You are on page 1of 28

LGC in-building systems presentation

Erik Nilsson Director of Sales, Wireless Group, Europe

8/11/2009

LGC Wireless

ADC Coverage & Capacity Solutions


Network Edge; In-building, Near-building, Outdoor

8/11/2009

LGC Wireless

Network Solutions Wireless Portfolio


In-building Solutions InMobility Solutions

nanoBTS LGC Wireless Fusion

microBTS

UltraWAVE Base Station Solutions

FlexWave Base Station Solutions

Outdoor Solutions

Backhaul Solutions

ClearGain GMA FlexWave WMX LoopStar

FlexWave Prism

ClearGain Dual Inline TMA

FlexWave MMW

8/11/2009

LGC Wireless

LGC Company Facts


2002 Winter Games, Salt Lake City, UT

LGC Wireless Inc. - formed 1996 Part of ADC since Dec 2007 Market leader in in-building coverage and capacity solutions
Solutions for small sites up to the largest venues Supports all European and American standards including 802.11
Petronas Towers, Kuala Lumpur

Installed worldwide, with over 10 000 systems shipped to over 40 countries Innovative, patented technology (12 patents issued; 3 pending) ISO 9001/14001 approved Headquarters in San Jos, California Number of employees: 230 (LGC) 9.000 (ADC)

Venetian Hotel, Las Vegas NV

8/11/2009

LGC Wireless

Installation Examples
Sports Venues Airports
Heathrow Atlanta Denver Orlando Sanford JFK

Winter Olympics Salt Lake City, UT SAFECO Field Seattle, WA Manchester United Stadium London, UK

Enterprises Hotels
Venetian Hotel/Casino Las Vegas, NV MGM/Mirage properties Las Vegas, NV Petronas Towers Kuala Lumpur Intel Multiple Sites Google Silicon Valley

Public Facilities

Bullring Birmingham, UK Times Square Kuala Lumpur, Malaysia Anaheim Convention Center Anaheim, CA
LGC Wireless

Santiago Metro Santiago, Chile Mexico City Metro Mexico Sofia Subway Sofia, Bulgaria

Subways

8/11/2009

Deployments worldwide
Corporate
ABN AMRO Aegon Group Albertsons Headquarters American Airlines Headquarters American Express Bank of America Barclaycard Best Buy Headquarters Boeing California State Capitol Dell Computer eBay Federal Communications Commission Florida State Building Frito Lay Genentech General Electric General Motors Google Hewlett Packard IBM Intel JP Morgan Lockheed McGraw Hill Nvidia Phileo Damansara Pixar Systems United Parcel Service Walmart Headquarters Xerox 8/11/2009

Financial
Aegon Group American Express American International Group Bank of America Barclays BBVA Charles Schwab Citibank Daehan Life Insurance Desert Schools Credit Union Fidelity Investments Fidelity National Fireman's Fund First National Bank Fremont Investment and Loan Groupama Insurance HSBC Bank Huntington Bank ING Bank JP Morgan Lehman Brothers London Stock Exchange Merrill Lynch Prudential UBS Union Bank Unum Provident USAA Insurance Visa WestLB

High Tech
3Com Alcoa AMD Anheuser-Busch Apple Computer BellSouth Boeing Cingular Wireless DaimlerChrysler Dell Computer Dr Pepper/Seven Up E&J Gallo Winery eBay Flextronics Ford Motors General Motors Google Hewlett-Packard Honeywell Hummer IBM International Paper Iomega KLA Tencor Kraft Lockheed Martin Medtronics Mercury Interactive Microsoft Miller Brewing Motorola

Hospitals
Alexian Brothers Hospital Baptist Health Borgess Medical Central Baptist Hospital Childrens Hospital Clinton Memorial Hospital Crawford Long Hospital Driscoll Childrens Hospital Enloe Hospital Florida Hospital Forbes Regional Hospital Halifax Medical Center IASO Hospital Indiana Methodist Hospital Johns Hopkins Lakeside Hospital Lima Memorial Hospital Methodist Hospital Orange Park Medical Orlando Regional Hospital Shands Sutter Gould Health University of Arkansas Medical Sciences University of Michigan Health Center Valley Baptist Medical Center Westmoreland Regional Hospital

LGC Wireless

Why Indoor Mobile Coverage?

