Quiet operation
IP54 motor
Insulation Class F
Easy to install
Mains water inlet size via dual check value BSP (F)
Voltage: 1 x 240 V, 50 Hz
Quiet operation
IP54 motor
Insulation Class F
Quiet operation
Quiet operation
IP54 motor
Insulation Class B
Voltage: 1 x 240 V, 50 Hz
The MQ booster pumps
integrated control unit
automatically protects against:
- dry running
- motor overheating
- motor overload
Dimensions in mm
FEATURES
CONSTRUCTION
APPLICATIONS
TECHNICAL FEATURES
DIMENSIONS / INSTALLATION
GRUNDFOS MQ
Pumps
P2 In (A) Water Connections Weight
(W) temp (C) inlet outlet (kg)
MQ3-35 550 4.0 0/35 1M 1M 13
MQ3-45 670 4.5 0/35 1M 1M 13
PERFORMANCE
Discharge Pressure (kPa/psi)
150 200 250 300 350 400
22 29 36 44 51 58
Pumps Output (l/min)
MQ3-35 61 50 39 24 - -
MQ3-45 66 58 49 39 27 13
As a guide J Lap = J0 liLres per minuLe J sprinkler = JS liLres per minuLe
2
Y
E
A
R
W
A
R
R
A
N
T
Y
In the event of a fault, the MQ
stops automatically, then tries
to restart after half an hour.
15
Easy to install
HOUSEHOLD WATER PRESSURE SYSTEMS
MQ booster pump
1 Pump
2 Suction kit (or 3 strainer valve)
a Isolation valve
1 x 240 V
16
The JP pump is a horizontal, self-priming, centrifugal
pump for pumping clear water and other non-aggressive
liquids.
This compact unit, which can be used in a fixed position
or transported as required, is easy to maintain and is
simple and economical to run.
Carry handle
Voltage: 1 x 240 V, 50 Hz
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5Q [m
3
/h]
0
5
10
15
20
25
30
35
40
45
50
H
[m]
0 10 20 30 40 50 60 70 Q [l/min]
JP
50 Hz
JP 5
JP 6
FEATURES
CONSTRUCTION
APPLICATIONS
Pumps
P2 1 ph Water Connections Weight Dimensions (mm)
(kW) In (A) temp (C) inlet outlet (kg) A B C
JP5 0.48 3.4 0/55 1M 1M 8.5 306 364 240
JP6 0.92 6.2 0/55 1M 1M 11.8 306 401 240
DIMENSIONS / INSTALLATION
GRUNDFOS JP5 / JP6 JET PUMPS
PERFORMANCE
TECHNICAL FEATURES
Discharge
Pressure
(kPa/psi)
Suction Lift (metres)
0 2 4 6
Pumps
Output (l/min)
JP5 L
200/29 52 45 39 33
250/36 38 29 23 16
JP6 L
250/36 72 65 57 48
300/44 53 45 37 31
As a guide J Lap = J0 liLres per minuLe J sprinkler = JS liLres per minuLe
Performance based on zero suction lift
B
2
Y
E
A
R
W
A
R
R
A
N
T
Y
JP5 MP & JP5 / JP6
17
The Hilift 35 is a multi-purpose submersible pressure
pump ideal for rainwater systems, treated grey water
irrigation, operating sprinklers, and pumping water
from tanks.
Voltage: 1 x 240 V, 50 Hz
C
m
a
x
i
m
u
m
GRUNDFOS SPO
The SPO pump is designed for water supply, drainage,
and pressure boosting in domestic homes and
week-end cottages.
