You are on page 1of 148

york air-conditioning products

Commercial & Industrial HVAC

On the cover... This shapes lines are taken from the ultra-modern building shape of the Montreal Biodome. Building Efficiency provides all heating and air conditioning controls to deliver safe and comfortable conditions for the facilitys different inhabitants - ranging from Antarctic temperatures for the penguins to hot and humid conditions for the tropical plants.

york air-conditioning products

A more comfortable, safe and sustainable world

At Johnson Controls, we look at buildings in a way very few others have ever imagined. When we look at a building, we see beyond the bricks and mortar. Beyond the steel and glass. We see a bigger picture. We see the power of the human enterprise. Thats why we create buildings and environments that help people achieve and that give buildings, businesses and people every opportunity to reach their full potential.

york air-conditioning products

Solutions for your success


Every building is unique in design and technical requirements. Our customers always receive customised building solutions to meet their individual needs. Johnson Controls can handle many challenges with its innovative and flexible solutions. From A to Z, from consulting to planning, installation, maintenance (service, inspection and repair) and modernisation Johnson Controls supports customers throughout the entire life cycle of a building.

AIR CONDITIONING SOLUTIONS Chillers & fan coils Absorption chillers Cooling towers Dry coolers Air Handling Units

BUILDING AUTOMATION Monitoring, control and optimisation Standardised communication protocols

SECURITY SOLUTIONS Identity management Facility zoning Video surveillance systems Alarm systems

06/07

Our well thought-out solutions guarantee a high level of comfort and energy efficiency. The majority of our products are already rated as Class A for Energy Efficiency, with high levels of compatibility and flexibility allowing for future additions to be carried out without difficulty.

External systems can be easily integrated using BACnet or proprietary solutions. Our service team is available to you 24 hours a day with one of the largest service networks in Europe.

AIR CONDITIONING SOLUTIONS Air systems VRF systems Roof-top air-conditioners Minisplits

ROOM AUTOMATION Integration of HVAC controls with lighting and automatic blinds

SERVICE & SOLUTIONS Maintenance solutions Modernisation solutions Energy performance contract solutions Renewable energy solutions

ENERGY MANAGEMENT Energy monitoring Real time consumption Mgmt Continuous commissioning

york air-conditioning products

Catalogue content
Page

Chillers & Heat Pumps


ECOFRIO v2 / ECOFRIO v2 Plus Air cooled chiller / heat pump ECOFRIO v2 Air cooled chiller / heat pump YLCD-YLHD Air cooled chiller / heat pump YLAA Air-cooled scroll compressor chiller YLAE-HP Reverse cycle air to water heat pump scroll compressor chiller YLPA Heat pump scroll compressor YVAA Air-cooled VSD screw chiller YMWA / YMRA Water-cooled cooling only, remote condenser and heat pump scroll compressor chiller YCSE Water-cooled or remote air-cooled screw compressor chiller YCWL Water-cooled or remote air-cooled scroll compressor chiller YLCS Water-cooled or remote air-cooled screw compressor chiller YVWA Water-cooled variable speed screw chiller YN Water-cooled screw compressor chiller YR Water-cooled screw compressor chiller YNWS/RS Water-cooled or remote air-cooled screw compressor chiller YNWH Water-cooled screw chiller YMC2 Water-cooled magnetic centrifugal chiller YK Water-cooled centrifugal chiller YIA Single stage hot water or steam powered absorption chiller YPC-ST Two-stage steam fed absorption chiller YPC-F Two-stage direct fired chiller-heater Central Plant Optimization 10 12 16 20 24 26 28 30 32 33 34 36 38 40 42 44 45 46 48 50 52 53 54

08/09

Page

Air Handling Systems & Terminal Devices


YMA Custom air handling units YMA-C Hygienic Air Handling Units YFCN Fan Coil Unit centrifugal fan YFCN-ECM Fan Coil Unit Inverter with centrifugal fan LASER & LOW BODY Fan Coil Units YEFB Hydro Blower YGFC Fan Coil Unit YHK Hydro Cassette YHK ECM Inverter Hydro Cassette YFCC Coanda Hydro Cassette YFCC-ECM Coanda Hydro Cassette Inverter YHM Hydro High Wall YORK YC-P Series Close Control Air Conditioners SmartPac - Factory Packaged Control 60 61 64 70 72 78 80 82 84 88 90 94 98 106

Packaged Equipment & Large Split Systems


Roomtop RTC-RTH - L ACTIVA Rooftop ARC-ARG-ARH-ARD 017 to 040 AB ACTIVA Rooftop ARC-ARG-ARH-ARD 045 to 090 AB Large Rooftop DIC-BIH-DIG 360 to 480 G VITALITY Axial Fan Large Split VAC/VAH - VIR 20 to 90 AB VITALITY Centrifugal Large Split VCH-VIR 20 to 90 AB 114 116 120 126 130 136

Comprehensive Building Solutions


Metasys Building Automation and Control Systems 144

york air-conditioning products

10/11

Chillers & Heat Pumps


scroll compressor chillers and heat pumps screw compressor chillers air-cooled & water-cooled centrifugal compressor chillers water-cooled absorption chillers water-cooled central plant optimisation tm 10

york air-conditioning products

ECOFRIO v2 / ECOFRIO v2 Plus Air cooled chiller / heat pump


YLCA 12 to 27 / YLHA 12 to 27 Plus
A complete range from 12 kW up to 25.8 kW

Features
Scroll compressor units Very compact units High efficiency units Leaving and return water temperature control Hydro pack standard Buffer tank supresion function Dynamic set point function Fan speed control as standard Coated condenser fins as standard (blue fin) Flow switch and water filter included

Options / Accessories
Condenser copper fins BMS Communication Remote control / Remote terminal High pressure fans External buffer tank Tray cable heater (YLHA Plus) Condenser protection grill

External Buffer tank in accessories

12/13

ECOFRIO v2 / ECOFRIO v2 Plus


YLCA 12 to 27 / YLHA 12 to 27 Plus

Technical features
Model
Performance

T Three phases supply C Hydro Pack YLCA G1 15 TC 20 TC 14.5 19.5 5.4 6.9 2.52 2.81 2.91 3.24 YLHA PLUS G1 15 TC 20 TC 13,8 19.4 5.5 7 2,52 2,75 2.91 3.17 16,1 20.9 5.2 6.6 3,12 3,17 16.4 20.5 4.0 3,79 27 TC 25.8 8.9 2,9 3.25 27.5 8.6 3,2 26.8 3,8 78 48

12 TC 27 TC 12 TC Cooling capacity (1) kW 12.4 25.6 12 Total Input Power (1) kW 4.2 9,1 4.2 EER (1) 2.97 2.81 2,88 ESEER 3.20 3.17 3.08 Heating capacity (1) kW 12,4 Total Input Power (1) kW 4.2 COP (1) 3.0 Heating capacity (2) kW 12.6 COP (2) 3,86 Capacity steps % 0 / 100 Sound power level dB(A) 73 73 74 78 73 73 74 Sound pressure level at 10 m dB(A) 43 43 44 48 43 43 44 Scroll Compressor Type Quantity 1 2 Air side heat Fans quantity exchanger Working ambient temp. cool / heat mode (5) (-18C) -10C ~ 46C -18C ~ 46C -18C ~ 46C / -15C ~ 20C Type Plate Heat Exchanger Water side heat Unit water volume Litres 1.5 2 2.8 3.2 1.5 2 2.8 exchanger Pump Type Multi stage Nominal water flow in cooling l/h 2 065 2 530 3 360 4 405 1 980 2 375 3 335 Available pressure (1) (3) kPa 113 149 129.5 182 116 157.5 124 Working water leaving temp. C -5C to 15C / 30C to 50C cooling/heating mode (4) Water connections inch 1 1 1/4 1 1 1/4 mm 1 270 / 905 / 460 1270/1430/502 1270/1876/502 1 270 / 905 / 460 1270/1430/502 Dimensions Height / Width / Depth & Weight Weight kg 146 160 220 290 150 164 235 Voltage / Phases / Frequency V/ph/hz 400-3-50+N+E Electrical features Maximum Unit current A 11.6 15.8 18.1 23 11.6 12.4 15.5 (1) net values at Nominal conditions (2) net values at floor heating conditions (3) with filter (4) below 6C with glycol (5) -18C with LAK option Nominal conditions: Cooling capacities for 7C water leaving temperature t 5C and 35C ambient temperature Heating capacities for 45C water leaving temperature t 5C and 7C ambient temperature Floor heating conditions: Heating capacities for 35C water leaving temperature t 5C and 7C ambient temperature

3.2 4 440 182

1270/1876/502 330 21

Compatibility table / Codes


YLCA Model 12 TC 15 TC 20 TC 27 TC

Cooling only units (Pack included)


YLHA Plus Model

S668551282

S668551582

S668552082

S668552782
12 TC 15 TC 20 TC 27 TC

Heat pump units (Pack included) Use this unit code when a factory fitted option is NOT required Accessories (Supplied loose) 30 Liters Water tank 115 Liters 30 L + 4.5 kW (3~) Water tank + heater 30 L + 6 kW (3~) 115 L + 10.5 kW (3~) Remote control Remote terminal BMS Communication Anti vibration mounting Compressor heater Tray cable heater
YLCA Model

S668651285

S668651585

S668652085

S668652785

S613990300 -

S613991150

S613990300 S613990305 S613990306 S613802011 S613802231 S613802041

S613991150 S613991151

S613029001 S613760322 12 TC 15 TC

S613029002 STANDARD

S613029001 S613760322 S611080788

S613029002 STANDARD -

20 TC

27 TC

Cooling only units (Pack included)


YLHA Plus Model

S668000010

S668000012

S668000014

S668000016
12 TC 15 TC 20 TC 27 TC

Heat pump units (Pack included) Use this unit code when a factory fitted option is required Options (Factory fitted) High pressure fans Condenser protection grill LAK -18C S611991083 S613995085 S613112083 S611991085 S61399087

S6686000239 S6686000242 S6686000243 S6686000244

S61399086

S611991083 S613995085 STANDARD

S61399086

S611991085 S61399087

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

Dimensions, hydraulic connections and space requirements


YLCA-YLHA PLUS 12/15 TC

1238

WATER INLET 1G WATER OUTLET 1G

DRAIN CONNECTION EXT. 15

405

905

All dimensions in mm. Drawings not a scale.

YLCA-YLHA PLUS 20/27 TC

0) e2 ) siz 27 0 ( size 3 14 76 ( 18
50 2

All dimensions in mm. Drawings not a scale.

1270

1270

14/15

YLCA-YLHA PLUS 12 to 27
Models YLCA-YLHA PLUS 12/15

All dimensions in mm. Drawings not a scale.

Models YLCA-YLHA PLUS 20/27

300

1000

300

WATER INLET AND OUTLET

600

300

600

800

All dimensions in mm. Drawings not a scale.


800

800

WATER INLET AND OUTLET

1000

800

800

1000

Water Systems

york air-conditioning products

ECOFRIO v2 Air cooled chiller / heat pump


YLCA / YLHA 40 to 150
A complete range from 39.6 kW up to 151 kW

Features
YLCA/YLHA 40 to 80
2 capacity steps (1 for size 40) LWT & RWT Control Hydro Pack standard Buffer tank integrated Plate heat exchanger Condenser fins (blue fin) Pressostatic LAK (-18C)

Options / Accessories
Unit without pack BMS Communication Remote control Remote terminal Water filter (unit without Hydro Pack) Flow switch (unit without Hydro Pack) Low noise version Dual pump version Antivibration mountings Condenser protection grille

YLCA/YLHA 100 to 150


Same features as YLCA/YLHA 40 to 80 4 capacity steps High efficiency at full and partial load Reduced noise levels 1/4 turn lock for easy access

16/17

ECOFRIO v2
YLCA / YLHA 40 to 150
Technical features
Model Cooling capacity c/o units (1) kW Total Input Power (1) (3) kW EER (1) ESEER (1) Cooling capacity h/p units (1) kW Heating capacity h/p units (1) kW Performance Total Input Power cool/heat mode (1) kW EER / COP (1) ESEER (1) Capacity steps % Sound power level STD / LN dB(A) Sound press. level 10 m STD / LN dB(A) Type Compressor Quantity Fans quantity Air side heat exchanger Working ambient temp. cool. / heat. mode (4) Type Unit water volume (2) Litres Pump Type Nominal water flow l/h Water side heat Available pressure (1) (2) kPa exchanger Pressure drop (1) (3) kPa Working range water leaving temperature cooling / heating (5) Water connections (2) inch Height / Width / Depth mm Dimensions Weight without pack / pack c/o kg & Weight Weight without pack / pack h/p kg Voltage / Phases / Frequency V/ph/hz Electrical features Maximum Unit current A 40 T-TP 39.6 13.26 2.99 3.31 37.8 38.6 13.3 / 12.6 2.84/3.14 3.30 0 / 100 81 / 76 54 / 48 1 50 T-TP 52.1 17.96 2.9 3.24 52 52.5 17.3 / 17.9 3/2.93 3.24 83 / 78 56 / 50 60 T-TP 60.5 19.6 3.09 3.44 60.5 59.6 19.6 / 19.8 3.09/3.01 3.44 0-50-100 85 / 80 57 / 51 2 T Three phases supply P Hydro Pack H Heat pump YLCA / YLHA 80 T-TP 77.6 26.6 2.92 3.26 72.2 74.7 26 / 26.4 2.78/2.83 3.26 86 / 82 60 / 54 Scroll 100 T-TP 98 33.8 2.9 3.56 96 104 35.5 / 37.1 2.7 / 2.8 3.65 86 / 82 57 / 54 120 T-TP 119 40 2.98 3.80 114 119.6 43.2 / 39.6 2.64/3.02 3.71 0-25-50-75-100 86 / 82 58 / 54 150 T-TP 151 53.6 2.82 3.60 145 150 50.6 / 53.5 2.87/2.8 3.7 87 / 83 59 / 55

131 6 820 105 75

4 3 4 -18C ~ 46C / -10C ~ 20C Single Plate Heat Exchanger Dual Plate Heat Exchanger 188 194 285 193 195 Multistage horizontal pumps 8 960 10 400 13 350 17 600 20 470 108 158 123 187 202 40 51 61 54 32 2 -5C ~ 15C / 30C ~ 50C

214 25 970 186 27.5

1 1/4 1573/1500/822 340 / 380 337 / 397 33

2 1600 / 1011 / 2104 524 / 580 555 / 611 537 / 593 568 / 624 46.2 49.2

2 1/2 1600/1118/2944 2190 / 1101 / 3416 715 / 785 1 124 / 1 220 1 190 / 1 286 735 / 805 1 154 / 1 250 1 220 / 1 316 400 / 3 / 50+N+E 70.5 80 108

2263/1101/3770 1 415 / 1 503 1 445 / 1 703 120

YLCA: Cooling only units models. YLHA: Air to water heat pump models. (1) net values at Eurovent nominal conditions (2) version P with hydro kit with filter (3) version without hydro kit (4) -18C with LAK option Nominal conditions: Cooling capacities in kW given for 7C water leaving temperature t 5C and 35C ambient temperature Heating capacities in kW given for 45C water leaving temperature and 7C ambient temperature

(5) below 6C with glycol

Compatibility table / Codes


Model YLCA Cooling only unit (Pack included) YLHA Heat pump unit (Pack included) 40 TP S668554084 S668654084 50 TP S668525182 S668625182 50 T S668525180 S668625180 60 TP S668526182 S668626182 60 T S668526180 S668626180 80 TP S668528182 S668628182 80 T S668528180 S668628180 100 TP S668521182 S668621182 100 T S668521180 S668621180 120 TP S668551156 S668651156 120 T S668551154 S668651154 150 TP S668551507 S668651506 150 T S668551503 S668651504

Model 40 T YLCA Cooling only unit (without Pack) S668554080 YLHA Heat pump unit (without Pack) S668654080 Use this unit code when a factory fitted option is NOT required Accessories (Supplied loose) AVM mounting S613029002 Mechanical flow switch Water Filter * S611300150 Remote control Remote terminal Cable for remote connection of the terminal B.M.S. Communication Model YLCA Cooling only unit (Pack included) YLHA Heat pump unit (Pack included) 40 TP S668000226 S668000228

S613026080 S611300170

S613028180 S611992021 S613802011

S613021580 S611300190 S613802241 S613802051

S613802231 S613802041 50 TP S668000247 S668000248 50 T S668000245 S668000246 60 TP S668000251 S668000252 60 T S668000249 S668000250 80 TP S668000255 S668000256 80 T S668000253 S668000254 100 TP S668000259 S668000260 100 T S668000257 S668000258

120 TP S668000107 S668000131 120 T S668000105 S668000129

150 TP S668000111 S668000135 150 T S668000109 S668000133

Model 40 T YLCA Cooling only unit (without Pack) S668000038 YLHA Heat pump unit (without Pack) S668000039 Use this unit code when a factory fitted option is required Options (Factory fitted) Low Noise version S603990550 Softstart S606744692 Dual pumps Condenser protection grille S613995090

S613990650 S606744693 S613990540 S613990640 S613995091

S613990850 S613990840 S613995092

S613991285 S606744694 S613991040 S613991286 S613995093

S613991050

S613991584 S613991585 S613995094

* included with unit version P only for unit without pack. Filter size: 2 for YLCA 40-50-60-80 and 2 1/2 for YLHA 100-120-150.

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

Dimensions, hydraulic connections and space requirements


YLCA-YLHA 40 T-TP YLCA-YLHA 50 and 60 T-TP

1573

210
82
0 150

10

11

All dimensions in mm. Drawings not a scale.

All dimensions in mm. Drawings not a scale.

YLCA-YLHA 80 T-TP

YLCA-YLHA 100, 120 and 150 T-TP

294

4
110 1

120 00A1 LH 150) A A-Y LC -YLH Y 6 ( CA 341 0 (YL 377

111

All dimensions in mm. Drawings not a scale.

All dimensions in mm. Drawings not a scale.

2190 (YLCA-YLHA 100-120) 2263 (YLCA-YLHA 150)

1600

1600

300

1000

WATER INLET AND OUTLET

18/19

300

1000

YLCA / YLHA 40 to 150


300 600
800
300 600
800

YLCA-YLHA 40 T-TP

YLCA-YLHA 50, 60 and 80 T-TP

800

WATER INLET AND OUTLET


WATER INLET AND OUTLET

INLET / OUTLET WATER

800

800
800
800 00 8

1000
1000

1000

1000

1500

33000 000

1000

INLET / OUTLET WATER

1000

1500

All dimensions in mm. Drawings not a scale.

1000

All dimensions in mm. Drawings not a scale.

YLCA-YLHA 100, 120 and 150 T-TP

3000

1000

WATER WATER INLET / INLET / OUTLET OUTLET

1000

1000

1500

1500

1500

1500

All dimensions in mm. Drawings not a scale.

1500

1500

3000

3000

Water Systems

WATER INLET AND OUTLET

york air-conditioning products

YLCD-YLHD Air cooled chiller / heat pump


YLCD-YLHD 25 to 150
A complete range from 24 kW up to 145 kW

Features
Centrifugal or radial fans Scroll compressor Vertical and horizontal discharge Integrated Hydro kit (P versions) LAK (-18C) standard Flow switch standard

Options / Accessories
Vertical Discharge kit (sizes 25 to 70) Low Noise (sizes 100 to 150) Dual Water Pumps (sizes 100 to 150) Water filter and water flow switch Antivibration mounting Remote control and remote terminal BMS communication

EC Radial Fans (sizes 100 to 150), using new high efficiency ventilation technology to improve the overall performance.

Integrated Hydrokit, shared with YLCA/YLHA product platform, for a compact and quick installation.

20/21

Air cooled chiller & heat pump


YLCD-YLHD 25 to 150
Technical features
Models Cooling capacity c/o units (1) kW Total Input Power (1) kW EER (1) Cooling capacity h/p units (1) kW Performance Heating capacity h/p units (1) kW Total Input Power cool/heat mode (1) kW EER / COP (1) Capacity steps % Sound power level dB(A) Type Compressor Quantity Fans quantity Air side Air flow (50 Pa) m3/h heat exchanger Working ambient temp. cool. / heat. mode Type Unit water volume Litres Pump Type l/h Water side Nominal water flow heat Available pressure (1) (2) kPa exchanger Pressure drop (1) (3) kPa Working range water leaving temperature cooling / heating (5) Water connections inch Height mm Width mm Dimensions Depth mm & Weight Weight without pack / pack c/o kg Weight without pack / pack h/p kg El. supply Voltage / Phases / Frequency V/ph/hz 25 TC 24 8.3 2.9 23 24 8.0 / 8.0 2.9 / 3.0 100 81 1 1 6 500 40 T-TP 40 15.5 2.6 40 43 15.5 / 15.4 2.6 / 2.8 50-100 83 86 Scroll 2 2 4 4 4 2 2 4 4 4 11 000 14 500 18 000 20 000 24 000 (4) (-18C) ~ 46C / -10C ~ 20C -18C ~ 46C / -10C ~ 20C Single plate heat exchanger Dual plate heat exchanger 32 84 92 193 195 214 Multistage horizontal pump 4 300 6 880 12 040 17 030 20 470 24 940 208 105 120 187 202 186 31 53 54 140 198 -5C ~ 15C / 30C ~ 50C 1-1/4 1 526 1 740 785 - / 390 - / 400 2 1 794 2 659 897 730 / 770 750 / 790 1 794 2 460 2 659 3 466 897 1 101 740 / 780 1 264 / 1 360 760 / 800 1 284 / 1 380 400 / 3 / 50 + N + E 2-1/2 2 460 3 416 1 101 1 264 / 1 360 1 284 / 1 380 2 480 3 768 1 101 1 680 / 1 776 1 700 / 1 796 86 T Three phases supply C/P Hydro Pack H Heat pump YLCD / YLHD 70 T-TP 100 T-TP 70 99 27.5 39.5 2.6 2.5 68 96 72 104 26.0 / 26.0 38.5 / 37.0 2.6 / 2.8 2.5 / 2.8 120 T-TP 119 47.5 2.5 117 119.6 46.8 / 42.7 2.5 / 2.8 25-50-75-100 86 150 T-TP 145 60.0 2.4 143 159 60.0 / 58.5 2.4 / 2.7 87

YLCD: Cooling only units models. YLHD: Air to water heat pump models. (1) net values at Eurovent nominal conditions (2) version P with hydro kit with filter (3) version without hydro kit (4) -18C with LAK option Nominal conditions: Cooling capacities in kW given for 7C water leaving temperature t 5C and 35C ambient temperature Heating capacities in kW given for 45C water leaving temperature and 7C ambient temperature

(5) below 6C with glycol

Compatibility table / Codes


Models Cooling only unit YLCD Heat pump unit YLHD Models 25 TC Cooling only unit YLCD S668592580 Heat pump unit YLHD S668572580 Use this unit code when a factory fitted option is NOT required Accessories (Supplied loose) AVM mounting Flow switch Remote control Remote terminal Cable for remote connection of the terminal B.M.S. Communication Vertical air discharge 40 T S668594083 S668574083 40 TP S668594080 S668574080 70 T S668597083 S668577083 70 TP S668597080 S668577080 100 T S668591083 S668571083 100 TP S668591080 S668571080 120 T S668591283 S668571283 120 TP S668591280 S668571280 150 T S668591583 S668571583 150 TP S668591580 S668571580

S613029002

S613028180 S611992021 S613802011

S613021580

S612828405

S613802231 S613802041 S612828205 40 T S668000264 S668000266 40 TP S668000265 S668000267 70 T S668000268 S668000270 70 TP S668000269 S668000271 100 T S668000272 S668000274 100 TP S668000273 S668000275

S613802241 S613802051 Standard 120 T S668000276 S668000278 120 TP S668000277 S668000279 150 T S668000280 S668000282 150 TP S668000281 S668000283

Models Cooling only unit YLCD Heat pump unit YLHD Models 25 TC Cooling only unit YLCD S668000262 Heat pump unit YLHD S668000263 Use this unit code when a factory fitted option is required Options (Factory fitted) Low noise NA Dual pump NA Coil guard net Low Ambient Kit S613114084 Soft start S606744692 Copper/copper condenser

S613990550 NA Standard S613111084 S606744693

S613991050 S613991285 S613991040 S613991286 S613995093 Standard S606744694 Contact Johnson Controls

NA NA

S613991584 S613991585 S613995094

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

Dimensions, hydraulic connections and space requirements


YLCD / YLHD 25 TC
600 D E 600 * 600 600

Q
270 222

Electrical connections

Minimum clearance

* No clearance required if air ducted

Q Water outlet, 1-1/4 Gas F W Water inlet, 1-1/4 Gas F

All dimensions in mm. Drawings not a scale. Unit YLDC/YLHD 25 TC A 1 526 B 1 740 C 785 D 151 E 1436 F 30 G 324 H 37 I 994 J 141 K 1476 L 24

YLCD / YLHD 40-70 T/TP


600 D E F G 600 * 600 600

Q
466 (40-70T) 880 (40-70TP)

Electrical connections

211

Minimum clearance
All dimensions in mm. Drawings not a scale. Unit YLDC/YLHD 40 T/TP YLDC/YLHD 70 T/TP A 1 794 1 794 B 2658 2658 C 897 897

* No clearance required if air ducted

Q Water outlet, 2 Gas F W Water inlet, 2 Gas F

D 148 148

E 1155 1155

F 95 95

G 1155 1155

H 30 30

I 389 389

J 37 37

K 1 200 1 200

L 138 138

M 2479 2479

N 23 23

22/23

YLCD-YLHD 25 to 150
YLCD / YLHD 100-120 T/TP

1 2 3

Q Water outlet, 2-1/2 Gas F W Water inlet, 2-1/2 Gas F E Diameter drain tube, 20 mm
All dimensions in mm. Drawings not a scale. Unit YLDC/YLHD 100 T/TP YLDC/YLHD 120 T/TP A 3 466 3 416 B 183 183 C 1 550 1 525 D 704 604 E 2 058 2 208 F 1 942 1 942 G 2 460 2 460 H 500 500 I 410 418 J 59 55 K 1 450 1 438 L 200 200 M 290 290 N 380 380

YLCD / YLHD 150 T/TP

1 2 3

Q Water outlet, 2-1/2 Gas F W Water inlet, 2-1/2 Gas F E Diameter drain tube, 20 mm
All dimensions in mm. Drawings not a scale. Unit YLDC/YLHD 150 T/TP A 3 768 B 254 C 1 630 D 605 E 2 558 F 1 992 G 2 480 H 470 I 386 J 55 K 1 617 L 410 M 210 N 458

Water Systems

york air-conditioning products

YLAA
Air-cooled scroll compressor chiller
Cooling capacities from 177 kW to 521 kW

Features
The YORK YLAA TEMPO air-cooled chiller is an environmental leader. Utilising scroll type compressors and microchannel condenser coil technology the YLAA delivers premium efficiency for all air conditioning applications. YLAA chillers are a self-contained cooling solution that is light-weight and compact for convenient installation on the ground or on building rooftops.
There are 4 versions COOLING ONLY YLAA SE YLAA SE LS YLAA HE YLAA HE LS Standard Efficiency Standard Efficiency, Low sound High Efficiency High Efficiency, Low sound

The TEMPO delivers energy efficiency levels that surpasses Eurovent A Class requirements. Aluminun microchannel condenser coil technology is one reason for this premium efficiencies.

Ultra quiet operation can be obtained through optional dual or low speed fans and a compressor accousitc enclosure. A single point power connection and optional, factory packaged water pumps, water filter and flow switch provide fast and easy installation.

An optional heat recovery feature can be added to provide hot water to 50C; which is useful for facility heating or hot water preheating.

Supplies chilled liquid at temperatures between -1C and 15C. Operates in ambient temperatures from -18C to 46C fully loaded.

24/25

Air-cooled scroll compressor chiller


YLAA 180 to 515
Nominal capacity
YLAA SE Standard Cooling capacity (kW) EER ESEER Sound pressure at 10 m (dBA) YLAA SE LS Standard & Low sound Cooling capacity (kW) EER ESEER Sound pressure at 10 m (dBA) (1) YLAA HE High Efficiency Cooling capacity (kW) EER ESEER Sound pressure at 10 m (dBA) YLAA HE LS High Efficiency & Low sound Cooling capacity (kW) EER ESEER Sound pressure at 10 m (dBA) (1) 180 179 2.84 3.95 57 180 177 2.75 3.88 49 195 196 3.08 4.39 57 195 194 2.98 4.26 49 210 196 2.41 3.42 58 210 193 2.30 3.34 50 260 253 3.03 4.72 61 260 248 2.94 4.59 55 240 218 2.69 3.65 59 240 214 2.63 3.67 52 300 310 3.10 4.14 61 300 304 3.01 4.22 54 285 276 2.71 4.09 61 285 269 2.59 4.01 55 350 346 3.10 3.99 62 350 340 3.03 4.01 55 320 310 2.56 3.97 62 320 301 2.42 3.89 55 390 386 3.03 4.15 63 390 377 2.93 4.22 56 360 344 2.66 3.94 62 360 336 2.54 3.96 55 400 386 2.55 3.79 62 400 374 2.41 3.79 55 440 429 3.04 4.14 63 440 421 2.96 4.19 56 435 418 2.69 3.92 64 435 408 2.57 3.89 57 455 451 3.07 4.17 64 455 443 3.01 4.22 57 485 466 2.57 3.83 64 485 452 2.43 3.80 57 515 521 3.06 4.33 64 515 510 2.96 4.37 57

At leaving chilled water temperature of 7C, and ambient temperature of 35C. (1) Low sound models with acoustically lined compressor enclosure, and fixed low speed fans.

Technical data
YLAA SE Standard Dimensions Operating weight kg YLAA SE LS Standard & Low sound Length Dimensions Width Height Operating weight kg YLAA HE High Efficiency Dimensions Operating weight kg YLAA HE LS High Efficiency & Low sound Length mm Dimensions Width mm Height mm Operating weight kg Length Width Height mm mm mm 2165 195 2911 mm mm mm 1871 195 2911 1905 260 Length Width Height mm mm mm 1715 180 1749 210 180 210 240 2911 285 320 2242 2508 2469 320 2242 2508 2625 350 3690 2242 2508 2328 260 3041 300 2805 350 3690 2242 2508 2321 2484 3236 3000 3346 4028 4097 4387 3151 390 3833 440 3902 455 4807 4192 515 390 360 400 3690 435 485

1848 240 2911

2367 285

3254 360

3339 400 3690

3108 435

3290 485

2004 300

2523

3449

3534 440

3303 455 4807

3485 515

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YLAE-HP
Reverse cycle air to water heat pump scroll compressor chiller
Cooling capacities from 183 kW to 426 kW Heating capacities from 187 kW to 469 kW

Features
The YORK YLAE-HP TEMPO air-cooled scroll compressor chillers, provides cool and heating for all air conditioning applications with higher performances. They are completely autonomous and are designed to be installed outdoors on the roof of a building or at ground level.

