NEC Pasolink NEO Series


PDH/SDH Digital Radio System Operation

General Infromation:
This section provdies instructions for operation of the 6 to 52GHz PDH/SDH microwave Radio System. i R di S t Interface Terminals and Jacks,Control,Indicators, and Test Jacks will be described whereafter. Local Operation,Monitoring,Control and Setup by LCT will be described whereafter.

January 15, 2007

NEC Corporation 2007

2007-01-15

Outline of NEO IDU:


IDU Name Plate

IDU 1+0 Front Panel

IDU 1+1 Front Panel


January 15, 2007 NEC Corporation 2007 3

Outline of NEO ODU:

ODU
January 15, 2007 NEC Corporation 2007 4

2007-01-15

IDU Composition 1:

IDU Rack

January 15, 2007

NEC Corporation 2007

IDU Composition 2:
NO. 1 2 3 H2931 H2940 H2940 H3040 H2960 4 H2965 H3021 5 H2960 H2965 H2980 6 H3000 H3010 7 H2950 Unit/Module Name Rack Modem Modem DC-DC CONV STM-1 INTFC LAN/WS INTFC GbE INTFC STM-1 INTFC LAN/WS INTFC 16E1 INTFC 48E1 INTFC E3 INTFC CTRL () () () () ( ) () () () () () NEC Corporation 2007 6 H2930 MDP-150MB-1AA Expandable 1+0 System p y 1+1 System y Remarks Note: Usually provide () Optionally provide QPSK/16QAM/32QAM/128QAM -20 to -60/+2- to +60 VDC STM1-E/O-S-1.1/L-S-1.1 *3 SDH 2-Port-LAN SDH-GbE STM1-O-S-1.1/L-S-1.1 *3 for APS / WS-SC-LAN/WS/SC-LAN *3 PDH-16E1 e/w 2 Port LAN *3 PDH-48E1 PDH-E3 e/w 4/8E1,2 Port LAN *3
*2 *1

*1 Selectable in setting program *2 For expanding power supply range when the Pasolink+ ODU(EHG) is connected to the IDU NEO. *3 Selectable by changing the module type.

January 15, 2007

2007-01-15

ODU Composition:
Module Name 6GHz NWA-009024( ) 7GHz NWA-009026( ) 8GHz NWA-009028( ) 10GHz NWA-009030( ) 11GHz NWA-009032( ) 13GHz NWA-009034( ) TRP-()G-1B 15GHz NWA-009036( ) 18GHz NWA-009038( ) 23GHz NWA-009040( ) 26GHz NWA-009042( ) 28GHz NWA-009044( ) 32GHz NWA-009046( ) 38GHz NWA-009048( ) 52GHz NWA-009050( ) January 15, 2007 NEC Corporation 2007 1 RF CKT H2202( ) H2203( ) H2204( ) H2225( ) H2205( ) H2227( ) H2228( ) H2229( ) H2230( ) H2231( ) H2232( ) H2233( ) H2234( ) H0416( ) 7 2 IF CKT 3 PS

6-52GHz ODU

IDU Shelf:

G: Electrostact Discharge (ESD) Jack used to connect wrist strap band.

Caution: Persons for maintenance the equipment must take the necessary steps to avoid bit errors or cause damage to the modules due to electrostatic discharge. Wear a conductive wirst strap connected to the ground jack(G) on the front of the IDU to minimize static build-up during maintenance.

January 15, 2007

NEC Corporation 2007

2007-01-15

CTRL:

The CTRL generates various control signals based upon LCT setup data and gathered operating status in the IDU and from the ODU. The Th CTRL h SC, EOW, LAN NE EXT ALM,HK,Cluster ALM signals iinterface. has SC EOW LAN, NE, ALM HK Cl t i l t f

January 15, 2007

NEC Corporation 2007

CTRL: Function of Interface 1


Item/Function
AUX/ALM (D-Sub Female 44 Pins) / ( ) Eow Frequency Level Impedance ALM Output Input Bz 1,2 IN Call 1,2 OUT NE (RJ-45): Level NMS(RJ-45) Level January 15, 2007 NEC Corporation 2007

Description
Input/Output Signal p / p g 1 CH 0.3 to 3.4KHz (1020Hz(Test Tone)) -6dBm 600 ohms ALM 6 Outputs/6 HK Inputs/4 HK Control Outputs/ Cluster 4 Input&Outputs Relay contact Form-C Photocoupler Signalling control extension input g g p Signalling control extension output Network Element 10 Base-T PNMS 10 Base-T 10

