Roof
Fibran Eco RF / 60
Extruded polystyrene foam boards are used for the insulation of: attics terraces f loors inverted roofs basement walls
Available edge profiles : I/L/D
XPS-EN13164-T1-CS(10/Y)***-MU100-WL(T)0,7-WD(V)3-DS(TH) Thickness: Board dimensions: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 20-3040506080100120 mm 1250 x 600 mm 0.7 % 100 D = 0.033 W / m*K ( 30mm) D = 0.036 W / m*K (> 30mm- 50mm) D = 0.038 W / m*K (> 50mm) ***Thickness CS(10/Y) : 20mm 200 kPa > 20mm- 40mm 250 kPa > 40mm 300 kPa
Roof
Fibran Eco WL / 60
Extruded polystyrene foam board used for the insulation of: external cavity walls
Available edge profiles : I/L/D
XPS-EN13164-T1-CS(10/Y)***-MU80-WD(V)3-DS(TH) Thickness: Board dimensions: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 253040506080100 mm 2500 x 600 mm 3% 80 D = 0.033 W / m*K ( 30mm) D = 0.036 W / m*K (> 30mm- 50mm) D = 0.038 W / m*K (> 50mm)
1 of 7
3/10/2012 8:44
Fibran ECO
http://www.dincergroup.com/fibraneco.htm
Thickness CS(10/Y) :
30mm 100 kPa > 30mm- 40mm 200 kPa > 40mm- 60mm 250 kPa > 60mm 300 kPa
Rough
Fibran Eco BT / 60
Extruded polystyrene boards are used for the insulation of: structural frame of reinforced concrete wherever the perfect adherence on the concrete or mortar is needed
Available edge profiles : I/L/D
XPS-EN13164-T3-CS(10/Y)***-MU50-WL(T)1,5-DS(TH)-TR400** Thickness: Board dimensions: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 253040**50**60**80100 mm 2500 x 600 mm 1.5% per volume 50 D = 0.033 W / m*K ( 30mm) D = 0.036 W / m*K (> 30mm- 50mm) D = 0.038 W / m*K (> 50mm) ***Thickness CS(10/Y) : 30mm 100 kPa > 30mm- 60mm 200 kPa > 60mm 300 kPa
Gofre
Fibran Eco GF / 60
Extruded polystyrene boards are used for : general application
Available edge profiles : I/L/D
2 of 7
3/10/2012 8:44
Fibran ECO
http://www.dincergroup.com/fibraneco.htm
XPS-EN13164-T1-CS(10/Y)***-MU50-WL(T)0,7**-DS(TH) Thickness: Board dimensions: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 2030**40**50**60**80100 mm 2500 x 600 mm 0.7% per volume 50 D = 0.033 W / m*K ( 30mm) D = 0.036 W / m*K (> 30mm- 50mm) D = 0.038 W / m*K (> 50mm) ***Thickness CS(10/Y) : 20mm 200 kPa > 20mm- 40mm 250 kPa > 40mm 300 kPa
Giga
Fibran Eco GI /120 / I
Extruded polystyrene boards are used for the insulation of: big surfaces industrial buildings false ceilings
Available edge profiles : I/L
XPS-EN13164-T1-CS(10/Y)***-MU100-WL(T)0,7-WD(V)3-DS(TH) Thickness: Board dimensions: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 253040506070 mm 2500 x 1200 mm 0.7 % per volume 100 D = 0.033 W / m*K ( 30mm) D = 0.036 W / m*K (> 30mm- 50mm) D = 0.038 W / m*K (> 50mm) ***Thickness CS(10/Y) : 20mm 200 kPa > 20mm- 40mm 250 kPa > 40mm 300 kPa
3 of 7
3/10/2012 8:44
Fibran ECO
http://www.dincergroup.com/fibraneco.htm
Floor
Fibran Eco FL / 60
Extruded polystyrene boards are used for the insulation of f loors where the heavy loading resistance requirements exists
Available edge profiles : I/L/D
XPS-EN13164-T1-CS(10/Y)400-MU50-WL(T)0,7-WD(V)3-DS(TH) Thickness: Board dimensions: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 305075 mm 1250 x 600 mm 0.7 % per volume 50 D = 0.033 W / m*K ( 30mm) D = 0.036 W / m*K (> 30mm- 50mm) D = 0.038 W / m*K (> 50mm) ***Thickness CS(10/Y) : 30-75 mm 400 kPa
Cool Rooms
Fibran Eco FR / 60
Extruded polystyrene boards Fibran Eco FR/60 are used for insulation of cold stores
Available edge profiles : I/L/D
XPS-EN13164-T1-CS(10/Y)***-MU50-WD(V)3-DS(TH) Thickness: Board dimensions: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 5075100 mm 1250 x 600 mm 3 % per volume 50 D = 0.033 W / m*K ( 30mm) D = 0.036 W / m*K (> 30mm- 50mm) D = 0.038 W / m*K (> 50mm) ***Thickness CS(10/Y) : 30-75 mm 400 kPa > 50 mm 500 kPa
4 of 7
3/10/2012 8:44
Fibran ECO
http://www.dincergroup.com/fibraneco.htm
Planed
Fibran Eco PL
Extruded polystyrene boards are used for the insulation of: structural frame of reinforced concrete wherever the perfect adherence on the concrete or mortar is needed
Available edge profiles : I/L/D
XPS-EN13164-T3-CS(10/Y)***-MU50-WL(T)1,5-DS(TH)-TR400** Thickness: Board dimensions: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 25 30 40** 50** 60** 80 100 mm 1250 x 600 mm - 2500 x 600 mm 1.5 % per volume 50 D = 0.033 W / m*K ( 30mm) D = 0.036 W / m*K (> 30mm- 50mm) D = 0.038 W / m*K (> 50mm) ***Thickness CS(10/Y) : 30mm 100 kPa > 30mm- 60mm 200 kPa > 60mm 300 kPa
Pilotis
Fibran Eco PI / 120 / I
Extruded polystyrene boards are used for the insulation under the reinforced concrete blocks
Available edge profiles : I
FibranEco PI/120/I Pilotis Boards Density (min): Thickness: Board dimensions: 3 = 32 kg / m 42.5 52.5 62.5 mm 2500 x 1200 mm
5 of 7
3/10/2012 8:44
Fibran ECO
http://www.dincergroup.com/fibraneco.htm
Compression strength at 10% deformation: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 0.7 % per volume 50 D = 0.032 W / m*K
Wall Facing
Fibran Eco PI / 120 / I
Extruded polystyrene boards are used for the insulation of: walls externally concrete elements
Available edge profiles : I
FibranEco PI/120/I Pilotis Boards Density (min): Thickness: Board dimensions: Compression strength at 10% deformation: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 0.7 % per volume 50 D = 0.032 W / m*K 3 = 32 kg / m 39.5 49.5 59.5 mm 2500 x 1200 mm
Wall Facing
Fibran Eco GP / 120 / I
Extruded polystyrene boards are used for the insulation of: walls externally concrete elements
Available edge profiles : I
FibranEco GP/120/I Wall Facing Boards Density (min): Thickness: Board dimensions: 3 = 32 kg / m 39.5 49.5 59.5 mm 2500 x 1200 mm
6 of 7
3/10/2012 8:44
Fibran ECO
http://www.dincergroup.com/fibraneco.htm
Compression strength at 10% deformation: Water absorption by immersion: Water Vapor Transmission : Thermal Conductivity : 0.7 % per volume 50 D = 0.032 W / m*K
7 of 7
3/10/2012 8:44