Options / Accessories
Water circulating pumps / expansion device factory fitted Water filter and flow switch factory fitted Power Factor Correction BAS interface BACnet or MODBUS protocol interface Evaporator extension kit Victaulic coupling and flange kits Wire mesh protection guards

26/27

Reverse cycle air to water heat pump scroll compressor chiller


YLAE-HP 200 to 480
Nominal capacity
YLAE HP Cooling capacity (kW) EER ESEER Heating capacity (kW) EER Sound pressure at 10 m (dBA) w/o encapsulating Sound pressure at 10 m (dBA) with encapsulating 200 HP 183 2.52 3.8 187 2.67 59 54 240 HP 218 2.67 3.9 225 2.81 61 58 260 HP 237 2.67 3.99 247 2.82 61 57 300 HP 269 2.75 3.85 287 2.9 62 58 330 HP 298 2.7 3.81 322 2.85 62 58 370 HP 342 2.51 3.67 361 2.71 64 60 440 HP 387 2.52 3.77 421 2.68 63 60 480 HP 426 2.42 2.62 469 2.67 63 60

Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12C/7C, ambient temperature 35C Heating Capacity at Eurovent Conditions, entering/leaving hot water temperature 40C/45C, ambient temperature 7C All models incorporates two cooling circuits

Technical data
YLAE HP Dimensions Operating weight kg Length Width Height mm mm mm 1978 200 HP 240 HP 3008 260 HP 2214 2422 2449 2265 2525 2614 3235 3694 3728 300 HP 3556 330 HP 370 HP 3946 2215 440 HP 5012 2216 2217 480 HP

TEMPO have fitted low noise and streamlined design fans. A two-speed optional fan provides lower noise levels in outdoor low temperature.

TEMPO has a microprocessor controller with display of 40-character and simple language, indicating temperatures, pressures, operating hours, number of starts, the time of start / stop and vacations. The control functions include the exact temperature of the liquid output, main / secondary compressors, security circuit protection and integrated circulators.

TEMPO has optional encapsulated soundproofing for the compressor, in order to reduce the noise level.

TEMPO provides, optionally, single or double integral water circulators and an expansion vessel. The pumps are manufactured in high or low pressure versions to meet high design gauge.

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YLPA
Heat pump scroll compressor
Cooling capacities from 342 kW to 647 kW Heating capacities from 351 kW to 666 kW
At Eurovent Standard Conditions most high efficiency models meet A Class energy efficiency levels.

Features
The YLPA heat pump delivers premium energy efficiency, it is easy to install, quiet to run, and it is supported by a knowledgable service force. Efficiency Eurovent A-Class certified full load efficiency, high part load efficiency, improved defrost cycle, extended operating envelope. Maximize heating efficiency and renewable energy use with the YLPA heat pump. Sound Designed for quiet operation at full and part load conditions. Sustainability European Commission 2020 renewables targets compliant, specifically designed for HFC-410A. Ease of installation Quick and easy to install, compact design, Metasys ready. Reliability The YLPA is our third generation of fully factory tested scroll heat pumps, and thanks to our extensive service solutions, support and minimal maintenance are assured.

Multiple scroll design enables sound reduction during part load operation by simply turning off unnecessary compressors

28/29

Heat pump scroll compressor


YLPA 340 to 640
Nominal capacity
YLPA SE Standard Cooling capacity (kW) Cooling EER ESEER Heating capacity (kW) Heating EER Sound pressure at 10 m (dBA) YLPA HE High Efficiency Cooling capacity (kW) Cooling EER ESEER Heating capacity (kW) Heating EER Sound pressure at 10 m (dBA) 340 342 3.08 4.0 351 3.11 54 355 359 3.26 4.5 369 3.27 55 415 424 3.01 4.1 439 3.18 55 425 444 3.24 4.5 460 3.22 55 495 513 3.00 4.1 527 3.19 56 505 526 3.23 4.6 554 3.20 55 560 568 2.96 3.9 581 3.17 55 570 590 3.11 4.4 600 3.24 56 610 636 2.97 3.9 666 3.10 56 640 647 3.02 4.4 666 3.23 56

Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12C/7C, ambient temperature 35C Heating Capacity at Eurovent Conditions, entering/leaving hot water temperature 40C/45C, ambient temperature 7C Sound Pressure according to Eurovent conditions. LS models

Technical data
YLPA SE Standard Dimensions Operating weight kg YLPA HE High Efficiency Dimensions Operating weight kg Length Width Height mm mm mm Length Width Height mm mm mm 4600 355 4937 340 415 4937 495 2246 2501 5200 505 2246 2501 6100 560 5854 610 6971

5000 425 5854

5695 570 6971

6235 640

4750

5400

6495

6695

High Efficiency Cooling Mode


Heat Pump efficiency (ESEER) Annual energy cost

Additional Energy Savings in Heating Mode


Heat Pump efficiency Running cost (Euros/kWh of useful heat)

4.7 4.5 4.3 4.1 3.9 3.7 3.5 3.3 3.1


Typical 10-15 year old Heat Pump Typical Heat Pump today

- 27,000

3.5 3.0 2.5 2.0

-0.035

39%

- 25,000 - 23,000

10%

-0.033

17%

-0.031

- 21,000 - 19,000 - 17,000 - 15,000

1.5 1.0

-0.029

-0.027 0.5 0.0

YLPA Heat Pump

Typical Boiler today

YLPA Heat Pump

-0.025

500 kW unit, 3000 operating hours, energy rate = 0.1 EUR / kWh

Energy Rate: Electricity 0.1 EUR / kWh; Gas 0.03 EUR / kWh

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YVAA
Air-cooled VSD screw chiller
Cooling capacities from 525 kW to 1225 kW
At Eurovent Standard Conditions this equipment meets A Class energy efficiency levels.

Features
Reduce your annual energy costs by as much as 30% Reduce your sound levels by up to 16 dBA to meet tighter regulations Enhance your flexibility with a variety of chiller options to fit your needs Minimise your environmental impact dramatically Lower your part load energy and night time sound levels with inverter fans and compressors Deliver increased motor longevity and increased chiller reliability with low starting currents Cut your operational expenses with a high chiller power factor at all loads Improve your peace of mind knowing we stand behind every chiller

Photo courtesy of the LTCM lab of the Ecole Polytechnique Fdrale de Lausanne, Switzerland

Reduce refrigerant charges by up to 15% beyond traditional chiller designs with the YVAAs falling-film evaporator and microchannel condenser coil technology.

A more efficient chiller means less electricity generation, which reduces greenhouse gas emissions, water consumption and your environmental footprint. The sustainability advantages of the YVAA chiller give you the opportunity to earn points in the LEED and BREEAM building certification programs.

30/31

Air-cooled VSD screw chiller


YVAA
Application flexibility
Unit Cooling capacity (kW) Full Load Efficiency (EER) Part Load Efficiency (ESEER) Sound power level (dBA) 600 3.2 4.5 96 600 LN 2.9 4.1 92 700 3.2 4.6 98 700 LN 2.9 4.2 93 800 3.2 4.6 99 800 LN 3.2 4.2 94 YVAA 900 900 LN 3.2 3.0 4.6 4.4 99 96 1000 3.2 4.7 102 1000 LN 3.0 4.5 97 1100 3.2 4.7 103 1100 LN 2.9 4.3 98 1200 3.1 4.5 103 1200 LN 3.1 4.3 99

Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12C/7C, ambient temperature 35C Sound Pressure according to Eurovent conditions.

Technical data
Unit Dimensions Operating weight kg Length Width Height mm mm mm 7397 7397 7397 7397 8514 8514 YVAA 8514 8514 2241 2401 8653 8651 9631 9631 10748 9631 10748 11865

6554

6726

7668

7805

8102

8601

8698

9201

9043

9359

9201

9999

YVAA efficiency vs. ordinary chiller


EER 6
Annual hours %

YVAA efficiency & annual energy cost


20 18 16
45,000
Chiller efficiency (ESEER) Annual energy cost

30% 50,000

14 12 10
4

17%

40,000

8 6 4 2
YVAA chiller Ordinary chiller

35,000

30,000

25,000

3
0 25 50 75 100

Chiller load (%)


The YVAA chiller features the industrys highest EER at both design and off-design conditions.

Typical 10-20 year old chiller

Typical chiller today

YVAA Chiller

20,000

YVAA sound values vs. ordinary chiller


dBA reduction Annual hours %

Note: 3500 operating hours, Energy rate = 0.10 EUR/kWh, Cooling capacity = 850kW

0 -2 -4 -6 -8 -10 -12 -14 -16 -18 -20


0 25 50 75 100

20 18 16 14 12 10 8 6 4 2 0

The YVAA chiller exceeds typical chiller ESEER in the market today by up to 17% on a new construction project or up to 30% when replacing an older chiller.

Ordinary chiller YVAA chiller YVAA optimised chiller YVAA optimised chiller with attenuation options

Chiller load (%)


An optimised YVAA chiller can reduce ambient sound by as much as 16 dBA.

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YMWA / YMRA
Water-cooled cooling only, remote condenser and heat pump scroll compressor chiller
Cooling capacities from 20 kW to 190 kW

NEW

Features
Scroll compressors (single or tandem) Higher EER and COP 2 different frames / configurations: 1 compressor / 1 circuit up to 45 kW 2 compressors / 1 circuit from 50 to 190 kW Reduced refrigerant charge Condensing pressure control Plug and Play units Same cabinet w/o or with factory mounted hydrokit (one or two pumps). More compact and slim.

Available versions
14 available YMWA sizes in three versions: 1) YMWA-CO : Cooling only 2) YMRA : Remote condenser 3) YMWA-HP : Heat pump

Nominal capacity and technical data


YMWA-CO Cooling Capacity (kW) EER Length /Width / Height (mm) Operating weight (kg) YMRA Cooling Capacity (kW) Length /Width / Height (mm) Operating weight (kg) YMWA-HP Cooling Capacity (kW) Heating Capacity (kW) EER / COP Length /Width / Height (mm) Operating weight (kg) 20 21.3 4.58 156 20 20.9 144 20 25 26.4 4.54 176 25 26.0 164 25 30 35 40 39.5 4.48 185 40 39.3 172 40 45 46.9 4.57 203 45 46.2 172 45 50 51.1 4.29 440 50 51.2 376 50 60 61.3 4.48 491 60 61.7 404 60 75 77.6 4.48 540 75 77.8 439 75 90 120 150 147.5 4.46 966 150 147.6 762 150 170 170.5 4.50 1041 170 169.4 813 170 190 193.3 4.51 1145 190 193.2 874 190 31.3 35.1 4.46 4.53 821 / 455 / 1350 174 179 30 35 91.4 118.8 4.38 4.46 1210 / 850 / 1500 591 837 90 120

31.3 34.8 821 / 455 / 1350 166 166 30 35

91.4 118.7 1210 / 850 / 1500 466 678 90 120

20.9 26.1 30.3 34.2 38.4 45.8 50.2 59.2 76.4 89.0 115.3 144.8 166.3 186.1 23.5 28.6 33.4 38.2 42.6 50.6 57.2 67.5 85.5 101.2 130.7 162.8 188.3 210.3 4.45/4.03 4.47/4.00 4.28/3.93 4.35/3.96 4.34/3.95 4.39/4.00 4.18/4.03 4.27/3.98 4.38/4.09 4.22/4.06 4.28/4.08 4.35/4.13 4.36/4.11 4.29/4.10 821 / 455 / 1350 1210 / 850 / 1500 159 181 179 184 190 208 448 499 551 602 850 983 1058 1162

YMWA-CO: Standard Eurovent LCP/W/AC conditions in cooling mode: evaporator EWT/LWT 12C/7C, condenser EWT/LWT 30C/35C YMRA: Evaporator EWT/LWT 12C/7C, condensing temperature 40C YMWA-HP: Standard Eurovent LCP/W/AC conditions in cooling mode: evaporator EWT/LWT 12C/7C, condenser EWT/LWT 30C/35C YMWA-HP: Standard Eurovent LCP/W/AC conditions in heating mode: evaporator EWT/LWT 10C, condenser EWT/LWT 40C/45C

Manufacturer reserves the rights to change specifications without prior notice.

32/33

Water-cooled or remote air-cooled screw compressor chiller


Cooling capacities from 134 kW to 320 kW

Features
Efficient screw compressors Highly efficient the YCSE offers the highest standard of reliability and economical operation utilising twin-screw rotor technology and fully modulating compressor slide valve unloading, together with low inrush current star delta starters. To further improve the operating efficiency the leaving liquid temperature can be remotely reset. Quiet operation The compressor has been designed so that there is minimal external gas pulsations and integral oil separators resulting in very low sound and vibration levels. Small footprint and robust design The compact design is ideally suited for reduced base area locations. Both single and twin circuit designs require a single liquid inlet and oulet connection. The unit frame is manufactured from heavy gauge galvanised steel coated with baked-on powder paint.

Options / Accessories
Remote control switch unit. BMS interface. Compressor circuit breakers. Evaporator heater. Flow switch. Differential pressure switches. Suction pressure relief valves. Anti-vibration rubber mounts. Water connection flanges. Discharge and/or suction stop valves. High condenser water temperature and glycol options.

Nominal capacity and technical data


YCSE-SB Model Cooling Capacity (kW) EER Sound pressure at 1 m (dBA) Length /Width / Height (m) Operating weight (kg) At 7C leaving chilled water and 35C leaving condenser water. 40 134 4.00 68 780 50 160 4.00 69 0.85 / 1.1 / 1.5 800 875 1000 60 194 3.95 71 80 232 4.26 71 100 320 4.00 72 1.5 / 1.1 / 1.7 1655

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

YCSE

york air-conditioning products

YCWL
Water-cooled or remote air-cooled scroll compressor chiller
Cooling capacities from 188 kW to 580 kW
Available configurations that meet A Class energy efficiency levels at Eurovent Standard Conditions.

Features
The YCWL series was designed to produce the greatest cooling capacity with the lowest sound levels. The use of scroll compressors provides optimum efficiency at part load, up to an ESEER of 6.92. Its dimensions have been optimized to pass through a doorway 2 m high by 90 cm wide. The YCWL is designed for all air conditioning applications. It is equipped with two independent cooling circuits and regulated by a micro-processor that optimizes chiller performance. The YCWL is designed for indoor installation and each YCWL is fully tested before leaving our factories.

Options
Compressor acoustic blankets Flow switch or pressure differential switch Soft starters Neoprene pads or spring isolators Dual relief valves kit Electronic regulators P.A.C operation water/water up to 50C Vibration isolators

34/35

Water-cooled or remote air-cooled scroll compressor chiller


YCWL 200 to 610
Nominal capacity
YCWL-SE Cooling capacity (kW) 1 EER Energy class ESEER Sound Pressure (dB(A)) 2 YCWL-HE Cooling capacity (kW) 1 EER Energy class ESEER Sound Pressure (dB(A)) 2
200

240 227 4.70 B 6.49 67 230 220 5.05 A 6.31 65 260 248 5.17 A 6.87 67

291 290 4.80 B 6.15 67 301 248 5.03 B 6.38 67 346 352 5.13 A 6.46 70 385 377 5.17 A 6.89 68

346 331 4.77 B 6.20 70 425 410 5.17 A 6.92 71 446 410 5.17 B 6.26 69

395 369 4.78 B 6.50 71 531 520 4.98 B 6.28 71 610 580 4.93 B 6.60 73

188 5.06 A 6.17 64

1 : Cooling capacity at Eurovent conditions, evaporator entering/leaving temperature 12C/7C, condenser entering/leaving temperature 30C/35C. 2 : EN 292-1991 Sound pressure is measured 1 meter away from the control panel and 1.5 meters above the floor. Compressor acoustic blankets fitted.

Technical data
YCWL-SE Dimensions Operating weight YCWL-HE Dimensions Operating weight Length Width Height mm mm mm kg Length Width Height mm mm mm kg
200

240 3191 1749 1759 230 3134 860 1638 1771 1895 1948 1826 1954 260 3153

291 3200 860 2101 301 346 3159 1943 2410 385 3670 911 1972 2707

346 3153 1822 2098 425 3146 860 1892 2204 446

395 3165 1819 2130 531 3670 911 1969 3030 610

3200

2051

3066

2993

Low sound operation


Inside a typical car, 50 km/hr, windows closed

High full and part load efficiences

Sound pressure dB(A)

Normal conversation, 1m away

COP / ESEER

Cooling capacity (kW) Full load efficiency (COP) Part load efficiency (ESEER)

Cooling capacity (kW)

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YLCS
Water-cooled or remote air-cooled screw compressor chiller Heat pump application
Cooling capacities from 342 kW to 1099 kW
Available configurations that meet A Class energy efficiency levels at Eurovent Standard Conditions.

Features
One chiller, many applications Designed to operate with leaving liquid temperatures from -10C to +15C. Efficient compressors YLCS is a dual circuit chiller with industrial type semi-hermetic screw compressors. Star delta compressor starters are incorporated to reduce the inrush current. Outstanding chiller control An advanced microprocessor controller with, a 40 character plain language display, controls and monitors temperatures, pressures, operating hours, number of starts and start stop/holiday times. Fast and easy installation Evaporator water connections can be provided in a vertical or horizontal plain. Electrical power supplies enter from the top for easy drop down wiring.

Options / Accessories
Compressor suction shut-off valves. Companion flange kits. Multi-point power supply. Remote leaving liquid temperature offset. Pressure gauges. Closed transition star delta starters. Power factor correction capacitors. Heat pump control. 90/10 cupro/nickel condenser.

36/37

Water-cooled or remote air-cooled screw compressor chiller


YLCS 350 to 1120
Nominal capacity
YLCS SA Cooling capacity (kW) EER ESEER Sound pressure at 1 m (dBA) YLCS SA Cooling capacity (kW) EER ESEER Sound pressure at 1 m (dBA) At 7C leaving chilled water and 35C leaving condenser water. 350 342 4.2 5.14 74 670 645 4.8 5.58 76 415 411 4.3 5.22 74 750 743 4.8 5.52 76 480 480 4.3 5.25 74 860 849 4.9 5.72 82 530 518 4.3 5.25 77 980 966 5.0 5.83 82 575 556 4.3 5.26 76 1120 1099 5.0 5.79 82 620 604 4.3 5.26 76

Technical data
YLCS SA Dimensions Operating weight kg YLCS SA Dimensions Operating weight kg Length Width Height mm mm mm Length Width Height mm mm mm 350 3225 415 3244 480 3274 900 2100 4170 860 3830 1290 2148 5620 4270 980 3830 530 575 3544 620 3600

3420 670 3565

4030 750 3645

4370 1120 3830

4540

4510

5010

6090

6610

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YVWA
Water-cooled variable speed screw chiller
Cooling capacities from 703 kW to 1055 kW
At Eurovent Standard Conditions this equipment meets A Class energy efficiency levels.

NEW

Features
Our newest water-cooled chiller offers the following benefits: Premium efficiency The YVWA reduces operating expenses with the application of a standard variable speed drive. Application flexibility Tailor and tune flexilibilty makes the YVWA ideal for any application from thermal storage to heat pump duty. Enhanced sustainability Achieved through high efficiency operation and low refrigerant charges. Product confidence Improve your peace of mind knowing our experience stands behind every chiller.

Photo courtesy of the LTCM lab of the Ecole Polytechnique Fdrale de Lausanne, Switzerland

Reduce refrigerant charges by up to 15% beyond traditoinal chiller designs with the YVWAs falling film evaporator design.

The YVWA chiller can efficiently handle the high condenser pressure required for dry cooling.

Photo courtesy of Baltimore Air Coil.

38/39

Water-cooled variable speed screw chiller


YVWA
Nominal capacity (preliminary data)
Unit Cooling capacity (kW) EER 100% ESEER Sound power level (dBA) YVWA 700 5.39 7.64 98 800 5.81 8.28 97 900 5.70 8.39 100 1 000 5.46 7.90 97

Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12C/7C, ambient temperature 35C

Technical data
Unit Dimensions Operating weight (kg) Refrigerant charge (kg) Length Width Height mm mm mm 5 957 245 6 336 245 YVWA 4 268 1 405 1 849 6 412 245 6 260 255

YVWA Efficiency vs. Ordinary Chiller YVWA Efficiency vs. Ordinary Chiller
10

YVWA Energy Cost vs. Ordinary Chiller


250,000

YVWA Energy Cost vs. Ordinary Chiller

YVWA Chiller Ordinary Chiller

Chiller Efficiency (EER)

9 8 7 6 5 4 3 10 15.6 20 17.2 5 30 18.8 10 15

200,000

Annual Hours (%)

150,000 100 ,000 50,000 1 2 3 4

Ord

in

Chi ary

ller

40 20.4

50 22.0

60 23.6

0 70 25.2 80 26.8 90 28.4 100 Chiller Load (%) 30.0 ECWT (C)

YVWA
5 6

Chiller
8 9 10

Years

ECWT = Entering Condenser Water Temperature

Note: 3,500 operating hours, 0.10 EUR/kWh energy rate, 800 kW design cooling load

The YVWA chiller delivers superior energy performance at all operating hours.

An investment in an optimized YVWA chiller reduces energy costs by 25%.

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YN
Water-cooled screw compressor chiller Dry cooler application - Heat recovery application Heat pump application
Cooling capacities from 570 kW to 1300 kW
At Eurovent Standard Conditions this equipment meets A Class energy efficiency levels.

Features
High Efficiency Screw Compressor The open drive twin rotary screw compressor has been engineered and constructed to meet the exact requirements of the industrial refrigeration market. It utilises state-of-the-art technology to provide the most reliable compressor, with high energy efficiency at all operating conditions. Heat Exchangers Shells - The flooded type evaporator and condenser shells are fabricated from rolled carbon steel plates with fusion welded seams. Carbon steel tube sheets, drilled and reamed to accommodate the tubes, are welded to the end of each shell. Intermediate tube supports are fabricated from 12 mm carbon steel plates. Tubes - The copper alloy heat exchanger tubes are externally and internally enhanced to provide optimum performance. Smooth and accurate capacity control Capacity control is achieved by use of a slide valve which provides fully modulating control from 100% to 10% of full load, depending upon the unit selection. The slide valve is actuated by oil pressure controlled by external solenoid valves via the OptiView control centre. Equipped with the optional Solid State Starter, the YN screw chiller starts softly, putting less stress on the motor and compressor, extending their life. In addition, the Solid State Starter includes an impressive array of safety controls that protect the chiller against: phase loss, phase reversal, phase imbalance, under-voltage, overvoltage, and over-current

40/41

Water-cooled screw compressor chiller


YN
Nominal capacity
YN Model Cooling Capacity kW EER ESEER Class EER YN Model Cooling Capacity kW (1) EER ESEER Class EER RB RB S2 RB RD S2 RD RB S2 RD RD S2 RB RB S3 RB RD S3 RD RB S3 RD RD S3 RB RB S4 RB RD S4 RD RB S4 576 5.65 5.88 A 576 5.72 5.94 A 585 5.75 5.98 A 585 5.81 6.03 A 750 5.42 5.68 A 751 5.51 5.75 A 769 5.56 5.82 A 770 5.66 5.89 A 970 5.29 5.72 A 971 5.43 5.82 A 999 5.46 5.89 A

RD RD S4 SA SA S4 SA SD S4 SD SA S4 SD SD S4 RD RB S5 RD RD S5 SA SA S5 SA SD S5 SD SA S5 SD SD S5 1001 5.6 5.99 A 1036 5.9 6.26 A 1037 6.07 6.39 A 1054 6.01 6.37 A 1055 6.19 6.51 A 1231 5.22 5.67 A 1235 5.39 5.82 A 1285 5.74 6.1 A 1286 5.97 6.28 A 1316 5.89 6.23 A 1318 6.13 6.42 A

At 7C leaving chilled water and 32C leaving condenser water.

Technical data
YN Model Length Dimensions Width Height Operating weight kg YN Model Length Dimensions Width Height Operating weight kg mm mm mm mm mm mm 5017 5127 5157 5267 5097 RB RB S2 RB RD S2 RD RB S2 RD RD S2 RB RB S3 RB RD S3 RD RB S3 RD RD S3 RB RB S4 RB RD S4 RD RB S4 3580 1549 2400 5207

5237

5347

5476

5586

5616

RD RD S4 SA SA S4 SA SD S4 SD SA S4 SD SD S4 RD RB S5 RD RD S5 SA SA S5 SA SD S5 SD SA S5 SD SD S5 3580 1549 2400 5726 4211 1676 2500 6919 7408 7160 7649 5787 3580 1585 2410 5897 7090 7579 4211 1700 2500 7331 7820

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YR
Water-cooled screw compressor chiller
Cooling capacities from 730 kW to 1320 kW
Available configurations that meet A Class energy efficiency levels at Eurovent Standard Conditions.

Features
The YORK YR chiller has been designed to match the exact building load and lift requirements, which means it will always operate at peak efficiency when operating at Real World operating conditions. Equipped with the optional Solid State Starter, the YR screw chiller starts softly, putting less stress on the motor and compressor, extending motor life. The semi-hermetic YR chiller is designed for all air conditioning applications The twin rotary screw compressor driven YORK YR chiller is completely factory mounted , including: evaporator, condenser, subcooler, oil separator, compressor, motor, lubrication system, control panel, as well as all interconnecting piping and wiring. Flooded type evaporator and condenser shells are fabricated from rolled carbon steel plates with fusion welded seams.

42/43

Water-cooled screw compressor chiller


YR
Nominal capacity
YR compressor code T0 Shell codes Evaporator TA - TD, VB - VD Condenser TA - TD, VB - VD Leaving chilled water C 6 Leaving cooling water C 30 Cooling capacity kW 730 770 859 905 920 1070 1110 1280 1320

T1

TA - TD, VB - VD, WA - WD

TA - TD, VB - VD, WA - WD

30

T2

WA - WD, XB - XD

WA - WD, XB - XD

30

T3

WA - WD, XB - XD

WA - WD, XB - XD

30

OptiView Panel

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YNWS/RS
Water-cooled or remote air-cooled screw compressor chiller
Cooling capacities from 470 kW to 1790 kW
Available configurations that meet A Class energy efficiency levels at Eurovent Standard Conditions.

Features
The YNWS chiller is designed for all air conditioning applications. Both the water cooled YNWS and the remote air cooled YNRS models are designed for chilled water and process applications. Both models are designed for indoor mechanical room installation. The YNRS requires a cooling tower or an air-water condensing unit for heat dissipation. The screw compressor driven YNWS/RS chiller is completely factory mounted, including: direct expansion (DX) evaporator, condenser, subcooler, oil seperator, compressor, motor, lubrication system, control panel, as well as all interconnecting piping and wiring. R717 Refrigerant

Nominal capacity and technical data


YNWS Model Cooling Capacity (kW) Length /Width / Height (m) Operating weight (kg) YNWS Model Cooling Capacity (kW) Length /Width / Height (m) Operating weight (kg) YNWS Model Cooling Capacity (kW) Length /Width / Height (m) Operating weight (kg) DC FC SO DC GC S0 EC FC S0 EC GC S0 DC FC S1 DC GC S1 EC FC S1 EC GC S1 EC GC S2 EC HC S2 EC JC S2 482 3.7/1.4/1.9 4114 485 3.7/1.4/1.9 4114 511 3.7/1.4/1.9 4114 515 3.7/1.4/1.9 4974 575 3.7/1.4/1.9 4150 579 3.7/1.4/1.9 4540 631 3.7/1.4/1.9 4540 636 3.7/1.4/1.9 5010 809 3.7/1.4/1.9 5449 814 3.7/1.4/1.9 5449 848 3.7/1.4/1.9 5449

FC JC S2 EC HC S3 EC JC S3 856 3.7/1.451.9 6669 1012 3.7/1.4/2.0 6010 1015 3.7/1.4/2.0 6010

EC KC S3 FC HC S3 FC JC S3 1019 3.7/1.4/2.0 6010 1084 3.7/1.4/2.0 6010 1088 3.7/1.4/2.0 6010

FC KC S3 FC KC S4 FC LC S4 FC MC S4 FC NC S4 1093 3.8/1.5/2.3 7335 1347 3.9/1.6/2.3 8412 1352 3.9/1.6/2.3 8412 1354 3.9/1.6/2.3 8412 1395 3.9/1.6/2.3 8412

GC KC S4 GC LC S4 GC MC S4 GC NC S4 FC LC S5 FC MC S5 FC NC S5 GC LC S5 GC MC S5 GC NC S5 1475 3.9/1.6/2.3 8412 1481 3.9/1.6/2.3 8412 1484 3.9/1.6/2.3 8412 1488 3.9/1.8/2.5 10142 1623 3.9/1.7/2.3 9635 1625 3.9/1.7/2.3 9635 1630 3.9/1.7/2.3 10950 1780 3.9/1.7/2.3 10950 1784 3.9/1.7/2.3 10950 1790 3.9/1.8/2.5 10950

At 6C leaving chilled water and 32C leaving condenser water.

Manufacturer reserves the rights to change specifications without prior notice.

44/45

Water-cooled screw chiller


Cooling capacities from 300 kW to 1200 kW
Available configurations that meet A Class energy efficiency levels at Eurovent Standard Conditions.

Features
The YNWH chiller is ideally suited for air conditioning, brine, and industrial applications. The water cooled YNWH is designed for brine based applications. This chiller is designed for indoor mechanical room installation. The YNWH requires a cooling tower or an air-water condensing unit for heat dissipation. The screw compressor driven YNWH chiller is completely factory mounted , including: direct expansion (DX) evaporator, condenser, subcooler, oil seperator, compressor, motor, lubrication system, control panel, as well as all interconnecting piping and wiring. R507 refrigerant

Nominal capacity and technical data


YNWH Model Cooling Capacity (kW) Length /Width / Height (m) Operating weight (kg) 16 12 S0 315 3.7/1.5/1.7 3700 16 12 S1 380 3.7/1.5/1.7 3900 20 20 S2 533 3.9/1.6/2.0 6000 20 20 S3 683 3.9/1.6/2.0 6300 28 24 S4 962 4.3/2.0/2.3 9000 28 24 S5 1169 4.4/2.0/2.3 9800

Cooling capacity at -2/-6C brine application and 32C condenser leaving water temperature

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

YNWH

york air-conditioning products

YMC2
Water-cooled magnetic centrifugal chiller
Cooling capacities from 755 kW to 1340 kW
At Eurovent Standard Conditions this equipment meets A Class energy efficiency levels.

Features
Our most advanced water-cooled chiller offers the following benefits: Enhanced efficiency Achieved through application of active magnetic bearing technology with variable speed drive. Enhanced sustainability Achieved by leak free refrigerant design, lower refrigerant charge and falling film evaporator. Low sound levels Advanced technology results in sound levels as low as 73dBA. Superior reliability Use of active magnetic bearing technology removes friction and the need for oil resulting in a quieter and more reliable chiller.

Photo courtesy of the LTCM lab of the Ecole Polytechnique Fdrale de Lausanne, Switzerland

A falling-film evaporator is more efficient because refrigerant is sprayed over the tubes, offering improved heat transfer and reducing refrigerant charge by 30%.

To eliminate mechanical-contact losses in the driveline, the YMC2 chiller utilises a permanent-magnet motor and active magnetic-bearing technology.

46/47

Water-cooled magnetic centrifugal chiller


YMC2 900 to 1300
Nominal capacity
YMC2 Cooling capacity (kW) EER ESEER Sound pressure at 1 m (dBA) S0900AA 900 6.39 8.32 73 S1000AA 1000 6.44 8.83 73 S1100AA 1100 6.42 9.15 73 S1200AA 1200 6.33 9.40 73 S1300AA 1300 5.94 9.34 73

Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12C/7C, entering/leaving condenser water temperature 30C/35C

Technical data
YMC2 Dimensions Shipping weight (kg) Refrigerant charge (kg) Length Width Height mm mm mm 5340 255 5800 280 S0900AA S1000AA S1100AA 4267 1651 2362 5810 280 S1200AA S1300AA

5810 390

6800 390

NOTES: 1. All dimensions are approximate. Certified dimensions are available on request. 2. Refrigerant charge quantity and shipping weights will vary based on tube count. 3. Shipping weights are based on fully assembled and charged units. 4. Refer to product drawings for detailed weight information.