2007-01-15

CTRL: Function of Interface 2


Item/Function
SC IN/OUT ( / (D-Sub Female 44 Pins) ) NE2 Level DSC (RS-232C) Bit rate Level DSC(V.11) Bit rate Level Impedance EOW LCT (USB)

Description
Input/Output Signal p / p g Network Element RS-485 2CH 9600 bps RS-232C 2CH 64Kbps V.11 100 ohms EOW headphone Serial interface USB-B type connector with PC

January 15, 2007

NEC Corporation 2007

11

CTRL: Function of Indicators & Switch


LED MAINT MEMORY IDU Switch CALL PROTECT
IDU Summary Alarm

Indication
Maintenance mode can be selected by LCT,PNMT and y , PNMS Memory Card (MMC) Status

Remarks
Actively blinks:In Progress of p g data download y g program Inactively blinks:Protect Mode for CTRL replacement into effect ON: Enable access to Memory Card OFF: Disable access to Memory Card Blinks: Accessing Memory Card Check ALM LEDs on each module to find the cause and /or connect LCT to check the performance condition. Blinks:CPU or peripheral event occurred

Operating
Transmits EOW calling signal to sound the buzzer in the opposite station Prevent service interruption when the CTRL module is replaced

Remarks

Accessing the Memory Card (MMC) is required to apply the function

January 15, 2007

NEC Corporation 2007

12

2007-01-15

CTRL: Pin Assignment 1


Terminal Pins
Pins 1 (+) and 16 (-) Pins 2 (+) and 17 (-) Pins 3 (+) and 18 (-) EOW Input 1 EOW Output 1 EOW Input 2 EOW Output 2 Ground Maintenance alarm output IDU CPU/PS1/PS2 alarm output ODU1/ODU2 alarm output
*2

Descrption

Pins
Pins 15 (+) and 14 (-) Pins 13 (+) and 12 (-) Pins 29 (+) and 28 (-) Pins 27 (+) and 26 (-) Pins 44 (+) and 43 (-) Pins 42 (+) and 41 (-) Pins 30 Pins 31 Pins 32 Pin 33

Descrption
HK1 alarm input*3 HK2 alarm input*3 HK3/Cluster4 alarm input*3 HK4/Cluster3 alarm input*3 HK5/Cluster2 alarm input*3 HK6/Cluster1 alarm input*3 Buzzer input 1 Call output 1 Buzzer input 2 Call output 2

ALM/AUX IN/OUT (D-Sub Female,44 Pins) Service Channel Data Input/Output

Pins 4 (+) and 19 (-) Pin 5 Pins 25(COM), 40(NC) and 11(NO)------RL1 *1 Pins 24 (COM),39(NC) and 10(NO)------RL2 *1 Pins 23(COM),38(NC) and 9(NO)-------RL3 Pins 22(COM),37(NC) and 8(NO)-------RL4 Pins 21(COM),36(NC) and 7(NO)-------RL5 7(NO) RL5 Pins 20(COM),35(NC) and 6(NO)-------RL6

ODU CUP1/ODU CUP2/Cable Open alarm output *2 IDU total alarm output *2 High BER1/High BER2 alarm output*2

*1 RL1 and RL2 are fixed *2 Items be assigned at the factory *3 Photocoupler Interface. January 15, 2007 NEC Corporation 2007 13

CTRL: Pin Assignment 2


Terminal Pins
Pins 1(+) and 2 (-) Pins 3 Pins 4 (+) and 5 (-) Pins 6 (+) and 7 (-) Pins 8 (+) and9 (-) NE2 TXD Ground V.11-1 data input V.11-1 data output V.11-2 data input V.11-2 data output RS-232C-1 data input RS-232C-2 data input NE2 RXD TERM Ground V.11-1 Clock input V.11-1 Clock ooutput

Descrption

Pins
Pins 23 (+) and 24 (-) Pins 25 (+) and 26 (-) Pins 27,28,29 Pins 30 (+) and 31 (-) Pins 32 Pins 33 (+) and 34 (-) Pins 35 (+) and 36 (-) Pins 37 (+) and 38(-) Pins 39 (+) and 40 (-) Pins 41 and 42 (G) () Pins 43 and 44 (G)

