You are on page 1of 58

Site Information

HCPT Site ID

Site Name

Site NSN

Site Huawei

Subcon

Region

2 132198 130540 Nurama Gumelar XL Tanggul Wetan

Site Information

Plan Date

Actual Date

Week Number

Activity-ID (Push Pull Aplication)

Site Type

Subcon PIC

2 11-Oct-12 13-Oct-12

100

2 End Site End Site

2 Herry Wahyono Herry Wahyono

41 41

Not Responding 20121013-UWQP

MCB PLN Capacity

MCB PLN Capacity (OK/NOK/NA)

PLN Input Voltage RN

PLN Input Voltage RN (OK/NOK/NA)

PLN Input Voltage SN

PLN Input Voltage SN (OK/NOK/NA)

PLN Input Voltage TN

2 3x10A 3x10A

2 OK OK

2 216 210

98 OK OK

2 219 198

98 OK OK

2 218 218

CME

PLN Input Voltage TN (OK/NOK/NA)

PLN Input Voltage RS

PLN Input Voltage RS (OK/NOK/NA)

PLN Input Voltage RT

PLN Input Voltage RT (OK/NOK/NA)

PLN Input Voltage ST

PLN Input Voltage ST (OK/NOK/NA)

98 OK OK

2 380 359

98 OK OK

2 375 361

98 OK OK

2 379 364

98 OK OK

PLN Input Voltage GN

PLN Input Voltage GN (OK/NOK/NA)

Arrester

Grounding

OBL

Yard lamp

Air Cond

2 0.5 3.3

98 OK NOK

2 OK OK

2 OK OK

2 OK OK

2 OK OK

2 N/A N/A

Rectifier

Shelter

Type Rectifier

Number of ACDC Modul/PSU Installed

DC Output

DC Load

DC Load (OK/NOK)

2 N/A N/A Delta (30A) Powerware

2 3x30A 3x30A

2 53 53.97

2 11.05 15

2 OK OK

Rectifier

Temperatu re

Any Alarm in ACDC/PSU ?

Arrester Condition

Filter Cleanliness Condition

FAN Cleanliness and Function Condition

Indoor Cabinet cleannes and door condition

2 38 39

2 OK OK

2 OK OK

2 OK OK

2 OK OK

2 OK OK

Battery System

Battery Type

Number of Battery Bank Installed

Number of Battery Bank Installed (OK/NOK)

Batery Voltage

Backup Time, Batt cap/ Load (Hours)

Test 1 Hour

2 Narada 12V_100Ah Sonnenchen 12V_130Ah

2 1 1

2 OK OK

2 48 51

2 2 4

2 OK OK

Cleanliness Battery

VSWR BTS

VSWR Node B

Configurasi BTS

BSC

PCMB

BTSM#/ BCF ID

2 OK OK

2 OK OK

2 N/A N/A

2 1/1/2 2/2/2

2 JMBR JMBR

2 33 10

2 258 64

BTS /NODE -B

Timeslot

ABIS Config

BTS Type

Feeder Type

Antenna Type

Antenna Height (0/1/2)

2 30 30

2 Multidrop Multidrop

2 BS-241 BS-241

2 Draka 1 1/4" Draka 1 1/4"

2 Cross Polar Cross Polar

2 40/40/40 40/40/40

BTS /NODE -B

Antenna Azimuth (0/1/2)

Configurasi Node B

Installation Feeder & Grounding & Grounding Waterprofing ( Kit ( Waterprofing & Rubering & Insolation Conector Rubering ) Outdoor )

Label Feeder & Jumper

2 60/215/315 115/205/295

2 N/A N/A

2 OK OK

2 OK OK

2 OK OK

BTS/Node B Performance (Check Modul & Temperature Rack instalation Wiring / Faulty)

Filter Cleanliness Condition

FAN Cleanliness and Function Condition

indoor Cabinet cleannes such as free from insect and door condition such as door lock 2 OK OK

Test Call

2 OK OK

2 OK OK

2 OK OK

2 OK OK

2 OK OK

Test Enva

IDU ODU , Grounding Kit & Installation, Outdoor Instalation & Grounding ODU WaterProfing ( (ODU, CoaxialCable) Performanc & Label Rubering & Insolation ) e

Cable DDF Installation

Farend site

2 OK OK

2 OK OK

2 OK OK

2 OK OK

2 OK OK

2 OK OK

2 131511 130180

Transmision ( Microwav

Azimuth to Farend

Diameter Antenna (m)

Antenna Height

Radio Type

Near End IP Address

Far End IP Address

2 60 125

2 0.6 0.6

2 31 33

2 SRAL-XD SB2 SRAL-XD SB2

2 10.51.100.5 10.253.165.3

2 10.255.179.5 10.188.122.21

Transmision ( Microwave )

Capacity E1

Transmitter (TX) Frequecy

Receiver (Rx) Frequency

ODU Type

Power

Configurasi

RSL NE (main, stndb)

2 4 E1 4 E1

2 14651.5 7233

2 15141.5 7394

2 15_506 07_132

2 18 23

2 1+0 1+0

2 -40 -37

Reset SV card RSL NE RSL FE (main, RSL FE (main, Dehidrator Presure (SRT1F (main, stndb) stndb) stndb) (SRT-1F Only) only/coordinate with OK/NOK OK/NOK BO NSN)

IDU & DDF Label

Q-V Lan, Serial cable

2 OK OK

2 -39 -38

2 OK OK

2 N/A N/A

2 N/A N/A

2 OK OK

2 N/A N/A

Aceess Issues

Key Issues

NetViewer visibility ?

Site Depedencies

Office Hours

Limited Access

Community Issue

Key Fence/Code Padlock

2 NOK OK

2 0 0

2 OK OK

2 OK OK

2 OK OK

2 N/A N/A

Key Issues

Remark/Descript

Key Shelter

Key KWH

Key ACPDB

Key BOX Control

TE Stolen Issues

2 N/A N/A

2 OK OK

2 OK OK

2 N/A N/A

Remark/Description

Genset

CME Stolen Issues

Access Issues

Genset Type

Genset Capasity

2 Door Rack BTS Brokent ; Recti fail 1 pcs ; Recti fail 1 OK OK

2 N/A N/A

2 N/A N/A

Genset

Hidrogen Spiro

CDC

ATS

Fuel %

Spiro capacity

Fuel %

CDC Capacity

Fuel %

2 N/A N/A

2 N/A N/A

2 N/A N/A

2 N/A N/A

2 N/A N/A

2 N/A N/A