Superior sound reduction


A-Weighted sound pressure level (dBA (re: 20Pa))
Measured in accordance with AHRI-575

OptiView control centre

Competitor

YORK YMC2
5 dBA*

% Chiller full load


The YMC chiller is so much quieter than competitive magnetic-bearing chillers, it sounds about half as loud. *Note: each segment on the Y axis = 5 dBA.
2

The OptiView control centre provides complete diagnostics to speed troubleshooting.

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YK
Water-cooled centrifugal chiller
Cooling capacities from 800 kW to 11250 kW
Available configurations that meet A Class energy efficiency levels at Eurovent Standard Conditions.

Features
The YORK YK chiller is designed for air conditioning and process applications. The high efficiency single-stage centrifugal compressor is powered by an open-drive motor. This provides flexibility to operate the chiller with electricity, steam, or gas depending on utility rates. The YK utilizes a falling film evaporator to increase chiller efficiency and reduce refrigerant charges, which makes it ideal for LEED building applications. This chiller is designed for indoor mechanical room installation and it requires a cooling tower for heat dissipation The inherent design flexibility of this chiller allows it to be precisely selected for any building load profile.

EER Cooling capacity / power input

Constant speed Variable speed

Cooling capacity

OptiView panel

Speed comparison

48/49

Water-cooled centrifugal chiller


YK
Nominal capacity
Model Code Q3 - Q7 P7 - P9 H9 K1 - K7 K7 & Q3 Cooling capacity kW 800 - 2100 1750 - 2800 2400 - 3800 3200 -9850 8800 - 11250

YK

YK-EP

Cooling capacities at 7C leaving chilled water and 30 C entering condensed water.

Heat Recovery
The YK Heat Recovery option can be used for domestic hot water preheat, process heat, facility air reheat, and humidity control. Heat recovery delivers operational savings, CO2 reductions, and reduced water consumption.

Medium Voltage Variable Speed Drive


YORK has a full line of unit mounted and floor mounted Variable Speed Drives, from 380V to 11,000V, to maximize operational savings at off design conditions; which typically occur 99% of the time!

Quick Start (only available for VSD units)


Utilize Quick Start technology to improve chiller starting times and get back to setpoint up to 70% faster than standard chiller designs!
Total: 10 minutes, 12 seconds

Time for a 1750 kW chiller to return to specified chiller water Setpoint


70% Improve ment

Return to Setpoint

6 minutes 3 seconds

Total: 3 minutes, 2 seconds


Restart 3 minutes 54 seconds 2 minutes 2 seconds 45 seconds Return to Setpoint Restart

Standard chiller

Quick Start feature

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YIA
Single stage hot water or steam powered absorption chiller
Cooling capacities from 280 kW to 3150 kW

Features
YIA chillers are available using low pressure steam or hot water. Compared to electrically driven chillers YIA chillers can dramatically lower system operating costs when using waste heat. Applications particularly well suited to the YORK YIA absorption chiller include cogeneration, waste heat recovery from diesel or gas engine jacket water, turbine air inlet cooling and district heating and cooling installations. Hot water units Hot water units can operate with entering water temperature from 80 to 128C. Steam units Steam units can operate with a steam pressure at generator inlet from 0.2 barg to 0.95 barg. Refrigerant cycle The YORK YIA high efficiency single-stage absorption refrigeration cycle uses water as the refrigerant and lithium bromide as the absorbent. It is the strong affinity and ease of seporation that these two substances have for each other that makes the cycle work. The entire process occurs in hermetic vessels in a near complete vacuum. By using the environmental friendly ADVAGuard 750 inhibitor the internal corrosion rate and hydrogen generation is up to 8 times less than using lithium molybdate. Chiller control The YORK YIA chiller utilizes the OptiView control panel for advanced chiller control and building system integration. Smart Purge is included to eliminate the need for time consuming manual purging of the chiller system.

50/51

Single stage hot water or steam powered absorption chiller


YIA
Nominal capacity
YIA Model Cooling Capacity kW EER (low temperature hot water) YIA Model Cooling Capacity kW EER (low temperature hot water) 1A1 280 0,61 6C4 1145 0,68 1A2 321 0,68 7D1 1253 0,68 2A3 406 0,69 7D2 1415 0,68 2A4 465 0,69 8D3 1535 0,68 2B1 506 0,69 8E1 1885 0,70 3B2 606 0,69 9E2 2090 0,70 3B3 674 0,69 10E3 2265 0,69 4B4 757 0,69 12F1 2675 0,70 4C1 760 0,68 13F2 2940 0,71 5C2 928 0,69 14F3 3150 0,69 5C3 1048 0,61

At 7C leaving chilled water, 95C entering generator water, and 29.4C entering condenser water.

Technical data
YIA Model Length Dimensions Width Height Operating weight kg YIA Model Length Dimensions Width Height Operating weight kg mm mm mm mm mm mm 1A1 3720 1760 4950 6C4 7530 1770 3020 14760 1A2 4330 2320 5500 7D1 6160 2110 17890 6130 7D2 6770 1670 3540 19840 6590 8D3 7530 2110 21800 7900 8E1 6870 2290 3840 24110 26830 29790 35550 8540 9E2 7630 2A3 4940 1420 2A4 5550 2B1 4940 3B2 5550 1580 2640 9490 10E3 10490 12F1 8390 2480 4240 39050 11400 13F2 3B3 6160 4B4 6770 4C1 5550 5C2 6160 1770 3020 12260 14F3 9150 5C3 6770

13620

41140

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

YPC-ST
Two-stage steam fed absorption chiller
Cooling capacities from 1055 kW to 2370 kW

Features
The YORK YPC high efficiency two-stage absorption chiller uses water as the refrigerant and lithium bromide as the absorbent. The YORK YPC chiller is designed for chilled water applications. Product quality, reliability, and service after the sale is evident by having many YORK brand absorption chillers in operation for more than 35 years. ADVAGuard750 is used in YORK absorption chillers to extend chiller life by reducing the corrosion and non-condensable gas generation rates by more than eight (8) times beyond conventional molybdate inhibitors. An automatic refrigerant purge system is utilized to eliminate the need for time consuming manual purging of the chiller.

Nominal capacity and technical data


YPC-ST Model Cooling Capacity (kW) Length / Width / Height (m) Operating weight (kg) 14SC 1055 5.1 / 1.9 / 2.3 11030 16SL 1547 6.0 / 2.3 / 2.6 17150 17S 1705 5.9 / 2.3 / 2.6 17510 18S 2039 7.0 / 2.3 / 2.8 20780 19S 2373 8.0/2.3/2.8 24190

Leaving chilled liquid 7C Entering Tower Water 30C. Entering Steam 8 psi.

Manufacturer reserves the rights to change specifications without prior notice.

52/53

Two-stage direct fired chiller-heater


Cooling capacities from 703 kW to 2370 kW Heating capacities from 565 kW to 1970 kW

Features
YPC-F is designed to provide both chilled or hot water. Both cooling and heating operations, with hot water up to 60C, are performed through the evaporator as standard. Optionally an additional hot water heat exchanger providing hot water up to 79,4C can be installed. With this option a parallel cooling and heating operation is possible. Refrigerant cycle The YORK YPC high efficiency two-stage absorption refrigeration cycle uses water as the refrigerant and lithium bromide as the absorbent. It is the strong affinity that these two substances have for each other that makes the cycle work. The entire process occurs in hermetic vessels in a near complete vacuum. YORKs exclusive two-way split of solution flow allows the unit to operate at much lower solution concentrations and temperatures than in series flow systems. This dramatically increases the efficiency of the unit and virtually eliminates crystallisation problems. By using the environmentally friendly ADVAGuard 750 inhibitor the internal corrosion rate and hydrogen generation is up to 8 times less than using lithium molybdate. Burner YPC-F units can be operated by either natural gas, propane gas or fuel oil. Capacity control is accomplished by modulating the burners firing rate.

Nominal capacity and technical data


YPC-F Model Cooling Capacity (kW) Heating Capacity (kW) Length / Width / Height (m) Operating weight (kg) 12SC 703 563 4.0/1.9/2.3 9490 13SC 809 675 4.0/2.0/2.3 10830 14SC 1055 844 5.0/1.9/2.3 12130 15SL 1231 1013 5.0/2.5/2.7 17360 16S 1407 1125 5.0/2.5/2.7 17580 16SL 1547 1268 6.0/2.6/2.8 21180 17S 1705 1407 6.0/2.6/2.8 21580 18S 2039 1688 7.0/2.7/3.0 25190 19S 2373 1969 8.0/2.7/3.0 29720

Leaving chilled liquid 7C Entering Tower Water 30C. Leaving Hot Water 60C.

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

YPC-F

york air-conditioning products

Central Plant OptimizationTM 10


A facilitys central chiller plant typically uses 20% of the buildings total energy. Managing this load, while still maintaining occupant comfort, is a primary strategy for overall energy management. Johnson Controls Central Plant Optimization 10 (CPO 10) provides such a strategy combining expertise from designing YORK chillers and Metasys controls to save energy and improve reliability in the facility. The application uses tested best practices to select the most efficient combination of chillers, pumps and cooling towers to match the building load. It then commands the selected devices providing the necessary sequencing of pumps, isolation valves and main equipment, while observing safety and stability operation requirements.

54/55

Creating a complex program without programming


The System Selection Tool (SST) is a control program generator that relies on defining the characteristics of the chiller plant and its control strategies. The tool supports selection and sequencing of up to eight chillers of different sizes up to eight (each) primary and secondary chilled water pumps of varying pumping capacities up to eight condenser water pumps cooling towers and bypass valve, including single speed, multi-speed, and vernier control devices that considers user-defined efficiency rating, runtime equalization, and the number-of-starts/number-of-stops equalization Furthermore, control definition for the chiller plant in a single Field Equipment Controller (FEC)/Network Controller Engine (NCE), if supported by available memory and point Input/Output (I/O), or split across multiple FECs/NCEs, is offered.

Flexibility, ready for use


A variety of primary control strategies are also available, including measuring building chilled-water flow and differential temperature chillers kW load flow through a decoupler pipe in a primary/secondary system differential temperature only in a constant speed chilled water pump system It is also possible to select dozens of secondary strategies, such as open loop control of the cooling towers (as defined by the American Society of Heating, Refrigerating and Air-Conditioning Engineers) closed loop control of condenser-water setpoint After making the selections, SST generates a complete program by linking together appropriate software modules. This process removes the variability commonly found in totally custom-generated programs using a traditional software program editor. Once the software modules are linked, the tool allows the entry of all equipment parameters. The resulting program can also be run in a simulator mode to verify proper operation before downloading it into Metasys.

Manufacturer reserves the rights to change specifications without prior notice.

Water Systems

york air-conditioning products

56/57

Air Handling Systems & Terminal Devices


custom & hygienic air handling units fan coil units close control units smartpac - factory packaged controls

york air-conditioning products

So why choose YORK Air Handling Units?


We recognise that your reputation depends on the quality of the products you choose and how well they are installed. Thats why we work hard to make selecting, installing and operating our products as easy as possible. Our YMA range includes a number of additional options that make YORK Air Handling Units the professionals choice.
Factory Packaged controls
Save money and time avoiding to mount controls on-site. Johnson Controls offers YORK Air Handling Units complete with Metasys factory packaged controls so it is ready connect to the site network when it arrives. Our Factory Packaged controls undergo a detailed testing process at the factory to ensure that all wiring is installed correctly, and that all control panels and end devices work appropriately before the AHU is shipped. Factory Packaged Controls option AHUs Metasys factory packaged controls specified option available. Panel Power wiring, Controls wiring and the Variable Speed Drive are included. The pre-engineered controller and required peripheral devices are all supplied factory fitted and tested. Guaranteed compliance with European installation regulations. Simplified final commissioning through the units keypad and display.

Heat-recovery wheels reduce the cost of conditioning supply air.

Energy recovery options


The exhaust air stream from an AHU represents another opportunity to save energy. A heat recovery thermal wheel can economically transfer heat and moisture between the exhaust-air and outside-air paths, reducing the cost of conditioning the supply air. For the simplest form of heat recovery, you can take advantage of free cooling with mixing box sections. During spring and autumn operation, cool/dry outside air cools and dehumidifies the facility, reducing the need for mechanical cooling. Alternatively, you can use recuperative plate heat exchangers. These also allow free cooling in summer by use of face and bypass dampers which by-pass the air around the exchanger so that it is not warmed by the extracted air. We can also offer refrigerant heat pipe and heat recovery coils on your AHU to maximise energy savings.

Reduce fan operating costs


In an AHU, the fan is traditionally the largest source of energy consumption. We can help reduce this by offering a range of energysaving options. High- or premium-efficiency motors can be specified. Direct-drive plenum fans eliminate belt-and-pulley energy losses. If the air system is designed for variable-air volume (VAV), YORK AHUs fitted with variable speed drives offer the most efficient method of VAV fan control. Factory-mounting a variable speed drive reduce jobsite labour costs, unit energy consumption and unit Life Cycle Costs.

58/59

The YORK by Johnson Controls YMA range encompasses our extensive knowledge of air-handling, offering a highly reliable, economical and energy efficient product capable of addressing all of your needs.

Features
The YMA family of air handling units consists of a range of models having air volumes ranging from 0.25 m3/s to 50 m3/s and total static pressures as high as 2000 Pascal: to ensure maximum flexibility and the best solution for your application, units are available in increments of 40mm in height and 50mm in width. YMA Air Handling Units can be manufactured in varied configurations, with a wide selection of components, to meet customer requirements. Units are also available in line with the requirements of hospital sector specifications. Over the past 50 years we have supplied air handling units for: Commercial space: office buildings, cinemas, concert halls Institutional space: schools, universities, churches Industrial manufacturing: automotive, aerospace, chemical, petrochemical Hygienic systems: hospitals, life sciences, R&D facilities, food processing, clean rooms Process manufacturing: pharmaceutical, electronics, semiconductor

Dimensional flexibility. Space constraints are a reality on most


construction projects. YORK AHUs design is based on variable aspect ratios, so the unit can be specified to fit the application and space.

Material flexibility. Different environments require different materials so we offer a number of construction materials, including galvanized steel, pre-coated steel, stainless steel, and aluminium. Component flexibility. To meet any AHU requirement, our units offer every available air-handling component. And as applicable technology creates new capabilities, Johnson Controls will apply this to our product range.

Air Handling Systems & Terminal Devices

Introducing the YMA range of Air Handling Units

york air-conditioning products

YMA
Custom air handling units
A complete range from 0.25 m3/s to 50 m3/s

Features
The YMA family of air handling units consists of a range of models having air volumes ranging from 0.25 m3/s to 50 m3/s and total static pressures as high as 2000 Pascal: to ensure maximum flexibility and the best solution for your application, units are available in increments of 40mm in height and 50mm in width. YMA Air Handling Units can be manufactured in varied configurations, with a wide selection of components, to meet customer requirements. Units are also available in line with the requirements of hospital sector specifications. Units may include combinations of any of the following: - Single or double decked units. - Indoor or outdoor applications - Outdoor units are available with a flat or sloping roof, louvres, rainhoods, birdscreens and special finishes. - Site assembled units. Where space constraints restrict the size of a single item modules can easily be aligned and locked together by gaskets and stainless steel bolts inserted into factory predrilled assembly holes. - Air mixing boxes and various filter options. - Gas fired burners. - Cooling and heating coils. - Humidifiers - Heat recovery systems. - UV sterilising lamps. - Dessicant and thermal wheels. - Sound attenuation. - ATEX Certification. - Factory fitted controls and sensors with YORK SmartPAC Factory Packaged Controls. These include all necessary piping, wiring, controls and refrigeration equipment to provide a complete central air conditioning plant.

Manufacturer reserves the rights to change specifications without prior notice.

60/61

Hygienic Air Handling Units


A complete range from 0.8 m3/s to 60 m3/s

Features
A range of YORK HygienicAir Handling Units, offering unique solutions to the application of Central Station Air Conditioning in a sterile environment. There are many factors affecting air quality, comfort conditions and the efficient operation of Air Handling Units. These include: Mechanical performance Thermal transmission through the Air Handling Unit casing Air leakage Noise transmission Bacteria protection Air cleanliness and filter efficiency Fan and motor efficiency Dehumidification Humidification These factors are valid for the air conditioning of commercial buildings and hotels etc., as well as hygiene sensitive environments such as hospitals, laboratories, clean rooms, food processing and a variety of other process systems. YORK YMA-C AHUS have been specifically designed to address all of these factors: Mechanical performance Thermal efficiency Air leakage and cleanliness

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

YMA-C

york air-conditioning products

YORK Fan Coil units


Driven by innovative trends and modern technology, the YORK Fan Coil Units have been designed around a platform of models, versions and accessories, which have been independently tested and certified by Eurovent. The YORK Fan Coil range meets todays demanding requirements of performance, size, acoustics, low energy, ease of installation and maintenance.

62/63

An extensive offering
One of the most versatile ranges of fan coils on the market today. Wall and ceiling mounted units, exposed or concealed with centrifugal fan, are included, and with cooling capacities ranging from 0.6 kW to 14 kW. Dramatic electrical consumption reduction of up to 40% comparative to previous models. This is achieved thanks to the supply of all YORK Fan Coil Units equipped with centrifugal fans and electric motors, and with 6 speed motors as standard to offer greater flexibility in the selection of products. Energy saving brushless motor technology option available. Its combination with a dedicated frequency inverter and unit controller to regulate the fan speed enables higher efficiencies, even at low rotational speeds, lower unit noise, constant speed characteristics and an increase in motor lifetime expectancy. In comparison to the traditional units equipped with asynchronous three-speedmotors, units with brushless motors can obtain a considerable energy saving, by reducing the power consumption by up to 70%. A full range of factory fitted Johnson Controls valve and pre-configured control options is offered. This in addition to a patented wireless control option - offering greater flexibility in the installation of units, with the highest precision in monitoring and maintaining the desired comfort conditions. High pressure Blower units are also available. They can offer up to 23kw of cooling at External Static Pressures of up to 250Pa, and are complemented with a full range of options and accessories covering items such as electrical heating battery, air inlet/outlet diffusers and condensate pumps.

Iconography

Infrared or Wired control

Wired control

Dry mode

Timer

Auto Restart

Sleep mode

Auto Sweep

Ducted Installation

4 Way Air Flow

Air Filter

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

YFCN Fan Coil Unit centrifugal fan


2 & 4 pipe system
A complete range from 1.0 kW to 7.6 kW

Wired controls
BR Remote three speeds controller TR BR + Electronic thermostat and Summer/Winter switch ATR Automatic TR DTR Digital Automatic Remote controller TMO 503 SV2 Digital Automatic Remote controller to be mounted in the standard light wall box DRC - DI Centralized controller up to 60 terminals

Infrared control

YFCN is a range of Fan Coil Units that continues the YORK tradition based on high reliability and low noise levels. It is the result of great commitment in terms of energy and resources to offer a more modern product from every point of view: every detail has been carefully studied to guarantee the symmetric feet, the wide valve space (170 mm) and easy access to the filter in all models. Moreover each version has the same internal structure, identical in both horizontal and vertical models, in order to standardise production and guarantee a greater flexibility in distribution and installation.

FX03 Terminal unit controller BacNET and N2 Metasys network compatible

Features
New casing, improved aesthetics, suitable for any modern indoor ambient Full range for all needs: 9 sizes suitable for horizontal or vertical mounting with or without casing Wireless control option Low noise operation 3 fan speeds (possible choice between 6 fan speeds) Single piece discharge grid Several coil choices. Single: 3 or 4 rows; Dual: 3 rows cooling & 2 rows heating Electrical heater optional Suction and discharge plenum optional Factory fitted valve (on/off or modulating) and controller packages Painted back panel option 4 available versions in all range: VC = Vertical Discharge with Casing VCB = Vertical Discharge with Casing (floor installation) HC = Horizontal Discharge with Casing CD = Concealed unit without Casing

Selection software

64/65

YFCN Fan Coil Unit centrifugal fan


1.0 to 7.6 kW

Technical features
Model max Total cooling capacity [kW] (1) med min max Sensible cooling capacity [kW] (1) med min max Water flow in cooling [l/h] (1) med min max Pressure drop in cooling [kPa] (1) med min max Heating capacity 2 pipes [kW] (2) med min max Water flow in heating 2 pipes [l/h] * (2) med min max Pressure drop in heating 2 pipes [kPa] (2) med min max Air flow [m3/h] med min max Sound power level [dB(A)] med min max Sound pressure level [dB(A)] Power supply [V-ph-Hz] Power input [W] Absorbed current [A] Height Dimensions Width Depth max max mm mm mm 33 0.16 530 670 225 40 0.18 530 770 225 49 0.23 530 985 225 57 0.26 530 985 225 (3) med min 140 1.23 1.02 0.67 0.97 0.79 0.51 229 189 126 5.6 4 1.9 1.6 1.32 0.84 275 227 144 7.3 5.2 2.4 220 175 105 45 39 32 36 30 23 240 1.81 1.43 1.01 1.38 1.07 0.74 335 265 186 13.9 9.2 4.9 2.25 1.76 1.21 387 303 208 16.7 10.8 5.6 295 220 145 47 40 30 38 31 21 340 2.57 1.89 1.65 1.9 1.38 1.2 475 349 304 11.5 6.7 5.3 3.14 2.28 1.98 540 392 341 13.2 7.5 5.8 385 270 235 49 40 36 40 31 27 440 3.12 2.28 1.83 2.34 1.68 1.34 576 421 339 15.5 9 6.1 3.87 2.79 2.21 666 480 380 18.1 10.2 6.8 485 335 265 47 39 33 38 30 24 540 4.1 3.25 2.2 2.07 2.4 1.6 757 600 404 31.3 20.8 10.4 4.93 3.89 2.58 848 669 444 35.7 23.5 11.4 650 495 315 48 41 31 39 32 22 230 / 1 / 50 + E 61 0.27 530 1200 225 88 0.39 530 1200 225 103 0.47 530 1415 225 130 0.58 530 1415 255 176 0.78 530 1415 255 640 4.8 3.86 2.83 3.6 2.86 2.07 884 714 523 36.2 24.8 14.4 6.05 4.8 3.46 1041 826 595 44.9 29.9 16.8 760 590 415 52 46 37 43 37 28 740 5.58 4.64 3.56 4.23 3.47 2.62 1032 857 657 27.7 20 12.5 6.88 5.68 4.29 1183 977 738 32.8 23.5 14.3 925 735 535 56 51 42 47 42 33 840 6.47 5.73 4.03 5.06 4.43 3.04 1201 1061 746 17.5 14.1 7.6 8.77 7.65 5.23 1508 1316 900 24.5 19.3 9.9 1200 1020 655 60 56 45 51 47 36 940 7.6 6.54 4.88 6.05 5.11 3.72 1410 1213 903 23.2 17.8 10.6 10.53 8.87 6.44 1811 1526 1108 33.8 25 14.3 1500 1210 830 64 58 50 55 49 41

(1) Room temperature 27C d.b., 19C w.b. - Water temperature 7/12 C (2) Room temperature 20C - Water inlet temperature: 50C (3) Sound pressure level in a 100 m2 room, at 1,5 m distance and riverberating time of 0,5 s. * Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397 Data shown is for 4 row cooling version, 2 pipe system. For performance of 3 row cooling version and/or 4 pipe system unit please contact your local Johnson Controls sales office

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

Options / Accessories
Compatibility table / Codes
Model Versions Three speed control BL * Three speed control + electronic thermostat and S/W switch TMV-S Three speed control + electronic thermostat and centralized S/W - TLC ** Automatic speed control with electronic thermostat and S/W switch ATL ** Infra-red remote control with fitted electronic board for versions VC and HC only IRC-M ** IRC-M control (fitted on the unit) with ETN +/- 3% Remote three speed control BR * Remote three speed control + electronic thermostat and S/W switch TR *** Automatic speed control with electronic thermostat and centralized S/W - ATR *** Automatic remote controol with electronic thermostat, S/W swithc and liquid crystall display DTR ** Automatic speed control with electronic thermostat to be mounted in the light wall box TMO-503-S **** Automatic speed control with electronic thermostat to be mounted in the light wall box TMO-503-SV **** Infra-red remote control with NOT fitted electronic board for version CD only IRC-S ** IRC-S control (not fitted on the unit) with ETN +/- 3% Controls for all versions (supplied with separate packaging) Low temperature cut out TME for controls TL, TLC, ATL, ATLC, TR, DTR Low temperature cut out TMM for controls BL, BR Change over 15-25 CH 15-25 Receiving speed selector for centralized control (slave) style VC RECV Receiving speed selectror for centralized control (slave) style HC/CD RECH Receiver (slave) for control DTR RECD Digital remote control up to 60 multifunction units Three speed control BL-E * Three speed control + electronic thermostat and S/W switch BTL-E * Three speed control + electronic thermostat and S/W switch TL-E ** Three speed control + electronic thermostat and centralized S/W - TLC-E ** Automatic speed control with electronic thermostat and S/W switch ATL-E ** Automatic speed control with electronic thermostat and centralized S/W - ATLC-E ** Remote three speed control BR-E * Remote three speed control + electronic thermostat and S/W switch TR-E *** Automatic speed control with electronic thermostat and centralized S/W - ATR-E *** Automatic remote control with electronic thermostat, S/W switch and liquid crystall display DTR ** 3021091 9053048 9053049 9060136 9060137 9060139 9079102 9063000 9063001 9063002 9063003 9063004 9063005 3021091 9053048 9053049 9060136 9060137 9060139 9079102 3021091 9053048 9053049 9060136 9060137 9060139 9079102 VC/VCB mod. - Vertical with casing 9060130 9060140 9060133 9060134 9060175 9060166 Controls for style VC (supplied with separate packaging) 9060175 9060166 9060540 9060541 9060542 9060521 9060170 9060172 9060167 9060166 9060540 9060541 9060542 9060521 9060170 9060172 9060176 9060167 YFCN HC mod. - Horizontal with casing CD mod. - Without casing

Controls for style HC/CD (supplied with separate packaging)

Controls for style VC + additional electric resistance (supplied with separate packaging)

Controls for style HC/CD + additional electric resistance (supplied with separate packaging) 9063050 9063051 9063024 9060521 9063050 9063051 9063024 9060521

* not to be used with valves and/or low temperature cut-out ** it can be used with valves and/or low temperature cut-out *** to be used with valves and/or low temperature cut-out. The Winter/Summer switch is manual/centralized in accordance to the position of the J1 Jumper **** low temperature cut-out included

66/67

Compatibility table / Codes


Model Sizes Valves Kit 3 way valve mounted Kit 3 way valve additional battery mounted Kit 3 way valve not mounted Kit 3 way valve additional battery not mounted Kit 2 way valve primary + additional battery mounted Kit 2 way valve primary battery mounted Kit 2 way valve primary+additional battery not mounted Kit 2 way valve primary battery not mounted Semplified valve kit for CD version fitted Semplified valve kit for CD version not fitted Accessories for all versions Pair feet Vertical auxiliary condensate tray Horizontal auxiliary condensate tray (left connections) Horizontal auxiliary condensate tray (right connections) Condensate drain pipe El. resistance and relays fitted on the unit (650 W) VC/HC El. resistance and relays fitted on the unit (400 W) VC/HC El. resistance and relays fitted on the unit (600 W) VC/HC El. resistance and relays fitted on the unit (750 W) VC/HC El. resistance and relays fitted on the unit (900 W) VC/HC El. resistance and relays fitted on the unit (1000 W) VC/HC El. resistance and relays fitted on the unit (1250 W) VC/HC El. resistance and relays fitted on the unit (1500 W) VC/HC El. resistance and relays fitted on the unit (2000 W) VC/HC El. resistance and relays fitted on the unit (2500 W) VC/HC El. resistance and relays fitted on the unit (700 W) CD El. resistance and relays fitted on the unit (400 W) CD El. resistance and relays fitted on the unit (600 W) CD El. resistance and relays fitted on the unit (750 W) CD El. resistance and relays fitted on the unit (900 W) CD El. resistance and relays fitted on the unit (1000 W) CD El. resistance and relays fitted on the unit (1250 W) CD El. resistance and relays fitted on the unit (1500 W) CD El. resistance and relays fitted on the unit (2000 W) CD El. resistance and relays fitted on the unit (2500 W) CD Damper IM Frame Rear closing panel VC Rear closing panel HC Frontal air intake CD mounted Intake grid for VC Adaptor for terminal board VC for remote control Accessories only for concealed version CD Outlet flange 90 Inlet flange 90 Straight inlet flange Straight outlet flange Outlet spigot diffuser Air outlet grid Air inlet grid Air inlet spigot plenum Intake grid with filter (to be used in combination with inlet flange 90) Intake grid with filter (to be used in combination with straight inlet flange) 9066381 9066441 9066451 9066371 9066361 9066411 9066421 9066461 9066391 9066401 9066382 9060710 9060720 9066372 9066362 9060750 9060760 9066462 9060770 9060774 9066383 9060711 9060721 9066373 9066363 9060751 9060761 9066463 9060771 9060775 9066385 9060712 9060722 9066375 9066365 9060752 9060762 9066465 9060772 9060776 9066387 9060713 9060723 9066377 9066367 9066388 9060714 9060724 9066378 9066368 9060753 9060763 9066468 9060773 9060777 9060150 6060400 6060402 6060403 6060420 9066491E 9066611E 9066531 9062005 9060187 9066501 9060229 9066532 9060575 9060180 9060190 9066502 9060230 9066533 9060576 9060181 9060191 9066503 9060231 9066612E 9066613E 9066592E 9066602E 9066603E 9066605E 9066615E 9066535 9060577 9060182 9060192 9066505 9060232 9060103 9066537 9060578 9060193 9066507 9066593E 9066595E 9066597E 9066607E 9066617E 9066538 9060183 9060194 9066508 9060233 9066492E 9066493E 9066472E 9066482E 9066483E 9066485E 9066495E 9066473E 9066475E 9066477E 9066487E 9066497E 9060151 9066561 9060472 9066560 9060475 9060476 9060478 9066571 9066570 9060477 9060479 9060484 9060481 9060474 9060471
130/140 230/240 330/340 430/440

YFCN
530/540 630/640 730/740 830/840 930/940

9066467

Air Handling Systems & Terminal Devices

Options / Accessories

york air-conditioning products

Dimensions
YFCN 130 to 940 (with casing)

B A 170 158 C 158

630

530

All dimensions in mm. Drawings not a scale. Model A B C 130 / 140 670 225 354 230 / 240 770 225 454 330 / 340 985 225 669 430 / 440 985 225 669 530 / 540 1 200 225 884 630 / 640 1 200 225 884 730 / 740 1 415 225 1 099 830 / 840 1 415 255 1 099 930 / 940 1 415 255 1 099

100

100 71 44 125

133

68/69

YFCN 130 to 940 (without casing)

511

17 12 A 22 22 12 B 153 10 C

511

12

12 29

All dimensions in mm. Drawings not a scale. Model A B C 130 / 140 374 218 354 230 / 240 474 218 454 330 / 340 689 218 669 430 / 440 689 218 669 530 / 540 904 218 884 630 / 640 904 218 884 730 / 740 1 119 218 1 099 830 / 840 1 119 248 1 099 930 / 940 1 119 248 1 099

71 44

125

133

Air Handling Systems & Terminal Devices

Dimensions

119

153

153

york air-conditioning products

ECM Technology
Running costs. Energy consumption. Life cycle. These are 3 issues that are becoming more and more important in the choice of Fan Coil Units. With these criteria in mind, Johnson Controls offers the ECM range of FCU.