Descrption
V.11-2 Clock input V.11-2 Clock output Ground NE2 RXD Ground V.11-1 frame pulse input V.11-1 frame pulse output V.11-2 frame pulse input V.11-2 frame pulse output RS-232C-1 data output p RS-232C-2 data output

SC IN/OUT (D-Sub Female,44 Pins)

Pins 10 (+) and 11(-) Pins 12 and 13 (G) Pins 14 and 15 (G) Pins 16 Pins 17,18 , Pins 19 (+) and 20 (-) Pins 21 (+) and 22 (-)

January 15, 2007

NEC Corporation 2007

14

2007-01-15

CTRL: Pin Assignment 3


Terminal LCT (USB Connector type B) Local craft terminal data input/output NMS (RJ-45) PNMS data (10 Base-T) input/output NE (RJ-45) (RJ 45) NE data (10 Base-T) input/output
Pin 1 Pins 2(-) and 3 (+) Pin 4 Pins 1(+) and 2 (-) Pins 3 (+) and 6 (-) Pins 4, 5,7and 8 Pins 1 (+) and 2 (-) Pins 3 (+) and 6 (-) () Pins 4,5,7 and 8

Pins
Vbus D Ground NMS TXD NMS RXD Not Connected NMS TXD NMS RXD Not Connected

Descrption

January 15, 2007

NEC Corporation 2007

15

CTRL: EOW Wiring

January 15, 2007

NEC Corporation 2007

16

2007-01-15

MODEM:
Caution: 1.Dont apply to the equipment a voltage that varies sharply.The equipment may operate h l Th i t t wrongly. 2.Dont remove/connect the IF cable with the IDU power ON,turn the IDU power OFF before connecting/disconnecting the IF cable,or equipment may be damaged. 3.Dont insert/extract the MODEM with the power ON, turn the IDU power OFF and remove all cables connected to the MODEM before insert/extract the MODEM, or MODEM may be damaged. 4.The 4 top surface off IDU shelff above MODEM is f hot in operation.

Then MODEM provides the QPSK/16QAM/32QAM/128QAM Modulation/Demodulation. Following Main Functions:


Fowward Error Correction BER detection/indication/release for internal and external Reducing ODU output signal distrotion Equalization XPIC ODU Synthesizer synchronization control Interfered signal from opposite polarization cancellation (XPIC) IDU/ODU power supply System power on/off

January 15, 2007

NEC Corporation 2007

17

MODEM:Function of Interface
Item/Function
IF IN/OUT (TNC Female) TX Frequency RX Frequency Power Supply Impedance IF Cable Length G (Screw) SELV (Molex M5569-04A1,4 Pins) Input voltage XIF IN/XIF OUT O XIF IN XIF OUT Frequency Impedance XPIC CTRL (D-Sub 15 Pins,Serial Port) January 15, 2007 340MHz 140MHz -48V 50 ohms 5D-FB<150M, 8D-FB<300, 10D-FB<350M Ground terminal (5mm square cable is recommended) DC Input -48V DC (Negative), +(Positive,Ground) Only O used ffor XPIC system between two IDUs C IF signal of opposite polarization input (connect to XIF OUT of the other MODEM) IF signal of opposite polarization output (connect to XIF IN of the other MODEM) 140MHz 75 ohms Only used for XPIC system between two IDUs(connect to XPIC CTRL of theother MODEM) NEC Corporation 2007 18

Description

2007-01-15

MODEM: Function of Indicators


LED PWR Indication
The PWR switch of the MODEM is turned on Transmit RF power of the ODU descreased approx.-3dB Receiver input level of the ODU falls below squelch level APC loop of local oscillator in ODU is unlocked IF signal from the MODEM to ODU is lost Blinks when If cable is open circuit Connected ODU is not matched with inventory Blinks when IF cable is short circut Selected status of ODU TX Selected status of MODEM RX output signal p g XPIC function is OFF condition When TX mute control: LED OFF When RX SWO switched to opposite: LED off pp Only XPIC configuration Progagation condition deteriorated or XPIC is reset from LCT control

