Professional Documents
Culture Documents
: Date: 1
10/17/2012
1 Input data
Anchor type and diameter: Effective embedment depth: Material: Evaluation Service Report:: Issued I Valid: Proof: Stand-off installation: Anchor plate: Profile: Base material: Installation: Reinforcement: Seismic loads (cat. C, D, E, or F) Geometry [in.] & Loading [lb, in.lb] HIT-RE 500-SD + HAS B7 1 1/4 hef,act = 12.000 in. (hef,limit = - in.) ASTM A 193 Grade B7 ESR 2322 4/1/2010 | 4/1/2012 design method ACI 318 / AC308 eb = 0.000 in. (no stand-off); t = 2.000 in. lx x ly x t = 70.000 in. x 24.000 in. x 2.000 in.; (Recommended plate thickness: not calculated) W shape (AISC); (L x W x T x FT) = 14.800 in. x 15.500 in. x 0.680 in. x 1.090 in. uncracked concrete, 3000, fc' = 3000 psi; h = 24.000 in., Temp. short/long: 162/110 F hammer drilled hole, installation condition: dry tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar no
3 Warnings
Please consider all details and hints/warnings given in the detailed report!
Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date: 2
10/17/2012
Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan