NOTES

3
200 i.c 700 200 1,800 200 2,600 3,000 200 900 2,800 2,000

14,900 170 i.c 1,500 gt


gt

3
200 3,000 2,000 700 200 3,500 3,700 1,750 200 200 200 200 1,800 200 1,200 200 11,200 1,200 200 750 2,800 2,000 200 1,100 3,000 2,000 700 1,750 200 200
GENERAL
All dimensions are in mm unless otherwise specied. Drawing are not to scalled. only gured dimensions to be used The contractor must check and verify all dimensions before commencement of any work. Any discrepancies to be claried with the Project Architect.

PV

PV

200

930

2,350

900 500 900

PV

PV

PV
200

1,800

PV

1,800

900

STORE
PV

1,800

To septic tank Dhobi


PV

CONSTRUCTION
All slab at ground level to be cast over 1000 guage polythene sheet on 50mm thick murram blinding on hardcore.

3,800

1,100

200

200

200

1,800

closets

200

Kitchen ceramic tiles GUEST BED RM.


200 3,200 200 1,200 200 800 200 F

closets

w/c & bath

w/c & bath

BEDROOM 1

200

200

PV

CIVIL
All soil under slab around and under foundation to be treated All soil on cut embararkment to be stablized.The slope not to for termite control. exceed 45 degree.

1,800

3,000

2,000

2,700

200

200

closets
PV PV PV
1,000

3,050

PV

DINING
5,000 200

BEDROOM 2

STRUCTURAL
All black cotton soil to be removed from all buildings and paved surfaces For all R.C work,refer to stuctural Engineer's details.

650

200

9,900

9,900

1,200

3,500

gt

900

i.c

2,900

ic
gt

200

800

200 600 1,500

1,200

200

11

1,550

1,100

PV
200

1,800

10

balcony

200

1
500 200 2,000 2,700 200 1,000 1,100 200

200

200

1
R 950
200 3,200 200

200

1,950

1,000

2,000 200

2,400 5,000

1,500

150 200

3,300 3,500 3,700

250 200

R 1,250
200

balcony

200

PV

PV

2,200 11,200

GROUND FLOOR
32,000
roof pitch = 45deg clay roofing tiles on,50x38mm timber battens at 300mm c/c on polythene sheet underlay on, 100x50mm rafters. 100x50mm treated wallplate.
200mm thick parapet wall painted to approval

FIRST FLOOR
200mm thick parapet wall painted to approval
i.c i.c
gt

roof pitch = 45deg clay roofing tiles on,50x38mm timber battens at 300mm c/c on polythene sheet underlay on, 100x50mm rafters. 100x50mm treated wallplate.

i.c

15,950

gt

200mm thick masonery walls with plastered and painted texture to approval 450mm deep r.c. beam plastered and painted to approval

200mm thick masonery walls with plastered and painted texture to approval

200mm thick natural stone walls keyed to approval

200mm thick natural stone walls keyed to approval

ELEVATION 01

ELEVATION 03

A 800 800 800 800 800 800 800 800 800

B 1000 1400 1400 1600 1600 3600 5600 7600 8800

C 1000 1200 1200 1400 1400 1800 2800 3800 4400

D 3000 3600 3600 4000 4000 5600 8600

E 800

F1

F2

150

600

VARIES (3-6M)

100

150

200mm thick parapet wall painted to approval

roof pitch = 45deg clay roofing tiles on,50x38mm timber battens at 300mm c/c on polythene sheet underlay on, 100x50mm rafters. 100x50mm treated wallplate.

200mm thick parapet wall painted to approval

roof pitch = 45deg clay roofing tiles on,50x38mm timber battens at 300mm c/c on polythene sheet underlay on, 100x50mm rafters. 100x50mm treated wallplate.

roof pitch = 35deg clay roofing tiles on,50x38mm timber battens at 300mm c/c on polythene sheet underlay on, 100x50mm rafters. 100x50mm treated wallplate.
200mm thick parapet wall with p.c.c copping painted to approval

200mm thick parapet wall painted to approval

stairs

entry lobby

bedroom 1

600

200mm thick masonery walls with plastered and painted texture to approval

200mm thick masonery walls with plastered and painted texture to approval

200mm thick masonery walls with plastered and painted texture to approval

200

200

450mm deep r.c. beam plastered and painted to approval 200mm thick natural stone walls with horizontally raked joints to approval
200mm thick natural stone walls keyed to approval

Staircase details to S.E's details Tread= 250mm Riser = 150mm

entry lobby

200

300

F2

ELEVATION 04

ELEVATION 02

25mm thick floor screed on, 150mm thick floor slab on approved dpm and hardcore infills to S.E's details

500

Invert level of incoming drain

200

500

SECTION X-X
Scale 1: 100

concrete strip foundation (depths to be determined on site)

190mm thick masonry stone wall with 10mm rendering to approval

F1

steel casement window to schedule

steel casement window to schedule

i.c
18 17 16 15 14 13 12 11 10

SITE PLAN

TYPPE

CAPACITY IN LITRES 3000 6000 9000 12000 15000 22500 45000 67500 90000

NO. OF PERSONS

A B C D E F G H I

200

800 200

steel casement window to schedule

Kitchen
Inlet manhole

PV

12

800

2,000

1,500

1,000 11
12 10

ENTRY

13

PV

14

14 13

4,300

4,300

200

PV

4,650

15

16

17

LOUNGE sunken lounge

18

PV

w/c & bath

1,800

11,850

PV

PV
18 17 16 15

200

200

PV

ENTRY LOBBY

PV

CAR PORT 6x3.5m

MASTER BEDROOM

entry lobby

9,900

200 4

PV

Depth of foundation to be detemined on site to S.E's aproval All walls to be reinforced with loop iron at every every alternate course.