Remarks
DC Power is supplied to theo ODU also. pp

ODU

Check Metering using LCT for Local and/or opposite site

MD/CBL TX (only 1+1) RX (only 1+1) XPIC RESET

January 15, 2007

NEC Corporation 2007

19

MODEM: Function of Switch


Switch PWR Operating
IDU and ODU power On/Off switch

Remarks

January 15, 2007

NEC Corporation 2007

20

10

2007-01-15

MODEM: Pin Assignment


Terminal ( ) SELV (DC IN) (Molex M5569-04A1 Connector, 4 Pins) Only -48V (-40.5----57V) is available. IF IN/OUT Pins
Pins 1 and 3 Pins 2 and 4 TNC Jack (Female) Pins 1 (+) and 6 (-) Pins 2 (+) and 7 (-) Pin 3 Pins 4 (+) and 9 (-) Pins 5 (+) and 10 (-) Pins 8 (+) and 12 (-) Pin 11 Pins 13 (-) and 14 (+) Pin 15 Ground -48V IF signal IN/OUT and PS OUT to the ODU XPIC SV TXD XPIC SV RXD Ground XPIC SEL IN XPIC SEL OUT XPIC RESET IN Ground XPIC RESET OUT Ground

Descrption

XPIC CTRL (D-Sub Female,15 Pins) Used for interconnection between IDUs in XPIC configuration

January 15, 2007

NEC Corporation 2007

21

48E1 INTFC:
Caution: Do not insert/extract the 48E1 INTFC with the power ON,turn the IDU power OFF and Remove all cables connected to the 48E1 INTFC before insert/extract the 48E1 INTFC, or 48E1 INTFC may be damaged.

The 48E1 INTFC applies for up to 48E1 signals interface. The module performs following functions:
Bipolar-Unipolar/Unipolar to Bipolar conversion Stuffing/Destuffing Multiplex/Demultiplex the radio section frame Hitless Switching AIS D t ti /G Detection/Generation ti Near End/Far End loopback for Each EI CH 75 ohms/120 ohms selectable impedance

January 15, 2007

NEC Corporation 2007

22

11

2007-01-15

48E1 INTFC: Function of Interface


Item/Function
2M IN/OUT-A/-B/-C (MDR Connector) / / / ( ) Input/Output Signal Bit Rate Code Impedance

Description
16E1 interface in each 3 connectors Up to 48E1 signals 2.048 Mbps HDB3 75 ohm unbalanced or 120 ohms balanced

January 15, 2007

NEC Corporation 2007

23

48E1 INTFC: Function of Indicators


LED Indication
LOS ffrom DTE IS detected OS S Check DTE and Wiring C Perform Far End loopback test Signal is applied to unused channel Change LCT Setting or Other ( ) INTFC module Loss of output signal to DTE is detected Error of channel usage Mounting module is not matched with inventory

Remarks

ALM

January 15, 2007

NEC Corporation 2007

24

12

2007-01-15

48E1 INTFC: Pin Assignment


Terminal Pins
Pins 1,34,35,and 68 Pins 33(+) and 67(-) Pins 32(+) and 66(-) Pins 31(+) and 65(-) Ground CH1/CH17/CH33 data output CH1/CH17/CH33 data input CH2/CH18/CH34 data output CH2/CH18/CH34 data input CH3/CH19/CH35 data output CH3/CH19/CH35 data input CH4/CH20/CH36 data output CH4/CH20/CH36 data input CH5/CH21/CH37 data output CH5/CH21/CH37 d input data i CH6/CH22/CH38 data output CH6/CH22/CH38 data input CH7/CH23/CH39 data output CH7/CH23/CH39 data input CH8/CH24/CH40 data output CH8/CH24/CH40 data input

Descrption

Pins
Pins 17(+) and 51(-) Pins 16(+) and 50(-) Pins 15(+) and 49(-) Pins 14(+) and 48(-) Pins 13(+) and 47(-) Pins 12(+) and 46(-) Pins 11(+) and 45(-) Pins 10(+) and 44(-) Pins 9(+) and 43(-) Pins 8(+) and 42(-) Pins Pi 7(+) and 41(-) d 41( ) Pins 6(+) and 40(-) Pins 5(+) and 39(-) Pins 4(+) and 38(-) Pins 3(+) and 37(-) Pins 2(+) and 36(-)