ECM technology comprises a brushless motor combined to a dedicated electronic device (inverter). In comparison to conventional units equipped with asynchronous three-speed motors, the fancoil and cassette units with brushless motors can obtain a considerable energy saving, by reducing power consumption up to 70%. Air flow rate can be varied in continuous by means of a 1-10 V signal generated both by our controls or by independent controls systems. The continuous air flow control improves the acoustic comfort and allows a more punctual reply to the variation of the thermal loads, enhancing the stability of ambient temperature.

Technology
ECM technology consists of a brushless motor combined with an inverter managed by specific regulators. The controller uses a modulating signal with 0-10VDC tension to regulate the fan speed. The brushless electric motor is composed of a rotor having permanent magnets, whose magnetic fields interact with the ones produced by the stator winding. The transfer of current is no longer by mechanical commutator (sliding contacts) but by an electronic commutation system: one electronic controller (inverter) powers the motors stator and generates rotating magnetic fields, that in turn determine the rotors speed. Brusless motor develop much less heat than the traditional brushed motors and they have much lower mechanical resistance than the standard asynchronous maintenance. The absence of brushes eliminates also the main source of electromagnetic noise.

Features Brushless motor with inverter. 0-10VDC control signal. Low mechanical resistance and heat gain Continuous regulation of the fan speed. Specifically designed electronic and digital regulators, also for BMS systems. Possibility to manually set the desired three fan speeds (MIN/MED/MAX). Available for fan coil and cassette units.

Advantages (compared to traditional brushed motors)


Energy saving: electrical absorption reduced up to 70%. Higher efficiency: possibility to adapt the air volume and the capacities accordingly to the actual room loads. Higher comfort: reduced variation of the temperature and relative humidity in the room. Extremely quiet operation. Reduced wear and higher reliability. Longer life expectancy of the motor.

Power consumption: YFCN versus YFCN-ECM (W/kW)


YFCN 430 W/kW

YFCN 730 W/kW

YFCN 430 YFCN-ECM 430

YFCN 730 YFCN-ECM 730

2.50 3.50 4.50 5.50

0.50

1.50

2.50

3.50

70/71

YFCN-ECM Fan Coil Unit Inverter with centrifugal fan


0.7 to 7.1 kW

Technical features
Model max 10v Total cooling capacity [kW] (1) med 5v min 1v max Sensible cooling capacity [kW] (1) med min max Water flow in cooling [l/h] (1) med min max Pressure drop in cooling [kPa] (1) med min max Heating capacity 2 pipes [kW] (2) med min max Water flow in heating 2 pipes [l/h] * (2) med min max Pressure drop in heating 2 pipes [kPa] (2) med min max Heating capacity 4 pipes [kW] (3) med min max Water flow in heating 4 pipes [l/h] (3) med min max Pressure drop in heating 4 pipes [kPa] (3) med min max Air flow [m3/h] med min max Sound power level [dB(A)] med min max Sound pressure level [dB(A)] Power supply [V-ph-Hz] Power input [W] Height Dimensions Width Depth max mm mm mm 20.5 530 770 225 20.5 530 770 225 25 530 985 225 25 530 985 225 (4) med min 230 1.61 1.19 0.74 1.3 0.93 0.56 299 220 137 7.9 4.6 2 2.22 1.59 0.95 383 274 163 10 5.6 2.2 1.63 1.23 0.81 140 106 70 4.3 2.6 1.3 330 220 120 51 41 30 42 32 21 240 1.88 1.33 0.78 1.44 0.99 0.57 348 245 145 16.9 9.1 3.6 2.45 1.68 0.96 421 289 165 19.4 10 3.7 325 210 115 51 41 30 42 32 21 430 2.97 2.19 1.42 2.28 1.65 1.04 550 406 262 32.9 19.3 8.9 3.87 2.78 1.74 665 478 300 37.9 21.2 9.3 2.74 2.1 1.47 238 181 126 13.6 8.5 4.5 515 350 210 51 42 30 42 33 21 440 3.19 2.28 1.44 2.48 1.61 1.04 592 421 266 18.5 10.1 4.5 4.04 2.81 1.73 694 484 298 19.5 10.3 4.4 505 340 200 51 42 30 42 33 21 630 3.99 2.94 1.97 3.11 2.23 1.47 738 544 365 21.6 12.6 6.3 5.1 3.7 2.4 879 635 415 24.1 13.6 6.4 3.68 2.8 2 317 241 172 4.5 2.8 1.5 735 495 305 54 44 33 45 35 24 32 530 1200 225 640 4.54 3.2 2.06 3.41 2.35 1.49 839 590 379 37.4 20.2 9.2 5.76 3.96 2.48 991 681 426 41.2 21.3 9.3 720 475 290 54 44 33 45 35 24 32 530 1200 225 730 4.98 3.7 2.61 3.84 2.79 1.93 921 684 4.82 37.1 22 11.9 6.26 4.58 3.15 1077 788 542 40.1 23.2 12 4.63 3.56 2.65 398 306 228 7.8 4.9 2.9 890 610 400 57 48 37 48 39 28 41 530 1415 225 740 5.34 3.84 2.62 4.03 2.84 1.91 987 710 484 29.1 16.3 8.3 6.68 4.72 3.15 1149 812 542 31.2 16.9 8.3 875 585 380 57 48 37 48 39 28 41 530 1415 225 930 6.36 4.86 3.47 5.2 3.83 2.65 1180 900 642 25.4 15.8 8.7 9.13 6.68 4.61 1570 1149 793 34.5 19.9 10.4 5.98 4.62 4 514 397 292 12.3 7.8 4.6 1395 945 605 64 55 44 55 46 35 99 530 1415 255 940 7.14 5.25 3.61 5.63 4.03 2.71 1324 972 669 23.7 13.8 7.1 9.79 6.94 4.63 1685 1194 796 29.8 16.3 8 1365 910 575 64 55 44 55 46 35 99 530 1415 255

230 / 1 / 50 + E

(1) Room temperature 27C d.b., 19C w.b. - Water temperature 7/12 C (2) Room temperature 20C - Water inlet temperature: 50C (3) Room temperature 20C - Water inlet temperature: 70/60C (4) Sound pressure level in a 100 m2 room, at 1,5 m distance and riverberating time of 0,5 s. * Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

LASER & LOW BODY Fan Coil Units


2 & 4 pipe system
A complete range from 0.7 kW up to 9.9 kW

Features
CSL00 (Built in) CSR00 (Wall mounted) Fan speed selector CEL00 (Built in) CER00 (Wall mounted) Thermostat with manual fan speed and automatic change over CEL20 (Built in) CER20 (Wall mounted) Thermostat with auto. fan speed and automatic change over CEL30 (Built in) CER30 (Wall mounted) Thermostat with auto. fan speed and automatic change over for modulating valve

FX03 Terminal unit controller BacNET and N2 Metasys network compatible

6 speed fan Cabinet factory fitted Valve factory fitted Electrical heater factory fitted Thermal or modulating valve Service valve Option front air intake (LASER) Optional plenum (LASER) Up to 110 pa static pressure (LASER)

CML00 (Built in) CMR00 (Wall mounted) Thermostat with manual fan speed and S/W change over

Technical features
Model Sizes Cooling capacity (1) Heating capacity (2) Pressure drop (4) Power supply Input Sound power level (3) Sound pressure level at 3 m (3) Water connections W W kPa V/Ph/Hz W dB(A) dB(A) inch 110 1 169 1 628 3.9 46 49 31 LASER: YLV, YLV-AF, YLH, YLH-AF, YLIV, 112 114 216 218 220 1 746 2 291 3 467 3 804 4 664 2 296 2 981 4 514 5 076 6 013 7.6 6.5 13.8 13.6 23.1 48 50 32 57 53 35 81 53 35 86 55 37 89 55 37 YLIV-AF, YLIH, YLIH-AF 222 224 226 228 5 570 6 789 7 599 9 974 7 304 8 677 9 800 12 739 31.6 18.8 20.9 37.1 230 / 1 / 50 + E 119 145 156 200 59 60 63 67 41 42 45 49 1/2 110 942 1 159 6.1 46 49 31 LOW BODY: YLVR, YLIVR 112 114 216 1 460 2 115 2 719 1 839 2 432 3 270 1.4 5.4 9.1 48 50 32 57 53 35 81 53 35 218 3 372 3 656 24.2 86 55 37

Dimensions indicated next page. (1) Cooling capacities based on 7C EWT t 5C indoor temperature 27C DB / 19C WB (2 pipes - high speed fan) (3 rows). (2) Heating capacities based on 50C EWT (LASER) / 70C EWT (LOW BODY) at nominal flow rate indoor temperature 20C (2 pipes - high speed fan) (3 rows for LASER and 1 row for LOW BODY). (3) Sound level at high speed fan . (4) In cooling mode. For other conditions contact Johnson Controls

72/73

LASER & LOW BODY Fan Coil Units


0.7 to 9.9 kW

Compatibility table / Codes


Model Sizes 110 With Cabinet l YLV-YLH 2/3/4 rows l YLV-YLH/AF Front air intake 2/3/4 rows YLVR 2/3 rows Without Cabinet l YLIV-YLIH 2/3/4 rows l YLIV-YLIH/AF Front air intake 2/3/4 rows YLIVR 2/3 rows Options (Factory fitted) Coil and heaters l 1 row heating BA1 l Kit electrical heater (with relay and safety switch) KREL Built in thermostat Fan speed selector CSL00 Thermostat with manual fan speed CML00 and S/W change over Thermostat with manual fan speed, CEL00 dead band, automatic change over Thermostat with automatic fan speed, CEL20 dead band, automatic change over Thermostat with automatic fan speed, dead band, CEL30 automatic change over for modulating valve Parallel connection For ON/OFF valve one/FCU CBL20 For modulating valve one/FCU CBL30 3 way valve factory fitted For 2 pipe systems ON/OFF J3A2 (2p) For 4 pipe systems ON/OFF J3A2 (4p) 3 way modulating valve factory fitted For 2 pipe systems Modulating J3AM (2p) For 4 pipe systems Modulating J3AM (4p) Shut off valves factory fitted For 2 pipe systems DT (2p) For 4 pipe systems DT (4p) Condensate pump PC WS sensor change over for CEL/CER WS Minimum temperature thermostat TM Accessories (Supplied loose) Remote controllers and thermostat (wall mounted) Fan speed selector CSR00 Thermostat with manual fan speed CMR00 and S/W change over Thermostat with manual fan speed, CER00 dead band, automatic change over Thermostat with automatic fan speed, CER20 dead band, automatic change over Thermostat with automatic fan speed, dead band, CER30 automatic change over for modulating valve Feet and panel (1) l Set of painted feet CP1 l Set of painted feet + frontal socle ZL1 l Vertical painted back panel PPV1 l Horizontal painted back panel PPH1 Plenums and air intake (1) l Air intake plenum PA l Air intake plenum with collars PAS l 90 air intake plenum PA90 l Air intake duct fitting RCA l Air delivery plenum with collars PM l 90 air delivery plenum PM90 112
l l

LASER 114
l l

LOW BODY 222


l l

216
l l

218
l l

220
l l

224
l l

226
l l

228
l l

110

112

114

216

218

l l

l l

l l

l l

l l

l l

l l

l l

l l l l l l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l l l l

l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l l l

l l l l l l

l l l l l l

l l l l l l

l l l l l l

l l l l l l

l l l l l l

l l l l l l

l l l l l l

(1) for check compatibility with the models of FCU see compatibility table

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

Dimensions & Weights


LASER: YLV - YLV/AF
VERTICAL
Dim A B C1 C2 D E F G H I J N O P 110 648 374 224 233 174 100 40 280 101 85 538 266 113 48 87 355 50 117 90 47 28 195 219 205 109 20 18 19 112 773 499 224 233 174 100 40 280 101 85 538 266 113 48 87 355 50 117 90 47 28 195 219 205 109 20 20 21

YLV & YLH V= vertical H= horizontal

YLV-AF & YLH-AF AF= front air intake V= vertical H= horizontal

YLVR R= low body V= vertical

114 898 624 224 233 174 100 40 280 101 85 538 266 113 48 87 355 50 117 90 47 28 195 219 205 109 20 23 24

216 1023 749 224 233 174 100 40 280 101 85 538 266 113 48 87 355 50 117 90 47 28 195 219 205 109 20 28 30

218 1148 874 224 233 174 100 40 280 101 85 538 266 113 48 87 355 50 117 90 47 28 195 219 205 109 20 31 32

220 1273 999 254 263 174 100 40 356 101 85 614 299 138 53 87 409 50 135 116 47 28 238 252 235 122 20 41 43

222 1273 999 254 263 174 100 40 356 101 85 614 299 138 53 87 409 50 135 116 47 28 238 252 235 122 20 44 46

224 1523 1249 254 263 174 100 40 356 101 85 614 299 138 53 87 409 50 135 116 47 28 238 252 235 122 20 52 54

226 1523 1249 254 263 174 100 40 356 101 85 614 299 138 53 87 409 50 135 116 47 28 238 252 235 122 20 52 54

228 1773 1499 254 263 174 100 40 356 101 85 614 299 138 53 87 409 50 135 116 47 28 238 252 235 122 20 58 61

LASER: YLH - YLH/AF


HORIZONTAL

Q R S T U V V1 W X Y Z kg1 kg2

Notes: 1=YLV / YLH - 2=YLV/AF / YLH/AF (All dimensions in mm)

LOW BODY: YLVR

Dim A B C D E G H J N O P Q R S T U V W X Z kg

110 648 374 254 174 100 170 101 430 245 154 31 47 304 88 87 65 47 84 214 109 20 15

112 773 499 254 174 100 170 101 430 245 154 31 47 304 88 87 65 47 84 214 109 20 17

114 898 624 254 174 100 170 101 430 245 154 31 47 304 88 87 65 47 84 214 109 20 22

216 1023 749 254 174 100 170 101 430 245 154 31 47 304 88 87 65 47 84 214 109 20 23

218 1148 874 254 174 100 170 101 430 245 154 31 47 304 88 87 65 47 84 214 109 20 26

(All dimensions in mm)

74/75

YLIV & YLIH V= vertical H= horizontal I= without cabinet

YLIV-AF & YLIH-AF AF= front air intake V= vertical H= horizontal I= without cabinet

YLIVR R= low body V= vertical I= without cabinet

LASER: YLIV - YLIV/AF


VERTICAL

Dim A A1 B C D D1 E F G H I J K L M

110 555 574 374 215 109 128 72 40 280 101 85 505 110 55 349 266 113 48 87 355 50 117 90 47 28 195 219 200 109 20 10

112 680 699 499 215 109 128 72 40 280 101 85 505 110 55 474 266 113 48 87 355 50 117 90 47 28 195 219 200 109 20 13

114 805 824 624 215 109 128 72 40 280 101 85 505 110 55 599 266 113 48 87 355 50 117 90 47 28 195 219 200 109 20 16

216 930 949 749 215 109 128 72 40 280 101 85 505 110 55 724 266 113 48 87 355 50 117 90 47 28 195 219 200 109 20 19

218 1055 1074 874 215 109 128 72 40 280 101 85 505 110 55 849 266 113 48 87 355 50 117 90 47 28 195 219 200 109 20 22

220 1180 1199 999 245 109 128 72 40 356 101 85 581 125 60 974 299 138 53 87 409 50 135 116 47 28 238 252 230 122 20 29

222 1180 1199 999 245 109 128 72 40 356 101 85 581 125 60 974 299 138 53 87 409 50 135 116 47 28 238 252 230 122 20 31

224 1430 1449 1249 245 109 128 72 40 356 101 85 581 125 60 1224 299 138 53 87 409 50 135 116 47 28 238 252 230 122 20 38

226 1430 1449 1249 245 109 128 72 40 356 101 85 581 125 60 1224 299 138 53 87 409 50 135 116 47 28 238 252 230 122 20 38

228 1680 1699 1499 245 109 128 72 40 356 101 85 581 125 60 1474 299 138 53 87 409 50 135 116 47 28 238 252 230 122 20 42

LASER: YLIH - YLIH/AF


HORIZONTAL

N O P Q R S T U V V1 W X Y Z kg

(All dimensions in mm)

LOW BODY: YLIVR

Dim A B C D E G H J K L M N O P Q R S T U V W X Y Z kg

110 555 374 230 108 73 170 101 395 61 349 127 245 154 31 47 304 88 87 65 47 84 214 201 109 20 9

112 680 499 230 108 73 170 101 395 61 474 127 245 154 31 47 304 88 87 65 47 84 214 201 109 20 11

114 805 624 230 108 73 170 101 395 61 599 127 245 154 31 47 304 88 87 65 47 84 214 201 109 20 14

216 930 749 230 108 73 170 101 395 61 724 127 245 154 31 47 304 88 87 65 47 84 214 201 109 20 16

218 1055 874 230 108 73 170 101 395 61 849 127 245 154 31 47 304 88 87 65 47 84 214 201 109 20 19

(All dimensions in mm)

Air Handling Systems & Terminal Devices

Dimensions & Weights

york air-conditioning products

LASER and LOW BODY


Compatibility tables

Features CEL/CER
Dead band for change over 5C or 2C (factory set 2C) Manual fan speeds or automatic (models 20 and 30) Thermostated fan control or continuous fan running Option water sensor WS for change over on coil (for 2 pipes) Led indicated status summer, winter or dead band Temperature setting for 7 to 30C (comfort 20-25C) Plastic pins for limiting temperature range Input for window contact Input for Economy/ occupancy mode Output for remote alarm Filter alarm 600 or 1200 running hours (factory set 1200 hours) With electrical heater post ventilation With Air sensor in the air intake destratification function (CEL only)

CSL00 (Built in) CSR00 (Wall mounted) Fan speed selector

CML00 (Built in) CMR00 (Wall mounted) Thermostat with manual fan speed and S/W change over

CEL00 (Built in) CER00 (Wall mounted) Thermostat with manual fan speed and automatic change over CEL20 (Built in) CER20 (Wall mounted) Thermostat with auto. fan speed and automatic change over CEL30 (Built in) CER30 (Wall mounted) Thermostat with auto. fan speed and automatic change over for modulating valve

Compatibility table Thermostats / Valves / Heaters / Parallel connection / Water sensor / Minimum temperature thermostat
Factory fitted thermostat (built in) CSL00 Fan speed selector CML00 Thermostat with manual fan speed and S/W change over CEL00 Thermostat with manual fan speed, dead band, automatic change over CEL20 Thermostat with automatic fan speed, dead band, automatic change over fan speed, CEL30 Thermostat with automatic modulatingdead band, automatic change over for valve Remote controllers and thermostats (wall mounted) CSR00 Fan speed selector CMR00 Thermostat with manual fan speed and S/W change over CER00 Thermostat with manual fan speed, dead band, automatic change over CER20 Thermostat with automatic fan speed, dead band, automatic change over fan speed, CER30 Thermostat with automatic modulatingdead band, automatic change over for valve
l l l l l l l l l l l l l

Valves for 2 pipes J3A2 (2p)


l l

Valves for 4 pipes J3A2 (4p) J3AM (4p)


l l

Heaters KREL

J3AM (2p)

Parallel connection ON/OFF Modulating CBL20 CBL30


l l

Water sensor WS

Min. Temp. Thermostat TM


l l

Compatible

Not compatible

76/77

LASER and LOW BODY


Compatibility tables

Compatibility Options / Accessories / Models


STANDARD LASER Code Designation YLV YLH YLV-AF YLH-AF YLIV CONCEALED YLIH YLIV-AF YLIH-AF LOW BODY YLVR YLIVR

Coils and heaters** BA1** Additionnal 1 row heating


l l l l l l l l l l l l l l l l l l

KREL** Kit electrical heater with safety thermostat and relay Factory fitted thermostat (built in) CSL00 Fan speed selector (buit in) CML00 Thermostat with manual fan speed and S/W change over CEL00 CEL20 CEL30 CBL20 CBL30 Thermostat with manual fan speed, dead band, automatic change over Thermostat with automatic fan speed, dead band, automatic change over Thermostat with automatic fan speed, dead band, automatic change over for modulating valves Parallel connection for ON/OFF valve Parallel connection for modulating valve

Compatible with electrical heaters Compatible with electrical heaters


l l l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

l l

Remote controllers and thermostats (wall mounted) CSR00 Fan speed selector (wall mounted) CMR00 Thermostat with manual fan speed and S/W change over CER00 Thermostat with manual fan speed, dead band, automatic change over CER20 Thermostat with automatic fan speed, dead band, automatic change over fan speed, dead CER30 Thermostat with automaticmodulating valvesband, automatic change over for
l l l l l l l l l l l l

Compatible with electrical heaters Compatible with electrical heaters


l l

Valves / Condensate pump / Water sensor / Minimum temperature thermostat (Factory fitted) J3A2 (2p) 3-way 4-ports on/off valves for 2-pipe systems J3A2 (4p) 3-way 4-ports on/off valves for 4-pipe systems J3AM (2p) 3-way 4-ports modulating valves for 2-pipe systems J3AM (4p) 3-way 4-ports modulating valves for 4-pipe systems systems DT (2p) Shut-off valves for 2-pipe valves) (in addition to J3A2/J3AM systems DT (4p) Shut-off valves for 4-pipevalves) (in addition to J3A2/J3AM PC WS TM Condensate pump Water sensor Minimum temperature thermostat
l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l

Compatible with CEL/CER


l l l l l l

Feet and panels CP1 ZL1 PPV1 PPH1 Set of painted feet Set of feet + frontal socle Vertical painted back panel Horizontal painted back panel
l l l l l l l l l

External air intake PA PAS PA90 RCA PM PM90


l

Air intake plenum Air intake plenum collars 90 air intake plenum Air intake duct fitting Air delivery plenum with collars 90 air delivery plenum
l l

l l l l l l l l l l l l

Compatible Compatible with conditions Not compatible ** Maximum of rows is indicated in the documentation, the maximum number of rows includes the heating row or electrical heater.

Air Handling Systems & Terminal Devices

york air-conditioning products

YEFB Hydro Blower


2 & 4 pipe system
A complete range from 3.2 kW up to 23.3 kW

CSR00 (Wall mounted) Fan speed selector

CMR00 (Wall mounted) Thermostat with manual fan speed and S/W change over

CER00 (Wall mounted) Thermostat with manual fan speed and automatic change over CER20 (Wall mounted) Thermostat with auto. fan speed and automatic change over CER30 (Wall mounted) Thermostat with auto. fan speed and automatic change over for modulating valve

FX03 Terminal unit controller BacNET and N2 Metasys network compatible

YEFB Blower units are available in 4 sizes for horizontal concealed installations: thanks to their high ESP fans that can handle up to 250Pa, they are the ideal solution for air conditioning large environments.

Features
4 unit sizes for horizontal mounting Handles high external static pressure up to 250Pa Choice of 2 or 4 pipe systems Twin centrifugal fans Horizontal air return Air distribution plenum Electric heater option Optional paint finish F5 grade filter option

Selection software

78/79

YEFB Hydro Blower


3.2 to 23.3 kW

Technical features at 50 Pa external static pressure


Model max Total cooling capacity [kW] (1) med min max Sensible cooling capacity [kW] (1) med min max Water flow in cooling [l/h] (1) med min max Pressure drop in cooling [kPa] (1) med min max Heating capacity 2 pipes [kW] (2) med min max Water flow in heating 2 pipes [l/h] * (2) med min max Pressure drop in heating 2 pipes [kPa] (2) med min max Heating capacity 4 pipes [kW] (3) med min max Water flow in heating 4 pipes [l/h] (3) med min max Pressure drop in heating 4 pipes [kPa] (3) med min max Air flow [m3/h] med min max Sound power level [dB(A)] med min max Sound pressure level [dB(A)] Power supply [V-ph-Hz] Power input [W] Absorbed current [A] Height Dimensions Width Depth max max mm mm mm 186 0.81 331 989.6 800 186 0.81 331 989.6 800 419 1.95 331 989.6 800 419 1.95 331 989.6 800 (4) med min YEFB 130 6.01 5.13 3.22 4.72 3.95 2.38 1033 882 554 6.3 27.4 12.1 8.24 6.87 4.08 1430 1192 708 51.8 37.6 15 13.19 10.98 6.5 1154 961 568 33.1 24 9.5 1153 916 494 67 62 52 57 52 43 YEFB 140 6.92 5.81 3.49 5.29 4.36 2.52 1189 999 600 20.6 15.2 6.2 9.25 7.57 4.3 1604 1313 746 28.3 19.9 7.4 1130 898 484 67 62 52 57 52 43 YEFB 230 8.81 7.27 6.08 7.45 5.9 4.79 1515 1250 1045 70.9 50.5 36.9 13.08 10.34 8.36 2269 1793 1451 116.8 77.2 53.2 21 16.57 13.37 1836 1449 1169 75 49.4 33.9 2158 1553 1174 71 65 60 61 56 50 YEFB 240 10.61 8.55 7.01 8.71 6.74 5.37 1824 1470 1205 43.8 30 21.1 15.44 11.89 9.4 2678 2061 1630 69.7 44 29.1 2116 1523 1151 71 65 60 61 56 50 230 / 1 / 50 569 2.59 350 1 239.6 900 569 2.59 350 1 239.6 900 984 4.45 439.3 1 633 900 984 4.45 439.3 1 633 900 YEFB 330 11.15 9.39 7.51 9.13 7.48 5.81 1916 1615 1291 45.1 33.4 22.5 16.02 13.08 10.1 2779 2268 1752 70.2 49.1 31.2 25.7 20.96 16.17 2247 1833 1414 45 31.5 19.9 2639 1994 1422 71 65 59 62 56 50 YEFB 340 14.06 11.58 9.00 11.2 8.95 6.75 2417 1991 1547 39.6 28.2 18.1 19.76 15.69 11.72 3426 2721 2033 59.2 39.5 23.6 2587 1955 1394 71 65 59 62 56 50 YEFB 430 17.86 16.28 14.40 14.39 12.86 11.57 3071 2798 2475 23.7 20.1 16.1 25.46 22.69 19.55 4414 3934 3390 38.2 31 23.7 41.1 36.66 31.58 3596 3205 2761 24.8 20.2 15.4 4129 3505 2853 78 75 70 69 66 61 YEFB 440 23.31 20.95 18.21 17.73 16.5 13.34 4008 3602 3130 21.9 18.1 14 31.27 27.48 23.26 5421 4765 4032 31.6 25.1 18.6 4048 3436 2797 78 75 70 69 66 61

(1) Room temperature 27C d.b., 19C w.b. - Water temperature 7/12 C (2) Room temperature 20C - Water inlet temperature: 50C (3) Room temperature 20C - Water inlet temperature: 70/60C (4) Sound pressure level in a 100 m2 room, at 1,5 m distance and riverberating time of 0,3 s. * Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397 4 pipe system not available with 4R coil

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

YGFC Fan Coil Unit


2 & 4 pipe system A complete range from 1.9 kW to 14 kW

Commercial Fan Coil Unit range, the YGFC Series is designed specially to meet the varied requirements of zone cooling or heating using chilled water or hot water. However in order to meet the growing demand in city centres where loads are high and space at a premium, YGFC units have a coil option suitable for use in district cooling systems, thus helping reduce pumping power while increasing the overall system efficiency.

Features
10 unit sizes, suitable for horizontal or vertical mounting Models with or without casing 3 speed whisper quiet fans District cooling coil option allows reduction in pump power and increase in system efficiency Single coil 3, or 4 rows Double coil 3 or 4 rows (cooling) & 1 row (heating) Electric heating option Suction and delivery plenum option Range of coil protection options for increased product longevity

Selection software

80/81

YGFC Fan Coil Unit


1.9 to 14 kW

Technical features
Model max Total cooling capacity [kW] (1) med min max Sensible cooling capacity [kW] (1) med min max Water flow in cooling [l/h] (1) med min max Pressure drop in cooling [kPa] (1) med min max Heating capacity 2 pipes [kW] (2) med min max Water flow in heating 2 pipes [l/h] * (2) med min max Pressure drop in heating 2 pipes [kPa] (2) med min max Heating capacity 4 pipes [kW] (3) med min max Water flow in heating 4 pipes [l/h] (3) med min max Pressure drop in heating 4 pipes [kPa] (3) med min max Air flow [m3/h] med min max Sound power level [dB(A)] Power supply [V-ph-Hz] Power input [W] Height Dimensions Width Depth max mm mm mm 37 560 840 263 49 560 940 263 66 560 1040 263 89 560 1122 263 med min 02 ST CB 03 ST CB 04 ST CB 05 ST CB 06 ST CB 07 ST CB 08 ST CB 10 ST CB 2.6 2.5 1.9 1.9 1.8 1.4 410 396 313 19 18.6 14.4 3.09 2.97 2.3 447 428 331 14.3 14 11.3 2.23 2.20 1.91 191 173 166 8.34 8.1 6.3 435 413 296 54 53 45 3.7 3.6 2.8 2.5 2.4 1.9 547 515 513 38.8 37.1 28.9 3.77 3.7 2.9 633 612 479 26.8 25.6 20.2 2.91 2.83 2.44 252 245 209 14.4 13.7 10.5 518 506 370 56 54 47 4.5 4.4 3.3 3.2 3.1 2.4 752 720 544 21.5 18.5 13.2 5 4.8 3.74 785 756 576 18.2 15.7 11.3 3.69 3.54 2.99 316 306 260 23.7 22 16.1 732 691 499 59 57 50 5.3 5.10 4.3 3.8 3.7 3 839 767 619 25.7 23.8 18.7 5.7 5.56 4.58 918 886 734 21.3 19.7 15.6 4.6 4.36 3.63 396 375 313 37.4 33.8 24.1 831 805 620 62 59 53 6.6 6.4 5.1 4.8 4.6 3.6 994 944 752 37.7 36.2 24.9 7.47 7.21 5.66 1145 1094 882 30.8 29.6 20.4 5.64 5.49 4.58 486 472 393 56.6 53.8 38.4 1133 1081 773 64 62 56 120 560 1260 263 7.4 7 5.7 5.5 5.2 4.2 1141 1076 868 25.5 24.5 18.7 8.69 8.28 6.64 1274 1210 990 22 21 16 7.18 6.94 6.02 619 598 518 102 95.6 73.4 1312 1225 904 64 63 58 145 560 1460 263 8.1 7.7 6.4 6 5.7 4.6 1163 1102 896 32.9 29.4 23.5 9.45 9.12 7.39 1390 1328 1101 28.3 25.3 20.1 7.93 7.74 6.74 684 666 580 129 123 94.7 1415 1349 1007 62 60 53 139 560 1560 263 9.2 8.7 7.2 7 6.6 5.3 1512 1411 1159 16.9 15.1 11.8 10.9 10.3 8.3 1584 1498 1238 13.8 12.3 9.3 7.79 7.39 6.2 670 637 533 35.5 32.2 23.2 1714 1599 1176 66 63 55 202 560 1660 263 12 T CB 11 10.5 8.4 8.3 7.8 6.1 1775 1732 1368 25.6 24.2 17.3 12.9 12.3 9.6 1890 1800 1451 21.5 20.2 14.1 9.32 9.15 7.35 809 788 633 53.9 52.1 34.6 2036 1899 1340 66 64 54 214 560 1860 263 14 ST CB 14 13 10.2 10.2 9.5 7.3 2304 2127 1710 44.9 40.6 26.1 15.6 14.7 11.3 2412 2232 1764 37.7 34.1 21.4 11.8 11.3 9.38 1011 972 806 93.1 86.7 61 2399 2220 1548 68 66 61 257 560 2160 263

230 / 1/ 50 + E

(1) Room temperature 27C d.b., 19C w.b. - Water temperature 7/12 C (2) Room temperature 20C - Water inlet temperature: 50C (3) Room temperature 20C - Water inlet temperature: 70/60C * Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397

Minimum Order Quantity applies. Check with your JCI representative.

