Rs.

27094 Fire alarm control panel complying with


BS EN 54 Single loop panel of capacity from
99 detectors & 99 modules upto 200 detector

and modules

95496.00

27095 ditto but 2 loop panel with 99 detectors &


99 modules & upto 200 detectors and

modules (per each loop)

113033.00

27096 ditto but 4 loop panel with 99 detectors &


99 modules & upto 200 detectors and

modules (per each loop)

205263.00

27097 ditto but 5 loop panel with 99 detectors &


99 modules & upto 200 detectors and

modules (per each loop)

595615.00

SECTION 27

491

SECTION 27 FIRE HYDRANT, FIRE DETECTION AND ALARM SYSTEM


FIRE HYDRANT AND SPRINKLER SYSTEM
M&L
Rs.

EACH
27098 Detectors Complying with and type
certified to EN - 45 Addressable type
smoke detector Photoelectric /Optical
with base with self built intelligence as

per IS: 11360


27099 ditto but Addressable type multisensor

detector with heat and smoke combination


27100 ditto but Addressable type heat detector with
base with rate of rise cum fixed temperature

as per lS:2175
27101 ditto but Addressable type duct detector
housing with sampling tube( add up cost
of smoke detector as mentioned in
SI. No 27097/27098 additional into this

unit)
27102 ditto but Addressable type Flame detectors
with UV/IR detection capacity( add up cost
of module to be a complete set, the type of

module shall be relay type module)

3910.00
4456.00

3910.00

9485.00

111651.00

BEAM MASTER DETECTOR


27103 Beam Master detector with Transmitter
and receiver (Add power supply units &

Module)

72099.00

27104 Beam Master Detector, Transceiver Type

(Add power supply unit & module)

74437.00

ANNUNCIATING DEVICES
27105 Addressable control module

5281.00

27106 Addressable monitor module

5281.00

27107 Addressable manual call point resettable

type

4969.00

27108 Addressable electronic sounder cum strobe

6762.00

27109 Addressable sounder

5281.00

27110 Loop powerd sounder strobe

6060.00

27111 Loop powerd sounders

5281.00

27112 Short circuit isolators

2709.00

27113 Explosive proof manual call point (Add up

control module)

8087.00

27114 Remote response indicators

144.00

27115 6 Watt ceiling Speaker

1143.00

27116 4 Watt ceiling Speaker

1123.00

27117 6 Watt wall mount CD Speaker

2209.00

27118 10 Watt wall mount CD Speaker

2709.00

PA SYSTEM

SECTION 27

492

SECTION 27 FIRE HYDRANT, FIRE DETECTION AND ALARM SYSTEM


FIRE HYDRANT AND SPRINKLER SYSTEM

M&L
Rs.

EACH
27119 100 Watt Amplifier

31414.00

27120 250 Watt Amplifier

48263.00

27121 500 Watt Amplifier

61058.00

27122 Microphone Set

5456.00

27123 Control Console

36640.00

27124 Fire Alarm Sounders / Sirens Electronic


type horizontal single stage continous
normal operation for atleast 50 minutes
with sound level 65 DB to 120 DB measured
at 1.5 Mtr with sound output variation of +
5 DB
500 mtrs range

8178.00

27125 ditto but 1000 m range

8300.00

27126 ditto but 1500 m range

11884.00

27127 ditto but 2000 m range

12537.00

27128 ditto but 3500 m range

15185.00

27129 Fire Alarm sounders / Sirens electronic


type horizontal two stage continous
normal operation for atleast 50 minutes
with sound level 65 db to 120 db Measured
at 1.5m with sound output Variation of + 5

db 500m range

8794.00

27130 ditto but 1000m range

10484.00

27131 ditto but 1500m range

12907.00

27132 ditto but 3500m range

15705.00

SECTION 28

493

SECTION 28 INCINERATOR
(a)

The rate of incinerator is for the complete job work.