Descrption
Ch9/CH25/CH41 data output CH9/CH25/CH41 data input CH10/CH26/CH42 data output CH10/CH26/CH42 data input CH11/CH27/CH43 data output CH11/CH27/CH43 data input CH12/CH28/CH44 data output CH12/CH28/CH44 data input CH13/CH29/CH45 data output CH13/CH29/CH45 data input CH14/CH30/CH46 d output data CH14/CH30/CH46 data input CH15/CH31/CH47 data output CH15/CH31/CH47 data input CH16/CH32/CH48 data output CH16/CH32/CH48 data input

48E1 INTFC 2M IN/OUT-A (CH1 to CH16) 2M IN/OUT-B (CH17 to CH32) / 2M IN/OUT-C (CH33 to CH48) (MDR Connector,68Pins)

Pins 30(+) and 64(-) Pins 29(+) and 63(-) Pins 28(+) and 62(-) Pins 27(+) and 61(-) Pins 26(+) and 60(-) Pins 25(+) and 59(-) Pins Pi 24(+) and 58(-) d 58( ) Pins 23(+) and 57(-) Pins 22(+) and 56(-) Pins 21(+) and 55(-) Pins 20(+) and 54(-) Pins 19(+) and 53(-) Pins 18(+) and 52(-)

January 15, 2007

NEC Corporation 2007

25

48E1 INTFC: I/O Board (Optional)

When 37 pins interface is required to the 2M IN/OUT INTFC instead of MDR interface.

Note: One Unit space is necessary to install I/O BOARD above IDU

January 15, 2007

NEC Corporation 2007

26

13

2007-01-15

48E1 INTFC: Pin Assignment for I/O Board


Terminal Pins
Pins 5,10,15,24 and 33 Pins 1(+) and 2(-) Pins 3(+) and 4(-) Pins 6(+) and 7(-) Ground CH8/CH16/CH24/CH32/CH40/CH48 data input CH7/CH15/CH23/CH31/CH39/CH47 data input CH6/CH14/CH22/CH30/CH38/CH46 data input CH5/CH13/CH21/CH29/CH37/CH45 data input CH4/CH12/CH20/CH28/CH36/CH44 data input CH3/CH11/CH19/CH27/CH35/CH43 data input CH2/CH10/CH18/CH26/CH34/CH42 data input CH1/CH9/CH17/CH25/CH33/CH418 data input CH8/CH16/CH24/CH32/CH40/CH48 data output CH7/CH15/CH23/CH31/CH39/CH47 data output CH6/CH14/CH22/CH30/CH38/CH46 data output CH5/CH13/CH21/CH29/CH37/CH45 data output CH4/CH12/CH20/CH28/CH36/CH44 data output CH3/CH11/CH19/CH27/CH35/CH43 data output CH2/CH10/CH18/CH26/CH34/CH42 data output CH1/CH9/CH17/CH25/CH33/CH418 data output

Descrption

8E1 INTFC 2M IN/OUT (CH1 to CH8) (CH9 to CH16) (CH17 to CH24) (CH25 to CH32) (CH33 to CH40) (CH41 to CH48) (D-Sub Connector,37Pins)

Pins 8(+) and 9(-) Pins 11(+) and 12(-) Pins 13(+) and 14(-) Pins 16(+) and 17(-) Pins 18(+) and 19(-) Pins 20(+) and 21(-) Pins 22(+) and 23(-) Pins 25(+) and 26(-) Pins 27(+) and 28(-) Pins 29(+) and 30(-) Pins 31(+) and 32(-) Pins 34(+) and 35(-) Pins 36(+) and 37(-)

January 15, 2007

NEC Corporation 2007

27

16E1 INTFC:
Caution: Do not insert/extract the 16E1 INTFC with the power ON,turn the IDU power OFF and Remove all cables connected to the 16E1 INTFC before insert/extract the 16E1 INTFC, or 16E1 INTFC may be damaged.

The 16E1 INTFC applies for up to 16E1 signals interface. 2 PORT LAN interface provedes optionally to transmit up to 80Mbps The module performs following functions:
Bipolar-Unipolar/Unipolar to Bipolar conversion Stuffing/Destuffing Multiplex/Demultiplex the radio section frame Hitless Switching AIS Detection/Generation Near End/Far End loopback for Each EI CH 75 ohms/120 ohms selectable impedance

January 15, 2007

NEC Corporation 2007

28

14

2007-01-15

16E1 INTFC: I/O Board (Optional)

When the BNC 16E1 Interface is required to the 2M IN/OUT INTFC intead of D-Sub 37 pins

Note:One Unit space is necessary to install I/O BOARD above or below IDU and 2 D-Sub/D-sub cable also.