8/11/2009

LGC Wireless

Drivers for in-building coverage

Increased mobile traffic and usage, driven by:


More capable devices Reduced traffic prices/flat rates Increased acceptance for mobile office solutions Improvements in battery life and network quality Fixed phone replacements

Increased and urgent need for high speed wireless data service The increased need for in-building coverage reduces available time for design and installation Increased quality expectations and shorter time calls for new technologies in in-building solutions

8/11/2009

LGC Wireless

The in-building challenge: RF performance

Isolation, interference Users receives signals from many base stations Metallic coated windows attenu-ating the signal The result is bad quality
In high rise buildings, interfeerence from distant bastations is a problem

The solution is to have a dominant signal

8/11/2009

LGC Wireless

The in-building Challenge: Capacity


Buildings need dedicated capacity Mobile service is crucial inside buildings Dedicated capacity is needed inside big buildings No impact from outdoor traffic congestion

Outdoor traffic congestions must not affect the indoor users


8/11/2009 LGC Wireless

Mobile service should always be available


10

The in-building Challenge: Elevators


Full mobile service is crucial Elevators need full coverage The steel enclosure of the elevator stops the mobile coverage Hard with traditional systems The ADC-Fusion system can be a part of the elevator installation 300m+ elevators

ADC covers the elevators in the ICC in Hongkong


8/11/2009 LGC Wireless 11

Why use active in-building systems?


High and wide buildings can generate high losses in a passive system Historical buildings can be sensitive to extensive drilling and pulling of thick cables Campus applications like universities, amusement parks, sports arenas have buildings that are separated For buildings with restricted access like hospitals, hotels, tunnels, airports When upgrading low frequency systems (like GSM900) to UMTS
UMTS is uplink limited and very sensitive to high losses in a large passive network Historical buildings where drilling is not allowed

For very tall, wide or complex buildings

For high data rate applications based on HSDPA and especially HSUPA

Campus applications

8/11/2009

LGC Wireless

12

ADC In-building Coverage Solutions


ADC In-building solutions:
Superior wireless signal clarity, capacity and coverage Simple standard LAN-type cabling Star or double star architecture

Unison For larger in-building venues, such as corporate campuses and hospitals, requiring single operator support. Unison Accel offers the same performance in a single eightport hub for small venues.
Unison

Fusion For larger in-building venues requiring multi-band or multi-operator support, such as airports, convention centers, and corporate HQs. Fusion SingleStar offers the same performance in a single eight-port hub for small venues.
8/11/2009 LGC Wireless

Fusion

Fusion SingleStar

13

InterReach Unison
Product Overview

8/11/2009

LGC Wireless

14

The Unison Product Family

Unison For larger in-building venues, such as airports, convention centers, and corporate campuses Distribution with Fiber and Cat-5/6 Up to 32 remotes per hub

Unison Accel For small to medium size buildings like offices and hotels Distribution with Cat-5/6 only Up to 8 remotes per hub


8/11/2009

LGC Wireless

15

InterReach Unison Product Line


Unison Accel
Ideal for venues up to 350,000 sq. ft. Max 1-8 configuration

Unison
Large venue solution Max 1-4-32 configuration

Unison Remote Access Units


GSM 900 GSM 1800 UMTS

8/11/2009

LGC Wireless

16

WLAN can be installed in parallel with Unison for considerable cost savings

IT managers often prefer parallel DAS/802.11 systems because they can:


Choose the latest technology (802.11b, a, g, ) Select their 802.11 vendor of choice (e.g. Cisco, Extreme Networks, etc.) Determine the optimal antenna placement for each system (can trade off equipment cost vs. installation cost) Own, manage, and extend the 802.11 system themselves Have a future-proof solution as 802.11 technologies evolve
LGC Wireless 17

8/11/2009

Remote Unit (RAU)


*Max composite power P1dB = 26.0 dBm IP3 = 36 dBm UMTS IP3 = 38 dBm DCS/GSM

RAU Characteristics: Install above ceiling, near antenna NO POWER REQUIRED - Self powered from CAT5 cable Size (H x W x L): 44 x 205 x 158 mm RJ45 connector, SMA port Dust cover
# Carriers UMTS Power [dBm] # Carriers

DCS 1800 Power [dBm] GSM


1 2 3 4 5 6 1 2 3 4 5 6 7 15.0 11.0 8.0 6.5 5.0 4.0 3.0 7 8 9 10 11 12 13 14 15 16 17,5 26.0* 14,5 20.0* 12,5 16.5* 11,5 14.0* 10,5 12.0* 9,5 11.0* 9,0 10.0* 8,5 9.0* 8,0 8.5* 7,5 8.0* 7,0 7.5* 6,5 7.0* 6,5 6.5* 6,0 6.5* 5,5 6.0* 5,5 5.5*

