You are on page 1of 101

1

Purpose
(1) To digitize and plot the pump performance curves and to obtain the equation-fit coefficients
(2) To avoid data duplication and to maintain one data source for each pump

Importance of this Template


Curve coefficients calculated in this template will be used when required in competitive analysis
Note: The Template for AP input of data from Test-Lab Sheets is similar but it differs in NPSH and Lift Test Head Calcu

Pump Performance Data that may need to be entered by this Template


R&D, Test, Published, H2Optimize, CFD-final. Use this template to obtain the
curve and the eq. fit coefficients used in the analysis of pump performance

File Name Convention


<[Competitor]-Pump-name> Curve Data

5
A

How to use this template


Tab [ GrabIt!] :
Follow the instructions in the tab for pick-up error evaluation and pick-up points selection

A
5.1

Tab [ Input] :
Enter new data as required. All grey cells are required inputs. NPSH data is an optional input and may be added on th
of columns on the input tab.

5.2

Enter the performance data in the new block under following heading
Data Point

GPM

TDH

BHP

Efficiency

RPM

Data point restriction (Max 10 point)


Data Point

GPM

NPSH

RPM

Data point restriction (Max 6 point)


Data Point

GPM

TDH

RPM

(For lift data under grey highlighted portion)

Data point restriction (Max 6 point)


Important Note:
1
2
3
500
4
1000
5
1250
6
1500
7
1750
8
2000
9
2250
10
2500

B
5.3

NPSH and Lift test Data (if plotted) must be entered with minimum 4 points
The shut-off capacity (zero capacity) is entered as a small positive number (1.e
A minimum of (6) data points are required for TDH or BHP curves.

All data must fill-in the last rows designated for data input - the last row must co
In other words if only 8 points are entered in 10-points field for Head, BHP, or E
the first point is entered in the third row.
Similarly for NPSH and Lift Head Data which are entered in a table of 6 (instead

Tab [Curves] :
This tab needs an updated only if new input blocks were copied&pasted in the Input tab.

If a new block must be added to this tab to accommodate new blocks in the Input tab then copy&paste an existing block
This will require update only on the links of the series in the newly created graphs to point to the corresponding new ser
No other update is necessary.
Note that LINEST function for obtaining the coefficients of the curves does not require any update as it is span over the
(for Head, BHP and Eff.) and over the last 4 points for (NPSH and Lift test) which are the minimum required number of
5.4

Data Checking in Tab [Input]


Check the data in Tab [Input] if it is entered accurately

5.5

Data Checking in Tab [Curves]


Check the % errors between the input data point and those obtained by the eq. fit.
If the max(error) is above 1% a warning will be displayed. In that case, review your digitized data for accuracy.
Correct the input data if necessary.

5.6

Write the owner name (your name if you have entered or corrected the data) in each block of the data.

Units of Data in Tab [ input]


Flow
[GPM]
Head
[Feet]
Power
[hp]
Efficiency
[100 x %]
NPSH
[Feet]
Lift
[Feet] ( Enter the last 6 value with out velocity correction)

Other Important Notes related to this template


Do not change any formula, layout or format of the blocks without notifying Boyko Tchavdarov (AP).
The Tabs are locked and should remain locked unless the above mentioned updates require to unlock them.
Most cells in the Curves tab are locked and should not require modification.

Using the pump curve data in other Spreadsheets


Pump curve data from this spreadsheet can be used in another spreadsheet. This must be done by copy& paste the cu
obtained for the right trim and speed along with the maximum error and the capacity at which this error occur. If the spe
fit the curve below the capacity at which the LINEST function has been applied, than a copy of this spreadsheet must be
changes must be approved by Boyko Tchavdarov (AP) before using the new template designate for low capacity sectio

To copy coefficients to a pump's CAP Tabular Data file, refer to columns AK:AZ. Coefficients in these columns are pro
copied and pasted in the CAP Tabular Data file.

it coefficients

etitive analysis
ers in NPSH and Lift Test Head Calculation

up points selection

optional input and may be added on the right-hand grouping

hlighted portion)

be entered with minimum 4 points


ntered as a small positive number (1.e-6) but not as zero,.
d for TDH or BHP curves.

ed for data input - the last row must contain data.


d in 10-points field for Head, BHP, or Eff.,

hich are entered in a table of 6 (instead of 10) rows

tab then copy&paste an existing block at the end.


s to point to the corresponding new series.

quire any update as it is span over the last 6 points


are the minimum required number of points.

y the eq. fit.


r digitized data for accuracy.

e data) in each block of the data.

o Tchavdarov (AP).
ates require to unlock them.

s must be done by copy& paste the curve coefficients


city at which this error occur. If the specific of work require to
han a copy of this spreadsheet must be created and the any
plate designate for low capacity section of the curve.
Coefficients in these columns are properly formatted to be

Instructions; Copy&past the Test Report as shown below or enter data from curves .
Print/Enter data at nominal RPM and Head in feet !!
Leave four empty lines on the top of each record:
To insert new data insert 30 empty rows in Log and Test tabs . Then copy&paste tables and graphs in L
Test No
THE DURIRON COMPANY -

Owner
Date:

7/2/2010

Serial No:

Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq inch

Descript.
Customer
Pump Size
Disch/Suc. ID

2k3x2-8
DURO MARK III
3.000
2.000

Impeller Dia.

8.188

Pump Model

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

Filing Tip Work

OK!

Stages

Data Point

GPM

0.00
20.00
50.00
100.00
120.00
140.00
150.00
180.00

1
2
3
4
5
6
7

TDH (feet)

31.00
31.00
30.90
27.80
25.13
22.00
20.00
13.00

BHP

0.52
0.62
0.78
1.05
1.14
1.23
1.27
1.41

( 100 x % )
Efficiency
#DIV/0!
#DIV/0!
0.00
25.25
50.08
66.86
67.07
63.23
59.70
41.91

OK!
OK!
OK!

Equation Fit Coefficients

RPM

1150
1150
1150
1150
1150
1150
1150
1150
1150
1150

BHP

9.317E-08

-3.741E-05

9.367E-03

TDH

-4.700E-07

-7.780E-04

6.190E-02

Eff.

-6.325E-06

-2.886E-03

8.786E-01

x1=

-4.156E+02

BEP

RPM
1150

x2=

GPM

TDH (feet)

111.4

26.4

OK!
OK!

Test No

Owner
Date:

THE DURIRON COMPANY -

7/2/2010

Serial No:

Descript.

Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq inch

Customer
Pump Size
Disch/Suc. ID

2k3x2-8
DURO MARK III
3.000
2.000

Impeller Dia.

8.000

Pump Model

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

Filing Tip Work


Stages

Data Point

OK!
1

GPM

TDH (feet)

BHP

( 100 x % )
Efficiency
#DIV/0!
#DIV/0!

OK!
OK!
OK!

Equation Fit Coefficients

RPM

1150
1150

BHP

-4.185E-08

8.012E-06

4.360E-03

TDH

-3.183E-06

3.582E-05

-1.933E-02

0.00
20.00
50.00
70.00
100.00
120.00
150.00
172.00

1
2
3
4
5
6
7
8

29.00
29.00
28.99
27.86
25.50
23.00
17.28
11.80

0.48
0.58
0.73
0.82
0.98
1.06
1.19
1.27

0.00
25.25
50.14
60.06
66.00
65.80
55.15
40.36

1150
1150
1150
1150
1150
1150
1150
1150

Eff.

-5.896E-06

-3.731E-03

x1=

-5.277E+02

RPM
1150

BEP

9.872E-01

x2=

GPM

TDH (feet)

105.8

24.8

OK!
OK!

Test No
THE DURIRON COMPANY -

Owner
Date:

7/2/2010

Serial No:

Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq inch

Descript.
Customer
Pump Size
Disch/Suc. ID

2k3x2-8
DURO MARK III
3.000
2.000

Impeller Dia.

7.500

Pump Model

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

Filing Tip Work

OK!

Stages

OK!
OK!
OK!

Data Point
1
2
3
4
5
6
7
8
9
10

GPM

TDH (feet)

0.00
20.00
40.00
60.00
80.00
100.00
120.00
130.00
140.00
152.00

24.00
24.00
24.00
23.70
22.00
20.20
17.80
15.70
13.32
9.90

BHP

0.40
0.47
0.56
0.64
0.74
0.82
0.88
0.91
0.94
0.95

( 100 x % )
Efficiency
0.00
25.79
43.29
56.11
60.07
62.21
60.98
56.64
50.09
40.00

Equation Fit Coefficients

RPM

1150
1150
1150
1150
1150
1150
1150
1150
1150
1150

BHP

-1.811E-07

4.168E-05

8.092E-04

TDH

-1.271E-05

2.610E-03

-2.441E-01

Eff.

-6.135E-05

1.250E-02

-6.247E-01

x1=

3.300E+01

BEP

RPM
1150

x2=

GPM

TDH (feet)

102.9

20.0

OK!
OK!

Test No

Owner
Date:

THE DURIRON COMPANY -

7/2/2010

Serial No:

Descript.

Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq inch

Customer
Pump Size
Pump Model
Disch/Suc. ID

2k3x2-8
DURO MARK III
3.000
2.000

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

Impeller Dia.

7.000

Filing Tip Work

OK!

Stages

OK!
OK!
OK!

Data Point
1
2
3
4
5
6
7
8
9
10

GPM

TDH (feet)

0.0001
10.00
20.00
40.00
60.00
80.00
100.00
120.00
130.00
140.00

20.00
20.50
21.00
20.00
19.70
17.70
15.28
11.84
10.00
8.00

BHP

0.35
0.38
0.40
0.48
0.55
0.60
0.65
0.69
0.69
0.70

( 100 x % )
Efficiency
0.00
13.62
26.52
42.09
54.27
59.60
59.21
51.89
47.58
40.40

Equation Fit Coefficients

RPM

1150
1150
1150
1150
1150
1150
1150
1150
1150
1150

BHP

-2.450E-07

5.626E-05

TDH

5.024E-07

-9.918E-04

3.616E-02

Eff.

9.057E-06

-9.940E-03

1.530E+00

x1=

6.442E+02

RPM
1150

BEP

-1.661E-03

x2=

GPM

TDH (feet)

87.4

16.9

OK!
OK!

Test No
THE DURIRON COMPANY -

Owner
Date:

7/2/2010

Serial No:

Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq inch

Descript.
Customer
Pump Size
Disch/Suc. ID

2k3x2-8
DURO MARK III
3.000
2.000

Impeller Dia.

6.500

Pump Model

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

Filing Tip Work

OK!

Stages

OK!
OK!
OK!

Data Point
GPM TDH (feet)
0.00001
17.6
1
20.00
17.50
2
30.00
17.40
3
40.00
17.10
4
60.00
16.00
5
80.00
14.00
6
100.00
11.56
7
110.00
10.00
8
120.00
7.69
9

125.00

10

6.50

Test No

Owner

THE DURIRON COMPANY -

( 100 x % )
BHP Efficiency
0.32
0.00
24.55
0.36
34.69
0.38
43.18
0.40
56.38
0.43
57.72
0.49
55.39
0.527
50.88
0.55
41.82
0.56
36.64
0.56

Equation Fit Coefficients

RPM

1150
1150
1150
1150
1150
1150
1150
1150
1150
1150

BHP

8.572E-08

-4.322E-05

7.717E-03

TDH

-2.163E-05

4.702E-03

-4.383E-01

Eff.

-1.482E-04

3.091E-02 -2.065E+00

x1=

BEP
OK!
OK!

RPM
1150

5.575E+01

x2=

GPM

TDH (feet)

83.3

13.7

Date:

7/2/2010

Serial No:

Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq inch

Descript.
Customer
Pump Size
Disch/Suc. ID

2k3x2-8
DURO MARK III
3.000
2.000

Impeller Dia.

6.000

Pump Model

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

Filing Tip Work

OK!

Stages

OK!
OK!
OK!

Data Point
GPM TDH (feet)
0.00001
14.8
1
10.00
14.80
2
20.00
14.80
3
30.00
14.60
4
40.00
14.00
5
50.00
13.99
6
60.00
13.50
7
80.00
11.02
8
100.00
7.70
9

112.00

10

5.70

( 100 x % )
BHP Efficiency
0.26
1.437E-05

0.27
0.30
0.31
0.33
0.35
0.380
0.40
0.42
0.44

13.84
24.92
35.68
42.85
49.77
53.83
55.95
46.74
36.64

Equation Fit Coefficients

RPM

1150
1150
1150
1150
1150
1150
1150
1150
1150
1150

BHP

5.767E-07

-1.396E-04

TDH

2.126E-05

-6.218E-03

4.342E-01

Eff.