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

YHK Hydro Cassette


2 & 4 pipe system
A complete range from 1.3 kW to 11.1 kW

Wired controls
BR Remote three speeds controller TR BR + Electronic thermostat and Summer/Winter switch ATR Automatic TR DTR Digital Automatic Remote controller TMO 503 SV2 Digital Automatic Remote controller to be mounted in the standard light wall box DRC - DI Centralized controller up to 60 terminals

Infrared control

Coloured versions available as an option

FX03 Terminal unit controller BacNET and N2 Metasys network compatible

YHK Hydro Cassette units are simple and elegant, discreet in their design. High standards of quality and reliability, combined with a wide range of accessories ensure a total solution for all comfort cooling and heating requirements.

Features
Cooling duty from 1.3 to 11.1 kW 2 & 4 pipes systems in all range 2 sizes: 600 x 600 & 800 x 800 Possible choice between 6 fan speeds Condensate pump integrated in all range 2/3 way valves fitted or supplied loose in all range Coloured versions, possible to change the colour of the grill and the frame Possible to select a complete range of controls Electric heater fitted as an option for all range (2 pipe only) All metal parts insulated to avoid condensations

Selection software

82/83

YHK Hydro Cassette


1.3 to 11.1 kW

Technical features
Model -2 pipes Total cooling capacity 2 Pipes [kW] Sensible cooling capacity 2 Pipes [kW] Water flow in cooling 2 Pipes [l/h] Pressure drop in cooling 2 Pipes [kPa] Heating capacity 2 pipes [kW] Water flow in heating 2 pipes [l/h] * Pressure drop in heating 2 pipes [kPa] Heating capacity 2 pipes [kW] Water flow in heating 2 pipes [l/h] Pressure drop in heating 2 pipes [kPa] Model -4 pipes Total cooling capacity 4 Pipes [kW] Sensible cooling capacity 4 Pipes [kW] Water flow in cooling 4 pipes [l/h] Pressure drop in cooling 4 pipes [kPa] Heating capacity 4 pipes [kW] Water flow in heating 4 pipes [l/h] Pressure drop in heating 4 pipes [kPa] Air flow [m3/h] Sound power level [dB(A)] Sound pressure level [dB(A)] Power supply [V-ph-Hz] Power input [W] Absorbed current [A] Water content (2 pipes) [l] Dimensions (4) (1) (1) (1) (1) (3) (3) (3) max med min max med min max med min max med min max med min max med min max med min max med min max med min max med min max max Height Width Depth mm mm mm (1) (1) (1) (1) (2) (2) (2) (3) (3) (3) max med min max med min max med min max med min max med min max med min max med min max med min max med min max med min YHK 20-2 2.0 1.6 1.3 1.6 1.3 1.0 340 280 219 10 7 4.5 2.6 2.1 1.6 340 280 219 9 6 4 4.6 3.7 2.8 393 315 240 9.9 6.5 4 YHK 20-4 2.3 2.0 1.5 1.9 1.6 1.2 401 337 260 13.5 10 6 3.0 2.5 2.0 261 219 169 14.5 10.5 6.5 610 420 310 49 40 33 40 31 24 44 0.20 8.0 275 575 575 YHK 25-2 2.7 2.3 1.8 2.0 1.8 1.4 461 402 316 9.7 7.6 4.9 3.4 2.9 2.2 461 402 316 8.2 6.3 4.1 5.7 4.9 4.2 488 422 360 8.4 6.4 4.8 YHK 25-4 2.7 2.4 1.9 2.0 1.7 1.3 464 406 318 8.8 6.9 4.6 3.5 3.0 2.4 298 260 209 10.8 8.5 5.7 520 420 310 45 40 33 36 31 24 44 0.20 1.4 275 575 575 YHK 40-2 4.3 3.3 2.3 3.2 2.4 1.6 745 574 387 15.1 9.4 4.6 5.2 3.9 2.6 745 574 387 11.4 7.3 3.5 9.3 7 4.9 795 598 415 12.5 7.6 4 YHK 40-4 3.3 2.7 1.9 2.6 2.0 1.3 574 456 318 13.4 8.8 4.6 4.4 3.5 2.4 378 298 209 16.6 10.8 5.7 710 500 320 53 45 33 44 36 24 68 0.32 2.1 275 575 575 YHK 50-2 5.0 3.9 2.9 3.7 2.8 2.1 863 667 506 19.7 12.4 7.5 6.2 4.6 3.4 863 667 506 17.7 11.2 6.7 10.6 8.3 6.1 914 709 524 16 10 5.9 YHK 50-4 3.8 3.0 2.4 3.0 2.3 1.8 655 519 406 17 11.2 7.2 5.0 4.0 3.1 426 341 267 20.5 13.8 8.8 880 610 430 59 49 41 50 40 32 230V/1ph/50hZ 90 0.45 2.1 275 575 575 YHK 65-2 6.2 4.9 4.2 4.6 3.6 3.0 1 060 845 724 21.6 14.3 10.9 7.8 6.0 5.1 1 060 845 724 15.1 9.9 6.7 13.1 10.7 8.6 1 130 874 741 17.5 11.3 8.4 YHK 65-4 6.3 5.0 4.1 4.7 3.7 3.0 1 090 865 712 18.9 12.5 8.8 9.1 7.2 5.9 783 618 508 21.4 14 9.8 1140 820 630 48 40 33 39 31 24 77 0.36 3.0 303 820 820 YHK 95-2 9.5 6.8 5.3 6.5 4.5 3.5 1 636 1 166 913 26.9 14.7 9.4 11.7 8.0 6.1 1 636 1 166 913 23 12.4 7.9 19.8 13.4 10.3 1 699 1 155 882 20.9 10.6 6.7 YHK 95-4 7.7 5.7 4.5 5.8 4.2 3.3 1 326 974 777 26.9 15.4 10.3 11.0 8.1 6.5 946 697 555 29.9 17.4 11.5 1500 970 710 53 40 34 44 31 25 120 0.53 4.0 303 820 820 YHK 110-2 11.1 8.5 5.3 8.3 6.1 3.7 1 909 1 453 913 35.6 21.8 9.4 14.0 10.3 6.1 1 909 1 453 913 30.6 18.6 7.9 23.7 17.3 10.3 2 037 1 484 882 28.9 16 6.7 YHK 110-4 8.9 6.9 4.5 6.8 5.2 3.3 1 529 1 192 777 34.7 22.1 10.3 12.7 10.0 6.5 1 092 858 555 38.8 25.3 11.5 1 820 1 280 710 58 48 34 49 39 25 170 0.74 4.0 303 820 820

(1) Room temperature 27C d.b., 19C w.b. - Water temperature 7/12 C (2) Room temperature 20C - Water inlet temperature: 50C (3) Room temperature 20C - Water inlet temperature: 70/60C (4) Sound pressure level in a 100 m2 room, at 1,5 m distance and riverberating time of 0,3 s. * Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

YHK-ECM Inverter Hydro Cassette


2 & 4 pipe system
A complete range from 1.8 kW to 10.8 kW

Wired control
ETN-ECM Wall-mounted controller that can be connected allowing an inverter control with a 0-10V signal. The same controller can be connected to one or several cassettes (masterslave function).

Infrared control

FX03 Terminal unit controller BacNET and N2 Metasys network compatible

Coloured versions available as an option

YHK ECM water cassette is the result of significant technical and design research focused on providing an avant-garde product in terms of performance, low noise and control flexibility. YHK ECM series uses an innovative brushless electric motor controlled by an inverter card that varies the air flow continuously by means of a 1-10 V signal. The extreme efficiency, also at a low speed, makes it possible to greatly reduce electrical consumption (more than 75% less in comparison to a traditional motor) with absorption values, under normal operating conditions, that are no greater than 10 Watt in the entire range.

Features
Cooling duty from 1.8 to 10.8 kW YHKH: models with infrared control (standard) YHKY: models with wired control (accessory) 2 (-2) & 4 (-4 or -6) pipes systems 2 sizes: 600 x 600 & 800 x 800 Condensate pump integrated in all range 2/3 way valves fitted or supplied loose in all range Coloured versions, possible to change the colour of the grid and the frame All metal parts insulated to avoid condensations Inverter fan motor for a very quiet operation Electrical consumption reduced by up to 75% Specific range of controllers with master-slave function

Selection software

84/85

YHK-ECM Inverter Hydro Cassette


1.8 to 10.8 kW

Technical features
Model -2 pipes Total cooling capacity 2 Pipes [kW] Sensible cooling capacity 2 Pipes [kW] Water flow in cooling 2 Pipes [l/h] Pressure drop in cooling 2 Pipes [kPa] Heating capacity 2 pipes [kW] Pressure drop in heating 2 pipes [kPa] Model -4 pipes Total cooling capacity 4 Pipes [kW] Sensible cooling capacity 4 Pipes [kW] Water flow in cooling 4 pipes [l/h] Pressure drop in cooling 4 pipes [kPa] Heating capacity 4 pipes [kW] Water flow in heating 4 pipes [l/h] Pressure drop in heating 4 pipes [kPa] Air flow [m3/h] Sound power level [dB(A)] Sound pressure level [dB(A)] Power supply [V-ph-Hz] Power input [W] Water content (2 pipes) [l] Dimensions (4) (1) (1) (1) (1) (3) (3) (3) max med min max med min max med min max med min max med min max med min max med min max med min max med min max med min max Height Width Depth mm mm mm (1) (1) (1) (1) (2) (2) max med min max med min max med min max med min max med min max med min YHK-ECM 25-2 2.8 2.2 1.8 2.1 1.6 1.4 473 373 317 10.1 6.6 4.9 3.4 2.7 2.2 8.7 5.5 4.0 YHK-ECM 25-4 2.8 2.2 1.9 2.1 1.6 1.3 476 375 318 9.5 6.2 4.6 3.6 2.9 2.4 311 245 209 11.7 7.6 5.7 535 380 310 47 39 33 38 30 24 16 1.4 275 575 575 YHK-ECM 40-2 4.3 3.1 2.2 3.2 2.2 1.6 744 524 385 15.1 9.4 4.6 5.2 3.6 2.6 13.1 6.6 3.6 YHK-ECM 40-6 3.9 2.8 2.1 3.0 2.0 1.5 676 483 359 10.5 5.7 3.5 3.4 2.5 2.0 288 217 170 9.0 5.5 3.5 710 445 310 54 43 33 45 34 24 31 2.1 275 575 575 YHK-ECM 50-2 5.0 3.9 2.6 3.7 2.8 1.8 864 666 441 19.7 12.4 5.9 6.2 4.6 3.0 17.7 10.5 4.7 YHK-ECM 50-6 4.5 3.5 2.4 3.5 2.6 1.7 779 608 409 13.1 8.4 4.1 3.8 3.1 2.2 326 263 189 11.0 7.5 4.5 880 610 360 60 50 37 51 41 28 230V/1ph/50hZ 62 2.1 275 575 575 YHK-ECM 65-2 6.3 5.2 4.2 4.7 3.8 3.0 1 089 885 723 22.7 15.6 10.9 8.0 6.4 5.1 19.5 12.8 8.7 YHK-ECM 65-4 6.5 5.3 4.3 4.8 3.8 3.1 1 120 908 740 19.8 13.6 9.4 9.4 7.5 6.1 805 649 528 22.5 15.5 10.5 1 165 870 630 48 39 33 39 30 24 53 3.0 303 820 820 YHK-ECM 95-2 10.8 7.7 5.3 7.9 5.5 3.7 1 848 1 328 909 33.6 18.5 9.4 12.7 8.8 5.9 28.8 14.9 7.2 YHK-ECM 95-6 9.9 7.2 5.0 7.4 5.2 3.5 1 697 1 233 856 30.1 17.0 8.8 9.5 7.2 5.2 818 616 449 18.0 11.0 6.5 1 770 1 130 710 57 47 34 48 38 25 108 4.0 303 820 820

(1) Room temperature 27C d.b., 19C w.b. - Water temperature 7/12 C (2) Room temperature 20C - Water inlet temperature: 50C (3) Room temperature 20C - Water inlet temperature: 70/60C (4) Sound pressure level in a 100 m2 room, at 1,5 m distance and riverberating time of 0,3 s. * Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397

Condensate pump integrated in all sizes

Metal parts insulated to avoid condensation

2 or 3 way valves fitted or supplied loose in all sizes

Outer casing as an option to integrate the water cassette into any enviroment

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

Options & Accessories


Compatibility table / Codes
Model (Panel not included) Cassette YHKY Cassette YHKH - with infrared remote control included Cassette YHKY-ECM - basic model Cassette YHKH-ECM - basic model Options (Factory fitted) Cassette YHKY-E - with electric resistance Version without infrared remote control YHKY-E 2 pipe system Version with infrared remote control included YHKH-E 2 pipe system Cassette YHKY-REB - with remote electric board 2 pipe system Cassette YHKY-REB 4 pipe system Valves 9079510 3 way valve + mounting kit for 2 pipe models (factory fitted) 9079511 9079512 3 way valve + mounting kit for 4 pipe models (factory fitted) 9079513 Accessories (supplied loose) Air diffusers / Panels Air diffuser - intake grid, frame and louvres in RAL 9003 white colour Air diffuser - other colours (*) Valves (220V On/Off) 3 way valve + mounting kit for 2 pipe models (not fitted) 3 way valve + mounting kit for 4 pipe models (not fitted) 2 way valve + mounting kit for 2 pipe models (not fitted) 2 way valve + mounting kit for 4 pipe models (not fitted) 3 way valve + mounting kit for units with outer casing OCA (not fitted) 3 way valve + mounting kit for units with outer casing OCA (not fitted) Other type of valves Other valves Other Accessories Outer casing AKPA 600 AKPA 800
l l -

2 pipe system 4 pipe system 2 pipe system 4 pipe system 2 pipe system 4 pipe system 2 pipe system 4 pipe system

YHK 20 0079100K 0079110K 0079140K 0079150K


-

YHK 25 0079000K 0079010K 0079040K 0079050K 0079801K 0079811K 0079821K 0079831K

YHK 40 0079001K 0079011K 0079041K 0079051K 0079802K 0079812K 0079822K 0079832K

YHK 50 0079002K 0079012K 0079042K 0079052K 0079803K 0079813K 0079823K 0079833K

YHK 65 0079003K 0079013K 0079043K 0079053K 0079804K 0079814K 0079824K 0079834K

YHK 95 0079004K 0079014K 0079044K 0079054K 0079805K 0079815K 0079825K 0079835K

YHK 110 0079005K 0079015K 0079045K 0079055K


-

0079060K 0079080K 0079020K 0079030K


l l -

0079061K 0079081K 0079021K 0079031K

0079062K 0079082K 0079022K 0079032K

0079063K 0079083K 0079023K 0079033K

0079064K 0079084K 0079024K 0079034K


l l

0079065K 0079085K 0079025K 0079035K

0079120K 0079130K

Contact Johnson Controls 9079500 9079501 9079502 9079503 9079505 9079506 9079507 9079508 9079155 9079156
l l l l l l l l l l

Contact Johnson Controls OCA 600 OCA 800 FAD FAK 600 FAK 800
l l l l l

Fresh air duct Fresh air kit 1 way for units with outer casing OCA Fresh air kit 1 way for units with outer casing OCA CONTROLS for YHKY versions Remote three speed control BR 9060540 Remote three speed control + electronic thermostat and 9060541 S/W switch TR Automatic speed control with electronic thermostat and 9060542 S/W - ATR Automatic speed control with electronic thermostat to be 9060172 mounted in the light wall box TMO-503-SV2 Receiver REC-S 9079110 Automatic remote control with electronic thermostat, 9060521 S/W swithc and liquid crystall display DTR Receiver (slave) for control DTR RECD 9060139 Change over CH 15-25 9053049 Low temperature cut out thermostat TME 3021091 CONTROLS for YHKH versions Digital remote control up to 60 multifunction units DRC-DI 9079102 Change over for infrared remote control CH T2 9079103 CONTROLS only for YHK-ECM version Digital remote control up to 60 multifunction units DRC-DI 9079102 ETM-ECM control 3021232 RT03/ECM infrared remote control 9079220 Maxinet management system for a network of cassette fan coil Maxinet 9079104 Board 8 relais for Maxinet 9079105 (*) Minimum order quantity : 20 units

l l

l l l l l l

l l

l l l

l l

86/87

YHK 20/25/40/50-2 / YHK 20/25/40/50-4. (Version 600x600) YHK-ECM 25/40/50-2 / YHK-ECM 25-4 / 40/50-6. (Version 600x600)

All dimensions in mm. Drawings not a scale.

YHK 65/95/110-2 / YHK 65/95/110-4. (Version 800x800) YHK-ECM 65/95-2 / YHK-ECM 65-4 / 95-6. (Version 800x800)

All dimensions in mm. Drawings not a scale.

Air Handling Systems & Terminal Devices

Dimensions

york air-conditioning products

YFCC Coanda Hydro Cassette


2 & 4 pipe system
A complete range from 0.9 kW to 4.0 kW

Wired controls
BR Remote three speeds controller TR BR + Electronic thermostat and Summer/Winter switch ATR Automatic TR DTR Digital Automatic Remote controller TMO 503 SV2 Digital Automatic Remote controller to be mounted in the standard light wall box DRC - DI Centralized controller up to 60 terminals

Infrared control
Thanks to its unique diffuser, YFCC cassette units generate an airflow with a coanda effect. The unit is suitable for installation in a suspended ceiling. Air intake is from the bottom while the air is supplied parallel to the ceiling. The resulting coanda effect creates excellent draft free distribution of the air inside the room. Units can be supplied with 1 coil (2 pipe system) with optional electric heating element, or with 2 coils (4 pipe system) with one or two rows.

Features
Coanda effect units, allowing easier and cheaper installation Cooling duty from 0.9 to 4.0 kW 2 & 4 pipes systems in all range 3 sizes: 600 x 600, 600 x 1000 & 600 x 1200 2/3 way valves fitted or supplied loose in all range Left and right hand (optional) water connections 6 fan speeds (3 pre-wired) Air throw till 7.6m (cooling) and 9.5m (heating)

Selection software Coanda effect

88/89

YFCC Coanda Hydro Cassette


0.9 to 4.0 kW

Technical features
Model -2 pipes Total cooling capacity 2 Pipes [kW] (1) max med min max med min max med min max med min max med min max med min max med min max med min max mm mm mm max med min max med min max med min max med min max med min max med min max med min max med min max mm mm mm YFCC 130 1.5 1.1 0.9 1.2 0.8 0.7 6.1 3.3 2.4 1.9 1.3 1.1 4.9 2.6 1.8 280 180 140 52 41 35 43 32 26 49 309 592 592 YFCC 130+1 1.5 1.1 0.9 1.2 0.8 0.7 6.1 3.3 2.4 1.5 1.1 0.9 3.6 2.1 1.6 280 180 140 52 41 35 43 32 26 49 309 592 592 YFCC 140 1.7 1.2 1.0 1.3 0.9 0.7 12.9 6.7 4.7 2.1 1.4 1.1 10.7 5.4 3.7 280 180 140 52 41 35 43 32 26 44 309 592 592 YFCC 230 YFCC 240 2.4 2.6 1.6 1.7 1.4 1.4 1.8 1.9 1.2 1.2 1.0 1.0 7.6 12.1 3.9 6.0 2.9 4.4 2.9 3.1 1.9 2.0 1.6 1.7 6.3 10.2 3.1 4.8 2.3 3.5 380 380 240 240 200 200 48 48 36 36 33 33 39 39 27 27 24 24 230V/1ph/50Hz 59 49 309 309 592 592 970 970 YFCC 230+1 2.4 1.6 1.4 1.8 1.2 1.0 7.6 3.9 2.9 2.4 1.7 1.5 2.0 1.2 0.9 380 240 200 48 36 33 39 27 24 230V/1ph/50Hz 44 309 592 970 YFCC 330 3.3 2.8 2.0 2.5 2.1 1.4 16.2 12.1 6.4 4.0 3.4 2.3 13.4 9.8 5.2 540 440 290 52 46 35 43 37 26 44 309 592 1 192 YFCC 330+1 3.3 2.8 2.0 2.5 2.1 1.4 16.2 12.1 6.4 3.3 2.9 2.1 4.3 3.4 2.0 540 440 290 52 46 35 43 37 26 59 309 592 1 192 YFCC 340 4.0 3.6 2.5 3.0 2.6 1.8 15.5 12.6 6.7 4.8 4.2 2.9 12.6 10.0 5.5 620 540 360 55 52 41 46 43 32 72 309 592 1 192

Sensible cooling capacity 2 Pipes [kW]

(1)

Pressure drop in cooling 2 Pipes [kPa]

(1)

Heating capacity 2 pipes [kW]

(2)

Pressure drop in heating 2 pipes [kPa]

(2)

Air flow [m3/h]

Sound power level [dB(A)]

Sound pressure level [dB(A)] Power supply [V-ph-Hz] Power input [W] Dimensions Model -4 pipes Total cooling capacity 4 Pipes [kW]

(4)

Height Width Depth

(1)

Sensible cooling capacity 4 Pipes [kW]

(1)

Pressure drop in cooling 4 pipes [kPa]

(1)

Heating capacity 4 pipes [kW]

(3)

Pressure drop in heating 4 pipes [kPa]

(3)

Air flow [m3/h]

Sound power level [dB(A)]

Sound pressure level [dB(A)] Power supply [V-ph-Hz] Power input [W] Dimensions

(4)

Height Width Depth

(1) Room temperature 27C d.b., 19C w.b. - Water temperature 7/12 C (2) Room temperature 20C - Water inlet temperature: 50C (3) Room temperature 20C - Water inlet temperature: 70/60C (4) Sound pressure level in a 100 m2 room, at 1,5 m distance and riverberating time of 0,3 s. * Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

YFCC-ECM Coanda Hydro Cassette Inverter


2 & 4 pipe system
A complete range from 0.8 kW to 4.0 kW

Wired controls
CR-T-ECM Continuous fan speed control with electronic thermostat and s/w switch

ETN-ECM Wall-mounted controller that can be connected allowing an inverter control with a 0-10V signal. The same controller can be connected to one or several cassettes (masterslave function).

Thanks to its unique diffuser, YFCC cassette units generate an airflow with a coanda effect. The unit is suitable for installation in a suspended ceiling. Air intake is from the bottom while the air is supplied parallel to the ceiling. The resulting coanda effect creates excellent draft free distribution of the air inside the room. Units can be supplied with 1 coil (2 pipe system) with optional electric heating element, or with 2 coils (4 pipe system) with one or two rows.

Infrared control

Features
Coanda effect units, allowing easier and cheaper installation Cooling duty from 0.8 to 4.0 kW 2 & 4 pipes systems in all range 3 sizes: 600 x 600, 600 x 1000 & 600 x 1200 2/3 way valves fitted or supplied loose in all range Left and right hand (optional) water connections 6 fan speeds (3 pre-wired) Air throw till 7.6m (cooling) and 9.5m (heating) ECM variable speed motor

Selection software Coanda effect

90/91

YFCC-ECM Coanda Hydro Cassette Inverter


0.8 to 4.0 kW

Technical features
Model -2 pipes Total cooling capacity 2 Pipes [kW] (1) max med min max med min max med min max med min max med min max med min max med min max med min mm mm mm max med min max med min max med min max med min max med min max med min max med min max med min mm mm mm YFCC-ECM 130 1.6 1.2 0.8 1.2 0.9 0.6 6.5 4.0 2.1 2.0 1.5 1.0 5.3 3.3 1.7 295 205 130 55 46 35 46 37 26 309 592 592 YFCC-ECM 140 1.8 1.3 0.9 1.4 1.0 0.7 13.9 8.1 4.1 2.2 1.6 1.1 11.6 6.6 3.3 295 205 130 55 46 35 46 37 26 309 592 592 YFCC-ECM 230 YFCC-ECM 240 3.2 3.5 2.3 2.5 1.5 1.6 2.4 2.6 1.7 1.8 1.1 1.1 12.6 20.8 7.3 11.6 3.2 5.0 3.9 4.3 2.8 3.0 1.7 1.8 10.4 17.1 6.0 9.4 2.6 4.1 540 540 370 370 215 215 56 56 46 46 34 34 47 47 37 37 25 25 230V/1ph/50Hz 309 309 592 592 970 970 YFCC-ECM 230+1 3.2 2.3 1.4 2.4 1.7 1.1 12.6 7.3 3.2 3.0 2.3 1.6 3.1 2.0 1.0 540 370 215 56 46 34 47 37 25 230V/1ph/50Hz 309 592 970 YFCC-ECM 330 3.8 2.8 1.9 2.8 2.1 1.4 19.8 11.7 5.8 4.5 3.3 2.2 16.6 9.4 4.7 620 430 275 58 48 36 49 39 27 309 592 1 192 YFCC-ECM 340 4.0 2.9 2.0 3.0 2.2 1.4 15.5 8.9 4.3 4.8 3.4 2.3 13.0 7.4 3.5 620 430 275 58 48 36 49 39 27 309 592 1 192

Sensible cooling capacity 2 Pipes [kW]

(1)

Pressure drop in cooling 2 Pipes [kPa]

(1)

Heating capacity 2 pipes [kW]

(2)

Pressure drop in heating 2 pipes [kPa]

(2)

Air flow [m3/h]

Sound power level [dB(A)]

Sound pressure level [dB(A)] Power supply [V-ph-Hz] Dimensions Model -4 pipes Total cooling capacity 4 Pipes [kW]

(4)

Height Width Depth

(1)

Sensible cooling capacity 4 Pipes [kW]

(1)

Pressure drop in cooling 4 pipes [kPa]

(1)

Heating capacity 4 pipes [kW]

(3)

Pressure drop in heating 4 pipes [kPa]

(3)

Air flow [m3/h]

Sound power level [dB(A)]

Sound pressure level [dB(A)] Power supply [V-ph-Hz] Dimensions

(4)

YFCC-ECM 130+1 1.6 1.2 0.8 1.2 0.9 0.6 6.5 4.0 2.1 1.5 1.2 0.9 3.8 2.5 1.4 295 205 130 55 46 35 46 37 26 309 592 592

YFCC-ECM 330+1 3.8 2.8 1.8 2.8 2.1 1.4 19.8 11.7 5.8 3.6 2.8 2.0 5.1 3.3 1.8 620 430 275 58 48 36 49 39 27 309 592 1 192

Height Width Depth

(1) Room temperature 27C d.b., 19C w.b. - Water temperature 7/12 C (2) Room temperature 20C - Water inlet temperature: 50C (3) Room temperature 20C - Water inlet temperature: 70/60C (4) Sound pressure level in a 100 m2 room, at 1,5 m distance and riverberating time of 0,3 s. * Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

Options & Accessories YFCC / YFCC-ECM


Compatibility table / Codes
Model (Panel not included) Cassette YFCC 2 pipe system 4 pipe system (+1) 4 pipe system (+2) 2 pipe system 4 pipe system (+1) 4 pipe system (+2) YFCC 130 0064001K 0064021K 0064041K 0064201K 0064221K 0064241K YFCC 140 0064011K 0064031K
-

Cassette YFCC-ECM Options (Factory fitted) Right hand connection Valves (220V On/Off) (factory fitted)

0064211K 0064231K
-

YFCC 230 0064002K 0064022K 0064042K 0064202K 0064222K 0064242K

YFCC 240 0064012K 0064032K


-

0064212K 0064232K
-

YFCC 330 0064003K 0064023K 0064043K 0064203K 0064223K 0064243K

YFCC 340 0064013K 0064033K


-

0064213K 0064233K
-

Contact Johnson Controls

3 way valve + mounting kit for 2 pipe models (factory fitted) 3 way valve + additional battery (factory fitted) 2 way valve + additional battery (factory fitted) Controls Infrared control Accessories (supplied loose) Valves (220V On/Off) 3 way valve + mounting kit for 4 pipe models (not fitted) 3 way valve + additional battery not fitted 2 way valve + additional battery not fitted Other type of valves Other valves Wired controls Remote three speed control BR Remote three speed control + electronic thermostat and S/W switch TR Automatic speed control with electronic thermostat and S/W - ATR Automatic remote control with electronic thermostat, S/W swithc and liquid crystall display DTR Automatic speed control with electronic thermostat to be mounted in the light wall box TMO-503-S Automatic speed control with electronic thermostat to be mounted in the light wall box TMO-503-SV2 Remote thermostat with S/W switch (for 2 pipe system only) Continuous fan speed control with electronic thermostat and s/w switch CRT-ECM Power unit for CR-T-ECM remote control, fitted on the unit UPM-ECM Power unit for CR-T-ECM remote control, not fitted on the unit UPS-ECM Wall-mounted control (to be used only with IR-ECM) ETN-ECM Receiver REC-S Receiver (slave) for control DTR RECD Low temperature cut out thermostat TME Low temperature cut out thermostat TMM Change over CH 15-25 Infrared and Free controls Infrared remote control with not fitted electronic board for versions CD only IRC-S IRC-S control (not fitted on the unit) with ETN +/-3% Infrared remote control with receiver (to be used only with IR-ECM), not fitted on the unit RT03/ECM-S Control board fitted on the unit IR-ECM-M Control board not fitted on the unit IR-ECM-S Low temperature cut out CH Digital remote control up to 60 multifunction units Maxinet Board 8 relais for Maxinet Remote control FREE-COM Free control Not mounted Electronic board FREE-UPS Temperature sensor FREE-SEN Low temperature cut out FREE-NTC 9060478 9060479 9060476

9066561
-

9060471 9060472 Contact Johnson Controls

9060175 9060166

9066560
-

9060474 9060475 Contact Johnson Controls Contact Johnson Controls

Contact Johnson Controls

9060540 9060541 9060542 9060521 9060170 9060172 9060174 9066342E 9066341 9066340 3021232 9079110 9060139 3021091 9053048 9053049

9060176 9060167 9066327 9066326 9066325 9079103 9079102 9079104 9079105 9060572 9060571 9060570 9060573 3021090

92/93

Diffussers
A
A
A

All dimensions in mm. Drawings not a scale.

YFCC / YFCC-ECM 130 to 340


298 E 309

E 72 F F 100 592

All dimensions in mm. Drawings not a scale.