January 15, 2007

NEC Corporation 2007

29

16E1 INTFC: Function of Interface


Item/Function
2M IN/OUT-A/-B (D-Sub Connector) Input/Output Signal Bit Rate Code Impedance PORT1/PORT2 (RJ-45) Optional Input/Output Signal Flow Control Forwarding mode

Description
8E1 interface in each 2 connectors Up to 16E1 signals without LAN 2.048 Mbps HDB3 75 ohm unbalanced or 120 ohms balanced LAN Interface port 1 and port 2 separated. 8 to 80Mbps shared when 16E1 to 0E1 are used 10/100Base-T(X) Auto-sensing or fixed Full duplex or Half duplex Store-and Forwarding

January 15, 2007

NEC Corporation 2007

30

15

2007-01-15

16E1 INTFC: Function of Indicators


LED Indication
LOS from DTE is Detected Loss of output signal to DTE is detected Check DTE and wiring Perform Far End loopback test Signal is applied to unused channel Change LCT setting or other () INTFC module Check LAN cable connection

Remarks

ALM

Error of channel usage Mounting module is not matched with inventory LAN link failure occurs. (e/w LAN PORT)

100M LINK COLLISION/DUPLEX

LAN signal is in 100Base-TX mode LAN and Associated equipment are linked and flashing under dA i d i li k d d fl hi d the exchanging the packet Input/Output LAN signal is in Full Duplex mode.Flashing when a collision condition occurs

January 15, 2007

NEC Corporation 2007

31

16E1 INTFC: Pin Assignment 1


Terminal Pins
Pins 5,10,15,24 and 33 Pins 1(+) and 2(-) Pins 3(+) and 4(-) Pins 6(+) and 7(-) Pins 8(+) and 9(-) Ground CH8/CH16 data input CH7/CH15 data input CH6/CH14 data input CH5/CH13 data input CH4/CH12 data input CH3/CH11 data input CH2/CH10 data input CH1/CH9 data input CH8/CH16 data output CH7/CH15 data output CH6/CH14 data output CH5/CH13 data output CH4/CH12 data output CH3/CH11 data output CH2/CH10 data output CH1/CH9 data output

Descrption

16E1 INTFC 2M IN/OUT (CH1 to CH8) (CH9 to CH16) (D Sub Connector,37Pins) (D-Sub Connector 37Pins) (I/O BOARD IDU INTFC)

Pins 11(+) and 12(-) Pins 13(+) and 14(-) Pins 16(+) and 17(-) Pins 18(+) and 19(-) Pins 20(+) and 21(-) Pins 22(+) and 23(-) Pins 25(+) and 26(-) Pins 27(+) and 28(-) Pins 29(+) and 30(-) Pins 31(+) and 32(-) Pins 34(+) and 35(-) Pins 36(+) and 37(-)

January 15, 2007

NEC Corporation 2007

32

16

2007-01-15

16E1 INTFC: Pin Assignment 2


Terminal
Pin1 Pin2

Pins
LAN TD+/LAN RD+ LAN TD-/LAN RDLAN RD+/LAN TD+ Not connected LAN RD-/LAN TDNot connected

Descrption

LAN PORT1/PORT2 (RJ-45, 8 Pins) Optional

Pin3 Pins 4 and 5 Pin 6 Pin 7 and 8

Note: Dont connect any cable to the Not Connected pins

January 15, 2007

NEC Corporation 2007

33

STM-1 INTFC:
Two Types of Interface are available:
Electrical Optical

The Module performs following functions:


CMI to NRZ conversion Optical to Electrical conversion (For Optical INTFC only) RSOH termination Stuffing control Hitless switching (for 1+1 configuration) Performance monitoring Automatic Laser Shut Down (ALS) Near End/Far End loopback

STM-1 (E) INTFC

Caution:
Dont insert/extract the STM-1 INTFC with power ON,turn OFF the PWR switch on the MODEM and remove all cables connected to STM-1 INTFC before insert/extract the STM-1 INTFC, or STM-1 INTFC may be damaged.

