You are on page 1of 11

http

//www.cchongda.com.cn

Contents
Note before use....2 Operation for Shepherd 260 European Standard Fingerprint Lock .....3 1. Notes for functional buttons......3 2. Save fingerprint....3 3. Store password....4 4. Delete fingerprint..5 5. Keep unlocking....7 6. Opening the door with fingerprint or password...7 7. Non disturbance....8 8. Checking on users ID number and the remaining space..8 9. Main specification ...9 10. Trouble shooting .....10

If there has any difference between users manual and product, please refer to product.

1 shepherd260 V1.1

http

//www.cchongda.com.cn

Note before use


1. Memory capacity 50 persons 2. Authority management 2 levels .The first 5 persons are administrators, 45 persons are users. Only administrators can store and delete users fingerprints and have password authority. 3. Alarm for bar proof condition The lock will alarm under the bar proof unlocking condition with continuous beeps. To stop the alarm, please take off the battery. 4. LED Display Users ID: 01~50 Empty user :UU Fingerprint memory space :50~00 Full users: FU

5. Low battery prompt While opening the door, 6 beeps indicate the battery is low. Need to replace batteries. The lock still can use about 50 times above.

2 shepherd260 V1.1

http

//www.cchongda.com.cn

Operation for Shepherd 260 European Standard Fingerprint Lock


1. Notes for functional buttons
Scanning window Indicator Slide cover Power on button LED Display Cycle button Delete button Save button Battery Cover

Handle

Handle Inside unit Inside knob

Override key hole Outside unit

Password input keyboard

2. Save fingerprint
(1) Save administrators fingerprint (01~50)

Press power on button.

Long press SAVE button and hear beep, LED displays 01. Long press again to store the fingerprint. 3

Put fingerprint on the scanning window for 3 times scanning. Once success, hearing 2 prompt beeps, LED displays 02. V1.1

shepherd260

http

//www.cchongda.com.cn

After every administrator store fingerprint successfully, the lock will power off .The administrator must verify fingerprint, then go to the next step. (2) Save users fingerprints (06~50)

Press power on button, the administrator verify the fingerprint or password successfully.

Long press Save button .LED displays the available ID number. Press button to select ID number.

Long press SAVE button to store users fingerprint (the same as above for administrator ) .

If not power off, you can continuously store users fingerprints until memory is full (LED displays FU)

3. Store password (4~12 digits password)

Press power on button, the administrator verify the fingerprint successfully.

Long press save button, LED display password number. Sliding over the cover, again long press save button until hearing prompt beep, indicate to input password. 4

After inputting the password, press ENTER button to confirm.

shepherd260

V1.1

http

//www.cchongda.com.cn

While inputting password, if need to modify password, press CLR button to wait LED displays 00 , then input again. If the password inputting less than 4 digits ,press ENTER button .If over than 12 digits, it will prompt beep to indicate error operation.

4. Delete fingerprint
(1) Delete users fingerprints one by one (50~06)

Press power on button, the administrators or password verify fingerprint successfully.

Long press Delete button, LED display ID Number .Press button to select the user to be deleted.

Long press DELETE button. Hearing prompt beep, i.e. deletion is successful.

(2) Delete all of the saved fingerprints quickly(01~50)

Press power on button, the administrators fingerprint or password verify successfully. 5 shepherd260

Press STORE and DELETE button at the same time. Hearing prompt beep, LED displays UU , i.e. deletion is successful.

V1.1

http

//www.cchongda.com.cn

(3) Replace administrators fingerprint You can only replace the administrations fingerprint or password, but cant delete it, while there have fingerprint or password in the lock.

Press power on button, the administrator verify the fingerprint .

Press DELETE button, hearing prompt beep to indicate storing replacer s fingerprint.

After replaced fingerprint , hearing prompt beep, i.e. replacing is successful.

(4) Forcedly delete administrator s fingerprint The administrators fingerprint can be deleted directly without verification, but there should no users fingerprint in the memory.

