LP , MP & SP Series
General Features: Supplied as a complete unit,which is ready for use. Complete system available with prefiltration and final filtration. Even if power fails it giving uninterrupted air flow. Least maintenance required. Low initial cost.The heatless method contribute to low maintenance and is most reliable. They are self-regenerative and produce low levels of noise. The specially designed digital electronic control for the variable cycle of adsorptiondryer allows automatic switching off of the regeneration air. This resulting in lower cost expenditure. Designed for efficient working with least pressure drop. Secure operation by performance regulation Secure operation with implemented performance control All components requiring maintenance can easily be accessed from one side The specially designed high-efficiency dryers can be used in all applications and the regeneration air flow can be adjusted to suit the particular operating Conditions.Therefore running cost reduced. Heavy duty Purge exhaust Silencer for quite operation. Control panel,designed in a proper way,thus giving a better access to the control elements and to the displays Highly accurate electronic timer. Designed to meet the requirements of ISO 7183. Dried air as per requirements of ISO 8573-1 class 3-3-4. Painted for aesthetic look and additional protection. Easy to operate. No moving parts and hence high reliability. Electronic timer enables accurate cycle timing. It requires only 230V,ac power supply to operate the system.

High Pressure air Dryer

Applications :
Instrument & Control Air Process Control Instruments Textile Machines Machine tools Bearing air Air Motors & Heavy Air motor miniature Packaging machine Pneumatic cylinder Sensors in fluid technology Sand blasting unit Handling of food and beverages Semi conductor manufacturing Wind tunnels Pharmaceutical manufacturing Conveyance of hygroscopic products Paint spray & Powder coating
GENERAL SPECIFICATIONS

fil t
Scfm End Conn. BSP

er
Power Supply Volts/Hz

Model
Series LP LP-68 LP-115 LP-195 LP-382 LP-635 Series -MP MP-100 MP-150 MP-200 MP-250 MP-300 MP-400 MP-500 MP-600 MP-1100 Series-SP SP-125 SP-225 SP-325 SP-425 SP-525

Capacity at 1 bar,20C LPM M3/Hr

Height

Width

Depth

Weight Kg

( available pressure rating from 100 bar to 250 bar @ regeneration air loss of 4 to 5.5% max ) 58 1/4 100 1666 220 / 50-60 88 3/8 150 2500 220 / 50-60 117 3/8 200 3333 220 / 50-60 150 3/8 250 4166 220 / 50-60 176 3/8 300 5000 220 / 50-60 235 400 6666 220 / 50-60 295 500 8333 220 / 50-60 350 600 10000 220 / 50-60 650 3/4 1100 18333 220 / 50-60 ( available pressure rating from 250 bar to 400 bar @ regeneration air loss of 4 to 5.5% max ) 74 1/4 125 2083 220 / 50-60 132 3/8 225 3750 220 / 50-60 190 3/8 325 5417 220 / 50-60 250 425 7083 220 / 50-60 310 3/4 525 8750 220 / 50-60

an

( available pressure rating from 40 bar to 100 bar @ regeneration air loss of 4 to 5.5% max ) 40 1/4 68 1133 220 / 50-60 68 3/8 115 1916 220 / 50-60 115 3/8 195 3250 220 / 50-60 225 382 6366 220 / 50-60 375 3/4 635 10583 220 / 50-60

1325 1450 1575 2125 2175 1350 1420 1540 1410 1480 1560 1620 1830 2110 1320 1380 1440 1580 1620

625 625 625 850 850 625 625 625 725 725 875 875 875 875 650 650 650 650 875

450 450 450 525 525 475 475 475 475 475 550 550 550 550 475 475 475 475 650

50 60 92 116 162 65 78 96 104 150 165 185 240 290 103 130 148 160 240

Desiccant tower with corrosive protection. Stainless-steel support screens and air diffusers. Large desiccant bed, ensures to produce -40C dew point Each tower is provided with pressure gauge Filters: Each dryer is equipped with a Pre-filter to protect desiccant from free water contamination, dust, scales and oil etc., and an after-filter to avoid desiccant dust carry over. Each filter fitted with manual condensate drain valve ,Optional automatic drain valve Pressure Gauge: Pressure gauges on each tower for easier illustration of working of dryer. Valves: Specially designed Valves, which act as main flow and exhaust valves. Check valves with well designed orifice for highly accurate purge flow.
Bossmanfilter reserves the right to modify, in any moment technical details without notice. Accessories shown in the pictures are not a part of the equipments

Bo ss

Desiccant Tower:

Optional : Power supply with 12V DC,24V DC available on request,Power consumption approx. 60Watts,Dew point -40C

For any other capacity contact factory. Due to continues improvements,specifications are subject to change without notification.
Dryer Series - LP Pressure correction factor

Op.Pre K-pre

40 0.45

45 0.45

50 0.50

55 0.55

60 0.60

65 0.65

70 0.70

75 0.75

80 0.80

85 0.85

90 0.90

95 0.95

100 1.00

Dryer Series - MP Pressure correction factor

Op.Pre K-pre

110 0.44

120 0.48

130 0.52

140 0.56

150 0.60

160 0.64

170 0.68

180 0.72

190 0.76

200 0.80

210 0.84

220 0.88

230 0.92

240 0.96

250 1.00

Dyer Series - SP Pressure correction factor

Op.Pre K-pre

250 0.63

275 0.69

300 0.75

325 0.81

350 0.88

375 0.94

400 1.00

Correction Factor for Inlet temperature

Inlet Temp. In Deg.C Ktemp

25 1.10

30 1.05

35 1.00

40 0.78

45 0.61

50 0.48

55 0.38

Dryer Model Selection guide Required Dryer Model = Air flow rate / ( Kpre x Ktemp )