Power

8.4.1

+24 V DC

This alternative is available for RBS 3206F and RBS 3206E. The incoming +24 V DC power is connected by screw terminals to the power switch in the DC Connection Unit (DCCU). Each Power Supply Unit (PSU) is connected with two cables (a pair). The power interface accepts cables with an area up to 35 mm , and a minimum cable area of 25 mm is recommended. The maximum allowed fuse rating for a cable area of 25 mm is 75 A. All cables must be multistranded. The connection interface is shown in the figure below.

Figure 22 8.4.2

+24 V DCCU

-48 V DC

RBS 3206M The incoming two-wire -48 V DC power is connected by screw terminals to a PDU-03. The power cable must be multistranded and have a cross-sectional area of 35-70 mm . The connection interface is shown in the figure below.

Figure 23 RBS 3206F

PDU-03

The incoming -48 V DC prioritized power is connected by screw terminals to a PDU-03. The power cable must be multistranded and have a cross-sectional area of 35-70 mm . The connection interface is shown in the figure below.

Figure 24

PDU-03

RBS 3206F and RBS 3206E The incoming two-wire -48 V DC power is connected by screw terminals to a DC filter. The power cable must be multistranded and have a cross-sectional area of at least 35 mm . There are two variants of the DC filter, whose connection interfaces are shown in the figure below. Note:

For an AC-powered RBS 3206, the optional battery backup is connected to the DC filter.

Figure 25 8.4.3 AC

DC Filter (Location Depends on the Type of Cabinet)

This alternative is available for RBS 3206E and RBS 3206F. The incoming AC power and protective earth are connected by screw terminals in the AC Connection Unit (ACCU). Each Power Supply Unit (PSU) is connected with two cables (a pair). The power interface accepts cables with an area between 1.5 mm and 2.5 mm . The maximum allowed fuse rating for a cable area of 2.5 mm is 16 A. All cables must be multistranded. The connection interface is shown in the figure below.

Figure 26

ACCU (Location Depends on the Type of Cabinet)

24 RU
The various radio units (RU) and their dependencies are listed in Table 27.
Table 27 RU

Unit

Supported from SW R-state P4 P5 All All R4B R4B All R4B R4B R12C All R12E R12C All R12E R12E All All R3AK R12K R12K n/a n/a R27A n/a n/a n/a
(2)

Product Number KRC 118 16/1 KRC 118 16/2 KRC 118 16/3 KRC 118 16/4 KRC 118 18/1 KRC 118 18/4 KRC 118 18/5 KRC 118 19/2 KRC 118 19/1 KRC 118 19/3 KRC 118 22/3 KRC 118 22/1 KRC 118 22/4 KRC 118 35/2 KRC 118 29/4 KRC 118 29/2 KRC 118 18/3

Lowest IBW(1) Supported [MHz] HW R-state R2A R1A R1B R1B R1B R1B R1B R1B R1A R1C R1A R1A R1D R1A R1B R1A R1B R1B 15 15 15 15 15 15 15 10 15 15 15 15 15 15 15 15 15 15

RU21 2130 [2.1 GHz, 30 W] RU21 2120 [2.1 GHz, 20 W] RU21 2120 [2.1 GHz, 20 W] RU21 2130 [2.1 GHz, 30 W] RU22 2140 [2.1 GHz, 40 W] RU22 2120 [2.1 GHz, 20 W] RU22 2140 [2.1 GHz, 40 W] RU22 2160 [2.1 GHz, 60 W ] RU22 1920 [1900 MHz, 20 W] RU22 1940 [1900 MHz, 40 W] RU22 1940 [1900 MHz, 40 W] RU22 0820 [850 MHz, 20 W] RU22 0840 [850 MHz, 40 W] RU22 0840 [850 MHz, 40 W] RU22 0860 [850 MHz, 60 W] RU22 0940 [900 MHz, 40W] RU22 21 IV20 [1700/2100 MHz, 20 W] RU22 21 IV40 [1700/2100 MHz, 40 W] RU22 2120 [2.1 GHz, 20 W]
(2) (2)

R11AF/3 KRC 118 18/6

n/a R12K n/a n/a R12K n/a n/a n/a n/a n/a n/a

R11AF/3 KRC 118 22/2

FU
The various filter units (FU) and their dependencies are listed in Table 16.
Table 16 FU

Unit

Supported from SW Rstate P4 P5 All All All All R12E R12K R12K R12K
(1)

Product Number KRC 118 17/1 KRC 118 20/1 KRC 118 21/1 KRC 118 28/1 KRC 118 36/1

Lowest Supported HW Rstate R2B R1C R1D R1B R1B

FU12 [2.1 GHz] FU12 [1900 MHz] FU12 [850 MHz] FU12 [1700/2100 MHz] FU 12 [900 MHz]