2.2
In the following tables are listed all the items of the equipment Such tables report the following information: ITEM DESCRIPTIONName of part ITEM CODEASB factory Part Nos. (Such as 411.xxx.xxx x) of item MODULEName of the module in item CODEASB factory Part number of module QTYquantity Max QTYMaximum quantity
Table12.
ITEM CODE
MODULE
CODE
3AL97081ACAA
SSY-Main Unit 24
3AL97081ADAA
SSY-MB4-1
3AL97273AAAA
BPA-Backplane MA-1642EMUX Mechanical Box PBA-PBP48 BPA-Backplane MA-1642EMUX Mechanical Box PBA-PBP24 PBA-MB4-1 MA-FRONT PANEL MB4-1 CON-ACCESS*SCREW LOCKS MPP - 11 X 45 LABEL
3AL97028AAAA
--
--
1AB036130001 4 3AN49331AAAA 1 3AL97215AAAA 3AL97213AAAA 3AL97051AAAA 21103879AADA 1AD052840001 1AD003150013 3AL97215AAAA 3AL97213ABAA 3AL97051AAAA 21103879AADA 1AD052840001 1AD003150013 3AL97215AAAA 3AL97213ACAA 3AL97051AAAA 21103879AADA 1AD052840001 1AD003150013 2 2 2 2 4 8 2 2 2 2 4 8 2 2 2 2 4 8 2,3,4,5
3AL97083CAAA
PBA-OT1B1(N)(CD) PBA-OMS11 MA-OT1B1 complete panel MPP-LABEL COPPER SUPPORT_10.5 SCREW*PAN-HD*XR-POZ PBA-OT1B1(N)(CD) PBA-OML11 MA-OT1B1 complete panel MPP-LABEL COPPER SUPPORT_10.5 SCREW*PAN-HD*XR-POZ
PBA-OT1B1(N)(CD) PBA-OML12 MA-OT1B1 complete panel MPP-LABEL COPPER SUPPORT_10.5 SCREW*PAN-HD*XR-POZ
3AL97083CBAA
2,3,4,5
3AL97083CCAA
2,3,4,5
ED
01
58/176
SSY-E1RCB8 SSY-E1B28 SSY-E1B8 SSY-DE1B28 SSY-DE1B8 SSY-DE1JB8 SSY-SE1B28 SSY-SE1B8 SSY-SDE1B28 SSY-SDE1B8 SSY-DE1B32 SSY-E3B1 SSY-DS3B1
3AL97045AAAA 3AL97078AAAA 3AL97078ABAA 3AL97079AAAA 3AL97079ABAA 3AL97079DBAA 3AL97078ACAA 3AL97078ADAA 3AL97079ACAA 3AL97079ADAA 3AL97198AAAA 3AL97086AAAA 3AL97086ABAA
PBA-OT1B1(N)(CD) PBA-EM1 MA-OT1B1 complete panel MPP-LABEL COPPER SUPPORT_10.5 SCREW*PAN-HD*XR-POZ PBA-E1RCB8 MA-E1RCB8 complete panel PBA-E1B28 MA-E1B28 Complete panel PBA-E1B8 MA-E1B8 Complete panel PBA-DE1B28 MA-DE1B28 Complete panel PBA-DE1B8 MA-DE1B8 Complete panel PBA-DE1JB8 MA-DE1JB8 Complete panel PBA-SE1B28 MA-E1B28 Complete panel PBA-SE1B8 MA-E1B8 Complete panel PBA-SDE1B28 MA-DE1B28 Complete panel PBA-SDE1B8 MA-DE1B8 Complete panel PBA-DE1B32 MA-DE1B32 Complete panel
PBA-E3B1 MA-E3B1 complete panel PBA-DS3B1 MA-DS3B1 complete panel PBA-ISA-ES1 8FE MA-ISA-ES1 8FE complete panel PBA-ISA-ES1 3FE MA-ISA-ES1 3FE complete panel PBA-DC48B MA-DC48B complete panel PBA-AC220B MA-AC220B complete panel PBA-FB MA-FB complete panel PBA-SFB MA-SFB complete panel
3AL97215AAAA 3AL97213ADAA 3AL97051AAAA 21103879AADA 1AD052840001 1AD003150013 3AL97035AAAA 3AL97050AAAA 3AL97060AAAA 3AL97055AAAA 3AL97060ABAA 3AL97055ACAA 3AL97062AAAA 3AL97055ABAA 3AL97062ABAA 3AL97055ADAA 3AL97062DBAA 3AL97225AAAA 3AL97060ACAA 3AL97055AEAA 3AL97060ADAA 3AL97055AGAA 3AL97062ACAA 3AL97055AFAA 3AL97062ADAA 3AL97055AHAA 3AL97197ABAA 3AL97204AAAA 3AL97085AAAA 3AL97120AAAA 3AL97085ABAA 3AL97120ABAA 3AL97164ABAA 3AL97174AAAA 3AL97193ABAA 3AL97195AAAA 3AL97016ABAA 3AL97054AAAA 3AL97058AAAA 3AL97056AAAA 3AL97053AAAA 3AL97053ABAA
2 2 2 2 4 8 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 2 2 2 2 1 1 1 1
2,3,4,5
2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5 2,3,4,5
2,3,4,5
6 6 7 7
3AL97047ACAA 1 1 1 3AL97047ADAA 1
ED
01
59/176
2.3
Connection layout
There are seven slots in the 1642EMUX equipment. As indicated in Figure25. , the slot (1) is the main board slot; slots (2)-(5) are service board slots, in which different types of service boards can be inserted; slot (6) is the power supply interface board slot ,slot (7) is the fan board slot and slot(8) is anti-dust board.
