You are on page 1of 2

55-CP95SD

How to Order
BuiIt-in magnet
Bore size
Stroke (mm)
Refer to standard stroke table
following page
-
W*
Standard single rod
Double rod
Rod type
32
40
50
63
80
100
125
32mm
40mm
50mm
63mm
80mm
100mm
125mm
Mounting
B
L
F
G
C
D
Basic/Without bracket
Axial foot
Front flange
Rear flange
Single rear clevis
Double rear clevis
100 W B 32
Execution
Standard Type
Non-rotatin
piston rod
Model
55-CP95 SB
55-CP95 SDB
55-CP95 KB
55-CP95KDB
Adjustable
Stroke End
Cushioning
Piston Rod
Options
Standard
Hard Chrome
W
Model Selection
ATEX category 2
-
D
None
Built in magnet
Piston rod type
S
K**
Standard
Non-rotating
Type Model No.
Wiring
(Output)
Load voltage

n
d
i
c
a
t
o
r
Electrical entry
Applicable
load DC AC
Lead wire

(m)
0.5
(-)
3
(L)
5
(Z)
Reed
auto switch
Solid state
auto switch
D-Z73 -588
D-Z80 -588
D-Y7P -588
D-Y7PV -588
Grommet
(in-line)
Grommet
(in-line)
Grommet
(Perpendicular)
Yes
No
Yes
2-wiring
3-wiring
(PNP)
24V
24V or less
12V
48V C circuit
C circuit
Relay
PLC
For 55-CP95
When using an Auto switch, select the appropriate switch from the following table and order it separately.
AppIicabIe auto switch specifications
Auto switch only conforms to Category 3. ( 3G Ex nA T5 X -10oC b Ta b +60oC), ( 3D tD A22 P67 T93oC X)
For detailed specifications on the D-Z73, Z80, Y7P, and Y7PV, please refer to the relevant pages in Best Pneumatics.
(Note: Reed auto switches for AC 100V and DC 100V are not within the specification.)
Note 1) solid state auto switch is available after receiving an order. Lead wire length 0.5m --- Nil (e.g.) D-Z73-588
3 m --- L (e.g.) D-Z73L-588
5 m --- Z (e.g.) D-Z73Z-588
Note 2) When mounting an auto switch on a 55- series (Category 2) Model,
the ATEX category of the auto switch cylinder changes to Category 3,
which is the same category as the auto switch.
When ordering a direct mounting type auto switch,
aIso order a mounting bracket from the foIIowing Iist
at the same time.
Auto switch mounting bracket/ Part no. (Direct mounting type)
Auto switch
Model
D-Z73 -588
D-Z80 -588
D-Y7P -588
D-Y7PV -588
Tube .D. (mm)
32,40,50,63,80,100,125
BMP1-032
24V 5V,12V
48V or less
Options
Standard
W = Double Rod
Note 3)
Note 3)
Note1) 55-C95 can be used in zones 1 and 21 and in zones 2 and 22.
Note2) f the 55-C95 cylinder is used with SMC category 3 type auto switch, then the 55-C95 cylinder can only be used in zones 2 and 22 and not zones 1 and 21.
Note3) Piston rod material is stainless steel.
XC6
-
XC6
Standard
Stainless steel rod and nut
SpeciaI
* Double rod and XC6 combination available (32~100 only)
** Double rod and non-rotating
combination available
(32~100 only)
(32~100 only)
XC6
_
_
125
ATEX CompIiant
ISO CyIinder/Standard/DoubIe Acting
Series 55-CP95
32, 40, 50, 63, 80, 100, 125
7
Specifications
Bore size
ATEX category
1)
Action
Fluid
Proof pressure
Max. operating pressure
Min. operating pressure
Lubrication
Operating piston speed
Allowable stroke tolerance
Cushion
Port size
Mounting
Double acting
Air (Non-lube)
1.5MPa
1.0MPa
0.05MPa
Not required (Non-lube)
-10 to 60oC
50 to 1000mm/s
Both ends (Air cushion)
Basic, axial foot, front flange, rear flange,
single rear clevis, double rear clevis
32 40 63 100 50 80
G1/8 G1/4 G1/4 G3/8 G3/8 G1/2
Mounting Bracket, Mounting Accessories
Note 1) Accessories for each mounting bracket are as follows.
Foot, Flange, Single clevis: Mounting bolts
Double rear clevis: (D,DS): Clevis pin
Note 2) GKM according to SO 8140
Note 3) KJ according to SO 8139
Note 4) Piston rod nut is standard
Note 5) Please consult SMC
Foot
FIange
SingIe rear cIevis
DoubIe rear cIevis
DoubIe rear cIevis
(for ES accessory)
AngIed rear cIevis
with baII joint
AngIed rear cIevis
Rod cIevis
Piston rod baII joint
FIoating joint
Bore size
32 40 50 63 80 100 Description
95oC (T5) Ta -10oC to 40oC
115oC (T4) Ta 40oC to 60oC
2GDc
Note) AII other specifications
(dimensions, drawings, etc.)
are the same as the non ATEX type.
Note 1) This cylinder can be used in zones 1 and 21 and in zones 2 and 22.
f the cylinder is used with SMC category 3 type auto switch, then the
cylinder can only be used in zones 2 and 22 and not in zones
1 and 21.
L
F, G
C
D
DS
ES
E
GKM
KJ
JA
L5032
F5032
C5032
D5032
DS5032
ES5032
E5032
GKM10-20
KJ10D
JA30-10-125
L5040
F5040
C5040
D5040
DS5040
ES5040
E5040
GKM12-24
KJ12D
JA40-12-125
L5050
F5050
C5050
D5050
DS5050
ES5050
E5050
GKM16-32
KJ16D
JA50-16-150
L5063
F5063
C5063
D5063
DS5063
ES5063
E5063
GKM16-32
KJ16D
JA50-16-150
L5080
F5080
C5080
D5080
DS5080
ES5080
E5080
GKM20-40
KJ20D
JAH50-20-150
L5100
F5100
C5100
D5100
DS5100
ES5100
E5100
GKM20-40
KJ20D
JAH50-20-150
Ambient and fluid temperature
Standard Stroke
32
40
50
63
80
100
125
Bore size
(mm)
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800
Each stroke will be made to order
Standard stroke (mm)
(*) ntermediate strokes are available
Maximum Stroke
32
40
50
63
80
100
125
Bore size
(mm)
Standard
1000
1000
1000
1000
1000
1000
1000
1900
1900
1900
1900
1900
1900
2000
Single
rod
Double
rod
Non-rotating (K)
500
500
600
600
800
800
-
500
500
600
600
800
800
-
Single
rod
Double
rod
XC6
1000
1000
1000
1000
1000
1000
-
1700
1700
1700
1700
1700
1700
-
Single
rod
Double
rod
125
50 to 700
mm/s
G1/2
+1.0
0
+1.4
0
to 250: , 251 to 1000: 1001 to 1500: , 1501 to 2000:
+1.8
0
+2.2
0
L5125
F5125
C5125
D5125
125
Note 5)
DoubIe Acting/
DoubIe Rod
DoubIe Acting/
DoubIe Rod
SymboI
DoubIe Acting/
SingIe Rod
DoubIe Acting/
SingIe Rod
Non-rotating rod:
ATEX CompIiant ISO CyIinder/Standard Series 55-CP95