200

200

MECHANICAL
All adjacent R.C. work and masonry walls to be tied with loop iron All plumbing and drainage to comply with relevant local authority

FAMILY ROOM
2,000 1,700

at every alternate course. SVP denotes soil vent pipe to be provided at the head of the drainage system Drains pass beneath buildings & driveways to be encased in 150mm concrete surround. The storm drain pipes to comply with BS 556 specication. All underground foul and waste drain pipes shall be uPVC to comply with BS 5255. All inspection chambers covers and framing shall be cast iron. Minimum slope in the drains pipes to be 1 in 100 No chases will be allowed for pipes. Sleeves will be allowed with

3 4 6 9

2,200

PV

PV

written approval of structural Eng's. No cutting of concrete without All testing of pipes must be completed before plastering. express approval of the Architect or structural Eng. All mechnical works must be co-odinated with electrical and any conict must be claried before work begin. PV denotes permanent ventilation

2,950 11,200

3,500

200 550 200


ELECTRICALS
All conduits must be laid before plastering

REVISIONS

ROOF PLAN
600x450mm MH cover & frame
NOTES

DESLUDGING INTERVAL (YEARS) 2 2 2 2 2 1.5 1.5 1.5 1.5

DIMENSIONS IN MM

150mm rc cover slab


GL GL
GENERAL All dimensions are in mm unless otherwise specied. Drawing are not to scalled. only gured dimensions to be used

10 20 30 40 50 100 200 300 400

1200 1400

3M
inlet

140mm thick masonry wall 1:3:6 conc.

The contractor must check and verify all dimensions before with the Project Architect. CONSTRUCTION

commencement of any work. Any discrepancies to be claried

Project Title

All slab at ground level to be cast over 1000 guage polythene sheet on 50mm thick murram blinding on hardcore. CIVIL

1400 1500 1400 1800 1500 1400 2000 1500 1300 2400 1500 1200 3000 1850 1500 3600 2040 1500

All soil under slab around and under foundation to be treated All soil on cut embararkment to be stablized.The slope not to for termite control. exceed 45 degree.

PROPOSED 4 BEDROOMED MAISSONATTE PLOT LR. NO. ................................

STRUCTURAL All black cotton soil to be removed from all buildings and paved surfaces For all R.C work,refer to stuctural Engineer's details. Depth of foundation to be detemined on site to S.E's aproval All walls to be reinforced with loop iron at every

Client:

200mm dia. stone blocks for loose ground or where specified

every alternate course.

MECHANICAL All adjacent R.C. work and masonry walls to be tied with loop iron All plumbing and drainage to comply with relevant local authority at every alternate course. SVP denotes soil vent pipe to be provided at the head of the drainage system

11600 4000 2260 1500 13400 4600 2380 1500

MR KARUKU MWATHI P.O BOX .................. KIKUYU

Typical section
NB. 1.Soak pits o be used on soils with good absorption eg sand,red soil etc 2.Depth to be specified

Drains pass beneath buildings & driveways to be encased in 150mm concrete surround. The storm drain pipes to comply with BS 556 specication. All underground foul and waste drain pipes shall be uPVC to comply with BS 5255. All inspection chambers covers and framing shall be cast iron. Minimum slope in the drains pipes to be 1 in 100 No chases will be allowed for pipes. Sleeves will be allowed with written approval of structural Eng's. No cutting of concrete without All testing of pipes must be completed before plastering. express approval of the Architect or structural Eng. All mechnical works must be co-odinated with electrical and any conict must be claried before work begin. PV denotes permanent ventilation

Architect:

200

800 200

100

100

ELECTRICALS All conduits must be laid before plastering

REVISIONS

Floor plan
125mm RC cover slab to engineer's detail 600x450mm cover and frame

SOAK PIT Floor plan


600x450mm cover and frame

12mm dia. ms bars at 150mm c/c bothways

ARCHISMART CREATIONS LTD Architects, Landscape & Interior Designers.

Project No. DWG TITLE: Architect/Checked By:

TWL

Outlet manhole

Project Title

Client:

Sub-soil drain
E
Architect:

10mm water proofing rendering to approval


Project No. DWG TITLE:

ARCHISMART CREATIONS LTD Architects, Landscape & Interior Designers.

Drawn By: Scale; Date:


Job No:

P.K.M
1:100
Job No: Sheet No:

Architect/Checked By:

Section A-A

150mm thick base slab

Drawn By: Scale; Date:

SEPTIC TANK DETAILS

Section B-B

Sheet No:

NOV. 2010

NOV. 2010