Model A E F

130 / 140 592 454 78

230 / 240 970 884 43

330 / 340 1 192 1 099 46.5

Air Throw
C1 - Heating C2 - Cooling

L
YFCC 3 5.8 4.6 1 4 6.3 5 YFCC 3 6.1 4.8 2 4 7 5.6

L
YFCC 3 6.3 5 3 4 7.5 6

Model Air throw L (m) C1 C2

1 3.8 3

2 4.5 3.6

5 6.8 5.4

6 7.2 5.7

1 4 3.2

2 5 4

5 8 6.4

6 9 7.2

1 4.5 3.6

2 5.2 4.1

5 8.8 7

6 9.5 7.6

Air Handling Systems & Terminal Devices

Dimensions

592

592

592

york air-conditioning products

YHM Hydro High Wall


2 pipe system
A range from 1.7 to 4.7 kW

Features
Wired control or infrared control Automatic air sweep 3 way valves fitted (YHMH 20V and 30V models) or 2 way valves supplied loose in all range Condensate collection tray Air filter included Heat exchange coil

Wired control (YHMY)


4 operation modes (Cool/Heat/Auto/Fan) Room temperature and setting Fan speed selector (Auto, low, medium and high)

TR. Wired Control Remote three speeds controller, electronic thermostat and Summer/Winter switch ATR. Wired Control Automatic TR

Infrared control (YHMH)


Wireless 5 operation modes (Cool/Heat/Auto/Dry/Fan) Sleep Mode Room Temperature setting Fan speed selection Timer Air flow direction setting LCD display

Electronic Infrared Control

2 Way Valve ON/OFF with thermoelectric actuator. Suitable for the connection with 12 mm pipes

FX03 Terminal unit controller BacNET and N2 Metasys network compatible

Rear Frame for installation of valves (accessorie)

94/95

YHM Hydro High Wall


1.7 to 4.7 kW

Technical features
Model Cooling capacity Sensible capacity Heating capacity Air flow Electrical data Power supply Power input Noise level Sound pressure level at 1 m Dimensions and weight Height Width Depth Weight mm mm mm kg 270 845 180 10 270 845 180 10 298 920 200 13 298 920 200 13 dB(A) 36 / 33 / 29 43 / 33 / 30 46 / 43 / 39 51 / 47 / 44 V/Ph/Hz W 230 / 1 / 50 + E 24 28 40 50 kW kW kW m3/h YHMY(H) 20 2.2 / 1.9 / 1.7 1.8 / 1.6 / 1.5 2.7 / 2.3 / 2.0 436 / 376 / 334 YHMY(H) 30 2.8 / 2.0 / 1.8 2.5 / 1.8 / 1.6 3.6 / 2.6 / 2.2 632 / 522 / 403 YHMY(H) 40 4.0 / 3.4 / 3.1 3.4 / 2.9 / 2.6 4.9 / 4.2 / 3.8 780 / 691 / 570 YHMY(H) 50 4.7 / 3.9 / 3.4 3.6 / 3.3 / 2.9 5.8 / 4.9 / 4.2 920 / 810 / 697

Technical features with valve fitted


Model Cooling capacity Sensible capacity Heating capacity Air flow Electrical data Power supply Power input Noise level Sound pressure level at 1 m Dimensions and weight Height Width Depth Weight mm mm mm kg 270 845 180 11 298 920 200 13 dB(A) 44 / 38 / 32 50 / 43 / 38 V/Ph/Hz W 230 / 1 / 50 + E 50 60 kW kW kW m3/h YHMH 20 V 1.7 / 1.6 / 1.2 1.3 / 1.1 / 0.9 2.4 / 2.0 / 1.7 450 / 383 / 323 YHMH 30 V 3.2 / 2.8 / 2.4 2.4 / 2.1 / 1.8 4.5 / 3.9 / 3.4 650 / 560 / 490

All data are in high/medium/low speed Cooling capacities based on 7C EWT t 5C Indoor temperature 27C DB / 19C WB Heating capacities based on 50C EWT at nominal flow rate Indoor temperature 20C Water flow rate as for the cooling conditions

Codes
Unit without infrared remote control Unit codes Unit with infrared remote control Unit codes Unit with infrared remote control and fitted valve Unit codes Options (Factory fitted) / Accessories (supplied loose) TR (Wired ON/OFF 3 Speeds Cool/Heat) ATR (TR + Auto speed control) 2 Way valve Rear frame Rear frame with 3 way valve Low temperature cut out Change over 9060541 9060542 9024000
l l l l l l l l l l l l

YHMY 20 0024231K YHMH 20 0024241K YHMH 20 V 0024252K

YHMY 30 0024232K YHMH 30 0024242K YHMH 30 V 0024254K

YHMY 40 0024233K YHMH 40 0024243K -

YHMY 50 0024234K YHMH 50 0024244K -

9024021 9024031 3021091 9053049


l l l l l l

9024023 9024033
l l

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

YORK Close Control units


Maintaining a constant temperature, purity and humidity of air is essential for ensuring a stable environment for critical electronic and computer equipment, this is why there is the need for close control air conditioning. Unlike comfort air conditioning, close control systems must operate constantly 24/7 requiring high reliability and minimal power consumption. Johnson Controls knows that no two close control requirements are the same, this is why the YORK range of custom close control units offers quiet, compact and energy efficient equipment that can be configured to needed requirements.

96/97

An extensive offering
cooling capacities of up to 220kw (chilled water) or 100kw (direct expansion) with optional free cooling models. Up flow or down flow configuration, either as self-contained packaged units or suitable for connection to remote condensers, are also available optional direct expansion units fitted with scroll compressors, which have much lower noise and energy consumption than reciprocating compressors R410a refrigerant units available optional Free Cooling coil to reduce energy consumption required through use of mechanical cooling plug fan with Electronically Commuted EC fans option, to allow fully modulating control of airflow low component face velocities, for a lower total pressure drop and reduced energy consumption minimised dimensions, enabling one of the markets greatest ratios between sensible cooling capacity and base foot print

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

YORK YC-P Series Close Control Air Conditioners


A complete range from 6.6 kW up to 200 kW

High energy efficiency and minimum environmental impact


P Series air conditioners for close control applications are specialised machines with design and operating features which clearly differentiate them from standard air conditioning units. The P Series air conditioners offer very high energy efficiency values in all operating conditions which translates into less CO2 emissions and particularly low running costs. Though optimised for use in data centers and telephone exchanges, they are equally valid in special applications such as measurement laboratories, TV recording studios, museums, control rooms for electricity power stations and railway junctions and other areas where there are prevalent sensible thermal loads and crowding is negligible. Their application is also ideal in widely varied industrial sectors: optics, electronics, electromedical equipment, electronic equipment production, musical instrument production etc.

Optimal efficiency
Johnson Controls P Series design offers the highest sensible cooling capacity with the minimum footprint possible, which translates into optimal ratio levels of cooling capacity to footprint area. This is an important feature in reducing the space needed by machinery, allowing more room in the space for IT equipment. This advantage is especially important given the progressive increases in capacity required by data centers and other computer applications which, over time, need the addition of extra air conditioners. Clean efficiency is also ensured by the use of the R-410A refrigerant, respectful to the ozone layer.

98/99

Features and performance


Silent operation and high energy efficiency
The scroll compressors of YORK YC-P Series air conditioners with direct expansion coil are quieter than conventional reciprocating compressors. Scroll compressors have a much lower energy consumption than reciprocating compressors. The cooling coils of the downflow units (YC-UP), both in chilled water and direct expansion versions, have aluminium fins with a hydrophylic treatment that alleviates the risk of condensation and the coil face being covered with water, which would compromise the thermal performance and therefore the air conditioning capacity. The aluminum fins have specialisation of the TURBO/ COIL profile, perfected in the LU-VE SpA research labs. They produce a predetermined turbulence of the crossing air which therefore increases the coefficient of heat exchange. The use of the environmentally friendly refrigerant HFC R410A does not contribute to the depletion of the ozone layer (R134a available on request). Thanks to its larger surface area, the filter on the coil allows lower face velocity, which results in lower pressure drop. The lower energy consumption of these air conditioners, at the same efficiency, results in a much reduced TEWI (Total Equivalent Warming Impact). The application of EC plug fans reduces both energy consumption and noise levels.

Microprocessor regulation
The Standard digital microprocessor allows management of all typical air-conditioning functions: cooling, heating, humidification, dehumidification and filtering ensures a regular and optimised operation as to both performance and consumption, providing as well alarm management and selfdiagnosis in case of need to install any component requiring analogue control (modulating valve or electronic hot-gas by-pass valve), an optional modulating controller, with semigraphic display, shall be installed in lieu of standard. This alternative controller is also installed as standard microprocessor on special versions such as Free cooling, Two Sourcesand Fresh air units.

Local network management or remote control


YORK YC-P Series air conditioners are capable of standalone operation, local private network with multiple units (up to 12) or fully integrated with Metasys Building Management System from Johnson Controls. In local network applications, one machine is the master, and the remaining slaves follow the same algorithm. The slave units are rotated at predetermined intervals and switch to the master role to balance the number of working hours of the compressors. In remote applications, the machines can be controlled from remote positions interfacing with common Building Management Protocols such as BacNET, LON and Modbus, either via GSM Modem or TCP/IP Internet Protocol. For total integration with Johnson Control Metasys Building Management Systems (BMS) the units can be equipped with an RS485 card working with BacNET MS/TP protocol.

Downflow unit with 2 fans and side compartment; full front access for both fans (covered) and technical compartment

Cooling circuit
The air conditioners with direct expansion coil have a frigorific circuit equipped with: scroll compressor with all necessary protective devices, high pressure (manual reset) and low pressure (automatic reset) switches, thermal expansion valve, dehydrating filter with refrigerant sight glass. YC-OPA, YC-UPA models for pairing with remote condensers, are already equipped with a pressurisation nitrogen charge. The refrigerant charge, and the oil top-up (if required), shall be made by the installer on site. YC-OPA and YC-UPA air conditioners in self-contained packaged format with built-in water-cooled condensers (accessory), are supplied with full refrigerant and oil charge.

Downflow unit with 2 fans and side compartment; full front access for both fans (not covered) and technical compartment on the side. No side maintanance space is required for accessing components

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

Electronic expansion valve (*)


Electronic expansion valves are one of the most recent pieces of equipment that enable us to improve the energy efficiency at partial loads of direct expansion machines. These valves are installed at the inlet of the evaporator, substituting the traditional thermostatic expansion ones: this allows more precise control of the quantity of refrigerant entering the evaporator, and guarantees good capacity regulation, typically between 100% and 50%. Electronic expansion valves also allows control of the amount of overheated gas at the outlet of the evaporator, thus allowing a significant reduction of the condensation pressure during winter or night-time operation whilst maintaining the evaporation pressure unchanged. Adoption of the electronic expansion valve (optional) guarantees a significant increase of the EER values.

Control Panel
All the units are equipped with a complete control panel with main isolator switch. Magnetothermic switches, contactors, and all necessary protection is provided, as required by legal codes and standards. The control panel of the units equipped with compressors (A as third letter of the identification code) has as standard a phase sequencer, which prevents the compressor from getting damaged when counter running. Also, the control panel has two spare terminals for remote indication of a cumulative alarm, as well as two terminals for starting up and stopping the unit from remote position. The control panel does not include the fan speed controller(s) for the fans of the air cooled remote condensers (winter control). This device is included as standard in the CEA and CEA/LN air cooled condensers from Johnson Controls. Should you decide to match the unit with a condenser from another manufacturer, the controller(s) can be ordered as accessory.

One or two completely independent compressors


Models with 1 as the last digit of the unit model number have a single circuit and a single compressor. Those with 2 as the last digit on the other hand have two completely independent refrigerant circuits and two compressors. The circuits are fitted with all the safety and regulation devices necessary for efficient and reliable operation. The evaporator coil can be single or double circuit depending on the number of compressors.

Hydraulic circuit
Air conditioners with chilled water coil, YC-OPU and YC-UPU, include a finned coil and a three-way throttling motorised valve for water flow regulation. The hydraulic circuit is provided with copper tubes with anti-condensate insulation. The coils are optimised for both water with a temperature of 7/12 and for higher ones such as 15/20. The standard throttling valve (3 points) allows good modulation of the cooling capacity as a function of the environmental conditions, especially with constant thermal loads.

Modulating controller display and keypad

Large surface filters


The units are equipped with self-extinguishing media class G4 filters. The filters are installed inclined before the cooling coil in order to offer a larger surface and allow lower air crossing speeds, with lower energy consumption. A 450 mm high duct (accessory) can be installed for holding a F7 class filter, vertically on supply air discharge.

Modulating regulation of the cooling capacity (**)


If a very precise regulation and high response speed are required, a modulating valve (optional) can be installed in lieu of the throttling one. The installation of this valve is recommended in case of functionment with a lot of fresh air. However, the modulating valve needs an analogue signal, not digital, so the installation of the optional modulating controller is necessary.

Design suitable to civil environments


YORK YC-P Series air conditioners have a pleasant and functional design, suitable for installation in civil environments. Their structure consists of aluminium profiles and closing panels hinged on them. Both panels and profiles are coated with a dark grey PVC layer (anthracites), thermoacoustically insulated by polyurethane layer, and further coated with an anti scratch plastic film. Two versions are available for up flow units (YC-OP): front grille & top air discharge (standard), or blind front panel, suction from the bottom and top discharge (optional).

(*) units equipped with frigorific circuit (**) units equipped with chilled water coil

100/101

Fan section
Standard fans
The standard fan section is made up by one or more backward curved, free running impeller, radial fans (plug fan) with single speed motors which offer a particularly low noise level as well as a high efficiency. The free running impeller assures a very high efficiency and an easy cleaning of the blades too. These fans offer a high available static pressure, perfect for most applications. The final air flow comes as a consequence of the real pressure drop of the installation; anyhow it can be calculated through our selection software. Standard fans with AC motors have two operating speeds and therefore two different airflows and static pressures, which can be selected through their terminal strip cabling.

Regulation Options
Johnson Controls provides four different alternatives for the regulation of the airflow of the EC fans depending on the requirements of the installation: 1. Constant fan rotation speed. The available high static pressure is ideal for most applications. The effective air flow depends on the real pressure drop of the aeraulic system of the installation, however it can be calculated through Johnson Controls computerised selection program. 2. Constant airflow independent of the pressure drop of the filters. In order to maintain a constant airflow, an internal sensor guides the microprocessor management system to vary the airflow handled by the fan, depending on the degree of clogging of the filters. This ensures that insufficient cooling does not occur due to reduced airflow arising from dirty filters. 3. Variable airflow depending on the cooling capacity required by the installation. This is the classic VAV (Variable Air Volume) plant arrangement which responds to increased demand by a proportionate increase in airflow and vice versa. This type of plant offers interesting energy advantages at partial loads, which occur extensively throughout the year, especially at night. 4. Airflow as a function of pressure in the raised floor. This regulation alternative is envisaged for plants with raised floors where the air is distributed under the floor itself. The microprocessor management system maintains constant under-floor pressure. In particular, in very large areas subdivided into multiple local zones with partition dampers driven by individual thermostats, constant regulation of the pressure is necessary to avoid imbalances in the distribution of the air.

Electronically commutated fans (EC) for a perfect air flow regulation


Plug fans, made up by one or more backward curved, free running impeller, radial fans, offer several advantages: - particularly silent operation; - extremely high performance; - easy cleaning of the blades. Plug fans factory fitted with EC (electronically commutated) constant current brushless motors with external rotors are the latest innovation in energy saving when it comes to the fan sector. They are about 2530% more efficient than traditional asynchronous alternating current motors. They also allow continuous speed variation depending on the external sensor signal on the microprocessor control of the machine, without the need for an inverter or other electronic devices. At equal operating conditions, the combination of EC motors and plug fans therefore offers several advantages: - better functionality; - improved energy efficiency; - lower sound level; - absence of vibration in operation and soft start (lower absorbed current on starting).

Air Handling Systems & Terminal Devices

york air-conditioning products

Special versions
Water to air free cooling: using renewable energy sources
YC-OPW/FC, YC-UPW/FC air conditioners are equipped with a Free cooling system consisting of an additional chilledwater cooling coil integrated in the aluminium fins of the units direct expansion one, with a three-way modulating valve controlled by the modulating controller. As long as the outside conditions allow the water to respond totally or partially to the cooling request, the controller cuts out or minimises the compressors intervention, so reducing substantially the energy consumption. The water cooled condensers of the frigorific circuit are equipped with a pressostatic system for the regulation of the condensing pressure (flooding valves). The pumps and the expansion tank are not included in Johnson Controls supply. Units in free cooling version cannot install the optional hot water heating coil, only the electric one, and have as standard the analogue modulating controller. The system widely uses the outdoor aira renewable energy sourcein lieu of or in addition to the mechanical cooling.

Two Sources option utilising excess energy from building HVAC systems
This system consists of the same chilled-water cooling coil as the Free cooling, but fed by the building water chiller. A built in frigorific circuit enters in operation in case of lack of chilled water. The result is the maximum security or a remarkable reduction of both consumption and running costs. This system can also use the direct-expansion coil circuit as primary cooling source and, in case of an emergency, the chilled-water coil connected with the tap water network. The Two Sources version is available for units with direct expansion circuit YC-OPA./TS, YC-UPA./TS as well as units with built in water cooled condenser (accessory) and with double chilled water coil YC-OPU/TS, YC-UPU/TS: one for district water and the other for tap water or water from a chiller (emergency). Units in Two Sources cannot install the optional hot water heating coil, only the electric one, and have as standard the analogue modulating controller.

50 kW upflow 2 circuits direct expansion air conditioner

102/103

Fittings and accessories


Numerous accessories and options are available for the P Series air conditioners to personalise the installation depending on the requirements of the plant and its design. Divided by function, they include:

Free cooling or two sources


Additional Free cooling circuit. Additional Two sources circuit.

Direct expansion unit cooling capacity regulation


Electronic expansion valve. Electronic hot-gas injection system for the regulation of cooling capacity (100-10%).

Alarms
Water alarm (supplied loose). Out-of-range air discharge temperature alarm. Smoke/fire alarm terminals.

Heating, reheating and humidification


Single-step or double-step low thermal inertia electrical heating/ reheating coil. Immersed-electrode modulating humidifier and dehumidification control. Humidity sensor for the single control of dehumidification.

Water cooled condensers and pressostatic valves


Welded stainless steel water cooled plate condenser. 2 way pressostatic valve (only if the water condenser is selected).

Boards and sensors


Humidity sensor and board for external humidification control not supplied by Johnson Controls. RS 485 communication board.

Sound proofing devices


Sound damped duct for air suction or discharge (h=550 mm). Allows a reduction of approx 4 dB(A) of the SPL of the unit. Double layer sound damping panels. Reduces SPL by approx 2 dB(A) in upflow units (OP series), and approx.4 dB(A) in downflow units ((UP series). Double-layer sandwich thermo-acoustic insulation panels.

Dampers
Gravity-operated overpressure dampers on the air outlet (OP series). Motorised overpressure dampers on the air intake (UP series).

Panels and base


Blind front panel (OP) and open base for bottom air intake. Front panel with grille in the lower part (UP) and closed base.

Under bases
Adjustable under base (OP only). (Precise height to be specified with order). Adjustable under base with air deflector (UP only). (Precise height to be specified with order).

Plenum
Plenum (h=550 mm) for air discharge or intake with front grille. Plenum (h=550 mm) for air discharge or intake with front and side grilles.

Fans and filters


Electronic EC fans with incorporated inverter for constant rotation speed regulation. Electronic EC fans with incorporated inverter for the regulation of air flow in relation to the required cooling capacity. Electronic EC fans with incorporated inverter for the regulation of constant pressure in the raised floor. Electronic two-speed AC fans. F7 filter to be installed on the air intake as substitute for the standard G4. Monophase condenser-fan rotation speed variator

Air Handling Systems & Terminal Devices

york air-conditioning products

Performance at JOHNSON CONTROLS test conditions*


Technical Characteristics
YC-OPA: direct expansion air conditioners with air cooled or water condensers and up-flow air supply
Models Performances Total cooling capacity Sensible cooling capacity Airflow EER Sound pressure level Dimensions & weight Lenght Depth Height Net weight mm mm mm kg 750 630 1990 170 750 630 1990 170 750 630 1990 170 860 880 1990 210 860 880 1990 270 750 880 1965 270 1410 880 1990 300 1410 880 1990 315 1750 880 1990 330 1750 880 1990 400 1750 880 1990 420 1750 880 1990 440 2300 880 990 420 2300 880 990 490 2300 880 990 315 2640 880 1990 330 dB(A) kW kW m3/h 7.2 6.7 2200 3.09 49 11.2 10.6 3200 3.11 49 14.3 11.8 3200 3.15 49 20.9 19.8 7000 3.12 56 25.2 21.7 7000 3.05 56 30.4 29.4 8700 3.10 58 30.6 27.7 8700 3.18 58 38.2 31.0 8700 2.96 58 33.8 31.5 2.55 63 47.2 46.2 3.38 63 42.2 41.5 3.12 63 51.2 45.0 3.06 63 64.3 58.2 3.21 68 67.5 59.8 3.11 68 84.3 67.3 3.14 68 96.0 83.5 3.41 69 71 111 141 211 251 301 302 372 361 461 422 512 612 662 852 932

14500 14500 14500 14500 17900 17900 17900 22500

* The performances are referred to: refrigerant R410; condensing temperature: 45C; inlet air: 24C - 45% RH; for chilled water: 7/12C; The SPL is referred to 2 m distance, 1,5 m height, free field and sound damped discharge mouth. Available static pressure: 30 Pa. EER = Electro Efficiency Ratio = Total cooling capacity / Compressors + fans + condensers fans power input. The above performances dont consider the heat generated by the fans which must be added to the thermal load of the system.

Technical Characteristics
YC-UPA: direct expansion air conditioners with air cooled or water condensers and down-flow air supply
Models Performances Total cooling capacity Sensible cooling capacity Airflow EER Sound pressure level Dimensions & weight Lenght Depth Height Net weight mm mm mm kg 750 630 1990 170 750 630 1990 170 750 630 1990 170 860 880 1990 210 860 880 1990 255 750 880 1965 270 1410 880 1990 300 1410 880 1990 315 1750 880 1990 330 1750 880 1990 400 1750 880 1990 420 1750 880 1990 440 2300 880 990 420 2300 880 990 470 2300 880 990 315 2640 880 1990 330 dB(A) kW kW m3/h 7.2 6.7 2200 3.09 49 11.2 10.6 3200 3.11 49 14.3 11.8 3200 3.15 49 20.9 19.8 7000 3.12 56 25.2 21.7 7000 3.05 56 30.4 29.4 8700 3.10 58 30.6 27.7 8700 3.18 58 38.2 31.0 8700 2.96 58 33.8 31.5 2.55 63 47.2 46.2 3.38 63 42.2 41.5 3.12 63 51.2 45.0 3.06 63 64.3 58.2 3.21 68 67.5 59.8 3.11 68 84.3 67.3 3.14 68 96.0 83.5 3.41 69 71 111 141 211 251 301 302 372 361 461 422 512 612 662 852 932

14500 14500 14500 14500 17900 17900 17900 22500

* The performances are referred to: refrigerant R410; condensing temperature: 45C; inlet air: 24C - 45% RH; for chilled water: 7/12C; The SPL is referred to 2 m distance, 1,5 m height, free field and sound damped discharge mouth. Available static pressure: 30 Pa. EER = Electro Efficiency Ratio = Total cooling capacity / Compressors + fans + condensers fans power input. The above performances dont consider the heat generated by the fans which must be added to the thermal load of the system.

104/105

Performance at JOHNSON CONTROLS test conditions*


Technical Characteristics
YC-OPU: with chilled water coil and up-flow air supply
Models Performances Total cooling capacity Sensible cooling capacity Airflow Sound pressure level Dimensions & weight Lenght Depth Height Net weight mm mm mm kg 750 630 1990 155 750 630 1990 155 860 880 1990 180 860 880 1990 250 1750 880 1990 450 1750 880 1990 450 2640 880 1990 650 3496 880 1990 900 kW kW m3/h dB(A) 10.6 9.9 2200 47 19.6 17.2 3400 49 31.4 31.4 7800 57 41.3 38.8 8300 56 71.2 68.0 16000 59 92.5 83.2 17000 61 148.4 131.2 26400 64 178.8 148.7 34800 82 10 20 30 50 80 110 160 220

* The performances are referred to: refrigerant R410; condensing temperature: 45C; inlet air: 24C - 45% RH; for chilled water: 7/12C; The SPL is referred to 2 m distance, 1,5 m height, free field and sound damped discharge mouth. Available static pressure: 30 Pa. EER = Electro Efficiency Ratio = Total cooling capacity / Compressors + fans + condensers fans power input. The above performances dont consider the heat generated by the fans which must be added to the thermal load of the system.

Technical Characteristics
YC-UPU: with chilled water coil and down-flow air supply
Models Performances Total cooling capacity Sensible cooling capacity Airflow Sound pressure level Dimensions & weight Lenght Depth Height Net weight mm mm mm kg 750 630 1990 155 750 630 1990 155 860 880 1990 180 860 880 1990 250 1750 880 1990 450 1750 880 1990 450 2640 880 1990 650 3495 880 1990 900 kW kW m3/h dB(A) 11.1 8.4 2400 47 19.3 13.8 3500 49 30.6 24.5 7800 57 39 30 8300 56 69.2 53 16000 59 88 64.9 17000 61 151 106.5 26400 64 175.8 129.5 34000 82 10 20 30 50 80 110 160 220

* The performances are referred to: refrigerant R410; condensing temperature: 45C; inlet air: 24C - 45% RH; for chilled water: 7/12C; The SPL is referred to 2 m distance, 1,5 m height, free field and sound damped discharge mouth. Available static pressure: 30 Pa. EER = Electro Efficiency Ratio = Total cooling capacity / Compressors + fans + condensers fans power input. The above performances dont consider the heat generated by the fans which must be added to the thermal load of the system.

Air Handling Systems & Terminal Devices

york air-conditioning products

SmartPac
SmartPac from Johnson Controls offers factory packaged control solutions that reduce cost, enhance quality and optimise site time. Once on site, the equipment can be started immediately. Commissioning time is dramatically reduced, allowing to better control the project costs through simplifying equipment installation and commissioning. Quality is ensured through application and testing to European Installation regulations at the factory. Pre-installed software is configured to deliver air at the specified volume, temperature and humidity.
100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%

Wiring & Installation Control Panel

Commissioning Engineering
Site Fitted Manufacturer Factory Fitted SmartPac

Controls

106/107

SmartPac and YORK Air Handling units


The Air Handling Unit arrives on site ready to connect to the site network, and final commission is simplified through the units keypad and display. Panel Power wiring, controls wiring, Variable Speed Drive, preengineered controller and required peripheral devices are all supplied, factory fitted and tested.

SmartPac and YORK Fan Coil units


YORK Fan Coil Units are available with factory packaged controls and numerous options for controllers and valves to allow reduced installation time on site. Either EUBAC approved or alternative configurable controllers are offered, and a choice of BACNet, N2 Open or LON communication options is no extra cost. Valve requirements can also be met with a wide range of modulating and on/off actuators and isolation valves available and factory fitted.

SmartPac and YORK Roof Top & Close Control units


Factory packaged controls solution enable, to dramatically reduce on-site commissioning costs. Both are delivered to site with pre-installed controls, factory tested and ready to apply the power.

SmartPac and YORK Standard Control panel


With a standardized design the YORK Airside Equipment is a cost effective solution. Furthermore, Variable Speed Drives give extra efficiency communicating the Johnson controller in either full native BACNet or LON or N2 protocols allowing seamless communication with existing control systems.

Manufacturer reserves the rights to change specifications without prior notice.

Air Handling Systems & Terminal Devices

york air-conditioning products

108/109

Packaged Equipment & Large Split Systems


roomtop rooftop large split

york air-conditioning products

Control System
YKN2open
The YKlon is a controller regulating all components and accessories. It will pro actively manage cool and heat stages to maintain a stable room temperature maximizing the efficiency. Additionally, the benefits are: Redundancy on cool and heat stages (if one step is locked out, the PCB starts another one automatically). Random start between units to minimise electrical tariff. All stages will start in sequence to reduce peak inrush. Reduces nuisance calls by using 3 times you are out on all safeties before a hard lockout occurs. Automatic restart after power failure. Compressors run time priority. Alarm output relay and led diagnostic code. No parameters to check before starting. Lockout and incident level of protection. Last 10 lockouts stored in a non-volatile memory. 4 heating stages on hot water heating. BMS connection (N2 Open protocol).

YKtool N2open
The Yktool is the perfect tool to use on a regular basis for comissioning and service on site. For comissioning, it will override the thermostat and start the cooling or heating stages. Being a plug and play device, you will have direct acess to all sensors and status of each components and accessories installed (lockout & incidents, temperatures, defrost test...). Code: S613786031

110/111

Thermostat DPC-1
Day (normal), night (economy) and unoccupied (stand by). Lockout code on screen gives direct diagnostics. ON/OFF or programmable from dip switch setting. Day or night programmable state avoids wide internal temperature variation. 3 preset and 3 programmable profiles. Temperature override. Select the control sensor you want to use (integrated in the thermostat, return air in duct or room sensor). Turbo, normal or economy logic from dip switch setting. From 3C to +3C sensor offset. Average temperature with room or duct sensors.

Thermostats with integrated sensors


Thermostat models DPC-1 DPC-1R

Roomtop Rooftop Split system


Main features

Code RTC and RTH All models VAC and VAH VCH

S603786044 X X (1) X X

S603786045 0 0 0 0

Strategy Auto restart after power failure Number of cool stages Number of heat stages Auxiliary Heat Automatic Heat/Cool change over Continuous or auto indoor fan Manual setback (Day/Night key) Override possibility Compressor anti short cycle C Range cooling / heating Programmable, 7-day Lockout codes Outdoor air temperature Sensor selection X : Delivered as standard with the unit. O : Optional. l : Function available.

Turbo, normal or economy


l l

2 2
l l l

1 1
l l l

2 2

Day, night and unocuppied


l l l l

10 to 32C / 9 to 32C
l l l l l l

with YKlon
l

X (1) : Standard but has to be ordered separately.

Room sensor
RS-1

Indoor remote probe to provide close control of the ambient temperature at a location away from the DPC-1 and DPC-1R thermostats. Code: S603786042

Ambiance sensor
Digital remote probe to provide close control of the ambient temperature at a location away from DPC-1 and DPC-1R thermostats. Up to 4 remote probes can be connected to make an average of the room conditioned.
AS-1

Code: S603786049

Duct sensor
Remote probe to provide close control of the return air temperature in the duct, at a location away from DPC-1 and DPC-1R thermostats. The use of this probe is recommended when an indoor remote probe cannot be installed in the area where temperature is to be controlled.
DS-1

Code: S603786047

Packaged Equipment & Large Split Systems

york air-conditioning products

BMS Connection
IP Network

DPC-1

DPC-1

YKN2open

YKN2open

Light control, Power station...