Table14. Note 1 2
Explanatory notes Description SSY-MB4-1 is the main board without SFP interface module, can work in STM1 (S1.1/L1.1/L1.2), or STM4(S4.1/L4.1/L4.2) optical interface mode, TM or ADM mode by the choice of optional SFP module independently The double shield DC48V power cable for EMC/EMI Class B qualification
ED
01
61/176
2.4
Acronym AC220B
Slots 6
(1)
(2)
Note: (1) Power supply switch ON means the power supply switch is in the connected status. OFF means the power supply switch is in the disconnected status. (2) 220V/230V AC power supply interface, D 3-terminal connector.
ED
01
62/176
Acronym DC48B
Slots 6
(2)
(5)
Note: (1) Power supply switch ON means the power supply switch is in the connected status OFF means the power supply switch is in the disconnected status (2) (3) (4) (5) 24V/48V DC power supply interface, D 3-terminal connector. The voltage label on the power supply connector terminal -24V/48V; The voltage label on the power supply connector terminal protective grounding; The voltage label on the power supply connector terminal GND;
ED
01
63/176
Acronym FB/SFB
Slots 7
FB panel view
Note: (1) 24V/48V DC power supply interface, D 3-terminal connector. (2) The voltage label on the power supply connector terminal GND; (3) The voltage label on the power supply connector terminal protective grounding; (4) The voltage l label on the power supply connector terminal -24V/48V; Figure28. FB/SFB board, panel view
ED
01
64/176
(4)
(5)
(1) RUN LED (2) COMMON ALARM (3) SERIAL ALARM (4) Q PORT (5) F PORT (6) Port #1 E2 channel (7) Port #1 F1 channel (8) Port #2 E2 channel (9) Port #2 E2 channel (10) Housekeeping input0 (11) Housekeeping input1 (12) Housekeeping input2 (13) Housekeeping output0 (14) Housekeeping output1 (15) Housekeeping output2 (16) Debug port (17) 2M external clock output (18) 2M external clock input (19) OWM connector (20) OWM LED (21) OT1 alarm LED (22) OT2 alarm LED (23) OT1 output (24) OT1 input (25) Reset button (26) OT2 output (27) OT2 input
(9)
(23) (24)
(25)
(26) (27)
65/176
Acronym OT1B1
Slots 2,3,4,5
(1)
Note: (1)
(2)
(3)
(4)
(5)
Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED ON-common alarm
(2), (3) RJ11 connector: Transparent channel F1 byte, E2 byte. (4), (5) SC/PC optical fiber connector: RX, TX.
ED
01
66/176
Acronym ET1B1
Slots 2,3,4,5
(1)
(2)
(3)
(4)
(5)
Note: (2)
Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED ON-common alarm
(2), (3) RJ11 connector: Transparent channel F1 byte, E2 byte. (4), (5) 1.0/2.3 coaxial connector: RX, TX.
In order to get better EMC performance, additional shield box for coaxial cable is required,see following.
ED
01
10
67/176
Acronym DE1B28
Slots 2,3,4,5
(1)
(2)
Note: (1) Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED ON-common alarm (2) 2M service interface. The upper is the transmitting terminal and the lower is the receiving terminal.