STM-1 (O) INTFC


January 15, 2007 NEC Corporation 2007

34

17

2007-01-15

STM-1 INTFC: Function of Interface


Item/Function
STM 1 STM-1 IN/OUT (IEC 169-29) 169 29) Type Bit Rate Level Code Impedance STM-1 IN/OUT (LC) Type Bit Rate Level Code Wavelength
January 15, 2007

Description
Electrical STM-1 Input/Output STM 1 G.703 155.520 Mbps 1 Vp-p (nominal) CMI 75 ohms unbalanced Optical STM-1 Input/Output G.957 155.520 Mbps L-1.1: 0 to -8 dBm(TX)/-10 to -34dBm (RX) S-1.1: -8 to -15dBM(TX)/-8 to -28dBm (RX) NRZ 1310nm
NEC Corporation 2007 35

STM-1 INTFC: Function of Indicators


LED Indication LOS off STM 1 ffrom MUX iis detected STM-1 dt td Frame synchroniztion of input STM-1 signal from MUX is los(Electrical INTFC) BER is worse than preset valure (10-3 to 10-5,Selectable) ALM BER is worse than preset value (10-5 to 10-9, Selectable) Frame synchronization of input STM-1 signal from radio is lost Mounting module is not matched with inventory Online status of Working/Standby in APS:ON ONLINE Offline status of Working/Standby in APS: OFF Online status of Working w/o APS: ON Remarks Check Ch k MUX and wiring d ii Check MUX and wiring Check RSL, Interference and TX power at opposite site when BER ALM occurs Check STM-1 transmission at the opposite site,ODU or MODEM in local Change LCT setting or other () INTFC moduel

January 15, 2007

NEC Corporation 2007

36

18

2007-01-15

E3 INTFC:

E3 INTFC applies for up to 2 E3(34.368Mbps)signal,4 or 8 WS(2.048Mbps) signal and 2 prot LAN(10/100Base-T) signal. 2 Port LAN Interface provide optionally to transmit upt to 16Mbps LAN signal using WS(E1)/SC signal Band The module performs following functions:
Bipolar-Unipolar/Unipolar-Bipolar conversion Stuffing/Destuffing Multiplex/Demultiplex the radio section frame Hitless Switching AIS Detection/Generation 75ohms unbalance/120ohms balance interface for WS can be selectable.

Caution:
Dont insert/extract the E3 INTFC with power ON,turn OFF the PWR switch on the MODEM and remove all cables connected to E3 INTFC before insert/extract the E3 INTFC, or E3 INTFC may be damaged. January 15, 2007 NEC Corporation 2007 37

E3 INTFC: Function of Interface


Item/Function
E3 CH1/CH2 IN/OUT (IEC 169-29) 169 29) Bit Rate Code Impedance LAN PORT1/PORT2 (RJ-45) Optional 2E3 interface in each 2 ports 34.268Mbps HDB3 75 ohms unbalanced LAN interface port 1 and 2 shared. Selectable 2 to 16 Mbps(for 2 E3) shared according to WS (1E1 to 8E1) CHs are assigned for LAN. Selectable 64/128/256kbps shared according to SC (SC1 to SC4) CHs are assigned for LAN 10/100Base-T(X) Auto-Sensing or fixed Full duplex or Half duplex Store-and Forwarding

Description

Input/Output Signal Flow control Forwarding mode

January 15, 2007

NEC Corporation 2007

38

19

2007-01-15

E3 INTFC: Function of Indicators


LED LOS from DTE is detected ALM Loss of output signal to DTE is detected Mounting module is not matched with inventory LAN link faulure occurs,(e/w LAN PORT) 100M LINK COLLISION/ DUPLEX Lan signal is in 100Base-TX mode LAN and associated equipment are linked and flashing under the exchanging the packet Input/Output LAN signal is in Full Duplex mode. Flashing when a collision condition occurs. Indication Remarks Check DTE and wiring Perform Far End loopback test Change LCT Setting or other ()INTFC module Check LAN Cable connection

January 15, 2007

NEC Corporation 2007

39

E3 INTFC: Pin Assignment 1


Terminal
Pins 5,10,15,24 and 33 Pins 1(+) and 2(-) Pins 3(+) and 4(-) Pins 6(+) and 7(-) Pins 8(+) and 9(-) Pins 11(+) and 12(-)

Pins
Ground CH8 data input CH7 data input CH6 data input CH5 data input CH4 data input CH3 data input CH2 data input CH1 data input CH8 data output CH7 data output CH6 data output CH5 data output CH4 data output CH3 data output CH2 data output CH1 data output