-1.289E-05

-9.759E-03

1.636E+00

x1=

-5.781E+02

RPM
1150

BEP

1.202E-02

x2=

GPM

TDH (feet)

73.2

12.0

OK!
OK!

Test No

Owner
Date:

THE DURIRON COMPANY -

7/2/2010

Serial No:

Descript.

Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq inch

Customer
Pump Size
Disch/Suc. ID

2k3x2-8
DURO MARK III
3.000
2.000

Impeller Dia.

5.500

Pump Model

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

Filing Tip Work

OK!

Stages

OK!
OK!
OK!

Data Point
GPM TDH (feet)
0.00001
11.8
1
20.00
11.90
2
30.00
11.80
3
40.00
11.20
4
50.00
10.90
5
60.00
9.95
6
70.00
8.96
7
80.00
7.68
8

( 100 x % )
BHP Efficiency
0.22
1.354E-05

0.25
0.26
0.27
0.28
0.29
0.30
0.31

24.04
34.38
41.90
50.05
52.71
52.27
50.05

Equation Fit Coefficients

RPM

1150
1150
1150
1150
1150
1150
1150
1150

BHP

-3.796E-07

7.060E-05

-3.037E-03

TDH

-1.537E-05

2.030E-03

-1.735E-01

Eff.

-1.141E-04

8.439E-03

3.593E-01

x1=

-1.606E+01

BEP

RPM
1150

x2=

GPM

TDH (feet)

65.4

9.4

90.00
100.00

9
10

5.99
4.00

0.32
0.32

42.54
31.57

1150 OK!
1150 OK!

Test No
THE DURIRON COMPANY -

Owner
Date:

7/2/2010

Serial No:

Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq inch

Descript.
Customer
Pump Size
Disch/Suc. ID

2k3x2-8
DURO MARK III
3.000
2.000

Impeller Dia.

5.000

Pump Model

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

Filing Tip Work

OK!

Stages

OK!
OK!
OK!

Data Point
GPM TDH (feet)
0.00001
8.9
1
10.00
8.90
2
20.00
8.80
3
30.00
8.40
4
40.00
8.00
5
50.00
7.86
6
60.00
7.01
7
70.00
5.82
8
80.00
4.49
9

92.00

10

3.00

( 100 x % )
BHP Efficiency
0.16
1.405E-05

0.17
0.18
0.19
0.19
0.21
0.222
0.22
0.23
0.27

13.22
24.69
33.49
42.09
46.46
47.89
46.35
39.93
25.81

Equation Fit Coefficients

RPM

1150
BHP
1150
TDH
1150
Eff.
1150
1150
1150
1150
1150
BEP
1150 OK!
1150 OK!

2.279E-06

-4.363E-04

2.777E-02

4.069E-05

-9.289E-03

5.707E-01

-1.363E-04

7.098E-03

6.232E-01

x1=

-2.537E+01

RPM
1150

x2=

GPM

TDH (feet)

60.1

7.0

Test No

Owner
Date:

THE DURIRON COMPANY -

7/1/2010

Serial No:

Descript.

Semi open,STD-A05,Max sphere 13/32,eye area 3.5sq inch

Customer
Pump Size
Pump Model
Disch/Suc. ID

2k3x2-8
DURO MARK III
2.000
1.000

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

Impeller Dia.
Filing Tip Work

Error: Minimum 6 Test Points are required !

Stages

Data Point

GPM TDH (feet)

( 100 x % )
BHP Efficiency

#VALUE!
#VALUE!
#VALUE!

RPM

Equation Fit Coefficients

#DIV/0!

BHP

#VALUE!

#VALUE!

#VALUE!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

TDH

#VALUE!

#VALUE!

#VALUE!

Eff.

#VALUE!

#VALUE!

#VALUE!

x1=

BEP

RPM
0

#VALUE!

GPM

x2=

TDH (feet)

#VALUE! #VALUE!

#VALUE!
#VALUE!

10

Test No

Owner
Date:

THE DURIRON COMPANY -

7/1/2010

Serial No:

Descript.

Semi open,STD-A05,Max sphere 13/32,eye area 3.5sq inch

Customer
Pump Size
Pump Model
Disch/Suc. ID

2k2*1-10A
DURO MARK III
2.000
1.000

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

Impeller Dia.
Filing Tip Work

Error: Minimum 6 Test Points are required !

Stages

Data Point

GPM TDH (feet)

( 100 x % )
BHP Efficiency
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#VALUE!
#VALUE!
#VALUE!

Equation Fit Coefficients

RPM

3500
BHP
3500
TDH
3500
Eff.
3500
3500
3500
3500
3500
BEP
3500 #VALUE!
3500 #VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

x1=

RPM
3500

#VALUE!

GPM

x2=

TDH (feet)

#VALUE! #VALUE!

CHECK FOR HIDDEN TABLES ABOVE THIS LINE! - Unhide Tables for overwriting them with new actu

DO NOT CUT CELLS IN THIS TAB !


COPY, COPY &PASTE ARE OK !

Manualy enter NPSH and/or Lift data in shaded cells

Optional Inputs

paste tables and graphs in Log tab


NPSH

gauge_h

P_barom.: 34.3

Not Linked Values


Head -Psi

Head - ft

0.00
0.00
0.00
0.00
0.00
0.00
0.00

the CAP template !

Data Point
1
2
3
4
5
6

GPM

40.7
52.7
93.1
125.6
145.3
169.3

NPSH

RPM

0.5
1.5
1.0
1.5
2.0
3.0

1150
1150
1150
1150
1150
1150

0.5

Not Used in This Template


Nominal Values
GPM (Nom)
NPSH

40.68
52.72
93.06
125.57
145.33
169.28

0.50
1.50
1.00
1.50
2.00
3.00

No warning
No warning

`
Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

it Coefficients

gpm

C heck-up !

% Error

3.926E-01

150

1.3

0.11%

2.981E+01

150

20.0

0.03%

1.416E+01

150

59.7

-0.05%

Data Point

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

0.00%

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.00%
1.114E+02

Max error:

BHP

% Eff.

1.1

67.5

0.11%

NPSH

gauge_h

P_barom.: 34.3

Not Linked Values


Head -Psi

Head - ft

0.00
0.00
0.00
0.00
0.00
0.00
0.00

the CAP template !

Data Point
1
2
3
4
5
6

GPM

41.3
52.0
93.7
126.9
142.4
167.1
No warning
No warning

NPSH

RPM

0.5
1.5
1.0
1.5
2.0
3.0

1150
1150
1150
1150
1150
1150

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.5

Not Used in This Template


Nominal Values
GPM (Nom)
NPSH

41.32
51.95
93.70
126.91
142.42
167.07

0.50
1.50
1.00
1.50
2.00
3.00

`
Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

it Coefficients

gpm

C heck-up !

% Error

4.952E-01

150

1.2

0.12%

3.022E+01

150

17.4

0.61%

Data Point

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

1.096E+01

150

55.2

0.05%

0.00%

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.00%
1.058E+02

Max error:

BHP

% Eff.

1.0

66.7

0.61%

NPSH

P_barom.: 34.3

gauge_h

Not Linked Values


Head -Psi

Head - ft

0.00
0.00
0.00
0.00
0.00
0.00
0.00

the CAP template !

Data Point
1
2
3
4
5
6

GPM

41.7
50.9
92.8
125.3
132.3
138.0

NPSH

RPM

0.5
0.5
1.0
1.5
1.8
2.0

1150
1150
1150
1150
1150
1150

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.5

Not Used in This Template


Nominal Values
GPM (Nom)
NPSH

41.69
50.93
92.79
125.32
132.35
138.00

0.50
0.50
1.00
1.50
1.75
2.00

No warning
No warning

`
Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

it Coefficients

gpm

C heck-up !

% Error

5.016E-01

140

0.9

-0.54%

3.132E+01

140

13.4

0.64%

6.136E+01

140

50.6

0.99%

Data Point

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

0.00%

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.00%
1.029E+02

Max error:

BHP

% Eff.

0.8

62.6

0.99%

NPSH

P_barom.: 34.3

gauge_h

Not Linked Values


Head -Psi

the CAP template !

Head - ft

0.00
0.00
0.00
0.00
0.00
0.00
0.00

Data Point
1
2
3
4
5
6

GPM

28.7
46.5
89.0
120.1
125.1
131.4
No warning

NPSH

RPM

0.5
0.5
1.0
1.5
1.8
2.0

1150
1150
1150
1150
1150
1150

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.5

Not Used in This Template


Nominal Values
GPM (Nom)
NPSH

28.73
46.48
89.03
120.13
125.06
131.42

0.50
0.50
1.00
1.50
1.75
2.00

No warning

`
Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

it Coefficients

gpm

C heck-up !

% Error
0.90%

4.996E-01

130

0.7

2.097E+01

130

10.0

0.17%

-3.740E+00

130

47.1

-0.99%

Data Point

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

0.00%

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.00%
8.742E+01

Max error:

BHP

% Eff.

0.6

60.1

0.99%

NPSH

P_barom.: 34.3

gauge_h

Not Linked Values


Head -Psi

Head - ft

0.00
0.00
0.00
0.00
0.00
0.00
0.00

the CAP template !

Data Point
1
2
3
4
5
6

GPM

26.4
42.8
83.9
111.5
117.8
124.9

NPSH

RPM

0.5
0.5
1.0
1.5
1.8
2.0

1150
1150
1150
1150
1150
1150

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.5

Not Used in This Template


Nominal Values
GPM (Nom)
NPSH

26.45
42.78
83.91
111.46
117.82
124.87

0.50
0.50
1.00
1.50
1.75
2.00

No warning
No warning

`
Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

it Coefficients

gpm

C heck-up !

% Error

1.043E-01

120

0.6

-0.20%

3.005E+01

120

7.8

0.99%

1.010E+02

120

42.2

0.98%

Data Point

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

0.00%

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.00%
8.330E+01

Max error:

BHP

% Eff.

0.5

57.8

0.99%

NPSH

Not Linked Values

P_barom.: 34.3

gauge_h

0.5

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Not Used in This Template


Nominal Values

Head -Psi

Head - ft

0.00
0.00
0.00
0.00
0.00
0.00
0.00

the CAP template !

Data Point
1
2
3
4
5
6

GPM

24.2
39.1
59.7
77.4
89.4
103.5

NPSH

RPM

GPM (Nom)

NPSH

0.5
0.5
0.8
1.0
1.3
1.5

1150
1150
1150
1150
1150
1150

24.18
39.09
59.67
77.38
89.41
103.53

0.50
0.50
0.75
1.00
1.25
1.50

No warning
No warning

`
Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

it Coefficients

gpm

C heck-up !

% Error

3.449E-02

100

0.4

0.22%

5.209E+00

100

7.7

0.01%

-6.137E+00

100

47.0

0.48%

Data Point

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

0.00%

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.00%
7.320E+01

Max error:

BHP

% Eff.

0.4

56.3

0.48%

NPSH

P_barom.: 34.3

gauge_h

Not Linked Values


Head -Psi

Head - ft

0.00
0.00
0.00
0.00
0.00
0.00
0.00

the CAP template !

Data Point
1
2
3
4
5
6

GPM

21.2
33.3
50.3
70.9
80.8
92.1

NPSH

RPM

0.5
0.5
0.8
1.0
1.3
1.5

1150
1150
1150
1150
1150
1150

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.5

Not Used in This Template


Nominal Values
GPM (Nom)
NPSH

21.19
33.28
50.30
70.86
80.75
92.08

0.50
0.50
0.75
1.00
1.25
1.50

No warning
No warning

`
Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

it Coefficients

gpm

C heck-up !

% Error

2.975E-01

90

0.3

-0.24%

1.641E+01

90

6.0

0.67%

2.527E+01

90

42.8

0.59%

Data Point

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

0.00%
0.00%
6.538E+01

Max error:

BHP

% Eff.

0.3

52.9

0.67%

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!

NPSH

P_barom.: 34.3

gauge_h

Not Linked Values


Head -Psi

Head - ft

0.00
0.00
0.00
0.00
0.00
0.00
0.00

the CAP template !