AHU

VRF

CHILLER

112/113

BMS communication through new board YKN2Open delivered as standard (N2Open protocol) Possibility to fully control the unit and monitor more than 160 variables per unit. Can be integrated with other systems like lighting, fire&security or other HVAC equipment. Fully tailored solutions available (ask JCI sales office)

Sample screen

DPC-1

DPC-1

DPC-1

YKN2open

YKN2open

YKN2open

ACCESS CONTROL FIRE TVCC

Fire & Security

FAN COILS

HVAC application

Packaged Equipment & Large Split Systems

york air-conditioning products

Roomtop
RTC-RTH - L
A complete range from 14.6 kW up to 27.0 kW

YKN2open

Features
New YKN2open board Possibility to be installed outdoor Scroll Compressors High COP and EER 1/4 turn on electrical panel Expansion valves for models 20, 25 and 30 High external static pressure on evaporator and condenser Digital thermostat DPC-1 and indoor air filter included

RTC 15 L

Nomenclature
L = version Capacity range: 15 = 15 kW Product category: RTC = Cooling only RTH = Heat pump

Summer RTC-RTH
Evaporator

Winter RTH

Outdoor air

Condenser

4 ways valve Indoor air Outdoor air Indoor air

Compressor

Compressor

Standard air flow

Site modification

114/115

Roomtop
RTC-RTH 15 to 30 - L
Technical features
Cooling only models Cooling capacities Power input in cooling In duct outdoor side sound power level In duct indoor side sound power level Heat pump models Cooling capacities Power input in cooling Heating capacities Power input in heating In duct outdoor side sound power level In duct indoor side sound power level Common characteristics Power supply Nominal current RTC / RTH Starting current Main switch (1) Main cable (1) Cable to standard thermostat (2) Evaporator fan at nominal airflow Condenser fan at nominal airflow Nett dimensions Nett weight Nett weight Airflow Standard ESP Airflow Standard ESP Height Length Depth RTC RTH A A A Nbr.xmm2 Nbr.xmm2 m3/h Pa m3/h Pa mm mm mm kg kg 3 580 50 3 890 50 557 1 312 1 312 235 243 4 100 50 4 810 50 585 1 575 1 575 305 317 11.6 / 11.5 64 20 5x4 19 / 19 95 25 5x4 10 x 0.22 5 060 62 5 640 50 650 1 750 1 656 358 379 5 300 62 7 450 50 650 1 770 2 056 420 434 400V/3 + N/ 50Hz 21 / 21 111 25 5x4 23 / 23 118 32 5x6 kW kW kW kW dB(A) dB(A) kW kW dB(A) dB(A) RTC 15 L 14.60 5.50 72 71 RTH 15 L 14.10 5.40 13.80 4.84 74 73 RTC 20 L 19.90 8.60 74 73 RTH 20 L 19.90 8.32 17.80 7.15 74 73 RTC 25 L 22.20 10.00 77 75 RTH 25 L 22.20 10.04 20.80 7.89 81 81 RTC 30 L 27.00 12.00 81 75 RTH 30 L 26.80 11.63 25.40 9.67 81 81

(1) For information only. These should be checked for compliance with local regulations depending also on installation and cable type (2) Shield type cable only All the data are at EUROVENT conditions with 400V/3+N/50Hz. Cooling : Entering indoor coil temp. 27C / 19C WB and outdoor temperature 35C Heating : Entering indoor coil temp. 20C and outdoor temperature 7C / 6C WB

Compatibility table / Codes


Cooling only models Heat pump models Thermostat Delivered as standard with the unit Accessories or options Electrical Heaters * (in duct) Remarks 5 kW / 3ph. 10 kW / 3ph. 15 kW / 3ph. Code S611765653 S611765583 S611765513 S613111533 S613113087 * S606791243 Contact us O/A O RTC 15 L RTH 15 L A A A O O O/A O O O/A O O O/A O RTC 20 L RTH 20 L A A A DPC-1 RTC 25 L RTH 25 L A A A RTC 30 L RTH 30 L A A A RTC 15 L S661211545 RTH 15 L S662051544 RTC 20 L S661212081 RTH 20 L S662052054 RTC 25 L S661212545 RTH 25 L S662052545 RTC 30 L S661213045 RTH 30 L S662053045

Low ambient regulation Alarm relay board Copper-copper coils unit

A= Accessory (supplied loose). O= Option (factory fitted). O/A=If you want this item factory fitted, precise it in the order form. * Not protected against external conditions.

Manufacturer reserves the rights to change specifications without prior notice.

Packaged Equipment & Large Split Systems

york air-conditioning products

ACTIVA Rooftop
ARC-ARG-ARH-ARD
A complete range from 17 kW up to 40 kW

YKN2open

Features
High efficiency EER and COP Low noise level EC supply fan All configurations: Cooling only, Cooling + gas, Heating, Heating + Gas BMS connection as standard Compact design Energy recovery (enthalpy wheel) External HP & LP access Filters G4, F6 & F7 available

A R C 032 A B Nomenclature
B = Blue fin C = Copper fin (ask JCI) A = version Capacity range: 032 = 32 kW Product category: C = Cooling H = Heat pump G = Cooling & Gas D = Heat pump & Gas (Dual) Rooftop Activa series

116/117

ACTIVA Rooftop
ARC-ARG-ARH-ARD 017 to 040 AB
Technical features
Cooling only models Net cooling capacities Power input EER Working range (full load / partial load) Heat pump models Net cooling capacities Power input in cooling EER Heating capacities (1) Power input in heating COP Working range (full load / partial load) Cooling only + Gas heating models Net cooling capacities Cooling power input Standard Heating capacities (1) NET Natural gas 2ND-H, G20 Working range (full load / partial load) Heat pump + Gas heating models Net cooling capacities Power input in cooling Heating capacities (1) Power input in heating Standard Heating capacities (1) NET Natural gas 2ND-H, G20 Working range (full load / partial load) Common characteristics Power supply Main switch Main cable Cable to thermostat Number of circuits / Compressor type Airflow Evaporator fan at nominal airflow ASP Height Nett dimensions Length Depth Nett weight ARC / ARG Nett weight ARH / ARD kW kW C kW kW kW kW C kW kW kW m3/h C kW kW kW kW kW m3/h C ARG 017 AB 18.2 5.8 23 2.5 ARD 017 AB 18.2 5.8 18.1 5.7 23 2.5 ARH 017 AB 18.2 5.8 3.25 18.1 5.7 3.29 ARC 017 AB 18.2 5.8 3.25 ARC 022 AB ARC 032 AB 22.2 31 7.4 9.9 3.15 3.23 7C ~ 46C / -10C ~ 52C ARH 022 AB ARH 032 AB 22.2 31 7.4 9.9 3.15 3.23 22.1 30.9 6.9 9.8 3.36 3.23 -10C ~ 46C / -10C ~ 52C ARG 022 AB ARG 032 AB 22.2 31 7.4 9.9 23 41 2.5 4.5 -15C ~ 46C / -15C ~ 52C ARD 022 AB ARD 032 AB 22.2 31 7.4 9.9 22.1 30.9 6.9 9.8 23 41 2.5 4.5 -15C ~ 46C / -15C ~ 52C 400V/3 + N/ 50Hz A Nbr. x mm2 Nbr. x mm2 m3/h Pa mm mm mm kg kg 20 5x4 1 / 1 x Scroll 3400 600 1 420 1 866 1 540 420 / 462 425 / 467 4300 600 1 420 1 866 1 540 440 / 482 445 / 487 25 5x6 10 x 0,22 1 (Tandem) / 2 x Scroll 5700 7400 600 600 1 420 1 420 2 135 2 135 1 850 1 850 581 / 642 585 / 646 587 / 648 591 / 652 40 5 x 10 50 5 x 16 ARC 040 AB 39.9 14.2 2.9 ARH 040 AB 39.9 14.2 2.9 39.0 13.5 3.0 ARG 040 AB 39.9 14.2 41 4.5 ARD 040 AB 39.9 14.2 39.0 13.5 41 4.5

All the data are at EUROVENT conditions with 400V/3+N/50Hz. Cooling : Entering indoor coil temp. 27C / 19C WB and outdoor temperature 35C - Heating : Entering indoor coil temp. 20C and outdoor temperature 7C / 6C WB (1) Add indoor fan motor consumption to know total heating capacity.

Codes
Cooling only models Heat pump models Cooling only + Gas heating models Heat pump + Gas heating models
Thermostat

ARC 017 AB S661752110 ARH 017 AB S661752113 ARG 017 AB S661752111 ARD 017 AB S661752112

ARC 022 AB S661752120 ARH 022 AB S661752123 ARG 022 AB S661752121 ARD 022 AB S661752122 DPC-1

ARC 032 AB S661752130 ARH 032 AB S661752133 ARG 032 AB S661752131 ARD 032 AB S661752132

ARC 040 AB S661752150 ARH 040 AB S661752153 ARG 040 AB S661752151 ARD 040 AB S661752152

to be ordered separately

Manufacturer reserves the rights to change specifications without prior notice.

Packaged Equipment & Large Split Systems

york air-conditioning products

Activa rooftop details & features

High Efficiency
High efficiency compressor and fans managed by an smart control allows the unit to achieve and maintain the level of comfort required in the most efficient way, reducing therefore the energy bill.

Low Noise
Ultra quiet fans and optimized airflow reduces the noise level increasing the comfort. Compressors are mounted on shock absorbers and anti-vibration springs are available to avoid vibration transmissions into de building.

Easy Installation and Maintenance


The high level of usability of the control, the internal solutions adopted (like direct driven fans with variable speed) and the easy access to components simplify and reduce the need of external interventions. Full information on commissioning and maintenance plan are provided to help to ensure unit keeps running always in optimal conditions.

Compact Design
The refrigerant circuit layout has been redesigned and high efficiency exchangers been used to reduce the footprint and improve the transport and handling. Transition roofcurbs are available to fit in existing installations.

118/119

Accessories & options


Code Thermostat DPC-1 Dry bulb triple input economizer or motorized air damper with rain hood Enthalpy probes Indoor air quality sensor Power Exhaust Barometric relief damper and rain hood Fresh air damper and rain hood (2) Low ambient kit Roofcurb adapter (3) Fixed roof curb Adjustable roof curb Dirty filter switch Smoke detector Fire detection thermostat Hot water coil 16 kW 16 kW Electric heaters 25 kW 25 kW 37 kW Propane conversion Kit Filter kit F6 Filter kit F7 Grill condenser coil protection Antivibration mounting kit Return fan bottom duct * Energy recovery * Filter kit F6 for energy recovery ** Filter kit F7 for energy recovery ** Alarm relay board Copper-copper coil S603786044 S611752301 S611752311 S613990081 S606819964 S611752302 S611752312 S611752472 S611752473 S611752303 S611752313 S611752381 S611752886 S611752887 S611752881 S611752882 S611752883 S611752884 S613990085 S613995382 S613903003 S611752351 S611752352 S611752516 S611752616 S611752525 S611752625 S611752537 S611752780 S611752401 S611752402 S611752411 S611752412 S611752451 S611752452 S611752461 S611752361 S611752362 S611752501 S611752511 S611755506 S611755516 S611752507 S611752517 S606791243 Contact us O/A O O/A O O/A O/A O/A O/A O O/A O/A O O/A O O/A O O/A O/A O/A O/A O/A O/A O/A O/A O O/A O/A O O/A O O/A O A A A A O/A O/A O/A O/A O/A O/A O/A O/A O O/A O/A O O/A O O/A O A A A A A A A A A A O/A O/A O/A O/A O/A O/A O/A O/A O O/A O/A O O O O A O A A A A A A A A A A A O/A O/A O/A O/A O O O O O O O A O A A A A A A A A A A A O O O O O O O O O O O A O A A A A A A A O O O O O O O O O O O A O A O O O O O O O O O O O O O O O O A O A O O O O O O O A A A O A O O O A A O O O O O O O O O O O O O O A A A O O O A O O O O O O O O O O O O O A A A A A A A O O O A O O O O O O O O O O A O A A A A A A A A A A O O O A O O O O O O O O O A A A O A O O A O A A A A A A A A A A O O O A O O O O/A O/A O/A O/A A A A O A O O A O A A A A A A A O O/A O/A O O/A O/A O/A O/A O/A O/A O/A O/A A A A O A O O A O A A A Cooling only 017 A O 022 A O O O O/A O O O/A O O/A O/A O O/A O/A O/A O/A O/A O/A O/A O/A A A A O A O 032 A 040 A 017 A O Heat pump 022 A O O O O/A O O O/A O O/A O/A O O/A O/A O/A O/A O/A O/A O/A O/A 032 A 040 A Cooling + gas heating 017 A O 022 A O O O O/A O O O/A O O/A O/A O O/A O/A O/A O/A 032 A 040 A Heat pump + gas heating 017 A O 022 A O O O O/A O O O/A 032 A 040 A

O=Option (factory fitted). A=Accessory (supplied loose). O/A=If you want this item factory fitted, precise it in the order form. (1) Energy recovery accessory include: economizer, rain hood, indoor air quality sensor, enthalpy probe and G4 filters. (2) Fresh air damper can not be installed if economizer or motorized damper is fitted. (3) Transition roofcurbs to fit in D_IC/D_IG/B_IG existing installations (090-150 kbtu/h). * Ask JCI for availability ** available mid 2012

Packaged Equipment & Large Split Systems

Accessories & options

york air-conditioning products

ACTIVA Rooftop
ARC-ARG-ARH-ARD
A complete range from 45.1 kW up to 84 kW

YKN2open
Features
High efficiency EER and COP Low noise level All configurations: Cooling only, Cooling + gas, Heating, Heating + Gas New board with BMS connection (N2open protocole as standard) Energy recovery (enthalpy wheel) EC Return fan External HP & LP access Filters G4, F6 & F7 available Tandem configuration (up to 52C outdoor temperature)

A R C 045 A B Nomenclature
B = Blue fin C = Copper fin (ask JCI) A = version Capacity range: 045 = 45 kW Product category: C = Cooling H = Heat pump G = Cooling & Gas D = Heat pump & Gas (Dual) Rooftop Activa series

120/121

ACTIVA Rooftop
ARC-ARG-ARH-ARD 045 to 090 AB
Technical features
Cooling only models Net cooling capacities Power input EER Working range (full load / partial load) Heat pump models Net cooling capacities Power input in cooling EER Heating capacities (1) Power input in heating COP Working range (full load / partial load) Cooling only + Gas heating models Net cooling capacities Cooling power input Standard Heating capacities (1) Natural gas 2ND-H, G20 High Heating capacities (1) Natural gas 2ND-H, G20 Working range (full load / partial load) Heat pump + Gas heating models Net cooling capacities Cooling power input Heating capacities (1) Power input in heating Standard Heating capacities (1) Natural gas 2ND-H, G20 High Heating capacities (1) Natural gas 2ND-H, G20 Working range (full load / partial load) Common characteristics Power supply Main switch Main cable Cable to thermostat Number of circuits / Compressor type Airflow Evaporator fan at nominal airflow Power input Height Nett dimensions Length Depth Nett weight ARC / ARG Nett weight ARH / ARD kW kW C kW kW kW kW C kW kW kW m3/h kW m3/h C kW kW kW kW kW m3/h kW m3/h C ARG 045 AB 45.1 16.0 76.0 8.60 90.0 9.80 ARD 045 AB 47.6 17.0 45.2 16.0 76.0 8.60 90.0 9.80 ARH 045 AB 47.6 17.0 3.00 45.2 16.0 2.80 ARC 045 AB 45.1 16.0 2.96 ARC 060 AB ARC 075 AB 61.0 71.5 23.0 30.0 2.91 2.67 7C ~ 46C / -10C ~ 52C ARH 060 AB ARH 075 AB 61.9 71.4 20.0 28.0 3.06 2.67 58.0 71.7 19.0 27.0 2.96 2.81 -10C ~ 46C / -10C ~ 52C ARG 060 AB ARG 075 AB 61.0 71.5 23.0 30.0 76.0 76.0 8.60 8.60 90.0 90.0 9.80 9.80 -15C ~ 46C / -15C ~ 52C ARD 060 AB ARD 075 AB 61.9 71.4 20.0 28.0 58.0 71.7 19.0 27.0 76.0 76.0 8.60 8.60 90.0 90.0 9.80 9.80 -15C ~ 46C / -15C ~ 52C 400V/3 + N/ 50Hz A Nbr. x mm2 Nbr. x mm2 m3/h kW mm mm mm kg kg 50 5 x 10 63 5 x 16 10 x 0,22 2 x scroll 8 500 3 1 316 3 180 2 337 900 / 1 010 930 / 1 040 11 500 4 1 316 3 180 2 337 945 / 1 055 985 / 1 095 13 500 5,5 1 367 3 495 2 337 1 118 / 1 228 1 145 / 1 255 16 000 7,5 1 367 3 495 2 337 1 142 / 1 252 1 220 / 1 330 80 5 x 25 80 5 x 25 ARC 090 AB 84.0 36.0 2.60 ARH 090 AB 83.4 36.0 2.60 86.5 33.0 2.60 ARG 090 AB 84.0 36.0 76.0 8.60 90.0 9.80 ARD 090 AB 83.4 36.0 86.5 33.0 76.0 8.60 90.0 9.80

All the data are at EUROVENT conditions with 400V/3+N/50Hz. Cooling : Entering indoor coil temp. 27C / 19C WB and outdoor temperature 35C - Heating : Entering indoor coil temp. 20C and outdoor temperature 7C / 6C WB (1) Add indoor fan motor consumption to know total heating capacity.

Codes
Cooling only models Heat pump models Cooling only + Gas heating models Heat pump + Gas heating models
Thermostat

ARC 045 AB S661752140 ARH 045 AB S661752143 ARG 045 AB S661752141 ARD 045 AB S661752142

ARC 060 AB S661752160 ARH 060 AB S661752163 ARG 060 AB S661752161 ARD 060 AB S661752162 DPC-1

ARC 075 AB S661752170 ARH 075 AB S661752173 ARG 075 AB S661752171 ARD 075 AB S661752172

ARC 090 AB S661752190 ARH 090 AB S661752193 ARG 090 AB S661752191 ARD 090 AB S661752192

to be ordered separately

Manufacturer reserves the rights to change specifications without prior notice.

Packaged Equipment & Large Split Systems

york air-conditioning products

Activa rooftop details & features


PCB board

Condenser fan
New condenser fans with high technology blades and outdoor bell that reduce the turbulences in the air and therefore increase the efficiency and improve the noise level performance.

Tandem scroll compressors


Tandem compressors configuration allows the unit to operate at partial load (only with one compressor) with higher efficiency and increases the working range up to +52C ambient temperature.

PCB board
The new control board keeps same features and benefits as YKlon V3 (see pg. 159) and adds new logical to control the tandem circuit, the new options (heat recovery, return fan) and the possibility to communicate with BMS system as standard (N2Open).

Return fan
Located in a special roof curb underneath the rooftop, it works simultaneously with the indoor fan in order to balance the amount of air supplied to and removed from the space. It is the best suited for systems with high return path static pressures. Also, incorporates EC technology and a differential pressure gauge to easy set up and maintain automatically the working point in the installation.

122/123

Energy recovery system


It is the preferred solution to solve two conflicting requirements: reduce running costs (increase efficiency) while maintaining the indoor air quality at high levels (through ventilation). An enthalpy rotary wheel retains the energy from the exhaust air and transmits it to the fresh air stream that is being supplied in the conditioned space. The material used is manufactured with the latest technology to increase the energy transmission in both sensible and latent heat. The wheel is split into 6 portions that can be easily removed for cleaning.

V-Coils
Made in blue fin (or in copper for harsh conditions under special request), increases the heat exchange surface for a given rooftop footprint. The floor pan is sloped for easy condensates drainage.

Filter options
Washable air filters: G4 class filter (gravimetric efficiency above 90%) and M1 fire class, it comes with galvanized sheet metal frame that allows easy cleaning and replacement. Delivered as standard. Filter kit F6: for Average Opacimetric efficiency (em) 60% em 80% Filter kit F7: for Average Opacimetric efficiency (em) 80% em 90% As per EN 779

Packaged Equipment & Large Split Systems

york air-conditioning products

Accessories & options


Accessories & options
Code Thermostat DPC-1 Dry bulb triple input economizer or motorized air damper with rain hood Enthalpy probes Indoor air quality sensor Power Exhaust Barometric relief damper and rain hood Fresh air damper and rain hood (2) 4 kW 5.5 kW 7.5 kW 9.2 kW 11 kW 5.5 kW 11.5 kW S603786044 S661752301 S661752311 S613990081 S606819964 S661752302 S661752322 S613990472 S613990473 S661752303 S661752323 S611990401 S611990601 S611990701 S611990901 S611990902 S606744690 S606744691 S613118301 S613991482 S613991483 S613991884 S613991885 S613992081 S613992082 S613990085 S613995382 S613903003 S611083351 S611761584 S611762284 S611763385 S611764485 S611801780 S611803080 S611300401 S611300701 S611300901 S611300402 S611300702 S611300902 S661752304 S661752324 S661752314 S613990411 S613993042 S613993072 S611994501 S611994502 S611997501 S611997502 S611994506 S611997506 S611994507 S611997507 S606791243 Contact us Cooling only 45 A O O A A A A O O O O O O O O A A A A O O O O O O O O A O O A O O O O O O O O A O O A O O O O O O O O A O O O O O O O O O A A A A A A A A A A O/A O/A O/A O O/A O/A O/A O/A O O/A O/A O O/A O/A O O/A O/A O/A O O/A O/A O O/A O/A O O/A O/A O A A O/A O/A O/A O/A O A A O A A A A A A A A A A A A O O A A O A A O A A O O O O A O O O O O O O O A O A A O O O O O O O O A O O A O O O O O O O O A O O A O O O O O O O O A O O O A O O O O O O O O A O A A A 60 A O O A A A A A A A O O O O O O O O A A A A A A 75 A O O A A 90 A O O A A A A A A 45 A O O A A Heat pump 60 A O O A A 75 A O O A A 90 A O O A A

High speed drive

Soft start indoor fan Low ambient kit Side duct flanges Fixed roof curb Adjustable roof curb Dirty filter switch Smoke detector Fire detection thermostat Hot water coil

O O O A A

O O O A A

O O O A

O O O A

O O O A

O O O A

Electric heaters

12 kW 25 kW 37 kW 50 kW

Propane conversion Kit High heat gas conversion kit Filter kit F6

Filter kit F7

Grill condenser coil protection Antivibration mounting kit Return fan bottom duct Q6000 (1) Q3000 (1) Q9000 (1) Q4500 (1)

Energy recovery

Filter kit F6 for energy recovery Filter kit F7 for energy recovery Alarm relay board Copper-copper coil

O=Option (factory fitted). A=Accessory (supplied loose). O/A=If you want this item factory fitted, precise it in the order form. (1) = Energy recovery accessory include: economizer, rain hood, indoor air quality sensor, enthalpy probe and G4 filters. (2) Fresh air damper can not be installed if economizer or motorized damper is fitted

124/125

Accessories & options


Code Thermostat DPC-1 Dry bulb triple input economizer or motorized air damper with rain hood Enthalpy probes Indoor air quality sensor Power Exhaust Barometric relief damper and rain hood Fresh air damper and rain hood (2) 4 kW 5.5 kW 7.5 kW 9.2 kW 11 kW 5.5 kW 11.5 kW S603786044 S661752301 S661752311 S613990081 S606819964 S661752302 S661752322 S613990472 S613990473 S661752303 S661752323 S611990401 S611990601 S611990701 S611990901 S611990902 S606744690 S606744691 S613118301 S613991482 S613991483 S613991884 S613991885 S613992081 S613992082 S613990085 S613995382 S613903003 S611083351 S611761584 S611762284 S611763385 S611764485 S611801780 S611803080 S611300401 S611300701 S611300901 S611300402 S611300702 S611300902 S661752304 S661752324 S661752314 S613990411 S613993042 S613993072 S611994501 S611994502 S611997501 S611997502 S611994506 S611997506 S611994507 S611997507 S606791243 Contact us Cooling + gas heating 45 A O O A A A A O O O O O O O O A A A A O O O A O O O A O O O A O O O A A O O O A O O O A O O O A O O O A A A 60 A O O A A A A A A A O O O O O O O O A A A A A A 75 A O O A A 90 A O O A A A A A A 45 A O O A A Heat pump + gas heating 60 A O O A A 75 A O O A A 90 A O O A A

High speed drive

Soft start indoor fan Low ambient kit Side duct flanges Fixed roof curb Adjustable roof curb Dirty filter switch Smoke detector Fire detection thermostat Hot water coil

O O O A A

O O O A A

O O O A

O O O A

O O O A

O O O A

Electric heaters

12 kW 25 kW 37 kW 50 kW

Propane conversion Kit High heat gas conversion kit Filter kit F6

A O O

A O O

A O O

A O

A O O

A O O

A O O

A O

O O O O O O O A A A A A A A A A A O/A O/A O/A O O/A O/A O/A O/A O O/A O/A O O/A O/A O O/A O/A O/A O O/A O/A O O/A O/A O A A O/A O/A O/A O A A O A A A A A A A A A A O O A A O A A O O O

Filter kit F7

Grill condenser coil protection Antivibration mounting kit Return fan bottom duct Q6000 (1) Q3000 (1) Q9000 (1) Q4500 (1)

O A A

Energy recovery

A A O/A O/A O/A O

Filter kit F6 for energy recovery Filter kit F7 for energy recovery Alarm relay board Copper-copper coil

O=Option (factory fitted). A=Accessory (supplied loose). O/A=If you want this item factory fitted, precise it in the order form. (1) = Energy recovery accessory include: economizer, rain hood, indoor air quality sensor, enthalpy probe and G4 filters. (2) Fresh air damper can not be installed if economizer or motorized damper is fitted

Packaged Equipment & Large Split Systems

york air-conditioning products

Large Rooftop
DIC-BIH-DIG
A complete range from 119.1 kW up to 155.6 kW

Features YKlon 33 board


Duct work configuration side or down flow Cooling, heat pump, gas and electric heating Compact unit Wide range of accessories Suitable for use in harsh climates

D 4 IC 360 G 50 Nomenclature
Voltage code: 50 = 400V / 3 + N / 50 Hz Heating installed: G = R407C Capacity range: 360 = 360.000 Btu/h 1.000 Btu/h = 293 W Product identification: IC = Cooling only IH = Heat pump IG = Heat gas Product generation: 4 = 4th generation Product category: D = Packaged air conditioner (air-cooled) B = Heat pump

Adjustable roof curb types

126/127

Large Rooftop
DIC-BIH-DIG 360 to 480 G
Technical features
Models Gross cooling capacities (1) Power input in cooling (2) Heating capacities Power input in heating Cooling capacities (3) Power input in cooling (3) Heating capacities (3) Power input in heating (3) Gas heating capacities (3) Natural gas 2ND-H, G20 Power supply Nominal / Starting current Main switch Main cable Cable to thermostat DPC-1 Number of circuits Thermostat Airflow Standard ESP ESP with HSD Evaporator fan Power input at nominal airflow Power input HSD Drive Height Nett dimensions Length Depth Nett weight kW kW kW kW kW kW kW kW kW m3/h A A Nbr x mm2 Nbr x mm2 D4IC 360 G 119.1 31.4 111.6 42.4 D4IC 480 G 155.6 37.2 144.6 52.2 B4IH 360 G 115.1 32.0 127.1 41.9 107.6 43.0 127.1 41.9 B4IH 480 G 151.0 44.5 163.3 56.7 140.0 59.5 163.3 56.7 D4IG 360 G* 119.1 31.4 111.6 42.4 117 + 9.2 12.8 D4IG 480 G* 155.6 37.2 144.6 52.2 117 + 11 12.8 109 / 250 160 5 x 70 3 25 000 250 11 15

89 / 167 125 5 x 50 3

109 / 250 160 5 x 70

m /h Pa Pa kW kW
3

21 000 250 9.2 11

mm mm mm kg

2 010

400V/3 + N/ 50Hz 83 / 169 109 / 250 89 / 167 125 160 125 5 x 50 5 x 70 5 x 50 10 x 0,22 shield cable only 3 3 3 3 DPC-1 25 000 21 000 25 000 21 000 250 250 250 250 400 (Side duct connections) - 450 (Down duct connections) 11 9.2 11 9.2 15 11 15 11 Pulley - Belt (6 turns adjustable) 1.815 4.580 2.200 2 295 2 060 2 350 2 125

2 410

(1) : without heat from evaporator fan motor (2) : without evaporator fan motor (3) : All the data are at EUROVENT conditions with 230V/1/50Hz or 400V/3+N/50Hz Cooling : Entering indoor coil temp. 27C / 19C WB and outdoor temperature 35C - Heating : Entering indoor coil temp. 20C and outdoor temperature 7C / 6C WB * You should indicate airflow connection (side or down) when placing order.

Compatibility table / Codes


Cooling only models Heat pump models Cooling and gas heating models
Thermostat

D4IC 360 G S661723680 B4IH 360 G S661923680 D4IG 360 G S661763681 DPC-1

D4IC 480 G S661724880 B4IH 480 G S661924880 D4IG 480 G S661764882

to be ordered separately

Accessories or options
Models Thermostat DPC-1 Dry bulb triple input economizer or motorized air damper with rain hood (1) Enthalpy probe * Indoor air quality sensor * Power exhaust * Barometric relief damper + rain hood Fresh air damper and rain hood (2) High pressure drive 360 High pressure drive 480 Low ambient control 360 and 480 Hot water coil with control Electric heater 37 kW (2 stages) Electric heater 50 kW (2 stages) Electric heater 60 kW (2 stages) Washable air filter set G4 (EU4) Dirty filter switch Smoke detector Fire detection thermostat Fixed roof curb ** A Adjustable roof curb ** B C S603780044 S613993601 S613990081 S606819964 S613994880 S613990471 S613990488 S611993680 S611994880 S613113680 S611083651 S611763384 S611764484 S611765581 S611303680 S613990084 S613995381 S613903002 S613991980 S613992084 S613992085 S613992086 D4IC 360 G A O O O/A O/A O/A O O O O O O O O O O O A A A A D4IC 480 G A O O O/A O/A O/A O O O O O O O O O O O A A A A B4IH 360 G A O O O/A O/A O/A O O O O O O O O O O O A A A A B4IH 480 G A O O O/A O/A O/A O O O O O O O O O O O A A A A D4IG 360 G A O O O/A O/A O/A O O O D4IG 480 G A O O O/A O/A O/A O O O

O O O O A A A A

O O O O A A A A

O=Option (factory fitted). A=Accessory (supplied loose). O/A=If you want this item factory fitted, precise it in the order form. * It is mandatory to order the economizer with this item. ** Delivered in kit form. (1) You should indicate airflow connection (side or down) when placing order. (2) Fresh air damper can not be installed if economizer or motorized damper is fitted

Manufacturer reserves the rights to change specifications without prior notice.

Packaged Equipment & Large Split Systems

york air-conditioning products

Rooftop & Large Rooftop accessories & options


Triple input economizer
This system utilizes 3 probes: Return Air, Outdoor Air and Supply Air. The Outdoor Air damper and the Return Air dampers are mechanically interconnected in order to provide the same airflow at the coil inlet, with a single damper motor. The PCB compares sensor values and modulates the dampers providing maximum efficiency of the economiser system (free cooling) and comfort (Supply Air > 12C). Combined with the air quality sensor, your payback will be ensured within few months. The rain hood is painted to match the basic unit and aluminium mesh prefilter prevents water penetration.