Descrption

WS INTFC WS IN/OUT (CH1 to CH8) (D Sub (D-Sub Connector,37Pins)

Pins 13(+) and 14(-) Pins 16(+) and 17(-) Pins 18(+) and 19(-) Pins 20(+) and 21(-) Pins 22(+) and 23(-) Pins 25(+) and 26(-) Pins 27(+) and 28(-) Pins 29(+) and 30(-) Pins 31(+) and 32(-) Pins 34(+) and 35(-) Pins 36(+) and 37(-)

January 15, 2007

NEC Corporation 2007

40

20

2007-01-15

E3 INTFC: Pin Assignment 2


Terminal
Pin1 Pin2

Pins
LAN TD+/LAN RD+ LAN TD-/LAN RDLAN RD+/LAN TD+ Not connected LAN RD-/LAN TDNot connected

Descrption

LAN PORT1/PORT2 (RJ-45,8 Pins)

Pin3 Pins 4 and 5 Pin 6 Pin 7 and 8

Note: Dont connect any cable to the Not Connected pins

January 15, 2007

NEC Corporation 2007

41

DC-DC CONV (Optional):

This module converts 20 to 60 V or -20 to -60 V DC input to -43V stable DC voltage. This module applies when the Pasolink+ ODU is connected to the IDU NEO.

Caution: 1.Dont apply to the equipment a voltage that varies sharply.The equipment may operate wrongly. 2.Dont remove/connect the power supply cable with the PWR switch ON,Turn the PWR switch OFF before connecting/disconecting the power supply cable IN or OUT, or module may be damaged.

January 15, 2007

NEC Corporation 2007

42

21

2007-01-15

DC-DC CONV: Function of Interface


Item/Function
SELV (Molex M 5569 04A1 4Pins) 5569-04A1,4Pins) Input Voltage: -43V OUT (Molex M 5569-02A1,2 Pins) Output G (Screw) ALM DC IN -20 to -60V/+20 to +60 V DC DC OUT (Connect to the SELVconnector of the MODEM module) -43V/1.6A Ground terminal, 5mm square cable is recommended. Power supply ALM signal output

Description

January 15, 2007

NEC Corporation 2007

43

DC-DC CONV: Function of Indicators and Switches


LED PWR Indication The PWR switch of the DC-DC CONV is turned on DC DC Remarks

Switch
PWR

Operating
IDU and ODU Power on/off switch

Remarks

January 15, 2007

NEC Corporation 2007

44

22

2007-01-15

DC-CD CONV: Pin Assignment


Terminal SELV (DC IN) (Molex M5569-04A1 Connector, 4 Pins) -43V OUT (DC OUT) (Molex M5569-02A1 Connector, 2Pins) Pins
Pins 1 and 3 Pins 2 and 4 Pin 1 Pin 2 Pins 6 OV/(or +20 to +60V) -20 to -60V/(OR OV) Ground -43 V COM NC NO Ground No connected

Descrption

ALM (D-Sub Female,9 Pins)

Pin 1 Pin 2 Pin 9 Pins 3,4,5,7,8

January 15, 2007

NEC Corporation 2007

45

ODU:

ODU Front View

ODU Rear View of Antenna Direct Mounting Type

ODU Rear View of Coaxial Cable Type

January 15, 2007

NEC Corporation 2007

46

23

2007-01-15

ODU: Function of Interface


Item/Function
IFL (N Female) TX Frequency RX Frequency Power Supply Impedance IF Cable Lenght FG(Screw) 340MHz 140MHz -48V 50 ohms 5D-FB< 150M,8D-FB<300,10D-FB<350M Frame ground. RF Signal Interface RF IN/OUT N Female connector for the 6/7/8GHz ODU with Coxial cable connection NEC Proprietary flange for the 10 to 52GHz ODU with antenna mounting 6GHz PDR70,7/8GHz---PDR 84, 10/11GHz---PDR100, 13GHz---PBR 120 15GHz---PBR140, 18/23GHz---PBR220,26GHz---PBR260, 28/32/38GHz: PBR320 RX LEV MON
January 15, 2007

Description

Monitoring RX LEV in AGC Voltage using the digital voltmeter or PASOLINK MONITOR.
NEC Corporation 2007 47