Data Point
1
2
3
4
5
6

GPM

15.4
27.5
44.5
60.8
69.3
79.9

NPSH

RPM

0.5
0.5
0.8
1.0
1.3
1.5

1150
1150
1150
1150
1150
1150

#DIV/0!
#DIV/0!

0.5

Not Used in This Template


Nominal Values
GPM (Nom)
NPSH

15.36
27.45
44.49
60.80
69.30
79.92

0.50
0.50
0.75
1.00
1.25
1.50

No warning
No warning

`
Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

it Coefficients

gpm

C heck-up !

% Error

-3.674E-01

80

0.2

0.75%

-2.564E+00

80

4.5

-0.34%

1.453E+01

80

40.0

0.23%

Data Point

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

0.00%

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.00%
6.008E+01

Max error:

BHP

% Eff.

0.2

48.0

0.75%

NPSH

P_barom.: 34.3

gauge_h

Not Linked Values


Head -Psi

Head - ft

Data Point

0.00
0.00
0.00
0.00
0.00
0.00
0.00

the CAP template !

GPM

NPSH

0.5

Not Used in This Template


Nominal Values
GPM (Nom)
NPSH

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

No warning
No warning

s are required !

it Coefficients

RPM

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

`
Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

gpm

C heck-up !

% Error

Data Point

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

BHP

#VALUE!

#VALUE!

#VALUE!

#VALUE!

Max error:

#VALUE!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

% Eff.

#VALUE! #VALUE!

NPSH

P_barom.: 34.3

gauge_h

Not Linked Values


Head -Psi

Head - ft

Data Point

0.00
0.00
0.00
0.00
0.00
0.00
0.00

the CAP template !

GPM

NPSH

RPM

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.5

Not Used in This Template


Nominal Values
GPM (Nom)
NPSH

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Speed at NPSH Test is not equal to the nominal curve speed!


Speed at NPSH Test is not equal to the nominal curve speed!

s are required !

`
Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

it Coefficients

gpm

C heck-up !

% Error

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!

#VALUE!
#VALUE!

BHP

#VALUE!

Max error:

#VALUE!

#VALUE! #VALUE!

erwriting them with new actual data !

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

#VALUE!

#VALUE!

% Eff.

Data Point

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Not Used in This Template


Nominal Values
RPM(Nom) P_barom

1150
1150
1150
1150
1150
1150

Gage_h

34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
not used
in this template

velocity correction !
RPM(Nom)

1150
1150
1150
1150
1150
1150

Not Used in This Template


Nominal Values
RPM(Nom) P_barom

1150
1150
1150
1150
1150
1150

velocity correction !
RPM(Nom)

Gage_h

34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
not used
in this template

1150
1150
1150
1150
1150
1150

Not Used in This Template


Nominal Values
RPM(Nom) P_barom

1150
1150
1150
1150
1150
1150

Gage_h

34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
not used
in this template

velocity correction !
RPM(Nom)

1150
1150
1150
1150
1150
1150

Not Used in This Template


Nominal Values
RPM(Nom) P_barom

1150
1150
1150
1150
1150
1150

34.30
34.30
34.30
34.30
34.30
34.30
not used

Gage_h

0.50
0.50
0.50
0.50
0.50
0.50

in this template

velocity correction !
RPM(Nom)

1150
1150
1150
1150
1150
1150

Not Used in This Template


Nominal Values
RPM(Nom) P_barom

1150
1150
1150
1150
1150
1150

Gage_h

34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
not used
in this template

velocity correction !
RPM(Nom)

1150
1150
1150
1150
1150
1150

Not Used in This Template


Nominal Values

RPM(Nom)

1150
1150
1150
1150
1150
1150

P_barom

Gage_h

34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
not used
in this template

velocity correction !
RPM(Nom)

1150
1150
1150
1150
1150
1150

Not Used in This Template


Nominal Values
RPM(Nom) P_barom

1150
1150
1150
1150
1150
1150

velocity correction !
RPM(Nom)

1150
1150
1150
1150

Gage_h

34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
not used
in this template

1150
1150

Not Used in This Template


Nominal Values
RPM(Nom) P_barom

1150
1150
1150
1150
1150
1150

Gage_h

34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
not used
in this template

velocity correction !
RPM(Nom)

1150
1150
1150
1150
1150
1150

Not Used in This Template


Nominal Values
RPM(Nom) P_barom

0
0
0
0
0
0

velocity correction !
RPM(Nom)

Gage_h

34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
not used
in this template

0
0
0
0
0
0

Not Used in This Template


Nominal Values
RPM(Nom) P_barom

3500
3500
3500
3500
3500
3500

velocity correction !
RPM(Nom)

3500
3500
3500
3500
3500
3500

Gage_h

34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
not used
in this template

2.0
Efficiency Trim Coeff.: 0.15
NA
Company: THE DURIRON COMPANY
Date: RPM ratio: 1.000
Fire
Type:
Primary
Secondary

BEP
head
BEP out
1,042
111
67.5%
26
of range
Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq
Disch.inch
ID: 3
Test No

Pump Size

Pump Model

2k3x2-8 DURO MARK III

Data Point

1
2
3
4
5
6
7

Efficiency

GPM

TDH

#N/A
#N/A
#N/A
25.3%
50.1%
66.9%
67.1%
63.2%
59.7%
41.9%
Lift Test:

#N/A
#N/A
#N/A
20.0
50.0
100.0
120.0
140.0
150.0
180.0

#N/A
#N/A
31.0
31.0
30.9
27.8
25.1
22.0
20.0
13.0

Data Point

GPM

NPSH

1
2
3
4
5
6

40.7
52.7
93.1
125.6
145.3
169.3

0.5
1.5
1.0
1.5
2.0
3.0

No NPSH TrimFact: 0.5


2 Owner:
Sumit
Trim Ratio:
1.000
Special Parts/Test Conditions
0
0
gpm
Specific Speed

Imp. D

8.188

Lift Fact:

Pump Size

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Efficiency

1
2
3
4
5
6
7
8

#N/A
#N/A
0.0%
25.3%
50.1%
60.1%
66.0%
65.8%
55.2%
40.4%

1150
BHP

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

RPM

#N/A
1,150
#N/A
1,150
#N/A
1,150
0.6
1,150
0.8
1,150
1.1
1,150
1.1
1,150
1.2
1,150
1.3
1,150
1.4
1,150
#VALUE! #VALUE!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Pump Model

GPM

#N/A
#N/A
0.0
20.0
50.0
70.0
100.0
120.0
150.0
172.0

Imp. D

8.000

100
25
25

yy =
= 9.3173E-08x
-4.7004E-07x
150

100

50

0
0

RPM

Curve
BHP
Head
Efficiency
NPSH
Lift

#VALUE!
Overwrite old data with new on
2k3x2-8
35

150
17
17

68.3% PASS
Suction ID: 2.000
stages
N (rpm)

200

1,150
1,150
1,150
1,150
1,150
1,150

2.0
Efficiency Trim Coeff.: 0.15
NA
Company: THE DURIRON COMPANY
Date: RPM ratio: 1.000
Fire
Type:
Primary
Secondary

2k3x2-8 DURO MARK III

Data Point

250

150
18
20

72.1% PASS
Suction ID: 2.000
stages
N (rpm)

#VALUE! head-drop
GPM-lift
TDH (lift) V-Head Corr.

BEP
head
BEP out
1,064
106
66.7%
25
of range
Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq
Disch.inch
ID: 3
Test No

100
28
28

Scaled Results for Lif-tes


2k3x2-8

Head (feet)

Lift Fact:

1150

TDH

BHP

RPM

#N/A
#N/A
29.0
29.0
29.0
27.9
25.5
23.0
17.3
11.8

#N/A
#N/A
0.5
0.6
0.7
0.8
1.0
1.1
1.2
1.3

1,150
1,150
1,150
1,150
1,150
1,150
1,150
1,150
1,150
1,150

30
25
Head (feet)

No NPSH TrimFact: 0.5


1 Owner:
Sumit
Trim Ratio:
1.000
Special Parts/Test Conditions
0
0
gpm
Specific Speed

20
15
10
5
0
0

NPSH

1
2
3
4
5
6

41.3
52.0
93.7
126.9
142.4
167.1

0.5
1.5
1.0
1.5
2.0
3.0

No NPSH TrimFact: 0.5


3 Owner:
Sumit
Trim Ratio:
1.000
Special Parts/Test Conditions
0
0
gpm
Specific Speed

Lift Fact:

#VALUE! head-drop
#VALUE! #VALUE!
GPM-lift
TDH (lift) V-Head Corr.
RPM

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Pump Size

Pump Model

2k3x2-8 DURO MARK III

Imp. D

7.500

Data Point

Efficiency

GPM

TDH

1
2
3
4
5
6
7
8
9
10

0.0%
25.8%
43.3%
56.1%
60.1%
62.2%
61.0%
56.6%
50.1%
40.0%
Lift Test:

0.0
20.0
40.0
60.0
80.0
100.0
120.0
130.0
140.0
152.0

24.0
24.0
24.0
23.7
22.0
20.2
17.8
15.7
13.3
9.9

Data Point

GPM

NPSH

1
2
3
4
5
6

41.7
50.9
92.8
125.3
132.3
138.0

0.5
0.5
1.0
1.5
1.8
2.0

No NPSH TrimFact: 0.5


4 Owner:
Sumit
Trim Ratio:
1.000
Special Parts/Test Conditions
0
0
gpm
Specific Speed

Lift Fact:

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Pump Size

0
Data Point

1
2

2k3x2-8 DURO MARK III


Efficiency
GPM
0.0%
13.6%

100.0% PASS
Suction ID: 2.000
stages
N (rpm)

1150
BHP

RPM

0.4
1,150
0.5
1,150
0.6
1,150
0.6
1,150
0.7
1,150
0.8
1,150
0.9
1,150
0.9
1,150
0.9
1,150
1.0
1,150
#VALUE! #VALUE!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.0
10.0

Imp. D

7.000

BHP
Head
Efficiency
NPSH
Lift

#VALUE!
Overwrite old data with new on
2k3x2-8
35
30
25

5
0
0

RPM

Curve
BHP
Head
Efficiency
NPSH
Lift

100.0% PASS
Suction ID: 2.000
stages
N (rpm)

15
10

#VALUE!
Overwrite old data with new on
2k3x2-8
25

0
14
21

21
21

20

1,150
1,150
1,150
1,150
1,150
1,150

2.0
Efficiency Trim Coeff.: 0.15
NA
Company: THE DURIRON COMPANY
Date: RPM ratio: 1.000
Fire
Type:
Primary
Secondary

Pump Model

Curve

0
20
31

31
31

#VALUE! head-drop
GPM-lift
TDH (lift) V-Head Corr.

BEP
head
BEP out
#DIV/0!
87
60.1%
17
of range
Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq
Disch.inch
ID: 3
Test No

1,150
1,150
1,150
1,150
1,150
1,150

2.0
Efficiency Trim Coeff.: 0.15
NA
Company: THE DURIRON COMPANY
Date: RPM ratio: 1.000
Fire
Type:
Primary
Secondary

BEP
head
BEP out
#DIV/0!
103
62.6%
20
of range
Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq
Disch.inch
ID: 3
Test No

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Head (feet)

GPM

1150

TDH

BHP

RPM

20.0
20.5

0.4
0.4

1,150
1,150

20

Head (feet)

Lift Test:
Data Point

15

10

26.5%
42.1%
54.3%
59.6%
59.2%
51.9%
47.6%
40.4%
Lift Test:

Data Point

GPM

NPSH

1
2
3
4
5
6

28.7
46.5
89.0
120.1
125.1
131.4

0.5
0.5
1.0
1.5
1.8
2.0

No NPSH TrimFact: 0.5


5 Owner:
Sumit
Trim Ratio:
1.000
Special Parts/Test Conditions
0
0
gpm
Specific Speed

Lift Fact:

20.0
40.0
60.0
80.0
100.0
120.0
130.0
140.0

21.0
20.0
19.7
17.7
15.3
11.8
10.0
8.0

#VALUE! head-drop
GPM-lift
TDH (lift) V-Head Corr.