ED
01
11
68/176
Acronym DE1B8
Slots 2,3,4,5
(1)
(2)
Note: (1) Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED-common alarm (2) 2M service interface. The upper is the transmitting terminal and the lower is the receiving terminal.
ED
01
12
69/176
Acronym E1B28
Slots 2,3,4,5
(1)
(2)
Note: (1) Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED-common alarm (2) 2M service interface: The upper is the transmitting terminal and the lower is the receiving terminal.
ED
01
13
70/176
Acronym E1B8
Slots 2,3,4,5
(1)
(2)
Note: (1) Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED-common alarm (2) 2M service interface: The upper is the transmitting terminal and the lower is the receiving terminal.
ED
01
14
71/176
Acronym DE1B32
Slots 2,3,4,5
(1)
(2)
Note: (3) Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED ON-common alarm (4) 2M service interface. The upper is the transmitting terminal and the lower is the receiving terminal.
ED
01
15
72/176
Acronym E1RCB8
Slots 2,3,4,5
(1)
(2)
(3)
Note: (1) Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED-common alarm (2) 2M service interface. The upper is the transmitting terminal and the lower is the receiving terminal. (3) 2M extended service interface for transmitting ECC signals. TX stands for transmitting terminal and RX stands for receiving terminal.
ED
01
16
73/176
Acronym DS3B1
Slots 2,3,4,5
(1)
(2) (3)
Note: (1)
Tricolor LED Green LED ON-units in operation Red LED ON-severity alarm Yellow LED-common alarm
ED
01
17
74/176
Acronym E3B1
Slots 2,3,4,5
(1)
(2) (3)
Note: (1)
Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED-common alarm
ED
01
18
75/176
Slots 2,3,4,5
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10) (11) Note: (1) Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED ON-common alarm (2)~(9) RJ45 connector: Ethernet port 1-8. (10) Ethernet interface LINK/ACTIVE status indicating lamp: - ON means LINK status; - Flash means ACTIVE status. (11) Ethernet interface 10M/100M rate indicating lamp: - OFF means 10M rate - ON means 100M rate
ED
01
19
76/176
Slots 2,3,4,5
(1)
(2)
(3)
(4)
(5) Note: (1) Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED ON-common alarm (2) SFP optical connector: Ethernet port 1. (3)(4) RJ45 connector: Ethernet port 2~3.
(6)
(5) Ethernet interface LINK/ACTIVE status indicating lamp: - ON means LINK status; - Flash means ACTIVE status. (6) Ethernet interface 10M/100M rate indicating lamp: - OFF means 10M rate - ON means 100M rate
ED
01
20
77/176
Acronym DE1JB8
Slots 2,3,4,5
(1)
(2)
Note: (1)Tricolor LED: Green LED ON-units in operation Red LED ON-severity alarm Yellow LED-common alarm (2)2M service interface.
ED
01
21
78/176
Nominal bit rate Application code Operating wavelength Range Transmitter reference point S Source type Spectrum characteristics: Maximum RMS () spectrum width Maximum -20 dB spectrum width Minimum side form suppression ratio Mean launch power Maximum Minimum Minimum extinction ratio Optical path between S and R Attenuation range Maximum dispersion Minimum return loss of the optical cable at point S (including any active connector) Maximum discrete reflection coefficient between SR points Receiver at reference point R Minimum sensitivity Minimum overload Maximum optical path penalty Maximum reflection measured at point R Note: NA indicates not available.
kbit/s nm
155 520 (ITU-T G.707) L-1.1 L-1.2 1263-1360 1480-1580 MLM 3 0 -5 10 10-28 246 NA NA -34 -10 1 NA MLM 1 30 0 -5 10 10-28 NA 20 -25 -34 -10 1 -25
Table22.
Nominal bit rate Application code Operating wavelength Range Transmitter reference point S Source type Spectrum characteristics: Maximum RMS () spectrum width Maximum -20 dB spectrum width Minimum side form suppression ratio Mean launch power Maximum Minimum Minimum extinction ratio Optical path between S and R Attenuation range Maximum dispersion Minimum return loss of the optical cable at point S (including any active connector) Maximum discrete reflection coefficient between SR points Receiver at reference point R Minimum sensitivity Minimum overload Maximum optical path penalty Maximum reflection measured at point R Note: NA indicates not available.
ED
01
22
135/176