You are on page 1of 4

GENERAL SPECIFICATIONS CENTRALIZED MODELS

ULTRA-700.0-TL ULTRA-1050.0-TL ULTRA-1400.0-TL

The largest solar power inverter in the Power-One Aurora product range, the new UTLTRA-1400.0 unit is designed with large utility-grade installations in mind. This liquid-cooled, high-powered Aurora inverter is the largest PV inverter available in the market. The compact chassis gives maximum power for the minimum footprint. Industry-leading power conversion efficiencies of up to 98.7%, combined with high-speed Maximum Power Point Tracking (MPPT) channels, optimize energy harvesting across a wide array of operating conditions. Up to four independent MPPT input channels oer maximum flexibility and energy harvesting. This large inverter system significantly reduces the wiring requirements and on-site testing thanks to the presence of separated and dedicated compartments for DC and AC.

Features
High performance utility grade inverter for large utility PV installations with 98.7% efficiency Outdoor enclosure for unrestricted use under any environmental conditions Passive liquid cooling with total segregation of internal compartments assuring a 5-year maintenance cycle Reduced susceptibility to a single fault. In case of a component failure, a maximum of 350kW will be lost Extended MPPT input voltage range Direct transformerless conversion to the 690 Vac output reduces AC distribution cost Maximum input voltage up to 1100 Vdc, high design flexibility and reduced DC distribution losses for large scale PV plants Integrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not required Easy installation and maintenance procedure. Front extractible DC/AC converters and accessibility to all critical parts Ethernet communication and two independent RS-485 communication interfaces for inverter and intelligent string combiner monitoring Compliant to BDEW and FERC 661
AURORA ULTRA 1

CORE PLUS ULTRA

ULTRA

BLOCK DIAGRAM OF ULTRA-1400.0-TL

PV ARRAY 1(+) PV ARRAY 2(+) PV ARRAY 3(+) PV ARRAY 4(+) PV ARRAY 5(+) PV ARRAY 6(+) PV ARRAY 1(-) PV ARRAY 2(-) PV ARRAY 3(-) PV ARRAY 4(-) PV ARRAY 5(-) PV ARRAY 6(-)

INVERTER MODULE 350kW DC BREAKER OVR BULK CAPS MODULE DC / AC INVERTER MODULE LINE FILTER MODULE AC CONTACT MODULE EMI FILTER AC FUSE

CONTROL CIRCUIT

INVERTER MODULE 350kW OVR DC BREAKER BULK CAPS MODULE DC / AC INVERTER MODULE LINE FILTER MODULE AC CONTACT MODULE EMI FILTER

PV ARRAY 19(+) PV ARRAY 20(+) PV ARRAY 21(+) PV ARRAY 22(+) PV ARRAY 23(+) PV ARRAY 24(+) PV ARRAY 19(-) PV ARRAY 20(-) PV ARRAY 21(-) PV ARRAY 22(-) PV ARRAY 23(-) PV ARRAY 24(-)

Block Diagram and Efciency Curves

E ciency, %

AC FUSE

CONTROL CIRCUIT

AC BREAKER R S MAIN AC POWER CONNECTION T PE


AC CONTACT MODULE EMI FILTER AC FUSE

INVERTER MODULE 350kW OVR DC BREAKER BULK CAPS MODULE DC / AC INVERTER MODULE LINE FILTER MODULE

CONTROL CIRCUIT

INVERTER MODULE 350kW OVR DC BREAKER BULK CAPS MODULE DC / AC INVERTER MODULE LINE FILTER MODULE AC CONTACT MODULE EMI FILTER AC FUSE

TO EACH 350.0 Kw MODULE AC BREAKER 24 VDC 24 VDC - 5 VDC R S T N PE


LS1 LS2 LS3 N

AUX POWER CONNECTION

CONTROL CIRCUIT

208 VAC CONTROL CIRCUIT

PVI-ULTRA
99,0% 98,5% 98,0% 97,5% 97,0% 96,5% 96,0% 95,5% 95,0% 94,5% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 650 Vdc