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Pump Size

Pump Model

2k3x2-8 DURO MARK III

Imp. D

6.500

Data Point

Efficiency

GPM

TDH

1
2
3
4
5
6
7
8
9
10

0.0%
24.6%
34.7%
43.2%
56.4%
57.7%
55.4%
50.9%
41.8%
36.6%
Lift Test:

0.0
20.0
30.0
40.0
60.0
80.0
100.0
110.0
120.0
125.0

17.6
17.5
17.4
17.1
16.0
14.0
11.6
10.0
7.7
6.5

Data Point

GPM

NPSH

1
2
3
4
5
6

26.4
42.8
83.9
111.5
117.8
124.9

0.5
0.5
1.0
1.5
1.8
2.0

No NPSH TrimFact: 0.5


6 Owner:
Sumit
Trim Ratio:
1.000
Special Parts/Test Conditions
0
0

Lift Fact:

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

30
30

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

BHP
Head
Efficiency
NPSH
Lift

BHP

RPM

0.3
1,150
0.4
1,150
0.4
1,150
0.4
1,150
0.4
1,150
0.5
1,150
0.5
1,150
0.5
1,150
0.6
1,150
0.6
1,150
#VALUE! #VALUE!

2k3x2-8
35
30
25
20
15
10
5
0
0

RPM

Curve

1,150
1,150
1,150
1,150
1,150
1,150

BHP
Head
Efficiency
NPSH
Lift

2.0
Efficiency Trim Coeff.: 0.15
NA
Company: THE DURIRON COMPANY
Date: RPM ratio: 1.000
Fire
Type:
Primary
Secondary

#VALUE!
Overwrite old data with new on

0
20
30

1150

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Curve

#VALUE! head-drop
GPM-lift
TDH (lift) V-Head Corr.

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

RPM

100.0% PASS
Suction ID: 2.000
stages
N (rpm)

1,150
1,150
1,150
1,150
1,150
1,150

2.0
Efficiency Trim Coeff.: 0.15
NA
Company: THE DURIRON COMPANY
Date: RPM ratio: 1.000
Fire
Type:
Primary
Secondary

BEP
head
BEP out
#DIV/0!
83
57.8%
14
of range
Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq
Disch.inch
ID: 3
Test No

0.4
1,150
0.5
1,150
0.6
1,150
0.6
1,150
0.7
1,150
0.7
1,150
0.7
1,150
0.7
1,150
#VALUE! #VALUE!

Head (feet)

3
4
5
6
7
8
9
10

0
3

#VALUE!
Overwrite old data with new on
2k3x2-8
16
14

Pump Size

Pump Model

2k3x2-8 DURO MARK III


Efficiency
GPM

Data Point

1
2
3
4
5
6
7
8
9
10

0.0%
13.8%
24.9%
35.7%
42.9%
49.8%
53.8%
56.0%
46.7%
36.6%
Lift Test:

Data Point

GPM

NPSH

1
2
3
4
5
6

24.2
39.1
59.7
77.4
89.4
103.5

0.5
0.5
0.8
1.0
1.3
1.5

No NPSH TrimFact: 0.5


7 Owner:
Sumit
Trim Ratio:
1.000
Special Parts/Test Conditions
0
0
gpm
Specific Speed

Lift Fact:

0.0
10.0
20.0
30.0
40.0
50.0
60.0
80.0
100.0
112.0

Imp. D

6.000

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Pump Size

Pump Model

Imp. D

5.500

Data Point

Efficiency

GPM

TDH

1
2
3
4
5
6
7
8
9
10

0.0%
24.0%
34.4%
41.9%
50.0%
52.7%
52.3%
50.0%
42.5%
31.6%
Lift Test:

0.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0

11.8
11.9
11.8
11.2
10.9
10.0
9.0
7.7
6.0
4.0

GPM

NPSH

1
2
3
4

21.2
33.3
50.3
70.9

0.5
0.5
0.8
1.0

RPM

0.3
1,150
0.3
1,150
0.3
1,150
0.3
1,150
0.3
1,150
0.4
1,150
0.4
1,150
0.4
1,150
0.4
1,150
0.4
1,150
#VALUE! #VALUE!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

16
16

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

4
2
0
0

BHP
Head
Efficiency
NPSH
Lift

#VALUE!
Overwrite old data with new on
2k3x2-8
18

0
11
16

RPM

0.2
1,150
0.3
1,150
0.3
1,150
0.3
1,150
0.3
1,150
0.3
1,150
0.3
1,150
0.3
1,150
0.3
1,150
0.3
1,150
#VALUE!
#VALUE!

#VALUE! head-drop
GPM-lift
TDH (lift) V-Head Corr.

Curve

1150
BHP

RPM

100.0% PASS
Suction ID: 2.000
stages
N (rpm)

10

1,150
1,150
1,150
1,150
1,150
1,150

2.0
Efficiency Trim Coeff.: 0.15
NA
Company: THE DURIRON COMPANY
Date: RPM ratio: 1.000
Fire
Type:
Primary
Secondary

2k3x2-8 DURO MARK III

Data Point

12

1150
BHP

#VALUE! head-drop
GPM-lift
TDH (lift) V-Head Corr.

BEP
head
BEP out
#DIV/0!
65
52.9%
9
of range
Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq
Disch.inch
ID: 3
Test No

TDH

14.8
14.8
14.8
14.6
14.0
14.0
13.5
11.0
7.7
5.7

5
Head (feet)

Test No

100.0% PASS
Suction ID: 2.000
stages
N (rpm)

16
14
12
Head (feet)

gpm
BEP
head
BEP out
#DIV/0!
73
56.3%
12
of range
Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq
Disch.inch
ID: 3
Specific Speed

10
8
6
4
2
0
0

RPM

Curve

1,150
1,150
1,150
1,150

BHP
Head
Efficiency
NPSH

No NPSH TrimFact: 0.5


8 Owner:
Sumit
Trim Ratio:
1.000
Special Parts/Test Conditions
0
0
gpm
Specific Speed

1.3
1.5
Lift Fact:

#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!

Pump Size

Pump Model

2k3x2-8 DURO MARK III

Imp. D

Efficiency

GPM

TDH

1
2
3
4
5
6
7
8
9
10

0.0%
13.2%
24.7%
33.5%
42.1%
46.5%
47.9%
46.4%
39.9%
25.8%
Lift Test:

0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
92.0

8.9
8.9
8.8
8.4
8.0
7.9
7.0
5.8
4.5
3.0

GPM

NPSH

1
2
3
4
5
6

15.4
27.5
44.5
60.8
69.3
79.9

0.5
0.5
0.8
1.0
1.3
1.5

No NPSH TrimFact: 0.5


9 Owner:
Sumit
Trim Ratio:
1.000
Special Parts/Test Conditions
0
0
gpm
Specific Speed

Lift Fact:

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0
Data Point

Pump Size

Pump Model

2k3x2-8 DURO MARK III


Efficiency
GPM
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

1150
BHP

RPM

0.2
1,150
0.2
1,150
0.2
1,150
0.2
1,150
0.2
1,150
0.2
1,150
0.2
1,150
0.2
1,150
0.2
1,150
0.3
1,150
#VALUE!
#VALUE!

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Imp. D

0.000
TDH

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

2k3x2-8
10

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

8
6
4
2
0
0
-2
-4

RPM

Curve

1,150
1,150
1,150
1,150
1,150
1,150

BHP
Head
Efficiency
NPSH
Lift

2.0
Efficiency Trim Coeff.: 0.15
NA
Company: THE DURIRON COMPANY
Date: RPM ratio: 1.000
Fire
Type:
Primary
Secondary

BEP
head
#VALUE!
#DIV/0!
#VALUE!
#VALUE! #VALUE!
#VALUE!
Semi open,STD-A05,Max sphere 13/32,eye area 3.5sq
Disch.inch
ID: 2
Test No

100.0% PASS
Suction ID: 2.000
stages
N (rpm)

#VALUE! head-drop
GPM-lift
TDH (lift) V-Head Corr.

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Lift

#VALUE!
Overwrite old data with new on

0
-2
-3

-3
-3

5.000

Data Point

Data Point

1,150
1,150

2.0
Efficiency Trim Coeff.: 0.15
NA
Company: THE DURIRON COMPANY
Date: RPM ratio: 1.000
Fire
Type:
Primary
Secondary

BEP
head
BEP out
#DIV/0!
60
48.0%
7
of range
Semi open,STD-A60,Max sphere 17/32,eye area 6.8sq
Disch.inch
ID: 3
Test No

#DIV/0!
#DIV/0!

Head (feet)

80.8
92.1

#VALUE!
Overwrite old data with new on
2k3x2-8
1

0
#VALUE! #VALUE!
#VALUE! #VALUE!

#VALUE! #VALUE!
Suction ID: 1.000
stages
N (rpm)

#DIV/0!
BHP

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

RPM

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Head (feet)

5
6

1
1
0
0
0
0
0
0

Data Point

1
2
3
4
5
6

GPM

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

No NPSH TrimFact: 0.5


10 Owner:
Sumit
Trim Ratio:
1.000
Special Parts/Test Conditions
0
0
gpm
Specific Speed

NPSH

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
Lift Fact:

#N/A
#N/A

#N/A
#N/A

#VALUE! head-drop
GPM-lift
TDH (lift) V-Head Corr.

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
Lift Test:
Data Point

1
2
3
4
5
6

Pump Model

2k3x2-8 DURO MARK III


Efficiency
GPM

Data Point

GPM

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Primary

Pump Size

NPSH

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

RPM

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
2.0
Efficiency Trim Coeff.: 0.15
NA
Company: THE DURIRON COMPANY
Date: RPM ratio: 1.000
Fire
Type:

BEP
head
#VALUE!
#VALUE!
#VALUE!
#VALUE! #VALUE!
#VALUE!
Semi open,STD-A05,Max sphere 13/32,eye area 3.5sq
Disch.inch
ID: 2
Test No

#N/A
#N/A
#N/A
#N/A
#VALUE! #VALUE!

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

Imp. D

0.000
TDH

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

BHP
Head
Efficiency
NPSH
Lift

#VALUE!
Overwrite old data with new on
2k3x2-8
1

Secondary

0
#VALUE! #VALUE!
#VALUE! #VALUE!

#VALUE! #VALUE!
Suction ID: 1.000
stages
N (rpm)

3500
BHP

RPM

#N/A
3,500
#N/A
3,500
#N/A
3,500
#N/A
3,500
#N/A
3,500
#N/A
3,500
#N/A
3,500
#N/A
3,500
#N/A
3,500
#N/A
3,500
#VALUE! #VALUE!

#VALUE! head-drop
GPM-lift
TDH (lift) V-Head Corr.

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Curve

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Head (feet)

#N/A
#N/A
Lift Test:

1
1
0
0
0
0
0
0

RPM

Curve

3,500
3,500
3,500
3,500
3,500
3,500

BHP
Head
Efficiency
NPSH
Lift

#VALUE!

CHECK FOR HIDDEN TABLES ABOVE THIS LINE! - Unhide Tables for overwriting them with new actual data !

Unhide the rows below this line to compare up to 3 sets of curves by Copy&Paste Special-Values any of the abov

Pump 1

Primary

Trim Ratio:

1000

Special Parts/Test Conditions


0
0
gpm
Specific Speed

Test No

Secondary
Primary

BEP

head

Pump Size

Disch. ID:
Pump Model

1500

Pump

Type:

RPM ratio:

0
0
0

Secondary

Imp. D

Suction ID:
stages

N (rpm)

Efficiency

GPM

TDH

BHP

RPM

#N/A
#N/A

#DIV/0!
#DIV/0!

#N/A
#N/A

#N/A
#N/A

#N/A
#N/A

#N/A
#N/A

Data Point

Lift Test:
NPSH

GPM

#VALUE!
GPM-lift

head-drop #VALUE!
TDH (lift)
V-Head Corr.

#VALUE!
RPM

Head [feet], Power [hp]

Data Point

Pump2

Primary

Trim Ratio:

Special Parts/Test Conditions


0
0
gpm
Specific Speed

Test No
Data Point

1000

Secondary
Primary

BEP

head

Pump Size

Disch. ID:
Pump Model

Efficiency

GPM

1500

Type:

RPM ratio:

Imp. D
TDH

Suction ID:
stages
BHP

0
0

Secondary

Curve
BHP
Head
Efficiency
NPSH
Lift

N (rpm)

RPM

Curve
BHP
Head
Efficiency
NPSH
Lift

Curve
BHP
Head

Data Point

Lift Test:
NPSH

GPM

Pump3

Primary

Trim Ratio:

head-drop #VALUE!
TDH (lift)
V-Head Corr.