EDGE
23.0* 17.5* 14.0* 12.0* 10.5* 9.5* 9.0* 8.0* 7.5* 7.0* 6.5* 6.0* 6.0* 5.5* 5.0* 5.0*

8/11/2009

LGC Wireless

18

Accel provides best-in-class configuration, monitoring, and alarming capabilities


Extensive system alarming, enabling isolation to the Field Replaceable Unit Easy-to-use installation process Remote configuration, monitoring, and diagnostics Options:
External alarms Connect the Accel system to the BTS external alarm input AdminManager Local or remote control of a single system (hub) Network Interface Unit Offers SNMP interfacing to network vendors O&M system
NIU (Network Interface Unit) AdminManager

8/11/2009

LGC Wireless

19

Introducing

InterReach Fusion

8/11/2009

LGC Wireless

20

InterReach Fusion Product Line


Fusion SingleStar
Ideal for venues up to 350,000 sq. ft. Max 1-8 configuration Available now with 850/1900, 900/2100, and 900/1800 RAU

Fusion large system


Large venue solution Max 1-4-32 configuration Generally available Q4 06

Fusion Remote Access Units


Common to both systems
850/1900 800/900/1900 900/2100 900/1800

8/11/2009

LGC Wireless

21

InterReach Fusion System Components

Hub, RAU, Cabling, Antenna

Remote Access Unit

Expansion Hub

Main Hub

Hub and RAU Dimensions


F-connector with Thin-Ethernet type cabling 0-275 meters distance to RAU Hubs: 19 rack mount, 2U high, 15 deep RAU: ~11.25 x 11 x 2, N connector to antenna

8/11/2009

LGC Wireless

22

Fusion Hubs
Main Hub 2-3 separate RF source inputs* Supports up to 4 E-Hubs RJ45 port for maintenance DB9 for alarm contact support Expansion Hub Supports up to 8 RAUs RJ45 port for maintenance DB9 for alarm contact support

* Based on RAU selected

8/11/2009

LGC Wireless

23

Fusion SingleStar System Components

Hub, RAU, Cabling, Antenna

Remote Access Unit

Hub and RAU Dimensions


Hubs: 19 rack mount, 3U high, 15 deep F-connector with Thin-Ethernet type cabling 0-275 meters distance to RAU
8/11/2009

RAU: ~11.25 x 11 x 2, N connector to antenna

LGC Wireless

24

Fusion Uses CATV Cable to the RAU


CATV cabling is economical, easy to install and connectorize, and provides great reach
Cable types and max run lengths Copper clad Copper core
M ax. length M ax length 150m/490 ft. 170m/560 ft. 275m/900 ft.

RG-59 (.207OD) RG-6 (.237OD) RG-11 (.347OD)

RG 59 RG 6 RG 11

100m/330 ft. 130m/425 ft. 275m/900 ft.

Can use any of 3 CATV cable types RG59, RG6, RG11 Copper clad or copper core Non-plenum or plenum Can mix and match cable types on a single hub
8/11/2009 LGC Wireless 25

Fusion: Best-In-Class Admin & Maintenance


Fusion provides best-in-class configuration, monitoring, and alarming capabilities
Extensive system alarming, enabling fault isolation to the Field Replaceable Unit Easy-to-use installation process Remote configuration, monitoring, and diagnostics Integrated SNMP capabilities optional feature

8/11/2009

LGC Wireless

26

LGC Wireless: The In-Building Wireless Leader


Largest installed base of in-building wireless systems :
Market leader for in-building coverage and capacity solutions since 1996 Over 10,000 systems shipped to more than 40 countries 20 major service provider customers (single operator and neutral host implementations)

Innovative, patented technology (12 patents issued; 3 pending) Extensive design, implementation, and support capabilities
Experienced in-house RF engineers and project managers Global network of service delivery partners

8/11/2009

LGC Wireless

27

Thank you

LGC Wireless, Inc.


Expanding the Reach of Wireless
2540 Junction Avenue San Jose, CA 95134-1902 USA 1 + 408.952.2400
www.lgcwireless.com

8/11/2009

LGC Wireless

28

You might also like