I. Introduction Wire and connect one bulb controlled by one single pole flush type switch. II. Circuit Diagram

III. Tools/Materials Needed A. Tools Screwdriver Cutter Long Nose Pliers Hammer IV. Procedure 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Make or prepare the job plan. Prepare the materials that will be needed. Determine Fasten the junction and utility boxes in place. Measure and cut the wire that will be needed. Insert the wire inside the molflex tube allowing 6 inches allowance of the wire. Make the necessary connection or connect the terminals. Place the connected inside each box Make the necessary connection inside the junction box. Place the bulb and energize the circuits to a 220V power supply. B. Materials 3 Junction Box 3 Utility Box 2 Bulb Sockets 2 Flush Type Switch 1 - Flush type Convenient Outlet 12 Clamp Connector 6 C-Clamps 6 Solderless Connector

Name: Date:

Year & Section:

Job # 2
I. Introduction Wire and connect two bulbs in series controlled by a single pole flush type switch. II. Circuit Diagram

III. Tools/Materials Needed A. Tools Screwdriver Cutter Long Nose Pliers Hammer IV. Procedure 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Make or prepare the job plan. Prepare the materials that will be needed. Determine Fasten the junction and utility boxes in place. Measure and cut the wire that will be needed. Insert the wire inside the molflex tube allowing 6 inches allowance of the wire. Make the necessary connection or connect the terminals. Place the connected inside each box Make the necessary connection inside the junction box. Place the bulb and energize the circuits to a 220V power supply. B. Materials 3 Junction Box 3 Utility Box 2 Bulb Sockets 2 Flush Type Switch 1 - Flush type Convenient Outlet 12 Clamp Connector 6 C-Clamps 6 Solderless Connector

Name: Date:

Year & Section:

Job # 3
I. Introduction Wire and connect two bulbs in parallel controlled by a single pole flush type switch. II. Circuit Diagram

III. Tools/Materials Needed A. Tools Screwdriver Cutter Long Nose Pliers Hammer IV. Procedure 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Make or prepare the job plan. Prepare the materials that will be needed. Determine Fasten the junction and utility boxes in place. Measure and cut the wire that will be needed. Insert the wire inside the molflex tube allowing 6 inches allowance of the wire. Make the necessary connection or connect the terminals. Place the connected inside each box Make the necessary connection inside the junction box. Place the bulb and energize the circuits to a 220V power supply. B. Materials 3 Junction Box 3 Utility Box 2 Bulb Sockets 2 Flush Type Switch 1 - Flush type Convenient Outlet 12 Clamp Connector 6 C-Clamps 6 Solderless Connector

Name: Date:

Year & Section:

Job # 4
I. Introduction Wire and connect two bulbs controlled by individual single pole flush type switch. II. Circuit Diagram

III. Tools/Materials Needed A. Tools Screwdriver Cutter Long Nose Pliers Hammer IV. Procedure 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Make or prepare the job plan. Prepare the materials that will be needed. Determine Fasten the junction and utility boxes in place. Measure and cut the wire that will be needed. Insert the wire inside the molflex tube allowing 6 inches allowance of the wire. Make the necessary connection or connect the terminals. Place the connected inside each box Make the necessary connection inside the junction box. Place the bulb and energize the circuits to a 220V power supply. B. Materials 3 Junction Box 3 Utility Box 2 Bulb Sockets 2 Flush Type Switch 1 - Flush type Convenient Outlet 12 Clamp Connector 6 C-Clamps 6 Solderless Connector

Name: Date:

Year & Section:

Job # 5
I. Introduction Wire and connect two bulbs controlled by separate single pole flush type switch. II. Circuit Diagram

III. Tools/Materials Needed A. Tools Screwdriver Cutter Long Nose Pliers Hammer IV. Procedure 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Make or prepare the job plan. Prepare the materials that will be needed. Determine Fasten the junction and utility boxes in place. Measure and cut the wire that will be needed. Insert the wire inside the molflex tube allowing 6 inches allowance of the wire. Make the necessary connection or connect the terminals. Place the connected inside each box Make the necessary connection inside the junction box. Place the bulb and energize the circuits to a 220V power supply. B. Materials 3 Junction Box 3 Utility Box 2 Bulb Sockets 2 Flush Type Switch 1 - Flush type Convenient Outlet 12 Clamp Connector 6 C-Clamps 6 Solderless Connector