1000

Test No
Data Point

GPM

BEP

head

Pump Size

Disch. ID:
Pump Model

Efficiency

GPM

Lift Test:
NPSH

#VALUE!
GPM-lift

Secondary

#VALUE!
RPM

1500

Type:

RPM ratio:

Special Parts/Test Conditions


0
0
gpm
Specific Speed

Data Point

#VALUE!
GPM-lift

Imp. D
TDH

Primary

Secondary

Suction ID:
stages

N (rpm)

BHP

RPM

head-drop #VALUE!
TDH (lift)
V-Head Corr.

#VALUE!
RPM

Efficiency
NPSH
Lift

Scaled Results for Lif-test are not relayable !


Test Curve

1150 rpm

Scaled results for NPSH may not be true


8.188
in Impeller
Head-Data
Lift
Primary-Secondary
Power-Data

2
-08x33--3.7406E-05x
4.7004E-07x
7.7800E-04x2++9.3665E-03x
6.1904E-02x++3.9265E-01
2.9811E+01

100

200

300

400

500

Q (gpm)

Curve Coefficients

Coeff-3
9.31730E-08
-4.70035E-07
-6.32532E-08
2.44714E-06
#VALUE!

Coeff-2
-3.74056E-05
-7.77996E-04
-2.88573E-05
-7.00887E-04
#VALUE!

Check Curve !

Coeff-1
Coeff-0
9.36652E-03 3.92649E-01
6.19040E-02 2.98113E+01
8.78554E-03 1.41616E-01
8.02409E-02 -2.36967E+00
#VALUE!
#VALUE!

150
150
150
150
150
% Head Drop at Secondary Point at Lift-Test :

Overwrite old data with new one in Input-tab. Copy&Paste additional data-blocks if necessary
1150 rpm
8.000
Test Curve
0

Y
1
20
59.7%
2.2
#VALUE!
#VALUE!
in Impeller

Head- Data
Lift
Primary-Secondary
Power-Data

y = -3.1835E-06x3 + 3.5819E-05x2 - 1.9332E-02x + 3.0223E+01

20

40

60

80

100

120

Q (gpm)+ 4.9521E-01
y = -4.1846E-08x3 + 8.0122E-06x2 + 4.3596E-03x

140

160

180

200

Curve Coefficients

Coeff-3
Coeff-2
Coeff-1
-4.18457E-08 8.01219E-06 4.35965E-03
-3.18345E-06 3.58193E-05 -1.93320E-02
-5.89564E-08 -3.73107E-05 9.87152E-03
-1.97753E-06 1.07048E-03 -1.48374E-01
#VALUE!
#VALUE!
#VALUE!

Check Curve !

Coeff-0
4.95209E-01
3.02232E+01
1.09561E-01
7.13099E+00
#VALUE!

150
150
150
150
150
% Head Drop at Secondary Point at Lift-Test :

Overwrite old data with new one in Input-tab. Copy&Paste additional data-blocks if necessary
1150 rpm
7.500
Test Curve
0

Y
1
17
55.2%
2.3
#VALUE!
#VALUE!
in Impeller

Head-Data
Lift

y=

-1.2714E-05x3

2.6098E-03x2

Primary-Secondary

- 2.4411E-01x + 3.1315E+01

Power-Data

20

40

60

80

100

120

140

160

2 + 8.0923E-04x + 5.0160E-01
Q (gpm)
y = -1.8111E-07x3 + 4.1683E-05x

Curve Coefficients

Coeff-3
Coeff-2
-1.81114E-07 4.16833E-05
-1.27136E-05 2.60978E-03
-6.13481E-07 1.25016E-04
3.92922E-06 -8.67047E-04
#VALUE!
#VALUE!

Coeff-1
8.09228E-04
-2.44112E-01
-6.24701E-03
6.32559E-02
#VALUE!

Check Curve !

Coeff-0
5.01604E-01
3.13152E+01
6.13584E-01
-5.43405E-01
#VALUE!

0
0
0
0
0
% Head Drop at Secondary Point at Lift-Test :

Overwrite old data with new one in Input-tab. Copy&Paste additional data-blocks if necessary
1150 rpm
7.000
Test Curve
0

y = 5.0243E-07x3 - 9.9177E-04x2 + 3.6161E-02x + 2.0973E+01

Y
1
31
61.4%
-0.5
#VALUE!
#VALUE!
in Impeller

Head-Data
Lift
Primary-Secondary
Power-Data

20
40
60
80
100
y = -2.4497E-07x3 + 5.6261E-05x2 - 1.6606E-03x + 4.9957E-01
Q (gpm)

120

Curve Coefficients

140

160

Check Curve !

Coeff-3
Coeff-2
Coeff-1
Coeff-0
-2.44975E-07 5.62613E-05 -1.66065E-03 4.99573E-01
5.02434E-07 -9.91769E-04 3.61611E-02 2.09730E+01
9.05741E-08 -9.94011E-05 1.53031E-02 -3.74034E-02
-4.65427E-05 1.65170E-02 -1.90025E+00 7.21043E+01
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0
0
0
0
0
% Head Drop at Secondary Point at Lift-Test :

Overwrite old data with new one in Input-tab. Copy&Paste additional data-blocks if necessary
1150 rpm
6.500
Test Curve
0

Y
0
21
-3.7%
72.1
#VALUE!
#VALUE!
in Impeller

Head-Data

y = -2.1633E-05x3 + 4.7016E-03x2 - 4.3834E-01x + 3.0048E+01

Lift
Primary-Secondary
Power-Data

20

40

60

80

100

120

140

(gpm)
y = 8.5720E-08x3 - 4.3216E-05x2 +Q7.7169E-03x
+ 1.0428E-01

Curve Coefficients

Check Curve !

Coeff-3
Coeff-2
Coeff-1
Coeff-0
8.57205E-08 -4.32162E-05 7.71688E-03 1.04279E-01
-2.16332E-05 4.70156E-03 -4.38343E-01 3.00483E+01
-1.48214E-06 3.09136E-04 -2.06492E-02 1.00988E+00
-2.22349E-05 7.58785E-03 -8.23551E-01 2.98154E+01
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0
0
0
0
0
% Head Drop at Secondary Point at Lift-Test :

Overwrite old data with new one in Input-tab. Copy&Paste additional data-blocks if necessary
1150 rpm
6.000
Test Curve
0
y=

2.1255E-05x3

6.2181E-03x2

Y
0
30
101.0%
29.8
#VALUE!
#VALUE!
in Impeller

+ 4.3418E-01x + 5.2087E+00
Head-Data
Lift

Lift
Primary-Secondary
Power-Data

20

40

60

80

100

120

Q 2(gpm)
y = 5.7673E-07x3 - 1.3960E-04x
+ 1.2017E-02x + 3.4495E-02

Curve Coefficients

Check Curve !

Coeff-3
Coeff-2
Coeff-1
Coeff-0
5.76735E-07 -1.39595E-04 1.20165E-02 3.44947E-02
2.12554E-05 -6.21814E-03 4.34179E-01 5.20872E+00
-1.28860E-07 -9.75883E-05 1.63579E-02 -6.13739E-02
-7.79288E-06 1.98905E-03 -1.48098E-01 4.16064E+00
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0
0
0
0
0
% Head Drop at Secondary Point at Lift-Test :

Overwrite old data with new one in Input-tab. Copy&Paste additional data-blocks if necessary
1150 rpm
5.500
Test Curve
0

y = -1.5370E-05x3 + 2.0298E-03x2 - 1.7350E-01x + 1.6409E+01

Y
0
5
-6.1%
4.2
#VALUE!
#VALUE!
in Impeller

Head-Data
Lift
Primary-Secondary
Power-Data

20

40

60

80

100

120

Q (gpm)
y = -3.7963E-07x3 + 7.0595E-05x2 - 3.0370E-03x
+ 2.9749E-01

Curve Coefficients

Coeff-3
-3.79630E-07
-1.53704E-05
-1.14078E-06
-1.39434E-05

Coeff-2
Coeff-1
Coeff-0
7.05952E-05 -3.03704E-03 2.97492E-01
2.02976E-03 -1.73499E-01 1.64094E+01
8.43895E-05 3.59310E-03 2.52656E-01
3.24656E-03 -2.26212E-01 5.68887E+00

Check Curve !

X
0
0
0
0

Y
0
16
25.3%
5.7

#VALUE!

#VALUE!

#VALUE!

#VALUE!

0
% Head Drop at Secondary Point at Lift-Test :

Overwrite old data with new one in Input-tab. Copy&Paste additional data-blocks if necessary
1150 rpm
5.000
Test Curve
0

#VALUE!
#VALUE!
in Impeller

y = 4.0686E-05x3 - 9.2890E-03x2 + 5.7075E-01x - 2.5644E+00

Head-Data
Lift
Primary-Secondary
Power-Data

10

20

30

40

50

60

70

80

90

100

y = 2.2786E-06x3 - 4.3626E-04x2 + 2.7773E-02x - 3.6736E-01


Q (gpm)

Curve Coefficients

Check Curve !

Coeff-3
Coeff-2
Coeff-1
Coeff-0
2.27859E-06 -4.36265E-04 2.77731E-02 -3.67364E-01
4.06861E-05 -9.28895E-03 5.70748E-01 -2.56436E+00
-1.36320E-06 7.09769E-05 6.23246E-03 1.45342E-01
-2.47527E-05 4.89018E-03 -2.92111E-01 6.24636E+00
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0
0
0
0
0
% Head Drop at Secondary Point at Lift-Test :

Overwrite old data with new one in Input-tab. Copy&Paste additional data-blocks if necessary
#DIV/0!
rpm
0.000
Test Curve
0

Y
0
-3
14.5%
6.2
#VALUE!
#VALUE!
in Impeller

Head-Data
Lift
Primary-Secondary
Power-Data

1
Q (gpm)

Q (gpm)

Curve Coefficients

Coeff-3
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Coeff-2
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Check Curve !

Coeff-1
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Coeff-0
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0
0
0
0
0
% Head Drop at Secondary Point at Lift-Test :

Overwrite old data with new one in Input-tab. Copy&Paste additional data-blocks if necessary
3500 rpm
0.000
Test Curve
0

Y
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
in Impeller

Head-Data
Lift
Primary-Secondary
Power-Data

Q (gpm)

Curve Coefficients

Coeff-3
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Coeff-2
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Coeff-1
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Check Curve !

Coeff-0
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0
0
0
0
0
% Head Drop at Secondary Point at Lift-Test :

with new actual data !

pecial-Values any of the above block of data in the designated 3 blocks below

Y
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Curve

Trim [inch]

Speed [rpm]

0
0
0

0.000
0.000
0.000

0
0
0

Other Conditions

Head [ft]

0
0
0

#VALUE!
#VALUE!
#VALUE!

Data at secondary flow (GPM) =


Power [hp]

#VALUE!
#VALUE!
#VALUE!

Poly. (Pump1)
Poly. (Pump2)
Poly. (Pump3)

Scaled Results for Lif-test are not relayable !


0

Coeff-3
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Curve Coefficients
of Pump1 1
0

Coeff-2
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Coeff-1
Coeff-0
Q [gpm]
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Curve Coefficients of Pump2

Coeff-3
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Coeff-2
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Coeff-1
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Coeff-0
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Coeff-2
#VALUE!
#VALUE!

Coeff-1
#VALUE!
#VALUE!

Check
Curve !
1

Y
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

1500
1500
1500
1500
1500
% Drop at Secondary Point:
Check Curve !

X
1500
1500
1500
1500

1500

Y
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

% Drop at Secondary Point:


Check Curve !

Curve Coefficients of Pump3

Coeff-3
#VALUE!
#VALUE!

Coeff-0
#VALUE!
#VALUE!

X
1500
1500

Y
#VALUE!
#VALUE!

#VALUE!
#VALUE!
#VALUE!

#VALUE!
#VALUE!
#VALUE!

#VALUE!
#VALUE!
#VALUE!

#VALUE!
#VALUE!
#VALUE!

1500
1500
1500
% Drop at Secondary Point:

#VALUE!
#VALUE!
#VALUE!
#VALUE!