Vertical installation
Voltage: 1 x 240 V, 50 Hz
DIMENSIONS / INSTALLATION
Pumps Diameter (mm) Power Dimensions (mm)
Discharge Inlet (connections) (W) H L W
l/min 30 40 45 50 55 60
Sololift+ WC 23/25/28/32 100 400 280 431 190 6.8 6.2 5.8 5.6 5.0 4.8
Sololift+ WC-1 23/25/28/32 100+3x40 400 280 431 190 6.8 6.2 5.8 5.6 5.0 4.8
Sololift+ WC-3 23/25/28/32 100+3x40 400 280 431 190 m Head 6.8 6.2 5.8 5.6 5.0 4.8
Sololift+ CWC-3 23/25/28/32 100+3x40 350 298 476 138 4.8 4.2 3.8 3.4 3.0 2.4
Sololift+ C-3 23/25/28/32 3x40 300 298 476 138 4.4 3.8 3.4 2.8 2.4 1.8
Sololift+ D-3 23/32 1x40+1x40/32 270 144 296 162 4.2 3.6 2.8 2.0 1.4 -
1%
max 10m
max 20m
max 30m
max 50m 1 m
2 m
3 m
4 m
2
Y
E
A
R
W
A
R
R
A
N
T
Y
27
SOLOLIFT+ WC
for single toilet
SOLOLIFT+ WC-1
for toilet and sink
SOLOLIFT+ WC-3
for toilet, sink,
shower & bidet
SOLOLIFT+ CWC-3
for wall hung toilet,
sink and shover
SOLOLIFT+ C-3
for washing machine
& sink
SOLOLIFT+ D-3
for shower and sink
2
3
/
2
5
/
2
8
/
3
2
m
m
SOLOLIFT+ C-3
SOLOLIFT+ D-3
SOLOLIFT+ WC
SOLOLIFT+ WC-1 SOLOLIFT+ WC-3
SOLOLIFT+ WC-3
SOLOLIFT+ CWC-3
m
i
n
.1
4
5
m
m
min.400mm
2
3
/
3
2
m
m
-3
%
-3
%
-3 %
2
3
/
2
5
/
2
8
/
3
2
m
m
m
a
x
.
5
m
-1 %
2
3
/
2
5
/
2
8
/
3
2
m
m
2
3
/
2
5
/
2
8
/
3
2
m
m
m
a
x
. 5
m
-1 %
-3 %
40
m
a
x
. 5
m
-3
%
-1 %
-3 %
2
3
/
2
5
/
2
8
/
3
2
m
m
Sololift+ WC
Sololift+ C-3
Sololift+ CWC-3
Sololift+ D-3
Sololift+ WC-3
Sololift+ WC-1
HOUSEHOLD LIFTING STATION
28
Installation depth: maximum of 10m below the water level.
Unilift CC are multi-purpose submersible drainage pumps
designed to handle clean water, groundwater and grey
wastewater with particles up to 10mm.
It must be completely or partly submerged in the liquid.
Ceramic seal
Semi-open impeller
IP68 motor
Insulation Class F
Compact design
Draining sumps
IP68 motor
Insulation Class F
IP68 motor
Insulation Class F
Vortex impeller
Easy installation
Low noise
Water-cooled system
Leakage free
Energy saving
Space intelligent
FEATURES
TECHNICAL FEATURES
Home booster: the pump increases the pressure so that
the required pressure is available at showers, taps etc for
domestic water. The pump is used in open systems and
can be connected directly to the water main.
APPLICATIONS
PERFORMANCE
CONSTRUCTION
Easy installation
Compact
Brass impeller
/h]
0
5
10
15
20
25
30
35
40
45
50
55
H
[m]
0 10 20 30 40
Q [l/min]
0
100
200
300
400
500
p
[kPa]
PFB
50 Hz
PFB 1-30
T
M
0
2
9
8
3
3
5
0
0
4
As a guide J Lap = J0 liLres per minuLe J sprinkler = JS liLres per minuLe
2
Y
E
A
R
W
A
R
R
A
N
T
Y
47
GRUNDFOS JPB JET PUMPS
Domestic irrigation, general water transfer and water
supply from shallow wells down to 8 metres
Easy to handle
(
(
,
I
V
M
I
N
,
I
V
M
A
X
Pumps Cable P2 1 ph Water Outlet Dimensions Weight l/min 0 50 100 150 200 250
(m) (kW) In (A) temp (C) A B D H (kg)
m
3
/h 0 3 6 9 12 15
KPB300A 5 0.22 1.5 0/35 1 F 185 140 225 275 4.5 m/Head 7 5.5 4.6 3.7 2.5 -
KPB600A 5 0.55 3.4 0/35 1 F 200 160 225 376 6.7 10 8.3 7.2 6.3 5.2 3.3
KPB Vortex 330 5 0.18 0.9 0/40 1 F 205 165 250 300 4.5 6 4 1 - - -
0 2 4 6 8 I0 I2 I4
Q |m/h]
0
I
2
3
4
S
6
7
8
9
I0
R
|m]
0 40 80 I20 I60 200
Q |l/min]
0
20
40
60
80
p
|kPa]
kP8
300 A
600 (A)
1
M
0
2
9
8
3
2
S
0
0
4
2
Y
E
A
R
W
A
R
R
A
N
T
Y
KPB 600A, KPB300A and KPB Vortex 330
330 Vortex
50
GRUNDFOS PUMPS
WHAT PUMP DO I NEED?