% of Rated Output Power

AURORA ULTRA

PARAMETER
Input Side Absolute Maximum DC Input Voltage (Vmax,abs) MPPT Input DC Voltage Range (VMPPTmin ... VMPPTmax) at Vacr MPPT Input DC Range (VMPPTmin ... VMPPTmax) at Pacr and Vacr Number of Independent MPPT Multi-Master Number of Independent MPPT Multi - Master/Slave Maximum Combined DC Input Current (Idcmaxc) Maximum DC Input Current for Each Module (Idcmax,m) Number of DC Inputs Pairs DC Connection Type (both positive and negative polarity) Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Residual Current Protection, grounded Neutral, floating panels Fuse Size for Each Input Pair Output Side AC Grid Connection Type Rated AC Power (Pacr) Rated Grid Voltage (Vacr) AC Voltage Range (Vacmin...Vacmax) Maximum Output Current (Iacmax) Rated Frequency (fr) Frequency Range (fmin...fmax) Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type (for each phase) Output Protection Anti-Islanding Protection Output Overvoltage Protection (Varistor) Night Time Disconnect AC Switch AC Fuse for each module Operating Performance Maximum Efficiency (max) Weithted Efficiency (EURO / CEC ) Stand-by Consumption/Night-time power loss AC Auxiliary Supply Auxiliary Supply Consumption Auxiliary Supply Consumption without Cooling Inverter Switching Frequency Communication Wired Local Monitoring Remote Monitoring AURORA String Combiner User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Required Air Cooling Flow Dimension (H x W x D) Weight Weight of the module Safety Transformer Marking Safety and EMC Standard Grid Standard

ULTRA-700.0-TLOUTD-690

ULTRA-1050.0-TLOUTD-690

ULTRA-1400.0-TLOUTD-690

1000 V (1100 V opt.) 1000 V (1100 V opt.) 1000 V (1100 V opt.) 470...900 V 470...900 V 470...900 V Linear Derating from MAX to 10kW Linear Derating from MAX to 15kW Linear Derating from MAX to 20kW [850V<VMPPT<900V] 560 kW @ 470 V [850V<VMPPT<900V] 840 kW @ 470 V [850V<VMPPT<900V] 1120 kW @ 470 V 585...850 V @ 700 kW 645...850 V @ 780 kW 2 1 1240 A 620 A 12 24 x 50mm2 ...185mm2(M10) Yes, via input breaker 1 for each module 125 A / 1100 V Three phases 3W+PE 780 kVA 690 V 621...759 V (1) 650 A 50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) < 3% (@ Pac,r) 2 x 240 mm2 (M12) According to local standard Yes Yes Yes 3x350A/200kA 98.7% (4) 98.2% / 98.0% (4) < 90 W 3 x 400 Vac +N, 50/60 Hz < 0.50% of Pac,r < 0.05% of Pac,r 9 kHz 585...850 V @ 1050 kW 645...850 V @ 1170 kW 3 2 1240 A + 620 A 620 A 18 36 x 50mm2...185mm2(M10) Yes, via input breaker 1 for each module 125 A / 1100 V Three phases 3W+PE 1170 kVA 690 V 621...759 V (1) 975 A 50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) < 3% (@ Pac,r) 3 x 240 mm2 (M12) According to local standard Yes Yes Yes 3x350A/200kA 98.7% (4) 98.2% / 98.0% (4) < 110 W 3 x 400 Vac +N, 50/60 Hz < 0.40% of Pac,r < 0.04% of Pac,r 9 kHz PVI-USB-RS232_485 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) TFT LCD 5.7 -20...+ 60C/-4...140F with derating above 50C/122F -40...+ 60C/-40...140F with derating above 50C/122F (opt.) 0...100% condensing 0...100% condensing 0...100% condensing < 78 dB(A) @ 1 m < 78 dB(A) @ 1 m < 78 dB(A) @ 1 m 2000 m / 6560 ft 2000 m / 6560 ft 2000 m / 6560 ft IP 65 Passive liquid and air forced Not applicable 2920mm x 3020mm x 1520mm / 114,9 x 118.9 x 59.9 < 3000 kg / 6613 lb < 55 kg / 121 lb IP 65 Passive liquid and air forced Not applicable 2920mm x 3720mm x 1520mm / 114,9 x 146,5 x 59.9 < 3800 kg / 8377 lb < 55 kg / 121 lb IP 65 Passive liquid and air forced Not applicable 2920mm x 4420mm x 1520mm / 114,9 x 174,0 x 59.9 < 4600 kg / 10141 lb < 55 kg / 121 lb 585...850 V @ 1400 kW 645...850 V @ 1560 kW 4 2 1240 A + 1240 A 620 A 24 48 x 50mm2 ...185mm2(M10) Yes, via input breaker 1 for each module 125 A / 1100 V Three phases 3W+PE 1560 kVA 690 V 621...759 V (1) 1300 A 50/60 Hz 47...53 / 57...63 Hz (2) > 0.995 (adj. 0.90) < 3% (@ Pac,r) 4 x 240 mm2 (M12) According to local standard Yes Yes Yes 3x350A/200kA 98.7% (4) 98.2% / 98.0% (4) < 180 W 3 x 400 Vac +N, 50/60 Hz < 0.50% of Pac,r < 0.05% of Pac,r 9 kHz