1
2k3x2-8

Test Curve

Company:
THE DURIRON COMPANY 1150 rpm
8.188 in Impeller
90%

NPSH-Data
NPSH @ Q2

Eff-Data

80%

70%

2
60%

Eff

NPSH (feet)

2
50%

y = 2.4471E-06x3 - 7.0089E-04x2 + 8.0241E-02x - 2.3697E+00


1

40%

1
0
0
100
200
300
y = -6.3253E-08x3 - 2.8857E-05x2 + 8.7855E-03x + 1.4162E-01
Q (gpm)

400

30%
500

Equation fit coefficients are applicable at :


gpm
minimum-gpm Max Error at gpm

Max Error at
-0.3%
-0.4%
-0.1%
0.0%
#DIV/0!
-0.37%
2

120
120
120
93
#DIV/0!
120

2k3x2-8

Test Curve

50.0
50.0
50.0
93.1
#DIV/0!

Company:
THE DURIRON COMPANY 1150 rpm
8.000 in Impeller
70%

NPSH-Data
NPSH @Q2

60%

Eff-Data

50%

40%

30%

20%

y = -1.9775E-06x3 + 1.0705E-03x2 - 1.4837E-01x + 7.1310E+00 10%

Eff

NPSH (feet)

0
0

y = -5.8956E-08x3 - 3.7311E-05x2 + 9.8715E-03x + 1.0956E-01


50
100
150
Q (gpm)

0%
200

Equation fit coefficients are applicable at :


gpm
minimum-gpm

Max Error at
-0.6%
-0.6%
-0.7%
0.0%
#DIV/0!
-0.70%
3

70
150
100
94
#DIV/0!
100

2k3x2-8

Test Curve
3

50.0
50.0
50.0
93.7
#DIV/0!
Company:
THE DURIRON COMPANY 1150 rpm
7.500 in Impeller

70%

NPSH-Data
NPSH @Q2

60%

Eff-Data

50%

40%

30%

Eff

NPSH (feet)

0
0

20

20%
60
80
100
120
140
160
3
2
y = 3.9292E-06x - 8.6705E-04x + 6.3256E-02x - 5.4341E-01

40

-1

10%

-1

2 - 6.2470E-03x + 6.1358E-01
y = -6.1348E-07x3Q
+ 1.2502E-04x
(gpm)

Equation fit coefficients are applicable at :


gpm
minimum-gpm

Max Error at
0.5%
0.9%
-1.0%
0.0%
#DIV/0!
-1.00%
4

140
120
140
132
#DIV/0!
140

2k3x2-8

Test Curve

80
70

NPSH-Data

80.0
80.0
80.0
92.8
#DIV/0!

Company:
THE DURIRON COMPANY 1150 rpm
7.000 in Impeller
70%
60%
50%

50
40%
40

Eff

NPSH (feet)

Scaled Results for Lif-test are not relayable !

NPSH @ Q2
Eff-Data

60

0%

30%
30

NPSH (feet)

30
20%

20

10%

10

y = 9.0574E-08x3 - 9.9401E-05x2 + 1.5303E-02x - 3.7403E-02

0
0

20

0%
60
80
100
120
140
160
3
2
y = -4.6543E-05x
Q (gpm) + 1.6517E-02x - 1.9003E+00x + 7.2104E+01

40

Equation fit coefficients are applicable at :


gpm
minimum-gpm

Max Error at
-0.9%
0.7%
-1.0%
0.0%
#DIV/0!
-1.00%
5

130
100
120
125
#DIV/0!
120

2k3x2-8

Test Curve

35

Scaled Results for Lif-test are not relayable !


Scaled results for NPSH may not be true

60.0
60.0
60.0
89.0
#DIV/0!
Company:
THE DURIRON COMPANY 1150 rpm
6.500 in Impeller

70%

NPSH-Data
NPSH @ Q2

60%

Eff-Data

25

50%

20

40%

15

30%

10

20%

Eff

NPSH (feet)

30

10%

y = -1.4821E-06x3 + 3.0914E-04x2 - 2.0649E-02x + 1.0099E+00


0
0

20

0%
60
80
100
120
140
3
2
y = -2.2235E-05x
Q (gpm) + 7.5878E-03x - 8.2355E-01x + 2.9815E+01

40

Equation fit coefficients are applicable at :


gpm
minimum-gpm

Max Error at
-0.5%
-1.0%
-1.0%
0.0%
#DIV/0!
-1.00%
6

100
120
120
84
#DIV/0!
120

2k3x2-8

Test Curve

35

NPSH-Data

Scaled Results for Lif-test are not relayable !


Scaled results for NPSH may not be true

60.0
60.0
60.0
83.9
#DIV/0!

Company:
THE DURIRON COMPANY 1150 rpm
6.000 in Impeller
60%

NPSH @ Q2

30

Eff-Data

50%

30

50%

Eff-Data

40%

20
30%

Eff

NPSH (feet)

25

15
20%

10

y = -1.2886E-07x3 - 9.7588E-05x2 + 1.6358E-02x - 6.1374E-02

5
0
0

20

0%
40
60 3
80 2
100
120
y = -7.7929E-06x
+ 1.9890E-03x - 1.4810E-01x + 4.1606E+00
Q (gpm)

Equation fit coefficients are applicable at :


Max Error at gpm
minimum-gpm

-1.0%
-0.3%
0.5%
0.0%
#DIV/0!
-0.99%
7

50
50
80
60
#DIV/0!
50

2k3x2-8

Test Curve

35

10%

Scaled Results for Lif-test are not relayable !


Scaled results for NPSH may not be true

40.0
40.0
40.0
59.7
#DIV/0!

Company:
THE DURIRON COMPANY 1150 rpm
5.500 in Impeller
60%

NPSH-Data
NPSH @ Q2

30

50%

Eff-Data

40%

20
30%
15
20%

10

10%

y = -1.1408E-06x3 + 8.4390E-05x2 + 3.5931E-03x + 2.5266E-01


0
0

20

40
60
80
100
2 - 2.2621E-01x + 5.6889E+00
y = -1.3943E-05x3 Q
+ 3.2466E-03x
(gpm)

Equation fit coefficients are applicable at :


gpm
minimum-gpm

Max Error at
0.8%
-0.7%
0.9%
0.0%

70
90
80
50

50.0
50.0
50.0
50.3

0%
120

Scaled Results for Lif-test are not relayable !


Scaled results for NPSH may not be true

Eff

NPSH (feet)

25

#DIV/0!
0.87%
8

#DIV/0!
80

2k3x2-8

Test Curve

35

#DIV/0!
Company:
THE DURIRON COMPANY 1150 rpm
5.000 in Impeller

60%

NPSH-Data
NPSH @ Q2

30

50%

Eff-Data

40%

20
30%

Eff

NPSH (feet)

25

15
20%

10

10%

5
0
0

y = -1.3632E-06x3 + 7.0977E-05x2 + 6.2325E-03x + 1.4534E-01


0%
20
40
60
80
100
3 + 4.8902E-03x2 - 2.9211E-01x + 6.2464E+00
y = -2.4753E-05x
Q (gpm)

Equation fit coefficients are applicable at :


gpm
minimum-gpm

Max Error at
-0.9%
0.3%
0.4%
0.0%
#DIV/0!
-0.87%
9

50
80
70
80
#DIV/0!
50

2k3x2-8

Test Curve

35

Scaled Results for Lif-test are not relayable !


Scaled results for NPSH may not be true

40.0
40.0
40.0
44.5
#DIV/0!
Company:
#DIV/0!

THE DURIRON COMPANY rpm


0.000 in Impeller
120%

NPSH-Data
NPSH @ Q2

30

100%

Eff-Data

80%

20
60%
15
40%

10

20%

5
0

0%
0

Eff

NPSH (feet)

25

0%
0

Q (gpm)

Scaled Results for Lif-test are not relayable !


Scaled results for NPSH may not be true

Equation fit coefficients are applicable at :


gpm
minimum-gpm

Max Error at
0.0%
0.0%
0.0%
0.0%
#DIV/0!
0.00%
10

#N/A
#N/A
#N/A
#DIV/0!
#DIV/0!
#N/A

2k3x2-8

Test Curve

35

#N/A
#N/A
#N/A
#DIV/0!
#DIV/0!
Company:
THE DURIRON COMPANY 3500 rpm
0.000 in Impeller

70%

NPSH-Data
NPSH @ Q2

60%

Eff-Data

25

50%

20

40%

15

30%

10

20%

Eff

NPSH (feet)

30

10%

y = -1.4821E-06x3 + 3.0914E-04x2 - 2.0649E-02x + 1.0099E+00


0
0

20

40

60

Equation fit coefficients are applicable at :


gpm
minimum-gpm

Max Error at
0.0%
0.0%
0.0%
0.0%
#DIV/0!
0.00%

-0.9%
0.5%
-1.0%
0.9%
-1.0%
-0.1%

#N/A
#N/A
#N/A
#DIV/0!
#DIV/0!
#N/A

#N/A
#N/A
#N/A
#DIV/0!
#DIV/0!

Minumum BHP-error value


Maximum BHP-error value
Minumum Head-error value
Maximum Head-error value
Minumum Efficiency-error
Maximum Efficiency-error

80
Q (gpm)

100

120

0%
140

Scaled Results for Lif-test are not relayable !


Scaled results for NPSH may not be true

ta at secondary flow (GPM) = 1500


Efficiency
NPSH [ft]

#VALUE!
#VALUE!
#VALUE!

Pump

Curve

Trim [inch]

Speed [rpm]

0
0
0

0.000
0.000
0.000

0
0
0

0
0
0

#VALUE!
#VALUE!
#VALUE!

NPSH [feet]

#VALUE!
#VALUE!
#VALUE!

Lift [ft]

Poly. (Pump1)
Poly. (Pump2)
Poly. (Pump3)

Scaled results for NPSH may not be true

0
0

Q [gpm]

Other Conditions

0
0
0

No
1
% Error [(Data-Eq)/Data]
TDH

As per equation
BHP

Efficiency

0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.86%
8.75%
-0.01%
-0.01%
0.17%
0.15%
-0.37%
-0.31%
0.28%
0.29%
-0.03%
-0.11%
-0.04%
0.00%
% Error [(Data-Eq)/Data]

0.0%
0.0%
0.0%
-20.9%
0.0%
0.0%
-0.1%
0.0%
0.0%
0.0%

NPSH

120.15%
81.93%
0.00%
0.00%
0.00%
0.00%

GPM

#N/A
#N/A
#N/A
20.0
50.0
100.0
120.0
140.0
150.0
180.0
As per equation

TDH (lift)

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

No
2
% Error [(Data-Eq)/Data]

TDH

BHP

Efficiency

30.7
30.9
27.8
25.2
21.9
20.0
13.0

#N/A
#N/A
#N/A
0.6
0.8
1.0
1.1
1.2
1.3
1.4

#N/A
#N/A
#N/A
30.5%
50.1%
66.8%
67.1%
63.2%
59.7%
41.9%

#N/A
#N/A
#N/A

GPM

NPSH

40.7
52.7
93.1
125.6
145.3
169.3

-0.1
0.3
1.0
1.5
2.0
3.0

GPM-lift

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

TDH (lift)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

As per equation

TDH

BHP

Efficiency

0.00%
0.00%
-4.22%
-2.85%
0.14%
-0.34%
0.14%
0.36%
-0.61%
0.35%

0.00%
0.00%
-3.17%
-0.91%
0.28%
-0.65%
0.63%
-0.21%
-0.12%
0.07%

0.0%
0.0%
0.0%
-15.5%
-0.2%
0.5%
-0.7%
0.5%
-0.1%
0.0%

GPM

#N/A
#N/A
0.0
20.0
50.0
70.0
100.0
120.0
150.0
172.0

TDH

BHP

Efficiency

30.2
29.8
28.9
28.0
25.5
22.9
17.4
11.8

#N/A
#N/A
0.5
0.6
0.7
0.8
1.0
1.1
1.2
1.3

#N/A
#N/A
11.0%
29.2%
50.2%
59.8%
66.5%
65.5%
55.2%
40.4%

#N/A
#N/A

% Error [(Data-Eq)/Data]
NPSH

-437.61%
-35.64%
0.00%
0.00%
0.00%
0.00%

As per equation
TDH (lift)

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

No
3
% Error [(Data-Eq)/Data]
TDH

-30.48%
-14.06%
-3.80%
1.61%
0.09%
-0.44%
0.94%
-0.34%
-0.65%
0.42%
% Error [(Data-Eq)/Data]
NPSH