Application Household water supply
Drainage
Irrigation
Water transfer
Other
Water source Above ground tank
Underground tank
River
Dam
Other
Power supply 240 V single phase
415 V three phase
Water requirement Household
House only
House and garden
Showers (number)
Sprinklers (number)
Sprinklers (type)
Evaporative airconditioner connected
Irrigation
Sprinklers (number)
Sprinklers (type)
Automatic Operation
Manual Operation
Drainage and Water transfer
Lift from pump (A) to point of discharge (B)
Details of existing pipeline Size (mm)
Type (Polyethylene/PVC/Copper/Steel)
Length (m)
HOW MUCH FLOW (Q)?
Water pressure systems
Weekend cottage 10 to 20 L/min
Small home 20 to 30 L/min
Average home 30 to 50 L/min
Large home 50 to 90 L/min
Average water consumption No.
Standard shower head 15 L/min
Water saving shower head 6-7 L/min
Household standard tap 10-15 L/min
Tap with aerator or ow restrictor 4-6 L/min
Lawn sprinkler 10-15 L/min
Drainage and ef uent See your Grundfos dealer
CALCULATE THE FLOW RATE
Q = ( ) L/min
1 2
3
51
WORKING IT OUT
P = Pump Head
Hd = Height diference between the pump and the highest
point of use
Hs = Pressure already available at the pump level (tank
example with positive suction head). If you pump water
under the level of the pump (well, river, underground
tank), contact your Dealer in order to calculate the suction
lift and to select the right pump.
Hf = Friction loss or pipe resistance to water ow
(see chart at right for Poly Pipe friction loss)
Pr = Residual pressure, i.e. the required pressure at the tap,
shower or sprinkler. As a guide, shower head, standard
tap or sprinkler requires approx. 150 kPa (15 m or 21 psi)
Friction loss - PN12.5 High Density Polyethylene pipe
Flow Rate
(m/100 metres of pipe)
L/min m
3
/hr L/sec 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm
12 0.7 0.2 10.9 3.7 1.1 0.4 0.1 -
24 1.4 0.4 13.4 3.9 1.3 0.4 0.1
36 2.2 0.6 8.3 2.8 0.9 0.3
48 2.9 0.8 14.2 4.8 1.6 0.5
60 3.6 1 7.2 2.4 0.8
72 4.3 1.2 10.1 3.3 1.1
84 5.0 1.4 13.5 4.4 1.5
96 5.8 1.6 5.7 1.9
108 6.5 1.8 7.1 2.3
120 7.2 2 8.6 2.8
USEFUL CONVERSION
To
Flow Conversion
From litres per minute litres per second cubic metres per hour gallons per min
1 L/min = 1 = 0.017 = 0.06 = 0.22
1 m
3
/hr = 16.7 = 0.28 = 1 = 3.7
1 L/sec = 60 = 1 = 3.6 = 13.2
1 gpm = 4.5 = 0.076 = 0.27 = 1
Example
60 L/min = 60 L/min = 1 L/sec = 3.6 m
3
/h = 13.2 gpm
To
Pressure Conversion
From metres of head kilopascal pounds/inch
2
bar
1 m = 1 = 9.8 = 1.4 = 0.1
1 kPa = 0.1 = 1 = 0.14 = 0.01
1 psi = 0.7 = 6.9 = 1 = 0.07
1 bar = 10.2 = 100 = 14.5 = 1
Example
200 kpa = 20 m = 200 kPa = 28 psi = 2 bar
HOW MUCH PRESSURE (P)?
Example
Q (Flow rate) = 60 L/min = 4 (sprinklers) x 15 L/min
Hs = 2 m
Hd = 15 m
Hf = 3.6 m
(50 m of 40 mm Poly Pipe - see Friction Loss Chart above)
Pr = 15 m (150 kPa)
P = 15 - 2 + 3.6 + 15 = 31.6 m = 310 kPa = 44 psi
CALCULATE THE PRESSURE
P = ( ) Hd - ( ) Hs + ( ) Hf + ( ) Pr
5
4
Hs
Hd
Hf
Pr
G
P
M
0
0
6
9
0
0
6
/
0
9
The name Grundfos, the Grundfos logo, and the payof
Be-Think-Innovate are registrated trademarks owned
by Grundfos Management A/S or Grundfos A/S, Denmark.
All rights reserved worldwide.
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence
Grundfos Pumps Pty Ltd
515 South Road
Regency Park SA 5010
Australia
Phone (08) 8461 4611
Fax (08) 8340 0155
contact-au@grundfos.com
Grundfos Pumps NZ Ltd
17 Beatrice Tinsley Crescent
Albany, North Shore City 0632
New Zealand
Phone (09) 415 3240
Fax (09) 415 3250
contact-nz@grundfos.com
www.grundfos.com.au