Indoor air quality


This sensor measures concentrations of pollutant gases, such as tobacco smoke, human body odours, kitchen odours, carbon monoxide, etc It automatically overrides the economizer when pollutant levels rise above preset limits. A shorting plug will set the algorithm to acceptable, good or very good air quality. This VOC sensor (Volatile Organic Compounds) sends an ON/OFF signal to the control PCB. The YKlon will then adjust the fresh air damper, optimising indoor air quality and minimising the energy consumption.

Motorised outdoor air damper


Equipped with the same dampers as the economizer, the Return Air probe is not used. Outdoor air damper opens to pre-set position whenever the indoor fan is operating (selected from the thermostat, the indoor fan can be activated with the compressor or to operate continuously) and will drive fully closed when the indoor fan shuts down. The rain hood is painted to match the basic unit and aluminium mesh pre-filter prevents water penetration.

Power Exhaust
Used to mechanically relieve internal air pressure from the Return Air section and ensure efficient fresh air introduction on units equipped with triple input economiser or motorised air damper. The power exhaust fan motor works when enough Outdoor Air is blowing into the room and if Outdoor Air temperature is acceptable (12C < t < 30C).

Enthalpy sensors
To control the economizer in humid areas, or when indoor air humidity needs to remains dry, you should select enthalpy regulation. Enthalpy sensors will be used with the triple input economizer.

High speed drive


The high speed drive will increase the supply fan performance for applications requiring greater air flow and/ or static pressure. Please consult technical guide for more information.

Barometric relief damper


This accessory can be used to relieve internal air pressure on units equipped with triple input economiser or motorised air damper but no power exhaust. When the rooftop is working in free cooling or introducing fresh air, the damper opens to relieve over pressure from the return air section. This accessory is comprised of a rain hood, a protective grille and a fully assembled damper.

Dirty filter switch


Ensures that clean air is being supplied, advises when maintenance is required to prevent excessive depression and ensures water integrity of the AHU. These are the main advantages of filter dirty switch. Connected with the DPC-1 thermostat, the filter icon will appear on the thermostat screen when a filter change is required.

Fresh air damper and rain hood


The most cost effective method with a complete rain hood and a fixed damper that can be adjusted to provide approximately 10, 15 or 25% of fresh air.

Low ambient control


All our rooftops are designed to work in cooling mode down to 7C ambient temperatures. Although this working range suits most applications, the units can operate correctly down to -18C with optional low ambient control.

Fire detection thermostat


This fire detection thermostat is protecting the AHU but must not be used to ensure a full building protection against fire danger. The standard AHU is protected as standard with a Supply Air probe that shuts the unit down (lockout) when temperature exceeds 80C. The electro-mechanical fire detection thermostat is used to fulfil specific local requirement. A manual reset is necessary.

Smoke detector
The smoke detector is protecting the AHU but must not be used to ensure a full building protection against smoke danger. If smoke is detected the AHU is shutdown (lockout). A manual reset is necessary.

128/129

Fixed and adjustable roof curbs


Ideal for down-flow applications, it is a great help for installation allowing duct connections, electrical connection and weatherproofing between the roofcurb and the roof of the building. Shipped in kit form, it also gives sufficient height for condensate trap operation. The adjustable roof curbs have the same benefits as the fixed roof curb, it allows the rooftop to be levelled on a roof with up to 7 slope (4%).

Hot water coil with control


The hot water coil and his control are always fitted, wired and factory tested. Located in the supply air section, side or bottom duct connection is possible without any modification. Complete with an anti-frost thermostat, the PCB will activate the modulated valve (24V supply, 0 10V modulating signal) in order to get the best comfort. A jumper will allow using hot water coil as 1st heating stage.

Side duct flanges


Fitted as standard on units 90, 120 and 150, this accessory is composed of easy to install sheet metal panels to allow ductwork connections on the side of the AHU for horizontal return air and/or supply air.

Electric heaters
Available on cooling only and Heat pump units, the electric heater is protected with two overheats per element. When the overheat operates, there is a lock out of the faulty electric heater stage and the PCB starts automatically another heat stage.

Kit conversion propane


This kit comprises replacement burner, pilot injectors and all necessary instructions for converting the natural gas burner to propane gas. The nominal pressure of the propane gas should be 37 mbar.

High heat gas


This kit comprises replacement burner injectors and all necessary instructions to provide high heat capacity for gas rooftop.

Energy recovery
Attached to the return air box of the rooftop, a rotary enthalpy wheel retrieves the energy of the exhausted air and transmits it to the fresh air intake. A special material used in the wheel allows that latent heat as well as sensible heat are transmitted.

Antivibration mounting kit


It is composed by a set of stainless steel springs, to be assembled underneath the rooftop in a specific position. Their installation avoids the potential vibration transmission of the equipment to the building and reduces therefore the noise level (compressors have their own shock absorbers delivered as standard).

Indoor fan soft start


Compact control unit with a motor with AC semiconductors, designed for soft starting and stopping of three-phase motors for centrifugal fans. The starting time, the stopping time and the initial torque are adjusted by mean of independent potentiometers.

Return fan
Used to overcome high return path pressure drops, works in series with the indoor fan to maintain the air pressure of the conditioned space within acceptable levels.

Grill condenser protection


Metallic frame painted with oven-baked polymerized paint (800h salt spray resistance) to protect the fins of the coils from external damages.

Air filters
G4, F6 and F7 filters are available to purify the air in the room. M1 fire class and manufactured in sheet metal frame, they are easy to install and clean.

Packaged Equipment & Large Split Systems

york air-conditioning products

VITALITY Axial Fan Large Split


VAC/VAH - VIR 20 to 90 AB
A complete range from 19.1 kW up to 86.1 kW

YKN2open
Features
New YKN2open board High technology fan blades increases efficiency and reduces noise level Service valves Economizer or motorized damper Return fan Indoor air quality Hot water coil and control Scroll compressor with crankcase heater Digital thermostat DPC-1 included

V A H 40 A B

Nomenclature
B = Blue fin C = Copper fin (ask JCI) A = version Capacity range: 40 = 40 kW Product category: C = Cooling only H = Heat Pump R = Reversible I = Indoor A = Axial V = Vitality

130/131

VITALITY Axial Fan Large Split


VAC/VAH - VIR 20 to 90 AB
Technical features
INDOOR UNITS Cooling only and Heat pump OUTDOOR UNITS Cooling only models Cooling capacities Power input in cooling EER (4) Refrigerant charge on site for 7 m piping length Heat pump models Cooling capacities Power input in cooling EER (4) Heating capacities Power input in heating COP (4) Refrigerant charge on site for 7 m piping length Power supply Nominal / Starting current Main switch (1) Main cable to the outdoor unit (1) Interconnecting cable (1) Cable to standard thermostat (2) VAC kW kW kg VAH kW kW kW kW kg 20AB 19.10 5.60 3.41 12 20AB 19.10 5.60 3.41 21.20 4.94 4.29 12 25AB 23.00 6.99 3.29 12 25AB 23.00 6.99 3.29 25.20 6.73 3.74 12 30AB 28.80 9.60 3.00 12.5 30AB 28.80 9.60 3.00 31.90 8.41 3.79 12.5 40AB 35.10 11.62 3.02 13.5 40AB 35.10 11.62 3.02 41.00 12.09 3.39 13.5 45AB 42.90 13.53 3.17 2 x 11 45AB 42.90 13.53 3.17 44.80 12.69 3.53 2 x 11 60AB 54.00 18.60 2.90 2 x 11.5 60AB 52.10 18.60 2.80 59.40 17.06 3.48 2 x 11.5 75AB 72.30 23.09 3.13 2 x 15.5 75AB 72.30 23.09 3.13 81.00 22.13 3.66 2 x 15.5 90AB 86.10 28.60 3.01 2 x 15 90AB 86.10 28.60 3.01 93.10 28.82 3.23 2 x 15 VIR 25AB 40AB 45AB 60AB 75AB 90AB

A A Nbr x mm2 Nbr x mm2 Nbr x mm2 Suction Insulated refrigerant piping Liquid m3/h Airflow Standard ESP Pa Evaporator fan VIR at nominal airflow (3) ESP with HSD Pa ESP with HSDM Pa mm Height Nett dimensions Length mm outdoor VAC / VAH Depth mm mm Height Nett dimensions Length mm indoor VIR Depth mm kg VAC / VAH Nett weight VIR kg

8.5 / 74 20 5x4 4 x 1.5 1-1/8 1/2 4 590 172 267 267 1 230 882 1 354 592 1360 785 227 128

11.8 / 95 25 5x4 4 x 1.5 1-1/8 1/2 4 590

15 / 118 32 5x6 4 x 1.5

1 230 882 1 354

228

400V/3 + N/ 50Hz 19.3 / 140 2 x 12 / 95 2 x 15 / 118 40 50 63 5 x 10 5 x 10 5 x 16 4 x 1.5 4 x 1.5 4 x 1.5 10 x 0.22 1-1/8 1-1/8 2 x 1-1/8 2 x 1-1/8 5/8 5/8 2 x 1/2 2 x 5/8 7 500 7 500 9 000 10 500 153 150 178 242 203 277 242 203 277 1 382 1 378 1 378 / 1 429 1 378 / 1 429 882 1 627 1 627 1 627 1 354 1 453 1 453 1 453 665 764 764 1740 2240 2240 785 772 772 250 397 560 562 173 250 250

2 x 19 / 140 80 5 x 25 4 x 1.5 2 x 1-3/8 2 x 7/8 13 000 170 289 289 1 534 1 627 2 099 838 2653 892 610 340

2 x 25 / 198 100 5 x 35 4 x 2.5 2 x 1-3/8 2 x 7/8 16 000 240 399 399 1 534 1 627 2 099 838 2653 892 610 342

(1) For information only. These should be checked for compliance with local regulations depending also on installation and conductor type. (2) Shield type cable only. (3) ESP = External static pressure HSD = High speed drive HSDM = High speed drive and motor (4) All the data are at EUROVENT conditions with 400V/3+N/50Hz. Cooling : Entering indoor coil temp. 27C / 19C WB and outdoor temperature 35C Heating : Entering indoor coil temp. 20C and outdoor temperature 7C / 6C WB

Codes
INDOOR UNITS Cooling only & heat pump models OUTDOOR UNITS Cooling only models Heat pump models Thermostat Delivered with the unit DPC-1 VAC 20 AB VAC 25 AB VAC 30 AB VAC 40 AB S661502073 S661502573 S661503073 S661504173 VAH 20 AB VAH 25 AB VAH 30 AB VAH 40 AB S662512073 S662512573 S662513073 S662514173 VAC 45 AB VAC 60 AB VAC 75 AB VAC 90 AB S661504673 S661506173 S661507673 S661509173 VAH 45 AB VAH 60 AB VAH 75 AB VAH 90 AB S662514673 S662516273 S662517673 S662519173 VIR 25 AB S662562575 VIR 40 AB S662564075 VIR 45 AB S662564575 VIR 60 AB S662566075 VIR 75 AB S662567575 VIR 90 AB S662569075

Manufacturer reserves the rights to change specifications without prior notice.

Packaged Equipment & Large Split Systems

york air-conditioning products

Accessories or options
Compatibility table / Codes
INDOOR UNITS Cooling only & heat pump OUTDOOR UNITS Cooling only models VAC 20 AB VAC 25 AB VAC 30 AB VAC 40 AB VAC 45 AB VAC 60 AB VAC 75 AB VAC 90 AB S661502073 S661502573 S661503073 S661504173 S661504673 S661506173 S661507673 S661509173 VAH 20 AB VAH 25 AB VAH 30 AB VAH 40 AB VAH 45 AB VAH 60 AB VAH 75 AB VAH 90 AB S662512073 S662512573 S662513073 S662514173 S662514673 S662516273 S662517673 S662519173 VIR 25 AB S662562575 VIR 40 AB S662564075 VIR 45 AB VIR 60 AB VIR 75 AB VIR 90 AB S662564575 S662566075 S662567575 S662569075

Heat pump models Thermostat Delivered with the unit Accessories or options for outdoor units S606819974 S606819975 S606744692 S606744693 S606791243 Contact us

DPC-1

Low Ambient Kit Soft start compressor Alarm relay board Copper-copper coil Accessories or options for indoor units VIR models 10 kW (1 stage) 15 kW (1 stage) 10 kW (1 stage) Electrical Heaters 20 kW (2 stages) (Inside the unit) (cable 20 m included) 15 kW (1 stage) 30 kW (2 stages) 30 kW (2 stages) 40 kW (2 stages) 1 stage 50 m connecting cable 2 stages Economizer or Motorised damper (dry bulb sensors included) (cable 20 m included) Indoor air quality Hot water coil and control (cable 20 m included) 50 m communication cable (Economizer/HWC) Return fan

20AB O O O/A O

25AB O O O/A O

30AB O O O/A O

40AB O O O/A O

45AB O O O/A O

60AB O O O/A O

75AB O O O/A O

90AB O O O/A O

25A S611763704 S611763714 S611763724 S611763734 S611763744 S611763754 S611763764 S611763774 S611763780 S611763781 S613994250 S613994400 S613994450 S613994750 S606819964 S611082513 S611084010 S611084512 S611087510 S611087520 * S613995450 S613995750 S669482502 S669484002 S669486002 S669487502 S606744690 S611991087 S611991089 S611991091 S611991092 S611991095 S611991088 S611991090 S611991093 S611991094 S611991096 O/A O/A

40AB

45AB

60AB

75AB

90AB

O/A O/A O/A O/A O/A O/A O/A O/A A A A A A O A O O A A A A O A A O A A O O O O O O O O O O O O O O O O O O O O O O O O A A A A A A A A A A A A A A A A O/A O/A A

Vertical discharge Kit Indoor fan smooth start up to 5,5 kW

High speed drive

High speed drive and motor

O = Option (factory fitted) A = Accessory (supplied loose) O/A = If you want this item factory fitted, precise it in the order form (1) Factory fitted, for horizontal airflow only. * If the unit is equipped with economizer and hot water coil, only 1 communication cable is necessary.

132/133

VIR 25 AB
M N K

Piping connections
All dimensions in mm. Drawings not a scale.
Unit VIR 25 AB A B C D E F G H I J K L M N

592

1360

785

480

403

480

347

40

1094

520

21

Electrical connections

25

VIR 40-45-60 AB
M N K

Electrical connections

Piping connections
All dimensions in mm. Drawings not a scale.
Unit VIR 40 AB VIR 45 AB VIR 60 AB A B C D E F G H I J K L M N

665 764 764

1740 2240 2240

785 772 772

442 567 567

316 401 401

229 309 309

316 401 401

442 567 567

347 347 347

79 79 79

1337 1920 1920

593 692 692

21 21 21

25 25 25

VIR 75-90 AB
M N K

Electrical connections

Piping connections
All dimensions in mm. Drawings not a scale.
Unit VIR 75 AB VIR 90 AB A B C D E F G H I J K L M N

838 838

2653 2653

892 892

663 663

478 478

376 376

478 478

663 663

409 409

79 79

2196 2196

766 766

21 21

25 25

Packaged Equipment & Large Split Systems

Indoor units dimensions


J

york air-conditioning products

Dimensions and space requirements for outdoor units


VAC-VAH 20-25-30 AB

All dimensions in mm. Drawings not a scale.

VAC-VAH 40-45-60 AB

All dimensions in mm. Drawings not a scale.

134/135

VAC-VAH 75-90 AB

All dimensions in mm. Drawings not a scale.

VAC-VAH 20-25-30 AB
A B C D

Unit
VAC 20 AB VAH 20 AB VAC 25 AB VAH 25 AB VAC 30 AB VAH 30 AB

Gas piping diameter 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8

Liquid piping diameter 1/2 1/2 1/2 1/2 5/8 5/8

mm 1 030 1 030 1 030 1 030 1 182 1 182

mm 1 230 1 230 1 230 1 230 1 382 1 382

VAC-VAH 40-25-60 AB
A B C D

Unit
VAC 40 AB VAH 40 AB VAC 45 AB VAH 45 AB VAC 60 AB VAH 60 AB

Gas piping diameter 1-1/8 1-1/8 2 x 1-1/8 2 x 1-1/8 2 x 1-1/8 2 x 1-1/8

Liquid piping diameter 5/8 5/8 2 x 1/2 2 x 1/2 2 x 5/8 2 x 5/8

mm 1 178 1 178 1 178 1 129 1 178 1 129

mm 1 378 1 378 1 378 1 429 1 378 1 429

VAC-VAH 40-25-60 AB
A B C D

Unit
VAC 75 AB VAH 75 AB VAC 90 AB VAH 90 AB

Gas piping diameter 2 x 1-3/8 2 x 1-3/8 2 x 1-3/8 2 x 1-3/8

Liquid piping diameter 2 x 7/8 2 x 7/8 2 x 7/8 2 x 7/8

mm -

mm -

Packaged Equipment & Large Split Systems

york air-conditioning products

VITALITY Centrifugal Large Split


VCH-VIR 20 to 90 AB
A complete range from 16.8 kW up to 87.3 kW

YKN2open

Features
New YKN2open board High efficiency EER and COP Economizer or motorized damper Indoor air quality Hot water coil and control Scroll compressor with crankcase heater Possibility to be installed outdoor Return fan Digital thermostat DPC-1 included

V C H 40 A B

Nomenclature*
B = Blue fin C = Copper fin (ask JCI) A = version Capacity range: 40 = 40 kW Product category: H = Heat Pump R = Reversible C = Centrifugal I = Indoor V = Vitality

VIR - Indoor unit details


Return fan Economizer

* Check codes in next page for discharge configuration

VIR unit

Piping

Air filter

Hot water coil

136/137

VITALITY Centrifugal Large Split


VCH-VIR 20 to 90 AB
Technical features
VITALITY UNITS Heat pump models Cooling capacities Power input in cooling EER Heating capacities Power input in heating COP Refrigerant charge on site for 7m piping length Power supply Nominal / Starting current Main switch (1) Main cable to the condensing unit (1) Interconnecting cable (1) Cable to standard thermostat (1) (2) Insulated refrigerant piping Airflow Evaporator fan VIR at nominal airflow (3) ESP with HSD Condenser fan at nominal airflow Airflow Standard ESP Height Standard ESP A A Nbr x mm2 Nbr x mm2 Nbr x mm2 Suction Liquid m3/h Pa Pa m3/h Pa mm mm mm mm mm mm kg kg 285 128 6235 50 1392 1362 790 592 1360 785 310 355 173 1 1/8" 1/2" 4 590 117 222 6235 50 1392 1362 790 11975 50 1526 1740 785 665 1740 785 375 1 1/8" 1/2" 1 1/8" 5/8" 7 500 118 217 11975 50 1526 1740 785 1 1/8" 5/8" 13 / 20 5x4 4 x 1.5 16 / 25 5x4 4 x 1.5 22 / 32 5x6 4 x 1.5 kg kW kW VCH/VIR kW kW 20 AB 16.8 5.9 2.85 21.5 5.68 3.79 8.5 25 AB 20.6 7.48 2.75 23.2 6.84 3.39 8.5 30 AB 28.7 10.25 2.8 32.3 9.95 3.25 12 40 AB 32.4 12.81 2.53 39.3 12.87 3.05 12 45 AB 43.5 14.81 2.94 47.4 13.75 3.45 2 x 9.5 60 AB 54.1 20.86 2.6 53 20 2.8 2 x 10.5 75 AB 76.1 29.21 2.61 77.7 27.56 2.82 2 x 15 90 AB 87.3 34.92 2.5 89.9 33.19 2.71 2 x 16

400V/3 + N/ 50Hz 27 / 40 5 x 10 4 x 1.5 10 x 0.22 2 x 1 1/8" 2 x 1/2" 9000 130 188 188 17250 50 1641 2240 778 764 2240 772 578 223 2 x 1 1/8" 2 x 5/8" 10500 137 246 246 20340 50 1641 2240 778 764 2240 772 589 223 2 x 1 3/8" 2 x 7/8" 13700 125 260 260 25200 50 1794 2658 897 838 2653 892 710 310 2 x 1 3/8" 2 x 7/8" 16000 175 354 25200 50 1794 2658 897 838 2653 892 715 312 33 / 50 5 x 10 4 x 1.5 43 / 63 5 x 16 4 x 1.5 59 / 80 5 x 25 4 x 1.5 72 / 100 5 x 35 4 x 2.5

ESP with HSDM Pa

Nett dimensions VCH Length condensing units Depth Nett dimensions VIR indoor units Nett weight Height Length Depth VCH VIR

(1) For information only. These should be checked for compliance with local regulations depending also on installation and conductor type. (2) Shield type cable will have a better insulation against electromagnetic interference. It is recommended for sensitive sites and for communications. (3) ESP = External static pressure HSD = High speed drive HSDM = High speed drive and motor All the data are at EUROVENT conditions with 400V/3+N/50Hz. Cooling : Entering indoor coil temp. 27C / 19C WB and outdoor temperature 35C Heating : Entering indoor coil temp. 20C and outdoor temperature 7C / 6C WB

Codes
INDOOR UNITS Cooling only & heat pump models OUTDOOR UNITS Heat pump models with horizontal discharge with vertical discharge Thermostat Delivered with the unit DPC-1 VCH 20 AB VCH 25 AB VCH 30 AB VCH 40 AB VCH 45 AB VCH 60 AB VCH 75 AB VCH 90 AB S662512043 S662512653 S662513043 S662514044 S662514543 S662516153 S662517543 S662519043 S662514565 S662516174 S662517564 S662519064 VIR 25 AB S662562575 VIR 40 AB S662564075 VIR 45 AB S662564575 VIR 60 AB S662566075 VIR 75 AB S662567575 VIR 90 AB S662569075

Manufacturer reserves the rights to change specifications without prior notice.

Packaged Equipment & Large Split Systems

york air-conditioning products

Accessories or options
Compatibility table / Codes
INDOOR UNITS Cooling only & heat pump models OUTDOOR UNITS Heat pump models with horizontal discharge with vertical discharge Thermostat Delivered with the unit Accessories or options for condensing units VCH models Low ambient regulation * S613112583 S613114084 S613116084 S613111084 S612828305 S612828405 S612828505 ** S612828605 ** S612828205 ** S611080789 S611080790 S606791243 Contact us 20 AB O 25 AB O 30 AB O 40 AB O O O O O O O O O A O/A O 25 AB O/A O/A A O/A O A O/A O 40 AB A O/A O A O/A O 45 AB A O/A O 60 AB A O/A O 75 AB A O/A O 90 AB O O O O 45 AB 60 AB 75 AB 90 AB VIR 25 AB S662562575 VIR 40 AB S662564075 VIR 45 AB VIR 60 AB VIR 75 AB VIR 90 AB S662564575 S662566075 S662567575 S662569075 VCH 20 AB VCH 25 AB VCH 30 AB VCH 40 AB VCH 45 AB VCH 60 AB VCH 75 AB VCH 90 AB S662512043 S662512653 S662513043 S662514044 S662514543 S662516153 S662517543 S662519043 S662514565 S662516174 S662517564 S662519064 DPC-1

Vertical discharge kit

Condensate tray heater Alarm relay board Copper-copper coil Accessories or options for indoor units VIR models 10 kW (1 stage) 15 kW (1 stage) 10 kW (1 stage) Electrical Heaters 20 kW (2 stages) (Inside the unit) (cable 20 m included) 15 kW (1 stage) 30 kW (2 stages) 30 kW (2 stages) 40 kW (2 stages) 1 stage 50 m connecting cable 2 stages Economizer or Motorised damper (dry bulb sensors included) (cable 20 m included) Indoor air quality Hot water coil and control (cable 20 m included) 50 m communication cable (Economizer/HWC) Return fan

Vertical discharge Kit Indoor fan smooth start up to 5,5 kW

High speed drive

High speed drive and motor

S611763704 S611763714 S611763724 S611763734 S611763744 S611763754 S611763764 S611763774 S611763780 S611763781 S613994250 S613994400 S613994450 S613994750 S606819964 S611082513 S611084010 S611084512 S611087510 S611087520 *** S613995450 S613995750 S669482502 S669484002 S669486002 S669487502 S606744690 S611991087 S611991089 S611991091 S611991092 S611991095 S611991088 S611991090 S611991093 S611991094 S611991096

O/A O/A O/A O/A O/A O/A O/A O/A A A A A A O A O O A A A A O A A O A A O O O O O O O O O O O O O O O O O O O O O O O O A A A A A A A A A A A A A A A A O/A O/A A

O = Option (factory fitted). A = Accessory (supplied loose). O/A = If you want this item factory fitted, precise it in the order form. * Not protected against external condition. ** To be used only with horizontal discharge models *** If the unit is equipped with economizer and hot water coil, only 1 communication cable is necessary.

138/139

VIR 25 AB
M N K

Piping connections
All dimensions in mm. Drawings not a scale.
Unit VIR 25 AB A B C D E F G H I J K L M N

592

1360

785

480

403

480

347

40

1094

520

21

Electrical connections

25

VIR 40-45-60 AB
M N K

Electrical connections

Piping connections
All dimensions in mm. Drawings not a scale.
Unit VIR 40 AB VIR 45 AB VIR 60 AB A B C D E F G H I J K L M N

665 764 764

1740 2240 2240

785 772 772

442 567 567

316 401 401

229 309 309

316 401 401

442 567 567

347 347 347

79 79 79

1337 1920 1920

593 692 692

21 21 21

25 25 25

VIR 75-90 AB
M N K

Electrical connections

Piping connections
All dimensions in mm. Drawings not a scale.
Unit VIR 75 AB VIR 90 AB A B C D E F G H I J K L M N

838 838

2653 2653

892 892

663 663

478 478

376 376

478 478

663 663

409 409

79 79

2196 2196

766 766

21 21

25 25

Packaged Equipment & Large Split Systems

Indoor units dimensions


J

york air-conditioning products

Dimensions and space requirements for condensing units


VCH 20-25 AB
600 D E 600 * 600 600

Electrical electrical connections


connections

Piping piping connections


K

Minimum clearance

* No clearance required if air ducted

All dimensions in mm. Drawings not a scale.


Unit VCH 20 AB VCH 25 AB A B C D E F G H I J K L

1 392 1 392

1 362 1 362

790 790

147 147

1 069 1 069

30 30

268 268

37 37

919 919

138 138

1 100 1 100

24 24

VCH 30-40 AB
600 D E 600 * 600 600

Electrical electrical connections


connections

Piping piping connections


K

Minimum clearance

* No clearance required if air ducted

All dimensions in mm. Drawings not a scale.


Unit VCH 30 AB VCH 40 AB A B C D E F G H I J K L

1 526 1 526

1 740 1 740

785 785

151 151

1436 1436

30 30

324 324

37 37

994 994

141 141

1476 1476

24 24

140/141

VCH 45-60 AB
600 D E F G 600 * 600 600

Electrical electrical connections connections Piping piping connections


C B

Minimum clearance
All dimensions in mm. Drawings not a scale.
Unit VCH 45 AB VCH 60 AB A B C D E

* No clearance required if air ducted

1 641 1 641

2 240 2 240

778 778

148 148

945 945

95 95

945 945

38 38

389 389

38 38

1044 1044

140 140

2 060 2 060

23 23

VCH 75-90 AB
600 D E F G 600 * 600 600

Electrical electrical connections connections Piping piping connections


C B

Minimum clearance
All dimensions in mm. Drawings not a scale.
Unit VCH 75 AB VCH 90 AB A B C D E

* No clearance required if air ducted

1 794 1 794

2658 2658

897 897

148 148

1155 1155

95 95

1155 1155

30 30

389 389

37 37

1 200 1 200

138 138

2479 2479

23 23

Packaged Equipment & Large Split Systems

york air-conditioning products

142/143

Comprehensive Building Solutions


metasys building automation and control systems

york air-conditioning products

Metasys Building Automation and Control Systems


Metasys building management system from Johnson Controls ensures all of the building systems comfort controls, lighting, fire safety, security and HVAC equipment operate together in harmony. With an innovative, IT-based infrastructure, software and wireless capabilities, Metasys is the one building management system that coordinates and organizes all the information logically to deliver it where and when needed, giving more control and easier access to information than any other system of its kind. Already the winner of the 2009 Frost & Sullivan North American BAS Market Leadership Award, Metasys now offers even more.
Ease of use
Easy to configure and deploy No special training is required to use it Enhanced Ready Access Portal (RAP) graphics capability, combined with the tenant user setup capabilities, deliver targeted views of data to any building occupants. Its also now compatible with Apple iPhone or iPod Touch platforms.

More efficiency, less costs


The Energy Essentials leverages the Metasys Advanced Reporting System to take the existing data and present it in an organized and informative way, providing easy-to-configure, easy-to-use and actionable energy reports The improved Johnson Controls Central Plant Optimization 10 (CPO 10) helps facility managers operate their chiller plants more efficiently. CPO algorithms are used to operate and sequence plant equipment in an efficient and reliable manner, and to ensure that runtime, starts and stops are equalized across the individual plant components saving energy and improving reliability in the facility.

144/145

Single platform communication


Enhanced, single platform interface of thousands of different hardwired and wireless systems, devices and equipment. Even more control options and better information access by users, thanks to: Field Equipment Controllers redesigning Terminal Equipment Controller updates and improvements Added wireless and network sensors Enhanced software and firmware

Wireless Capabilities
Increased control flexibility, streamlines retrofits and faster download times, thanks to the latest wireless technologies that Metasys incorporates into more devices. At systems user interface, network automation, field controller or room sensing levels, Wireless Building Technologies from Johnson Controls always result in increased application flexibility and cost effectiveness.

Security features
Metasys now incorporates P2000 Security Management System, whose software and network controllers ensure the safety of employees and security of company assets.

P2000

Badging Station

P2000
Server

P2000 CCTV

Work Station

IP Network RS485 / IP
Converter 2 Doors Controller CK721 Up to 16 Readers Intrusion

DVN 5000

P2000 open integration platform, designed for interoperability with a variety of security subsystems including access control, alarm & intrusion detection, video surveillance, visitor management.

S321 S300

S300

Manufacturer reserves the rights to change specifications without prior notice.

Comprehensive Building Solutions

CD Rom 2012 :

Commercial Leaflets, Technical Library, Software Tools and more...

CD available at Johnson Controls office

york air-conditioning products

m-cd-g2012

Residential & Light Commercial 2012

Minimum system requirements


Operating system Windows 98 or better Pentium II processor or superior 32 MB of RAM Screen resolution 800 x 600 pixels, 16 bits To view all pdf files, the Adobe Acrobat Reader program is required. If said program is not installed, install the one included in this CD-ROM.

Multi-language Technical Information

easy-direct-clear

About Johnson Controls


Johnson Controls delivers products, services and solutions that increase energy efficiency and lower operating costs in buildings for more than one million customers. Operating from 500 branch offices in more than 150 countries, the company is a leading provider of equipment, controls and services for heating, ventilating, air-conditioning, refrigeration and security systems. Johnson Controls is involved in more than 500 renewable energy projects including solar, wind and geothermal technologies. Its solutions have reduced carbon dioxide emissions by 13.6 million metric tons and generated savings of $7.5 billion since 2000. Many of the worlds largest companies rely on Johnson Controls to manage 1.5 billion square feet of their commercial real estate.

PUBL-6912

Johnson Controls, 2012

www.johnsoncontrols.com

E-CAT-LC-G2012 http://www.johnsoncontrols.co.uk

Johnson Controls reserve the right, in line with continuing research and development, to amend or change specifications without notice.