-74.29%
-89.66%
0.00%
0.00%
0.00%
0.00%

GPM

NPSH

41.3
52.0
93.7
126.9
142.4
167.1

2.7
2.0
1.0
1.5
2.0
3.0

GPM-lift

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

TDH (lift)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

As per equation
BHP

Efficiency

-25.40%
-13.41%
-5.19%
-3.30%
-0.06%
0.21%
-0.16%
-0.37%
0.54%
-0.17%

0.0%
-107.0%
-21.2%
0.8%
0.1%
-0.6%
0.9%
0.0%
-1.0%
0.5%

TDH (lift)

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

No
4
% Error [(Data-Eq)/Data]

GPM

0.0
20.0
40.0
60.0
80.0
100.0
120.0
130.0
140.0
152.0
As per equation

TDH

BHP

Efficiency

31.3
27.4
24.9
23.3
22.0
20.3
17.6
15.8
13.4
9.9

0.5
0.5
0.6
0.7
0.7
0.8
0.9
0.9
0.9
1.0

0.6
53.4%
52.4%
55.6%
60.0%
62.6%
60.4%
56.6%
50.6%
39.8%

GPM

NPSH

41.7
50.9
92.8
125.3
132.3
138.0

0.9
0.9
1.0
1.5
1.8
2.0

GPM-lift

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

TDH (lift)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

As per equation

TDH

BHP

Efficiency

GPM

TDH

BHP

Efficiency

-4.86%
-3.59%

-42.74%
-28.51%

0.0%
22.4%

0.0
10.0

21.0
21.2

0.5
0.5

0.0
10.6%

-1.45%
-4.32%
0.10%
-0.43%
0.72%
-0.52%
-0.17%
0.31%
% Error [(Data-Eq)/Data]
NPSH

-5908.48%
-2857.90%
0.00%
0.00%
0.00%
0.00%

-21.73%
-5.73%
0.08%
-0.23%
0.10%
0.60%
-0.91%
0.34%

13.4%
-0.1%
0.0%
-0.2%
0.4%
-1.0%
1.0%
-0.3%

TDH (lift)

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

No
5
% Error [(Data-Eq)/Data]
TDH

-70.73%
-31.37%
-18.08%
-9.08%
0.00%
0.04%
-0.33%
0.74%
-1.00%
0.54%
% Error [(Data-Eq)/Data]
NPSH

-2486.07%
-1246.05%
0.00%
0.00%
0.00%
0.00%

20.0
40.0
60.0
80.0
100.0
120.0
130.0
140.0
As per equation

21.3
20.9
19.7
17.8
15.2
11.9
10.0
8.0

GPM

NPSH

28.7
46.5
89.0
120.1
125.1
131.4

30.0
14.8
1.0
1.5
1.7
2.0

0.5
0.5
0.5
0.6
0.7
0.7
0.7
0.7
GPM-lift

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

23.0%
42.1%
54.3%
59.7%
58.9%
52.4%
47.1%
40.5%
TDH (lift)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

As per equation
BHP

Efficiency

67.41%
32.77%
21.26%
12.68%
-0.05%
0.22%
-0.48%
0.31%
0.20%
-0.19%

0.0%
-188.7%
-81.2%
-35.2%
0.0%
-0.1%
-0.1%
0.5%
-1.0%
0.6%

TDH (lift)

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

GPM

0.0
20.0
30.0
40.0
60.0
80.0
100.0
110.0
120.0
125.0
As per equation

TDH

BHP

Efficiency

30.0
23.0
20.5
18.7
16.0
14.0
11.6
9.926
7.8
6.5

0.1
0.2
0.3
0.35
0.43
0.49
0.530
0.54
0.56
0.56

1.0
70.9%
62.9%
58.4%
56.4%
57.8%
55.4%
50.6%
42.2%
36.4%

GPM

NPSH

26.4
42.8
83.9
111.5
117.8
124.9

12.9
6.7
1.0
1.5
1.7
2.0

GPM-lift

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

TDH (lift)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

No
6
% Error [(Data-Eq)/Data]
TDH

64.81%
39.53%
21.79%
9.51%
0.09%
-0.28%
0.26%
-0.08%
-0.01%
0.02%
% Error [(Data-Eq)/Data]
NPSH

-226.53%
-89.06%
0.00%
0.00%
0.00%
0.00%

As per equation
BHP

Efficiency

86.73%
47.68%
25.47%
8.09%
0.39%
-0.99%
0.65%
0.05%
-0.22%
0.10%

0.0%
33.3%
9.4%
5.3%
0.0%
0.2%
-0.5%
0.5%
-0.5%
0.2%

TDH (lift)

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

No
7
% Error [(Data-Eq)/Data]
TDH

-39.06%
-14.52%
-6.92%
-4.76%
0.11%
-0.37%
0.24%
0.39%
-0.68%
0.33%
% Error [(Data-Eq)/Data]
NPSH

-344.04%
-148.52%
0.00%
0.00%

GPM

0.0
10.0
20.0
30.0
40.0
50.0
60.0
80.0
100.0
112.0
As per equation

TDH

BHP

Efficiency

5.2
8.9
11.6
13.2
14.0
14.0
13.5
11.0
7.7
5.7

0.0
0.1
0.2
0.28
0.33
0.36
0.378
0.40
0.42
0.44

-0.1
9.2%
22.6%
33.8%
42.9%
49.6%
54.1%
55.7%
46.97%
36.6%

GPM

NPSH

24.2
39.1
59.7
77.4
89.4
103.5

1.6
0.9
0.8
1.0
1.3
1.5

GPM-lift

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

TDH (lift)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

As per equation
BHP

Efficiency

-35.22%
-4.78%
0.13%
1.98%
0.12%
-0.49%
0.79%
-0.63%
0.24%
-0.03%

0.0%
-45.2%
-18.0%
-9.4%
0.0%
0.3%
-0.7%
0.9%
-0.6%
0.2%

TDH (lift)

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

GPM

TDH

BHP

Efficiency

16.4
13.6
12.6
11.7
10.9
10.0
8.9
7.7
6.0
4.0

0.3
0.3
0.3
0.26
0.27
0.29
0.301
0.31
0.32
0.32

0.3
34.9%
40.6%
45.8%
50.1%
52.6%
52.6%
49.6%
42.8%
31.5%

GPM

NPSH

GPM-lift

TDH (lift)

21.2
33.3
50.3
70.9

2.2
1.2
0.7
1.0

0.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
As per equation

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#VALUE!
#VALUE!
#VALUE!
#VALUE!

0.00%
0.00%

#DIV/0!
#DIV/0!

80.8
92.1

No
8
% Error [(Data-Eq)/Data]
TDH

Efficiency

128.81%
329.60%
74.66%
177.05%
37.95%
82.32%
13.14%
29.10%
-0.09%
0.33%
0.28%
-0.87%
-0.25%
0.52%
-0.14%
0.59%
0.34%
-0.76%
-0.15%
0.18%
% Error [(Data-Eq)/Data]

0.0%
-61.4%
-16.4%
-7.3%
0.0%
0.1%
-0.3%
0.4%
-0.2%
0.1%

-464.87%
-180.08%
0.00%
0.00%
0.00%
0.00%

#DIV/0!
#DIV/0!

#VALUE!
#VALUE!

As per equation
BHP

NPSH

1.3
1.5

GPM

BHP

Efficiency

-2.6
2.3
5.5
7.3
8.0
7.8
7.0
5.8
4.5
3.0

-0.4
-0.1
0.0
0.13
0.19
0.22
0.221
0.22
0.23
0.27

0.1
21.3%
28.7%
35.9%
42.1%
46.4%
48.0%
46.2%
40.0%
25.8%

GPM

NPSH

GPM-lift

TDH (lift)

15.4
27.5
44.5
60.8
69.3
79.9

2.8
1.4
0.7
1.0
1.3
1.5

0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
92.0
As per equation

TDH (lift)

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

No
9
% Error [(Data-Eq)/Data]

TDH

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

As per equation

TDH

BHP

Efficiency

0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%

0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%

0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%

GPM

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A

TDH

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

BHP

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Efficiency

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

0.00%
0.00%
% Error [(Data-Eq)/Data]
NPSH

0.00%
0.00%
0.00%
0.00%
0.00%
0.00%

0.00%
0.00%

0.0%
0.0%

TDH (lift)

GPM

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

No
10
% Error [(Data-Eq)/Data]
TDH

0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
% Error [(Data-Eq)/Data]
NPSH

0.00%
0.00%
0.00%
0.00%
0.00%
0.00%

#N/A
#VALUE!
#N/A
#VALUE!
As per equation
NPSH

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

#VALUE!
#VALUE!
GPM-lift

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#VALUE!
#VALUE!
TDH (lift)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

As per equation
BHP

Efficiency

0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%

0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%

TDH (lift)

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

GPM

#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
As per equation
GPM

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

TDH

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
NPSH

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

BHP

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
GPM-lift

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Efficiency

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
TDH (lift)

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

Other Conditions
0.0000E+00
0.0000E+00
0.0000E+00

120%

100%

60%

40%

20%

0%
1

Efficiency

80%

1,150

8.19

-4.70035E-07

1,150

8.00

-3.18345E-06

1,150

7.50

-1.27136E-05

1,150

7.00

5.02434E-07

1,150

6.50

-2.16332E-05

1,150

6.00

2.12554E-05

1,150

5.50

-1.53704E-05

1,150

5.00

#DIV/0!

0.00

4.06861E-05

3,500

0.00

-7.77996E-04

6.19040E-02

2.98113E+01

9.31730E-08

-3.74056E-05

9.36652E-03

3.58193E-05

-1.93320E-02

3.02232E+01

-4.18457E-08

8.01219E-06

4.35965E-03

2.60978E-03

-2.44112E-01

3.13152E+01

-1.81114E-07

4.16833E-05

8.09228E-04

-9.91769E-04

3.61611E-02

2.09730E+01

-2.44975E-07

5.62613E-05

-1.66065E-03

4.70156E-03

-4.38343E-01

3.00483E+01

8.57205E-08

-4.32162E-05

7.71688E-03

-6.21814E-03

4.34179E-01

5.20872E+00

5.76735E-07

-1.39595E-04

1.20165E-02

2.02976E-03

-1.73499E-01

1.64094E+01

-3.79630E-07

7.05952E-05

-3.03704E-03

-9.28895E-03

5.70748E-01

-2.56436E+00

2.27859E-06

-4.36265E-04

2.77731E-02

3.92649E-01

4.95209E-01

5.01604E-01

4.99573E-01

1.04279E-01

3.44947E-02

2.97492E-01

-3.67364E-01

Grab It! XP - B u ild 10

Click on the x-axis origin.

Picture: MIII8364AV.jpg
Graph X-axis
Linear
Graph Y-axis
Linear

Log(10)
Log(e)

Date
Time

Log(10)

Log(e)

Special Graph Style

Photo
Angle

x-output
Numeric
Scientific

Point-to-Point

y-output
Numeric
Scientific

Date

Date

Time
General

Time
General

Don't Format

Don't Format

Image Geometry and Calibration

Do not use previous geometry


Use previous geometry below:

X Min Coord = 100,619


X Max Coord = 380,618
Y Min Coord = 100,618
Y Max Coord = 95,428
X Min Value = 0
X Max Value = 200
Y Min Value = 0
Y Max Value = 1.5
Date Min Value = 1/1/02
Date Max Value = 12/31/02
Time Min Value = 1:00
Time Max Value = 2:00
Scale Mark Coord 1 = 100,100
Scale Mark Coord 2 = 101,101
Scale Mark Length = 1

TDH data must be converted to feet for this template!


Only blue sections are in use

Pump Data
Minimum Rated Flow

Blue sections depend on axis type

Targeted Flow Rates

Maximum Rated Flow


0.00

BEP Flow Rate


0

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
If new graph is to be digitized, insert a new graph by clicking the [Load Picture] button.
Click on [Clear Data] Button and then Proceed with new entry according to the GrabIt Instructions.
After digitizing the curve, each set of data points (matching set of BHP and THE data points) must be copied to the [GrabIt Data Filter] tab.
Follow instructions on [GrabIt Data Filter] tab for transferring data to [Input] tab.