(b)

The rate for incinerator of intermittent capacity


shall be determined by interpolation.
EACH JOB

28001 Supply, install,testing and commissioning


of oil fired incinerator having 10 Kg/Hr
burning capacity horizontal/vertical type
comprising of primary chamber, secondary
chamber, designed on "controlled air"
incineration principle and provided with
minimum of 115mm thick refractory and
insulation bricks conforming to IS 8-1994
and IS 2042-2006 to sustain minimum
temperature of 1000 Degree centigrade in
the primary chamber and 1200 Degree
centrigrade in secondary chamber, one fully
automatic pressure jet type burner for each
chamber, chamber made of mild steel plate
of adequate thickness (minimum 5mm
thick), 30 metre high chimney, exhaust
system, high pressure ventury Scrubber,
PLC based control panel, droplet separator
etc., including all other accessories and
piping, equipments and civil works required
for installation of incinerator chimney
complete all as specified, including
following(a)
Fuel tank suitably fabricated out of mild
steel, provided with connection for supply,
return, drain & vis checking of quantity of
fuel in tank.
(b)
An emergency stack to vent out the gases in
case of power failure.
(c )
Circulation pump, recirculation tank, inter
connection piping, ID fan, FD fan,
instruments, valves, dampers & fittings etc.
(d)
Electrical control panel with all electrical

power, earth & control cabling.

26,48,000

28002 -do- but 20 Kg/hr Capacity.

29,32,000

28003 -do- but 25 Kg/hr Capacity.

31,64,000

28004 -do- but 40 Kg/hr Capacity.

40,28,000

28005 -do- but 50 Kg/hr Capacity.

49,47,000

28006 -do- but 75 Kg/hr Capacity.

51,82,000

28007 -do- but 100 Kg/hr Capacity.

53,47,000

28008 -do- but 150 Kg/hr Capacity.

93,62,000

28009 -do- but 200 Kg/hr Capacity.

1,11,31,000

494

SECTION 29

SECTION 29 RAIN WATER HARVESTING


ROOF COVERING
(a) Items of work required for roof covering,
RCC/Bride underground tank collection
pits, percolation pits, recharge pit/trench/
well shall be measured under respective
section of SSR Part II herein before and
preambles and notes given hereunder shall
be equally applicable for such items of work.
(b) Excavation and earthwork required for laying
of pipes & underground PVC storage tank
shall be measured separately.
(c) The measurement of pipes shall be net as fixed
between the fittings including short lenghts,
without any allowance for cutting and waste,
and in case of spigot and socketed pipes for the
protions entering the sockets of the pipes and
fittings. Fittings shall be measured separately.
(d) The rates for laying UPVC and HDPE pipes
and fittings include for jointing and jointing
materials.
Bore in mm

PER RUNNING METRE


UPVC PIPES

50

65

75

100

150

Rs.

Rs.

Rs.

Rs.

Rs.

29001 UPVC Pipes (SCH-40) 143.50 225.70 285.00 410.00 843.40


29002 UPVC Pipes (SCH-80) 172.60 289.70 392.50 545.70 1160.00
HDPE PIPES
29003 HDPE Pipes PN 10

221.50 353.30 495.70 1062.50 2243.80

EACH
BALL VALVES
29004 UPVC Ball Valve

1678.60 3022.90 4790.30 7913.70

FILTER UNIT

Bore in mm
10

20

30

40

50

60

Rs.

Rs.

Rs.

Rs.

Rs.

Rs.

29005 Gravity Flow Filter


Unit complete 6695.00 13395.00 20090.00 26790.00 33485.00 40185.00
STORAGE TANK
Capacity in ltrs
Rates do not
include the cost of
1200
2000
3000
4000
5000
6000
pipes & fittings.
Rs.
Rs.
Rs.
Rs.
Rs.
Rs.
29006 PVC under ground
9815.00 16360.00 24540.00 32720.00 40900.00 49000.00
Tank

495

SECTION 29

SECTION 29 RAIN WATER HARVESTING


COMPOSITE RAIN WATER HARVESTING SYSTEM
The unit rates for Composite Rain water
Harvesting system include of the following
Underground water storage thank of
respective capacity
01 Piece
First flush system
01 Set
Gravity Filer
01 PC
Delivery pipes 25mm size
15 mtr
Down take pipes 100mm size
15 mtr
EACH

Capacity in ltrs
1200

2000

3000

4000

5000

Rs.

Rs.

Rs.

Rs.

Rs.

6000

Rs.
29007 Composite system 34512.00 43576.00 56526.00 61705.00 74653.00 77244.00