Not included; recommended 10A ground fault protection with time and current adjustable

No No No CE CE CE EN 50178, EN61000-6-2, EN61000-6- EN 50178, EN61000-6-2, EN61000-6- EN 50178, EN61000-6-2, EN61000-64, EN61000-3-11, EN61000-3-12 4, EN61000-3-11, EN61000-3-12 4, EN61000-3-11, EN61000-3-12 Attachment A70 Terna(3), CEI-0-16(3), BDEW, FERC661 Attachment A70 Terna(3), CEI-0-16(3), BDEW, FERC661 Attachment A70 Terna(3), CEI-0-16(3), BDEW, FERC661

1. The AC voltage range may vary depending on specific country grid standard 2. The Frequency range may vary depending on specific country grid standard 3. Since their applicability dates 4. Power consumption of the auxiliary services not included Remark. Features not specifically listed in the present data sheet are not included in the product

AURORA ULTRA

www.power-one.com
Power-One Renewable Energy Worldwide Sales Offices Country Name/Region Australia China (Shenzhen) China (Shanghai) India Singapore Belgium / The Netherlands / Luxembourg France Germany Italy Spain United Kingdom Dubai Canada USA East USA Central USA West 4 AURORA ULTRA Asia Pacific Asia Pacific Asia Pacific Asia Pacific Asia Pacific Europe Europe Europe Europe Europe Europe Middle East North America North America North America North America Telephone +61 2 9735 3111 +86 755 2988 5888 +86 21 5505 6907 +65 6896 3363 +65 6896 3363 +32 2 206 0338 +33 (0) 141 796 140 +49 7641 955 2020 00 800 00287672 Opt. n5 +34 91 879 88 54 +44 1903 823 323 +971 50 100 4142 +1 877 261-1374 +1 877 261-1374 +1 877 261-1374 +1 877 261-1374 Email sales.australia@power-one.com sales.china@power-one.com sales.china@power-one.com sales.india@power-one.com sales.singapore@power-one.com sales.belgium@power-one.com sales.france@power-one.com sales.germany@power-one.com sales.italy@power-one.com sales.spain@power-one.com sales.UK@power-one.com sales.dubai@power-one.com sales.canada@power-one.com sales.usaeast@power-one.com sales.usacentral@power-one.com sales.usawest@power-one.com

Ver. 2012-03.1-EN - All products are subject to technical improvements without notice.