Press DELETE button and hold. Press power on button, hearing prompt beep, then remove DELETE button.

LED displays UU , i.e. deletion is successful.

6 shepherd260 V1.1

http

//www.cchongda.com.cn

5. Keep unlocking
Set up The user verifies the fingerprint or password successfully to unlock the door. Press power on button, blue light twinkle to show unlocking. Release Press power on button again, green light twinkle 2 times, the function will be automatically released. The door is locked.

6. Open the door with fingerprint or password


Open the door with saved fingerprint Open the door with saved password

Press power on button.

the Putting saved fingerprint on the scanning window to verify, 2 prompt beep indicate the door is open.

Sliding over the cover to power on, hearing a prompt beep, then input password.

After finish it, press ENTER button, hearing a prompt beep, then open the lock.

7 shepherd260 V1.1

http

//www.cchongda.com.cn

7. Non disturbance
Set up Release

Turning the indoor knob to RED position.

Turning the indoor handle to Green position.

8. Checking on users ID number and the remaining space


Check on users ID number Check on the remaining space

Unlocking the door, press button to check the users ID number.

button to Press check the remaining space.

8 shepherd260 V1.1

http

//www.cchongda.com.cn

9. Main specifications

Specifications
1. Size of fingerprint scanning >18mmx22mm

window: 2. Fingerprint sensor: 3. Fingerprint scanning time: 4. Fingerprint recognition time: 5. Fingerprint registration times: 6. False Acceptance Rate (FAR): 7. False Rejection Rate (FRR): 8. Fingerprint translation tolerance: 9. Fingerprint rotation tolerance: 10. Fingerprint capacity: 11. System power supply: 12. Battery life-span: 13. Working environment

Optical
0.2 second 1.2 second

3 times
0.0001% 0.1% 5mm 180

50 persons
4 pieces of 5 AA alkaline cells

support over 8000 cycle operations 18~55

temperature: 14. Working environment humidity: 099%

The product specifications


15. Dimensions (mm) : Outside unit:290 x 60 x38 Inside unit: 290 x 64 x 31 16. Weight : 17. Suitable door thickness:

2.5kg 35mm~50mm
9

shepherd260

V1.1

http

//www.cchongda.com.cn

10. Troubleshooting
Possible Cause 1. LED do not have any display or display improper 2. After installed batteries, press power on button, the system have no any feedback 3. After installed batteries, press power on button, the red lamp flash two times and then the system have no any feedback Solution Please check the connecting cable. 1. Please check the batteries direction. 2. Please check the connecting cable.

Please check the lock knob.

4. After install finished, turn the handle, the handle do not come back automatically

It is the installation problem for lockset. There has warp for the holes of handle spindle and the holes of installation. Please follow the cutout template sheet, reconfirm the location of the holes. Low Voltage batteries. alarm, Replace

5. When power on,6 alert beeps are heard 6. After install finished, the system show unlock successfully, but turn the handle, the door do not open.

When install, the handle spindle did not insert the hole of outside unit .Please turn the handle and check if it can drive handle spindle running and then install inside unit . In order to fit different door thickness, we prepare two kinds of screws. If the door thickness less than 40mm, please choose the shorter four screws. The only way to unlock the lock knob is turn inside unit handle. When install the battery, put the ribbon on the bottom for easy take battery off.

7. when install, the four screws can not installed in the bottom

8. If the lock knob setup to lock, no way to cancel the handle 9. After installed batteries, ribbon is out of battery cover

10 shepherd260 V1.1

http 10. After installing outside unit, the lock body can not close to door surface 11. After the door opening successful, close the door again, the system can not power off automatically. 12. After install, close the door, the latch can not hold out 13. Using the override key to open the lock, the latch can not hold out

//www.cchongda.com.cn

When install, please do not tighten the screws. While the lock head move freely, then install outside unit. Please check the connecting cable for lockset. Readjust the depth of strike. The distance between lock and strike should less than 4mm. After open lock with override key, it needs to turn normal place and take off.

11 shepherd260 V1.1