Instructions for Digitizing Fire Pump Curves


Set the "Special Graph Style" button to "No special style". You may only digitize one TDH or BHP curve at a time!
search Competitor Database for a list of all rated flows of the pump
enter the minimum and maximum rated flows in cells C47 & D47
Enter the BEP flow rate of the curve that you will digitize.
***Note: The BEP flow rate must be changed for each curve!
(8) data points must be digitized for each TDH or BHP curve
Refer to the "Targeted Flow Rates" shown above. Make an effort to take each data point as near to the targeted flow rate as possible.
Important: Remember to check the axis scales for non-zero values!
Important: TDH data must be converted to feet for this template!
a minimum of (4) data points must be digitized for each lift or NPSH curve
In the Input tab data add a comment for the capacity cell where the lift test failed

2
4
6
8
10
11
14
15

Set 1
Point
x

2
3
6
8
9
12
14
15

2
4
6
8
10
11
14
15

Set 1

Active

Points=

0
18.4552133
35.5351119
48.3298393
68.9224604
107.896734
124.870258
136.173277
150.981422
172.792221

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Q vs Head
x
0
20
50
100
120
140
150
180

8 3/16 inch dia


y
bhp
31
0.52
31
0.62
30.899
0.78
27.8
1.05
25.1303152
1.14
22
1.23
20
1.27
13
1.41

NPSH
8 3/16 inch dia
x
y
40.6750815
0.5
Units are not important for the pick-up test
52.7161186
1.5
93.0641523
1
Pick-up Delta
Average
Pickup err.
Curves
125.570923
1.5
350
0.00%
BHP
145.332503
2
0
0.00%
Head
169.283799
3
0
0.00%
Efficiency
BHP
"Average" is the Average value at the right-end of the correspong type of curves
8 3/16 inch dia
Pick-up Delta is the absolute pick-up error at the zoom under which points are picked up.
x
y
To estimate the error sett-up the pickup zoom (if required)
Pick up a point at intersection point of curve and Y-grid line
Move the mouse to move the cursor away at try to click the same point
Repeat the pick up 5 times. Pick-up Delta = (MaxY-MinY) of all the picks

[GrabIt Data Filter] tab.

geted flow rate as possible.

29.2315879
29.1271383
29.0342925
28.643559
27.5680732
23.8232144
21.4826775
19.6547374
16.6836094
11.2655561

eff

8 inch dia
y
bhp
29
0.48
29
0.58
28.99
0.73
0.82
27.86
25.5
0.9756
23 1.05920141
17.2790011 1.18673367
11.8
1.27

x
0.00001
20
50
70
100
120
150
172

8 inch dia
x
y
41.3239066
51.9516059
93.7029188
126.908814
142.420322
167.070743

0.5
1.5
1
1.5
2
3

8 inch dia
x

eff

Set 1
Points=

Set 2
9 Points=
y
x
0.00
48.19
48.91
17.85
46.80
40.57
41.88
57.60
36.94
78.88
30.12
100.13
21.42
119.96
12.70
139.77
6.93
159.56
180.75

x
0.00
20.31
41.59
60.01
81.27
101.09
119.48
140.70
150.59

Set 1
Points=
x

Set 2
Points=

10
y

Set 3
10 Points=
y
x
90.70
0.00
91.45
18.07
91.21
37.95
90.09
57.82
87.03
77.68
81.14
98.94
75.27
118.78
67.50
138.60
56.90
157.01
44.40
179.63
197.99

Set 3
Points=

10
y

0.00
0.07
20.08
38.69
60.12
80.14
98.73
120.15
140.16
153.02

0.94
0.94
1.04
1.46
1.41
1.67
1.78
1.72
1.83
1.79

0.00
20.19
40.21
60.24
80.28
100.30
120.34
140.35
161.81
183.26

2.03
2.29
2.55
2.81
3.23
3.49
3.91
4.01
4.27
4.53

Q
0.00
20.31
41.59
60.01
81.27
101.09
119.48
140.70
150.59

BHP
0.94
0.94
1.04
1.46
1.41
1.67
1.78
1.72
1.83

H
48.19
48.91
46.80
41.88
36.94
30.12
21.42
12.70
6.93

0.00
26.77
47.18
43.39
53.84
46.07
36.36
26.19
14.41

0.00
20.26
40.28
60.35
80.37
98.98
120.44
139.04
159.07
179.10
200.57

11
y
116.22
116.01
115.80
114.65
112.55
107.61
102.68
95.86
89.05
78.42
66.89

Active
11
y

2.50
3.07
3.33
4.06
4.32
4.74
5.00
5.27
5.68
5.95
6.36

Q vs Head
7.5inch dia
y
bhp
24
0.4
24
0.47
24
0.56
23.7
0.64
22
0.73992
20.2
0.82
17.8
0.88457
15.7
0.91
13.319
0.94
9.9
0.95

x
0.00001
20
40
60
80
100
120
130
140
152

eff

7 inch data
x
y
bhp
0.0001
20
0.35
10
20.5
0.38
20
21
0.4
40
20
0.48
60
19.7
0.55
80
17.7
0.6
100 15.2838 0.65182
120 11.838 0.69128
130
10
0.69
140
8
0.7

eff

x
0.00001
20
30
40
60
80
100
110
120
125

6.5 inch data


y
bhp
17.6
0.32
17.5
0.36
17.4
0.38
17.1
0.4
16
0.43
14
0.49
11.5586835 0.52698
10 0.546
7.6905 0.55721
6.5
0.56

7.5inch dia
x
y
41.68933648
0.5
50.93335038
0.5
92.79226645
1
125.3159915
1.5
132.3490371
1.75
137.996748
2

7 inch data
x
y
28.727448
0.5
46.4810198
0.5
89.0288058
1
120.129207
1.5
125.057657 1.75
131.41703
2

6.5 inch data


x
y
26.4480935
42.7783407
83.9104009
111.460087
117.81946
124.867701

7.5inch dia
x

7 inch data
x

6.5 inch data


x
y

0.5
0.5
1
1.5
1.75
2

6 inch data
eff

x
0.00001
10
20
30
40
50
60
80
100
112

y
14.8
14.8
14.8
14.6
14
13.99
13.5
11.02096
7.7
5.7

6 inch data
x
24.17634
39.09086
59.66828
77.38387
89.41374
103.533
6 inch data
x

6 inch data
bhp

eff
0.26
0.27
0.3
0.31

0.33
0.35493
0.38
0.397901822
0.416
0.44

y
0.5
0.5
0.75
1
1.25
1.5

x
0.00001
20
30
40
50
60
70
80
90
100

5.5 inch data


y
bhp
11.8
0.22
11.9
0.25
11.8
0.26
11.2
0.27
10.9
0.275
9.95
0.286
8.96
0.303
7.68
0.31
5.99
0.32
4
0.32

eff

5 inch data
y
eff

5.5 inch data


x
y
21.19291
0.5
33.27598
0.5
0.75
50.3027
1
70.86493
80.75222 1.25
92.07803 1.5

5 inch data
x
y
15.35524
27.45351
44.48782
60.80287
69.29723
79.91898

5.5 inch data


x
y

5 inch data
x
y

bhp

eff

bhp

x
0.5
0.5
0.75
1
1.25
1.5

eff

bhp

eff

bhp

Instructions:
Copy GPM-TDH data points from the [GrabIt] tab and paste values into cells B11:C20. The last row of data must be in row 20!
Copy GPM-BHP data points from the [GrabIt] tab and paste values into cells E11:F20. The last row of data must be in row 20!
Copy the yellow table and paste into the [Input] tab.
***NOTE: The BHP data coefficient check on the [Curves] tab will not work for the BHP data points, so accuracy of curve fit
should be checked before copying to the [Input] tab.

Data Point

GPM

TDH (feet)

GPM

BHP

1
2
3
4
5
6
7
8
9
10

0
16.133397
28.259554
43.93
55.32
62.44
66.71
73.10
82.33
90.14

8.79877198
8.86657761
8.48152226
7.60
6.74
6.22
5.88
5.04
3.87
2.71

0
12.2003598
20.74591869
31.43
40.69
49.95
60.64
72.03
80.57
92.68

0.17273226
0.17063596
0.17700767
0.18300943
0.20
0.21
0.23
0.23
0.24
0.25

Copy & Paste this data to the [Input] tab


Data Point

GPM

TDH (feet)

BHP

1
2
3
4
5
6
7
8
9
10

0
16.133397
28.259554
43.9337709
55.3227656
62.4418438
66.7117602
73.101329
82.3324066
90.1350765

8.79877198
8.86657761
8.48152226
7.59755464
6.73661262
6.21851224
5.8756704
5.04159187
3.87234679
2.71077705

-0.01
0.11
0.16
0.20
0.22
0.23
0.23
0.23
0.24
0.25

2.7057E-05

-7.2551E-03

5.0227E-01

-3.4262E+00

The last row of data must be in row 20!


he last row of data must be in row 20!

data points, so accuracy of curve fit

BHP Coeff. Check


0
%BHP

-1969.42%
105.21%
35.88%
6.17%
0.21%
-0.61%
0.65%
-0.22%
-0.08%
0.05%

0
0
BHP

BHP

-0.01
0.08
0.13
0.17
0.20
0.21
0.22
0.23
0.24
0.25

0
0
0
0
0

20

40

Test Data BHP

5.5648E-07

-1.1760E-04

8.9250E-03

-9.2399E-03

BHP Coeff. Check

60
GPM
Test Data BHP

Curve Fit Check

80

100

Instructions; Copy&past the Test Report as shown below or enter data from curves .
Print/Enter data at nominal RPM and Head in feet !!
Leave four empty lines on the top of each record:
To insert new data insert 30 empty rows in Log and Test tabs . Then copy&paste tables and graphs in L
Test No

Owner
Date:

( Competitor-Name, AP-Published, AP-H2O, AP-Test, AP-R&D )

Serial No:

Descript.
Customer
Pump Size
Pump Model
Disch/Suc. ID
Impeller Dia.

TDH must be entered in feet !


Do not use these coefficients for the CAP template !

0.000

Filing Tip Work


Stages

OK!
1

Data Point

1
2
3
4
5
6
7
8

GPM

352.99
678.88
972.83
1181.82
1523.72
1785.21
2094.42
2431.68

TDH (feet)

925.64
914.09
874.09
846.95
781.32
714.87
634.74
510.84

BHP

296.08
342.01
371.14
387.91
414.53
425.56
434.09
432.83

( 100 x % )
Efficiency
#DIV/0!

#DIV/0!
27.87
45.82
57.86
65.16
72.52
75.73
77.34
72.47

OK!
BEP Capacity Error is larger than 2% ! Consider points redo !
OK!

Equation Fit Coefficients

RPM

2950
2950
2950
2950
2950
2950
2950
2950

BHP

-6.027E-09

-8.536E-06

1.272E-01

TDH

-1.235E-08

-2.435E-05

-5.233E-02

Eff.

-3.198E-09

-2.443E-06

4.777E-02

x1=

-2.500E+03

BEP

RPM
2950

x2=

GPM

TDH (feet)

1991.1

662.5

OK!
Warning: Calculated Best Efficiency < Tabular Best Efficienc

DO NOT CUT CELLS IN THIS TAB !


COPY, COPY &PASTE ARE OK !

Manualy enter NPSH and/or Lift data in shaded cells

Optional Inputs

&paste tables and graphs in Log tab


P_barom.: 34.3

NPSH

gauge_h

Not Linked Values


Head -Psi

Head - ft

Data Point

0.00
0.00
0.00
0.00
0.00
0.00
0.00

or the CAP template !

GPM

NPSH

RPM

0.5

Not Used in This Template


Nominal Values
GPM (Nom)
NPSH

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Speed at NPSH Test is not equal to the nominal curve speed!


Speed at NPSH Test is not equal to the nominal curve speed!

n 2% ! Consider points redo !

Lift test No

Enter the last 6 points without velocity correction !


Nominal Values

it Coefficients

gpm

C heck-up !

% Error

2.606E+02

2094

434.2

0.02%

9.607E+02

2094

630.8

-0.62%

1.689E+01

2094

76.8

-0.65%

BEP Efficiency Error :

-0.35%

BEP Capacity Error :

-5.19%

Max error:

5.19%

1.991E+03

BHP

% Eff.

432.4

77.1

iency < Tabular Best Efficiency !

Data Point

GPM

TDH

RPM

GPM (Nom) TDH (Nom))

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Not Used in This Template


Nominal Values
P_barom
RPM(Nom)

2950
2950
2950
2950
2950
2950

velocity correction !
RPM(Nom)

2950
2950
2950
2950
2950
2950

Gage_h

34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
34.30
0.50
not used
in this template

You might also like